DRAFT_Drawing 09 MABH-Mechanical.pdf
PDF 25 MB Posted
- Attached to
- Sources Sought - Hospital Modernization Misawa Air Base, Japan Federal contract opportunity
- Solicitation number
- FA5205-21-PKP-002
About this file
This document is a sources sought notice from the Department of the Air Force Pacific Air Forces regarding a pre-solicitation opportunity for hospital modernization at Misawa Air Base in Japan. The notice provides a draft specification and drawings for informational purposes only, as the government is seeking industry input to determine availability of potential sources and develop an acquisition strategy for the project. No contract awards will be made from this notice, as no solicitation is currently available. Interested parties are encouraged but not required to provide input to assist the agency in determining the most effective acquisition approach. All costs associated with responding are the responsibility of the interested party, and responses will not be acknowledged or form any binding agreement. The requested information will only be used within the Air Force to facilitate decision making for the hospital modernization project.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sources Sought - Misawa Hospital Modernization_3Feb2021.docx | DOCX document | |
| DRAFT_Drawing 05 MABH-Interiors.pdf | ||
| DRAFT_Drawing 03 MABH-Structural.pdf | ||
| DRAFT_Drawing 06 MABH-Equipment.pdf | ||
| DRAFT_Drawing 10 MABH-Electrical.pdf | ||
| DRAFT_Specifications_Volume 1.pdf | ||
| Sources Sought - Misawa Hospital Modernization.docx | DOCX document | |
| DRAFT_Drawing 04 MABH-Architecture.pdf | ||
| DRAFT_Drawing 07 MABH-FireProtection.pdf | ||
| DRAFT_Drawing 02 MABH-Civil.pdf | ||
| DRAFT_Specifications_Volume 2.pdf | ||
| DRAFT_Drawing 01 MABH-General.pdf | ||
| DRAFT_Drawing 08 MABH-Plumbing.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L K J H G F
200 CR
32 CS
125 HR
20 125 HR
SF-13
LG22
HS
125 HR
32 HS
350x300 400x350
350x300 400x350
5 LG22C
LG22BLG22A
M A
T C
H L
IN
E
S E
E M
D
E -A
PAC-2 PAC-1
GENERAL DEMO NOTES:
1. ALL ITEMS SHOWN ARE EXISTING. NOT ALL EXISTING
MECHANICAL EQUIPMENT, DUCTWORK, AND PIPING ARE
SHOWN FOR CLARITY. CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO NEW WORK.
2. ITEMS SHOWN DASHED/HATCHED ARE TO BE REMOVED.
3. ALL BRANCH PIPING/DUCTWORK SHALL BE CAPPED AT
MAIN UNLESS OTHERWISE NOTED.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:0 :4
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MD100C-A1
H V
A C
D E
M O
LI
T
IO
N
P
LA
N L
O W
E R
L E
V E
L
A R
E A
C
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
MECHANICAL DEMOLITION PLAN - PHASE A1 LOWER LEVEL AREA C
REMOVE EXISTING HEATING HOT WATER PIPING SHOWN DASHED/BOLD. DO
NOT REMOVE UNTIL NEW PIPE IS INSTALLED DUE TO EXISTING COIL
CONNECTION PHASING.
REMOVE EXISTING OUTDOOR AIR SUPPLY FAN (SF-13) LOCATED IN LN44
EXHAUST CHAMBER AND REMOVE ALL ASSOCIATED DUCTWORK.
REMOVE EXISTING OUTDOOR AIR SUPPLY DUCT AND EXHAUST DUCT
SERVING SPACE AND BEYOND.
EXISTING SUPPLY RUNOUT PIPING SERVING REHEAT COIL TO REMAIN.
KEYED NOTES
5 REMOVE EXISTING TERMINAL COOLING UNIT AND ALL ASSOCIATED PIPING
AND CONDENSING UNIT.
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
E D C B A
TH-(E)
20 HR
20 HS
32 CS
125 HR
200 CR
32 CS 32
200 CR125 HR
125 HR
200 CR
EF-42
EXISTING DUCT MOUNTED HEATING
COIL
0x
0x
REMOVE EXISTING
OUTSIDE AIR
SUPPLY DUCT REMOVE EXISTING
EXHAUST AIR DUCT
HS
HS
HS
200ø
400x400
MATCH LINE
SEE MD101D-B1
M A
T C
H L
IN
E
S E
E M
D
C -A
GENERAL DEMO NOTES:
1. ALL ITEMS SHOWN ARE EXISTING. NOT ALL EXISTING
MECHANICAL EQUIPMENT, DUCTWORK, AND PIPING ARE
SHOWN FOR CLARITY. CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO NEW WORK.
2. ITEMS SHOWN DASHED/HATCHED ARE TO BE REMOVED.
3. ALL BRANCH PIPING/DUCTWORK SHALL BE CAPPED AT
MAIN UNLESS OTHERWISE NOTED.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:0 :5
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MD100E-A1
H V
A C
D E
M O
LI
T
IO
N
P
LA
N L
O W
E R
L E
V E
L
A R
E A
E
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
MECHANICAL DEMOLITION PLAN - PHASE A1 LOWER LEVEL AREA E
REMOVE EXISTING HEATING HOT WATER PIPING SHOWN BOLD AND
DASHED. DO NOT REMOVE UNTIL NEW PIPE IS INSTALLED DUE TO EXISTING
COIL CONNECTION PHASING.
REMOVE EXISTING EXHAUST FAN (EF-42) LOCATED IN EXHAUST CHAMBER
ROOM LN41 AND ALL ASSOCIATED DUCTWORK.
KEYED NOTES
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
LG22
LG22CLG22B
ATU-4-LG22
150ØD1
150ØD1
150ØD1
150ØD1
300ø SA
300x250 SA200ØD1
90150ØD1
150ØD1
ATU-4-LG22C
250x250 SA
200ø SA 250x200 RA
200ØG1
150ØG1
150x150 RA
LG22A
GENERAL NOTES:
1. NOT ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK,
AND PIPING SHOWN FOR CLARITY. CONTRACTOR TO
VERIFY EXISTING CONDITIONS PRIOR TO NEW WORK.
2. EXISTING DUCTWORK AND EQUIPMENT SHOWN AS HALF
TONE.
3. ALL BRANCH DUCTWORK TO DIFFUSER/GRILLES SHALL
MATCH NECK SIZE UNLESS OTHERWISE NOTED.
4. SEE PIPING PLAN FOR HVAC ZONES.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:0 :0
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MH100C-A1
H V
A C
P
LA
N L
O W
E R
L E
V E
L
A R
E A
C
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PLAN - PHASE A1 LOWER LEVEL AREA C
ROOM SCHEDULE LOWER LEVEL AREA C PHASE
A1
NUMBER NAME
LG01 STOR
LG02 VENDING
LG03 LINEN C. LINEN
LG04 LINEN S. LINEN
LG05 LINEN OFFICE/SUPPLY
LG06 BIO. MED. EQ. TECH SHOP
LG08 OFFICE
LG09 URGENT EXAM
LG10 URGENT EXAM
LG11 URGENT EXAM
LG12 URGENT MEDS
LG13 S. UTILITY
LG14 URGENT VITAL
LG15 URGENT WAITING
LG15A COMM
LG16 TLT
LG17 URGENT RECEPTION
LG17A STOR
LG18 JAN
LG19 TLT
LG20 URGENT TRIAGE
LG21 URGENT OFFICE
LG22 TEMPORARY KITCHEN SPACE
LG22A SUPPLY
LG22B OFFICE
LG22C LOUNGE
LG25 VEST
LG26 STORAGE
LG27 STORAGE
LG28 CORR
LGC3 CORR
LGC4 CORR
LGC4A CORR
LGC5 CORR
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
100 HR
80 HS
150 CR
125 CS
200 CR
32 CS
125 HR
125 HR
200 CR
125 HR
80 HS
50 HS
CAP PIPING FOR
CONNECTION IN
PHASE 2
ATU-4-LG22
80 GHS
100 HS
80 GHR
50 HS
40 HR
40 HS
ATU-4-LG22C
20 HR 20 HS
LG22
LG22CLG22B
LG22A
125 HR
EXISTING DUCT
MOUNTED
HEATING COIL
EXISTING DUCT
MOUNTED
HEATING COIL
EXISTING DUCT
MOUNTED
HEATING COIL
EXISTING DUCT
MOUNTED
HEATING COIL
MATCH LINE
SEE XMP100B-P1
M A
T C
H L
IN
E
S E
E M
P
E -A
GENERAL NOTES:
1. BOLD DASHED OUTLINE REPRESENTS HVAC ZONING.
2. NOT ALL EXISTING SHOWN CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO START OF NEW
WORK.
3. ALL HWS/R BRANCH PIPING SHALL BE 20MM UNLESS
OTHERWISE NOTED.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:0 :0
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MP100C-A1
H V
A C
P
IP
IN
G
P
LA
N L
O W
E R
L E
V E
L
A R
E A
C
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PIPING PLAN - PHASE A1 LOWER LEVEL AREA C
ROOM SCHEDULE LOWER LEVEL AREA C PHASE
A1
NUMBER NAME
LG01 STOR
LG02 VENDING
LG03 LINEN C. LINEN
LG04 LINEN S. LINEN
LG05 LINEN OFFICE/SUPPLY
LG06 BIO. MED. EQ. TECH SHOP
LG08 OFFICE
LG09 URGENT EXAM
LG10 URGENT EXAM
LG11 URGENT EXAM
LG12 URGENT MEDS
LG13 S. UTILITY
LG14 URGENT VITAL
LG15 URGENT WAITING
LG15A COMM
LG16 TLT
LG17 URGENT RECEPTION
LG17A STOR
LG18 JAN
LG19 TLT
LG20 URGENT TRIAGE
LG21 URGENT OFFICE
LG22 TEMPORARY KITCHEN SPACE
LG22A SUPPLY
LG22B OFFICE
LG22C LOUNGE
LG25 VEST
LG26 STORAGE
LG27 STORAGE
LG28 CORR
LGC3 CORR
LGC4 CORR
LGC4A CORR
LGC5 CORR
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
20 HR
25 CR
20 HS
25 CS
100 HR
80 HS
150 CR
125 CS
25 CS
25 CR
20 HS
20 HR
125 HR
200 CR
AHU-6
AHU-7
AHU-8
AHU-9
RF-8 (E)
RF-9 (E)
RF-6 (E)
RF-7 (E)
SF-10 (E)
50 HS
65 GHS
80 GHR
PH-8 (E)
PH-7 (E)
PH-6 (E)
PH-9 (E)
PROVIDE NEW HS
MAIN AS SHOWN
MATCH LINE
SEE MP100E-A1
M A
T C
H L
IN
E
S E
E X
M P
B
-P
GENERAL NOTES:
1. BOLD DASHED OUTLINE REPRESENTS HVAC ZONING.
2. NOT ALL EXISTING SHOWN CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO START OF NEW
WORK.
3. ALL HWS/R BRANCH PIPING SHALL BE 20MM UNLESS
OTHERWISE NOTED.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:0 :1
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MP100D-A1
H V
A C
P
IP
IN
G
P
LA
N L
O W
E R
L E
V E
L
A R
E A
D
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PIPING PLAN - PHASE A1 LOWER LEVEL AREA D
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
20 HR
20 HS
32 CS
125 HR
200 CR
32 CS
200 CR
125 HR
125 HR
200 CR
50 HS
50 HS
50 HS
EXISTING DUCT
MOUNTED
HEATING COIL
EXISTING WALL HEATER
PROVIDE NEW HS AS SHOWN
MATCH LINE
SEE MP100D-A1
M A
T C
H L
IN
E
S E
E M
P
C -A
GENERAL NOTES:
1. BOLD DASHED OUTLINE REPRESENTS HVAC ZONING.
2. NOT ALL EXISTING SHOWN CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO START OF NEW
WORK.
3. ALL HWS/R BRANCH PIPING SHALL BE 20MM UNLESS
OTHERWISE NOTED.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:0 :1
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MP100E-A1
H V
A C
P
IP
IN
G
P
LA
N L
O W
E R
L E
V E
L
A R
E A
E
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PIPING PLAN - PHASE A1 LOWER LEVEL AREA E
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
REMOVE EXISTING
EF-18 EXHAUST DUCT
200ø EA
350x300
250x250 EA
650x500 SA
550x500 RA
AHU-4
AHU-4
EF-11 EXHAUST DUCT TO REMAIN
EF-9 EXHAUST DUCT TO REMAIN
REMOVE EF-18
EXHAUST DUCT
EXISTING AHU-4
SUPPLY/RETURN AIR
TO REMAIN
350x300
350x300
150ø 300x300
100ø
200x200 SA
150ø
350x350 SA
0x
S A
0x
S A
150ø
150ø
M A
T C
H L
IN
E
S E
E M
D
E -A
M A
T C
H L
IN
E
S E
E M
D
A -C
REMOVE EXISTING SF-6
OUTSIDE AIR DUCT. CAP
AT MECHANICAL ROOM
250x250
250x250
MH507
GENERAL DEMO NOTES:
1. ALL ITEMS SHOWN ARE EXISTING. NOT ALL EXISTING
MECHANICAL EQUIPMENT, DUCTWORK, AND PIPING ARE
SHOWN FOR CLARITY. CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO NEW WORK.
2. ITEMS SHOWN DASHED/HATCHED ARE TO BE REMOVED.
3. ALL BRANCH PIPING/DUCTWORK SHALL BE CAPPED AT
MAIN UNLESS OTHERWISE NOTED.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :1
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MD100C-A2
H V
A C
D E
M O
LI
T
IO
N
P
LA
N L
O W
E R
L E
V E
L
A R
E A
C
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC DEMOLITION PLAN - PHASE A2 LOWER LEVEL AREA C
REMOVE EXISTING EF-18 EXHAUST DUCT
REMOVE EXISTING FILTERED DIFFUSER UNIT,
ASSOCIATED INLINE FAN, VAV BOX, AND ALL
ASSOCIATED SUPPLY DUCTWORK.
REMOVE EXISTING VAV BOX.
REMOVE EXISTING SUPPLY AIR RUNOUTS AND
DIFFUSERS WITHOUT UPSTREAM VAV BOX.
KEYED NOTES
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
REMOVE EXISTING
EF-18 EXHAUST DUCTWORK
175ø EA
450x450 SA
400x350 RA
EF-11
EXHAUST
DUCT TO
REMAIN
REMOVE EF-18
EXHAUST DUCT
AHU-4
SUPPLY
DUCT
EF-9 EXHAUST DUCT
TO REMAIN
AHU-4 RETURN DUCT
200ø SA
200ø
150ø
200ø
200ø175ø
300x250 SA
200x200
125ø
150ø
100ø
175ø
200x200
300x250
250x250
150ø
350x300
175ø
100ø
175ø
200x200
125ø
300x250 SA
100ø
200x200
250x200
M A
T C
H L
IN
E
S E
E M
D
C -A
REMOVE EXISTING
SF-6 OUTSIDE AIR DUCTWORK
GENERAL DEMO NOTES:
1. ALL ITEMS SHOWN ARE EXISTING. NOT ALL EXISTING
MECHANICAL EQUIPMENT, DUCTWORK, AND PIPING ARE
SHOWN FOR CLARITY. CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO NEW WORK.
2. ITEMS SHOWN DASHED/HATCHED ARE TO BE REMOVED.
3. ALL BRANCH PIPING/DUCTWORK SHALL BE CAPPED AT
MAIN UNLESS OTHERWISE NOTED.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :2
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MD100E-A2
H V
A C
D E
M O
LI
T
IO
N
P
LA
N L
O W
E R
L E
V E
L
A R
E A
E
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC DEMOLITION PLAN - PHASE A2 LOWER LEVEL AREA E
REMOVE EXISTING TERMINAL COOLING UNIT AND
ALL ASSOCIATED PIPING AND CONDENSING UNIT.
REMOVE EXISTING VAV BOX.
REMOVE EXISTING SUPPLY AIR RUNOUTS AND
DIFFUSER WITHOUT UPSTREAM VAV BOX.
REMOVE EXISTING EF-18 EXHAUST DUCT.
REMOVE EXISTING VAV BOX, REHEAT COIL, AND
SUPPLY DUCT ASSOCIATED WITH NUTRITIONAL
MEDICINE DEPARTMENT.
REMOVE EXISTING EXHAUST BRANCH AND GRILLE
FROM EXISTING EF-11. CAP AT MAIN.
KEYED NOTES
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
R P N M L
MD401-A2
MH507
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
1 : 100
/1
/2
:1 :3
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MD101A-A2
H V
A C
P
IP
IN
G
D E
M O
LI
T
IO
N
P
LA
N L
O W
E R
L E
V E
L
A R
E A
A
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PIPING DEMOLITION PLAN - PHASE A2 LOWER LEVEL AREA A
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
REMOVE EXISTING HS/HR
PIPING SERVING EXISTING
DUCT MOUNTED REHEAT COIL
BACK TO MAIN AND CAP.
H
R
H S
32 CS
50 HS
200 CR
125 HR
REMOVE EXISTING
REHEAT COIL
REMOVE EXISTING
TERMINAL COOLING
UNIT AND ALL
ASSOCIATED PIPING
AND CONDENSING UNIT
GENERAL DEMO NOTES:
1. ALL ITEMS SHOWN ARE EXISTING. NOT ALL EXISTING
MECHANICAL EQUIPMENT, DUCTWORK, AND PIPING ARE
SHOWN FOR CLARITY. CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO NEW WORK.
2. ITEMS SHOWN DASHED/HATCHED ARE TO BE REMOVED.
3. ALL BRANCH PIPING/DUCTWORK SHALL BE CAPPED AT
MAIN UNLESS OTHERWISE NOTED.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :3
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MD110E-A2
H V
A C
P
IP
IN
G
D E
M O
LI
T
IO
N
P
LA
N L
O W
E R
L E
V E
L
A R
E A
E
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PIPING DEMOLITION PLAN - PHASE A2 LOWER LEVEL AREA E
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
M
M
M
S R P N M L
MH401-A2
M A
T C
H L
IN
E
S E
E M
H
C -A
P
P
LOCATE ABOVE GARAGE
DOOR IN AMBULANCE DRIVE
TUNNEL
MH507
GENERAL NOTES:
1. NOT ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK,
AND PIPING SHOWN FOR CLARITY. CONTRACTOR TO
VERIFY EXISTING CONDITIONS PRIOR TO NEW WORK.
2. EXISTING DUCTWORK AND EQUIPMENT SHOWN AS HALF
TONE.
3. ALL BRANCH DUCTWORK TO DIFFUSER/GRILLES SHALL
MATCH NECK SIZE UNLESS OTHERWISE NOTED.
4. SEE PIPING PLAN FOR HVAC ZONES.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :4
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MH100A-A2
H V
A C
P
LA
N L
O W
E R
L E
V E
L
A R
E A
A
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PLAN - PHASE A2 LOWER LEVEL AREA A 1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
K J H G F
LG08
LG06
LGC3
LG02 LG01
LG03
LG05
LG04
LG22BLG22A
LGC4A
LG22C
LG22
650x500 SA
550x500 RA
450x450 SA
450x450 RA
ATU-4-LG06
ATU-4-LG02
ATU-4-LG05
AHU-4 RA DUCT
AHU-4 SA DUCT
200ø EA
EF-11
EF-9
250x250 EA
150ØD1
150ØG1
200x150 SA
150ØD1
150ø RA
(E)
(TYP. 3)
(E)
200ø SA
150ø SA
150ØD1
150ØD1
150ØD1
(E)
(E)
150ØD1
(E)
(E)
300x200 SA
LHC1
(E)
(E)
200ø SA
150ø SA
150ø SA
200ØG1
200x150 RA
(E)
300ø SA
M A
T C
H L
IN
E
S E
E M
H
E -A
M A
T C
H L
IN
E
S E
E M
H
A -A
MH507
GENERAL NOTES:
1. NOT ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK,
AND PIPING SHOWN FOR CLARITY. CONTRACTOR TO
VERIFY EXISTING CONDITIONS PRIOR TO NEW WORK.
2. EXISTING DUCTWORK AND EQUIPMENT SHOWN AS HALF
TONE.
3. ALL BRANCH DUCTWORK TO DIFFUSER/GRILLES SHALL
MATCH NECK SIZE UNLESS OTHERWISE NOTED.
4. SEE PIPING PLAN FOR HVAC ZONES.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :4
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MH100C-A2
H V
A C
P
LA
N L
O W
E R
L E
V E
L
A R
E A
C
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PLAN - PHASE A2 LOWER LEVEL AREA C
ENTIRE AHU-4 SUPPLY AND RETURN AIR SYSTEM TO
BE MODIFIED TO MEET UFC STANDARDS. THIS
WORK INCLUDES REPLACING ALL VAV BOXES WITH
HOT WATER REHEAT VAV BOXES, PROVIDING VAV
BOXES WHERE DIFFUSERS CURRENTLY DO NOT
HAVE AN UPSTREAM VAV BOX, AND REMOVING
INLINE SUPPLY FANS WITH FINAL FILTERS. BALANCE
EXISTING DIFFUSERS TO PRE-CONSTRUCTION TEST
AND BALANCE AIRFLOWS UNLESS OTHERWISE
NOTED.
PROVIDE VOLUME DAMPER IN EXISTING BRANCH
DUCTWORK. IF EXISTING DAMPER IS PRESENT,
EXISTING TO REMAIN.
KEYED NOTES
ROOM SCHEDULE LOWER LEVEL AREA C
PHASE A2
NUMBER NAME
LG01 STOR
LG02 VENDING
LG03 LINEN C. LINEN
LG04 LINEN S. LINEN
LG05 LINEN OFFICE/SUPPLY
LG06 BIO. MED. EQ. TECH SHOP
LG08 OFFICE
LG09 URGENT EXAM
LG10 URGENT EXAM
LG11 URGENT EXAM
LG12 URGENT MEDS
LG13 S. UTILITY
LG14 URGENT VITAL
LG15 URGENT WAITING
LG15A COMM
LG16 TLT
LG17 URGENT RECEPTION
LG17A STOR
LG18 JAN
LG19 TLT
LG20 URGENT TRIAGE
LG21 URGENT OFFICE
LG22A SUPPLY
LG22B OFFICE
LG22C LOUNGE
LG23 STOR
LG24 VEST
LG25 VEST
LG26 STORAGE
LG27 STORAGE
LG28 CORR
LG29 STOR
LG30 STORM WATER PUMP ROOM
LG31 MECH
LGC3 CORR
LGC4 CORR
LGC4A CORR
LGC5 CORR
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
LH19
LH16
LH15
LH31
LH29A
LH29
LH30
LH28
LG23
LG24
LH27
LH26
LH25
LHC1
LH14
LH19C
LH19B
L-STAIR
E
LE26
LE25
LH22
LHC2
LH13
ATU-4-LH30 ATU-4-LH29A
ATU-4-LH26
ATU-4-LH13
ATU-4-LH28
ATU-4-LH22
ATU-4-LH14
450x450 SA
400x350 RA
450x400 SA
350x300 RA350x350 RA 250x250 RA
150ØD1
175ø SA
(E)
(E)
(E)
(E)
250ØG1
250x200 RA
(E)150ØD1
250x250 SA
200x200 SA
150ØD1
ATU-4-LH19
(TYP. 4)
150ØD1
LHC1
250ø SA 250x250 RA
300ØG1
200ø SA
200x200 SA
150ØD1
150ØD1
150ØD1
150Ø(E)
(E)
(E)
(E)
(E)
150ØD1
250ø SA
250x250 SA
(TYP. 3)
250x250 SA
150ØD1
150ØD1
(E)
(E)
(E)
(E)
(E)
M A
T C
H L
IN
E
S E
E M
H
C -A
D1
D1
GENERAL NOTES:
1. NOT ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK,
AND PIPING SHOWN FOR CLARITY. CONTRACTOR TO
VERIFY EXISTING CONDITIONS PRIOR TO NEW WORK.
2. EXISTING DUCTWORK AND EQUIPMENT SHOWN AS HALF
TONE.
3. ALL BRANCH DUCTWORK TO DIFFUSER/GRILLES SHALL
MATCH NECK SIZE UNLESS OTHERWISE NOTED.
4. SEE PIPING PLAN FOR HVAC ZONES.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :5
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MH100E-A2
H V
A C
P
LA
N L
O W
E R
L E
V E
L
A R
E A
E
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PLAN - PHASE A2 LOWER LEVEL AREA E
ENTIRE AHU-4 SUPPLY AND RETURN AIR SYSTEM TO
BE MODIFIED TO MEET UFC STANDARDS. THIS
WORK INCLUDES REPLACING ALL VAV BOXES WITH
HOT WATER REHEAT VAV BOXES, PROVIDING VAV
BOXES WHERE DIFFUSERS CURRENTLY DO NOT
HAVE AN UPSTREAM VAV BOX, AND REMOVING
INLINE SUPPLY FANS WITH FINAL FILTERS.
INSTALL DUCT STATIC PRESSURE SENSOR IN
EXISTING SUPPLY MAIN.
PROVIDE VOLUME DAMPER IN EXISTING BRANCH
DUCTWORK. IF EXISTING DAMPER IS PRESENT,
EXISTING TO REMAIN.
KEYED NOTES
ROOM SCHEDULE LOWER
LEVEL AREA E - PHASE A2 - LH
NUMBER NAME
LH01 GAS STOR
LH02 GAS STOR
LH02A GAS STOR
LH04 ELEC
LH05 STOR
LH06 LOUNGE
LH07 M/TLT
LH08 F/TLT
LH09 MORGUE
LH10 TRASH
LH11 LOADING DOCK
LH12 CORR
LH13 CORR
LH14 OFFICE
LH15 OFFICE
LH16 OFFICE
LH19 KITCHEN SPACE
LH19A CUBICLE
LH19B CUBICLE
LH19C CUBICLE
LH21 TRAY DROP OFF
LH22 OFFICE, CONSULT
LH25 ELEC
LH26 OFFICE
LH27 TLT
LH28 HOUSEKEEPING
LH29 FACILITIES OFFICE
LH29A FACILITIES OFFICE
LH30 FACILITIES OFFICE
LH31 MECH
LHC1 CORR
LHC2 CORR
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
S R P N M L
EXISTING HEATING
HOT WATER PUMPS
EXISTING HEATING HOT
WATER HEAT EXCHANGER
(STEAM TO HHW)
EXISTING HEATING HOT
WATER HEADER (RETURN)
EXISTING HEATING
HOT WATER
HEADER (SUPPLY)
100 HWS/R UP TO DENTAL
AREA MECH ROOM
150 CWS/R UP TO DENTAL
AREA MECH ROOM
125 CS
150 CR
125 CS
150 CR
LPC UP
LPS UP
EXISTING
CLEAN STEAM
GENERATOR
EXISTING STEAM
CONDENSATE PUMP
EXISTING STEAM
CONDENSATE TANK
EXISTING LOW PRESSURE
STEAM CONDENSATE PIPING
EXISTING CLEAN STEAM PIPING
80 GHS/R UP TO DENTAL
AREA MECH ROOM
MH401-A2
M A
T C
H L
IN
E
S E
E M
P
C -A
MH507
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
1 : 100
/1
/2
:1 :0
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MP100A-A2
H V
A C
P
IP
IN
G
P
LA
N L
O W
E R
L E
V E
L
A R
E A
A
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PIPING PLAN - PHASE A2 LOWER LEVEL AREA A 1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
100 HR
80 HS
150 CR
200 CR
32 CS
125 HR
125 HR
200 CR
125 HR
80 HS
ATU-4-LG06
ATU-4-LG02
ATU-4-LG05
32 HR
32 HS
32 HR
32 HS
H
S
H R
50 HS
20 HS
20 HR
ATU-4-LG22C
LG04
LG05
LG06
LG08
LG22BLG22A
LG22C LG22
LHC1
LG02
LG01
20 HR
20 HS
M A
T C
H L
IN
E
S E
E M
P
E -A
M A
T C
H L
IN
E
S E
E M
P
A -A
MH507
GENERAL NOTES:
1. BOLD DASHED OUTLINE REPRESENTS HVAC ZONING.
2. NOT ALL EXISTING SHOWN CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO START OF NEW
WORK.
3. ALL HWS/R BRANCH PIPING SHALL BE 20MM UNLESS
OTHERWISE NOTED.
L K J H G F
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :0
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MP100C-A2
H V
A C
P
IP
IN
G
P
LA
N L
O W
E R
L E
V E
L
A R
E A
C
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PIPING PLAN - PHASE A2 LOWER LEVEL AREA C
ENTIRE AHU-4 SUPPLY AND RETURN AIR SYSTEM TO
BE MODIFIED TO MEET UFC STANDARDS. THIS
WORK INCLUDES REPLACING ALL VAV BOXES WITH
HOT WATER REHEAT VAV BOXES, PROVIDING VAV
BOXES WHERE DIFFUSERS CURRENTLY DO NOT
HAVE AN UPSTREAM VAV BOX, AND REMOVING
INLINE SUPPLY FANS WITH FINAL FILTERS.
KEYED NOTES
ROOM SCHEDULE GROUND LEVEL AREA C
PHASE A2
NUMBER NAME
LG01 STOR
LG02 VENDING
LG03 LINEN C. LINEN
LG04 LINEN S. LINEN
LG05 LINEN OFFICE/SUPPLY
LG06 BIO. MED. EQ. TECH SHOP
LG08 OFFICE
LG09 URGENT EXAM
LG10 URGENT EXAM
LG11 URGENT EXAM
LG12 URGENT MEDS
LG13 S. UTILITY
LG14 URGENT VITAL
LG15 URGENT WAITING
LG15A COMM
LG16 TLT
LG17 URGENT RECEPTION
LG17A STOR
LG18 JAN
LG19 TLT
LG20 URGENT TRIAGE
LG21 URGENT OFFICE
LG22A SUPPLY
LG22B OFFICE
LG22C LOUNGE
LG23 STOR
LG24 VEST
LG25 VEST
LG26 STORAGE
LG27 STORAGE
LG28 CORR
LG29 STOR
LG30 STORM WATER PUMP ROOM
LG31 MECH
LGC3 CORR
LGC4 CORR
LGC4A CORR
LGC5 CORR
1m
SCALE: 1:100
0 4m2m1m
NEW CATWALK, SEE ARCHITECTURAL PLANS FOR DETAILS
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
200 CR
20 HR
20 HS
32 CS
125 HR
200 CR
32 CS
200 CR125 HR
125 HR
200 CR
LH19
LH22
LH14
LH16 LH15
ATU-4-LH30 ATU-4-LH29A ATU-4-LH28
ATU-4-LH26
ATU-4-LH13
ATU-4-LH14
ATU-4-LH22
ATU-4-LH19
LH19A LH19B LH19C
LHC1
LH28
LH29
LH29A
LH30
LG23
LH27
LH26
LH25
LHC2
LH13
32 HR
32 HS
32 HR
32 HS 25 HS
25 HR
20 HS
20 HR
H
S
H
R
M A
T C
H L
IN
E
S E
E M
P
C -A
GENERAL NOTES:
1. BOLD DASHED OUTLINE REPRESENTS HVAC ZONING.
2. NOT ALL EXISTING SHOWN CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO START OF NEW
WORK.
3. ALL HWS/R BRANCH PIPING SHALL BE 20MM UNLESS
OTHERWISE NOTED.
E D C B A
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :1
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MP100E-A2
H V
A C
P
IP
IN
G
P
LA
N L
O W
E R
L E
V E
L
A R
E A
E
P H
A S
E A
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PIPING PLAN - PHASE A2 LOWER LEVEL AREA E
ENTIRE AHU-4 SUPPLY AND RETURN AIR SYSTEM TO
BE MODIFIED TO MEET UFC STANDARDS. THIS
WORK INCLUDES REPLACING ALL VAV BOXES WITH
HOT WATER REHEAT VAV BOXES, PROVIDING VAV
BOXES WHERE DIFFUSERS CURRENTLY DO NOT
HAVE AN UPSTREAM VAV BOX, AND REMOVING
INLINE SUPPLY FANS WITH FINAL FILTERS.
KEYED NOTES
ROOM SCHEDULE GROUND LEVEL
AREA E PHASE A2
NUMBER NAME
LH01 GAS STOR
LH02 GAS STOR
LH02A GAS STOR
LH04 ELEC
LH05 STOR
LH06 LOUNGE
LH07 M/TLT
LH08 F/TLT
LH09 MORGUE
LH10 TRASH
LH11 LOADING DOCK
LH12 CORR
LH13 CORR
LH14 OFFICE
LH15 OFFICE
LH16 OFFICE
LH19 KITCHEN SPACE
LH19A CUBICLE
LH19B CUBICLE
LH19C CUBICLE
LH21 TRAY DROP OFF
LH22 OFFICE, CONSULT
LH25 ELEC
LH26 OFFICE
LH27 TLT
LH28 HOUSEKEEPING
LH29 FACILITIES OFFICE
LH29A FACILITIES OFFICE
LH30 FACILITIES OFFICE
LH31 MECH
LHC1 CORR
LHC2 CORR
1m
SCALE: 1:100
0 4m2m1m
NEW CATWALK, SEE
ARCHITECTURAL
PLANS FOR DETAILS
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
AHU-9 (E)
AHU-8 (E)
AHU-7 (E)
150ø
150ø
250x200
250x200
0x
S A
ATU-(E)
GENERAL DEMO NOTES:
1. ALL ITEMS SHOWN ARE EXISTING. NOT ALL EXISTING
MECHANICAL EQUIPMENT, DUCTWORK, AND PIPING ARE
SHOWN FOR CLARITY. CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO NEW WORK.
2. ITEMS SHOWN DASHED/HATCHED ARE TO BE REMOVED.
3. ALL BRANCH PIPING/DUCTWORK SHALL BE CAPPED AT
MAIN UNLESS OTHERWISE NOTED.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :2
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MD101D-B1
H V
A C
D E
M O
LI
T
IO
N
P
LA
N P
LA
N
L O
W E
R L
E V
E L
A
R E
A B
P
H A
S E
B
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
MECHANICAL DEMOLITION PLAN - PHASE 1 LOWER LEVEL AREA D 1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
200ØD1
300x150R1
250ØG1
250ØG1
AHU-9 (E)
AHU-8 (E)
AHU-6
AHU-7 (E)
(E)
(E)100
(E) (E)
DUCTWORK MODIFIED
TO ACCOMMODATE NEW
MECHANICAL ROOM
EXISTING
TERMINAL
UNIT (LD23)
GENERAL NOTES:
1. NOT ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK,
AND PIPING SHOWN FOR CLARITY. CONTRACTOR TO
VERIFY EXISTING CONDITIONS PRIOR TO NEW WORK.
2. EXISTING DUCTWORK AND EQUIPMENT SHOWN AS HALF
TONE.
3. ALL BRANCH DUCTWORK TO DIFFUSER/GRILLES SHALL
MATCH NECK SIZE UNLESS OTHERWISE NOTED.
4. SEE PIPING PLAN FOR HVAC ZONES.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :5
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MH100D-B1
H V
A C
P
LA
N L
O W
E R
L E
V E
L
A R
E A
D
P H
A S
E B
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PLAN - PHASE B1 LOWER LEVEL AREA D 1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
EXISTING AHU-6
SUPPLY AIR DUCT
REMOVE EXISTING EXHAUST
DUCT ASSOCIATED WITH
EF-37
EXISTING EF-33
EXHAUST AIR DUCT
EXISTING AHU-6
RETURN AIR DUCT
EXISTING AHU-6
SUPPLY AIR DUCT
REMOVE EXISTING
EXHAUST DUCT
EXISTING EXHAUST AIR
DUCT TO REMAIN
200ø
200ø
125ø
125ø
150ø
175ø
200ø
200ø
150ø 200ø
250x200
175ø
125ø
200ø
175ø
150ø
175ø 100ø
100ø
125ø
150ø
152ø
M A
T C
H L
IN
E
S E
E M
D
D -B
MH507
MH507
MH507
GENERAL DEMO NOTES:
1. ALL ITEMS SHOWN ARE EXISTING. NOT ALL EXISTING
MECHANICAL EQUIPMENT, DUCTWORK, AND PIPING ARE
SHOWN FOR CLARITY. CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO NEW WORK.
2. ITEMS SHOWN DASHED/HATCHED ARE TO BE REMOVED.
3. ALL BRANCH PIPING/DUCTWORK SHALL BE CAPPED AT
MAIN UNLESS OTHERWISE NOTED.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :0
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MD100B-B2
H V
A C
D E
M O
LI
T
IO
N
P
LA
N L
O W
E R
L E
V E
L
A R
E A
B
P H
A S
E B
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC DEMOLITION PLAN - PHASE B2 LOWER LEVEL AREA B
KEYED NOTES
REMOVE EXISTING SUPPLY AIR RUNOUTS AND
DIFFUSER WITHOUT EXISTING UPSTREAM VAV BOX.
REMOVE EXISTING DUCT MOUNTED HOT WATER
REHEAT COIL.
REMOVE EXISTING VAV BOX.
REMOVE EXISTING FILTERED DIFFUSER UNIT,
ASSOCIATED INLINE FAN, VAV BOX, AND ALL
ASSOCIATED SUPPLY DUCTWORK.
REMOVE EXHAUST DUCTWORK BRANCHES FROM EF-22
TO DAMPERS LOCATED AT WALL.
REMOVE EXISTING EXHAUST AND INLINE FAN, SPACE
NOT REQUIRED TO BE EXHAUSTED.
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
AHU-6 SUPPLY
DUCTWORK
TO REMAIN
AHU-6 RETURN
DUCTWORK TO REMAIN
REMOVE EXISTING EF-32
EXHAUST AIR DUCT
REMOVE EXISTING EXHAUST
DUCT ASSOCIATED WITH EF-37
EXISTING EXHAUST
AIR DUCT TO REMAIN
REMOVE EXISTING EF-32 EXHAUST AIR DUCT
EXISTING AHU-6
RETURN AIR DUCT
EXISTING AHU-6
SUPPLY AIR DUCT
EXISTING AHU-6 SUPPLY AIR
DUCT TO REMAIN
REMOVE EXISTING EXHAUST
DUCT ASSOCIATED WITH EF-37
EXISTING EF-33 EXHAUST AIR DUCT
TO REMAIN
200ø
200ø
250x200
200ø
200ø
200ø
250x200
150ø
175ø
200ø
300x250
500x400550x350
0x
0x
200ø
350x300
350x300
250x200
200ø
0x
200ø
200ø
200ø
150ø
150ø
250x200
100ø
0x
250ø
350x300
450x300
200ø
125ø
250x250 125ø
200ø
175ø
200x150
200ø
150ø
350x300
200ø
200ø
150ø
150ø
200ø
100ø
125ø
MD402-B2
M A
T C
H L
IN
E
S E
E M
D
B -B
MH507
MH507
GENERAL DEMO NOTES:
1. ALL ITEMS SHOWN ARE EXISTING. NOT ALL EXISTING
MECHANICAL EQUIPMENT, DUCTWORK, AND PIPING ARE
SHOWN FOR CLARITY. CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO NEW WORK.
2. ITEMS SHOWN DASHED/HATCHED ARE TO BE REMOVED.
3. ALL BRANCH PIPING/DUCTWORK SHALL BE CAPPED AT
MAIN UNLESS OTHERWISE NOTED.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :1
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MD100D-B2
H V
A C
D E
M O
LI
T
IO
N
P
LA
N L
O W
E R
L E
V E
L
A R
E A
D
P H
A S
E B
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC DEMOLITION PLAN - PHASE B2 LOWER LEVEL AREA D
KEYED NOTES
REMOVE EXISTING SUPPLY AIR RUNOUTS AND
DIFFUSER WITHOUT UPSTREAM VAV BOX.
REMOVE EXISTING DUCT MOUNTED HOT WATER
REHEAT COIL.
REMOVE EXISTING VAV BOX.
REMOVE EXISTING FILTERED DIFFUSER UNIT,
ASSOCIATED INLINE FAN, VAV BOX, AND ALL
ASSOCIATED SUPPLY DUCTWORK.
REMOVE DUCTWORK SERVING EXISTING SPD AS
SHOWN.
REMOVE EXISTING EF-37 DUCTWORK
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
REMOVE EXISTING HS/HR PIPING
SERVING DUCT MOUNTED REHEAT
COIL. CAP AT MAIN.
H R
H
S
C
R
C
S
C S
C R
H
S
H
R
100 HR
80 HS
150 CR
125 CS
REMOVE EXISTING
REHEAT COIL
M A
T C
H L
IN
E
S E
E M
D
D -B
MH507
MH507
MH507
GENERAL DEMO NOTES:
1. ALL ITEMS SHOWN ARE EXISTING. NOT ALL EXISTING
MECHANICAL EQUIPMENT, DUCTWORK, AND PIPING ARE
SHOWN FOR CLARITY. CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO NEW WORK.
2. ITEMS SHOWN DASHED/HATCHED ARE TO BE REMOVED.
3. ALL BRANCH PIPING/DUCTWORK SHALL BE CAPPED AT
MAIN UNLESS OTHERWISE NOTED.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :2
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MD110B-B2
H V
A C
P
IP
IN
G
D E
M O
LI
T
IO
N
L O
W E
R L
E V
E L
A
R E
A B
P
H A
S E
B
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PIPING DEMOLITION PLAN - PHASE B2 LOWER LEVEL AREA B
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
REMOVE EXISTING HS/HR AND CS/CR
SERVING DUCT MOUNTED COILS AND CAP
AT MAIN
H R
H
S
C
R
C
S
100 HR
80 HS
150 CR
125 CS
C
S
C
R
H
S
H
R
80 GHR
65 GHS
REMOVE EXISTING (4) PIPE
HEATING AND COOLING COIL
REMOVE EXISTING
REHEAT COIL
MD402-B2
REMOVE EXISTING 80MM HPS AND 30
MM HPC IN CRAWL SPACE BELOW SPD
BACK TO INDICATED LOCATION.
32 HPC
80 HPS
M A
T C
H L
IN
E
S E
E M
D
B -B
MH507
MH507
GENERAL DEMO NOTES:
1. ALL ITEMS SHOWN ARE EXISTING. NOT ALL EXISTING
MECHANICAL EQUIPMENT, DUCTWORK, AND PIPING ARE
SHOWN FOR CLARITY. CONTRACTOR TO VERIFY
EXISTING CONDITIONS PRIOR TO NEW WORK.
2. ITEMS SHOWN DASHED/HATCHED ARE TO BE REMOVED.
3. ALL BRANCH PIPING/DUCTWORK SHALL BE CAPPED AT
MAIN UNLESS OTHERWISE NOTED.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :3
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MD110D-B2
H V
A C
P
IP
IN
G
D E
M O
LI
T
IO
N
L O
W E
R L
E V
E L
A
R E
A D
P
H A
S E
B
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PIPING DEMOLITION PLAN - PHASE B2 LOWER LEVEL AREA D
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
K J H G F
LB05
LB07
LB06
LB08
LBC1
LB32
LB33
LB24
LB31
LBC4
LB28
LB29
LB21
LB18
LB17
LB20LB23
LB25 LB11
LB14
LB13
LB15
LB26
ATU-6-LB05
ATU-6-LB31
ATU-6-LB26
ATU-6-LB25
ATU-6-LB21
ATU-6-LB15
ATU-6-LB11
ATU-6-LB33
CAP
LBC3
150ØD1
150ØD1
150ØG1
200ØD1
150ØD1
150ØD1
150ØD1
300ø SA
300x200 SA
200x200 SA
250x200 SA47 (E)
(E)
(E)
150ØD1
150ØD1
200ØD1
200ØG1
150ØD1
150x150 SA
150ø SA
200ØD1
(E)
200ø SA
(E)
(E)
(E)
250x200 SA
150ØD1
38 38
(E)
(E)
(E)
200ø SA
250ØD1
(E)
(E)
(E)
100ø EA 100ø EA
(E)
(E)
(E)
(E)
(E)
150ØD1
150ØD1
200ø SA
200x200 SA
250x250 SA
(E)
(E)
(E)
200x200 SA
(E)
M A
T C
H L
IN
E
S E
E M
H
D -B
MH507
MH507
MH507
GENERAL NOTES:
1. NOT ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK,
AND PIPING SHOWN FOR CLARITY. CONTRACTOR TO
VERIFY EXISTING CONDITIONS PRIOR TO NEW WORK.
2. EXISTING DUCTWORK AND EQUIPMENT SHOWN AS HALF
TONE.
3. ALL BRANCH DUCTWORK TO DIFFUSER/GRILLES SHALL
MATCH NECK SIZE UNLESS OTHERWISE NOTED.
4. SEE PIPING PLAN FOR HVAC ZONES.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :5
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MH100B-B2
H V
A C
P
LA
N L
O W
E R
L E
V E
L
A R
E A
B
P H
A S
E B
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PLAN - PHASE B2 LOWER LEVEL AREA B
ENTIRE AHU-6 SUPPLY AND RETURN AIR SYSTEM TO
BE MODIFIED TO MEET UFC STANDARDS. THIS
WORK INCLUDES REPLACING ALL VAV BOXES WITH
HOT WATER REHEAT VAV BOXES, PROVIDING VAV
BOXES WHERE DIFFUSERS CURRENTLY DO NOT
HAVE AN UPSTREAM VAV BOX, AND REMOVING
INLINE SUPPLY FANS WITH FINAL FILTERS.\
PROVIDE VOLUME DAMPER IN EXISTING BRANCH
DUCTWORK. IF EXISTING DAMPER IS PRESENT,
EXISTING TO REMAIN.
KEYED NOTES
ROOM SCHEDULE LOWER
LEVEL AREA B - LB
NUMBER NAME
LB01 OR 1
LB02 CENT STERILE
LB03 SCRUB
LB04 OR 2
LB05 RECOVERY
LB06 TLT
LB07 NURSE STAT
LB08 OFFICE
LB09 VEST
LB10 ELEC
LB11 NURSE STAT
LB12 CORR
LB13 ALCOVE
LB14 JAN
LB15 OFFICE
LB17 CORR
LB18 M/LOCKER
LB20 M/TLT
LB21 F/LOCKER
LB23 F/TLT
LB24 OFFICE
LB25 LOUNGE
LB26 SOILED
LB27 DICTATE
LB28 EQPM STOR
LB29 ELEC
LB30 ALCOVE
LB31 ANESTH WKRM
LB32 STOR
LB33 BREAK RM
LBC1 CORR
LBC2 CORR
LBC3 CORR
LBC4 CORR
1m
SCALE: 1:100
0 4m2m1m
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
LA11
LA12
LA42
LA44
LA45
LA39
LAC1
LA07
LA06
MH402-B2
LB12
LBC2
LA46
STAIR-A
LA30
LA37
LA35 LA36 LA33
LA32
LA34
LA29
LA28
LAC2
LA01
LA14
LA19
LA16
LA15
LAC2
LAC3
LAC5
LA21 LA22
LA23
LA27
LAC4
LA26
LDC1
LA47
LA13
LA18
ATU-6-LA29
ATU-6-LA07
ATU-6-LA44
ATU-6-LA35
ATU-6-LA21
ATU-6-LA19
ATU-6-LA14
ATU-6-LA26
CANOPY
EXHAUST
HOOD
CANOPY
EXHAUST HOOD
CAP
250ØD1
(TYP. 3)
150ØD1
(TYP. 2)
200ØG1
150ØG1
150ØD1
200ØD1
(TYP. 3)
350x350 EA
250ØG1
200ØD1
200ØD1
150ØD1
300x250 SA
200x200 SA
350x200 SA
200x200 SA
300ø SA
200ø SA
(E)
150ØD1
150ØD1
100ø EA 100ø EA
(E)
250ØD1
150ØD1
250x250 SA
150ØD1
250ø SA
150ø SA
200x150 SA
150ØD1
150ØD1
(E)
150ØD1
150ØD1
(E)
(E)
(E)
200ø SA
200x200 SA
200ø SA
150ØD1
150ØD1
200x200 SA
200ø SA
(E)
150ØD1
150ØD1
(E)
(E)
200ØD1
250ø SA
150ØD1
250x200 SA
200x150 SA
(E)
LA41
250x250 SA 200x200 SA
250ø SA
350x250 EA
250x250 EA
250x200 EA
400x250 EA
250x250 SA400x300 SA
125ø SA 125ØD1
350ø SA
400Ø
400x400 SA 250ø SA
350ø SA
750x500 SA550x500 SA500x450 SA
0x
S A
0x
S A x5
S A
(E)
(E)
(E)
ATU-6-LA39
ATU-6-LA42
(E)
300x250 EA
450x350 EA
M A
T C
H L
IN
E
S E
E M
H
B -B
MH507
MH507
10 (TYP.)
GENERAL NOTES:
1. NOT ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK,
AND PIPING SHOWN FOR CLARITY. CONTRACTOR TO
VERIFY EXISTING CONDITIONS PRIOR TO NEW WORK.
2. EXISTING DUCTWORK AND EQUIPMENT SHOWN AS HALF
TONE.
3. ALL BRANCH DUCTWORK TO DIFFUSER/GRILLES SHALL
MATCH NECK SIZE UNLESS OTHERWISE NOTED.
4. SEE PIPING PLAN FOR HVAC ZONES.
N
TRUE
NORTH
EPROJECT NO.:
CONSTR. CONTR. NO.
DRAWING NO.
SCALE:
SHEET OF
D E
P A
R T
M E
N T
O F
T H
E A
IR
F
O R
C E
A F
M S
A H
E A
L T
H F
A C
IL
IT
IE
S
D
IV
IS
IO
N
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
P A
C
IF
IC
A
IR
F O
R C
E C
IV
IL
E N
G
IN
E E
R C
E N
T E
R
DES
SUBMITTAL DATE
DRW CHK
ACTIVITY
FOR COMMANDER AFCEC
APPROVED
D D
C
B
A
54321
A
C
1 2 3 4 5
B
DRAWFORM
REVISION:
P L A N N I N G
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
EST. 1915
IF SHEET MEASURES LESS THAN 594 X 841 mm. IT IS A
REDUCED SIZE PRINT. REDUCE SCALE ACCORDINGLY
A/E INFO
SEAL
FA8903-15-D-0004 TO: 18-F-0072
APPROVED BY
23 DECEMBER 2019
KEY PLAN
A C
B D
E
L E
G A
C Y
P R
O J
E C
T
Q K
K A
O
P P
O R
T U
N
IT
Y
As indicated
/1
/2
:1 :0
P
M C
U se rs n al as se k\ D o cu m en ts A u to d es k\ R ev it
P ro je ct s\
M A
B H
-M ec h an ic al n al as se k.
rv t
MH100D-B2
H V
A C
P
LA
N L
O W
E R
L E
V E
L
A R
E A
D
P H
A S
E B
F Y
H
O S
P
IT
A L M
O D
E R
N
IZ
A T
IO
N
M
IS
A W
A A
IR
B
A S
E
J A
P A
N
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
Designer Author Checker
8600 Indian Hills Drive
Omaha, NE 68114-4039
Tel 402.391.8111 Fax
402.391.8564
L A
D P ro je c t N o -1
-0
SCALE: 1 : 100
HVAC PLAN - PHASE B2 LOWER LEVEL AREA D
ENTIRE AHU-6 SUPPLY AND RETURN AIR SYSTEM TO BE
MODIFIED TO MEET UFC STANDARDS. THIS WORK
INCLUDES REPLACING ALL VAV BOXES WITH HOT WATER
REHEAT VAV BOXES, PROVIDING VAV BOXES WHERE
DIFFUSERS CURRENTLY DO NOT HAVE AN UPSTREAM VAV
BOX, AND REMOVING INLINE SUPPLY FANS WITH FINAL
FILTERS.
CONNECT 200X150 EA DUCT TO CANOPY. BALANCE
AIRFLOW TO 76 L/S AT EACH DUCT CONNECTION (153 L/S
TOTAL). SEE DETAIL A1 ON SHEET MH501.
CONNECT 150X150 EA DUCT TO CANOPY. BALANCE
AIRFLOW TO 94 L/S AT EACH DUCT CONNECTION (188 L/S
TOTAL). SEE DETAIL A1 ON SHEET MH501.
DUCT CONNECTION TO CART WASHER. INSTALL PER
MANUFACTURER RECOMMENDATIONS. EXHAUST AIR SHALL
BE BALANCED TO 552 L/S. DUCTWORK SHALL BE STAINLESS
STEEL, CORROSION PROOF, WATER TIGHT, AND SLOPED
BACK TOWARDS CART WASHER.
SUPPLY AIR TO SERVE SERVICE AREA OF CART WASHER
AND MAKEUP AIR FOR EXHAUST/ SERVICE AREA TO BE
OPEN TO AREA ABOVE CART WASHER. COORDINATE WITH
CART WASHER INSTALLATION.
INSTALL DUCT STATIC PRESSURE SENSOR IN EXISTING
SUPPLY MAIN.
PROVIDE STAINLESS STEEL EXHAUST DUCT TO LOCATION
SHOWN AND SLOPE BACK TO CART WASHER.
PROVIDE SATINLESS STEEL EXHAUST DUCTWORK TO
LOCATION SHOWN.
PROVIDE VOLUME DAMPER IN EXISITING BRANCH
DUCTWORK.