This document is a complete set of construction drawings for the Lowell National Historical Park bathroom rehabilitation project. The project involves comprehensive renovation of restroom facilities across multiple buildings including the Visitor Center, Boott Counting House, and Mogan Cultural Center at various floor levels.
The scope of work encompasses demolition of existing fixtures, finishes, and systems followed by installation of new plumbing, mechanical, electrical, fire protection, and architectural components. Key deliverables include new water closets, lavatories, urinals, and integrated sink systems (primarily Sloan and Bradley brands); exhaust fans ranging from 50-140 CFM capacity with manual motor switches; LED lighting fixtures including recessed troffers, cove lights, and pendant-mounted units; new ceramic tile finishes with bullnose edges and grout lines; resinous flooring with 4-inch integrated bases; gypsum wall board partitions with various fire ratings (1-hour to 2-hour rated assemblies); and new fire protection sprinkler coverage with pendant and upright heads per NFPA-13 standards. The project includes coordination with multiple MEP (mechanical, electrical, plumbing) trades, phased construction sequencing, and strict attention to maintaining fire-smoke ratings on existing structures. Standard construction practices are specified throughout, including seismic restraints per specification 130541, manufacturer-recommended equipment installation, and comprehensive coordination with structural, architectural, and other building systems to minimize conflicts and ensure proper integration of all new work elements.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING INDEX
DRAWING NAME
G1 COVER SHEET
A0 GENERAL NOTES & LEGENDS
A1 DEMO PLANS
A2 DEMO RCP
A3 MOGAN CULTURAL CENTER DEMO PLANS AND RCP
A4 FLOOR PLANS
A5 RCP PLANS
A6 FINISH PLANS
A7 MOGAN CULTURAL CENTER PLANS AND RCP
A8 INTERIOR ELEVATIONS - VISITOR CENTER - 1st FLOOR
A9 INTERIOR ELEVATIONS - VISITOR CENTER - 2nd FLOOR
A10 INTERIOR ELEVATIONS - MOGAN CULTURAL CENTER
A11 INTERIOR ELEVATIONS - BOOTT COUNTING HOUSE
A12 PARTITION TYPES
A13 DOOR TYPES, FRAME TYPES & DETAILS
A14 INTERIOR FINISHES, ACCESSORY, FIXTURE
A15 RESTROOM DETAILS
M1 MECHANICAL GENERAL NOTES AND LEGEND
M2 MECHANICAL DEMOLITION PLAN
M3 MECHANICAL MOGAN DEMOLITION PLAN
M4 MECHANICAL NEW PLAN
M5 MECHANICAL MOGAN NEW PLAN
P1 PLUMBING GENERAL NOTES AND LEGEND
P2 PLUMBING DEMOLITION PLAN
P3 PLUMBING MOGAN DEMOLITION PLAN
P4 PLUMBING NEW PLAN
P5 PLUMBING MOGAN NEW PLAN
F1 FIRE PROTECTION GENERAL NOTES AND LEGEND
F2 FIRE PROTECTION DEMOLITION PLAN
F3 FIRE PROTECTION MOGAN DEMOLITION PLAN
F4 FIRE PROTECTION NEW PLAN
F5 FIRE PROTECTION MOGAN NEW PLAN
E1 ELECTRICAL LEGEND AND ABBREVIATIONS
E2 DEMOLITION FLOOR PLANS
E3 DEMOLITION LIGHTING PLANS
E4 DEMOLITION MOGAN CULTURAL CENTER PLANS
E5 FLOOR PLANS
E6 LIGHTING PLANS
E7 MOGAN CULTURAL CENTER PLANS
E8 SCHEDULES & DIAGRAMS
E9 SCHEDULES & DIAGRAMS
David Lieb Rectangle
David Lieb Rectangle
David Lieb Rectangle
David Lieb Rectangle
David Lieb Rectangle
David Lieb Rectangle
David Lieb Rectangle
David Lieb Rectangle
David Lieb Rectangle
David Lieb Rectangle
ELEV
25'-0"
GENERAL LEGEND
SPOT ELEVATION KEY
ENLARGED PLAN KEY
ALIGN KEY
DETAIL NUMBER
DRAWING NUMBER
ROOM NAME
ROOM NUMBER
REVISION KEY
DIMENSION LINE
DETAIL KEY:
ROOM KEY:
NOT IN CONTRACT
(NIC) SHADING
COLUMN LINE INDICATORS
PARTITION TYPE
DOOR NUMBER
SEALANT & BACKER ROD
SEALANT
INTERIOR ELEVATION KEY -
MULTIPLE
1"
S
S
WALL SECTION KEY
AX
LOUVER TYPE?
LIMIT OF WORK
AX
AX
ROOM NAME
A
AX
1A
S - South
SAFB - Sound Attenuation
Fiber Batts
SC - Solid Core
SCHED - Schedule
SCR - Screw
SCRN - Screen
SECT - Section
SF - Square Foot or Feet
SHT - Sheet
SHTG - Sheathing
SHV - Shelving
SIM - Similar
SM - Sheet Metal
SOW - Scope of Work
SPEC - Specifications
SQ - Square
SS - Stainless Steel
SSF - Solid Surface
STAG - Stagger
STC - Sound Transmission
Class
STD - Standard
STG - Storage
STL - Steel
STN - Stone or Stantec
STR - Structural
SUSP - Suspended
SVF - Sheet Vinyl Flooring
SYM - Symbol
SYMM - Symmetrical
SYS - System
S4S - Surface Four Sides
T - Treads (Stairs)
T&B - Top and Bottom
T&G - Tongue and Groove
TBD - To Be Determinedr
TC - Top of Concrete
TEL - Telephone
TEMP - Temporary
TF - Top of Footing
TFF - Top of Finished
Floor
THK - Thickness
THRES - Threshold
THRU - Through
TMPD - Tempered
T.O. - Top Of
TOC - Top Of Concrete
TOL - Tolerance
TOM - Top Of Masonry
TOP - Top of Pavement
TOS - Top Of Steel
TOSL - Top of Slab
TOW - Top Of Wall
TRANS - Translucent
TYP - Typical
U/S - Underside
UL - Underwriters
Laboratory
UNEX - Unexcavated
UNFIN - Unfinished
UON - Unless Otherwise
Noted
UPS - Uninterruptible
Power Supply
UV - Ultraviolet
VAC - Vacuum
VAN - Vanity
VB - Vapor Barrier or Vinyl
Base
VCT - Vinyl Composition
Tile
VER - Verify
VERT - Vertical
VEST - Vestibule
VIF - Contractor to Verify
In Field
VNR - Veneer
VOC - Volatile Organic
Compound
VR - Vapor Retarder
VWC - Vinyl Wall Covering
W - West
W/ - With
W/O - Without
WD - Wood
WP - Working Point
WT - Weight
WTH - Width
ETR - Existing to Remain
EX / EXIST - Existing
EXH - Exhaust
EXP - Expansion
EXT - Exterior
F/F - Face to Face
FA - Fire Alarm
FACP - Fire Alarm Control
Panel
FE - Fire Extinguisher
FEC - Fire Extinguisher
Cabinet
FF&E/FFE - Furniture
Fittings &
Equipment
FFL - Finished Floor Level
FHP - Full Height Partition
FHY - Fire HydrantFIN -
Finish
FIXT - Fixture
FLG - Flange
FLR - Floor
FO - Face of
FOC - Face of Concrete
FOF - Face of Finish
FOM - Face of Masonry
FOS - Face of Stud
FPRF - Fireproofing
FR - Fire Resistant
FRT - Fire Retardant
Treated
FS - Full Size
FSH - Fire Sprinkler Head
FSTP - Firestopping
FT - Foot or Feet
FTR - Fin Tube Radiation
FURN - Furniture
FURR - Furring
FUT - Future
G - Gas
GA - Gauge
GALV - Galvanized
GC - General Contractor
GEN - Generator
GFI/GFCI - Ground Fault
(Circuit) Interrupter
GFRG - Glass Fiber
Reinforced Gypsum
GL - Glass
GND - Ground
GR - Grade
GRL - Grille
GRTG - Grating
GSKT - Gasket
GT - Grout
GWB - Gypsum Wall Board
HC - Hollow Core
HDBD - Hardboard
HDWD - Hardwood
HDW - Hardware
HGR - Hanger
HT - Height
HM - Hollow Metal
HMD - Hollow Metal Door
HNDRL - Handrail
HO - Hold Open
HORIZ - Horizontal
HP - High Point
HVAC - Heat, Ventilation &
Air Conditioning
ID - Inside Diameter
IF - Inside Face
IN - Inch or Inches
INSUL - Insulation
INT - Interior
JAN - Janitor
JT - Joint
KD - Knocked Down
KIT - Kitchen
KO - Knockout
KOP - Knockout Panel
KPL - Kickplate
L - Length or Left
LAD - Ladder
LAM - Laminate
LAV - Lavatory
LB - Pound
LBL - Label
LED - Light Emitting Diode
LF - Linear Foot or Feet
LH - Left Hand
LHR - Left Hand Reverse
LIN - Linear
LONG - Longitudinal
LP - Low Point
LT - Light
LTG - Lighting
LTWT - Lightweight
LVR - Louver
& - And
< - Angle
@ - At
C - Center Line
Ø - Diameter
# - Pound
± - Tolerance Dimension
A/E - Architect /
Engineer
AC - Air Conditioning
ACBL - Accessible (ADA
Compliant)
ACM - Asbestos Containing
Material
ACOUS - Acoustical
ACT - Acoustic Ceiling Tile
ADA - The Americans with
Disabilities Act
ADBL - Adaptable (ADA
Compliant)
ADDL - Additional
ADH - Adhesive
ADJ - Adjustable
ADJC - Adjacent
AFF - Above Finished
Floor
AH - Air Handler
ALUM - Aluminum
ALT - Alternate
ANOD - Anodized
AP - Access Panel
APPROX - Approximately
ARCH - Architect
ASC - Above Suspended
Ceiling
ASSY - Assembly
AVB - Air Vapor Barrier
BD - Board
BDY - Boundary
BETW - Between
BLDG - Building
BLKG - Blocking
BM - Beam
BO - By Others
BOD - Basis of Design
BOH - Back of House
BOT - Bottom
BYND - Beyond
C/C - Center to Center
CFCI - Contractor
Furnished/ Contractor
Installed
CG - Corner Guard
CHAN - Channel
CHFR - Chamfer
CIP - Cast in Place
CJ - Control Joint
CL - Center Line
CLG - Ceiling
CLO - Closet
CLR - Clear
CMPST - Composite
COL - Column
COMP - Compressible
CONC - Concrete
CONN - Connection
CONSTR - Construction
CONT - Continuous
CONTR - Contractor
COORD - Coordinate
CORR - Corridor
CPRS - Compressible or
Compression
CPT - Carpet
CSK - Countersunk
CSMT - Casement
CTR - Center
DBL - Double
DEMO - Demolition
DEPT - Department
DIA - Diameter
DIM - Dimension
DIV - Division
DN - Down
DO - Ditto
DOP - Door Opening
DR - Door
DST - Door Stop
DTL - Detail
DWG - Drawing
E - East
EA - Each
EL/ELEV - Elevation
ELEC - Electrical
EL/ELEV - Elevator
EMER - Emergency
ENGR - Engineer
ENTR - Entrance
EP - Electrical Panel
EQ - Equal
EQUIP - Equipment
MACH - Machine
MAINT - Maintenance
MAS - Masonry
MATL - Material
MAX - Maximum
MDF - Medium Density
Fiberboard
MDO - Medium Density
Overlay
MECH - Mechanical
MED - Medium
MEL - Melamine
MEMB - Membrane
MEZZ - Mezzanine
MFR - Manufacturer
MIN - Minimum
MISC - Miscellaneous
ML - Metal Lath
MLDG - Molding
MLWK - Millwork
MO - Masonry Opening
MTD - Mounted
MTL - Metal
MTR - Mortar
MULL - Mullion
MVBL - Movable
N - North
NA - Not Applicable
NAT - Natural
NIC - Not In Contract
NO - Number
NOM - Nominal
NTS - Not To Scale
OA - Overall
OC - On Center
OD - Outside Diameter
OF - Outside Face
OFCI - Owner
Furnished/Contractor
Installed
OFF - Office
OH - Overhead
OPNG - Opening
OPP - Opposite
P&S - Power & Signal
PAR - Parallel
PB - Particle Board
PC - Precast
PERF - Perforated
PERIM - Perimeter
PERP - Perpendicular
PL - Plate
PLAM - Plastic Laminate
PLAS - Plaster
PLBG - Plumbing
PLYWD - Plywood
PM - Pressed Metal
PNEU - Pneumatic
PNL - Panel
POL - Polished
POLY - Polyethelene
POP - Press-On Plate
PR - Pair
PRCST - Precast
PREFAB - Prefabricated
PREFIN - Prefinished
PT - Pressure Treated or
Post Tension
PTD - Painted
PTN - Partition
PV - Photovoltaic
PVG - Paving
QTY - Quantity
QUAL - Quality
R&R - Remove & Replace
R - Radius or (Stair) Risers
RAD - Radiator
RBR - Rubber
RCP - Reflected Ceiling Plan
RDG - Ridge
REC - Recessed
REF - Reference
REINF - Reinforced or
Reinforcing
REM - Removable
REQD - Required
REQMTS - Requirements
RESIL - Resilient
RF - Resilient Flooring
RFG - Roofing
RH - Right Hand
RHR - Right Hand Reverse
RLG - Railing
RM - Room
RO - Rough Opening
RSIC - Resilient Sound
Isolation Clip
RTN - Return
ABBREVIATIONS
1. MATERIALS AND PRODUCTS, CALLED OUT TO BE INSTALLED ON THE
DRAWINGS ARE TO BE NEW UON CONTRACTING OFFICER/DESIGNER WILL
PROVIDE SCHEDULE OF SALVAGED ITEMS, IF ANY, THAT ARE TO BE RE-
USED ON THIS PROJECT.
2. EXISTING GWB CEILINGS TO REMAIN TO BE PATCHED AND REPAIRED TO A
FINISH LEVEL CONSISTENT WITH NEW WORK.
3. DOWN LIGHTS, WALL WASHERS, SMOKE DETECTORS, EXIT SIGNS, AND
OTHER CEILING MOUNTED DEVICES TO BE CENTERED IN CEILING TILES AND
GWB SOFFITS, UON.
4. SPRINKLER HEADS TO BE CENTERED IN CEILING TILES AND GWB SOFFITS
IN BOTH DIRECTIONS UON.
5. DIMENSIONS OF FIXTURES, DEVICES, ETC. ARE TO CENTERLINE OF
FIXTURE, UON WHERE ITEMS ARE IN LINE, CENTERLINE OF ITEMS OR
GROUP OF ITEMS TO ALIGN, UON.
6. SPRINKLER HEADS SHOWN FOR ARCHITECTURAL DESIGN INTENT ONLY, NOT
FOR CODE DISTRIBUTION. SEE FIRE PROTECTION CONTRACT DRAWINGS
AND APPROVED SHOP DRAWINGS FOR DISTRIBUTION AND HYDRAULIC
CALCULATIONS.
RCP NOTES
DEMOLITION PLAN NOTES
1. THESE DEMOLITION DRAWINGS HAVE BEEN COMPILED FROM THE BEST
AVAILABLE INFORMATION AND ARE NOT INTENDED TO LIMIT THE SCOPE OF
THE WORK. CONTRACTOR TO INSPECT THE SITE AND SUBMIT ALL
DEMOLITION SCOPE QUESTIONS PRIOR TO BIDDING AND VERIFY THE
INFORMATION HEREIN SUPPLIED.
2. INTENT IS TO REMOVE EVERYTHING NECESSARY TO ALLOW NEW
CONSTRUCTION TO BE ACCOMPLISHED. SEE DRAWINGS SHOWING NEW
CONSTRUCTION.
3. PRIOR TO CARRYING OUT DEMOLITION WORK ON PARTITIONS INDICATED TO
BE REMOVED, EXISTING FRAMING TO BE EXPOSED FOR CONTRACTING
OFFICER/ENGINEER’S REVIEW.
4. REFER TO STRUCTURAL DOCUMENTS FOR REMOVAL OF ANY BUILDING
ELEMENTS AND REVIEW WITH CONTRACTING OFFICER/STRUCTURAL ENGINEER
PRIOR TO DEMOLITION.
5. DO NOT REMOVE ANY STRUCTURAL ELEMENTS (FLOORS, COLUMNS, BEAMS,
LOAD BEARING WALLS, ETC.) WITHOUT THE REVIEW AND APPROVAL OF THE
CONTRACTING OFFICER AND STRUCTURAL ENGINEER.
6. LOCATIONS OF NEW OPENINGS ARE SHOWN ON DRAWINGS. REVIEW FOR
COORDINATION WITH NEW CONSTRUCTION AND NOTIFY ARCHITECT OF ANY
DISCREPANCIES PRIOR TO DEMOLITION.
7. PROTECT EXISTING FINISHES, TRIM, FIXTURES, AND EQUIPMENT TO REMAIN.
8. SEE PLAN AND PLAN NOTES FOR ITEMS TO BE SALVAGED. CONFIRM WITH
OWNER ALL ITEMS TO BE SALVAGED AND RETAINED. DO NOT DAMAGE.
9. PROTECT OR REMOVE AND STORE EXISTING PERIMETER WINDOW
TREATMENTS. NOTIFY LANDLORD OF ANY DAMAGED OR NON-FUNCTIONING
BLINDS IN WRITING PRIOR TO COMMENCING WORK.
10. REMOVE FINISH FLOORING MATERIAL AND BACKERS, UON REMOVE
EXISTING ADHESIVES AS REQUIRED TO ALLOW PROPER INSTALLATION OF
NEW FLOORING, PER MANUFACTURER’S REQUIREMENTS.
11. REMOVE EXISTING WALL BASE, UON.
12. REMOVE EXISTING APPLIED WALL FINISHES, UON.
13. REMOVE EXISTING LIGHT FIXTURES, UON.
14. REMOVE ELECTRICAL AND SIGNAL DEVICES AND BOXES AT FLOORS AND
EXISTING WALLS TO REMAIN, UON.
15. MAINTAIN EXISTING PERIMETER SOFFIT/WINDOW TREATMENT DETAIL, UON.
16. EXISTING COLUMN ENCLOSURES TO REMAIN, UON.
TYPICAL MOUNTING LOCATIONS
1'-6"
4'-0"
6'-8"
FIRE ALARM
ANNUNCIATION
DEVICE
THERMOSTATS AND
WALL PHONES
LIGHTING SWITCHES
FIRE ALARM
PULL STATION
RECEPTACLES
TELE-DATA OUTLET
/ COMPUTER
INTERFACE
FINISH FLOOR
NOT TO SCALE
3'-0"
FIRE EXTINGUISHER
CABINET
CARD READER
MIN
6" DOOR & FRAME
MIN. @ ALL DEVICES FROM CORNER
1'-6"
1. INSTALL DEVICES AS INDICATED ABOVE UON.
2. MEASURE MOUNTING HEIGHTS FROM CENTERLINE OF DEVICE TO FINISH
FLOOR UON.
3. INSTALL DEVICES ON A COMMON VERTICAL CENTERLINE WHEREVER
POSSIBLE.
4. DIMENSIONS AT LOAD CENTER ARE TO EDGE OF DOOR.
1. EACH BIDDER SHALL VISIT THE SITE AND EXAMINE THE SITE TO ENSURE THEIR KNOWLEDGE OF THE
CONDITIONS AFFECTING THE WORK.
2. DETAILS AND SECTIONS ON THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS. DETAILS NOTED "TYPICAL"
OR "TYP" IMPLY THE SAME CONDITION IS REPEATED AT OTHER LOCATIONS. DETAILS NOTED “SIMILAR” OR
“SIM” IMPLY THE CONDITION IS TREATED SIMILARLY IN OTHER LOCATIONS BUT WITH SLIGHT MODIFICATIONS
TO BE MADE BY CONTRACTOR TO ACCOMMODATE MINOR VARIATIONS.
3. MATERIALS AND PRODUCTS CALLED OUT TO BE INSTALLED ON THE DRAWINGS ARE TO BE NEW UON
CONTRACTING OFFICER WILL PROVIDE SCHEDULE OF SALVAGED ITEMS, IF ANY, THAT ARE TO BE RE-USED ON
THIS PROJECT.
4. SIDES OF DOOR OPENINGS TO BE A MINIMUM OF 6" FROM NEAREST PERPENDICULAR PARTITION, UON.
5. REVIEW LAYOUTS FOR PARTITIONS IN FIELD WITH THE ARCHITECT/DESIGNER PRIOR TO START OF
CONSTRUCTION.
6. ALIGN CENTERLINES OF FIRE EXTINGUISHER CABINETS AND MEP/FP DEVICES ON WALLS IN THE SAME
LOCATION.
7. WHERE NEW PARTITIONS ABUT EXISTING SURFACES, REMOVE EXISTING CORNER BEAD AND PROVIDE SMOOTH
FINISH AT INTERSECTION.
8. PATCH PARTITIONS TO REMAIN WHERE WALL RECEPTACLES, FACE PLATES, WALL BASE, ETC. ARE REMOVED.
9. EXISTING FLOORS, PARTITIONS, CEILINGS, INTERIOR COLUMNS, AND CORRIDOR WALLS TO BE PATCHED AND
REPAIRED AS NEEDED TO MAINTAIN ORIGINAL ACOUSTICAL AND RATED FIRE/SMOKE DESIGN INTENT.
PENETRATIONS AND JOINTS ARE TO BE SEALED TO MAINTAIN FIRE/SMOKE RATING AND ACOUSTICAL RATING.
10. EXISTING WALLS, COLUMN ENCLOSURES, SOFFITS ETC. TO REMAIN ARE TO BE PATCHED AND REPAIRED TO
MEET REQUIREMENTS OF NEW SURFACES UON.
11. DOOR NUMBERS TO CORRESPOND TO ROOM NUMBERS, UON.
12. REINSTALL REMOVED PERIMETER WINDOW TREATMENT. ADJUST/MODIFY/REPLACE WINDOW TREATMENTS AS
REQUIRED TO ACCOMMODATE NEW CONSTRUCTION.
13. DIMENSIONS:
A. DIMENSIONS ARE TO FINISHED FACE OF PARTITION UON
B. DRAWINGS ARE NOT TO BE SCALED; VERIFY ANY MISSING OR CONFLICTING WRITTEN DIMENSIONS WITH THE
CONTRACTING OFFICER/DESIGNER PRIOR TO CONSTRUCTION.
C. NOTIFY ARCHITECT/DESIGNER OF CONDITIONS WHERE CLEAR OR CRITICAL DIMENSIONS ARE DESIGNATED
BUT CANNOT BE MET OR WHERE CORRIDOR/AISLE WIDTH CANNOT MEET THE MINIMUM REQUIREMENTS
(3'-8" UON).
D. MAINTAIN FINISH FLOOR BASE ELEVATION THROUGHOUT THE CONTRACT AREA SUCH THAT DIMENSIONS
INDICATED AS ABOVE FINISH FLOOR ARE AT THE SAME ELEVATION.
14. PROVIDE FIRE EXTINGUISHERS (WITH CABINETS) IN QUANTITIES AND LOCATIONS ON DWGS, BUT IN NO CASE
LESS THAN AMOUNT REQUIRED BY CODE. REVIEW FINAL LOCATIONS WITH THE ARCHITECT/DESIGNER PRIOR
TO START OF CONSTRUCTION. PARTITION DEPTH AT FIRE EXTINGUISHER CABINET LOCATIONS TO ACCOMMODATE
FULL CONCEALMENT OF RECESSED CABINETS, UON.
PARTITION PLAN NOTES
1. REFER TO ELEVATIONS, ENLARGED PLANS, DETAILS, SCHEDULES AND
SPECIFICATIONS FOR ADDITIONAL FINISH INFORMATION.
2. FLOORING TRANSITIONS AT DOOR OPENING TO OCCUR UNDERNEATH
DOOR, UON.
3. INCLUDE FLOORING TRANSITION STRIP AT ALL EXISTING DOOR OPENINGS
TO NIC SPACES. CONFIRM MATERIAL, PROFILE, AND FINISH WITH
CONTRACTING OFFICER.
4. DO NOT PAINT OVER FIRE RATING TAGS ON RATED DOORS AND FRAMES.
5. WALLS TO BE PAINTED EGGSHELL FINISH, UON
DOORS TO BE PAINTED SEMI-GLOSS, UON
FRAMES TO BE PAINTED SEMI-GLOSS, UON
CEILINGS TO BE PAINTED EGGSHELL FINISH, UON
6. AT PARTITIONS AND GWB SOFFITS/CEILINGS THAT HAVE BEEN PATCHED,
PRIME AND PAINT ENTIRE SURFACE.
7. ALL PAINTED WALL FINISHES GWB TO RECEIVE LEVEL 5 FINISH PRIOR
TO INSTALLATION OF FINISH.
FINISH PLAN NOTES
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET DRAWING NO.
PMIS SHEET
OF
NO.
99B
LOWE 475
187375
A0
GENERAL NOTES &
LEGENDS
NPS LOWE TOILETS
PITRE
PITRE
HICKS
05/18/2023
MEN'S TOILET WOMEN'S TOILET
SERVICE
AREA
CORRIDOR
JANITOR
EXITWAY
F.D.
F.D.
JANITOR
MEN'S TOILET
WOMEN'S TOILET
'-2
F.D.
F.D.
SERVICE
AREA
CORRIDOR
JANITOR
EXITWAY
WOMEN'S TOILETMEN'S TOILET
MEN'S TOILET WOMEN'S TOILET
DEMOLITION RCP LEGEND
EXISTING CEILING TO BE REMOVED
EXISTING PARTITION TO REMAIN
EXISTING ELEMENT TO BE REMOVED
DEMOLITION PLAN LEGEND
EXISTING DOOR TO REMAIN
EXISTING DOOR TO BE REMOVED
EXISTING FLOOR FINISH TO BE REMOVED
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET DRAWING NO.
PMIS SHEET
OF
NO.
99B
LOWE 475
187375
A3
MOGAN CULTURAL
CENTER DEMO PLANS
AND RCP
NPS LOWE TOILETS
Designer
Author
Checker
05/18/2023
1/4" = 1'-0"A3
1 MOGAN CULTURAL CENTER - 1ST FLOOR DEMO
1/4" = 1'-0"A3
2 MOGAN CULTURAL CENTER - 3RD FLOOR DEMO
1/4" = 1'-0"A3
3 MOGAN CULTURAL CENTER 1ST FLOOR DEMO RCP
1/4" = 1'-0"A3
4 MOGAN CULTURAL CENTER 2ND FLOOR DEMO RCP
GENERAL DEMOLITION NOTES:
1. REMOVE ALL FINISHES, FIXTURES AND ACCESSORIES.
REFERENCE MEP DRAWINGS FOR ADDITIONAL INFORMATION.
0' 2' 4' 8'
George Little Callout Sawcut and carefully remove portions of CMU chase wall (approx. 50 sf each room) to gain plumbing access. Cut/cap existing supply and waste piping behind wall. Install new fixture carriages, at new locations. Extend existing piping to new fixture location. Refer to A7, A10, and A14 for additional notes and locations (both rooms). Infill walls with matching size CMU/mortar, coursing to match existing. Provide access panels for supply line maintenance at fixtures.
George Little Callout Cap existing piping at demolished second sink behind wall. Infill walls with matching size CMU/mortar, coursing to match existing (both rooms).
F
OS
OS
OS OS
A108 A10 2
MCC 113
MEN'S TOILET
MCC 114
WOMEN'S TOILET
SERVICE
AREA
CORRIDOR
JANITOR
EXITWAY
ACCUATED DOOR
OPENER
MCC 114MCC 113
M
IN
C L R
'-0
/8
'-6
M
IN
C L R
'-0
/8
'-0
F.D.
F.D.
A10 10
A1016
JANITOR
MCC 218
MEN'S TOILET MCC 219
WOMEN'S TOILET
ACUATED DOOR
OPENER.
'-0
MCC 219MCC 218
M
IN
C L R
'-0
M
IN
C L R
'-0
F.D.
F.D.
'-6
ACT-1 8' - 3" ACT-1 8' - 3"
LIGHTING, SEE ELEC
L2L2
CORRIDOR
JANITOR
EXITWAY
SERVICE
AREA
L1L1
L6
L6
L6 L6
L6
L6
ACT-1 8' - 0" ACT-1 8' - 0"
L2 L2
L1 L1
L6
L6
L6L6
L6
L6
RSF
RSF
MCC 218
MEN'S TOILET MCC 219
WOMEN'S TOILET
JANITOR
RSF
RSF
LIGHTING LEGEND
L1
L2
L5, L7
L4
RECESSED LINEAR LED SLOT
RECESSED LED
2'x2' LED TROFFER
LED LINEAR PENDANT - (4', 6')
2' x 6" WALL MOUNTED FIXTURE
L6 2' x 6" LAY-IN FIXTURE
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET DRAWING NO.
PMIS SHEET
OF
NO.
99B
LOWE 475
187375
A7
MOGAN CULTURAL
CENTER PLANS AND RCP
NPS LOWE TOILETS
Designer
Author
Checker
05/18/2023
A7
MOGAN CULTURAL CENTER -
1ST FLOOR
A7
MOGAN CULTURAL CENTER -
3RD FLOOR
A7
MOGAN CULTURAL CENTER
1ST FLOOR RCP
A7
MOGAN CULTURAL CENTER
2ND FLOOR RCP
A7
FINISH PLAN-MOGAN
CULTURAL CENTER-1ST FLR
FINISH PLAN
A7
FINISH PLAN-MOGAN
CULTURAL CENTER-2ND FLR
0' 2' 4' 8'
David Lieb Rectangle
David Lieb Rectangle
David Lieb Rectangle
David Lieb Rectangle
David Lieb Callout
REF DETAIL A-15 - ACT TO EXTEND FULL ROOM, RECESSED LIGHTING (BOTH ROOMS)
David Lieb Callout
REF DETAIL A-15 - ACT TO EXTEND FULL ROOM, RECESSED LIGHTING (BOTH ROOMS)
George Little Line
George Little Line
George Little Line
George Little Line
George Little Line
George Little Line
George Little Line
George Little Line
George Little Callout Note new location for toilets.
George Little Line
George Little Line
George Little Line
George Little Line
George Little Callout Utilize plumbing from this demolished sink
George Little Line
George Little Line
George Little Line
George Little Line
George Little Line
George Little Line
George Little Line
George Little Line
George Little Line
George Little Line
George Little Line
George Little Line
George Little Callout Utilize plumbing from this demolished sink
George Little Callout Note new location for toilet and urinal.
George Little Callout Utilize plumbing from this demolished sink
George Little Line
George Little Line
George Little Callout Utilize plumbing from this demolished sink
George Little Line
George Little Line
4" INTEGRAL BASE, TYP
'-9
TL
LIGHT COVE, TYP
AC-7
2'-11 3/4"
PT
4'-0"
SURFACE MOUNTED
DOOR ACCUATOR
M A
X
'-0
AC-16
PATCH IN-FILL CMU
'-9
TL
PT
AC-11
AC-2
'-9
TL
AC-9
2'-0" 2'-2"
MCC 114
AC-2
AC-11
AC-12
TL
PT
'-9
AC-16
1'-6" 2'-5 3/8"P-1
4'-9"
'-0
EQ EQ
4" INTEGRAL BASE, TYP
'-9
TL
PT
AC-7
3'-0"
AC-12
AC-2
AC-11
MCC 113
'-9
TL
PT
P-1
4'-10"
'-0
2'-7 3/4" 3'-11 3/4" 1'-6"
EQ EQEQ EQ
AC-2
AC-5
'-9
TL
PT
AC-9
1'-11 1/2"
AC-11
2'-2"
PT
1 AC-16
4'-0"
SURFACE MOUNTED
DOOR ACCUATOR
M A
X
'-0
PATCH IN-FILL CMU
'-9
TL
'-9
TL
PT
AC-7
10 5/8"
EQ EQ
PT
SURFACE MOUNT
DOOR ACCUATOR
M A
X
'-0
1'-8 3/4"2'-0"
EXISTING METAL ACCESS PANEL
PATCH IN-FILL CMU
'-9
TL
PT
4" INTEGRAL BASE, TYP
PROVIDE PRIVACY FILM AT
WINDOWS, TYP
AC-9
EQEQ
'-9
TL
1'-9 1/2"
'-9
AC-11 AC-12
TL
PT
1 AC-2
P-1
'-0
3'-11 7/8"
3'-5 1/2" 1'-6"
'-9
TL
PT
AC-12
AC-11
'-9
TL
PT
P-1
AC-16
AC-2
4'-0"
2'-10 1/4" 3'-5 1/2"
'-0
EQ EQEQ EQ
2'-3 1/8"
PT
1EXISTING WINDOW
4" INTEGRAL BASE, TYP
LIGHT COVE, TYP
EQ EQ
'-9
TL
AC-16 AC-7
PT
5'-11 1/2"
3'-10 1/2"
SURFACE MOUNTED
DOOR ACCUATOR
M A
X
'-0
PATCH IN-FILL
CMU
'-9
AC-9
TL
EQ EQ
2'-5 3/4"
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET DRAWING NO.
PMIS SHEET
OF
NO.
99B
LOWE 475
187375
A10
INTERIOR ELEVATIONS -
MOGAN CULTURAL
CENTER
NPS LOWE TOILETS
PITRE
PITRE
HICKS
05/18/2023
A10
MOGAN 1ST FLOOR WOMEN'S
NORTH
A10
MOGAN 1ST FLOOR WOMEN'S
EAST
A10
MOGAN 1ST FLOOR WOMEN'S
SOUTH
A10
MOGAN 1ST FLOOR WOMEN'S
WEST
A10
MOGAN 1ST FLOOR MEN'S
NORTH
A10
MOGAN 1ST FLOOR MEN'S
EAST
A10
MOGAN 1ST FLOOR MEN'S
SOUTH
A10
MOGAN 1ST FLOOR MEN'S
WEST
A10
MOGAN 2ND FLOOR WOMEN'S
NORTH
A10
MOGAN 2ND FLOOR WOMEN'S
EAST
A10
MOGAN 2ND FLOOR WOMEN'S
SOUTH
A10
MOGAN 2ND FLOOR WOMEN'S
WEST
A10
13 MOGAN 2ND FLOOR MEN'S
A10
MOGAN 2ND FLOOR MEN'S
EAST
A10
MOGAN 2ND FLOOR MEN'S
SOUTH
A10
MOGAN 2ND FLOOR MEN'S
WEST
GENERAL NOTES:
1. REFER TO A14 FOR ACCESSORY SCHEDULE AND
MOUNTING DETAILS.0' 2' 4' 8'
George Little Rectangle
George Little Rectangle
George Little Rectangle
George Little Rectangle
George Little Rectangle
George Little Rectangle
George Little Callout Infill wall w/CMU behind new ceramic tile.
George Little Callout Infill wall w/CMU behind new ceramic tile.
George Little Callout Cap plumbing, patch wall w/CMU
George Little Callout Move plumbing for toilets over, patch wall w CMU behind new ceramic tile.
George Little Rectangle
George Little Rectangle
George Little Callout Infill wall w/CMU behind new ceramic tile.
George Little
Infill wall w/CMU behind new ceramic tile.
SEE PLAN FOR
PARTITION TYPE
KERF BLOCKING TO
ALLOW FOR
INSTALLATION TIGHT
TO GWB
PROVIDE 3/4" FRT
PLYWOOD BLOCKING
MAINTAIN CONTINUITY
OF PARTITION WITH
HIGHEST PRIORITY
LOWEST PRIORITY. SEE
PARTITION PLAN FOR TYPE.
HIGHEST PRIORITY. SEE
PARTITION PLAN FOR TYPE.TWO HOUR FIRE & SMOKE PARTITION PRIORITY 1 - HIGHEST
WALL PRIORITY LEGEND
TWO HOUR FIRE PARTITION
TWO HOUR SHAFT WALL
ONE HOUR FIRE & SMOKE PARTITION
ONE HOUR FIRE PARTITION
PRIORITY 2
PRIORITY 3
PRIORITY 4
NON-RATED PARTITION PRIORITY 5 - LOWEST
BRACING AT EACH SET OF STUDS
(48"OC MAX. VERT SPACING)
41 DOUBLE STUD PARTITION
S
1-5/8" NON-LOAD BEARING MTL
FRAMING @ 16" OC MAX, L/240
MAX, SEE SPEC
FINISH FLOORING. (SEE FINISH SCHEDULE)
1 LAYER OF 5/8" GWB, EACH SIDE
S
SS
EXISTING DECK
SLIP-JOINT FOR DEFLECTION. TYPICAL.
S STD SEALANT AT PARTITIONS
PENETRATIONS ABOVE CEILING:
TYPE 'A', UNLESS RATED
TYPE 'A' SAFB (3 1/2" BATT EACH SIDE)
CERAMIC TILE ON THISET, 1/2" CEMENT BACKER BOARD
BULLNOSE EDGE TILE, TYP
EXISTING DECK
3-5/8" NON-LOAD BEARING MTL FRAMING @
16" OC MAX, L/240 MAX, SEE SPEC
PROJECTION OF CEILING.
(REFER TO FINISH SCHEDULE FOR TYPE)
TYPE 'A' SAFB (FULL STUD DEPTH)
STD SEALANT AT PARTITIONS THAT ARE NEITHER
TYPE 'A' NOR RATED AND ACOUSTIC SEALANT AT
TYPE 'A', UNLESS RATED
FINISH FLOORING. (SEE FINISH SCHEDULE)
1 LAYER, 5/8" TYPE X GWB, EACH SIDE
S
SLIP-JOINT FOR
DEFLECTION.
2A
2 38-42 STC1HR RATED (UL DESIGN #U465)
W/ ACOUSTICAL INSUL. & 1HR RATED (UL DESIGN #U465) 43-48 STC
1A
1 38-42 STCSINGLE STUD PARTITION
W/ ACOUSTICAL INSULATION 43-48 STC
SS
SS
PENETRATIONS ABOVE CEILING:
1. TYPE 'A', UNLESS RATED: CONT. FILL ANNULAR
OPENING W/SAFB & ACOUSTIC SEALANT
2. RATED PARTITION: LISTED THRU-PENETRATION
FIRESTOP SYSTEM TO MAINTAIN REQUIRED RATING
FLOOR TO PARTITION:
RATED PARTITION: CONT. LISTED FIRE-RESISTIVE
JOINT SYSTEM TO MAINTAIN REQUIRED RATING
1B 6" STUD W/ ACOUSTICAL INSULATION 43-48 STC
CERAMIC TILE ON THISET, 1/2" CEMENT BACKER BOARD
23A
23 SING. STUD FURRING PARTITION
WITH ACOUSTICAL INSULATION
EXISTING DECK
2-1/2" NON-LOAD BEARING MTL FRAMING,
16" OC MAX, L/240 MAX, SEE SPEC
PROJECTION OF CEILING.
(SEE FINISH SCHEDULE FOR TYPE)
FINISH FLOORING. (SEE FINISH SCHEDULE)
1 LAYER OF 5/8" GWB. ONE SIDE ONLY
S
SLIP-JOINT FOR DEFLECTION
EXISTING PERIMETER EXTERIOR WALL OR INTERIOR BARRIER WALL
(SEE PLANS FOR LOCATIONS)
S
INTERIOR SIDE
S
STD SEALANT AT PARTITIONS THAT ARE NEITHER
TYPE 'A' NOR RATED AND ACOUSTIC SEALANT AT
TYPE 'A', UNLESS RATED
TYPE 'A' SAFB (FULL STUD DEPTH)
BOOTT COUNTING, ONE LAYER OF 5/8" ON
BACK SIDE, PTD WHITE. SEE PLANS
CERAMIC TILE ON THISET, 1/2" CEMENT BACKER
BOARD
Level 1
0"
Level 1
0' - 0"
'-1
/4
NEW SANITARY LINE. REF
PLUMBING DRAWINGS
TYPE 1A PARTITION
THINSET CERAMIC TILE
INTEGRAL COVE BASE (1" RADIUS)
LGMF INSTALLED ON FLAT TO
CREATE CHASE FOR SANITARY LINE
CONT EPOXY FLOORING UP
AND ONTO LEDGE
EXISTING DECK
74 EXISTING CMU WALL
RESINOUS FLOORING AND 4"
INTEGRATED BASE
PROJECTION OF CEILING.
(SEE FINISH SCHEDULE FOR TYPE)
CERAMIC TILE ON THINSET; SEE ELEVATIONS
FOR HEIGHT:
1/2" CEMENT BACKER BOARD ADHERED AND
MECHANICALLY ATTACHED TO EXISTING CMU
1/2" GWB ADHERED AND MECHANICALLY ATTACHED
TO EXISTING CMU
EXISTING CMU WALL
S
EXISTING DECK
75 EXISTING EXTERIOR MASONRY
RESINOUS FLOORING AND 4"
INTEGRATED BASE
CERAMIC TILE ON THINSET; SEE ELEVATIONS
FOR HEIGHT:
1/2" CEMENT BACKER BOARD ON 1/2"
FURRING STRIPS
1/2" GWB ON 1/2" FURRING STRIPS
EXISTING EXTERIOR MASONRY WALL
S
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET DRAWING NO.
PMIS SHEET
OF
NO.
99B
LOWE 475
187375
A12
PARTITION TYPES
NPS LOWE TOILETS
PITRE
PITRE
HICKS
05/18/2023
A12
1 PTN - CONCEALED BLOCKING
A12
2 PTN - PRIORITY KEY
1 1/2" = 1'-0"A12
5 BOOTT COUNTING - WALL BASE AT PLUMBING DRAIN
2" 2"
HM1
FRAME TYPESDOOR TYPES
F
FLUSH
NOTES:
-REFER TO DOOR SCHEDULE FOR DOOR HEIGHTS AND WIDTHS.
-EXISTING DOORS TO REMAIN TO BE CLEANED AND REFINISHED AS NECESSARY.
-EXISTING DOOR FRAMES TO REMAIN TO BE CLEANED, PREPPED AND REPAINTED.
-REFER TO SPECIFICATION SECTION 101423 FOR SIGNAGE TYPES
AL1SP
SLIDING POCKET
DOOR
LV
SINGLE
LOUVER
6" 6"
UNDERCUT
2"2"
4"
'-8
4"
'-8
SIGN SIGN
1. NEW HARDWARE TO MATCH EXISTING TO REMAIN, UON
2. DOOR LEVERS TO BE MOUNTED AT THE SAME HEIGHT AS EXISTING.
3. COORDINATE ACCUATORS AT EXISTING DOORS. SEE PLANS AND ELEVATIONS.
4. GC TO VERIFY EXISTING DOOR DIMENSIONS. NEW DOORS TO MATCH EXISTING SIZES.
DOOR HARDWARE NOTES
SEE PARTITION PLAN FOR WALL
TYPES
SCHEDULED DOOR
S
S
HOLLOW METAL FRAME - JAMB
PROVIDE DOUBLE
STUDS AT JAMBS TYP.
ROOM SIDE
PUBLIC SIDE
SEE PARTITION PLAN FOR WALL
TYPES
HOLLOW METAL FRAME - HEAD
SCHEDULED DOOR
JAMB BEYOND
SS
PUBLIC SIDE ROOM SIDE
REFER TO RCP FOR CEILING
TYPE
ANGLE BRACING ABOVE JAMB
SIDE
DOOR - REFER TO DOOR
SCHEDULE
GUIDES BEYOND
SEE PARTITION PLAN
ALUMINUM PKT. DR. FRAME -
HEAD. POCKET DOOR HEAD
ASSEMBLY
TYP.
METAL FRAMING
BRACED TO STRUCTURE
ABOVE
POCKET DOOR TRACK
SEE DOOR HARDWARE
SCHEDULE
FINISHED FLOOR
/2
BUILT UP HEADER
/4
M
A X
ANGLE SUPPORTS ABOVE
LATCH SIDE; ABOVE CEILING
SEE PARTITION PLAN
DOOR - REFER TO DOOR
SCHEDULE
PROVIDE DOUBLE STUDS
ALUMINUM POCKET DOOR
FRAME - JAMB
1 1/2"
CONTINUOUS BLOCKING
SCHEDULED SHAFT WALL
ASSEMBLY
/2
HOISTWAY ENTRY SILL
BY ELEVATOR MFR.
HOISTWAY ENTRY DOOR
BY ELEVATOR MFR.
HOISTWAY ENTRY FRAME JAMB
BY ELEVATOR MFR.
HOISTWAY
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET DRAWING NO.
PMIS SHEET
OF
NO.
99B
LOWE 475
187375
A13
DOOR TYPES, FRAME
TYPES & DETAILS
NPS LOWE TOILETS
PITRE
PITRE
HICKS
05/18/2023
DOOR SCHEDULE
DOOR
NO. From Room: Name
DOOR FRAME DETAIL
HDW
SET
FIRE
RTG
SECURITY
NOTES COMMENTSWTH HT THK TYPE MATL FIN TYPE MATL FIN
Head
Detail Jamb Detail
BCH 100 FAMILY RESTROOM 3'-0" 6'-8" 1 3/4" LV WD CLR HM1 HM PTD 2/A-13 1/A-13 -
BCH 101 UNISEX TOILET 3'-0" 6'-8" 1 3/4" LV WD CLR HM1 HM PTD 2/A-13 1/A-13 -
BCH 102 UNISEX TOILET 3'-0" 6'-8" 1 3/4" LV WD CLR HM1 HM PTD 2/A-13 1/A-13 -
BCH 103 UNISEX TOILET 3'-0" 6'-8" 1 3/4" LV WD CLR HM1 HM PTD 2/A-13 1/A-13 -
BCH 104 UNISEX TOILET 3'-0" 6'-8" 1 3/4" LV WD CLR HM1 HM PTD 2/A-13 1/A-13 -
BCH 105 UNISEX TOILET 3'-0" 6'-8" 1 3/4" LV WD CLR HM1 HM PTD 2/A-13 1/A-13 -
BCH 106 STORAGE CLOSET 2'-6" 6'-8" 1 3/4" F WD CLR HM1 HM PTD 2/A-13 1/A-13 -
BCH 107 MECHANICAL 3'-0" 7'-0" 1 3/4" F WD CLR HM1 HM PTD 2/A-13 1/A-13 45MIN
MCC 113 MEN'S TOILET 3'-0" 7'-0" 1 3/4" LV WD PTD ETR FRAME - PTD - - - ACUATED DOOR OPENER
MCC 114 WOMEN'S TOILET 3'-0" 7'-0" 1 3/4" LV WD PTD ETR FRAME - PTD - - - ACUATED DOOR OPENER
MCC 218 MEN'S TOILET 3'-0" 7'-0" 1 3/4" LV WD PTD ETR FRAME - PTD - - - ACUATED DOOR OPENER
MCC 219 WOMEN'S TOILET 3'-0" 7'-0" 1 3/4" LV WD PTD ETR FRAME - PTD - - - ACUATED DOOR OPENER
VC 005 UNISEX TOILET 3'-0" 7'-0" 1 3/4" SP WD PTD AL1 AL 4/A-13 3/A-13 - SLIDING POCKET DOOR w/ ALUM FRAME
VC 007 MEN'S TOILET ROOM 3'-0" 7'-0" 1 3/4" LV WD PTD HM1 HM 2/A-13 1/A-13 -
VC 008 WOMEN'S TOILET ROOM 3'-0" 7'-0" 1 3/4" LV WD PTD HM1 HM 2/A-13 1/A-13 -
VC 008B WOMEN'S TOILET ROOM 3'-0" 7'-0" 1 3/4" SP WD PTD AL1 AL 4/A-13 3/A-13 - SLIDING POCKET DOOR w/ ALUM FRAME
VC 108 UTILITY CLOSET 3'-0" 7'-0" 1 3/4" LV WD PTD ETR FRAME - PTD - - -
VC 109 TOILET 3'-0" 7'-0" 1 3/4" LV WD PTD ETR FRAME - PTD - - -
VC 111 TOILET 3'-0" 7'-0" 1 3/4" SP WD PTD AL1 AL 4/A-13 3/A-13 - SLIDING POCKET DOOR w/ ALUM FRAME
A13
1 HM FRAME - DR JAMB @ GWB1
A13
2 HM FRAME - DR HEAD @ GWB1
A13
4 AL FRAME - DR HEAD @ POCKET
A13
3 AL FRAME - DR JAMB @ POCKET STRIKE
A13
5 HOISTWAY ENTRY JAMB @ SHAFT WALL
dlieb Rectangle
David Lieb Rectangle
David Lieb Rectangle
David Lieb Rectangle
David Lieb Callout
HM1
David Lieb Line
David Lieb Line
LOCK
ACCESSIBLE URINAL STD URINALACCESSIBLE WC
LAVATORY
T O
P O
F S
E A
T
M A
X
3'-6" 1'-6"
" MAX
1'-0"
3'-6"
3'-6"
MAX
6"
'-0
'-5
M
A X
'-8
M
A X
T O
R
IM
O F
S
IN
K
'-1
M A
X
M
IN
8" MIN
M A
X A
L L S
T A
L L S
C O
A T
H O
O K
'-1
B O
T O
F R
E F
L E
C T
IV
E
S U
R F
A C
E
'-4
M
A X
RIM EXTENDS 14" MIN
FROM WALL
WALL MOUNTED ACCESSORIES
M A
X A
T C
O U
N T
E R
M A
X T
O B
O T
T O
M O
F
R E
F L E
C T
IV
E
S U
R F
A C
E
T O
O P
E R
A B
L E
P A
R T
30" MIN
17" MIN
MAX
6"
M
IN
AC-2
AC-4
AC-11
AC-13
AC-16
AC-11
AC-6
AC-17
AC-9
AC-10 AC-12
AC-16
TOILET ROOM FIXTURE & ACCESSORY MOUNTING LOCATIONS
AC-12
ACCESSIBLE WC
EQ A EQ A EQ B EQ B
AC-12
'-0
LOCK
STANDARD WC
T O
P O
F S
E A
T
" 4
M A
X A
L L S
T A
L L S
C O
A T
H O
O K
'-0
AC-2
AC-4
AC-13
AC-16
EQ EQ
STANDARD WC
T O
S P
O U
T
'-0
M
A X
'-6
DRINKING FOUNTAINS
M
IN
AC-1
'-6
3'-5"
'-0
2'-2"
M A
X
3'-6" MIN.
A D
JU
S
T A
B L E
H E
IG
H
T
AC-18
M A
X
2'-2"
AC-2
W H
E N
O P
E N
'-1
A F
F
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET DRAWING NO.
PMIS SHEET
OF
NO.
99B
LOWE 475
187375
A14
INTERIOR FINISHES,
ACCESSORY, FIXTURE
NPS LOWE TOILETS
PITRE
PITRE
HICKS
05/18/2023
ACCESSORIES SCHEDULE
TYPE
MARK MFR MODEL DESCRIPTION COMMENTS
AC-1 BOBRICK B-5193 SOLID PHENOLIC FOLDING SHOWER/DRESSING AREA SEAT
AC-2 BOBRICK B-2892 SURFACE MOUNTED TWIN JUMBO-ROLL TOILET TISSUE DISPENSER
AC-3 BOBRICK B-2890 SURFACE MOUNTED SINGLE JUMBO-ROLL TOILET TISSUE DISPENSER
AC-4 BOBRICK B-35303 RECESSED SANITARY NAPKIN DISPOSAL
AC-5 BOBRICK B-35139 SURFACE MOUNTED SANITARY NAPKIN DISPOSAL
AC-6 BOBRICK B-39747 RECESSED AUTOMATIC ROLL PAPER TOWEL DISPENSER AND WASTE RECEPTACLE
AC-7 BOBRICK B-3979 SURFACE MOUNTED AUTOMATIC ROLL PAPER TOWEL DISPENSER AND WASTE RECEPTACLE
AC-9 KOALA KARE KB310-SSWM BABY CHANGING STATION - SURFACE MOUNT
AC-10 KOALA KARE KB3000-AHL ADJUSTABLE HEIGHT CHANGING STATION
AC-11 AMERICAN SPECIALTIES INC 3700 GRAB BAR w/ SNAP-ON FLANGE COVERS
AC-12 BOBRICK B-1556 FRAMELESS STAINLESS STEEL MIRROR
AC-13 BOBRICK B-233 STAINLESS STEEL CLOTHES HOOK
AC-16 BRADLEY SERIES 400 SENTINEL TOILET PARTITIONS AND URINAL SCREENS
AC-17 KOALA KARE KB311-SSWM BABY CHANGING STATION - SURFACE MOUNT Available Colors: Grey with Stainless Steel
AC-18 BOBRICK B-2112 SURFACE MOUNT SOAP DISPENSER
ACT-1 TOILET ROOM CEILINGS SQUARE LAY-IN TILE ARMSTRONG DUNE TEGULAR 1774 24x24 CLASS A
CEILINGS
TL-1 WET WALLS CERAMIC TILE CREATIVE MATERIALS RAIN (COLOR AND FINISH TBD) 3x12 BULLNOSE EDGE
PT-1 WALL PAINT COLOR PAINT COLORS - TBD
WALLS
RSF-1 FLOORS RESINOUS FLOORING DUR-A-FLEX HYBRI-FLEX EQ INTEGRAL BASE
COLOR - TBD
FLOORING
TYPE MARK LOCATION DESCRIPTION MANUFACTURER PRODUCT SIZE CLASS FLAME SPREAD SMOKE DEVELOPED CONTACT COMMENTS
FINISH SCHEDULE
A14
1 TOILET ROOM FIXTURE & ACCESSORY MOUNTING LOCATIONS
GENERAL NOTES:
1. KEYED LOCATIONS ARE TO BE FOUND ON SHEETS A8, A9, A10 & A11
SHEET
OF
dlieb Rectangle dlieb Rectangle dlieb Callout
GRAB BAR AT 36" AFF MAX
1.5" SPACE BETWEEN BOTTOM OF GRAB BAR TO TOP OF ACCESSORY/DISPENSER
36" - 1.25" - 2" = 32.75" AFF TOP OF TP AND SN DISPENSERS.
TP (RED) EDGE OF TOILET; 1" SPACE BETWEEN, TO SN (BLUE)
dlieb Line dlieb Callout
BLUE - SANITARY NAPKIN DISPENSER
dlieb
RED - TP DISPENSER, B2890
FROM FACE OF GYP/CMU
2'-0" COUNTER DEPTH
1/4" GROUT
LINE
7/8"
ACTUAL TILE DEMNSION
1'-0"
M
IN
F
R O
M S
ID
E
W A
L L
/2
MIRROR
Level 1
0' - 0"
A15
'-9
CERAMIC TILE w/ BULLNOSE EDGE, TYP
FRAMELESS MIRROR
6" CERAMIC TILE BACKSPLASH. ALIGN
WITH GROUT LINE
INTEGRATED SINK. SEE
PLUMBING DWGS
CONT SEALANT
CERAMIC TILE
RESINOUS FLOORING AND
4" INTEGRATED BASE
'-4
M A
X
'-1
IN-WALL BLOCKING
AS NECESSARY
LIGHT FIXTURE. SEE ELEC
/2
ACOUSTICAL CEILING SYSTEM
ST. STEEL EDGE
1'-6"
/2
FLOOR ABOVE
DIAGONAL BRACING @ 4' O.C.
M
IN
A
B O
V E
F
IN
IS
H
E D
F L
O O
R
WALL FAUCET
7" 7"
LINEAR SLOT DIFFUSER
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET DRAWING NO.
PMIS SHEET
OF
NO.
99B
LOWE 475
187375
A15
RESTROOM DETAILS
NPS LOWE TOILETS
Designer
Author
Checker
05/18/2023
A15
1 COUTERTOP EDGE DETAIL
A15
2 SECTION AT LAVATORY
David Lieb Rectangle
David Lieb Line
David Lieb Line
David Lieb Line
David Lieb
EXTEND ACT FULL BATHROOM, LIGHTS AND DIFFUSER TO BE RECESSED INTO ACT
V
MPV
T
PS
F
P
P
F
FS
PP
GAS PIPING
FLOW SWITCH
EQUIPMENT TAG
AUTOMATIC AIR VENT
VENT PIPING
MULTIPURPOSE VALVE
PRESSURE SWITCH
THERMOMETER
HOT WATER PIPING
POINT OF CONNECTION TO EXISTING
DUCT STATIC PRESSURE SENSOR
VARIABLE AIR VOLUME BOXCOLD WATER PIPING
PRESSURE REGULATING VALVE
UNION
CIRCUIT BALANCE VALVE
SWING CHECK VALVE
BALL VALVE
BUTTERFLY VALVE
PRESSURE GAUGE W/PETCOCK
THERMOSTAT
GATE VALVE
MANUAL AIR VENT
HOT WATER RETURN PIPING
CHILLED WATER SUPPLY PIPING
HOT WATER SUPPLY PIPING
CHILLED WATER RETURN PIPING
HWS
HWR
CHWS
CHWR
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
CWR
CWS
PIPE DROP
PIPE RISER
PIPE TEE - DOWN
PIPE TEE - UP
PIPE CONNECTION
PIPE BREAK - TO CONTINUE
DIRECTION OF FLOW
EXISTING RECTANGULAR DUCT RUN W/ SIZE
DESIGNATION
EXISTING CIRCULAR DUCT RUN W/ SIZE DESIGNATION
DEMOLITION RECTANGULAR DUCT RUN W/ SIZE
DESIGNATION
DEMOLITION CIRCULAR DUCT RUN W/ SIZE
DESIGNATION
NEW RECTANGULAR DUCT RUN W/ SIZE DESIGNATION
NEW CIRCULAR DUCT RUN W/ SIZE DESIGNATION
NEW RECTANGULAR DUCT - UP
NEW CIRCULAR DUCT RUN - UP
NEW RECTANGULAR DUCT - DOWN
NEW CIRCULAR DUCT RUN - DOWN
EXISTING FLEX DUCT RUN W/ SIZE DESIGNATION
DEMOLITION FLEX DUCT RUN W/ SIZE DESIGNATION
NEW FLEX DUCT RUN W/ SIZE DESIGNATION
ACOUSTICALLY LINED DUCT RUN
ELEVATION CHANGE IN DUCTWORK - UP
RECTANGULAR TO RECTANGULAR DUCTWORK TRANSITION
RECTANGULAR TO CIRCULAR DUCTWORK TRANSITION
RECTANGULAR TO RECTANGULAR DUCTWORK TRANSITION
ELEVATION CHANGE IN DUCTWORK - DOWN
DUCTWORK BREAK - TO CONTINUE
RG, RR
EG, ER
SD, SR, SG
SD, SR, SG
SD, SR, SG
SD, SR, SG
SD, SR, SG
DIFFUSER, REGISTER OR GRILLE TAG, WITH CFM
AIRFLOW
NOTE CALL OUT1
COMBINATION FIRE SMOKE DAMPER
FIRE DAMPER
MANUAL VOLUME DAMPER
HUMIDIFIER
PIPE CAP
PIPE GUIDE
PIPE ANCHOR
CW
HW
V
G
REHEAT HOT WATER RETURN PIPING
REHEAT HOT WATER SUPPLY PIPINGRHWS
RHWR
REVISION TAG
REVISION CLOUD
DUCT SIZE12∅, 12x12
AD
AFF
AFG
AP
AS
ATC
BC
BFP
BOD
BTU
BTUH
C
C&HW
CAP
CC
CD
CFM
COL
CV
DB
DDC
DIA
DN
DO
DWG OR DWGS
E, EX OR (E)
EA
EAT
EC
ECU
EF
EL
EMS
ERV
ESP
ET
ETR
EWT
EXH
FA
FC
FCU
FD
FLA
FLR
FPI
FPM
FSD
FT
FTR
GAL
GC
GE
GPM
GV
HC
HP
HVAC
HW
ID
IH
IN
KW
L
LAT
LWT
MBH
MD
MECH
MTD
N.C. OR NC
N.O. OR NO
NIC
NOM
NTS
O.A. OR OA
OAT
OD
OED
PC
PD
PSI
PRV
RA
REF
RF
RHWR
RHWS
RM
RV
SA
SAT
SF
SP
SPD
SPEC
SS
TOD
TSTAT
TYP
U.G.
U.S.
UC
V
VAV
VB
VFD
VTR
W W/
WB
DUCT ACCESS DOOR
ABOVE FINISHED FLOOR
ABOVE FINISH GRADE
ACCESS PANEL
AIR SEPARATOR
AUTOMATIC TEMPERATURE CONTROL
BLOWER COIL
BACK FLOW PREVENTER
BOTTOM OF DUCT
BRITISH THERMAL UNIT
BRITISH THERMAL UNIT PER HOUR
CONVECTOR
COLD & HOT WATER
CAPACITY
COOLING COIL
CEILING DIFFUSER
CUBIC FEET PER MINUTE
COLUMN
CONTROL VALVE
DRY BULB TEMPERATURE
DIRECT DIGITAL CONTROL
DIAMETER
DOWN
DIGITAL OUTPUT
DRAWING OR DRAWINGS
EXISTING
EXHAUST AIR
ENTERING AIR TEMPERATURE
ELECTRICAL CONTRACTOR
EVAPORATIVE CONDENSING UNIT
EXHAUST FAN
EXPANSION LOOP
ENERGY MANAGEMENT SYSTEM
ENERGY RECOVERY VENTILATOR
EXTERNAL STATIC PRESSURE
EXPANSION TANK
EXISTING TO REMAIN
ENTERING WATER TEMPERATURE
EXHAUST
FREE AREA
FLEXIBLE CONNECTION
FAN COIL UNIT
FIRE DAMPER
FULL LOAD AMPS
FLOOR
FINS PER INCH
FEET PER MINUTE
COMBINATION FIRE AND SMOKE DAMPER
FEET
FIN TUBE RADIATION
GALLONS
GENERAL CONTRACTOR
GENERAL EXHAUST
GALLONS PER MINUTE
GATE VALVE
HEATING COIL
HORSE POWER
HEATING, VENTILATION AND AIR COND.
HOT WATER
INSIDE DIAMETER
INTAKE HOOD
INCHES
KILOWATTS
LOUVER
LEAVING AIR TEMPERATURE
LEAVING WATER TEMPERATURE
THOUSANDS OF B.T.U.'S PER HOUR
MOTORIZED DAMPER
MECHANICAL
MOUNTED
NORMALLY CLOSED
NORMALLY OPEN
NOT IN CONTRACT
NOMINAL
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
OUTSIDE DIAMETER
OPEN ENDED DUCT
PLUMBING CONTRACTOR
PRESSURE DROP
POUNDS PER SQUARE INCH
PRESSURE REDUCING VALVE
RETURN AIR
RETURN EXHAUST FAN
RETURN FAN
REHEAT WATER RETURN
REHEAT WATER SUPPLY
ROOM
RELIEF VALVE
SUPPLY AIR
SUPPLY AIR TEMPERATURE
SQUARE FEET
STATIC PRESSURE
SPEED
SPECIFICATION
STAINLESS STEEL
TOP OF DUCT
THERMOSTAT
TYPICAL
UNDER GRADE
UNDER SLAB
UNDERCUT DOOR
VENT
VARIABLE AIR VOLUME
VACUUM BREAKER
VARIABLE FREQUENCY DRIVE
VENT THROUGH ROOF
WASTE
WITH
WET BULB TEMPERATURE (°F)
HOT WATER RETURN PIPINGHWR
GLOBE VALVE
FLANGE
STRAINER W/DRAIN VALVE AND CAP
PRESSURE PORT ("PETE'S PLUG")
CHEMICAL SUPPLY PIPESCHEM
SANITARY DRAIN ABOVE FLOOR OR GRADESAN
HIGH-TEMPERATURE HOT WATER RETURNHTWR
MEDIUM-TEMPERATURE HOT WATER RETURNMTWR
FUEL OIL TANK VENTFOV
HIGH-TEMPERATURE HOT WATER SUPPLYHTWS
MEDIUM-TEMPERATURE HOT WATER SUPPLYMTWS
FUEL OIL RETURNFOR
FUEL OIL SUCTIONFOS
FUEL OIL GAGEFOG
FUEL OIL DISCHARGEFOD
BOILER BLOWDOWNBBD
HIGH-PRESSURE CONDENSATEHPC
PUMPED CONDENSATEPC
MAKE UP WATERMUW
A.C. CONDENSATE DRAIND
REFRIGERANT HOT GASRHG
RL
RS
GLYCOL RETURNGR
REFRIGERANT LIQUID
REFRIGERANT SUCTION
GLYCOL SUPPLYGS
HWS
HWR
CHWS
CHWR
CWR
CWS
RHWS
RHWR
CHEM
SAN
HTWR
MTWR
FOV
HTWS
MTWS
FOR
FOS
FOG
FOD
BBD
HPC
PC
MUW
D
RHG
RL
RS
GR
GS
BLV
BFV
SCV
CBV
ACV
ACV
GV
GLV
MPV
PRV
T
FLG
RSV
PGV
RPBP
RELIEF OR SAFETY VALVE
PLUG VALVE
REDUCED PRESSURE BACKFLOW PREVENTER
S-1
VAV
RETURN AIR GRILLE, REGISTER
EXHAUST AIR GRILLE, REGISTER
SUPPLY AIR 4 WAY DIFFUSER, REGISTER, GRILLE
SUPPLY AIR 3 WAY DIFFUSER, REGISTER, GRILLE
SUPPLY AIR 2 WAY DIFFUSER, REGISTER, GRILLE
SUPPLY AIR 2 WAY DIFFUSER, REGISTER, GRILLE
SUPPLY AIR 1 WAY DIFFUSER, REGISTER, GRILLE
ANCHOR
GUIDE
U
1. ALL HVAC GENERAL NOTES, SYMBOLS LISTS & DETAILS ARE TO BE
CONSIDERED AS APPLICABLE TO ALL HVAC DRAWINGS FOR THIS
PROJECT.
2. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND EXACT LOCATIONS
AND ARRANGEMENTS OF EXISTING/NEW EQUIPMENT, DUCTWORK,
PIPING AND OTHER COMPONENTS SHALL BE DETERMINED IN THE FIELD
WITH DUE CONSIDERATION OF STRUCTURAL, ELECTRICAL AND
ARCHITECTURAL SYSTEMS. EXISTING STRUCTURAL SYSTEMS SHALL
NOT BE MODIFIED WITHOUT THE EXPRESS PERMISSION OF THE
ENGINEER.
3. THE PROJECT SHALL BE PHASED IN ACCORDANCE WITH THE
CONTRACTOR'S APPROVED PHASING PLAN. THE CONTRACTOR SHALL
OBTAIN APPROVAL FROM THE OWNER FOR THE SEQUENCING AND
TIMING OF OPERATIONS PRIOR TO COMMENCING WORK. SEE
SPECIFICATIONS.
4. CONTRACTOR IS TO MAINTAIN SERVICE TO ROOMS OUTSIDE THE
PROJECT SCOPE OF WORK AND PHASING SCHEDULE. IF INTERRUPTION
OF SERVICE IS REQUIRED, COORDINATE SHUTDOWN WITH THE OWNER.
NOTIFY THE OWNER A MINIMUM OF 96 HOURS PRIOR TO SHUTDOWN.
5. CARE SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT EXISTING
SYSTEMS AND SURFACES TO REMAIN. RESTORE DAMAGED AREAS THAT
ARE BEYOND THE SCOPE OF THIS CONTRACT TO THEIR ORIGINAL
CONDITION.
6. WHERE INDICATED ON THE DRAWINGS, REMOVE OR RELOCATE
EXISTING COMPONENTS AS REQUIRED TO ACCOMMODATE THE NEW
WORK. REMOVALS SHALL INCLUDE ALL ASSOCIATED OFF-SITE DISPOSAL
COSTS.
7. COORDINATE REMOVALS AND RELOCATIONS INCLUDING SELECTIVE
CUTTING AND PENETRATIONS WITH ARCHITECTURAL, MECHANICAL,
STRUCTURAL AND ELECTRICAL CONTRACTORS.
8. ALL PARTITIONS ARE FULL HEIGHT AND REQUIRE UTILITIES
PENETRATIONS TO BE SEALED. UTILITIES SHOWN FOR CLARITY THAT
MAY RUN PARALLEL TO WALL PARTITIONS WILL REQUIRE LOCATING IN
THE FIELD TO MINIMIZE CONFLICT WITH PARTITIONS.
9. COORDINATE THE LOCATIONS OF ALL WALL MOUNTED TEMPERATURE
SENSORS WITH FINAL EQUIPMENT/FURNITURE LAYOUT.
10. PROVIDE SEISMIC RESTRAINTS PER SPECIFICATION 130541.
11. MANUFACTURERS NAME & MODEL NUMBER ARE USED FOR DESCRIPTIVE
PURPOSES ONLY & ARE INTENDED TO INDICATE THE STANDARD OF
MATERIAL OR ARTICLES REQUIRED.
12. INSTALL EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS AND GOOD PRACTICE NORMAL TO THE TRADE.
INSTALLATION SHALL INCLUDE PROVISIONS FOR ACCESS TO NORMAL
MAINTENANCE ITEMS SUCH AS BELTS, BEARINGS, FILTERS AND
MOTORS. PROVIDE ADEQUATE STRUCTURAL SUPPORTS AND SECURE
MOUNTING METHODS WITH PROVISIONS FOR VIBRATION ISOLATION AND
EXPANSION WHERE REQUIRED.
13. PROVIDE VOLUME DAMPERS AT EACH BRANCH FROM MAIN DUCTWORK
AND DUCT RUNNOUTS TO AN INDIVIDUAL REGISTER OR DIFFUSER IN
SUPPLY, RETURN AND EXHAUST DUCTS IRRESPECTIVE OF WHETHER OR
NOT A DAMPER IS INDICATED ON THE PLANS.
14. DIFFUSER SIZES INDICATED ARE NECK SIZES. REGISTERS & GRILLES
ARE INDICATED AS NOMINAL SIZES.
15. PERFORM ALL TESTS BEFORE INSULATING. PERFORM ALL PRESSURE
TESTING AND CLEAN DUCTWORK/PIPING PRIOR TO INSULATION.
16. PIPING AND DUCTWORK SHALL BE CONCEALED UNLESS OTHERWISE
NOTED.
17. INSTALLATION SHALL PERMIT ACCESSIBILITY FOR SERVICE AND/OR
REPLACEMENT OF EQUIPMENT PROVIDED. PROVIDE ACCESS PANELS TO
GAIN ACCESS TO SYSTEMS COMPONENTS THAT REQUIRE MAINTENANCE
ACCORDING TO MANUFACTURER'S LITERATURE.
18. PROVIDE DUCTWORK WITH OFFSETS AND TRANSITIONS AS REQUIRED
TO FIT UNDER STRUCTURAL STEEL OR OTHER OBSTRUCTIONS. FLAT
OVAL OR ROUND SIZES MAY BE USED INTERCHANGEABLY BY THE
CONTRACTOR. MAINTAIN DUCT CROSS SECTIONAL AREA. CHANGES
SHALL BE ONLY IN ACCORDANCE WITH APPROVED SHOP DRAWINGS OR
WRITTEN PERMISSION OF THE PROJECT ENGINEER.
19. PROVIDE CLAMPS, OFFSETS, EXPANSION JOINTS, ANCHORS & GUIDES
AS NECESSARY TO PREVENT UNDUE STRAIN ON PIPING.
20. SEE DETAILS & PIPING DIAGRAMS FOR ADDITIONAL VALVES & FITTINGS
NECESSARY FOR COMPLETE PIPING SYSTEM.
21. MECHANICAL CONTRACTOR TO COORDINATE ALL WORK WITH OTHER
BUILDING TRADES. SOME RELOCATION OF EXISTING UTILITIES MAY BE
NECESSARY TO ACCOMMODATE INSTALLATION OF NEW EQUIPMENT OR
DUCTWORK.
22. PROVIDE FIRE OR FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS
& WHERE REQUIRED BY APPLICABLE CODES FOR DUCTS & OPENINGS
THROUGH FLOORS, FIRE WALLS & FIRE PARTITIONS. DAMPERS SHALL BE
ENCLOSED IN #14 GAUGE STEEL SLEEVE. PROVIDE ACCESS DOORS
LOCATED SO THAT FUSIBLE LINK & OTHER DAMPER COMPONENTS MAY
BE INSPECTED REPLACED AND/OR SERVICED.
23. SEE SPECIFICATIONS FOR OTHER REQUIREMENTS.
24. AT THE END OF EACH WORKING DAY, THE CONSTRUCTION SITE SHALL
BE LEFT IN A CLEAN AND NEAT CONDITION.
25. FILL AND PATCH ALL OPENINGS IN WALLS WHERE CONDUITS, PIPES,
DUCTS ETC. ARE OR HAVE BEEN REMOVED WITH UL LISTED FIRE
ASSEMBLY APPROVED BY THE ARCHITECT. MAINTAIN 2 HR FIRE RATING
WHERE APPLICABLE.
26. TIE-IN POINT LOCATIONS ARE APPROXIMATE. CONTRACTOR SHALL
DETERMINE EXACT LOCATIONS IN THE FIELD BASED ON EXISTING
CONDITIONS.
27. EQUIPMENT ARRANGEMENT, DUCTWORK SIZES, PENETRATIONS AND
DETAILS ARE BASED ON EQUIPMENT SCHEDULED. CONTRACTOR SHALL
ADJUST SIZES AND ROUTING AS REQUIRED TO ACCOMMODATE ACTUAL
EQUIPMENT INSTALLED.
28. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HANDLING, STORAGE
AND SETTING OF ALL EQUIPMENT AND MATERIAL. CRANES, LIFTS,
HOISTS, AND SCAFFOLDING OF ALL EQUIPMENT SHALL BE EMPLOYED AS
REQUIRED TO COMPLETE THE INSTALLATION.
SMOKE DAMPER
3-WAY AUTOMATIC CONTROL
VALVE (MIXING PATTERN)
2-WAY AUTOMATIC CONTROL VALVE
SHADED DUCTWORK SHALL BE 16 GAUGE SHEETMETAL10x16
ROOF EXHAUST - EXISTING
ROOF EXHAUST - REMOVED
ROOF EXHAUST - NEW
EXPANSION JOINT
PIPE SIZE12"
G
PIPE SLOPE
PIPE SIZE, GANG
12"S UP
14"DN
1-1/2"
F&T
FLOAT & THERMOSTATIC TRAP
SYMBOLS DESCRIPTIONSABBREVIATIONS DESCRIPTIONSSYMBOLSSYMBOLS DESCRIPTIONSDESCRIPTIONSABBREVIATIONS SYMBOLS DESCRIPTIONS
SYMBOLS DESCRIPTIONSABBREVIATIONS
TITLENUMBER
DIFFUSER SYMBOLS
MECHANICAL LIST
DUCTWORK SYMBOLSGENERAL SYMBOLSPIPING SYMBOLSGENERAL ABBREVIATIONSHVAC GENERAL NOTES
POINT OF DISCONNECTION FROM EXISTING
V
S
T REMOTE TEMPERATURE AND HUMIDITY DISPLAYH
M ROOM TEMPERATURE, HUMIDITY AND DIFFERENTIAL
PRESSURE ALARM/DISPLAY MONITOR
M MANUAL PURIFIER (P-1) ACTIVATION SWITCH
NOTES
M1 MECHANICAL GENERAL NOTES AND LEGNEDS
M2 MECHANICAL DEMOLITION PLAN
M3 MECHANICAL MOGAN DEMOLITION PLAN
M4 MECHANICAL NEW PLAN
M5 MECHANICAL MOGAN NEW PLAN
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET DRAWING NO.
PKG SHEET
OF
NO.M1
MECHANICAL GENERAL
NOTES AND LEGEND
NPS LOWE TOILETS
PIIK
RISINGER
DESPOTOVICH
05/18/2023
99B
NOTE: NOT ALL SYMBOLS AND
ABBREVIATIONS ARE USED
3 3
MEN'S
TOILET
MCC 218
WOMEN'S
TOILET
MCC 219
2 2
MEN'S
TOILET
MCC 113
WOMEN'S
TOILET
MCC 114
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET DRAWING NO.
PKG SHEET
OF
NO.M3
MECHANICAL MOGAN
DEMOLITION PLAN
NPS LOWE TOILETS
Designer
Author
DESPOTOVICH
05/18/2023
99B
1/4" = 1'-0"M3
2 MOGAN CULTURAL CENTER - 2ND FLOOR MECH DEMO
1/4" = 1'-0"M3
1 MOGAN CULTURAL CENTER - 1ST FLOOR MECH DEMO
KEYNOTES
REMOVE EXISTING EXHAUST FAN1
2 REMOVE EXISTING EXHAUST GRILLE
3 EXISTING TO REMAIN CABINET UNIT HEATER
0' 2' 4' 8'
GENERAL NOTE:
LEAVE EXISITNG DUCTWORK IN PLACE TO BE REUSED,
EXCEPT WHERE NOTED TO BE REMOVED
FE
BC
FCU
4"⌀
EF 75 CFM MIN
(TYP OF 6)
10"X3-1/2" DOWN. CUT HOLE IN FLOOR.
TERMINATE OPEN END DUCT WITH SS WMS (TYP)
SUPPLY DIFFUSER
BOTTOM OF DUCT
150 CFM (TYP OF 6)
12"X12" TRANSFER
DUCT (VIF)
42"X24" GRILLE
(VIF)
4"⌀
4"⌀
EF-4 IN-LINE EF
50 CFM MIN.
4"⌀ 4"⌀ 4"⌀ 4"⌀
2 2
MECHANICAL
BCH 107
LOBBY
STORAGE
CLOSET
BCH 106
UNISEX
TOILET
BCH 105
UNISEX
TOILET
BCH 104
UNISEX
TOILET
BCH 103
UNISEX
TOILET
BCH 102
UNISEX
TOILET
BCH 101
FAMILY
RESTROOM
BCH 100
EF3 EF3 EF3EF3EF3EF3
16X8(E) 28X8(E)
22X8(E)
NEW EXHAUST
GRILLE
PLENUM
T
PROVIDE OFFSET UP IN DUCTWORK. (TYP) SEE KEYNOTE 2
MEN'S
TOILET
ROOM
VC 007
WOMEN'S
TOILET
ROOM
VC 008
UNISEX
TOILET
VC 005
TOILET
VC 111
UTILITY
CLOSET
VC 108
TOILET
VC 109
EF2
EXHAUST DUCT
(SEE PLAN FOR SIZE)
EXHAUST FAN
OPTION CEILING CEILING GRILLE
EXHAUST FAN DETAIL
WALL SUPPORT FROM
STRUCTURE ABOVE
SUPPORT ANGLE
TYPE B
8'-0" O.C.
4'-0" O.C.
1 1/2"x1 1/2"x1/8"3/8"
USE 1"x1/8"
25" TO 36"
UP TO 24"
(OR WELD STUD)
BLIND RIVETS
TYPE
A
DUCT WIDTH
HANGER RODS
SOLID BANDS
NON-GMP SYSTEMS: ALL FAN COIL UNITS
NOTE: ALL INSULATED DUCTWORK SHALL HAVE THERMAL BREAK AT EACH
DUCT SUPPORT.
ROD
DIAMETER
TYPE
SUPPORT ANGLE MAX
SPACING
NON-GMP
SYSTEMS
B
A
INSULATION
1 1/2"x1 1/2"x1/8"
DUCT HANGER DETAIL AND SCHEDULE
COLD PIPE
(VAPOR BARRIER)
WITH INSULATION
PIPE
WITHOUT INSULATION
HOT PIPE
(NO VAPOR BARRIER)
WITH INSULATION
INSULATION O.D.
CLEVIS HANGER
HANGER ROD
RIGID INSULATION
SHEETMETAL SHIELD
PIPE
NUT
PIPE
PIPE O.D.
CLEVIS HANGER
HANGER ROD (TYPICAL)
SHEETMETAL SHIELD
RIGID INSULATION
NUTNUT
PIPE HANGER DETAIL - CLEVIS TYPE
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET DRAWING NO.
PKG SHEET
OF
NO.M4
MECHANICAL NEW PLAN
NPS LOWE TOILETS
PIIK
RISINGER
DESPOTOVICH
05/18/2023
99B
1/4" = 1'-0"M4
2 BOOTT COUNTING HOUSE - LEVEL 1 MECH1/4" = 1'-0"M4
4 VISITOR CENTER - GROUND FLOOR MECH
1/4" = 1'-0"M4
5 VISITOR CENTER - 1ST FLOOR MECH
KEYNOTES
PROVIDE NEW LINEAR SLOT DIFFUSER. CONNECT TO
EXISTING SUPPLY DUCT
PROVIDE NEW EXHAUST FAN. OFFSET BRANCH
CONNECTIONS, BULLHEAD CONFIGURATION NOT ALLOWED
PROVIDE NEW EXHAUST FAN. CONNECT TO EXISTING
EXHAUST AIR SYSTEM
REBALANCE FCU TO NEW DESIGN AIRFLOW
REFURBISH EXISTING EQUIPMENT. CLEAN
WASHABLE/REPLACE REPLACEABLE AIR FILTERS,
REPLACE BELTS, CLEAN COILS, GREASE BEARINGS
7 RE-INSTALL EXISTING THERMOSTAT AND WIRE TO EXISTING
FCU
5 ROUTE TRANSFER DUCTS ABOVE THE EXISTING SUPPLY,
ON EITHER SIDE OF EXISTING SPRINKLER PIPE. PROTECT
OPENING WITH WMS
8 PROVIDE NEW EXHAUST GRILLE. CONNECT TO EXISTING
EXHAUST SYSTEM
0' 2' 4' 8'
NOTES:
1. PROVIDE FLEXIBLE CONNECTIONS ON THE INLET AND OUTLET CONNECTIONS OF FAN RO DUCTWORK
2. PROVIDE 120VAC TO 24VDC TRANSFORMER
3. PROVIDE FACTORY MOUNTED NEMA-1 DISCONNECT SWITCH
4. UNIT SHALL OPERATE AS INDEXED BY WALL MOUNTED PROGRAMMABLE TIME-CLOCK DURING OCCUPIED HOURS
5. PROVIDE GRAVITY BACKDRAFT DAMPER
6. PROVIDE FACTORY VIBRATION ISOLATION KIT
1,2,3,4,5,6
EF 4 BOOTT/JANITOR 50 0.5 OCCUPANCY INLINE 2,083 0.05 .15 2,083 DIRECT 120 1.3 1 8 CAPTIVEAIRE DFA-100-CA 1,2,3,4,5,6
EF 3 BOOTT/RESTROOM 75 0.26 OCCUPANCY CEILING 900 0.01 .01 900 DIRECT 120 0.17 1 12 GREENHECK SP-A90 1,2,3,4,5,6
EF 2 VISITOR/RESTROOM 75 0.26 OCCUPANCY CEILING 900 0.01 .01 900 DIRECT 120 0.17 1 12 GREENHECK SP-A90 1,2,3,4,5,6
EF 1 MOGAN/RESTROOM 140 0.5 OCCUPANCY CEILING 648 0.11 .17 648 DIRECT 120 2.3 1 23 CAPTIVEAIRE CFA-200-CA 1,2,3,4,5,6
MARK #
BUILDING/AREA
SERVED
TYPE
SPEED
(RPM)
BHP HP
SPEED
(RPM)
DRIVE
TYPE
VOLTS MCA PHASE
UNIT IDENTIFICATION
AIRFLOW
(CFM)
ESP
(IN-WG)
CONTROL
FAN WHEEL FAN MOTOR ELECTRICAL
OPERATING
WEIGHT
(LBS.)
MANUFACTURER
MODEL
NUMBER
NOTES
EXHAUST FAN SCHEDULE
9 EXISTING BLOWER COIL (BC) AND EXISTING FAN COIL UNIT
(FCU)
David Lieb Line
David Lieb Line
David Lieb Line
3 3
MEN'S
TOILET
MCC 113
WOMEN'S
TOILET
MCC 114
EF1EF1
2 2
4 4
MEN'S
TOILET
MCC 218
WOMEN'S
TOILET
MCC 219
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET DRAWING NO.
PKG SHEET
OF
NO.M5
MECHANICAL MOGAN NEW
PLAN
NPS LOWE TOILETS
PIIK
RISINGER
DESPOTOVICH
05/18/2023
99B
1/4" = 1'-0"M5
1 MOGAN CULTURAL CENTER - 1ST FLOOR MECH
1/4" = 1'-0"M5
2 MOGAN CULTURAL CENTER - 2ND FLOOR MECH
KEYNOTES
PROVIDE NEW EXHAUST FAN1
2 COORDINATE FOR NEW LOUVERS IN NEW DOORS FOR 0.75
SQ.FT. SEE ARCH PLANS FOR COLOR/FINISH
3 PROVIDE NEW EXHAUST GRILLE. CONNECT TO EXISTING
DUCT. BALANCE TO 100 CFM MIN
4 EXISTING TO REMAIN CABINET UNIT HEATER. COORDINATE
WITH NEW CEILING
0' 2' 4' 8'
T
PS
F
P
MPV
FLOW SWITCH
AUTOMATIC AIR VENT
WATER HAMMER ARRESTOR
VENT PIPING
PRESSURE SWITCH
DOMESTIC HOT WATER PIPING
POINT OF CONNECTION TO EXISTING (TIE-IN POINT)
DOMESTIC COLD WATER PIPING
PRESSURE GAUGE W/PETCOCK
THERMOMETER W/IMMERSION WELL
MANUAL AIR VENT
DOMESTIC HOT WATER RECIRCULATION PIPINGDHWR
1. ALL PLUMBING GENERAL NOTES, SYMBOLS, LISTS AND DETAILS ARE TO BE
CONSIDERED AS APPLICABLE TO ALL PLUMBING DRAWINGS FOR THIS
PROJECT.
2. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND EXACT LOCATIONS
AND ARRANGEMENTS OF EXIST./NEW EQUIPMENT, DUCTWORK, PIPING
AND OTHER COMPONENTS SHALL BE DETERMINED IN THE FIELD WITH DUE
CONSIDERATION OF STRUCTURAL, ELECTRICAL AND ARCHITECTURAL
SYSTEMS. EXISTING STRUCTURAL SYSTEMS SHALL NOT BE MODIFIED
WITHOUT THE EXPRESS PERMISSION OF THE ENGINEER.
3. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE PROJECT ENGINEER
FOR THE SEQUENCING AND TIMING OF OPERATIONS PRIOR TO COMMENCING
WORK. SEE SPECIFICATIONS.
4. CONTRACTOR IS TO MAINTAIN SERVICE TO ROOMS OUTSIDE THE PROJECT
SCOPE OF WORK. IF INTERRUPTION OF SERVICE IS REQUIRED COORDINATE
SHUTDOWN WITH PROJECT ENGINEER.
5. CARE SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT EXISTING
SYSTEMS AND SURFACES TO REMAIN. RESTORE DAMAGED AREAS THAT ARE
BEYOND THE SCOPE OF THIS CONTRACT TO THEIR ORIGINAL CONDITION.
6. WHERE INDICATED ON THE DRAWINGS, REMOVE OR RELOCATE EXISTING
COMPONENTS AS REQUIRED TO ACCOMMODATE THE NEW WORK.
REMOVALS SHALL INCLUDE ALL ASSOCIATED OFF-SITE DISPOSAL COSTS.
7. COORDINATE REMOVALS AND RELOCATION'S INCLUDING SELECTIVE CUTTING
AND PENETRATIONS WITH ARCHITECTURAL, MECHANICAL, STRUCTURAL AND
ELECTRICAL CONTRACTORS.
8. MOST PARTITIONS ARE FULL HEIGHT AND REQUIRE UTILITIES PENETRATIONS
TO BE SEALED, SEE ARCHITECTURAL DWGS FOR PARTITION HEIGHTS.
DUCTWORK SHOWN FOR CLARITY THAT MAY RUN PARALLEL TO WALL
PARTITIONS WILL REQUIRE LOCATING IN THE FIELD TO MINIMIZE CONFLICT
WITH PARTITIONS.
9. FIELD VERIFY EXISTING EQUIPMENT AND PIPING PRIOR TO REMOVAL OR
REUSE. CONFIRM WITH PROJECT ENGINEER THAT ALL EQUIPMENT AND
PIPING DESIGNATED TO BE REMOVED IS NO LONGER IN SERVICE PRIOR
TO ITS REMOVAL. PROJECT ENGINEER SHALL HAVE FIRST RIGHT OF
REFUSAL ON ALL DEMO'D EQUIPMENT.
10. EXISTING EQUIPMENT AND PIPING TO REMAIN IN SERVICE SHALL BE
INSPECTED, REPORT INOPERABLE EQUIPMENT TO PROJECT ENGINEER.
11. ALL UNUSED (ABANDONED), PIPING AND EQUIPMENT INDICATED TO BE
REMOVED SHALL BE…