DRAFT_Drawing 10 MABH-Electrical.pdf

PDF 43 MB Posted

Attached to
Sources Sought - Hospital Modernization Misawa Air Base, Japan Federal contract opportunity
Solicitation number
FA5205-21-PKP-002
Issued by
Department of the Air Force Pacific Air Forces

About this file

This document is a sources sought notice from the Department of the Air Force Pacific Air Forces regarding a pre-solicitation opportunity for the Hospital Modernization project at Misawa Air Base in Japan. The notice provides a draft specification and drawings for informational purposes only, as the government is seeking industry input to determine availability of potential sources and develop an acquisition strategy. No contract awards will be made from this notice, as no solicitation is currently available. Interested parties are encouraged but not required to provide input to assist the government's market analysis and acquisition planning. All costs associated with responding are at the responder's sole expense, and no reimbursement will be provided. Responses will be considered non-binding and used for determining the optimal solicitation approach.

View the file

Other files for this federal contract opportunity

Other files attached to Sources Sought - Hospital Modernization Misawa Air Base, Japan, newest first.
File Type Posted
Sources Sought - Misawa Hospital Modernization_3Feb2021.docx DOCX document
DRAFT_Drawing 05 MABH-Interiors.pdf PDF
DRAFT_Drawing 09 MABH-Mechanical.pdf PDF
DRAFT_Drawing 03 MABH-Structural.pdf PDF
DRAFT_Drawing 06 MABH-Equipment.pdf PDF
DRAFT_Specifications_Volume 1.pdf PDF
DRAFT_Drawing 02 MABH-Civil.pdf PDF
DRAFT_Specifications_Volume 2.pdf PDF
DRAFT_Drawing 01 MABH-General.pdf PDF
DRAFT_Drawing 08 MABH-Plumbing.pdf PDF
Sources Sought - Misawa Hospital Modernization.docx DOCX document
DRAFT_Drawing 04 MABH-Architecture.pdf PDF
DRAFT_Drawing 07 MABH-FireProtection.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CAPACITOR

DESCRIPTIONSYMBOL

CIRCUIT BREAKER

MOTOR STARTER, # INDICATES NEMA STARTER SIZE

CURRENT TRANSFORMER

POTENTIAL TRANSFORMER

DRAWOUT CIRCUIT BREAKER

FUSE

GROUND CONNECTION

GENERATOR

KIRK KEY INTERLOCK

LIGHTNING ARRESTOR

MAGENTIC MOTOR STARTER

METER (AS SPECIFIED)

SWITCH

TRANSFER SWITCH, AUTOMATIC UON

TRANSFORMER

ATS BYPASS

SOLID-STATE MULTI-FUNCTION METER

TRANSFORMER CONFIGURATION

TRANSFORMER CONFIGURATION

AMMETER AND PHASE SELECTOR SWITCH

VOLTMETER AND PHASE SELECTOR SWITCH

PANELBOARD

PREWIRED CONTROL PANEL

SURGE PROTECTIVE DEVICE

DISCONNECT SWITCH

3 WIRE FEEDER TAG

4 WIRE FEEDER TAG

EMERGENCY POWER FEEDER

CT

PT

G

G F P GROUND FAULT PROTECTOR

K

M

3 CT

AAS

VVS

X-X

TRANSIENT VOLTAGE SURGE SUPPRESSION

PWCP

SPD

TVSS

E

LAMP

DESCRIPTIONSYMBOL

N.C. CONTACT

N.O. CONTACT

OVERLOAD RELAYCT

CONTROL DIAGRAM

ONE-LINE DIAGRAM

R

DESCRIPTIONSYMBOL

LIGHT FIXTURES

STANDARD SYMBOL INDICATES NORMAL POWER

FULL HATCHED SYMBOL INDICATES EGRESS LIGHTING CODE

REQUIRED LIFE SAFETY ILLUMINATION OF EGRESS PATH

HALF-SHADED SYMBOL INDICATES EMERGENCY LIGHTING

NON-LIFE SAFETY LIGHTING REQUIRING BACKUP POWER

LIGHT FIXTURE LABELING

A1 a

"A1" INDICATES FIXTURE TYPE

"a" INDICATES CONTROL SWITCHBOARD

"1" INDICATES CIRCUIT NUMBER

INDICATES DIRECTIONAL LIGHTING

RECTANGULAR LUMINAIRE

ROUND LUMINAIRE

LINEAR LUMINAIRE

WALL MOUNTED LINEAR LUMINAIRE

STRIP LUMINAIRE

WALL MOUNTED LUMINAIRE

UNDER CABINET LUMINAIRE

COVE LIGHTING

TRACK LIGHTING, QUANTITY AND ORIENTATION AS SHOWN

SPECIALTY FIXTURE

EXIT SIGN, CEILING OR WALL MOUNT

EMERGENCY LIGHTING UNIT

POLE MOUNTED LIGHTING (HEADS AS INDICATED)

POLE MOUNTED LIGHTING MULTI-HEAD

POLE MOUNTED LIGHTING POST TOP HEAD

BOLLARD LUMINAIRE

FLOOD LIGHTING

IN-GRADE LIGHTING

DESCRIPTIONSYMBOL

SWITCHING AND CONTROL OUTLETS

SINGLE POLE, TOGGLE

TWO SINGLE POLE, TOGGLE, INDICATES BY-LEVEL SWITCHING

PUSH BUTTON, 1219MM A.F.F. UON

DAYLIGHT SENSOR, ON CEILING

OCCUPANCY SENSOR, ON CEILING

PHOTO CELL CONTROL, ON CEILING

POWER PACK FOR OCCUPANCY SENSORS

DS

OS

PC

PP

a

SWITCH LABELING

"a" INDICATES FIXTURES OR BALLAST CONTROLLED BY

SWITCH

"1" INDICATES SWITCH TYPE AS BELOW:

2 = DOUBLE POLE, SINGLE THROW K = KEY OPERATED

3 = THREE WAY M = MOTOR RATED

4 = FOUR WAY MC = MOMENTARY CONTACT

D = DIMMER O = OCCUPANCY SENSOR

P = INTERNAL PILOT LIGHT T = TIMER

TS= TIME SWITCH V = VACANCY SENSOR

LV= LOW VOLTAGE TE= THERMAL ELEMENT

DUPLEX RECEPTACLE

DESCRIPTIONSYMBOL

DUPLEX RECEPTACLE, FLUSH MOUNTED ON CEILING

DUPLEX RECEPTACLE, FLUSH MOUNTED IN FLOOR POKE-

THRU. SEE SYSTEMS PLANS FOR ADDITIONAL DEVICES

DOUBLE DUPLEX RECEPTACLE

DOUBLE DUPLEX RECEPTACLE, FLUSH MOUNTED ON CEILING

DOUBLE DUPLEX RECEPTACLE, FLUSH MOUNTED IN FLOOR

POKE-THRU. SEE SYSTEMS PLANS FOR ADDITIONAL DEVICES

POWER OUTLETS

DUPLEX RECEPTACLE, EMERGENCY POWER

DOUBLE DUPLEX RECEPTACLE, EMERGENCY POWER

DUPLEX RECEPTACLE, SWITCHED

DOUBLE DUPLEX RECEPTACLE, SWITCHED

SINGLE RECEPTACLE

SINGLE RECEPTACLE, EMERGENCY POWER

SPECIAL RECEPTACLE, AS NOTED

MULTI-OUTLET ASSEMBLY, AS NOTED

DESCRIPTIONSYMBOL

POWER DISTRIBUTION

WIRING IDENTIFICATION

LETTER INDICATES PANEL, NUMBERS INDICATE CIRCUITS

CONDUIT CONCEALED IN CEILING OR WALL

CONDUIT DOWNWARD

CONDUIT UPWARD

CONDUIT CONTINUATION

CONDUIT IN DUCTBANK

SURFACE MOUNTED BRANCH PANELBOARD

FLUSH MOUNTED BRANCH PANELBOARD

DISTRIBUTION PANEL

SWITCHBOARD

MOTOR CONTROL CENTER

ELECTRICAL CABINET OR SPECIAL PURPOSE ENCLOSURE

PULL BOX

MANHOLE

HANDHOLE

AUTOMATIC TRANSFER SWITCH

SURGE PROTECTION DEVICE

A-1,3,5

CONDUIT EXPOSED

CONDUIT CONCEALED IN FLOOR OR BELOW GRADE

CONDUIT SEAL

CDB

PB

MH

HH

ATS

SPD

VARIABLE FREQUENCY DEVICEVFD

MOTOR

NON-FUSED DISCONNECT SWITCH

FUSED DISCONNECT SWITCH

INDIVIDUAL MOLDED CASE CIRCUIT BREAKER IN ENCLOSURE

MAGNETIC MOTOR CONTROLLER

COMBINATION MOTOR CONTROLLER AND DISC. SWITCH

J

J

J

JUNCTION BOX, WALL MOUNTED

JUNCTION BOX, FLUSH MOUNTED ON CEILING

JUNCTION BOX, FLUSH MOUNTED IN FLOOR

CONDUIT END CAP

ELECTRICAL SYMBOL LEGEND NOTES

1. ALL SYMBOLS INDICATED ARE NOT NECESSARILY USED ON PLANS.

2. ALL MOUNTING DIMENSIONS GIVEN ARE TO THE CENTERLINE (CL) OF THE

DEVICE AND ABOVE FINISHED FLOOR (A.F.F.) OR ABOVE FINISHED GRADE

(A.F.G.) UNLESS OTHERWISE NOTED.

3. WALL MOUNTED LIGHT SWITCHES ARE TO BE LOCATED 1168MM A.F.F. AND

51MM FROM EDGE OF DOOR FRAME TO EDGE OF DEVICE PLATE.

4. CONVENIENCE OUTLETS SHALL BE MOUNTED 457MM A.F.F. AND SHALL BE

ALIGNED VERTICALLY. PROVIDE HORIZONTAL INSTALLATIONS ONLY WHEN

SPACE IS LIMITED, SUCH AS BETWEEN MIRRORS AND CABINET

BACKSPLASHES. THE GROUND PIN SHALL BE ORIENTED IN THE UP

POSITION.

5. CONVENIENCE OUTLETS LOCATED IN MECHANICAL AND BOILER ROOMS

SHALL BE LOCATED 1168MM A.F.F..

6. CONVENIENCE OUTLETS LOCATED OUTSIDE SHALL BE GFCI AND

WEATHERPROOF RATED, FURNISHED WITH A WEATHERPROOF "WHILE-IN-

USE" COVER AND MOUNTED 610MM A.F.F. OR A.F.G.. EXTERIOR

CONVENIENCE OUTLETS SHALL BE INSTALLED WITHIN 7.62 METERS AND

ON THE SAME LEVEL AS HEATING, AIR CONDITIONING AND

REFRIGERATION EQUIPMENT.

7. MISCELLANEOUS WALL MOUNTED CONTROL DEVICES, SUCH AS SPEAKER

VOLUME CONTROLS, DOOR BELLS, AUTOMATIC DOOR PUSH PADS, ETC.

SHALL BE MOUNTED AT 1168MM A.F.F.

8. WALL MOUNTED LIGHTING FIXTURES SHALL BE MOUNTED AS INDICATED

ON THE DRAWINGS.

9. PANELBOARDS AND OTHER SIMILAR CABINETS SHALL BE MOUNTED

1829MM A.F.F. TO THE TOP.

10. MOTOR CONTROLLERS AND SAFETY SWITCHES SHALL BE MOUNTED

1524MM A.F.F..

11. DEVICE BOXES SHALL BE MOUNTED FLUSH IN WALLS UNLESS OTHERWISE

NOTED OR REQUIRED. FLUSH SHALL BE DEFINED AS EVEN WITH THE FACE

OF THE WALL, OR RECESSED NO MORE THAN 2MM.

12. WALL BOXES FOR SINGLE AND TWO-GANG SWITCH, CONVENIENCE

OUTLET, OR TELECOMMUNICATIONS OR DATA INSTALLATIONS SHALL BE

102MM SQUARE WITH APPROPRIATE SINGLE OR DOUBLE GANG PLASTER

RINGS OF CORRECT DEPTH FOR WALL CONSTRUCTION. SECTIONAL OR

MULTI-GANG BOXES WITH APPROPRIATE PLASTER RINGS SHALL BE USED

FOR MULTI-GANG APPLICATIONS.

13. WHERE DEVICES CONNECTED TO NORMAL AND EMERGENCY POWER

SYSTEMS ARE LOCATED IN THE SAME BOX, PROVIDE LISTED METALIC

BARRIERS AND SEPARATE RACEWAYS. BOXES SHALL BE PROPERLY

CONFIGURED TO ACCEPT BARRIERS.

MOUNTING HEIGHT ABOVE FINISHED FLOOR TO CENTER

LINE OF DEVICE

DESCRIPTIONSYMBOL

SUBSCRIPTS

MOUNT DEVICE 152MM ABOVE COUNTER OR 914MM ABOVE

FINISH FLOOR AT WORKSTATIONS

DEDICATED

EMERGENCY

EXPLOSION PROOF, CLASS GROUP AND DIVISION AS NOTED

UNIT IS CONNECTED TO FIRE ALARM SYSTEM

GROUND FAULT CIRCUIT INTERRUPTER

HOSPITAL GRADE

ISOLATED GROUND

AC

D

E

EX

FA

G

H

IG

UNSWITCHED NIGHT LIGHT

RAINTIGHT NEMA TYPE 3R OR EQUIVALENT

SURGE PROTECTED TYPE RECEPTACLE

TAMPER-RESISTANT

TELEVISION

CONNECTED TO UPS SYSTEM

WEATHERPROOF NEMA TYPE 3 OR EQUIVALENT

NL

RT

SP

T

TV

U

WP

PAN, TILT, ZOOM TYPE CAMERAPTZ

R RELAY

RECESSED FLOOR DUCT, TYPE/SIZE AS INDICATED ON PLANS

POLE MOUNTED TRANSFORMER

3 PHASE POLE MOUNTED TRANSFORMERS

PUSHBUTTON, NUMBER OF BUTTONS AS SHOWN

ALL DUPLEX RECEPTACLES SHALL BE RATED FOR A MINIMUM OF 20 AMPS

UNLESS NOTED OTHERWISE.

PARTIAL CIRCUIT HOME RUN(PART)

UNLESS OTHERWISE NOTEDUON

ELECTRICAL DEMOLITION NOTES

1. ALL ELECTRICAL ITEMS INSTALLED IN WALLS, FLOORS, OR CEILINGS TO BE DEMOLISHED

SHALL BE REMOVED IN THEIR ENTIRETY UNLESS OTHERWISE NOTED OR REQUIRED BY

OTHER CONDITIONS IN THESE DOCUMENTS. SEE DRAWINGS OF ALL OTHER TRADES FOR

EXTENT OF DEMOLITION WORK. ELECTRICAL ITEMS SHALL INCLUDE POWER, LIGHTING, AND

SPECIAL SYSTEMS. REFER ALL QUESTIONS OF APPLICABILITY TO THE CONTRACTING

OFFICER PRIOR TO BID FOR CLARIFICATION; OTHERWISE, FIELD DECISIONS BY THE A/E

SHALL BE BINDING.

2. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE SCOPE OF THE

DEMOLITION WORK AND THAT NOT ALL ITEMS OF ELECTRICAL DEMOLITION ARE

NECESSARILY SHOWN. THE CONTRACTOR SHALL BE REQUIRED TO FIELD VERIFY AND FIELD

DETERMINE THE SCOPE OF THE DEMOLITION WORK PRIOR TO BID. REFER ALL QUESTIONS

TO THE CONTRACTING OFFICER PRIOR TO BID FOR CLARIFICATION.

3. PHASING OF ELECTRICAL DEMOLITION SHALL FOLLOW THAT OF THE GENERAL CONTRACTOR.

COORDINATE REMOVAL OF ELECTRICAL WORK WITH OTHER CONSTRUCTION ACTIVITIES AND

THE REQUIREMENTS OF THE OWNER.

4. THE CONTRACTING OFFICER SHALL HAVE SALVAGE RIGHTS TO ANY ITEMS THAT ARE TO BE

DEMOLISHED. ITEMS SUCH AS SPEAKERS AND CAMERAS AND OTHER ITEMS THAT THE

OWNER WISHES TO SALVAGE SHALL BE CAREFULLY REMOVED AND STORED IN A LOCATION

AS DIRECTED BY THE OWNER THROUGH THE CONTRACTING OFFICER. ALL OTHER ITEMS OF

DEMOLITION SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED

FROM THE SITE.

5. WHERE DEMOLITION WORK WILL INTERRUPT CIRCUIT CONTINUITY TO OTHER AREAS OF THE

FACILITY THAT ARE TO REMAIN IN OPERATION, THEN RACEWAY AND WIRING SHALL BE

INSTALLED TO MAINTAIN THOSE AREAS IN COMPLETE OPERATION. PROVIDE TEMPORARY

CONNECTIONS AS REQUIRED. COORDINATE ANY INTERRUPTIONS WITH THE CONTRACTING

OFFICER AT LEAST TWO WEEKS PRIOR AND ACCOMMODATE THE OWNER'S NEEDS AS

REQUIRED.

6. ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY.

CONDUCTORS SHALL BE REMOVED FROM THE ITEM TO BE DEMOLISHED TO THE SOURCE

OVERCURRENT DEVICE. RACEWAYS WHICH ARE INSTALLED IN OR BELOW FLOORS OR

WITHIN WALLS MAY BE ABANDONED, BUT ALL OVERHEAD OR EXPOSED RACEWAYS SHALL BE

REMOVED. EXPOSED RACEWAYS TO BE ABANDONED SHALL BE REMOVED AND SHALL BE

CUT OR CHISELED AT LEAST 51MM INTO THE WALL OR FLOOR AND THE OPENING GROUTED

SMOOTH.

7. WHERE EXISTING DEVICE OR JUNCTION BOXES MUST REMAIN IN EXISTING WALLS OR

CEILINGS (SUCH AS FOR CIRCUITS THAT MUST BE MAINTAINED TO OTHER AREAS), THEN

THEY SHALL BE FITTED WITH BLANK COVERPLATES.

8. WHERE DISTRIBUTION OR BRANCH CIRCUIT EQUIPMENT (PANELBOARDS, SWITCHBOARDS,

ETC.) IS TO BE REMOVED, THEN ALL CIRCUITS WHICH FEED ITEMS TO REMAIN SHALL BE

RECONNECTED TO NEW DISTRIBUTION OR BRANCH CIRCUIT EQUIPMENT. REFER ALL

QUESTIONS TO THE CONTRACTING OFFICER FOR CLARIFICATION.

9. IF HAZARDOUS MATERIALS (I.E. ASBESTOS, PCB's, ETC.) ARE ENCOUNTERED AT ANY TIME

DURING CONSTRUCTION IN THE WORK AREA, STOP WORK IMMEDIATELY AND CONTACT THE

CONTRACTING OFFICER.

10. REMOVE ALL DEVICES SHOWN ON DEMOLITION PLAN UNLESS OTHERWISE NOTED.

11. REMOVE CABLING BACK TO SOURCE FOR ALL VOICE/DATA OUTLETS BEING REMOVED. ALL

ABANDONED CABLES NOT CONNECTED TO A VOICE/DATA OUTLET IN THE AREA OF

RENOVATION SHALL ALSO BE REMOVED BACK TO THE SOURCE.

ELECTRICAL GENERAL NOTES

1. ALL ELECTRICAL WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE APPLICABLE

EDITIONS OF THE NATIONAL ELECTRICAL CODE (NFPA 70), THE US AIR FORCE UNIFIED

FACILITIES CRITERIA (UFC) AND ITS REFERENCED CODES AND STANDARDS. A CERTIFICATE OF

FINAL ELECTRICAL INSPECTION SHALL BE OBTAINED BY THE CONTRACTOR AT THE

COMPLETION OF THE WORK AND PRESENTED TO THE CONTRACTING OFFICER.

2. THE CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE AND SATISFACTORILY OPERATING

SYSTEMS AS INDICATED ON THE CONTRACT DOCUMENTS. IT IS NOTED THAT THE DRAWINGS

ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENTS OF SYSTEMS AND WORK.

CIRCUIT NUMBERS, INTERCONNECTIONS, HOME RUNS, AND SWITCH LEGS HAVE BEEN SHOWN,

AND THE CONTRACTOR SHALL FURNISH AND INSTALL CONDUIT AND WIRING AS REQUIRED TO

ACCOMPLISH THE FUNCTIONS INDICATED. SPECIAL SYSTEMS DEVICES (COMMUNICATIONS,

SECURITY, ETC.) HAVE BEEN SHOWN AND THE CONTRACTOR SHALL FURNISH AND INSTALL THE

REQUIRED QUANTITIES AND TYPES OF CABLES, CONDUCTORS, RACEWAYS, REMOTE POWER

SUPPLIES AND CONNECTIONS, SHIELDING REQUIREMENTS, ETC., AS REQUIRED BY THE SYSTEM

MANUFACTURER, THE CONTRACT DOCUMENTS, AND ANY APPLICABLE CODES.

3. THE CONTRACTOR SHALL COORDINATE THE ELECTRICAL WORK WITH THE WORK OF ALL OTHER

TRADES SO AS TO AVOID CONFLICTS. RESOLVE ALL CONFLICTS THROUGH THE A/E PRIOR TO

ROUGH-IN. FAILURE TO PROVIDE SUCH COORDINATION PRIOR TO WORK BEING INSTALLED

SHALL NOT BE CAUSE FOR ADDITIONAL COMPENSATION TO THE CONTRACTOR, AND MAY

RESULT IN REJECTION OF THE WORK. IT IS THE CONTRACTORS' RESPONSIBILITY TO

COORDINATE SUBSTITUTIONS WITH OTHER TRADES.

4. ALL MATERIALS SHALL BE NEW, SHALL BE SUITABLE FOR THE APPLICATION INTENDED, AND

SHALL BEAR LABELS OR MARKINGS INDICATING THIRD PARTY TESTING LABORATORY LISTINGS

ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION UNLESS OTHERWISE NOTED.

5. VERIFY LOCATIONS OF LIGHTING FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLANS

AND THE PLANS OF ALL OTHER TRADES. COORDINATE FIXTURE RECESSING DEPTHS WITH

MECHANICAL WORK AND COORDINATE ACCORDINGLY.

6. ALL WIRING FOR POWER AND LIGHTING SYSTEMS SHALL BE INSTALLED IN METALLIC RACEWAY

SYSTEMS UNLESS OTHERWISE NOTED. ALL CONDUCTORS SHALL BE COPPER, SHALL BE 4MM2

MINIMUM, AND SHALL HAVE 600V TYPE THHN/THWN INSULATION, UNLESS OTHERWISE NOTED.

ALL RACEWAYS AND CIRCUITS SHALL INCLUDE INSULATED GROUND CONDUCTORS SIZED AS

INDICATED OR AS REQUIRED BY THE NEC. MINIMUM RACEWAY SIZE SHALL BE 21MM UNLESS

OTHERWISE NOTED.

7. RACEWAYS SHALL NOT CONTAIN MORE THAN THREE PHASE CONDUCTORS, THREE NEUTRALS,

AND ONE GROUND CONDUCTOR, UNLESS OTHERWISE NOTED. CONTRACTOR SHALL PROVIDE

SEPARATE NEUTRALS FOR ALL 20A/1P CIRCUIT BREAKERS. PROVIDING MULTI-POLE CIRCUIT

BREAKERS IN CONJUNCTION WITH SHARED NEUTRALS IN A MULTI-WIRE CIRCUIT IN

ACCORDANCE WITH 2017 NEC 210.4 SHALL REQUIRE PRIOR APPROVAL BY THE ENGINEER.

8. EXPOSED RACEWAY UP TO 2.44 METERS ABOVE FINISHED FLOOR OR GRADE ELEVATION, OR

ANY RACEWAY SUBJECT TO DAMAGE, SHALL BE RMC.

9. ALL CONNECTIONS FOR ELECTRICALLY POWERED EQUIPMENT, INCLUDING BUT NOT LIMITED TO

MECHANICAL AND OWNER SUPPLIED EQUIPMENT, SHALL BE FURNISHED AND INSTALLED.

WHERE NOT INDICATED AS BEING PROVIDED WITH THE EQUIPMENT, ALL REQUIRED

DISCONNECTING MEANS SHALL BE FURNISHED AND INSTALLED AS A PART OF THE ELECTRICAL

WORK. COORDINATE LOCATIONS OF DISCONNECTING AND CONTROLLING MEANS WITH

EQUIPMENT TO MAINTAIN CODE AND INSTALLATION REQUIREMENTS. DEDICATED WORKING

SPACE FOR MOTOR CONTROLLERS AND SAFETY SWITCHES SHALL BE PER NEC 110.26

REQUIREMENTS.

10. ALL RACEWAY AND WIRING SHALL BE CONCEALED IN FINISHED SPACES, AND MAY BE

INSTALLED EXPOSED IN UNFINISHED SPACES SUCH AS MECHANICAL AND ELECTRICAL ROOMS.

ALL RACEWAY AND WIRING, WHETHER CONCEALED OR EXPOSED, SHALL BE RUN EITHER

PERPENDICULAR OR PARALLEL TO THE BUILDING'S STRUCTURAL COMPONENTS.

11. PROVIDE PULL AND JUNCTION BOXES AS REQUIRED TO MEET CODE AND INSTALLATION

REQUIREMENTS. PULL AND JUNCTION BOXES SHALL BE CONCEALED IN FINISHED SPACES AND

LOCATIONS SHALL BE COORDINATED WITH THE WORK OF ALL OTHER TRADES SO AS TO AVOID

CONFLICTS.

12. ALL CONDUCTORS SHALL BE IDENTIFIED AT EACH JUNCTION BOX, OUTLET BOX, CABINET, PULL

BOX, ETC., WITH VINYL SELF-ADHESIVE TAGS INDICATING PANEL AND CIRCUIT NUMBER,

CONTROL WIRE IDENTIFICATION NUMBER, OR OTHER APPROPRIATE INFORMATION. ALL PULL

AND JUNCTION BOXES SHALL BE LABELED AS TO FUNCTION.

13. ALL EQUIPMENT SHALL BE SECURELY FASTENED BY MEANS OF ANCHORS, RODS, HANGERS,

SUPPORTS, GUIDES, SWAY BRACES, ETC., TO MAINTAIN ALIGNMENT AND PREVENT EQUIPMENT

MOVEMENT.

14. ALL PENETRATIONS OF FIRE OR SMOKE RATED CONSTRUCTION SHALL BE SEALED WITH

FIRESTOPPING MATERIALS APPROVED AND LISTED FOR THE RATING OF THE CONSTRUCTION

TO BE PENETRATED. PROVIDE DOCUMENTATION ON ALL SUCH PENETRATION SEALING

SYSTEMS FOR VERIFICATION OF PROPER INSTALLATION.

15. ALL PENETRATIONS OF ROOFS, EXTERIOR WALLS, FOUNDATIONS, OR OTHER WATER OR

MOISTURE PROOF CONSTRUCTION SHALL BE SEALED WITH APPROPRIATE SEALING FITTINGS

OR SEALED CONSTRUCTION TO PREVENT THE INTRODUCTION OF MOISTURE INTO THE

BUILDING.

16. WHERE EMPTY RACEWAYS ARE INSTALLED, THEY SHALL BE LABELED AT BOTH ENDS AND

FITTED WITH NYLON PULLSTRINGS FOR FUTURE USE.

17. TO PREVENT PERSONNEL INJURY AND POTENTIAL SYSTEM FAILURE, ELECTRICAL WORK SHALL

BE PERFORMED ON DE-ENERGIZED SYSTEMS ONLY. WHERE WORK ON EXISTING SYSTEMS WILL

REQUIRE INTERRUPTION OF ELECTRICAL SERVICE, THEN TEMPORARY PROVISIONS

ACCEPTABLE TO THE CONTRACTING OFFICER FOR TEMPORARY POWER SHALL BE UTILIZED

UNTIL THE WORK IS COMPLETE. PROVIDE ARC FLASH LABELS AND SHORT CIRCUIT RATINGS

FOR ALL SWITCHBOARDS, PANELBOARDS, AND MOTOR CONTROL CENTERS.

18. WHERE 20A, 120V LIGHTING AND POWER CIRCUIT LENGTHS EXCEED 30.5 METERS, PROVIDE

6MM2 PHASE AND NEUTRAL CONDUCTORS WITH 6MM2 GND IN MIN. 21MM CONDUIT.

19. IF THE CONTRACTOR SUBSTITUTES EQUIPMENT WITH DIFFERENT CHARACTERISTICS THAN

WHAT IS SPECIFIED, INCLUDING ELECTRICAL CHARACTERISTICS, IT IS THE CONTRACTORS

RESPONSIBILITY TO COORDINATE THESE DIFFERENCES WITH OTHER TRADES.

20. INSTALL CEILING MOUNTED OCCUPANCY SENSORS AT LEAST 152MM AWAY FROM AIR

DIFFUSERS.

21. IN SPACES WITH WALL-MOUNTED TILE WORK, COORDINATE EXACT LOCATION OF ELECTRICAL

ROUGH-IN WITH PROPOSED TILE PATTERN TO MINIMIZE THE AMOUNT OF TILE CUTTING

REQUIRED.

22. RECEPTACLES INSTALLED IN BATHROOMS SHALL BE GROUND FAULT - CIRCUIT INTERRUPTER

TYPE.

23. DEVICE BOXES SHALL BE MOUNTED FLUSH IN WALLS UNLESS OTHERWISE NOTED OR

REQUIRED. FLUSH SHALL BE DEFINED AS EVEN WITH THE FACE OF THE WALL, OR RECESSED

NO MORE THAN 2MM. J-BOXES INSTALLED WITH PLASTER RINGS TO BE FLUSH WITH WALL.

EXAMPLE: WALLS WITH 16MM THICK SHEET ROCK REQUIRES 19MM PLASTER RING. PROVIDE

PLASTER RINGS AS REQUIRED FOR VARYING WALL THICKNESS COVERINGS. J-BOXES TO BE

SUPPORTED WITH STUD-TO-STUD BACK BOX BRACING.

24. WALL BOXES FOR SINGLE AND TWO-GANG SWITCHES, CONVENIENCE OUTLETS, SHALL BE

102MM SQUARE. TELECOMMUNICATION OR DATA WALL BOXES SHALL BE 119MM SQUARE BY

54MM DEEP. WALLS WITH 16MM THICK SHEET ROCK REQUIRE 19MM PLASTER RING. PROVIDE

SINGLE OR DOUBLE GANG PLASTER RINGS OF CORRECT DEPTH FOR WALL CONSTRUCTION

FOR VARYING WALL THICKNESS COVERINGS. J-BOXES TO BE SUPPORTED WITH STUD-TO-STUD

BACK BOX BRACING. SECTIONAL OR MULTI-GANG BOXES WITH APPROPRIATE PLASTER RINGS

SHALL BE USED FOR MULTI-GANG APPLICATIONS.

25. REFER TO ARCHITECTURAL SHEETS AE101A-C1.3 AND AE101A-C3 FOR TEMPORARY ELECTRICAL

WORK TO BE PERFORMED DURING THE DENTAL CLINIC ADDITION AND RENOVATION.

26. POKE-THRU DEVICES SHALL BE MULTI-SERVICE TYPE AND CONTAIN DEVICES AS SHOWN ON

PLAN. SEE SYSTEMS PLANS FOR ADDITIONAL DEVICES. SIMILAR TO LEGRAND/WIREMOLD RC4

SERIES.

EPROJECT NO.:

CONSTR. CONTR. NO.

DRAWING NO.

SCALE:

SHEET

D E

P A

R T

M E

N T

O F

T H

E A

IR

F

O R

C E

A F

M S

A H

E A

L T

H F

A C

IL

IT

IE

S

D

IV

IS

IO

N

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

P A

C

IF

IC

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

DES

SUBMITTAL DATE

DRW CHK

ACTIVITY

FOR COMMANDER AFCEC

APPROVED

D D

C

B

A

54321

A

C

1 2 3 4 5

B

DRAWFORM

REVISION:

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A

REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY

A/E INFO

SEAL

FA8903-15-D-0004 TO: 18-F-0072

APPROVED BY

23 DECEMBER 2019

L E

G A

C Y

P R

O J

E C

T

Q K

K A

O

P P

O R

T U

N

IT

Y

1 : 1

/1

/2

:2

:2

A

M C

U se rs b jh o ff m an n

D o cu m en ts

A u to d es k\ R ev it

P ro je ct s\

M A

B H

-E le ct ri ca l_ b jh o ff m an n .r vt

E001

E

LE

C T

R

IC

A L

S Y

M B

O

LS

A N

D G

E N

E R

A L

N O

T E

S

F Y

H

O S

P

IT

A L M

O D

E R

N

IZ

A T

IO

N

M

IS

A W

A A

IR

B

A S

E

J A

P A

N

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

JKN BJH JKN

8600 Indian Hills Drive

Omaha, NE 68114-4039

Tel 402.391.8111 Fax

402.391.8564

L A

D P ro je c t N o -1

-0

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R bjhoffmann Snapshot

DESCRIPTIONSYMBOL

TELECOMMUNICATION

VOICE OUTLET

DATA OUTLET, # DENOTES NUMBER OF DATA DROPS UP TO 4

VOICE/DATA OUTLET

SAME AS INDICATED ABOVE EXCEPT CIRCULAR SYMBOLS

INDICATE FLUSH MOUNTED IN CEILING AND SQUARE SYMBOLS

INDICATE FLUSH MOUNTED IN FLOOR

CABLE TRAY - TYPE/SIZE AS INDICATED ON PLANS

WAP1

DAS

WIRELESS ACCESS POINT - GOVERNMENT WIRELESS NETWORK

DISTRIBUTED ANTENNA SYSTEM ANTENNA

TELECOMMUNICATIONS CABINET

TELECOMMUNICATIONS RACK

TELECOMMUNICATIONS GROUND BAR

TELECOMMUNICATIONS MAIN GROUND BAR

TGB

TMGB

SPEAKER ZONE IDENTIFICATION FOR THE ROOM OR AREA

TELEVISION OUTLET, ON CEILING

TELEVISION OUTLET, WALL MOUNTED 1524MM A.F.F. UON

SPEAKER, ON CEILING

SPEAKER, WALL MOUNTED 2286MM A.F.F. UON

VOLUME CONTROL, WALL MOUNTED 1168MM A.F.F. UON

INTERCOM STATION, WALL MOUNTED 1168MM A.F.F. UON

MICROPHONE, WALL MOUNTED 1168MM A.F.F. UON

Z1

TV

TV

S

S

V

I

M

BIOMETRIC READER

DESCRIPTIONSYMBOL

SECURITY

BALANCED MAGNETIC SWITCH

CARD READER

DURESS ALARM

DOOR CONTACT

ELECTROMAGNETIC DOOR HOLDER

ELECTRIC DOOR LOCK

ELECTRIC DOOR STRIKE

SENSOR - GLASS BREAK

INTERCOM MASTER

INTERCOM SUBSTATION

JUNCTION BOX

BR

BMS

CR

DA

DC

DH

DL

EC

GB

IM

IS

J

KEYPAD

LIGHT - LED MARQUEE DISPLAY

LIGHT - STROBE

K

LM

LS

MAGNETIC LOCKMAG

SENSOR - MOTION DETECTOR

SENSOR - EMERGENCY SHOWER MONITOR

SENSOR - TEMPERATURE

PUSHBUTTON - EMERGENCY ASSISTANCE

MD

MS

MT

PA

PUSHBUTTON - GENERIC

PUSHBUTTON - OVERRIDE

PUSHBUTTON - REMOTE RELEASE

PB

PO

PR

REQUEST TO EXITREX

CARD READER AND KEYPAD COMBINATIONRK

SECURITY SPEAKER

CONTROL UNIT WITH KEYPAD

VIDEO MONITOR

SS

U

VM

CLOSED CIRCUIT TELEVISION CAMERA, # INDICATES TYPE

ACCESS CONTROL PANEL

TEMPERATURE MONITORING CONTROL PANEL

ACP

TMCP

TELECOMMUNICATIONS SYMBOL LEGEND NOTES

1. ALL MOUNTING DIMENSIONS GIVEN ARE TO THE CENTERLINE (CL) OF THE

DEVICE AND ABOVE FINISHED FLOOR (A.F.F.) OR ABOVE FINISHED GRADE

(A.F.G.) UNLESS OTHERWISE NOTED (UON).

2. OUTLETS INDICATED AS BEING FOR WALL MOUNTED TELEPHONES SHALL

BE LOCATED 1372MM A.F.F. UNLESS OTHERWISE NOTED.

3. OUTLETS FOR WALL MOUNTED TELECOMMUNICATION OR COMPUTER

DEVICES SHALL BE LOCATED 457MM A.F.F. UON AND SHALL BE ALIGNED

VERTICALLY. PROVIDE HORIZONTAL INSTALLATIONS ONLY WHEN SPACE

IS LIMITED, SUCH AS BETWEEN MIRRORS AND CABINET BACKSPLASHES.

4. MISCELLANEOUS WALL MOUNTED CONTROL DEVICES, SUCH AS SPEAKER

VOLUME CONTROLS, DOOR BELLS, AUTOMATIC DOOR PUSH PADS, ETC.

SHALL BE MOUNTED AT 1168MM A.F.F UON.

5. TELEPHONE PANELS AND OTHER SIMILAR CABINETS SHALL BE MOUNTED

1828MM A.F.F. TO THE TOP.

6. DEVICE BOXES SHALL BE MOUNTED FLUSH IN WALLS UNLESS OTHERWISE

NOTED OR REQUIRED. FLUSH SHALL BE DEFINED AS EVEN WITH THE FACE

OF THE WALL, OR RECESSED NO MORE THAN 2MM.

7. WALL BOXES FOR SINGLE AND TWO-GANG SWITCH, CONVENIENCE

OUTLET, OR TELECOMMUNICATIONS OR DATA INSTALLATIONS SHALL BE

102MM SQUARE WITH APPROPRIATE SINGLE OR DOUBLE GANG PLASTER

RINGS OF CORRECT DEPTH FOR WALL CONSTRUCTION. SECTIONAL OR

MULTI-GANG BOXES WITH APPROPRIATE PLASTER RINGS SHALL BE USED

FOR MULTI-GANG APPLICATIONS.

MOUNTING HEIGHT A.F.F. TO CENTER LINE OF DEVICE, MOUNTING

HEIGHT SHALL NOT BE LESS THAN 304MM

DESCRIPTIONSYMBOL

SUBSCRIPTS

MOUNT DEVICE 152MM ABOVE COUNTER OR 914MM A.F.F. AT

WORKSTATIONS

DEDICATED

EMERGENCY

EXPLOSION PROOF, CLASS GROUP AND DIVISION AS NOTED

UNIT IS CONNECTED TO FIRE ALARM SYSTEM

PATIENT MONITOR NETWORK CONNECTION

AC

D

E

EX

FA

M

RAINTIGHT NEMA TYPE 3R OR EQUIVALENT

TAMPER-RESISTANT

TELEVISION

CONNECTED TO UPS SYSTEM

WEATHERPROOF NEMA TYPE 3 OR EQUIVALENT

RT

T

TV

U

WP

PAN, TILT, ZOOM TYPE CAMERAPTZ

C CHIME

SOUND MASKING SPEAKER WITH SOUND GENERATOR, ON CELINGSM

HOSPITAL GRADEH

19MM PLYWOOD, PAINTED W/ 2 COATS FIRE PROOF GREY PAINT

C SYNCHRONIZED TIME CLOCK, WALL MOUNTED 2150MM A.F.F. UON

WAP2 WIRELESS ACCESS POINT - PUBLIC WIRELESS NETWORK

PATIENT BED SINGLE-STATION

DESCRIPTIONSYMBOL

NURSE CALL

PATIENT BED DUAL-STATION

CODE BLUE STATION

EMERGENCY PULL CORD STATION

MASTER STATION

PATIENT MONITORING OUTLET

STAFF STATION/STAFF EMERGENCY

NURSE CALL CONTROL PANEL

CORRIDOR DOME STATUS LIGHT

CORRIDOR ZONE STATUS LIGHT

CORRIDOR DOME STATUS LIGHT

CORRIDOR ZONE STATUS LIGHT

NL

NZ

N1

N2

NB

NE

NM

NP

NS

NL

NZ

NCCP

BACK BOX REQUIREMENTS

MOUNTING HEIGHT A.F.F,

UNLESS OTHERWISE NOTED

(TYP.)

1168MM

1168MM

1168MM

914MM

AT NURSE STATION

1168MM

1168MM

ON CEILING

ON CEILING

2286MM

2286MM

DUTY STATIONND 1168MM

PATIENT BED PIN RECEPTACLEBP 610MM

CODE PINK STATIONCP 1168MM

100MM SQUARE BOX WITH SINGLE GANG PLASTER RING, 54MM DEEP

100MM SQUARE BOX WITH SINGLE GANG PLASTER RING, 54MM DEEP

3-GANG (NON-GANGABLE), 89MM DEEP

100MM SQUARE BOX WITH SINGLE GANG PLASTER RING, 54MM DEEP

3-GANG (NON-GANGABLE), 89MM DEEP

100MM SQUARE BOX WITH SINGLE GANG PLASTER RING, 54MM DEEP

100MM SQUARE BOX WITH SINGLE GANG PLASTER RING, 54MM DEEP

3-GANG (NON-GANGABLE), 89MM DEEP

100MM SQUARE BOX WITH SINGLE GANG PLASTER RING, 70MM DEEP

100MM SQUARE BOX WITH SINGLE GANG PLASTER RING, 70MM DEEP

100MM SQUARE BOX WITH SINGLE GANG PLASTER RING, 70MM DEEP

100MM SQUARE BOX WITH SINGLE GANG PLASTER RING, 70MM DEEP

WALL PHONE OUTLET WITH FLUSH-MOUNT WALLPLATEW

360 DEGREE FIELD OF VIEW CAMERA360°

TELECOMMUNICATIONS GENERAL NOTES

1. ALL ELECTRICAL WORK SHALL BE PROVIDED IN STRICT ACCORDANCE WITH THE APPLICABLE

EDITIONS OF THE CODES INDICATED BELOW AND SHALL MEET ANY OTHER APPLICABLE LOCAL,

STATE, AND/OR FEDERAL CODES AND ORDINANCES AS REQUIRED.

DEPARTMENT OF THE ARMY

TECHNICAL CRITERIA FOR THE INSTALLATION OF INFORMATION INFRASTRUCTURE

ARCHITECTURE (I3A) - LATEST EDITION

UNIFIED FACILITIES CRITERIA (UFC)

UFC 3-580-01 - TELECOMMUNICATIONS BUILDING CABLING SYSTEMS PLANNING AND

DESIGN - LATEST EDITION

UFC 4-510-01 - DESIGN: MILITARY MEDICAL FACILITIES - LATEST EDITION

FACILITY GUIDELINES INSTITUTION

GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITALS AND OUTPATIENT

FACILITIES (2014)

BICSI

TDMM MANUAL AND RELATED ANSI/TIA/EIA STANDARDS

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NEC - NATIONAL ELECTRICAL CODE - LATEST EDITION

2. OUTLET BOXES SHALL BE STEEL, 102MM SQUARE, 39MM DEEP, WITH 13MM RAISED PLASTER

RING WHERE RECESSED UNLESS OTHERWISE NOTED. DEVICE BOXES SHALL BE MOUNTED

FLUSH IN WALLS AS INDICATED ON PLANS. FLUSH SHALL BE DEFINED AS EVEN WITH THE FACE

OF THE WALL, OR RECESSED NO MORE THAN 2MM.

3. ALL MOUNTING DIMENSIONS GIVEN ARE TO THE CENTERLINE (CL) OF THE DEVICE ABOVE

FINISHED FLOOR (AFF) OR ABOVE FINISHED GRADE (AFG) UNLESS OTHERWISE NOTED.

4. OUTLETS FOR TELECOMMUNICATIONS OR DATA SHALL BE ALIGNED VERTICALLY. PROVIDE

HORIZONTAL INSTALLATIONS ONLY WHEN SPACE IS LIMITED, SUCH AS BETWEEN MIRRORS AND

CABINET BACKSPLASHES.

5. WALL VOICE / DATA AND MISCELLANEOUS LOW VOLTAGE OUTLETS SHALL HAVE A SINGLE GANG

PLASTER RING, AN OUTLET BOX AS SPECIFIED AND A 27MM CONDUIT RUN TO THE NEAREST

CABLE TRAY SYSTEM OR BUNDLED DISTRIBUTION RUN IN AREAS WHERE J-HOOKS OR OTHER

TYPES OF DISTRIBUTION SYSTEMS ARE USED. TELECOMMUNICATIONS CONDUITS SHALL NOT

EXCEED 180 DEGREES OR 30.5M WITHOUT ADDING A PULL BOX. PULL BOXES SHALL BE IN-LINE

AND NOT USED TO MAKE A 90 DEGREE TURN. ALL CONDUITS SHALL BE TERMINATED ON BOTH

ENDS WITH INSULATING PLASTIC BUSHINGS. PROVIDE 4-PAIR TYPE CATEGORY 6 CABLES FROM

EACH TELE/DATA RJ45 JACK INDICATED ON THE PLANS TO THE EQUIPMENT RACK IN THE

TELECOMMUNICATIONS ROOM OR PLANNED RACK LOCATION. VERIFY EXACT QUANTITIES &

TERMINATIONS WITH DEVICE NOTATIONS AND DETAILS ON THE PLANS.

6. OUTLETS SHOWN "BACK-TO-BACK" SHALL BE OFFSET TO MAINTAIN ACOUSTICAL AND FIRE

INTEGRITY.

7. PLYWOOD BACKBOARDS SHALL BE RIGIDLY FIXED 20 MM TYPE A-C GRADE PLYWOOD, VOID

FREE, 2440 MM HIGH, WIDTH AS INDICATED, MOUNTED WITH BOTTOM AT 152MM AFF, CAPABLE

OF SUPPORTING ATTACHED EQUIPMENT. PLYWOOD SHALL BE FIRE-RATED.

8. PENETRATIONS OF FIRE RATED WALLS, CEILINGS AND FLOORS SHALL BE SEALED TO MAINTAIN

THEIR INTEGRITY. FOR ONE HOUR FIRE RATED WALLS, DEVICES THAT COVER A WALL AREA

OVER 10320 SQUARE MILLIMETERS SHALL BE PROTECTED BY ONE LAYER OF 16MM THICK, FIRE

RATED, GYPSUM BOARD. FOR TWO HOUR RATED WALLS PROVIDE TWO LAYERS OF FIRE RATED

GYPSUM BOARD. DEVICES SHALL BE ENCLOSED BY THE GYPSUM BOARD, INSTALLED WITH

AUXILIARY FRAMING AS REQUIRED, TO MAINTAIN FIRE RATING OF WALL. WHERE TWO

ELECTRICAL BOXES WHOSE INDIVIDUAL AREAS ARE NOT OVER 10320 SQ. MM. AND ARE

INSTALLED LESS THAN 610MM ON CENTER, ON OPPOSITE SIDES OF A FIRE RATED WALL, THEY

MAY BE PROTECTED BY APPROVED INTUMESCENT PADS IN LIEU OF GYPSUM BOARD BOXING.

9. DEVICE COLOR AND FACEPLATES (ALSO CALLED DEVICE PLATES OR COVER PLATES) TO MATCH

EXISTING IN THE FACILITY.

10. THE CONTRACTOR SHALL PROVIDE COMPLETE AND CODE COMPLIANT OPERATING SYSTEMS AS

INDICATED ON THE CONTRACT DOCUMENTS. THE DRAWINGS ARE DIAGRAMMATIC AND

INDICATE GENERAL ARRANGEMENTS OF SYSTEMS AND WORK. THE CONTRACTOR SHALL

PROVIDE CONDUIT, JUNCTION BOXES AND CONDUCTORS AS REQUIRED.

11. THE CONTRACTOR SHALL COORDINATE THE TELECOMMUNICATIONS WORK WITH THE WORK OF

ALL OTHER TRADES AND EXISTING CONDITIONS SO AS TO AVOID CONFLICTS PRIOR TO ROUGH-

IN. FAILURE TO PROVIDE SUCH COORDINATION PRIOR TO WORK BEING INSTALLED SHALL NOT

BE CAUSE FOR ADDITIONAL COMPENSATION TO THE CONTRACTOR.

12. UNLESS OTHERWISE NOTED, ALL MATERIALS SHALL BE NEW, SHALL BE SUITABLE FOR THE

APPLICATION INTENDED, AND SHALL BEAR LABELS OR MARKINGS INDICATING THIRD PARTY

TESTING AND/OR LABORATORY LISTINGS ACCEPTABLE TO THE GOVERNMENT.

13. COORDINATE LOCATIONS OF WIRING DEVICES IN FINISHED SPACES, MILLWORK, AND

CASEWORK WITH ARCHITECTURAL DRAWINGS, DETAILS, ELEVATIONS, EQUIPMENT AND

FURNITURE LAYOUTS PRIOR TO ROUGH-IN.

14. MINIMUM TELECOMMUNICATIONS RACEWAY SIZE SHALL BE 25MM UNLESS OTHERWISE NOTED.

15. EXPOSED RACEWAY UP TO 2438MM ABOVE FINISHED FLOOR OR GRADE ELEVATION, OR ANY

RACEWAY SUBJECT TO DAMAGE, SHALL BE GALVANIZED RIGID STEEL (GRS) CONDUIT.

16. ALL RACEWAY AND WIRING SHALL BE CONCEALED IN FINISHED SPACES, AND MAY BE

INSTALLED EXPOSED IN UNFINISHED SPACES SUCH AS MECHANICAL AND ELECTRICAL ROOMS

OR WHERE INDICATED OTHERWISE. ALL RACEWAY AND WIRING, WHETHER CONCEALED OR

EXPOSED, SHALL BE RUN EITHER PERPENDICULAR OR PARALLEL TO THE BUILDING'S

STRUCTURAL COMPONENTS. RUN ALL RACEWAYS TIGHT TO STRUCTURE WHEREVER POSSIBLE,

SPECIALLY IN OPEN CEILING AREAS.

17. PROVIDE PULL BOXES AND JUNCTION BOXES AS REQUIRED TO MEET CODE AND INSTALLATION

REQUIREMENTS. PULL BOXES AND JUNCTION BOXES SHALL BE CONCEALED IN FINISHED

SPACES AND LOCATIONS SHALL BE COORDINATED WITH THE WORK OF ALL OTHER TRADES SO

AS TO AVOID CONFLICTS.

18. ALL EQUIPMENT SHALL BE SECURELY FASTENED BY MEANS OF ANCHORS, RODS, HANGERS,

SUPPORTS, GUIDES, SWAY BRACES, ETC., TO MAINTAIN ALIGNMENT AND PREVENT EQUIPMENT

MOVEMENT. ALL EQUIPMENT LOCATED IN SEISMIC ZONES SHALL BE SECURED WITH MEANS

APPROVED FOR THE SEISMIC CLASSIFICATION ENCOUNTERED.

19. PROVIDE CORE DRILL HOLES FOR CONDUIT PENETRATION AS REQUIRED. ALL PENETRATIONS

OF FIRE OR SMOKE RATED CONSTRUCTION SHALL BE SEALED WITH FIRE-STOPPING MATERIALS

APPROVED AND LISTED FOR THE RATING OF THE CONSTRUCTION TO BE PENETRATED.

PROVIDE DOCUMENTATION ON ALL SUCH PENETRATION SEALING SYSTEMS FOR VERIFICATION

OF PROPER INSTALLATION.

20. ALL PENETRATIONS OF ROOFS, EXTERIOR WALLS, FOUNDATIONS, OR OTHER WATER OR

MOISTURE PROOF CONSTRUCTION SHALL BE SEALED WITH APPROPRIATE SEAL FITTINGS OR

SEALED CONSTRUCTION TO PREVENT THE INTRODUCTION OF MOISTURE INTO THE BUILDING.

21. ALL SPARE CONDUITS SHALL BE LABELED AT BOTH ENDS AND FITTED WITH NYLON PULL

STRINGS FOR FUTURE USE.

22. TO PREVENT PERSONNEL INJURY AND POTENTIAL SYSTEM FAILURE, ALL ELECTRICAL WORK

SHALL BE PERFORMED ONLY ON DE-ENERGIZED SYSTEMS AND DE-ENERGIZED EQUIPMENT.

23. FOR WORK REQUIRED TO BE PERFORMED ON LIVE OR ENERGIZED EQUIPMENT, (ARC FLASH OR

ELECTRICAL HAZARD CONDITION), THE CONTRACTORS MUST WEAR PROPER PERSONAL

PROTECTION EQUIPMENT (PPE) IN COMPLIANCE WITH THE OSHA STANDARD 20-CFR, PART 1910 OCCUPATION SAFETY AND HEALTH STANDARDS, 191 SUB PART S (ELECTRICAL) AND NFPA 70E.

24. ALL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER FOLLOWING THE

RECOMMENDATIONS OF THE LATEST NECA 1; "STANDARD FOR GOOD WORKMANSHIP IN

ELECTRICAL CONSTRUCTION".

25. ALL CONDUITS FOR LOW VOLTAGE OUTLETS SHALL BE TERMINATED ON BOTH ENDS WITH

INSULATING PLASTIC BUSHINGS.

26. REFER TO ARCHITECTURAL SHEETS AE101A-C1.3 AND AE101A-C3 FOR TEMPORARY

TELECOMMUNICATIONS WORK TO BE PERFORMED DURING THE DENTAL CLINIC ADDITION AND

RENOVATION.

27. FOR TELECOMMUNICATIONS CABLING, USE EXISTING CABLE TRAYS WHERE AVAILBLE ABOVE

ACCESSIBLE CEILING SPACES. PROVIDE NEW CABLE TRAYS WHERE REQUIRED FOR NEW CABLE

ROUTING. INSTALL CONDUITS ABOVE UNACCESSIBLE CEILINGS AND HARD CEILINGS AS

REQUIRED.

28. WIRELESS SYSTEM ACCESS POINT LOCATIONS ARE FOR REFERENCE ONLY. CONTRACTOR TO

COORDINATE WITH THE WIRELESS ACCESS ANETNNA USED AND LOCAL PROVIDER FOR EXACT

LOCATION AND DISTANCE REQUIRED. ADJUST AND PROVIDE ADDITIONAL ACCESS POINTS AS

REQUIRED.

TELECOMMUNICATIONS AND LOW VOLTAGE SYSTEMS RESPONSIBILITY MATRIX

SYSTEM

CONTRACTOR FURNISHED AND

CONTRACTOR INSTALLED

GOVERNMENT FURNISHED AND

CONTRACTOR INSTALLED

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

REMARKS

ACCESS CONTROL

CCTV X

NURSE CALL X

REFRIGERATION

MONITORING

X

XTIME CLOCK

PAGING X

XVOICE/DATA

ACTIVE EQUIPMENT FURNISHED BY

GOVERNMENT

CATV X

X

GOVERNMENT

WIRELESS

NETWORK

CONTRACTOR TO ROUGH-IN SYSTEM,

GOVERNMENT TO FURNISH ACCESS

POINTS

X

PUBLIC WIRELESS

NETWORK

LOCAL PROVIDER TO FURNISH

ACCESS POINTS

ROUGH-IN - CONTRACTOR TO FURNISH AND INSTALL COMPLETE PATHWAYS (CONDUITS, CABLE TRAYS, AND WIREWAYS), BACKBOXES, OUTLETS, COVERPLATES, CABLES, PULL STRINGS, ETC FOR EQUIPMENT

AND DEVICES BY OTHERS.

X EQUIPMENT FURNISHED AND INSTALLED

BY IO CONTRACTOR

EQUIPMENT FURNISHED AND INSTALLED

BY IO CONTRACTOR

EPROJECT NO.:

CONSTR. CONTR. NO.

DRAWING NO.

SCALE:

SHEET

D E

P A

R T

M E

N T

O F

T H

E A

IR

F

O R

C E

A F

M S

A H

E A

L T

H F

A C

IL

IT

IE

S

D

IV

IS

IO

N

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

P A

C

IF

IC

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

DES

SUBMITTAL DATE

DRW CHK

ACTIVITY

FOR COMMANDER AFCEC

APPROVED

D D

C

B

A

54321

A

C

1 2 3 4 5

B

DRAWFORM

REVISION:

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A

REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY

A/E INFO

SEAL

FA8903-15-D-0004 TO: 18-F-0072

APPROVED BY

23 DECEMBER 2019

L E

G A

C Y

P R

O J

E C

T

Q K

K A

O

P P

O R

T U

N

IT

Y

1 : 1

/1

/2

:2

:2

A

M C

U se rs b jh o ff m an n

D o cu m en ts

A u to d es k\ R ev it

P ro je ct s\

M A

B H

-E le ct ri ca l_ b jh o ff m an n .r vt

E002

T E

LE

C

O M

M S

Y M

B O

LS

A

N D

G E

N E

R A

L N

O T

E S

F Y

H

O S

P

IT

A L M

O D

E R

N

IZ

A T

IO

N

M

IS

A W

A A

IR

B

A S

E

J A

P A

N

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

YWW CAL YWW

8600 Indian Hills Drive

Omaha, NE 68114-4039

Tel 402.391.8111 Fax

402.391.8564

L A

D P ro je c t N o -1

-0

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

Snapshot

1392090220U Rectangle

1392090220U Rectangle

1392090220U Rectangle

PB

PB

PBPB

PB

S R Q P N M L

M-H/C

PGS

GENERATOR

SWITCHGEAR

GS-U

GS-Lc

GS-Lb

GS-La

BATTERY

PANELS

LAE-N

L-N

M S

-1

M S

-U

M S

-L a

M S

-T

IE

M S

-2

M S

-L b

M S

-L c

M S

-L d

TS-Lb1

TS-Ld

TS-Lb2

TS-Lc

TS-Uc

TS-Le

TS-La

TS-Lf

TS-Ub

TS-Lg

TS-Ua

EPT-LCR1-B

M-LCR1

M-LCR2

M-LLS

LLS-2

M-L M-LME M-LX M-LAE2

M-LAE1

BLOOD BANK

TRANSFORMER

x x x x x x x x

NEW PROTECTIVE FENCE

AROUND CABLE RISER

P41

P42

ELEC

LN05

MECH

LN02

P68

A R

E A

A

A R

E A

C A

R E

A B

P73

P74

P75

(TYPICAL)

EXISTING HATCH ABOVE

READINESS WAREHOUSE

LN13

MECH

LN17

GENERATOR

LN09

CORR

LN07

MECH

LN01

SEE DETAIL A3/EP503

FOR CONTINUATION

P79

P79

P79P79P79

1. HALF-TONE ITEMS INDICATE EXISTING TO REMAIN. FULL-TONE ITEMS INDICATE

NEW DEVICE.

2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND EQUIPMENT

LOCATION IN FIELD.

GENERAL NOTES

N

TRUE

NORTH

EPROJECT NO.:

CONSTR. CONTR. NO.

DRAWING NO.

SCALE:

SHEET

D E

P A

R T

M E

N T

O F

T H

E A

IR

F

O R

C E

A F

M S

A H

E A

L T

H F

A C

IL

IT

IE

S

D

IV

IS

IO

N

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

P A

C

IF

IC

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

DES

SUBMITTAL DATE

DRW CHK

ACTIVITY

FOR COMMANDER AFCEC

APPROVED

D D

C

B

A

54321

A

C

1 2 3 4 5

B

DRAWFORM

REVISION:

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A

REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY

A/E INFO

SEAL

FA8903-15-D-0004 TO: 18-F-0072

APPROVED BY

23 DECEMBER 2019

KEY PLAN

A C

B D

E

L E

G A

C Y

P R

O J

E C

T

Q K

K A

O

P P

O R

T U

N

IT

Y

As indicated

/1

/2

:2

:2

A

M C

U se rs b jh o ff m an n

D o cu m en ts

A u to d es k\ R ev it

P ro je ct s\

M A

B H

-E le ct ri ca l_ b jh o ff m an n .r vt

EP100A

P O

W E

R P

LA

N

L O

W E

R L

E V

E L

A R

E A

A

F Y

H

O S

P

IT

A L M

O D

E R

N

IZ

A T

IO

N

M

IS

A W

A A

IR

B

A S

E

J A

P A

N

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

JKN BJH JKN

8600 Indian Hills Drive

Omaha, NE 68114-4039

Tel 402.391.8111 Fax

402.391.8564

L A

D P ro je c t N o -1

-0

SCALE: 1 : 100

POWER PLAN LOWER LEVEL AREA A - NON-PHASED

1m

SCALE: 1:100

0 4m2m1m

KEYNOTE LEGEND

P41 NEW CIRCUIT BREAKER ON SECONDARY SIDE OF BLOOD BANK TRANSFORMER. SEE

ONE LINE DIAGRAM, SHEET EP611.

P42 NEW FIRE PUMP TRANSFER SWITCH AT FIRE PUMP CONTROLLER. SEE ONE LINE

DIAGRAM, SHEETS EP602 AND EP611. COORDINATE FINAL LOCATION WITH FIRE

PROTECTION.

P68 SEE SHEET AE100 FOR FENCE INFORMATION.

P73 NEW FIRE PUMP DISCONNECTING MEANS. SEE ONE LINE DIAGRAM, SHEET EP611.

P74 PULLBOX. SIZE AS REQUIRED.

P75 SEAL CONDUIT AT EXTERIOR WALL PENETRATION.

P79 REPLACE CIRCUIT BREAKER(S) AS SHOWN ON CIRCUIT BREAKER (SHORT CIRCUIT

RATING) UPGRADE SCHEDULE ON SHEET EP620.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

L K J H G F

LAE-BC

P9

ELEC

LB29

A R

E A

A

A R

E A

C A

R E

A B

A R

E A

C

A R

E A

E A

R E

A D

A R

E A

B

1. HALF-TONE ITEMS INDICATE EXISTING TO REMAIN. FULL-TONE ITEMS INDICATE

NEW DEVICE.

2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND EQUIPMENT

LOCATION IN FIELD.

GENERAL NOTES

N

TRUE

NORTH

EPROJECT NO.:

CONSTR. CONTR. NO.

DRAWING NO.

SCALE:

SHEET

D E

P A

R T

M E

N T

O F

T H

E A

IR

F

O R

C E

A F

M S

A H

E A

L T

H F

A C

IL

IT

IE

S

D

IV

IS

IO

N

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

P A

C

IF

IC

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

DES

SUBMITTAL DATE

DRW CHK

ACTIVITY

FOR COMMANDER AFCEC

APPROVED

D D

C

B

A

54321

A

C

1 2 3 4 5

B

DRAWFORM

REVISION:

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A

REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY

A/E INFO

SEAL

FA8903-15-D-0004 TO: 18-F-0072

APPROVED BY

23 DECEMBER 2019

KEY PLAN

A C

B D

E

L E

G A

C Y

P R

O J

E C

T

Q K

K A

O

P P

O R

T U

N

IT

Y

As indicated

/1

/2

:2

:3

A

M C

U se rs b jh o ff m an n

D o cu m en ts

A u to d es k\ R ev it

P ro je ct s\

M A

B H

-E le ct ri ca l_ b jh o ff m an n .r vt

EP100B

P O

W E

R P

L A

N L

O W

E R

L E

V E

L A

R E

A B

F Y

H

O S

P

IT

A L M

O D

E R

N

IZ

A T

IO

N

M

IS

A W

A A

IR

B

A S

E

J A

P A

N

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

JKN BJH JKN

8600 Indian Hills Drive

Omaha, NE 68114-4039

Tel 402.391.8111 Fax

402.391.8564

L A

D P ro je c t N o -1

-0

SCALE: 1 : 100

POWER PLAN LOWER LEVEL AREA B - NON-PHASED

KEYNOTE LEGEND

P9 NEW SECONDARY CIRCUIT BREAKER. SEE ONE LINE DIAGRAM, SHEET EP612.

1m

SCALE: 1:100

0 4m2m1m

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

R Q P N M L K J H G F E

P7

P8

P6

P6 P7

P6P7 P8

P8

ELEV-1

PH03-1

ELEV-1

PH04-1

ELEV-1

PH02-1

G

G

G

G

G

G

G

1. HALF-TONE ITEMS INDICATE EXISTING TO REMAIN. FULL-TONE ITEMS INDICATE

NEW DEVICE.

2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND EQUIPMENT

LOCATION IN FIELD.

GENERAL NOTES

N

TRUE

NORTH

EPROJECT NO.:

CONSTR. CONTR. NO.

DRAWING NO.

SCALE:

SHEET

D E

P A

R T

M E

N T

O F

T H

E A

IR

F

O R

C E

A F

M S

A H

E A

L T

H F

A C

IL

IT

IE

S

D

IV

IS

IO

N

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

P A

C

IF

IC

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

DES

SUBMITTAL DATE

DRW CHK

ACTIVITY

FOR COMMANDER AFCEC

APPROVED

D D

C

B

A

54321

A

C

1 2 3 4 5

B

DRAWFORM

REVISION:

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A

REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY

A/E INFO

SEAL

FA8903-15-D-0004 TO: 18-F-0072

APPROVED BY

23 DECEMBER 2019

A C

KEY PLAN

B

L E

G A

C Y

P R

O J

E C

T

Q K

K A

O

P P

O R

T U

N

IT

Y

As indicated

/1

/2

:2

:5

A

M C

U se rs b jh o ff m an n

D o cu m en ts

A u to d es k\ R ev it

P ro je ct s\

M A

B H

-E le ct ri ca l_ b jh o ff m an n .r vt

EP102

P O

W E

R P

L A

N P

E N

T H

O U

S E

L E

V E

L

F Y

H

O S

P

IT

A L M

O D

E R

N

IZ

A T

IO

N

M

IS

A W

A A

IR

B

A S

E

J A

P A

N

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

JKN BJH JKN

8600 Indian Hills Drive

Omaha, NE 68114-4039

Tel 402.391.8111 Fax

402.391.8564

L A

D P ro je c t N o -1

-0

SCALE: 1 : 200

POWER PLAN PENTHOUSE LEVEL - NON-PHASED

KEYNOTE LEGEND

P6 INTERCEPT EXISTING ELEVATOR CAB CIRCUIT AND INSTALL LOCKABLE

DISCONNECTING MEANS PER NEC 620.53.

P7 NEW ELEVATOR POWER MODULE SEE ONE LINE DIAGRAM, SHEET EP616.

P8 REPLACE RECEPTACLES WITH GFCI TYPE RECEPTACLES IN MACHINE ROOM.

2m

SCALE: 1:200

0 8m4m2m

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

S

U T S R Q P N M L K J H G F E D C B A

ZONE LF18

COMM LF18

ET401

A1

ET401

B1

ET401

A2

COMM LF17

EXISTING

COMM RACK

LH12

N

TRUE

NORTH

EPROJECT NO.:

CONSTR. CONTR. NO.

DRAWING NO.

SCALE:

SHEET

D E

P A

R T

M E

N T

O F

T H

E A

IR

F

O R

C E

A F

M S

A H

E A

L T

H F

A C

IL

IT

IE

S

D

IV

IS

IO

N

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

P A

C

IF

IC

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

DES

SUBMITTAL DATE

DRW CHK

ACTIVITY

FOR COMMANDER AFCEC

APPROVED

D D

C

B

A

54321

A

C

1 2 3 4 5

B

DRAWFORM

REVISION:

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A

REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY

A/E INFO

SEAL

FA8903-15-D-0004 TO: 18-F-0072

APPROVED BY

23 DECEMBER 2019

KEY PLAN

A C

B D

E

L E

G A

C Y

P R

O J

E C

T

Q K

K A

O

P P

O R

T U

N

IT

Y

1 : 250

/1

/2

:3

:3

A

M C

U se rs b jh o ff m an n

D o cu m en ts

A u to d es k\ R ev it

P ro je ct s\

M A

B H

-E le ct ri ca l_ b jh o ff m an n .r vt

ET100

C O

M M

U N

IC

A

T

IO

N S

Z O

N

IN

G P

L A

N L

O W

E R

L E

V E

L

O V

E R

A L L

F Y

H

O S

P

IT

A L M

O D

E R

N

IZ

A T

IO

N

M

IS

A W

A A

IR

B

A S

E

J A

P A

N

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

YWW CAL YWW

8600 Indian Hills Drive

Omaha, NE 68114-4039

Tel 402.391.8111 Fax

402.391.8564

L A

D P ro je c t N o -1

-0

SCALE: 1 : 250

COMMUNICATIONS ZONING PLAN LOWER LEVEL - OVERALL

2.5m

SCALE: 1:250

0 10m5m2.5m

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

WAP2

R Q P N M L K J H G F E D

COMM UE06

ZONE UE06

T15

ET401

D1

ET401

D2

MAIN

SERVER

ROOM

UC22

T35

IN CEILING SPACE

OF FLOOR BELOW

COORDNATE EXACT

WALL PENETRATION

LOCATION IN FIELD

SEE CIVIL SHEET

CS102 FOR

CONTINUATION

ZONE UC22

N

TRUE

NORTH

EPROJECT NO.:

CONSTR. CONTR. NO.

DRAWING NO.

SCALE:

SHEET

D E

P A

R T

M E

N T

O F

T H

E A

IR

F

O R

C E

A F

M S

A H

E A

L T

H F

A C

IL

IT

IE

S

D

IV

IS

IO

N

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

P A

C

IF

IC

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

DES

SUBMITTAL DATE

DRW CHK

ACTIVITY

FOR COMMANDER AFCEC

APPROVED

D D

C

B

A

54321

A

C

1 2 3 4 5

B

DRAWFORM

REVISION:

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A

REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY

A/E INFO

SEAL

FA8903-15-D-0004 TO: 18-F-0072

APPROVED BY

23 DECEMBER 2019

A C

KEY PLAN

B

L E

G A

C Y

P R

O J

E C

T

Q K

K A

O

P P

O R

T U

N

IT

Y

1 : 200

/1

/2

:3

:0

A

M C

U se rs b jh o ff m an n

D o cu m en ts

A u to d es k\ R ev it

P ro je ct s\

M A

B H

-E le ct ri ca l_ b jh o ff m an n .r vt

ET101

C O

M M

U N

IC

A

T

IO

N S

Z O

N

IN

G P

LA

N

G R

O U

N D

L E

V E

L

O V

E R

A

LL

F Y

H

O S

P

IT

A L M

O D

E R

N

IZ

A T

IO

N

M

IS

A W

A A

IR

B

A S

E

J A

P A

N

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

YWW CAL YWW

8600 Indian Hills Drive

Omaha, NE 68114-4039

Tel 402.391.8111 Fax

402.391.8564

L A

D P ro je c t N o -1

-0

SCALE: 1 : 200

COMMUNICATIONS ZONING PLAN GROUND LEVEL - OVERALL

2m

SCALE: 1:200

0 8m4m2m

KEYNOTE LEGEND

T15 (2) 102MM CONDUITS FOR TELECOMMUNICATIONS BACKBONE FROM THE MAIN

COMPUTER ROOM (UC22) TO THE NEW TELECOMMUNICATIONS ROOM (UE06).

PROVIDE (3) 32MM INNERDUCTS IN ONE OF THE 102MM CONDUITS.

T35 PROVIDE ONE (1) 63 MM CONDUIT WITH TWO 25 MM INNER DUCTS FOR 4 STRAND

SINGLE MODE FIBER AND 25-PAIR CAT 6 COPPER CABLES TO THE TEMPORARY

TRAILER. THE TEMPORARY TRAILER WILL BE INSTALELD IN PHASE B1. COORDINATE

WITH THE FACILITY ENGINEER FOR EXACT ROUTING PATH.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1. REFER TO SHEET E001 FOR GENERAL NOTES ON DEMOLITION.

2. ALL EQUIPMENT AND/OR DEVICES SHOWN HALF-TONED ARE EXISTING TO REMAIN.

ALL EQUIPMENT AND/OR DEVICES SHOWN BOLD AND DASHED ARE TO BE

REMOVED IN THEIR ENTIRETY.

GENERAL NOTESL K J H G F

L-TTC-10

L-TTC-11

SF-13 D12

STORAGE

LG27

ELEC

LL05

ELEC

LM23

VEST

LG25

ALL CABLES, TELECOMMUNICATIONS OUTLETS,

PATHWAYS, ELECTRICAL POWER, LIGHTING, AND

EQUIPMENT LOCATED WITHIN THE HATCHED AREA ARE

TO BE DISCONNECTED AND REMOVED DURING THE

PHASE A1 RENOVATION.

OPTOMETRY

OFFICE

LM22

OPTOMETRY EXAM

LM21

OPTOMETRY

SUPPLY

LM19

FLT MED EXAM

LM18

FLT MED EXAM

LM17

FLT MED OFFICE

LM16

FLT MED EXAM

LM15

FLT MED EXAM

LM14

FLT MED EXAM

LM13

ELEC

LL15

FLT MED OFFICE

LL14

F/TLT

LL03

OFFICE

LM01

OFFICE

LM03

SCREENING

LM02

STOR

LL16

OFFICE

LL06

JAN

LM05

TLT

LM04

OFFICE

LL07

NAVY MED/OPTM.

RECORDS

LM06

NAVY MED/OPTM.

LM07

ELEV

L-ELEV

VEST

LM27

NAVY MED/OPTM.

RECORDS

LM08

OPTM. OFFICE

LM12

EYE LANE

LM24

OPTM. FITTING

ROOM

LM11

OPTOMETRY EXAM

LM10

EYE LANE

LM25

STAIR

L-STAIR

D

RADIOLOGY

RECORDS

LF37

RECEPTION

LF36

RAD. OFFICE

LF39

RAD. OFFICE

LF40

COMP.

TOMOGRAPHY

LF42

TLT

LF43

S. UTILITY

LG13

URGENT VITAL

LG14

COMM

LG15A

STOR

LG17A

URGENT WAITING

LG15

JAN

LG18

TLT

LG19

URGENT OFFICE

LG21

SUPPLY

LG22A

OFFICE

LG22B

URGENT TRIAGE

LG20

CORR

LGC5

URGENT MEDS

LG12

CORR

LMC2

CORR

LM26

URGENT

RECEPTION

LG17

TLT

LG16

CORR

LMC1

CORR

LF41

WORK SPACE

LF44

RADIOLOGY

READING

LF38

CORR

LLC2

CORR

LLC4

CORR

LLC1

CORR

LMC3

TLT

LF22

CORR

LF20

ULTRASOUND

LF25

RAD. WORK AREA

LF26

RAD. X-RAY

LF21 L&D SUPPLY

LF08

TLT

LF06

CHAPEL

LF15

TLT

LF16

L&D LOUNGE

LF12

L&D SOILED UTL

LF14

RAD. X-RAY

LF30

TLT

LF31

CORR

LF29

L&D SUPPLY

LF09

STOR

LF33

STOR

LF34

SUPPLY

LF32

URGENT EXAM

LG09

URGENT EXAM

LG10

URGENT EXAM

LG11

BIO. MED. EQ. TECH

SHOP

LG06

OFFICE

LG08

CORR

LGC4A

LOUNGE

LG22C

LINEN

OFFICE/SUPPLY

LG05

LINEN S. LINEN

LG04

LINEN C. LINEN

LG03

VENDING

LG02

CORR

LGC4

CORR

LFC1

CORR

LFC3

CORR

LGC3

STOR

LG01

L&D NURSE

LF13

RAD. STORAGE

LF28

RAD. CONTROL

LF27

L&D MEDICATION

LF11

STOR

LF23

L&D PAT RM

LF05

L&D ANTE

LF04

CORR

LF10

STORAGE

LG26

STORAGE

LG27

A R

E A

A

A R

E A

C A

R E

A B

A R

E A

C

A R

E A

E A

R E

A D

A R

E A

B

N

TRUE

NORTH

EPROJECT NO.:

CONSTR. CONTR. NO.

DRAWING NO.

SCALE:

SHEET

D E

P A

R T

M E

N T

O F

T H

E A

IR

F

O R

C E

A F

M S

A H

E A

L T

H F

A C

IL

IT

IE

S

D

IV

IS

IO

N

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

P A

C

IF

IC

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

DES

SUBMITTAL DATE

DRW CHK

ACTIVITY

FOR COMMANDER AFCEC

APPROVED

D D

C

B

A

54321

A

C

1 2 3 4 5

B

DRAWFORM

REVISION:

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A

REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY

A/E INFO

SEAL

FA8903-15-D-0004 TO: 18-F-0072

APPROVED BY

23 DECEMBER 2019

KEY PLAN

A C

B D

E

L E

G A

C Y

P R

O J

E C

T

Q K

K A

O

P P

O R

T U

N

IT

Y

As indicated

/1

/2

:2

:5

A

M C

U se rs b jh o ff m an n

D o cu m en ts

A u to d es k\ R ev it

P ro je ct s\

M A

B H

-E le ct ri ca l_ b jh o ff m an n .r vt

ED100C-A1

E L

E C

T R

IC

A

L D

E M

O L

IT

IO

N P

L A

N L

O W

E R

L E

V E

L A

R E

A C

P

H A

S E

A

F Y

H

O S

P

IT

A L M

O D

E R

N

IZ

A T

IO

N

M

IS

A W

A A

IR

B

A S

E

J A

P A

N

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

JKN BJH JKN

8600 Indian Hills Drive

Omaha, NE 68114-4039

Tel 402.391.8111 Fax

402.391.8564

L A

D P ro je c t N o -1

-0

SCALE: 1 : 100

ELECTRICAL DEMOLITION PLAN LOWER LEVEL AREA C - PHASE A1

KEYNOTE LEGEND

D12 SEE ONE LINE DIAGRAMS ON SHEET EP606 UNLESS NOTED OTHERWISE.

1m

SCALE: 1:100

0 4m2m1m

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

ALL EQUIPMENT AND/OR DEVICES SHOWN BOLD AND DASHED ARE TO BE

REMOVED IN THEIR ENTIRETY.

GENERAL NOTES

E D C B A

L-TTC-6

SEC-5

LCR-2E

LCR-2D

EF-42

D12

STORM WATER PUMP ROOM

LG30

ELEC

LE25

MECH

LH31

OFFICE

LH30

L&D CL LINEN

LE26

TLT

LE09

ANTE

LE07

TLT

LE11

TLT

LE13

CORR

LG28

STORAGE

LG27

A R

E A

C

A R

E A

E

N

TRUE

NORTH

EPROJECT NO.:

CONSTR. CONTR. NO.

DRAWING NO.

SCALE:

SHEET

D E

P A

R T

M E

N T

O F

T H

E A

IR

F

O R

C E

A F

M S

A H

E A

L T

H F

A C

IL

IT

IE

S

D

IV

IS

IO

N

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

P A

C

IF

IC

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

DES

SUBMITTAL DATE

DRW CHK

ACTIVITY

FOR COMMANDER AFCEC

APPROVED

D D

C

B

A

54321

A

C

1 2 3 4 5

B

DRAWFORM

REVISION:

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A

REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY

A/E INFO

SEAL

FA8903-15-D-0004 TO: 18-F-0072

APPROVED BY

23 DECEMBER 2019

KEY PLAN

A C

B D

E

L E

G A

C Y

P R

O J

E C

T

Q K

K A

O

P P

O R

T U

N

IT

Y

As indicated

/1

/2

:2

:0

A

M C

U se rs b jh o ff m an n

D o cu m en ts

A u to d es k\ R ev it

P ro je ct s\

M A

B H

-E le ct ri ca l_ b jh o ff m an n .r vt

ED100E-A1

E L

E C

T R

IC

A

L D

E M

O L

IT

IO

N P

L A

N L

O W

E R

L E

V E

L A

R E

A E

P

H A

S E

A

F Y

H

O S

P

IT

A L M

O D

E R

N

IZ

A T

IO

N

M

IS

A W

A A

IR

B

A S

E

J A

P A

N

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

JKN BJH JKN

8600 Indian Hills Drive

Omaha, NE 68114-4039

Tel 402.391.8111 Fax

402.391.8564

L A

D P ro je c t N o -1

-0

SCALE: 1 : 100

ELECTRICAL DEMOLITION PLAN LOWER LEVEL AREA E - PHASE A1

KEYNOTE LEGEND

D12 SEE ONE LINE DIAGRAMS ON SHEET EP606 UNLESS NOTED OTHERWISE.

1m

SCALE: 1:100

0 4m2m1m

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

OSOS

B2 B2 B2 B2

B2B2B2B2

L6

TEMPORARY KITCHEN SPACE

LG22

A R

E A

A

A R

E A

C A

R E

A B

A R

E A

C

A R

E A

E A

R E

A D

A R

E A

B

1. HALF-TONE ITEMS INDICATE EXISTING TO REMAIN. FULL-TONE ITEMS INDICATE

NEW.

GENERAL NOTES

N

TRUE

NORTH

EPROJECT NO.:

CONSTR. CONTR. NO.

DRAWING NO.

SCALE:

SHEET

D E

P A

R T

M E

N T

O F

T H

E A

IR

F

O R

C E

A F

M S

A H

E A

L T

H F

A C

IL

IT

IE

S

D

IV

IS

IO

N

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

P A

C

IF

IC

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

DES

SUBMITTAL DATE

DRW CHK

ACTIVITY

FOR COMMANDER AFCEC

APPROVED

D D

C

B

A

54321

A

C

1 2 3 4 5

B

DRAWFORM

REVISION:

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A

REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY

A/E INFO

SEAL

FA8903-15-D-0004 TO: 18-F-0072

APPROVED BY

23 DECEMBER 2019

KEY PLAN

A C

B D

E

L E

G A

C Y

P R

O J

E C

T

Q K

K A

O

P P

O R

T U

N

IT

Y

As indicated

/1

/2

:2

:4

A

M C

U se rs b jh o ff m an n

D o cu m en ts

A u to d es k\ R ev it

P ro je ct s\

M A

B H

-E le ct ri ca l_ b jh o ff m an n .r vt

EL100C-A1

L

IG

H T

IN

G

P L

A N

L O

W E

R L

E V

E L

A R

E A

C

P H

A S

E A

F Y

H

O S

P

IT

A L M

O D

E R

N

IZ

A T

IO

N

M

IS

A W

A A

IR

B

A S

E

J A

P A

N

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

JKN BJH JKN

8600 Indian Hills Drive

Omaha, NE 68114-4039

Tel 402.391.8111 Fax

402.391.8564

L A

D P ro je c t N o -1

-0

1m

SCALE: 1:100

0 4m2m1m

SCALE: 1 : 100

LIGHTING PLAN LOWER LEVEL AREA C - PHASE A1

KEYNOTE LEGEND

L6 CONNECT TO EXISTING NORMAL BRANCH POWER LIGHTING CIRCUIT SERVING THIS

AREA.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1118 1118

P50 P51 P52 P53 P54P53

111811181118

G

6-20R

TEMPORARY KITCHEN SPACE

LG22

LAE-EFH- 10

LAE-EFH- 16

LAE-EFH- 21LAE-EFH- 25

LAE-EFH- 33

L-G- 27 L-G- 30

L-G- 31,33

A R

E A

A

A R

E A

C A

R E

A B

A R

E A

C

A R

E A

E A

R E

A D

A R

E A

B

G

L-G- 29

P72

L-H- 14

1. HALF-TONE ITEMS INDICATE EXISTING TO REMAIN. FULL-TONE ITEMS INDICATE

NEW DEVICE.

2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND EQUIPMENT

LOCATION IN FIELD.

GENERAL NOTES

N

TRUE

NORTH

EPROJECT NO.:

CONSTR. CONTR. NO.

DRAWING NO.

SCALE:

SHEET

D E

P A

R T

M E

N T

O F

T H

E A

IR

F

O R

C E

A F

M S

A H

E A

L T

H F

A C

IL

IT

IE

S

D

IV

IS

IO

N

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

P A

C

IF

IC

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

DES

SUBMITTAL DATE

DRW CHK

ACTIVITY

FOR COMMANDER AFCEC

APPROVED

D D

C

B

A

54321

A

C

1 2 3 4 5

B

DRAWFORM

REVISION:

P L A N N I N G

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

EST. 1915

IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A

REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY

A/E INFO

SEAL

FA8903-15-D-0004 TO: 18-F-0072

APPROVED BY

23 DECEMBER 2019

KEY PLAN

A C

B D

E

L E

G A

C Y

P R

O J

E C

T

Q K

K A

O

P P

O R

T U

N

IT

Y

As indicated

/1

/2

:2

:3

A

M C

U se rs b jh o ff m an n

D o cu m en ts

A u to d es k\ R ev it

P ro je ct s\

M A

B H

-E le ct ri ca l_ b jh o ff m an n .r vt

EP100C-A1

P O

W E

R P

LA

N

L O

W E

R L

E V

E L

A R

E A

C

P H

A S

E A

F Y

H

O S

P

IT

A L M

O D

E R

N

IZ

A T

IO

N

M

IS

A W

A A

IR

B

A S

E

J A

P A

N

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

JKN BJH JKN

8600 Indian Hills Drive

Omaha, NE 68114-4039

Tel 402.391.8111 Fax

402.391.8564

L A

D P ro je c t N o -1

-0

SCALE: 1 : 100

POWER PLAN LOWER LEVEL AREA C - PHASE A1

1m

SCALE: 1:100

0 4m2m1m

KEYNOTE LEGEND

P50 BLENDER, JSN K0810, 120V, 900VA.

P51 COFFEE BREWER, JSN K1550, 120V, 1670VA.

P52 ELECTRIC TOASTER, JSN K8250, 208V, 2200VA, (2) 4MM2, (1) 4MM2 GROUND IN 21MM

CONDUIT.

P53 MICROWAVE, JSN 4660, 120V, 1896VA.

P54 REFRIGERATOR, JSN R7200, 120V, 720VA. PROVIDE DEADFRONT REMOTE-TEST GFCI

OUTLET MOUNTED 152MM ABOVE COUNTER AND LABELED.

P72 FOOD WASTE DISPOSAL, JSN K2620, 120V, 1392VA. PROVIDE POWER TO

CONTROLLER (PROVIDED WITH DISPOSAL) AND CONNECT TO DISPOSAL. IN PHASE

A2, DISCONNECT UNIT/CONTROLLER AND RECONNECT IN NEW LOCATION (ROOM

LH19) AS SHOWN ON SHEET EP100E-A2.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

NZ

NZ

NL

N D

NE

NE

NEN

ND

NM

N L

N E

N L

N S

N E

N L

NL NS

NS

NL

N L

N E

NZ

NZ

NE

N L

NL

NS

N E

N L

ND

ND

NE

NE

NS

NE

N L

NL NL

N M

NE

NE

N S

N S

NS

NL

N L

N L

NZ

N E

NL

C R

L K J H G F

SCOPE OF WORK

TEMPORARY KITCHEN SPACE

LG22

A R

E A

A

A R

E A

C A

R E

A B

A R

E A

C

A R

E A

E A

R E

A D

A R

E A

B

1. HALF-TONE ITEMS INDICATES EXISTING TO REMAIN. FULL-TONE ITEMS INDICATES

NEW.

2. VOICE/DATA CABLES SHALL BE TERMINATED AND PATCHED IN ROOM LF18.

PROVIDE NEW PATCH PANELS AS NEEDED. COORDINATE EXACT LOCATION IN

FIELD.

3. CONTRACTOR SHALL VERIFY EQUIPMENT LOCATION AND MOUNTING HEIGHT

BEFORE INSTALLING CONDUIT AND BACKBOX FOR EQUIPMENT SERVICE

CONNECTION.

GENERAL NOTES

N

TRUE

NORTH

EPROJECT NO.:

CONSTR. CONTR. NO.

DRAWING NO.

SCALE:

SHEET

D E

P A

R T

M E

N T

O F

T H

E A

IR

F

O R

C E

A F

M S

A H

E A

L T

H F

A C

IL

IT

IE

S

D

IV

IS

IO

N

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

P A

C

IF

IC

A

IR

F O

R C

E C

IV

IL

E N

G

IN

E E

R C

E N

T E

R

DES

SUBMITTAL DATE

DRW CHK

ACTIVITY

FOR COMMANDER AFCEC

APPROVED

D D

C

B

A

54321

A

C

1 2 3 4 5

B

DRAWFORM

REVISION:

P L A N N I N G

A R C…

This is the start of the file's text. The full file is on GovTribe.