Construction Document Section 4.pdf
PDF 18 MB Posted
- Attached to
- Y1DA--590-210 Construct Prosthetics Facility (VA-23-00044335) Federal contract opportunity
- Solicitation number
- 36C77623R0166_1
About this file
This document provides details on a federal solicitation for construction services. The solicitation number 36C77623R0166_1 was issued by the Department of Veterans Affairs Technology Acquisition Center Austin to construct a Prosthetics Facility at an estimated total cost between $10-25 million. Responses are due by April 15th, 2023 with award anticipated by June 30th, 2023. The opportunity is set aside for Service-Disabled Veteran-Owned Small Businesses. The selected contractor will be responsible for all aspects of building construction in accordance with the specifications provided in the 18MB Construction Document Section 4.pdf file.
View the file
Other files for this federal contract opportunity
Show all 37
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NO SUBSCRIPT
EXTEND ENTIRE
PARTITION TO
UNDERSIDE OF
STRUCTURE
FLOOR
CEILING
BOTTOM
OF FLOOR
OR DECK
(D) SUBSCRIPT
EXTEND STUDS TO
DECK, EXTEND
GYPSUM BOARD TO
6" ABOVE HIGHEST
ADJACENT CEILING
6"
(C) SUBSCRIPT
EXTEND ENTIRE
PARTITION TO 6"
ABOVE HIGHEST
ADJACENT
CEILING
6"
(U) SUBSCRIPT
EXTEND ENTIRE
PARTITION TO
UNDERSIDE OF
CEILING
(X'-X") SUBSCRIPT
INDICATES
FINISHED
PARTITION HEIGHT
IN
S
UB
SC
RI
PT
HE
IG
HT
A
S
IN
DI
CA
TE
D
GENERAL NOTES:
1. FOR PARTITIONS WITH UNEQUAL LAYERS OF GYPSUM BOARD ON EACH SIDE, THE SIDE OF THE PARTITION
WITH THE TAG INDICATES WHERE THE EXTRA LAYER(S) OF GYPSUM BOARD ARE TO BE INSTALLED. REFER
TO PARTITION TYPES FOR MORE INFORMATION
2. DIMENSIONS TO METAL STUD PARTITIONS ARE MEASURED TO FINISH FACE UNLESS NOTED OTHERWISE
3. AT INFILL WITHIN OR EXTENSIONS ONTO EXISTING PARTITIONS, THE PARTITION TAG NOTED IS FOR INTENT
ONLY. FINISHED PARTITION FACES ARE TO ALIGN WITH ADJACENT EXISTING PARTITION FACES
4. SUBSCRIPTS MAY BE USED WITH ANY PARTITION TYPE
3'-0"UCD
A6
XN2 XN3 XP2 XP3
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
3 5/8" METAL STUD
FRAMING
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
6" METAL STUD FRAMING
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
3 5/8" METAL STUD
FRAMING
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
6" METAL STUD FRAMING
3" SOUND ATTENUATING
INSULATION
3" SOUND ATTENUATING
INSULATION
(1 ) LAYER 5/8" GYPSUM
BOARD
2 1/2" METAL STUD
FRAMING
(1 ) LAYER 5/8" GYPSUM
BOARD
3 5/8" METAL STUD
FRAMING
3" SOUND ATTENUATING
INSULATION
1 1/2" SOUND
ATTENUATING INSULATION
(1 ) LAYER 5/8" GYPSUM
BOARD
2 1/2" METAL STUD
FRAMING
(1 ) LAYER 5/8" GYPSUM
BOARD
3 5/8" METAL STUD
FRAMING
STC 49 STC 49STC 46 STC 46
4 7/8" 7 1/4" 4 7/8" 7 1/4"
4 1/4"3 1/8"4 1/4"3 1/8"
MA8
7 5/8"
8" CMU
STC 44-49
A3 B3 B6B3bs
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
3 5/8" METAL STUD
FRAMING
3" SOUND ATTENUATING
INSULATION
UP TO 1HR FIRE & SMOKE RATING
UL DESIGN U419
STC 49
4 7/8"
B6bs
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
6" METAL STUD FRAMING
3" SOUND ATTENUATING
INSULATION
UP TO 1HR FIRE & SMOKE RATING
UL DESIGN U419
STC 49
7 1/4"
XN1
(1 ) LAYER 5/8" GYPSUM
BOARD
1 5/8" METAL STUD
FRAMING
2 1/4"
XN6
(1 ) LAYER 5/8" GYPSUM
BOARD
6" METAL STUD FRAMING
6 5/8"
1iH6b
6 1/2"
(1 ) LAYER 5/8" GYPSUM
BOARD
6" COLD FORMED
METAL CH STUD 18GA
@ 16" OC
(1) LAYER OF 1" FIRE
RATED SHAFT LINER PANEL
UP TO 1 HR FR
UL415
STC 40-44
3" SOUND
ATTENUATING
INSULATION
XP3a
(1 ) LAYER 5/8" GYPSUM
BOARD
3 5/8" METAL STUD
FRAMING
3" SOUND ATTENUATING
INSULATION
4 1/4" SMOKE TIGHT
B3a
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
3 5/8" METAL STUD
FRAMING
3" SOUND ATTENUATING
INSULATION
SMOKE RATING
STC 49
4 7/8"
1iMA12
11 5/8"
12" CMU
STC 48-53
XN10
(1 ) LAYER 5/8" GYPSUM
BOARD
10" COLD FORMED METAL
STUD FRAMING - SEE
STRUCTURAL
10 5/8"
PARTITION GENERAL NOTES:
1. SEE LIFE SAFETY PLANS FOR REQUIRED PARTITION FIRE RATINGS.
2. GYPSUM BOARD AND METAL STUDS USED IN FIRE RATED SEPARATION PARTITIONS SHALL
EXTEND FROM FLOOR TO UNDERSIDE OF STRUCTURE, UNLESS NOTED OTHERWISE.
3. WHERE SMOKE PARTITIONS ARE REQUIRED BY LIFE SAFETY PLANS, THE FOLLOWING APPLIES
TO ALL NON-ACOUSTICAL TYPE SMOKE PARTITIONS: EXTEND GYPSUM BOARD ON CORRIDOR
SIDE TO STRUCTURE ABOVE. SEAL TOP AND BOTTOM OF PARTITION AND ALL PENETRATIONS
THROUGH PARTITION ON CORRIDOR SIDE WITH A SMOKE SEALANT HAVING A MINIMUM WARM
SMOKE TEMPERATURE OF 400 DEGREES FAHRENHEIT. ALL SEALS MUST HAVE PRE-APPROVAL
OF CODE OFFICIAL. ROOM SIDE GYPSUM BOARD CAN EXTEND TO 6" ABOVE FINISHED CEILING.
4. CONTRACTORS TO VERIFY CONDITIONS ABOVE CEILING AT EXISTING PARTITIONS IDENTIFIED
WITH FIRE/SMOKE PARTITION SYMBOLS. REPAIR CONDITIONS THAT DO NOT MEET
REQUIREMENTS OF THE INDICATED FIRE/SMOKE RATING SHOWN, SUCH AS BUT NOT LIMITED
TO OPENINGS IN PARTITIONS, GAPS AROUND DUCTWORK, PIPES AND CONDUIT, MISSING
SMOKE DAMPERS, ETC
5. DIMENSIONS TO METAL STUD PARTITION ARE MEASURED TO FINISH FACE OF PARTITION
UNLESS NOTED OTHERWISE
6. THE DIMENSION SHOWING THE LOCATION OF A DOOR FRAME IN GYPSUM BOARD WALLS IS TO
THE INSIDE OF THE DOOR FRAME (DOOR OPENING). PROVIDE 4" TYPICAL DIMENSION IF NO
DIMENSION IS SHOWN.
7. SOUND ATTENUATING INSULATION MEANS GLASS FIBER OR MINERAL WOOL BATTS OR
BLANKETS BEARING THE UL LABEL FOR FIRE RESISTANCE. VERIFY TYPE AND DENSITY (PCF)
WITH FIRE TEST NUMBER SHOWN ON PARTITION TYPE.
8. FOR PARTITION HEIGHTS SEE PARTITION TAG LEGEND AND TAG SUBSCRIPTS ON PLANS.
9. ALL FURRING TO BE PARTITION TYPE XP3, ALL PARTITIONS ARE TO BE PARTITION TYPE B3, UNLESS NOTED OTHERWISE.
10. FOR PARTITION TYPES WITH GYPSUM BOARD ON ONE SIDE ONLY, INSTALL GYPSUM BOARD
ON ROOM SIDE, UNLESS NOTED OR DETAILED OTHERWISE. FOR SHAFTWALL PARTITION
TYPES, INSTALL LINER PANEL ON NON-ACCESSIBLE SIDE, UNLESS NOTED OR DETAILED
OTHERWISE.
11. PROVIDE 1/2" DEFLECTION SPACE AT THE TOP OF STUDS AT ALL PARTITIONS EXTENDING TO
STRUCTURE, UNLESS NOTED OTHERWISE.
12. WHEN GYPSUM BOARD PARTITIONS ARE LOCATED BELOW STRUCTURE THAT HAS A
VERTICAL DEFLECTION MOVEMENT MORE THAN 1/2", PROVIDE PARTITION HEADS WITH
VERTICAL MOVEMENT CAPABILITY TO MATCH THAT DEGREE OF MOVEMENT. MAINTAIN THE
REQUIRED FIRE RATING OF FIRE RATED PARTITIONS FROM FLOOR TO STRUCTURE ABOVE
WITH FIRE TESTED HEAD CONSTRUCTION.
13. WHEN PARTITION FRAMING RUNS HIGHER THAN 12'-0" ABOVE FINISH FLOOR, BRACE
PARTITION BACK TO STRUCTURE ABOVE WITH METAL STUDS EVERY 4'-0" ON CENTER
MINIMUM.
14. BULKHEAD FRAMING SHALL EXTEND TO UNDERSIDE OF STRUCTURE WITH DIAGONAL STUD
FRAMING BRACES AT 4'-0" ON CENTER (2 BRACES MINIMUM) WITH GYPSUM BOARD EXTENDING
6" ABOVE CEILING MINIMUM, UNLESS NOTED OTHERWISE.
15. GENERAL CONTRACTOR SHALL PROVIDE AND COORDINATE ALL IN-WALL BLOCKING FOR
WALL MOUNTED CASEWORK AND EQUIPMENT SUPPLIED BY THIS CONTRACT, OWNER
FURNISHED OR BY VENDORS. CONTRACTORS OPTION TO PROVIDE 3/4" FIRE TREATED
PLYWOOD OR SHEET METAL BLOCKING FOR WALL MOUNTED EQUIPMENT, CASEWORK, DOOR
STOPS, ACCESSORIES, ETC, UNLESS NOTED OTHERWISE.
16. IN WET AREAS SUCH AS BUT NOT LIMITED TO SHOWER, TUB, GLASS WASHING ROOMS,
SOILED UTILITY ROOMS, JANITOR CLOSETS, COMMERCIAL FOOD PROCESSING ROOMS, ETC,
USE TILE BACKER BOARD BEHIND THE CERAMIC TILE AND EXTEND TO 2'-0" BEYOND ALL SIDES
OF THE PLUMBING FIXTURE. IN DOUBLE LAYER WALLS WHERE THE TILE BACKER BOARD IS
INSTALLED OVER A BASE LAYER OF GYPSUM BOARD, APPLY A WATER BARRIER (BUILDING
WRAP) NOT A VAPOR RETARDER, OVER THE BASE LAYER OF GYPSUM BOARD. IN HIGH
HUMIDITY AREAS SUCH AS SAUNAS, STEAM ROOMS AND SWIMMING POOLS, WHERE WALLS
ARE EXPOSED TO CONSTANT MOISTURE, USE TILE BACKER BOARD BEHIND CERAMIC TILE.
17. IN WET AREAS SUCH AS SOILED UTILITY ROOMS, JANITOR CLOSETS, ETC, USE 5/8" WATER
RESISTANT GYPSUM BOARD OR 5/8" FR WATER RESISTANT GYPSUM BOARD.
18. FOR ALL REMODELING PROJECTS, ALL PARTITIONS NOTED AT INFILLS WITHIN, OR
EXTENSIONS ONTO EXISTING PARTITIONS, ARE NOTED AS SUCH FOR INTENT ONLY. ALL
EXPOSED PARTITION FACES ARE TO ALIGN.
NOTE:
WHERE LIFE SAFETY PLANS SHOW A
PARTITION IS RATED, THE PARTITION
WITH THE HIGHEST RATING WILL BE
CONTINUOUS.
NON-RATED
PARTITION PER LIFE
SAFETY PLAN
1 HOUR RATED PARTITION
PER LIFE SAFETY PLAN
2 HOUR RATED PARTITION
PER LIFE SAFETY PLAN
1 HOUR RATED PARTITION
PER LIFE SAFETY PLAN
SB1 FC1
WALL ASSEMBLY
4" FACEBRICK
2" AIR SPACE
3" RIGID INSULATION
BUILDING MEMBRANE
5/8" GYPSUM SHEATHING
6" STUDS - SEE STRUCTURAL
5/8" GPBD
MASONRY TIE
7 1/4" 8 5/8"
1'-3 7/8"
10 1/4" 5 3/4"
1'-4"
WALL ASSEMBLY
5/16 FIBER CEMENT BOARD
5/8" FIRE TREATED PLYWOOD
AIR SPACE
3" RIGID INSULATION
BUILDING MEMBRANE
5/8" GYPSUM SHEATHING
6" STUDS - SEE STRUCTURAL
5/8" GPBD
3/4"
1/4"
1 3 /4"
1/2 " 1/2
2 1/2" 2 5/8"
5 1/8"
SILL PROFILE
9 1
/8"
3 5/8"
CAST STONE BAND PROFILE
2 3 /4"
CAST STONE PARAPET CAP PROFILE
EQ EQ
5" 1"
3/4" 1/4"
1'-11"
SPLIT TAIL ANCHOR BEYOND.
ACOUSTIC PARTITION GENERAL
NOTES:
1. USE ACOUSTICAL SEALANT AT ALL GPBD PARTITION PENETRATIONS AND JOINTS SUCH AS
THE STRUCTURE ABOVE, FLOOR SURFACES AND PARTITIONS CONSTRUCTED OF ANOTHER
MATERIAL, UNLESS NOTED OTHERWISE.
2. ALLOW MINIMUM 1/8" SPACE BETWEEN ELECTRICAL BOX AND GPBD, FILL GAP WITH
ACOUSTICAL SEALANT.
3. BEFORE INSTALLING GPBD PANELS OR SOUND ATTENUATION INSULATION, APPLY MINIMUM
1/16" THICKNESS OF ACOUSTICAL SEALANT OVER KNOCKOUTS OR OTHER SMALL HOLES IN
THE ELECTRICAL BOXES TO INSURE THAT THEY ARE AIR TIGHT. IF A KNOCKOUT IS MISSING, WRAP WITH TAPE AND COVER WITH ACOUSTICAL SEALANT TO AT LEAST 1/8" THICK. INSPECT
BACK SEALING OF BOXES BEFORE THE SOUND ATTENUATION INSULATION AND GPBD
PANELS ARE INSTALLED.
4. WHEN SOUND ATTENUATION INSULATION (SA INS) IS USED, IT MUST NOT CONTACT THE
GPBD MOUNTED ON THE RESILIENT CHANNEL SIDE OF PARTITION AS THE LISTED SOUND
ATTENUATION VALUE WILL BE COMPROMISED.
5. LOCATE OUTLETS IN ALTERNATE STUD CAVITIES AND USE SEPARATE CONDUIT FOR
OUTLETS ON OPPOSITE SIDE OF THE SAME PARTITION.
6. ELECTRICAL BOXES CAN BE RIGIDLY MOUNTED TO STUDS WITH STANDARD MOUNTING
BRACKETS. DO NOT ALLOW BOX, MOUNTING BRACKETS OR CONDUIT TO TOUCH THE
RESILIENT CHANNELS. ELECTRICAL BOXES ARE NOT PERMITTED IN WALLS EXCEEDING A
TWO HOUR FIRE RATING UNLESS WALLS ARE SO TESTED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
C U s e rs
\P u b lic \D o c u m e n ts \R e v it P ro je c ts
\1
-R g b a rb a ri a e -m n .c o m
.r v t
/8
/2
:2
:4
A
M
AE601
WALL & PARTITION TYPES AND
DETAILS
CONSTRUCT
PROSTHETICS FACILITY
HAMPTON, VA.
590-210
09/02/2022 LA GJB16149
TYPES - PARTITION
GUIDELINE - RATED WALL INTERSECTIONS
TYPES - WALL
ARCHITECTURAL PRECAST PROFILES
Revisions: Date: 09/12/2022
I hereby certify that this plan, specification, or report was prepared by me, or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name: Steve Schlotthauer
Signature:_________________
Date:__________ License# 42138
PANEL PREFIXES
AL- ALUMINUM
CG- COILING GRILLE
CS- COILING SLATS
HM- HOLLOW METAL
OS- OVERHEAD SECTIONAL
RD3- REVOLVING DOOR 3 PANEL
RD4- REVOLVING DOOR 4 PANEL
VL- VERTICAL LIFT
WD- WOOD
AG ALL GLASS
BF BIFOLD
BFG BIFOLD GLASS
D DUTCH
DG DUTCH GLASS
DS DUTCH W/SHELF
F FLUSH
G2 GLASS 2 LIGHT
G3 GLASS 3 LIGHT
GF GLASS FULL
GH GLASS HALF
LF LOUVER FULL
LGH LOUVER GLASS HALF
LH LOUVER HALF
HM-GF
FRAME PREFIXES
0 FRAMED-CASED OPENING
1 DOOR ONLY
2 SIDELIGHT(S) 1 SIDE
3 SIDELIGHT(S) 1 SIDE W/HORIZONTAL
4 SIDELIGHT(S) BOTH SIDES
5 SIDELIGHT(S) BOTH SIDES W/HORIZONTAL
6 DOOR W/TRANSOM
7 DOOR W/TRANSOM W/SIDELIGHT(S) 1 SIDE
8 TRANSOM W/SIDELIGHT(S) 1 SIDE W/HORIZONTAL
9 TRANSOM W/SIDELIGHT(S) BOTH SIDES
10 TRANSOM W/SIDELIGHT(S) BOTH SIDES W/HORIZONTAL
11 FULL WIDTH TRANSOM W/SIDELIGHT(S) 1 SIDE
1X1 1 LIGHT WIDE AND 1 LIGHT HIGH
2X2 2 LIGHTS WIDE AND 2 LIGHTS HIGH
3X3 3 LIGHTS WIDE AND 3 LIGHTS HIGH
(NOTE: OTHER COMBINATIONS POSSIBLE)
OX FIXED PANEL, ACTIVE PANEL
OXO FIXED PANEL, ACTIVE PANEL, FIXED PANEL
OXX FIXED, ACTIVE, ACTIVE
OXXO FIXED, ACTIVE, ACTIVE, FIXED
OXXXXO FIXED, ACTIVE, ACTIVE, ACTIVE, ACTIVE, FIXED
HMS-2
LNV LOUVER NARROW VISION
NV NARROW VISION
NV2 NARROW VISION 2 LIGHT
NV3 NARROW VISION 3 LIGHT
NVC NARROW VISION CENTERED
RP2 RAISED PANEL 2 PANEL
RP4 RAISED PANEL 4 PANEL
RP6 RAISED PANEL 6 PANEL
RP8 RAISED PANEL 8 PANEL
V VISION
W WINDOWS (1 ROW)
WT WINDOWS THROUGHOUT
DOOR PANEL NAMING
DOOR FRAME NAMING NOTE: ACTUAL FRAMES MAY VARY FROM DESCRIPTIONS
BELOW, REFER TO FRAME TYPE ELEVATIONS
NOTE: ACTUAL PANELS MAY VARY FROM DESCRIPTIONS
BELOW, REFER TO PANEL TYPE ELEVATIONS
PANEL SUFFIXES
AL- ALUMINUM
AL-BL- ALUMINUM BORROWED LIGHT
AL-SL- ALUMINUM SLIDING
ALR- ALUMINUM REVOLVING
CW## CURTAINWALL
HMM- HOLLOW METAL MASONRY
HMM-BL- HMM BORROWED LIGHT
HMM-DE- HMM DOUBLE EGRESS
HMS- HOLLOW METAL STUD
HMS-BL- HMS BORROWED LIGHT
HMS-DE- HMS DOUBLE EGRESS
OC- OVERHEAD COILING
OS- OVERHEAD SECTIONAL
VL- VERTICAL LIFT
WD- WOOD
WD-BL- WOOD BORROWED LIGHT
WDP- WOOD POCKET
FRAME SUFFIXES
ISOMETRIC DETAIL
VERTICAL STUDS @ 2' - 0" MAX
W/ GYPSUM BD 1' - 4" W/ GYPSUM LATH &
PLASTER DOUBLE STUDS FOR SUPPORTING CONC
BACKER BOARD
PROVIDE CONTINUOUS BRACING WHEN STUDS
EXCEED 10' - 0" & ARE FINISHED BOTH SIDES
JAMB ANCHOR CLIPS 3 PER SIDE -
COORDINATE W/ HINGE REINFORCEMENT
NOTE 1:
OMIT BRACE WHEN "D" DIMENSION IS LESS THAN 2' - 0"
FOR GYP WALL BD. OR 16" FOR PLASTER PARTITION.
CRIPPLE STUD
DO NOT ANCHOR TO
BEARING STUD
GYP BD PANELS
CONTROL
JOINT
PROVIDE SOUND
DEADENING
WHERE REQ'D.
ISOMETRIC OF CONSTRUCTION JOINT.
SECTION A DETAIL C
JAMB ANCHORS
(FURNISHED WITH FRAME)
DETAIL D
DOUBLE STUDS
JAMB ANCHOR
SHIM AS
REQ'D
METAL
ANCHOR CLIP
METAL DOOR
FRAME
SANITARY STOP
WHERE REQ'D
SEC B
CONTROL JOINT
BOTH SIDES OF
PARTITION
6" M
AX
DETAIL D
SEE DOOR SCHEDULE
VARIES
SHIM AS REQ'D
DETAIL C
VA
RI
ES
EQ
EQEQ
EQ
D
RUNNER
BET.
STUDS
MTL
DOOR
FRAME
A A
1/2" MIN
1/2 " M
IN
SECTION B
STUDWIDTH
FRAME FACE
MINUS 3/16"
3/4 " M
IN
JAMB DEPTH
MINUS 3/16"
FRAME FACE
MINUS 3/16"3/4
" M
IN
1/2" MIN
5/8" MAX
STUDWIDTH
3/4 " M
IN
GYPSUM
CONTROL JOINT
@ DOOR HEADS
FINISHED
FLOOR
HM-F
WD-F
AL-NV
WD-NV
HM-GH
WD-GH
WD-GF
WIDTH
OPENING
OP
EN
IN
G
HE
IG
HT
WIDTH
OPENING
WIDTH
OPENING
WIDTH
OPENING
OP
EN
IN
G
HE
IG
HT
OP
EN
IN
G
HE
IG
HT
OP
EN
IN
G
HE
IG
HT
" M
AX
1'- 0"
6"6"
" M
AX
1'- 0"
6" 6"
1'- 0"
AL-GF
WIDTH
OPENING
OP
EN
IN
G
HE
IG
HT
1'- 0"
6" 6"
1'- 0"
FINISHED
FLOOR
HMS-1 HMM-1
OP
EN
IN
G
HE
IG
HT
WIDTH
OPENING
OP
EN
IN
G
HE
IG
HT
WIDTH
OPENING
AL-7
OP
EN
IN
G
HE
IG
HT
FI
ED
V
ER
IF
Y
'-6
FIED VERIFY
OPENING WIDTH
AL-6
OP
EN
IN
G
HE
IG
HT
FI
ED
V
ER
IF
Y
'-4
R 3'- 0"
WIDTH
OPENING
FIED VERIFY
6'-0"
PREFINISHED
INSULATED & BLAST
RESISTANT PANEL
IG-1
IL-1
1" SURFACE APPLIED
MULLIONS. MITER ENDS OF
MULLIONS WHERE THEY
INTERSECT
7'- 2"
5/
8"
3 3 /8"
SEE FOR MUNTIN DETAIL/5 AE602
VARIES
AS
S
CH
ED
METAL STUDS
GYP BD
HM FRAME
DOOR AS SCHED
2"
METAL RUNNER
NOTE:
1. FOR PARTITION TYPES SEE PLANS
2. SEE AE602 FOR FRAME PROFILE INFORMATION.
VARIES
2"
AS
S
CH
ED
HM FRAME
DOOR AS SCHED
METAL STUDS
GYP BD
NOTE:
1. FOR PARTITION TYPES SEE PLANS
2. SEE AE602 FOR FRAME PROFILE INFORMATION.
1. 5/8" AT 20 MINUTE FIRE RATED FRAMES AND NON-RATED FRAMES, 3/4" AT FIRE RATED FRAMES OF 45
MINUTES AND ABOVE.
2. 5/8" AT 20 MINUTE FIRE RATED FRAMES AND NON-RATED FRAMES, 1" AT FIRE RATED FRAMES OF 45
MINUTES AND ABOVE.
3. FOR FRAMES IN GYP BD PARTITIONS, VERIFY THAT THE FRAME THROAT DEPTH MATCHES THE
PARTITION THICKNESS.
4. 5 3/4" AT MASONRY OR DEEP GYP BD WALL RECESSES WHERE FRAME DOES NOT WRAP THE WALL.
FRAME PROFILE NOTES:
FACE OF WALL
HM FRAME
CORRIDOR
SIDE
A
HEAD
HM FRAME
DOOR
- SEE OPENING
SCHEDULE
JAMBS
C
DOOR OR GLAZING / STOP
(SHOWN) AS
SCHEDULED -SEE
OPENING SCHEDULE
ROOM SIDE
B
SEE NOTE 2
ON
P
LA
N
2"
UN
O
TY
PE
SE
E
FR
AM
E
SE
E
NO
TE
TYPES UNO
SEE GYP BD PTN
SEE NOTE 4
SEE GYP BD PTN
5 3/4" AT MASONRY UNO
TYPES UNO
SEE GYP BD PTN
5 3/4" AT MASONRY UNO
TY
PE
SE
E
FR
AM
E
TYPES UNO
SEE GYP BD PTN
5 3/4" AT MASONRY UNO
TY
PE
SE
E
FR
AM
E
HM FRAME
DOOR
- SEE OPENING
SCHEDULE
3 3 /8"
R 2'-10"
R 2'-2 5/8"
R 1'-
7 5 /8"
R 1'-0 5/8"
R 1'-0 5/8"
30.00°
30.
00°
.00
MITER MUNTINS AT INTERSECTIONS
R 5 5/8"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
C U s e rs
\P u b lic \D o c u m e n ts \R e v it P ro je c ts
\1
-R g b a rb a ri a e -m n .c o m
.r v t
/8
/2
:2
:4
A
M
AE602
DOOR SCHEDULE AND
ELEVATIONS
CONSTRUCT
PROSTHETICS FACILITY
HAMPTON, VA.
590-210
09/02/2022 LA GJB16149
OPENING SCHEDULE
ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION
HD
W
G
RO
UP
FI
RE
LA
BE
L (
MI
N)
GA
SK
ET
EL
EC
TR
IC
AL
S
LA
BE
L
COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT
PANEL
TYPE
2ND
PANEL
TYPE
PANEL
GLAZING FRAME TYPE
FRAME
GLAZING
LOBBY 100-45 6'-0" 7'-0" AL-GF AL-GF LG-2 AL-6 IL-1 1.0 Y Y CLOSER, INSULATED, BLAST
RESISTANT
CORRIDOR RECEPTION 101-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 15.0
CORRIDOR PATIENT TOILET 102-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 17.0
CORRIDOR FITTING / EXAM SOFT GOODS 103-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0
CORRIDOR FITTING / EXAM SOFT GOODS 104-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0
CORRIDOR FITTING / EXAM SOFT GOODS 105-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0
CORRIDOR FITTING / EXAM SOFT GOODS 106-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0
CORRIDOR FITTING / EXAM SOFT GOODS 107-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0
CORRIDOR FITTING / EXAM SOFT GOODS 108-45 3'-6" 7'-0" WD-NV MG-1 HMS-1 NONE 19.0
CORRIDOR FACIAL/ BODY FITTING STUDIO 109-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0
CORRIDOR HAC 110-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 12.0
CORRIDOR STAFF TOILET 111-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 16.0
CORRIDOR SOILED HOLDING 112-45 3'-6" 7'-0" WD-NV MG-1 HMS-1 NONE 14.0 Y Y
CORRIDOR DYNAMIC ALIGNMENT 113-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0
CORRIDOR CAST 114-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0
CORRIDOR EQUIPMENT STORAGE 115-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 6.0 Y Y CLOSER
CORRIDOR FITTING / EXAM SOFT GOODS 116-45 4'-0" 7'-0" WD-F NONE HMS-1 NONE 19.0
CORRIDOR FITTING / EXAM CUSTOM FAB 117-45 4'-0" 7'-0" WD-F NONE HMS-1 NONE 19.0
CORRIDOR PATIENT / PUBLIC TOILET 118-45 3'-8" 7'-0" HM-F NONE HMM-1 NONE 18.0 CLOSER, BLAST RESISTANT CORRIDOR PATIENT / PUBLIC TOILET 119-45 3'-8" 7'-0" HM-F NONE HMM-1 NONE 18.0 CLOSER, BLAST RESISTANT CORRIDOR TEAM EVALUATION 120A-45 4'-0" 7'-0" HM-F NONE HMS-1 NONE 10.0 CLOSER, 14GA VERTICALLY
STIFFENED
CORRIDOR TEAM EVALUATION 120B-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 19.0
CORRIDOR STAFF TOILET 122-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 16.0
CORRIDOR ELECTRICAL 124-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 11.0
CORRIDOR MECHANICAL FIRE/H20 125-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 12.0
CORRIDOR ORTHO SUPERVISOR OFFICE 126-45 3'-0" 7'-0" WD-NV MG-1 HMS-1 NONE 15.0
CORRIDOR PROSTHETICS LAB 130A-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 9.0 CARD READER, CLOSER, GASKET, POWER OPERATOR
LAB DUST ROOM PROSTHETICS LAB 130B-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 20.0
PROSTHETICS/ ORTHOTICS FUME PROSTHETICS LAB 130C-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 20.0
CAD/ CAM PROSTHETICS LAB 130D-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 21.0
CORRIDOR ELECTRICAL 150-45 3'-0" 7'-0" HM-F NONE HMM-1 NONE 13.0 CLOSER, BLAST RESISTANT CORRIDOR TELECOM 151-45 3'-0" 8'-0" HM-F NONE HMS-1 NONE 10.0 45 Y Y Y CARD READER, CLOSER, GASKET, BLAST RESISTANT, 14GA
VERTICALLY STIFFENED
CORRIDOR CONFERENCE 202-45 3'-6" 7'-0" WD-NV MG-1 HMS-1 NONE 21.0
STAFF LOUNGE LOCKERS 203A-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 22.0
CORRIDOR STAFF LOUNGE 203B-45 3'-6" 7'-0" WD-NV MG-1 HMS-1 NONE 22.0
CORRIDOR CHIEF OFFICE 204-45 3'-0" 7'-0" WD-NV MG-1 HMS-1 NONE 15.0
CORRIDOR ASSIST CHIEF OFFICE 205-45 3'-0" 7'-0" WD-NV MG-1 HMS-1 NONE 15.0
CORRIDOR PROSTHETICS REP OFFICE 206-45 3'-0" 7'-0" WD-NV MG-1 HMS-1 NONE 15.0
CORRIDOR STAFF TOILET 208-45 3'-0" 7'-0" WD-NV MG-1 HMS-1 NONE 12.0
CORRIDOR MECHANICAL 220A-45 6'-0" 7'-0" WD-F WD-F NONE HMS-1 NONE 7.0
CORRIDOR MECHANICAL 220B-45 3'-0" 7'-0" WD-F MG-1 HMS-1 NONE 12.0
CORRIDOR TELECOM 221-45 3'-0" 8'-0" WD-F NONE HMS-1 NONE 10.0 45 Y Y CARD READER, CLOSER, GASKET
CORRIDOR ELEVATOR EQUIP 222-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 12.0
CORRIDOR PARTS STORAGE 223-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 14.0
CORRIDOR SHOE MODIFICATION STORAGE 224-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 14.0
CORRIDOR WHEELCHAIR PARTS STORAGE 225-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 14.0
CORRIDOR DME ACTIVE STORAGE 226-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 14.0
CORRIDOR ELECTRICAL 227-45 3'-0" 7'-0" WD-F MG-1 HMS-1 NONE 12.0
CORRIDOR PROSTHETICS/ ORTHOTICS
MAINTENANCE
228-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 14.0
TRASH PROSTHETICS LAB 1303-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 12.0
PROSTHETICS LAB CORRIDOR C100A-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 10.0 CARD READER, CLOSER, GASKET, BLAST RESISTANT, 14GA
VERTICALLY STIFFENED
CORRIDOR CORRIDOR C100B-45 3'-8" 7'-0" HM-F NONE HMM-1 NONE 5.0 CLOSER, BLAST RESISTANT, 14GA
VERTICALLY STIFFENED
CORRIDOR CORRIDOR C100C-45 3'-10" 7'-0" WD-GF MG-1 HMS-1 NONE 23.0 Y Y POWER OPERATOR, INSULATED CORRIDOR C101-45 3'-10" 7'-2" AL-GF MG-1 AL-1 NONE 14.0 Y CARD READER, CLOSER, GASKET, BLAST RESISTANT
CORRIDOR STAIR 2 C101-64 3'-6" 7'-0" WD-F NONE HMS-1 NONE 4.0 60 Y Y
CORRIDOR CORRIDOR C103-45 3'-0" 7'-0" HM-F NONE HMM-1 NONE 8.0 CARD READER, CLOSER, GASKET, BLAST RESISTANT
CORRIDOR STAIR 1 S100A-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 3.0 60 Y Y Y
STAIR 1 S100B-45 3'-6" 7'-0" AL-NV LG-2 AL-7 NONE 2.0 CARD READER, CLOSER, INSULATED
DOOR
CORRIDOR STAIR 2 S102A-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 4.0 60 Y Y
STAIR 2 S102B-45 3'-6" 7'-0" AL-NV LG-2 AL-7 NONE 2.0 CARD READER, CLOSER, INSULATED
DOOR
CORRIDOR STAIR 1 S201-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 3.0 60 Y Y
CORRIDOR STAIR 2 S202-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 3.0 60 Y Y
CORRIDOR WORKSTATION B227-110 3'-0" 7'-0" WD-NV MG-1 HMS-1 NONE 15.0 BUILDING 110 DEDUCT ALTERNATE
1 1/2" = 1'-0"1 TYPICAL PARTITION CONTROL JOINT FRAMING AT DOORS
TYPES - PANELS
TYPES - FRAMES
1 1/2" = 1'-0"2 HM DOOR FRAME IN METAL STUD PARTITION - HEAD
1 1/2" = 1'-0"3 HM DOOR FRAME IN METAL STUD PARTITION - JAMB
3" = 1'-0"4 HM FRAME PROFILES.
3/4" = 1'-0"5 AL-7 MUNTIN DETAIL
Revisions: Date: 09/12/2022
I hereby certify that this plan, specification, or report was prepared by me, or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name: Steve Schlotthauer
FIRST LEVEL
0"
W21CW1
5'-4" MO
'-2
" M O
2'- 0"
6'- 8"
EQ EQ
IL-1
IL-1
IL-2
IL-1
3'- 6"
4'- 6"
M O
3'-8" MO
BLAST
RESISTANT
CURTAIN WALL
FRAME
C3
C2
C3
C1C1
C1
C1
W8
W6
W1 W1
SECOND LEVEL
14'-0"
W20W16
IL-1
W5
W1
EX
IS
TI
NG
7'-
" M O
3'-8"MO
2'- 0"
8'- 0"
3'-8" MO
EQ
EQ
EQ
EQ
W6
W4
W2
IL-1
W5
W1
W6
W4
W2
FIRST LEVEL
0"
W1 W4
2'-8" MO
EQ
EQ
EQEQ
2'- 2"
6'-
"9'- 1"
M O
EX
IS
T
9'- 4"
M O
EX
IS
T
2'- 2"
7'- 2"
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
3'-8" MO
EQ EQ EQ
EQ
EQ
EQ
EQ
EQ
EQ
W4
W2W3
W6
W1 W5
IL-1
IL-2 WHERE INDICATED
ON FLOOR PLANW7
W4
W2W3
W6
W1
W5
IL-1W7
FIRST LEVEL
0"
W2
9'- 1"
M O
EX
IS
T
6'-
2'-
2"
3'-8" MO
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ EQ EQ
W4
W2W3
W6
W1 W5
IL-1W7
3'- 4 1
/2" 3'-
4 1 /2"
2'- 2"
FIRST LEVEL
0"
SECOND LEVEL
14'-0"
W14
W5
EX
IS
T
EX
IS
T
5'- 0"
M O
7'-
" M O
3'-8" MO
3'-8" MO
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQEQEQ
EQ
EQ
EQEQEQ
EQ
EQ
IL-1
W6
W4
W2
W1 W5 W3
W4
W2
W3
W6
W1 W5
IL-1
FIRST LEVEL
0"
W6
3'-
" M O
EX
IS
T
EQ
EQ
EQ
2'-4" MO
EQ EQ
IL-1
W6
W8
W1
ALL CURTAIN WALL (CW#) SYSTEMS TO BE 7 1/2"D UNLESS NOTED OTHERWISE
ALL 7 1/2" SYSTEM MULLION PROFILES TO BE C1 UNLESS NOTED OTHERWISE.
TOTAL THICKNESS OF CURTAIN WALL MAY VARY, SEE GLAZING TYPES.
CURTAIN WALL NOTES
S1
2" X 4" SYSTEM
LOBBY
INSIDE
OUTSIDE
INSIDE
2"
W1 W2 W3 W4 W5 W6
INSIDEOUTSIDE INSIDEOUTSIDE
INSIDEOUTSIDE
OUTSIDE
INSIDE
OUTSIDE
INSIDE
4"
2" X 4" WINDOW (W#) SYSTEM
INSIDEOUTSIDE
W7
C1
2 1/2" X 7 1/2" SYSTEM
1"
7 1 /2"
C2
OUTSIDE
INSIDE
1"
7 1 /2"
C3
4" OUTSIDE
INSIDE
1"
7 1 /2"
6"OUTSIDE
INSIDE
2 1/2"
2 1/2' X 7 1/2" CURTAIN WALL (CW#) SYSTEM
ALL WINDOWS (W#) SYSTEMS TO BE 4"D UNLESS NOTED OTHERWISE
4" SYSTEM MULLION PROFILES
- SILLS TO BE W4 UNLESS NOTED OTHERWISE
- HEAD TO BE W6 UNLESS NOTED OTHERWISE
- DIVIDED LIGHT MUNTIN TO BE W3 UNLESS NOTED OTHERWISE.
WINDOW NOTES
3/4"
4"
3 9 /16
2 3 /8"
4"4"2"2"
2"
1"
W8
INSIDEOUTSIDE
2"
4"
C4
OUTSIDE
INSIDE
1"
7 1 /2"
8"
C5
OUTSIDE
INSIDE
1"
7 1 /2"
9"
S2
4" X 4" SYSTEM
LOBBY
INSIDE
4"
1"
FIRST LEVEL
0"
W8
EX
IS
T 5'-
0" M
O
3'-8" MO
IL-1
W1
W6
W8
W1
SECOND LEVEL
14'-0"
W10
8'- 0"
M O
EX
IS
T
3'-8" MO
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ EQ EQ
W4
W2
W6
W1
IL-1
W5
W3
SECOND LEVEL
14'-0"
W15
7'-
" M O
EX
IS
T
3'-8" MO
EQ EQ EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
W4
W2
W6
W1
IL-1
W5
W3
SECOND LEVEL
14'-0"
CW2 W9 W12
CW3
FIELD VERIFY
5'-0" MO
4'-
EX
IS
T
ST
ON
E
BA
ND
AL
IG
N W
IT
H
R 2'-6"
8'- 9"
F V
1'- 4"
EQ
EQ
5'-0" MO FV
EQ EQ
8'- 0"
M O
F V
EX
IS
T
EQ
EQ
2'-8" MO FV
EQ EQ
EQ
EQ
EQ
EQ
EQ
EQ
8'- 2"
M O
F V
EX
IS
T
3'-8" MO FV
EQ EQ EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
EQ
W4
W2
W6
W1
IL-1
W5
W3
W4
W2
W6
W1
IL-1
W5
W3
C2
C2
C3
C2IL-1
IL-2 C1 C1
C1
C4IL-2
FIRST LEVEL
0"
SF2
8'- 2"
2'- 8"
4'-
3'- 7"
OPENING FOR SLIDING
WINDOW
1'-3" 3'-2" 3'-6" 1'-0 7/8"
8'-11 7/8"
'-1
0"
4'-
MG-1
S1
(TYP)
FIRST LEVEL
0"
SF3
1'- 3"
2'- 9"
6'-
1'- 3"
9'- 7"
3'-6"
1'-2" 1'-2 5/8"
1'-1 3/8"
'-1
0"
MG-1
S1
(TYP)
S2
FIRST LEVEL
0"
SF1
6'-
4'-
0"
2'-5 3/8" 1'-8" 3'-6" 1'-6 1/4"
9'-1 5/8"
3'- 7"
OPENING FOR SLIDING
WINDOW
'-1
0"
MG-1
S1
(TYP)
SECOND LEVEL
14'-0"
CW19
9'- 0"
22'-2 3/4"
EQ EQ EQ EQ EQ
LG-1
C1
C1
C1
CLCL CL CL CL CL
C1 C1 C1 C1 C1
SECOND LEVEL
14'-0"
TOP OF EXISTING MASONRY
25'-10 3/8"
CW18
'-1
0 3 /8"
1'- 0 3
/4" 4'-
5'-0"
2'- 2 1
/4"
IL-2 C1 C1
C1
C5
IL-2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
C U s e rs
\P u b lic \D o c u m e n ts \R e v it P ro je c ts
\1
-R g b a rb a ri a e -m n .c o m
.r v t
/8
/2
:2
:5
A
M
AE603
CURTAIN WALL, WINDOW TYPES
AND PROFILES
CONSTRUCT
PROSTHETICS FACILITY
HAMPTON, VA.
590-210
09/02/2022 LA GJB/JT16149
1/4" = 1'-0"
EXTERIOR CURTAIN WALL AND WINDOW TYPES
1 1/2" = 1'-0"1 CURTAIN WALL, STOREFRONT AND WINDOW FRAME PROFILES
1/4" = 1'-0"
EXTERIOR CURTAIN WALL AND WINDOW TYPES
1/4" = 1'-0"
INTERIOR STOREFRONT TYPES
1/4" = 1'-0"
INTERIOR CURTAIN WALL TYPES
Revisions: Date: 09/12/2022
I hereby certify that this plan, specification, or report was prepared by me, or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name: Steve Schlotthauer
ACCESSIBLE LAVATORY BASIN/BATHROOMS
CARD READER
GRAB BAR
ACCESSIBLE TOILET/WATER CLOSETS
- SEE ELECTRICAL
AND COMMUNICATION DRAWINGS
MIN
2'-6"
WALL AT RECESS
MA
X
2'-
"T O
RI
M
MA
X
2'-
"T O
RI
M
UN
O
3'- 0"
3'-6"MIN
MAX
1'-0"
7"-9"
"-3 6"
MIN
1'-0"
MIN
2'-0"
"-3
6"
SIDE WALL BACK WALL
LAVATORY
HOUSEKEEPING/EVS CLOSET
UTILITY SHELF
SERVICE
RECEPTOR
WATER CONTROLS
MOP HOLDER
4'- 8"
ACCESSIBLE MIRROR
MOP HOLDER
CLEAR FLOOR SPACE
5'-0"MIN
1. SANITARY NAPKIN DISPOSAL. PROVIDE AT UNISEX, & WOMEN'S PATIENT BATHROOMS ONLY.
2. DISPENSERS MAY NOT BE LOCATED BEHIND GRAB BARS.
1. SEE PLAN FOR SPECIFIC LOCATION CONDITION
2. SDISD & PTC - VC
3. * KNEE CLEARANCE
4. SEE ACCESSIBLE MIRROR AT LAV FOR ADDITIONAL INFORMATION
1. UTILITY SHELF 24" LONG UNO
2. WATER CONTROLS AND SERVICE RECEPTOR - SEE MECHANICAL
1. SEE INTERIOR ELEVATIONS FOR
MIRROR SIZE
WALL AT CORNER
WALL CLOCK
-SEE ELECTRICAL DRAWINGS
CLOCK
ACCESSIBLE SOAP AND
HAND SANITIZER DISPENSER
TO OPERATOR
OV
ER
C
OU
NT
ER
" M
AX
4'- 0"
MA
X
ACCESSIBLE PTD
TO TOWEL
SLOT
4'- 0"
MA
X
OV
ER
C
OU
NT
ER
" M
AX
1'-3 1/2"
EQ EQ
ACCESSIBLE LAV
9"
MI
N*
2'-
"T O
RI
M
MA
X
17"-25" TOE CLEARANCE
2'- 3"
MA
X*
8"MIN*
11"MIN*
25" MAX TO CONTROLS
56" @ WALL HUNG WC**
SND
1'- 3"
MI
N
4'- 0"
MA
X
DISPENSER OUTLET
ZONE
WC
LINE OF CLEAR
FLOOR SPACE
"-1
9"
* AT TOILET COMPARTMENTS
** AT TOILET COMPARTMENTS AND SINGLE OCCUPANCY
PLACE HANDLE ON
OPEN SIDE
16"-18"
" T
O
RE
FL
EC
TI
VE
S
UR
FA
CE
1'-4"
SANITARY NAPKIN DISPOSAL
1. SANITARY NAPKIN DISPOSAL. PROVIDE
AT UNISEX, & WOMEN'S PATIENT
BATHROOMS ONLY.
6'- 0"
3'- 0"
7'- 4"
GRAB BAR
ACCESSIBLE BARIATRIC TOILET/WATER CLOSETS
3'-6"MIN
MAX
1'-0"
7"-9"
"-3
6"
MIN
1'-0"
MIN
2'-0"
"-3
6"
SIDE WALL BACK WALL
CLEAR FLOOR SPACE
5'-0"MIN
1. SANITARY NAPKIN DISPOSAL. PROVIDE AT UNISEX, & WOMEN'S PATIENT BATHROOMS ONLY.
2. DISPENSERS MAY NOT BE LOCATED BEHIND GRAB BARS.
59" @ FLOOR MOUNTED WC
1'- 3"
MI
N
4'- 0"
MA
X
DISPENSER OUTLET
ZONE
WC
LINE OF CLEAR
FLOOR SPACE
"-1
9"
PLACE HANDLE ON
OPEN SIDE
2'-0"
2 GLOVE BOXES SHOWN,
REFER TO ELEV FOR
REQ'D QTY. ADDITIONAL
BOXES MOUNTED ABOVE
4'-6"/1370mm.
PROVIDE PARTITION BLOCKING
SHARPS CONTAINER
UN
O
4'- 6"
GLOVE BOX
ADDITIONAL
GLOVE BOXES
AS REQ'D
FLAT TV SCREEN/ MONITORS PC MOUNTING BRACKET
TV EO
UN
O
7'- 2"
UN
O
6'- 6"
EO & VD
BLOCKING
3'- 0"
EQ
EQ
EQ EQ
ADJUSTABLE
MONITOR
BRACKET
ADJUSTABLE VERTICAL SLIDE
MONITOR BRACKET
WALL PHONE
TEL
4'- 4"
ACCESSIBLE BABY CHANGING
STATION
TO BED HEIGHT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
C U s e rs
\P u b lic \D o c u m e n ts \R e v it P ro je c ts
\1
-R g b a rb a ri a e -m n .c o m
.r v t
/8
/2
:2
:5
A
M
AE640
MOUNTING HEIGHTS CONSTRUCT
PROSTHETICS FACILITY
HAMPTON, VA.
590-210
09/02/2022 LA GJB16149
TYPICAL MOUNTING HEIGHTS
Revisions: Date: 09/12/2022
I hereby certify that this plan, specification, or report was prepared by me, or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name: Steve Schlotthauer
TA
LL
S
TO
RA
GE
C
AB
IN
ET
S
126-45
ORTHO
SUPERVISOR
OFFICE
S102-45
STAIR 2
122-45
STAFF
TOILET
125-45
MECHANICAL
FIRE/H20
C103-45
CORRIDOR
124-45
ELECTRICAL
120-45
TEAM
EVALUATION
C100-45
CORRIDOR
151-45
TELECOM
130E-45
TRASH
130C-45
PROSTHETICS/
ORTHOTICS
FUME130D-45
CAD/ CAM
130B-45
LAB DUST
ROOM
130A-45
LAB
RESTORATION 114-45
CAST
109-45
FACIAL/
BODY
FITTING
STUDIO
111-45
STAFF
TOILET
112-45
SOILED
HOLDING
113-45
DYNAMIC
ALIGNMENT115-45
EQUIPMENT
STORAGE
116-45
FITTING /
EXAM SOFT
GOODS
117-45
FITTING /
EXAM
CUSTOM
FAB
130-45
PROSTHETICS
LAB
108-45
FITTING /
EXAM SOFT
GOODS
S100-45
STAIR 1
107-45
FITTING /
EXAM SOFT
GOODS
106-45
FITTING /
EXAM SOFT
GOODS
105-45
FITTING /
EXAM SOFT
GOODS
104-45
FITTING /
EXAM SOFT
GOODS
103-45
FITTING /
EXAM SOFT
GOODS102-45
PATIENT
TOILET
100-45
LOBBY
101-45
RECEPTION
118-45
PATIENT /
PUBLIC
TOILET
119-45
PATIENT /
PUBLIC
TOILET150-45
ELECTRICAL
123-45
OPEN
OFFICE
C102-45
CORRIDOR
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1 CG1
CG1
CG1
110-45
HAC
CG1
CG1
CG1
C100-45
CORRIDOR
CG1 CG1
FN1 FN1
FN1 FN1
FN1
FN1
FN1
FN3
FN1
FN1
FN1
WP-1
WP-1
WP-1
WP-1
WP-1
WP-1
WP-1
WP-1
WP-1
WP-1
WP-1
WP-1
WP-1
WP-1
WP-1
VWC-2VWC-2
VWC-1
VWC-1VWC-1
WP-2
WP-2
WP-2
WP-2
WP-2
WP-2
VWC-3 VWC-4
VWC-5 VWC-3
WP-2
WP-2
WP-2
WP-2
WP-1
WP-2
VWC-4
VWC-3 WP-2VWC-4
WP-2WP-2
WP-1
WP-1
RWC-1
RWC-1
RWC-1
RWC-1
VWC-2VWC-2
CG1
WP-1
WP-1
1'- 3"
1'- 3"
1'-3"
P-3
P-3
C101-45
CORRIDOR
CG1
CG1
CG1 CG1
CG1
WP-2
WP-2
VWC-5
CG1CG1
RWC-1
RWC-1
CG1CG1CG1CG1CG1CG1 CG1CG1
CG1
CG1
5'- 0"
1. FIELD FINISH VENTS, GRILLES, ACCESS PANELS, PLUG STRIP, BASEBOARD RADIATION
ENCLOSURES, ELECTRICAL PANEL BOARDS (IN FINISHED SPACES AS THEY OCCUR) TO MATCH
SURFACE ON WHICH THEY OCCUR UNLESS OTHERWISE INDICATED. EXCEPTION: ITEMS WITH
FACTORY WHITE FINISH, OCCURRING ON WHITE ACT OR WHITE GYPSUM BOARD CEILING
SHALL NOT BE PAINTED. STAINLESS STEEL ITEMS SHALL NOT BE PAINTED
2. FIELD VERIFY ALL NEW CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO
INSTALLATION
3. LOCATE CHANGES IN FLOOR FINISH MATERIAL UNDER CENTERLINE OF CLOSED DOOR
UNLESS OTHERWISE INDICATED
4. PROVIDE CLEAR SILICONE SEALANT AT PERIMETER OF PLUMBING FLOOR DRAINS, CLEAN
OUTS, ETC IN RESILIENT AND CERAMIC TILE FLOORS
5. PROVIDE SEALANT TO HORIZONTAL AND VERTICAL INTERIOR CERAMIC TILE CORNERS,
COLOR TO MATCH GROUT COLOR
6. PROVIDE SEALANT AT JOINT BETWEEN COUNTER TOP, BACK OR SIDE SPLASH AND WALLS
7. PROVIDE CLEAR SILICONE SEALANT AT THE BASE OF DOOR FRAME TO RESILIENT AND CT
FLOORING, TYP. SEE PLANS AND ROOM FINISH SCHEDULE FOR FLOOR FINISH LOCATIONS
8. HOLLOW METAL DOORS AND FRAMES TO BE PAINTED AS NOTED IN THE FINISH SCHEDULE
9. WOOD: PRE-FINISHED TO MATCH BUILDING STANDARD, REFER TO SPECIFICATION
10. CEILING HEIGHTS AND MATERIALS/FINISHES CALLED OUT IN ROOM FINISH SCHEDULE ARE
FOR ENTIRE CEILING OR MAJORITY OF THAT ROOM, UNLESS OTHERWISE INDICATED. SEE
REFLECTED CEILING PLAN FOR CHANGES IN CEILING MATERIAL AND CEILING HEIGHT. PAINT
ALL SURFACES OF SOFFIT SAME COLOR AS INDICATED
11. COLOR SELECTIONS ARE BASED ON USE OF PRODUCTS INDICATED IN THE PROJECT
MANUAL SPECIFICATION. IF MANUFACTURERS OTHER THAN THOSE INDICATED ARE USED,
ARCHITECT MAY REVISE COLOR SELECTIONS OF OTHER FINISHES TO ENSURE PROPER
COORDINATION
12. PAINT ALL FIRE EXTINGUISHER CABINETS TO MATCH COLOR OF THE ADJACENT WALLS
13. CEILING HEIGHTS ARE MEASURED FROM FINISH FLOOR
14. FOR FLOOR FINISH MATERIALS AND PATTERN, SEE FINISH PLAN
15. SEE INTERIOR ELEVATIONS FOR MORE FINISH INFO
FINISH PLAN GENERAL NOTES
ACT ACOUSTICAL CEILING TILE
CPT MODULAR CARPET TILE
CT CERAMIC TILE
EPY EPOXY FLOORING
GWB (SC) GYPSUM WALLBACK SYSTEMS (SPECIAL COATING)
LVT LUXURY VINYL TILE
P PAINT
PT PORCELAIN TILE (FLOOR AND BASE)
RB RESILIENT BASE
RES RESINOUS EPOXY FLOORING
RES-W RESINOUS/EPOXY WALL/CEILING
RF RUBBER FLOORING
RWC RIGID VINYL WALL COVERING
S SOLID SURFACE
SC SPECIAL COATING
SD STATIC DISSIPATIVE
SP SPECIAL FACED
VWC VINYL WALL COVERING
WP WALL PROTECTION
WSF WELDED SEAM SHEET FLOORING (HEAT WELDED WITH ROD)
ROOM FINISH LEGEND &
ABBREVIATIONS
MATERIAL INSTALL
DIRECTION
KEYNOTECORNER GUARD
WALL PROTECTION
AS INDICATED
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
CG AF10
WALLCOVERING AS
INDICATED
CPT-1
LVT-2
LVT-1
LVT-3
FLOOR FINISH LEGEND
SD-1
RES-2RES-1
PT-2
CPT-2
CPT-3
PT-1
WSF-1
FINISH PLAN KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
FN1 INSTALL HANDRAIL
FN2 NOT USED
FN3 NOT USED
FN4 NOT USED
FN5 INSTALL TS-5 AT TRANSITION FROM NEW FINISH FLOOR TO EXISTING
FLOORING OUTSIDE THE LIMITS OF CONSTRUCTION.
FN6
FN7
FN8
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
C U s e rs
\P u b lic \D o c u m e n ts \R e v it P ro je c ts
\1
-R g b a rb a ri a e -m n .c o m
.r v t
/8
/2
:2
:5
A
M
AF111-B45
FIRST LEVEL FINISH PLAN -
BUILDING 45
CONSTRUCT
PROSTHETICS FACILITY
HAMPTON, VA.
590-210
09/02/2022 MP MP16149
3/16" = 1'-0"1 FIRST LEVEL FINISH PLAN
Revisions: Date: 09/12/2022
I hereby certify that this plan, specification, or report was prepared by me, or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name: Steve Schlotthauer
224-45
SHOE
MODIFICATION
STORAGE 223-45
PARTS
STORAGE
222-45
ELEVATOR
EQUIP
S202-45
STAIR 2
225-45
WHEELCHAIR
PARTS
STORAGE
226-45
DME ACTIVE
STORAGE
220-45
MECHANICAL
221-45
TELECOM
228-45
PROSTHETICS/
ORTHOTICS
MAINTENANCE
227-45
ELECTRICAL
208-45
STAFF
TOILET
207-45
COPY/
WORK/MAILING
206-45
PROSTHETICS
REP OFFICE
205-45
ASSIST
CHIEF
OFFICE 204-45
CHIEF
OFFICE
203-45
STAFF
LOUNGE
203A-45
LOCKERS
S200-45
STAIR 1
202-45
CONFERENCE
201-45
OPEN
OFFICEOPEN TO
BELOW
FLAT ROOF BELOW
C200-45
CORRIDOR
C200-45
CORRIDOR
VWC-2 VWC-2
CG1
CG1 CG1CG1CG1
CG1CG1
CG1
CG1
CG1
DEDUCT ALTERNATE 3
CPT-1
LVT-2
LVT-1
LVT-3
FLOOR FINISH LEGEND
SD-1
RES-2RES-1
PT-2
CPT-2
CPT-3
PT-1
WSF-1
1. FIELD FINISH VENTS, GRILLES, ACCESS PANELS, PLUG STRIP, BASEBOARD RADIATION
ENCLOSURES, ELECTRICAL PANEL BOARDS (IN FINISHED SPACES AS THEY OCCUR) TO MATCH
SURFACE ON WHICH THEY OCCUR UNLESS OTHERWISE INDICATED. EXCEPTION: ITEMS WITH
FACTORY WHITE FINISH, OCCURRING ON WHITE ACT OR WHITE GYPSUM BOARD CEILING
SHALL NOT BE PAINTED. STAINLESS STEEL ITEMS SHALL NOT BE PAINTED
2. FIELD VERIFY ALL NEW CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO
INSTALLATION
3. LOCATE CHANGES IN FLOOR FINISH MATERIAL UNDER CENTERLINE OF CLOSED DOOR
UNLESS OTHERWISE INDICATED
4. PROVIDE CLEAR SILICONE SEALANT AT PERIMETER OF PLUMBING FLOOR DRAINS, CLEAN
OUTS, ETC IN RESILIENT AND CERAMIC TILE FLOORS
5. PROVIDE SEALANT TO HORIZONTAL AND VERTICAL INTERIOR CERAMIC TILE CORNERS,
COLOR TO MATCH GROUT COLOR
6. PROVIDE SEALANT AT JOINT BETWEEN COUNTER TOP, BACK OR SIDE SPLASH AND WALLS
7. PROVIDE CLEAR SILICONE SEALANT AT THE BASE OF DOOR FRAME TO RESILIENT AND CT
FLOORING, TYP. SEE PLANS AND ROOM FINISH SCHEDULE FOR FLOOR FINISH LOCATIONS
8. HOLLOW METAL DOORS AND FRAMES TO BE PAINTED AS NOTED IN THE FINISH SCHEDULE
9. WOOD: PRE-FINISHED TO MATCH BUILDING STANDARD, REFER TO SPECIFICATION
10. CEILING HEIGHTS AND MATERIALS/FINISHES CALLED OUT IN ROOM FINISH SCHEDULE ARE
FOR ENTIRE CEILING OR MAJORITY OF THAT ROOM, UNLESS OTHERWISE INDICATED. SEE
REFLECTED CEILING PLAN FOR CHANGES IN CEILING MATERIAL AND CEILING HEIGHT. PAINT
ALL SURFACES OF SOFFIT SAME COLOR AS INDICATED
11. COLOR SELECTIONS ARE BASED ON USE OF PRODUCTS INDICATED IN THE PROJECT
MANUAL SPECIFICATION. IF MANUFACTURERS OTHER THAN THOSE INDICATED ARE USED,
ARCHITECT MAY REVISE COLOR SELECTIONS OF OTHER FINISHES TO ENSURE PROPER
COORDINATION
12. PAINT ALL FIRE EXTINGUISHER CABINETS TO MATCH COLOR OF THE ADJACENT WALLS
13. CEILING HEIGHTS ARE MEASURED FROM FINISH FLOOR
14. FOR FLOOR FINISH MATERIALS AND PATTERN, SEE FINISH PLAN
15. SEE INTERIOR ELEVATIONS FOR MORE FINISH INFO
FINISH PLAN GENERAL NOTES
ACT ACOUSTICAL CEILING TILE
CPT MODULAR CARPET TILE
CT CERAMIC TILE
EPY EPOXY FLOORING
GWB (SC) GYPSUM WALLBACK SYSTEMS (SPECIAL COATING)
LVT LUXURY VINYL TILE
P PAINT
PT PORCELAIN TILE (FLOOR AND BASE)
RB RESILIENT BASE
RES RESINOUS EPOXY FLOORING
RES-W RESINOUS/EPOXY WALL/CEILING
RF RUBBER FLOORING
RWC RIGID VINYL WALL COVERING
S SOLID SURFACE
SC SPECIAL COATING
SD STATIC DISSIPATIVE
SP SPECIAL FACED
VWC VINYL WALL COVERING
WP WALL PROTECTION
WSF WELDED SEAM SHEET FLOORING (HEAT WELDED WITH ROD)
ROOM FINISH LEGEND &
ABBREVIATIONS
MATERIAL INSTALL
DIRECTION
KEYNOTECORNER GUARD
WALL PROTECTION
AS INDICATED
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
CG AF10
WALLCOVERING AS
INDICATED
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
C U s e rs
\P u b lic \D o c u m e n ts \R e v it P ro je c ts
\1
-R g b a rb a ri a e -m n .c o m
.r v t
/8
/2
:2
:0
A
M
AF121-B45
SECOND LEVEL FINISH PLAN -
BUILDING 45
CONSTRUCT
PROSTHETICS FACILITY
HAMPTON, VA.
590-210
09/02/2022 MP MP16149
3/16" = 1'-0"1 SECOND LEVEL FINISH PLAN
Revisions: Date: 09/12/2022
I hereby certify that this plan, specification, or report was prepared by me, or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name: Steve Schlotthauer
LIM
IT
S
OF
C
ON
ST
RU
CT
IO
N
LIM
IT
S
OF
C
ON
ST
RU
CT
IO
N
LIMITS OF CONSTRUCTION
B246-110
ET
WORKSHOP
B247-110
TECH
OFFICE
B245-110
TECH
OFFICE
B243-110
BIOMED
PARTS
B244-110
HAC
B242-110
BIOMED C2B-5-110
CORRIDOR
C2B-1-110
CORRIDOR
B227-110
WORKSTATION
B216-110
TOILET
B227A-110
BREAK
B229-110
OFFICE
B227B-110
FILES
C2B-4-110
CORRIDOR
B214-110
TELECOM
B226-110
COPY
B228-110
OFFICE
B230-110
OFFICE
B230A-110
STORAGE
B232-110
OFFICE
B234-110
OFFICE
B236-110
OFFICE
B238-110
CONFERENCEB239-110
WORKSTATION
B235-110
WORKSTATION
B231-110
WORKSTATION
S2B-5-110
STAIR
B212-110
ELEC
S2B-2-110
STAIR-2
B219
WOMEN'S
TOILET
B22
STORAGEB223
OFFICE
B225
STORAGE
B224
SHARED
OFFICE
B220
BIO
ENGINEERING
E2B-10
ELEVATOR
B209A
CHASE B209
STORAGE
E2B-11 Room
C2B-10
CORRIDOR
LIMITS OF CONSTRUCTIONLIMITS OF CONSTRUCTION
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CG1
CPT-1
LVT-2
LVT-1
LVT-3
FLOOR FINISH LEGEND
SD-1
RES-2RES-1
PT-2
CPT-2
CPT-3
PT-1
WSF-1
FINISH PLAN KEYED NOTES
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
FN1 INSTALL HANDRAIL
FN2 NOT USED
FN3 NOT USED
FN4 NOT USED
FN5 INSTALL TS-5 AT TRANSITION FROM NEW FINISH FLOOR TO EXISTING
FLOORING OUTSIDE THE LIMITS OF CONSTRUCTION.
FN6
FN7
FN8
ACT ACOUSTICAL CEILING TILE
CPT MODULAR CARPET TILE
CT CERAMIC TILE
EPY EPOXY FLOORING
GWB (SC) GYPSUM WALLBACK SYSTEMS (SPECIAL COATING)
LVT LUXURY VINYL TILE
P PAINT
PT PORCELAIN TILE (FLOOR AND BASE)
RB RESILIENT BASE
RES RESINOUS EPOXY FLOORING
RES-W RESINOUS/EPOXY WALL/CEILING
RF RUBBER FLOORING
RWC RIGID VINYL WALL COVERING
S SOLID SURFACE
SC SPECIAL COATING
SD STATIC DISSIPATIVE
SP SPECIAL FACED
VWC VINYL WALL COVERING
WP WALL PROTECTION
WSF WELDED SEAM SHEET FLOORING (HEAT WELDED WITH ROD)
ROOM FINISH LEGEND &
ABBREVIATIONS
MATERIAL INSTALL
DIRECTION
KEYNOTECORNER GUARD
WALL PROTECTION
AS INDICATED
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
CG AF10
WALLCOVERING AS
INDICATED
1. FIELD FINISH VENTS, GRILLES, ACCESS PANELS, PLUG STRIP, BASEBOARD RADIATION
ENCLOSURES, ELECTRICAL PANEL BOARDS (IN FINISHED SPACES AS THEY OCCUR) TO MATCH
SURFACE ON WHICH THEY OCCUR UNLESS OTHERWISE INDICATED. EXCEPTION: ITEMS WITH
FACTORY WHITE FINISH, OCCURRING ON WHITE ACT OR WHITE GYPSUM BOARD CEILING
SHALL NOT BE PAINTED. STAINLESS STEEL ITEMS SHALL NOT BE PAINTED
2. FIELD VERIFY ALL NEW CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO
INSTALLATION
3. LOCATE CHANGES IN FLOOR FINISH MATERIAL UNDER CENTERLINE OF CLOSED DOOR
UNLESS OTHERWISE INDICATED
4. PROVIDE CLEAR SILICONE SEALANT AT PERIMETER OF PLUMBING FLOOR DRAINS, CLEAN
OUTS, ETC IN RESILIENT AND CERAMIC TILE FLOORS
5. PROVIDE SEALANT TO HORIZONTAL AND VERTICAL INTERIOR CERAMIC TILE CORNERS,
COLOR TO MATCH GROUT COLOR
6. PROVIDE SEALANT AT JOINT BETWEEN COUNTER TOP, BACK OR SIDE SPLASH AND WALLS
7. PROVIDE CLEAR SILICONE SEALANT AT THE BASE OF DOOR FRAME TO RESILIENT AND CT
FLOORING, TYP. SEE PLANS AND ROOM FINISH SCHEDULE FOR FLOOR FINISH LOCATIONS
8. HOLLOW METAL DOORS AND FRAMES TO BE PAINTED AS NOTED IN THE FINISH SCHEDULE
9. WOOD: PRE-FINISHED TO MATCH BUILDING STANDARD, REFER TO SPECIFICATION
10. CEILING HEIGHTS AND MATERIALS/FINISHES CALLED OUT IN ROOM FINISH SCHEDULE ARE
FOR ENTIRE CEILING OR MAJORITY OF THAT ROOM, UNLESS OTHERWISE INDICATED. SEE
REFLECTED CEILING PLAN FOR CHANGES IN CEILING MATERIAL AND CEILING HEIGHT. PAINT
ALL SURFACES OF SOFFIT SAME COLOR AS INDICATED
11. COLOR SELECTIONS ARE BASED ON USE OF PRODUCTS INDICATED IN THE PROJECT
MANUAL SPECIFICATION. IF MANUFACTURERS OTHER THAN THOSE INDICATED ARE USED,
ARCHITECT MAY REVISE COLOR SELECTIONS OF OTHER FINISHES TO ENSURE PROPER
COORDINATION
12. PAINT ALL FIRE EXTINGUISHER CABINETS TO MATCH COLOR OF THE ADJACENT WALLS
13. CEILING HEIGHTS ARE MEASURED FROM FINISH FLOOR
14. FOR FLOOR FINISH MATERIALS AND PATTERN, SEE FINISH PLAN
15. SEE INTERIOR ELEVATIONS FOR MORE FINISH INFO
FINISH PLAN GENERAL NOTES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
C U s e rs
\P u b lic \D o c u m e n ts \R e v it P ro je c ts
\1
-R g b a rb a ri a e -m n .c o m
.r v t
/8
/2
:2
:0
A
M
AF121-B110
SECOND LEVEL FINISH PLAN -
BUILDING 110
CONSTRUCT
PROSTHETICS FACILITY
HAMPTON, VA.
590-210
09/02/2022 MP MP16149
1/8" = 1'-0"1 SECOND LEVEL FLOOR PLAN - BUILDING 110 (DEDUCT ALTERNATE 1)
FN5
Revisions: Date: 09/12/2022
I hereby certify that this plan, specification, or report was prepared by me, or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name: Steve Schlotthauer
1. FIELD FINISH VENTS, GRILLES, ACCESS PANELS, PLUG STRIP, BASEBOARD RADIATION
ENCLOSURES, ELECTRICAL PANEL BOARDS (IN FINISHED SPACES AS THEY OCCUR) TO MATCH
SURFACE ON WHICH THEY OCCUR UNLESS OTHERWISE INDICATED. EXCEPTION: ITEMS WITH
FACTORY WHITE FINISH, OCCURRING ON WHITE ACT OR WHITE GYPSUM BOARD CEILING
SHALL NOT BE PAINTED. STAINLESS STEEL ITEMS SHALL NOT BE PAINTED
2. FIELD VERIFY ALL NEW CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO
INSTALLATION
3. LOCATE CHANGES IN FLOOR FINISH MATERIAL UNDER CENTERLINE OF CLOSED DOOR
UNLESS OTHERWISE INDICATED
4. PROVIDE CLEAR SILICONE SEALANT AT PERIMETER OF PLUMBING FLOOR DRAINS, CLEAN
OUTS, ETC IN RESILIENT AND CERAMIC TILE FLOORS
5. PROVIDE SEALANT TO HORIZONTAL AND VERTICAL INTERIOR CERAMIC TILE CORNERS,
COLOR TO MATCH GROUT COLOR
6. PROVIDE SEALANT AT JOINT BETWEEN COUNTER TOP, BACK OR SIDE SPLASH AND WALLS
7. PROVIDE CLEAR SILICONE SEALANT AT THE BASE OF DOOR FRAME TO RESILIENT AND CT
FLOORING, TYP. SEE PLANS AND ROOM FINISH SCHEDULE FOR FLOOR FINISH LOCATIONS
8. HOLLOW METAL DOORS AND FRAMES TO BE PAINTED AS NOTED IN THE FINISH SCHEDULE
9. WOOD: PRE-FINISHED TO MATCH BUILDING STANDARD, REFER TO SPECIFICATION
10. CEILING HEIGHTS AND MATERIALS/FINISHES CALLED OUT IN ROOM FINISH SCHEDULE ARE
FOR ENTIRE CEILING OR MAJORITY OF THAT ROOM, UNLESS OTHERWISE INDICATED. SEE
REFLECTED CEILING PLAN FOR CHANGES IN CEILING MATERIAL AND CEILING HEIGHT. PAINT
ALL SURFACES OF SOFFIT SAME COLOR AS INDICATED
11. COLOR SELECTIONS ARE BASED ON USE OF PRODUCTS INDICATED IN THE PROJECT
MANUAL SPECIFICATION. IF MANUFACTURERS OTHER THAN THOSE INDICATED ARE USED,
ARCHITECT MAY REVISE COLOR SELECTIONS OF OTHER FINISHES TO ENSURE PROPER
COORDINATION
12. PAINT ALL FIRE EXTINGUISHER CABINETS TO MATCH COLOR OF THE ADJACENT WALLS
13. CEILING HEIGHTS ARE MEASURED FROM FINISH FLOOR
14. FOR FLOOR FINISH MATERIALS AND PATTERN, SEE FINISH PLAN
15. SEE INTERIOR ELEVATIONS FOR MORE FINISH INFO
FINISH PLAN GENERAL NOTES
ACT ACOUSTICAL CEILING TILE
CPT MODULAR CARPET TILE
CT CERAMIC TILE
EPY EPOXY FLOORING
GWB (SC) GYPSUM WALLBACK SYSTEMS (SPECIAL COATING)
LVT LUXURY VINYL TILE
P PAINT
PT PORCELAIN TILE (FLOOR AND BASE)
RB RESILIENT BASE
RES RESINOUS EPOXY FLOORING
RES-W RESINOUS/EPOXY WALL/CEILING
RF RUBBER FLOORING
RWC RIGID VINYL WALL COVERING
S SOLID SURFACE
SC SPECIAL COATING
SD STATIC DISSIPATIVE
SP SPECIAL FACED
VWC VINYL WALL COVERING
WP WALL PROTECTION
WSF WELDED SEAM SHEET FLOORING (HEAT WELDED WITH ROD)
ROOM FINISH LEGEND &
ABBREVIATIONS
MATERIAL INSTALL
DIRECTION
KEYNOTECORNER GUARD
WALL PROTECTION
AS INDICATED
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
CG AF10
WALLCOVERING AS
INDICATED
3'- 0"
HANDRAIL
WP-1
RB-2
2'- 7"
TR-1
EQ EQ
DR (WHERE APPLICABLE)
RESIL FLG AS SPECIFIED
TRANSITION STRIP, TS-2
CPT AS
SPECIFIED
CONC SLAB
EQ EQ
DR (WHERE APPLICABLE)
CERAMIC TILE AS SPECIFIED
TRANSITION STRIP, TS-1
RESILIENT
FLG AS
SPECIFIED
CONC SLAB
EQ EQ
DR (WHERE APPLICABLE)
POURED EPOXY FLG - RES-2
TRANSITION STRIP, TS-4
CONC SLAB
DOOR
RESIL FLG AS
SPECIFIED
EQ EQ
DR (WHERE APPLICABLE)
WSF FLG AS
SPECIFIED
HEAT WELD FL MATL AS
REQ/D
CONC SLAB
LVT FLG AS
SPECIFIED
CPT TO RESIL FLG
LVT TO CT
RESIL FLG TO POURED EPOXY (RES-2)LVT FLG TO WSF FLG
CL
DOOR
CL
DOOR
CL
DOOR
CL
EQ EQ
DR (WHERE APPLICABLE)
LVT FLG AS
SPECIFIED
HEAT WELD FL MATL AS
REQ/D
CONC SLAB
LVT FLG AS
SPECIFIED
LVT FLG TO LVT FLG
DOOR
CL
EQ EQ
DR (WHERE APPLICABLE)
RESIL FLG AS SPECIFIED
TRANSITION STRIP, TS-5
RES-1 FLG, CONCRETE,
OR EXIST FLG AS
SCHEDULED
CONC SLAB
RESINOUS FLOORING, CONCRETE
OR EXIST FLG TO RESIL FLG
DOOR
CL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
C U s e rs
\P u b lic \D o c u m e n ts \R e v it P ro je c ts
\1
-R g b a rb a ri a e -m n .c o m
.r v t
/8
/2
:2
:0
A
M
AF600
MATERIAL AND ROOM FINISH
SCHEDULE & FINISH DETAILS
CONSTRUCT
PROSTHETICS FACILITY
HAMPTON, VA.
590-210
09/02/2022 MP MP16149
ROOM FINISH SCHEDULE - BLDG 45
NO. NAME FLOOR FINISH BASE FINISH
WALL FINISH
CEILING FINISH REMARKSNORTH EAST SOUTH WEST
100-45 LOBBY LVT-1/LVT-2 RB-2 N/A WD-1 VWC-1/P-1 VWC-1/P-1 ACT-1
101-45 RECEPTION LVT-1 RB-1 P-1 P-1 N/A P-1 GYP BD
102-45 PATIENT TOILET PT-1 PR-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 GYP BD (P-5)
103-45 FITTING / EXAM SOFT GOODS LVT-1 RB-1 VWC-3 P-5 WP-2/P-5 WP-2/P-5 ACT-1
104-45 FITTING / EXAM SOFT GOODS LVT-1 RB-1 VWC-4 P-5 WP-2/P-5 WP-5/P-5 ACT-1
105-45 FITTING / EXAM SOFT GOODS LVT-1 RB-1 WP-2/P-5 P-5 WVC-5 WP-2/P-5 ACT-1
106-45 FITTING / EXAM SOFT GOODS LVT-1 RB-1 VWC-3 P-5 WP-2/P-5 WP-2/P-5 ACT-1
107-45 FITTING / EXAM SOFT GOODS LVT-1 RB-1 VWC-4 P-5 WP-2/P-5 WP-2/P-5 ACT-1
108-45 FITTING / EXAM SOFT GOODS LVT-1 RB-1 P-5 VWC-5 WP-2/P-5 WP-2/P-5 ACT-1
109-45 FACIAL/ BODY FITTING STUDIO LVT-1 RB-1 P-4 P-4 P-1 P-1 ACT-1
110-45 HAC PT-2 CT-1 CT-1/P-1 CT-1/P-1 CT-1/P-1 CT-1/P-1 ACT-1
111-45 STAFF TOILET PT-1 PR-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 GYP BD (P-5)
112-45 SOILED HOLDING WSF-1 WSF-1 RWC-1/SC-1 RWC-1/SC-1 RWC-1/SC-1 RWC-1/SC-1 ACT-1
113-45 DYNAMIC ALIGNMENT LVT-1 RB-1 P-1 P-2 P-2 P-1 ACT-1
114-45 CAST LVT-1 RB-1 P-1 P-3 P-3 P-1 ACT-1
115-45 EQUIPMENT STORAGE LVT-3 RB-1 P-3 P-3 P-3 P-3 ACT-1
117-45 FITTING / EXAM CUSTOM FAB LVT-1 RB-1 WP-2/P-5 P-5 VWC-3 WP-2/P-5 ACT-1
118-45 PATIENT / PUBLIC TOILET PT-1 PR-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 GYP BD (P-5) 119-45 PATIENT / PUBLIC TOILET PT-1 PR-3 PT-3/P-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 GYP BD (P-5)
120-45 TEAM EVALUATION CPT-1 RB-1 P-4 P-4 P-1 P-1 ACT-1
122-45 STAFF TOILET PT-1 PR-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 GYP BD (P-5)
123-45 OPEN OFFICE CPT-1 RB-1 P-1 N/A P-1 P-1 ACT-1
124-45 ELECTRICAL RES-1 RB-1 P-3 P-3 P-3 P-3 EXPOSED
125-45 MECHANICAL FIRE/H20 RES-1 RB-1 P-3 P-3 P-3 P-3 EXPOSED
126-45 ORTHO SUPERVISOR OFFICE CPT-1 RB-1 P-4/P-1 P-4/P-1 P-4/P-1 P-4/P-1 ACT-1 P-4 TO 8'8", P-1 ABOVE
130-45 PROSTHETICS LAB LVT-3 RB-1 P-5 P-3 P-5 P-5 ACT-1 SEE FINISH PLAN
130A-45 LAB RESTORATION LVT-3 RB-1 P-3 P-5 P-5 P-5 ACT-1 SEE FINISH PLAN
130B-45 LAB DUST ROOM LVT-3 RB-1 P-8 P-8 P-8 P-8 ACT-1
130C-45 PROSTHETICS/ ORTHOTICS FUME LVT-3 RB-1 P-8 P-8 P-8 P-8 ACT-1
130D-45 CAD/ CAM LVT-3 RB-1 P-8 P-8 P-8 P-8 ACT-1
130E-45 TRASH LVT-3 RB-1 RWC-1/P-5 RWC-1/P-5 RWC-1/P-5 RWC-1/P-5 ACT-1
150-45 ELECTRICAL RES-1 RB-1 P-8 P-8 P-8 P-8 EXPOSED
151-45 TELECOM SD-1 RB-1 P-5 FP-1 FP-1 FP-1 EXPOSED
201-45 OPEN OFFICE CPT-1 RB-1 P-1 N/A P-1 P-1 ACT-1
202-45 CONFERENCE CPT-1 RB-1 P-4 P-1 P-1 P-4 ACT-1
203-45 STAFF LOUNGE LVT-2 RB-1 P-2 P-2 P-4 P-4 ACT-1
203A-45 LOCKERS LVT-2 RB-1 P-1 P-1 P-1 P-1 ACT-1
204-45 CHIEF OFFICE CPT-1 RB-1 P-4/P-1 P-4/P-1 P-4/P-1 P-4/P-1 ACT-1
205-45 ASSIST CHIEF OFFICE CPT-1 RB-1 P-2/P-1 P-2/P-1 P-2/P-1 P-2/P-1 ACT-1
206-45 PROSTHETICS REP OFFICE CPT-1 RB-1 P-3/P-1 P-3/P-1 P-3/P-1 P-3/P-1 ACT-1
207-45 COPY/ WORK/MAILING LVT-2 RB-1 P-1 P-1 P-1 P-1 ACT-1
208-45 STAFF TOILET LVT-2 PT-1 PR-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 GYP BD (P-5)
220-45 MECHANICAL RES-2 RES-2 P-5 P-5 P-5 P-5 EXPOSED DEDUCT ALTERNATE 3
221-45 TELECOM SD-1 RB-1 FP-1 FP-1 FP-1 P-5 EXPOSED
222-45 ELEVATOR EQUIP LVT-3 RB-1 P-5 P-5 P-5 P-5 EXPOSED
223-45 PARTS STORAGE LVT-3 RB-1 P-5 P-5 P-5 P-5 ACT-1
224-45 SHOE MODIFICATION STORAGE LVT-3 RB-1 P-5 P-5 P-5 P-5 ACT-1
225-45 WHEELCHAIR PARTS STORAGE LVT-3 RB-1 P-5 P-5 P-5 P-5 ACT-1
226-45 DME ACTIVE STORAGE LVT-3 RB-1 P-5 P-5 P-5 P-5 ACT-1
227-45 ELECTRICAL RES-1 RB-1 P-5 P-5 P-5 P-5 EXPOSED
228-45 PROSTHETICS/ ORTHOTICS MAINTENANCE LVT-3 LVT-3 P-5 P-5 P-5 P-5 ACT-1
C100-45 CORRIDOR LVT-1/LVT-2 RB-2 WP-1/P-1 WP-1/P-1 WP-1/P-1 WP-1/P-1 ACT-1
C101-45 CORRIDOR CPT-2 RB-1 RWC-1/P-1 RWC-1/P-1 RWC-1/P-1 RWC-1/P-1 ACT-1
C102-45 CORRIDOR LVT-1/LVT-2 RB-1 WP-2/P-1 WP-2/P-1 WP-2/P-1 WP-2/P-1/VWC-2 ACT-1
C103-45 CORRIDOR LVT-2 RB-1 P-1 VWC-2/P-1 P-1 P-1 ACT-1
C200-45 CORRIDOR LVT-1 RB-1 P-1 P-1/WVC-2 P-1 P-1 ACT-1
S100-45 STAIR 1 N/A RB-1 P-8 P-8 P-8 P-8 EXPOSED
S102-45 STAIR 2 N/A RB-1 P-8 P-8 P-8 P-8 EXPOSED
S200-45 STAIR 1 N/A RB-1 P-8 P-8 P-8 P-8 EXPOSED
S202-45 STAIR 2 N/A RB-1 P-8 P-8 P-8 P-8 EXPOSED
ROOM FINISH SCHEDULE - BLDG 110
NO. NAME FLOOR FINISH BASE FINISH
WALL FINISH
CEILING FINISH REMARKSNORTH EAST SOUTH WEST
B226-110 COPY LVT-3 RB-1 P-1 P-1 P-1 P-1 ACT-1
B227-110 WORKSTATION CPT-3 RB-1 P-4 P-4 P-4 P-4 ACT-1
B227A-110 BREAK LVT-3 RB-1 P-4 P-1 P-1 P-1 ACT-1
B227B-110 FILES LVT-3 RB-1 P-1 P-1 P-1 P-1 ACT-1
B228-110 OFFICE CPT-3 RB-1 P-1 P-1 P-1 P-1 ACT-1
B229-110 OFFICE CPT-3 RB-1 P-1 P-1 P-1 P-1 ACT-1
B230-110 OFFICE CPT-3 RB-1 P-1 P-1 P-1 P-1 ACT-1
B230A-110 STORAGE LVT-3 RB-1 P-3 P-3 P-3 P-3 ACT-1
B231-110 WORKSTATION CPT-3 RB-1 P-4 P-1 P-1 P-1 ACT-1
B232-110 OFFICE CPT-3 RB-1 P-1 P-1 P-1 P-4 ACT-1
B234-110 OFFICE CPT-3 RB-1 P-1 P-1 P-1 P-2 ACT-1
B235-110 WORKSTATION CPT-3 RB-1 P-2 P-1 P-1 P-1 ACT-1
B236-110 OFFICE CPT-3 RB-1 P-1 P-1 P-1 P-4 ACT-1
B238-110 CONFERENCE CPT-3 RB-1 P-1 P-4 P-1 P-4 ACT-1
B239-110 WORKSTATION CPT-3 RB-1 P-4 P-1 P-1 P-1 ACT-1
B242-110 BIOMED LVT-3 RB-1…