Biloxi VA Reno B1_103287_SET_H.pdf

PDF 6 MB Posted

Attached to
Biloxi Building 1 Renovation - Biloxi, MS -- Y1DA
Solicitation number
QSE--36C10F24R50025
Issued by

About this file

This document package includes a pre-solicitation notice and draft solicitation for the Biloxi Building 1 Renovation project in Biloxi, Mississippi. The Department of Veterans Affairs seeks to renovate areas within Building 1, including selective demolition, exterior building envelope alterations, and interior renovations on floors 3, 4, 5, and within crawl spaces and the attic. Upgrades are required for HVAC, plumbing, electrical, telecommunication, chilled water, and fire protection systems. Limited structural, mechanical, and electrical work will occur on the occupied second floor related to the underside of the third floor. The awardee must also monitor the existing building foundation throughout the project duration using a qualified consultant. Responses to the pre-solicitation notice are due within 30 days, with award of the firm-fixed price design-bid-build contract anticipated by the fourth quarter of fiscal year 2023.

View the file

Other files

File Type Posted
C28_Specifications Vol I (Biloxi Bldg 1 Reno) - 10.27.23.pdf PDF
Building 1 Inventory (b).pdf PDF
05 Architectural 4.pdf PDF
05 Architectural 1b.pdf PDF
01 General.pdf PDF
05 Architectural 2.pdf PDF
Building 1 Inventory (a).pdf PDF
10 Electrical_1.pdf PDF
13 Reference Drawings.pdf PDF
08 Plumbing_2a.pdf PDF
A-dec Floor Plan - VA Biloxi - Rev 2-24-23-Preliminary.pdf PDF
Compass Headwall 1.11.23.pdf PDF
VA Biloxi Patient Room Footwall Typical Elevation.pdf PDF
09 Mechanical_2.pdf PDF
07 Fire Protection.pdf PDF
A-dec Floor Plan - VA Biloxi - Rev 2-24-23-ELEVATIONS.pdf PDF
000000 Cover Page Appendix.pdf PDF
09 Mechanical_1.pdf PDF
04 Structural 1.pdf PDF
04 Structural 2.pdf PDF
LOCQ7780-03-SWS-Biloxi VA Dental Lab Drawing 1-5.pdf PDF
10 Electrical_2.pdf PDF
05 Architectural 3.pdf PDF
08 Plumbing_1.pdf PDF
Building 1 Inventory (d).pdf PDF
05 Architectural 1a.pdf PDF
08 Plumbing_2b.pdf PDF
Adec Submittal - VA Biloxi.pdf PDF
11 Telecommunication.pdf PDF
VA Biloxi 3rd Floor Footwall 2-13-23 FINAL-30x42.pdf PDF
Building 1 Inventory (c).pdf PDF
S02_DRAFT SOLICITATION (36C10F24R50025) - 02.07.24.pdf PDF
VA Biloxi 4th Floor Footwall 2-13-23 FINAL-30x42.pdf PDF
C28_Specifications Vol II (Biloxi Bldg 1 Reno) - 10.27.23.pdf PDF
06 Interior.pdf PDF
Pre-Solicitation Notice - Sources Sought Notice - Biloxi Bldg 1 Reno.docx DOCX document
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

SIGNOFF / APPROVAL NOTES

1. The facility structure capacity must be able to support the load specified on the installation drawing.

2. Electrical power source provided by the facility, position to be verified in the field.

3. Guldmann Inc. reserves the right to slightly modify the track layout if necessary without Facility approval.

This includes lowering the system to avoid ceiling objects.

4. Guldmann Inc. will not be held responsible for any damages, inconvenience, resulting from hitting any non visible conduits during our installation process of which we have not been advised.

5. Modifications of door headers by the facility.

6. Signed drawings are required prior to ordering and installation of ceiling lifts.

This signature of each drawing confirms agreement of all the conditions listed above.

7. Systems are tested at 1.5 times capacity.

550 lbs. tested at 825 lbs.; 770 lbs. tested at 1155 lbs.; 825 lbs. tested at 1238 lbs.; 1100 lbs. tested at 1650 lbs.

MY SIGNATURE BELOW VERIFIES THAT I HAVE:

Reviewed all _____ pages, with a total quantity of _____ room(s), _____ system(s) for the approbation of layout for each room and the approbation of structure for each room.

CUSTOMER

APPROVAL: _____________________________________ DATE: _______________

DATE: DRAWN BY:

Biloxi VA Biloxi VA Reno B1 400 Veterans Ave.

Biloxi, MS 39531

PROJECT ID:103287

Biloxi VA Reno B1

FACILITY SIGNOFF

GUL101

KIT02/05/2016

20 26 26

HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

ORIGINAL PROJECT ID: 100098

Revision Schedule

Date Issued by Letter Description

02/22/2016 KIT A ID Added

03/22/2016 TRC B Add Room

04/20/2016 TRC C Add Room

08/12/2016 KIT D Adjusted Layout / Height

02/24/2017 ZLS E Adjusted Layout

07/18/2017 KIT F Adjusted Attachment

06/09/2020 STE G 26 RMs Total / Set Updated / Room Sketches

11/15/2022 CML H New Revit Background / Redrawn To Current Standards / Pages Renumbered / Project ID Number Changed

EACH FIXED RAIL TO

HAVE x1 PARALLEL & x2 PERPENDICULAR

STABILIZERS

ALL JOINTS MUST HAVE x1 PARALLEL & x1

PERPENDICULAR STABILIZER

SEE SPAN CHART

S E

E S

P A

N C

H A

R T

SEE SPAN CHART

± 22°

STABILIZERS CAN BE ROTATED 180°

Fixed rail systems Fixed rail systems must be connected by Guldmann Service Team or by a qualified installer.

A Guldmann class I transformer must be used.

Installation to follow existing rules for authorized electricians and according to IEC/UL 60601-1.

Terminals on transformers Class I Double-insulated UL approved cable must be used (Cable specification: UL category: AVLV2, min.300V, min.

80° C, min. 18AWG (1 mm2 )) Transformer DK-13991 In:

Terminal 1 = N Terminal 2 = 100-115V AC Terminal 3 = 230V AC Terminal 4 = Protective ground Out:

Terminal 5 = 33V AC Terminal 6 = 33V AC

POWER TO BE WITHIN 15 FT OF END OF FIXED RAIL

Guldmann permanent mounted ceiling aluminium rail

Hoist with trolleys movable in rail

Protective Plast Enclosure

UL approved 400V cable, green, min. 14 AWG

Protective Ground

M1

UL approved 400V double isolated cable, min. 18 AWG

ON/OFF

UL approved 400V double isolated cable, min. 18 AWG

T ra n s fo rm e r

D K

-1

Main power Permanent installation Specification of breaker:

≥ 2.5 Amp capacity Line must always be broken

L1

AC/DC charger

Main Motor Control

Emergency Stop

Safety Circuit Emergency down

Motor Function Selector Switch0 1

V A

C

U S

V

A C

P ro te c tiv e G ro u nd

V A

C

V A

C1 A

T

.5

A T

Green Light ON (or ON / OFF - sign)

Licensed Electrician to perform hardwire to transformer

MAX

PROJECTION

MAX DISTANCE BETWEEN VERTICAL SUPPORTS

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

A

B

C

X

X

X

RAIL

RAIL

RAIL

RAIL

RAIL

RAIL

INCH

METER

,23

,7

1,2

39 49 59 68 78 118 137 147 157 177 187 206 215 236 246 264

1,0 1,25 1,5 1,75 2,0 3,0 3,5 3,75 4,0 4,5 4,75 5,25 5,5 6,0 6,25 6,75

MAX. 175 KG (385 LBS.)

MAX. 205 KG (450 LBS.)

MAX. 255 KG (560 LBS.)

MAX. 300 KG (660 LBS.)

MAX. 350 KG (770 LBS.)

MAX. 375 KG (825 LBS.)

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

A-RAIL

WEIGHT: 2.6 KG/M

(1.75 LBS/FT)

B-RAIL

WEIGHT: 5.0 KG/M

(3.36 LBS/FT)

C-RAIL

WEIGHT: 6.0 KG/M

(4.03 LBS/FT)

(2 1/2")

62 mm.

(2

/4

,5 m m

(2 1/2")

62 mm.

(5 m m

(2 1/2")

62 mm.

(6

/3 m m

A

B

C

RAIL MAX. 400 KG (880 LBS.)

X

X

X

A

B

C

RAIL MAX. 500 KG (1100 LBS.)

X

X

X

7,25

8,0

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

CENTERED IN DOORWAY

76.2 mm (3")

.2 m m

DOOR JAM

MODIFICATIONS TO DOOR

FRAME/HEADER DONE BY FACILITY

AND COORDINATED WITH GULDMANN

PATIENT LIFT

m m

/2

A

B

C

D

E

F

G

H

I

J

K

Ceiling bracket standard

A / B / C

Basic High M

Basic High M

Dimensions

205 mm

580 mm

345 mm

24 mm

58.5 / 125 / 170 mm

156 mm

184 mm

425 mm

2500 mm

970 mm

340 mm

8"

22.8"

13.5"

1.5"

2.2 / 4.9 / 6.6"

6.29"

7.2"

16.75"

98"

38"

13.3"

H

A

E D

F

C

G I

B

K J

Electrical parts On/off : Automatically on activation Motor consumption : 24V DC5W Periodic load : 10/90 Power supply : 33V AC, 2.5A Supply voltage transformer : 115/230 V AC

Classification, tightness Hand control : IP 54

Weight and materials GH Switch track 90˚ : 23 lbs (10,4 kg) Switch track railpart : Anodized aluminum Plateparts : Stainless steel m m

/8

551 mm (21 3/4")

550 mm (21 5/8")

50 mm (2") m m

/2

MAX. WEIGHT LIMIT 560 LBS

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

Biloxi VA Reno B1

GEN. INFO

GUL102

KIT02/05/2016

PROJECT ID:103287

NTS

BRACING + SUPPORT

NTS

GH3 TRANSFORMER

HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

NTS

RAIL SPAN CHART

Revision Schedule

Date Issued by Number

02/22/2016 KIT A

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

WAFFLE, SPAN = 19"

NTS

DOOR HEADER HOIST PASSTHROUGH

NTS

GH3 PATIENT SLING DIMS

NTS

GH SWITCHTRACK

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

SPRING PLATE

AVAILABLE FOR A & B RAIL

FLUSH CEILING PROFILE LIP IS 7/16" X 3/8"

CUT 12 - 15 MM OF THE 2 LONGITUDE

SCREW FOR

PROFILE END

175 mm (6 3/4") 3 mm (1/8")

99 mm (4")

MINIMUM

100 mm (4")

WALL

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

GEN. INFO

GUL102.1

KIT02/05/2016

PROJECT ID:103287

Revision Schedule

Date Issued by Number

02/22/2016 KIT A

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

NTS

FLUSH CEILING PROFILE

NTS

COMBI-LOCK (375 KG / 825 LBS MAX)

HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

40° T O 90°

0°

90°

1A B

8,9

DRAWINGS APPROVED FOR THE GULDMANN

GH-3 LIFTER SYSTEM STANDARD INSTALLATION

OF SUPPORT AND CONNECTION TO WAFFLE

DECK.

SYSTEMS INSTALLED FOR 1100 POUNDS WILL BE

TESTED AT 1650 POUNDS.

SYSTEMS INSTALLED FOR 770 POUNDS WILL BE

TESTED AT 1155 POUNDS.

SYSTEMS INSTALLED FOR 550 POUNDS WILL BE

TESTED AT 825 POUNDS.

V A

R

IE

S

M A

X

9,11

HVAC / MECH

BASEPLATE x4

STABILIZERS x3

STABILIZERS

± 22°

BRIDGE / RAIL TOP

BRIDGE SECTION

GULDMANN RAIL

SPAN

OPTIONAL B

DETAIL B

DETAIL A

OPTIONAL A

8,9

WAFFLE DECK / CONCRETE BEAM

DESCRIPTIONITEM NUMBERTAG

1-5/8" X 10' B2B STRUT SLOTTED20070821

3/8" B7 THREADED RODHTHR037 12B72

STABILIZER BRACKET KIT - GULDMANN5504393

1" Ø-6013-T6 AL TUBE - GULDMANN550481-US4

CEILING BRACKET KIT - GULDMANN5504355

2 HOLE 90 DEG. BRACKETP10266

MQM-F WINGNUT 3/8"3778827

3/8" X 1-1/4" HEX BOLT4117648

3/8" X 1-1/4" X 1/8" WASHER (THICK)111012739

3/8" X 3-3/4" KB1223145610

3/8" NYLOCK NUT113702411

3/8" BEVELLED WASHER3387312

3/8" HEX NUT41175213

MQZ-L BASEPLATE 3/8"37063214

MQA-F SADDLE NUT 3/8"37788515

( USED AS NEEDED )

( OPTIONAL )

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

ATTACHMENT

GUL103

KIT02/05/2016

PROJECT ID:103287

HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

Revision Schedule

Date Issued by Number

02/22/2016 KIT A

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

GUL104

GUL104

/4

B .O

H

O

IS

T

/2

B .O

T

R A

V E

R S

E

C E

IL

IN

G

C O

M B

I- L O

C K

/2

A -R

A

IL

/8

T .O

T

R A

V E

R S

E

/8

T .O

H

O

IS

T

8" MIN.

/4

/2

/8

TRAVERSE (B-RAIL)

CEILING

/4

/2

/4

M

A X

A-RAIL

/2

/8

COMBI-LOCK

COMBI-BRACE

CEILING

TRAVERSE (B-RAIL)

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

PROJECT DETAILS

GUL104

KIT02/05/2016

PROJECT ID:103287

HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

Revision Schedule

Date Issued by Number

02/22/2016 KIT A

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

1" = 1'-0"

TYP SYSTEM HEIGHTS

1 1/2" = 1'-0"

CEILING / HOIST DETAIL

3" = 1'-0"

COMBI-LOCK DETAIL

Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

OVERALL - 3rd Floor

GUL105

CML11/15/2022

PROJECT ID:103287

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

A rail

Revision Schedule

Date Issued by Number

11/15/2022 CML H

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

1" = 20'-0"

OVERALL - 3rd Floor

HOIST COVERAGE AREA5.

Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

OVERALL - 4th Floor

GUL106

CML11/15/2022

PROJECT ID:103287

Revision Schedule

Date Issued by Number

11/15/2022 CML H

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

A rail

HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

1" = 20'-0"

OVERALL - 4th Floor

HOIST COVERAGE AREA5.

/4

/8

10' - 11 3/4" 3 7/8"

/8

2' - 3"

3'

/8

2' - 10 1/8" 1"

/8

6' - 1 3/4"

90°

SWITCHTRACK

60° RIGHT

45°

30°

60°

45°

Patient Room 1

4B114

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

TYP PATIENT ROOM 1

GUL107

KIT02/05/2016

PROJECT ID:103287

Revision Schedule

Date Issued by Number

02/22/2016 KIT A

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

A rail

HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

REFERENCE ROOMS

3B114 4B114

3/8" = 1'-0"

PATIENT ROOM 1

1' - 4 3/8"

/2

3' - 5 1/2"

3' - 2 3/8"

1' - 11"

/8

9' - 4 1/4"

8' - 4 3/8" 10"

/8

SWITCHTRACK

90° LEFT

30°

45°

45°

Patient Room 2

4B116

GUL104

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

TYP PATIENT ROOM 2

GUL108

KIT02/05/2016

PROJECT ID:103287

Revision Schedule

Date Issued by Number

02/22/2016 KIT A

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

A rail

HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

REFERENCE ROOMS

3B116 4B116

1/2" = 1'-0"

PATIENT ROOM 2

6' - 5"

/8

/2

/8

3 7/8" 10' - 9 1/8"

2' - 0 7/8"

1' - 2 3/8"

/4

2' - 0 1/2"

/2

SWICHTRACK

60° RIGHT

90°

60°

Patient Room 3

4B118

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

TYP PATIENT ROOM 3

GUL109

KIT02/05/2016

PROJECT ID:103287

Revision Schedule

Date Issued by Number

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

A rail

HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

REFERENCE ROOMS

3B118 4B118

1/2" = 1'-0"

PATIENT ROOM 3

2' - 0 1/2"

/4

SWITCHTRACK

60° LEFT

60°

90°

6' - 5"

/2

/8

/8

10' - 10 5/8" 3 7/8"

2' - 0 7/8"Patient Room 4

4B119

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

TYP PATIENT ROOM 4

GUL110

KIT02/05/2016

PROJECT ID:103287

Revision Schedule

Date Issued by Number

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

A rail

HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

REFERENCE ROOMS

3B119 4B119

1/2" = 1'-0"

PATIENT ROOM 4

2' - 0 1/2"

3' - 6 7/8"

/2

/8

/2

3 7/8" 11' - 2 1/4"

/8

30°

90°

SWITCHTRACK

60° RIGHT

30°

30°

30°

Patient Room 5

4B123

7' - 1 5/8"

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

TYP PATIENT ROOM 5

GUL111

KIT02/05/2016

PROJECT ID:103287

Revision Schedule

Date Issued by Number

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

A rail

HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

REFERENCE ROOMS

3B123 4B123

1/2" = 1'-0"

PATIENT ROOM 5

Patient Room 6

4B124

/2

/8

11' - 1 3/4" 3 7/8"

/8

7' - 1 3/8"

/8 "2' - 0 1/2"

3' - 3 1/4"

1' - 1 1/4"

/4

SWITCHTRACK

60° LEFT

90°

30°

30°

30°

30°

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

TYP PATIENT ROOM 6

GUL112

KIT02/05/2016

PROJECT ID:103287

Revision Schedule

Date Issued by Number

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

REFERENCE ROOMS

3B124 4B124 HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

A rail

1/2" = 1'-0"

PATIENT ROOM 6

SWITCHTRACK

90° LEFT

45°

45°

1" 4' - 10 3/8"

/4

2' - 0 3/8"

9' - 6 1/4"

8' - 4 3/8" 10 3/4"

/2

"Patient Room 7 (Neg. Press.)

4B111

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

TYP PATIENT ROOM 7

GUL113

KIT02/05/2016

PROJECT ID:103287

Revision Schedule

Date Issued by Number

02/22/2016 KIT A

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

REFERENCE ROOMS

3B111 4B111 HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

A rail

3/8" = 1'-0"

PATIENT RM 7 (Neg. Press.)

/8

/8

M A

X

3 7/8" 10' - 3 5/8"

1' - 1 1/2"

2' - 6 1/2"

/4

3' - 11 3/4"

1' - 6 1/2"

60°

30°

90°

30°

SWITCHTRACK

60° RIGHT

Patient Room 8

4A117

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

TYP PATIENT ROOM 8

GUL114

KIT02/05/2016

PROJECT ID:103287

Revision Schedule

Date Issued by Number

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

REFERENCE ROOMS

3A117 4A117 HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

A rail

1/2" = 1'-0"

PATIENT ROOM 8

11' - 3 1/2" 3 7/8"

/8

M A

X

/2

1' - 7 7/8"

1' - 0 3/8"

3' - 9 1/2"

/2

2' - 6 1/2"

60°

90°

30°

SWITCHTRACK

60° LEFT

30°

Patient Room 9

4A118

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

TYP PATIENT ROOM 9

GUL115

KIT02/05/2016

PROJECT ID:103287

Revision Schedule

Date Issued by Number

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

REFERENCE ROOMS

3A118 4A118 HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

A rail

1/2" = 1'-0"

PATIENT ROOM 9

Patient Room 10

4A122

/8

/8

3 7/8" 11' - 8 1/8"

/2

2' - 0 5/8"

1' - 8 7/8"

6' - 7 7/8"

SWITCKTRACK

60° RIGHT

90°

30°

30°

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

TYP PATIENT ROOM 10

GUL116

KIT02/05/2016

PROJECT ID:103287

Revision Schedule

Date Issued by Number

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

REFERENCE ROOMS

3A122 4A122 HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

A rail

1/2" = 1'-0"

PATIENT ROOM 10

Patient Room 11

4A123

/2

/8

11' - 10 7/8" 3 7/8"

/8

1' - 8 5/8"

/2

1' - 11"

1' - 2"

/4

6' - 9 3/8"

SWITCKTRACK

60° LEFT

90°

30°

30°

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

TYP PATIENT ROOM 11

GUL117

KIT02/05/2016

PROJECT ID:103287

Revision Schedule

Date Issued by Number

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

REFERENCE ROOMS

3A123 4A123 HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

A rail

1/2" = 1'-0"

PATIENT ROOM 11

Bariatric Patient Room 12

4A125

3 7/8" 12' - 9 5/8"

/2

/8

/2

2' - 9 7/8"

/2

3' - 5 3/8"

2' - 0 5/8"

3' - 0"

/4

30°

60°

SWITCHTRACK

60° RIGHT

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

TYP BARI PATIENT ROOM 12

GUL118

KIT02/05/2016

PROJECT ID:103287

Revision Schedule

Date Issued by Number

03/22/2016 TRC B

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

REFERENCE ROOMS

3A125 4A125 HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

A rail

3/8" = 1'-0"

BARI PATIENT ROOM 12

Bariatric Patient Room 13

(Neg. Press.)

4A131

1' - 4 3/4"

3' - 0 3/8" 7' - 7" 1"

/4

/8

M A

X

SWITCHTRACK

60° RIGHT

30°

3 7/8" 13' - 1 1/2"

Guldmann Inc.

14401 McCormick Drive Tampa FL, 33626 Unit A

Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558

Email: Info@Guldmann.net

NOTES

APPROVED BY:

PROJECT NAME:

SHEET DESCRIPTION:

SHEET NO:

DATE: DRAWN BY:

SEE 3/GUL102 FOR RAIL SPANS & ADDITIONAL DIMENSIONS

Biloxi VA Reno B1

TYP PATIENT ROOM 13

GUL119

KIT02/05/2016

PROJECT ID:103287

Revision Schedule

Date Issued by Number

02/22/2016 KIT A

08/12/2016 KIT D

02/24/2017 ZLS E

07/18/2017 KIT F

06/09/2020 STE G

11/15/2022 CML H

REFERENCE ROOMS

3A131 4A131 HOIST = 550 LBS1.

FLUSH RECESSED / TYPE P2.

CEILING HEIGHT = 9' - 0"3.

AFF TO DECK = 13' - 6"

ATTACHMENT TYPE =4.

WAFFLE, SPAN = 19"

w/ SWITCHTRACK

HOIST COVERAGE AREA5.

CENTER IN DOORWAY6.

CENTER TO TOILET7.

Stabilizers

Combi-lock

B rail

Hoist Transformer

Hoist

Wall switch for TTBL/SWT

KEY

Ceiling bracket, Extended

A rail

3/8" = 1'-0"

BARI PATIENT RM 13 (Neg. Press.)

Sheets
GUL101 - FACILITY SIGNOFF
GUL102 - GEN. INFO
GUL102.1 - GEN. INFO
GUL103 - ATTACHMENT
GUL104 - PROJECT DETAILS
GUL105 - OVERALL - 3rd Floor
GUL106 - OVERALL - 4th Floor
GUL107 - TYP PATIENT ROOM 1
GUL108 - TYP PATIENT ROOM 2
GUL109 - TYP PATIENT ROOM 3
GUL110 - TYP PATIENT ROOM 4
GUL111 - TYP PATIENT ROOM 5
GUL112 - TYP PATIENT ROOM 6
GUL113 - TYP PATIENT ROOM 7
GUL114 - TYP PATIENT ROOM 8
GUL115 - TYP PATIENT ROOM 9
GUL116 - TYP PATIENT ROOM 10
GUL117 - TYP PATIENT ROOM 11
GUL118 - TYP BARI PATIENT ROOM 12
GUL119 - TYP PATIENT ROOM 13

File details come from the government source that posted it. Updated .