This document provides technical specifications for the construction of a new Emigrant Creek Interagency Fire Facility in Hines, Oregon. The project involves replacing two existing converted residences used as fire offices with a new 14,800 square foot prefabricated facility that may consist of one or more buildings. The facility will include site demolition of the existing fire offices, grading, drainage, utility connection, landscaping, and hardscaping.

The document includes reference specifications and drawings to guide the design and construction of the facility's IT rooms, telecommunications wiring systems, electronic access control, fire alarm and detection systems, video surveillance, and more. Specifically, it lists technical provisions, materials and methods, cable tray specifications, underground control cable and power distribution guidelines, an IT room shutdown panel drawing, surge protective device requirements, public address system standards, and sample drawings for IT rooms, access control, CCTV, utilities and more. The Forest Service will provide these references to the successful bidder for the project.

View the file

Other files for this federal contract opportunity

Other files attached to Emigrant Creek Interagency Fire Facility, newest first.
File Type Posted
Amd002.docx DOCX document
Amd002_RFI_Responses.docx DOCX document
Amd001.docx DOCX document
Amd001_RFI_Responses.docx DOCX document
c.ATT 2 - 20180406 AE Submission-ECRD.docx DOCX document
c.ATT 2 - SR20190008 ECRD Equipment Load Listing.xls XLS spreadsheet
d.ATT 4 - Wage_Determination.docx DOCX document
c.ATT 2 - 041717_Bldg_Sec_Policy_FINAL.pdf PDF
a.offerors_packet.doc DOC document
c.ATT 2 - Room Data Sheet-Emigrant Creek 20200116.pdf PDF
c.ATT 1 - CombinedSpecPackage.pdf PDF
b.final_solicitation_package.doc DOC document
c.ATT 2 - SR20190008 ECRD IT Load Listing.xls XLS spreadsheet
c.ATT 3 - ECIFF 3.0 Drawings.pdf PDF
c.ATT 2 - ITelectDesignGuide020160310.pdf PDF
c.ATT 2 - AccessControlSystemDesignGuidelines-20180702.pdf PDF
Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USDA Forest Service Section J

SECTION J

TABLE OF CONTENTS

list of Documents

1. A/E Submission Instructions for Forest Service Construction Projects

2. Building Physical Security Requirements

3. Access Control System USDA ePACS Design Guidelines

4. Telecommunication Wiring & Electrical Systems Design Guidelines

5. Room Data Sheets

6. Electrical Load Lists

a. IT Room Load Listings

b. Equipment Load Listings

Government Reference Specifications:

The following list of documents will be provided to the successful bidder. They are reference documents only and their use is optional.

Division 26 26 00 10 General Technical Provisions 26 00 50 Basic Materials and Methods 26 01 14 Cable Trays 26 04 00 Underground Control Cable and Power Distribution 26 24 11 IT Room Shutdown Panel 26 43 13 Surge Protective Device

Division 27 27 51 13 PA Systems 27 00 00 Telecommunications Wiring Systems

Division 28 28 16 00 Intrusion Detection 28 23 00 Video Surveillance 28 13 00 Access Control System 28 31 11 Fire Alarm and Detection Systems Government reference DRAWINGS:

1. IT room sample layout drawing for racks, UPS power panels, cooling, electronic panels and others.

2. Sample IT Room layout

3. Sample IT room shut down panel drawing.

4. Sample access control system building specifications and drawings

5. Sample CCTV system building specifications and drawings

6. Sample IT Detail drawing.

7. Sample Site utility details

END OF SECTION

March 2019 Emigrant Creek Inter-Agency Fire Facility Page 1 of 2