About this file
Devil's Gate Cistern Project - Architectural Documentation
This file consists of architectural contract documents prepared by Galambos Architects, Inc. for the Devil's Gate Cistern project located at 646 Loop Drive, Georgetown, Colorado 80444. The project involves the construction of a new storage building (S-1 occupancy, Type V-B construction) with associated site work including removal of an existing shed, installation of a new gravel drive, and site preparation. The architectural documentation package includes general information, outline specifications, site plans, floor plans, exterior elevations, building sections, door schedules, and exterior construction details. The project is designed to comply with the 2015 International Building Code (IBC), International Plumbing Code (IPC), International Mechanical Code (IMC), International Energy Conservation Code (IECC), and International Fuel Gas Code (IFGC) for Climate Zone 7. The design was completed in phases, progressing from Schematic Design on December 8, 2017 (revised December 20, 2017) through a Permit Set dated January 26, 2018, to final 100% Construction Documents dated February 9, 2018.
The project specifications establish that all work shall comply with state and local codes and be performed to the highest standards of craftsmanship by journeymen of appropriate trades. The contractor is responsible for all permits, verifying dimensions and site conditions prior to work commencement, and coordinating with the architect regarding any discrepancies in contract documents or field conditions. The building features electric baseboard heating with thermal envelope requirements including R-49 attic insulation, R-13+R-7.5 continuous insulation in wood frame walls, R-10 continuous insulation for below-grade walls, and R-15 insulation for unheated slabs. The project team includes Galambos Architects, Inc. as the architect, SKPE (Steve Peightal) as the structural engineer, EPP & Associates as the surveyor, Cesare, Inc. as the geotechnical engineer, and Applegate Group, Inc. as the civil/mechanical engineer. All shop drawings and material samples require architect review and approval prior to construction commencement.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 17.193 Georgetown Loop Visitor's Center Addition Report 12.08.17 (reduced file size).pdf | ||
| Electrical Stamped Drawings GLRR Cistern_Part2.pdf | ||
| SC6.21 CONTRACTORS AGREEMENT- DBB A .docx | DOCX document | |
| 2015-026P14 Devil's Gate Station Cistern Intro for bid docs 10.31.2018.pdf | ||
| SC6.23DBB GENERAL CONDITONS.docx | DOCX document | |
| Electrical Stamped Drawings GLRR Cistern_Part1.pdf | ||
| Structural_18001 Devils Gate Cistern 2018-08-10r.pdf | ||
| SC622PerfBond.docx | DOCX document | |
| Civil_Georgetown Loop 8-13-18 a_Part1.pdf | ||
| NOTICE.docx | DOCX document | |
| Devil's Gate Cistern Bid Sheet_Oct 2018.pdf | ||
| sbp-612_0 Information for Bidders.doc | DOC document | |
| SC6221LMBond.docx | DOCX document | |
| Devil's Gate Station Cistern Q and A.pdf | ||
| sbp-614 Bid Bond.docx | DOCX document | |
| sbp-613 BID.docx | DOCX document | |
| Civil_Georgetown Loop 8-13-18 a_Part2.pdf | ||
| Architectural_2018 0711 Devil's Gate Cistern_Part2.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. THE CONTRACT DOCUMENTS CONSIST OF THE AGREEMENT, THE GENERAL NOTES, THE SPECIFICATIONS AND THE DRAWINGS, WHICH ARE COOPERATIVE AND CONTINUOUS. WORK INDICATED OR REASONABLY IMPLIED IN ANY ONE OF THE DOCUMENTS SHALL BE SUPPLIED AS THOUGH FULLY COVERED IN ALL. ANY DISCREPANCY BETWEEN THE DIFFERENT PARTS SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY FOR CLARIFICATION.
2. THESE DOCUMENTS ARE INTENDED TO INCLUDE ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED TO COMPLETE ALL WORK DESCRIBED HEREIN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT ANY CONDITIONS WHICH WILL NOT PERMIT
CONSTRUCTION.
3. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ORDINANCES AND SHALL BE PERFORMED TO THE HIGHEST STANDARDS OF
CRAFTSMANSHIP BY JOURNEYMEN OF THE APPROPRIATE TRADES.
4. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO STARTING WORK. SHOULD A DISCREPANCY OCCUR BETWEEN THE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS, NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION.
5. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE ON DRAWINGS. SHOULD A DISCREPANCY OCCUR WITHIN THE
CONSTRUCTION DOCUMENTS, CONTRACTOR IS TO CONTACT ARCHITECT FOR DIRECTION.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL NEW CONSTRUCTION AT THE SITE. CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS THRU FLOORS, CEILINGS AND WALLS WITH ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL PLUMBING AND
ELECTRICAL DRAWINGS.
7. ALL CONSTRUCTION AND MATERIALS SHALL BE AS SPECIFIED AND IN ACCORDANCE WITH ALL APPLICABLE CODE. ANY MATERIALS PROPOSED FOR
SUBSTITUTION SHALL BE PRESENTED TO THE ARCHITECT FOR APPROVAL.
8. THE JOB SITE SHALL BE MAINTAINED IN A CLEAN AND ORDERLY CONDITION. EACH SUBCONTRACTOR IMMEDIATELY UPON COMPLETION OF EACH
PHASE OF WORK SHALL REMOVE ALL DEBRIS AS A RESULT OF THEIR WORK.
9. THE CONTRACTOR SHALL DO ALL CUTTING, FITTING, PATCHING, EXCAVATION, ETC. OF HIS WORK THAT MAY BE REQUIRED TO PERFORM THEIR WORK.
THIS CUTTING, FITTING, PATCHING, EXCAVATION SHALL NOT ENDANGER OTHER WORK OR STRUCTURES. ALL PATCHING OR REPAIRING SHALL BE DONE WITH LIKE MATERIALS SO THAT SURFACES REPLACED WILL MATCH SURROUNDING SURFACES UPON COMPLETION.
10. NO PORTION OF WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL COMMENCE UNTIL THE SHOP DRAWING OR SAMPLE HAS BEEN
REVIEWED BY THE ARCHITECT, OWNER AND/OR STRUCTURAL ENGINEER, AND APPROVED.
11. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING, BACKING AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL UNITS, EQUIPMENT, AND
ALL OTHER ITEMS AS REQUIRED.
12. PROVIDE ALL ACCESS PANELS AS REQUIRED BY GOVERNING CODES TO ALL CONCEALED SPACES, VOIDS, ATTICS, ETC. VERIFY LOCATION WITH
ARCHITECT PRIOR TO INSTALLATION.
13. CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS RELATED TO THIS WORK. THE BUILDING INSPECTOR SHALL BE NOTIFIED BY THE CONTRACTOR
WHEN THERE IS NEED OF INSPECTION AS REQUIRED BY ANY CODE OR ORDINANCE.
14. IF REQUIRED, FIRE SPRINKLER SYSTEM TO BE DESIGN/BUILD. CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS. CONTRACTOR TO COORDINATE WITH LOCAL FIRE AUTHORITIES FOR ALL APPLICABLE CODES AND REQUIREMENTS. FIRE SPRINKLER SUB CONTRACTOR TO SUBMIT SHOP DRAWINGS TO
THE ARCHITECT FOR REVIEW FOR THIS PORTION OF THE WORK.
15. CONTRACTOR TO PROVIDE ALL SMOKE ALARMS AND CARBON MONOXIDE DETECTORS AS REQUIRED BY APPLICABLE CODES AND ORDINANCES.
COORDINATE LOCATION WITH ARCHITECT.
A3.1X#
D
EXTERIOR ELEVATION
GRID BUBBLE
EL.
T.O. FINISH
100'-0"
A-3XX
X# DETAIL
XX
XX
BUILDING SECTION
A4.1 X#
ELEVATION DATUM
MATCH LINE
NORTH
NORTH ARROW
W1 TYPICAL ASSEMBLY
W1 KEYNOTES
A3.1
X#
X#
INTERIOR ELEVATIONSX# X#
DOOR TAG
WINDOW TAG
REVISION
CONTINUOUS WOOD
WOOD BLOCKING
FINISHED WOOD
CONCRETE
CMU
BATT. INSULATION
RIGID INSULATION
EARTH/GRADE
GRAVEL FILL/BASE
STONE
STEEL
GWB
PLYWOOD
ARCHITECT
GALAMBOS ARCHITECTS, INC.
314 D AABC
ASPEN, CO 81611
TELE: 970.429.1286
FAX: 970.429.1296
CONTACT: JANET LEVERSON
JLEVERSON@GALAMBOSARCHITECTS.NET
GENERAL CONTRACTOR STRUCTURAL ENGINEER
SKPE
298 PARK AVE #301
BASALT CO 81621
TELE: 970.927.9510
CONTACT: STEVE PEIGHTAL
SPEIGHTAL@SOPRIS.NET
SURVEYOR
EPP & ASSOCIATES PROFESSIONAL
LAND SURVEYORS
433 4TH AVENUE WEST
P.O. BOX 1444
CRAIG, CO 81625
TELE: 970.824.8236
CIVIL ENGINEER GEOTECHNICAL ENGINEER
CESARE, INC.
GEOTECHNICAL ENGINEERS &
CONSTRUCTION MATERIALS
CONSULTANTS
7108 SOUTH ALTON WAY, BUILDING B
CENTENNIAL, CO 80112
TELE: 303.220.0300
FAX: 303.220.0442
ENGINEER
APPLEGATE GROUP, INC.
1490 WEST 121ST AVE.,
SUITE 100
DENVER, CO 80234
TELE: 303.452.6611
FAX: 303.452.2759
CONTACT: STEVE SMITH
STEVESMITH@APPLEGATEGROUP.COM
A/C - AIR CONDITIONING
ACT - ACOUSTIC TILE
ADA - AMERICAN W/ DISABILITIES ACT
ADJ - ADJUSTABLE
A.F.F. - ABOVE FINISH FLOOR
ALT. - ALTERNATIVE
APROX. - APPROXIMATE
ARCH - ARCHITECTURAL
BD - BOARD
BITUM - BITUMINOUS
BLDG - BUILDING
BLKG - BLOCKING
BLM - BUREAU OF LAND
MANAGEMENT
BM - BENCHMARK
BO - BOTTOM OF
C&G - CURB AND GUTTER
CABT - CABINET
CIP - CAST IN PLACE
CLG - CEILING
CLO - CLOSET
CLR - CLEAR
CL - CENTERLINE
CMU - CONCRETE MASONRY UNIT
CO - CARBON MONOXIDE DETECTOR
COM - COMMUNICATIONS
CONC - CONCRETE
CONST - CONSTRUCTION
CONT - CONTINUOUS
CPT - CARPET
CSMT - CASEMENT
CTR - CENTER
CT - CERAMIC TILE
DEG - DEGREES
DEMO - DEMOLISH
DTL - DETAIL
DIA - DIAMETER
DIM - DIMENSION
DW - DISHWASHER
DIV - DIVISION
DN - DOWN
DWR - DRAWER
DWG - DRAWING
EDC - EDGE OF CONCRETE
EDP - EDGE OF PAVEMENT
ELEC - ELECTRICAL
ELEV. - ELEVATION
ENGIN - ENGINEER
EA - ENVIRONMENTAL ASSESSMENT
EQ - EQUAL
EQUIP - EQUIPMENT
EST - ESTIMATE
EXIST - EXISTING
EG - EXISTING GRADE
EXT - EXTERIOR
FO - FACE OF
FIN - FINISH
FG - FINISH GRADE
FH - FIRE HYDRANT
FP - FIREPLACE
FIXT - FIXTURE
FLSG - FLASHING
FD - FLOOR DRAIN
FL - FLOWLINE
FT - FOOT OR FEET
FTG - FOOTING
FDN - FOUNDATION
GALV - GALVANIZED
G - GAS
GS - GAS SERVICE
GA - GAUGE
GEN - GENERAL
G.C. - GENERAL CONTRACTOR
GWB - GYPSUM WALLBOARD
HC - HANDICAPPED / ACCESSIBLE
HDWD - HARDWOOD
HVAC - HEATING, VENTILATION
AND AIR CONDITIONING
HT - HEIGHT
HP - HIGHPOINT
HWY - HIGHWAY
HORIZ - HORIZONTAL
HB - HOSE BIBB
HYD - HYDRANT
INSUL - INSULATION
INT - INTERSECTION
JST - JOIST
JB - JUNCTION BOX
KIT - KITCHEN
LAV - LAVATORY
LEED - LEADERSHIP IN ENERGY
AND ENVIR. DESIGN
L - LENGTH
LT - LIGHT POLE
LIN - LINEAR
LF - LINEAR FOOT
LP - LOW POINT
MAINT - MAINTENANCE
MH - MANHOLE
MFR - MANUFACTURER
MATL - MATERIAL
MAX - MAXIMUM
MECH - MECHANICAL
MED - MEDIUM
MEMB - MEMBRANE
M - METERS
M/W - MICROWAVE
MIN - MINIMUM
MISC - MISCELLANEOUS
NATL - NATURAL
NOM - NOMINAL
NIC - NOT IN CONTRACT
NTS - NOT TO SCALE
NO, # - NUMBER
OC - ON CENTER
OP - OUTLET PROTECTION
OPNG - OPENING
OVHD - OVERHEAD
ORIG - ORIGINAL
PERF - PERFORATED
PED - PEDESTRIAN
PL - PLATE
PLY - PLYWOOD
PI - POINT OF INTERSECTION
PT - POINT OF TANGENCY
PREFAB - PREFABRICATED
PM - PROJECT MANAGER
PROP - PROPOSED
QTY - QUANTITY
RAD - RADIUS
RE - REFER TO:
REF - REFRIGERATOR
REINF - REINFORCED
REQ - REQUIRED
R/A - RETURN AIR
REV - REVISION/REVISED
ROW - RIGHT OF WAY
R - RISER
RM - ROOM
RO - ROUGH OPENING
SCHED - SCHEDULE
SECT - SECTION
STBK - SETBACK
SHT - SHEET
SHWR - SHOWER
SW - SIDEWALK
SIM - SIMILAR
SD - SMOKE DETECTOR
SQ - SQUARE
SF - SQUARE FEET
SM - SQUARE METERS
STD - STANDARD
STL - STEEL
STOR - STORAGE
SS - STORM SEWER
STRUCT - STRUCTURAL
S/A - SUPPLY AIR
SYM - SYMMETRICAL
TELE - TELEPHONE
TEMP - TEMPORARY
THK - THICK
T&G - TONGUE AND GROOVE
T.O. - TOP OF
TB - TOWEL BAR
T - TREAD
TYP - TYPICAL
UE - UNDERGROUND ELECTRIC
UNFIN - UNFINISHED
UNO - UNLESS NOTED OTHERWISE
UON - UNLESS OTHERWISE NOTED
UTIL - UTILITY
VB - VAPOR BARRIER
VENT - VENTILATION
VIF - VERIFY IN FIELD
VERT - VERTICAL
VG - VERTICAL GRAIN
WSCT - WAINSCOT
W - WATER
W/C - WATER CLOSET
WP - WATERPROOF
WDW - WINDOW
WD - WOOD
ISSUE FOR
G A
TH
IS
D R A W
IN
G
I S T
H E
PR
O
PE
R
TY
O F
G A
LA
M
BO
S A
R C H
IT
EC
TS
I
N C
A
LL
W R
IT
TE
N
A N
D D
R A W
N I
N
FO
R M
A
TI
O N
A
PP
EA
R
IN
G H
ER
EI
N S
H A
LL
N O
T
BE
D U
PL
IC
A
TE
D
D
IS
C
LO
S
ED
O R O
TH
ER
W
IS
E U
S
ED
W
IT
H O
U T
TH
E
W R
IT
TE
N
C O
N C
EN
T O
F G
AL
A M
B O
S A R C H
IT
EC
TS
I
N C
O
PY
R
IG
H T
G A L A M B O S
ARCHITECTS, INC.
314 D AABC
ASPEN, CO 81611
(970) 429-1286
DATE
DRAWING
DATE
PROJECT
7/
/2
2:
:3
PM
D
EV
IL
'S
G A
TE
C
IS
TE
R N
Lo op
D riv e, G eo rg et ow n, C
O
CVR
GENERAL INFORMATION
02/09/2018
DEVIL'S GATE CISTERN
CVR GENERAL INFORMATION
T-001 OUTLINE SPECIFICATION
T-002 OUTLINE SPECIFICATION
A-001 SITE PLAN
A-101 PLANS
A-201 EXTERIOR ELEVATIONS
A-301 BUILDING SECTIONS/DOOR SCHEDULE
A-501 EXTERIOR CONSTRUCTION DETAILS
ABBREVIATIONS
ARCHITECTURAL SYMBOLS/DRAFTING CONVENTIONS
GENERAL NOTES
PROJECT TEAM
CODE COMPLIANCE
DRAWING INDEX
VICINITY MAP
SITE LOCATION:
646 LOOP DRIVE
APPLICABLE CODES: 2015 IBC, IPC, IMC, IECC, IFGC,
PER 2015 IECC, (PRESCRIPTIVE METHOD):
C402.1.3 CLIMATE ZONE 7 PER TABLE (BUILDING IS HEATED BY MEANS OF ELECTRIC BASEBOARD):
-ATTIC AND OTHER: R-49
-WOOD FRAME WALL R-13+R-7.5CI
-BELOW GRADE WALL: R-10CI
-UNHEATED SLABS: R-15 FOR 24 IN. BELOW
C402.3: BUILDING IS NOT COOLED
C402.4: BUILDING HAS NO GLAZED OPENINGS.
C402.5: THE THERMAL ENVELOPE OF BUILDINGS SHALL COMPLY WITH SECTIONS C402.5.1 THROUGH C402.5.8 OR THE THRERMAL ENVELOPE SHALL BE TESTED IN ACCORDANCE
WITH ASTM E 779.
C405.2.1: OCCUPANT SENSOR CONTROLS SHALL BE INSTALLED TO CONTROL LIGHTS
BUILDING INFORMATION
PROJECT DESCRIPTION
STORAGE
BUILDING CODE ANALYSIS
OCCUPANCY TYPE: S-1
CONSTRUCTION TYPE: V-B
Schematic Design 12.08.17 SD Revised 12.20.17 Permit Set 01.26.2018
100% CD 02.09.2018
ISSUE FOR
G A
TH
IS
D R A W
IN
G
I S T
H E
PR
O
PE
R
TY
O F
G A
LA
M
BO
S A
R C H
IT
EC
TS
I
N C
A
LL
W R
IT
TE
N
A N
D D
R A W
N I
N
FO
R M
A
TI
O N
A
PP
EA
R
IN
G H
ER
EI
N S
H A
LL
N O
T
BE
D U
PL
IC
A
TE
D
D
IS
C
LO
S
ED
O R O
TH
ER
W
IS
E U
S
ED
W
IT
H O
U T
TH
E
W R
IT
TE
N
C O
N C
EN
T O
F G
AL
A M
B O
S A R C H
IT
EC
TS
I
O
PY
R
IG
H T
G A L A M B O S
ARCHITECTS, INC.
314 D AABC
ASPEN, CO 81611
(970) 429-1286
DATE
DRAWING
DATE
PROJECT
7/
/2
2:
:4
PM
D
EV
IL
'S
G A
TE
C
IS
TE
R N
Lo op
D riv e, G eo rg et ow n, C
O
T-001
OUTLINE SPECIFICATION
02/09/2018
DEVIL'S GATE CISTERN
ISSUE FOR
G A
TH
IS
D R A W
IN
G
I S T
H E
PR
O
PE
R
TY
O F
G A
LA
M
BO
S A
R C H
IT
EC
TS
I
N C
A
LL
W R
IT
TE
N
A N
D D
R A W
N I
N
FO
R M
A
TI
O N
A
PP
EA
R
IN
G H
ER
EI
N S
H A
LL
N O
T
BE
D U
PL
IC
A
TE
D
D
IS
C
LO
S
ED
O R O
TH
ER
W
IS
E U
S
ED
W
IT
H O
U T
TH
E
W R
IT
TE
N
C O
N C
EN
T O
F G
AL
A M
B O
S A R C H
IT
EC
TS
I
O
PY
R
IG
H T
G A L A M B O S
ARCHITECTS, INC.
314 D AABC
ASPEN, CO 81611
(970) 429-1286
DATE
DRAWING
DATE
PROJECT
7/
/2
2:
:4
PM
D
EV
IL
'S
G A
TE
C
IS
TE
R N
Lo op
D riv e, G eo rg et ow n, C
O
T-002
OUTLINE SPECIFICATION
02/09/2018
DEVIL'S GATE CISTERN
REMOVE EXIST SHED
NEW CISTERN
STORAGE
NEW GRAVEL DRIVE
TIE TO EXIST DRIVE
EXISTING BUILDING
T.O. SLAB
MATCH EXIST BLDG SLAB
ISSUE FOR
G A
TH
IS
D R A W
IN
G
I S T
H E
PR
O
PE
R
TY
O F
G A
LA
M
BO
S A
R C H
IT
EC
TS
I
N C
A
LL
W R
IT
TE
N
A N
D D
R A W
N I
N
FO
R M
A
TI
O N
A
PP
EA
R
IN
G H
ER
EI
N S
H A
LL
N O
T
BE
D U
PL
IC
A
TE
D
D
IS
C
LO
S
ED
O R O
TH
ER
W
IS
E U
S
ED
W
IT
H O
U T
TH
E
W R
IT
TE
N
C O
N C
EN
T O
F G
AL
A M
B O
S A R C H
IT
EC
TS
I
O
PY
R
IG
H T
G A L A M B O S
ARCHITECTS, INC.
314 D AABC
ASPEN, CO 81611
(970) 429-1286
DATE
DRAWING
DATE
PROJECT
7/
/2
2:
:1
PM
D
EV
IL
'S
G A
TE
C
IS
TE
R N
Lo op
D riv e, G eo rg et ow n, C
O
A-001
SITE PLAN
02/09/2018
DEVIL'S GATE CISTERN
NORTH
SCALE 1" = 10'-0"1 SITE PLAN
Schematic Design 12.08.17 SD Revised 12.20.17
| Sheets |
| A-001 - SITE PLAN |
| A-101 - PLANS |
| A-201 - EXTERIOR ELEVATIONS |
| A-301 - BUILDING SECTIONS/DOOR SCHEDULE |
| A-501 - EXTERIOR CONSTRUCTION DETAILS |
| CVR - GENERAL INFORMATION |
| T-001 - OUTLINE SPECIFICATION |
| T-002 - OUTLINE SPECIFICATION |
| Devil's Gate_Central_jleverson@galambosarchitects.net - Sheet - T-002 - OUTLINE SPECIFICATION.pdf |
| Sheets |
| A-001 - SITE PLAN |
| A-101 - PLANS |
| A-201 - EXTERIOR ELEVATIONS |
| A-301 - BUILDING SECTIONS/DOOR SCHEDULE |
| A-501 - EXTERIOR CONSTRUCTION DETAILS |
| CVR - GENERAL INFORMATION |
| T-001 - OUTLINE SPECIFICATION |
| T-002 - OUTLINE SPECIFICATION |
| Devil's Gate_Central_jleverson@galambosarchitects.net - Sheet - T-001 - OUTLINE SPECIFICATION.pdf |
| Sheets |
| A-001 - SITE PLAN |
| A-101 - PLANS |
| A-201 - EXTERIOR ELEVATIONS |
| A-301 - BUILDING SECTIONS/DOOR SCHEDULE |
| A-501 - EXTERIOR CONSTRUCTION DETAILS |
| CVR - GENERAL INFORMATION |
| T-001 - OUTLINE SPECIFICATION |
| T-002 - OUTLINE SPECIFICATION |
| Devil's Gate_Central_jleverson@galambosarchitects.net - Sheet - A-001 - SITE PLAN.pdf |
| Sheets |
| A-001 - SITE PLAN |
| A-101 - PLANS |
| A-201 - EXTERIOR ELEVATIONS |
| A-301 - BUILDING SECTIONS/DOOR SCHEDULE |
| A-501 - EXTERIOR CONSTRUCTION DETAILS |
| CVR - GENERAL INFORMATION |
| T-001 - OUTLINE SPECIFICATION |
| T-002 - OUTLINE SPECIFICATION |
| Devil's Gate_Central_jleverson@galambosarchitects.net - Sheet - A-101 - PLANS.pdf |
| Sheets |
| A-001 - SITE PLAN |
| A-101 - PLANS |
| A-201 - EXTERIOR ELEVATIONS |
| A-301 - BUILDING SECTIONS/DOOR SCHEDULE |
| A-501 - EXTERIOR CONSTRUCTION DETAILS |
| CVR - GENERAL INFORMATION |
| T-001 - OUTLINE SPECIFICATION |
| T-002 - OUTLINE SPECIFICATION |
| Devil's Gate_Central_jleverson@galambosarchitects.net - Sheet - A-201 - EXTERIOR ELEVATIONS.pdf |
| Sheets |
| A-001 - SITE PLAN |
| A-101 - PLANS |
| A-201 - EXTERIOR ELEVATIONS |
| A-301 - BUILDING SECTIONS/DOOR SCHEDULE |
| A-501 - EXTERIOR CONSTRUCTION DETAILS |
| CVR - GENERAL INFORMATION |
| T-001 - OUTLINE SPECIFICATION |
| T-002 - OUTLINE SPECIFICATION |
| Devil's Gate_Central_jleverson@galambosarchitects.net - Sheet - A-301 - BUILDING SECTIONS-DOOR SCHEDULE.pdf |
| Sheets |
| A-001 - SITE PLAN |
| A-101 - PLANS |
| A-201 - EXTERIOR ELEVATIONS |
| A-301 - BUILDING SECTIONS/DOOR SCHEDULE |
| A-501 - EXTERIOR CONSTRUCTION DETAILS |
| CVR - GENERAL INFORMATION |
| T-001 - OUTLINE SPECIFICATION |
| T-002 - OUTLINE SPECIFICATION |
| Devil's Gate_Central_jleverson@galambosarchitects.net - Sheet - A-501 - EXTERIOR CONSTRUCTION DETAILS.pdf |
| Sheets |
| A-001 - SITE PLAN |
| A-101 - PLANS |
| A-201 - EXTERIOR ELEVATIONS |
| A-301 - BUILDING SECTIONS/DOOR SCHEDULE |
| A-501 - EXTERIOR CONSTRUCTION DETAILS |
| CVR - GENERAL INFORMATION |
| T-001 - OUTLINE SPECIFICATION |
| T-002 - OUTLINE SPECIFICATION |
File details come from the government source that posted it. Updated .