Drawing Part-12.pdf
PDF 2 MB Posted
- Solicitation number
- 36C24921B0013
About this file
This document package includes a federal solicitation for construction services and supporting documents. The Department of Veterans Affairs is seeking bids to complete project 621-20-104 to install historic site enhancements at the James H. Quillen VA Medical Center in Mountain Home, Tennessee. Key requirements include replacing an existing building roof, installing new signage, lighting and landscaping, with work to be completed within 180 calendar days of the notice to proceed. The solicitation is set aside 100% for service-disabled veteran-owned small businesses. Bids are due on February 1, 2022 and the pre-bid site visit will be held on January 11, 2022. The selected contractor must adhere to VA privacy, security, and environmental standards and processes.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24921B0013 0006.pdf | ||
| 36C24921B0013 0005.pdf | ||
| 36C24921B0013 0004.pdf | ||
| Specification 073126.pdf | ||
| 36C24921B0013 0003.pdf | ||
| 32 18 27 -02792-PLAYGROUND SURFACING - POURED RUBBER.pdf | ||
| 36C24921B0013 0002.pdf | ||
| 36C24921B0013 0001.pdf | ||
| Specifications.pdf | ||
| Drawing Part-5.pdf | ||
| Drawing Part-7.pdf | ||
| Drawing Part-4.pdf | ||
| Drawing Part-11.pdf | ||
| Drawing Part-1.pdf | ||
| 36C24921B0013_3.docx | DOCX document | |
| Drawing Part-9.pdf | ||
| RFI Form - Install Historic Site Enhancements.pdf | ||
| Drawing Part-6.pdf | ||
| Drawing Part-8.pdf | ||
| Drawing Part-10.pdf | ||
| WD 20220191 9-2-2022.pdf | ||
| Contractor EMR Certification Form.pdf | ||
| Drawing Part-3.pdf | ||
| Drawing Part-2.pdf | ||
| Header - List of Attachments.txt | TXT text file | |
| Drawing Part-13.pdf |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W P
/G F
W P
/G F
C
IR
C
LE
GAZ-N1A
EXISTING PANEL
FL1
FL1
FL1
FL1
GAZ-N1-6,8
GAZ-N1-6,8
GAZ-N1-6,8
GAZ-N1-6,8
P2
GAZ-N1
EXISTING
PANEL
P1
P1
P1
P1
GAZ-N1A-9
GAZ-N1A-9
GAZ-N1A-9
GAZ-N1A-9
GAZ-N1A-9
GAZ-N1A-9
GAZ-N1A
EXISTING
PANEL
PB
PB
HAND HOLE WITH FLUSH COVER
FINISHED GRADE
PVC CONDUIT ADAPTER
COUPLING
PVC CONDUIT
RIGID STEEL CONDUIT
UNDISTURBED SOIL
OR SELECT BACKFILL
COMPACTED. SEE
NOTE BELOW.
#4 BARE COPPER
GROUND 6069mm
(10'-0") COILED
BELOW BASE
CONCRETE BASE &
REINFORCED STEEL.
SEE NOTE BELOW.
(2
GENERAL NOTES:
1. REFER TO SPECIFICATION SECTION 26 56 00 FOR MOUNTING AND LEVELING REQUIREMENTS.
(6
POLE GROUNDING STUD
2" DIAMETER BASE
ANCHOR BOLTS
JUNCTION BOX
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER
321 4 5 6 7 8 9 10
06/25/2021
C U s e rs
\c h e ls \D o c u m e n ts \F
F E
M t H o m e
I n s ta ll S ig n s c h e ls e y .g a lli o n
.r v t
/2
/2
:4
:4
P
M
E101B
ENLARGED ELECTRICAL SITE
PLAN
06/25/2021 JB CLG
AE INSTALL SIGNS AND HISTORICAL
SITE ENHANCE
#621-20-104
MT. HOME, TENNESSEE
CONSTRUCTION BID
DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1/8" = 1'-0"
ELECTRICAL PLAN - BAND STAND
1/8" = 1'-0"
ELECTRICAL PLAN - PAVILION
1. EXISTING FLOOD LIGHT TO BE REMOVED. REMOVE EXISTING FLOOD LIGHTS AND
EXISTING CONCRETE BASE. EXTEND EXISTING CIRCUITRY TO NEW FLOOD LIGHT
LOCATIONS.
2. EXISTING FAN TO BE REPLACED UNDER REHABILITATION PLAN. REFER TO
ARCHITECTURAL REHABILITATION PLAN. MAINTAIN CIRCUITRY AND CONTROLS FOR
NEW FAN.
3. PROVIDE NEW WEATHERPROOF/GROUND FAULT RECEPTACLES AT PAVILION.
CIRCUIT FROM GAZEBO PANEL. PROVIDE 0.75" PVC CONDUIT FROM GAZEBO PANEL
TO PAVILION FOR RECEPTACLE CIRCUIT. PROVIDE NEW 20A/1P BREAKER IN PANEL
FOR NEW CIRCUIT. REFER TO OVERALL SITE PLAN FOR PAVILION AND GAZEBO
LOCATION.
4. NEW FLOOD LIGHT. PROVIDE NEW CONCRETE BASE. EXTEND EXISTING CONDUIT
AND WIRING TO NEW FLOOD LIGHTS. NEW FLOOD LIGHTS SHALL BE CONNECTED
TO EXISTING CONTROLS. REFER TO FLOOD BASE DETAIL FOR MOUNTING.
5. DIRECTIONAL BORE BELOW ROADWAYS TO INSTALL NEW 0.75" CONDUIT FOR
PAVILION.
6. REMOVE AND REPAIR SIDEWALK TO INSTALL NEW 0.75" CONDUIT FROM GAZEBO
PANEL TO PAVILION.
7. PROVIDE SINGLE POLE SWITCH FOR PAVILLION LIGHTING. PROVIDE WEATHER
PROOF BOX FOR SWITCH.
8. PROVIDE NEW PULLBOX FOR CIRCUIT. PROVIDE COMPOSITE BOX WITH TIER 15
COVER. PROVIDE COVER WITH TEXT THAT READS "ELECTRIC".
D R A W I N G N O T E S
1" = 30'-0"
ELECTRICAL PLAN - GAZEBO
N.T.S
FLOOD LIGHT BASE DETAIL
ALL WORK ASSOCIATED WITH BAND STAND
REHABILITATION PLAN ON THIS SHEET -
ALTERNATE #1
ALL WORK ASSOCIATED WITH PAVILION ON
THIS SHEET - ALTERNATE #2
Notes:
Total Est. Demand Current: 1 A
Total Conn. Current: 1 A
Total Est. Demand: 432 VA
Receptacle 360 VA 100.00% 360 VA Total Conn. Load: 432 VA
Lighting 72 VA 100.00% 72 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 0 A 4 A 0 A
Total Load: 0 VA 432 VA 0 VA
11 Space -- -- 0 VA 0 VA -- -- -- 12
9 Pavilion Lights/Receptacles 20 A 1 432 VA 0 VA -- -- -- 10
7 Existing 20 A 1 0 VA 0 VA 3 30 A Spare 8
5 Existing 20 A 1 0 VA 0 VA 1 20 A Existing 6
3 Existing 20 A 1 0 VA 0 VA 1 20 A Existing 4
1 Existing 20 A 1 0 VA 0 VA 1 20 A Existing 2
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
Notes:
Enclosure: Type 1 MCB Rating: 100 A
Mounting: Surface Wires: 4 Mains Rating: 100 A
Supply From: Phases: 3 Mains Type: MCB
Location: Volts: 120/208 Wye A.I.C. Rating: 10,000 A
Branch Panel: GAZ-N1A
Revisions: Date:
F
IF
T H
S T
MAPLE AVE.
PL3
PL3
PL3
PL3
PL3a PL3a
PL3a
PL3a
PL3a
PL3a
PL3a
PL3a
PL5a
PL3a
PL3a
PL3a
PL3a
PL3a
PL3a
PL3a
PL3a
PL3a
PL3a PL3a PL3a
PL3a
PL3
PL3 PL3 PL3
PL3
PL3PL3
PL5
PL5
PL5a
PL3a PL3a PL3a PL3a
PL3a
PL5
PL3a
PL5a
PL5a
PL3
PL3 PL5
PL5
PL5a
G E N E R A L N O T E S
A. PEDESTRIAN LIGHT POLE LOCATIONS ARE EXISTING. NEW LED PEDESTRIAN POST TOP LIGHT
SHALL BE INSTALLED ON EXISTING POLES. EXISTING CIRCUITS AND CONTROLS SHALL BE
MAINTAINED AND UTILIZED FOR NEW LIGHTS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER
321 4 5 6 7 8 9 10
06/25/2021
C U s e rs
\c h e ls \D o c u m e n ts \F
F E
M t H o m e
I n s ta ll S ig n s c h e ls e y .g a lli o n
.r v t
/2
/2
:4
:4
P
M
E102
ELECTRICAL SITE PLAN - AREA A
06/25/2021 JB CLG
AE INSTALL SIGNS AND HISTORICAL
SITE ENHANCE
#621-20-104
MT. HOME, TENNESSEE
CONSTRUCTION BID
DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1" = 30'-0"
ELECTRICAL SITE PLAN
MEMORIAL AVE.
F O U R T H
S T
T H
IR
D
S T
MEMORIAL AVE.
MAPLE AVE.
MAGNOLIA
AVE.
S U N S E T
D R
PL3
PL3 PL3
PL3
PL3
PL3
PL3
PL5
PL5
PL3
PL5
PL3
PL3
PL3
PL3
PL3
PL3
PL3
G E N E R A L N O T E S
A. PEDESTRIAN LIGHT POLE LOCATIONS ARE EXISTING. NEW LED PEDESTRIAN POST TOP LIGHT
SHALL BE INSTALLED ON EXISTING POLES. EXISTING CIRCUITS AND CONTROLS SHALL BE
MAINTAINED AND UTILIZED FOR NEW LIGHTS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER
321 4 5 6 7 8 9 10
06/25/2021
C U s e rs
\c h e ls \D o c u m e n ts \F
F E
M t H o m e
I n s ta ll S ig n s c h e ls e y .g a lli o n
.r v t
/2
/2
:4
:4
P
M
E103
ELECTRICAL SITE PLAN - AREA B
06/25/2021 JB CLG
AE INSTALL SIGNS AND HISTORICAL
SITE ENHANCE
#621-20-104
MT. HOME, TENNESSEE
CONSTRUCTION BID
DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1" = 30'-0"
ELECTRICAL SITE PLAN - AREA B
S E C O N D
S T
F
IR
S T
S T
S F
IR
S T
S T
PL3
PL5
PL5
PL5
PL5
PL5
PL3
PL3
PL3
PL3
PL3
PL3
PL5
PL5
PL5
PL3
PL3
PL5
PL5
PL3PL3
PL3
PL3
PL5
PL5
PL3
PL3
PL3
PL3
PL3
PL5
PL3
PL3
PL5
PL5
PL3
PL5
PL5
PL5
PL3
PL3
G E N E R A L N O T E S
A. PEDESTRIAN LIGHT POLE LOCATIONS ARE EXISTING. NEW LED PEDESTRIAN POST TOP LIGHT
SHALL BE INSTALLED ON EXISTING POLES. EXISTING CIRCUITS AND CONTROLS SHALL BE
MAINTAINED AND UTILIZED FOR NEW LIGHTS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER
321 4 5 6 7 8 9 10
06/25/2021
C U s e rs
\c h e ls \D o c u m e n ts \F
F E
M t H o m e
I n s ta ll S ig n s c h e ls e y .g a lli o n
.r v t
/2
/2
:4
:5
P
M
E104
ELECTRICAL SITE PLAN - AREA C
06/25/2021 JB CLG
AE INSTALL SIGNS AND HISTORICAL
SITE ENHANCE
#621-20-104
MT. HOME, TENNESSEE
CONSTRUCTION BID
DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1" = 30'-0"
ELECTRICAL SITE PLAN - AREA C
DOGWOOD AVE.
PL3
PL3
PL3
PL5
PL5
PL3
PL5
PL3
PL3
PL3
PL3
PL3
PL3 PL3
PL3
PL5
PL3
PL3
PL3
G E N E R A L N O T E S
A. PEDESTRIAN LIGHT POLE LOCATIONS ARE EXISTING. NEW LED PEDESTRIAN POST TOP LIGHT
SHALL BE INSTALLED ON EXISTING POLES. EXISTING CIRCUITS AND CONTROLS SHALL BE
MAINTAINED AND UTILIZED FOR NEW LIGHTS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER
321 4 5 6 7 8 9 10
06/25/2021
C U s e rs
\c h e ls \D o c u m e n ts \F
F E
M t H o m e
I n s ta ll S ig n s c h e ls e y .g a lli o n
.r v t
/2
/2
:4
:5
P
M
E105
ELECTRICAL SITE PLAN - AREA D
06/25/2021 JB CLG
AE INSTALL SIGNS AND HISTORICAL
SITE ENHANCE
#621-20-104
MT. HOME, TENNESSEE
CONSTRUCTION BID
DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1" = 30'-0"
ELECTRICAL SITE PLAN - AREA D
Revisions: Date:
VHAMOULopezJ Image
VHAMOULopezJ Engineer
VHAMOULopezJ Line
VHAMOULopezJ PolyLine
VHAMOULopezJ Line
VHAMOULopezJ Polygon
VHAMOULopezJ Typewritten Text
PL5
VHAMOULopezJ Polygon
VHAMOULopezJ Polygon
VHAMOULopezJ Polygon
VHAMOULopezJ Polygon
VHAMOULopezJ Polygon
VHAMOULopezJ Polygon
VHAMOULopezJ Polygon
VHAMOULopezJ Typewritten Text
PL5
VHAMOULopezJ Typewritten Text
PL5
VHAMOULopezJ Typewritten Text
PL5
VHAMOULopezJ Typewritten Text
PL5
VHAMOULopezJ Typewritten Text
PL5
VHAMOULopezJ Typewritten Text
PL5
VHAMOULopezJ Typewritten Text
PL5
VHAMOULopezJ PolyLine
VHAMOULopezJ PolyLine
VHAMOULopezJ PolyLine
VHAMOULopezJ PolyLine
VHAMOULopezJ PolyLine
VHAMOULopezJ PolyLine
VHAMOULopezJ PolyLine
VHAMOULopezJ PolyLine
VHAMOULopezJ Image
F O U R T H
S T
BROW
N
LOW
C
IR
C
LE
PL3
PL3 PL3
PL3
PL3 PL5
PL3PL3PL3PL3PL3
PL3 PL3
PL3PL3
PL3
PL3
PL3 PL3
PL3PL3
PL3
PL3
G E N E R A L N O T E S
A. PEDESTRIAN LIGHT POLE LOCATIONS ARE EXISTING. NEW LED PEDESTRIAN POST TOP LIGHT
SHALL BE INSTALLED ON EXISTING POLES. EXISTING CIRCUITS AND CONTROLS SHALL BE
MAINTAINED AND UTILIZED FOR NEW LIGHTS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER
321 4 5 6 7 8 9 10
06/25/2021
C U s e rs
\c h e ls \D o c u m e n ts \F
F E
M t H o m e
I n s ta ll S ig n s c h e ls e y .g a lli o n
.r v t
/2
/2
:4
:5
P
M
E106
ELECTRICAL SITE PLAN - AREA E
06/25/2021 JB CLG
AE INSTALL SIGNS AND HISTORICAL
SITE ENHANCE
#621-20-104
MT. HOME, TENNESSEE
CONSTRUCTION BID
DOCUMENTS
JAMES H.
QUILLEN VA
MEDICAL
CENTER
1" = 30'-0"
ELECTRICAL SITE PLAN - AREA E