05 Architectural 1a.pdf

PDF 7 MB Posted

Attached to
Biloxi Building 1 Renovation - Biloxi, MS -- Y1DA
Solicitation number
QSE--36C10F24R50025
Issued by

About this file

This pre-solicitation notice seeks qualified contractors to renovate Building 1 in Biloxi, Mississippi. The selected contractor will provide all labor, materials, equipment, supervision, and transportation necessary to complete selective demolition, exterior envelope alterations, and interior renovations on floors 3 through 5 and within crawl spaces and the attic. Upgrades will be made to HVAC, plumbing, electrical, telecommunications, chilled water, and fire protection systems. Limited structural, mechanical, and electrical work will also occur on the underside of the third floor within occupied areas of the second floor. The contractor must monitor the building's foundation system throughout the project duration using a qualified consultant. The Department of Veterans Affairs Office of Construction and Facilities Management will award the contract.

View the file

Other files

File Type Posted
C28_Specifications Vol I (Biloxi Bldg 1 Reno) - 10.27.23.pdf PDF
Building 1 Inventory (b).pdf PDF
05 Architectural 4.pdf PDF
05 Architectural 1b.pdf PDF
01 General.pdf PDF
05 Architectural 2.pdf PDF
Building 1 Inventory (a).pdf PDF
Biloxi VA Reno B1_103287_SET_H.pdf PDF
10 Electrical_1.pdf PDF
13 Reference Drawings.pdf PDF
08 Plumbing_2a.pdf PDF
A-dec Floor Plan - VA Biloxi - Rev 2-24-23-Preliminary.pdf PDF
Compass Headwall 1.11.23.pdf PDF
VA Biloxi Patient Room Footwall Typical Elevation.pdf PDF
09 Mechanical_2.pdf PDF
07 Fire Protection.pdf PDF
A-dec Floor Plan - VA Biloxi - Rev 2-24-23-ELEVATIONS.pdf PDF
000000 Cover Page Appendix.pdf PDF
09 Mechanical_1.pdf PDF
04 Structural 1.pdf PDF
04 Structural 2.pdf PDF
LOCQ7780-03-SWS-Biloxi VA Dental Lab Drawing 1-5.pdf PDF
10 Electrical_2.pdf PDF
05 Architectural 3.pdf PDF
08 Plumbing_1.pdf PDF
Building 1 Inventory (d).pdf PDF
08 Plumbing_2b.pdf PDF
Adec Submittal - VA Biloxi.pdf PDF
11 Telecommunication.pdf PDF
VA Biloxi 3rd Floor Footwall 2-13-23 FINAL-30x42.pdf PDF
Building 1 Inventory (c).pdf PDF
S02_DRAFT SOLICITATION (36C10F24R50025) - 02.07.24.pdf PDF
VA Biloxi 4th Floor Footwall 2-13-23 FINAL-30x42.pdf PDF
C28_Specifications Vol II (Biloxi Bldg 1 Reno) - 10.27.23.pdf PDF
06 Interior.pdf PDF
Pre-Solicitation Notice - Sources Sought Notice - Biloxi Bldg 1 Reno.docx DOCX document
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10.27.2023

FF

L

K

REMOVE

PORTION OF

EXISTING WALL

3710.27.2023

AD502

CHUTE &

SHAFT

REFER TO SHEET AE102 FOR PHASING/SEQUENCING NOTES

APPLICABLE TO WORK ON THIS FLOOR

AD501

E

LAUNDRY

CHUTE

THIRD FLOOR PLAN - DEMOLITION

U

SL

OP

E

SL

OP

E

SLOPESLOPE

w w w

U

U

U U

U

U

U

UU

Y

Y

Y

Y

YX

X X

U

ZZ1ZZ1

CHAPELCHAPEL

BUILDING

BUILD

ING 1

BUILDING 1

XX

X

X

03.10.202310.27.2023

Sim

UP

LAUNDRY

CHUTE

LAUNDRY

CHUTE

FOURTH FLOOR PLAN - EXISTING & DEMOLITION

FIFTH FLOOR PLAN - EXISTING & DEMOLITION

U

4 Sim w w w w w w

Y

Y

Y

Y

Y

Y

Y

Y

X

X

Y

Z

Z

X

X

U

U

U

U

U

U

U U

U

U

U

U

U

U

UU

U

U

ZZ1

ZZ1

ZZ1

ZZ1

D40

Sim D401

13 Sim

D401

D40

U

X

XXX

U X X

XX

X

X

X

X

03.10.202310.27.2023

LAUNDRY

CHUTE

S

U

ATTIC FLOOR PLAN - EXISTING & DEMOLITION

ZZ.1

U

U

U U

SAW CUT AND REMOVE EXISTING

MASONRY WALL AS REQUIRED TO

INSTALL HOLLOW METAL FRAME

AND DOOR. VERIFY EXISTING SUPPORT

CONDITIONS @ FRAME HEAD IS ADEQUATE

S

U

V

V V

Vw

D

D D

V

D w w w w M

C

M

C

C

EXISTING

BUILDING

4210.27.2023

Q

M w

V

V V V

X X X

R

PAINT AND STORE RAILS FOR

STOREFRONT

R PAINT

EXTERIOR PAINTING AND

SILICONE ELASTOMERIC

- SEE DEMOLITION ELEVATION KEYNOTES

ON SHEET AD202

FOR DORMER/ LOUVER

DEMOLITION SEE ELEVATION

6/AD503

AD301

PARTIAL NORTH ELEVATION PARTIAL NORTH ELEVATION

1st Floor

13' - 0" 2nd Floor

3rd Floor

4th Floor

5th Floor

Attic

26' - 0"

0' - 0"

39' - 0"

52' - 0"

66' - 0"

1st Floor

13' - 0" 2nd Floor

3rd Floor

4th Floor

5th Floor

Attic

26' - 0"

0' - 0"

39' - 0"

52' - 0"

66' - 0"

AD505

CLEAN AND PREPARE MASONRY FOR

EXTERIOR PAINTING AND

SILICONE ELASTOMERIC COATING,

SEE DEMOLITION ELEVATION

KEYNOTE ON SHEET AD202

ALL EXISTING STRUCTURAL

MEMBERS TO REMAIN

WOOD FRAMING TO

REMAIN. VERIFY

CONDITION. REPLACE

WHERE IS DETERIORATED

REMOVE ALL WOOD

TRIM

REMOVE PUNCHED WINDOWS

AND WOOD SUPPORTS AT

ATTIC

REMOVE PUNCHED WINDOWS

AND WOOD SUPPORTS AT

ATTIC

CLEAN & PREPARE MASONRY

TYP ALL FLOORS

- SEE DEMOLITION ELEVATION

KEYNOTES ON SHEET AD202

REMOVE PUNCHED WINDOWS

AND WOOD SUPPORTS AT

3RD, 4TH, 5TH FLOORS AND

ATTIC

CLEAN & PREPARE ALL

EXISTING WOOD SURFACES

FOR WATERPROOF COATING

REMOVE, CLEAN, PAINT, AND

STORE RAILS FOR REUSE,

ALL FLOORS TYP

REMOVE SHUTTERS AND

STORE FOR REUSE

REMOVE PUNCHED WINDOWS

AND WOOD SUPPORTS AT

3RD, 4TH, 5TH FLOORS AND

ATTIC

REMOVE ALL GUTTERS AND

DOWNSPOUTS TYP

REMOVE COPPER CAP FLASHING

REMOVE WOOD TRIM

REMOVE AND STORE ALL WOOD

BALUSTERS

METAL FLASHING TO REMAIN

REMOVE WOOD TRIM

OPEN

METAL FLASHING AT ROOF TO

REMAIN

REMOVE WOOD TRIM

REMOVE COPPER CAP FLASHING

PLASTER COLUMN TO

REMAIN

REMOVE SHUTTERS AND

STORE FOR REUSE. TYP

REMOVE PUNCHED WINDOWS

AND WOOD SUPPORTS AT

3RD, 4TH, 5TH FLOORS AND

ATTICCLEAN & PREPARE MASONRY

TYP ALL FLOORS

- SEE DEMOLITION ELEVATION

KEYNOTES ON SHEET AD202

AD212

FOR SECTION THROUGH

INTERMEDIATE MEMBER

@ COLUMN LOCATION

SEE 3/AD212

ENLARGED ELEVATION / SECTIONENLARGED ELEVATION

ENLARGED ELEVATION / SECTION

ENLARGED ELEVATION / SECTION ENLARGED ELEVATION / SECTION

ENLARGED ELEVATION / SECTION

CLEAN & PREPARE MASONRY

TYP ALL FLOORS

- SEE DEMOLITION ELEVATION

KEYNOTES ON SHEET AD202

CLEAN & PREPARE MASONRY

TYP ALL FLOORS

- SEE DEMOLITION ELEVATION

KEYNOTES ON SHEET AD202

WOOD FRAMINGE TO

REMAIN, REMOVE

AND REPLACE IF

DETERIORATED.

TYPICAL AT PORCH

REMOVE ALL

WOOD BALUSTERS

TO BE STORED FOR

REUSE

18 21 20 19 18 14 13

2 3 4 20

3 2 B C F

9 5 4 10 11 12 13

AREA OF EXISTING

PAINTED

TONGUE AND GROOVE

COLUMN SURROUND

TO BE REMOVED

REMOVE EXISTING PUNCHED

WINDOW UNIT IN ITS ENTIRETY

INCLUDING ALL SURROUNDING

WOOD SUPPORTS

F

THIRD FLOOR ELEVATION THIRD FLOOR ELEVATION THIRD FLOOR ELEVATION THIRD FLOOR ELEVATION THIRD FLOOR ELEVATION

THIRD FLOOR ELEVATION THIRD FLOOR ELEVATION THIRD FLOOR ELEVATION

THIRD FLOOR ELEVATION THIRD FLOOR ELEVATION THIRD FLOOR ELEVATION THIRD FLOOR ELEVATION

THIRD FLOOR ELEVATION THIRD FLOOR ELEVATION THIRD FLOOR ELEVATION

AT 5TH

FLOOR

ONLY

SEE STRUCTURAL

DRAWING, SHEET S404