Drawing Part-12.pdf

PDF 2 MB Posted

Attached to
Z1DA-- Project 621-20-104 - Install Historic Site Enhancements
Solicitation number
36C24921B0013
Issued by

About this file

This document package includes a federal solicitation for construction services and supporting documents. The Department of Veterans Affairs is seeking bids to complete project 621-20-104 to install historic site enhancements at the James H. Quillen VA Medical Center in Mountain Home, Tennessee. Key requirements include replacing an existing building roof, installing new signage, lighting and landscaping, with work to be completed within 180 calendar days of the notice to proceed. The solicitation is set aside 100% for service-disabled veteran-owned small businesses. Bids are due on February 1, 2022 and the pre-bid site visit will be held on January 11, 2022. The selected contractor must adhere to VA privacy, security, and environmental standards and processes.

View the file

Other files

File Type Posted
36C24921B0013 0006.pdf PDF
36C24921B0013 0005.pdf PDF
36C24921B0013 0004.pdf PDF
Specification 073126.pdf PDF
36C24921B0013 0003.pdf PDF
32 18 27 -02792-PLAYGROUND SURFACING - POURED RUBBER.pdf PDF
36C24921B0013 0002.pdf PDF
36C24921B0013 0001.pdf PDF
Specifications.pdf PDF
Drawing Part-5.pdf PDF
Drawing Part-7.pdf PDF
Drawing Part-4.pdf PDF
Drawing Part-11.pdf PDF
Drawing Part-1.pdf PDF
36C24921B0013_3.docx DOCX document
Drawing Part-9.pdf PDF
RFI Form - Install Historic Site Enhancements.pdf PDF
Drawing Part-6.pdf PDF
Drawing Part-8.pdf PDF
Drawing Part-10.pdf PDF
WD 20220191 9-2-2022.pdf PDF
Contractor EMR Certification Form.pdf PDF
Drawing Part-3.pdf PDF
Drawing Part-2.pdf PDF
Header - List of Attachments.txt TXT text file
Drawing Part-13.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W P

/G F

W P

/G F

C

IR

C

LE

GAZ-N1A

EXISTING PANEL

FL1

FL1

FL1

FL1

GAZ-N1-6,8

GAZ-N1-6,8

GAZ-N1-6,8

GAZ-N1-6,8

P2

GAZ-N1

EXISTING

PANEL

P1

P1

P1

P1

GAZ-N1A-9

GAZ-N1A-9

GAZ-N1A-9

GAZ-N1A-9

GAZ-N1A-9

GAZ-N1A-9

GAZ-N1A

EXISTING

PANEL

PB

PB

HAND HOLE WITH FLUSH COVER

FINISHED GRADE

PVC CONDUIT ADAPTER

COUPLING

PVC CONDUIT

RIGID STEEL CONDUIT

UNDISTURBED SOIL

OR SELECT BACKFILL

COMPACTED. SEE

NOTE BELOW.

#4 BARE COPPER

GROUND 6069mm

(10'-0") COILED

BELOW BASE

CONCRETE BASE &

REINFORCED STEEL.

SEE NOTE BELOW.

(2

GENERAL NOTES:

1. REFER TO SPECIFICATION SECTION 26 56 00 FOR MOUNTING AND LEVELING REQUIREMENTS.

(6

POLE GROUNDING STUD

2" DIAMETER BASE

ANCHOR BOLTS

JUNCTION BOX

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER

321 4 5 6 7 8 9 10

06/25/2021

C U s e rs

\c h e ls \D o c u m e n ts \F

F E

M t H o m e

I n s ta ll S ig n s c h e ls e y .g a lli o n

.r v t

/2

/2

:4

:4

P

M

E101B

ENLARGED ELECTRICAL SITE

PLAN

06/25/2021 JB CLG

AE INSTALL SIGNS AND HISTORICAL

SITE ENHANCE

#621-20-104

MT. HOME, TENNESSEE

CONSTRUCTION BID

DOCUMENTS

JAMES H.

QUILLEN VA

MEDICAL

CENTER

1/8" = 1'-0"

ELECTRICAL PLAN - BAND STAND

1/8" = 1'-0"

ELECTRICAL PLAN - PAVILION

1. EXISTING FLOOD LIGHT TO BE REMOVED. REMOVE EXISTING FLOOD LIGHTS AND

EXISTING CONCRETE BASE. EXTEND EXISTING CIRCUITRY TO NEW FLOOD LIGHT

LOCATIONS.

2. EXISTING FAN TO BE REPLACED UNDER REHABILITATION PLAN. REFER TO

ARCHITECTURAL REHABILITATION PLAN. MAINTAIN CIRCUITRY AND CONTROLS FOR

NEW FAN.

3. PROVIDE NEW WEATHERPROOF/GROUND FAULT RECEPTACLES AT PAVILION.

CIRCUIT FROM GAZEBO PANEL. PROVIDE 0.75" PVC CONDUIT FROM GAZEBO PANEL

TO PAVILION FOR RECEPTACLE CIRCUIT. PROVIDE NEW 20A/1P BREAKER IN PANEL

FOR NEW CIRCUIT. REFER TO OVERALL SITE PLAN FOR PAVILION AND GAZEBO

LOCATION.

4. NEW FLOOD LIGHT. PROVIDE NEW CONCRETE BASE. EXTEND EXISTING CONDUIT

AND WIRING TO NEW FLOOD LIGHTS. NEW FLOOD LIGHTS SHALL BE CONNECTED

TO EXISTING CONTROLS. REFER TO FLOOD BASE DETAIL FOR MOUNTING.

5. DIRECTIONAL BORE BELOW ROADWAYS TO INSTALL NEW 0.75" CONDUIT FOR

PAVILION.

6. REMOVE AND REPAIR SIDEWALK TO INSTALL NEW 0.75" CONDUIT FROM GAZEBO

PANEL TO PAVILION.

7. PROVIDE SINGLE POLE SWITCH FOR PAVILLION LIGHTING. PROVIDE WEATHER

PROOF BOX FOR SWITCH.

8. PROVIDE NEW PULLBOX FOR CIRCUIT. PROVIDE COMPOSITE BOX WITH TIER 15

COVER. PROVIDE COVER WITH TEXT THAT READS "ELECTRIC".

D R A W I N G N O T E S

1" = 30'-0"

ELECTRICAL PLAN - GAZEBO

N.T.S

FLOOD LIGHT BASE DETAIL

ALL WORK ASSOCIATED WITH BAND STAND

REHABILITATION PLAN ON THIS SHEET -

ALTERNATE #1

ALL WORK ASSOCIATED WITH PAVILION ON

THIS SHEET - ALTERNATE #2

Notes:

Total Est. Demand Current: 1 A

Total Conn. Current: 1 A

Total Est. Demand: 432 VA

Receptacle 360 VA 100.00% 360 VA Total Conn. Load: 432 VA

Lighting 72 VA 100.00% 72 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 0 A 4 A 0 A

Total Load: 0 VA 432 VA 0 VA

11 Space -- -- 0 VA 0 VA -- -- -- 12

9 Pavilion Lights/Receptacles 20 A 1 432 VA 0 VA -- -- -- 10

7 Existing 20 A 1 0 VA 0 VA 3 30 A Spare 8

5 Existing 20 A 1 0 VA 0 VA 1 20 A Existing 6

3 Existing 20 A 1 0 VA 0 VA 1 20 A Existing 4

1 Existing 20 A 1 0 VA 0 VA 1 20 A Existing 2

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Notes:

Enclosure: Type 1 MCB Rating: 100 A

Mounting: Surface Wires: 4 Mains Rating: 100 A

Supply From: Phases: 3 Mains Type: MCB

Location: Volts: 120/208 Wye A.I.C. Rating: 10,000 A

Branch Panel: GAZ-N1A

Revisions: Date:

F

IF

T H

S T

MAPLE AVE.

PL3

PL3

PL3

PL3

PL3a PL3a

PL3a

PL3a

PL3a

PL3a

PL3a

PL3a

PL5a

PL3a

PL3a

PL3a

PL3a

PL3a

PL3a

PL3a

PL3a

PL3a

PL3a PL3a PL3a

PL3a

PL3

PL3 PL3 PL3

PL3

PL3PL3

PL5

PL5

PL5a

PL3a PL3a PL3a PL3a

PL3a

PL5

PL3a

PL5a

PL5a

PL3

PL3 PL5

PL5

PL5a

G E N E R A L N O T E S

A. PEDESTRIAN LIGHT POLE LOCATIONS ARE EXISTING. NEW LED PEDESTRIAN POST TOP LIGHT

SHALL BE INSTALLED ON EXISTING POLES. EXISTING CIRCUITS AND CONTROLS SHALL BE

MAINTAINED AND UTILIZED FOR NEW LIGHTS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER

321 4 5 6 7 8 9 10

06/25/2021

C U s e rs

\c h e ls \D o c u m e n ts \F

F E

M t H o m e

I n s ta ll S ig n s c h e ls e y .g a lli o n

.r v t

/2

/2

:4

:4

P

M

E102

ELECTRICAL SITE PLAN - AREA A

06/25/2021 JB CLG

AE INSTALL SIGNS AND HISTORICAL

SITE ENHANCE

#621-20-104

MT. HOME, TENNESSEE

CONSTRUCTION BID

DOCUMENTS

JAMES H.

QUILLEN VA

MEDICAL

CENTER

1" = 30'-0"

ELECTRICAL SITE PLAN

MEMORIAL AVE.

F O U R T H

S T

T H

IR

D

S T

MEMORIAL AVE.

MAPLE AVE.

MAGNOLIA

AVE.

S U N S E T

D R

PL3

PL3 PL3

PL3

PL3

PL3

PL3

PL5

PL5

PL3

PL5

PL3

PL3

PL3

PL3

PL3

PL3

PL3

G E N E R A L N O T E S

A. PEDESTRIAN LIGHT POLE LOCATIONS ARE EXISTING. NEW LED PEDESTRIAN POST TOP LIGHT

SHALL BE INSTALLED ON EXISTING POLES. EXISTING CIRCUITS AND CONTROLS SHALL BE

MAINTAINED AND UTILIZED FOR NEW LIGHTS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER

321 4 5 6 7 8 9 10

06/25/2021

C U s e rs

\c h e ls \D o c u m e n ts \F

F E

M t H o m e

I n s ta ll S ig n s c h e ls e y .g a lli o n

.r v t

/2

/2

:4

:4

P

M

E103

ELECTRICAL SITE PLAN - AREA B

06/25/2021 JB CLG

AE INSTALL SIGNS AND HISTORICAL

SITE ENHANCE

#621-20-104

MT. HOME, TENNESSEE

CONSTRUCTION BID

DOCUMENTS

JAMES H.

QUILLEN VA

MEDICAL

CENTER

1" = 30'-0"

ELECTRICAL SITE PLAN - AREA B

S E C O N D

S T

F

IR

S T

S T

S F

IR

S T

S T

PL3

PL5

PL5

PL5

PL5

PL5

PL3

PL3

PL3

PL3

PL3

PL3

PL5

PL5

PL5

PL3

PL3

PL5

PL5

PL3PL3

PL3

PL3

PL5

PL5

PL3

PL3

PL3

PL3

PL3

PL5

PL3

PL3

PL5

PL5

PL3

PL5

PL5

PL5

PL3

PL3

G E N E R A L N O T E S

A. PEDESTRIAN LIGHT POLE LOCATIONS ARE EXISTING. NEW LED PEDESTRIAN POST TOP LIGHT

SHALL BE INSTALLED ON EXISTING POLES. EXISTING CIRCUITS AND CONTROLS SHALL BE

MAINTAINED AND UTILIZED FOR NEW LIGHTS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER

321 4 5 6 7 8 9 10

06/25/2021

C U s e rs

\c h e ls \D o c u m e n ts \F

F E

M t H o m e

I n s ta ll S ig n s c h e ls e y .g a lli o n

.r v t

/2

/2

:4

:5

P

M

E104

ELECTRICAL SITE PLAN - AREA C

06/25/2021 JB CLG

AE INSTALL SIGNS AND HISTORICAL

SITE ENHANCE

#621-20-104

MT. HOME, TENNESSEE

CONSTRUCTION BID

DOCUMENTS

JAMES H.

QUILLEN VA

MEDICAL

CENTER

1" = 30'-0"

ELECTRICAL SITE PLAN - AREA C

DOGWOOD AVE.

PL3

PL3

PL3

PL5

PL5

PL3

PL5

PL3

PL3

PL3

PL3

PL3

PL3 PL3

PL3

PL5

PL3

PL3

PL3

G E N E R A L N O T E S

A. PEDESTRIAN LIGHT POLE LOCATIONS ARE EXISTING. NEW LED PEDESTRIAN POST TOP LIGHT

SHALL BE INSTALLED ON EXISTING POLES. EXISTING CIRCUITS AND CONTROLS SHALL BE

MAINTAINED AND UTILIZED FOR NEW LIGHTS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER

321 4 5 6 7 8 9 10

06/25/2021

C U s e rs

\c h e ls \D o c u m e n ts \F

F E

M t H o m e

I n s ta ll S ig n s c h e ls e y .g a lli o n

.r v t

/2

/2

:4

:5

P

M

E105

ELECTRICAL SITE PLAN - AREA D

06/25/2021 JB CLG

AE INSTALL SIGNS AND HISTORICAL

SITE ENHANCE

#621-20-104

MT. HOME, TENNESSEE

CONSTRUCTION BID

DOCUMENTS

JAMES H.

QUILLEN VA

MEDICAL

CENTER

1" = 30'-0"

ELECTRICAL SITE PLAN - AREA D

Revisions: Date:

VHAMOULopezJ Image

VHAMOULopezJ Engineer

VHAMOULopezJ Line

VHAMOULopezJ PolyLine

VHAMOULopezJ Line

VHAMOULopezJ Polygon

VHAMOULopezJ Typewritten Text

PL5

VHAMOULopezJ Polygon

VHAMOULopezJ Polygon

VHAMOULopezJ Polygon

VHAMOULopezJ Polygon

VHAMOULopezJ Polygon

VHAMOULopezJ Polygon

VHAMOULopezJ Polygon

VHAMOULopezJ Typewritten Text

PL5

VHAMOULopezJ Typewritten Text

PL5

VHAMOULopezJ Typewritten Text

PL5

VHAMOULopezJ Typewritten Text

PL5

VHAMOULopezJ Typewritten Text

PL5

VHAMOULopezJ Typewritten Text

PL5

VHAMOULopezJ Typewritten Text

PL5

VHAMOULopezJ PolyLine

VHAMOULopezJ PolyLine

VHAMOULopezJ PolyLine

VHAMOULopezJ PolyLine

VHAMOULopezJ PolyLine

VHAMOULopezJ PolyLine

VHAMOULopezJ PolyLine

VHAMOULopezJ PolyLine

VHAMOULopezJ Image

F O U R T H

S T

BROW

N

LOW

C

IR

C

LE

PL3

PL3 PL3

PL3

PL3 PL5

PL3PL3PL3PL3PL3

PL3 PL3

PL3PL3

PL3

PL3

PL3 PL3

PL3PL3

PL3

PL3

G E N E R A L N O T E S

A. PEDESTRIAN LIGHT POLE LOCATIONS ARE EXISTING. NEW LED PEDESTRIAN POST TOP LIGHT

SHALL BE INSTALLED ON EXISTING POLES. EXISTING CIRCUITS AND CONTROLS SHALL BE

MAINTAINED AND UTILIZED FOR NEW LIGHTS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPLANDSCAPE ARCHITECT / CIVIL ENGINEER

321 4 5 6 7 8 9 10

06/25/2021

C U s e rs

\c h e ls \D o c u m e n ts \F

F E

M t H o m e

I n s ta ll S ig n s c h e ls e y .g a lli o n

.r v t

/2

/2

:4

:5

P

M

E106

ELECTRICAL SITE PLAN - AREA E

06/25/2021 JB CLG

AE INSTALL SIGNS AND HISTORICAL

SITE ENHANCE

#621-20-104

MT. HOME, TENNESSEE

CONSTRUCTION BID

DOCUMENTS

JAMES H.

QUILLEN VA

MEDICAL

CENTER

1" = 30'-0"

ELECTRICAL SITE PLAN - AREA E

File details come from the government source that posted it. Updated .