Architectural_2018 0711 Devil's Gate Cistern_Part1.pdf

PDF 2 MB Posted

Attached to
Devil's Gate Station Cistern-Georgetown Loop Railroad
Solicitation number
RFP GCAA 2019000094 4
Issued by
Clear Creek County, Denver City, Colorado

About this file

Devil's Gate Cistern Project - Architectural Documentation

This file consists of architectural contract documents prepared by Galambos Architects, Inc. for the Devil's Gate Cistern project located at 646 Loop Drive, Georgetown, Colorado 80444. The project involves the construction of a new storage building (S-1 occupancy, Type V-B construction) with associated site work including removal of an existing shed, installation of a new gravel drive, and site preparation. The architectural documentation package includes general information, outline specifications, site plans, floor plans, exterior elevations, building sections, door schedules, and exterior construction details. The project is designed to comply with the 2015 International Building Code (IBC), International Plumbing Code (IPC), International Mechanical Code (IMC), International Energy Conservation Code (IECC), and International Fuel Gas Code (IFGC) for Climate Zone 7. The design was completed in phases, progressing from Schematic Design on December 8, 2017 (revised December 20, 2017) through a Permit Set dated January 26, 2018, to final 100% Construction Documents dated February 9, 2018.

The project specifications establish that all work shall comply with state and local codes and be performed to the highest standards of craftsmanship by journeymen of appropriate trades. The contractor is responsible for all permits, verifying dimensions and site conditions prior to work commencement, and coordinating with the architect regarding any discrepancies in contract documents or field conditions. The building features electric baseboard heating with thermal envelope requirements including R-49 attic insulation, R-13+R-7.5 continuous insulation in wood frame walls, R-10 continuous insulation for below-grade walls, and R-15 insulation for unheated slabs. The project team includes Galambos Architects, Inc. as the architect, SKPE (Steve Peightal) as the structural engineer, EPP & Associates as the surveyor, Cesare, Inc. as the geotechnical engineer, and Applegate Group, Inc. as the civil/mechanical engineer. All shop drawings and material samples require architect review and approval prior to construction commencement.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. THE CONTRACT DOCUMENTS CONSIST OF THE AGREEMENT, THE GENERAL NOTES, THE SPECIFICATIONS AND THE DRAWINGS, WHICH ARE COOPERATIVE AND CONTINUOUS. WORK INDICATED OR REASONABLY IMPLIED IN ANY ONE OF THE DOCUMENTS SHALL BE SUPPLIED AS THOUGH FULLY COVERED IN ALL. ANY DISCREPANCY BETWEEN THE DIFFERENT PARTS SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY FOR CLARIFICATION.

2. THESE DOCUMENTS ARE INTENDED TO INCLUDE ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED TO COMPLETE ALL WORK DESCRIBED HEREIN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT ANY CONDITIONS WHICH WILL NOT PERMIT

CONSTRUCTION.

3. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ORDINANCES AND SHALL BE PERFORMED TO THE HIGHEST STANDARDS OF

CRAFTSMANSHIP BY JOURNEYMEN OF THE APPROPRIATE TRADES.

4. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO STARTING WORK. SHOULD A DISCREPANCY OCCUR BETWEEN THE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS, NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION.

5. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE ON DRAWINGS. SHOULD A DISCREPANCY OCCUR WITHIN THE

CONSTRUCTION DOCUMENTS, CONTRACTOR IS TO CONTACT ARCHITECT FOR DIRECTION.

6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL NEW CONSTRUCTION AT THE SITE. CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS THRU FLOORS, CEILINGS AND WALLS WITH ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL PLUMBING AND

ELECTRICAL DRAWINGS.

7. ALL CONSTRUCTION AND MATERIALS SHALL BE AS SPECIFIED AND IN ACCORDANCE WITH ALL APPLICABLE CODE. ANY MATERIALS PROPOSED FOR

SUBSTITUTION SHALL BE PRESENTED TO THE ARCHITECT FOR APPROVAL.

8. THE JOB SITE SHALL BE MAINTAINED IN A CLEAN AND ORDERLY CONDITION. EACH SUBCONTRACTOR IMMEDIATELY UPON COMPLETION OF EACH

PHASE OF WORK SHALL REMOVE ALL DEBRIS AS A RESULT OF THEIR WORK.

9. THE CONTRACTOR SHALL DO ALL CUTTING, FITTING, PATCHING, EXCAVATION, ETC. OF HIS WORK THAT MAY BE REQUIRED TO PERFORM THEIR WORK.

THIS CUTTING, FITTING, PATCHING, EXCAVATION SHALL NOT ENDANGER OTHER WORK OR STRUCTURES. ALL PATCHING OR REPAIRING SHALL BE DONE WITH LIKE MATERIALS SO THAT SURFACES REPLACED WILL MATCH SURROUNDING SURFACES UPON COMPLETION.

10. NO PORTION OF WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL COMMENCE UNTIL THE SHOP DRAWING OR SAMPLE HAS BEEN

REVIEWED BY THE ARCHITECT, OWNER AND/OR STRUCTURAL ENGINEER, AND APPROVED.

11. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING, BACKING AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL UNITS, EQUIPMENT, AND

ALL OTHER ITEMS AS REQUIRED.

12. PROVIDE ALL ACCESS PANELS AS REQUIRED BY GOVERNING CODES TO ALL CONCEALED SPACES, VOIDS, ATTICS, ETC. VERIFY LOCATION WITH

ARCHITECT PRIOR TO INSTALLATION.

13. CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS RELATED TO THIS WORK. THE BUILDING INSPECTOR SHALL BE NOTIFIED BY THE CONTRACTOR

WHEN THERE IS NEED OF INSPECTION AS REQUIRED BY ANY CODE OR ORDINANCE.

14. IF REQUIRED, FIRE SPRINKLER SYSTEM TO BE DESIGN/BUILD. CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS. CONTRACTOR TO COORDINATE WITH LOCAL FIRE AUTHORITIES FOR ALL APPLICABLE CODES AND REQUIREMENTS. FIRE SPRINKLER SUB CONTRACTOR TO SUBMIT SHOP DRAWINGS TO

THE ARCHITECT FOR REVIEW FOR THIS PORTION OF THE WORK.

15. CONTRACTOR TO PROVIDE ALL SMOKE ALARMS AND CARBON MONOXIDE DETECTORS AS REQUIRED BY APPLICABLE CODES AND ORDINANCES.

COORDINATE LOCATION WITH ARCHITECT.

A3.1X#

D

EXTERIOR ELEVATION

GRID BUBBLE

EL.

T.O. FINISH

100'-0"

A-3XX

X# DETAIL

XX

XX

BUILDING SECTION

A4.1 X#

ELEVATION DATUM

MATCH LINE

NORTH

NORTH ARROW

W1 TYPICAL ASSEMBLY

W1 KEYNOTES

A3.1

X#

X#

INTERIOR ELEVATIONSX# X#

DOOR TAG

WINDOW TAG

REVISION

CONTINUOUS WOOD

WOOD BLOCKING

FINISHED WOOD

CONCRETE

CMU

BATT. INSULATION

RIGID INSULATION

EARTH/GRADE

GRAVEL FILL/BASE

STONE

STEEL

GWB

PLYWOOD

ARCHITECT

GALAMBOS ARCHITECTS, INC.

314 D AABC

ASPEN, CO 81611

TELE: 970.429.1286

FAX: 970.429.1296

CONTACT: JANET LEVERSON

JLEVERSON@GALAMBOSARCHITECTS.NET

GENERAL CONTRACTOR STRUCTURAL ENGINEER

SKPE

298 PARK AVE #301

BASALT CO 81621

TELE: 970.927.9510

CONTACT: STEVE PEIGHTAL

SPEIGHTAL@SOPRIS.NET

SURVEYOR

EPP & ASSOCIATES PROFESSIONAL

LAND SURVEYORS

433 4TH AVENUE WEST

P.O. BOX 1444

CRAIG, CO 81625

TELE: 970.824.8236

CIVIL ENGINEER GEOTECHNICAL ENGINEER

CESARE, INC.

GEOTECHNICAL ENGINEERS &

CONSTRUCTION MATERIALS

CONSULTANTS

7108 SOUTH ALTON WAY, BUILDING B

CENTENNIAL, CO 80112

TELE: 303.220.0300

FAX: 303.220.0442

ENGINEER

APPLEGATE GROUP, INC.

1490 WEST 121ST AVE.,

SUITE 100

DENVER, CO 80234

TELE: 303.452.6611

FAX: 303.452.2759

CONTACT: STEVE SMITH

STEVESMITH@APPLEGATEGROUP.COM

A/C - AIR CONDITIONING

ACT - ACOUSTIC TILE

ADA - AMERICAN W/ DISABILITIES ACT

ADJ - ADJUSTABLE

A.F.F. - ABOVE FINISH FLOOR

ALT. - ALTERNATIVE

APROX. - APPROXIMATE

ARCH - ARCHITECTURAL

BD - BOARD

BITUM - BITUMINOUS

BLDG - BUILDING

BLKG - BLOCKING

BLM - BUREAU OF LAND

MANAGEMENT

BM - BENCHMARK

BO - BOTTOM OF

C&G - CURB AND GUTTER

CABT - CABINET

CIP - CAST IN PLACE

CLG - CEILING

CLO - CLOSET

CLR - CLEAR

CL - CENTERLINE

CMU - CONCRETE MASONRY UNIT

CO - CARBON MONOXIDE DETECTOR

COM - COMMUNICATIONS

CONC - CONCRETE

CONST - CONSTRUCTION

CONT - CONTINUOUS

CPT - CARPET

CSMT - CASEMENT

CTR - CENTER

CT - CERAMIC TILE

DEG - DEGREES

DEMO - DEMOLISH

DTL - DETAIL

DIA - DIAMETER

DIM - DIMENSION

DW - DISHWASHER

DIV - DIVISION

DN - DOWN

DWR - DRAWER

DWG - DRAWING

EDC - EDGE OF CONCRETE

EDP - EDGE OF PAVEMENT

ELEC - ELECTRICAL

ELEV. - ELEVATION

ENGIN - ENGINEER

EA - ENVIRONMENTAL ASSESSMENT

EQ - EQUAL

EQUIP - EQUIPMENT

EST - ESTIMATE

EXIST - EXISTING

EG - EXISTING GRADE

EXT - EXTERIOR

FO - FACE OF

FIN - FINISH

FG - FINISH GRADE

FH - FIRE HYDRANT

FP - FIREPLACE

FIXT - FIXTURE

FLSG - FLASHING

FD - FLOOR DRAIN

FL - FLOWLINE

FT - FOOT OR FEET

FTG - FOOTING

FDN - FOUNDATION

GALV - GALVANIZED

G - GAS

GS - GAS SERVICE

GA - GAUGE

GEN - GENERAL

G.C. - GENERAL CONTRACTOR

GWB - GYPSUM WALLBOARD

HC - HANDICAPPED / ACCESSIBLE

HDWD - HARDWOOD

HVAC - HEATING, VENTILATION

AND AIR CONDITIONING

HT - HEIGHT

HP - HIGHPOINT

HWY - HIGHWAY

HORIZ - HORIZONTAL

HB - HOSE BIBB

HYD - HYDRANT

INSUL - INSULATION

INT - INTERSECTION

JST - JOIST

JB - JUNCTION BOX

KIT - KITCHEN

LAV - LAVATORY

LEED - LEADERSHIP IN ENERGY

AND ENVIR. DESIGN

L - LENGTH

LT - LIGHT POLE

LIN - LINEAR

LF - LINEAR FOOT

LP - LOW POINT

MAINT - MAINTENANCE

MH - MANHOLE

MFR - MANUFACTURER

MATL - MATERIAL

MAX - MAXIMUM

MECH - MECHANICAL

MED - MEDIUM

MEMB - MEMBRANE

M - METERS

M/W - MICROWAVE

MIN - MINIMUM

MISC - MISCELLANEOUS

NATL - NATURAL

NOM - NOMINAL

NIC - NOT IN CONTRACT

NTS - NOT TO SCALE

NO, # - NUMBER

OC - ON CENTER

OP - OUTLET PROTECTION

OPNG - OPENING

OVHD - OVERHEAD

ORIG - ORIGINAL

PERF - PERFORATED

PED - PEDESTRIAN

PL - PLATE

PLY - PLYWOOD

PI - POINT OF INTERSECTION

PT - POINT OF TANGENCY

PREFAB - PREFABRICATED

PM - PROJECT MANAGER

PROP - PROPOSED

QTY - QUANTITY

RAD - RADIUS

RE - REFER TO:

REF - REFRIGERATOR

REINF - REINFORCED

REQ - REQUIRED

R/A - RETURN AIR

REV - REVISION/REVISED

ROW - RIGHT OF WAY

R - RISER

RM - ROOM

RO - ROUGH OPENING

SCHED - SCHEDULE

SECT - SECTION

STBK - SETBACK

SHT - SHEET

SHWR - SHOWER

SW - SIDEWALK

SIM - SIMILAR

SD - SMOKE DETECTOR

SQ - SQUARE

SF - SQUARE FEET

SM - SQUARE METERS

STD - STANDARD

STL - STEEL

STOR - STORAGE

SS - STORM SEWER

STRUCT - STRUCTURAL

S/A - SUPPLY AIR

SYM - SYMMETRICAL

TELE - TELEPHONE

TEMP - TEMPORARY

THK - THICK

T&G - TONGUE AND GROOVE

T.O. - TOP OF

TB - TOWEL BAR

T - TREAD

TYP - TYPICAL

UE - UNDERGROUND ELECTRIC

UNFIN - UNFINISHED

UNO - UNLESS NOTED OTHERWISE

UON - UNLESS OTHERWISE NOTED

UTIL - UTILITY

VB - VAPOR BARRIER

VENT - VENTILATION

VIF - VERIFY IN FIELD

VERT - VERTICAL

VG - VERTICAL GRAIN

WSCT - WAINSCOT

W - WATER

W/C - WATER CLOSET

WP - WATERPROOF

WDW - WINDOW

WD - WOOD

ISSUE FOR

G A

TH

IS

D R A W

IN

G

I S T

H E

PR

O

PE

R

TY

O F

G A

LA

M

BO

S A

R C H

IT

EC

TS

I

N C

A

LL

W R

IT

TE

N

A N

D D

R A W

N I

N

FO

R M

A

TI

O N

A

PP

EA

R

IN

G H

ER

EI

N S

H A

LL

N O

T

BE

D U

PL

IC

A

TE

D

D

IS

C

LO

S

ED

O R O

TH

ER

W

IS

E U

S

ED

W

IT

H O

U T

TH

E

W R

IT

TE

N

C O

N C

EN

T O

F G

AL

A M

B O

S A R C H

IT

EC

TS

I

N C

O

PY

R

IG

H T

G A L A M B O S

ARCHITECTS, INC.

314 D AABC

ASPEN, CO 81611

(970) 429-1286

DATE

DRAWING

DATE

PROJECT

7/

/2

2:

:3

PM

D

EV

IL

'S

G A

TE

C

IS

TE

R N

Lo op

D riv e, G eo rg et ow n, C

O

CVR

GENERAL INFORMATION

02/09/2018

DEVIL'S GATE CISTERN

CVR GENERAL INFORMATION

T-001 OUTLINE SPECIFICATION

T-002 OUTLINE SPECIFICATION

A-001 SITE PLAN

A-101 PLANS

A-201 EXTERIOR ELEVATIONS

A-301 BUILDING SECTIONS/DOOR SCHEDULE

A-501 EXTERIOR CONSTRUCTION DETAILS

ABBREVIATIONS

ARCHITECTURAL SYMBOLS/DRAFTING CONVENTIONS

GENERAL NOTES

PROJECT TEAM

CODE COMPLIANCE

DRAWING INDEX

VICINITY MAP

SITE LOCATION:

646 LOOP DRIVE

APPLICABLE CODES: 2015 IBC, IPC, IMC, IECC, IFGC,

PER 2015 IECC, (PRESCRIPTIVE METHOD):

C402.1.3 CLIMATE ZONE 7 PER TABLE (BUILDING IS HEATED BY MEANS OF ELECTRIC BASEBOARD):

-ATTIC AND OTHER: R-49

-WOOD FRAME WALL R-13+R-7.5CI

-BELOW GRADE WALL: R-10CI

-UNHEATED SLABS: R-15 FOR 24 IN. BELOW

C402.3: BUILDING IS NOT COOLED

C402.4: BUILDING HAS NO GLAZED OPENINGS.

C402.5: THE THERMAL ENVELOPE OF BUILDINGS SHALL COMPLY WITH SECTIONS C402.5.1 THROUGH C402.5.8 OR THE THRERMAL ENVELOPE SHALL BE TESTED IN ACCORDANCE

WITH ASTM E 779.

C405.2.1: OCCUPANT SENSOR CONTROLS SHALL BE INSTALLED TO CONTROL LIGHTS

BUILDING INFORMATION

PROJECT DESCRIPTION

STORAGE

BUILDING CODE ANALYSIS

OCCUPANCY TYPE: S-1

CONSTRUCTION TYPE: V-B

Schematic Design 12.08.17 SD Revised 12.20.17 Permit Set 01.26.2018

100% CD 02.09.2018

ISSUE FOR

G A

TH

IS

D R A W

IN

G

I S T

H E

PR

O

PE

R

TY

O F

G A

LA

M

BO

S A

R C H

IT

EC

TS

I

N C

A

LL

W R

IT

TE

N

A N

D D

R A W

N I

N

FO

R M

A

TI

O N

A

PP

EA

R

IN

G H

ER

EI

N S

H A

LL

N O

T

BE

D U

PL

IC

A

TE

D

D

IS

C

LO

S

ED

O R O

TH

ER

W

IS

E U

S

ED

W

IT

H O

U T

TH

E

W R

IT

TE

N

C O

N C

EN

T O

F G

AL

A M

B O

S A R C H

IT

EC

TS

I

O

PY

R

IG

H T

G A L A M B O S

ARCHITECTS, INC.

314 D AABC

ASPEN, CO 81611

(970) 429-1286

DATE

DRAWING

DATE

PROJECT

7/

/2

2:

:4

PM

D

EV

IL

'S

G A

TE

C

IS

TE

R N

Lo op

D riv e, G eo rg et ow n, C

O

T-001

OUTLINE SPECIFICATION

02/09/2018

DEVIL'S GATE CISTERN

ISSUE FOR

G A

TH

IS

D R A W

IN

G

I S T

H E

PR

O

PE

R

TY

O F

G A

LA

M

BO

S A

R C H

IT

EC

TS

I

N C

A

LL

W R

IT

TE

N

A N

D D

R A W

N I

N

FO

R M

A

TI

O N

A

PP

EA

R

IN

G H

ER

EI

N S

H A

LL

N O

T

BE

D U

PL

IC

A

TE

D

D

IS

C

LO

S

ED

O R O

TH

ER

W

IS

E U

S

ED

W

IT

H O

U T

TH

E

W R

IT

TE

N

C O

N C

EN

T O

F G

AL

A M

B O

S A R C H

IT

EC

TS

I

O

PY

R

IG

H T

G A L A M B O S

ARCHITECTS, INC.

314 D AABC

ASPEN, CO 81611

(970) 429-1286

DATE

DRAWING

DATE

PROJECT

7/

/2

2:

:4

PM

D

EV

IL

'S

G A

TE

C

IS

TE

R N

Lo op

D riv e, G eo rg et ow n, C

O

T-002

OUTLINE SPECIFICATION

02/09/2018

DEVIL'S GATE CISTERN

REMOVE EXIST SHED

NEW CISTERN

STORAGE

NEW GRAVEL DRIVE

TIE TO EXIST DRIVE

EXISTING BUILDING

T.O. SLAB

MATCH EXIST BLDG SLAB

ISSUE FOR

G A

TH

IS

D R A W

IN

G

I S T

H E

PR

O

PE

R

TY

O F

G A

LA

M

BO

S A

R C H

IT

EC

TS

I

N C

A

LL

W R

IT

TE

N

A N

D D

R A W

N I

N

FO

R M

A

TI

O N

A

PP

EA

R

IN

G H

ER

EI

N S

H A

LL

N O

T

BE

D U

PL

IC

A

TE

D

D

IS

C

LO

S

ED

O R O

TH

ER

W

IS

E U

S

ED

W

IT

H O

U T

TH

E

W R

IT

TE

N

C O

N C

EN

T O

F G

AL

A M

B O

S A R C H

IT

EC

TS

I

O

PY

R

IG

H T

G A L A M B O S

ARCHITECTS, INC.

314 D AABC

ASPEN, CO 81611

(970) 429-1286

DATE

DRAWING

DATE

PROJECT

7/

/2

2:

:1

PM

D

EV

IL

'S

G A

TE

C

IS

TE

R N

Lo op

D riv e, G eo rg et ow n, C

O

A-001

SITE PLAN

02/09/2018

DEVIL'S GATE CISTERN

NORTH

SCALE 1" = 10'-0"1 SITE PLAN

Schematic Design 12.08.17 SD Revised 12.20.17

Sheets
A-001 - SITE PLAN
A-101 - PLANS
A-201 - EXTERIOR ELEVATIONS
A-301 - BUILDING SECTIONS/DOOR SCHEDULE
A-501 - EXTERIOR CONSTRUCTION DETAILS
CVR - GENERAL INFORMATION
T-001 - OUTLINE SPECIFICATION
T-002 - OUTLINE SPECIFICATION
Devil's Gate_Central_jleverson@galambosarchitects.net - Sheet - T-002 - OUTLINE SPECIFICATION.pdf
Sheets
A-001 - SITE PLAN
A-101 - PLANS
A-201 - EXTERIOR ELEVATIONS
A-301 - BUILDING SECTIONS/DOOR SCHEDULE
A-501 - EXTERIOR CONSTRUCTION DETAILS
CVR - GENERAL INFORMATION
T-001 - OUTLINE SPECIFICATION
T-002 - OUTLINE SPECIFICATION
Devil's Gate_Central_jleverson@galambosarchitects.net - Sheet - T-001 - OUTLINE SPECIFICATION.pdf
Sheets
A-001 - SITE PLAN
A-101 - PLANS
A-201 - EXTERIOR ELEVATIONS
A-301 - BUILDING SECTIONS/DOOR SCHEDULE
A-501 - EXTERIOR CONSTRUCTION DETAILS
CVR - GENERAL INFORMATION
T-001 - OUTLINE SPECIFICATION
T-002 - OUTLINE SPECIFICATION
Devil's Gate_Central_jleverson@galambosarchitects.net - Sheet - A-001 - SITE PLAN.pdf
Sheets
A-001 - SITE PLAN
A-101 - PLANS
A-201 - EXTERIOR ELEVATIONS
A-301 - BUILDING SECTIONS/DOOR SCHEDULE
A-501 - EXTERIOR CONSTRUCTION DETAILS
CVR - GENERAL INFORMATION
T-001 - OUTLINE SPECIFICATION
T-002 - OUTLINE SPECIFICATION
Devil's Gate_Central_jleverson@galambosarchitects.net - Sheet - A-101 - PLANS.pdf
Sheets
A-001 - SITE PLAN
A-101 - PLANS
A-201 - EXTERIOR ELEVATIONS
A-301 - BUILDING SECTIONS/DOOR SCHEDULE
A-501 - EXTERIOR CONSTRUCTION DETAILS
CVR - GENERAL INFORMATION
T-001 - OUTLINE SPECIFICATION
T-002 - OUTLINE SPECIFICATION
Devil's Gate_Central_jleverson@galambosarchitects.net - Sheet - A-201 - EXTERIOR ELEVATIONS.pdf
Sheets
A-001 - SITE PLAN
A-101 - PLANS
A-201 - EXTERIOR ELEVATIONS
A-301 - BUILDING SECTIONS/DOOR SCHEDULE
A-501 - EXTERIOR CONSTRUCTION DETAILS
CVR - GENERAL INFORMATION
T-001 - OUTLINE SPECIFICATION
T-002 - OUTLINE SPECIFICATION
Devil's Gate_Central_jleverson@galambosarchitects.net - Sheet - A-301 - BUILDING SECTIONS-DOOR SCHEDULE.pdf
Sheets
A-001 - SITE PLAN
A-101 - PLANS
A-201 - EXTERIOR ELEVATIONS
A-301 - BUILDING SECTIONS/DOOR SCHEDULE
A-501 - EXTERIOR CONSTRUCTION DETAILS
CVR - GENERAL INFORMATION
T-001 - OUTLINE SPECIFICATION
T-002 - OUTLINE SPECIFICATION
Devil's Gate_Central_jleverson@galambosarchitects.net - Sheet - A-501 - EXTERIOR CONSTRUCTION DETAILS.pdf
Sheets
A-001 - SITE PLAN
A-101 - PLANS
A-201 - EXTERIOR ELEVATIONS
A-301 - BUILDING SECTIONS/DOOR SCHEDULE
A-501 - EXTERIOR CONSTRUCTION DETAILS
CVR - GENERAL INFORMATION
T-001 - OUTLINE SPECIFICATION
T-002 - OUTLINE SPECIFICATION

File details come from the government source that posted it. Updated .