C15578-Attachment C-44-Curb Ramp Inspection Standard Comments-Add2.pdf
PDF 425 KB Posted
- Solicitation number
- S-73000-00014433
- Issued by
- Columbia County, Condon City, Oregon
About this file
This is an ADA Ramp Inspection Forms document prepared by the Oregon Department of Transportation, updated February 11, 2020, establishing standardized comments and inspection protocols for new construction curb ramp compliance evaluations. The document provides a comprehensive reference guide for inspectors conducting ADA accessibility audits on curb ramps and associated pedestrian infrastructure. It outlines measurement protocols, location identifiers, and object classifications necessary to document compliance issues such as lip depths, truncated dome conditions, obstructions, inlet placements, and surface irregularities. The forms standardize terminology and abbreviation systems to ensure consistent documentation across inspection activities, including specifications for ramp runs, turn spaces, sidewalk dimensions, and grade breaks. The guide facilitates systematic evaluation of pedestrian routes to verify compliance with accessibility standards for newly constructed or modified curb ramp installations.
The document functions as an internal operational standard rather than a procurement or contract solicitation. It contains no pricing information, set-asides, incumbent contractors, funding sources, or contractual terms. Instead, it serves as a technical reference tool for Oregon Department of Transportation staff and contractors performing ADA compliance inspections. The standardized comment codes, measurement abbreviations, and object designation systems enable consistent data collection and reporting across multiple inspection sites and personnel, supporting quality assurance in new construction ADA compliance verification processes.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADA Ramp Inspection Forms List of New Construction
Standard Comments
Oregon Department of Transportation
Updated:
02/11/2020
[MEASURE] IN LIP AT [LIP LOCATION] /[OBJECT*]
[MEASURE] IN [LIP TYPE] LIP
[OBJECT] ON TD
CIR TD
RED TD
BORO [OBJECT]
[OBJECT] OPRT
[OBJECT] ON [LOCATION]
[OBJECT] BT RP
[OBJECT] WPL
INLET [INLET LOCATION]
BMTS
BMTS X [TURN SPACE X] AND Y [TURN SPACE Y]
AC RP
BRK RP
MST
CRS OPP
NO RR#
RCRB 1
RCRB 2
RR# NO SWLK
RR# OPP
SWLK EQL RR#
#FT SWLK BT RR# TS
COMMENTS:
LIPS
TRUNCATED DOME
BACK OF RAMP OBSTRUCTION
OBSTRUCTING PEDESTIAN ROUTE
OBJECT ON RAMP
OBJECT BETWEEN RAMPS
WITHIN PROXIMITY LIMITS
INLET/CATCH BASIN
END OF WALK
SURFACE TYPE
OTHER COMMENTS
Depth in Inches of Lip at a Location or Object listed on the next page Depth in Inches from certain Lip Type listed on the next page Object, from list on next page, ON Truncated Dome Cast Iron Truncated Domes Red Truncated Domes Back Of Ramp Obstruction by Object, from list on next page Object, from list on next page, Obstructing Pedestrian Route Object, from list on next page, ON a Location from the next page Object, from list on next page, Between Ramps Object, from list on next page, Within Proximity Limits Inlet AT Location from list on next page Bottom Turn Space Bottom Turn Space In Comments when two Turn Spaces exist Asphalt Ramp Brick Ramp Mixed Surface Type Curb Running Slope Sloping Opposite Direction No ramp run 2 and/or 3 Return Curb on 1 Side Return Curb on Both Sides Ramp Run leads to no where Ramp Run (1, 2, or 3) Sloping Opposite Direction Sidewalk Consistent With Ramp Run (2 or 3) Length of Sidewalk Between Ramp Run and Turn Space
FORMAT:
CRK [LOCATION]
DO
EXP
GB [LOCATION]
ICRR#
INLET XING
STR
#FT BT RR/DR
DESCRIPTION:
Crack on a specified location of concrete from the list on the next page Drop Off within proximity limits Curb Exposure is less than 3 inches Grade Breaks are NOT perpendicular on specified area from list on the next page Inconsistent Ramp Run # Inlet is within the Crossing Striping Issue Length of Sidewalk Between Ramp Runs or Driveway
Addendum 2
ADA Ramp Inspection Forms List of New Construction
Standard Comments
Oregon Department of Transportation Updated:
02/11/2020
[INLET LOCATION]:
[TURN SPACE X]
[TURN SPACE Y]
[MEASURE]:
[LIP LOCATION]:
[LIP TYPE]:
[LOCATION]:
HALF, 1, 2,
3, etc . . .
BOC Back Of Curb BRR1 Bottom of Ramp Run 1 (Only if no curb exists) ETS Edge Of Turn Space
FOC Face of Curb FOG Front Of Gutter TD Truncated Domes TRR# Top of Ramp Run 1, 2, or 3 WPL Within Proximity Limit
OBJECT BCH Bench BR Bike Rack
BIO Bioswale BOL Bollards BLDG Building
BST Bus Stop CBX Communication Box CRB Curb CV* Communication Vault
SL# W# Slope X and Turn Space Width SL# L# Slope Y and Turn Space Length
EM Electric Meter FD* French Drain FNC Fence
FRH Fire Hydrant GV* Gas Valve
GWR Guy Wire INLET* Inlet/Catch Basin
JBX* Junction Box LD Loop Detector LND Landscaping
LP Light Pole MB Mailbox MH* ManHole PCC Raised Concrete
PDP Pedestrian Pole RPB Raised Planting Bed
RWL Retaining Wall RXP Railroad Crossing Pole SGCC Traffic Signal Controller Cabinet
SGN Sign
SGP Traffic Signal Pole SM Survey Marker
TLP Utility Pole BARR Concrete Barrier/Guardrail
TC Trash Can TR Tree
WH Weep Hole WM* Water Meter WV* Water Valve
BT RP Between Ramp FOC Face Of Curb FOG Front Of Gutter NR FLR Near Flare NR RR# Near Ramp Run 2 or 3 WPL Within Proximity Limits
BT RP Between Ramps FLR Flare RR# Ramp Run TS Turn Space WPL Within Proximity Limits AC Asphalt
BVL Beveled
FINAL