Construction Document Section 4.pdf

PDF 18 MB Posted

Attached to
Y1DA--590-210 Construct Prosthetics Facility (VA-23-00044335) Federal contract opportunity
Solicitation number
36C77623R0166_1
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document provides details on a federal solicitation for construction services. The solicitation number 36C77623R0166_1 was issued by the Department of Veterans Affairs Technology Acquisition Center Austin to construct a Prosthetics Facility at an estimated total cost between $10-25 million. Responses are due by April 15th, 2023 with award anticipated by June 30th, 2023. The opportunity is set aside for Service-Disabled Veteran-Owned Small Businesses. The selected contractor will be responsible for all aspects of building construction in accordance with the specifications provided in the 18MB Construction Document Section 4.pdf file.

View the file

Other files for this federal contract opportunity

Other files attached to Y1DA--590-210 Construct Prosthetics Facility (VA-23-00044335), newest first.
File Type Posted
Amendment 0008 Attachment 1 - Hampton VA RFIs All.docx DOCX document
36C77623R0166 0008.docx DOCX document
Amendment 0008 Attachment 3 - 081113 Hollow Metal Doors and Frames.pdf PDF
Amendment 0008 Attachment 2 - 329000.pdf PDF
36C77623R0166 0007.docx DOCX document
36C77623R0166 0006.docx DOCX document
Amendment 0006 Attachment 3 - 087113-11 LE Power Assist Door Operators.pdf PDF
Amendment 0006 Attachment 4 - 019100 General Commissioning Rev 1.pdf PDF
Amendment 0006 Attachment 5 - 000110 TOC Rev 1.pdf PDF
Amendment 0006 Attachment 1 - Hampton VA RFIs 1-97.docx DOCX document
Amendment 0006 Attachment 2 - 117300 ceiling mounted patient lift system.pdf PDF
36C77623R0166 0005.docx DOCX document
36C77623R0166 0004.docx DOCX document
S06 - 36C77623R0166 0003.docx DOCX document
36C77623R0166 0002.docx DOCX document
wage rates.pdf PDF
36C77623R0166-0001.docx DOCX document
36C77623R0166 0001.docx DOCX document
S04 - Site Visit Sign-in Sheet Completed.pdf PDF
Construction Documents Section 2.pdf PDF
Bid Documents Part 2.pdf PDF
Construction Documents Section 1.pdf PDF
Bid Documents Part 6.pdf PDF
Bid Documents Part 4.pdf PDF
Wage Determination.pdf PDF
Construction Documents Section 3.pdf PDF
Construction Document Section 5.pdf PDF
Bid Documents Part 1.pdf PDF
Bid Documents Part 7.pdf PDF
SPEC VOL I - A.pdf PDF
S02 - RFP - 36C77623R0166_1.docx DOCX document
Hampton VAMC Site Plan.pdf PDF
Site Visit Instructions.docx DOCX document
Bid Documents Part 5.pdf PDF
Bid Documents Part 3.pdf PDF
SPEC VOL I - B.pdf PDF
SPEC VOL II -.pdf PDF
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NO SUBSCRIPT

EXTEND ENTIRE

PARTITION TO

UNDERSIDE OF

STRUCTURE

FLOOR

CEILING

BOTTOM

OF FLOOR

OR DECK

(D) SUBSCRIPT

EXTEND STUDS TO

DECK, EXTEND

GYPSUM BOARD TO

6" ABOVE HIGHEST

ADJACENT CEILING

6"

(C) SUBSCRIPT

EXTEND ENTIRE

PARTITION TO 6"

ABOVE HIGHEST

ADJACENT

CEILING

6"

(U) SUBSCRIPT

EXTEND ENTIRE

PARTITION TO

UNDERSIDE OF

CEILING

(X'-X") SUBSCRIPT

INDICATES

FINISHED

PARTITION HEIGHT

IN

S

UB

SC

RI

PT

HE

IG

HT

A

S

IN

DI

CA

TE

D

GENERAL NOTES:

1. FOR PARTITIONS WITH UNEQUAL LAYERS OF GYPSUM BOARD ON EACH SIDE, THE SIDE OF THE PARTITION

WITH THE TAG INDICATES WHERE THE EXTRA LAYER(S) OF GYPSUM BOARD ARE TO BE INSTALLED. REFER

TO PARTITION TYPES FOR MORE INFORMATION

2. DIMENSIONS TO METAL STUD PARTITIONS ARE MEASURED TO FINISH FACE UNLESS NOTED OTHERWISE

3. AT INFILL WITHIN OR EXTENSIONS ONTO EXISTING PARTITIONS, THE PARTITION TAG NOTED IS FOR INTENT

ONLY. FINISHED PARTITION FACES ARE TO ALIGN WITH ADJACENT EXISTING PARTITION FACES

4. SUBSCRIPTS MAY BE USED WITH ANY PARTITION TYPE

3'-0"UCD

A6

XN2 XN3 XP2 XP3

(1 ) LAYER 5/8" GYPSUM

BOARD EACH SIDE

3 5/8" METAL STUD

FRAMING

(1 ) LAYER 5/8" GYPSUM

BOARD EACH SIDE

6" METAL STUD FRAMING

(1 ) LAYER 5/8" GYPSUM

BOARD EACH SIDE

3 5/8" METAL STUD

FRAMING

(1 ) LAYER 5/8" GYPSUM

BOARD EACH SIDE

6" METAL STUD FRAMING

3" SOUND ATTENUATING

INSULATION

3" SOUND ATTENUATING

INSULATION

(1 ) LAYER 5/8" GYPSUM

BOARD

2 1/2" METAL STUD

FRAMING

(1 ) LAYER 5/8" GYPSUM

BOARD

3 5/8" METAL STUD

FRAMING

3" SOUND ATTENUATING

INSULATION

1 1/2" SOUND

ATTENUATING INSULATION

(1 ) LAYER 5/8" GYPSUM

BOARD

2 1/2" METAL STUD

FRAMING

(1 ) LAYER 5/8" GYPSUM

BOARD

3 5/8" METAL STUD

FRAMING

STC 49 STC 49STC 46 STC 46

4 7/8" 7 1/4" 4 7/8" 7 1/4"

4 1/4"3 1/8"4 1/4"3 1/8"

MA8

7 5/8"

8" CMU

STC 44-49

A3 B3 B6B3bs

(1 ) LAYER 5/8" GYPSUM

BOARD EACH SIDE

3 5/8" METAL STUD

FRAMING

3" SOUND ATTENUATING

INSULATION

UP TO 1HR FIRE & SMOKE RATING

UL DESIGN U419

STC 49

4 7/8"

B6bs

(1 ) LAYER 5/8" GYPSUM

BOARD EACH SIDE

6" METAL STUD FRAMING

3" SOUND ATTENUATING

INSULATION

UP TO 1HR FIRE & SMOKE RATING

UL DESIGN U419

STC 49

7 1/4"

XN1

(1 ) LAYER 5/8" GYPSUM

BOARD

1 5/8" METAL STUD

FRAMING

2 1/4"

XN6

(1 ) LAYER 5/8" GYPSUM

BOARD

6" METAL STUD FRAMING

6 5/8"

1iH6b

6 1/2"

(1 ) LAYER 5/8" GYPSUM

BOARD

6" COLD FORMED

METAL CH STUD 18GA

@ 16" OC

(1) LAYER OF 1" FIRE

RATED SHAFT LINER PANEL

UP TO 1 HR FR

UL415

STC 40-44

3" SOUND

ATTENUATING

INSULATION

XP3a

(1 ) LAYER 5/8" GYPSUM

BOARD

3 5/8" METAL STUD

FRAMING

3" SOUND ATTENUATING

INSULATION

4 1/4" SMOKE TIGHT

B3a

(1 ) LAYER 5/8" GYPSUM

BOARD EACH SIDE

3 5/8" METAL STUD

FRAMING

3" SOUND ATTENUATING

INSULATION

SMOKE RATING

STC 49

4 7/8"

1iMA12

11 5/8"

12" CMU

STC 48-53

XN10

(1 ) LAYER 5/8" GYPSUM

BOARD

10" COLD FORMED METAL

STUD FRAMING - SEE

STRUCTURAL

10 5/8"

PARTITION GENERAL NOTES:

1. SEE LIFE SAFETY PLANS FOR REQUIRED PARTITION FIRE RATINGS.

2. GYPSUM BOARD AND METAL STUDS USED IN FIRE RATED SEPARATION PARTITIONS SHALL

EXTEND FROM FLOOR TO UNDERSIDE OF STRUCTURE, UNLESS NOTED OTHERWISE.

3. WHERE SMOKE PARTITIONS ARE REQUIRED BY LIFE SAFETY PLANS, THE FOLLOWING APPLIES

TO ALL NON-ACOUSTICAL TYPE SMOKE PARTITIONS: EXTEND GYPSUM BOARD ON CORRIDOR

SIDE TO STRUCTURE ABOVE. SEAL TOP AND BOTTOM OF PARTITION AND ALL PENETRATIONS

THROUGH PARTITION ON CORRIDOR SIDE WITH A SMOKE SEALANT HAVING A MINIMUM WARM

SMOKE TEMPERATURE OF 400 DEGREES FAHRENHEIT. ALL SEALS MUST HAVE PRE-APPROVAL

OF CODE OFFICIAL. ROOM SIDE GYPSUM BOARD CAN EXTEND TO 6" ABOVE FINISHED CEILING.

4. CONTRACTORS TO VERIFY CONDITIONS ABOVE CEILING AT EXISTING PARTITIONS IDENTIFIED

WITH FIRE/SMOKE PARTITION SYMBOLS. REPAIR CONDITIONS THAT DO NOT MEET

REQUIREMENTS OF THE INDICATED FIRE/SMOKE RATING SHOWN, SUCH AS BUT NOT LIMITED

TO OPENINGS IN PARTITIONS, GAPS AROUND DUCTWORK, PIPES AND CONDUIT, MISSING

SMOKE DAMPERS, ETC

5. DIMENSIONS TO METAL STUD PARTITION ARE MEASURED TO FINISH FACE OF PARTITION

UNLESS NOTED OTHERWISE

6. THE DIMENSION SHOWING THE LOCATION OF A DOOR FRAME IN GYPSUM BOARD WALLS IS TO

THE INSIDE OF THE DOOR FRAME (DOOR OPENING). PROVIDE 4" TYPICAL DIMENSION IF NO

DIMENSION IS SHOWN.

7. SOUND ATTENUATING INSULATION MEANS GLASS FIBER OR MINERAL WOOL BATTS OR

BLANKETS BEARING THE UL LABEL FOR FIRE RESISTANCE. VERIFY TYPE AND DENSITY (PCF)

WITH FIRE TEST NUMBER SHOWN ON PARTITION TYPE.

8. FOR PARTITION HEIGHTS SEE PARTITION TAG LEGEND AND TAG SUBSCRIPTS ON PLANS.

9. ALL FURRING TO BE PARTITION TYPE XP3, ALL PARTITIONS ARE TO BE PARTITION TYPE B3, UNLESS NOTED OTHERWISE.

10. FOR PARTITION TYPES WITH GYPSUM BOARD ON ONE SIDE ONLY, INSTALL GYPSUM BOARD

ON ROOM SIDE, UNLESS NOTED OR DETAILED OTHERWISE. FOR SHAFTWALL PARTITION

TYPES, INSTALL LINER PANEL ON NON-ACCESSIBLE SIDE, UNLESS NOTED OR DETAILED

OTHERWISE.

11. PROVIDE 1/2" DEFLECTION SPACE AT THE TOP OF STUDS AT ALL PARTITIONS EXTENDING TO

STRUCTURE, UNLESS NOTED OTHERWISE.

12. WHEN GYPSUM BOARD PARTITIONS ARE LOCATED BELOW STRUCTURE THAT HAS A

VERTICAL DEFLECTION MOVEMENT MORE THAN 1/2", PROVIDE PARTITION HEADS WITH

VERTICAL MOVEMENT CAPABILITY TO MATCH THAT DEGREE OF MOVEMENT. MAINTAIN THE

REQUIRED FIRE RATING OF FIRE RATED PARTITIONS FROM FLOOR TO STRUCTURE ABOVE

WITH FIRE TESTED HEAD CONSTRUCTION.

13. WHEN PARTITION FRAMING RUNS HIGHER THAN 12'-0" ABOVE FINISH FLOOR, BRACE

PARTITION BACK TO STRUCTURE ABOVE WITH METAL STUDS EVERY 4'-0" ON CENTER

MINIMUM.

14. BULKHEAD FRAMING SHALL EXTEND TO UNDERSIDE OF STRUCTURE WITH DIAGONAL STUD

FRAMING BRACES AT 4'-0" ON CENTER (2 BRACES MINIMUM) WITH GYPSUM BOARD EXTENDING

6" ABOVE CEILING MINIMUM, UNLESS NOTED OTHERWISE.

15. GENERAL CONTRACTOR SHALL PROVIDE AND COORDINATE ALL IN-WALL BLOCKING FOR

WALL MOUNTED CASEWORK AND EQUIPMENT SUPPLIED BY THIS CONTRACT, OWNER

FURNISHED OR BY VENDORS. CONTRACTORS OPTION TO PROVIDE 3/4" FIRE TREATED

PLYWOOD OR SHEET METAL BLOCKING FOR WALL MOUNTED EQUIPMENT, CASEWORK, DOOR

STOPS, ACCESSORIES, ETC, UNLESS NOTED OTHERWISE.

16. IN WET AREAS SUCH AS BUT NOT LIMITED TO SHOWER, TUB, GLASS WASHING ROOMS,

SOILED UTILITY ROOMS, JANITOR CLOSETS, COMMERCIAL FOOD PROCESSING ROOMS, ETC,

USE TILE BACKER BOARD BEHIND THE CERAMIC TILE AND EXTEND TO 2'-0" BEYOND ALL SIDES

OF THE PLUMBING FIXTURE. IN DOUBLE LAYER WALLS WHERE THE TILE BACKER BOARD IS

INSTALLED OVER A BASE LAYER OF GYPSUM BOARD, APPLY A WATER BARRIER (BUILDING

WRAP) NOT A VAPOR RETARDER, OVER THE BASE LAYER OF GYPSUM BOARD. IN HIGH

HUMIDITY AREAS SUCH AS SAUNAS, STEAM ROOMS AND SWIMMING POOLS, WHERE WALLS

ARE EXPOSED TO CONSTANT MOISTURE, USE TILE BACKER BOARD BEHIND CERAMIC TILE.

17. IN WET AREAS SUCH AS SOILED UTILITY ROOMS, JANITOR CLOSETS, ETC, USE 5/8" WATER

RESISTANT GYPSUM BOARD OR 5/8" FR WATER RESISTANT GYPSUM BOARD.

18. FOR ALL REMODELING PROJECTS, ALL PARTITIONS NOTED AT INFILLS WITHIN, OR

EXTENSIONS ONTO EXISTING PARTITIONS, ARE NOTED AS SUCH FOR INTENT ONLY. ALL

EXPOSED PARTITION FACES ARE TO ALIGN.

NOTE:

WHERE LIFE SAFETY PLANS SHOW A

PARTITION IS RATED, THE PARTITION

WITH THE HIGHEST RATING WILL BE

CONTINUOUS.

NON-RATED

PARTITION PER LIFE

SAFETY PLAN

1 HOUR RATED PARTITION

PER LIFE SAFETY PLAN

2 HOUR RATED PARTITION

PER LIFE SAFETY PLAN

1 HOUR RATED PARTITION

PER LIFE SAFETY PLAN

SB1 FC1

WALL ASSEMBLY

4" FACEBRICK

2" AIR SPACE

3" RIGID INSULATION

BUILDING MEMBRANE

5/8" GYPSUM SHEATHING

6" STUDS - SEE STRUCTURAL

5/8" GPBD

MASONRY TIE

7 1/4" 8 5/8"

1'-3 7/8"

10 1/4" 5 3/4"

1'-4"

WALL ASSEMBLY

5/16 FIBER CEMENT BOARD

5/8" FIRE TREATED PLYWOOD

AIR SPACE

3" RIGID INSULATION

BUILDING MEMBRANE

5/8" GYPSUM SHEATHING

6" STUDS - SEE STRUCTURAL

5/8" GPBD

3/4"

1/4"

1 3 /4"

1/2 " 1/2

2 1/2" 2 5/8"

5 1/8"

SILL PROFILE

9 1

/8"

3 5/8"

CAST STONE BAND PROFILE

2 3 /4"

CAST STONE PARAPET CAP PROFILE

EQ EQ

5" 1"

3/4" 1/4"

1'-11"

SPLIT TAIL ANCHOR BEYOND.

ACOUSTIC PARTITION GENERAL

NOTES:

1. USE ACOUSTICAL SEALANT AT ALL GPBD PARTITION PENETRATIONS AND JOINTS SUCH AS

THE STRUCTURE ABOVE, FLOOR SURFACES AND PARTITIONS CONSTRUCTED OF ANOTHER

MATERIAL, UNLESS NOTED OTHERWISE.

2. ALLOW MINIMUM 1/8" SPACE BETWEEN ELECTRICAL BOX AND GPBD, FILL GAP WITH

ACOUSTICAL SEALANT.

3. BEFORE INSTALLING GPBD PANELS OR SOUND ATTENUATION INSULATION, APPLY MINIMUM

1/16" THICKNESS OF ACOUSTICAL SEALANT OVER KNOCKOUTS OR OTHER SMALL HOLES IN

THE ELECTRICAL BOXES TO INSURE THAT THEY ARE AIR TIGHT. IF A KNOCKOUT IS MISSING, WRAP WITH TAPE AND COVER WITH ACOUSTICAL SEALANT TO AT LEAST 1/8" THICK. INSPECT

BACK SEALING OF BOXES BEFORE THE SOUND ATTENUATION INSULATION AND GPBD

PANELS ARE INSTALLED.

4. WHEN SOUND ATTENUATION INSULATION (SA INS) IS USED, IT MUST NOT CONTACT THE

GPBD MOUNTED ON THE RESILIENT CHANNEL SIDE OF PARTITION AS THE LISTED SOUND

ATTENUATION VALUE WILL BE COMPROMISED.

5. LOCATE OUTLETS IN ALTERNATE STUD CAVITIES AND USE SEPARATE CONDUIT FOR

OUTLETS ON OPPOSITE SIDE OF THE SAME PARTITION.

6. ELECTRICAL BOXES CAN BE RIGIDLY MOUNTED TO STUDS WITH STANDARD MOUNTING

BRACKETS. DO NOT ALLOW BOX, MOUNTING BRACKETS OR CONDUIT TO TOUCH THE

RESILIENT CHANNELS. ELECTRICAL BOXES ARE NOT PERMITTED IN WALLS EXCEEDING A

TWO HOUR FIRE RATING UNLESS WALLS ARE SO TESTED.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C U s e rs

\P u b lic \D o c u m e n ts \R e v it P ro je c ts

\1

-R g b a rb a ri a e -m n .c o m

.r v t

/8

/2

:2

:4

A

M

AE601

WALL & PARTITION TYPES AND

DETAILS

CONSTRUCT

PROSTHETICS FACILITY

HAMPTON, VA.

590-210

09/02/2022 LA GJB16149

TYPES - PARTITION

GUIDELINE - RATED WALL INTERSECTIONS

TYPES - WALL

ARCHITECTURAL PRECAST PROFILES

Revisions: Date: 09/12/2022

I hereby certify that this plan, specification, or report was prepared by me, or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Name: Steve Schlotthauer

Signature:_________________

Date:__________ License# 42138

PANEL PREFIXES

AL- ALUMINUM

CG- COILING GRILLE

CS- COILING SLATS

HM- HOLLOW METAL

OS- OVERHEAD SECTIONAL

RD3- REVOLVING DOOR 3 PANEL

RD4- REVOLVING DOOR 4 PANEL

VL- VERTICAL LIFT

WD- WOOD

AG ALL GLASS

BF BIFOLD

BFG BIFOLD GLASS

D DUTCH

DG DUTCH GLASS

DS DUTCH W/SHELF

F FLUSH

G2 GLASS 2 LIGHT

G3 GLASS 3 LIGHT

GF GLASS FULL

GH GLASS HALF

LF LOUVER FULL

LGH LOUVER GLASS HALF

LH LOUVER HALF

HM-GF

FRAME PREFIXES

0 FRAMED-CASED OPENING

1 DOOR ONLY

2 SIDELIGHT(S) 1 SIDE

3 SIDELIGHT(S) 1 SIDE W/HORIZONTAL

4 SIDELIGHT(S) BOTH SIDES

5 SIDELIGHT(S) BOTH SIDES W/HORIZONTAL

6 DOOR W/TRANSOM

7 DOOR W/TRANSOM W/SIDELIGHT(S) 1 SIDE

8 TRANSOM W/SIDELIGHT(S) 1 SIDE W/HORIZONTAL

9 TRANSOM W/SIDELIGHT(S) BOTH SIDES

10 TRANSOM W/SIDELIGHT(S) BOTH SIDES W/HORIZONTAL

11 FULL WIDTH TRANSOM W/SIDELIGHT(S) 1 SIDE

1X1 1 LIGHT WIDE AND 1 LIGHT HIGH

2X2 2 LIGHTS WIDE AND 2 LIGHTS HIGH

3X3 3 LIGHTS WIDE AND 3 LIGHTS HIGH

(NOTE: OTHER COMBINATIONS POSSIBLE)

OX FIXED PANEL, ACTIVE PANEL

OXO FIXED PANEL, ACTIVE PANEL, FIXED PANEL

OXX FIXED, ACTIVE, ACTIVE

OXXO FIXED, ACTIVE, ACTIVE, FIXED

OXXXXO FIXED, ACTIVE, ACTIVE, ACTIVE, ACTIVE, FIXED

HMS-2

LNV LOUVER NARROW VISION

NV NARROW VISION

NV2 NARROW VISION 2 LIGHT

NV3 NARROW VISION 3 LIGHT

NVC NARROW VISION CENTERED

RP2 RAISED PANEL 2 PANEL

RP4 RAISED PANEL 4 PANEL

RP6 RAISED PANEL 6 PANEL

RP8 RAISED PANEL 8 PANEL

V VISION

W WINDOWS (1 ROW)

WT WINDOWS THROUGHOUT

DOOR PANEL NAMING

DOOR FRAME NAMING NOTE: ACTUAL FRAMES MAY VARY FROM DESCRIPTIONS

BELOW, REFER TO FRAME TYPE ELEVATIONS

NOTE: ACTUAL PANELS MAY VARY FROM DESCRIPTIONS

BELOW, REFER TO PANEL TYPE ELEVATIONS

PANEL SUFFIXES

AL- ALUMINUM

AL-BL- ALUMINUM BORROWED LIGHT

AL-SL- ALUMINUM SLIDING

ALR- ALUMINUM REVOLVING

CW## CURTAINWALL

HMM- HOLLOW METAL MASONRY

HMM-BL- HMM BORROWED LIGHT

HMM-DE- HMM DOUBLE EGRESS

HMS- HOLLOW METAL STUD

HMS-BL- HMS BORROWED LIGHT

HMS-DE- HMS DOUBLE EGRESS

OC- OVERHEAD COILING

OS- OVERHEAD SECTIONAL

VL- VERTICAL LIFT

WD- WOOD

WD-BL- WOOD BORROWED LIGHT

WDP- WOOD POCKET

FRAME SUFFIXES

ISOMETRIC DETAIL

VERTICAL STUDS @ 2' - 0" MAX

W/ GYPSUM BD 1' - 4" W/ GYPSUM LATH &

PLASTER DOUBLE STUDS FOR SUPPORTING CONC

BACKER BOARD

PROVIDE CONTINUOUS BRACING WHEN STUDS

EXCEED 10' - 0" & ARE FINISHED BOTH SIDES

JAMB ANCHOR CLIPS 3 PER SIDE -

COORDINATE W/ HINGE REINFORCEMENT

NOTE 1:

OMIT BRACE WHEN "D" DIMENSION IS LESS THAN 2' - 0"

FOR GYP WALL BD. OR 16" FOR PLASTER PARTITION.

CRIPPLE STUD

DO NOT ANCHOR TO

BEARING STUD

GYP BD PANELS

CONTROL

JOINT

PROVIDE SOUND

DEADENING

WHERE REQ'D.

ISOMETRIC OF CONSTRUCTION JOINT.

SECTION A DETAIL C

JAMB ANCHORS

(FURNISHED WITH FRAME)

DETAIL D

DOUBLE STUDS

JAMB ANCHOR

SHIM AS

REQ'D

METAL

ANCHOR CLIP

METAL DOOR

FRAME

SANITARY STOP

WHERE REQ'D

SEC B

CONTROL JOINT

BOTH SIDES OF

PARTITION

6" M

AX

DETAIL D

SEE DOOR SCHEDULE

VARIES

SHIM AS REQ'D

DETAIL C

VA

RI

ES

EQ

EQEQ

EQ

D

RUNNER

BET.

STUDS

MTL

DOOR

FRAME

A A

1/2" MIN

1/2 " M

IN

SECTION B

STUDWIDTH

FRAME FACE

MINUS 3/16"

3/4 " M

IN

JAMB DEPTH

MINUS 3/16"

FRAME FACE

MINUS 3/16"3/4

" M

IN

1/2" MIN

5/8" MAX

STUDWIDTH

3/4 " M

IN

GYPSUM

CONTROL JOINT

@ DOOR HEADS

FINISHED

FLOOR

HM-F

WD-F

AL-NV

WD-NV

HM-GH

WD-GH

WD-GF

WIDTH

OPENING

OP

EN

IN

G

HE

IG

HT

WIDTH

OPENING

WIDTH

OPENING

WIDTH

OPENING

OP

EN

IN

G

HE

IG

HT

OP

EN

IN

G

HE

IG

HT

OP

EN

IN

G

HE

IG

HT

" M

AX

1'- 0"

6"6"

" M

AX

1'- 0"

6" 6"

1'- 0"

AL-GF

WIDTH

OPENING

OP

EN

IN

G

HE

IG

HT

1'- 0"

6" 6"

1'- 0"

FINISHED

FLOOR

HMS-1 HMM-1

OP

EN

IN

G

HE

IG

HT

WIDTH

OPENING

OP

EN

IN

G

HE

IG

HT

WIDTH

OPENING

AL-7

OP

EN

IN

G

HE

IG

HT

FI

ED

V

ER

IF

Y

'-6

FIED VERIFY

OPENING WIDTH

AL-6

OP

EN

IN

G

HE

IG

HT

FI

ED

V

ER

IF

Y

'-4

R 3'- 0"

WIDTH

OPENING

FIED VERIFY

6'-0"

PREFINISHED

INSULATED & BLAST

RESISTANT PANEL

IG-1

IL-1

1" SURFACE APPLIED

MULLIONS. MITER ENDS OF

MULLIONS WHERE THEY

INTERSECT

7'- 2"

5/

8"

3 3 /8"

SEE FOR MUNTIN DETAIL/5 AE602

VARIES

AS

S

CH

ED

METAL STUDS

GYP BD

HM FRAME

DOOR AS SCHED

2"

METAL RUNNER

NOTE:

1. FOR PARTITION TYPES SEE PLANS

2. SEE AE602 FOR FRAME PROFILE INFORMATION.

VARIES

2"

AS

S

CH

ED

HM FRAME

DOOR AS SCHED

METAL STUDS

GYP BD

NOTE:

1. FOR PARTITION TYPES SEE PLANS

2. SEE AE602 FOR FRAME PROFILE INFORMATION.

1. 5/8" AT 20 MINUTE FIRE RATED FRAMES AND NON-RATED FRAMES, 3/4" AT FIRE RATED FRAMES OF 45

MINUTES AND ABOVE.

2. 5/8" AT 20 MINUTE FIRE RATED FRAMES AND NON-RATED FRAMES, 1" AT FIRE RATED FRAMES OF 45

MINUTES AND ABOVE.

3. FOR FRAMES IN GYP BD PARTITIONS, VERIFY THAT THE FRAME THROAT DEPTH MATCHES THE

PARTITION THICKNESS.

4. 5 3/4" AT MASONRY OR DEEP GYP BD WALL RECESSES WHERE FRAME DOES NOT WRAP THE WALL.

FRAME PROFILE NOTES:

FACE OF WALL

HM FRAME

CORRIDOR

SIDE

A

HEAD

HM FRAME

DOOR

- SEE OPENING

SCHEDULE

JAMBS

C

DOOR OR GLAZING / STOP

(SHOWN) AS

SCHEDULED -SEE

OPENING SCHEDULE

ROOM SIDE

B

SEE NOTE 2

ON

P

LA

N

2"

UN

O

TY

PE

SE

E

FR

AM

E

SE

E

NO

TE

TYPES UNO

SEE GYP BD PTN

SEE NOTE 4

SEE GYP BD PTN

5 3/4" AT MASONRY UNO

TYPES UNO

SEE GYP BD PTN

5 3/4" AT MASONRY UNO

TY

PE

SE

E

FR

AM

E

TYPES UNO

SEE GYP BD PTN

5 3/4" AT MASONRY UNO

TY

PE

SE

E

FR

AM

E

HM FRAME

DOOR

- SEE OPENING

SCHEDULE

3 3 /8"

R 2'-10"

R 2'-2 5/8"

R 1'-

7 5 /8"

R 1'-0 5/8"

R 1'-0 5/8"

30.00°

30.

00°

.00

MITER MUNTINS AT INTERSECTIONS

R 5 5/8"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C U s e rs

\P u b lic \D o c u m e n ts \R e v it P ro je c ts

\1

-R g b a rb a ri a e -m n .c o m

.r v t

/8

/2

:2

:4

A

M

AE602

DOOR SCHEDULE AND

ELEVATIONS

CONSTRUCT

PROSTHETICS FACILITY

HAMPTON, VA.

590-210

09/02/2022 LA GJB16149

OPENING SCHEDULE

ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION

HD

W

G

RO

UP

FI

RE

LA

BE

L (

MI

N)

GA

SK

ET

EL

EC

TR

IC

AL

S

LA

BE

L

COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT

PANEL

TYPE

2ND

PANEL

TYPE

PANEL

GLAZING FRAME TYPE

FRAME

GLAZING

LOBBY 100-45 6'-0" 7'-0" AL-GF AL-GF LG-2 AL-6 IL-1 1.0 Y Y CLOSER, INSULATED, BLAST

RESISTANT

CORRIDOR RECEPTION 101-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 15.0

CORRIDOR PATIENT TOILET 102-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 17.0

CORRIDOR FITTING / EXAM SOFT GOODS 103-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0

CORRIDOR FITTING / EXAM SOFT GOODS 104-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0

CORRIDOR FITTING / EXAM SOFT GOODS 105-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0

CORRIDOR FITTING / EXAM SOFT GOODS 106-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0

CORRIDOR FITTING / EXAM SOFT GOODS 107-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0

CORRIDOR FITTING / EXAM SOFT GOODS 108-45 3'-6" 7'-0" WD-NV MG-1 HMS-1 NONE 19.0

CORRIDOR FACIAL/ BODY FITTING STUDIO 109-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0

CORRIDOR HAC 110-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 12.0

CORRIDOR STAFF TOILET 111-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 16.0

CORRIDOR SOILED HOLDING 112-45 3'-6" 7'-0" WD-NV MG-1 HMS-1 NONE 14.0 Y Y

CORRIDOR DYNAMIC ALIGNMENT 113-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0

CORRIDOR CAST 114-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 19.0

CORRIDOR EQUIPMENT STORAGE 115-45 3'-8" 7'-0" WD-F NONE HMS-1 NONE 6.0 Y Y CLOSER

CORRIDOR FITTING / EXAM SOFT GOODS 116-45 4'-0" 7'-0" WD-F NONE HMS-1 NONE 19.0

CORRIDOR FITTING / EXAM CUSTOM FAB 117-45 4'-0" 7'-0" WD-F NONE HMS-1 NONE 19.0

CORRIDOR PATIENT / PUBLIC TOILET 118-45 3'-8" 7'-0" HM-F NONE HMM-1 NONE 18.0 CLOSER, BLAST RESISTANT CORRIDOR PATIENT / PUBLIC TOILET 119-45 3'-8" 7'-0" HM-F NONE HMM-1 NONE 18.0 CLOSER, BLAST RESISTANT CORRIDOR TEAM EVALUATION 120A-45 4'-0" 7'-0" HM-F NONE HMS-1 NONE 10.0 CLOSER, 14GA VERTICALLY

STIFFENED

CORRIDOR TEAM EVALUATION 120B-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 19.0

CORRIDOR STAFF TOILET 122-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 16.0

CORRIDOR ELECTRICAL 124-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 11.0

CORRIDOR MECHANICAL FIRE/H20 125-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 12.0

CORRIDOR ORTHO SUPERVISOR OFFICE 126-45 3'-0" 7'-0" WD-NV MG-1 HMS-1 NONE 15.0

CORRIDOR PROSTHETICS LAB 130A-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 9.0 CARD READER, CLOSER, GASKET, POWER OPERATOR

LAB DUST ROOM PROSTHETICS LAB 130B-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 20.0

PROSTHETICS/ ORTHOTICS FUME PROSTHETICS LAB 130C-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 20.0

CAD/ CAM PROSTHETICS LAB 130D-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 21.0

CORRIDOR ELECTRICAL 150-45 3'-0" 7'-0" HM-F NONE HMM-1 NONE 13.0 CLOSER, BLAST RESISTANT CORRIDOR TELECOM 151-45 3'-0" 8'-0" HM-F NONE HMS-1 NONE 10.0 45 Y Y Y CARD READER, CLOSER, GASKET, BLAST RESISTANT, 14GA

VERTICALLY STIFFENED

CORRIDOR CONFERENCE 202-45 3'-6" 7'-0" WD-NV MG-1 HMS-1 NONE 21.0

STAFF LOUNGE LOCKERS 203A-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 22.0

CORRIDOR STAFF LOUNGE 203B-45 3'-6" 7'-0" WD-NV MG-1 HMS-1 NONE 22.0

CORRIDOR CHIEF OFFICE 204-45 3'-0" 7'-0" WD-NV MG-1 HMS-1 NONE 15.0

CORRIDOR ASSIST CHIEF OFFICE 205-45 3'-0" 7'-0" WD-NV MG-1 HMS-1 NONE 15.0

CORRIDOR PROSTHETICS REP OFFICE 206-45 3'-0" 7'-0" WD-NV MG-1 HMS-1 NONE 15.0

CORRIDOR STAFF TOILET 208-45 3'-0" 7'-0" WD-NV MG-1 HMS-1 NONE 12.0

CORRIDOR MECHANICAL 220A-45 6'-0" 7'-0" WD-F WD-F NONE HMS-1 NONE 7.0

CORRIDOR MECHANICAL 220B-45 3'-0" 7'-0" WD-F MG-1 HMS-1 NONE 12.0

CORRIDOR TELECOM 221-45 3'-0" 8'-0" WD-F NONE HMS-1 NONE 10.0 45 Y Y CARD READER, CLOSER, GASKET

CORRIDOR ELEVATOR EQUIP 222-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 12.0

CORRIDOR PARTS STORAGE 223-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 14.0

CORRIDOR SHOE MODIFICATION STORAGE 224-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 14.0

CORRIDOR WHEELCHAIR PARTS STORAGE 225-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 14.0

CORRIDOR DME ACTIVE STORAGE 226-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 14.0

CORRIDOR ELECTRICAL 227-45 3'-0" 7'-0" WD-F MG-1 HMS-1 NONE 12.0

CORRIDOR PROSTHETICS/ ORTHOTICS

MAINTENANCE

228-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 14.0

TRASH PROSTHETICS LAB 1303-45 3'-0" 7'-0" WD-F NONE HMS-1 NONE 12.0

PROSTHETICS LAB CORRIDOR C100A-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 10.0 CARD READER, CLOSER, GASKET, BLAST RESISTANT, 14GA

VERTICALLY STIFFENED

CORRIDOR CORRIDOR C100B-45 3'-8" 7'-0" HM-F NONE HMM-1 NONE 5.0 CLOSER, BLAST RESISTANT, 14GA

VERTICALLY STIFFENED

CORRIDOR CORRIDOR C100C-45 3'-10" 7'-0" WD-GF MG-1 HMS-1 NONE 23.0 Y Y POWER OPERATOR, INSULATED CORRIDOR C101-45 3'-10" 7'-2" AL-GF MG-1 AL-1 NONE 14.0 Y CARD READER, CLOSER, GASKET, BLAST RESISTANT

CORRIDOR STAIR 2 C101-64 3'-6" 7'-0" WD-F NONE HMS-1 NONE 4.0 60 Y Y

CORRIDOR CORRIDOR C103-45 3'-0" 7'-0" HM-F NONE HMM-1 NONE 8.0 CARD READER, CLOSER, GASKET, BLAST RESISTANT

CORRIDOR STAIR 1 S100A-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 3.0 60 Y Y Y

STAIR 1 S100B-45 3'-6" 7'-0" AL-NV LG-2 AL-7 NONE 2.0 CARD READER, CLOSER, INSULATED

DOOR

CORRIDOR STAIR 2 S102A-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 4.0 60 Y Y

STAIR 2 S102B-45 3'-6" 7'-0" AL-NV LG-2 AL-7 NONE 2.0 CARD READER, CLOSER, INSULATED

DOOR

CORRIDOR STAIR 1 S201-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 3.0 60 Y Y

CORRIDOR STAIR 2 S202-45 3'-6" 7'-0" WD-F NONE HMS-1 NONE 3.0 60 Y Y

CORRIDOR WORKSTATION B227-110 3'-0" 7'-0" WD-NV MG-1 HMS-1 NONE 15.0 BUILDING 110 DEDUCT ALTERNATE

1 1/2" = 1'-0"1 TYPICAL PARTITION CONTROL JOINT FRAMING AT DOORS

TYPES - PANELS

TYPES - FRAMES

1 1/2" = 1'-0"2 HM DOOR FRAME IN METAL STUD PARTITION - HEAD

1 1/2" = 1'-0"3 HM DOOR FRAME IN METAL STUD PARTITION - JAMB

3" = 1'-0"4 HM FRAME PROFILES.

3/4" = 1'-0"5 AL-7 MUNTIN DETAIL

Revisions: Date: 09/12/2022

I hereby certify that this plan, specification, or report was prepared by me, or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Name: Steve Schlotthauer

FIRST LEVEL

0"

W21CW1

5'-4" MO

'-2

" M O

2'- 0"

6'- 8"

EQ EQ

IL-1

IL-1

IL-2

IL-1

3'- 6"

4'- 6"

M O

3'-8" MO

BLAST

RESISTANT

CURTAIN WALL

FRAME

C3

C2

C3

C1C1

C1

C1

W8

W6

W1 W1

SECOND LEVEL

14'-0"

W20W16

IL-1

W5

W1

EX

IS

TI

NG

7'-

" M O

3'-8"MO

2'- 0"

8'- 0"

3'-8" MO

EQ

EQ

EQ

EQ

W6

W4

W2

IL-1

W5

W1

W6

W4

W2

FIRST LEVEL

0"

W1 W4

2'-8" MO

EQ

EQ

EQEQ

2'- 2"

6'-

"9'- 1"

M O

EX

IS

T

9'- 4"

M O

EX

IS

T

2'- 2"

7'- 2"

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

3'-8" MO

EQ EQ EQ

EQ

EQ

EQ

EQ

EQ

EQ

W4

W2W3

W6

W1 W5

IL-1

IL-2 WHERE INDICATED

ON FLOOR PLANW7

W4

W2W3

W6

W1

W5

IL-1W7

FIRST LEVEL

0"

W2

9'- 1"

M O

EX

IS

T

6'-

2'-

2"

3'-8" MO

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ EQ EQ

W4

W2W3

W6

W1 W5

IL-1W7

3'- 4 1

/2" 3'-

4 1 /2"

2'- 2"

FIRST LEVEL

0"

SECOND LEVEL

14'-0"

W14

W5

EX

IS

T

EX

IS

T

5'- 0"

M O

7'-

" M O

3'-8" MO

3'-8" MO

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQEQEQ

EQ

EQ

EQEQEQ

EQ

EQ

IL-1

W6

W4

W2

W1 W5 W3

W4

W2

W3

W6

W1 W5

IL-1

FIRST LEVEL

0"

W6

3'-

" M O

EX

IS

T

EQ

EQ

EQ

2'-4" MO

EQ EQ

IL-1

W6

W8

W1

ALL CURTAIN WALL (CW#) SYSTEMS TO BE 7 1/2"D UNLESS NOTED OTHERWISE

ALL 7 1/2" SYSTEM MULLION PROFILES TO BE C1 UNLESS NOTED OTHERWISE.

TOTAL THICKNESS OF CURTAIN WALL MAY VARY, SEE GLAZING TYPES.

CURTAIN WALL NOTES

S1

2" X 4" SYSTEM

LOBBY

INSIDE

OUTSIDE

INSIDE

2"

W1 W2 W3 W4 W5 W6

INSIDEOUTSIDE INSIDEOUTSIDE

INSIDEOUTSIDE

OUTSIDE

INSIDE

OUTSIDE

INSIDE

4"

2" X 4" WINDOW (W#) SYSTEM

INSIDEOUTSIDE

W7

C1

2 1/2" X 7 1/2" SYSTEM

1"

7 1 /2"

C2

OUTSIDE

INSIDE

1"

7 1 /2"

C3

4" OUTSIDE

INSIDE

1"

7 1 /2"

6"OUTSIDE

INSIDE

2 1/2"

2 1/2' X 7 1/2" CURTAIN WALL (CW#) SYSTEM

ALL WINDOWS (W#) SYSTEMS TO BE 4"D UNLESS NOTED OTHERWISE

4" SYSTEM MULLION PROFILES

- SILLS TO BE W4 UNLESS NOTED OTHERWISE

- HEAD TO BE W6 UNLESS NOTED OTHERWISE

- DIVIDED LIGHT MUNTIN TO BE W3 UNLESS NOTED OTHERWISE.

WINDOW NOTES

3/4"

4"

3 9 /16

2 3 /8"

4"4"2"2"

2"

1"

W8

INSIDEOUTSIDE

2"

4"

C4

OUTSIDE

INSIDE

1"

7 1 /2"

8"

C5

OUTSIDE

INSIDE

1"

7 1 /2"

9"

S2

4" X 4" SYSTEM

LOBBY

INSIDE

4"

1"

FIRST LEVEL

0"

W8

EX

IS

T 5'-

0" M

O

3'-8" MO

IL-1

W1

W6

W8

W1

SECOND LEVEL

14'-0"

W10

8'- 0"

M O

EX

IS

T

3'-8" MO

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ EQ EQ

W4

W2

W6

W1

IL-1

W5

W3

SECOND LEVEL

14'-0"

W15

7'-

" M O

EX

IS

T

3'-8" MO

EQ EQ EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

W4

W2

W6

W1

IL-1

W5

W3

SECOND LEVEL

14'-0"

CW2 W9 W12

CW3

FIELD VERIFY

5'-0" MO

4'-

EX

IS

T

ST

ON

E

BA

ND

AL

IG

N W

IT

H

R 2'-6"

8'- 9"

F V

1'- 4"

EQ

EQ

5'-0" MO FV

EQ EQ

8'- 0"

M O

F V

EX

IS

T

EQ

EQ

2'-8" MO FV

EQ EQ

EQ

EQ

EQ

EQ

EQ

EQ

8'- 2"

M O

F V

EX

IS

T

3'-8" MO FV

EQ EQ EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

W4

W2

W6

W1

IL-1

W5

W3

W4

W2

W6

W1

IL-1

W5

W3

C2

C2

C3

C2IL-1

IL-2 C1 C1

C1

C4IL-2

FIRST LEVEL

0"

SF2

8'- 2"

2'- 8"

4'-

3'- 7"

OPENING FOR SLIDING

WINDOW

1'-3" 3'-2" 3'-6" 1'-0 7/8"

8'-11 7/8"

'-1

0"

4'-

MG-1

S1

(TYP)

FIRST LEVEL

0"

SF3

1'- 3"

2'- 9"

6'-

1'- 3"

9'- 7"

3'-6"

1'-2" 1'-2 5/8"

1'-1 3/8"

'-1

0"

MG-1

S1

(TYP)

S2

FIRST LEVEL

0"

SF1

6'-

4'-

0"

2'-5 3/8" 1'-8" 3'-6" 1'-6 1/4"

9'-1 5/8"

3'- 7"

OPENING FOR SLIDING

WINDOW

'-1

0"

MG-1

S1

(TYP)

SECOND LEVEL

14'-0"

CW19

9'- 0"

22'-2 3/4"

EQ EQ EQ EQ EQ

LG-1

C1

C1

C1

CLCL CL CL CL CL

C1 C1 C1 C1 C1

SECOND LEVEL

14'-0"

TOP OF EXISTING MASONRY

25'-10 3/8"

CW18

'-1

0 3 /8"

1'- 0 3

/4" 4'-

5'-0"

2'- 2 1

/4"

IL-2 C1 C1

C1

C5

IL-2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C U s e rs

\P u b lic \D o c u m e n ts \R e v it P ro je c ts

\1

-R g b a rb a ri a e -m n .c o m

.r v t

/8

/2

:2

:5

A

M

AE603

CURTAIN WALL, WINDOW TYPES

AND PROFILES

CONSTRUCT

PROSTHETICS FACILITY

HAMPTON, VA.

590-210

09/02/2022 LA GJB/JT16149

1/4" = 1'-0"

EXTERIOR CURTAIN WALL AND WINDOW TYPES

1 1/2" = 1'-0"1 CURTAIN WALL, STOREFRONT AND WINDOW FRAME PROFILES

1/4" = 1'-0"

EXTERIOR CURTAIN WALL AND WINDOW TYPES

1/4" = 1'-0"

INTERIOR STOREFRONT TYPES

1/4" = 1'-0"

INTERIOR CURTAIN WALL TYPES

Revisions: Date: 09/12/2022

I hereby certify that this plan, specification, or report was prepared by me, or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Name: Steve Schlotthauer

ACCESSIBLE LAVATORY BASIN/BATHROOMS

CARD READER

GRAB BAR

ACCESSIBLE TOILET/WATER CLOSETS

- SEE ELECTRICAL

AND COMMUNICATION DRAWINGS

MIN

2'-6"

WALL AT RECESS

MA

X

2'-

"T O

RI

M

MA

X

2'-

"T O

RI

M

UN

O

3'- 0"

3'-6"MIN

MAX

1'-0"

7"-9"

"-3 6"

MIN

1'-0"

MIN

2'-0"

"-3

6"

SIDE WALL BACK WALL

LAVATORY

HOUSEKEEPING/EVS CLOSET

UTILITY SHELF

SERVICE

RECEPTOR

WATER CONTROLS

MOP HOLDER

4'- 8"

ACCESSIBLE MIRROR

MOP HOLDER

CLEAR FLOOR SPACE

5'-0"MIN

1. SANITARY NAPKIN DISPOSAL. PROVIDE AT UNISEX, & WOMEN'S PATIENT BATHROOMS ONLY.

2. DISPENSERS MAY NOT BE LOCATED BEHIND GRAB BARS.

1. SEE PLAN FOR SPECIFIC LOCATION CONDITION

2. SDISD & PTC - VC

3. * KNEE CLEARANCE

4. SEE ACCESSIBLE MIRROR AT LAV FOR ADDITIONAL INFORMATION

1. UTILITY SHELF 24" LONG UNO

2. WATER CONTROLS AND SERVICE RECEPTOR - SEE MECHANICAL

1. SEE INTERIOR ELEVATIONS FOR

MIRROR SIZE

WALL AT CORNER

WALL CLOCK

-SEE ELECTRICAL DRAWINGS

CLOCK

ACCESSIBLE SOAP AND

HAND SANITIZER DISPENSER

TO OPERATOR

OV

ER

C

OU

NT

ER

" M

AX

4'- 0"

MA

X

ACCESSIBLE PTD

TO TOWEL

SLOT

4'- 0"

MA

X

OV

ER

C

OU

NT

ER

" M

AX

1'-3 1/2"

EQ EQ

ACCESSIBLE LAV

9"

MI

N*

2'-

"T O

RI

M

MA

X

17"-25" TOE CLEARANCE

2'- 3"

MA

X*

8"MIN*

11"MIN*

25" MAX TO CONTROLS

56" @ WALL HUNG WC**

SND

1'- 3"

MI

N

4'- 0"

MA

X

DISPENSER OUTLET

ZONE

WC

LINE OF CLEAR

FLOOR SPACE

"-1

9"

* AT TOILET COMPARTMENTS

** AT TOILET COMPARTMENTS AND SINGLE OCCUPANCY

PLACE HANDLE ON

OPEN SIDE

16"-18"

" T

O

RE

FL

EC

TI

VE

S

UR

FA

CE

1'-4"

SANITARY NAPKIN DISPOSAL

1. SANITARY NAPKIN DISPOSAL. PROVIDE

AT UNISEX, & WOMEN'S PATIENT

BATHROOMS ONLY.

6'- 0"

3'- 0"

7'- 4"

GRAB BAR

ACCESSIBLE BARIATRIC TOILET/WATER CLOSETS

3'-6"MIN

MAX

1'-0"

7"-9"

"-3

6"

MIN

1'-0"

MIN

2'-0"

"-3

6"

SIDE WALL BACK WALL

CLEAR FLOOR SPACE

5'-0"MIN

1. SANITARY NAPKIN DISPOSAL. PROVIDE AT UNISEX, & WOMEN'S PATIENT BATHROOMS ONLY.

2. DISPENSERS MAY NOT BE LOCATED BEHIND GRAB BARS.

59" @ FLOOR MOUNTED WC

1'- 3"

MI

N

4'- 0"

MA

X

DISPENSER OUTLET

ZONE

WC

LINE OF CLEAR

FLOOR SPACE

"-1

9"

PLACE HANDLE ON

OPEN SIDE

2'-0"

2 GLOVE BOXES SHOWN,

REFER TO ELEV FOR

REQ'D QTY. ADDITIONAL

BOXES MOUNTED ABOVE

4'-6"/1370mm.

PROVIDE PARTITION BLOCKING

SHARPS CONTAINER

UN

O

4'- 6"

GLOVE BOX

ADDITIONAL

GLOVE BOXES

AS REQ'D

FLAT TV SCREEN/ MONITORS PC MOUNTING BRACKET

TV EO

UN

O

7'- 2"

UN

O

6'- 6"

EO & VD

BLOCKING

3'- 0"

EQ

EQ

EQ EQ

ADJUSTABLE

MONITOR

BRACKET

ADJUSTABLE VERTICAL SLIDE

MONITOR BRACKET

WALL PHONE

TEL

4'- 4"

ACCESSIBLE BABY CHANGING

STATION

TO BED HEIGHT

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C U s e rs

\P u b lic \D o c u m e n ts \R e v it P ro je c ts

\1

-R g b a rb a ri a e -m n .c o m

.r v t

/8

/2

:2

:5

A

M

AE640

MOUNTING HEIGHTS CONSTRUCT

PROSTHETICS FACILITY

HAMPTON, VA.

590-210

09/02/2022 LA GJB16149

TYPICAL MOUNTING HEIGHTS

Revisions: Date: 09/12/2022

I hereby certify that this plan, specification, or report was prepared by me, or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Name: Steve Schlotthauer

TA

LL

S

TO

RA

GE

C

AB

IN

ET

S

126-45

ORTHO

SUPERVISOR

OFFICE

S102-45

STAIR 2

122-45

STAFF

TOILET

125-45

MECHANICAL

FIRE/H20

C103-45

CORRIDOR

124-45

ELECTRICAL

120-45

TEAM

EVALUATION

C100-45

CORRIDOR

151-45

TELECOM

130E-45

TRASH

130C-45

PROSTHETICS/

ORTHOTICS

FUME130D-45

CAD/ CAM

130B-45

LAB DUST

ROOM

130A-45

LAB

RESTORATION 114-45

CAST

109-45

FACIAL/

BODY

FITTING

STUDIO

111-45

STAFF

TOILET

112-45

SOILED

HOLDING

113-45

DYNAMIC

ALIGNMENT115-45

EQUIPMENT

STORAGE

116-45

FITTING /

EXAM SOFT

GOODS

117-45

FITTING /

EXAM

CUSTOM

FAB

130-45

PROSTHETICS

LAB

108-45

FITTING /

EXAM SOFT

GOODS

S100-45

STAIR 1

107-45

FITTING /

EXAM SOFT

GOODS

106-45

FITTING /

EXAM SOFT

GOODS

105-45

FITTING /

EXAM SOFT

GOODS

104-45

FITTING /

EXAM SOFT

GOODS

103-45

FITTING /

EXAM SOFT

GOODS102-45

PATIENT

TOILET

100-45

LOBBY

101-45

RECEPTION

118-45

PATIENT /

PUBLIC

TOILET

119-45

PATIENT /

PUBLIC

TOILET150-45

ELECTRICAL

123-45

OPEN

OFFICE

C102-45

CORRIDOR

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1 CG1

CG1

CG1

110-45

HAC

CG1

CG1

CG1

C100-45

CORRIDOR

CG1 CG1

FN1 FN1

FN1 FN1

FN1

FN1

FN1

FN3

FN1

FN1

FN1

WP-1

WP-1

WP-1

WP-1

WP-1

WP-1

WP-1

WP-1

WP-1

WP-1

WP-1

WP-1

WP-1

WP-1

WP-1

VWC-2VWC-2

VWC-1

VWC-1VWC-1

WP-2

WP-2

WP-2

WP-2

WP-2

WP-2

VWC-3 VWC-4

VWC-5 VWC-3

WP-2

WP-2

WP-2

WP-2

WP-1

WP-2

VWC-4

VWC-3 WP-2VWC-4

WP-2WP-2

WP-1

WP-1

RWC-1

RWC-1

RWC-1

RWC-1

VWC-2VWC-2

CG1

WP-1

WP-1

1'- 3"

1'- 3"

1'-3"

P-3

P-3

C101-45

CORRIDOR

CG1

CG1

CG1 CG1

CG1

WP-2

WP-2

VWC-5

CG1CG1

RWC-1

RWC-1

CG1CG1CG1CG1CG1CG1 CG1CG1

CG1

CG1

5'- 0"

1. FIELD FINISH VENTS, GRILLES, ACCESS PANELS, PLUG STRIP, BASEBOARD RADIATION

ENCLOSURES, ELECTRICAL PANEL BOARDS (IN FINISHED SPACES AS THEY OCCUR) TO MATCH

SURFACE ON WHICH THEY OCCUR UNLESS OTHERWISE INDICATED. EXCEPTION: ITEMS WITH

FACTORY WHITE FINISH, OCCURRING ON WHITE ACT OR WHITE GYPSUM BOARD CEILING

SHALL NOT BE PAINTED. STAINLESS STEEL ITEMS SHALL NOT BE PAINTED

2. FIELD VERIFY ALL NEW CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO

INSTALLATION

3. LOCATE CHANGES IN FLOOR FINISH MATERIAL UNDER CENTERLINE OF CLOSED DOOR

UNLESS OTHERWISE INDICATED

4. PROVIDE CLEAR SILICONE SEALANT AT PERIMETER OF PLUMBING FLOOR DRAINS, CLEAN

OUTS, ETC IN RESILIENT AND CERAMIC TILE FLOORS

5. PROVIDE SEALANT TO HORIZONTAL AND VERTICAL INTERIOR CERAMIC TILE CORNERS,

COLOR TO MATCH GROUT COLOR

6. PROVIDE SEALANT AT JOINT BETWEEN COUNTER TOP, BACK OR SIDE SPLASH AND WALLS

7. PROVIDE CLEAR SILICONE SEALANT AT THE BASE OF DOOR FRAME TO RESILIENT AND CT

FLOORING, TYP. SEE PLANS AND ROOM FINISH SCHEDULE FOR FLOOR FINISH LOCATIONS

8. HOLLOW METAL DOORS AND FRAMES TO BE PAINTED AS NOTED IN THE FINISH SCHEDULE

9. WOOD: PRE-FINISHED TO MATCH BUILDING STANDARD, REFER TO SPECIFICATION

10. CEILING HEIGHTS AND MATERIALS/FINISHES CALLED OUT IN ROOM FINISH SCHEDULE ARE

FOR ENTIRE CEILING OR MAJORITY OF THAT ROOM, UNLESS OTHERWISE INDICATED. SEE

REFLECTED CEILING PLAN FOR CHANGES IN CEILING MATERIAL AND CEILING HEIGHT. PAINT

ALL SURFACES OF SOFFIT SAME COLOR AS INDICATED

11. COLOR SELECTIONS ARE BASED ON USE OF PRODUCTS INDICATED IN THE PROJECT

MANUAL SPECIFICATION. IF MANUFACTURERS OTHER THAN THOSE INDICATED ARE USED,

ARCHITECT MAY REVISE COLOR SELECTIONS OF OTHER FINISHES TO ENSURE PROPER

COORDINATION

12. PAINT ALL FIRE EXTINGUISHER CABINETS TO MATCH COLOR OF THE ADJACENT WALLS

13. CEILING HEIGHTS ARE MEASURED FROM FINISH FLOOR

14. FOR FLOOR FINISH MATERIALS AND PATTERN, SEE FINISH PLAN

15. SEE INTERIOR ELEVATIONS FOR MORE FINISH INFO

FINISH PLAN GENERAL NOTES

ACT ACOUSTICAL CEILING TILE

CPT MODULAR CARPET TILE

CT CERAMIC TILE

EPY EPOXY FLOORING

GWB (SC) GYPSUM WALLBACK SYSTEMS (SPECIAL COATING)

LVT LUXURY VINYL TILE

P PAINT

PT PORCELAIN TILE (FLOOR AND BASE)

RB RESILIENT BASE

RES RESINOUS EPOXY FLOORING

RES-W RESINOUS/EPOXY WALL/CEILING

RF RUBBER FLOORING

RWC RIGID VINYL WALL COVERING

S SOLID SURFACE

SC SPECIAL COATING

SD STATIC DISSIPATIVE

SP SPECIAL FACED

VWC VINYL WALL COVERING

WP WALL PROTECTION

WSF WELDED SEAM SHEET FLOORING (HEAT WELDED WITH ROD)

ROOM FINISH LEGEND &

ABBREVIATIONS

MATERIAL INSTALL

DIRECTION

KEYNOTECORNER GUARD

WALL PROTECTION

AS INDICATED

NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN

CG AF10

WALLCOVERING AS

INDICATED

CPT-1

LVT-2

LVT-1

LVT-3

FLOOR FINISH LEGEND

SD-1

RES-2RES-1

PT-2

CPT-2

CPT-3

PT-1

WSF-1

FINISH PLAN KEYED NOTES

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

FN1 INSTALL HANDRAIL

FN2 NOT USED

FN3 NOT USED

FN4 NOT USED

FN5 INSTALL TS-5 AT TRANSITION FROM NEW FINISH FLOOR TO EXISTING

FLOORING OUTSIDE THE LIMITS OF CONSTRUCTION.

FN6

FN7

FN8

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C U s e rs

\P u b lic \D o c u m e n ts \R e v it P ro je c ts

\1

-R g b a rb a ri a e -m n .c o m

.r v t

/8

/2

:2

:5

A

M

AF111-B45

FIRST LEVEL FINISH PLAN -

BUILDING 45

CONSTRUCT

PROSTHETICS FACILITY

HAMPTON, VA.

590-210

09/02/2022 MP MP16149

3/16" = 1'-0"1 FIRST LEVEL FINISH PLAN

Revisions: Date: 09/12/2022

I hereby certify that this plan, specification, or report was prepared by me, or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Name: Steve Schlotthauer

224-45

SHOE

MODIFICATION

STORAGE 223-45

PARTS

STORAGE

222-45

ELEVATOR

EQUIP

S202-45

STAIR 2

225-45

WHEELCHAIR

PARTS

STORAGE

226-45

DME ACTIVE

STORAGE

220-45

MECHANICAL

221-45

TELECOM

228-45

PROSTHETICS/

ORTHOTICS

MAINTENANCE

227-45

ELECTRICAL

208-45

STAFF

TOILET

207-45

COPY/

WORK/MAILING

206-45

PROSTHETICS

REP OFFICE

205-45

ASSIST

CHIEF

OFFICE 204-45

CHIEF

OFFICE

203-45

STAFF

LOUNGE

203A-45

LOCKERS

S200-45

STAIR 1

202-45

CONFERENCE

201-45

OPEN

OFFICEOPEN TO

BELOW

FLAT ROOF BELOW

C200-45

CORRIDOR

C200-45

CORRIDOR

VWC-2 VWC-2

CG1

CG1 CG1CG1CG1

CG1CG1

CG1

CG1

CG1

DEDUCT ALTERNATE 3

CPT-1

LVT-2

LVT-1

LVT-3

FLOOR FINISH LEGEND

SD-1

RES-2RES-1

PT-2

CPT-2

CPT-3

PT-1

WSF-1

1. FIELD FINISH VENTS, GRILLES, ACCESS PANELS, PLUG STRIP, BASEBOARD RADIATION

ENCLOSURES, ELECTRICAL PANEL BOARDS (IN FINISHED SPACES AS THEY OCCUR) TO MATCH

SURFACE ON WHICH THEY OCCUR UNLESS OTHERWISE INDICATED. EXCEPTION: ITEMS WITH

FACTORY WHITE FINISH, OCCURRING ON WHITE ACT OR WHITE GYPSUM BOARD CEILING

SHALL NOT BE PAINTED. STAINLESS STEEL ITEMS SHALL NOT BE PAINTED

2. FIELD VERIFY ALL NEW CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO

INSTALLATION

3. LOCATE CHANGES IN FLOOR FINISH MATERIAL UNDER CENTERLINE OF CLOSED DOOR

UNLESS OTHERWISE INDICATED

4. PROVIDE CLEAR SILICONE SEALANT AT PERIMETER OF PLUMBING FLOOR DRAINS, CLEAN

OUTS, ETC IN RESILIENT AND CERAMIC TILE FLOORS

5. PROVIDE SEALANT TO HORIZONTAL AND VERTICAL INTERIOR CERAMIC TILE CORNERS,

COLOR TO MATCH GROUT COLOR

6. PROVIDE SEALANT AT JOINT BETWEEN COUNTER TOP, BACK OR SIDE SPLASH AND WALLS

7. PROVIDE CLEAR SILICONE SEALANT AT THE BASE OF DOOR FRAME TO RESILIENT AND CT

FLOORING, TYP. SEE PLANS AND ROOM FINISH SCHEDULE FOR FLOOR FINISH LOCATIONS

8. HOLLOW METAL DOORS AND FRAMES TO BE PAINTED AS NOTED IN THE FINISH SCHEDULE

9. WOOD: PRE-FINISHED TO MATCH BUILDING STANDARD, REFER TO SPECIFICATION

10. CEILING HEIGHTS AND MATERIALS/FINISHES CALLED OUT IN ROOM FINISH SCHEDULE ARE

FOR ENTIRE CEILING OR MAJORITY OF THAT ROOM, UNLESS OTHERWISE INDICATED. SEE

REFLECTED CEILING PLAN FOR CHANGES IN CEILING MATERIAL AND CEILING HEIGHT. PAINT

ALL SURFACES OF SOFFIT SAME COLOR AS INDICATED

11. COLOR SELECTIONS ARE BASED ON USE OF PRODUCTS INDICATED IN THE PROJECT

MANUAL SPECIFICATION. IF MANUFACTURERS OTHER THAN THOSE INDICATED ARE USED,

ARCHITECT MAY REVISE COLOR SELECTIONS OF OTHER FINISHES TO ENSURE PROPER

COORDINATION

12. PAINT ALL FIRE EXTINGUISHER CABINETS TO MATCH COLOR OF THE ADJACENT WALLS

13. CEILING HEIGHTS ARE MEASURED FROM FINISH FLOOR

14. FOR FLOOR FINISH MATERIALS AND PATTERN, SEE FINISH PLAN

15. SEE INTERIOR ELEVATIONS FOR MORE FINISH INFO

FINISH PLAN GENERAL NOTES

ACT ACOUSTICAL CEILING TILE

CPT MODULAR CARPET TILE

CT CERAMIC TILE

EPY EPOXY FLOORING

GWB (SC) GYPSUM WALLBACK SYSTEMS (SPECIAL COATING)

LVT LUXURY VINYL TILE

P PAINT

PT PORCELAIN TILE (FLOOR AND BASE)

RB RESILIENT BASE

RES RESINOUS EPOXY FLOORING

RES-W RESINOUS/EPOXY WALL/CEILING

RF RUBBER FLOORING

RWC RIGID VINYL WALL COVERING

S SOLID SURFACE

SC SPECIAL COATING

SD STATIC DISSIPATIVE

SP SPECIAL FACED

VWC VINYL WALL COVERING

WP WALL PROTECTION

WSF WELDED SEAM SHEET FLOORING (HEAT WELDED WITH ROD)

ROOM FINISH LEGEND &

ABBREVIATIONS

MATERIAL INSTALL

DIRECTION

KEYNOTECORNER GUARD

WALL PROTECTION

AS INDICATED

NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN

CG AF10

WALLCOVERING AS

INDICATED

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C U s e rs

\P u b lic \D o c u m e n ts \R e v it P ro je c ts

\1

-R g b a rb a ri a e -m n .c o m

.r v t

/8

/2

:2

:0

A

M

AF121-B45

SECOND LEVEL FINISH PLAN -

BUILDING 45

CONSTRUCT

PROSTHETICS FACILITY

HAMPTON, VA.

590-210

09/02/2022 MP MP16149

3/16" = 1'-0"1 SECOND LEVEL FINISH PLAN

Revisions: Date: 09/12/2022

I hereby certify that this plan, specification, or report was prepared by me, or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Name: Steve Schlotthauer

LIM

IT

S

OF

C

ON

ST

RU

CT

IO

N

LIM

IT

S

OF

C

ON

ST

RU

CT

IO

N

LIMITS OF CONSTRUCTION

B246-110

ET

WORKSHOP

B247-110

TECH

OFFICE

B245-110

TECH

OFFICE

B243-110

BIOMED

PARTS

B244-110

HAC

B242-110

BIOMED C2B-5-110

CORRIDOR

C2B-1-110

CORRIDOR

B227-110

WORKSTATION

B216-110

TOILET

B227A-110

BREAK

B229-110

OFFICE

B227B-110

FILES

C2B-4-110

CORRIDOR

B214-110

TELECOM

B226-110

COPY

B228-110

OFFICE

B230-110

OFFICE

B230A-110

STORAGE

B232-110

OFFICE

B234-110

OFFICE

B236-110

OFFICE

B238-110

CONFERENCEB239-110

WORKSTATION

B235-110

WORKSTATION

B231-110

WORKSTATION

S2B-5-110

STAIR

B212-110

ELEC

S2B-2-110

STAIR-2

B219

WOMEN'S

TOILET

B22

STORAGEB223

OFFICE

B225

STORAGE

B224

SHARED

OFFICE

B220

BIO

ENGINEERING

E2B-10

ELEVATOR

B209A

CHASE B209

STORAGE

E2B-11 Room

C2B-10

CORRIDOR

LIMITS OF CONSTRUCTIONLIMITS OF CONSTRUCTION

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CG1

CPT-1

LVT-2

LVT-1

LVT-3

FLOOR FINISH LEGEND

SD-1

RES-2RES-1

PT-2

CPT-2

CPT-3

PT-1

WSF-1

FINISH PLAN KEYED NOTES

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

FN1 INSTALL HANDRAIL

FN2 NOT USED

FN3 NOT USED

FN4 NOT USED

FN5 INSTALL TS-5 AT TRANSITION FROM NEW FINISH FLOOR TO EXISTING

FLOORING OUTSIDE THE LIMITS OF CONSTRUCTION.

FN6

FN7

FN8

ACT ACOUSTICAL CEILING TILE

CPT MODULAR CARPET TILE

CT CERAMIC TILE

EPY EPOXY FLOORING

GWB (SC) GYPSUM WALLBACK SYSTEMS (SPECIAL COATING)

LVT LUXURY VINYL TILE

P PAINT

PT PORCELAIN TILE (FLOOR AND BASE)

RB RESILIENT BASE

RES RESINOUS EPOXY FLOORING

RES-W RESINOUS/EPOXY WALL/CEILING

RF RUBBER FLOORING

RWC RIGID VINYL WALL COVERING

S SOLID SURFACE

SC SPECIAL COATING

SD STATIC DISSIPATIVE

SP SPECIAL FACED

VWC VINYL WALL COVERING

WP WALL PROTECTION

WSF WELDED SEAM SHEET FLOORING (HEAT WELDED WITH ROD)

ROOM FINISH LEGEND &

ABBREVIATIONS

MATERIAL INSTALL

DIRECTION

KEYNOTECORNER GUARD

WALL PROTECTION

AS INDICATED

NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN

CG AF10

WALLCOVERING AS

INDICATED

1. FIELD FINISH VENTS, GRILLES, ACCESS PANELS, PLUG STRIP, BASEBOARD RADIATION

ENCLOSURES, ELECTRICAL PANEL BOARDS (IN FINISHED SPACES AS THEY OCCUR) TO MATCH

SURFACE ON WHICH THEY OCCUR UNLESS OTHERWISE INDICATED. EXCEPTION: ITEMS WITH

FACTORY WHITE FINISH, OCCURRING ON WHITE ACT OR WHITE GYPSUM BOARD CEILING

SHALL NOT BE PAINTED. STAINLESS STEEL ITEMS SHALL NOT BE PAINTED

2. FIELD VERIFY ALL NEW CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO

INSTALLATION

3. LOCATE CHANGES IN FLOOR FINISH MATERIAL UNDER CENTERLINE OF CLOSED DOOR

UNLESS OTHERWISE INDICATED

4. PROVIDE CLEAR SILICONE SEALANT AT PERIMETER OF PLUMBING FLOOR DRAINS, CLEAN

OUTS, ETC IN RESILIENT AND CERAMIC TILE FLOORS

5. PROVIDE SEALANT TO HORIZONTAL AND VERTICAL INTERIOR CERAMIC TILE CORNERS,

COLOR TO MATCH GROUT COLOR

6. PROVIDE SEALANT AT JOINT BETWEEN COUNTER TOP, BACK OR SIDE SPLASH AND WALLS

7. PROVIDE CLEAR SILICONE SEALANT AT THE BASE OF DOOR FRAME TO RESILIENT AND CT

FLOORING, TYP. SEE PLANS AND ROOM FINISH SCHEDULE FOR FLOOR FINISH LOCATIONS

8. HOLLOW METAL DOORS AND FRAMES TO BE PAINTED AS NOTED IN THE FINISH SCHEDULE

9. WOOD: PRE-FINISHED TO MATCH BUILDING STANDARD, REFER TO SPECIFICATION

10. CEILING HEIGHTS AND MATERIALS/FINISHES CALLED OUT IN ROOM FINISH SCHEDULE ARE

FOR ENTIRE CEILING OR MAJORITY OF THAT ROOM, UNLESS OTHERWISE INDICATED. SEE

REFLECTED CEILING PLAN FOR CHANGES IN CEILING MATERIAL AND CEILING HEIGHT. PAINT

ALL SURFACES OF SOFFIT SAME COLOR AS INDICATED

11. COLOR SELECTIONS ARE BASED ON USE OF PRODUCTS INDICATED IN THE PROJECT

MANUAL SPECIFICATION. IF MANUFACTURERS OTHER THAN THOSE INDICATED ARE USED,

ARCHITECT MAY REVISE COLOR SELECTIONS OF OTHER FINISHES TO ENSURE PROPER

COORDINATION

12. PAINT ALL FIRE EXTINGUISHER CABINETS TO MATCH COLOR OF THE ADJACENT WALLS

13. CEILING HEIGHTS ARE MEASURED FROM FINISH FLOOR

14. FOR FLOOR FINISH MATERIALS AND PATTERN, SEE FINISH PLAN

15. SEE INTERIOR ELEVATIONS FOR MORE FINISH INFO

FINISH PLAN GENERAL NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C U s e rs

\P u b lic \D o c u m e n ts \R e v it P ro je c ts

\1

-R g b a rb a ri a e -m n .c o m

.r v t

/8

/2

:2

:0

A

M

AF121-B110

SECOND LEVEL FINISH PLAN -

BUILDING 110

CONSTRUCT

PROSTHETICS FACILITY

HAMPTON, VA.

590-210

09/02/2022 MP MP16149

1/8" = 1'-0"1 SECOND LEVEL FLOOR PLAN - BUILDING 110 (DEDUCT ALTERNATE 1)

FN5

Revisions: Date: 09/12/2022

I hereby certify that this plan, specification, or report was prepared by me, or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.

Name: Steve Schlotthauer

1. FIELD FINISH VENTS, GRILLES, ACCESS PANELS, PLUG STRIP, BASEBOARD RADIATION

ENCLOSURES, ELECTRICAL PANEL BOARDS (IN FINISHED SPACES AS THEY OCCUR) TO MATCH

SURFACE ON WHICH THEY OCCUR UNLESS OTHERWISE INDICATED. EXCEPTION: ITEMS WITH

FACTORY WHITE FINISH, OCCURRING ON WHITE ACT OR WHITE GYPSUM BOARD CEILING

SHALL NOT BE PAINTED. STAINLESS STEEL ITEMS SHALL NOT BE PAINTED

2. FIELD VERIFY ALL NEW CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO

INSTALLATION

3. LOCATE CHANGES IN FLOOR FINISH MATERIAL UNDER CENTERLINE OF CLOSED DOOR

UNLESS OTHERWISE INDICATED

4. PROVIDE CLEAR SILICONE SEALANT AT PERIMETER OF PLUMBING FLOOR DRAINS, CLEAN

OUTS, ETC IN RESILIENT AND CERAMIC TILE FLOORS

5. PROVIDE SEALANT TO HORIZONTAL AND VERTICAL INTERIOR CERAMIC TILE CORNERS,

COLOR TO MATCH GROUT COLOR

6. PROVIDE SEALANT AT JOINT BETWEEN COUNTER TOP, BACK OR SIDE SPLASH AND WALLS

7. PROVIDE CLEAR SILICONE SEALANT AT THE BASE OF DOOR FRAME TO RESILIENT AND CT

FLOORING, TYP. SEE PLANS AND ROOM FINISH SCHEDULE FOR FLOOR FINISH LOCATIONS

8. HOLLOW METAL DOORS AND FRAMES TO BE PAINTED AS NOTED IN THE FINISH SCHEDULE

9. WOOD: PRE-FINISHED TO MATCH BUILDING STANDARD, REFER TO SPECIFICATION

10. CEILING HEIGHTS AND MATERIALS/FINISHES CALLED OUT IN ROOM FINISH SCHEDULE ARE

FOR ENTIRE CEILING OR MAJORITY OF THAT ROOM, UNLESS OTHERWISE INDICATED. SEE

REFLECTED CEILING PLAN FOR CHANGES IN CEILING MATERIAL AND CEILING HEIGHT. PAINT

ALL SURFACES OF SOFFIT SAME COLOR AS INDICATED

11. COLOR SELECTIONS ARE BASED ON USE OF PRODUCTS INDICATED IN THE PROJECT

MANUAL SPECIFICATION. IF MANUFACTURERS OTHER THAN THOSE INDICATED ARE USED,

ARCHITECT MAY REVISE COLOR SELECTIONS OF OTHER FINISHES TO ENSURE PROPER

COORDINATION

12. PAINT ALL FIRE EXTINGUISHER CABINETS TO MATCH COLOR OF THE ADJACENT WALLS

13. CEILING HEIGHTS ARE MEASURED FROM FINISH FLOOR

14. FOR FLOOR FINISH MATERIALS AND PATTERN, SEE FINISH PLAN

15. SEE INTERIOR ELEVATIONS FOR MORE FINISH INFO

FINISH PLAN GENERAL NOTES

ACT ACOUSTICAL CEILING TILE

CPT MODULAR CARPET TILE

CT CERAMIC TILE

EPY EPOXY FLOORING

GWB (SC) GYPSUM WALLBACK SYSTEMS (SPECIAL COATING)

LVT LUXURY VINYL TILE

P PAINT

PT PORCELAIN TILE (FLOOR AND BASE)

RB RESILIENT BASE

RES RESINOUS EPOXY FLOORING

RES-W RESINOUS/EPOXY WALL/CEILING

RF RUBBER FLOORING

RWC RIGID VINYL WALL COVERING

S SOLID SURFACE

SC SPECIAL COATING

SD STATIC DISSIPATIVE

SP SPECIAL FACED

VWC VINYL WALL COVERING

WP WALL PROTECTION

WSF WELDED SEAM SHEET FLOORING (HEAT WELDED WITH ROD)

ROOM FINISH LEGEND &

ABBREVIATIONS

MATERIAL INSTALL

DIRECTION

KEYNOTECORNER GUARD

WALL PROTECTION

AS INDICATED

NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN

CG AF10

WALLCOVERING AS

INDICATED

3'- 0"

HANDRAIL

WP-1

RB-2

2'- 7"

TR-1

EQ EQ

DR (WHERE APPLICABLE)

RESIL FLG AS SPECIFIED

TRANSITION STRIP, TS-2

CPT AS

SPECIFIED

CONC SLAB

EQ EQ

DR (WHERE APPLICABLE)

CERAMIC TILE AS SPECIFIED

TRANSITION STRIP, TS-1

RESILIENT

FLG AS

SPECIFIED

CONC SLAB

EQ EQ

DR (WHERE APPLICABLE)

POURED EPOXY FLG - RES-2

TRANSITION STRIP, TS-4

CONC SLAB

DOOR

RESIL FLG AS

SPECIFIED

EQ EQ

DR (WHERE APPLICABLE)

WSF FLG AS

SPECIFIED

HEAT WELD FL MATL AS

REQ/D

CONC SLAB

LVT FLG AS

SPECIFIED

CPT TO RESIL FLG

LVT TO CT

RESIL FLG TO POURED EPOXY (RES-2)LVT FLG TO WSF FLG

CL

DOOR

CL

DOOR

CL

DOOR

CL

EQ EQ

DR (WHERE APPLICABLE)

LVT FLG AS

SPECIFIED

HEAT WELD FL MATL AS

REQ/D

CONC SLAB

LVT FLG AS

SPECIFIED

LVT FLG TO LVT FLG

DOOR

CL

EQ EQ

DR (WHERE APPLICABLE)

RESIL FLG AS SPECIFIED

TRANSITION STRIP, TS-5

RES-1 FLG, CONCRETE,

OR EXIST FLG AS

SCHEDULED

CONC SLAB

RESINOUS FLOORING, CONCRETE

OR EXIST FLG TO RESIL FLG

DOOR

CL

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C U s e rs

\P u b lic \D o c u m e n ts \R e v it P ro je c ts

\1

-R g b a rb a ri a e -m n .c o m

.r v t

/8

/2

:2

:0

A

M

AF600

MATERIAL AND ROOM FINISH

SCHEDULE & FINISH DETAILS

CONSTRUCT

PROSTHETICS FACILITY

HAMPTON, VA.

590-210

09/02/2022 MP MP16149

ROOM FINISH SCHEDULE - BLDG 45

NO. NAME FLOOR FINISH BASE FINISH

WALL FINISH

CEILING FINISH REMARKSNORTH EAST SOUTH WEST

100-45 LOBBY LVT-1/LVT-2 RB-2 N/A WD-1 VWC-1/P-1 VWC-1/P-1 ACT-1

101-45 RECEPTION LVT-1 RB-1 P-1 P-1 N/A P-1 GYP BD

102-45 PATIENT TOILET PT-1 PR-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 GYP BD (P-5)

103-45 FITTING / EXAM SOFT GOODS LVT-1 RB-1 VWC-3 P-5 WP-2/P-5 WP-2/P-5 ACT-1

104-45 FITTING / EXAM SOFT GOODS LVT-1 RB-1 VWC-4 P-5 WP-2/P-5 WP-5/P-5 ACT-1

105-45 FITTING / EXAM SOFT GOODS LVT-1 RB-1 WP-2/P-5 P-5 WVC-5 WP-2/P-5 ACT-1

106-45 FITTING / EXAM SOFT GOODS LVT-1 RB-1 VWC-3 P-5 WP-2/P-5 WP-2/P-5 ACT-1

107-45 FITTING / EXAM SOFT GOODS LVT-1 RB-1 VWC-4 P-5 WP-2/P-5 WP-2/P-5 ACT-1

108-45 FITTING / EXAM SOFT GOODS LVT-1 RB-1 P-5 VWC-5 WP-2/P-5 WP-2/P-5 ACT-1

109-45 FACIAL/ BODY FITTING STUDIO LVT-1 RB-1 P-4 P-4 P-1 P-1 ACT-1

110-45 HAC PT-2 CT-1 CT-1/P-1 CT-1/P-1 CT-1/P-1 CT-1/P-1 ACT-1

111-45 STAFF TOILET PT-1 PR-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 GYP BD (P-5)

112-45 SOILED HOLDING WSF-1 WSF-1 RWC-1/SC-1 RWC-1/SC-1 RWC-1/SC-1 RWC-1/SC-1 ACT-1

113-45 DYNAMIC ALIGNMENT LVT-1 RB-1 P-1 P-2 P-2 P-1 ACT-1

114-45 CAST LVT-1 RB-1 P-1 P-3 P-3 P-1 ACT-1

115-45 EQUIPMENT STORAGE LVT-3 RB-1 P-3 P-3 P-3 P-3 ACT-1

117-45 FITTING / EXAM CUSTOM FAB LVT-1 RB-1 WP-2/P-5 P-5 VWC-3 WP-2/P-5 ACT-1

118-45 PATIENT / PUBLIC TOILET PT-1 PR-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 GYP BD (P-5) 119-45 PATIENT / PUBLIC TOILET PT-1 PR-3 PT-3/P-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 GYP BD (P-5)

120-45 TEAM EVALUATION CPT-1 RB-1 P-4 P-4 P-1 P-1 ACT-1

122-45 STAFF TOILET PT-1 PR-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 GYP BD (P-5)

123-45 OPEN OFFICE CPT-1 RB-1 P-1 N/A P-1 P-1 ACT-1

124-45 ELECTRICAL RES-1 RB-1 P-3 P-3 P-3 P-3 EXPOSED

125-45 MECHANICAL FIRE/H20 RES-1 RB-1 P-3 P-3 P-3 P-3 EXPOSED

126-45 ORTHO SUPERVISOR OFFICE CPT-1 RB-1 P-4/P-1 P-4/P-1 P-4/P-1 P-4/P-1 ACT-1 P-4 TO 8'8", P-1 ABOVE

130-45 PROSTHETICS LAB LVT-3 RB-1 P-5 P-3 P-5 P-5 ACT-1 SEE FINISH PLAN

130A-45 LAB RESTORATION LVT-3 RB-1 P-3 P-5 P-5 P-5 ACT-1 SEE FINISH PLAN

130B-45 LAB DUST ROOM LVT-3 RB-1 P-8 P-8 P-8 P-8 ACT-1

130C-45 PROSTHETICS/ ORTHOTICS FUME LVT-3 RB-1 P-8 P-8 P-8 P-8 ACT-1

130D-45 CAD/ CAM LVT-3 RB-1 P-8 P-8 P-8 P-8 ACT-1

130E-45 TRASH LVT-3 RB-1 RWC-1/P-5 RWC-1/P-5 RWC-1/P-5 RWC-1/P-5 ACT-1

150-45 ELECTRICAL RES-1 RB-1 P-8 P-8 P-8 P-8 EXPOSED

151-45 TELECOM SD-1 RB-1 P-5 FP-1 FP-1 FP-1 EXPOSED

201-45 OPEN OFFICE CPT-1 RB-1 P-1 N/A P-1 P-1 ACT-1

202-45 CONFERENCE CPT-1 RB-1 P-4 P-1 P-1 P-4 ACT-1

203-45 STAFF LOUNGE LVT-2 RB-1 P-2 P-2 P-4 P-4 ACT-1

203A-45 LOCKERS LVT-2 RB-1 P-1 P-1 P-1 P-1 ACT-1

204-45 CHIEF OFFICE CPT-1 RB-1 P-4/P-1 P-4/P-1 P-4/P-1 P-4/P-1 ACT-1

205-45 ASSIST CHIEF OFFICE CPT-1 RB-1 P-2/P-1 P-2/P-1 P-2/P-1 P-2/P-1 ACT-1

206-45 PROSTHETICS REP OFFICE CPT-1 RB-1 P-3/P-1 P-3/P-1 P-3/P-1 P-3/P-1 ACT-1

207-45 COPY/ WORK/MAILING LVT-2 RB-1 P-1 P-1 P-1 P-1 ACT-1

208-45 STAFF TOILET LVT-2 PT-1 PR-1 PT-3/P-1 PT-3/P-1 PT-3/P-1 GYP BD (P-5)

220-45 MECHANICAL RES-2 RES-2 P-5 P-5 P-5 P-5 EXPOSED DEDUCT ALTERNATE 3

221-45 TELECOM SD-1 RB-1 FP-1 FP-1 FP-1 P-5 EXPOSED

222-45 ELEVATOR EQUIP LVT-3 RB-1 P-5 P-5 P-5 P-5 EXPOSED

223-45 PARTS STORAGE LVT-3 RB-1 P-5 P-5 P-5 P-5 ACT-1

224-45 SHOE MODIFICATION STORAGE LVT-3 RB-1 P-5 P-5 P-5 P-5 ACT-1

225-45 WHEELCHAIR PARTS STORAGE LVT-3 RB-1 P-5 P-5 P-5 P-5 ACT-1

226-45 DME ACTIVE STORAGE LVT-3 RB-1 P-5 P-5 P-5 P-5 ACT-1

227-45 ELECTRICAL RES-1 RB-1 P-5 P-5 P-5 P-5 EXPOSED

228-45 PROSTHETICS/ ORTHOTICS MAINTENANCE LVT-3 LVT-3 P-5 P-5 P-5 P-5 ACT-1

C100-45 CORRIDOR LVT-1/LVT-2 RB-2 WP-1/P-1 WP-1/P-1 WP-1/P-1 WP-1/P-1 ACT-1

C101-45 CORRIDOR CPT-2 RB-1 RWC-1/P-1 RWC-1/P-1 RWC-1/P-1 RWC-1/P-1 ACT-1

C102-45 CORRIDOR LVT-1/LVT-2 RB-1 WP-2/P-1 WP-2/P-1 WP-2/P-1 WP-2/P-1/VWC-2 ACT-1

C103-45 CORRIDOR LVT-2 RB-1 P-1 VWC-2/P-1 P-1 P-1 ACT-1

C200-45 CORRIDOR LVT-1 RB-1 P-1 P-1/WVC-2 P-1 P-1 ACT-1

S100-45 STAIR 1 N/A RB-1 P-8 P-8 P-8 P-8 EXPOSED

S102-45 STAIR 2 N/A RB-1 P-8 P-8 P-8 P-8 EXPOSED

S200-45 STAIR 1 N/A RB-1 P-8 P-8 P-8 P-8 EXPOSED

S202-45 STAIR 2 N/A RB-1 P-8 P-8 P-8 P-8 EXPOSED

ROOM FINISH SCHEDULE - BLDG 110

NO. NAME FLOOR FINISH BASE FINISH

WALL FINISH

CEILING FINISH REMARKSNORTH EAST SOUTH WEST

B226-110 COPY LVT-3 RB-1 P-1 P-1 P-1 P-1 ACT-1

B227-110 WORKSTATION CPT-3 RB-1 P-4 P-4 P-4 P-4 ACT-1

B227A-110 BREAK LVT-3 RB-1 P-4 P-1 P-1 P-1 ACT-1

B227B-110 FILES LVT-3 RB-1 P-1 P-1 P-1 P-1 ACT-1

B228-110 OFFICE CPT-3 RB-1 P-1 P-1 P-1 P-1 ACT-1

B229-110 OFFICE CPT-3 RB-1 P-1 P-1 P-1 P-1 ACT-1

B230-110 OFFICE CPT-3 RB-1 P-1 P-1 P-1 P-1 ACT-1

B230A-110 STORAGE LVT-3 RB-1 P-3 P-3 P-3 P-3 ACT-1

B231-110 WORKSTATION CPT-3 RB-1 P-4 P-1 P-1 P-1 ACT-1

B232-110 OFFICE CPT-3 RB-1 P-1 P-1 P-1 P-4 ACT-1

B234-110 OFFICE CPT-3 RB-1 P-1 P-1 P-1 P-2 ACT-1

B235-110 WORKSTATION CPT-3 RB-1 P-2 P-1 P-1 P-1 ACT-1

B236-110 OFFICE CPT-3 RB-1 P-1 P-1 P-1 P-4 ACT-1

B238-110 CONFERENCE CPT-3 RB-1 P-1 P-4 P-1 P-4 ACT-1

B239-110 WORKSTATION CPT-3 RB-1 P-4 P-1 P-1 P-1 ACT-1

B242-110 BIOMED LVT-3 RB-1…