About this file
This document is an Amendment #1 Q&A for a federal contract opportunity, providing clarifications for multiple tasks related to electrical and lighting installations. The Q&A covers four distinct tasks with specific details about Remote Launch Mechanism (RLM) and Material Tracking (MAT) sites:
Task 1 confirms no electrical work is required. Task 2 addresses fixture replacement, with suppliers indicating a specific fixture (AV-OL-FL810-UM-RIR) is no longer available. The government will provide a cut sheet for new fixtures and a dusk-to-dawn controller. Four additional RLM locations are located near the Jack Mountain Multi Use Range, and contractors can visit sites during morning mandatory shutdown by coordinating with the Contracting Officer's Representative (COR). Task 3 and Task 4 involve electrical installations, including exposed 1" GRS conduit along movers, power tapping into existing panels, and installing switched auxiliary power receptacles. The amendment provides specific guidance on conduit routing, power sources, and installation requirements for these locations.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140D0425R0119_Amd_0001.pdf | ||
| B08_SOL_SLMU_Resilience_Range_Repairs_PDF_Main_9-8-2025_0001.pdf | ||
| Sol_140D0425R0119.pdf | ||
| A06_DS_Attachment_02_Water_Points_Map_8-7-2025.pdf | ||
| A06_DS_Attachment_03__EXHIBITS_8_7_2025.pdf | ||
| A04_SOW_Fort_Hood_SLMU_Environmental_Resilience_Range_Repair_8_7_2025.pdf | ||
| A06_DS_Attachment_01__IMPACTS_ON_OTHER_RANGES.pdf | ||
| B08_SOL_SLMU_Resilience_Range_Repairs_PDF_Main_DC.pdf | ||
| B09_SA_Amendment_5_Additional_Q_A.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Amendment #1 Q&A
Task 1 Please confirm there is no electric work associated with this Task.
Correct. No Electrical Work in Task 1
Task 2 The suppliers say fixture AV-OL-FL810-UM-RIR is no longer available.
Correct. A cut sheet on the fixtures will be furnished. A dusk to dawn controller will need to be installed at each RLM with using the attached light cut sheet.
Will you provide a drawing of the existing electrical installation for the RLM. It is not shown in drawings?
No. The attached photos show the typical for the nine (9) typical (APR) it is RLMs for para 4.3.2.1.
contractor responsible for design for electrical functions stated in para 4.3.2.2.
What is the location of the four remaining RLM that are not shown on the Sugarloaf site drawing?
These RLMs are located down range of Jack Mountain Multi Use (JMMU) Range located off West Range Road mile marker 8.5 then up to 4 miles down range. the Military Grid Reference System locations are provided in the solicitation documents.
Will contractors be able to visit all RLM locations?
Yes, during morning mandatory shut down with government escort. Contact COR Tim Bauman 254-432- 1386 to set up site visit.
Will any of the RLM work be required to be performed during mandatory shut down? See schedule in exhibit J .
Yes, work at the four RLM on JMMU range.
Is there a power feed (panel) for the battery charger located on the west end of MAT 2 and the east end of MAT 8. Please confirm No, battery chargers currently installed. The previous target system used a bus-bar that ran along the target tracks. There is no existing power on the west end of MAT2 nor on the East end of MAT8. there is a power panel on the East end of MAT2 and West end of MAT8.
Task 3 The 20 Amp breaker feeding the existing battery charger is located on the east end of MAT 2 and the west end of MAT 8. Please confirm.
No existing battery chargers installed. you will need to tap into the existing power panel at the mover wall.
Will the 1” GRS conduit be installed exposed and run the length of the mover from the east end to the west end of MAT 2 and from the west end to the east end of MAT 8? Please confirm That is correct.
Will the 1” GRS conduit be installed on the MAT retaining wall from east to west on MAT 2 and west to east on MAT 8? Please confirm.
The conduit is to be run along the face of the MAT Retaining wall.
Will there be any trenching with the task 3 installation? Please advise.
There will be no trenching for Task 3.
Task 4 Is there a 20-amp (panel) power source at the RLM location at MAT 2 and Mat 8 to provide power into the for the switched auxiliary power receptacle? Please advise.
Yes, you will need to tap into the existing power panel at the mover wall.
What panel and circuit will the (APR) feed from? Please advise.
Disregard (APR). It is to have a switch and a power receptacle at the RLM that the RLM will plug into.
EOL SERIES (L-810) OBSTRUCTION LIGHT
SINGLE AND DOUBLE FIXTURE
INSTALLATION INSTRUCTIONS AND PARTS LIST
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
IF 1556
Cooper Industries Inc. IF 1556
Crouse-Hinds Division Rev 1
PO Box 4999, Syracuse, New York 13221 • U.S.A. New 2/08
Copyright© 2008, Cooper Industries, Inc. Page 1
All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable. The accuracy or completeness thereof are not guaranteed. In accordance with Crouse-Hinds "Terms and Conditions of Sale", and since conditions of use are outside our control, the purchaser should determine the suitability of the product for his intended use and assumes all risk and liability whatsoever in connection therewith.
INSTALLATION - SINGLE HEAD UNITS
(A) Single fixtures as supplied are fully assembled with the exception of the lamp. To install or replace the lamp (7), remove the clamp band (5) and globe (4). The globe (4) can be supported by the supplied attached tether. Inspect o-ring (2) and other internal components and replace as necessary.
(B) Assemble the locknut (13) to the mounting column (20) (see figure 1) with the notched locking surface on the top side and threaded on to a depth of one inch. Connect wires (9, 10 and if -
GR or -CSA version, item 11) to the appropriate source. (NOTE:
white wire (9) is connected to the lamp socked shell (8)).
(C) For P/N 40940, position the fixture on the mounting column (20)
(See figure 1) and loosen the three binding screws (6) half a turn. Thread only the globe support hub (12) (to avoid twisting wires) to full thread depth and secure the locknut (13). With the globe support (1) fully bottomed on the hub (12), tighten all three binding screws (6).
(D) For P/N 50033, insert 90° elbow (14) into globe support (1) (see figure 2). With the globe support (1) fully bottomed on the elbow
(14), tighten all three binding screws (6).
WARNING
De-energize circuit before relamping or working on fixture
FIGURE - 1 P/N 40940
FIGURE 2 - P/N 50033FIGURE 3 - P/N 50021
Cooper Industries Inc. IF 1556
Crouse-Hinds Division Rev 1
PO Box 4999, Syracuse, New York 13221 • U.S.A. New 2/08
Copyright© 2008, Cooper Industries, Inc. Page 2
ITEM NO. PART NO. QTY DESCRIPTION
1 40948 1 GLOBE SUPPORT
2 10035-37 1 SEAL
3 10048-37 A/R RTV, CLEAR
50131-R 1 GLOBE & TETHER ASSY, RED
50131-B 1 GLOBE & TETHER ASSY, BLUE
50131-Y 1 GLOBE & TETHER ASSY, YELLOW
50131-G 1 GLOBE & TETHER ASSY, GREEN
50131-C 1 GLOBE & TETHER ASSY, CLEAR
5 50107 1 CLAMP BAND
6 10A10-025D24 3 SCREW, HEX HD., TYPE F, 1/4-20 X 3/4” LONG
10047-1558 1 LAMP, 69 WATT, 120 VOLT
10047-1577 1 LAMP, 116 WATT, 120 VOLT
10047-2145 1 LAMP, 116 WATT, 230 VOLT
8 10047-1559 1 SOCKET, LAMP
9 50030W 1 WIRE ASSY, #16 AWG, WHITE
10 50030 1 WIRE ASSY, #16, BLACK
11 50095 1 GROUND WIRE ASSY (-GR & -CSA)
12 40936 1 HUB, GLOBE SUPPORT
13 10037-322 1 LOCKNUT (1.00”)
14 10037-332 1 ELBOW, 90° MALE / FEMALE
15 50098-1 1 INSULATOR, SOCKET (-CSA)
13 50083 2 NIPPLE, 1” NPT - ONE END ONLY
17 10037-326 1 HOUSING, CONDULET
18 10037-571 1 COVER, SNAPTIGHT
19 10H27-013D10 1 SCREW, RD. HD., #6-32X5
⁄16, SELF-TAP TYPE “F” SST
20 NOT SUPPLIED 1 MOUNTING COLUMN
PARTS LIST
PART NO. 40940 - OBSTRUCTION LIGHT, L- 810 SINGLE
PART NO. 50021 - OBSTRUCTION LIGHT, L- 810 DOUBLE
PART NO. 50033 - OBSTRUCTION LIGHT, L- 810 SINGLE SIDE HUB
* - DESIGNATES THESE ITEMS TO HAVE THE QUANTITY DOUBLED FOR USE ON A 50021 LIGHT
INSTALLATION - DOUBLE FIXTURE P/N 50021
(A) Lamp and globe assembly is the same as the single fixture procedure.
(B) Remove housing cover (18) from condulet housing (17).
Position one light fixture at either end of condulet housing and feel lead wires into the center section of housing.
Thread light fixture into end of housing as far as it will go, aligning light fixture in a vertical position. Do this for both fixtures then re-assemble cover (18) to condulet housing
(17).
FIGURE 4 - GROUNDING WIRE (-GR)
MKR-LTG1-0IR
L-810(L) LED Obstruction Light with Infrared (IR)
The MKR-LTG1-0IR Single Obstruction Light integrates visible Red LEDs and Infrared LEDs into a single L-810(L).
Infrared energy (IR) can enhance compatibility with Night Aviator’s Vision Imaging Systems (ANVIS) and Night Vision Goggles (NVG). Precision molded Fresnel Optics produce a low ground scatter tower lighting solution. The die cast aluminum base provides 3/4 inch conduit hubs for side or bottom mounting. Multiple 9kA MOVs and a 20kA gas plasma discharge tube provide robust surge suppression.
Night Vision Goggles (NVG) and Aviator's Night Vision Imaging Systems (ANVIS) translate infrared energy (IR) into brightness variations on a human visible display. These systems utilize various filters and technology that affect their sensitivity to infrared energy (IR) of different wavelengths. International Tower Lighting, LLC (ITL) makes no claim or representation that the infrared energy (IR) emitted by ITL obstruction lights is visible to any NVG, ANVIS or other night vision imaging system. In no event shall International Tower Lighting, LLC (ITL) or any of its representatives be liable for any damages, including, without limitation, direct, consequential, indirect, punitive, incidental or special damages, in connection with the infrared energy (IR) emitted by ITL obstruction lights and/or whether any NVG or ANVIS can detect such Infrared energy (IR) or whether the infrared energy (IR) emitted by ITL obstruction lights is visible to any NVG, ANVIS or other night vision imaging system, regardless of the form of action.
Features Integrated Infrared Emitters can enhance compatibility with Aviator’s
Night Vision Imaging Systems (ANVIS) and Night Vision Goggles (NVG).
Rugged die cast aluminum base.
Stainless steel latches and hardware.
3/4 Inch conduit entrance, side and bottom hubs.
Modular replaceable power supply.
Power supply operates from 100 to 240 Vac, 50/60Hz
Power Factor Corrected (PFC), PF≥0.9 @ 120Vac
Double obstruction light version available, ITL part number MKR-LTG2-0IR.
Specifications
Specifications: ETL Certified to
AC150/5345-43,
Type L-810 (L) / L-810F (L), TVOC Transport Canada CAR 621
Intensity: 32.5 effective candelas (min.), Red
4 mW/sr (min), 800-900nm, Infrared
Height: 7.5 Inches (19.1 cm)
Width: 5.4 Inches (13.7 cm)
Weight: 2.0 lbs. (0.9 Kg)
Power: 100 to 240 Vac, 50 / 60 Hz, 7W
Temperature: -40°C to +55°C
Humidity: less than 95%, non-condensing R ev .3
Phone: +1 (615) 256-6030 Toll Free: +1 (866) 624-8309 La Vergne, TN 37086 USA, Copyright © 2019 - 2021
File details come from the government source that posted it. Updated .