About this file

This document is a solicitation (Solicitation Number: 47PD0224R0048) issued by the General Services Administration (GSA) Public Buildings Service Region 3 for Construction Manager as Constructor (CMc) Services for the Phases 2-5 Repairs and Alterations Prospectus for the U.S. Courthouse in Clarksburg, West Virginia. The project scope includes major renovations to the interior finishes, mechanical, electrical, and plumbing (MEP) systems, stairs, elevators, courtrooms, judges' chambers, clerk's space, and U.S. Marshals Service (USMS) space. The government intends to deliver this requirement using the CMc project delivery method with a Guaranteed Maximum Price (GMP) contract, Construction Contingency Allowance (CCA), and shared savings. The solicitation is subject to the mandatory use of a Project Labor Agreement. The technical evaluation factors are listed in descending order of importance and are significantly more important than price. The submission includes two phases, with Phase I technical proposals due on August 30, 2024, and Phase II price proposals due on a date to be announced. The estimated total construction cost for the project falls within the range of $40,000,000.00 to $50,000,000.00.

View the file

Other files

File Type Posted
47PD0224R0048 Clarksburg Construction Phase 2-5 CMc Amendment 0001 8 26 2024.pdf PDF
47PD0224R0048 Clarksburg Construction Phase 2-5 CMc RFI Log Amendment 0001 8 26 2024.xlsx XLSX spreadsheet
47PD0224R0048 Turn-over Checklist in Standard PDF.pdf PDF
47PD0224R0048 PDRI Participants Guide.pdf PDF
47PD0224R0048 CMc Services for Clarksburg Courthouse Modernization Phases 2-5 Project Form 101 7 24 2024.pdf PDF
47PD0224R0048 CMc Services for Clarksburg Courthouse Modernization Phases 2-5 Project Form 301 7 24 2024.pdf PDF
47PD0224R0048 Partnering_FAQs_Final_06112020.docx DOCX document
47PD0224R0048 Copy of 2 1969 Construction Drawings S.PME.FP.pdf PDF
47PD0224R0048 Terracon geotech report - Clarksburg CH - 2020-09-15.pdf PDF
47PD0224R0048 CMc Services for Clarksburg Courthouse Modernization Phases 2-5 Project Form 201 7 24 2024.pdf PDF
47PD0224R0048 NDWV Courthouse Contractor Form.pdf PDF
47PD0224R0048 PDRI Faciltators Guide.pdf PDF
47PD0224R0048 PDRI Explanation and Implementation Requirements and Recommendations.pdf PDF
47PD0224R0048 Past Performance and Sub Contracting Form.pdf PDF
47PD0224R0048 Site Assessment_2018-10-03_Phase I Report_Clarksburg Courthouse_Final.pdf PDF
47PD0224R0048 Latest Concept Plans.pdf PDF
47PD0224R0048 Copy of 1 1969 Construction Drawings.pdf PDF
47PD0224R0048 PDRI Buildings_v4.xls XLS spreadsheet
47PD0224R0048 Submission 4 - Volume 2.pdf PDF
Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FI

LE

N

AM

E:

OU

R

RE

F:

PL

OT

D

AT

E:

1/1

7/2

4 2 :18

:24 P

M

4.5

FA

1.D W

G

CONFORMED CONSTRUCTION SET

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

ABBREVIATIONSSYMBOLS

MANUAL PULL STATIONF

WATERFLOW SWITCHWF

TAMPER SWITCHTS

AIM ADDRESSABLE INPUT MODULE/MONITOR MODULE

AOM ADDRESSABLE OUTPUT MODULE/CONTROL MODULE

NAP NOTIFICATION APPLIANCE POWER PANEL

DIGITAL ALARM COMMUNICATION TRANSMITTERDACT

SMOKE DETECTOR; CEILING MOUNT

SPEAKER; CEILING MOUNTS

SPEAKER / STROBE; CEILING MOUNT

CD = CANDELA RATING

CD

LCD LIQUID CRYSTAL DISPLAY ANNUNCIATOR

BATT BATTERY CABINET

AREA OF WORK

A AMPERES

AC ABOVE CEILING

AS ASPIRATING SMOKE

ADS ACOUSTICALLY DISTINGUISHABLE SPACE

AFF ABOVE FINISHED FLOOR

AHJ AUTHORITY HAVING JURISDICTION

AMP AMPLIFIER

AWG AMERICAN WIRE GAUGE

C CEILING MOUNT

CL CEILING LEVEL

D DRAIN

DN DOWN

ELEV. ELEVATOR

EMT ELECTRICAL METALLIC TUBING

ETR EXISTING TO REMAIN

(E) EXISTING

F FIRE LINE

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FATC FIRE ALARM TERMINAL CABINET

LOC LOCAL OPERATING CONSOLE

MNS MASS NOTIFICATION SYSTEM

NAC NOTIFICATION APPLIANCE CIRCUIT

N.I.C. NOT IN CONTRACT

NICET NATIONAL INSTITUTE FOR

CERTIFICATION IN ENGINEERING

TECHNOLOGIES

P PHOTOELECTRIC

SLC SIGNALING LINE CIRCUIT

SP SPRINKLER PIPING

TR TAMPER-RESISTANT

TYP. TYPICAL

U UNDER FLOOR

WP WEATHERPROOF

MODIFICATION OF THE FIRE ALARM SYSTEM IN

THIS AREA IS NOT IN CONTRACT (N.I.C.)

FACP FIRE ALARM CONTROL PANEL

SURGE PROTECTORSPD

DUCT DETECTOR

GENERAL SYMBOLS

FA101

N

8'0 1/8"=1'-0"

UNIQUE PLAN OR

DETAIL NUMBER

ON THIS DRAWING NORTH ARROW

NAME OF PLAN OR DETAIL

ALL DRAWINGS WHERE

THIS DETAIL IS

REFERENCED FROM

GRAPHIC SCALE OF

THIS PLAN OR DETAIL

SECTION IDENTIFICATION

INDICATES DIRECTION

OF CUTTING PLANE

NUMBER INDICATES SECTION

SHEET NUMBER WHERE

SECTION IS DRAWN

2-PART REFERENCE DETAIL IDENTIFICATION:

SHEET NUMBER WHERE

DETAIL/SECTION IS DRAWN

NUMBER INDICATES

DETAIL/SECTION

FLOOR PLAN

FA101,FA1022

FLOOR PLAN AND DETAIL TITLES:

FA101

N

(E)

REVISION CLOUD WITH REVISION

NUMBER DESIGNATION

BREAKLINE

MATCHLINE DESIGNATIONM A T C H L I N E A-A

EXISTING

POINT OF CONNECTION TO EXISTING

POINT OF TERMINATION OF REMOVAL

NOTE NUMBER#

ARROW INDICATES TRUE NORTH

AND/OR PROJECT NORTH.

ROOM NUMBER

COLUMN LINE NUMBER

NORTH ARROW

FIRE ALARM ZONE

ELECTRONIC ALARM BELL

SPRINKLER ZONE CONTROL ASSEMBLYZCA

STROBE; CEILING MOUNT

CD = CANDELA RATING

CD

DH DOOR HOLD

FIRE ALARM REQUIREMENTS

1. PROVIDE VOICE FIRE ALARM AND DETECTION SYSTEM AS INDICATED ON THE FLOOR PLANS. PROVIDE SYSTEM IN

ACCORDANCE WITH 2018 EDITION P100 FIRE PROTECTION FOR FACILITIES AND 2019 EDITION OF NFPA 72 FIRE

ALARM AND SIGNALING CODE.

2. RETAIN THE EXISTING SIEMENS FIREFINDER XLS FIRE ALARM CONTROL PANEL IN THE BASEMENT TO SERVE

EXISTING FIRE ALARM EQUIPMENT OUTSIDE THE SCOPE OF WORK.

3. PROVIDE CLASS X WIRING FOR RISER AND CLASS B WIRING FOR SLC, NAC, AND AMP CIRCUIT. PROVIDE TWO DISTINCT NAC AND AMP CIRCUITS ON THE FIRST FLOOR. PROVIDE DEDICATED SLC FOR THE FIRST FLOOR. PROVIDE MINIMUM 18 AWG FOR SLC, MINIMUM 16 FOR NAC, AND FOLLOW MANUFACTURER GUIDELINES FOR AMPLIFIER

CIRCUIT SIZE.

4. INSTALL FIRE ALARM CONDUCTORS IN MINIMUM 3/4-INCH DIAMETER EMT CONDUIT. CONDUIT MUST BE RED AND

MUST NOT EXCEED THE NATIONAL ELECTRICAL CODE MAXIMUM FILL CAPACITY.

5. PROVIDE CONDUCTORS IN EMT. EXPOSED WIRING WILL NOT BE PERMITTED IN ANY PORTION OF THE BUILDING.

FLEXIBLE METALLIC CONDUIT NOT EXCEEDING 6 FEET IS PERMITTED FOR TERMINATIONS AT DEVICES. ROUTE EMT

CONDUIT TIGHT TO STRUCTURE.

6. PLACE EQUIPMENT AT CENTER OF ACOUSTICAL CEILINGS TILES. SEE ARCHITECTURAL DRAWINGS FOR REFLECTED

CEILING PLAN PATTERN DESIGNATIONS.

7. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO BE USED FOR COMPLETE SYSTEM DESIGN.

COORDINATE SYSTEM COMPONENTS WITH ALL OTHER DISCIPLINES AND TRADES.

8. PROVIDE A FIRE ALARM SYSTEM DESIGNER WITH A MINIMUM NICET LEVEL III CERTIFICATION IN FIRE ALARM SYSTEM TECHNOLOGY OR A LICENSED PROFESSIONAL FIRE PROTECTION ENGINEER RESPONSIBLE FOR THE FIRE ALARM

SYSTEM DESIGN.

9. CHANGES TO THE DESIGN AND EQUIPMENT INSTALLATION IS THE RESPONSIBILITY OF CONTRACTOR. PROVIDE

DESIGN SERVICES OF A LICENSED PROFESSIONAL FIRE PROTECTION ENGINEER.

10. EXPOSED WIRING WILL NOT BE PERMITTED IN ANY PORTION OF THE BUILDING. FLEXIBLE METALLIC CONDUIT NOT EXCEEDING 6 FEET IS PERMITTED FOR TERMINATIONS AT DEVICES. ROUTE EMT CONDUIT TIGHT TO STRUCTURE.

11. T-TAPS ARE NOT PERMITTED. CONDUIT TERMINATIONS MUST BE ON SCREW TERMINALS OF SYSTEM COMPONENT.

WIRE NUTS ARE PROHIBITED.

12. PROVIDE A LABEL FOR EACH WIRE/CIRCUIT (WITHIN ALL PANELS, CABINETS AND JUNCTION BOXES) INDICATING IT'S PURPOSE AND LOCATION. LABELS MUST BE A MINIMUM FONT SIZE OF 1/4" AND ARIAL NARROW. EXAMPLE OF A

FIRST FLOOR SIGNALING LINE CIRCUIT ONE OF TWO IS SLC-CIR1-FL1.

13. PROVIDE 25% ADDITIONAL CIRCUIT CAPACITY FOR STROBES AND SPEAKERS.

14. VISUAL NOTIFICATION WILL BE STROBES. AUDIBLE NOTIFICATION WILL BE SPEAKERS. EQUIPMENT WILL BE WHITE, VISUAL DEVICES WILL HAVE "ALERT" LETTERING.

15. PROVIDE TAMPER-RESISTANT STROBES IN PRISONER SPACES PER USMS PUBLICATION 64. DO NOT PROVIDE FIRE

ALARM NOTIFICATION DEVICES IN DETENTION CELLS.

16. PANELS MUST BE FACTORY PAINTED RED.

17. SEAL WALL AND FLOOR PENETRATIONS WITH A UL LISTED FIRESTOPPING ASSEMBLY. FIRESTOPPING SYSTEM MUST

MATCH THE RATING OF THE PENETRATED WALL/FLOOR.

18. ALL REQUIRED OUTAGES OF THE FIRE ALARM SYSTEM SHALL BE COORDINATED THROUGH THE CONTRACTING OFFICER NOT LESS THAN 15 WORKING DAYS IN ADVANCE. THE GOVERNMENT WILL PROVIDE THE REQUESTED OUTAGE AND ASSOCIATED RESTORATION OF THE FIRE ALARM SYSTEM. THE GOVERNMENT WILL IDENTIFY TO THE CONTRACTOR WHAT CIRCUITS/DEVICES HAVE BEEN TAKEN OUT OF SERVICE ONCE THE OUTAGE HAS BEEN MADE.

THIS WORK SHALL BE PERFORMED BY THE CONTRACTOR. OUTAGES DO NOT INCLUDE CONNECTION OF NEW FIRE ALARM DEVICES, AND/OR WIRING TO EXISTING SYSTEMS, OR PROGRAMMING CHANGES NECESSARY TO

ACCOMMODATE NEW WORK.

19. AN EXCLUSIVE GOVERNMENT CONTRACTOR/VENDOR RESPONSIBLE FOR MAINTAINING GOVERNMENT FIRE ALARM SYSTEMS SHALL BE OBTAINED FOR TIE IN OF NEW WORK AND/OR REPROGRAMMING OF OPERATING, EXISTING FIRE

ALARM, AT CONTRACTORS COST.

12. A FIRE WATCH, AT CONTRACTOR'S COST, WILL BE CONDUCTED CONTINUOUSLY THROUGHOUT THE DURATION OF THE OUTAGE IN ALL AREAS AFFECTED BY THE OUTAGE. FINDINGS/COMMENTS WILL BE DOCUMENTED HOURLY ON FIRE WATCH FORMS. DOCUMENTATION OF FINDINGS WILL BE MADE AVAILABLE TO THE AUTHORITY UPON THEIR REQUEST. IN THE EVENT OF ANY FIRE/SMOKE EMERGENCIES DISCOVERED DURING THE FIRE WATCH, EMERGENCY

NOTIFICATION WILL BE PROVIDED TO THE PREDETERMINED POINT OF CONTACT.

13. OUTAGES WILL NOT BE PERMITTED TO TAKE PLACE FOR THE ENTIRE DURATION OF THE PROJECT. OVERNIGHT OUTAGES WILL NOT BE PERMITTED UNLESS WORK IS BEING DONE DURING THAT TIME PERIOD AND THE FIRE ALARM SYSTEM IS PUT BACK INTO SERVICE WITHIN AN HOUR FROM COMPLETION OF WORK. OUTAGES SHALL BE LIMITED

TO 8 HOURS.

14. THE FIRE ALARM SYSTEMS IS NOT PERMITTED TO HAVE AN OUTAGE FOR MORE THAN AN HOUR BEFORE STARTING WORK. THE FIRE ALARM SYSTEM SHALL BE RESTORED WITHIN AN HOUR OF COMPLETION OF WORK. THE

CONTRACTOR CANNOT LEAVE THE CONSTRUCTION SITE UNPROTECTED.

15. ALL WORK ON THE FIRE ALARM SYSTEM CAN ONLY OCCUR THE FOLLOWING DATES/TIMES WHEN THE BUILDING IS

OCCUPIED:

15.1. MONDAY-FRIDAY: 6:00 PM-6:00 AM.

15.2. WEEKENDS: ANY TIME.

15.3. FEDERAL HOLIDAY: ANY TIME.

16. UNLESS OTHERWISE NOTED, CEILINGS ARE 10' OR LESS. CEILING HEIGHT IN EXCESS OF 10' IS IDENTIFIED WITH

CEILING HEIGHT AFF.

DD - DUCT DETECTOR

DR - DOOR RELEASE

ST - ELEVATOR SHUNT TRIP

PR - PRIMARY ELEVATOR RECALL

SR - SECONDARY ELEVATOR RECALL

FH - FIREMAN'S HAT

WF - WATER FLOW

TS - TAMPER SWITCH

EP - ELEVATOR POWER MONITOR

FACP (E)

N

8'0 16' 1/8"=1'-0"

BASEMENT FLOOR PLAN - DEMOLITION1

MAINTENANCE

SHOP

OFFICES USPSBREAK

ROOM

LOCKER/STORAGE

ROOM

MARINE

RECRUIT

CORRIDOR STAIR 1

CORRIDOR

CORRIDOR

SUPPORT

ENGINEER

PLANT

ENGINEER

MEN'S

TOILET

WOMEN'S

TOILET

NAVY

RECRUIT

TELEPHONE

ROOM BUILDING

NAVY

RECRUIT

CORR.

VEST.

CORRIDOR

STORAGE

MACHINE

ROOM

MACHINE

SHOP

MACHINE

ROOM

US MARSHAL

VAULT

US DISTRICT

COURT VAULT

CONFERENCE

ROOM

POSTAL

EQUIPMENT

CUSTODIAL

SHOP

JANITOR

CORRIDOR

CORRIDOR

CORRIDOR

ELEV. 1

CORRIDOR JANITOR

SUPPLIES

MAINTENANCE

ENGINEER

USPS STORAGE

ROOM CLOSET

COURT STORAGE

AREA

AREAWAYAREAWAY

BOILER

CHIMNEY

FITNESS ROOM

BOILER AND

MECHANICAL ROOM

CRAWL SPACE

AIM

AIM

B

BATT (E)

CONFORMED CONSTRUCTION SET

FI

LE

N

RE

F:

PL

OT

D

AT

E:

4/2

/20

3:

:21 P

M

4.5

FD

1- B1

.D W

G

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

NOTES

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. DEMOLITION DEFINITION: DISCONNECT AND REMOVAL OF ASSOCIATED

CONDUCTORS SHALL CONSIST OF THE REMOVAL OF THE CONDUCTORS

BACK TO THE NEXT EXISTING DEVICE TO REMAIN. NEW CONDUIT AND

CONDUCTORS SHALL BE PROVIDED TO RECONNECT ANY EXISTING TO

REMAIN DEVICES INTERRUPTED BY THE DEMOLITION UNDER THIS

PROJECT.

1. DISCONNECT AND REMOVE FIRE ALARM EQUIPMENT INCLUDING BUT NOT

LIMITED TO NOTIFICATION APPLIANCES, PULL STATIONS, AND SMOKE

DETECTORS.

8'0 16' 1/8"=1'-0"

FIRST FLOOR PLAN - DEMOLITION1

CLOSET

CORRIDOR

CORRIDOR

MAILING

VESTIBULE

CELLBLOCK

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

VESTIBULE

SUPPLY CLOSET

TELEPHONE

VESTIBULE

WOMENS

MENS

JANITOR

COPY ROOM

BREAKROOM

CONFERENCE

SQUAD ROOM

FIT ROOM

MENS LOCKER

WOMENS

LOCKER

WARRANTS PRIVATE OFFICE

ADMINISTRATION

ADMIN OFFICER

ELEVATOR MECH

STORAGE

ELEC.

CLOSET

STORAGE

RECEPTION

BUILDING AND

GROUNDS

TRASH

LOADING DOCK

OFFICE

MARSHAL

PRIVATE OFFICE

TOILET

SECURE

STORAGE

VAULT

INTERVIEW

INTERVIEW

DATA

CELLBLOCK

CONTROL

VEHICLE SALLY

PORT

CORRIDOR

STAIR 1

ELEV 1

STAIR 3

PRISONER

ELEV

OFFICE

TOILET

INTERVIEW

INTERVIEW

SCREENING

EQUIPMENT AREA

WORK ROOM

LUNCH ROOM AND

VENDING AREA

MEN'S LOCKER

ROOM

PROCESSING

EXISTING

ELEV 3 ELEVATOR

VESTIBULE

CORRIDOR

WOMEN'S TOILET VAULT

POST OFFICE /

MAILROOM

SCHEME ROOM

CONFERENCE /

TRAINING

WOMEN'S TLT

MEN'S TOILET

PRIVATE

TOILET

CORRIDOR

F

F

F

B

F

FI

LE

N

RE

F:

PL

OT

D

AT

E:

1/1

7/2

4 2 :18

:30 P

M

4.5

FD

2-

.D W

G

CONFORMED CONSTRUCTION SET

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

NOTES

1. DISCONNECT AND REMOVE FIRE ALARM EQUIPMENT INCLUDING BUT NOT

LIMITED TO NOTIFICATION APPLIANCES, PULL STATIONS, AND SMOKE

DETECTORS.

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. DEMOLITION DEFINITION: DISCONNECT AND REMOVAL OF ASSOCIATED

CONDUCTORS SHALL CONSIST OF THE REMOVAL OF THE CONDUCTORS

BACK TO THE NEXT EXISTING DEVICE TO REMAIN. NEW CONDUIT AND

CONDUCTORS SHALL BE PROVIDED TO RECONNECT ANY EXISTING TO

REMAIN DEVICES INTERRUPTED BY THE DEMOLITION UNDER THIS

PROJECT.

OS

OS

OS

OS OS

N

8'0 16' 1/8"=1'-0"

BASEMENT FLOOR PLAN1

FACP FACP

NAP

AIM

AIM

15 15

S

S

AIM

AIM

AOM

AOM

AOM

AIM

NAP

AIMAIM

AOM

AHU-2

AHU-5

AHU-1

AHU-3

BATT(E)

(E)

JUDGES' EL.

EL 1

OFFICES USPS

BREAK ROOM

MARINE RECRUIT

CORRIDOR

STAIR 1

SUPPORT ENGINEER

PLANT ENGINEER

MEN'S TOILET

WOMEN'S TOILET

NAVY

RECRUIT

NAVY

RECRUIT

CORRIDOR

US MARSHAL

VAULT

US DISTRICT

COURT VAULT

POSTAL EQUIPMENT

CORRIDOR

ELEV 01

JANITOR SUPPLIES

COURT STORAGE

AREA

AREAWAY

AREAWAY

BOILER

CHIMNEY

CRAWL SPACE

MECHANICAL ROOM

STAIR 2

SECURE CORRIDOR

ELECTRICAL ROOM

FITNESS ROOM

CORRIDOR

STORAGE

MAINTENANCE SHOP

CONFERENCE ROOM

CUSTODIAL SHOP

CORRIDOR

EMR

SALLY

PORT

TELEPHONE ROOM

BUILDING

ELEVATOR

EL 04

PRISONER

S S S

S S S

S S S

S

S

ELEV

AOMAOM

AOM

AOM

AIM

TS

WF

TS

WF

DD

DD

WFTS TS

ST

EP

FH

SR

PR

DD

DD

AIM

TS

EMR

PIT

TR

FI

LE

N

RE

F:

PL

OT

D

AT

E:

4/2

/20

3:

:30 P

M

4.5

FA

1- B1

.D W

G

CONFORMED CONSTRUCTION SET

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS

SPECIFICALLY MARKED "EXISTING", "EXIST", OR "(E)".

G3. WHERE CONDUIT PENETRATES PARTITIONS WITH A SPECIFIED STC RATING,

SEAL PENETRATIONS TO MEET STC RATING SPECIFIED. SEE

ARCHITECTURAL PARTITION DETAILS FOR ADDITIONAL INFORMATION.

NOTES

1. PROVIDE FIRE ALARM SYSTEM IN ACCORDANCE WITH NFPA 72 AND P100.

2. PROVIDE ADDRESSABLE FACP WITH VOICE CAPABILITY AND ADDITIONAL

NAP(S) TO SERVE FIRE ALARM NOTIFICATION IN AREAS OF WORK. RETAIN

EXISTING FACP TO SERVE AREAS OUTSIDE SCOPE OF WORK. EXISTING

FACP TO BE MONITORED BY THE NEW FACP.

3. PROVIDE MONITOR MODULES FOR SPRINKLER SYSTEM WATER FLOW AND

TAMPER SWITCHES.

4. NOT USED.

5. PROVIDE CONTROL MODULE FOR AHU SHUTDOWN. PROVIDE DUCT

DETECTOR ON SUPPLY SIDE OF AHU.

6. PROVIDE FOUR (4) CONTROL MODULES FOR ELEVATOR SHUNT TRIP,

PRIMARY RECALL, SECONDARY RECALL, AND FIREMAN'S HAT. PROVIDE

ONE (1) MONITOR MODULE FOR ELEVATOR POWER MONITORING.

8'0 16' 1/8"=1'-0"

FIRST FLOOR PLAN1

F

F

AIM

AIM

S S S

S

S

S S

S S15

15 15 15

15 15

S

SS

S

FIRE ALARM ZONE 1

FA

CP

FATC

LC

D

ELEV

S

S

CLO.

CORR.

MAIN CORRIDOR/

PRE-FUNCTION

101A

SOUND

LOCK

115 EXHIBITS

TRIAL JURY

ROOM

JURY CORRIDOR

MAIN

CORRIDOR

COURTROOM

EQUIP. STORAGE

PRISONER

PROCESSING

SALLY

PORT

145C CORRIDOR

143B

RESTRICTED CORRIDOR

RESTRICTED

CORRIDOR

DISTRICT

COURTROOM

JURY

TLT. RM.

JURY

TLT. RM.

TLT RM

132B

VESTIBULE

132A

ROOM

COPY/

WORKROOM

JUDGE'S

OFFICE

LAW

CLERK

LAW

CLERK

JUDICIAL

ASSISTANT

RECEPTION

BREAK

ROOM

COURT

REPORTER

COURT

REPORTER

CORRIDOR

STAIR 2

120B

STO.

123A

VESTIBULE

STO.

120A

TELECOM

CLOSET

SOUND

LOCK

SALLY

PORT

122C

HOLD.

CELL

122D

RESTR.

CONFERENCE

SCREENING

VESTIBULE

100A

ENTRANCE

LOBBY

EXIT

LOBBY

VACANT

(FUTURE

COURTROOM)

VACANT

(FUTURE JUDGES'

CHAMBERS)

MAIN

LOBBY

VACANT

VACANT (FUTURE

JURY ASSEMBLY) VACANT

(FUTURE

CLERK'S

OFFICE)

MENS

VEHICLE SALLY

PORT

LOADING DOCK

CORRIDOR CONFERENCE WARRANTS PRIVATE OFFICE

OFFICE

COPY ROOM

CORRIDOR

BREAKROOM

MARSHAL

PRIVATE OFFICE ADMINISTRATION

RECEPTION

ADMIN OFFICER

CORRIDOR

SECURE

STORAGE

SQUAD ROOM

TRASH

BUILDING AND

GROUNDS

CORRIDOR

MENS LOCKER

WOMENS LOCKER

FIT ROOM

CORRIDOR

VAULT INTERVIEW INTERVIEW

INTERVIEW

INTERVIEW

STORAGE

ELEVATOR

MECH

STAIR 3

CELLBLOCK

PRISONER

ELEV 03

CL.

STAIR 1

ELEV 01

PRISONER

ELEVATOR

122B

EL 04

15 15

F

WF

TS

S S

S

16'-7"AFF

16'-7"AFF

16'-7"AFF

16'-7"AFF

16'-7"AFF

15'-7"AFF

15'-7"AFF

14'AFF

11'-8"AFF

13'-2"AFF (TYP)

TR

TR

TR

TR

TR

TR

TR

TR

TR

15'-7"AFF

ATTORN./WIT.

ATTORN./WIT.

ROOM 2

ROOM 1

FI

LE

N

RE

F:

PL

OT

D

AT

E:

4/2

/20

3:

:19 P

M

4.5

FA

2-

.D W

G

CONFORMED CONSTRUCTION SET

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS

SPECIFICALLY MARKED "EXISTING", "EXIST", OR "(E)".

G3. WHERE CONDUIT PENETRATES PARTITIONS WITH A SPECIFIED STC RATING,

SEAL PENETRATIONS TO MEET STC RATING SPECIFIED. SEE

ARCHITECTURAL PARTITION DETAILS FOR ADDITIONAL INFORMATION.

NOTES

1. PROVIDE FIRE ALARM SYSTEM IN ACCORDANCE WITH NFPA 72 AND P100.

2. PROVIDE MONITOR MODULES FOR SPRINKLER ZONE CONTROL ASSEMBLY.

3. PROVIDE FIRE ALARM TERMINAL CABINET FOR ADDITION OF FIRST FLOOR

FIRE ALARM DEVICES.

4. PROVIDE ELECTRONIC WATER FLOW ALARM BELL.

5. PROVIDE LCD ANNUNCIATOR PANEL IN COMMON AREA NEAR MAIN LOBBY.

6. DETENTION AREA FACP WILL BE CONSTANTLY MONITORED FOR

NOTIFICATION / EVACUATION. PROVIDE TAMPER-RESISTANT STROBES IN

PRISONER SPACES.

7. PROVIDE A DEDICATED FACP FOR DETENTION & CORRECTIONAL AREA.

8. NOT USED.

S

AIM AOM

N

8'0 16' 1/8"=1'-0"

SECOND FLOOR PLAN1

AHU-6

AIM

MECHANICAL PLATFORM

MECHANICAL PENTHOUSE

JURY ROOM

IT OFFICE

CORRIDOR

CORRIDOR

TLT RM

WOMEN'S TLT

MEN'S TLT

CORRIDOR

TLT RM TLT RM CLOSET

CORRIDOR

MAGISTRATE MAGISTRATE ATTORNEY/

WITNESS

CONFERENCE

CELL

CELL

CORR

CSO OFFICE CONFERENCE ROOM CORRIDOR

OFFICE

CORR

CONFERENCE ROOM

JUDICIAL ASSISTANT

OFFICE

JUDGE'S

CHAMBERS

COURTROOM COURTS OFFICE SPACE

DEPUTY

CLERK

COURTROOM

ATTORNEY

CONFERENCE

ROOM

RECEPTION

LOBBY

CORRIDOR

COURTROOM

BELOW

COURTROOM

BELOW

STAIR 1

STAIR 2

CL.

PRISONER

ELEV

WF

TS

DDS

CONFORMED CONSTRUCTION SET

FI

LE

N

RE

F:

PL

OT

D

AT

E:

4/2

/20

3:

:01 P

M

4.5

FA

3-

.D W

G

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS

SPECIFICALLY MARKED "EXISTING", "EXIST", OR "(E)".

G3. WHERE CONDUIT PENETRATES PARTITIONS WITH A SPECIFIED STC RATING,

SEAL PENETRATIONS TO MEET STC RATING SPECIFIED. SEE

ARCHITECTURAL PARTITION DETAILS FOR ADDITIONAL INFORMATION.

NOTES

1. PROVIDE FIRE ALARM SYSTEM IN ACCORDANCE WITH NFPA 72 AND P100.

2. PROVIDE MONITOR MODULES FOR SPRINKLER SYSTEM WATER FLOW AND

TAMPER SWITCHES.

3. PROVIDE CONTROL MODULE FOR AHU SHUTDOWN.

1/8"=1'-0"

THIRD FLOOR PLAN1

MEN'S TLT

WOMEN'S TLT

TLT RM

CORRIDOR

CORRIDOR

CORRIDOR

VESTIBULE

CORRIDOR

CORRIDOR

UPPER PART OF

COURTROOM OPEN

TO BELOW

UPPER PART OF

LIBRARY OPEN TO

BELOW

UPPER PART

OF OFFICES

OPEN TO

BELOW

UPPER PART

OF OFFICES

OPEN TO

BELOW

JANITOR

CLOSET

STAIR 4

LAW CLERK

TLT RM

CLOSET

CLOSET

TLT RM

TLT RM BREAK ROOM

CLOSET

JURY

CONFERENCE

ROOM

STAIR 3

STAIR 1

ELEV 1

CHIEF DEPUTY CONFERENCE ROOM

BREAK ROOM

WORK/COPY AREA

CLERKS OFFICE

OFFICE

US ATTORNEY

OFFICE

OFFICE/

CONFERENCE ROOM

OFFICE/PANTRY

OFFICE

COURTROOM

CLOSET

EXISTING FIRST

FLOOR ROOF

BEYOND

EXISTING MAILING

PLATFORM ROOF

BEYOND

STAIR 2 ROOF

NEW MECHANICAL

PENTHOUSE ROOF

FIRST FLOOR ROOF

BELOW

VEST.

FI

LE

N

RE

F:

PL

OT

D

AT

E:

4/2

/20

3:

:10 P

M

4.5

FA

4-

.D W

G

CONFORMED CONSTRUCTION SET

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS

SPECIFICALLY MARKED "EXISTING", "EXIST", OR "(E)".

G3. WHERE CONDUIT PENETRATES PARTITIONS WITH A SPECIFIED STC RATING,

SEAL PENETRATIONS TO MEET STC RATING SPECIFIED. SEE

ARCHITECTURAL PARTITION DETAILS FOR ADDITIONAL INFORMATION.

N

RE

F:

PL

OT

D

AT

E:

4/2

/20

3:

:18 P

M

4.5

FA

1.D W

G

CONFORMED CONSTRUCTION SET

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

ANNUNCIATION NOTIFICATION CONTROL

AL

AR

M

AN

NU

NC

IA

TI

ON

A

T

FA

CP

/F

AA

P

AN

D

SE

ND

S

TA

TU

S

TO

CE

NT

RA

L S

TA

TI

ON

SU

PE

R

VI

SO

R

Y

AN

N U

N C

IA

TI

O N

A T

FA

C

P/

FA

AP

AN

D S

EN

D

S

TA

TU

S

TO

C

EN

TR

AL

S

TA

TI

O N

TR

O

U

BL

E

AN

N U

N C

IA

TI

O N

A T

FA

C

P/

FA

AP

AN

D S

EN

D

S

TA

TU

S

TO

C

EN

TR

AL

S

TA

TI

O N

AC

TI

VA

TE

V

IS

U

AL

A N

D A

U D

IB

LE

N O

TI

FI

C

AT

IO

N

G

EN

ER

AL

E

VA

C

U

AT

IO

N

FI

R

ST

L

EV

EL

E

LE

VA

TO

R R

EC

AL

L

SE

C O

N D

L

EV

EL

E

LE

VA

TO

R

R

EC

AL

L

FI

R

E H

AT

L

IG

H

T

ST

EA

D

Y O

N

EL

EV

AT

O

R P

O W

ER

S

H U

N T

TR

IP

(E )N

AC

B

E- 3E

BASEMENT

FIRST FLOOR

(E)

FACP

FIREFINDER

SECOND FLOOR

THIRD FLOOR

ATTIC

NO SCALE

FIRE ALARM RISER DIAGRAM1 FIRE ALARM MATRIX

MANUAL PULL STATION

FACP

MAINTENANCE ENGINEER ROOM

AIM AIM

WFTS

(E )S

LC

B

E- 3E

(E)WIRE

TROUGH(E)NAC BE

(E)SLC BE

EXISTING APPLIANCES

EXISTING DEVICES

CTRL

CT

RL

SL

C

B-

AM

P

B-

AN

N

WIRE

TROUGH

SPD

PROVIDE DEDICATED 120V 20A CIRCUIT

NAP

SPD

PROVIDE DEDICATED 120V 20A CIRCUIT

NAC B

AMP B

SLC B

NAC 1

AOM

FATCCTRLFACP

CELLBLOCK CONTROL

SPD

PROVIDE DEDICATED

120V 20A CIRCUIT

BASEMENT

(E)NAC 1E

(E)SLC 1E

EXISTING APPLIANCES

EXISTING DEVICES

(E)NAC 2E

(E)SLC 2E

EXISTING APPLIANCES

EXISTING DEVICES

(E)NAC 3E

(E)SLC 3E

EXISTING APPLIANCES

EXISTING DEVICES

LCDANN

AMP 1

SLC 1

AIM AIM

WFTS

F

FIRST FLOOR

TELECOM CLOSET 124

PROVIDE CLASS A WIRING AS

REQUIRED FOR NEW CIRCUIT

S

SECOND FLOOR

THIRD FLOOR

ROOF

ATTIC

EL

EC

R O

O M

P O

W

ER

S H

U N

T

TR

IP

SH

U

T D

O W

N A

SS

O

C

IA

TE

D

A H

U

AOM AOM

AOM

DH

NAP

SPD

PROVIDE

DEDICATED 120V

20A CIRCUIT

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS

SPECIFICALLY MARKED "EXISTING", "EXIST", OR "(E)".

NOTES

1. PROVIDE FIRE ALARM SYSTEM IN ACCORDANCE WITH NFPA 72 AND P100.

REFER TO FLOOR PLANS FOR LOCATIONS OF INDIVIDUAL EQUIPMENT.

2. PROVIDE INFRASTRUCTURE AS NECESSARY FOR EXTENSION OF SYSTEM

TO REMAINDER OF THE BUILDING IN FUTURE PHASES.

SMOKE DETECTOR

SMOKE DETECTOR - ELEVATOR LOBBY - FIRST FLOOR

SMOKE DETECTOR - ELEVATOR LOBBY - ALL BUT FIRST FLOOR

SMOKE DETECTOR - ELEVATOR MACHINE ROOM

DUCT SMOKE DETECTOR

WATER FLOW SWITCH

WATER FLOW SWITCH - E.M.R. SPRINKLER ZONE

WATER FLOW SWITCH - ELECTRICAL ROOM SPRINKLER ZONE

HEAT DETECTOR - ELEVATOR MACHINE ROOM

TAMPER SWITCH

FACP POWER FAILURE

LOW BATTERY

OPEN CIRCUIT

GROUND FAULT

MECHANICAL

PENTHOUSE 203

AM

P

B

AMP B

NA

C

AIM AIM

S

S

AOM

WFTS AHU

AMP 1

AM

P

NA

C

NAC 1

NAC 1

AHU ELEV

AIM

ELEV

MONITOR

NAP

FI

R

E H

AT

L

IG

H

T

FL

AS

H

IN

G

HEAT DETECTOR - ELEVATOR PIT

N

RE

F:

PL

OT

D

AT

E:

1/1

7/2

4 2 :19

:08 P

M

4.5

FX

1.D W

G

CONFORMED CONSTRUCTION SET

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

ABBREVIATIONS

A AMPERES

AC ABOVE CEILING

AFF ABOVE FINISHED FLOOR

AHJ AUTHORITY HAVING JURISDICTION

ATC ACOUSTIC TILE CEILING

AWG AMERICAN WIRE GAUGE

C/CL CEILING LEVEL

D DRAIN

DN DOWN

ELEV. ELEVATOR

EMT ELECTRICAL METALLIC TUBING

ETR EXISTING TO REMAIN

(E) EXISTING

F FIRE LINE

FDC FIRE DEPARTMENT CONNECTION

FH FIRE HYDRANT

FHV 2-1/2" FIRE HOSE VALVE

N.I.C. NOT IN CONTRACT

SP SPRINKLER PIPING

TYP. TYPICAL

SYMBOLS

LIGHT HAZARD

DISCHARGE DENSITY 0.1 GPM/SF

REMOTE AREA 1500SF

ORDINARY HAZARD GROUP 1

DISCHARGE DENSITY 0.15 GPM/SF

REMOTE AREA 1500SF

RISER VALVE

CHECK VALVE

WATER FLOW SWITCH

SPRINKLER PIPE

MODIFICATION OF THE SPRINKLER SYSTEM

IN THIS AREA IS NOT IN CONTRACT (N.I.C.)

TAMPER SWITCH

SPRINKLER

ZCA SPRINKLER ZONE CONTROL ASSEMBLY

WF

TS

AREA OF WORK

INSPECTORS TEST CONNECTION

GENERAL SYMBOLS

FA101

N

8'0 1/8"=1'-0"

UNIQUE PLAN OR

DETAIL NUMBER

ON THIS DRAWING NORTH ARROW

NAME OF PLAN OR DETAIL

ALL DRAWINGS WHERE

THIS DETAIL IS

REFERENCED FROM

GRAPHIC SCALE OF

THIS PLAN OR DETAIL

SECTION IDENTIFICATION

INDICATES DIRECTION

OF CUTTING PLANE

NUMBER INDICATES SECTION

SHEET NUMBER WHERE

SECTION IS DRAWN

2-PART REFERENCE DETAIL IDENTIFICATION:

SHEET NUMBER WHERE

DETAIL/SECTION IS DRAWN

NUMBER INDICATES

DETAIL/SECTION

FLOOR PLAN

FA101,FA1022

FLOOR PLAN AND DETAIL TITLES:

FA101

N

(E)

REVISION CLOUD WITH REVISION

NUMBER DESIGNATION

BREAKLINE

MATCHLINE DESIGNATIONM A T C H L I N E A-A

EXISTING

POINT OF CONNECTION TO EXISTING

POINT OF TERMINATION OF REMOVAL

NOTE NUMBER#

ARROW INDICATES TRUE NORTH

AND/OR PROJECT NORTH.

ROOM NUMBER

COLUMN LINE NUMBER

NORTH ARROW

SPRINKLER ZONE

F

WATER FLOW TEST REPORTWATER FLOW TEST MAP

CLARKSBURG COURTHOUSE

HYDRANT 27-149-A

HYDRANT 27-451-B

SPRINKLER

ELECTRONIC ALARM BELL

FIRE SUPPRESSION REQUIREMENTS

1. MODIFY THE EXISTING WET-PIPE SPRINKLER SYSTEM AND PROVIDE DESIGN, EQUIPMENT, INSTALLATION, AND

TESTING TO MAKE A COMPLETE WET PIPE SPRINKLER SYSTEM WITH INTEGRATED CLASS 1 WET-PIPE STANDPIPE.

DESIGN AND INSTALL PER 2018 EDITION OF P100 FIRE PROTECTION FOR FACILITIES, THE 2019 EDITION OF NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, AND THE 2019 EDITION OF NFPA 14, STANDARD FOR

THE INSTALLATION OF STANDPIPES.

2. UNLESS OTHERWISE NOTED, PROVIDE SPRINKLER SYSTEM DESIGN IN ACCORDANCE WITH LIGHT HAZARD CRITERIA.

3. CONTACT THE CLARKSBURG WEST VIRGINIA WATER AUTHORITY AT 304-623-3711 TO OBTAIN FIRE HYDRANT WATER

FLOW TEST DATA.

4. PROVIDE CONCEALED QUICK RESPONSE WHITE SPRINKLERS IN AREAS WITH FINISHED CEILINGS. PROVIDE QUICK RESPONSE BRASS UPRIGHT SPRINKLERS IN AREAS WITHOUT FINISHED CEILINGS. PROVIDE A MINIMUM SPRINKLER

TEMPERATURE OF 155 FAHRENHEIT OR HIGHER FOR ORDINARY TEMPERATURE SPRINKLERS.

5. PROVIDE SPRINKLERS HEADS WITH LISTED GUARDS WITHIN ELEVATOR MACHINE ROOM, ELEVATOR PITS, AND

ELECTRICAL ROOMS AS REQUIRED BY P100.

6. PROVIDE SPRINKLERS IN CENTER OF ACOUSTIC CEILING TILES.

7. PROVIDE BLACK STEEL SPRINKLER PIPE. PIPE 2-INCH AND BELOW MUST BE SCHEDULE 40, PIPE 2.5-INCHES AND

GREATER MUST BE MINIMUM SCHEDULE 10.

8. PAINT SPRINKLER PIPE RED. PROVIDE WHITE STENCILING INDICATING SYSTEM AND PIPE DIAMETER.

9. DO NOT PROVIDE SPRINKLER VALVES ABOVE HARD CEILINGS. DO NOT PROVIDE SPRINKLERS BELOW RAISED FLOOR. PROVIDE IDENTIFICATION SIGNAGE FOR ALL VALVES LOCATED ABOVE SUSPENDED CEILINGS.

10. FIRE SUPPRESSION SYSTEMS MUST REMAIN ACTIVE OUTSIDE THE AREA OF WORK.

11. ALL REQUIRED OUTAGES OF THE SPRINKLER SYSTEM SHALL BE COORDINATED THROUGH THE CONTRACTING OFFICER NOT LESS THAN 15 WORKING DAYS IN ADVANCE. THE GOVERNMENT WILL PROVIDE THE REQUESTED OUTAGE AND ASSOCIATED RESTORATION OF THE SPRINKLER SYSTEM. THE GOVERNMENT WILL IDENTIFY TO THE CONTRACTOR WHAT PIPING/EQUIPMENT HAVE BEEN TAKEN OUT OF SERVICE ONCE THE OUTAGE HAS BEEN MADE.

THE GOVERNMENT WILL NOT DRAIN OR REFILL SPRINKLER PIPING AS PART OF AN OUTAGE. THIS WORK SHALL BE PERFORMED BY THE CONTRACTOR. OUTAGES DO NOT INCLUDE CONNECTION OF NEW WORK TO EXISTING

SPRINKLER PIPING.

12. AN EXCLUSIVE GOVERNMENT CONTRACTOR/VENDOR RESPONSIBLE FOR MAINTAINING GOVERNMENT FIRE PROTECTION SYSTEMS SHALL BE OBTAINED FOR TIE IN OF NEW WORK AND/OR MODIFICATION OF OPERATING, EXISTING SPRINKLER SYSTEMS, AT CONTRACTORS COST.

13. A FIRE WATCH, AT CONTRACTOR'S COST, WILL BE CONDUCTED CONTINUOUSLY THROUGHOUT THE DURATION OF THE OUTAGE IN ALL AREAS AFFECTED BY THE OUTAGE. FINDINGS/COMMENTS WILL BE DOCUMENTED HOURLY ON FIRE WATCH FORMS. DOCUMENTATION OF FINDINGS WILL BE MADE AVAILABLE TO THE AUTHORITY UPON THEIR REQUEST. IN THE EVENT OF ANY FIRE/SMOKE EMERGENCIES DISCOVERED DURING THE FIRE WATCH, EMERGENCY

NOTIFICATION WILL BE PROVIDED TO THE PREDETERMINED POINT OF CONTACT.

14. OUTAGES WILL NOT BE PERMITTED TO TAKE PLACE FOR THE ENTIRE DURATION OF THE PROJECT.

15. OVERNIGHT OUTAGES WILL NOT BE PERMITTED UNLESS WORK IS BEING DONE DURING THAT TIME PERIOD AND THE SPRINKLER SYSTEM IS PUT BACK INTO SERVICE WITHIN AN HOUR FROM COMPLETION OF WORK. OUTAGES SHALL

BE LIMITED TO 8 HOURS INCLUDING TIME FOR DRAINING AND REFILLING.

16. THE SPRINKLER SYSTEM IS NOT PERMITTED TO HAVE AN OUTAGE FOR MORE THAN AN HOUR BEFORE STARTING WORK. THE SPRINKLER SYSTEM SHALL BE RESTORED WITHIN AN HOUR OF COMPLETION OF WORK. THE CONTRACTOR CANNOT LEAVE THE CONSTRUCTION SITE UNPROTECTED. THE SPRINKLER SYSTEM SHALL BE FILLED

WITHIN AN HOUR OF COMPLETION OF WORK

17. ALL WORK ON THE FIRE SPRINKLER SYSTEM CAN ONLY OCCUR THE FOLLOWING DATES/TIMES WHEN THE BUILDING

IS OCCUPIED:

17.1. MONDAY-FRIDAY: 6:00 PM-6:00 AM.

17.2. WEEKENDS: ANY TIME.

17.3. FEDERAL HOLIDAY: ANY TIME.

18. THE FIRE DEPARTMENT CONNECTION MUST BE A MAXIMUM OF 100 FEET FROM A FIRE HYDRANT IN ACCORDANCE

WITH NFPA 14-2019 EDITION SECTION 6.4.5.4.

7/8/2020

ORDINARY HAZARD GROUP 1

DISCHARGE DENSITY 0.15 GPM/SF

REMOTE AREA 1500SF

OH2

UNLESS

OTHERWISE

NOTED

DOUBLE CHECK BACKFLOW PREVENTERDBC

SPRINKLER ZONE CONTROL ASSEMBLY

INCLUDING WATERFLOW SWITCH, GATE

VALVE AND TAMPER SWITCH, AND

INSPECTOR'S TEST CONNECTION

ZCA

OH1

SPRINKLER ARMOVER

1/8"=1'-0"

BASEMENT FLOOR PLAN - DEMOLITION1

DBC

(E)6"F INCOMING

WATER SUPPLY

6"F

3"F

WF 2"F UP

3"F UP

3"F

MAINTENANCE

SHOP

CORRIDOR

STORAGE

MACHINE

ROOM

MACHINE

ROOM

CONFERENCE

ROOM

POSTAL

EQUIPMENT

CUSTODIAL

SHOP

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

JANITOR

SUPPLIES MAINTENANCE

ENGINEER

USPS STORAGE

ROOM CLOSET

COURT STORAGE

AREA

AREAWAYAREAWAY

BOILER

CHIMNEY

FITNESS ROOM

BOILER AND

MECHANICAL ROOM

(E)6" COLT

300-BF DCDA

FX501

(E)1-1/4"F(E)1"F(E)1"F

(E)1-1/4"F(E)1"F(E)1"F

(E)1"F

(E)1"F

(E )1

"F

2"F 2"F

(E )2

"F 2-

1/2 "F

1"F1"F

1"F1"F

(E)1"F(E)1"F

(E)1"F(E)1"F

(E)

3"F

(E)3"F

(E)

(E)

(E)2-1/2"F UP

(E)3"F

(E )3

"F (E

)3 "F

2-1/2"F

2-1/2"F

2-1/2"F

3" F

2-1/2"F

FI

LE

N

RE

F:

PL

OT

D

AT

E:

1/1

7/2

4 2 :19

:11 P

M

4.5

FD

1- B1

.D W

G

CONFORMED CONSTRUCTION SET

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

NOTES

1. DISCONNECT AND REMOVE 6-INCH RISER TO FIRST FLOOR. CAP PIPE

BELOW FIRST FLOOR.

2. DISCONNECT AND REMOVE 4-INCH RISER TO FDC. CAP PIPE BELOW

FIRST FLOOR.

3. DISCONNECT AND REMOVE ALL SPRINKLER PIPE, FITTINGS,

SUPPORT, AND SPRINKLER HEADS BETWEEN POINTS INDICATED.

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. EQUIPMENT INDICATED AS (E) IS EXISTING TO REMAIN.

1/8"=1'-0"

FIRST FLOOR PLAN - DEMOLITION1

6"F FROM BASEMENT

1-1/4"F

1-1/4"F

1-1/4"F

1"F

1" F

1- 1/2

"F 2"

F 1-

1/2 "F

2" F

2" F

2" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

2" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

2" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

2" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

2" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

2" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

2" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

2" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

2" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

1" F

1" F

1" F

2" F

1- 1/2

"F

1- 1/2

"F

1- 1/2

"F

1" F

1- 1/4

"F

2" F

1- 1/2

"F

1"F

6" F

6" F

6"F 6"F6"F5"F5"F5"F5"F4"F4"F3-1/2"F3-1/2"F3"F3"F2-1/2"F 4"F 3-1/2"F 3-1/2"F 3"F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

1- 1/4

"F 1-

1/2 "F

1" F

1" F

2" F

2" F

2" F

1- 1/2

"F 1-

1/2 "F

2" F

2" F

2" F

1- 1/4

"F 2" F

2" F

2" F

2" F

1- 1/2

"F

1- 1/2

"F

1- 1/2

"F

1- 1/2

"F

1- 1/2

"F

1- 1/4

"F

1- 1/4

"F

1- 1/2

"F 1-

1/4 "F

1" F

1" F

1" F

1" F

1" F

1" F

3" F

2-1/2"F 2"F

2" F

2" F

2" F

1"F

1- 1/4

"F

1- 1/2

"F

1"F

1"F

1"F

1"F

1" F1"

F 1"

F

1"F 1"F

1- 1/2

"F 1-

1/2 "F

1.5"F1.5"F

2" F

1- 1/2

"F 1-

1/2 "F

1-1/4"F1"F 1"F

(E )1

"F

(E )1

"F

(E )1

"F

(E )1

"F

(E )2

"F

(E)1-1/2"F

(E )2

"F

(E )2

"F

(E )2

"F

(E )2

"F

(E )2

"F

(E )2

"F

(E )2

"F

(E)1-1/2"F (E)1-1/2"F

2 (TYP)

(E) (E) (E) (E)

SPRINKLER DRAIN

SPRINKLER DRAIN

FI

LE

N

RE

F:

PL

OT

D

AT

E:

1/1

7/2

4 2 :19

:14 P

M

4.5

FD

2-

.D W

G

CONFORMED CONSTRUCTION SET

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

NOTES

1. DISCONNECT AND REMOVE ALL FIRE SUPPRESSION PIPE, FITTINGS,

SUPPORTS, AND SPRINKLERS INSIDE AREA OF WORK.

2. DISCONNECT AND CAP PIPE SERVING AREAS OUTSIDE SCOPE OF WORK AT

LOCATION INDICATED.

3. DISCONNECT AND REMOVE EXISTING FDC AND ASSOCIATED PIPE/FITTINGS

BACK TO BASEMENT LEVEL. DISCONNECT AND REMOVE EXISTING WATER

MOTOR GONG.

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

6"F

FX401

1-1/2"F

N

8'0 16' 1/8"=1'-0"

BASEMENT FLOOR PLAN - SPRINKLER1

OFFICES USPS

BREAK ROOM

MARINE RECRUIT

CORRIDOR

STAIR 1

SUPPORT ENGINEER

PLANT ENGINEER

MEN'S TOILET

WOMEN'S TOILET

NAVY

RECRUIT

NAVY

RECRUIT

CORRIDOR

US MARSHAL

VAULT

US DISTRICT

COURT VAULT

CORRIDOR

ELEV 01

JANITOR SUPPLIES

COURT STORAGE

AREA

AREAWAY

AREAWAY

BOILER

CHIMNEY

CRAWL SPACE

MECHANICAL ROOM

STAIR 2

SECURE CORRIDOR

ELECTRICAL ROOM

FITNESS ROOM

CORRIDOR

STORAGE

MAINTENANCE ENGINEER

CONFERENCE ROOM

CUSTODIAL SHOP

CORRIDOR

EMR SALLY

PORT

TELEPHONE ROOM

BUILDING

ELEVATOR

EL 04

PRISONER

USPS STORAGE

ROOM CLOSET

(E)

(E)3"F

(E)

ZC

A

4" F

1-1/2"F 1"F

MAINTENANCE

SHOP

MACHINE

ROOM

BOILER

CHIMNEY

(E)1"F(E)1"F

(E)1"F

(E)1"F

(E )1

"F

(E)

POSTAL

EQUIPMENT(E

)2 "F

(E)1"F(E)1"F

(E)1"F(E)1"F

(E)1-1/4"F

(E)1"F

3"F

(E)3"F

OH2

OH2

OH2

OH2

(E)2-1/2"F UP

4" F

WF

OH1

OH1

OH1

2- 1/2

"F

4" F

4"F

4" F

WF

(E)2-1/2"F UP

4"F

4" F

2-1/2"F

2- 1/2

"F 2-

1/2 "F

2-1/2"F

2- 1/2

"F

2- 1/2

"F

2-1/2"F

4"F

2-1/2"F

2-1/2"F 4"F

TS

TS

ZC

A TS

WF

OH2

OH1

OH1

OH2 ELEV.

EMR

(E)1"F(E)1"F

1 1

FI

LE

N

RE

F:

PL

OT

D

AT

E:

4/2

/20

3:

:28 P

M

4.5

FX

1- B1

.D W

G

CONFORMED CONSTRUCTION SET

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS

SPECIFICALLY MARKED "EXISTING", "EXIST", OR "(E)".

G3. WHERE PIPING PENETRATES PARTITIONS WITH A SPECIFIED STC RATING,

SEAL PENETRATIONS TO MEET STC RATING SPECIFIED. SEE

ARCHITECTURAL PARTITION DETAILS FOR ADDITIONAL INFORMATION.

NOTES

1. PROVIDE SPRINKLER COVERAGE THROUGHOUT SPACE IN ACCORDANCE

WITH NFPA 13 AND P100.

2. PROVIDE 6 INCH PIPE UP TO FIRST FLOOR.

3. PROVIDE ELEVATOR PIT SIDEWALL SPRINKLER WITH LISTED GUARD. SEE

FX401 FOR LOCATION OF ISOLATION VALVE. SPRINKLERS MUST BE

LOCATED BELOW ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ASME

17.1. SPRINKLERS MUST BE INSTALLED MORE THAN 2 FEET ABOVE THE

FLOOR OF THE PIT PER NFPA 13.

4. NOT USED.

5. PROVIDE BASEMENT ZONE CONTROL ASSEMBLY.

6. PROVIDE 4 INCH PIPE UP TO EXTERIOR FREE STANDING FIRE DEPARTMENT

CONNECTION.

7. NOT USED.

8. NOT USED.

9. PROVIDE ISOLATION VALVE, TAMPER SWITCH, AND WATER FLOW SWITCH

FOR STANDPIPE CONNECTION SPRINKLER ISOLATION VALVE.

DISTRICT

COURTROOM

2-1/2" F

N

8'0 16' 1/8"=1'-0"

FIRST FLOOR PLAN - SPRINKLER1

ZCA

6" F

SPRINKLER ZONE 1

(E )1

"F

(E )1

"F

(E )1

"F

(E )1

"F

(E )2

"F

(E )2

"F

(E )2

"F

(E )2

"F

(E )2

"F

(E )2

"F

(E )2

"F

(E )2

"F

(TYP)

(E)1-1/2"F

(E)1-1/2"F (E)1-1/2"F

(E) (E) (E) (E)

4" F

4" F

4" F

3" F

3" F

3" F

3" F

3" F3" F3" F3" F3" F3" F

3" F

CLO.

CORR.

MAIN CORRIDOR/

PRE-FUNCTION

101A

SOUND

LOCK

115 EXHIBITS

TRIAL JURY

ROOM

JURY CORRIDOR

MAIN

CORRIDOR

COURTROOM

EQUIP. STORAGE

PRISONER

PROCESSING

SALLY

PORT

145C

CORRIDOR

143B

RESTRICTED

CORRIDOR

JURY

TLT. RM.

JURY

TLT. RM.

TLT RM

132B

VESTIBULE

132A

ROOM

COPY/

WORKROOM

JUDGE'S

OFFICE

LAW

CLERK

LAW

CLERK

JUDICIAL

ASSISTANT

RECEPTION

BREAK

ROOM

128 COURT

REPORTER

COURT

REPORTER

CORRIDOR

STAIR 2

120B

STO.

123A

VESTIBULE

STO.

120A

TELECOM

CLOSET

SOUND

LOCK

SALLY

PORT

122C

HOLD.

CELL

122D

RESTR.

CONFERENCE

SCREENING

VESTIBULE

100A

ENTRANCE

LOBBY

EXIT

LOBBY

VACANT

(FUTURE

COURTROOM)

VACANT

(FUTURE

JUDGES'

CHAMBERS)

MAIN

LOBBY

VACANT

VACANT

(FUTURE

JURY

ASSEMBLY)

VACANT

(FUTURE

CLERK'S

OFFICE)

LOADING DOCK

TRASH

BUILDING AND

GROUNDS

CELLBLOCK

STAIR 1

ELEV 01

PRISONER

ELEVATOR

122B

EL 04

OH1

OH2OH2

OH2

OH2

OH2

OH2

ATTORN./WIT.

ROOM 1

ATTORN./WIT.

ROOM 2

OH2

OH2

OH2

CONTROL ROOM

2-1/2" F

2- 1/2

"F

TS

WF

1-1/4"F 2-1/2" F

1-1/2" F1-1/4" F 1-1/2" F

1-1/4" F

(TYP)

1-1/4" F

(TYP)

1- 1/4

" F

1-1/4" F

(TYP)

1-1/4" F

(TYP)

1-1/4" F

(TYP)

1- 1/4

" F 1-

1/4 " F

2-1/2" F

2-1/2" F 2-1/2" F 2-1/2" F2-1/2" F

2-1/2" F 2-1/2" F 2-1/2" F 2-1/2" F

1" F

OH2

OH2

2-1/2" F

FI

LE

N

RE

F:

PL

OT

D

AT

E:

4/2

/20

3:

:38 P

M

4.5

FX

2-

.D W

G

CONFORMED CONSTRUCTION SET

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS

SPECIFICALLY MARKED "EXISTING", "EXIST", OR "(E)".

G3. WHERE PIPING PENETRATES PARTITIONS WITH A SPECIFIED STC RATING,

SEAL PENETRATIONS TO MEET STC RATING SPECIFIED. SEE

ARCHITECTURAL PARTITION DETAILS FOR ADDITIONAL INFORMATION.

NOTES

1. PROVIDE SPRINKLER COVERAGE THROUGHOUT SPACE PER NFPA 13.

2. PROVIDE 6 INCH ZONE CONTROL ASSEMBLY TO SERVE FIRST FLOOR AREA

OF WORK. PROVIDE BUTTERFLY VALVE WITH TAMPER SWITCH, CHECK

VALVE, PRESSURE GAUGES, INSPECTORS TEST CONNECTION, AND WATER

FLOW SWITCH.

3. CONNECT SPRINKLER SYSTEM TO EXISTING BRANCHLINE SERVING AREA

OUTSIDE SCOPE OF WORK.

4. PROVIDE FREE-STANDING FIRE DEPARTMENT CONNECTION.

5. PROVIDE UPRIGHT SPRINKLERS TO TEMPORARILY PROTECT FUTURE PHASE

SPACE.

6. PROVIDE 6 INCH PIPE UP FROM BASEMENT.

7. PROVIDE INTERMEDIATE TEMPERATURE SIDEWALL HEADS TO PROTECT

CLERESTORY. ROUTE BRANCH LINE ABOVE WINDOWS.

NOTES

8. NOT USED.

9. PROVIDE 2 INCH PIPE UP TO MECHANICAL PENTHOUSE. REFER TO

SHEET FX103 FOR CONTINUATION.

10. PROVIDE INSTITUTIONAL SPRINKLER HEADS FOR DETENTION AND

CORRECTIONAL AREA.

1/8"=1'-0"

SECOND FLOOR PLAN1

ZCA

2"F2"F

2" F

MECHANICAL PLATFORM

MECHANICAL PENTHOUSE

JURY ROOM

IT OFFICE

CORRIDOR

CORRIDOR

TLT RM

WOMEN'S TLT

MEN'S TLT

CORRIDOR

TLT RM TLT RM CLOSET

CORRIDOR

MAGISTRATE MAGISTRATE ATTORNEY/

WITNESS

CONFERENCE

CELL

CELL

CORR

CSO OFFICE CONFERENCE ROOM CORRIDOR

OFFICE

CORR

CONFERENCE ROOM

JUDICIAL ASSISTANT

OFFICE

JUDGE'S

CHAMBERS

COURTROOM COURTS OFFICE SPACE

DEPUTY

CLERK

COURTROOM

ATTORNEY

CONFERENCE

ROOM

RECEPTION

LOBBY

CORRIDOR

COURTROOM

BELOW

COURTROOM

BELOW

STAIR 1

STAIR 2

CL.

PRISONER

ELEV

BREAK ROOM

VAULT

OFFICE

(E)

(E)

OH1

TS

WF

CONFORMED CONSTRUCTION SET

FI

LE

N

RE

F:

PL

OT

D

AT

E:

4/2

/20

3:

:47 P

M

4.5

FX

3-

.D W

G

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS

SPECIFICALLY MARKED "EXISTING", "EXIST", OR "(E)".

G3. WHERE PIPING PENETRATES PARTITIONS WITH A SPECIFIED STC RATING,

SEAL PENETRATIONS TO MEET STC RATING SPECIFIED. SEE

ARCHITECTURAL PARTITION DETAILS FOR ADDITIONAL INFORMATION.

NOTES

1. PROVIDE SPRINKLER COVERAGE THROUGHOUT SPACE IN ACCORDANCE

WITH NFPA 13 AND P100.

2. NOT USED.

3. PROVIDE 2 INCH PIPE FROM 1ST FLOOR AND DEDICATED ZONE CONTROL

ASSEMBLY TO SERVE MECHANICAL PENTHOUSE SPRINKLERS.

1/8"=1'-0"

THIRD FLOOR PLAN1

MEN'S TLT

WOMEN'S TLT

TLT RM

CORRIDOR

CORRIDOR

CORRIDOR

VESTIBULE CORRIDOR

CORRIDOR

UPPER PART

OF

COURTROOM

OPEN TO

BELOW

UPPER PART

OF LIBRARY

OPEN TO

BELOW

UPPER

PART OF

OFFICES

OPEN TO

BELOW

UPPER

PART OF

OFFICES

OPEN TO

BELOW

JANITOR

CLOSET

STAIR 4

LAW CLERK

TLT RM

CLOSET

CLOSET

TLT RM TLT RM BREAK ROOM

CLOSET

JURY

CONFERENCE

ROOM

STAIR 3

STAIR

ELEV

CHIEF DEPUTY CONFERENCE

ROOM

BREAK ROOM

WORK/COPY

AREA

CLERKS

OFFICE

OFFICE

US ATTORNEY

OFFICE

OFFICE/

CONFERENCE

ROOM

OFFICE/PANTRY

OFFICE

COURTROOM

CLOSET

EXISTING

FIRST FLOOR

ROOF BEYOND

EXISTING

MAILING

PLATFORM

ROOF BEYOND

STAIR 2 ROOF

NEW

MECHANICAL

PENTHOUSE

ROOF

FIRST FLOOR

ROOF BELOW

VEST.

(E)

(E)

FI

LE

N

RE

F:

PL

OT

D

AT

E:

4/2

/20

3:

:56 P

M

4.5

FX

4-

.D W

G

CONFORMED CONSTRUCTION SET

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS

SPECIFICALLY MARKED "EXISTING", "EXIST", OR "(E)".

G3. WHERE PIPING PENETRATES PARTITIONS WITH A SPECIFIED STC RATING,

SEAL PENETRATIONS TO MEET STC RATING SPECIFIED. SEE

ARCHITECTURAL PARTITION DETAILS FOR ADDITIONAL INFORMATION.

6'0 2' 4' 3/8"=1'-0"

BASEMENT MECHANICAL ROOM

ENLARGED PLAN

FX1011

7 9 10

N'

K

AREAWAY

AREAWAY

(E)6" COLT

300-BF DCDA

4" F

BFP

(E)6" INCOMING WATER

FX501

1-1/2"F

4"F 6"F

4" F

4" F

1"F

1-1/2"FWF

WF

TS

TS

6"F

TS

4" F

4"F 4"F4"F

2-1/2"F2-1/2"F

2- 1/2

"F

CONFORMED CONSTRUCTION SET

FI

LE

N

RE

F:

PL

OT

D

AT

E:

4/2

/20

3:

:05 P

M

4.5

FX

1- B1

.D W

G

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS

SPECIFICALLY MARKED "EXISTING", "EXIST", OR "(E)".

NOTES

1. PROVIDE SPRINKLER COVERAGE THROUGHOUT SPACE PER NFPA 13.

2. PROVIDE 1-1/2 INCH ZONE CONTROL ASSEMBLY TO SERVE ELECTRICAL

ROOM 002. PROVIDE 1-1/2 INCH ZONE CONTROL ASSEMBLY TO SERVE

ELEVATOR ROOM. PROVIDE ISOLATION VALVE FOR ELEVATOR PIT.

3. PROVIDE 6 INCH WATER SUPPLY TO STANDPIPE AND SPRINKLER RISER IN

STAIR.

4. NOT USED.

5. PROVIDE 4-INCH CONNECTION TO FREE-STANDING FDC LOCATED ON

EXTERIOR.

FI

LE

N

RE

F:

PL

OT

D

AT

E:

1/1

7/2

4 2 :20

:02 P

M

4.5

FX

1.D W

G

CONFORMED CONSTRUCTION SET

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

N

24"12"0 36" 3/4"=1'-0"

SPRINKLER RISER - DEMOLITION

SECTION

FD-1111

(E)6" INCOMING WATER SUPPLY

(E)6" COLT 300-BF

DOUBLE CHECK

BACKFLOW PREVENTER (E)6"F

4"F

(E)6"F TO BASEMENT & FIRST

FLOOR SPRINKLER SYSTEMS

4"F TO FIRE DEPARTMENT CONNECTION

(E)2" DRAIN

NOT TO SCALE

SPRINKLER ARMOVER

TYPICAL

THREADED CONNECTION

TEE

MAIN

SPRINKLER HEAD CEILING GRID

1"SPRINKLER PIPE

1"SPRINKLER PIPE

1"SPRINKLER PIPE

N

24"12"0 36" 3/4"=1'-0"

SPRINKLER RISER - NEW WORK

SECTION

FX4012

GENERAL NOTES

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS

SPECIFICALLY MARKED "EXISTING", "EXIST", OR "(E)".

NOTES

1. DISCONNECT AND REMOVE EXISTING FDC AND ASSOCIATED PIPE/FITTINGS

BACK TO BASEMENT LEVEL. DISCONNECT AND REMOVE EXISTING MOTOR

GONG.

2. CONNECT FREE-STANDING FDC AND ASSOCIATED PIPE/FITTINGS TO

EXISTING BASEMENT FEED. PROVIDE CHECK VALVE WITH BALL DRIP.

3. CONNECT NEW 6-INCH PIPING FOR BASEMENT AND FIRST FLOOR

SPRINKLER SYSTEMS IN LOCATION INDICATED.

(E)6" INCOMING

WATER SUPPLY

(E)6" COLT 300-BF

DOUBLE CHECK

BACKFLOW PREVENTER (E)6"F

6"F TO FIRST FLOOR

SPRINKLER SYSTEMS

(E)2" DRAIN

4" CHECK VALVE

W/ BALL DRIP

4"F TO

FREE-STANDING FDC

6"F

4"F TO STANDPIPES

AND ZONE CONTROL

ASSEMBLIES

BASEMENT

FIRST

SECOND

THIRD

ATTIC

GRADE

ROOF PENTHOUSE

ZCA

4"F

4"F

WF

COURTROOM

4"F 4"F

WF

TS

TS

ZCA

ZCA

(E )B

FP

TS TS

WFWF

TS

ZCA

WF TS

4"F 4"F

6" F

(E )2

-1 /2"

F

(E )2

-1 /2"

F (E

)2 -1

/2" F

(E )2

-1 /2"

F

(E) 2-1/2"F (E) 2-1/2"F

(E)2-1/2" HOSE (E) 2-1/2" HOSE

(E) 2-1/2" HOSE(E) 2-1/2" HOSE

TS

9 9

TS

11 12

GRADE

ZCA

TSWF7

CONFORMED CONSTRUCTION SET

FI

LE

N

RE

F:

PL

OT

D

AT

E:

4/2

/20

3:

:10 P

M

4.5

FX

1.D W

G

SUMMER

CONSULTANTS

I N C O R P O R A T E D

SUMMER

CONSULTANTS

NOT TO SCALE

SPRINKLER RISER1

G1. VERIFY LOCATION AND DIMENSIONS OF EXISTING EQUIPMENT AND

COORDINATE ALL WORK PRIOR TO THE START OF CONSTRUCTION.

G2. ALL WORK SHALL BE NEW AND PROVIDED UNDER THIS CONTRACT UNLESS

SPECIFICALLY MARKED "EXISTING", "EXIST", OR "(E)".

NOTES

1. DISCONNECT AND REMOVE EXISTING FDC AND ASSOCIATED PIPE/FITTINGS

BACK TO BASEMENT LEVEL. DISCONNECT AND REMOVE EXISTING MOTOR

GONG.

2. EXISTING TO REMAIN INCOMING 6 INCH WATER LINE.

3. PROVIDE 4 INCH ZONE CONTROL ASSEMBLY FOR BASEMENT. PROVIDE

ISOLATION VALVE, CHECK VALVE, WATER FLOW SWITCH, TAMPER SWITCH,

PRESSURE GAUGE, INSPECTORS TEST CONNECTION AND DRAIN.

4. PROVIDE 6 INCH STANDPIPE ISOLATION VALVE AND TAMPER SWITCH.

5. PROVIDE 1-1/2 INCH ZONE CONTROL ASSEMBLY FOR ELECTRICAL ROOM.

PROVIDE ISOLATION VALVE, CHECK VALVE, WATER FLOW SWITCH, TAMPER

SWITCH, PRESSURE GAUGE, INSPECTORS TEST CONNECTION AND DRAIN.

6. PROVIDE 1-1/2 INCH ZONE CONTROL ASSEMBLY FOR ELEVATOR MACHINE

ROOM ROOM. PROVIDE ISOLATION VALVE, CHECK VALVE, WATER FLOW

SWITCH, TAMPER SWITCH, PRESSURE GAUGE, INSPECTORS TEST

CONNECTION AND DRAIN.

7. PROVIDE 2 INCH ZONE CONTROL ASSEMBLY FOR MECHANICAL

PENTHOUSE. PROVIDE ISOLATION VALVE, CHECK VALVE, WATER FLOW

SWITCH, TAMPER SWITCH, PRESSURE GAUGE, INSPECTORS TEST

CONNECTION AND DRAIN.

8. NOT USED.

9. PROVIDE 4 INCH STANDPIPE ISOLATION VALVE AND TAMPER SWITCH,

CONNECT TO EXISTING RISER. RISER TO BE REPLACED IN FOLLOWING

PHASE.

10. PROVIDE 4 INCH ZONE CONTROL ASSEMBLY FOR FIRST FLOOR. PROVIDE

ISOLATION VALVE, CHECK VALVE, WATER FLOW SWITCH, TAMPER SWITCH,

PRESSURE GAUGE, INSPECTORS TEST CONNECTION AND DRAIN..

11. PROVIDE SPRINKLER RISER IN COORDINATED LOCATION FOR

CLEARSTORY.

12. PROVIDE 2-1/2 INCH SPRINKLER RISER UP TO PENTHOUSE. PENTHOUSE

WILL BE PART OF SPRINKLER ZONE 1.

13. NOT USED.

14. NOT USED.

15. PROVIDE (TYP) NEW CONNECTIONS TO EXISTING SPRINKLER ON FIRST

FLOOR.

16. PROVIDE 4 INCH SPRINKLER PIPE TO EXTERIOR FIRE DEPARTMENT

CONNECTION.

17. PROVIDE 1 INCH ISOLATION VALVE AND TAMPER SWITCH TO ELEVATOR PIT.

GENERAL NOTES

(E)

LC

SYMBOLS

RISER IDENTIFICATION

P

NORTH ARROW

COLUMN BUBBLE

DESIGNATION

BREAKLINE

MATCHLINE DESIGNATIONM A T C H L I N E A-A

CENTERLINE

CENTERLINE SYMBOL

EXISTING

POINT OF CONNECTION

TO EXISTING

POINT OF TERMINATION

OF REMOVAL

NOTE NUMBER

P-101 P-401

SHEET NUMBER WHERE

DETAIL IS TAKEN

SHEET NUMBER WHERE

DETAIL IS DRAWN

NUMBER INDICATES

DETAIL

N

ARROW INDICATES

TRUE NORTH AND/OR

PROJECT NORTH

NUMBER INDICATES

SYSTEM RISER NUMBER

LETTER INDICATES

SYSTEM:

P - WASTE/SANITARY

W - DOMESTIC WATER

ST - STORM

DOMESTIC COLD WATER

CONDENSATE DRAIN PIPING

CW

D

GAS PIPING

DOMESTIC HOT WATER

DOMESTIC HOT WATER

CIRCULATION

G

HW

HWC

ST

W WASTE/SANITARY PIPE

STORM PIPE

PIPE TURN UP

PIPE TURN DOWN

STRAINER

GATE VALVE

TMV THERMOSTATIC

MIXING VALVE

O.S.&Y VALVE

BALL VALVE

GLOBE VALVE

CHECK VALVE

REDUCED PRESSURE

BACKFLOW PREVENTER

PRESSURE REDUCING VALVE

UNION

RELIEF VALVE

BALANCING VALVE

GAS COCK

CONCENTRIC REDUCER

ECCENTRIC REDUCER

DIRECTION OF FLOW

PRESSURE GAUGE

THERMOMETER AND WELL

VERTICAL IN-LINE

CIRCULATING PUMP

H.B.

C.O.

W.C.O.

F.C.O.

FL.D. FLOOR DRAIN

FLOOR CLEANOUT

WALL PIPE CLEANOUT

PIPE CLEANOUT

PIPE CAP

WALL HYDRANT,

NON FREEZE/HOSE BIBB

DOUBLE LINE PIPE TURN UP

DOUBLE LINE PIPE TURN DOWN

PIPE CAP

ADA AMERICANS WITH DISABILITIES ACT

ABBREVIATIONS

THERMOSTATIC MIXING VALVETMV

TPV

TYP.

TRAP PRIMING VALVE

TEMPERED WATER

TYPICAL

TW

PVC

PRV

O.C.

PSIA

P.D.

PSIG

SAN

RPM REVOLUTIONS PER MINUTE

SANITARY

SERVICE SINK

PUMPEDDRAIN

PLOYVINYL CHLORIDE

PRESSURE RELIEF VALVE

POUNDS PER SQUARE INCH ABSOLUTE

POUNDS PER SQUARE INCH

POUNDS PER SQUARE INCH GAUGE

PSI

ON CENTER

PRESSURE DROP

HWC

JAN.

LVG.

LBS.

MIN.

M.E.R.

MECH.

MAX.

M.A.V.

MECHANICAL EQUIPMENT ROOM

MANUAL AIR VENT

MECHANICAL

MAXIMUM

MINIMUM

LEAVING

POUNDS

DOMESTIC HOT WATER CIRCULATING

DOMESTIC HOT WATER

JANITOR

HERTZ

INCH(ES)

JUNCTION BOX

HZ

IN.

J-BOX

HW

WALL CLEANOUT

WATER HAMMER ARRESTOR

WALL HYDRANT, NON-FREEZE

WATER GAUGE

WHA

W.C.O.

W.G.

W.H.

DOMESTIC WATER HEATERDWH

ETPV

F.C.O.

GAL.

FLA.

FLR.

FL.D.

ENT.

EXIST.

GPM

GPH

GALLONS PER MINUTE

GALLONS PER HOUR

FULL LOAD AMPS

GALLON

FEET

FLOOR

FLOOR DRAIN

FT.

ELECTRONIC TRAP PRIMING VALVE

DEGREES FAHRENHEIT

EXISTING

FLOOR CLEANOUT

°F

EXISTING

ENTERING

(E)

C.O.

BFP

CONC.

CIRC.

DIA.

CIRCULATING

DOMESTIC COLD WATER

D DRAIN

DISHWASHER

DOWN

DIAMETER

DW

DN.

CLEANOUT

CONCRETE

CW

BACKFLOW PREVENTOR

REDUCED PRESSURE

VENT THRU ROOF

WASTE OR WIDTH

VENT OR VOLTS

WITH

VTR

A.P.

A.D.

ABV.

A.F.F.

ACCESS DOOR

ABOVE FINISHED FLOOR

ABOVE

ACCESS PANEL

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

UNDERWRITER LABORATORIESUL

LENGTHL

DEMOLITION LINETYPE

M MOTOR OPERATED

BUTTERFLY VALVE

V VENT PIPE

CONT. CONTINUATION

Cu COPPER

VERTICALVERT.

PLUMBING FIXTURE SCHEDULE

WATER CLOSETP-1 2"

V

CONNECTION SIZE, INCHES

4"

W

1"

CW

HW

FLOOR MOUNTED, BOTTOM OUTLET, SIPHON JET FLUSHING ACTION, VITREOUS CHINA, HIGH EFFICIENCY TOILET W/ ELONGATED BOWL, TOP SPUD WITH OPEN FRONT TOILET SEAT LESS COVER WITH STAINLESS STEEL CHECK HINGE.

PROVIDE WITH MANUALLY OPERATED, EXPOSED, DUAL FLUSH, FLUSHOMETER VALVE, SLOAN WES 111 UPPERCUT

OR APPROVED EQUAL.

TW

WATER CLOSETP-2 2"4" 1" - -

URINALP-3A 1-1/2"2" 3/4" - ABAAS COMPLIANT, WALL MOUNTED, 0.125 GPF, VITREOUS CHINA, HIGH EFFICIENCY, TOP SPUD, WASHDOWN URINAL. PROVIDE WITH MANUALLY OPERATED, POLISHED CHROME, EXPOSED, 0.125 GPF FLUSHOMETER VALVE.

LAVATORYP-4 1-1/2"1-1/2" 1/2" 1/2"

ABAAS COMPLIANT, VITREOUS CHINA UNDERMOUNT LAVATORY, SLOAN SS-3001 OR APPROVED EQUAL. PROVIDE WITH SINGLE HOLE FAUCET WITH POP-UP DRAIN, 0.5 GPM. MAX., HANSGROHE JOLEENA 100 FAUCET WITH SLOAN ETF-460A DRAIN OR APPROVED EQUAL. PROVIDE LAVATORY WITH OATLEY DEARBORN SAFETY SERIES SINK TRAP

(OR APPROVED EQUAL) AND PLASTIC TUBULAR P-TRAP COVERS AT EXPOSED PIPING.

LAVATORYP-5 1-1/2"1-1/2" 1/2" 1/2" ABAAS COMPLIANT, WALL-HUNG, LEDGEBACK, VITREOUS CHINA LAVATORY WITH OVERFLOW. PROVIDE SLOAN SS-3106 LAVATORY OR APPROVED EQUAL. PROVIDE WITH SINGLE HOLE FAUCET WITH POP-UP DRAIN, 0.5 GPM. MAX., HANSGROHE JOLEENA 100 FAUCET WITH SLOAN ETF-460A DRAIN OR APPROVED EQUAL. PROVIDE LAVATORY WITH OATLEY DEARBORN SAFETY SERIES SINK TRAP (OR APPROVED EQUAL) AND PLASTIC TUBULAR P-TRAP COVERS AT

EXPOSED PIPING.

WATER CLOSET / LAVATORY

COMBINATION UNIT

P-6 2"4" 1" 1/2" ABAAS COMPLIANT, FLOOR MOUNTED, OFFSET, 14 GAUGE 304 S.S., 1.28 GPF HIGH EFFICIENCY HYDRAULIC FLUSH VALVE, BLOWOUT TYPE TOILET WITH INTEGRAL LAVATORY WITH DUAL TEMP. ELECTRONIC METERING FAUCET.

PROVIDE UNIT WITH INTEGRAL TOILET PAPER HOLDER AND REAR SERVICE ACCESS.

USMS SERVICE SINKP-7 1-1/2"2" 1/2" 1/2"

ABAAS COMPLIANT, SINGLE BOWL 304 STAINLESS STEEL SINK BUILT INTO STAINLESS STEEL CASEWORK. PROVIDE WITH DECK MOUNTED, SWING DOWN EYE/FACE WASH. PROVIDE SINK WITH 1.5 GPM DECK MOUNTED GOOSENECK FAUCET AND VANDAL PROOF LEVER HANDLES. PROVIDE SINK WITH OATLEY DEARBORN SAFETY SERIES SINK TRAP (OR APPROVED EQUAL) AND PLASTIC TUBULAR P-TRAP COVERS AT EXPOSED PIPING. PROVIDE ANSI Z358.1 COMPLIANT PULL-DOWN PLUMBED EYE/FACE WASH TO DELIVER 3.0 GPM AT 30 PSI. PROVIDE ASSE 1071 CERTIFIED EMERGENCY MIXING VALVE CAPABLE OF DELIVERING A MIN. OF 4 GPM AT 30 PSI. SET TEMP. TO DELIVER 80° F TEPID

WATER.

1/2"

DESIG. FIXTURE REMARKS 1

NOTES:

1 ALL ABAAS RIM MOUNTING HEIGHTS IN ACCORDANCE WITH THE

ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD AND IPC

REQUIREMENTS.

2CONTRACTOR TO INSTALL ALL FIXTURES AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. PROVIDE PIPING CONNECTIONS PER FIXTURE CONNECTION SCHEDULE. PROVIDE

PLUMBING FIXTURES, VALVES AND APPURTENANCES LABELED UNDER THE U.S. ENVIRONMENTAL

PROTECTION AGENCY WATERSENSE PROGRAM.

EXPANSION TANK SCHEDULE

UNIT

NO.

TANK VOL.

(GALLONS)

ACCEPT. VOL.

(GALLONS)

INITIAL CHARGE

(PSIG) TANK SIZE SERVICE

ET-1 20 82 32"Hx16"Ø WATER SYSTEM5

PROVIDE 3/4" DRAIN, VALVE, HOSE CONNECTION AND CAP.

DOMESTIC HOT

BASIS OF DESIGN

PROVIDE EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.

AMTROL, MODEL: ST-42VC

THERM-X-TROL

115V/1Ø/60Hz

CHARACTERISTICS

ELECTRICAL

PUMP SCHEDULE

WATERCP-3

DESIG.

INLINE

FLUIDTYPE GPM (FT. W.G.)

HEAD RPM SERVICE LOCATION

DOM. WATER MER 0044 15 3300

MOTOR

1/6 HP

REMARKS

NOTES:

1 BASIS OF DESIGN: B & G MODEL: PL-30

2 REFER TO DETAIL 2/P-001/P-001 FOR INSTALLATION.

VERTICAL IN-LINE

CIRCULATION PUMP

0-30 PSI

PRESSURE GAUGE

ISOLATORS.(TYP.)

PROVIDE VIBRATION

3 PROVIDE EQUIPMENT IN ACCORDANCE WITH

MANUFACTURER'S RECOMMENDATIONS.

1 2

NO SCALE

IN-LINE PUMP

DETAIL

P-001,P-1012

1/2"CW TRAP PRIMER SUPPLY

DOMESTIC COLD WATER

(DCW) LINE

TRAP PRIMER VALVE

DISTRIBUTION UNIT AVAILABLE

FOR 5 ADDITIONAL LINES)

1/2"CW TRAP PRIMER LINE

FLOOR DRAIN

FLOOR SLAB

WASTE

SEALANT

BACKING

MATERIAL

SLEEVE

THRU SLAB

WATERPROOF

SEALANT

SUPPLY RISER

TYPICAL BRANCH LINE

WATER HAMMER

ARRESTOR

PDI "A"

PDI SYMBOL

NOTES:

1. PREFERRED INSTALL WATER HAMMER ARRESTORS AT THE

END OF BRANCH LINE BETWEEN THE LAST TWO FIXTURES SERVED.

2. ONE WATER HAMMER ARRESTOR PER 20' LINE, AND ANOTHER FOR

BRANCHES OVER 20' IN LENGTH.

3. THE SUM OF FIXTURE UNIT RATING OF UNITS OVER 20' IN LENGTH

SHALL BE EQUAL TO OR GREATER THAN THE DEMAND OF THE

BRANCHES.

WATER HAMMER ARRESTOR SCHEDULE

PDI SYMBOL A B C D E F

FIXTURE UNIT

RATING 1-11 12-32 33-60 61-113 114-154 155-330

THERMOSTATIC MIXING

VALVE SET TO BLEND 140°F

HW WITH CW TO 110°F

1"Ø 140F HOT

WATER

1-1/4"Ø TEMPERED

WATER OUTLET

GATE VALVE

1"Ø

2"Ø COLD WATER

THERMOSTATIC MIXING VALVE SCHEDULE

MARK LOCATION TYPE

MINIMUM

FLOW (GPM)

MAXIMUM

PRESSURE LOSS

PSI

FLOW AT

MAX. P.D. (GPM)

TMV-1 BASEMENT

MER ASSE 1017 0.5 10.0 39.0

NO SCALE

TRAP PRIMER (TPV-1)

DETAIL

P-4017

NO SCALE

WATER HAMMER ARRESTOR

DETAIL

P-6015

NO SCALE

THERMOSTATIC MIXING VALVE

DETAIL

P-001,P-4014

3/4" DOMESTIC COLD

WATER INLET

UNION

ANCHOR CLIP

SCREWDRIVER STOP

REMOVABLE WHEEL

HANDLE

REMOVABLE KEY

HOSE

CONNECTION

18 GAGE, TYPE 304 S.S.

RECESSED BOX

16 GAGE, TYPE 304 S.S.

WALL FLANGE

DETAIL

RECESSED BOX TYPE

WALL HYDRANT (WH-1)

P-001 NO SCALE6

SERVICE SINKP-8 1-1/2"3" 1/2" 1/2"

ONE PIECE, CORNER FLOOR MOUNTED, PRECAST TERRAZZO MOP SERVICE BASIN WITH STAINLESS STEEL CAP ON THRESHOLD. PROVIDE WITH EXPOSED, WALL MOUNTED, ROUGH CHROME PLATED FINISH JANITOR SINK FAUCET

WITH VACUUM BREAKER, PAIL HOOK AND WALL BRACE.

WATER FOUNTAINP-9 1-1/2"1-1/2" 1/2"

ABAAS COMPLIANT, BI-LEVEL DOUBLE BUBBLER, REFRIGERATED, FILTERED, DRINKING FOUNTAIN WITH BOTTLE FILLING STATION. WATER CHILLING CAPACITY OF 8 GPH OF 50°F DRINKING WATER BASED UPON 80°F INLET WATER AND 90°F AMBIENT AIR TEMPERATURE. PROVIDE ELKAY MODEL LZWS-LRPBM28K OR APPROVED EQUAL.

KITCHEN/PANTRY SINKP-10 1-1/2"1-1/2" 1/2" 1/2"

ABAAS COMPLIANT, QUARTZ, SINGLE BOWL, UNDERMOUNT SINK WITH REAR CENTER DRAIN PLACEMENT, ELKAY ELGUAD2519PD OR APPROVED EQUAL. PROVIDE WITH SINGLE HOLE, DECK MOUNTED, SINGLE LEVER HANDLE HIGH ARC PULL-OUT KITCHEN FAUCET WITH 1.75 GPM AERATOR, HANSGROHE FOCUS OR APPROVED EQUAL. PROVIDE SINK WITH OATLEY DEARBORN SAFETY SERIES SINK TRAP (OR APPROVED EQUAL) AND PLASTIC TUBULAR P-TRAP

COVERS AT EXPOSED PIPING. PROVIDE 1/2 HP CONTINUOUS FEED GARBAGE DISPOSAL.

RUNNING TRAP

URINALP-3 1-1/2"2" 3/4" - WALL MOUNTED, 0.125 GPF, VITREOUS CHINA, HIGH EFFICIENCY, TOP SPUD, WASHDOWN URINAL. PROVIDE WITH

MANUALLY OPERATED, POLISHED CHROME, EXPOSED, 0.125 GPF FLUSHOMETER VALVE.

REMOVE PIPE

PROVIDE NON-SHRINK GROUT

FLUSH WITH EXISTING SURFACE

APPLY BONDING AGENT

TO EXISTING SURFACE

CHIP CONCRETE SURFACE (E)CONCRETE

16 GAUGE SHEET

METAL COVER

6"x6"x1/4" STEEL

PLATE

(4)3/8"Ø DRILLED CONCRETE

ANCHORS. MIN. 3" EMBEDDMENT

TYP. ALL 4 LEGS

WELD CONTINUOUSLY

MANUFACTURER'S

TANK SADDLE

200 GALLON DOMESTIC

HOT WATER STORAGE TANK

MANUFACTURERS FACTORY

FABRICATED SUPPORTS

DWST-1

3/4"DRAIN VALVE W/

HOSE CONNECTION

P&T RELIEF VALVE SIZED

BY MANUFACTURER

UNION (TYP.)

AQUASTAT. SETTING

FOR 110°F SYSTEM:

ON AT 95°F

OFF AT 105°F

12" MIN.

"M

IN

AQUASTAT. SETTING

FOR 110°F SYSTEM:

ON AT 95°F

OFF AT 105°F

3/4"HWC TO (E)DWH

3/4"HW-140°F FROM (E)DWH

(E)DWH

THERMOSTATIC

MIXING VALVE TMV-1

SET @ 110°F L.W.T.

(E)CP-1. PUMP SHALL

RUN CONTINUOUSLY

NO SCALE

DOMESTIC WATER HEATING SYSTEM

DETAIL

P-4011

(E)BASEMENT. FLR.

CP-3

P-0012"HW-140°F2"HW-120°F

SEE P-401 FOR

CONTINUATION

1-1/4"HWC

2"CW

2"CW SEE P-401

FOR CONTINUATION

3/4"HWC

1"CW

THERMOMETER & WELL

RANGE: 30°-180°F

P-001

THERMOMETER

3 1/2" MIN

EXTENSION NECK TO MATCH

INSULATION THICKNESS

SEPARABLE

THERMOMETER WELL

2x2 REDUCING TEE

SEE PLANS AND

DETAILS…

This is the start of the file's text. The full file is on GovTribe.