B08-Attachment_2-LOWE_Drawings_REV_2026_04_22.pdf

PDF 3 MB Posted

Attached to
Lowell National Historical Park; Rehabilitate Bath
Solicitation number
140P4326R0014
Issued by

About this file

This document is a complete set of construction drawings for the Lowell National Historical Park bathroom rehabilitation project. The project involves comprehensive renovation of restroom facilities across multiple buildings including the Visitor Center, Boott Counting House, and Mogan Cultural Center at various floor levels.

The scope of work encompasses demolition of existing fixtures, finishes, and systems followed by installation of new plumbing, mechanical, electrical, fire protection, and architectural components. Key deliverables include new water closets, lavatories, urinals, and integrated sink systems (primarily Sloan and Bradley brands); exhaust fans ranging from 50-140 CFM capacity with manual motor switches; LED lighting fixtures including recessed troffers, cove lights, and pendant-mounted units; new ceramic tile finishes with bullnose edges and grout lines; resinous flooring with 4-inch integrated bases; gypsum wall board partitions with various fire ratings (1-hour to 2-hour rated assemblies); and new fire protection sprinkler coverage with pendant and upright heads per NFPA-13 standards. The project includes coordination with multiple MEP (mechanical, electrical, plumbing) trades, phased construction sequencing, and strict attention to maintaining fire-smoke ratings on existing structures. Standard construction practices are specified throughout, including seismic restraints per specification 130541, manufacturer-recommended equipment installation, and comprehensive coordination with structural, architectural, and other building systems to minimize conflicts and ensure proper integration of all new work elements.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWING INDEX

DRAWING NAME

G1 COVER SHEET

A0 GENERAL NOTES & LEGENDS

A1 DEMO PLANS

A2 DEMO RCP

A3 MOGAN CULTURAL CENTER DEMO PLANS AND RCP

A4 FLOOR PLANS

A5 RCP PLANS

A6 FINISH PLANS

A7 MOGAN CULTURAL CENTER PLANS AND RCP

A8 INTERIOR ELEVATIONS - VISITOR CENTER - 1st FLOOR

A9 INTERIOR ELEVATIONS - VISITOR CENTER - 2nd FLOOR

A10 INTERIOR ELEVATIONS - MOGAN CULTURAL CENTER

A11 INTERIOR ELEVATIONS - BOOTT COUNTING HOUSE

A12 PARTITION TYPES

A13 DOOR TYPES, FRAME TYPES & DETAILS

A14 INTERIOR FINISHES, ACCESSORY, FIXTURE

A15 RESTROOM DETAILS

M1 MECHANICAL GENERAL NOTES AND LEGEND

M2 MECHANICAL DEMOLITION PLAN

M3 MECHANICAL MOGAN DEMOLITION PLAN

M4 MECHANICAL NEW PLAN

M5 MECHANICAL MOGAN NEW PLAN

P1 PLUMBING GENERAL NOTES AND LEGEND

P2 PLUMBING DEMOLITION PLAN

P3 PLUMBING MOGAN DEMOLITION PLAN

P4 PLUMBING NEW PLAN

P5 PLUMBING MOGAN NEW PLAN

F1 FIRE PROTECTION GENERAL NOTES AND LEGEND

F2 FIRE PROTECTION DEMOLITION PLAN

F3 FIRE PROTECTION MOGAN DEMOLITION PLAN

F4 FIRE PROTECTION NEW PLAN

F5 FIRE PROTECTION MOGAN NEW PLAN

E1 ELECTRICAL LEGEND AND ABBREVIATIONS

E2 DEMOLITION FLOOR PLANS

E3 DEMOLITION LIGHTING PLANS

E4 DEMOLITION MOGAN CULTURAL CENTER PLANS

E5 FLOOR PLANS

E6 LIGHTING PLANS

E7 MOGAN CULTURAL CENTER PLANS

E8 SCHEDULES & DIAGRAMS

E9 SCHEDULES & DIAGRAMS

David Lieb Rectangle

David Lieb Rectangle

David Lieb Rectangle

David Lieb Rectangle

David Lieb Rectangle

David Lieb Rectangle

David Lieb Rectangle

David Lieb Rectangle

David Lieb Rectangle

David Lieb Rectangle

ELEV

25'-0"

GENERAL LEGEND

SPOT ELEVATION KEY

ENLARGED PLAN KEY

ALIGN KEY

DETAIL NUMBER

DRAWING NUMBER

ROOM NAME

ROOM NUMBER

REVISION KEY

DIMENSION LINE

DETAIL KEY:

ROOM KEY:

NOT IN CONTRACT

(NIC) SHADING

COLUMN LINE INDICATORS

PARTITION TYPE

DOOR NUMBER

SEALANT & BACKER ROD

SEALANT

INTERIOR ELEVATION KEY -

MULTIPLE

1"

S

S

WALL SECTION KEY

AX

LOUVER TYPE?

LIMIT OF WORK

AX

AX

ROOM NAME

A

AX

1A

S - South

SAFB - Sound Attenuation

Fiber Batts

SC - Solid Core

SCHED - Schedule

SCR - Screw

SCRN - Screen

SECT - Section

SF - Square Foot or Feet

SHT - Sheet

SHTG - Sheathing

SHV - Shelving

SIM - Similar

SM - Sheet Metal

SOW - Scope of Work

SPEC - Specifications

SQ - Square

SS - Stainless Steel

SSF - Solid Surface

STAG - Stagger

STC - Sound Transmission

Class

STD - Standard

STG - Storage

STL - Steel

STN - Stone or Stantec

STR - Structural

SUSP - Suspended

SVF - Sheet Vinyl Flooring

SYM - Symbol

SYMM - Symmetrical

SYS - System

S4S - Surface Four Sides

T - Treads (Stairs)

T&B - Top and Bottom

T&G - Tongue and Groove

TBD - To Be Determinedr

TC - Top of Concrete

TEL - Telephone

TEMP - Temporary

TF - Top of Footing

TFF - Top of Finished

Floor

THK - Thickness

THRES - Threshold

THRU - Through

TMPD - Tempered

T.O. - Top Of

TOC - Top Of Concrete

TOL - Tolerance

TOM - Top Of Masonry

TOP - Top of Pavement

TOS - Top Of Steel

TOSL - Top of Slab

TOW - Top Of Wall

TRANS - Translucent

TYP - Typical

U/S - Underside

UL - Underwriters

Laboratory

UNEX - Unexcavated

UNFIN - Unfinished

UON - Unless Otherwise

Noted

UPS - Uninterruptible

Power Supply

UV - Ultraviolet

VAC - Vacuum

VAN - Vanity

VB - Vapor Barrier or Vinyl

Base

VCT - Vinyl Composition

Tile

VER - Verify

VERT - Vertical

VEST - Vestibule

VIF - Contractor to Verify

In Field

VNR - Veneer

VOC - Volatile Organic

Compound

VR - Vapor Retarder

VWC - Vinyl Wall Covering

W - West

W/ - With

W/O - Without

WD - Wood

WP - Working Point

WT - Weight

WTH - Width

ETR - Existing to Remain

EX / EXIST - Existing

EXH - Exhaust

EXP - Expansion

EXT - Exterior

F/F - Face to Face

FA - Fire Alarm

FACP - Fire Alarm Control

Panel

FE - Fire Extinguisher

FEC - Fire Extinguisher

Cabinet

FF&E/FFE - Furniture

Fittings &

Equipment

FFL - Finished Floor Level

FHP - Full Height Partition

FHY - Fire HydrantFIN -

Finish

FIXT - Fixture

FLG - Flange

FLR - Floor

FO - Face of

FOC - Face of Concrete

FOF - Face of Finish

FOM - Face of Masonry

FOS - Face of Stud

FPRF - Fireproofing

FR - Fire Resistant

FRT - Fire Retardant

Treated

FS - Full Size

FSH - Fire Sprinkler Head

FSTP - Firestopping

FT - Foot or Feet

FTR - Fin Tube Radiation

FURN - Furniture

FURR - Furring

FUT - Future

G - Gas

GA - Gauge

GALV - Galvanized

GC - General Contractor

GEN - Generator

GFI/GFCI - Ground Fault

(Circuit) Interrupter

GFRG - Glass Fiber

Reinforced Gypsum

GL - Glass

GND - Ground

GR - Grade

GRL - Grille

GRTG - Grating

GSKT - Gasket

GT - Grout

GWB - Gypsum Wall Board

HC - Hollow Core

HDBD - Hardboard

HDWD - Hardwood

HDW - Hardware

HGR - Hanger

HT - Height

HM - Hollow Metal

HMD - Hollow Metal Door

HNDRL - Handrail

HO - Hold Open

HORIZ - Horizontal

HP - High Point

HVAC - Heat, Ventilation &

Air Conditioning

ID - Inside Diameter

IF - Inside Face

IN - Inch or Inches

INSUL - Insulation

INT - Interior

JAN - Janitor

JT - Joint

KD - Knocked Down

KIT - Kitchen

KO - Knockout

KOP - Knockout Panel

KPL - Kickplate

L - Length or Left

LAD - Ladder

LAM - Laminate

LAV - Lavatory

LB - Pound

LBL - Label

LED - Light Emitting Diode

LF - Linear Foot or Feet

LH - Left Hand

LHR - Left Hand Reverse

LIN - Linear

LONG - Longitudinal

LP - Low Point

LT - Light

LTG - Lighting

LTWT - Lightweight

LVR - Louver

& - And

< - Angle

@ - At

C - Center Line

Ø - Diameter

# - Pound

± - Tolerance Dimension

A/E - Architect /

Engineer

AC - Air Conditioning

ACBL - Accessible (ADA

Compliant)

ACM - Asbestos Containing

Material

ACOUS - Acoustical

ACT - Acoustic Ceiling Tile

ADA - The Americans with

Disabilities Act

ADBL - Adaptable (ADA

Compliant)

ADDL - Additional

ADH - Adhesive

ADJ - Adjustable

ADJC - Adjacent

AFF - Above Finished

Floor

AH - Air Handler

ALUM - Aluminum

ALT - Alternate

ANOD - Anodized

AP - Access Panel

APPROX - Approximately

ARCH - Architect

ASC - Above Suspended

Ceiling

ASSY - Assembly

AVB - Air Vapor Barrier

BD - Board

BDY - Boundary

BETW - Between

BLDG - Building

BLKG - Blocking

BM - Beam

BO - By Others

BOD - Basis of Design

BOH - Back of House

BOT - Bottom

BYND - Beyond

C/C - Center to Center

CFCI - Contractor

Furnished/ Contractor

Installed

CG - Corner Guard

CHAN - Channel

CHFR - Chamfer

CIP - Cast in Place

CJ - Control Joint

CL - Center Line

CLG - Ceiling

CLO - Closet

CLR - Clear

CMPST - Composite

COL - Column

COMP - Compressible

CONC - Concrete

CONN - Connection

CONSTR - Construction

CONT - Continuous

CONTR - Contractor

COORD - Coordinate

CORR - Corridor

CPRS - Compressible or

Compression

CPT - Carpet

CSK - Countersunk

CSMT - Casement

CTR - Center

DBL - Double

DEMO - Demolition

DEPT - Department

DIA - Diameter

DIM - Dimension

DIV - Division

DN - Down

DO - Ditto

DOP - Door Opening

DR - Door

DST - Door Stop

DTL - Detail

DWG - Drawing

E - East

EA - Each

EL/ELEV - Elevation

ELEC - Electrical

EL/ELEV - Elevator

EMER - Emergency

ENGR - Engineer

ENTR - Entrance

EP - Electrical Panel

EQ - Equal

EQUIP - Equipment

MACH - Machine

MAINT - Maintenance

MAS - Masonry

MATL - Material

MAX - Maximum

MDF - Medium Density

Fiberboard

MDO - Medium Density

Overlay

MECH - Mechanical

MED - Medium

MEL - Melamine

MEMB - Membrane

MEZZ - Mezzanine

MFR - Manufacturer

MIN - Minimum

MISC - Miscellaneous

ML - Metal Lath

MLDG - Molding

MLWK - Millwork

MO - Masonry Opening

MTD - Mounted

MTL - Metal

MTR - Mortar

MULL - Mullion

MVBL - Movable

N - North

NA - Not Applicable

NAT - Natural

NIC - Not In Contract

NO - Number

NOM - Nominal

NTS - Not To Scale

OA - Overall

OC - On Center

OD - Outside Diameter

OF - Outside Face

OFCI - Owner

Furnished/Contractor

Installed

OFF - Office

OH - Overhead

OPNG - Opening

OPP - Opposite

P&S - Power & Signal

PAR - Parallel

PB - Particle Board

PC - Precast

PERF - Perforated

PERIM - Perimeter

PERP - Perpendicular

PL - Plate

PLAM - Plastic Laminate

PLAS - Plaster

PLBG - Plumbing

PLYWD - Plywood

PM - Pressed Metal

PNEU - Pneumatic

PNL - Panel

POL - Polished

POLY - Polyethelene

POP - Press-On Plate

PR - Pair

PRCST - Precast

PREFAB - Prefabricated

PREFIN - Prefinished

PT - Pressure Treated or

Post Tension

PTD - Painted

PTN - Partition

PV - Photovoltaic

PVG - Paving

QTY - Quantity

QUAL - Quality

R&R - Remove & Replace

R - Radius or (Stair) Risers

RAD - Radiator

RBR - Rubber

RCP - Reflected Ceiling Plan

RDG - Ridge

REC - Recessed

REF - Reference

REINF - Reinforced or

Reinforcing

REM - Removable

REQD - Required

REQMTS - Requirements

RESIL - Resilient

RF - Resilient Flooring

RFG - Roofing

RH - Right Hand

RHR - Right Hand Reverse

RLG - Railing

RM - Room

RO - Rough Opening

RSIC - Resilient Sound

Isolation Clip

RTN - Return

ABBREVIATIONS

1. MATERIALS AND PRODUCTS, CALLED OUT TO BE INSTALLED ON THE

DRAWINGS ARE TO BE NEW UON CONTRACTING OFFICER/DESIGNER WILL

PROVIDE SCHEDULE OF SALVAGED ITEMS, IF ANY, THAT ARE TO BE RE-

USED ON THIS PROJECT.

2. EXISTING GWB CEILINGS TO REMAIN TO BE PATCHED AND REPAIRED TO A

FINISH LEVEL CONSISTENT WITH NEW WORK.

3. DOWN LIGHTS, WALL WASHERS, SMOKE DETECTORS, EXIT SIGNS, AND

OTHER CEILING MOUNTED DEVICES TO BE CENTERED IN CEILING TILES AND

GWB SOFFITS, UON.

4. SPRINKLER HEADS TO BE CENTERED IN CEILING TILES AND GWB SOFFITS

IN BOTH DIRECTIONS UON.

5. DIMENSIONS OF FIXTURES, DEVICES, ETC. ARE TO CENTERLINE OF

FIXTURE, UON WHERE ITEMS ARE IN LINE, CENTERLINE OF ITEMS OR

GROUP OF ITEMS TO ALIGN, UON.

6. SPRINKLER HEADS SHOWN FOR ARCHITECTURAL DESIGN INTENT ONLY, NOT

FOR CODE DISTRIBUTION. SEE FIRE PROTECTION CONTRACT DRAWINGS

AND APPROVED SHOP DRAWINGS FOR DISTRIBUTION AND HYDRAULIC

CALCULATIONS.

RCP NOTES

DEMOLITION PLAN NOTES

1. THESE DEMOLITION DRAWINGS HAVE BEEN COMPILED FROM THE BEST

AVAILABLE INFORMATION AND ARE NOT INTENDED TO LIMIT THE SCOPE OF

THE WORK. CONTRACTOR TO INSPECT THE SITE AND SUBMIT ALL

DEMOLITION SCOPE QUESTIONS PRIOR TO BIDDING AND VERIFY THE

INFORMATION HEREIN SUPPLIED.

2. INTENT IS TO REMOVE EVERYTHING NECESSARY TO ALLOW NEW

CONSTRUCTION TO BE ACCOMPLISHED. SEE DRAWINGS SHOWING NEW

CONSTRUCTION.

3. PRIOR TO CARRYING OUT DEMOLITION WORK ON PARTITIONS INDICATED TO

BE REMOVED, EXISTING FRAMING TO BE EXPOSED FOR CONTRACTING

OFFICER/ENGINEER’S REVIEW.

4. REFER TO STRUCTURAL DOCUMENTS FOR REMOVAL OF ANY BUILDING

ELEMENTS AND REVIEW WITH CONTRACTING OFFICER/STRUCTURAL ENGINEER

PRIOR TO DEMOLITION.

5. DO NOT REMOVE ANY STRUCTURAL ELEMENTS (FLOORS, COLUMNS, BEAMS,

LOAD BEARING WALLS, ETC.) WITHOUT THE REVIEW AND APPROVAL OF THE

CONTRACTING OFFICER AND STRUCTURAL ENGINEER.

6. LOCATIONS OF NEW OPENINGS ARE SHOWN ON DRAWINGS. REVIEW FOR

COORDINATION WITH NEW CONSTRUCTION AND NOTIFY ARCHITECT OF ANY

DISCREPANCIES PRIOR TO DEMOLITION.

7. PROTECT EXISTING FINISHES, TRIM, FIXTURES, AND EQUIPMENT TO REMAIN.

8. SEE PLAN AND PLAN NOTES FOR ITEMS TO BE SALVAGED. CONFIRM WITH

OWNER ALL ITEMS TO BE SALVAGED AND RETAINED. DO NOT DAMAGE.

9. PROTECT OR REMOVE AND STORE EXISTING PERIMETER WINDOW

TREATMENTS. NOTIFY LANDLORD OF ANY DAMAGED OR NON-FUNCTIONING

BLINDS IN WRITING PRIOR TO COMMENCING WORK.

10. REMOVE FINISH FLOORING MATERIAL AND BACKERS, UON REMOVE

EXISTING ADHESIVES AS REQUIRED TO ALLOW PROPER INSTALLATION OF

NEW FLOORING, PER MANUFACTURER’S REQUIREMENTS.

11. REMOVE EXISTING WALL BASE, UON.

12. REMOVE EXISTING APPLIED WALL FINISHES, UON.

13. REMOVE EXISTING LIGHT FIXTURES, UON.

14. REMOVE ELECTRICAL AND SIGNAL DEVICES AND BOXES AT FLOORS AND

EXISTING WALLS TO REMAIN, UON.

15. MAINTAIN EXISTING PERIMETER SOFFIT/WINDOW TREATMENT DETAIL, UON.

16. EXISTING COLUMN ENCLOSURES TO REMAIN, UON.

TYPICAL MOUNTING LOCATIONS

1'-6"

4'-0"

6'-8"

FIRE ALARM

ANNUNCIATION

DEVICE

THERMOSTATS AND

WALL PHONES

LIGHTING SWITCHES

FIRE ALARM

PULL STATION

RECEPTACLES

TELE-DATA OUTLET

/ COMPUTER

INTERFACE

FINISH FLOOR

NOT TO SCALE

3'-0"

FIRE EXTINGUISHER

CABINET

CARD READER

MIN

6" DOOR & FRAME

MIN. @ ALL DEVICES FROM CORNER

1'-6"

1. INSTALL DEVICES AS INDICATED ABOVE UON.

2. MEASURE MOUNTING HEIGHTS FROM CENTERLINE OF DEVICE TO FINISH

FLOOR UON.

3. INSTALL DEVICES ON A COMMON VERTICAL CENTERLINE WHEREVER

POSSIBLE.

4. DIMENSIONS AT LOAD CENTER ARE TO EDGE OF DOOR.

1. EACH BIDDER SHALL VISIT THE SITE AND EXAMINE THE SITE TO ENSURE THEIR KNOWLEDGE OF THE

CONDITIONS AFFECTING THE WORK.

2. DETAILS AND SECTIONS ON THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS. DETAILS NOTED "TYPICAL"

OR "TYP" IMPLY THE SAME CONDITION IS REPEATED AT OTHER LOCATIONS. DETAILS NOTED “SIMILAR” OR

“SIM” IMPLY THE CONDITION IS TREATED SIMILARLY IN OTHER LOCATIONS BUT WITH SLIGHT MODIFICATIONS

TO BE MADE BY CONTRACTOR TO ACCOMMODATE MINOR VARIATIONS.

3. MATERIALS AND PRODUCTS CALLED OUT TO BE INSTALLED ON THE DRAWINGS ARE TO BE NEW UON

CONTRACTING OFFICER WILL PROVIDE SCHEDULE OF SALVAGED ITEMS, IF ANY, THAT ARE TO BE RE-USED ON

THIS PROJECT.

4. SIDES OF DOOR OPENINGS TO BE A MINIMUM OF 6" FROM NEAREST PERPENDICULAR PARTITION, UON.

5. REVIEW LAYOUTS FOR PARTITIONS IN FIELD WITH THE ARCHITECT/DESIGNER PRIOR TO START OF

CONSTRUCTION.

6. ALIGN CENTERLINES OF FIRE EXTINGUISHER CABINETS AND MEP/FP DEVICES ON WALLS IN THE SAME

LOCATION.

7. WHERE NEW PARTITIONS ABUT EXISTING SURFACES, REMOVE EXISTING CORNER BEAD AND PROVIDE SMOOTH

FINISH AT INTERSECTION.

8. PATCH PARTITIONS TO REMAIN WHERE WALL RECEPTACLES, FACE PLATES, WALL BASE, ETC. ARE REMOVED.

9. EXISTING FLOORS, PARTITIONS, CEILINGS, INTERIOR COLUMNS, AND CORRIDOR WALLS TO BE PATCHED AND

REPAIRED AS NEEDED TO MAINTAIN ORIGINAL ACOUSTICAL AND RATED FIRE/SMOKE DESIGN INTENT.

PENETRATIONS AND JOINTS ARE TO BE SEALED TO MAINTAIN FIRE/SMOKE RATING AND ACOUSTICAL RATING.

10. EXISTING WALLS, COLUMN ENCLOSURES, SOFFITS ETC. TO REMAIN ARE TO BE PATCHED AND REPAIRED TO

MEET REQUIREMENTS OF NEW SURFACES UON.

11. DOOR NUMBERS TO CORRESPOND TO ROOM NUMBERS, UON.

12. REINSTALL REMOVED PERIMETER WINDOW TREATMENT. ADJUST/MODIFY/REPLACE WINDOW TREATMENTS AS

REQUIRED TO ACCOMMODATE NEW CONSTRUCTION.

13. DIMENSIONS:

A. DIMENSIONS ARE TO FINISHED FACE OF PARTITION UON

B. DRAWINGS ARE NOT TO BE SCALED; VERIFY ANY MISSING OR CONFLICTING WRITTEN DIMENSIONS WITH THE

CONTRACTING OFFICER/DESIGNER PRIOR TO CONSTRUCTION.

C. NOTIFY ARCHITECT/DESIGNER OF CONDITIONS WHERE CLEAR OR CRITICAL DIMENSIONS ARE DESIGNATED

BUT CANNOT BE MET OR WHERE CORRIDOR/AISLE WIDTH CANNOT MEET THE MINIMUM REQUIREMENTS

(3'-8" UON).

D. MAINTAIN FINISH FLOOR BASE ELEVATION THROUGHOUT THE CONTRACT AREA SUCH THAT DIMENSIONS

INDICATED AS ABOVE FINISH FLOOR ARE AT THE SAME ELEVATION.

14. PROVIDE FIRE EXTINGUISHERS (WITH CABINETS) IN QUANTITIES AND LOCATIONS ON DWGS, BUT IN NO CASE

LESS THAN AMOUNT REQUIRED BY CODE. REVIEW FINAL LOCATIONS WITH THE ARCHITECT/DESIGNER PRIOR

TO START OF CONSTRUCTION. PARTITION DEPTH AT FIRE EXTINGUISHER CABINET LOCATIONS TO ACCOMMODATE

FULL CONCEALMENT OF RECESSED CABINETS, UON.

PARTITION PLAN NOTES

1. REFER TO ELEVATIONS, ENLARGED PLANS, DETAILS, SCHEDULES AND

SPECIFICATIONS FOR ADDITIONAL FINISH INFORMATION.

2. FLOORING TRANSITIONS AT DOOR OPENING TO OCCUR UNDERNEATH

DOOR, UON.

3. INCLUDE FLOORING TRANSITION STRIP AT ALL EXISTING DOOR OPENINGS

TO NIC SPACES. CONFIRM MATERIAL, PROFILE, AND FINISH WITH

CONTRACTING OFFICER.

4. DO NOT PAINT OVER FIRE RATING TAGS ON RATED DOORS AND FRAMES.

5. WALLS TO BE PAINTED EGGSHELL FINISH, UON

DOORS TO BE PAINTED SEMI-GLOSS, UON

FRAMES TO BE PAINTED SEMI-GLOSS, UON

CEILINGS TO BE PAINTED EGGSHELL FINISH, UON

6. AT PARTITIONS AND GWB SOFFITS/CEILINGS THAT HAVE BEEN PATCHED,

PRIME AND PAINT ENTIRE SURFACE.

7. ALL PAINTED WALL FINISHES GWB TO RECEIVE LEVEL 5 FINISH PRIOR

TO INSTALLATION OF FINISH.

FINISH PLAN NOTES

SUB SHEET NO.DESIGNED:

CADD:

TECH REVIEW:

DATE:

TITLE OF SHEET DRAWING NO.

PMIS SHEET

OF

NO.

99B

LOWE 475

187375

A0

GENERAL NOTES &

LEGENDS

NPS LOWE TOILETS

PITRE

PITRE

HICKS

05/18/2023

MEN'S TOILET WOMEN'S TOILET

SERVICE

AREA

CORRIDOR

JANITOR

EXITWAY

F.D.

F.D.

JANITOR

MEN'S TOILET

WOMEN'S TOILET

'-2

F.D.

F.D.

SERVICE

AREA

CORRIDOR

JANITOR

EXITWAY

WOMEN'S TOILETMEN'S TOILET

MEN'S TOILET WOMEN'S TOILET

DEMOLITION RCP LEGEND

EXISTING CEILING TO BE REMOVED

EXISTING PARTITION TO REMAIN

EXISTING ELEMENT TO BE REMOVED

DEMOLITION PLAN LEGEND

EXISTING DOOR TO REMAIN

EXISTING DOOR TO BE REMOVED

EXISTING FLOOR FINISH TO BE REMOVED

SUB SHEET NO.DESIGNED:

CADD:

TECH REVIEW:

DATE:

TITLE OF SHEET DRAWING NO.

PMIS SHEET

OF

NO.

99B

LOWE 475

187375

A3

MOGAN CULTURAL

CENTER DEMO PLANS

AND RCP

NPS LOWE TOILETS

Designer

Author

Checker

05/18/2023

1/4" = 1'-0"A3

1 MOGAN CULTURAL CENTER - 1ST FLOOR DEMO

1/4" = 1'-0"A3

2 MOGAN CULTURAL CENTER - 3RD FLOOR DEMO

1/4" = 1'-0"A3

3 MOGAN CULTURAL CENTER 1ST FLOOR DEMO RCP

1/4" = 1'-0"A3

4 MOGAN CULTURAL CENTER 2ND FLOOR DEMO RCP

GENERAL DEMOLITION NOTES:

1. REMOVE ALL FINISHES, FIXTURES AND ACCESSORIES.

REFERENCE MEP DRAWINGS FOR ADDITIONAL INFORMATION.

0' 2' 4' 8'

George Little Callout Sawcut and carefully remove portions of CMU chase wall (approx. 50 sf each room) to gain plumbing access. Cut/cap existing supply and waste piping behind wall. Install new fixture carriages, at new locations. Extend existing piping to new fixture location. Refer to A7, A10, and A14 for additional notes and locations (both rooms). Infill walls with matching size CMU/mortar, coursing to match existing. Provide access panels for supply line maintenance at fixtures.

George Little Callout Cap existing piping at demolished second sink behind wall. Infill walls with matching size CMU/mortar, coursing to match existing (both rooms).

F

OS

OS

OS OS

A108 A10 2

MCC 113

MEN'S TOILET

MCC 114

WOMEN'S TOILET

SERVICE

AREA

CORRIDOR

JANITOR

EXITWAY

ACCUATED DOOR

OPENER

MCC 114MCC 113

M

IN

C L R

'-0

/8

'-6

M

IN

C L R

'-0

/8

'-0

F.D.

F.D.

A10 10

A1016

JANITOR

MCC 218

MEN'S TOILET MCC 219

WOMEN'S TOILET

ACUATED DOOR

OPENER.

'-0

MCC 219MCC 218

M

IN

C L R

'-0

M

IN

C L R

'-0

F.D.

F.D.

'-6

ACT-1 8' - 3" ACT-1 8' - 3"

LIGHTING, SEE ELEC

L2L2

CORRIDOR

JANITOR

EXITWAY

SERVICE

AREA

L1L1

L6

L6

L6 L6

L6

L6

ACT-1 8' - 0" ACT-1 8' - 0"

L2 L2

L1 L1

L6

L6

L6L6

L6

L6

RSF

RSF

MCC 218

MEN'S TOILET MCC 219

WOMEN'S TOILET

JANITOR

RSF

RSF

LIGHTING LEGEND

L1

L2

L5, L7

L4

RECESSED LINEAR LED SLOT

RECESSED LED

2'x2' LED TROFFER

LED LINEAR PENDANT - (4', 6')

2' x 6" WALL MOUNTED FIXTURE

L6 2' x 6" LAY-IN FIXTURE

SUB SHEET NO.DESIGNED:

CADD:

TECH REVIEW:

DATE:

TITLE OF SHEET DRAWING NO.

PMIS SHEET

OF

NO.

99B

LOWE 475

187375

A7

MOGAN CULTURAL

CENTER PLANS AND RCP

NPS LOWE TOILETS

Designer

Author

Checker

05/18/2023

A7

MOGAN CULTURAL CENTER -

1ST FLOOR

A7

MOGAN CULTURAL CENTER -

3RD FLOOR

A7

MOGAN CULTURAL CENTER

1ST FLOOR RCP

A7

MOGAN CULTURAL CENTER

2ND FLOOR RCP

A7

FINISH PLAN-MOGAN

CULTURAL CENTER-1ST FLR

FINISH PLAN

A7

FINISH PLAN-MOGAN

CULTURAL CENTER-2ND FLR

0' 2' 4' 8'

David Lieb Rectangle

David Lieb Rectangle

David Lieb Rectangle

David Lieb Rectangle

David Lieb Callout

REF DETAIL A-15 - ACT TO EXTEND FULL ROOM, RECESSED LIGHTING (BOTH ROOMS)

David Lieb Callout

REF DETAIL A-15 - ACT TO EXTEND FULL ROOM, RECESSED LIGHTING (BOTH ROOMS)

George Little Line

George Little Line

George Little Line

George Little Line

George Little Line

George Little Line

George Little Line

George Little Line

George Little Callout Note new location for toilets.

George Little Line

George Little Line

George Little Line

George Little Line

George Little Callout Utilize plumbing from this demolished sink

George Little Line

George Little Line

George Little Line

George Little Line

George Little Line

George Little Line

George Little Line

George Little Line

George Little Line

George Little Line

George Little Line

George Little Line

George Little Callout Utilize plumbing from this demolished sink

George Little Callout Note new location for toilet and urinal.

George Little Callout Utilize plumbing from this demolished sink

George Little Line

George Little Line

George Little Callout Utilize plumbing from this demolished sink

George Little Line

George Little Line

4" INTEGRAL BASE, TYP

'-9

TL

LIGHT COVE, TYP

AC-7

2'-11 3/4"

PT

4'-0"

SURFACE MOUNTED

DOOR ACCUATOR

M A

X

'-0

AC-16

PATCH IN-FILL CMU

'-9

TL

PT

AC-11

AC-2

'-9

TL

AC-9

2'-0" 2'-2"

MCC 114

AC-2

AC-11

AC-12

TL

PT

'-9

AC-16

1'-6" 2'-5 3/8"P-1

4'-9"

'-0

EQ EQ

4" INTEGRAL BASE, TYP

'-9

TL

PT

AC-7

3'-0"

AC-12

AC-2

AC-11

MCC 113

'-9

TL

PT

P-1

4'-10"

'-0

2'-7 3/4" 3'-11 3/4" 1'-6"

EQ EQEQ EQ

AC-2

AC-5

'-9

TL

PT

AC-9

1'-11 1/2"

AC-11

2'-2"

PT

1 AC-16

4'-0"

SURFACE MOUNTED

DOOR ACCUATOR

M A

X

'-0

PATCH IN-FILL CMU

'-9

TL

'-9

TL

PT

AC-7

10 5/8"

EQ EQ

PT

SURFACE MOUNT

DOOR ACCUATOR

M A

X

'-0

1'-8 3/4"2'-0"

EXISTING METAL ACCESS PANEL

PATCH IN-FILL CMU

'-9

TL

PT

4" INTEGRAL BASE, TYP

PROVIDE PRIVACY FILM AT

WINDOWS, TYP

AC-9

EQEQ

'-9

TL

1'-9 1/2"

'-9

AC-11 AC-12

TL

PT

1 AC-2

P-1

'-0

3'-11 7/8"

3'-5 1/2" 1'-6"

'-9

TL

PT

AC-12

AC-11

'-9

TL

PT

P-1

AC-16

AC-2

4'-0"

2'-10 1/4" 3'-5 1/2"

'-0

EQ EQEQ EQ

2'-3 1/8"

PT

1EXISTING WINDOW

4" INTEGRAL BASE, TYP

LIGHT COVE, TYP

EQ EQ

'-9

TL

AC-16 AC-7

PT

5'-11 1/2"

3'-10 1/2"

SURFACE MOUNTED

DOOR ACCUATOR

M A

X

'-0

PATCH IN-FILL

CMU

'-9

AC-9

TL

EQ EQ

2'-5 3/4"

SUB SHEET NO.DESIGNED:

CADD:

TECH REVIEW:

DATE:

TITLE OF SHEET DRAWING NO.

PMIS SHEET

OF

NO.

99B

LOWE 475

187375

A10

INTERIOR ELEVATIONS -

MOGAN CULTURAL

CENTER

NPS LOWE TOILETS

PITRE

PITRE

HICKS

05/18/2023

A10

MOGAN 1ST FLOOR WOMEN'S

NORTH

A10

MOGAN 1ST FLOOR WOMEN'S

EAST

A10

MOGAN 1ST FLOOR WOMEN'S

SOUTH

A10

MOGAN 1ST FLOOR WOMEN'S

WEST

A10

MOGAN 1ST FLOOR MEN'S

NORTH

A10

MOGAN 1ST FLOOR MEN'S

EAST

A10

MOGAN 1ST FLOOR MEN'S

SOUTH

A10

MOGAN 1ST FLOOR MEN'S

WEST

A10

MOGAN 2ND FLOOR WOMEN'S

NORTH

A10

MOGAN 2ND FLOOR WOMEN'S

EAST

A10

MOGAN 2ND FLOOR WOMEN'S

SOUTH

A10

MOGAN 2ND FLOOR WOMEN'S

WEST

A10

13 MOGAN 2ND FLOOR MEN'S

A10

MOGAN 2ND FLOOR MEN'S

EAST

A10

MOGAN 2ND FLOOR MEN'S

SOUTH

A10

MOGAN 2ND FLOOR MEN'S

WEST

GENERAL NOTES:

1. REFER TO A14 FOR ACCESSORY SCHEDULE AND

MOUNTING DETAILS.0' 2' 4' 8'

George Little Rectangle

George Little Rectangle

George Little Rectangle

George Little Rectangle

George Little Rectangle

George Little Rectangle

George Little Callout Infill wall w/CMU behind new ceramic tile.

George Little Callout Infill wall w/CMU behind new ceramic tile.

George Little Callout Cap plumbing, patch wall w/CMU

George Little Callout Move plumbing for toilets over, patch wall w CMU behind new ceramic tile.

George Little Rectangle

George Little Rectangle

George Little Callout Infill wall w/CMU behind new ceramic tile.

George Little

Infill wall w/CMU behind new ceramic tile.

SEE PLAN FOR

PARTITION TYPE

KERF BLOCKING TO

ALLOW FOR

INSTALLATION TIGHT

TO GWB

PROVIDE 3/4" FRT

PLYWOOD BLOCKING

MAINTAIN CONTINUITY

OF PARTITION WITH

HIGHEST PRIORITY

LOWEST PRIORITY. SEE

PARTITION PLAN FOR TYPE.

HIGHEST PRIORITY. SEE

PARTITION PLAN FOR TYPE.TWO HOUR FIRE & SMOKE PARTITION PRIORITY 1 - HIGHEST

WALL PRIORITY LEGEND

TWO HOUR FIRE PARTITION

TWO HOUR SHAFT WALL

ONE HOUR FIRE & SMOKE PARTITION

ONE HOUR FIRE PARTITION

PRIORITY 2

PRIORITY 3

PRIORITY 4

NON-RATED PARTITION PRIORITY 5 - LOWEST

BRACING AT EACH SET OF STUDS

(48"OC MAX. VERT SPACING)

41 DOUBLE STUD PARTITION

S

1-5/8" NON-LOAD BEARING MTL

FRAMING @ 16" OC MAX, L/240

MAX, SEE SPEC

FINISH FLOORING. (SEE FINISH SCHEDULE)

1 LAYER OF 5/8" GWB, EACH SIDE

S

SS

EXISTING DECK

SLIP-JOINT FOR DEFLECTION. TYPICAL.

S STD SEALANT AT PARTITIONS

PENETRATIONS ABOVE CEILING:

TYPE 'A', UNLESS RATED

TYPE 'A' SAFB (3 1/2" BATT EACH SIDE)

CERAMIC TILE ON THISET, 1/2" CEMENT BACKER BOARD

BULLNOSE EDGE TILE, TYP

EXISTING DECK

3-5/8" NON-LOAD BEARING MTL FRAMING @

16" OC MAX, L/240 MAX, SEE SPEC

PROJECTION OF CEILING.

(REFER TO FINISH SCHEDULE FOR TYPE)

TYPE 'A' SAFB (FULL STUD DEPTH)

STD SEALANT AT PARTITIONS THAT ARE NEITHER

TYPE 'A' NOR RATED AND ACOUSTIC SEALANT AT

TYPE 'A', UNLESS RATED

FINISH FLOORING. (SEE FINISH SCHEDULE)

1 LAYER, 5/8" TYPE X GWB, EACH SIDE

S

SLIP-JOINT FOR

DEFLECTION.

2A

2 38-42 STC1HR RATED (UL DESIGN #U465)

W/ ACOUSTICAL INSUL. & 1HR RATED (UL DESIGN #U465) 43-48 STC

1A

1 38-42 STCSINGLE STUD PARTITION

W/ ACOUSTICAL INSULATION 43-48 STC

SS

SS

PENETRATIONS ABOVE CEILING:

1. TYPE 'A', UNLESS RATED: CONT. FILL ANNULAR

OPENING W/SAFB & ACOUSTIC SEALANT

2. RATED PARTITION: LISTED THRU-PENETRATION

FIRESTOP SYSTEM TO MAINTAIN REQUIRED RATING

FLOOR TO PARTITION:

RATED PARTITION: CONT. LISTED FIRE-RESISTIVE

JOINT SYSTEM TO MAINTAIN REQUIRED RATING

1B 6" STUD W/ ACOUSTICAL INSULATION 43-48 STC

CERAMIC TILE ON THISET, 1/2" CEMENT BACKER BOARD

23A

23 SING. STUD FURRING PARTITION

WITH ACOUSTICAL INSULATION

EXISTING DECK

2-1/2" NON-LOAD BEARING MTL FRAMING,

16" OC MAX, L/240 MAX, SEE SPEC

PROJECTION OF CEILING.

(SEE FINISH SCHEDULE FOR TYPE)

FINISH FLOORING. (SEE FINISH SCHEDULE)

1 LAYER OF 5/8" GWB. ONE SIDE ONLY

S

SLIP-JOINT FOR DEFLECTION

EXISTING PERIMETER EXTERIOR WALL OR INTERIOR BARRIER WALL

(SEE PLANS FOR LOCATIONS)

S

INTERIOR SIDE

S

STD SEALANT AT PARTITIONS THAT ARE NEITHER

TYPE 'A' NOR RATED AND ACOUSTIC SEALANT AT

TYPE 'A', UNLESS RATED

TYPE 'A' SAFB (FULL STUD DEPTH)

BOOTT COUNTING, ONE LAYER OF 5/8" ON

BACK SIDE, PTD WHITE. SEE PLANS

CERAMIC TILE ON THISET, 1/2" CEMENT BACKER

BOARD

Level 1

0"

Level 1

0' - 0"

'-1

/4

NEW SANITARY LINE. REF

PLUMBING DRAWINGS

TYPE 1A PARTITION

THINSET CERAMIC TILE

INTEGRAL COVE BASE (1" RADIUS)

LGMF INSTALLED ON FLAT TO

CREATE CHASE FOR SANITARY LINE

CONT EPOXY FLOORING UP

AND ONTO LEDGE

EXISTING DECK

74 EXISTING CMU WALL

RESINOUS FLOORING AND 4"

INTEGRATED BASE

PROJECTION OF CEILING.

(SEE FINISH SCHEDULE FOR TYPE)

CERAMIC TILE ON THINSET; SEE ELEVATIONS

FOR HEIGHT:

1/2" CEMENT BACKER BOARD ADHERED AND

MECHANICALLY ATTACHED TO EXISTING CMU

1/2" GWB ADHERED AND MECHANICALLY ATTACHED

TO EXISTING CMU

EXISTING CMU WALL

S

EXISTING DECK

75 EXISTING EXTERIOR MASONRY

RESINOUS FLOORING AND 4"

INTEGRATED BASE

CERAMIC TILE ON THINSET; SEE ELEVATIONS

FOR HEIGHT:

1/2" CEMENT BACKER BOARD ON 1/2"

FURRING STRIPS

1/2" GWB ON 1/2" FURRING STRIPS

EXISTING EXTERIOR MASONRY WALL

S

SUB SHEET NO.DESIGNED:

CADD:

TECH REVIEW:

DATE:

TITLE OF SHEET DRAWING NO.

PMIS SHEET

OF

NO.

99B

LOWE 475

187375

A12

PARTITION TYPES

NPS LOWE TOILETS

PITRE

PITRE

HICKS

05/18/2023

A12

1 PTN - CONCEALED BLOCKING

A12

2 PTN - PRIORITY KEY

1 1/2" = 1'-0"A12

5 BOOTT COUNTING - WALL BASE AT PLUMBING DRAIN

2" 2"

HM1

FRAME TYPESDOOR TYPES

F

FLUSH

NOTES:

-REFER TO DOOR SCHEDULE FOR DOOR HEIGHTS AND WIDTHS.

-EXISTING DOORS TO REMAIN TO BE CLEANED AND REFINISHED AS NECESSARY.

-EXISTING DOOR FRAMES TO REMAIN TO BE CLEANED, PREPPED AND REPAINTED.

-REFER TO SPECIFICATION SECTION 101423 FOR SIGNAGE TYPES

AL1SP

SLIDING POCKET

DOOR

LV

SINGLE

LOUVER

6" 6"

UNDERCUT

2"2"

4"

'-8

4"

'-8

SIGN SIGN

1. NEW HARDWARE TO MATCH EXISTING TO REMAIN, UON

2. DOOR LEVERS TO BE MOUNTED AT THE SAME HEIGHT AS EXISTING.

3. COORDINATE ACCUATORS AT EXISTING DOORS. SEE PLANS AND ELEVATIONS.

4. GC TO VERIFY EXISTING DOOR DIMENSIONS. NEW DOORS TO MATCH EXISTING SIZES.

DOOR HARDWARE NOTES

SEE PARTITION PLAN FOR WALL

TYPES

SCHEDULED DOOR

S

S

HOLLOW METAL FRAME - JAMB

PROVIDE DOUBLE

STUDS AT JAMBS TYP.

ROOM SIDE

PUBLIC SIDE

SEE PARTITION PLAN FOR WALL

TYPES

HOLLOW METAL FRAME - HEAD

SCHEDULED DOOR

JAMB BEYOND

SS

PUBLIC SIDE ROOM SIDE

REFER TO RCP FOR CEILING

TYPE

ANGLE BRACING ABOVE JAMB

SIDE

DOOR - REFER TO DOOR

SCHEDULE

GUIDES BEYOND

SEE PARTITION PLAN

ALUMINUM PKT. DR. FRAME -

HEAD. POCKET DOOR HEAD

ASSEMBLY

TYP.

METAL FRAMING

BRACED TO STRUCTURE

ABOVE

POCKET DOOR TRACK

SEE DOOR HARDWARE

SCHEDULE

FINISHED FLOOR

/2

BUILT UP HEADER

/4

M

A X

ANGLE SUPPORTS ABOVE

LATCH SIDE; ABOVE CEILING

SEE PARTITION PLAN

DOOR - REFER TO DOOR

SCHEDULE

PROVIDE DOUBLE STUDS

ALUMINUM POCKET DOOR

FRAME - JAMB

1 1/2"

CONTINUOUS BLOCKING

SCHEDULED SHAFT WALL

ASSEMBLY

/2

HOISTWAY ENTRY SILL

BY ELEVATOR MFR.

HOISTWAY ENTRY DOOR

BY ELEVATOR MFR.

HOISTWAY ENTRY FRAME JAMB

BY ELEVATOR MFR.

HOISTWAY

SUB SHEET NO.DESIGNED:

CADD:

TECH REVIEW:

DATE:

TITLE OF SHEET DRAWING NO.

PMIS SHEET

OF

NO.

99B

LOWE 475

187375

A13

DOOR TYPES, FRAME

TYPES & DETAILS

NPS LOWE TOILETS

PITRE

PITRE

HICKS

05/18/2023

DOOR SCHEDULE

DOOR

NO. From Room: Name

DOOR FRAME DETAIL

HDW

SET

FIRE

RTG

SECURITY

NOTES COMMENTSWTH HT THK TYPE MATL FIN TYPE MATL FIN

Head

Detail Jamb Detail

BCH 100 FAMILY RESTROOM 3'-0" 6'-8" 1 3/4" LV WD CLR HM1 HM PTD 2/A-13 1/A-13 -

BCH 101 UNISEX TOILET 3'-0" 6'-8" 1 3/4" LV WD CLR HM1 HM PTD 2/A-13 1/A-13 -

BCH 102 UNISEX TOILET 3'-0" 6'-8" 1 3/4" LV WD CLR HM1 HM PTD 2/A-13 1/A-13 -

BCH 103 UNISEX TOILET 3'-0" 6'-8" 1 3/4" LV WD CLR HM1 HM PTD 2/A-13 1/A-13 -

BCH 104 UNISEX TOILET 3'-0" 6'-8" 1 3/4" LV WD CLR HM1 HM PTD 2/A-13 1/A-13 -

BCH 105 UNISEX TOILET 3'-0" 6'-8" 1 3/4" LV WD CLR HM1 HM PTD 2/A-13 1/A-13 -

BCH 106 STORAGE CLOSET 2'-6" 6'-8" 1 3/4" F WD CLR HM1 HM PTD 2/A-13 1/A-13 -

BCH 107 MECHANICAL 3'-0" 7'-0" 1 3/4" F WD CLR HM1 HM PTD 2/A-13 1/A-13 45MIN

MCC 113 MEN'S TOILET 3'-0" 7'-0" 1 3/4" LV WD PTD ETR FRAME - PTD - - - ACUATED DOOR OPENER

MCC 114 WOMEN'S TOILET 3'-0" 7'-0" 1 3/4" LV WD PTD ETR FRAME - PTD - - - ACUATED DOOR OPENER

MCC 218 MEN'S TOILET 3'-0" 7'-0" 1 3/4" LV WD PTD ETR FRAME - PTD - - - ACUATED DOOR OPENER

MCC 219 WOMEN'S TOILET 3'-0" 7'-0" 1 3/4" LV WD PTD ETR FRAME - PTD - - - ACUATED DOOR OPENER

VC 005 UNISEX TOILET 3'-0" 7'-0" 1 3/4" SP WD PTD AL1 AL 4/A-13 3/A-13 - SLIDING POCKET DOOR w/ ALUM FRAME

VC 007 MEN'S TOILET ROOM 3'-0" 7'-0" 1 3/4" LV WD PTD HM1 HM 2/A-13 1/A-13 -

VC 008 WOMEN'S TOILET ROOM 3'-0" 7'-0" 1 3/4" LV WD PTD HM1 HM 2/A-13 1/A-13 -

VC 008B WOMEN'S TOILET ROOM 3'-0" 7'-0" 1 3/4" SP WD PTD AL1 AL 4/A-13 3/A-13 - SLIDING POCKET DOOR w/ ALUM FRAME

VC 108 UTILITY CLOSET 3'-0" 7'-0" 1 3/4" LV WD PTD ETR FRAME - PTD - - -

VC 109 TOILET 3'-0" 7'-0" 1 3/4" LV WD PTD ETR FRAME - PTD - - -

VC 111 TOILET 3'-0" 7'-0" 1 3/4" SP WD PTD AL1 AL 4/A-13 3/A-13 - SLIDING POCKET DOOR w/ ALUM FRAME

A13

1 HM FRAME - DR JAMB @ GWB1

A13

2 HM FRAME - DR HEAD @ GWB1

A13

4 AL FRAME - DR HEAD @ POCKET

A13

3 AL FRAME - DR JAMB @ POCKET STRIKE

A13

5 HOISTWAY ENTRY JAMB @ SHAFT WALL

dlieb Rectangle

David Lieb Rectangle

David Lieb Rectangle

David Lieb Rectangle

David Lieb Callout

HM1

David Lieb Line

David Lieb Line

LOCK

ACCESSIBLE URINAL STD URINALACCESSIBLE WC

LAVATORY

T O

P O

F S

E A

T

M A

X

3'-6" 1'-6"

" MAX

1'-0"

3'-6"

3'-6"

MAX

6"

'-0

'-5

M

A X

'-8

M

A X

T O

R

IM

O F

S

IN

K

'-1

M A

X

M

IN

8" MIN

M A

X A

L L S

T A

L L S

C O

A T

H O

O K

'-1

B O

T O

F R

E F

L E

C T

IV

E

S U

R F

A C

E

'-4

M

A X

RIM EXTENDS 14" MIN

FROM WALL

WALL MOUNTED ACCESSORIES

M A

X A

T C

O U

N T

E R

M A

X T

O B

O T

T O

M O

F

R E

F L E

C T

IV

E

S U

R F

A C

E

T O

O P

E R

A B

L E

P A

R T

30" MIN

17" MIN

MAX

6"

M

IN

AC-2

AC-4

AC-11

AC-13

AC-16

AC-11

AC-6

AC-17

AC-9

AC-10 AC-12

AC-16

TOILET ROOM FIXTURE & ACCESSORY MOUNTING LOCATIONS

AC-12

ACCESSIBLE WC

EQ A EQ A EQ B EQ B

AC-12

'-0

LOCK

STANDARD WC

T O

P O

F S

E A

T

" 4

M A

X A

L L S

T A

L L S

C O

A T

H O

O K

'-0

AC-2

AC-4

AC-13

AC-16

EQ EQ

STANDARD WC

T O

S P

O U

T

'-0

M

A X

'-6

DRINKING FOUNTAINS

M

IN

AC-1

'-6

3'-5"

'-0

2'-2"

M A

X

3'-6" MIN.

A D

JU

S

T A

B L E

H E

IG

H

T

AC-18

M A

X

2'-2"

AC-2

W H

E N

O P

E N

'-1

A F

F

SUB SHEET NO.DESIGNED:

CADD:

TECH REVIEW:

DATE:

TITLE OF SHEET DRAWING NO.

PMIS SHEET

OF

NO.

99B

LOWE 475

187375

A14

INTERIOR FINISHES,

ACCESSORY, FIXTURE

NPS LOWE TOILETS

PITRE

PITRE

HICKS

05/18/2023

ACCESSORIES SCHEDULE

TYPE

MARK MFR MODEL DESCRIPTION COMMENTS

AC-1 BOBRICK B-5193 SOLID PHENOLIC FOLDING SHOWER/DRESSING AREA SEAT

AC-2 BOBRICK B-2892 SURFACE MOUNTED TWIN JUMBO-ROLL TOILET TISSUE DISPENSER

AC-3 BOBRICK B-2890 SURFACE MOUNTED SINGLE JUMBO-ROLL TOILET TISSUE DISPENSER

AC-4 BOBRICK B-35303 RECESSED SANITARY NAPKIN DISPOSAL

AC-5 BOBRICK B-35139 SURFACE MOUNTED SANITARY NAPKIN DISPOSAL

AC-6 BOBRICK B-39747 RECESSED AUTOMATIC ROLL PAPER TOWEL DISPENSER AND WASTE RECEPTACLE

AC-7 BOBRICK B-3979 SURFACE MOUNTED AUTOMATIC ROLL PAPER TOWEL DISPENSER AND WASTE RECEPTACLE

AC-9 KOALA KARE KB310-SSWM BABY CHANGING STATION - SURFACE MOUNT

AC-10 KOALA KARE KB3000-AHL ADJUSTABLE HEIGHT CHANGING STATION

AC-11 AMERICAN SPECIALTIES INC 3700 GRAB BAR w/ SNAP-ON FLANGE COVERS

AC-12 BOBRICK B-1556 FRAMELESS STAINLESS STEEL MIRROR

AC-13 BOBRICK B-233 STAINLESS STEEL CLOTHES HOOK

AC-16 BRADLEY SERIES 400 SENTINEL TOILET PARTITIONS AND URINAL SCREENS

AC-17 KOALA KARE KB311-SSWM BABY CHANGING STATION - SURFACE MOUNT Available Colors: Grey with Stainless Steel

AC-18 BOBRICK B-2112 SURFACE MOUNT SOAP DISPENSER

ACT-1 TOILET ROOM CEILINGS SQUARE LAY-IN TILE ARMSTRONG DUNE TEGULAR 1774 24x24 CLASS A

CEILINGS

TL-1 WET WALLS CERAMIC TILE CREATIVE MATERIALS RAIN (COLOR AND FINISH TBD) 3x12 BULLNOSE EDGE

PT-1 WALL PAINT COLOR PAINT COLORS - TBD

WALLS

RSF-1 FLOORS RESINOUS FLOORING DUR-A-FLEX HYBRI-FLEX EQ INTEGRAL BASE

COLOR - TBD

FLOORING

TYPE MARK LOCATION DESCRIPTION MANUFACTURER PRODUCT SIZE CLASS FLAME SPREAD SMOKE DEVELOPED CONTACT COMMENTS

FINISH SCHEDULE

A14

1 TOILET ROOM FIXTURE & ACCESSORY MOUNTING LOCATIONS

GENERAL NOTES:

1. KEYED LOCATIONS ARE TO BE FOUND ON SHEETS A8, A9, A10 & A11

SHEET

OF

dlieb Rectangle dlieb Rectangle dlieb Callout

GRAB BAR AT 36" AFF MAX

1.5" SPACE BETWEEN BOTTOM OF GRAB BAR TO TOP OF ACCESSORY/DISPENSER

36" - 1.25" - 2" = 32.75" AFF TOP OF TP AND SN DISPENSERS.

TP (RED) EDGE OF TOILET; 1" SPACE BETWEEN, TO SN (BLUE)

dlieb Line dlieb Callout

BLUE - SANITARY NAPKIN DISPENSER

dlieb

RED - TP DISPENSER, B2890

FROM FACE OF GYP/CMU

2'-0" COUNTER DEPTH

1/4" GROUT

LINE

7/8"

ACTUAL TILE DEMNSION

1'-0"

M

IN

F

R O

M S

ID

E

W A

L L

/2

MIRROR

Level 1

0' - 0"

A15

'-9

CERAMIC TILE w/ BULLNOSE EDGE, TYP

FRAMELESS MIRROR

6" CERAMIC TILE BACKSPLASH. ALIGN

WITH GROUT LINE

INTEGRATED SINK. SEE

PLUMBING DWGS

CONT SEALANT

CERAMIC TILE

RESINOUS FLOORING AND

4" INTEGRATED BASE

'-4

M A

X

'-1

IN-WALL BLOCKING

AS NECESSARY

LIGHT FIXTURE. SEE ELEC

/2

ACOUSTICAL CEILING SYSTEM

ST. STEEL EDGE

1'-6"

/2

FLOOR ABOVE

DIAGONAL BRACING @ 4' O.C.

M

IN

A

B O

V E

F

IN

IS

H

E D

F L

O O

R

WALL FAUCET

7" 7"

LINEAR SLOT DIFFUSER

SUB SHEET NO.DESIGNED:

CADD:

TECH REVIEW:

DATE:

TITLE OF SHEET DRAWING NO.

PMIS SHEET

OF

NO.

99B

LOWE 475

187375

A15

RESTROOM DETAILS

NPS LOWE TOILETS

Designer

Author

Checker

05/18/2023

A15

1 COUTERTOP EDGE DETAIL

A15

2 SECTION AT LAVATORY

David Lieb Rectangle

David Lieb Line

David Lieb Line

David Lieb Line

David Lieb

EXTEND ACT FULL BATHROOM, LIGHTS AND DIFFUSER TO BE RECESSED INTO ACT

V

MPV

T

PS

F

P

P

F

FS

PP

GAS PIPING

FLOW SWITCH

EQUIPMENT TAG

AUTOMATIC AIR VENT

VENT PIPING

MULTIPURPOSE VALVE

PRESSURE SWITCH

THERMOMETER

HOT WATER PIPING

POINT OF CONNECTION TO EXISTING

DUCT STATIC PRESSURE SENSOR

VARIABLE AIR VOLUME BOXCOLD WATER PIPING

PRESSURE REGULATING VALVE

UNION

CIRCUIT BALANCE VALVE

SWING CHECK VALVE

BALL VALVE

BUTTERFLY VALVE

PRESSURE GAUGE W/PETCOCK

THERMOSTAT

GATE VALVE

MANUAL AIR VENT

HOT WATER RETURN PIPING

CHILLED WATER SUPPLY PIPING

HOT WATER SUPPLY PIPING

CHILLED WATER RETURN PIPING

HWS

HWR

CHWS

CHWR

CONDENSER WATER RETURN

CONDENSER WATER SUPPLY

CWR

CWS

PIPE DROP

PIPE RISER

PIPE TEE - DOWN

PIPE TEE - UP

PIPE CONNECTION

PIPE BREAK - TO CONTINUE

DIRECTION OF FLOW

EXISTING RECTANGULAR DUCT RUN W/ SIZE

DESIGNATION

EXISTING CIRCULAR DUCT RUN W/ SIZE DESIGNATION

DEMOLITION RECTANGULAR DUCT RUN W/ SIZE

DESIGNATION

DEMOLITION CIRCULAR DUCT RUN W/ SIZE

DESIGNATION

NEW RECTANGULAR DUCT RUN W/ SIZE DESIGNATION

NEW CIRCULAR DUCT RUN W/ SIZE DESIGNATION

NEW RECTANGULAR DUCT - UP

NEW CIRCULAR DUCT RUN - UP

NEW RECTANGULAR DUCT - DOWN

NEW CIRCULAR DUCT RUN - DOWN

EXISTING FLEX DUCT RUN W/ SIZE DESIGNATION

DEMOLITION FLEX DUCT RUN W/ SIZE DESIGNATION

NEW FLEX DUCT RUN W/ SIZE DESIGNATION

ACOUSTICALLY LINED DUCT RUN

ELEVATION CHANGE IN DUCTWORK - UP

RECTANGULAR TO RECTANGULAR DUCTWORK TRANSITION

RECTANGULAR TO CIRCULAR DUCTWORK TRANSITION

RECTANGULAR TO RECTANGULAR DUCTWORK TRANSITION

ELEVATION CHANGE IN DUCTWORK - DOWN

DUCTWORK BREAK - TO CONTINUE

RG, RR

EG, ER

SD, SR, SG

SD, SR, SG

SD, SR, SG

SD, SR, SG

SD, SR, SG

DIFFUSER, REGISTER OR GRILLE TAG, WITH CFM

AIRFLOW

NOTE CALL OUT1

COMBINATION FIRE SMOKE DAMPER

FIRE DAMPER

MANUAL VOLUME DAMPER

HUMIDIFIER

PIPE CAP

PIPE GUIDE

PIPE ANCHOR

CW

HW

V

G

REHEAT HOT WATER RETURN PIPING

REHEAT HOT WATER SUPPLY PIPINGRHWS

RHWR

REVISION TAG

REVISION CLOUD

DUCT SIZE12∅, 12x12

AD

AFF

AFG

AP

AS

ATC

BC

BFP

BOD

BTU

BTUH

C

C&HW

CAP

CC

CD

CFM

COL

CV

DB

DDC

DIA

DN

DO

DWG OR DWGS

E, EX OR (E)

EA

EAT

EC

ECU

EF

EL

EMS

ERV

ESP

ET

ETR

EWT

EXH

FA

FC

FCU

FD

FLA

FLR

FPI

FPM

FSD

FT

FTR

GAL

GC

GE

GPM

GV

HC

HP

HVAC

HW

ID

IH

IN

KW

L

LAT

LWT

MBH

MD

MECH

MTD

N.C. OR NC

N.O. OR NO

NIC

NOM

NTS

O.A. OR OA

OAT

OD

OED

PC

PD

PSI

PRV

RA

REF

RF

RHWR

RHWS

RM

RV

SA

SAT

SF

SP

SPD

SPEC

SS

TOD

TSTAT

TYP

U.G.

U.S.

UC

V

VAV

VB

VFD

VTR

W W/

WB

DUCT ACCESS DOOR

ABOVE FINISHED FLOOR

ABOVE FINISH GRADE

ACCESS PANEL

AIR SEPARATOR

AUTOMATIC TEMPERATURE CONTROL

BLOWER COIL

BACK FLOW PREVENTER

BOTTOM OF DUCT

BRITISH THERMAL UNIT

BRITISH THERMAL UNIT PER HOUR

CONVECTOR

COLD & HOT WATER

CAPACITY

COOLING COIL

CEILING DIFFUSER

CUBIC FEET PER MINUTE

COLUMN

CONTROL VALVE

DRY BULB TEMPERATURE

DIRECT DIGITAL CONTROL

DIAMETER

DOWN

DIGITAL OUTPUT

DRAWING OR DRAWINGS

EXISTING

EXHAUST AIR

ENTERING AIR TEMPERATURE

ELECTRICAL CONTRACTOR

EVAPORATIVE CONDENSING UNIT

EXHAUST FAN

EXPANSION LOOP

ENERGY MANAGEMENT SYSTEM

ENERGY RECOVERY VENTILATOR

EXTERNAL STATIC PRESSURE

EXPANSION TANK

EXISTING TO REMAIN

ENTERING WATER TEMPERATURE

EXHAUST

FREE AREA

FLEXIBLE CONNECTION

FAN COIL UNIT

FIRE DAMPER

FULL LOAD AMPS

FLOOR

FINS PER INCH

FEET PER MINUTE

COMBINATION FIRE AND SMOKE DAMPER

FEET

FIN TUBE RADIATION

GALLONS

GENERAL CONTRACTOR

GENERAL EXHAUST

GALLONS PER MINUTE

GATE VALVE

HEATING COIL

HORSE POWER

HEATING, VENTILATION AND AIR COND.

HOT WATER

INSIDE DIAMETER

INTAKE HOOD

INCHES

KILOWATTS

LOUVER

LEAVING AIR TEMPERATURE

LEAVING WATER TEMPERATURE

THOUSANDS OF B.T.U.'S PER HOUR

MOTORIZED DAMPER

MECHANICAL

MOUNTED

NORMALLY CLOSED

NORMALLY OPEN

NOT IN CONTRACT

NOMINAL

NOT TO SCALE

OUTSIDE AIR

OUTSIDE AIR TEMPERATURE

OUTSIDE DIAMETER

OPEN ENDED DUCT

PLUMBING CONTRACTOR

PRESSURE DROP

POUNDS PER SQUARE INCH

PRESSURE REDUCING VALVE

RETURN AIR

RETURN EXHAUST FAN

RETURN FAN

REHEAT WATER RETURN

REHEAT WATER SUPPLY

ROOM

RELIEF VALVE

SUPPLY AIR

SUPPLY AIR TEMPERATURE

SQUARE FEET

STATIC PRESSURE

SPEED

SPECIFICATION

STAINLESS STEEL

TOP OF DUCT

THERMOSTAT

TYPICAL

UNDER GRADE

UNDER SLAB

UNDERCUT DOOR

VENT

VARIABLE AIR VOLUME

VACUUM BREAKER

VARIABLE FREQUENCY DRIVE

VENT THROUGH ROOF

WASTE

WITH

WET BULB TEMPERATURE (°F)

HOT WATER RETURN PIPINGHWR

GLOBE VALVE

FLANGE

STRAINER W/DRAIN VALVE AND CAP

PRESSURE PORT ("PETE'S PLUG")

CHEMICAL SUPPLY PIPESCHEM

SANITARY DRAIN ABOVE FLOOR OR GRADESAN

HIGH-TEMPERATURE HOT WATER RETURNHTWR

MEDIUM-TEMPERATURE HOT WATER RETURNMTWR

FUEL OIL TANK VENTFOV

HIGH-TEMPERATURE HOT WATER SUPPLYHTWS

MEDIUM-TEMPERATURE HOT WATER SUPPLYMTWS

FUEL OIL RETURNFOR

FUEL OIL SUCTIONFOS

FUEL OIL GAGEFOG

FUEL OIL DISCHARGEFOD

BOILER BLOWDOWNBBD

HIGH-PRESSURE CONDENSATEHPC

PUMPED CONDENSATEPC

MAKE UP WATERMUW

A.C. CONDENSATE DRAIND

REFRIGERANT HOT GASRHG

RL

RS

GLYCOL RETURNGR

REFRIGERANT LIQUID

REFRIGERANT SUCTION

GLYCOL SUPPLYGS

HWS

HWR

CHWS

CHWR

CWR

CWS

RHWS

RHWR

CHEM

SAN

HTWR

MTWR

FOV

HTWS

MTWS

FOR

FOS

FOG

FOD

BBD

HPC

PC

MUW

D

RHG

RL

RS

GR

GS

BLV

BFV

SCV

CBV

ACV

ACV

GV

GLV

MPV

PRV

T

FLG

RSV

PGV

RPBP

RELIEF OR SAFETY VALVE

PLUG VALVE

REDUCED PRESSURE BACKFLOW PREVENTER

S-1

VAV

RETURN AIR GRILLE, REGISTER

EXHAUST AIR GRILLE, REGISTER

SUPPLY AIR 4 WAY DIFFUSER, REGISTER, GRILLE

SUPPLY AIR 3 WAY DIFFUSER, REGISTER, GRILLE

SUPPLY AIR 2 WAY DIFFUSER, REGISTER, GRILLE

SUPPLY AIR 2 WAY DIFFUSER, REGISTER, GRILLE

SUPPLY AIR 1 WAY DIFFUSER, REGISTER, GRILLE

ANCHOR

GUIDE

U

1. ALL HVAC GENERAL NOTES, SYMBOLS LISTS & DETAILS ARE TO BE

CONSIDERED AS APPLICABLE TO ALL HVAC DRAWINGS FOR THIS

PROJECT.

2. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND EXACT LOCATIONS

AND ARRANGEMENTS OF EXISTING/NEW EQUIPMENT, DUCTWORK,

PIPING AND OTHER COMPONENTS SHALL BE DETERMINED IN THE FIELD

WITH DUE CONSIDERATION OF STRUCTURAL, ELECTRICAL AND

ARCHITECTURAL SYSTEMS. EXISTING STRUCTURAL SYSTEMS SHALL

NOT BE MODIFIED WITHOUT THE EXPRESS PERMISSION OF THE

ENGINEER.

3. THE PROJECT SHALL BE PHASED IN ACCORDANCE WITH THE

CONTRACTOR'S APPROVED PHASING PLAN. THE CONTRACTOR SHALL

OBTAIN APPROVAL FROM THE OWNER FOR THE SEQUENCING AND

TIMING OF OPERATIONS PRIOR TO COMMENCING WORK. SEE

SPECIFICATIONS.

4. CONTRACTOR IS TO MAINTAIN SERVICE TO ROOMS OUTSIDE THE

PROJECT SCOPE OF WORK AND PHASING SCHEDULE. IF INTERRUPTION

OF SERVICE IS REQUIRED, COORDINATE SHUTDOWN WITH THE OWNER.

NOTIFY THE OWNER A MINIMUM OF 96 HOURS PRIOR TO SHUTDOWN.

5. CARE SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT EXISTING

SYSTEMS AND SURFACES TO REMAIN. RESTORE DAMAGED AREAS THAT

ARE BEYOND THE SCOPE OF THIS CONTRACT TO THEIR ORIGINAL

CONDITION.

6. WHERE INDICATED ON THE DRAWINGS, REMOVE OR RELOCATE

EXISTING COMPONENTS AS REQUIRED TO ACCOMMODATE THE NEW

WORK. REMOVALS SHALL INCLUDE ALL ASSOCIATED OFF-SITE DISPOSAL

COSTS.

7. COORDINATE REMOVALS AND RELOCATIONS INCLUDING SELECTIVE

CUTTING AND PENETRATIONS WITH ARCHITECTURAL, MECHANICAL,

STRUCTURAL AND ELECTRICAL CONTRACTORS.

8. ALL PARTITIONS ARE FULL HEIGHT AND REQUIRE UTILITIES

PENETRATIONS TO BE SEALED. UTILITIES SHOWN FOR CLARITY THAT

MAY RUN PARALLEL TO WALL PARTITIONS WILL REQUIRE LOCATING IN

THE FIELD TO MINIMIZE CONFLICT WITH PARTITIONS.

9. COORDINATE THE LOCATIONS OF ALL WALL MOUNTED TEMPERATURE

SENSORS WITH FINAL EQUIPMENT/FURNITURE LAYOUT.

10. PROVIDE SEISMIC RESTRAINTS PER SPECIFICATION 130541.

11. MANUFACTURERS NAME & MODEL NUMBER ARE USED FOR DESCRIPTIVE

PURPOSES ONLY & ARE INTENDED TO INDICATE THE STANDARD OF

MATERIAL OR ARTICLES REQUIRED.

12. INSTALL EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER'S

RECOMMENDATIONS AND GOOD PRACTICE NORMAL TO THE TRADE.

INSTALLATION SHALL INCLUDE PROVISIONS FOR ACCESS TO NORMAL

MAINTENANCE ITEMS SUCH AS BELTS, BEARINGS, FILTERS AND

MOTORS. PROVIDE ADEQUATE STRUCTURAL SUPPORTS AND SECURE

MOUNTING METHODS WITH PROVISIONS FOR VIBRATION ISOLATION AND

EXPANSION WHERE REQUIRED.

13. PROVIDE VOLUME DAMPERS AT EACH BRANCH FROM MAIN DUCTWORK

AND DUCT RUNNOUTS TO AN INDIVIDUAL REGISTER OR DIFFUSER IN

SUPPLY, RETURN AND EXHAUST DUCTS IRRESPECTIVE OF WHETHER OR

NOT A DAMPER IS INDICATED ON THE PLANS.

14. DIFFUSER SIZES INDICATED ARE NECK SIZES. REGISTERS & GRILLES

ARE INDICATED AS NOMINAL SIZES.

15. PERFORM ALL TESTS BEFORE INSULATING. PERFORM ALL PRESSURE

TESTING AND CLEAN DUCTWORK/PIPING PRIOR TO INSULATION.

16. PIPING AND DUCTWORK SHALL BE CONCEALED UNLESS OTHERWISE

NOTED.

17. INSTALLATION SHALL PERMIT ACCESSIBILITY FOR SERVICE AND/OR

REPLACEMENT OF EQUIPMENT PROVIDED. PROVIDE ACCESS PANELS TO

GAIN ACCESS TO SYSTEMS COMPONENTS THAT REQUIRE MAINTENANCE

ACCORDING TO MANUFACTURER'S LITERATURE.

18. PROVIDE DUCTWORK WITH OFFSETS AND TRANSITIONS AS REQUIRED

TO FIT UNDER STRUCTURAL STEEL OR OTHER OBSTRUCTIONS. FLAT

OVAL OR ROUND SIZES MAY BE USED INTERCHANGEABLY BY THE

CONTRACTOR. MAINTAIN DUCT CROSS SECTIONAL AREA. CHANGES

SHALL BE ONLY IN ACCORDANCE WITH APPROVED SHOP DRAWINGS OR

WRITTEN PERMISSION OF THE PROJECT ENGINEER.

19. PROVIDE CLAMPS, OFFSETS, EXPANSION JOINTS, ANCHORS & GUIDES

AS NECESSARY TO PREVENT UNDUE STRAIN ON PIPING.

20. SEE DETAILS & PIPING DIAGRAMS FOR ADDITIONAL VALVES & FITTINGS

NECESSARY FOR COMPLETE PIPING SYSTEM.

21. MECHANICAL CONTRACTOR TO COORDINATE ALL WORK WITH OTHER

BUILDING TRADES. SOME RELOCATION OF EXISTING UTILITIES MAY BE

NECESSARY TO ACCOMMODATE INSTALLATION OF NEW EQUIPMENT OR

DUCTWORK.

22. PROVIDE FIRE OR FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS

& WHERE REQUIRED BY APPLICABLE CODES FOR DUCTS & OPENINGS

THROUGH FLOORS, FIRE WALLS & FIRE PARTITIONS. DAMPERS SHALL BE

ENCLOSED IN #14 GAUGE STEEL SLEEVE. PROVIDE ACCESS DOORS

LOCATED SO THAT FUSIBLE LINK & OTHER DAMPER COMPONENTS MAY

BE INSPECTED REPLACED AND/OR SERVICED.

23. SEE SPECIFICATIONS FOR OTHER REQUIREMENTS.

24. AT THE END OF EACH WORKING DAY, THE CONSTRUCTION SITE SHALL

BE LEFT IN A CLEAN AND NEAT CONDITION.

25. FILL AND PATCH ALL OPENINGS IN WALLS WHERE CONDUITS, PIPES,

DUCTS ETC. ARE OR HAVE BEEN REMOVED WITH UL LISTED FIRE

ASSEMBLY APPROVED BY THE ARCHITECT. MAINTAIN 2 HR FIRE RATING

WHERE APPLICABLE.

26. TIE-IN POINT LOCATIONS ARE APPROXIMATE. CONTRACTOR SHALL

DETERMINE EXACT LOCATIONS IN THE FIELD BASED ON EXISTING

CONDITIONS.

27. EQUIPMENT ARRANGEMENT, DUCTWORK SIZES, PENETRATIONS AND

DETAILS ARE BASED ON EQUIPMENT SCHEDULED. CONTRACTOR SHALL

ADJUST SIZES AND ROUTING AS REQUIRED TO ACCOMMODATE ACTUAL

EQUIPMENT INSTALLED.

28. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HANDLING, STORAGE

AND SETTING OF ALL EQUIPMENT AND MATERIAL. CRANES, LIFTS,

HOISTS, AND SCAFFOLDING OF ALL EQUIPMENT SHALL BE EMPLOYED AS

REQUIRED TO COMPLETE THE INSTALLATION.

SMOKE DAMPER

3-WAY AUTOMATIC CONTROL

VALVE (MIXING PATTERN)

2-WAY AUTOMATIC CONTROL VALVE

SHADED DUCTWORK SHALL BE 16 GAUGE SHEETMETAL10x16

ROOF EXHAUST - EXISTING

ROOF EXHAUST - REMOVED

ROOF EXHAUST - NEW

EXPANSION JOINT

PIPE SIZE12"

G

PIPE SLOPE

PIPE SIZE, GANG

12"S UP

14"DN

1-1/2"

F&T

FLOAT & THERMOSTATIC TRAP

SYMBOLS DESCRIPTIONSABBREVIATIONS DESCRIPTIONSSYMBOLSSYMBOLS DESCRIPTIONSDESCRIPTIONSABBREVIATIONS SYMBOLS DESCRIPTIONS

SYMBOLS DESCRIPTIONSABBREVIATIONS

TITLENUMBER

DIFFUSER SYMBOLS

MECHANICAL LIST

DUCTWORK SYMBOLSGENERAL SYMBOLSPIPING SYMBOLSGENERAL ABBREVIATIONSHVAC GENERAL NOTES

POINT OF DISCONNECTION FROM EXISTING

V

S

T REMOTE TEMPERATURE AND HUMIDITY DISPLAYH

M ROOM TEMPERATURE, HUMIDITY AND DIFFERENTIAL

PRESSURE ALARM/DISPLAY MONITOR

M MANUAL PURIFIER (P-1) ACTIVATION SWITCH

NOTES

M1 MECHANICAL GENERAL NOTES AND LEGNEDS

M2 MECHANICAL DEMOLITION PLAN

M3 MECHANICAL MOGAN DEMOLITION PLAN

M4 MECHANICAL NEW PLAN

M5 MECHANICAL MOGAN NEW PLAN

SUB SHEET NO.DESIGNED:

CADD:

TECH REVIEW:

DATE:

TITLE OF SHEET DRAWING NO.

PKG SHEET

OF

NO.M1

MECHANICAL GENERAL

NOTES AND LEGEND

NPS LOWE TOILETS

PIIK

RISINGER

DESPOTOVICH

05/18/2023

99B

NOTE: NOT ALL SYMBOLS AND

ABBREVIATIONS ARE USED

3 3

MEN'S

TOILET

MCC 218

WOMEN'S

TOILET

MCC 219

2 2

MEN'S

TOILET

MCC 113

WOMEN'S

TOILET

MCC 114

SUB SHEET NO.DESIGNED:

CADD:

TECH REVIEW:

DATE:

TITLE OF SHEET DRAWING NO.

PKG SHEET

OF

NO.M3

MECHANICAL MOGAN

DEMOLITION PLAN

NPS LOWE TOILETS

Designer

Author

DESPOTOVICH

05/18/2023

99B

1/4" = 1'-0"M3

2 MOGAN CULTURAL CENTER - 2ND FLOOR MECH DEMO

1/4" = 1'-0"M3

1 MOGAN CULTURAL CENTER - 1ST FLOOR MECH DEMO

KEYNOTES

REMOVE EXISTING EXHAUST FAN1

2 REMOVE EXISTING EXHAUST GRILLE

3 EXISTING TO REMAIN CABINET UNIT HEATER

0' 2' 4' 8'

GENERAL NOTE:

LEAVE EXISITNG DUCTWORK IN PLACE TO BE REUSED,

EXCEPT WHERE NOTED TO BE REMOVED

FE

BC

FCU

4"⌀

EF 75 CFM MIN

(TYP OF 6)

10"X3-1/2" DOWN. CUT HOLE IN FLOOR.

TERMINATE OPEN END DUCT WITH SS WMS (TYP)

SUPPLY DIFFUSER

BOTTOM OF DUCT

150 CFM (TYP OF 6)

12"X12" TRANSFER

DUCT (VIF)

42"X24" GRILLE

(VIF)

4"⌀

4"⌀

EF-4 IN-LINE EF

50 CFM MIN.

4"⌀ 4"⌀ 4"⌀ 4"⌀

2 2

MECHANICAL

BCH 107

LOBBY

STORAGE

CLOSET

BCH 106

UNISEX

TOILET

BCH 105

UNISEX

TOILET

BCH 104

UNISEX

TOILET

BCH 103

UNISEX

TOILET

BCH 102

UNISEX

TOILET

BCH 101

FAMILY

RESTROOM

BCH 100

EF3 EF3 EF3EF3EF3EF3

16X8(E) 28X8(E)

22X8(E)

NEW EXHAUST

GRILLE

PLENUM

T

PROVIDE OFFSET UP IN DUCTWORK. (TYP) SEE KEYNOTE 2

MEN'S

TOILET

ROOM

VC 007

WOMEN'S

TOILET

ROOM

VC 008

UNISEX

TOILET

VC 005

TOILET

VC 111

UTILITY

CLOSET

VC 108

TOILET

VC 109

EF2

EXHAUST DUCT

(SEE PLAN FOR SIZE)

EXHAUST FAN

OPTION CEILING CEILING GRILLE

EXHAUST FAN DETAIL

WALL SUPPORT FROM

STRUCTURE ABOVE

SUPPORT ANGLE

TYPE B

8'-0" O.C.

4'-0" O.C.

1 1/2"x1 1/2"x1/8"3/8"

USE 1"x1/8"

25" TO 36"

UP TO 24"

(OR WELD STUD)

BLIND RIVETS

TYPE

A

DUCT WIDTH

HANGER RODS

SOLID BANDS

NON-GMP SYSTEMS: ALL FAN COIL UNITS

NOTE: ALL INSULATED DUCTWORK SHALL HAVE THERMAL BREAK AT EACH

DUCT SUPPORT.

ROD

DIAMETER

TYPE

SUPPORT ANGLE MAX

SPACING

NON-GMP

SYSTEMS

B

A

INSULATION

1 1/2"x1 1/2"x1/8"

DUCT HANGER DETAIL AND SCHEDULE

COLD PIPE

(VAPOR BARRIER)

WITH INSULATION

PIPE

WITHOUT INSULATION

HOT PIPE

(NO VAPOR BARRIER)

WITH INSULATION

INSULATION O.D.

CLEVIS HANGER

HANGER ROD

RIGID INSULATION

SHEETMETAL SHIELD

PIPE

NUT

PIPE

PIPE O.D.

CLEVIS HANGER

HANGER ROD (TYPICAL)

SHEETMETAL SHIELD

RIGID INSULATION

NUTNUT

PIPE HANGER DETAIL - CLEVIS TYPE

SUB SHEET NO.DESIGNED:

CADD:

TECH REVIEW:

DATE:

TITLE OF SHEET DRAWING NO.

PKG SHEET

OF

NO.M4

MECHANICAL NEW PLAN

NPS LOWE TOILETS

PIIK

RISINGER

DESPOTOVICH

05/18/2023

99B

1/4" = 1'-0"M4

2 BOOTT COUNTING HOUSE - LEVEL 1 MECH1/4" = 1'-0"M4

4 VISITOR CENTER - GROUND FLOOR MECH

1/4" = 1'-0"M4

5 VISITOR CENTER - 1ST FLOOR MECH

KEYNOTES

PROVIDE NEW LINEAR SLOT DIFFUSER. CONNECT TO

EXISTING SUPPLY DUCT

PROVIDE NEW EXHAUST FAN. OFFSET BRANCH

CONNECTIONS, BULLHEAD CONFIGURATION NOT ALLOWED

PROVIDE NEW EXHAUST FAN. CONNECT TO EXISTING

EXHAUST AIR SYSTEM

REBALANCE FCU TO NEW DESIGN AIRFLOW

REFURBISH EXISTING EQUIPMENT. CLEAN

WASHABLE/REPLACE REPLACEABLE AIR FILTERS,

REPLACE BELTS, CLEAN COILS, GREASE BEARINGS

7 RE-INSTALL EXISTING THERMOSTAT AND WIRE TO EXISTING

FCU

5 ROUTE TRANSFER DUCTS ABOVE THE EXISTING SUPPLY,

ON EITHER SIDE OF EXISTING SPRINKLER PIPE. PROTECT

OPENING WITH WMS

8 PROVIDE NEW EXHAUST GRILLE. CONNECT TO EXISTING

EXHAUST SYSTEM

0' 2' 4' 8'

NOTES:

1. PROVIDE FLEXIBLE CONNECTIONS ON THE INLET AND OUTLET CONNECTIONS OF FAN RO DUCTWORK

2. PROVIDE 120VAC TO 24VDC TRANSFORMER

3. PROVIDE FACTORY MOUNTED NEMA-1 DISCONNECT SWITCH

4. UNIT SHALL OPERATE AS INDEXED BY WALL MOUNTED PROGRAMMABLE TIME-CLOCK DURING OCCUPIED HOURS

5. PROVIDE GRAVITY BACKDRAFT DAMPER

6. PROVIDE FACTORY VIBRATION ISOLATION KIT

1,2,3,4,5,6

EF 4 BOOTT/JANITOR 50 0.5 OCCUPANCY INLINE 2,083 0.05 .15 2,083 DIRECT 120 1.3 1 8 CAPTIVEAIRE DFA-100-CA 1,2,3,4,5,6

EF 3 BOOTT/RESTROOM 75 0.26 OCCUPANCY CEILING 900 0.01 .01 900 DIRECT 120 0.17 1 12 GREENHECK SP-A90 1,2,3,4,5,6

EF 2 VISITOR/RESTROOM 75 0.26 OCCUPANCY CEILING 900 0.01 .01 900 DIRECT 120 0.17 1 12 GREENHECK SP-A90 1,2,3,4,5,6

EF 1 MOGAN/RESTROOM 140 0.5 OCCUPANCY CEILING 648 0.11 .17 648 DIRECT 120 2.3 1 23 CAPTIVEAIRE CFA-200-CA 1,2,3,4,5,6

MARK #

BUILDING/AREA

SERVED

TYPE

SPEED

(RPM)

BHP HP

SPEED

(RPM)

DRIVE

TYPE

VOLTS MCA PHASE

UNIT IDENTIFICATION

AIRFLOW

(CFM)

ESP

(IN-WG)

CONTROL

FAN WHEEL FAN MOTOR ELECTRICAL

OPERATING

WEIGHT

(LBS.)

MANUFACTURER

MODEL

NUMBER

NOTES

EXHAUST FAN SCHEDULE

9 EXISTING BLOWER COIL (BC) AND EXISTING FAN COIL UNIT

(FCU)

David Lieb Line

David Lieb Line

David Lieb Line

3 3

MEN'S

TOILET

MCC 113

WOMEN'S

TOILET

MCC 114

EF1EF1

2 2

4 4

MEN'S

TOILET

MCC 218

WOMEN'S

TOILET

MCC 219

SUB SHEET NO.DESIGNED:

CADD:

TECH REVIEW:

DATE:

TITLE OF SHEET DRAWING NO.

PKG SHEET

OF

NO.M5

MECHANICAL MOGAN NEW

PLAN

NPS LOWE TOILETS

PIIK

RISINGER

DESPOTOVICH

05/18/2023

99B

1/4" = 1'-0"M5

1 MOGAN CULTURAL CENTER - 1ST FLOOR MECH

1/4" = 1'-0"M5

2 MOGAN CULTURAL CENTER - 2ND FLOOR MECH

KEYNOTES

PROVIDE NEW EXHAUST FAN1

2 COORDINATE FOR NEW LOUVERS IN NEW DOORS FOR 0.75

SQ.FT. SEE ARCH PLANS FOR COLOR/FINISH

3 PROVIDE NEW EXHAUST GRILLE. CONNECT TO EXISTING

DUCT. BALANCE TO 100 CFM MIN

4 EXISTING TO REMAIN CABINET UNIT HEATER. COORDINATE

WITH NEW CEILING

0' 2' 4' 8'

T

PS

F

P

MPV

FLOW SWITCH

AUTOMATIC AIR VENT

WATER HAMMER ARRESTOR

VENT PIPING

PRESSURE SWITCH

DOMESTIC HOT WATER PIPING

POINT OF CONNECTION TO EXISTING (TIE-IN POINT)

DOMESTIC COLD WATER PIPING

PRESSURE GAUGE W/PETCOCK

THERMOMETER W/IMMERSION WELL

MANUAL AIR VENT

DOMESTIC HOT WATER RECIRCULATION PIPINGDHWR

1. ALL PLUMBING GENERAL NOTES, SYMBOLS, LISTS AND DETAILS ARE TO BE

CONSIDERED AS APPLICABLE TO ALL PLUMBING DRAWINGS FOR THIS

PROJECT.

2. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND EXACT LOCATIONS

AND ARRANGEMENTS OF EXIST./NEW EQUIPMENT, DUCTWORK, PIPING

AND OTHER COMPONENTS SHALL BE DETERMINED IN THE FIELD WITH DUE

CONSIDERATION OF STRUCTURAL, ELECTRICAL AND ARCHITECTURAL

SYSTEMS. EXISTING STRUCTURAL SYSTEMS SHALL NOT BE MODIFIED

WITHOUT THE EXPRESS PERMISSION OF THE ENGINEER.

3. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE PROJECT ENGINEER

FOR THE SEQUENCING AND TIMING OF OPERATIONS PRIOR TO COMMENCING

WORK. SEE SPECIFICATIONS.

4. CONTRACTOR IS TO MAINTAIN SERVICE TO ROOMS OUTSIDE THE PROJECT

SCOPE OF WORK. IF INTERRUPTION OF SERVICE IS REQUIRED COORDINATE

SHUTDOWN WITH PROJECT ENGINEER.

5. CARE SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT EXISTING

SYSTEMS AND SURFACES TO REMAIN. RESTORE DAMAGED AREAS THAT ARE

BEYOND THE SCOPE OF THIS CONTRACT TO THEIR ORIGINAL CONDITION.

6. WHERE INDICATED ON THE DRAWINGS, REMOVE OR RELOCATE EXISTING

COMPONENTS AS REQUIRED TO ACCOMMODATE THE NEW WORK.

REMOVALS SHALL INCLUDE ALL ASSOCIATED OFF-SITE DISPOSAL COSTS.

7. COORDINATE REMOVALS AND RELOCATION'S INCLUDING SELECTIVE CUTTING

AND PENETRATIONS WITH ARCHITECTURAL, MECHANICAL, STRUCTURAL AND

ELECTRICAL CONTRACTORS.

8. MOST PARTITIONS ARE FULL HEIGHT AND REQUIRE UTILITIES PENETRATIONS

TO BE SEALED, SEE ARCHITECTURAL DWGS FOR PARTITION HEIGHTS.

DUCTWORK SHOWN FOR CLARITY THAT MAY RUN PARALLEL TO WALL

PARTITIONS WILL REQUIRE LOCATING IN THE FIELD TO MINIMIZE CONFLICT

WITH PARTITIONS.

9. FIELD VERIFY EXISTING EQUIPMENT AND PIPING PRIOR TO REMOVAL OR

REUSE. CONFIRM WITH PROJECT ENGINEER THAT ALL EQUIPMENT AND

PIPING DESIGNATED TO BE REMOVED IS NO LONGER IN SERVICE PRIOR

TO ITS REMOVAL. PROJECT ENGINEER SHALL HAVE FIRST RIGHT OF

REFUSAL ON ALL DEMO'D EQUIPMENT.

10. EXISTING EQUIPMENT AND PIPING TO REMAIN IN SERVICE SHALL BE

INSPECTED, REPORT INOPERABLE EQUIPMENT TO PROJECT ENGINEER.

11. ALL UNUSED (ABANDONED), PIPING AND EQUIPMENT INDICATED TO BE

REMOVED SHALL BE…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .