This is an architectural as-built drawing set for the Gateway Bar (BL-306) located in Terminal B Landside at Sacramento International Airport, prepared in January 2012 by House & Robertson Architects for SSP America, a food service design and management company. The comprehensive drawing set includes detailed plans for demolition, construction, floor layouts, ceiling plans, equipment placement, interior and exterior elevations, wall and storefront details, door schedules, and specific bar millwork and base details. The drawings cover a 1,704 square foot food and beverage venue designed to meet 2010 California building codes and airport terminal specifications, with specific attention to fire protection, accessibility, and environmental health requirements.
The project involves a tenant improvement for a food and beverage venue at Level 3 of the new Terminal B, featuring a bar and related service areas. The design incorporates specific construction requirements including Type I-B high-rise construction, fire-resistive ratings for structural elements, and compliance with California Green Building Standards Code. The drawings specify use of non-combustible materials, fire sprinkler protection, and detailed specifications for wall, ceiling, and floor finishes. The project team includes multiple specialized firms: SSP America as the client, SmartDesign Group for interior design, House & Robertson as executive architects, ME Engineers for engineering services, and CT (likely a technical consulting firm) for additional design support.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AS�BUILT
JANUARY 3, 2012
CLIENT
DESIGN
EXECUTIVE ARCHITECT
ENGINEERS
FOOD SERVICE CONSULTANTS
BL 306 � THE GATEWAY BAR
ABBREVIATIONS
GL
GL
GRAPHIC SYMBOLS
MATERIAL SYMBOLS
A-0.0
GENERAL INFORMATION
SHEET INDEX
04/01/11 FINAL SUBMITTAL
05/03/11 PERMIT SET
1 06/01/11 PLAN CHECK RESPONSE
REVISIONS
DATENO. DESCRIPTION
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
SCALE:
Up da ted
1/7 /20
P rin ted
1/7 /20
9:
:08
P M
B y:
a dm in Fil e:
G:
\10
S
MF
F oo d & B ev er ag e\3
_d wg s\G
AT
EW
AY
B L-
6\s he ets
\S
MF
-B L3
-S
SP
-G
AT
EW
AY
-A
.0.
0.d wg
Ta b:
La yo ut1
Sacramento County Airport System (SCAS) This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento
Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
M-E Engineers, Inc.
10055 west 43rd avenue wheat ridge, co 80033 www.me-engineers.com
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
BL - 306
GATEWAY BAR
1/3/12 AS-BUILT
COVER
ARCHITECTURAL
A0.0 SHEET INDEX/GENERAL INFORMATION
A1.0 CODE AND EXITING ANALYSIS/ENVIRONMENTAL HEALTH
A1.1 GENERAL NOTES/ACCESSIBILITY NOTES
A2.0 DEMOLITION PLAN
A2.1 CONSTRUCTION FLOOR PLAN
A2.2 REFLECTED CEILING PLAN
A2.3 FF&E PLAN
A2.4 FLOOR FINISH PLAN
A3.1 INTERIOR ELEVATIONS
A3.2 STOREFRONT ELEVATIONS
A4.1 INTERIOR SECTIONS
A4.2 CEILING SECTIONS AND DETAILS
A5.1 INTERIOR PARTITION DETAILS
A5.2 WALL/STOREFRONT DETAILS
A5.4 DOOR SCHEDULE AND DETAILS
A5.11 TYPICAL CEILING DETAILS
A5.12 TYPICAL CEILING DETAILS
A6.1 BAR MILLWORK DETAILS
A6.2 BAR MILLWORK DETAILS
A6.3 CUSTOM FURNISHING
MECHANICAL
M1.0 MECHANICAL LEGEND
M1.1 GENERAL NOTES
M1.2 MECHANICAL SCHEDULES AND CONTROL DIAGRAMS
M1.3 MECHANICAL TITLE 24
M1.4 MECHANICAL TITLE 24
M2.0 EXISTING PLAN
M2.1 CONSTRUCTION PLAN
M3.0 MECHANICAL DETAILS
PLUMBING
P1.0 LEGEND & ABBREVIATIONS
P1.1 PLUMBING SPECFICATIONS
P1.2 PLUMBING SCHEDULES
P2.1 PLUMBING PLAN
P2.2 PLUMBING BELOW SLAB PLAN
P3.0 PLUMBING DETAILS
ELECTRICAL
E1.0 ELECTRICAL LEGEND
E1.1 ELECTRICAL ONE-LINE
E1.2 FIXTURE SCHEDULE
E1.3 TITLE 24
E2.1 ELECTRICAL PLAN
E2.2 LIGHTING PLAN
E3.0 ELECTRICAL DETAILS
TECHNOLOGY
T1.0 TECHNOLOGY LEGEND
T2.1 TECHNOLOGY PLAN
T3.0 TECHNOLOGY DETAILS
DRAWING INDEX
VICINITY MAP
PROJECT DATA
G. SEPARATE PERMITS
SPRINKLER SYSTEM SHALL BE SUBMITTED SEPARATELY FOR
PERMITTING.
FIRE ALARM SHALL BE SUBMITTED SEPARATELY FOR PERMITTING.
SIGNAGE DRAWINGS SHALL BE SUBMITTED SEPARATELY FOR
AIRPORT APPROVAL.
H. LANDLORD'S REQUIRED SUB-CONTRACTORS
FIRE ALARMS & SPRINKLERS: COSCO FIRE PROTECTION
CONTACT: JEFF GREY, 559.275.3795
DATA CABLING: INTEGRITY DATA & FIBER (IDF)
6751 HILLS VIEW DR.
VACAVILLE, CA 95688
916.439.4787
ROOF PENETRATIONS: NATIONS ROOF
CONTACT: DOUG GOSSETT,
619.933.2410
I. LANDLORD'S PREFERRED SUB-CONTRACTOR:
BUILDING CONTROLS: L&H AIRCO
1905 AVIATION BLVD.
2530 WARREN DR.
ROCKLIN, CA 95677
916.677.1000
J. AIRPORT PROJECT COORDINATOR
SCOTT FUJIKAWA
916.874.0658
FUJIKAWAS@SACCOUNTY.NET
K. SLAB CORING
SCAN FLOOR (X-RAY OR EQUIVALENT) PRIOR TO PENETRATIONS
GREATER THAN 1" IN DEPTH. CONFIRM PROPOSED SCANNING
METHOD WITH AIRPORT AUTHORITY PRIOR TO ALL WORK.
KEY PLAN / AREA OF WORK
T3C07
T3B15
T3B19
T3D06
T3A08
T3A09B T3B21B
T3B18
T3AS03 T3AS04
FIDS FIDS
T3C01 T3D13
T3A28F
T3A28A
T3A28H
T3A28D
T3A28J
T3A28P
T3A28R
T3A28M
T3A28B
T3A28C
T3A28K
T3A28L
T3A28U T3A28V
T3A04
A. PROJECT ADDRESS:
SACRAMENTO INTERNATIONAL AIRPORT
6950 AIRPORT BOULEVARD WEST, SUITE BL-306
SACRAMENTO, CALIFORNIA 95837
B. PROJECT DESCRIPTION
TENANT IMPROVEMENT FOR FOOD & BEVERAGE VENUE AT LEVEL 3
OF THE NEW LANDSIDE TERMINAL B OF THE SACRAMENTO
AIRPORT.
C. AREA OF TENANT IMPROVEMENTS:
LEVEL 3: 1,704 SF
D. APPLICABLE CODES:
2010 CALIFORNIA BUILDING CODE
2010 CALIFORNIA MECHANICAL CODE
2010 CALIFORNIA ELECTRICAL CODE
2010 CALIFORNIA PLUMBING CODE
2010 CALIFORNIA ENERGY CODE AND THE 2008 BUILDING ENERGY
EFFICIENCY STANDARDS
2010 CALIFORNIA GREEN BUILDING STANDARDS CODE
NFPA 13 FIRE SPRINKLER 2010 EDITION
NFPA 72 FIRE ALARM 2010 EDITION
NFPA 415 AIRPORT TERMINALS 2008 EDITION
NFPA 10 FIRE EXTINGUISHERS 2007 EDITION
E. GENERAL CONSTRUCTION REQUIREMENTS:
CONSTRUCTION TYPE: TYPE I-B
HIGH RISE ANCHOR (CBC 503)
FIRE-RESISTIVE RATING REQUIREMENTS (TABLE 602):
PRIMARY STRUCTURAL FRAME: 2 HR.
BEARING WALLS: N/A
NON-BEARING WALLS (EXTERIOR): N/A
NON-BEARING WALLS (INTERIOR): 0 HR.
FLOOR CONSTRUCTION: 2 HR.
FIRESTOPPING AT PENETRATIONS
REQUIRED PER CBC 713.4.1
ROOF CONSTRUCTION: 1 HR.
COMBUSTIBLE MATERIALS LIMITED TO THOSE ALLOWED PER 603.
INTERIOR FINISH MATERIALS SHALL BE LIMITED TO CLASS A OR
CLASS B FLAMESPREAD INDEX, PER NFPA 415.
SEPARATION FROM ADJACENT TENANTS: 1 HR. PER CBC 402.7.2
AND 709
SEPARATION FROM MALL: 0 HR. PER CBC 402.7
F. PROPOSED OCCUPANCY GROUP:
GROUP A-2: ASSEMBLY USE INTENDED FOR FOOD AND/OR DRINK
CONSUMPTION
F. FIRE PROTECTION:
AUTOMATIC FIRE SPRINKLER PROTECTION SYSTEM SHALL BE
PROVIDED THROUGHOUT.
DESIGN CRITERIA: ORDINARY HAZARD GROUP 2; MIN. DENSITY
0.20GPM/SF PER NFPA 13.
FIRE ALARM SYSTEM PROVIDED BY BASE BUILDING SHALL BE
MODIFIED AS NECESSARY FOR COMPLIANCE WITH NFPA 72.
DRAWING INDEX (cont.)
FOOD SERVICE DRAWINGS
FS2.0 EQUIPMENT PLAN
FS3.0 ARCHITECTURAL REQUIREMENTS
FS4.0 ELECTRICAL SERVICES
FS5.0 PLUMBING SERVICES
FS6.0 ELEVATION TAGS
FS6.1 ELEVATIONS & DETAILS
FS6.2 ELEVATIONS & DETAILS
FS6.3 WALK-IN COOLER PLAN AND DETAILS
FS6.4 EQUIPMENT ELEVATIONS AND DETAILS
A-1.0
ENVIRONMENTAL HEALTH NOTES
CODE AND EXITING ANALYSIS
04/01/11 FINAL SUBMITTAL
05/03/11 PERMIT SET
REVISIONS
DATENO. DESCRIPTION
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
SCALE:
Up da ted
1/7 /20
P rin ted
1/7 /20
9:
:41
P M
B y:
a dm in Fil e:
G:
\10
S
MF
F oo d & B ev er ag e\3
_d wg s\G
AT
EW
AY
B L-
6\s he ets
\S
MF
-B L3
-S
SP
-G
AT
EW
AY
-A
.1.
0.d wg
Ta b:
La yo ut1
Sacramento County Airport System (SCAS) This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento
Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
M-E Engineers, Inc.
10055 west 43rd avenue wheat ridge, co 80033 www.me-engineers.com
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
BL - 306
GATEWAY BAR
1/3/12 AS-BUILT
CODE ANALYSIS AND EXITING
0506 05060708
ENVIRONMENTAL HEALTH INFORMATION
ROOM
FINISH SCHEDULE
SEATING AREA
BACKBAR
FOOD STORAGE
WALK-IN BOXES
FLOOR BASE WALLS CEILINGS
A-1.1
ACCESSIBILITY NOTES
GENERAL NOTES
04/01/11 FINAL SUBMITTAL
05/03/11 PERMIT SET
REVISIONS
DATENO. DESCRIPTION
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
SCALE:
Up da ted
1/7 /20
P rin ted
1/7 /20
9:
:18
P M
B y:
a dm in Fil e:
G:
\10
S
MF
F oo d & B ev er ag e\3
_d wg s\G
AT
EW
AY
B L-
6\s he ets
\S
MF
-B L3
-S
SP
-G
AT
EW
AY
-A
.1.
1.d wg
Ta b:
La yo ut1
Sacramento County Airport System (SCAS) This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento
Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
M-E Engineers, Inc.
10055 west 43rd avenue wheat ridge, co 80033 www.me-engineers.com
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
BL - 306
GATEWAY BAR
1/3/12 AS-BUILT
GENERAL NOTES
1. GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS SHALL REVIEW
THE REQUIREMENTS CONTAINED WITHIN SECTION 5 OF THE LANDLORD'S
"TENANT DESIGN MANUAL FOR SACRAMENTO INTERNATIONAL AIRPORT"
DATED JANUARY 8, 2010, AND THE "SUPPLEMENT TO THE TENANT DESIGN
MANUAL - PRIOR TO DATE OF BENEFICIAL OCCUPANCY", DATED
JANUARY 8, 2010. REQUIREMENTS CONTAINED WITHIN THESE
DOCUMENTS SHALL BE CONSIDERED PART OF THE CONSTRUCTION
DOCUMENTS FOR THIS PROJECT.
2. ALL SUB-CONTRACTORS SHALL VISIT THE SITE PRIOR TO BIDDING OR
AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS
CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR
FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS.
3. SUB-CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR
OWNER PRIOR TO BIDDING, FOR INTERPRETATIONS AND
CLARIFICATIONS OF THE DESIGN, AND INCLUDE IN HIS BID ALL COSTS TO
MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT,
ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE
IMPLEMENTED AT CONTRACTOR'S COST.
4. BIDDING SUB-CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE
OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS
THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH
GOVERNING CODES, THE PLANS, AND SPECIFICATIONS. THE
CONTRACTOR SHALL NOTIFY THE ARCHITECT, ENGINEER OR OWNER OF
ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND
DESIGN INTENT.
5. SITE VISITS ARE MANDATORY BY ALL CONTRACTOR AND
SUB-CONTRACTORS. ALL CONTRACTORS AND SUBS ARE RESPONSIBLE
FOR KNOWLEDGE OF EXISTING SITE CONDITIONS AT THE TIME OF
BIDDING / PROJECT COMMENCEMENT. FAILURE TO RECOGNIZE WORK
REQUIRED BY NEW SCOPE SHALL BE AT THE EXPENSE OF THE
SUB-CONTRACTOR. ALSO, G.C. AND SUB-CONTRACTORS ARE TO
FAMILIARIZE THEMSELVES WITH LANDLORD'S SITE ACCESS, RULES, AND
REGULATIONS.
6. THE MECHANICAL, AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY
TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS
BEFORE THE INSTALLATION OF STRUCTURAL, MECHANICAL &
ELECTRICAL WORK. SHOULD THERE BE A DISCREPANCY BETWEEN THE
ARCHITECTURAL DRAWINGS AND THE CONSULTING ENGINEERS'
DRAWINGS THAT WOULD CAUSE AND AWKWARD INSTALLATION, IT SHALL
BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION
PRIOR TO INSTALLATION OF SAID WORK. ANY WORK INSTALLED IN
CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED
BY THE CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST TO
THE OWNER OR ARCHITECT.
7. DO NOT SCALE DRAWINGS. GENERAL CONTRACTOR SHALL VERIFY
ALL DIMENSIONS AND CONDITIONS AT SITE PRIOR TO COMMENCING THE
WORK, AND REPORT ANY DISCREPANCIES TO THE ARCHITECT IN
WRITING. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN
ON DRAWINGS. CONTRACTOR SHALL NOTIFY ARCHITECT WHERE
DISCREPANCIES OCCUR BETWEEN DRAWINGS, GENERAL NOTES AND
SPECIFICATIONS.
8. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE
CONSIDERED TO BE CONSTRUCTION STANDARDS. IF THE CONTRACTOR
HAS QUESTIONS REGARDING SAME, OR THEIR EXACT MEANING, THE
ARCHITECT SHALL BE NOTIFIED FOR CLARIFICATION.
9. ALL DIMENSIONS ARE TO FACE OF WALL FINISH UNLESS OTHERWISE
NOTED.
10. FINISH FLOOR ELEVATIONS ARE NOMINAL. VARIATIONS ARE
EXPECTED DUE TO EXISTING CONDITIONS. THRESHOLD DETAILS AND
FLOOR SLOPES INDICATE MIN. AND MAX. DIMENSIONS PER CODE
REQUIREMENTS. DO NOT EXCEED THE MIN. OR MAX. DIMENSIONS, AND
NOTIFY ARCHITECT IF EXISTING CONDITIONS PRECLUDE THIS.
11. CEILING HEIGHT DIMENSIONS ARE TO FINISHED SURFACES.
12. ALL CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF
THE APPLICABLE CODES LISTED ON A-0.0.
13. FIRE PROTECTION FACILITIES, INCLUDING ACCESS, MUST BE
PROVIDED PRIOR TO AND DURING THE CONSTRUCTION PERIOD AS
REQUIRED BY THE AIRPORT FIRE DEPARTMENT.
14. CONTRACTOR SHALL PROVIDE TEMPORARY EXIT SIGNS TO ASSURE A
MEANS OF EGRESS DURING CONSTRUCTION.
15. GENERAL CONTRACTOR SHALL COORDINATE PLUMBING, DRAINAGE,
ELECTRICAL, TELEPHONE WORK WITH BASE BUILDING UTILITIES TO
PROVIDE A COMPLETE OPERATING BASE BUILDING SYSTEM.
16. CONTRACTOR SHALL VERIFY ALL OPENINGS IN THE FIELD PRIOR TO
THE FABRICATION OF DOORS AND FRAMES.
17. DOOR OPENINGS IN GYPSUM BOARD PARTITIONS NOT DIMENSIONED
ARE TO BE LOCATED WITHIN 6" OF ADJOINING PARTITIONS.
18. ALL DOOR SIZES SHOWN ON DOOR SCHEDULE ARE OPENING SIZES.
ALLOWANCES FOR THRESHOLDS, ETC. SHALL BE DEDUCTED. FRAMES
SHALL BE REINFORCED WHERE REQUIRED FOR CLOSERS, STOPS AND
HARDWARE.
19. PROVIDE EXIT SIGNS AND DIRECTIONAL SIGNS WITH MINIMUM 6" HIGH
BY ¾" STROKE CLOCK LETTERS ON A CONTRASTING BACKGROUND. SEE
ENLARGED FLOOR PLANS REFLECTED CEILING PLANS FOR EXIT SIGN
LOCATIONS.
20. ANY DECORATIONS USED SHALL BE NON-COMBUSTIBLE OR
FLAME-RETARDANT TREATED IN AN APPROVED MANNER.
21. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT. THE
SPRINKLER SYSTEM SHALL BE APPROVED BY BUILDING DIVISION & FIRE
DEPT. PRIOR TO INSTALLATION / SEPARATE PERMIT REQ'D.
22. ALL BUILDING SIGNAGE WILL BE SUBMITTED SEPARATELY.
23. EXIT DOOR WIDTH AND HEIGHT SHALL COMPLY WITH CALIFORNIA
BUILDING CODE SECTION 1008.1.1: THE MINIMUM WIDTH OF EACH DOOR
OPENING SHALL BE SUFFICIENT FOR THE OCCUPANT LOAD THEREOF
AND SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES.
24. EXIT DOOR FLOOR LEVELS SHALL COMPLY WITH CALIFORNIA
BUILDING CODE SECTION 1008.1.5.
25. PROVIDE LEVEL FLOOR DEPRESSION, (FREE OF PROJECTED
AGGREGATE), INSULATION AND FINISHED FLOOR FOR ENTIRE AREA OF
COLD STORAGE ROOMS, TO ALLOW LEVEL FLOOR THRESHOLD AT
DOORS. ALSO PROVIDE SETTING BEDS AND RUN FINISHED FLOORS,
BASES, AND CURBS WHERE INDICATED. INSULATION, EXPANSION JOINTS
AND FINISHED FLOOR IN PREFABRICATED REFRIGERATORS AND
FREEZERS AS INDICATED IN DRAWINGS.
26. FURNISH AND INSTALL FLOORS IN KITCHEN AND RELATED WET
AREAS THAT ARE SLIP RESISTANT AND ARE EASILY MAINTAINED. SEE
FINISH SPECIFICATION BOOKLET FOR FLOORING MATERIAL.
27. THESE AREAS SHALL BE PROVIDED WITH WATERPROOF FLOOR
MEMBRANE. QUARRY TILE TO BE 100% NON-SLIP TYPE (CARBORUNDUM
ADDITIVE). GROUTING FOR QUARRY TILE FLOORS IN FOOD
PREPARATION AREAS SHALL BE EPOXY TYPE. GROUT COLOR TO MATCH
TILE IS RECOMMENDED. FURNISH AND INSTALL BASES, INTEGRAL WITH
FLOORS, WITH COVERED CORNERS.
28. VERIFY SUBSTRATE CONDITIONS ARE ACCEPTABLE FOR PRODUCT
INSTALLATION IN ACCORDANCE WITH MANUFACTURE'S INSTRUCTIONS.
REMOVE RIDGES AND BUMPS. APPLY SUBFLOOR FILLER (GREY
PORTLAND CEMENT-BASED UNDERLAYMENTS AND PATCHING
COMPOUNDS) TO LOW SPOTS AND CRACKS TO ACHIEVE FLOOR LEVEL
OR DESIGNATED SLOPE TO A TOLERANCE OF 1/8" OVER 10', ALLOW TO
CURE. ENSURE CONCRETE SLOPES TO DRAINS AND OTHER FLOOR
SINKS. REMOVE DUST, OLD ADHESIVES, PAINT, DIRT, WAX, SEALER AND
FOREIGN MATTER FROM EXISTING SURFACES PRIOR TO ANY WORK
COMMENCING.
29. DRAINS: FIT WATERPROOF MEMBRANE AND MECHANICALLY FASTEN
TO DRAIN OUTLETS TO ENSURE A PERMANENT, WATERTIGHT
INSTALLATION.
30. NEW ROUND DRAINS: INSTALL ROUND FLASH CLAMPING RING TYPE
DRAINS TO ACCOMMODATE FLOORING. INSTALL DRAINS TO FIT FLUSH
WITH SURROUNDING FLOOR SURFACE. PLEASE REFER TO
MANUFACTURER'S CURRENT INSTALLATION GUIDE FOR APPROVED
DRAIN MANUFACTURERS AND STYLES.
31. SQUARE AND RECTANGULAR DRAINS AND FLOOR SINKS: INSTALL A
GULLY EDGE AROUND PERIMETER OF DRAIN WHICH HAS BEEN SET IN
CONCRETE IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION
GUIDE. DO NOT USE GULLY EDGE AROUND DRAINS SET IN WOOD
FLOORS. PROVIDE STAINLESS STEEL STRIPS, MECHANICALLY FASTENED
WITH STAINLESS STEEL SCREWS. USE STAINLESS STEEL STRIPS IN
OTHER AREAS WHERE IT IS NOT PRACTICAL TO USE A GULLY EDGE.
32. NOTE: KITCHEN FLOOR SHOULD BE CLEANED AND SEALED PRIOR TO
PLACEMENT OF FOOD SERVICE EQUIPMENT.
33. ALL FLOORS TO BE PITCHED TO ALL AREA FLOOR DRAINS AND
TROUGHS TO ENSURE ELIMINATION OF STANDING WATER AND
ADEQUATE DRAINAGE OF FLOOR.
34. CEILING AND WALL SURFACES ADJACENT TO, OR OVER, ANY FOOD
PREPARATION AREA, INCLUDING KITCHENS, SERVICE AREAS, BARS, ETC.
MUST BE SMOOTH, EASILY CLEANABLE AND LIGHT IN COLOR. LAY-IN
CEILING TILE, IF USED, MUST BE NON-POROUS AND NON-FISSURED. IN
AREAS OF MOIST CONDITIONS WALL SHALL BE CONSTRUCTED OF
WATERPROOF (GREEN) GYPBOARD, WONDERBOARD OR SIMILAR, WITH
AN IMPERVIOUS AND CLEANABLE ARCHITECTURAL FINISH. IN VERY WET
OR COMBUSTIBLE CONDITIONS, WALLS SHALL BE CONSTRUCTED OF
WONDERBOARD WITH AN IMPERVIOUS AND CLEANABLE ARCHITECTURAL
FINISH AND COVERED FULL HEIGHT WITH FIBERGLASS REINFORCED
PLASTIC PANELLING 3/32" (2.38MM) THICK, OR SIMILAR, WITH LOW SMOKE
AND LESS THAN 25 FLAME SPREAD RATING. PANELLING SHALL BE
APPLIED WITH A FULL BED ADHESIVE PER THE MANUFACTURER'S
RECOMMENDATIONS. COLOR AS SELECTED. PANELING SHALL BE
OMITTED WHERE STAINLESS STEEL WALL FLASHING IS SPECIFIED TO BE
FURNISHED BY THE FOODSERVICE EQUIPMENT CONTRACTOR.
35. ALL WALLS IN CONTACT WITH, OR WITHIN 6" (150MM) OF RANGES,
FRYERS, BROILERS AND/OR OVENS SHALL BE CONSTRUCTED OF
NON-COMBUSTIBLE HEAT-PROOF MATERIALS.
36. EXTERNAL WALLS OR COLUMN CORNERS IN KITCHENS AND RELATED
AREAS, NOT PROVIDED WITH DOORS OR PROTECTED BY FIXED
EQUIPMENT, SHALL BE PROVIDED WITH CONSTRUCTION SPECIALTIES
INC. MODEL SM-20 ACROVYN OR SIMILAR, 4'-1" (1250MM) HIGH OVERALL
CORNER GUARD, COMPLETE WITH TOP AND BOTTOM CAPS AND
ALUMINUM RETAINER OR BY FOODSERVICE CONTRACTOR WHEN
SPECIFIED. COORDINATE COLOR WITH ADJACENT SURFACES.
37. AT AREAS ABOVE HOODS AND VENTILATORS AND COOKING OR
BAKING EQUIPMENT EXHAUST DUCTS, FLUES OR VENTS, PROVIDE
FIRE-RATED MATERIALS PER CODE REQUIREMENTS.
38. PROVIDE FIRE RATED ENCLOSURE IN ACCORDANCE WITH CODE
REQUIREMENTS AT VENTILATORS AND GREASE EXHAUST DUCTS.
39. FURNISH AND INSTALL ANGLE CHANNEL OR Z-BAR FRAMING FOR
VENTILATORS, CONDENSATE HOOD, POT RACKS, COLD STORAGE
ROOMS AND SERVICE BAR CABINETS. FOODSERVICE EQUIPMENT
CONTRACTOR SHALL FURNISH AND INSTALL HANGERS FROM KITCHEN
EQUIPMENT TO FRAMING.
40. FURNISH AND INSTALL ANCHOR BOLTS AS INDICATED, IN
ACCORDANCE WITH SHOP DRAWINGS.
41. PROVIDE AND INSTALL WALL REINFORCEMENTS OF BACKING AS
REQUIRED FOR INSTALLATION OF BRACKETS OR GUSSETS TO SUPPORT
EQUIPMENT FURNISHED AND INSTALLED BY FOODSERVICE EQUIPMENT
CONTRACTOR. REFER TO FOODSERVICE ARCHITECTURAL
REQUIREMENTS DRAWINGS FOR LOCATION.
42. INSTALL WALL CARRIERS FOR CANTILEVER EQUIPMENT SUPPORT AS
PROVIDED BY FOODSERVICE EQUIPMENT CONTRACTOR.
43. DOOR VISION PORTS (GLAZED) IN THE KITCHEN WHERE REQUIRED
SHALL BE AT A HEIGHT FOR EASY VISION.
44. DOOR KICK PLATES WHERE REQUIRED 36" (915MM) HIGH.
45. FIRE EXTINGUISHERS IN THE KITCHEN AREA TO BE LOCATED
ACCORDING TO LOCAL CODE.
46. WHERE PREFABRICATED WALK-IN COOLERS, OR WHEEL-IN
REFRIGERATORS APPEAR, DELETE ALL BASEBOARDS. IF SPECIFIED,
INSTALL COVED BASEBOARD ALONG THE INTERIOR AND EXPOSED
EXTERIOR WALK IN COOLER WALL PANELS. COORDINATE INSTALLATION
WITH FOOD SERVICE EQUIPMENT CONTRACTOR.
47. FLOOR DRAINS WHERE SHOWN ON DRAWINGS AS WELL AS ANY
DEEMED NECESSARY FOR HOUSEKEEPING PURPOSES. EXPOSED FLOOR
DRAINS AT POSITIONS INDICATED ARE INTENDED TO BE APPROXIMATELY
8-1/2" (216MM) SQUARE UNLESS OTHERWISE INDICATED, SMITH, ZURN OR
EQUAL, WITH POLISHED NICKEL BRONZE GRATE AND ACID RESISTING
ENAMEL INTERIOR. INSTALL FOR POSITIVE DRAINAGE OF FLOOR IN ALL
WET AREAS.
48. FOODSERVICE EQUIPMENT CONTRACTOR TO PROVIDE DISPOSER
UNITS COMPLETE WITH MIXING VALVE, OVERHEAD SPRAY ASSEMBLY,
CHECK VALVES, SOLENOID VALVE, FLOW CONTROL VALVE AND VALVE
BREAKER. THE PLUMBING CONTRACTOR TO INTERCONNECT ALL
COMPONENTS FOR THE WASTE DISPOSERS. FURNISH SHUT OFF VALVES,
INTERCONNECTING PIPING AND MAKE FINAL CONNECTIONS.
49. CAP OFF ALL "FUTURE" SERVICES.
50. GENERAL WATER PRESSURE IN KITCHEN AREA SHOULD BE AT
MINIMUM 40 PSIG (276 KPA) AND NOT TO EXCEED 60 PSIG (414 KPA)
MAXIMUM. WATER PRESSURE FOR DISHWASHER AND/OR GLASS
WASHER TO BE 25 PSIG (172 KPA) MAXIMUM.
51. EQUIPMENT REQUIRING WATER PRESSURE ABOVE THIS WILL BE
FITTED WITH A LOW WATER PRESSURE BOOSTER SYSTEM SUPPLIED BY
THE EQUIPMENT SUPPLIER/PURVEYOR.
52. CONSTANT 140°F (60°C) HOT WATER IS REQUIRED FROM BUILDING
SUPPLY.
53. EQUIPMENT SINKS ARE PROVIDED WITH A 2" (50MM) WASTE
CONNECTION. PLUMBER TO PROVIDE AND INSTALL TAIL PIECES FOR
SINKS THAT ARE CHROME PLATED FLARED BRASS TUBING FOR
CONNECTION TO I.P.S. MALE THREAD FITTINGS, AS NOTED. "P" TRAPS
SHALL BE CHROME PLATED ADJUSTABLE BRASS, UNIFORM CODE
PATTERN.
54. ALL FLOOR SINKS AND FLOOR DRAINS SHALL BE PROVIDED WITH
DOME BOTTOM STRAINER, DEEP SEAL TRAP AND CLEAN-OUT FLUSH
WITH FINISHED FLOOR.
55. EXPOSED FLOOR SINKS SHALL BE SQUARE TYPE INDIRECT WASTE
RECEPTOR, SMITH, ZURN OR EQUAL, WITH DOME BOTTOM STRAINER,
POLISHED NICKEL BRONZE RIM, FULL GRATE, FUNNEL AND ACID
RESISTING ENAMEL INTERIOR. INSTALL FLUSH WITH FINISHED FLOOR OR
AS REQUIRED BY CODE.
56. ALL SINK WASTES, DIRECT OR INDIRECT, AND WASTES FROM
WATER-WASH TYPE VENTILATORS SHALL BE FURNISHED AND INSTALLED
BY THE PLUMBER, INCLUDING WASTES FROM SINKS BUILT INTO ANY
STANDARD OR ESPECIALLY FABRICATED EQUIPMENT. ALL INDIRECT
WASTE, EXCEPT SINKS AND VENTILATORS, SHALL BE THE
RESPONSIBILITY OF THE FOODSERVICE EQUIPMENT CONTRACTOR.
WASTES WITHIN FIXTURES SHALL BE ROUTED TO CONFORM WITH
INTERIOR SHELVES, SPACES OR STRUCTURES.
57. INDIRECT WASTES SHALL BE ADEQUATE SIZE AND EXTENDED FROM
DRAIN TO FLOOR SINK.
58. DRAINS FROM SINKS BUILT INTO ANY STANDARD OR ESPECIALLY
FABRICATED EQUIPMENT BY FOODSERVICE EQUIPMENT CONTRACTOR.
A. ACCESSIBILITY FOR GROUP A OCCUPANCIES. DINING, BANQUET AND
BAR FACILITIES
1. ALL DINING AREAS, INCLUDING RAISED OR SUNKEN DINING AREAS,
LOGGIAS, OUTDOOR SEATING AREAS, AND ALL AREAS WHERE EACH
TYPE OF FUNCTIONAL ACTIVITY OCCURS SHALL BE ACCESSIBLE.
2. WHEELCHAIR ACCESS IS PROVIDED TO EACH TYPE OF FUNCTIONAL
ACTIVITY IN THE FACILITY.
3. AT LEAST 5%, BUT NOT LESS THAN ONE OF THE SEATING SPACES IN
EACH FUNCTIONAL AREA IS ACCESSIBLE AS FOLLOWS:
a. MINIMUM 30" x 48" CLEAR FLOOR SPACE IS PROVIDED.
b. ONE FULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR SPACE
ADJOINS OR OVERLAPS AN ACCESSIBLE ROUTE OR ANOTHER
WHEELCHAIR CLEAR FLOOR SPACE.
c. KNEE SPACE AT TABLES IS AT LEAST 27" HIGH, 30" WIDE AND 19"
DEEP
d. HEIGHT OF TABLES IS BETWEEN 28" -34" FROM THE FLOOR OR
GROUND.
4. ACCESS TO ACCESSIBLE SEATING SPACE(S) IS PROVIDED BY MAIN
AISLES A MINIMUM OF 36" IN WIDTH.
5. EQUIVALENT SERVICES AND DÉCOR ARE PROVIDED AT ACCESSIBLE
SEATING SPACES AS FOR THE GENERAL PUBLIC.
6. ACCESSIBLE SEATING SPACES ARE INTEGRATED WITH GENERAL
SEATING AND ALLOW A REASONABLE SELECTION OF SEATING AREA AND
AVOID HAVING ONE AREA SPECIFICALLY HIGHLIGHTED AS THE AREA FOR
PERSONS WITH DISABILITIES.
7. WHERE FOOD OR DRINK IS SERVED AT COUNTERS EXCEEDING 34" IN
HEIGHT FOR CONSUMPTION BY COSTUMERS SEATED OR STANDING AT
THE COUNTER, A PORTION OF THE MAIN COUNTER WHICH IS 60"
MINIMUM IN LENGTH IS PROVIDED THAT HAS THE FOLLOWING:
a. TOP OF COUNTER IS BETWEEN 28" - 34" ABOVE THE FINISH
FLOOR.
b. KNEE CLEARANCE A MINIMUM 27" HIGH, 30" WIDE AND 19" DEEP.
c. CLEAR FLOOR SPACE A MINIMUM OF 30" BY 48".
d. CLEAR FLOOR SPACE ADJOINS AN ACCESSIBLE ROUTE.
8. MINIMUM CLEAR WIDTH OF 36" IS PROVIDED.
9. TRAY SLIDES ARE MOUNTED A MAXIMUM OF 34" ABOVE FLOOR.
10. 50% OF EACH TYPE OF SELF SERVICE SHELVES ARE WITHIN
REQUIRED
REACH RANGES, 54" MAXIMUM HEIGHT, SIDE REACH.
11. TABLEWARE, DISHWARE, CONDIMENTS, FOOD AND BEVERAGE
DISPLAY SHELVES, AND DISPENSING DEVICES ARE LOCATED WITHIN
ACCESSIBLE REACH RANGES.
12. TABLE TOPS AND COUNTERS ON WHICH TABLEWARE, CONDIMENTS,
ETC. ARE PLACES ARE BETWEEN 28" AND 34" FROM THE FLOOR
SURFACE.
13. ACCESS TO FOOD PREPARATION AREAS SHALL COMPLY WITH THE
PROVISIONS FOR ENTRANCE DOORS, DOORWAYS, AND AISLES.
NOTE: EMPLOYEE-ONLY AREAS MUST BE DESIGNED TO PROVIDE
ACCESS INTO, THROUGH AND OUT OF THE AREA(S).
B. ACCESSIBILITY FOR GROUP M OCCUPANCIES
1. GENERAL SALES, DISPLAY AND OFFICE AREAS SHALL BE MADE
ACCESSIBLE.
2. SALES EMPLOYEES WORK STATIONS SHALL BE LOCATED ON
ACCESSIBLE LEVELS, AND THE CUSTOMER SIDE OF SALES OR
CHECKOUT STATIONS SHALL BE ACCESSIBLE. EMPLOYEE WORK AREAS
SHALL BE SIZED AND ARRANGED TO PROVIDE ACCESS TO EMPLOYEES IN
WHEELCHAIRS.
3. SHELVES OR DISPLAY UNITS ALLOWING SELF-SERVICE BY
CUSTOMERS IN MERCANTILE OCCUPANCIES SHALL BE LOCATED ON AN
ACCESSIBLE ROUTE.
4. IN NEW CONSTRUCTION, CHECK STANDS, INCLUDING SERVICE
COUNTERS REQUIRING A SURFACE FOR TRANSACTIONS, SHALL BE MADE
ACCESSIBLE BY PROVIDING A 36" MINIMUM CLEAR AISLE WIDTH ON THE
CUSTOMER SIDE OF THE CHECK STAND.
5. IN NEW AND EXISTING CONSTRUCTION, ACCESSIBLE CHECK STANDS
SHALL PROVIDE A MINIMUM CLEAR CHECKOUT AISLE WIDTH OF 36" WITH
A MAXIMUM ADJOINING COUNTER HEIGHT NOT EXCEEDING 38" ABOVE
THE FINISH FLOOR. THE TOP OF THE COUNTER SLIP SHALL NOT EXCEED
40" ABOVE THE FINISH FLOOR.
C. EMPLOYEE WORK AREAS & WORK STATIONS
1. GENERAL EMPLOYEE AREAS ARE "THOSE AREAS COMMONLY USED BY
MULTIPLE EMPLOYEES, SUCH AS RESTROOM, BREAK ROOMS,
CONFERENCE AND MEETING SPACE, ETC.". EVEN WHEN THESE AREAS
ARE RESTRICTED FOR EMPLOYEE USE ONLY, THEY MUST COMPLY WITH
TITLE 24 ACCESSIBILITY REQUIREMENTS.
2. SPECIFIC WORK STATIONS ARE INTENDED TO MEAN "PLACES WHERE
INDIVIDUALS DO THEIR WORK, SUCH AS A CHEF'S CHOPPING BLOCK IN A
COMMERCIAL RESTAURANT OR A COMPUTER TERMINAL IN AN OFFICE".
THESE WORK STATIONS ARE NOT REQUIRED TO BE ACCESSIBLE
THEMSELVES, EXCEPT THAT AISLE AND FLOOR AND LEVEL
REQUIREMENTS MUST BE MET AND ENTRYWAYS MUST BE AT LEAST 32"
IN CLEAR WIDTH.
3. SPECIFIC WORK STATIONS, WITH THE EXCEPTION OF WORK STATIONS
IN SALES FACILITIES, CHECKSTANDS, TICKET BOOTHS, AND OTHER
WORK STATIONS WITH SPECIFIC REQUIREMENTS CONTAINED IN OTHER
PORTIONS OF THE REGULATIONS, NEED ONLY COMPLY WITH AISLE
WIDTH AND FLOORS AND LEVELS, AND ENTRYWAYS SHALL BE 32" IN
CLEAR WIDTH.
4. EMPLOYEE WORK AREAS SHALL BE ACCESSIBLE BY MEANS OF A 36"
MINIMUM AISLE AND A 32" MINIMUM CLEAR OPENING DOOR WIDTH.
5. EMPLOYEE AREAS SHALL CONFORM TO ALL REQUIREMENTS OF THE
DIVISION OF THE STATE ARCHITECT/ACCESS COMPLIANCE SECTION ON
THE CALIFORNIA BUILDING CODE, PLUMBING CODE, AND ELECTRICAL
CODE.
D. FLOORS & LEVELS
1. LEVEL AREA IS DEFINED AS "A SPECIFIED SURFACE THAT DOES NOT
HAVE A SLOPE IN ANY DIRECTION EXCEEDING ¼ INCH IN ONE FOOT
FROM THE HORIZONTAL (2.038% GRADIENT)".
2. IN BUILDING FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A
COMMON LEVEL THROUGHOUT, OR SHALL BE CONNECTED BY
PEDESTRIAN RAMPS, PASSENGER ELEVATORS, OR SPECIAL ACCESS
LIFTS.
3. GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN
ACCESSIBLE ROOMS AND SPACES, INCLUDING FLOORS, WALKS, RAMPS,
STAIRS, AND CURB RAMPS, SHALL BE STABLE, FIRM, AND
SLIP-RESISTANT.
4. CHANGE IN LEVEL UP TO ¼" MAY BE VERTICAL AND WITHOUT EDGE
TREATMENT.
5. CHANGES IN LEVEL BETWEEN ¼" AND ½" SHALL BE ACCOMPLISHED BY
A MEANS OF A RAMP NO STEEPER THAN 1 VERTICAL TO 2 HORIZONTAL.
6. IF CARPET OR CARPET TILE IS USED ON A GROUND OR FLOOR
SURFACE, IT SHALL BE SECURELY ATTACHED; HAVE A FIRM CUSHION,
PAD OR BACKING OR NO CUSHION OR PAD; AND HAVE A LEVEL LOOP,
TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL CUT / UNCUT PILE
TEXTURE. THE MAXIMUM PILE HEIGHT SHALL BE ½". EXPOSED EDGES OF
CARPET SHALL BE FASTENED TO FLOOR SURFACES AND HAVE TRIM
ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE. CARPET EDGE
TRIM SHALL COMPLY WITH SECTION 1124B.2.
E. DOORS
1. EVERY REQUIRED EXIT DOORWAY SHALL BE OF A SIZE AS TO PERMIT
THE INSTALLATION OF A DOOR NOT LESS THAN 3 FEET IN WIDTH AND
NOT LESS THAN 6 FEET 8 INCHES IN HEIGHT.
2. EXIT DOOR IS CAPABLE OF OPENING A MINIMUM OF 90 DEGREES.
3. THE CLEAR WIDTH OF THE DOORWAY IS 32" MINIMUM.
NOTE: FOR HINGED DOORS, THE OPENING WIDTH SHALL BE MEASURED
WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS
CLOSED POSITION.
4. DOUBLE DOORS/AUTOMATIC DOORS - AT LEAST ONE DOOR MUST
COMPLY WITH ITEMS 2 AND 3 ABOVE.
5. BOTTOM 10" OF DOOR (EXCEPT AUTOMATIC OR SLIDING DOORS) HAS A
SMOOTH, UNINTERRUPTED SURFACE THAT ALLOWS DOOR TO BE
OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR
HAZARDOUS CONDITION.
NOTE: WHERE NARROW DOOR FRAMES ARE USED, A 10-INCH-HIGH
SMOOTH PANEL MUST BE INSTALLED ON THE PUSH SIDE OF THE DOOR,
WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR
FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION.
F. CLEAR SPACE AT DOORS
1. REGARDLESS OF THE OCCUPANT LOAD, THERE SHALL BE A FLOOR OR
LANDING ON EACH SIDE OF A DOOR.
2. LEVEL AREA IN THE DIRECTION OF THE DOOR SWING IS A MINIMUM OF
60" IN LENGTH.
3. LEVEL AREA OPPOSITE THE DIRECTION OF THE DOOR SWING IS A
MINIMUM OF 44-48" IN LENGTH, DEPENDENT UPON DIRECTION OF
APPROACH AND EXISTENCE OF LATCH AND CLOSER.
4. SURFACE SLOPES OF THE LEVEL AREA DOES NOT EXCEED 1:50
GRADIENT (2%).
G. AISLES
1. EVERY PORTION OF EVERY BUILDING IN WHICH ARE INSTALLED SEATS,
TABLES, MERCHANDISE, EQUIPMENT OR SIMILAR MATERIALS SHALL BE
PROVIDED WITH AISLES LEADING TO AN EXIT.
2. ALL AISLES SERVING ONE SIDE ARE A MINIMUM OF 36" IN WIDTH.
3. ALL AISLES SERVING BOTH SIDES A RE A MINIMUM OF 44" IN WIDTH.
H. SPACE ALLOWANCE & REACH RANGES
1. THE MINIMUM CLEAR FLOOR OR GROUND SPACE REQUIRED TO
ACCOMMODATE A SINGLE, STATIONARY WHEELCHAIR AND OCCUPANT IS
30" BY 48". (THE MINIMUM FLOOR OR GROUND SPACE SHALL BE
INCREASED TO 42" BY 48" WHEN SUCH SPACE IS PERPENDICULAR TO AN
ADJACENT SEATING SPACE). THE MINIMUM CLEAR FLOOR OR GROUND
SPACE FOR WHEELCHAIRS MAY BE POSITIONED FOR FORWARD OR
PARALLEL APPROACH TO AN OBJECT. CLEAR FLOOR OR GROUND SPACE
FOR WHEELCHAIRS MAY BE PART OF THE KNEE SPACE REQUIRED
UNDER SOME OBJECT.
2. ONE DULL UNOBSTRUCTED SIDE OF THE CLEAR FLOOR OR GROUND
SPACE FOR A WHEELCHAIR SHALL ADJOIN OR OVERLAP AN ACCESSIBLE
ROUTE OR ADJOIN ANOTHER WHEELCHAIR CLEAR FLOOR SPACE. IF A
CLEAR FLOOR OR GROUND SPACE FOR A WHEELCHAIR IS LOCATED IN
AN ALCOVE OR OTHERWISE CONFINED ON ALL OR PART OF THREE
SIDES, ADDITIONAL MANEUVERING CLEARANCES SHALL BE PROVIDED.
3. THE SPACE REQUIRED FOR A WHEELCHAIR TO MAKE A 180 DEGREE
TURN IS A CLEAR SPACE OF 60" DIAMETER OR A T-SHAPED SPACE.
4. THE MINIMUM CLEAR WIDTH REQUIRED FOR A WHEELCHAIR TO TURN
AROUND AN OBSTRUCTION SHALL BE 36" WHERE THE OBSTRUCTION IS
48" OR MORE IN LENGTH AND 42" AND 48" WHERE THE OBSTRUCTION IS
LESS THAN 48" IN LENGTH.
5. THE MINIMUM CLEAR WIDTH FOR SINGLE WHEELCHAIR PASSAGE
SHALL BE 32" AT A POINT (24" MAXIMUM LENGTH) AND 36"
CONTINUOUSLY.
6. THE MINIMUM WIDTH FOR TWO WHEELCHAIRS TO PASS IS 60".
7. IF THE CLEAR FLOOR SPACE ONLY ALLOWS FORWARD APPROACH TO
AN OBJECT, THE MAXIMUM HIGH FORWARD REACH ALLOWED SHALL BE
48". THE MINIMUM LOW FORWARD REACH IS 15".
8. IF THE CLEAR FLOOR SPACE ALLOWS PARALLEL APPROACH BY A
PERSON IN A WHEELCHAIR, THE MAXIMUM HIGH SIDE REACH ALLOWED
SHALL BE 54" AND THE LOW SIDE REACH SHALL BE NO LESS THAN 9"
ABOVE THE FLOOR AS SHOWN IN FIGURES 11B-5D(a) & (b). IF THE SIDE
REACH IS OVER AN OBSTRUCTION, THE REACH AND CLEARANCES SHALL
BE AS SHOWN IN FIGURE 11B-5D(c).
ACCESSIBILITY NOTES
7.87 8.4
D
E
REVISIONS
DATENO. DESCRIPTION
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
SCALE:
Up da ted
1/7 /20
P rin ted
1/7 /20
9:
:37
P M
B y:
a dm in Fil e:
G:
\10
S
MF
F oo d & B ev er ag e\3
_d wg s\G
AT
EW
AY
B L-
6\s he ets
\S
MF
-B L3
-S
SP
-G
AT
EW
AY
-A
.2.
0.d wg
Ta b:
La yo ut1
Sacramento County Airport System (SCAS) This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento
Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
M-E Engineers, Inc.
10055 west 43rd avenue wheat ridge, co 80033 www.me-engineers.com
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
BL - 306
GATEWAY BAR
1/3/12 AS-BUILT
DEMOLITION PLAN 1
A-2.0
PLAN
DEMOLITION
04/01/11 FINAL SUBMITTAL
05/03/11 PERMIT SET
E
E.1
REVISIONS
DATENO. DESCRIPTION
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
SCALE:
Up da ted
1/7 /20
P rin ted
1/7 /20
9:
:47
P M
B y:
a dm in Fil e:
G:
\10
S
MF
F oo d & B ev er ag e\3
_d wg s\G
AT
EW
AY
B L-
6\s he ets
\S
MF
-B L3
-S
SP
-G
AT
EW
AY
-A
.2.
1.d wg
Ta b:
La yo ut1
Sacramento County Airport System (SCAS) This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento
Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
M-E Engineers, Inc.
10055 west 43rd avenue wheat ridge, co 80033 www.me-engineers.com
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
BL - 306
GATEWAY BAR
1/3/12 AS-BUILT
FLOOR PLAN 1
A-2.1
FLOOR PLAN
CONSTRUCTION
04/01/11 FINAL SUBMITTAL
1 06/01/11 PLAN CHECK RESPONSE
E
E.1
REVISIONS
DATENO. DESCRIPTION
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
SCALE:
Up da ted
1/7 /20
P rin ted
1/7 /20
9:
:08
P M
B y:
a dm in Fil e:
G:
\10
S
MF
F oo d & B ev er ag e\3
_d wg s\G
AT
EW
AY
B L-
6\s he ets
\S
MF
-B L3
-S
SP
-G
AT
EW
AY
-A
.2.
2.d wg
Ta b:
La yo ut1
Sacramento County Airport System (SCAS) This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento
Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
M-E Engineers, Inc.
10055 west 43rd avenue wheat ridge, co 80033 www.me-engineers.com
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
BL - 306
GATEWAY BAR
1/3/12 AS-BUILT
REFLECTED CEILING PLAN 1
A-2.2
CEILING PLAN
REFLECTED
04/01/11 FINAL SUBMITTAL
1 6/24/11 TRANSFORMER RELOCATION
E
E.1
REVISIONS
DATENO. DESCRIPTION
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
SCALE:
Up da ted
1/7 /20
P rin ted
1/7 /20
9:
:18
P M
B y:
a dm in Fil e:
G:
\10
S
MF
F oo d & B ev er ag e\3
_d wg s\G
AT
EW
AY
B L-
6\s he ets
\S
MF
-B L3
-S
SP
-G
AT
EW
AY
-A
.2.
3.d wg
Ta b:
La yo ut1
Sacramento County Airport System (SCAS) This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento
Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
M-E Engineers, Inc.
10055 west 43rd avenue wheat ridge, co 80033 www.me-engineers.com
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
BL - 306
GATEWAY BAR
1/3/12 AS-BUILT
EQUIPMENT PLAN 1
A-2.3
PLAN
FF&E
E
E.1
A-2.4
PLAN
FLOOR FINISH
04/01/11 FINAL SUBMITTAL
05/03/11 PERMIT SET
REVISIONS
DATENO. DESCRIPTION
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
SCALE:
Up da ted
1/7 /20
P rin ted
1/7 /20
9:
:30
P M
B y:
a dm in Fil e:
G:
\10
S
MF
F oo d & B ev er ag e\3
_d wg s\G
AT
EW
AY
B L-
6\s he ets
\S
MF
-B L3
-S
SP
-G
AT
EW
AY
-A
.2.
4.d wg
Ta b:
La yo ut1
Sacramento County Airport System (SCAS) This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento
Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
M-E Engineers, Inc.
10055 west 43rd avenue wheat ridge, co 80033 www.me-engineers.com
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
BL - 306
GATEWAY BAR
1/3/12 AS-BUILT
EQUIPMENT PLAN 1
7 7.8
DD
77.8
REVISIONS
DATENO. DESCRIPTION
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
SCALE:
Up da ted
1/7 /20
P rin ted
1/7 /20
9:
:42
P M
B y:
a dm in Fil e:
G:
\10
S
MF
F oo d & B ev er ag e\3
_d wg s\G
AT
EW
AY
B L-
6\s he ets
\S
MF
-B L3
-S
SP
-G
AT
EW
AY
-A
.3.
1.d wg
Ta b:
La yo ut1
Sacramento County Airport System (SCAS) This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento
Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
M-E Engineers, Inc.
10055 west 43rd avenue wheat ridge, co 80033 www.me-engineers.com
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
BL - 306
GATEWAY BAR
1/3/12 AS-BUILT
INTERIOR ELEVATIONS 2
INTERIOR ELEVATIONS 3
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS 4
3A3B
1A
3C
A-3.1
ELEVATIONS
INTERIOR
04/01/11 FINAL SUBMITTAL
1B1C
D E
77.88.4
A-3.2
ELEVATIONS
STOREFRONT
04/01/11 FINAL SUBMITTAL
05/03/11 PERMIT SET
REVISIONS
DATENO. DESCRIPTION
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
SCALE:
Up da ted
1/7 /20
P rin ted
1/7 /20
9:
:51
P M
B y:
a dm in Fil e:
G:
\10
S
MF
F oo d & B ev er ag e\3
_d wg s\G
AT
EW
AY
B L-
6\s he ets
\S
MF
-B L3
-S
SP
-G
AT
EW
AY
-A
.3.
2.d wg
Ta b:
La yo ut1
Sacramento County Airport System (SCAS) This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento
Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
M-E Engineers, Inc.
10055 west 43rd avenue wheat ridge, co 80033 www.me-engineers.com
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
BL - 306
GATEWAY BAR
1/3/12 AS-BUILT
EXTERIOR ELEVATION 2
EXTERIOR ELEVATION
DD
REVISIONS
DATENO. DESCRIPTION
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
SCALE:
Up da ted
1/7 /20
P rin ted
1/7 /20
9:
:59
P M
B y:
a dm in Fil e:
G:
\10
S
MF
F oo d & B ev er ag e\3
_d wg s\G
AT
EW
AY
B L-
6\s he ets
\S
MF
-B L3
-S
SP
-G
AT
EW
AY
-A
.4.
1.d wg
Ta b:
La yo ut1
Sacramento County Airport System (SCAS) This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento
Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
M-E Engineers, Inc.
10055 west 43rd avenue wheat ridge, co 80033 www.me-engineers.com
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
BL - 306
GATEWAY BAR
1/3/12 AS-BUILT
2SECTION
1SECTION
4NOT USED 3SECTION
5NOT USED
A-4.1
SECTIONS
INTERIOR
04/01/11 FINAL SUBMITTAL
6SECTION
DATENO. DESCRIPTION
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
SCALE:
Up da ted
1/7 /20
P rin ted
1/7 /20
9:
:24
P M
B y:
a dm in Fil e:
G:
\10
S
MF
F oo d & B ev er ag e\3
_d wg s\G
AT
EW
AY
B L-
6\s he ets
\S
MF
-B L3
-S
SP
-G
AT
EW
AY
-A
.4.
2.d wg
Ta b:
La yo ut1
Sacramento County Airport System (SCAS) This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento
Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
M-E Engineers, Inc.
10055 west 43rd avenue wheat ridge, co 80033 www.me-engineers.com
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
BL - 306
GATEWAY BAR
1/3/12 AS-BUILT
ENLARGED REFLECTED CEILING PLAN 2
ENLARGED REFLECTED CEILING PLAN3CEILING PANEL DETAIL
5SECTION - DROPPED CEILING PANEL
4SECTION - DROPPED CEILING PANEL
A-4.2
AND DETAILS
CEILING SECTIONS
1/4" CAULK WITH SEALANT
4" METAL STUDS, 20 GA. @ 16" O.C.
POWDER�DRIVEN FASTENERS @ 24" O.C.
5/8" TYPE "X" GYPSUM BOARD
DEFLECTION TRACK
POWDER�DRIVEN FASTENERS @ 24" O.C.
FINISH PER INTERIOR ELEVATIONS
BASE TO MATCH EXISTING AIRPORT FINISH BASE
SEE RCP FOR
CEILING HEIGHTS, WHERE
CEILING OCCURS
1/4" CAULK AIRTIGHT WITH
ACOUTSICAL SEALANT
BATT INSULATION
WOOD PANEL, WD�2
5 7/8"
HOLD GYPSUM BOARD BACK 1/4"; CAULK
WITH SEALANT
4" METAL STUDS, 20 GA. @ 16" O.C.
POWDER�DRIVEN FASTENERS @ 24" O.C.
5/8" GYPSUM BOARD, SEE LEGEND FOR TYPES
DEFLECTION TRACK
POWDER�DRIVEN FASTENERS @ 24" O.C.
SEE RCP FOR
CEILING HEIGHTS, WHERE
CEILING OCCURS
5 1/4"
FINISH PER INTERIOR ELEVATIONS
BASE PER INTERIOR ELEVATIONS
SEE RCP FOR
CEILING HEIGHTS, WHERE
CEILING OCCURS
HOLD GYPSUM BOARD BACK 1/4";
CAULK AIRTIGHT WITH ACOUTSICAL
SEALANT
BATT INSULATION
TYPE 1X: USE TYPE "X" GYPSUM
BOARD ON THE BOH SIDE. AT TYPE
"X" LOCATIONS, THE BOTTOM 16"
SHALL BE CEMENT BOARD
(WONDERBOARD OR DUROCK)
TYPE 1X': USE TYPE "X" GYPSUM
BOARD ON BOTH SIDES
TYPE 1C: USE CEMENT BOARD
(WONDERBOARD OR DUROCK)
1/4" CAULK WITH SEALANT
4" METAL STUDS, 20 GA. @ 16" O.C.
POWDER�DRIVEN FASTENERS @ 24" O.C.
3/8" TILE, TL�5, SEE INTERIOR ELEVATION
DEFLECTION TRACK
POWDER�DRIVEN FASTENERS @ 24" O.C.
SEE RCP FOR
CEILING HEIGHTS, WHERE
CEILING OCCURS
5 1/8"
1/2" CEMENT BOARD
HOLD GYPSUM BOARD BACK 1/4"; CAULK
WITH SEALANT
4" METAL STUDS, 20 GA. @ 16" O.C.
POWDER�DRIVEN FASTENERS @ 24" O.C.
5/8" GYPSUM BOARD
DEFLECTION TRACK
POWDER�DRIVEN FASTENERS @ 24" O.C.
SEE RCP FOR
CEILING HEIGHTS, WHERE
CEILING OCCURS
4 5/8"
FINISH PER INTERIOR ELEVATIONS
BASE PER INTERIOR ELEVATIONS
TYPE 3X: USE TYPE
"X" GYPSUM BOARD
EXISTING WALL
WHERE OCCURS
1/4" CAULK WITH SEALANT
6" METAL STUDS, 20 GA. @24" O.C.
POWDER�DRIVEN FASTENERS @ 24" O.C.
1/2" PLYWOOD
DEFLECTION TRACK
POWDER�DRIVEN FASTENERS @ 24" O.C.
SEE RCP FOR
CEILING HEIGHTS, WHERE
CEILING OCCURS
6 1/2"
WOOD PANEL, WD�2
HOLD GYPSUM BOARD BACK 1/4"; CAULK
WITH SEALANT
4" METAL STUDS, 20 GA. @ 16" O.C.
POWDER�DRIVEN FASTENERS @ 24" O.C.
5/8" WATER�RESISTANT GYPSUM BOARD
(GREENBOARD) ON THE BOH SIDE. AT
GREENBOARD LOCATIONS, THE BOTTOM 16"
SHALL BE CEMENT BOARD (WONDERBOARD
OR DUROCK)
DEFLECTION TRACK
POWDER�DRIVEN FASTENERS @ 24" O.C.
SEE RCP FOR
CEILING HEIGHTS, WHERE
CEILING OCCURS
FINISH PER INTERIOR ELEVATIONS
BASE PER INTERIOR ELEVATIONS
SEE RCP FOR
CEILING HEIGHTS, WHERE
CEILING OCCURS
HOLD GYPSUM BOARD BACK 1/4";
CAULK AIRTIGHT WITH ACOUTSICAL
SEALANT
BATT INSULATION
3/8" TILE, TL�5, SEE INTERIOR ELEVATION
1/2" CEMENT BOARD
PARTITION PER PARTITION TYPES
POWDER�DRIVEN FASTENERS @ 24" O.C. TO LOW
FLUTE OF DECK
DEFLECTION TRACK
BOTTOM OF METAL DECK
16 GA. STEEL PLATE
Sacramento County Airport System (SCAS)
This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
REVISIONS
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
10055 west 43rd avenue wheat ridge, co 80033 t.303.421.6655/f.303.421.0331 www.me�engineers.com
M�E Engineers, Inc.
SMARTDESIGN GROUP (US) LTD.
Interior Design � Project Management
10125 Washington Blvd.
Culver City, CA 90232 toll free: 1.877.633.7434 www.smartdesigngroup.com
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
SCALE:
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
BL � 306
GATEWAY
1/3/12 AS�BUILT
INTERIOR PARTITION
DETAILS
A�5.1g
Author
Checker
3" = 1'�0" 7GATEWAY TYPE 7 � 4" STUD WALL W/ INSUL. 3" = 1'�0" 1GATEWAY TYPE 1 � 4" STUD WALL W/ INSUL.
3" = 1'�0" 2
GATEWAY TYPE 2 � 4" STUD WALL ONE�SIDED WITH
TILE
3" = 1'�0" 3
GATEWAY TYPE 3 � 4" STUD WALL ONE�SIDED NO
INSUL.
3" = 1'�0" 4
GATEWAY TYPE 4 � 6" STUD WALL ONE�SIDED NO
INSUL.
3" = 1'�0" 6GATEWAY TYPE 6 � 4" STUD WALL W/ TILE
3" = 1'�0" 8
GATEWAY TYP. WALL CONNECTION PARALLEL TO
METAL DECK
NOT USED
NO. DATE DESCRIPTION
4/1/11 FINAL SUBMITTAL
5/3/11 PERMIT SET
9'�0"
A.F.F
LEASE LINE
FINISHED FLOOR
SEALANT, TYP.
STOREFRONT
SYSTEM
A L
IG
N
3/4" WOOD, WD�2
OVER 1/2" PLYWOOD
SUBSTRATE
BLOCKING
3/4" FURRING
CHANNEL
EXISTING METAL STUD
4' 20 GA. METAL STUD
@ 16" O.C.
9'�0"
A.F.F
LEASE LINE
SEALANT, TYP.STOREFRONT
SYSTEM
3/4" WOOD, WD�2
OVER 1/2" PLYWOOD
SUBSTRATE
BLOCKING 3/4" FURRING
CHANNEL
EXISTING METAL STUD
4" 20 GA. METAL STUD
@ 16" O.C.
9'�0"
A.F.F
LEASE LINE
GRAPHIC PANEL PER
SIGNAGE PACKAGE
9'�2"
A.F.F
SLIDING PANEL
1' � 6"
CONT. STEEL ANGLE 6"X3�
1/2"X3/8" WITH VERTICAL SLOT
FOR BOLTED CONNECTION
6"X4"X3/8" ANGLE, 3"
SECTIONS @ 2'�0" O.C., WELD
TO BASE BUILDING STEEL;
PROVIDE THREADED ROD
FOR BOLTED CONNECTION
11'�0"
A.F.F
FINISHED FLOOR
SEALANT, TYP.
STOREFRONT
SYSTEM
9"
10'�0" A.F.F.
SEE R.C.P.
3/4" WOOD, WD�2
OVER 1/2" PLYWOOD
SUBSTRATE
3�5/8" 20 GA. METAL
STUD @ 16" O.C.
EXISTING METAL STUD
T Y
P
3/4" FURRING CHANNEL
2'�2"
A.F.F
LEASE LINE
STOREFRONT
SYSTEM
3/4" WOOD, WD�2
OVER 1/2" PLYWOOD
SUBSTRATE
BLOCKING
4' 20 GA. METAL STUD
@ 16" O.C.
3/4"
(E) NEUTRAL PIER BASE BUILDING
LEASE LINE
SEE PLAN FOR
PARTITION TYPE
16 GA. HOLLOW METAL DOOR FRAME ASSEMBLY W/ 18 GA.
STEEL 'Z' CLIPS:2 PER HEAD MIN. AND 3 PER JAMB MIN;
WELDED TO FRAME, PAINTED TO MATCH WOOD, WD�2
DOOR, SEE FLOOR PLAN
& DOOR SCHEDULE FOR
ADDITIONAL INFO.
3/4" WOOD, WD�1 OVER
1/2" PLYWOOD SUBSTRATE
3/4" BLACK REVEAL
BLOCKING AS REQUIRED
/4
LEASE LINE
SEE PLAN FOR
PARTITION TYPE
3/4" WOOD, WD�2 OVER 1/2"
PLYWOOD SUBSTRATE
STOREFRONT
SYSTEM
BLOCKING
(E) NEUTRAL PIER BASE BUILDING
LEASE LINE
SEE PLAN FOR
PARTITION TYPE
3/4" WOOD, WD�2 OVER 1/2"
PLYWOOD SUBSTRATE
3/4" BLACK REVEAL
BLOCKING
/4
STOREFRONT SYSTEM
BLOCKING
SEALANT, TYP.
LEASE LINE
SEALANT, TYP.
STOREFRONT
SYSTEM
ALIGN
3/4" WOOD, WD�2
OVER 1/2" PLYWOOD
SUBSTRATE
BLOCKING
(E) NEUTRAL PIER
BASE BUILDING
3/4" BLACK REVEAL
SEEE PLAN FOR
PARTITION TYPE
BLOCKING
Sacramento County Airport System (SCAS)
This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
REVISIONS
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
10055 west 43rd avenue wheat ridge, co 80033 t.303.421.6655/f.303.421.0331 www.me�engineers.com
M�E Engineers, Inc.
SMARTDESIGN GROUP (US) LTD.
Interior Design � Project Management
10125 Washington Blvd.
Culver City, CA 90232 toll free: 1.877.633.7434 www.smartdesigngroup.com
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
SCALE:
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
BL � 306
GATEWAY
1/3/12 AS�BUILT
WALL / STOREFRONT
DETAILS
A�5.2g
3" = 1'�0" 2GATEWAY STOREFRONT SECTION � FIXED PANEL
3" = 1'�0" 3
GATEWAY STOREFRONT HEAD DETAIL @
BANQUETTE
3" = 1'�0" 5GATEWAY STOREFRONT/SLIDING DOOR SECTION
3" = 1'�0" 1
GATEWAY STOREFRONT SILL DETAIL @
BANQUETTE
3" = 1'�0" 4GATEWAY DOOR JAMB / WALL DETAIL 3" = 1'�0" 6GATEWAY STOREFRONT JAMB DETAIL
3" = 1'�0" 7
GATEWAY STOREFRONT JAMB DETAIL @
BANQUETTE
3" = 1'�0" 8GATEWAY STOREFRONT JAMB DETAIL @ ENTRY
NO. DATE DESCRIPTION
(IF NOT 2" SCALE ACCORDINGLY)
AT FULL SIZE
LINE IS 2 INCHES
6900 AIRPORT BLVD.
SACRAMENTO, CA 95837
DRAWING NO.
SHEET TITLE
DESIGNED BY:
FILE NAME:
DRAWN BY:
DATE:
CHECKED BY:
SCALE:
Up da ted
1/7 /20
P rin ted
1/7 /20
9:
:34
P M
B y:
a dm in Fil e:
G:
\10
S
MF
F oo d & B ev er ag e\3
_d wg s\G
AT
EW
AY
B L-
6\s he ets
\S
MF
-B L3
-S
SP
-G
AT
EW
AY
-A
.5.
4.d wg
Ta b:
La yo ut1
Sacramento County Airport System (SCAS) This plan has been reviewed for compliance with the SCAS requirements and is for the purpose of allowing these plans to be submitted to the County of Sacramento
Building Inspection Division (and other agencies as required) for construction permits. This approval by SCAS does not relieve the applicant from complying with additional conditions.
Approved ____________________________________ Date ________________
10125 WASHINGTON BOULEVARD
CULVER CITY, CALIFORNIA 90232
T. 323.935.3158
M-E Engineers, Inc.
10055 west 43rd avenue wheat ridge, co 80033 www.me-engineers.com
AS SHOWN
TERMINAL B
LANDSIDE
FOOD & BEVERAGE
BL - 306
GATEWAY BAR
1/3/12 AS-BUILT
1FIRE DOOR JAMB /SEISMIC JOINT
COVER DETAIL
2SEISMIC JOINT COVER AT FLOOR
DOOR SCHEDULE
3FIRE DOOR HEAD / SEISMIC JOINT COVER DETAIL
A-5.4
AND DETAILS
DOOR SCHEDULE
45° TYP.
HANGER WIRE
VERTICAL STRUT
SPLAY WIRE BRACING
ACOUSTIC TILE CEILING GRID SYSTEM
ACOUSTIC TILE CEILING
MAIN TEE PER SPECS.
INTERSECTION
CROSS TEE PER SPECS.
RIGID VERTICAL STRUT AT 12'�0" O.C. MAX. EACH WAY
WITH FIRST STRUT WITHIN 6'�0" OF VERTICAL WALL
MAX. IN EACH CASE, FASTENED TO MAIN RUNNER &
STRUCTURE ABOVE 12 GA. SPLAY BRACING WIRES
PARALLEL TO MAIN TEE AT EA.
STRUT, MAX. 12'�0" O.C. EA. WAY,
MIN. 4 TIGHT TURNS IN 1�1/2" AT
BOTH ENDS OF WIRE (TYP.)
12 GA. SPLAY BRACING WIRES
PARALLEL TO CROSS TEE AT EA.
STRUT, MAX. 12'�0" O.C. EA. WAY,
MIN. 4 TIGHT TURNS IN 1�1/2" AT
BOTH ENDS OF WIRE (TYP.)
8 GA. VERT. HANGER WIRE @ 4'�0"
O.C. EA. WAY WITH MIN. 3 TIGHT
TURNS IN 1�1/2" AT BOTH ENDS OF
WIRE (TYP.)
45°
45°
45°
2"
2"
45°
/2
CRIMP TIGHT BASE W/ 4
TWISTS MIN. TO FOLLOW
TYP. (4) PLACES
M A
X
O .C
T
Y P
/4
3/4"
8" MAX.
6'�0"
MAX.
12'�0"
O.C., TYP.
M A
X
F
IN
C
L G
H E
IG
H
T
8" MAX.
3/4"
STRUT
90°90°
NOTES
1. BRACING WIRES SECURED TO MAIN RUNNERS WITHIN 2" OF THE CROSS RUNNER INTERSECTION
AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE
PLANE OF THE CEILING.
2. IN LIEU OF 2" CLOSURE ANGLES, PROVIDE SEISMIC CLIPS AT WALL ANGLES (ATTACHED TO WALL AT
TWO SIDES, UNATTACHED AT OPPOSITE SIDES) PER ICC�ES ESR�1308 (BERC�2 CLIP)
3. LATERAL…