This package includes architectural and engineering drawings, specifications, and a solicitation for the East Potomac Maintenance Yard Fuel Station Rehabilitation project located in Washington, DC. The project involves renovating an existing fuel station and control building, including new fuel storage tanks, dispensers, piping, and controls. Bids are due by January 15, 2023, with work to commence in April and be complete by October 2023. The estimated cost is between $500,000 and $1 million. The National Park Service is the contracting agency.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REHABILITATION OF THE FUEL SYSTEMS
EAST POTOMAC MAINTENANCE YARD
EAST
POTOMAC
PARK
PROJECT ADDRESS: 500 BUCKEYE DRIVE, SW, WASHINGTON, DC 20024
WARNING - EROSION & SEDIMENT CONTROL SHALL BE STRICTLY ENFORCED !
HARD - SURFACE INSTALLATION
PLAN VIEW
FILTER SOCK - 2
CONSTRUCTION SPECIFICATIONS
HARD SURFACE INSTALLATION SECTION
CURB INLET PROTECTION
STORM DRAIN INLET PROTECTION
CONSTRUCTION SPECIFICATIONS
ISOMETRIC SECTION A-A
SUMP PIT
CONSTRUCTION SPECIFICATIONS
ELEVATION
* THESE NUMBERS SHALL BE USED FOR PERMIT PURPOSES ONLY
AND NOT FOR BIDDING.
AREA LOCATION
OFFSITE WASTE/BORROW
TOTAL FILL
TOTAL CUT
AREA DISTURBED
CUBIC YARDS FILL
CUBIC YARDS *
CUBIC YARDS *
AC0.111
N/A
TOTAL AREA OF SITE 373 WARNING - EROSION &
SEDIMENT CONTROL
SHALL BE STRICTLY
ENFORCED !
AC
BEDDING
AGGREGATE
OD OD
COMPACTED BACKFILL
4" MIN
MARKER TAPE
31 20 00 EARTH MOVING
SEE SPECIFICATION
INITIAL BACKFILL
NOTES
1) WHERE THE TRENCH BOTTOM IS IN ROCK, IT SHALL BE EXCAVATED TO A MINIMUM OF 6"
BELOW THE BOTTOM OF THE PIPE AND BACKFILLED WITH BEDDING MATERIAL.
2) WHERE PIPE FOUNDATIONS ARE YIELDING, PIPE SHALL BE BEDDED ON A MINIMUM 6"
BEDDING MATERIAL
24" MIN
NO. 57 OR 58
DETAIL / PLAN
BLDG SECTION CUT
DRAWING REFERENCE
SHEET REFERENCE
DRAWING REFERENCE
SHEET REFERENCE
INTERIOR ELEVATION DETAIL CUT
DRAWING REFERENCE
SHEET REFERENCE
DRAWING REFERENCE
SHEET REFERENCE
WALL SECTION CUT
DRAWING REFERENCE
SHEET REFERENCE
DRAWING REFERENCE
SHEET REFERENCE
EXTERIOR ELEVATION
ROOM NAME / NUMBER
DOOR NUMBER
WALL TYPES
WINDOW NUMBER
CONCRETE
DIMENSIONAL LUMBER
(SIZE AS INDICATED)
STEEL
DISCONTINUOUS LUMBER
(SIZE AS INDICATED)
MATERIAL SYMBOLS
WORK POINT
NEW ELEVATION
EXISTING ELEVATION
CMU
BATT INSULATION
KEYNOTE
EARTH
ALUMINUM
WOOD
PLYWOOD
STONE
SYMBOLS
BRICK
GROUT
GRAVEL
PARTICLE BOARD
PLASTIC
GLASS
SHIM
GYPSUM BOARD / PLASTER
SEALANT & BACKER ROD
(SIZE AS INDICATED)
METAL STUD
METAL TRACK
ACOUSTICAL CEILING
BRASS/BRONZE
PLASTER AND LATH
NATIONAL PARK SERVICE INTERIOR REGION 1 NATIONAL CAPITAL AREA
DESIGN AND PROJECT MANAGEMENT
UNITED STATES
OF
SHEET
DWG. NO.
DATE
DEPARTMENT OF THE INTERIOR
SUB SHEET NUMBERTITLE OF DRAWING
Mark Sheet InitialDateREVISION
DESIGNED
DRAWN
CHECKED
TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
21000 ATLANTIC
EAST POTOMAC MAINTENANCE YARD
REHABILITATION OF THE FUEL SYSTEMS
NATIONAL MALL AND MEMORIAL PARKS (NAMA)
DVA
DVA
JNW
165425
254579
PMIS#
NOT FOR
CONSTRUCTION DULLES, VA 20166
BOULEVARD, SUITE 400
(703) 450 0800 www.alphacorporation.com
08.27.2021
A 001
SYMBOLS AND ABBREVIATIONS
RO ROUGH OPENING
S SOUTH, SEAL
SC SOLID CORE
SCHED SCHEDULE
SECT SECTION
SF SQUARE FEET
SHT SHEET
SIM SIMILAR
SLL SOUND / LIGHT LOCK
SPEC(S) SPECIFICATION(S)
SQ SQUARE
SS STAINLESS STEEL
ST STAINLESS
STD STANDARD
STL STEEL
STN STAIN
STO STORAGE
STRUC STRUCTURAL
SUSP SUSPENDED
SYM SYMMETRICAL
SYS SYSTEM
T TREAD
T&G TONGUE AND GROOVE
T.O. TOP OF
TECH TECHNOLOGY
TEL TELEPHONE
TEMP TEMPERED
THK THICK(NESS)
THRESH THRESHOLD
TOC TOP OF CURB
TOL TOLERANCE
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL
TRANS TRANSPARENT
TV TELEVISION
TYP TYPICAL
UL UNDERWRITER'S LABORATORY
UNFIN UNFINISHED
UON UNLESS OTHERWISE NOTED
VAR VARIES
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VU VENTILATION UNIT
VWC VINYL WALLCOVERING
W WIDE, WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDW WINDOW
WH WALL HUNG
WP WORK POINT
WT WEIGHT
WWF WELDED WIRE FABRIC
LH LEFT HAND
LL LIVE LOAD
LP LOW POINT
LTG LIGHTING
LTL LINTEL
MAS MASONRY
MATL MATERIAL(S)
MAX MAXIMUM
MECH MECHANICAL
MED MEDIUM
MEMB MEMBRANE
MFR MANUFACTURE(R)
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTG MOUNTING
MTL METAL
JC JANITOR CLOSET
NAT NATURAL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NPS NATIONAL PARK SERVICE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPP HD OPPOSITE HAND
PAR PARALLEL
PART PARTITION
PC PRECAST
PERF PERFORATE(D)
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLWD PLYWOOD
PNL PANEL(ED)
PR PAIR
PREP PREPARE (SURFACE)
PROV PROVIDE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT
PTD PAINT(ED)
PVMT PAVEMENT
QTY QUANTITY
R RADIUS, RISER
RB RUBBER BASE
REF REFERENCE
REINF REINFORCED
REQ /
REQS
REQUIREMENT(S)
REQD /
REQ'D
REQUIRED
RES RESILIENT
RET RETAINING
REV REVISION(S) / REVISE(D)
RFG ROOFING
RH RIGHT HAND
RL RAIN LEADER
RM ROOM
ENCL ENCLOS(E,URE)
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE(D)
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED, EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FAS FASTEN(ER)
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FACE
FGL FIBERGLASS
FHC FIRE HOSE CABINET
FIN(S) FINISH(ES)
FIXT FIXTURE
FL FLOOR(ING)
FLAM FLAMMABLE
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOS FACE OF STUDS
FP FIREPROOF(ING)
FR FRAME(D,ING)
FT FEET
FTG FOOTING
FUR FURR(ED,ING)
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACT(OR)
GL GLASS, GLAZING
GOVT GOVERNMENT
GT GROUT
GWB GYPSUM WALLBOARD
H HIGH
HC HOLLOW CORE
HDR HEADER
HDWD HARDWOOD
HDWR HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATION & AIR
CONDITIONING
ID INSIDE DIAMETER
IN INCH(ES)
INCAN INCANDESCENT
INCL INCLUDE(D,ING)
INSUL INSULATION, INSULATED
INT INTERIOR
JAN JANITOR
JT(S) JOINT(S)
N NORTH
KIT KITCHEN
LAM LAMINATE(D)
LAV LAVATORY
LBL LABEL
LF LINEAR FOOT
A/C AIR CONDITIONING
ABA ARCHITECTURAL BARRIERS ACT
ABT ABOUT
ACCESS ACCESSIBLE
ACM ASBESTOS CONTAINING MATERIAL
ACOUS ACOUSTIC
ACP ACOUSTICAL CEILING PANEL
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AGG AGGREGATE
ALT ALTERNATE
ALUM ALUMINIUM
APPROX APPROXIMATELY
ARCH ARCHITECT(URAL, URE)
ASPH ASPHALT(IC)
ASSOC ASSOCIATED
AUTO AUTOMATIC
AWP ACOUSTICAL WALL PANEL
BD BOARD
BIT BITUMINOUS, BITUMEN
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BS BOTH SIDES
BTWN BETWEEN
CAB CABINET
CEM CEMENT
CJ CONTROL JOINT
CLG CEILING
CLO CLOSET
CLR CLEAR(ANCE)
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
COL COLUMN
COM COMMUNICATIONS
CONC CONCRETE
COND CONDITION
CONFIG CONFIGURATION
CONST CONSTRUCTION
CONT CONTINUOUS
COORD COORDINATE
CORR CORRIDOR
CPT CARPET(ED)
CT CERAMIC TILE
CTR CENTER
D DEEP
DEG DEGREE
DF DRINKING FOUNTAIN
DIAG DIAGONAL
DIAM DIAMETER
DIM DIMENSION
DIV DIVISION
DN DOWN
DR DOOR
DTL DETAIL
DWG(S) DRAWING(S)
E EAST
E-P EPOXY PAINT
EA EACH
EJ EXPANSION JOINT
EL ELEVATION (TOPO)
ELEC ELECTRICAL
ELEV ELEVATION (ARCH),ELEVATOR
EMER EMERGENCY
ABBREVIATIONS MATERIALS & SYMBOLS
481 SF 366 SF
69 SF
277 SF
61 SF
EXISTING BUILDING
FUEL CONTROL BUILDING
(REFER TO SPECIFICATION
SECTION 133423.16 "FUEL CONTROL BUILDING")
CANOPY ABOVE,
REFER TO STRUCTURAL DRAWINGS
FOR ADDITIONAL INFORMATION.
GASOLINE TANK AND ACCESS STAIR,
REFER TO CIVIL AND STRUCTURAL DRAWINGS
FOR ADDITIONAL INFORMATION.
DIESEL TANK AND ACCESS STAIR,
REFER TO CIVIL AND STRUCTURAL DRAWINGS
FOR ADDITIONAL INFORMATION.
80 SF
19' - 1" ± 45' - 1" ±
9' - 9" 10' - 6" 9' - 9"
30' - 0"
EQ 10' - 0" EQ
CODES USED AS A BASIS FOR THE DESIGN:
2017 DC CONSTRUCTION CODE, 2015 INTERNATIONAL BULDING CODE, 2015 INTERNATIONAL EXISTING BUILDING CODE
CHAPTER 3 - USE AND OCCUPANCY CLASSIFICATION
FUEL CONTROL BUILDING: 312, GROUP U: UTILITY AND MISCELLANEOUS
MAINTENANCE BUILDING: 311.2, GROUP S-1: MOTOR VEHICLE REPAIR GARAGES
CHAPTER 5 - GENERAL BUILDING HEIGHTS AND AREAS
TABLE 504.3 - ALLOWABLE BUILDING HEIGHT TYPE II-B NONSPRINKLERED
ALLOWED: 55 FT
EXISTING, PROVIDED: 25' - 0" +/- AT MAINTENANCE BUILDING
PROVIDED: 10' - 0" AT FUEL CONTROL BUILDING
TABLE 504.4 - ALLOWABLE NUMBER OF STORIES ABOVE GRADE TYPE II-B NONSPRINKLERED
ALLOWED: 2
PROVIDED: 1
TABLE 506.2 - ALLOWABLE AREA DETERMINATION TYPE II-B NONSPRINKLERED
ALLOWED: 17500 SF
EXISTING, PROVIDED: 1254 SF AT MAINTENANCE BUILDING
PROVIDED: 80 SF AT FUEL CONTROL BUILDING
CHAPTER 6 - TYPES OF CONSTRUCTION
TYPE II-B EXISTING STRUCTURAL WALLS ARE MADE OF CONCRETE-MASONRY UNITS.
EXISTING ROOF FRAMING IS TREATED WOOD RAFTERS.
OTHER ELEMENTS ARE CMU, METAL STUDS, GYPSUM WALLBOARD, OR PVC PANELS.
TYPE II-B NEW FUEL CONTROL BUILDING IS MADE OF PRE-FABRICATED GALVANIZED STEEL WITH INSULATION
CHAPTER 8 - INTERIOR FINISHES
TABLE 803.11 - INTERIOR WALL AND CEILING FINISH REQUIREMENTS S OCCUPANCY
INTERIOR EXIT STAIRWAYS AND PASSAGEWAYS: CLASS "B"
CORRIDORS AND ENCLOSURE FOR EXIT ACCESS: CLASS "B"
ROOMS AND ENCLOSED SPACES: CLASS "C"
U OCCUPANCY - NO RESTRICTIONS
CHAPTER 10 - MEANS OF EGRESS
1004 - DESIGN OCCUPANT LOAD
INDUSTRIAL AREAS - 100 GROSS SF / OCCUPANT
MAINTENANCE BUILDING: 1254 SF PROVIDED / 100 = 13 OCCUPANTS TOTAL
FUEL CONTROL BUILDING: 80 SF PROVIDED / 100 = 1 OCCUPANT TOTAL
1005.3.2 OTHER EGRESS COMPONENTS
MAINTENANCE BUILDING: 13 * 0.2" EGRESS CAPACITY FACTOR = 2.6", 108" PROVIDED.
FUEL CONTROL BUILDING: 1 * 0.2" EGRESS CAPACITY FACTOR = 0.2", 32" PROVIDED.
TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY S OCCUPANCY WITHOUT SPRINKLER SYSTEM
OCCUPANT LOAD < 29 AND MAX COMMON PATH OF TRAVEL < 100'
U OCCPANCY WITHOUT SPRINKLER SYSTEM
OCCUPANT LOAD < 49 AND MAX COMMON PATH OF TRAVEL < 100'
1009.1 ACCESSIBLE MEANS OF EGRESS REQUIRED
MAINTENANCE BUILDING: EXCEPTION 1 - ACCESSIBLE MEANS OF EGRESS ARE NOT REQUIRED TO BE PROVIDED IN EXISTING BUILDINGS.
FUEL CONTROL BUILDING: 1103.2.4 - GROUP U OCCUPANCIES ARE NOT REQUIRED TO COMPLY
1010.1.2 DOOR SWING
EXCEPTION 1 - PRIVATE GARAGES, OFFICE AREAS, FACTORY AND STORAGE AREAS WITH AN OCCUPANT LOAD OF 10 OR LESS.
WASHDOWN AREA, ROOM 100A, 481 SF PROVIDED, 5 OCCUPANTS < 10
SWINGING DOOR PROVIDED INSIDE OF MANUAL ROLL-UP DOOR 100A-1.
SWINGING DOOR PROVIDED AT FUEL CONTROL BUILDING.
NATIONAL PARK SERVICE INTERIOR REGION 1 NATIONAL CAPITAL AREA
DESIGN AND PROJECT MANAGEMENT
UNITED STATES
OF
SHEET
DWG. NO.
DATE
DEPARTMENT OF THE INTERIOR
SUB SHEET NUMBERTITLE OF DRAWING
Mark Sheet InitialDateREVISION
DESIGNED
DRAWN
CHECKED
TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
21000 ATLANTIC
EAST POTOMAC MAINTENANCE YARD
REHABILITATION OF THE FUEL SYSTEMS
NATIONAL MALL AND MEMORIAL PARKS (NAMA)
DVA
DVA
JNW
165425
254579
PMIS#
NOT FOR
CONSTRUCTION DULLES, VA 20166
BOULEVARD, SUITE 400
(703) 450 0800 www.alphacorporation.com
08.27.2021
A 002
CODE COMPLIANCE PLAN
REFERRED FROM:1/8" = 1'-0"A-002 A-201
1 CODE COMPLIANCE PLAN
45' - 1" ±
100-2100A-2
100A-1 100-1
17' - 0 1/2"
:TYP
NATIONAL PARK SERVICE INTERIOR REGION 1 NATIONAL CAPITAL AREA
DESIGN AND PROJECT MANAGEMENT
UNITED STATES
OF
SHEET
DWG. NO.
DATE
DEPARTMENT OF THE INTERIOR
SUB SHEET NUMBERTITLE OF DRAWING
Mark Sheet InitialDateREVISION
DESIGNED
DRAWN
CHECKED
TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
21000 ATLANTIC
EAST POTOMAC MAINTENANCE YARD
REHABILITATION OF THE FUEL SYSTEMS
NATIONAL MALL AND MEMORIAL PARKS (NAMA)
DVA
DVA
JNW
165425
254579
PMIS#
NOT FOR
CONSTRUCTION DULLES, VA 20166
BOULEVARD, SUITE 400
(703) 450 0800 www.alphacorporation.com
08.27.2021
AD 101
DEMOLITION PLANS
02-01 REMOVE EXISTING ROOFING SYSTEM AND
UNDERLAYMENT DOWN TO DECK
02-02 REMOVE PORTION OF EXISTING SLAB,
INCLUDING EXISTING VEHICLE LIFT, PITS, AND
TRENCH DRAIN. PREPARE AREA FOR NEW
SLAB. SEE STRUCTURAL DRAWINGS FOR
ADDITIONAL INFORMATION.
02-04 REMOVE PORTION OF EXISTING GWB CEILING
AS SHOWN. PATCH AND REPAIR PORTIONS OF
CEILING SUPPORT SYSTEM AS REQUIRED TO
PROVIDE CONTINUOUS, SECURE ATTACHMENT
FOR NEW FRP CEILING SYSTEM,
CEILING-MOUNTING ELECTRICAL EQUIPMENT,
AND CEILING-MOUNTED CLEANING EQUIPMENT.
SEE NEW WORK PLAN FOR ADDITIONAL
INFORMATION.
02-07 REMOVE EXISTING GUTTER AND DOWNSPOUTS.
02-08 REMOVE EXISTING LIGHT FIXTURE. SEE
ELECTRICAL DEMOLITION DRAWINGS FOR
ADDITIONAL INFORMATION.
02-09 REMOVE EXISTING CEILING-MOUNTED OIL AND
LUBE HEADER. SALVAGE FOR RE-USE. SEE
MECHANICAL DRAWINGS FOR ADDITIONAL
INFORMATION.
REFERRED FROM:1/8" = 1'-0"AD-101 A-201
1 DEMOLITION FLOOR PLAN
REFERRED FROM:1/8" = 1'-0"AD-101 A-201
2 DEMOLITION REFLECTED CEILING PLAN
REFERRED FROM:1/8" = 1'-0"AD-101 A-201
3 ROOF DEMOLITION PLAN
SHEET NOTES
0'-0" MATCH EXISTING
19' - 1"±
0'-0" MATCH EXISTING
19' - 1"±
5' - 0" 3' - 0"
1' - 8" 5' - 0"
0'-0" MATCH EXISTING
19' - 1"±
0'-0" MATCH EXISTING
19' - 1"±
NATIONAL PARK SERVICE INTERIOR REGION 1 NATIONAL CAPITAL AREA
DESIGN AND PROJECT MANAGEMENT
UNITED STATES
OF
SHEET
DWG. NO.
DATE
DEPARTMENT OF THE INTERIOR
SUB SHEET NUMBERTITLE OF DRAWING
Mark Sheet InitialDateREVISION
DESIGNED
DRAWN
CHECKED
TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
21000 ATLANTIC
EAST POTOMAC MAINTENANCE YARD
REHABILITATION OF THE FUEL SYSTEMS
NATIONAL MALL AND MEMORIAL PARKS (NAMA)
DVA
DVA
JNW
165425
254579
PMIS#
NOT FOR
CONSTRUCTION DULLES, VA 20166
BOULEVARD, SUITE 400
(703) 450 0800 www.alphacorporation.com
08.27.2021
AD 201
DEMOLITION ELEVATIONS
SHEET NOTES
REFERRED FROM:1/8" = 1'-0"AD-201 A-002
2 NORTH EXTERIOR ELEVATION - DEMOLITION
REFERRED FROM:1/8" = 1'-0"AD-201 A-002
4 SOUTH EXTERIOR ELEVATION - DEMOLITION
REFERRED FROM:1/8" = 1'-0"AD-201 A-002
1 WEST EXTERIOR ELEVATION - DEMOLITION
REFERRED FROM:1/8" = 1'-0"AD-201 A-101
3 EAST EXTERIOR ELEVATION - DEMOLITION
02-10 REMOVE PORTION OF EXISTING MASONRY WALL
AS REQUIRED TO PROVIDE AN OPENING FOR
NEW MECHANICAL EQUIPMENT. COORDINATE
FINAL SIZE OF OPENING WITH SELECTED
EQUIPMENT. SEE STRUCTURAL AND
MECHANICAL DRAWINGS FOR ADDITIONAL
INFORMATION.
23-05 EXISTING THRU-WALL PROPELLER FAN.
EAST POTOMAC MAINTENANCE BUILDING
EXISTING BUILDING
EXISTING BUILDING
BUILDING
TRAILER
CANOPY,
REFER TO STRUCTURAL DRAWINGS
FOR ADDITIONAL INFORMATION.
FUEL
DISPENSERS
EXISTING
GRAVEL
CONCRETE
PAD
SCOPE OF ARCHITECTURAL WORK
SEE SHEETS AD-101 AND A-101 FOR ADDITIONAL INFORMATION.
GASOLINE TANK AND
ACCESS STAIR
DIESEL TANK AND
ACCESS STAIR
FUEL CONTROL BUILDING
(REFER TO SPECIFICATION
SECTION 133423.16
"FUEL CONTROL BUILDING")
DOOR AND WINDOWS TO BE PROVIDED
BY PRE-FAB CONTROL BOOTH MANUFACTURER.
BOLLARD, TYP.
EQ.A EQ.A
10' - 0"
" EQ.B EQ.B EQ.B EQ.B
NOTE: SEE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
NATIONAL PARK SERVICE INTERIOR REGION 1 NATIONAL CAPITAL AREA
DESIGN AND PROJECT MANAGEMENT
UNITED STATES
OF
SHEET
DWG. NO.
DATE
DEPARTMENT OF THE INTERIOR
SUB SHEET NUMBERTITLE OF DRAWING
Mark Sheet InitialDateREVISION
DESIGNED
DRAWN
CHECKED
TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
21000 ATLANTIC
EAST POTOMAC MAINTENANCE YARD
REHABILITATION OF THE FUEL SYSTEMS
NATIONAL MALL AND MEMORIAL PARKS (NAMA)
DVA
DVA
JNW
165425
254579
PMIS#
NOT FOR
CONSTRUCTION DULLES, VA 20166
BOULEVARD, SUITE 400
(703) 450 0800 www.alphacorporation.com
08.27.2021
AS 101
SITE WORK PLAN
REFERRED FROM:1/4" = 1'-0"AS-101 AS-101
2 PLAN - FUEL CONTROL BUILDING
NOTE: SEE SHEET A-002 AND CIVIL DRAWINGS FOR ADDITIONAL
DIMENSIONS AND DETAILS.
45' - 1" ±
16' - 5 3/4"
:TYP, EXTERIOR
S L O P E
S L O P E
EXISTING WALLS TO REMAIN
PROVIDE NEW STUD WALLS
4' - 6"
E Q
E Q
E Q
13' - 7"
FRP
(AT EXISTING HEIGHT)
EXISTING TO REMAIN
:TYP, 4 FIXTURES
EXISTING TO REMAIN
EXISTING TO REMAIN
S L O P E
S L O P E
1/8" = 1'-0"A-101
1 NEW WORK FLOOR PLAN
03-01 PROVIDE CONCRETE SLAB AND CURB. SLOP SLAB
TO NEW FLOOR DRAINS. SEE STRUCTURAL
DRAWINGS FOR ADDITIONAL INFORMATION.
03-02 PATCH AND REPAIR WHERE CONCRETE SLAB WAS
REMOVED AND PREPARE FOR INSTALLATION OF
NEW SLAB.
07-01 PROVIDE ASPHALT SHINGLE ROOFING TO MATCH
EXISTING COLOR, TEXTURE, AND PROPORTION.
PROVIDE ROOF PENETRATIONS, SILLS, AND
CRICKETS TO ACCOMMODATE WITH ROOFTOP
MECHANICAL EQUIPMENT. ENSURE MINIMUM
POSITIVE DRAINAGE AWAY FROM EQUIPMENT AND
TOWARDS GUTTERS. SEE MECHANICAL DRAWINGS
FOR ADDITIONAL INFORMATION.
07-04 PROVIDE ALUMINUM GUTTER SLOPED TO
DOWNSPOUTS TO MATCH EXISTING GUTTER SIZE
AND FINISH.
07-05 PROVIDE ALUMINUM DOWNSPOUT AND SPLASH
BLOCK.
07-06 PROVIDE ALUMINUM DRIP EDGE TO MATCH
EXISTING PROFILE AND FINISH.
09-01 PROVIDE METAL STUD WALL PARTITION.
09-02 PREPARE SURFACE AND PAINT TO MATCH
EXISTING COLOR.
22-01 PROVIDE CEILING-MOUNTED BOOM-STYLE
CAR-WASH EQUIPMENT. SEE PLUMBING DRAWINGS
FOR ADDITIONAL INFORMATION. CENTER BOOM
INSIDE WASHDOWN SPACE OR PLACE PER
MANUFACTURER RECOMMENDATIONS.
23-03 PROVIDE ALUMINUM RIDGE VENT.
26-05 PROVIDE CEILING-MOUNTED WATER-RESISTANT
LED LIGHTING FIXTURE. SEE ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION.
NATIONAL PARK SERVICE INTERIOR REGION 1 NATIONAL CAPITAL AREA
DESIGN AND PROJECT MANAGEMENT
UNITED STATES
OF
SHEET
DWG. NO.
DATE
DEPARTMENT OF THE INTERIOR
SUB SHEET NUMBERTITLE OF DRAWING
Mark Sheet InitialDateREVISION
DESIGNED
DRAWN
CHECKED
TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
21000 ATLANTIC
EAST POTOMAC MAINTENANCE YARD
REHABILITATION OF THE FUEL SYSTEMS
NATIONAL MALL AND MEMORIAL PARKS (NAMA)
DVA
DVA
JNW
165425
254579
PMIS#
NOT FOR
CONSTRUCTION DULLES, VA 20166
BOULEVARD, SUITE 400
(703) 450 0800 www.alphacorporation.com
08.27.2021
A 101
FLOOR PLANS
REFERRED FROM:1/8" = 1'-0"A-101 A-201
2 NEW WORK REFLECTED CEILING PLAN
REFERRED FROM:1/8" = 1'-0"A-101 A-201
3 ROOF PLAN
0'-0" MATCH EXISTING
19' - 1"±
0'-0" MATCH EXISTING
19' - 1"±
5' - 0" 3' - 0"
1' - 8" 5' - 0"
0'-0" MATCH EXISTING
19' - 1"±
11' - 0" ± 2' - 0"
0'-0" MATCH EXISTING
19' - 1"±
NATIONAL PARK SERVICE INTERIOR REGION 1 NATIONAL CAPITAL AREA
DESIGN AND PROJECT MANAGEMENT
UNITED STATES
OF
SHEET
DWG. NO.
DATE
DEPARTMENT OF THE INTERIOR
SUB SHEET NUMBERTITLE OF DRAWING
Mark Sheet InitialDateREVISION
DESIGNED
DRAWN
CHECKED
TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
21000 ATLANTIC
EAST POTOMAC MAINTENANCE YARD
REHABILITATION OF THE FUEL SYSTEMS
NATIONAL MALL AND MEMORIAL PARKS (NAMA)
DVA
DVA
JNW
165425
254579
PMIS#
NOT FOR
CONSTRUCTION DULLES, VA 20166
BOULEVARD, SUITE 400
(703) 450 0800 www.alphacorporation.com
08.27.2021
A 201
ELEVATIONS
23-02 PROVIDE THRU-WALL PROPELLER FAN. SEE
MECHANICAL DRAWINGS FOR ADDITIONAL
INFORMATION.
23-04 PROVIDE MECHANICAL LOUVER TO MATCH
EXISTING. SEE MECHANICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
23-05 EXISTING THRU-WALL PROPELLER FAN.
23-06 EXISTING ATTIC LOUVER, ±9 SF.
REFERRED FROM:1/8" = 1'-0"A-201 A-101
2 NORTH EXTERIOR ELEVATION
REFERRED FROM:1/8" = 1'-0"A-201 A-101
4 SOUTH EXTERIOR ELEVATION
REFERRED FROM:1/8" = 1'-0"A-201 A-101
1 WEST EXTERIOR ELEVATION
REFERRED FROM:1/8" = 1'-0"A-201 A-101
3 EAST EXTERIOR ELEVATION
10 1/2"
3 1/2"
6"
MIN
PROVIDE ASPHALT
RIDGE SHINGLE
PROVIDE CONTINUOUS
RIDGE VENT
PROVIDE ASPHALT
SHINGLE ROOFING
PROVIDE ROOFING
UNDERLAYMENT
SHEATHING
5/ 8"
1"
MA
X
8"
MI
N
SHEATHING
PROVIDE ASPHALT
SHINGLE ROOFING
PROVIDE SELF-ADHERED
ROOFING UNDERLAYMENT
PROVIDE ALUMINUM FLASHING
PROVIDE GUTTER WITH BRACKETS,
SLOPED TO DOWNSPOUTS.3
M
IN
4" MIN
SHEATHING
PROVIDE ROOFING
UNDERLAYMENT.
PROVIDE ALUMINUM
ROOF EDGE TRIM.
PROVIDE ALUMINUM
FLASHING
PROVIDE ASPHALT
SHINGLES
2" MIN
M
IN
M A T C H
E X
IS
T
IN
G
8" MIN3/4"
EXISTING ROOF DECK
PROVIDE MIN R-38 INSULATION
ABOVE NEW CEILING.
PROVIDE PVC CEILING PANELS
ON EXISTING STRUCTURE.
SEE REFLECTED CEILING PLAN.
PROVIDE PVC PANELS ON
WASHDOWN SIDE OF WALL.
PROVIDE GWB ON REPAIR BAY
SIDE OF WALL.
EXISTING GWB CEILING.
SEE REFLECTED CEILING PLAN.
PROVIDE CONTINUOUS
SEALANT ON BOTH SIDES.
TERMINATE METAL STUD BELOW
EXISTING TRUSSES.
NATIONAL PARK SERVICE INTERIOR REGION 1 NATIONAL CAPITAL AREA
DESIGN AND PROJECT MANAGEMENT
UNITED STATES
OF
SHEET
DWG. NO.
DATE
DEPARTMENT OF THE INTERIOR
SUB SHEET NUMBERTITLE OF DRAWING
Mark Sheet InitialDateREVISION
DESIGNED
DRAWN
CHECKED
TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
21000 ATLANTIC
EAST POTOMAC MAINTENANCE YARD
REHABILITATION OF THE FUEL SYSTEMS
NATIONAL MALL AND MEMORIAL PARKS (NAMA)
DVA
DVA
JNW
165425
254579
PMIS#
NOT FOR
CONSTRUCTION DULLES, VA 20166
BOULEVARD, SUITE 400
(703) 450 0800 www.alphacorporation.com
08.27.2021
A 500
DETAILS
REFERRED FROM:3" = 1'-0"A-500
1 ASPHALT SHINGLE RIDGE DETAIL
REFERRED FROM:3" = 1'-0"A-500
2 GUTTER
REFERRED FROM:3" = 1'-0"A-500
3 DRIP EDGE
REFERRED FROM:1 1/2" = 1'-0"A-500 A-101
4 PARTITION HEAD DETAIL
1. PROVIDE THE FOLLOWING AT ALL LOCATIONS WHERE THE JUNCTION OF THE PARTITION TO UNDERSIDE
OF FLOOR OR ROOF DECK IS CONCEALED TO VIEW (ABOVE CEILINGS THAT ARE INSTALLED WALL TO
WALL).
AT FIRE RATED/SMOKE BARRIER PARTITIONS, CLOSE THE VOID BETWEEN PARTITIONS AND UNDERSIDE
OF FLOOR OR ROOF DECK WITH MINERAL WOOL (SAFING INSULATION) AND FIRE DAM SPRAY OR SPEC
SEAL ELASTOMERIC SPRAY ON EACH SIDE OF THE PARTITION FOR A 1-HR OR 2-HR FIRE-RATING.
USE UL. SYSTEM HW-D-0020 OR HW-D-0043 FOR GYPSUM BOARD PARTITIONS. USE UL. SYSTEM
HW-D-0022 OR HW-D-0088 FOR CMU PARTITION.
AT INTERIOR SIDE OF EXTERIOR WALLS TO BOTTOM OF FLOOR OR ROOF DECK AND AT ALL OTHER
PARTITIONS, CLOSE THE VOID BETWEEN PARTITION AND UNDERSIDE OF DECK WITH MINERAL WOOL
(SAFING INSULATION) AND FIRE DAM SPRAY OR SPEC SEAL ELASTOMERIC ON EACH SIDE OF THE
PARTITION USING SAME UL. SYSTEM (1 HOUR) AS NOTED ABOVE.
2. AT METAL STUD PARTITIONS, PROVIDE 20 GAUGE DOUBLE METAL STUDS AT ALL DOOR OR BORROWED
LITE JAMBS. STUDS ARE TO EXTEND FROM FLOOR TO UNDERSIDE OF FLOOR OR ROOF DECK ABOVE
AND SHALL BE ANCHORED TO EACH END.
3. TYPICAL ALL STUD PARTITION TYPES: PROVIDE CONTINUOUS BLOCKING, REINFORCING SUPPORT, FOR
ALL WALL HUNG ITEMS INCLUDING HANDRAILS, GRAB BARS, MILLWORK.
PARTITION DETAIL NOTES
PROVIDE MAXIMUM 30'-0" OC, LOCATE AT DOOR OR
WINDOW JAMBS WHERE POSSIBLE
MINERAL WOOL INSULATION
ACOUSTICAL SEALANT
AT NON-RATED PARTITIONS:
WRAP ALL SIDES OF ELEC/COMM
BOX WITH BOX PADS
WALL CONTROL JOINT (NR)
(TYPICAL CONDITIONS)
STAGGER LOCATION OF ALL OUTLETS
SHOWN BACK TO BACK ON
ELECTRICAL DRAWINGS
AT RATED PARTITIONS: WRAP ALL
SIDES OF ELECTRICAL BOX WITH
FIRE-RATED PUTTY PAD
STUD PARTITION TO STEEL DECK
(WHERE USG GYPSUM BOARD IS NOT USED)
DO NOT ATTACH GYPSUM
BOARD TO TOP RUNNER
6" HIGH GYPSUM BOARD
STRIP CUT TO FOLLOW
PROFILE OF METAL DECK
MINERAL WOOL INSULATION
FLOOR OR ROOF ASSEMBLY
DEFLECTION TRAK SYSTEM
PLAN AT ALL ELECTRICAL
AND COMMUNICATION BOXES
(TYPICAL CONDITION)
SEE PARTITION TYPES FOR
WALL CONSTRUCTION
METAL CONTROL JOINT
PROVIDE MAXIMUM 30'-0" OC, LOCATE AT DOOR OR
WINDOW JAMBS WHERE POSSIBLE
2 LAYERS 5/8" TYPE X GWB FOR
1-HR FIRE-RATING. 3 LAYERS
FOR 2-HR FIRE-RATING.
WALL CONTROL JOINT
(1 OR 2 HR FIRE-RATING)
(TYPICAL CONDITIONS)
SEE PARTITION TYPES
FOR WALL CONSTRUCTION METAL CONTROL JOINT
5/8" GAP
H O L D
PROVIDE 5/8" ABUSE-RESISTANT
GYPSUM WALLBOARD.
PROVIDE METAL STUD RUNNER
BELOW EXISTING TRUSS
FRAMING.
PROVIDE METAL STUD FRAMING.
SEE STRUCTURAL DRAWINGS FOR
ADDITIONAL INFORMATION.
STUD PARTITION
UL DESIGN: NOT REQUIRED.
PROVIDE CONTINUOUS SEALANT
ON BOTH SIDES.
PROVIDE METAL RUNNER
TRACK. SEE STRUCTURAL
DRAWINGS FOR ADDITIONAL
INFORMATION.
PROVIDE CONTINUOUS SEALANT ON
BOTH SIDES.
PAINT. SEE SPECIFICATION
SECTION 099611 'HIGH
PERFORMANCE COATINGS'.
EXISTING CEILING.
PVC PANEL
WASHDOWN SIDE MAINTENANCE
SIDE
CONCRETE SLAB AND
CURB. SEE STRUCTURAL
DRAWINGS FOR
ADDITIONAL
INFORMATION.
PROVIDE EXPANSION JOINT. SEE STRUCTURAL
DRAWINGS FOR ADDITIONAL INFORMATION.
EXISTING CONCRETE SLAB
NATIONAL PARK SERVICE INTERIOR REGION 1 NATIONAL CAPITAL AREA
DESIGN AND PROJECT MANAGEMENT
UNITED STATES
OF
SHEET
DWG. NO.
DATE
DEPARTMENT OF THE INTERIOR
SUB SHEET NUMBERTITLE OF DRAWING
Mark Sheet InitialDateREVISION
DESIGNED
DRAWN
CHECKED
TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
21000 ATLANTIC
EAST POTOMAC MAINTENANCE YARD
REHABILITATION OF THE FUEL SYSTEMS
NATIONAL MALL AND MEMORIAL PARKS (NAMA)
DVA
DVA
JNW
165425
254579
PMIS#
NOT FOR
CONSTRUCTION DULLES, VA 20166
BOULEVARD, SUITE 400
(703) 450 0800 www.alphacorporation.com
08.27.2021
A 600
PARTITION TYPES
1" = 1'-0"A-600
1 WASHDOWN WALL SECTION
CODES AND STANDARDS
THE FOLLOWING CODES AND STANDARDS, INCLUDING ALL
SPECIFICATIONS REFERENCED WITHIN, APPLY TO THE DESIGN AND
CONSTRUCTION OF THIS PROJECT.
1. GENERAL:
a. INTERNATIONAL BUILDING CODE, 2015
b. INTERNATIONAL EXISTING BUILDING CODE, 2015
c. 2017 DISTRICT OF COLUMBIA BUILDING CODE
d. ASCE 7-10, "MINIMUM DESIGN LOADS FOR BUILDINGS AND
OTHER STRUCTURES"
2. CONCRETE:
a. ACI 301-10, "STANDARD SPECIFICATIONS FOR STRUCTURAL
CONCRETE"
b. ACI 318-10, "BUILDING CODE REQUIREMENTS FOR
STRUCTURAL CONCRETE"
3. MASONRY:
a. ACI 530/ASCE 5/TMS 402-13, "BUILDING CODE REQUIREMENTS
FOR MASONRY STRUCTURES"
b. ACI 530.1/ASCE 6/TMS 602-13, "SPECIFICATION FOR MASONRY
STRUCTURES"
4. COLD-FORMED STEEL FRAMING:
a. AISI, "STANDARD FOR COLD-FORMED STEEL FRAMING-
GENERAL PROVISIONS", 2012 EDITION
b. AISI, "STANDARD FOR COLD-FORMED STEEL FRAMING-WALL
STUD DESIGN", 2007 EDITION WITH SUPPLEMENT 1 (2012)
c. AISI, "STANDARD FOR COLD-FORMED STEEL FRAMING-
HEADER DESIGN", 2007 EDITION (REAFFIRMED 2012)
d. AISI, "STANDARD FOR COLD-FORMED STEEL FRAMING-TRUSS
DESIGN", 2012 EDITION
5. STRUCTURAL WOOD:
a. AWC/NDS, "NATIONAL DESIGN SPECIFICATIONS FOR WOOD
CONSTRUCTION", 2012 EDITION W/ SUPPLEMENT
MATERIALS
ITEM
1. SOIL:
2. CAST-IN-PLACE CONC:
a. FOUNDATIONS
b. PIERS
c. TYPICAL FLOORS
d. EQUIPMENT PADS
3. CONC & MASONRY REINF:
a. BARS
b. WWF
4. MASONRY:
a. CMU ASSEMBLY
b. CMU
c. MORTAR
d. GROUT
5. STRUCTURAL STEEL:
a. "W" SHAPES
b. HSS, SQ OR RECT
c. HSS, ROUND
d. OTHER SHAPES/
PLATES
e. HIGH STRENGTH
BOLTS
f. ANCHOR RODS
g. WELDING ELECTRODES
6. METAL DECK:
a. ROOF DECK
NOTES
SEE FOUNDATION & EARTHWORK NOTES
NLWT
NLWT, AE (SEVERE EXPOSURE)
NLWT, (SEVERE EXPOSURE)
NLWT, AE (SEVERE EXPOSURE)
ASTM A615, GRADE 60
ASTM A185
ASTM C90, NLWT
ASTM C270, TYPE S
ASTM C476
ASTM A992, GRADE 50
ASTM A500, GRADE B
ASTM A500, GRADE B
ASTM A36
ASTM A325 OR A490
ASTM 1554 GRADE 55
E70XX
ASTM A792 GRADE 50,
AZ50 COATING
MIN STRENGTH
F'c=5,000 PSI F'c=5,000 PSI F'c=5,000 PSI F'c=5,000 PSI
Fy=60,000 PSI Fy=65,000 PSI
F'm=1,900 PSI F'c=1,700 PSI F'c=1,800 PSI F'c=2,000 PSI
Fy=50,000 PSI Fy=46,000 PSI Fy=42,000 PSI Fy=36,000 PSI
Fy=55,000 PSI
Fy=55,000 PSI
DESIGN LOADS
1. DEAD LOAD
2. FLOOR LIVE LOAD
3. ROOF LIVE LOAD
4. SNOW LOAD
5. WIND LOADS:
6. SEISMIC DESIGN
SELF WEIGHT + SUPERIMPOSED
RISK CATEGORY
GROUND SNOW LOAD Pg
IMPORTANCE FACTOR I
EXPOSURE FACTOR Ce TEMPERATURE FACTOR Ct
RISK CATEGORY
ULTIMATE WIND SPEED
WIND IMPORTANCE FACTOR
EXPOSURE
*INTERNAL PRESSURE COEF.
*COMPONENTS AND CLADDING
RISK CATEGORY
SPECTRAL RESPONSE COEF.
SEISMIC IMPORTANCE FACTOR
PERIOD ACCELERATION
SITE CLASS
*RESISTING SYSTEM
*ANALYSIS PROCEDURE
*RESPONSE MODIFICATION FACTOR
*SEISMIC DESIGN CATEGORY
*SEISMIC RESPONSE COEFFICIENT
*BASE SHEAR
ACTUAL
N/A
30 PSF
II
25 PSF
1.0 1.0 1.2
II
115 MPH
1.0 C
II
Sds = 0.126 Sd1 = 0.082 1.0 Ss = 0.0118 S1 = 0.051
D (ASSUMED)
GENERAL NOTES
1. SEE CIVIL DOCUMENTS FOR REFERENCED DATUM AND ELEVATIONS FOR
ALL EXTERIOR STRUCTURES.
2. ALL DETAILS, SECTIONS, AND NOTES SHOWN ON THE DRAWINGS ARE
INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR SITUATIONS, UNO.
3. DO NOT SCALE DRAWINGS.
4. NO CHANGE IN SIZE, DIMENSION OR POSITION OF STRUCTURAL ELEMENTS
SHALL BE MADE WITHOUT THE APPROVAL OF THE COR.
5. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE
STARTING CONSTRUCTION AND/OR SUBMITTING SHOP DRAWINGS. ANY
DISCREPANCIES SHALL BE REPORTED TO THE COR.
6. REFER TO ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, PLUMBING,
AND FIRE PROTECTION DRAWINGS FOR DIMENSIONS AND LOCATIONS OF
OPENINGS, INSERTS, DEPRESSIONS, EQUIPMENT PADS, DRIPS, REVEALS,
FINISHES, AND OTHER SUCH PROJECT REQUIREMENTS NOT SHOWN ON
STRUCTURAL DRAWINGS.
7. SUBMIT DIMENSIONED COORDINATED SHOP DRAWINGS SHOWING THE
LOCATIONS OF ALL SLEEVES AND OPENINGS REQUIRED BY ALL TRADES
THROUGH STRUCTURAL ELEMENTS. ANY ADDITIONAL OPENINGS NOT
SHOWN ON SHOP DRAWINGS WILL REQUIRE WRITTEN APPROVAL OF THE
COR.
8. TAKE ALL MEASURES NECESSARY TO PROTECT EXISTING AND NEW
UTILITIES AND BUILDINGS AND ASSUME FULL RESPONSIBILITY FOR ANY
DAMAGE DURING CONSTRUCTION. RESTORATION OF DAMAGED AREAS
SHALL BE TO THE SATISFACTION OF THE OWNER, AT NO COST TO THE
OWNER.
9. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR
DETAILED INFORMATION REGARDING FINISHES, FIREPROOFING,
WATERPROOFING, LOCATIONS OF MASONRY AND DRYWALL NON-LOAD
BEARING PARTITIONS, EXTERIOR FACE OF BUILDING, ETC.
10. DO NOT REPRODUCE ANY PORTION OF THE STRUCTURAL CONTRACT
DRAWINGS FOR RESUBMITTAL AS SHOP DRAWINGS. SHOP DRAWINGS
PRODUCED IN SUCH A MANNER WILL BE REJECTED AND RETURNED.
11. CONTRACTOR IS TO BE RESPONSIBLE FOR ALL SHORING, SCAFFOLDING,
AND OTHER TEMPORARY STRUCTURES USED AND ERECTED DURING
CONSTRUCTION. CONTRACTOR IS ALSO RESPONSIBLE FOR INSURING
IMPOSED LOADS DO NOT EXCEED THE EXISTING STRUCTURE'S CAPACITY.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGE RESULTING FROM
OVERLOADING THE EXISTING STRUCTURE. DRAWINGS, SIGNED AND
SEALED BY A STRUCTURAL ENGINEER, SHALL BE SUBMITTED TO THE COR
FOR ALL SHORING AND SCAFFOLDING AND UNDERPINNING.
12. THE EXISTING BUILDING VERTICAL AND HORIZONTAL LOADS ARE NOT
BEING AFFECTED ENOUGH TO REQUIRE THE BUILDING STRUCTURE TO BE
UPDATED TO THE NEW CODE REQUIREMENTS PER THE EXISTING BUILDING
CODE. UPDATING THE EXISTING BUILDING IS NOT INCLUDED IN THIS WORK.
CAST-IN-PLACE CONCRETE
1. CONC COVER OVER ALL REINF SHALL BE AS FOLLOWS, UNO:
a. SURFACES CAST AGAINST & PERMANENTLY EXPOSED TO EARTH OR
WEATHER = 3"
b. SURFACES EXPOSED TO EARTH OR WEATHER AFTER PLACEMENT:
1) #5 & SMALLER BARS = 1 1/2"
2) #6 & LARGER BARS = 2"
c. SURFACES NOT EXPOSED TO EARTH OR WEATHER:
1) SLABS AND WALLS = 3/4"
2) BEAMS, COLUMNS, & SIMILAR ELEMENTS (COVER TO
STIRRUPS & TIES) = 1 1/2"
2. DOWELS SHALL MATCH AND BE LAP SPLICED WITH THE MAIN REINF, UNO.
3. VAPOR BARRIER TO BE 10 MIL CLASS A. GRANULAR FILL TO BE #57 STONE.
GRANULAR FILL TO BE 4" THICK FOR INTERIOR BUILDING SLAB AND 6" THICK
FOR EXTERIOR SLABS.
4. PROVIDE ADDITIONAL REINFORCEMENT AROUND ALL OPENINGS AS INDICATED.
ALL CONC SHALL BE REINFORCED AS INDICATED. WHERE REINFORCING IS NOT
INDICATED PROVIDE THE FOLLOWING:
a. SLABS-ON-GRADE - #6 AT 12" EW, EF
5. FIELD BENDING OF REINF PARTIALLY EMBEDDED IN CONC IS NOT PERMITTED
UNLESS INDICATED ON THE DWGS OR APPROVED IN WRITING BY THE COR.
6. SPLICE REINF BARS PER ACI 318, CLASS B, TENSION LAP SPLICES, UNO.
7. WWF SHALL BE LAP SPLICED PER ACI 318 AND TIED SECURELY.
8. WELDING OF REINF IS NOT PERMITTED UNLESS INDICATED OR APPROVED IN
WRITING BY THE COR.
9. ALLOW A MINIMUM OF 12 HOURS BETWEEN COMPLETING PLACEMENT OF
CONCRETE FOR WALLS, COLUMNS & PIERS AND BEGINNING PLACEMENT OF
ADJACENT CONCRETE.
10. ALL CONSTRUCTION JOINTS SHALL BE WIRE BRUSHED, CLEANED, &
MOISTENED WITH A CEMENT SLURRY SCRUBBED INTO THE JOINT IMMEDIATELY
PRIOR TO PLACING NEW CONCRETE.
11. PROVIDE A WATERSTOP IN ALL CONSTRUCTION JOINTS BELOW GRADE AND
WHERE INDICATED.
12. PLACE NORMAL WEIGHT SLABS-ON-GRADE IN ALTERNATING STRIP SECTIONS
HAVING A MAXIMUM WIDTH OF 50 FEET. LENGTH OF STRIP SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR AND SHALL REPRESENT CONCRETE
OPERATIONS THAT CAN BE PLACED WITHIN THE "WINDOW OF FINISHABILITY"
AS DEFINED BY ACI COMMITTEE 302. ALLOW ADEQUATE TIME FOR FINISHING
OPERATIONS TO OCCUR BEFORE PLACEMENT OF ADJACENT SECTIONS.
13. CRACK CONTROL JOINTS SHOWN ON PLAN ARE SUGGESTED LOCATIONS.
ADDITIONAL CONTROL JOINTS TO BE PROVIDED PER RECOMMENDATIONS
FOUND IN ACI 224.3R-95, 1995 EDITION AND AS FOLLOWS:
a. SLAB-ON-GRADE:
1) FOR SLABS LESS THAN OR EQUAL TO 6" THICK, MAX SPACING
SHALL BE 36 TIMES THE SLAB THICKNESS.
2) FOR SLABS GREATER THAN 6" THICK, MAX SPACING SHALL BE 24
TIMES THE SLAB THICKNESS.
b. WALLS:
1) FOR WALLS LESS THAN OR EQUAL TO 7'-0" HIGH, MAX SPACING
SHALL BE THREE TIMES THE WALL HEIGHT.
2) FOR WALLS GREATER THAN 7'-0" BUT LESS THAN 13'-0" HIGH, MAX
SPACING SHALL BE TWO TIMES THE WALL HEIGHT.
3) FOR WALLS GREATER THAN 13'-0" HIGH, MAX SPACING SHALL
EQUAL THE WALL HEIGHT.
ABBREVIATIONS
ACI
AE
AISC
ARCH
ASCE
ASTM
AWS
CMU
CONC
CONT
COR
DIA
DWG
EF
ELEV
EMBED
EQ
EW
EX
GALV
AMERICAN CONCRETE INSTITUTE
AIR-ENTRAINED
AMERICAN INSTITUTE
OF STEEL CONSTRUCTION
ARCHITECTURAL
AMERICAN SOCIETY
OF CIVIL ENGINEERS
AMERICAN SOCIETY
FOR TESTING & MATERIALS
AMERICAN WELDING SOCIETY
CONCRETE MASONRY UNIT
CONCRETE
CONTINUOUS
CONTRACT OWNER'S REPRESENTATIVE
DIAMETER
DRAWING
EACH FACE
ELEVATION
EMBEDMENT
EQUAL
EACH WAY
EXISTING
GALVANIZE
LF
MAX
MANUF
MECH
MIN
MPH
NLWT
OC
PSF
PSI
PSL
REINF
SOG
STRUCT
TMS
TYP
UNO
VIF
WWF
LINEAR FEET
MAXIMUM
MANUFACTURER
MECHANICAL
MINIMUM
MILES PER HOUR
NORMAL WEIGHT
ON CENTER
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PARALLEL STRAND LUMBER
REINFORCING
SLAB-ON-GRADE
STRUCTURAL
THE MASONRY SOCIETY
TYPICAL
UNLESS NOTED OTHERWISE
VERIFY IN FIELD
WELDED WIRE FABRIC
COLD FORMED METAL FRAMING
1. LATERAL LOAD DEFLECTIONS FOR STEEL STUDS SHALL NOT EXCEED L/360.
2. "PAF" INDICATES POWDER ACTUATED FASTENER WITH DIAMETER = 0.145 INCH
AND SUFFICIENT LENGTH TO PENETRATE THE STEEL BASE MATERIAL.
MAINTAIN 1/2 INCH MINIMUM EDGE DISTANCE.
3. "SCREW" INDICATES #10-16 SELF-DRILLING SCREW. DRILLING MUST BE
COMPLETED BEFORE THE THREADS ENGAGE THE MATERIAL. PENETRATION
THROUGH JOINED MATERIALS SHALL NOT BE LESS THAN THREE EXPOSED
THREADS.
WOOD
1. WHERE NOTED OR EXPOSED TO WEATHER,
WOOD TO BE PRESSURE TREATED IN
ACCORDANCE WITH AWPA (AMERICAN
WOOD PRESERVERS ASSOCIATION),
STANDARD UI.
a. POSTS - AWPA USE CATEGORY
UC4A GROUND CONTACT
b. SILL PLATES, RAFTERS, AND DOOR
FRAMING NOT IN CONTACT WITH EARTH-
AWPA USE CATEGORY UC3B
c. PSL COLUMNS - AWPA USE
CATEGORY UC4B
2. ALL TREATED LUMBER TO BE MARKED
"KDAT" (KILN DRIED AFTER TREATMENT).
3. CHECK LUMBER FOR EXCESSIVE WANE,
KNOTS, CURVATURE, CRACKS, AND OTHER
DEFECTS WHICH COULD AFFECT
APPEARANCE. CULL LUMBER AS
NECESSARY.
4. WHERE PRESSURE TREATED LUMBER IS
TO BE PAINTED, MAKE SURE WOOD IS
DRIED PROPERLY AND FOLLOW PAINT
MANUFACTURERS RECOMMENDATIONS
FOR PAINTING TREATED LUMBER.
5. ALL FASTENERS TO BE HOT DIP
GALVANIZED UNO. FINISH TO BE
COMPATIBLE WITH PRESSURE
TREATMENT.
6. ALL NAILS ARE AS FOLLOW: 16D-0.135"
DIAMETER-3.25" LONG; 12D-0.135"
DIAMETER-3" LONG. NAILS TO BE HOT DIP
GALVANIZED, UNO.
7. FRAMING LUMBER TO BE SOUTHERN
YELLOW PINE SYP #2, UNO.
8. ALL TREATED LUMBER TO BE SYP #2, UNO.
9. HANGERS TO BE SIMPSON STRONGTIE OR
APPROVED EQUAL. ALL HANGERS TO BE
HOT DIP GALVANIZED, UNO.
DELEGATED DESIGN
1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE DELEGATED
DESIGN FOR ITEMS INDICATED ON THE DRAWINGS AND/OR
SPECIFICATIONS.
2. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW IN
ACCORDANCE WITH SPEC SECTION 01 33 00 SUBMITTALS.
3. THE CONTRACTOR SHALL SUBMIT CALCULATIONS SEALED BY A
PROFESSIONAL ENGINEER REGISTERED IN THE DISTRICT OF
COLUMBIA FOR REVIEW BY THE COR.
4. CONSTRUCTION SHALL NOT PROCEED UNTIL THE DESIGN HAS BEEN
ACCEPTED THE COR.
5. DELEGATED DESIGNS INCLUDED UNDER THIS CONTRACT INCLUDE,
BUT ARE NOT LIMITED TO THE DESIGN OF:
A. PRE-ENGINEERED CANOPY-STRUCTURE AND FOUNDATION
B. PRE-ENGINEERED FUEL CONTROL BUILDING-STRUCTURE
AND CONNECTION TO FOUNDATION
STRUCTURAL STEEL
1. ALL CONNECTIONS TO BE FULLY DESIGNED AND DETAILED BY THE
MANUFACTURER.
2. BOLTED CONNECTIONS SHALL USE A MINIMUM OF TWO 3/4"
DIAMETER A325 BOLTS.
3. TIGHTEN ALL BOLTS TO THE "SNUG TIGHT" CONDITION, EXCEPT
WHERE NOTED ON THE DRAWINGS TO BE SLIP CRITICAL (SC).
4. THE MINIMUM FILLET WELD SHALL BE PER AISC SPECIFICATIONS,
BUT NOT LESS THAN 1/4", UNO.
5. AFTER FABRICATION, STEEL SHALL BE CLEANED OF ALL RUST,
LOOSE MILL SCALE AND OTHER FOREIGN MATERIALS.
6. ALL STRUCTURAL STEEL AND HARDWARE TO BE HOT DIP
GALVANIZED.
7. DO NOT FIELD CUT STRUCTURAL STEEL MEMBERS WITHOUT THE
WRITTEN APPROVAL OF THE MANUFACTURER.
8. DO NOT USE THERMAL CUTTING DURING ERECTION UNLESS
APPROVED BY MANUFACTURER. IF APPROVED, FINISH THERMALLY
CUT SECTIONS WITHIN SMOOTHNESS LIMITS IN AWS D1.1.
9. DO NOT SPLICE STEEL MEMBERS.
10. PROVIDE AND BE RESPONSIBLE FOR ALL TEMPORARY BRACING
AND ERECTION PROCEDURES. TEMPORARY BRACING SHALL
REMAIN IN PLACE UNTIL ALL STRUCTURAL MEMBERS ARE
PROPERLY ALIGNED AND CONNECTED.
11. SHOP AND FIELD TESTING OF WELDS AND BOLTS SHALL BE AS
CONDUCTED BY THE CONTRACTOR'S TESTING AGENCY AS
FOLLOWS:
a. ALL WELDS SHALL BE VISUALLY INSPECTED; MEASURE
25%, AT RANDOM.
b. USING MAGNETIC PARTICLE CHECK THE FINAL PASS OF
FILLET WELDS:
1) 25%, AT RANDOM, OF BEAM & GIRDER SHEAR
CONNECTIONS
2) 100% OF FLANGE CONTINUITY PLATES
c. ULTRASONICALLY TEST:
1) ALL COMPLETE PENETRATION WELDS
2) CHECK FOR DELAMINATIONS IN COLUMN FLANGES AT
ALL MOMENT CONNECTIONS WHERE EITHER THE BEAM
OR COLUMN FLANGE IS GREATER THAN 1-1/2" THICK
3) DELAMINATIONS IN THE FLANGES OF PLATE GIRDERS
THAT ARE THICKER THAN 2", ONLY THE MIDDLE THIRD
OF THE SPAN NEED BE TESTED.
d. RADIOGRAPHICALLY TEST 5%, AT RANDOM, OF COMPLETE
PENETRATION WELDS.
e. CHECK ALL BOLTED CONNECTIONS AS OUTLINED IN AISC
SPECIFICATIONS.
METAL DECK
1. THE SIZE AND TYPE OF DECK SHOWN BELOW IS BASED ON
UNSHORED CONSTRUCTION AND INDIVIDUAL SHEETS OF DECK
CONTINUOUS FOR AT LEAST 3 SPANS. WHERE THE DECK WILL BE
INSTALLED FOR 1 AND 2 SPAN CONDITIONS ADJUST THE THICKNESS,
PROVIDE SHORING, ETC. SO THAT THE DECK WILL SUPPORT THE
SAME LOAD AS A 3 SPAN CONDITION.
2. DECK SECTION PROPERTIES SHALL BE COMPUTED IN ACCORDANCE
WITH AISI "SPECIFICATION FOR THE DESIGN OF COLD FORMED
STEEL STRUCTURAL MEMBERS" AND SHALL BE CERTIFIED BY THE
STEEL DECK INSTITUTE (SDI). PROVIDE STEEL DECK WITH THE
FOLLOWING PROPERTIES:
a. ROOF DECK: 3" DEEP X 16" WDE STEEL PANELS
1) PANEL FINISH: POLYESTER BAKE ON FINISH OVER AN
EPOXY PRIMER
3. INSTALL DECK IN ACCORDANCE WITH SDI SPECIFICATIONS,
FACTORY MUTUAL STANDARDS AND AS FOLLOWS:
a. ROOF DECK: INSTALL PER SHOP DRAWINGS PROVIDED BY
MANUFACTURER.
4. PROVIDE, AS REQUIRED, ALL RIDGE AND VALLEY PLATES, COLUMN
COLSURES, CANT STRIPS, SUMP PLATES AND PANS.
5. PROVIDE SUPPLEMENTAL FRAMING AT OPENINGS AS REQUIRED
FOR SUPPORT OF THE METAL DECK. ALL OPENINGS SHALL BE
COORDINATED WITH ARCHITECTURAL AND MEP DRAWINGS.
6. LOCATE HANGERS FROM DECKING SUCH THAT THE CONCENTRATED
LOAD AT ANY ONE HANGER DOES NOT EXCEED 50 POUNDS AND AN
AVERAGE UNIFORM LOAD OF MORE THAN 10 PSF.
FOUNDATIONS & EARTHWORK
1. ALL SOIL AND ROCK SUPPORTED FOUNDATIONS SHALL BEAR ON
UNDISTURBED, NATURAL SUBGRADE, COMPACTED CONTROLLED
FILL, FREE OF ORGANIC MATERIAL AND UNSUITABLE SOIL.
2. THE MINIMUM ALLOWABLE BEARING CAPACITY OF FOUNDATION
SUBGRADES SHALL BE AS FOLLOWS:
a. FOUNDATIONS, BUILDINGS, AND SLABS - 1,500 PSF
3. AFTER THE EXCAVATED AREAS ARE CLEANED OF LOOSE MATERIAL
AND PRIOR TO PLACING CONCRETE, THE SUBGRADE FOR ALL
FOUNDATIONS AND SLABS SHALL BE INSPECTED AND APPROVED BY
THE CONTRACTOR'S GEOTECHNICAL ENGINEER.
*WIND AND SEISMIC
CRITERIA FOR THE
PRE-ENGINEERED
BUILDING AND FUEL
CANOPY ARE TO BE
DETERMINED BY
THE ENGINEERS
RESPONSIBLE FOR
THEIR DESIGN. SEE
"DELEGATED
DESIGN" NOTES FOR
MORE INFO.
FOUNDATIONS & EARTHWORK CONTINUED
4. CONCRETE MUST BE PLACED THE SAME DAY THE SUBGRADE IS INSPECTED.
IF THE SURFACE IS DISTURBED BEFORE CONCRETE IS PLACED, THE
SUBGRADE SHALL BE RE-INSPECTED BY THE CONTRACTOR'S GEOTECHNICAL
ENGINEER AT THE CONTRACTOR'S EXPENSE.
5. PREVENT WATER, FROST, OR ICE FROM COLLECTING ON OR PENETRATING
ANY FOUNDATION OR SLAB SUBGRADE. DO NOT PLACE CONCRETE INTO OR
AGAINST SUBGRADES CONTAINING FREE WATER, FROST, OR ICE. SHOULD
WATER, FROST, OR ICE ENTER A SUBGRADE AFTER IT HAS BEEN ACCEPTED
BY THE CONTRACTOR'S GEOTECHNICAL ENGINEER, THE SUBGRADE SHALL BE
CLEANED AND RE-INSPECTED.
6. DO NOT BACKFILL AGAINST BASEMENT OR RETAINING WALLS UNTIL THE
SLABS THAT RESIST THE LATERAL LOADS HAVE ATTAINED 75% OF THE
DESIGN STRENGTH, UNLESS ADEQUATE TEMPORARY BRACING IS PROVIDED.
7. WHEN FILLING AGAINST OPPOSITE SIDES OF A WALL OR STRUCTURE,
BACKFILL IN LIFTS SUCH THAT THE DIFFERENCE IN FILL ELEVATION ON
OPPOSITE SIDES DOES NOT EXCEED 12".
8. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE DESIGN,
INSTALLATION, AND PERFORMANCE OF ALL DEWATERING, EARTH RETENTION
SYSTEMS, AND UNDERPINNING OF EXISTING STRUCTURES AND UTILITIES.
NATIONAL PARK SERVICE - INTERIOR REGION 1 - NATIONAL CAPITAL AREA
DESIGN AND PROJECT MANAGEMENT
UNITED STATES
OF
SHEET
DWG. NO.
DATE
DEPARTMENT OF THE INTERIOR
SUB SHEET NUMBERTITLE OF DRAWING
Mark Sheet InitialDateREVISION
DESIGNED
DRAWN
CHECKED
TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
2211000000 AATTLLAANNTTIICC
EAST POTOMAC MAINTENANCE YARD
REHABILITATION OF THE FUEL SYSTEMS
NATIONAL MALL AND MEMORIAL PARKS (NAMA)
TWW
SEP
APU
165425
254579
PMIS#
DULLES, VA 20166
BOULEVARD, SUITE 400
(703) 450-0800 www.alphacorporation.com
08.27.2021
S-01
GENERAL NOTES
EX 13'X13' OVERHEAD DOOR EX 10'X13' OVERHEAD DOOR
EX 13'X13' OVERHEAD DOOR EX 10'X13' OVERHEAD DOOR
EX 8" CMU, TYP UNO
EX 12" CMU
EX 12" CMU
EX 12" CMU
EX BOLLARDS
DEMOLISH EX STEEL COLUMNS
DEMO EX PIT
DEMO EX PIT
DEMO EX LIFT
DEMO EX DRAIN
EXTENT OF CONC DEMO
17' - 0 1/2"
EX CONC SLAB TO
BE DEMOLISHED
EX CONC SLAB TO
BE LEFT IN PLACE
EX STEP IN CONCRETE SLAB
NATIONAL PARK SERVICE - INTERIOR REGION 1 - NATIONAL CAPITAL AREA
DESIGN AND PROJECT MANAGEMENT
UNITED STATES
OF
SHEET
DWG. NO.
DATE
DEPARTMENT OF THE INTERIOR
SUB SHEET NUMBERTITLE OF DRAWING
Mark Sheet InitialDateREVISION
DESIGNED
DRAWN
CHECKED
TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
21000 ATLANTIC
EAST POTOMAC MAINTENANCE YARD
REHABILITATION OF THE FUEL SYSTEMS
NATIONAL MALL AND MEMORIAL PARKS (NAMA)
TWW
SEP
APU
165425
254579
PMIS#
DULLES, VA 20166
BOULEVARD, SUITE 400
(703) 450-0800 www.alphacorporation.com
08.27.2021
S-02
STRUCTURAL DEMO PLAN
3/8" = 1'-0"S-02
1 SERVICE BAY DEMOLITION PLAN
0' 4' 8'4'
3/8" = 1'-0" SCALE OF FEET
NOTES:
1. ALL ITEMS TO BE DEMOLISHED ARE TO BE REMOVED AND DISPOSED
OF IN ACCORDANCE WITH ALL DISTRICT OF COLUMBIA STANDARDS
AND REQUIREMENTS.
2. REFER TO OTHER DISCIPLINES FOR EQUIPMENT AND PIPING.
3. ANY DAMAGES TO THE BUILDING CAUSED BY DEMOLITION OF
SPECIFIC ITEMS SHALL BE REPAIRED AT NO COST TO THE OWNER
AND TO THE APPROVAL OF THE OWNER.
4. SAWCUT CONCRETE TO PROVIDE A SMOOTH, CLEAN CUT.
CONTRACTOR SHALL TAKE CARE NOT TO DAMAGE THE EXISTING
BUILDING DURING DEMOLITION.
4" WIDE POLYDRAIN, TOP
OF DRAIN ELEV = -0'-2"
CONC SLAB TO SLOPE
TO DRAIN
CONC SLAB TO SLOPE
TO DRAIN
6" LIGHT GAUGE WALL,
SEE ARCH DWGS FOR
FINISHES. WALL TO SIT
ON CONC CURB WITH A
MINIMUM HEIGHT OF 6".
EX 13'X13' OVERHEAD DOOR
EX 10'X13' OVERHEAD DOOR
EX 13'X13' OVERHEAD DOOR
EX 10'X13' OVERHEAD DOOR
EX 8" CMU, TYP UNO
EX 12" CMU
EX 12" CMU
EX 12" CMU
EXTENTS OF NEW
CONC SLAB AND
EXPANSION JOINT
C S-05
B S-05
INSTALL ISOLATION JOINT
BETWEEN EX MASONRY
AND NEW CONC SLAB, TYP
CONC SLAB ELEV = 0'-0"
(MATCH EXISTING)
CONC SLAB ELEV = 0'-0"
(MATCH EXISTING)
A S-05
16' - 5 3/4" 0' - 6 3/4"
NEW 8" CONC SLAB WITH
#6 BARS AT 12" OC EW
/2
/2
NEW
EXISTING
NATIONAL PARK SERVICE - INTERIOR REGION 1 - NATIONAL CAPITAL AREA
DESIGN AND PROJECT MANAGEMENT
UNITED STATES
OF
SHEET
DWG. NO.
DATE
DEPARTMENT OF THE INTERIOR
SUB SHEET NUMBERTITLE OF DRAWING
Mark Sheet InitialDateREVISION
DESIGNED
DRAWN
CHECKED
TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
21000 ATLANTIC
EAST POTOMAC MAINTENANCE YARD
REHABILITATION OF THE FUEL SYSTEMS
NATIONAL MALL AND MEMORIAL PARKS (NAMA)
TWW
SEP
APU
165425
254579
PMIS#
DULLES, VA 20166
BOULEVARD, SUITE 400
(703) 450-0800 www.alphacorporation.com
08.27.2021
S-03
STRUCTURAL FLOOR PLAN
3/8" = 1'-0"S-03
1 SERVICE BAY FLOOR PLAN
0' 4' 8'4'
3/8" = 1'-0" SCALE OF FEET
NOTES:
1. INFILL PIT AREAS WITH #57 STONE. CONSOLIDATE STONE PRIOR TO
INSTALLING VAPOR BARRIER.
2. INSTALL CHAIRS IN NEW SLAB TO MAINTAIN PROPER ELEVATION OF
REINFORCING.
EX FRAMING
NEW LIGHT GAUGE WALL
BELOW. WALL TO STOP AT
BOTTOM CHORD OF TRUSSES.EX 8" CMU, TYP UNO
EX 12" CMU
EX 12" CMU
EX 12" CMU
EX 13'X13' OVERHEAD DOOR
EX 10'X13' OVERHEAD DOOR
EX 13'X13' OVERHEAD DOOR
EX 10'X13' OVERHEAD DOOR
SEE TYP DETAIL 7 ON S-06 FOR
CONNECTION AT CEILING.
INSTALL AT EVERY OTHER STUD.
EFFLORESCENCE NOTED ABOVE LINTEL.
CONTRACTOR TO INVESTIGATE TO CONFIRM
MOISTURE IS NOT TRAPPED IN THE MASONRY
ABOVE THE OPENING. CONTRACTOR TO
CLEAN AND PAINT EXISTING LINTEL. IF IT
APPEARS THAT WATER IS BEING TRAPPED IN
THE MASONRY, CONTRACTOR SHALL
CONTACT COR FOR DIRECTION.
CONTRACTOR TO CLEAN
AND PAINT EX LINTEL.
REPOINT CRACKS IN
MORTAR JOINTS, 60 LF
REPOINT CRACKS IN
MORTAR JOINTS, 60 LF
REPOINT CRACKS IN
MORTAR JOINTS, 60 LF
REPOINT CRACKS IN
MORTAR JOINTS, 60 LF
NEW 4X10 BEAMS, SYP #2, TO
SUPPORT EQUIPMENT. INSTALL
ABOVE CEILING ELEVATION4'
0"
NEW
EXISTING
NATIONAL PARK SERVICE - INTERIOR REGION 1 - NATIONAL CAPITAL AREA
DESIGN AND PROJECT MANAGEMENT
UNITED STATES
OF
SHEET
DWG. NO.
DATE
DEPARTMENT OF THE INTERIOR
SUB SHEET NUMBERTITLE OF DRAWING
Mark Sheet InitialDateREVISION
DESIGNED
DRAWN
CHECKED
TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
21000 ATLANTIC
EAST POTOMAC MAINTENANCE YARD
REHABILITATION OF THE FUEL SYSTEMS
NATIONAL MALL AND MEMORIAL PARKS (NAMA)
TWW
SEP
APU
165425
254579
PMIS#
DULLES, VA 20166
BOULEVARD, SUITE 400
(703) 450-0800 www.alphacorporation.com
08.27.2021
S-04
CEILING FRAMING
3/8" = 1'-0"S-04
1 CEILING FRAMING
0' 4' 8'4'
3/8" = 1'-0" SCALE OF FEET
0'
8"
0' - 4" 0' - 9"
SEE GENERAL NOTES
FOR GRANULAR FILL AND
VAPOR BARRIER
INFORMATION. FOR
SUBGRADE COMPACTION
SEE SPECIFICATIONS
AND NOTES.
CONC POLYMER DRAIN,
SEE PLAN FOR
LOCATION. POLYDRAIN
OR APPROVED EQUAL.
#6 BARS AT
12" OC, EW
TOP OF
DRAIN = -0'-2"
SLAB SLOPES TO DRAIN
NEW 8" CONC SLAB SLOPES
TO DRAIN, SEE PLAN
MATCH EX ELEV
EX CONC SLAB
EX GARAGE DOOR
AND WALL BEYOND
ISOLATION JOINT,
SEE TYP DETAIL
EX MASONRY
EX MASONRY LINTEL
M
IN
0'
8"
ELEVATION OF
SLAB VARIES AS
IT SLOPES TO THE
DRAIN, SEE PLAN.
1/2" ISOLATION JOINT
600S137-43 P AT 16"
OC LIGHT GAUGE
WALL, SEE PLAN
FOR LOCATION.
INSTALL BRACING
AT 48" OC.
EX SLAB
#6 AT 12" OC EW
#4 BARS AT 12" OC
SEE TYPICAL DETAIL AND
NOTES FOR GRANULAR
FILL AND VAPOR BARRIER
INFORMATION. FOR
SUBGRADE COMPACTION
SEE SPECIFICATIONS
AND NOTES.
SEE ARCH DWGS
FOR FINISHES
(2) #4 BARS
CONTINUOUS
TOP OF SLAB
VARIES
TOP OF CURB = 0'-6"
12" MIN
2' -0
" M
IN1'
0"
6" MIN COMPACTED
GRANULAR FILL
SUBGRADE
#6 BARS AT 12" OC EW,
TOP AND BOTTOM
FUEL STORAGE TANKS -
SEE CIVIL DWGS
NOTE: SEE CIVIL DWGS FOR PAD LOCATION.
SEE CIVIL DWGS
FOR LAYOUT PLAN
SEE CIVIL FOR
ELEVATION
TOP OF PAD, SEE CIVIL DWGS
SEE CIVIL DWGS FOR
CONC PAVEMENT
2" CHAMFER
ISOLATION JOINT, SEE TYP DETAIL
GRADE, SEE CIVIL
12" MIN
2' -0
" M
IN1'
0"
6" MIN
COMPACTED
GRANULAR FILL
SUBGRADE
#6 BARS AT 12"
OC EW, TOP
AND BOTTOM
PRE-ENGINEERED FUEL
CONTROL BUILDING
SEE CIVIL DWGS FOR
LOCATION OF FUEL
CONTROL BUILDING.
BUILDING ALIGNED WITH EDGE
OF CONCRETE PAD TO ALLOW
FOR WATER RUN OFF
CONCRETE SIDEWALK OR
PAVEMENT PER CIVIL DWGS
ISOLATION JOINT,
SEE TYP DETAIL
2" CHAMFER
2" G
AP
EX TRUSS BEYOND,
WEB CONFIGURATION
MAY VARY
BACK SLIGHTLY AROUND STUDS
1/2" MIN TO 1" MAX GAP IN DEFLECTION
TRACK. CUT CEILING GYPSUM.
FLAT STRAP WITHIN 12" OF
DEFLECTION TRACK, SCREW AT
EACH STUD WITH #10 SCREWS,
BOTH NEAR AND FAR SIDES
16" STUD SPACING
ADDED STUDS AT BEARING
LOCATION. DO NOT FASTEN
TO EX ROOF TRUSSES.
(6) #8 WOOD SCREWS
EACH 2" LONG THROUGH
WEB OF EACH METAL STUD
INTO 4X10 EQUIPMENT
SUPPORT BEAM
NEW 4X4 BETWEEN BEARING STUDS.
FASTEN AT EACH END TO EXISTING
BOTTOM CHORD WITH LUS 44 HANGER
EX TRUSSES
EX TRUSS
BOTTOM CHORD
NEW 2X4 BLOCKING
LUS 24
HANGER AT
TRUSS, TYP
INSTALL OVERSIZED
PIPE BRACKET TO
STABILIZE SUPPORTS
LATERALLY. BRACKET
TO ALLOW PIPE TO
MOVE UP AND DOWN.
1/2" DIA ALL
THREAD HANGER
AT EACH CORNER
OF EQUIPMENT.
INSTALL BY
DRILLING A HOLE
THROUGH THE
CENTER OF THE
BEAM 1/8" LARGER
IN DIA THAN
HANGER.
NEW 4X10 BEAM
EX CEILING
INSTALL OVERSIZED WASHER AND NUT.
APPLY LOCTITE TO PREVENT SLIPPAGE.
EX WALL
TO AVOID VERTICAL REINF
FIELD LOCATE EX REBAR,
ADJUST LOUVER LOCATION
FAN LOUVER
20" SQUARE
NEW PAPER DAMS
TO RETAIN GROUT
FIELD GROUT ANY
OPEN CELLS FOUND
BELOW, BESIDE, OR
ABOVE NEW OPENING
EX CELL
WITH REINF
AND GROUT
8' - 0" 16' - 0" 8' - 0"
SECONDARY FRAMING
NOT SHOWN TO SUPPORT
EDGE WALL ALL AROUND
BEAM
G
IR
D
ER
G
IR
D
ER
BEAM
BEAM
BEAM
BEAM
BEAM
FIXED CONNECTION
OF COLUMN TO
GIRDER BEAM
TY
P
5'
D
EC
K
NOTES:
1. THIS IS ONLY A SUGGESTED FRAMING PLAN, MANUFACTURER TO DETERMINE FINAL
LAYOUT AND DESIGN.
2. ALL STEEL TO BE HOT DIP GALVANIZED AND PAINTED.
3. DELEGATED DESIGN TO INCLUDE THE ENTIRE CANOPY SUPERSTRUCTURE, FOUNDATION,
AND ATTACHMENT TO FOUNDATION. MANUF TO PROVIDE ALL FRAMING, FINISHES,
DRAINS, AND GUTTERS NECESSARY TO PROVIDE A WATER TIGHT STRUCTURE.
4. ALL FRAMING STEEL TO BE INSIDE CANOPY AND NOT EXPOSED TO WEATHER WITH THE
EXCEPTION OF THE COLUMNS.
TOP OF GIRDER ELEVATION = BOTTOM OF BEAM ELEVATION
RAIN GUTTER TYP AT
EACH COLUMN. SEE
CIVIL FOR CONNECTION
AND LOCATION
EX TRUSSES
EX TRUSS
BOTTOM CHORD
NEW BLOCKING. USE 2X4 BLOCKING AT
LIGHTS AND 4X4 BLOCKING AT DUCTWORK
LUS 24 HANGER AT TRUSS FOR
LIGHTS AND LUS 44 HANGER AT
TRUSS FOR DUCTWORK, TYP
EX CEILING
NATIONAL PARK SERVICE - INTERIOR REGION 1 - NATIONAL CAPITAL AREA
DESIGN AND PROJECT MANAGEMENT
UNITED STATES
OF
SHEET
DWG. NO.
DATE
DEPARTMENT OF THE INTERIOR
SUB SHEET NUMBERTITLE OF DRAWING
Mark Sheet InitialDateREVISION
DESIGNED
DRAWN
CHECKED
TITLE OF PROJECT
NAME OF PARK
LOCATION WITHIN PARK
21000 ATLANTIC
EAST POTOMAC MAINTENANCE YARD
REHABILITATION OF THE FUEL SYSTEMS
NATIONAL MALL AND MEMORIAL PARKS (NAMA)
TWW
SEP
APU
165425
254579
PMIS#
DULLES, VA 20166
BOULEVARD, SUITE 400
(703) 450-0800 www.alphacorporation.com
08.27.2021
S-05
TYP DETAILS & SECTIONS
1" = 1'-0"S-03 S-05
C Typ Drain in Concrete Slab 3/8" = 1'-0"S-03 S-05
B Slab at Garage Door 1" = 1'-0"S-03 S-05
A Concrete Curb Beneath Light Gauge Wall
NOT TO SCALE
1 Equipment Pad at Fuel Storage Tanks
NOT TO SCALE
2 Concrete Pad for Fuel Control Building
NOT TO SCALE
3 Typical Stud Bearing for Beams
NOT TO SCALE
4 Typical Blocking for Mechanical Equipment Support
NOT TO SCALE
5 New Louver Opening
NOT TO SCALE
6 FUEL CANOPY SUGGESTED FRAMING PLAN
NOT TO SCALE
7 Typical Blocking for Lighting and Duct Work Support
TOOL JOINT WHEN CAST
OR USE PREFORMED STRIP,
FILL WITH SEALANT
T
SUBGRADE
GRANULAR FILL
VAPOR RETARDER
WELDED WIRE FABRIC
SEE PLAN FOR SIZE
CUT WWF AT JOINT
1/
2" C
LR
T/
T/5
3/4" MIN
1/4" W x T/4 D
TOOL JOINT WHEN
CAST OR USE
PREFORMED STRIP,
FILL WITH SEALANT
1/4" W x T/4 D
T
SUBGRADE
GRANULAR FILL
VAPOR RETARDER
WELDED WIRE
FABRIC SEE
PLAN FOR
SIZE CUT WWF
AT JOINT
1/
2" C
LR EX SOG
SUBGRADE
GRANULAR FILL VAPOR RETARDER
PROVIDE ZIP-
STRIP IN JOINT
NON-SAG
POLYURETHANE
CAULK
NEW SOG
1/2" COMPRESSIBLE
JOINT MATERIAL
SEE ARCH
DWGS FOR
FINISHES
600S137-43 P
AT 16" OC
STUD WALL,
INSTALL
BRACING
PER DETAIL
8 AT 4' OC
BOTTOM TRACK, 14 GAUGE, 2" LEG
SEE BASE CONNECTION DETAIL 6
PLAN VIEW
MAXTRACK DEFLECTION TRACK, 14 GAUGE,
2 1/2" LEG LENGTH, OR APPROVED EQUAL
SEE DETAIL 7 FOR CONNECTION.
PROVIDE CONNECTION AT 32" OC.
INSTALL 2X4 BRACE. EXTEND TO TOP
CHORD OF TRUSS FOUR FEET AWAY.
FASTEN WITH (2) 12d TOENAILS AT
EACH CHORD. INSTALL 10' OC ON
EACH SIDE OF WALL.
EX TRUSS
BOTTOM
CHORD
INSTALL FLAT 2X4 TO TOP OF
BOTTOM CHORD OF EX TRUSS WITH
(2) 12D NAILS. INSTALL AT 10' OC AT
LOCATION OF DIAGONAL BRACE.
EXTEND ACROSS (6) TRUSSES.
SDS #10-16 AT EACH FLANGE
SDS #10-16 AT
EACH FLANGE
COPE FLANGES OF
CROSS STUD AS
REQUIRED
NON-LOAD
BEARING WALL
STUD PIECE
BOTTOM
CHORD OF
JOIST OR
TRUSS
2 1/2" DEFLECTION
TRACK, SEE DETAIL 10
1-1/2" X 16 GA., U-
CHANNEL BRIDGING
SPACING AS
REQUIRED
1-1/2" X 1-1/2" X 16
GA., CLIP ANGLE
FASTENED WITH (4)
SDS #10-16 AT EACH
FLANGE
TYPICAL STUD
TYPICAL STUD
TYP TRACK
(1) #8 SCREW PER
STUD FLANGE
PDPA WITH 0.157" SHANK
DIAMETER AND 1"
EMBEDMENT INTO CONC.
INSTALL IN CENTER OF
TRACK AT 16" OC.
ATTACH TRACK TO STRUCTURE WITH
(2) SDS #10-16 SCREWS AT EACH STUD
MAXTRACK DEFLECTION TRACK,
14 GAUGE, 2 1/2" LEG LENGTH,
OR APPROVED EQUAL
GAP TO ALLOW FOR
VERTICAL DEFLECTION
WALL STUD
D
EF
LE
C
TI
O
N G
AP
SIDE VIEW
(1) #8-18 WAFERHEAD
FRAMING SCREWS IN
EACH STUD FLANGE
EX
WALL T/ SLAB ELEV
SEE PLAN
GRANULAR FILL
VAPOR BARRIER
SOG, SEE PLAN
1#4 CONT
PROVIDE ZIP-
STRIP IN JOINT
NON-SAG POLYURETHANE CAULK
1/2" COMPRESSIBLE
JOINT MATERIAL
4'
0"
4MM FLAT
STEEL PANELS
FASCIA
BASE PLATE
BY MANUF
COLUMN SIZE
PER MANUF
FOUNDATIONS TO BE
DESIGNED BY MANUF
NOTES:
1. ALL STEEL TO BE HOT DIP GALVANIZED AND PAINTED.
2. DELEGATED DESIGN TO INCLUDE THE ENTIRE CANOPY
SUPERSTRUCTURE, FOUNDATION, AND ATTACHMENT TO FOUNDATION.
MANUF TO PROVIDE ALL FRAMING, FINISHES, DRAINS, AND GUTTERS
NECESSARY TO PROVIDE A WATER TIGHT STRUCTURE.
ALL STRUCTURAL SUPPORT TO BE DESIGNED BY MANUF.
SPACING, SEE CIVIL
TO OUT DIMENSIONS FOR CANOPY
SEE CIVIL DWGS FOR OUT
STEEL ROOF
PANELS, SLOPE
TO DRAIN
CANOPY COLOR TO BE
CHOSEN BY COR FROM
MANUF OPTIONS
ROOF PROFILE
SLOPE TO DRAINS
RAIN GUTTER TYP AT
EACH COLUMN. SEE
CIVIL FOR CONNECTION
SUBGRADE
#6 BARS AT
12" OC EW
NOTES:
1. SEE CIVIL DWGS FOR OIL-WATER SEPARATOR PAD LOCATION, SIZE,
AND ELEVATION OF SLAB BELOW GRADE.
2. PROVIDE POLYESTER OR STEEL HOLD-DOWN STRAPS IN
ACCORDANCE WITH OIL-WATER SEPARATOR MANUF
RECOMMENDATIONS. CONTRACTOR IS TO DETERMINE AND PROVIDE
SIZE AND QUANTITY OF HOLD DOWN STRAPS AND SIZE AND
STRENGTH OF ANCHOR BOLTS AND PLACEMENT IN ACCORDANCE
W…