07 Fire Protection.pdf

PDF 4 MB Posted

Attached to
Biloxi Building 1 Renovation - Biloxi, MS -- Y1DA
Solicitation number
QSE--36C10F24R50025
Issued by

About this file

This document package includes construction drawings and specifications for the Biloxi Building 1 Renovation project located in Biloxi, Mississippi. The project involves selective demolition, building envelope alterations, and interior renovations to floors 3, 4 and 5 as well as crawl spaces and attics. Work includes upgrades to HVAC, plumbing, electrical, telecommunications, chilled water systems and modifications to fire protection. Limited structural, mechanical and electrical work will occur in occupied areas on the second floor. The awardee must also monitor the existing building foundation throughout the project duration. The solicitation seeks offers for all labor, materials, equipment and supervision to complete the project requirements. The Department of Veterans Affairs Office of Construction and Facilities Management will award a firm fixed price contract.

View the file

Other files

File Type Posted
C28_Specifications Vol I (Biloxi Bldg 1 Reno) - 10.27.23.pdf PDF
Building 1 Inventory (b).pdf PDF
05 Architectural 4.pdf PDF
05 Architectural 1b.pdf PDF
01 General.pdf PDF
05 Architectural 2.pdf PDF
Building 1 Inventory (a).pdf PDF
Biloxi VA Reno B1_103287_SET_H.pdf PDF
10 Electrical_1.pdf PDF
13 Reference Drawings.pdf PDF
08 Plumbing_2a.pdf PDF
A-dec Floor Plan - VA Biloxi - Rev 2-24-23-Preliminary.pdf PDF
Compass Headwall 1.11.23.pdf PDF
VA Biloxi Patient Room Footwall Typical Elevation.pdf PDF
09 Mechanical_2.pdf PDF
A-dec Floor Plan - VA Biloxi - Rev 2-24-23-ELEVATIONS.pdf PDF
000000 Cover Page Appendix.pdf PDF
09 Mechanical_1.pdf PDF
04 Structural 1.pdf PDF
04 Structural 2.pdf PDF
LOCQ7780-03-SWS-Biloxi VA Dental Lab Drawing 1-5.pdf PDF
10 Electrical_2.pdf PDF
05 Architectural 3.pdf PDF
08 Plumbing_1.pdf PDF
Building 1 Inventory (d).pdf PDF
05 Architectural 1a.pdf PDF
08 Plumbing_2b.pdf PDF
Adec Submittal - VA Biloxi.pdf PDF
11 Telecommunication.pdf PDF
VA Biloxi 3rd Floor Footwall 2-13-23 FINAL-30x42.pdf PDF
Building 1 Inventory (c).pdf PDF
S02_DRAFT SOLICITATION (36C10F24R50025) - 02.07.24.pdf PDF
VA Biloxi 4th Floor Footwall 2-13-23 FINAL-30x42.pdf PDF
C28_Specifications Vol II (Biloxi Bldg 1 Reno) - 10.27.23.pdf PDF
06 Interior.pdf PDF
Pre-Solicitation Notice - Sources Sought Notice - Biloxi Bldg 1 Reno.docx DOCX document
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S

S S

S

S S

S

S S

S

S S SS

S S

S

S

S

S S

S S

S

S S

S S

SS S

S

S S

S

S

S

S

S

S

S S

S S

S S

S

S

S

S S

S

S S

S

SS SS

S S

S S

S

S S

S S

S S

S S

S

S

S

S

S

S

S S

S

S S

S S

S S

S

S

S SS

S

S S

S

S

S S

S S

S

S

S

S S

S

S SS S

S S

S

S

S

S

S

S SS S S SS SSS SS

S

S

S SS

S

S

S

S

S

S

S

S S

S

S S S

S

S S

S SS

S SS

FIRE PROTECTION HAZARD SCHEDULE

HAZARD SYMBOL HAZARD CLASS DESIGN CRITERIA HOSE DURATION SPRINKLER SPACING NOTES

UNO LIGHT 0.10 GPM/SF

OVER 1500SF

100 GPM 30 MIN

MAX 225 SF; MAX 15'

BETWEEN SPRINKLERS;

MAX 7.5' FROM WALL

ALL AREAS ARE LIGHT

HAZARD U.N.O.

ORDINARY HAZARD

GROUP 1

250 GPM 60 MIN

MAX 130 SF;MAX 15'

BETWEEN SPRINKLERS

MAX 7.5' FROM WALL

OH-2

OH-1

ORDINARY HAZARD

GROUP 2

250 GPM 90 MIN

MAX 130 SF;MAX 15'

BETWEEN SPRINKLERS

MAX 7.5' FROM WALL

EH-1 500 GPM 90 MIN

MAX 100 SF;MAX 12'

BETWEEN SPRINKLERS

MAX 6' FROM WALL

EXTRA HAZARD

GROUP 2

EXTRA HAZARD

GROUP 1

0.40 GPM/SF

OVER 2500SF

500 GPM 120 MIN

MAX 100 SF;MAX 12'

BETWEEN SPRINKLERS

MAX 6' FROM WALL

0.15 GPM/SF

OVER 1500SF

0.20 GPM/SF

OVER 1500SF

0.30 GPM/SF

OVER 2500SF

EH-2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22

G

F

E

D

C

B

A

7.4

F.8

F.3

B.4

B.7

D.8

D.2

B.8

B.2

10.8 12.2

EXISTING

5" STANDPIPE

TO AUTOMATIC SPRINKLER

SYSTEM.

EXISTING

1 1/2" DRAIN

EXISTING

1 1/2" DRAIN

EXISTING

4" STANDPIPE

TO AUTOMATIC SPRINKLER

SYSTEM.

PATIENT ROOM 1

3B114

PATIENT ROOM 2

3B116

PATIENT BATHROOM

3B114A

PATIENT BATHROOM

3B118A

PATIENT ROOM 3

3B118

PATIENT ROOM 4

3B119

PATIENT BATHROOM

3B119A

CLEAN EQUIPMENT STORAGE

3B121

MD DICTATION

3B122

PATIENT BATHROOM

3B123A

PATIENT ROOM 5

3B123

NURSE SERVER

3B125

PATIENT ROOM 6

3B124

PATIENT BATHROOM

3B124A

SOILED LINEN

3A110

ENGINEERING

3A111

HEAD NURSE / ASSISTANT MANAGER

3A112

CORRIDOR

C3-105

NURSE STATION

3A109A

NOURISHMENT STATION

3A115

MEDICATION ROOM

3A114

PATIENT BATHROOM

3A117A

PATIENT ROOM 8

3A117

PATIENT ROOM 9

3A118

PATIENT BATHROOM

3A118A MD DICTATION

3A120

IMD SUPPLY STORAGE

3A121

PATIENT BATHROOM

3A122A

PATIENT ROOM 10

3A122

NURSE SERVER

3A124

PATIENT ROOM 11

3A123

PATIENT BATHROOM

3A123A

BARIATRIC PATIENT ROOM 12

3A125

BARIATRIC PATIENT BATHROOM

3A125A

CONFERENCE / REPORT ROOM

3A128

HAC

3A127

NURSE SERVER

3A132

CORRIDOR

C3-103

CORRIDOR

C3-109

TELEMETRY

3A130

BARIATRIC PATIENT BATHROOM

3A131A

BARIATRIC PATIENT ROOM 13 - NEG.

PRESS.

3A131

ANTE ROOM

3A131B

CORRIDOR

C3-107

EAST STAIR

3A133

STAFF TOILET

3A136

STAFF SHOWER

3A135

CORRIDOR

3A141

SOILED UTILITY

3A142

TELECOMM

3A140

FEMALE LOCKERS

3A139

STAFF LOUNGE

3A138

MALE LOCKERS

3A137

PHARMACY CUBICLES

3A134

MALE TOILET

3A102

FEMALE TOILET

3A103

WAITING / LOUNGE

3A105

FAMILY CONSULTATION

3A106

MECHANICAL SHAFT

3A107

CORRIDOR

C3-104

PATIENT CENTERED CARE

3B103

WHEELCHAIR ALCOVE

3B102

ELECTRICAL ROOM

3B101

MEDICAL GAS STORAGE

3B104

CRASH CART

3B105

HAC

3B106

CLEAN UTILITY

3B107

CLEAN LINEN

3B108

KINESIOTHERAPY

3B109

WEST STAIR

3B110

PATIENT ROOM 7 - NEGATIVE

PRESSURE

3B111

ANTE ROOM

3B111B

UNASSIGNED

3B113

PATIENT BATHROOM

3B111A

NURSE SERVER

3B112

CORRIDOR

C3-101

FAMILY TOILET

3A104

NURSE SERVER

3A126

NURSE SERVER

3A119

NURSE SERVER

3B120

NURSE SERVER

3B117

NURSE SERVER

3B115

NURSE STATION

3A109

OH-1

OH-1

OH-1

OH-1

OH-1

OH-1

OH-1

OH-1

OH-1 OH-1

OH-1

OH-1

PROVIDE WATER CURTAIN PER

NFPA 13 FOR GLASS PROTECTION.

LEGEND

1 HOUR FIRE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE PARTITION: NON-RATED

SMOKE BARRIER - 1 HR FIRE & SMOKE

RATED

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

BID DOCUMENTS

520-317X

Dwg. of fi le s \C o rp o ra te \T e a m s \C

S L E

G

\B

IM

D o c u m e n ts \1

.0

\R e v it \I C

T

B L

D G

P lu m b in g

C D

S .r v t

/1 /2

:4

:0

P M

FX101

3RD FLOOR - FIRE PROTECTION RENOVATE BUILDING 1

BILOXI, MISSISSIPPI

10/27/2023 SCOPRZ AARMEY

132 238

1/8" = 1'-0"FX101

1 3RD FLOOR - FIRE PROTECTION

N O

R T

H

KEYED NOTES:

1. CONNECT TO EXISTING STANDPIPE & DRAIN RISER.

PROVIDE NEW CONTROL VALVE AND INSPECTOR'S TEST

VALVE AND DRAIN ASSEMBLY PER DETAIL ON SHEET PL502.

2. PROVIDE COVERAGE FOR EXISTING LINEN CHUTE AS

REQUIRED PER NFPA 13.

GENERAL NOTES:

1. REFER TO PL601 FOR FIRE PROTECTION NOTES

2. REFER TO ME100 FOR ADDITIONAL FIRE PROTECTION

NOTES.

3. REMOVE EXISTING FIRE HOSE CABINETS, PIPING,

BRACKETS, HANGERS, AND ACCESSORIES. REFER TO

ARCHITECTURAL FOR PATCHING REQUIREMENTS.

Revisions: Date:

UPUP

UPUP

S

S S

S

S S

S

S S

S

S S SS

S S

S

S

S

S S

S S

S S

SS S

S

S S

S

S S

SS S

S

S

S

S

S S

S S

S S

S

S

S S

S S

S S

S

S S

S S

S

S S

S S

S

S

S

S

S

S SS

S

S S

S S

S S

S

S

S SS

S

S S

S

S

S

S S

S

S

S

S S

S

S SS S

S S

S

S S

S S

S

S

S SS S S

S

S SSS SS S S SS S

S

S

S

S

S S S

S

S

S

S

S

S S

S

S S

S

S

S SS

S SS

FIRE PROTECTION HAZARD SCHEDULE

HAZARD SYMBOL HAZARD CLASS DESIGN CRITERIA HOSE DURATION SPRINKLER SPACING NOTES

UNO LIGHT 0.10 GPM/SF

OVER 1500SF

100 GPM 30 MIN

MAX 225 SF; MAX 15'

BETWEEN SPRINKLERS;

MAX 7.5' FROM WALL

ALL AREAS ARE LIGHT

HAZARD U.N.O.

ORDINARY HAZARD

GROUP 1

250 GPM 60 MIN

MAX 130 SF;MAX 15'

BETWEEN SPRINKLERS

MAX 7.5' FROM WALL

OH-2

OH-1

ORDINARY HAZARD

GROUP 2

250 GPM 90 MIN

MAX 130 SF;MAX 15'

BETWEEN SPRINKLERS

MAX 7.5' FROM WALL

EH-1 500 GPM 90 MIN

MAX 100 SF;MAX 12'

BETWEEN SPRINKLERS

MAX 6' FROM WALL

EXTRA HAZARD

GROUP 2

EXTRA HAZARD

GROUP 1

0.40 GPM/SF

OVER 2500SF

500 GPM 120 MIN

MAX 100 SF;MAX 12'

BETWEEN SPRINKLERS

MAX 6' FROM WALL

0.15 GPM/SF

OVER 1500SF

0.20 GPM/SF

OVER 1500SF

0.30 GPM/SF

OVER 2500SF

EH-2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22

G

F

E

D

C

B

A

7.4

F.8

F.3

B.4

B.7

D.8

D.2

B.8

B.2

10.8 12.2

EXISTING

5" STANDPIPE

TO AUTOMATIC SPRINKLER

SYSTEM.

EXISTING

1 1/2" DRAIN

EXISTING

1 1/2" DRAIN

EXISTING

4" STANDPIPE

TO AUTOMATIC SPRINKLER

SYSTEM.

PATIENT ROOM 1

4B114

PATIENT ROOM 2

4B116

PATIENT BATHROOM

4B114A

PATIENT BATHROOM

4B116A

NURSE SERVER

4B117

NURSE SERVER

4B115

PATIENT BATHROOM

4B118A

NURSE SERVER

4B120

PATIENT ROOM 3

4B118

PATIENT ROOM 4

4B119

PATIENT BATHROOM

4B119A

MD DICTATION

4B122

CLEAN EQUIPMENT STORAGE

4B121

PATIENT BATHROOM

4B123A

PATIENT ROOM 5

4B123

NURSE SERVER

4B125

PATIENT ROOM 6

4B124

PATIENT BATHROOM

4B124A

SOILED LINEN

4A110

ENGINEERING

4A111

CORRIDOR

C4-105

NURSE STATION

4A109A

NURSE STATION

4A109

STAFF EDUCATION

4A112

MEDICATION ROOM

4A114

NOURISHMENT STATION

4A115

PATIENT BATHROOM

4A117A

PATIENT ROOM 8

4A117

CORRIDOR

C4-103

TELECOMM

4A140

NURSE SERVER

4A119

PATIENT ROOM 9

4A118

PATIENT BATHROOM

4A118A

MD DICTATION

4A120

IMD SUPPLY STORAGE

4A121

NURSE SERVER

4A124

PATIENT BATHROOM

4A122A

PATIENT ROOM 10

4A122

PATIENT ROOM 11

4A123

PATIENT BATHROOM

4A123A

CORRIDOR

C4-107

HAC

4A127

BARIATRIC PATIENT BATHROOM

4A125A

CONFERENCE / REPORT ROOM

4A128

BARIATRIC PATIENT ROOM 12

4A125

NURSE SERVER

4A132

ANTE ROOM

4A131B

BED STORAGE

4A130

BARIATRIC PATIENT ROOM 13 - NEG.

PRESS.

4A131

BARIATRIC PATIENT BATHROOM

4A131A

M.O.D. ROOM

4A134

MALE LOCKERS

4A137

EAST STAIR

4A133

CORRIDOR

4A141

SOILED UTILITY

4A142

STAFF SHOWER

4A135 STAFF TOILET

4A136

FEMALE LOCKERS

4A139

CENTRAL STAIR

4A101

MALE TOILET

4A102

FEMALE TOILET

4A103

FAMILY TOILET

4A104

WAITING / LOUNGE

4A105

FAMILY CONSULTATION

4A106

MECHANICAL SHAFT

4A107

CORRIDOR

C4-104

ELECTRICAL ROOM

4B101

WHEELCHAIR ALCOVE

4B102

PATIENT CENTERED CARE

4B103

MEDICAL GAS STORAGE

4B104

CRASH CART

4B105

HAC

4B106

CLEAN UTILITY

4B107CLEAN LINEN

4B108

WEST STAIR

4B110

KINESIOTHERAPY

4B109

PATIENT ROOM 7 - NEGATIVE

PRESSURE

4B111

ANTE ROOM

4B111B

NURSE SERVER

4B112

UNASSIGNED

4B113

PATIENT BATHROOM

4B111A

CORRIDOR

C4-101

CORRIDOR

C4-109

NURSE SERVER

4A126

STAFF LOUNGE

4A138

M.O.D. BATHROOM

4A134A

OH-1

OH-1

OH-1

OH-1OH-1 OH-1

OH-1

OH-1

OH-1 OH-1

OH-1

OH-12

PROVIDE WATER CURTAIN PER

NFPA 13 FOR GLASS PROTECTION.

1 2 3 4 5 6 7 8 9

11 12

14 15 16 17 18 19 20 21 22

G

F

E

D

C

B

A

7.4

F.8

F.3

B.4

B.7

D.8

D.2

LEGEND

1 HOUR FIRE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE PARTITION: NON-RATED

SMOKE BARRIER - 1 HR FIRE & SMOKE

RATED

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

BID DOCUMENTS

520-317X

Dwg. of fi le s \C o rp o ra te \T e a m s \C

S L E

G

\B

IM

D o c u m e n ts \1

.0

\R e v it \I C

T

B L

D G

P lu m b in g

C D

S .r v t

/1 /2

:4

:0

P M

FX102

4TH FLOOR - FIRE PROTECTION RENOVATE BUILDING 1

BILOXI, MISSISSIPPI

10/27/2023 SCOPRZ AARMEY

133 238

1/8" = 1'-0"FX102

1 4TH FLOOR - FIRE PROTECTION

N O

R T

H

KEYED NOTES:

1. CONNECT TO EXISTING STANDPIPE & DRAIN RISER.

PROVIDE NEW CONTROL VALVE AND INSPECTOR'S TEST

VALVE AND DRAIN ASSEMBLY PER DETAIL ON SHEET PL502.

2. PROVIDE COVERAGE FOR EXISTING LINEN CHUTE AS

REQUIRED PER NFPA 13.

GENERAL NOTES:

1. REFER TO PL601 FOR FIRE PROTECTION NOTES

2. REFER TO ME100 FOR ADDITIONAL FIRE PROTECTION

NOTES.

3. REMOVE EXISTING FIRE HOSE CABINETS, PIPING,

BRACKETS, HANGERS, AND ACCESSORIES. REFER TO

UP

UP

UP

S SS

S S

S

SS S

S S

S

S SS S

S

S S

S

S

S

S

S S

S

S S

S

S

S S

S

SS

SS

S S

S S

S S

S

S

S

S

S S

S S

S SS

S SS

S SS

S SS

FIRE PROTECTION HAZARD SCHEDULE

HAZARD SYMBOL HAZARD CLASS DESIGN CRITERIA HOSE DURATION SPRINKLER SPACING NOTES

UNO LIGHT 0.10 GPM/SF

OVER 1500SF

100 GPM 30 MIN

MAX 225 SF; MAX 15'

BETWEEN SPRINKLERS;

MAX 7.5' FROM WALL

ALL AREAS ARE LIGHT

HAZARD U.N.O.

ORDINARY HAZARD

GROUP 1

250 GPM 60 MIN

MAX 130 SF;MAX 15'

BETWEEN SPRINKLERS

MAX 7.5' FROM WALL

OH-2

OH-1

ORDINARY HAZARD

GROUP 2

250 GPM 90 MIN

MAX 130 SF;MAX 15'

BETWEEN SPRINKLERS

MAX 7.5' FROM WALL

EH-1 500 GPM 90 MIN

MAX 100 SF;MAX 12'

BETWEEN SPRINKLERS

MAX 6' FROM WALL

EXTRA HAZARD

GROUP 2

EXTRA HAZARD

GROUP 1

0.40 GPM/SF

OVER 2500SF

500 GPM 120 MIN

MAX 100 SF;MAX 12'

BETWEEN SPRINKLERS

MAX 6' FROM WALL

0.15 GPM/SF

OVER 1500SF

0.20 GPM/SF

OVER 1500SF

0.30 GPM/SF

OVER 2500SF

EH-2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22

G

F

E

D

C

B

A

IMD SUPPLY

5B122

PANORAMIC X-RAY

5B123

STERILE INSTR. STORAGE

5B128

SOILED UTILITY

5B130

EQUIPMENT STORAGE

5B135

UNISEX TOILET

5B136

DENTIST WORKSTATIONS

5B129

OPERATORY TREATMENT GENERAL

AREA

5B131

HAC

5A110

ENGINEERING

5A111

STAFF LOUNGE

5A112

MALE TOILETS / LOCKERS

5A113

FEMALE TOILETS / LOCKERS

5A114

SCRUBS DISTRIBUTION

5A108

CRASH CART

5A115

PHYSICIANS CUBICLES

5A117

FILE ROOM

5A118

COPY ROOM

5A119

OFFICE

5A120

SUPPLY STORAGE

5A121

DIRECTORS CONFERENCE ROOM

5A122

MENS TOILET ROOM

5A124

PIPE ACCESS

5A125

WOMENS TOILET ROOM

5A126

HAC

5A127EAST STAIR

5A128

STAFF LOUNGE

5A130

OFFICE

5A131

CUBICLES

5A134

OFFICE

5A132

OFFICE

5A133

TELECOMM

5A135

CENTRAL STAIR

5A101

FAMILY TOILET

5A102

MEDICAL CONFERENCE

5A103

DENTAL CONFERENCE

5A105

MECHANICAL SHAFT

5A106

LOBBY / LOUNGE

C5-105

ELECTRICAL ROOM

5B102

WAITING

5B103

RECEPTION / SECRETARY

5B104

COPY ROOM

5B105

DENTAL SERVICE CHIEF OFFICE

5B106

MEDICATION ROOM

5B109

AO OFFICE

5B107

SHIPPING/ RECEIVING ROOM

5B110

WEST STAIR

5B111

TOILET ROOM

5B112

SOILED UTILITY

5B114

CORRIDOR

C5-104A

CORRIDOR

C5-104

CORRIDOR

C5-107A

CORRIDOR

C5-109

CORRIDOR

C5-102C

CORRIDOR

C5-106

CORRIDOR

C5-103

CORRIDOR

C5-102

OPERATORY TREATMENT GENERAL

AREA

5B115

DENTAL LAB

5B113

DENTAL TREATMENT ROOM 4

5B119

DENTAL TREATMENT ROOM 3

5B118

DENTAL TREATMENT ROOM 2

5B117

DENTAL TREATMENT ROOM 1

5B116

DENTAL TREATMENT ROOM 6

5B121

DENTAL TREATMENT ROOM 5

5B120

DENTAL TREATMENT ROOM 7

5B125

DENTAL TREATMENT ROOM 8

5B126

DENTAL TREATMENT ROOM 9 -

SPECIAL NEEDS

5B127

DENTAL TREATMENT ROOM 10-

SPECIAL NEEDS

5B132

DENTAL TREATMENT ROOM 11

5B133

DENTAL TREATMENT ROOM 12

5B134

DECONTAMINATION AREA

5B115A

7.4

F.8

F.3

B.4

B.7

D.8

D.2

B.8

B.2

10.8 12.2

CORRIDOR

C5-108

CORRIDOR

C5-107

EXISTING

5" STANDPIPE

TO AUTOMATIC SPRINKLER

SYSTEM.

EXISTING

1 1/2" DRAIN

EXISTING

1 1/2" DRAIN

EXISTING

4" STANDPIPE

TO AUTOMATIC SPRINKLER

SYSTEM.

OH-1

OH-1

OH-1

OH-1

OH-1

OH-1

OH-1

OH-1

OH-1

OH-1

OH-1

OH-1

OH-1

OH-1

OH-1

PROVIDE WATER CURTAIN PER

NFPA 13 FOR GLASS PROTECTION.

LEGEND

1 HOUR FIRE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE PARTITION: NON-RATED

SMOKE BARRIER - 1 HR FIRE & SMOKE

RATED

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

BID DOCUMENTS

520-317X

Dwg. of fi le s \C o rp o ra te \T e a m s \C

S L E

G

\B

IM

D o c u m e n ts \1

.0

\R e v it \I C

T

B L

D G

P lu m b in g

C D

S .r v t

/1 /2

:4

:1

P M

FX103

5TH FLOOR - FIRE PROTECTION RENOVATE BUILDING 1

BILOXI, MISSISSIPPI

10/27/2023 SCOPRZ AARMEY

134 238

1/8" = 1'-0"FX103

1 5TH FLOOR- FIRE PROTECTION

N O

R T

H

KEYED NOTES:

1. CONNECT TO EXISTING STANDPIPE & DRAIN RISER.

PROVIDE NEW CONTROL VALVE AND INSPECTOR'S TEST

VALVE AND DRAIN ASSEMBLY PER DETAIL ON SHEET PL502.

2. PROVIDE COVERAGE FOR EXISTING LINEN CHUTE AS

REQUIRED PER NFPA 13.

GENERAL NOTES:

1. REFER TO PL601 FOR FIRE PROTECTION NOTES

2. REFER TO ME100 FOR ADDITIONAL FIRE PROTECTION

NOTES.

3. REMOVE EXISTING FIRE HOSE CABINETS, PIPING,

BRACKETS, HANGERS, AND ACCESSORIES. REFER TO

ARCHITECTURAL FOR PATCHING REQUIREMENTS.

SPECIAL CONDITION NOTES:

1. FIRE PROTECTION PIPING FOR THIS FLOOR HAS BEEN

FABRICATED AND IS ON SITE. CONTRACTOR SHALL INSTALL

AND TEST ALL PIPING AS PART OF THIS CONTRACT.

2. REFER TO AS BUILT DRAWINGS IN APPENDIX FOR MORE

INFORMATION INCLUDING WHICH PIPING HAS BEEN

INSTALLED.

3. CONTRACTOR SHALL FIELD VERIFY ON SITE PIPING

PRIOR TO SUBMITTING BIDS.

4. CONTRACTOR SHALL NOTIFY THE OWNER OF ANY

DISCREPANCIES WITH ITEMS ON SITE.

FIRE PROTECTION HAZARD SCHEDULE

HAZARD SYMBOL HAZARD CLASS DESIGN CRITERIA HOSE DURATION SPRINKLER SPACING NOTES

UNO LIGHT 0.10 GPM/SF

OVER 1500SF

100 GPM 30 MIN

MAX 225 SF; MAX 15'

BETWEEN SPRINKLERS;

MAX 7.5' FROM WALL

ALL AREAS ARE LIGHT

HAZARD U.N.O.

ORDINARY HAZARD

GROUP 1

250 GPM 60 MIN

MAX 130 SF;MAX 15'

BETWEEN SPRINKLERS

MAX 7.5' FROM WALL

OH-2

OH-1

ORDINARY HAZARD

GROUP 2

250 GPM 90 MIN

MAX 130 SF;MAX 15'

BETWEEN SPRINKLERS

MAX 7.5' FROM WALL

EH-1 500 GPM 90 MIN

MAX 100 SF;MAX 12'

BETWEEN SPRINKLERS

MAX 6' FROM WALL

EXTRA HAZARD

GROUP 2

EXTRA HAZARD

GROUP 1

0.40 GPM/SF

OVER 2500SF

500 GPM 120 MIN

MAX 100 SF;MAX 12'

BETWEEN SPRINKLERS

MAX 6' FROM WALL

0.15 GPM/SF

OVER 1500SF

0.20 GPM/SF

OVER 1500SF

0.30 GPM/SF

OVER 2500SF

EH-2

S SS

S SS

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22

G

F

E

D

C

B

A

7.4

F.8

F.3

B.4

B.7

D.8

D.2

B.8

B.2

10.8 12.2

EXISTING

5" STANDPIPE

TO AUTOMATIC SPRINKLER

SYSTEM.

EXISTING

1 1/2" DRAIN

EXISTING

4" STANDPIPE

TO AUTOMATIC SPRINKLER

SYSTEM. EXISTING ATTIC IS

WOOD CONSTRUCTION,

SLOPED ROOF, WITH LOWER

POCKETS/CLEARANCE NEAR

THE PERIMETER. SPRINKLER

COVERAGE SHALL INCLUDE ALL

AREAS AS REQUIRED PER

NFPA. REFER TO

ARCHITECTURAL PLANS FOR

ROOF/ATTIC INFORMATION.

EXISTING

1 1/2" DRAIN

ELEVATOR EQUIP ROOM

6B102

CENTRAL STAIR

6B103

ELECTRICAL ROOM

6B100A

ELECTRICAL ROOM

6B100B

OH-1 OH-1

OH-1

OH-1

OH-1

EXISTING ATTIC IS WOOD

CONSTRUCTION, SLOPED

ROOF, WITH LOWER

POCKETS/CLEARANCE NEAR

THE PERIMETER. SPRINKLER

COVERAGE SHALL INCLUDE

ALL AREAS AS REQUIRED PER

NFPA. REFER TO

ARCHITECTURAL PLANS FOR

ROOF/ATTIC INFORMATION.

REMOVE AND RELOCATE EXISTING

SPRINKLER SYSTEM AND PIPING AS

NECESSARY FOR NEW HVAC

SYSTEM INSTALLATION. SPRINKLER

HEADS WHICH ARE REMOVED MUST

BE REPLACED WITH NEW HEADS.

INDICATES FOOTPRINT OF EXISTING

EQUIPMENT ENCLOSURE.

LEGEND

1 HOUR FIRE BARRIER

2 HOUR FIRE BARRIER

SMOKE RESISTIVE PARTITION: NON-RATED

SMOKE BARRIER - 1 HR FIRE & SMOKE

RATED

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

BID DOCUMENTS

520-317X

Dwg. of fi le s \C o rp o ra te \T e a m s \C

S L E

G

\B

IM

D o c u m e n ts \1

.0

\R e v it \I C

T

B L

D G

P lu m b in g

C D

S .r v t

/1 /2

:4

:1

P M

FX104

ATTIC - FIRE PROTECTION RENOVATE BUILDING 1

BILOXI, MISSISSIPPI

10/27/2023 SCOPRZ AARMEY

135 238

1/8" = 1'-0"FX104

1 ATTIC - FIRE PROTECTION

N O

R T

H

KEYED NOTES:

1. CONNECT TO EXISTING STANDPIPE & DRAIN RISER.

PROVIDE NEW CONTROL VALVE AND INSPECTOR'S TEST

VALVE AND DRAIN ASSEMBLY PER DETAIL ON SHEET PL502.

2. PROVIDE COVERAGE FOR EXISTING LINEN CHUTE AS

REQUIRED PER NFPA 13.

GENERAL NOTES:

1. REFER TO PL601 FOR FIRE PROTECTION NOTES

2. REFER TO ME100 FOR ADDITIONAL FIRE PROTECTION

NOTES.

3. REMOVE EXISTING FIRE HOSE CABINETS, PIPING,

BRACKETS, HANGERS, AND ACCESSORIES. REFER TO

Sheets
FX101 - 3RD FLOOR - FIRE PROTECTION
FX102 - 4TH FLOOR - FIRE PROTECTION
FX103 - 5TH FLOOR - FIRE PROTECTION
FX104 - ATTIC - FIRE PROTECTION
PL101 - EXISTING CRAWL SPACE - PLUMBING
PL102 - EXISTING 1ST FLOOR - PLUMBING
PL103 - EXISTING 2ND FLOOR - PLUMBING
PL104 - 3RD FLOOR - PLUMBING
PL105 - 4TH FLOOR - PLUMBING
PL106 - 5TH FLOOR - PLUMBING
PL107 - ATTIC - PLUMBING
PL201 - EXISTING CRAWL SPACE - SANITARY
PL202 - EXISTING PLAN 2ND FLOOR - SANITARY
PL203 - 3RD FLOOR - SANITARY
PL204 - 4TH FLOOR - SANITARY
PL205 - 5TH FLOOR - SANITARY
PL206 - ATTIC - SANITARY
PL301 - EXISTING CRAWL SPACE -MED GAS
PL302 - EXISTING 1ST FLOOR - MED GAS
PL303 - EXISTING 2ND FLOOR - MED GAS
PL304 - 3RD FLOOR - MED GAS
PL305 - 4TH FLOOR - MED GAS
PL306 - 5TH FLOOR - MED GAS
PL307 - ATTIC - MED GAS
PL401 - ENLARGED PLANS - PLUMBING
PL402 - ENLARGED PLANS - PLUMBING
PL403 - ENLARGED PLANS - PLUMBING
PL404 - ENLARGED PLANS - PLUMBING
PL501 - DETAILS - PLUMBING
PL502 - DETAILS - PLUMBING
PL505 - OVERALL SANITARY RISER
PL506 - OVERALL WATER RISER
PL507 - OVERALL MED GAS RISER
PL508 - PLUMBING RISERS
PL509 - PLUMBING RISERS
PL510 - PLUMBING RISERS
PL511 - PLUMBING RISERS
PL601 - SCHEDULES - PLUMBING
PS101 - SITE PLAN - PLUMBING

File details come from the government source that posted it. Updated .