Devil's Gate Cistern Bid Sheet_Oct 2018.pdf
PDF 119 KB Posted
- Solicitation number
- RFP GCAA 2019000094 4
- Issued by
- Clear Creek County, Denver City, Colorado
About this file
This is a bid sheet for the Devil's Gate Station Cistern project issued by History Colorado, located at 1200 Broadway, Denver, Colorado. The project encompasses comprehensive site preparation, pipeline installation, cistern construction, electrical work, and site restoration at 1490 W. 121st Ave., Suite 100, Denver, Colorado. Key line items include earthwork operations (site preparation, cut removal, fill, and grading), a 2,000-gallon cistern tank measuring 90 inches in diameter by 83 inches in height with associated components, a Gorman-Rupp T3 3-inch self-priming centrifugal pump system, 4-inch C900 PVC pipe installation with freight, concrete headwall construction at the Clear Creek outfall, electrical installations including 72-inch electric baseboard heaters, fencing work to match existing specifications, and sediment and erosion control measures. The bid sheet specifies quantities in various units including lump sum (LS), each (EA), cubic yards (CY), linear feet (LF), and square yards (SY), with item quantities ranging from single units to 77 cubic yards for earthwork cut removal.
The bid sheet requires contractors to acknowledge receipt of all addenda and provide authorization to submit bids on behalf of their respective companies. Pricing information is organized by line item with columns for unit cost and total cost, though specific dollar amounts are not populated in this document. The project is identified as Bid Sheet 2015-026P14 and includes coordination with engineering firms Galambos Architects, S.K. Peightal Engineers, and RJ McNutt and Associates for architectural, structural, and electrical design requirements. Bidders must address site-specific conditions including river access at headwall elevation, rock retaining wall modifications, and drainage infrastructure integration with existing systems.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 17.193 Georgetown Loop Visitor's Center Addition Report 12.08.17 (reduced file size).pdf | ||
| Electrical Stamped Drawings GLRR Cistern_Part2.pdf | ||
| SC6.21 CONTRACTORS AGREEMENT- DBB A .docx | DOCX document | |
| 2015-026P14 Devil's Gate Station Cistern Intro for bid docs 10.31.2018.pdf | ||
| SC6.23DBB GENERAL CONDITONS.docx | DOCX document | |
| Electrical Stamped Drawings GLRR Cistern_Part1.pdf | ||
| Structural_18001 Devils Gate Cistern 2018-08-10r.pdf | ||
| SC622PerfBond.docx | DOCX document | |
| Civil_Georgetown Loop 8-13-18 a_Part1.pdf | ||
| NOTICE.docx | DOCX document | |
| Architectural_2018 0711 Devil's Gate Cistern_Part1.pdf | ||
| sbp-612_0 Information for Bidders.doc | DOC document | |
| SC6221LMBond.docx | DOCX document | |
| Devil's Gate Station Cistern Q and A.pdf | ||
| sbp-614 Bid Bond.docx | DOCX document | |
| sbp-613 BID.docx | DOCX document | |
| Civil_Georgetown Loop 8-13-18 a_Part2.pdf | ||
| Architectural_2018 0711 Devil's Gate Cistern_Part2.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Owner:
History Colorado
1200 Broadway
Denver, CO 80203
Phone: (303) 447-8679
Item
No.
Units Quantity Unit Cost Total Cost
1.1 LS 1
1.2 EA 3
1.3 LS 1
1.4 LS 1
2.1 CY 77
2.2 CY 54
2.3 LS 1
2.4 LS 1
2.5 CY 5
3.1
LS 1
3.2 EA 2
4.1
EA 2
4.2
LS 1
4.3 LS 1
5.1 CY 3
5.2 CY 5
6.1
LS 1
6.2 EA 4
6.3 LS 1
7.1 LS 1
7.2 LF 11
7.3 EA 1
7.4 LS 1
7.5 SY 13
7.6 CY 5
* I am authorized to submit this bid on behalf of ____________________________, and acknowledge receipt of _______ through ________ addenda.
Signed ____________________________________________________ Date ________________
Mulch around disturbed area
Cistern and Components
2000 gallon Tank (90'' D x 83'' H) including 2'' FNPT Bulthead for additional outlet on bottom of each tank, freight and installation.
Construction Total
Electrical, see electric specific drawings by RJ McNutt and Associates
Fence (to match existing over bridge) along river at headwall elevation, 4ft tall
Site Restoration
Site Restoration and De-mobilization
Final Grading and Drainage Swale Crusher Fines
Fence Swing Gate - 4 foot tall, 4 foot wide
Furnish and Install Heaters - 72'' Electric Baseboard Heater
Coir mat under crusher fines in drainage swale
Furnish and Installation of Rat Guard on both lines
Structure, see Architectural and Structural specific drawings by Galambos Architects and S K
Peightal Engineers
Gorman-Rupp T3, 3''x3'' Self-Priming Centrifugal Pump and System components see scope of supply within specs. Includes installation.
Tank Floodproofing: Ratchet Straps and Concrete Bolts
Furnish and Place Concrete
Headwall at pipe outfall to Clear Creek (colored)
Cistern Building
Stamped concrete above headwall extended to bridge
Bid Sheet
2015-026P14 Devil's Gate Station Cistern1490 W. 121st Ave.
Suite 100
Denver, CO 80234
Phone: (303) 452-6611
Fax: (303) 452-2759
Engineer:
Description
Pipeline and Related
4'' C900 PVC Pipe and system components. See scope of supply within specs. Includes installation. Includes Freight.
Site Preparation
Earthwork Cut
Removal of a portion of rock retaining wall and rock steps
Tree Removal
Earthwork
Mobilization
Earthwork Fill
Removal and replacement of flagstone at discharge into Clear Creek
Trench Squeegee
Permitting
Sediment and Erosion Control: Silt Fence and Straw Sediment Control Logs
File details come from the government source that posted it. Updated .