Bridge Inspection Rpt_5460-187P-2022_Redacted.pdf

PDF 2 MB Posted

Attached to
Great Smoky Mountains National Park - Cosby Entrance Road and Cosby Picnic Area Road
Solicitation number
693C73-24-B-000016
Issued by

About this file

This document is a Culvert Inspection Report for the Crying Creek Culvert located in the Great Smoky Mountains National Park. The report provides an assessment of the condition of the culvert structure, including recommendations for maintenance and rehabilitation work.

The key details are:

  • The culvert is designated as Structure No. 5460-187P and was last inspected on 5/11/2022.
  • The report recommends minor maintenance tasks such as removing drift from the barrels and installing markers. The estimated cost for these maintenance items is $222.70.
  • No rehabilitation or reconstruction work is recommended at this time.
  • The culvert has a load rating that meets or exceeds the design load capacity.
  • The report provides detailed information on the culvert's dimensions, construction materials, and condition of various components.

View the file

Other files

File Type Posted
Results of Bid Opening - Project TN NP GRSM 21(1).pdf PDF
Amendment 0001 - TN NP GRSM 21(1).pdf PDF
VETS-4212 Form.pdf PDF
NPS Uniguide Signs Manual Attachment - Park Boundary.pdf PDF
NPS Uniguide Signs Manual Attachment - 02NPS Sign Program Motorist Guidance Manual.pdf PDF
FP14_Eng.pdf PDF
PEPC_96372_signed_CE.pdf PDF
PEPC_109201_LetterOfComp_2022_06_21.pdf PDF
Plans - TN NP GRSM 21(1).pdf PDF
TN NP GRSM 21(1) Hydraulics Memo_01-23-24_.pdf PDF
PEPC_109201_CE Package_2022_06_21.pdf PDF
IFB Solicitation - TN NP GRSM 21(1).pdf PDF
ADV Bidders Qualifications Form.doc DOC document
TN NP GRSM 21(1)_NPS Uniguide Sign Layout.pdf PDF
NPS Uniguide Signs Manual Attachment - FeeSymbol sign.pdf PDF
NPS Uniguide Signs Manual Attachment - Parking Control.pdf PDF
VETS-4212 Form.pdf PDF
Bridge Inspection Rpt_5460-186P-2022_Redacted.pdf PDF
NPS Uniguide Signs Manual Attachment - Motorist-Guidance-Sign-Grids.pdf PDF
NPS Uniguide Signs Manual Attachment - NPS Motorist Guidance Symbols.pdf PDF
NPS Uniguide Signs Manual Attachment - Motorist-Guide-Fabrication-Details.pdf PDF
Categorical Exclusion Form (NEPA).pdf PDF
NPS Uniguide Signs Manual Attachment - Pathfinder.pdf PDF
TN NP GRSM 21(1) Pavement Report Addendum.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CULVERT INSPECTION REPORT

CRYING CREEK CULVERT

COSBY CAMPGROUND ACCESS ROAD OVER CRYING CREEK

GREAT SMOKY MOUNTAINS NATIONAL PARK

LN

STRUCTURE NO. 5460-187P

INSPECTION TYPE: ROUTINE

INSPECTION DATE: 5/11/2022

ED

Report prepared by:

Federal Highway Administration Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 https://bridge.flhd.fhwa.dot.gov

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5460-187P

CRYING CREEK CULVERT INSPECTION DATE : 05/11/2022

PRIORITY OF IMPROVEMENT226

A (Critical) - Structure is closed, in immediate damage of collapse, or presents a critical safety danger.

B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain open at reduced loads or with frequent inspections.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventive maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

D

Item No.

Maintenance Recommendations

(GENERALLY NOT FLHP ELIGIBLE)

QTY. UNIT UNIT

COST

PRELIM.

COST

ESTIMATE

62.5

REMOVE DRIFT FROM BARRELS.

1 LS

222.7

INSTALL MARKERS ON EAST SIDE OF STRUCTURE.

1 EA

PRELIM. MAINTENANCE TOTAL :

Item No.

REHABILITATION/RECONSTRUCTION

(TYPICALLY NEEDED WITHIN 5 YEARS)

QTY. UNIT

UNIT

COST

PRELIM. COST ESTIMATES

REHAB RECONSTR

PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :

COST ESTIMATE SUMMARY

PRELIM. MAINTENANCE TOTAL :

PRELIM. REHABILITATION TOTAL :

PRELIM. RECONSTRUCTION TOTAL : ..

TOTAL ITEMIZED COSTS:

PRELIMINARY ESTIMATE TOTAL * :

(*Includes typical contract costs for mobilization, traffic control and design/construction engineering: but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for planning purposes only; they should not be used as a complete or final engineers estimate.)

Remarks : Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.

STRUCTURE LOAD RATING STRUCTURE NO. 5460-187P

CRYING CREEK CULVERT INSPECTION DATE: 05/10/2022

TRUCK TYPE

INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)

TONS METRIC TONS TONS METRIC TONS

H 20 18 33 30

HS 36 33 59 54

TYPE 3 25 23 41 37

TYPE 3S2 36 33 59 54

TYPE 3-3 40 36 66 60

DESIGN LOADING: 0 - UNKNOWN

X CAPACITY MEETS OR EXCEEDS DESIGN LOAD

CAPACITY IS LESS THAN DESIGN LOAD

ORIGINAL LOAD RATING CALCULATION APPLICABLE

ORIGINAL LOAD RATING CALCULATION REVISED

DATE OF LOAD RATING CALCULATION: 05/16/2016

LOAD RATING CONTROLLED BY: COVER OVER CULVERT

REMARKS: SEE STRUCTURE FILE FOR LOAD RATING CALCULATIONS.

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5460-187P

STRUCTURE IDENTIFICATION

(201) PARK: GREAT SMOKY MOUNTAINS NATIONAL PARK

(202) STRUCTURE NAME:..............CRYING CREEK CULVERT

(203) STRUCTURE KIND:............... 2 - CULVERT

(204) STRUCTURE NUMBER:.........5460-187 P

4 - SOUTHEAST(205) NPS REGION:

(206) ROUTE CODE NUMBER:

(207) ROAD SECTION NO:............. 187P

(208) NPS ROAD CLASS:............... 2 - CONNECTOR ROAD

(209) WITHIN NPS BNDRY?:.......... Yes

(210) OPERATING UNIT:.................N. DIST.

(211) PROJECT NO(S):

(212) DRAWING NUMBERS:...........NONE

(21) MAINTAINED BY:......................66 - NATIONAL PARK SERVICE

(22) OWNER:................................... 66 - NATIONAL PARK SERVICE

(1) STATE:

(2) STATE HWY. AGENCY DIST:

(3) COUNTY CODE:

(4) CITY / PLACE CODE:

(5) INVENTORY ROUTE:

(6) FEATURES INTERSECTED:

(7) FACILITY CARRIED:

(8) STATE STRUCTURE NO:

(9) LOCATION:

(10) INV. RTE. - MIN. VERT. CLR:

(11) MILE POINT:

(27) YEAR BUILT:

(106) YEAR RECONSTRUCTED:

(20) TOLL:

(37) HISTORIC DESIGNATION:

474 - TENNESSEE

47029 COCKE

00000

1 6 4 00021 0

CRYING CREEK

COSBY CAMPGROUND ACCESS

ROAD

5460187P0000000

0 2 MILES SOUTH FROM TN ROUTE

32.

99.99 FT ( 99.99 M)

0 20 (KM PT: 0.32 )

3 - ON FREE ROAD

5 - NOT ELIGIBLE

STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE

(43A) MAIN STR. MATERIAL:..........3 - STEEL (44A) APPR. STR. MATERIAL:............ 0 - Other

(43B) MAIN STR. TYPE:.................. 19 - CULVERT (INCLUDES FRAME (44B) APPR. STR. TYPE:.................... 00 - OTHER

CULVERTS)

(45) NO. OF MAIN SPANS:..............002 (46) NO OF APPROACH SPANS:

(48) MAX. SPAN LENGTH:..............17 FT ( 5.2 M)

(49) STRUCTURE LENGTH:........... 36.0 FT ( 11 M) (108) WEAR SURFACE/PROTECT SYSTEM:

(216A) ABUTMENT #1 FDN:........... 2 - SPREAD FTG ON BEARING MAT'L A) TYPE WEARING SURFACE:.. N - NA

(216B) ABUTMENT #2 FDN:........... 2 - SPREAD FTG ON BEARING MAT'L B) TYPE MEMBRANE:................. N - NA

(217A) PREDOM. PIER FDN:.......... 2 - SPREAD FTG ON BEARING MAT'L C) TYPE PROTECTION:.............. N - NA

(217B) SECOND. PIER FDN:.......... 6 - N/A (218) IS SALT USED?.......................... NO

(107) DECK TYPE:.......................... N - NOT APPLICABLE

LOAD RATING AND POSTING

(31) DESIGN LOAD:.........................0 - UNKNOWN (41) LOAD RESTRICTION:.................. A - OPEN

(66) INVENTORY RATING:..............36.0 METRIC TONS) (70) BRIDGE POSTING:...................... 5 - EQUAL TO OR ABOVE LEGALTONS ( 32.7

LOADS

(64) OPERATING RATING:..............59.0 TONS ( 53.5 METRIC TONS)

INSPECTION DATES

(90) INSPECTION DATE: 05/11/2022 (91) FREQ. OF INSP: 48 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):

(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL:.......... N

(220) SPECIAL STUDY TYPE: 0 - NONE INSP. EVERY MONTHS - LAST INSP:

(221) SPECIAL STUDY DATE: (B) UNDERWATER:..................... N

INSP. EVERY MONTHS - LAST INSP:

(C) SPECIAL INSPECTION:........ N

INSP. EVERY MONTHS - LAST INSP:

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5460-187P

GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA

(16) LATITUDE:................................ 35° 46'53 80" N (51) CURB TO CURB WIDTH:............ 0 0 FT ( 0 M)

(17) LONGITUDE:............................ 83°13 '01.10" W (52) DECK WIDTH:.......................... 0 0 FT ( 0 M)

(19) DETOUR LENGTH:.................. 99 MI ( 159 KM) (32) APPR. ROADWAY WIDTH:...... 27.0 FT ( 8.2 M)

(28A) LANES ON STRUCT:.............02 (213) APPR. PAVEMENT WIDTH:... 19.0 FT ( 5.8 M)

(28B) LANES UNDER STRUCT:......00 LEFT SHOULDER:............... 4 0 FT ( 1.2 M)

(42A) SERVICE ON:.........................1 - HIGHWAY RIGHT SHOULDER:.......... 4 0 FT ( 1.2 M)

(42B) SERVICE UNDER:................. 5 - WATERWAY (33) BRIDGE MEDIAN:.................... 0 - NO MEDIAN

(29) AVG DAILY TRAFFIC:..............1 (34) SKEW ANGLE:......................... 50 °

(30) YEAR OF ADT:......................... 2019 (35) STRUCTURE FLARED:............ 0 - NO FLARE

(114) FUTURE ADT:.........................2 (47) TOTAL HORIZ. CLEARANCE:.. 27 FT ( 8.2 M)

(115) YEAR OF FUTURE ADT:........2039 (50) SIDEWALKS

(101) PARALLEL STRUCTURE:......N - NO PARALLEL STRUCTURE LEFT:.................................... 0 0 FT ( 0 M)

(38) NAVIGATION CONTROL:.........0 - NO NAVIGATION CONTROL ON RIGHT:.................................. 0 0 FT ( 0 M)

WATERWAY (BRIDGE PERMIT NOT

REQUIRED)

(39) VERTICAL CLEARANCE:.........0 FT ( 0 M) (214) BRIDGE RAIL TYPE

0 - N/A(40) HORIZ. CLEARANCE:..............0 FT ( 0 M) RAIL CONFIGURATION:

(111) ABUT OR PIER PROT:........... MATERIAL:........................... 0 - N/A

LATERAL UNDERCLEARANCE: DESIGN TYPE:..................... 0 - N/A

(55) RIGHT:..............................00 FT ( 0 M) (215) BRIDGE RAIL HEIGHT:.......... .00 FT ( 0 M)

(56) LEFT:................................ 0 FT ( 0 M) (53) MIN. VRT. CLR. OVER DECK: 99.99 FT ( 99.99 M)

(54) MIN. VRT. UNDRCLRANCE:... .00 FT ( 0 M)

CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST

(58) DECK:....................................... N (67) STRUCTURAL EVALUATION:

(59) SUPERSTRUCTURE:...............N (68) DECK GEOMETRY:......................N

(60) SUBSTRUCTURE:.......... N (69) UNDERCLEARANCES:................ N

(61) CHANNEL:................................7 (71) WATERWAY ADEQUACY:

(62) CULVERT:.................................7 (72) APPROACH ALIGNMENT:

(222) APPROACHES:...................... 6 (113) SCOUR CRITICAL:.................... 5 - SCOUR WITHIN LIMITS OF

FOOTING OR PILES

(223) RETAINING WALL:.................N (225) PURPOSE OF IMPROVEMENT: 1 - MAINTENANCE

(36) TRAFFIC SAFETY FEAT: N N N N (226) PRIORITY OF IMPROVEMENT: D - MINOR

(75A) TYPE OF WORK:................... (227) MAINTENANCE COST:.............$

(75B) WORK DONE BY:.................. (228) REHAB / RECNSTR COST:..... $

(76) IMPROVEMENT LENGTH:....... FT ( 0 M) (229) CONSTRUCTION COST:.......... $

ADDITIONAL INFORMATION

(230) STRUCTURE HISTORY:

2009-ROADWAY RESURFACED.

(231) ADDITIONAL CONSIDERATIONS:

(330) ADDITIONAL CONFIGURATION INFORMATION:

Inspector: Mike Putallaz Structure Number: 5460187P0000000

Inspection Date: 05/11/2022 Facility Carried: COSBY CAMPGROUND

Culvert Inspection Report

Pictures

PHOTO 3

Description LOOKING SOUTH TOWARD COSBY CAMPGROUND

PHOTO 4

Description WEST (UPSTREAM) SIDE

Culvert Inspection Report

Pictures

PHOTO 5

Description GENERAL TOPSIDE VIEW LOOKING NORTH; NOTE TYPICAL TRANSVERSE AND

LONGITUDINAL CRACKING OF ASPHALT PAVEMENT OVER STRUCTURE

PHOTO 6

Description TYPICAL TRANSVERSE AND LONGITUDINAL CRACKING OF ASPHALT PAVEMENT; SOUTH

APPROACH SHOWN

Culvert Inspection Report

Pictures

PHOTO 7

Description GENERAL UNDERSIDE VIEW LOOKING WEST, NORTH BARREL; NOTE TYPICAL

DETERIORATION OF BITUMINOUS COATING

PHOTO 8

Description GENERAL VIEW OF NORTH SIDE, NORTH BARREL; NOTE TYPICAL VEGETATION GROWTH

IN CHANNELS

Culvert Inspection Report

Pictures

PHOTO 9

Description GENERAL VIEW OF NORTH SIDE, SOUTH BARREL

PHOTO 10

Description TYPICAL RUSTING OF BARRELS NEAR BOTTOM; WEST END OF SOUTH BARREL ON

SOUTH SIDE SHOWN; ALSO NOTE TYPICAL EXPOSED FOOTINGS

Culvert Inspection Report

Pictures

PHOTO 11

Description TYPICAL BARREL CONNECTION BOLT NUTS NOT FULLY ENGAGED; EAST END OF NORTH

BARREL SHOWN

PHOTO 12

Description TYPICAL DRIFT IN BARRELS; SOUTH BARREL SHOWN

Culvert Inspection Report

Pictures

PHOTO 13

Description TYPICAL EXPOSED FOOTINGS; EAST END OF SOUTH BARREL AT NORTH SIDE SHOWN;

ALSO NOTE TYPICAL MOSS GROWTH ON FOOTINGS

PHOTO 14

Description UPSTREAM CHANNEL

Culvert Inspection Report

Pictures

PHOTO 15

Description DOWNSTREAM CHANNEL

File details come from the government source that posted it. Updated .