Drawing Part-9.pdf
PDF 2 MB Posted
- Solicitation number
- 36C24921B0013
About this file
This document provides details for a federal contract solicitation to install historic site enhancements at the James H. Quillen VA Medical Center in Mountain Home, Tennessee. The solicitation is a 100% set-aside for Service-Disabled Veteran Owned Small Businesses, with a bid submission deadline of February 1, 2022 and anticipated award date not provided. The scope of work includes furnishing all labor, materials and equipment to complete installation of signs and historical site enhancements in accordance with drawings and specifications. Specific tasks involve project management, planning and coordination, site visits, deliveries, submittals, inspections and training. The period of performance is 180 calendar days from notice to proceed.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24921B0013 0006.pdf | ||
| 36C24921B0013 0005.pdf | ||
| 36C24921B0013 0004.pdf | ||
| Specification 073126.pdf | ||
| 36C24921B0013 0003.pdf | ||
| 32 18 27 -02792-PLAYGROUND SURFACING - POURED RUBBER.pdf | ||
| 36C24921B0013 0002.pdf | ||
| 36C24921B0013 0001.pdf | ||
| Specifications.pdf | ||
| Drawing Part-5.pdf | ||
| Drawing Part-7.pdf | ||
| Drawing Part-4.pdf | ||
| Drawing Part-11.pdf | ||
| Drawing Part-1.pdf | ||
| 36C24921B0013_3.docx | DOCX document | |
| RFI Form - Install Historic Site Enhancements.pdf | ||
| Drawing Part-6.pdf | ||
| Drawing Part-8.pdf | ||
| Drawing Part-12.pdf | ||
| Drawing Part-10.pdf | ||
| WD 20220191 9-2-2022.pdf | ||
| Contractor EMR Certification Form.pdf | ||
| Drawing Part-3.pdf | ||
| Drawing Part-2.pdf | ||
| Header - List of Attachments.txt | TXT text file | |
| Drawing Part-13.pdf |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
James H. Quillen VA Medical Center
Mountain Home, TN
10"x30"x3" STACKED MANUFACTURED
STONE VENEER, REFER TO
SPECIFICATION 047200 FOR MORE
INFORMATION
FINISHED GRADE
REMOVABLE 0.125" THICK
ALUMINUM FACE, CHARCOAL
GREY W/ SATIN FINISH
3/8" MORTAR JOINT, RAKED
U.S. Department of Veterans Affairs INTERNAL WHITE LED
ILLUMINATION W/ 120v - 277v
POWER PACK
16" O.A. DEEP EXTRUDED
ALUMINUM ALLOY CABINET,
75% RECYCLED EXTRUDED
ALUMINUM FRAME
ROUTED ALUMINUM FACE W/
WHITE TRANSLUCENT
ACRYLIC BACKED COPY
2" ALUMINUM REVEAL, PAINTED
BLACK W/ SATIN FINISH
FULL COLOR LED ELECTRONIC
MESSAGE UNIT W/ CELLULAR DATA
CONNECTION, REFER TO
SPECIFICATION 101410 AND DIVISION
26 ELECTRICAL SPECIFICATIONS
EXISTING MASONRY PILLAR TO
REMAIN (TYP. 2), REFER TO
ARCHITECTURAL DRAWINGS
FOR MORE INFORMATION
REFER TO ARCHITECTURAL
AND STRUCTURAL DRAWINGS
FOR INFORMATION
REGARDING BELOW GRADE
CONCRETE FOOTING
CAST STONE CAP, REFER TO
SPECIFICATION 047200 FOR
MORE INFORMATION
REFER TO ARCHITECTURAL
AND STRUCTURAL DRAWINGS
FOR INFORMATION
REGARDING BELOW GRADE
CONCRETE FOOTING
8" CMU W/ FULLY GROUTED
CELLS
CAST STONE CAP, REFER TO
SPECIFICATION 047200 FOR
MORE INFORMATION
EXISTING MASONRY PILLAR
TO REMAIN (TYP. 2), REFER
TO ARCHITECTURAL
DRAWINGS FOR MORE
INFORMATION
GALV. STEEL TIES, 24" O.C.
EACH WAY, STAGGERED
STONE TO EXTEND 8" BELOW
GRADE (MIN.)
CMU BLOCK MASONRY SIGN
BASE W/ 10"x30"x3" CAST
MANUFACTURED STONE
VENEER
3/8" MORTAR JOINT, RAKED
1/2"Ø x 6" S.S. DOWEL, TYP.
NOTE: 2 DOWELS ON EACH END OF
PRECAST SECTION, 4 TOTAL PER
SECTION, 8 TOTAL PER SIGN
Building162 Community Living Center
FINISHED GRADE
CMU BLOCK MASONRY BASE
W/ MANUFACTURED STONE
VENEER, REFER TO
SPECIFICATION 047301
4" CAST STONE CAP ON TOP
OF MASONRY BASE
2" ALUM. REVEAL. PAINTED
BLACK W/ SATIN FINISH
12" O.A. DEEP EXTRUDED
ALUMINUM ALLOY CABINET,
75% RECYCLED EXTRUDED
ALUMINUM FRAME
ROUTED ALUM. FACE W/
WHITE TRANSLUCENT
ACRYLIC BACKED COPY
LIGHT GREY PAINTED FACE
RETAINER MOLDING AND
CABINET RETURN W/ SATIN
FINISH
REMOVABLE 0.125" THICK
ALUM. FACE, CHARCOAL
GREY W/ SATIN FINISH
REFER TO ARCHITECTURAL
AND STRUCTURAL DRAWINGS
FOR INFORMATION
REGARDING BELOW GRADE
CONCRETE FOOTING
8" CMU W/ FULLY GROUTED
CELLS
CAST STONE CAP
REFER TO SPECIFICATION
047301 FOR MANUFACTURED
STONE VENEER
GALV. STEEL TIES, 24" O.C.
EACH WAY, STAGGERED
REFER TO ARCHITECTURAL
AND STRUCTURAL DRAWINGS
FOR INFORMATION
REGARDING BELOW GRADE
CONCRETE FOOTING
MANUFACTURED STONE
VENEER TO EXTEND 8"
BELOW GRADE (MIN.)
CONC. COLLAR, TYP. ALL SIDE
OF SIGN
CONCRETE COLLAR, TYP. ALL
SIDES OF SIGN
3/8" MORTAR JOINT, RAKED
NOTE: 2 DOWELS ON EACH END OF
PRECAST SECTION, 4 TOTAL PER
SECTION, 8 TOTAL PER SIGN
1/2"Ø x 6" S.S. DOWEL, TYP.
2" ALUM. REVEAL. PAINTED
BLACK W/ SATIN FINISH
3 1/4" DEEP 75% RECYCLED
EXTRUDED ALUM. SIGN CABINET,
.08" THICK REMOVABLE ALUM.
FACES (SLIDE OUT FACES) PAINTED
FACES CHARCOAL GREY W/ SATIN
FINISH
6" H. CHANGEABLE WORD BAR,
PAINTED CHARCOAL GREY W/ SATIN
FINISH, WHITE VINYL LETTERS
APPLIED TO A FACE
REFLECTIVE WHITE VINYL LETTERS
& GRAPHICS APPLIED TO FACES
3 1/4" DIA. FULL ROUND ALUM. POLE,
PAINTED BLACK W/ SATIN FINISH,
KEY SLOT TRACK FOR SIGN
CABINET W/ FILLER
PAINTED FACES RETAINER
MOLDING & RETURN LIGHT GREY W/
SATIN FINISH
EXTEND FOOTING 4" ABOVE
GROUND WITH 3/4" CHAMFER ON
ALL EDGES
Facilities Management
Building
3,000 PSI MIN. CONCRETE
FOOTING
U.S. Department of Veterans Affairs
Information Center
FINISHED GRADE
CMU BLOCK MASONRY BASE
W/ MANUFACTURED STONE
VENEER, REFER TO
SPECIFICATION 047301
4" THICK CAST STONE CAP ON
TOP OF MASONRY BASE
2" ALUM. REVEAL. PAINTED
BLACK W/ SATIN FINISH
12" O.A. DEEP EXTRUDED
ALUMINUM ALLOY CABINET,
75% RECYCLED EXTRUDED
ALUMINUM FRAME
ROUTED ALUM. FACE W/ WHITE
TRANSLUCENT ACRYLIC BACKED
COPY. GRAPHIC FOR
INFORMATION SIGN TO BE
PROVIDED BY COR
LIGHT GREY PAINTED FACE
RETAINER MOLDING AND
CABINET RETURN W/ SATIN
FINISH
REMOVABLE 0.125" THICK
ALUM. FACE, CHARCOAL
GREY W/ SATIN FINISH
REFER TO ARCHITECTURAL
AND STRUCTURAL DRAWINGS
FOR INFORMATION
REGARDING BELOW GRADE
CONCRETE FOOTING
CONCRETE COLLAR, TYP. ALL
SIDES OF SIGN
REFER TO ARCHITECTURAL
AND STRUCTURAL DRAWINGS
FOR INFORMATION
REGARDING BELOW GRADE
CONCRETE FOOTING
8" CMU W/ FULLY GROUTED
CELLS
CAST STONE CAP
REFER TO SPECIFICATION
047301 FOR MANUFACTURED
STONE VENEER
GALV. STEEL TIES, 24" O.C.
EACH WAY, STAGGERED
MANUFACTURED STONE
VENEER TO EXTEND 8"
BELOW GRADE (MIN.)
CONC. COLLAR, TYP. ALL SIDE
OF SIGN
NOTES:
1. 2 DOWELS ON EACH END OF
PRECAST SECTION, 4 TOTAL PER
SECTION, 8 TOTAL PER SIGN.
2. GRAPHIC FOR INFORMATION SIGN TO
BE PROVIDED BY COR.
1/2"Ø x 6" S.S. DOWEL, TYP.
2" ALUM. REVEAL. PAINTED
BLACK W/ SATIN FINISH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER
321 4 5 6 7 8 9 10
06/25/2021 BAC IPBRevisions: Date:
AE INSTALL SIGNS & HISTORICAL
SITE ENHANCE
#621-20-104
MT. HOME, TENNESSEE
CONSTRUCTION
BID DOCUMENTS SITE
JAMES H.
QUILLEN VA
MEDICAL
CENTER
95% REVIEW 06/08/2021
LAN
DSCAPE ARCHITEC
T
Lic. No. 01972
IAN P. BUCHANANCO
M M
ONWEALTH OF VIRGIN
IA
A PRIMARY MONUMENT SIGN (ILLUMINATED)
SCALE: 3/4" = 1'-0"
NOTES:
1. SIGN BASE SHALL BE STACKED MANUFACTURED STONE VENEER:
CASE MANUFACTURED STONE VENEER. REFER TO SPECIFICATION
047200 FOR MORE INFORMATION
2. BASE CAPSTONE MATERIAL SHALL BE CAST STONE. REFER TO
SPECIFICATION 047200 FOR MORE INFORMATION.
3. REFER TO SPECIFICATION 101410 FOR MORE INFORMATION
REGARDING SIGN MATERIALS AND INSTALLATION.
4. LED DIGITAL SHALL BE PROVIDED AS SHOWN AND PER SPECIFICATION
101410.
5. PRIMARY MONUMENT SIGNS ARE TO BE CUSTOM DESIGNED TO FIT
AND BE INSTALLED BETWEEN EXISTING ORNATE MASONRY PILLARS.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING SHOP DRAWINGS TO
BE APPROVED BY COR.
6. REFER TO ARCHITECTURAL DRAWINGS FOR INFORMATION
REGARDING BELOW GRADE CONCRETE FOOTING AND EXISTING
MASONRY PILLARS.
7. REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL WIRING FOR
SIGN.
C PRIMARY BUILDING ID SIGN
SCALE: 3/4" = 1'-0"
CAMPUS SIGNAGE DETAILS
L503
B SECONDARY BUILDING ID SIGN: POST-MOUNTED
SCALE: 3/4" = 1'-0"
D INFORMATION CENTER SIGN
SCALE: 3/4" = 1'-0"
CMU BLOCK MASONRY BASE
W/ MANUFACTURED STONE
VENEER, REFER TO
SPECIFICATION 047301
FINISHED GRADE
3/8" MORTAR JOINT, RAKED
REMOVABLE 0.125" THICK
ALUM. FACE, CHARCOAL
GREY W/ SATIN FINISH
12" O.A. DEEP EXTRUDED
ALUMINUM ALLOY CABINET,
75% RECYCLED EXTRUDED
ALUMINUM FRAME
LIGHT GREY PAINTED FACE
RETAINER MOLDING AND
CABINET RETURN W/ SATIN
FINISH
2" ALUM. REVEAL. PAINTED
BLACK W/ SATIN FINISH
4" THICK CAST STONE CAP
ON TOP OF MASONRY BASE
REFER TO ARCHITECTURAL
AND STRUCTURAL DRAWINGS
FOR INFORMATION
REGARDING BELOW GRADE
CONCRETE FOOTING
U.S. Department of Veterans Affairs
Emergency Department Emergency Department
Patient & Visitor Parking
REFER TO ARCHITECTURAL
AND STRUCTURAL DRAWINGS
FOR INFORMATION
REGARDING BELOW GRADE
CONCRETE FOOTING
8" CMU W/ FULLY GROUTED
CELLS
CAST STONE CAP
REFER TO SPECIFICATION
047301 FOR MANUFACTURED
STONE VENEER
GALV. STEEL TIES, 24" O.C.
EACH WAY, STAGGERED
MANUFACTURED STONE
VENEER TO EXTEND 8"
BELOW GRADE (MIN.)
CONC. COLLAR, TYP. ALL SIDE
OF SIGN
CONCRETE COLLAR, TYP. ALL
SIDES OF SIGN
1/2"Ø x 6" S.S. DOWEL, TYP.
NOTE: 2 DOWELS ON EACH END OF
PRECAST SECTION, 4 TOTAL PER
SECTION, 8 TOTAL PER SIGN
2" ALUM. REVEAL. PAINTED
BLACK W/ SATIN FINISH
PAINTED FACES RETAINER
MOLDING & RETURN LIGHT GREY
W/ LIGHT FINISH
3 1/4" DIA. FULL ROUND ALUM.
POLE, PAINTED BLACK W/ SATIN
FINISH, KEY SLOT TRACK FOR
SIGN CABINET W/ FILLER
3 1/4" DEEP 75% RECYCLED
EXTRUDED ALUM. SIGN CABINET, .08"
REMOVABLE ALUM. FACES (SLIDE OUT
FACES) PAINTED FACES CHARCOAL
GREY W/ SATIN FINISH
REFLECTIVE WHITE VINYL
LETTERS & GRAPHICS APPLIED
TO FACES
APPROX. 4" ABOVE GROUND
CONCRETE PAD W/ BEVELED
EDGES
Community Living Center Mental Health Clinic South Entrance
Main Entrance (Second St)
3,000 PSI MIN. CONCRETE
FOOTING
3 1/4" DEEP 75% RECYCLED EXTRUDED
ALUM. SIGN CABINET, 0.08" REMOVABLE
ALUM. FACES (SLIDE OUT FACES) PAINTED
FACES CHARCOAL GREY W/ SATIN FINISH
3 1/4" DIA. FULL ROUND ALUM.
POLE, PAINTED BLACK W/ SATIN
FINISH, KEY SLOT TRACK FOR SIGN
CABINET W/ FILLER
REFLECTIVE WHITE VINYL LETTERS &
GRAPHICS APPLIED TO FACES
PAINTED FACE RETAINER MOLDING
& RETURN LIGHT GREY W/ SATIN
FINISH
APPROX. 4" ABOVE GROUND
CONCRETE PAD W/ BEVELED
EDGES
Exit to Sidney St.
Additional Patient & Visitor Parking (Shuttle Service)
3,000 PSI MIN. CONCRETE
FOOTING
3 1/4" DEEP 75% RECYCLED
EXTRUDED ALUM. SIGN CABINET,
.08" THICK REMOVABLE ALUM.
FACES (SLIDE OUT FACES) PAINTED
FACES CHARCOAL GREY W/ SATIN
FINISH
6" H. CHANGEABLE WORD BAR,
PAINTED CHARCOAL GREY W/ SATIN
FINISH, WHITE VINYL LETTERS
APPLIED TO A FACE
REFLECTIVE WHITE VINYL LETTERS
& GRAPHICS APPLIED TO FACES
3 1/4" DIA. FULL ROUND ALUM. POLE,
PAINTED BLACK W/ SATIN FINISH,
KEY SLOT TRACK FOR SIGN
CABINET W/ FILLER
PAINTED FACES RETAINER
MOLDING & RETURN LIGHT GREY W/
SATIN FINISH
APPROX. 4" ABOVE GROUND
CONCRETE PAD W/ BEVELED
EDGES
Staff/Faculty Parking
Parking
B
3,000 PSI MIN. CONCRETE
FOOTING
U.S. Department of Veterans Affairs
CMU BLOCK MASONRY BASE
W/ MANUFACTURED STONE
VENEER, REFER TO
SPECIFICATION 047301
FINISHED GRADE
REMOVABLE 0.125" THICK
ALUM. FACE, CHARCOAL
GREY W/ SATIN FINISH
3/8" MORTAR JOINT, RAKED
16" O.A. DEEP EXTRUDED
ALUMINUM ALLOY CABINET,
75% RECYCLED EXTRUDED
ALUMINUM FRAME
ROUTED ALUM. FACE W/
WHITE TRANSLUCENT
ACRYLIC BACKED COPY
LIGHT GREY PAINTED FACE
RETAINER MOLDING AND
CABINET RETURN W/ SATIN
FINISH
REFER TO ARCHITECTURAL
AND STRUCTURAL DRAWINGS
FOR INFORMATION
REGARDING BELOW GRADE
CONCRETE FOOTING
CAST STONE CAP
2" ALUM. REVEAL. PAINTED
BLACK W/ SATIN FINISH
CONCRETE COLLAR, TYP. ALL
SIDES OF SIGN
REFER TO ARCHITECTURAL
AND STRUCTURAL DRAWINGS
FOR INFORMATION
REGARDING BELOW GRADE
CONCRETE FOOTING
8" CMU W/ FULLY GROUTED
CELLS
CAST STONE CAP
REFER TO SPECIFICATION
047301 FOR MANUFACTURED
STONE VENEER
GALV. STEEL TIES, 24" O.C.
EACH WAY, STAGGERED
MANUFACTURED STONE
VENEER TO EXTEND 8"
BELOW GRADE (MIN.)
CONC. COLLAR, TYP. ALL SIDE
OF SIGN
1/2"Ø x 6" S.S. DOWEL, TYP.
NOTE: 2 DOWELS ON EACH END OF
PRECAST SECTION, 4 TOTAL PER
SECTION, 8 TOTAL PER SIGN
2" ALUM. REVEAL. PAINTED
BLACK W/ SATIN FINISH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER
321 4 5 6 7 8 9 10
06/25/2021 BAC IPBRevisions: Date:
AE INSTALL SIGNS & HISTORICAL
SITE ENHANCE
#621-20-104
MT. HOME, TENNESSEE
CONSTRUCTION
BID DOCUMENTS SITE
JAMES H.
QUILLEN VA
MEDICAL
CENTER
95% REVIEW 06/08/2021
LAN
DSCAPE ARCHITEC
T
Lic. No. 01972
IAN P. BUCHANANCO
M M
ONWEALTH OF VIRGIN
IA
L504
B SECONDARY DIRECTIONAL SIGN
SCALE: 3/4" = 1'-0"
D QUATERNARY DIRECTIONAL SIGNC TERTIARY DIRECTIONAL SIGN E PARKING ID SIGN
SCALE: 3/4" = 1'-0"SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0"
CAMPUS SIGNAGE DETAILS
A PRIMARY DIRECTIONAL SIGN
1/8" THICK ALUMINUM
SIGN PANELS' COLOR
TO BE WHITE;
PROVIDE SHOP
DRAWINGSAMBULANCE
ENTRANCE NOTE: SIGN SIZE, TEXT, ARROWS,
GRAPHICS, COLORS, ETC., SHALL
BE FABRICATED AS INDICATED IN
EI-08.01 OF THE VA SIGNAGE
DESIGN MANUAL
1/8" THICK ALUMINUM
SIGN PANELS' COLOR
TO BE CHARCOAL;
PROVIDE SHOP
DRAWINGS
Building
NOTE: SIGN SIZE, TEXT, ARROWS,
GRAPHICS, COLORS, ETC., SHALL
BE FABRICATED AS INDICATED IN
EN-06.06 (MESSAGE LAYOUT A) OF
THE VA SIGNAGE DESIGN MANUAL
1/8" THICK ALUMINUM
SIGN PANELS' COLOR
TO BE CHARCOAL;
PROVIDE SHOP
DRAWINGS
Building
Admissions Outpatient Rehabilitation
Dental Clinic
NOTE: SIGN SIZE, TEXT, ARROWS,
GRAPHICS, COLORS, ETC., SHALL
BE FABRICATED AS INDICATED IN
EN-06.03 (MESSAGE LAYOUT B) OF
THE VA SIGNAGE DESIGN MANUAL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER
321 4 5 6 7 8 9 10
06/25/2021 BAC IPBRevisions: Date:
AE INSTALL SIGNS & HISTORICAL
SITE ENHANCE
#621-20-104
MT. HOME, TENNESSEE
CONSTRUCTION
BID DOCUMENTS SITE
JAMES H.
QUILLEN VA
MEDICAL
CENTER
95% REVIEW 06/08/2021
LAN
DSCAPE ARCHITEC
T
Lic. No. 01972
IAN P. BUCHANANCO
M M
ONWEALTH OF VIRGIN
IA
L505
CAMPUS SIGNAGE DETAILS
A AMBULANCE ENTRANCE SIGN
SCALE: 3/4" = 1'-0" B
BUILDING ID SIGN:
BUILDING-MOUNTED PRIMARY
SCALE: 3/4" = 1'-0" C
BUILDING ID SIGN:
BUILDING-MOUNTED SECONDARY
.125" THICK ALUM. PANEL,
PAINTED CHARCOAL
GREY FACE & LIGHT GREY
BORDER W/ SATIN FINISH
REFLECTIVE WHITE VINYL
LETTERS & GRAPHICS
APPLIED TO FACES
3" DIA. ROUND ALUM.
POLE WITH CAP, BLACK
POWDER COATED FINISH,
KEY SLOT TRACK FOR
SIGN CABINET W/ FILLERNOTE
1. THIS POST AND SIGN DETAIL SHALL
APPLY FOR ALL POST AND SIGN
REPLACEMENTS INDICATED AS
"VEHICULAR POST TYPE 2" IN THE
"POST IMPROVEMENT / TYPE"
CATEGORY ON SHEETS L111-L114
2. REFER TO SPECIFICATION 101400
FOR POST AND SIGN INFORMATION.
3,000 PSI CONCRETE
FOOTING
TOP OF CONCRETE
FOOTING LOCATED 6in
BELOW FINISH GRADE.
SLOPE TOP FOR
DRAINAGE, TYP.
INSTALLATION IN
LAWN
INSTALLATION IN
PAVED AREAS
PAVEMENT SURFACE ABOVE
FOOTING, SURFACE MATERIAL
AND DEPTH VARIES, SEE
PLANS
SLOPE SLOPE
POST CAP
STAINLESS STEEL
MACHINE SCREWS
THROUGH SIGN AND POST
EXTEND FOOTING 4" ABOVE
GROUND AND SLOPE EDGES
AWAY FROM POST.
1" LIGHT GREY BORDER
AROUND ALUM. SIGN
.125" THICK ALUM. PANEL
2.5" SQUARE
PERFORATED STEEL
POST, PAINTED W/ BLACK
ENAMEL , REFER TO
SPECIFICATION 101400
FOR MORE INFORMATIONNOTE
1. THIS POST AND SIGN DETAIL SHALL
APPLY FOR ALL POST AND SIGN
REPLACEMENTS INDICATED AS
"VEHICULAR POST TYPE 3" IN THE
"POST IMPROVEMENT / TYPE"
CATEGORY ON SHEETS L111-L114
2. POST TO BE DRIVEN INTO GRADE
(DEPTH PER MANUFACTURER
RECOMMENDATION).
3. REFER TO SPECIFICATION 101400 FOR
POST AND SIGN INFORMATION.
STAINLESS STEEL
MACHINE SCREWS
THROUGH SIGN AND POST
ACCESSIBLE
VAN
RESERVED
PARKING
NO
PARKING
NO
PARKING
FIRE
LANE
NO
PARKING
NO
PARKING
NO
PARKING
NO
PARKING
SIDE
OF STREET
THIS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER
321 4 5 6 7 8 9 10
06/25/2021 BAC IPBRevisions: Date:
AE INSTALL SIGNS & HISTORICAL
SITE ENHANCE
#621-20-104
MT. HOME, TENNESSEE
CONSTRUCTION
BID DOCUMENTS SITE
JAMES H.
QUILLEN VA
MEDICAL
CENTER
95% REVIEW 06/08/2021
LAN
DSCAPE ARCHITEC
T
Lic. No. 01972
IAN P. BUCHANANCO
M M
ONWEALTH OF VIRGIN
IA
A VEHICULAR POST TYPE 1
L506
SCALE: 3/4" = 1'-0"
CAMPUS SIGNAGE DETAILS
B VEHICULAR POST TYPE 2
SCALE: 3/4" = 1'-0"
NOTE
1. THIS POST AND SIGN DETAIL SHALL
APPLY FOR ALL POST AND SIGN
REPLACEMENTS INDICATED AS
"VEHICULAR POST TYPE 1" IN THE "POST
IMPROVEMENT / TYPE" CATEGORY ON
SHEETS L111-L114.
2. IMAGE SHOWN IS AN EXAMPLE OF
ORNAMENTAL POST AND SIGN EXISTING
ON THE CAMPUS. PROPOSED POSTS
AND SIGNS SHALL MATCH EXISTING
POST AND SIGNS AS MANUFACTURED BY
"FAST SIGNS"
FASTSIGNS INTERNATIONAL, INC.
2708 N. ROAN ST.
JOHNSON CITY, TN 37601
C VEHICULAR POST TYPE 3
SCALE: 3/4" = 1'-0" D TRAFFIC REGULATORY SIGNS
SCALE: NTS
D STANDARD PARKING SIGNS
SCALE: 3/4" = 1'-0" E GRAPHIC SYMBOLS
SCALE: NTS
NOTE: GRAPHIC SYMBOLS SHOWN ARE
USED FOR GRAPHIC REPRESENTATION
ONLY. CONTRACTOR SHALL SUBMIT SHOP
DRAWINGS SHOWING SIZE AND
DIMENSIONING OF ALL SYMBOLS TO BE
USED FOR REVIEW AND APPROVAL BY COR
AND LANDSCAPE ARCHITECT.
POSITION 1B
PARALLEL TO SIDEWALK
POSITION 1A
PERPENDICULAR TO SIDEWALK
CONCRETE SIDEWALK OR
ASPHALT PATH (WIDTH
VARIES)
LAWN
VEHICULAR POST TYPE 2
OR 3, SEE DETAIL AND
SHEETS L111-L114 FOR
POST AND SIGN TYPE
DRIVE AISLE, EDGE OF
PAVEMENT OR CURB AND
GUTTER.
VEHILCUAR POST TYPE 2 OR 3,
SEE DETAIL AND SHEETS
L111-L114 FOR POST AND SIGN
TYPE
EP OR EDGE OF CURB
NOTE:
1. DIMENSION IS FROM CENTER OF POST TO EITHER
THE BACK OF CURB OR THE EDGE OF PAVEMENT
POSITION 2B
PARALLEL TO PARKING SPACE
POSITION 2A
ANGLED TO PARKING SPACE
CONCRETE SIDEWALK OR
ASPHALT PATH (WIDTH
VARIES)
VEHICULAR POST TYPE 2 OR 3,
SEE DETAIL AND SHEETS
L111-L114 FOR POST AND SIGN
TYPE
POSITION 3A
PARALLEL TO ROAD
POSITION 3B
PARALLEL TO ROAD
EP OR EDGE OF CURB
POSITION 4B
PARALLEL TO SIDEWALK
POSITION 4A
PERPENDICULAR TO SIDEWALK
CONCRETE
SIDEWALK OR
ASPHALT PATH
(WIDTH VARIES)
CAMPUS SIGNAGE
POST, SEE DETAIL
AND SHEETS
L121-L123 FOR POST
AND SIGN TYPE
DRIVE AISLE, EDGE
OF PAVEMENT OR
CURB AND GUTTER.
POSITION 4C
ROTATED TO SIDEWALK
NOTE:
1. SIGN TYPE VARIES. MASONRY BASE SIGNS AND POST
MOUNTED SIGNS ARE SHOWN FOR EXAMPLE AND
REFERENCE. SEE DETAIL AND SHEETS L121-L123 FOR
POST AND SIGN TYPE.
EDGE OF CONCRETE
COLLAR, TYP.
EDGE OF MASONRY
BASE CAP, TYP.
SIGN PANEL, TYP.
EDGE OF CONCRETE
PAD, TYP.
EP OR EDGE OF
CURB
CAMPUS SIGNAGE POST,
SEE DETAIL AND SHEETS
L121-L123 FOR POST AND
SIGN TYPE
POSITION 5A
PERPENDICULAR TO ROAD
POSITION 5B
PARALLEL TO ROAD
EDGE OF CONCRETE
COLLAR, TYP.
EP OR EDGE OF CURB
EDGE OF MASONRY
BASE CAP, TYP.
SIGN PANEL, TYP.
LAWN
EDGE OF CONCRETE
PAD, TYP.
POSITION 5C
ROTATED TO ROAD
NOTE:
1. SIGN TYPE VARIES. MASONRY BASE SIGNS AND POST
MOUNTED SIGNS ARE SHOWN FOR EXAMPLE AND
REFERENCE. SEE DETAIL AND SHEETS L121-L123 FOR
POST AND SIGN TYPE.
EDGE OF CONCRETE
COLLAR, TYP.
EP OR EDGE OF CURB
EDGE OF MASONRY
BASE CAP, TYP.
SIGN PANEL, TYP.
LAWN
EDGE OF CONCRETE
PAD, TYP.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER
321 4 5 6 7 8 9 10
06/25/2021 BAC IPBRevisions: Date:
AE INSTALL SIGNS & HISTORICAL
SITE ENHANCE
#621-20-104
MT. HOME, TENNESSEE
CONSTRUCTION
BID DOCUMENTS SITE
JAMES H.
QUILLEN VA
MEDICAL
CENTER
95% REVIEW 06/08/2021
LAN
DSCAPE ARCHITEC
T
Lic. No. 01972
IAN P. BUCHANANCO
M M
ONWEALTH OF VIRGIN
IA
L507
CAMPUS SIGNAGE DETAILS
A SIGN AND POST POSITIONING 1
SCALE: 1/2" = 1'-0"
B SIGN AND POST POSITIONING 2
SCALE: 3/8" = 1'-0" C SIGN AND POST POSITIONING 3
SCALE: 3/8" = 1'-0"
D SIGN AND POST POSITIONING 4
SCALE: 3/8" = 1'-0" E SIGN AND POST POSITIONING 5
SCALE: 3/8" = 1'-0"
MRI
8"
8"
T R A
IL
O R
TO JCMC
(MED. CENTER)
T O
E
TS
U
SO
UT
HE
RN
R R
40 41
8"
6"
4"
6" 6"
4"
6" 4"
6"
6"
8"
12"12"
12"
12" 8"
6"
8"
6"
6" 6"
4" PVC
(2/99)ESG
CONST.
TRAILOR
(6/90)
8" PVC
(6/90)
8" PVC
5"N.H C.I.
(6/90)
(6/90) C.I.
5"N.H
12" 12" 12" 12"
6" 4" 4"
8" 8"
6"
6"
6" 6"
4"
4"
8"
15"
15"
6"
24"
24" 18"
15"
24"
24"
24"
8"
10" 15"
15"
15"
15"
C.O.
C.O.
6"
8" 8"
8"
8"
8"
6"
8"
8" 3"
BRUSH
CREE
K
LA
KE
D R.
E
AS
T
LAKE DR. WEST
DOGWOOD AVE.
F I F T H
S T
MAPLE AVE.
MEMORIAL AVE.
F O U R T H
S T
T H I R D
S T
MEMORIAL AVE.
MAPLE AVE.
MAGNOLIA
AVE.
S E C O N D
S T
FIR
ST
ST.
LAMONT
ST.
S
ID
N E Y
S T
DOGWOOD AVE.
BROWNLOW
CI
RC
LE
LAKE
BRUSH
CREE
K
ASHE AVE.
BRADFORD PEAR LANE
S. FIRST
ST.
PEA
CE
AVE
CEMETERY
M
AINT. RD.
PEACE AVE.
S U N S E T
D R
FREEDOM RD.
CEMETERY
VI
CT
OR
Y
LN
SUNSET DR.
FREE
DOM
RD.
VICTORY LN.
A105
A
A107
A
A102
A101
G E N E R A L N O T E S
1. COORDINATE LOCATION OF ALL ADDITIONAL WORK WITH CIVIL DRAWINGS.
2. 100'-0" EQUALS 1711 FEET ON CIVIL DRAWINGS.
3. EXISTING COLUMNS ARE IONIC ORDER BUT DRAWN IN THE DORIC ORDER.
4. THIS STRUCTURE IS HISTORICAL AND CHANGES SHOWN HAVE BEEN APROVED. NO DEVIATIONS
FROM THE PROPOSED DRAWINGS SHALL BE ALLOWED.
5. HISTORICAL MASONRY RESTORATON REQUIREMENTS:
A. MASONRY CONTRACTOR TO REVIEW EXISTING CONDITIONS AND REVIEW WITH
C.O.R PRIOR TO ANY REPAIR WORK PROCEEDING RECOMMENDATIONS FOR
REPAIRING MASONRY WALLS AND OTHER MASONRY FEATURES BY REPOINTING THE
MORTAR JOINTS WHERE THERE IS EVIDENCE OF DETERIORATION, SUCH AS
DISINTEGRATING MORTAR, CRACKS IN MORTAR JOINTS, AND LOOSE BRICKS.
B. USE POWER TOOLS ONLY ON HORIZONTAL JOINTS ON BRICK MASONRY IN
CONJUNCTION WITH HAND CHISELING TO REMOVE HARD MORTAR THAT IS
DETERIORATED OR THAT IS A NON-HISTORIC MATERIAL. MINIMIZE DAMAGE TO THE
MASONRY UNITS. MECHANICAL TOOLS SHOULD BE USED ONLY BY SKILLED MASONS
IN LIMITED CIRCUMSTANCES AND GENERALLY NOT ON SHORT, VERTICAL JOINTS IN
BRICK MASONRY.
C. DUPLICATE HISTORIC MORTAR JOINTS IN STRENGTH, COMPOSITION, COLOR, AND
TEXTURE WHEN REPOINTING IS NECESSARY. IN SOME CASES, A LIME-BASED
MORTAR MAY ALSO BE CONSIDERED WHEN REPOINTING PORTLAND CEMENT
MORTAR BECAUSE IT IS MORE FLEXIBLE.
D. LIMIT CLEANING MASONRY SURFACES TO AVOID INTRODUCING CHEMICALS OR
MOISTURE INTO HISTORIC MATERIALS.
E. AVOID CLEANING WITH CHEMICAL PRODUCTS THAT WILL DAMAGE MASONRY,
INCLUDING ACID ON CHEMICALS ON MASONRY SURFACES.
F. DUPLICATE HISTORIC MASONRY IN STRENGTH, COMPOSITION, COLOR, AND
TEXTURE WHEN REPLACED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
9812155 EXPIRES 12/31/2021
PATRICK ALLEN HILLIER
C R e v it U s e r
F ile s \2
\F F
E
M t H o m e
I n s ta ll S ig n s p a tr ic k .h ill ie r@ ff e -s e rv
.c o m
.r v t
/2
/2
:1
:5
P
M
A100
SITE PLAN
06/25/2021 PH CD
AE INSTALL SIGNS AND HISTORICAL
SITE ENHANCE
#621-20-104
MT. HOME, TENNESSEE
CONSTRUCTION BID
DOCUMENTS SITE
JAMES H.
QUILLEN VA
MEDICAL
CENTER
SCALE: 1" = 200'-0"
SITE PLAN
Revisions: Date:
CONSTRUCTION DOCUMENTS 06/25/2021
File details come from the government source that posted it. Updated .