This document is a comprehensive product catalog containing technical specifications and ordering information for fire alarm systems, detection devices, notification appliances, surge protection equipment, and supporting components manufactured by Honeywell Silent Knight, System Sensor, Notifier, and associated suppliers.

The catalog includes detailed specifications for addressable fire alarm control panels (6700, 5860 remote annunciators), intelligent smoke detectors (SK-PHOTO-W Series photoelectric, SK-FIRE-CO-W multi-criteria fire/CO detector), monitor modules (SK-MONITOR), pull stations (SK-PULL-SA/DA), audible-visible notification devices (L-Series horns and strobes with LED technology, SpectrAlert Advance outdoor devices), power modules (5496 intelligent power expander), and related accessories. Technical specifications include operating voltage ranges (typically 15-32 VDC for panels and devices, 120VAC for some components), current draw ratings, environmental operating temperatures (-40°F to 151°F depending on product), humidity ranges, and dimensional data. The catalog also covers supporting infrastructure including rechargeable sealed lead acid batteries (PS-12100 12V/12AH), fire alarm document storage cabinets (NF-FAD), surge protection devices (DTK-DF120S1 for 120VAC loads, CLC series for current loop protection, S-SPT series for AC units), and multi-conductor shielded fire alarm cables (E2482S through E2544S, NEC Type FPLR/CL3R/CMR compliant). All products carry UL, FM, CSFM, CSA, or equivalent agency listings and approvals. Ordering information and compatible accessory options are provided throughout, with contact information for Honeywell Silent Knight (12 Clintonville Road, Northford, CT 06472, 800-328-0103) and System Sensor listed for technical support and additional product inquiries.

View the file

Other files for this federal contract opportunity

Other files attached to LAKE26-0039-PARA FIRE SUPRESSION SYSTEM, newest first.
File Type Posted
B09_Amd_0001_Atch_1_-_Specifications_Revision_0001.pdf PDF
Sol_140P8126R0002_Amd_0001.pdf PDF
B08_Atch_4_-_Dellenbaugh_Transportation_Map.pdf PDF
B08_Atch_9_-_Past_Performance_Questionnaire.docx DOCX document
B08_Atch_5_-_Construction_Wage_Determination_5_18_26.pdf PDF
B08_Atch_6_-_Proposal_Submission_Cover_Page___ToC.docx DOCX document
Sol_140P8126R0002.pdf PDF
B08_Atch_10_-_Key_Personnel___Trades_Form.docx DOCX document
B08_Atch_11_-_SF_24_Bid_Bond.pdf PDF
B08_Atch_12_-_52_209-7_Response_Form.docx DOCX document
B08_Atch_13_-_52_209-13_Response_Form.docx DOCX document
B08_Atch_1_-_Specifications.pdf PDF
B08_Atch_8_-_Project_Experience_Questionnaire.docx DOCX document
B08_Atch_14_-_General_References_Form.docx DOCX document
B08_Atch_15_-_Subcontracting_Percentage_Worksheet.xlsx XLSX spreadsheet
B08_Atch_2_-_Drawings.pdf PDF
B08_Atch_7_-_Price_Schedule.xlsx XLSX spreadsheet
Show all 17

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

• Capable of providing up to 100 points to satisfy smaller installation needs

• Connect up to 17 panels on one site with convenient single-point access using the SK-NIC Network Interface Card.

Connected panels can have mixed compatible FACP models

• Convenient field-upgradeable firmware

• 6860 annunciator with a 4 x 40 large display

• Built-in USB interface for convenient and quick programming

• Programmable date setting for automatic and convenient Daylight Saving Time changes

• 125 software zones and 125 output groups for flexible design options

The 6700 is an addressable fire alarm control panel (FACP) can be configured to panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for fi

• General Alarm (Red)

• Supervisory (Yellow):

• System Trouble (Yellow)

• System Silenced (Yellow)

• System Power (Green):

USER INTERFACE

s fi l fi fi

PROGRAMMING

SOFTWARE TOOLS

SKST:

HFSS:

ADDITIONAL INFORMATION

• UL Listed:

• CSFM

• FDNY

ORDERING INFORMATION

COMPATIBLE ANNUNCIATORS

6860: e fi

5860: e fi

6855: e fi

5865-3 or 5865-4:

5880:

m fl

SIGNAL LINE CIRCUIT (SLC)

INDICATOR LIGHTS

6700 COMPATIBLE DEVICES AND

ACCESSORIES

Important:

Page 2 of 4 — 351607:B 9/26/2018

DEVICES

SK-ACCLIMATE:

SK-BEAM:

SK-BEAM-T:

SK-CONTROL:

SK-CONTROL-6:

SK-DUCT:

SK-FIRE-CO:

SK-HEAT:

SK-HEAT-ROR:

SK-HEAT-HT:

SK-ISO:

SK-MINIMON:

SK-MONITOR:

SK-MONITOR-2:

SK-MON-10:

SK-PHOTO:

SK-PHOTO-T:

SK-PHOTOR:

SK-PULL-SA:

SK-PULL-DA:

SK-RELAY:

SK-RELAY-6:

SK-RELAYMON-2:

SK-ZONE:

SK-ZONE-6:

B210LP:

B501:

B200S:

B200S-LF:

B224RB:

B224BI:

SD COMPATIBLE ADDRESSABLE

DEVICES

SD505-6AB:

SD505-6IB:

SD505-6RB:

SD505-6SB:

SD500-AIM:

SD500-ANM: tifi

SD500-ARM:

SD505-DTS-K:

SD505-DUCT:

SD505-DUCTR:

SD505-HEAT:

SD500-LIM:

SD500-MIM:

SD505-PHOTO:

SD500-PS/-PSDA:

SD500-SDM:

AUDIBLE/VISIBLE DEVICES

CHSRL/CHSWL:

CHSCRL/CHSCWL:

CHRL/CHWL:

HRL/HWL:

P2RL/P2WL:

PC2RL/PC2WL:

SRL/SWL:

SCRL/SCWL:

SPSCRL/SPSCWL:

SPSRL/SPSWL:

SPRL/SPWL:

SPCRL/SPCWL:

SWIFT WIRELESS DEVICES

SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices.

WSK-PHOTO-T:

WSK-HEAT:

WSK-HEAT-ROR:

WSK-MONITOR:

WSK-RELAY:

W-USB:

SBUS ACCESSORIES

5496:

5883:

5824:

5895XL:

5815RMK:

COMMUNICATION OPTIONS

CELL-CAB-SK:

CELL-MOD:

IPGSM-4G:

SK-IP-2:

MISC. ACCESSORIES

SK-NIC:

SK-NIC-KIT:

SK-FML:

SK-FSL:

RBB:

SK-SCK:

PHYSICAL

Overall Dimensions:

Weight:

Color:

ENVIRONMENTAL

Operating Temperature:

Humidity:

ELECTRICAL

6700 Primary AC:

Standby Current:

Alarm Current:

Battery Charging Capacity:

Battery Size:

Honeywell Silent Knight

NOTIFICATION APPLIANCE CIRCUITS (NACS)

Two programmable circuits which can be programmed individually as:

NACs:

Auxiliary Power Circuits:

fi

WIRING:

�-��������./0#�1�/2-/��,��$���+����%�������� �$��

�/* ,���+,����3*���$�,*��*���,+�3*��� ���1�4�� �5����!�6��%��*���$������*���!�����3�7��* ��6��,����7�,����,*���� �8�6��/���*���5�� �96���������$�����,����:���:��!��,�,� �9��,33,������%���$:���$:����* ��,�4����+�;�+�,3������,$��,�� �$���+,������������:$��$���$������<�=������!

�9��� ���*�����,����,��>���>:����?����!

����:�����! ����*��,$��3����������������,�3�$�*6���+,���!���3��������$������$��$:

@ABCDEFGHE�IJJKJLMNHGOPQE�RSTU�OEFGHE�NJJKJLMNHGOV�LNJ�WE�KXEY�HG�GZEONHE�NJY�ZOG[ONF�\GJE]̂E__�̀M_EJH�aJM[QH�bOE�N_NOF�LGJHOG_�ZNJE_X�cdIefXg�hOGF�NJ]̂ QEOE�M̂HQMJ�HQE�X]XHEFi�PQE�RSTU�hENHKOEX�MJL_KYE�NJ�SUjLQNONLHEO�WNLk_MH�lem�ZOGnMYMJ[�ENX]jHG�KJYEOXHNJY�X]XHEF�FEXXN[EXi�PQE�NJJKJLMNHGO�MX�EO[GJGFMLN__]�YEXM[JEY�M̂HQ�GnEOjXMoEY�WKHHGJX�hGO�HQE�FGXH�hOEpKEJH_]�KXEY�hENHKOEXV�_MkE�DEXEH�NJY�̀M_EJLEiqJ�NYYMHMGJ�HG�XHNHKX�FEXXN[EX�YMXZ_N]EY�GJ�HQE�lemV�HQEOE�NOE�bnE�lrmX�hGO�N_NOFV�XKZEOnMXGO]V�HOGKW_EV�XM_EJLEV�NJY�Ie�ZĜ EO�XHNHKXiPQE��RSTU�NJJKJLMNHGO�MX�NnNM_NW_E�MJ�[ON]�HG�FNHLQ�nMOHKN__]�NJ]�YELGO�NJY�OEY�hGO�NZZ_MLNHMGJX�̂QEOE�HQE�NJJKJLMNHGO�FKXH�XHNJY�GKHi�PQE�NJJKJLMNHGO�EJL_GXKOE�LNJ�WE�XKOhNLE�GO�sKXQ�FGKJHEYi�I�HOMF�OMJ[�kMH�MX�NnNM_NW_E�hGO�XKOhNLE�FGKJHMJ[ituvwxyz{z|zy}~�����������������������������������������������������������������������������IYYOEXXNW_E�bOE�N_NOF�LGJHOG_�ZNJE_�̂MHQ�KZ�HG��V��U�NYYOEXXNW_E�ZGMJHX���������IYYOEXXNW_E�bOE�N_NOF�LGJHOG_�ZNJE_�̂MHQ�NJ�EFEO[EJL]�LGFFKJMLNHMGJ�X]XHEFX�NJY�KZ�HG��V��U�NYYOEXXNW_E�ZGMJHX������IYYOEXXNW_E�bOE�N_NOF�LGJHOG_�ZNJE_�̂MHQ�KZ�HG�� S�NYYOEXXNW_E�ZGMJHX�¡����IYYOEXXNW_E�bOE�N_NOF�LGJHOG_�ZNJE_�̂MHQ�KZ�HG��UU�NYYOEXXNW_E�ZGMJHX����¢£��IYYOEXXNW_E�bOE�N_NOF�LGJHOG_�ZNJE_����¢£¤�����IYYOEXXNW_E�bOE�N_NOF�LGJHOG_�ZNJE_�̂MHQ�NJ�EFEO[EJL]�LGFFKJMLNHMGJ�X]XHEFX������IYYOEXXNW_E�bOE�N_NOF�LGJHOG_�ZNJE_�¡����IYYOEXXNW_E�bOE�N_NOF�LGJHOG_�ZNJE_ ¥¦§̈ �©�¥¦§̈ ª

��
������������������
�0��
����������0��#��1'�

����2� �����3 �2 �� �������2���

���2������2���������������2�4������ ��������2��� 52�� #�6 � �&��'�2������� #�����1 �'���� �+2��������� �899:;;<:<;;;#

=8<9�1 >?@ABCDEFGHIJKGLJKM�N#OP%�Q�R#;P.�Q�O#=PS�TUV#O%�Q�O8#8.�Q�V#8S���WXYGZZGJ[�\IG[Y]M�U#8� 3 �TO#V�)�WL̂_L̀M�=8<9ab�a �c�=8<9b�d��/efgBhifjefkDE�lZÌm]GJ[�nIHZÌm]òIM�VUp�����OU9p��T9p*����;Np*WqoHGrG]sM�O9t�4�NVt����4���� ���WeEeCkhBCDElZÌm]GJ[�uL_]m[IM�U;vS*X]mJrws�̂ò ÌJ]M�U9�6x_m̀H�̂ò ÌJ]M�U=�6 ihyehBfz�Bf{ihjDkBif|}~�M�a �6��2�����������2�� ��

�T;QU9W�(*S����2��������&��'�U9��'�����

#�d��/|}~��M�a �6��2�����������2�� ��

�T;QU9W�(*S����2��������&��'�U9��'�����

#�a �DCCeAAihBeA|}~�n�M�a ��1����a�������� 2���� ���2�����|}~�n�M�d��/�1����a�������� 2���� ���2�����DzefC@�EBAkBfzA�Dfy�D>>higDEA�(� �

����6�RU��

52�� �$�6�������

S����V=9UU;���a

������OU�OR����U9OR�.��

�0��
���������0��#

��3�2��.�� ������2�� �3/���

��)���'�#������������������������ ��OU�* �������

�a�������'������*1�9<;RU899:VU8:9O9V

|}~��¡Im]òIK dlookenbill Line

�0!�"�1����#��&����2�������������"������������3����45�6789/:5�8#�����8�����5�����;&��"��< �=�!�������1"��������������������!��!��>�+�/"����6����,�/"����05����?�/"����6�����+�/"����0

�@6/���������'�����A"��������������������"����������!���5��������!4�"���#����������A��!���������������5��������A"�5���������&�"��������� �B�����������!��!������!�� �3��!�����!"���������� �/8=7������%��

�/���!������������&��=6/ �%���,1�����80�8�C������!���!������)))���D �6/�"������"�#���������&!�������������������1��������"�&�'&��!������������������"�<����'�����������&�"���� �796������%��

�6@8E�/����������������!��!������A�"��#�A!�"�1��

����F�,5?,F?�G�?HI?�"�����

�:8J .�C/6D�:8 K))�(K?)�C���������������D

LMNOPQRSTTUVSQR�WXYSZ�[X\]TS_̂S�̀abc�UQRSTTUVSQR�dXYSZ�eX\]TS�Uf�R_S�eXfR�gXfRhSiiSgRUjS�dXYSZ�f]ddTk�ljlUTlmTS�RX\lkn�PR�\STUjSZf�c�ledf�Xi�QXRUoglRUXQ�lddTUlQgS�gUZg]UR�dXYSZ�lQ\�m]UTRhUQ�fkQg_ZXQUplRUXQ�iXZ�lddTUlQgSf�iZXe�qkfRSe�qSQfXZrstSQRSurs�v[qwxys�lQ\�z_SSTXg{rn�̂_S�̀abc|f�l\jlQgS\�eUgZXdZXgSffXZ�\SfUVQ�Uf�kSlZf�l_Sl\�Xi�R_S�gXedSRURUXQn�PRf�fYURg_�eX\S�dXYSZ�f]ddTk�\SfUVQ�Uf�]d�RX�̀}~�eXZS�SiogUSQR�R_lQ�gXedSRURUjS�TUQSlZ�eX\S�dXYSZ�f]ddTUSfn_̂S�̀abc�Uf�l�c�led�QXRUoglRUXQ�dXYSZ�SudlQ\SZ�R_lR�dZXjU\Sf�URf�XYQ�vx�dXYSZ�gXQQSgRUXQs�mlRRSZk�g_lZVUQV�gUZg]URs�lQ\�mlg{]d�mlRRSZk�iXZ�]fS�YUR_�R_S��XQSkYSTT�qUTSQR��QUV_R�fSZUSf�oZS�lTlZe�gXQRZXT�dlQSTf���vxWf�n�̂_S�̀abc�Uf�R_S�gXfRhSiiSgRUjS�fXT]RUXQ�iXZ�dXYSZUQV�QXRUoglRUXQ�lddTUlQgSf�ZS�]UZS\�mk�R_S�veSZUglQf�YUR_��UflmUTURUSf�vgR��v�v�n�̂_S�̀abc�_lf�m]UTRhUQ�v�qP�gl\SQgS�dlRRSZQn�̂_S�X]Rd]R�gUZg]URf�glQ�mS�dZXVZleeS\�lf�QXRUoglRUXQ�lddTUlQgS�gUZg]URfs�XZ�lf�l]uUTUlZk�dXYSZ��gXQoV]ZlmTS�iXZ�gXQfRlQRs�ZSfSRRlmTSs�XZ�\XXZ�_XT\SZ�dXYSZ�n�������������_̂S�̀abc�Uf�gXedlRUmTS�YUR_�R_S�iXTTXYUQV��XQSkYSTT�qUTSQR��QUV_R��vxWf���c��}���c��}w�q��̀��}�����̀��}���w�q��c�}���c�}}��̀�}���̀�}}

��
������������������
�/��
����������/���0'�

����1� �����2 �1 �� �������1���

���1������1���������������1�3������ ��������1��� 41�� #�5 � �&��'�1������� #�����0 �'���� �+1��������� �7889::;9;:::

<:=;�0 >?@ABCDEFGHIJKK�LMNHOPMQOPR�S;T�.�U�SV#V<T�%�U�WT�X�Y:8#;�U�W8#=�U�Z#;���[\]M̂ M̂O_�̀HM_]aR�7#Z 2 bcdBefcgbchDE�F̂ HIJaMO_�iHN ĤIJajIHR�WVk�����SV8k���Y8k*����:=k*[ljNMmManR�S8����=Wo�� �'1�����,�Y���3���� ���[bEbCheBCDEp�qr�sÔjaR�SV8t5*����V#Z5FjâjaR�V:tX*����;5\aJOmun�v�qKJIN�rjIIHOaR�S8�5wQaMxyJaMQOzqj{|�}Q~HI�rMIyjMaPR�:Fjâja�rQOx_jIJaMQOR��rKJPP�q��\anKH�����rKJPP����\anKH�����rKJPP�q�v���rKJPP��qN P̂�}HI�Fjâja�rMIyjMaR�W#8�Y;#8���� ����� [wQaMxyJaMQO�rMIyjMa�FjâjaR�V8#:���VZ#WtX*���W#85� ��'�Om�Q���MOH��HPMPaJOyHR�:#Z)�%���(��

41��

�������1���JaaHIn�r]JI_MO_�rĴJyManR�Z#8���W<#85.fe�beBc��Bc�fegDhBfc����R�/�� ��$��1 DCCbAAfeBbA���R��� �,���U�5��

��,�*�2�� �#�S;��%�U�S8��.�U�;��X�Y:8;����%�U�V<:����.�U�S<V����X[\��\r�R��+ ����D�bcC@�EBAhBc�A�Dc��D>>efdDEA��*+�$�������

������5�ZV���(� �

���*��,����� ¡�:V=9=89��t� �¢/t X����W<8W7Z£��

���£�SS¤SZ��¥�V8SZ�.��

�/��
���������/��#

¦§̈�©§̈ª�«¬§̈©®̄«§¬�HJIO�NQIH�JuQja�\MKHOa��OM_]a°P�}IQmjya�JOmQa]HI�̂IQmjyaP�JGJMKJuKH�un�GMPMaMO_�~~~|PMKHOa±OM_]a|yQN²§¬ª³́ªµµ�¶«µª¬̄�·¬«̧¹̄SV�* �������

���������'������*0�8;:ZV7889WV798S8W&&&#

Fire Alarm Documents (FAD) Cabinet Fire Alarm Storage Cabinet Description The Notifier Fire Alarm Documents Cabinet (FAD) is the perfect solution to meet the demanding code standards required today. Noti-fier's primary goal is to manufacture code compliant solutions and this product allows you to do just that. This cabinet is the answer to comply with the NFPA 72 2007, Section 6.2.2.1 requirements which states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit.

The Fire Alarm Documents cabinet may be used as a storage box for both printed and digital documentation, enabling you to store the system’s test and certified inspection documents, service records, manuals and AS built drawings.

This cabinet is constructed of durable 16 gauge steel with a solid piano hinge and key lock. The cabinet includes a 4GB USB memory flash drive interface. Using a standard USB B connector, the USB flash drive interface allows you to use any standard USB printer cable to upload or download information. This feature allows you to store the fire alarm software in one secure place, so that the Techni-cian can easily access the software and service the system.

The Fire Document Box (FDB) interior is designed to contain critical manuals and documents. It is constructed with a durable steel retainer. The FDB has two key ring hooks to hold system keys, and a frame to insert Authorized personnel business cards. In the inner door, you can add the Legend Sheet to record property, system, ser-vice, code and AHJ certification information, as well as required doc-umentation. (See Figure 2).

Features

• Installed with a 4 gigabyte digital flash drive interface with USB B connector.

• Overall Dimensions:

12” W x 13” H x 2¼” D (30.48 W x 33.02 H x 5.71 D cm).

• Offers two, key ring hooks to hold the system keys.

• Contains a frame plate to insert Authorized Personnel business cards.

• Constructed with 16 gauge steel box and cover for added security with a solid stainless steel hinge.

• Coated with a durable, baked-on finish (other colors available).

• Built with a stainless steel piano hinge with standard ¾”cat 30 key lock (other lock assemblies available).

• Includes a Legend Sheet to record passwords and system infor-mation.

• Imprinted with white indelible ink, 1" high lettering labeled, "FIRE ALARM DOCUMENTS.”

Specifications FAD Fire Alarm Documents Cabinet Dimensions: 12”W x 13”H x 2 1/4” D, (30.48 W x 33.02 H x 5.71 D cm).

Door Keylock: Barrel lock and piano hinge. 3/4” barrel lock and 12” (30.48 cm) piano hinge.

FAD Cabinet: UL® Listed, constructed of 18 gauge cold rolled steel.

Cabinet Finish: Red powder coat epoxy finish

Cabinet Cover Label: Silkscreen imprinted with white indelible ink, 1" high lettering labeled, "FIRE ALARM DOCUMENTS"

Cabinet Keylock: Keylocked with 3/4" barrel lock and 12" (30.48

cm) width stainless steel piano hinge.

Cabinet Backbox: The backbox includes a 4-hole knockout mount-ing pattern.

Cabinet Frame Plate: Insert frame plate accommodates and pro-tects standard 8 1/2 x 11 manuals and document records.

Cabinet Inner Door Label: Legend Sheet attached to the inner door frame for system required documentation, key contacts and code information.

Cabinet Flash Drive Interface: 4 Gigabyte (minimum) digital flash memory drive with a standard USB B connector (used to upload and download information) is securely assembled to the interior cabinet.

The drive is restricted to Authorized personnel with permission to use secure hardware devices to access the records.

Cabinet Key Holder: Two key ring holders and a pre-assembled frame plate to insert Authorized Personnel business cards.

Standards The Fire Alarm Documents (FAD) Cabinet is designed to comply with the following standard:

UL Standard: S2580

Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process.

Consult factory for latest listing status.

UL: S2580, Vol. 3

CSFM: 7300-0553-0110

NFPA: 72 2007

NEMA

ISO 9001 Certification

Ordering Information NF-FAD: Fire Alarm Storage Cabinet, Red. Includes NOTIFIER lock.

DN-61031:A • 05/31/18 — Page 1 of 3

Figure 1 shows the interior enclosure of the Fire Alarm Documents cabinet.

Figure 2 shows the Legend Sheet attached to the inner door of the Fire Alarm Document Cabinet.

Figure 2 Legend Sheet

Property Information Minimum Required Documentation

Name of Property:_______________________________ 1 Written narrative providing intent and system description.

Address:_______________________________________ N/A Enclosed or Alt. Location:_____________________________________ Description of Property: ___________________________ 2 Riser diagram Occupancy Type:________________________________ N/A Enclosed or Alt. Location:_____________________________________ Certification and Approvals 3 Floor plan layout showing location of all devices and control equipment.

16.1 System Installation Contractor: N/A Enclosed or Alt. Location:_____________________________________

This system, as specified herein, has been installed and tested according to all NFPA Standards cited therein.

4 Sequence of operation in either an input/ output matrix or narrative form.

N/A Enclosed or Alt. Location:_____________________________________

Signed:________________________________________ 5 Equipment technical data sheets.

Printed Name:__________________________________ N/A Enclosed or Alt. Location:_____________________________________ Date: ______/______/______ 6 Manufacturers published instructions, including operation and maintenance instruction.

Organization:___________________________________ N/A Enclosed or Alt. Location:_____________________________________ Title:__________________________________________ 7 Battery calculations (where batteries are provided).

Phone:________________________________________ N/A Enclosed or Alt. Location:_____________________________________

16.5 Authority Having Jurisdiction: 8 Voltage drop calculations for notification appliance circuits.

I have witnessed a satisfactory acceptance test of this with N/A Enclosed or Alt. Location:_____________________________________ system and find it to be installed and operating properly in 9 Completed record of inspection and testing in accordance with 7.6.6 and 7.8.2.

accordance with its approved plans and specifications, N/A Enclosed or Alt. Location:_____________________________________ its approved sequence of operations, and with all NFPA 10 Completed record of completion in accordance with 7.5.6 and 7.8.2.

standards cited herein. N/A Enclosed or Alt. Location:_____________________________________ Signed:________________________________________ 11 Copy of site specific software, where applicable.

Printed Name:__________________________________ N/A Enclosed or Alt. Location:_____________________________________ Date: ______/______/______ 12 Record (as-built) drawings.

Organization:___________________________________ N/A Enclosed or Alt. Location:_____________________________________ Title:__________________________________________ 13 Periodic inspection, testing, and maintenance documentation in accordance with Phone:________________________________________ Section 7.6.

Equipment Information:___________________________ N/A Enclosed or Alt. Location:_____________________________________ ID No. 1:_______________________________________ 14 Records, record retention, and record maintenance in accordance with 7.7.

Serial: ________________________________________ N/A Enclosed or Alt. Location:_____________________________________ Access Code: __________________________________ ID No. 2:_______________________________________ Serial: ________________________________________ Access Code: __________________________________ Signed:___________________________________Date:______/______/______

USB Storage Interface requires

Standard USB-B Connector

Key Ring Hooks

Business Card Holder

Legend sheet used to store system information including the following:

- Contacts

- Sign-off

- Maintenance

- Test information

- Alternate locations of additional records

Figure 1 Fire Alarm Documents Cabinet Page 2 of 3 — DN-61031:A • 05/31/18

Notifier ® is a registered trademark of Honeywell International Inc. Space Age Electronics, Inc. is a ©copyright. UL® is a registered trademark of Underwriter’s Laboratories Inc.

This document is not intended to be used for installation purposes.

We try to keep our product information up-to-date and accurate.

We cannot cover all specific applications or anticipate all requirements.

All specifications are subject to change without notice.

Country of Origin: US

NOTIFIER

12 Clintonville Road

Northford, CT 06472 www.notifier.com

PS

SE

RI

ES

TERMINALS: (mm)

DIMENSIONS: inch (mm) PERFORMANCE SPECIFICATIONS Nominal Voltage 12 volts (6 cells)

Nominal Capacity 20-hr. (600mA to 10.50 volts) 10-hr. (1.15A to 10.50 volts) 5-hr. (2.00A to 10.20 volts) 1-hr. (9.00A to 9.00 volts)

12.00 AH

11.50 AH

10.00 AH

9.00 AH

Approximate Weight 8.14 lbs. (3.69 kg)

Internal Resistance (approx.) 20.0 milliohms

Max Short-Duration Discharge Current (10 Sec.) 50.0 amperes

Shelf Life (% of nominal capacity at 68°F (20°C) 1 Month 3 Month 6 Month

97% 91% 83%

Operating Temperature Range Charge Discharge

5°F (-15°C) to 122°F (50°C) -4°F (-20°C) to 140°F (60°C)

Case ABS Plastic

Power Sonic Chargers PSC-122000A-C

PSC-122000-PC

www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website.

© 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.

All data subject to change without notice. E&O.E

CORPORATE HEADQUARTERS

(USA AND INTERNATIONAL EXCLUDING EMEA)

Power-Sonic Corporation 7550 Panasonic Way, San Diego, California 92154 T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com

POWER-SONIC EUROPE LIMITED

(EMEA – EUROPE, MIDDLE EAST AND AFRICA)

3 Buckingham Square, Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com

General Purpose

Fire & Security

Emergency Lighting

MH20845

Sealed Rechargeable

MODEL PS-12100 F1

12 Volt 12.0 Amp. Hr.

Battery www.power-sonic.com BAT

TE

RY

MUST BE RE C

YC

LE

D

Pb

NONSPILLABLE

L

HT

W

H

Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice.

L: 5.95 (151) W: 4.00 (102) H: 3.70 (94) HT: 3.86 (98)

L: 5.95 (151) W: 4.00 (102) H: 3.70 (94)

HT: 3.86 (98)

Tolerances are +/- 0.04 in.

(+/- 1mm) and +/- 0.08 in.

(+/- 2mm) for height dimensions. All data subject to change without notice.

FEATURES

• Absorbent Glass Mat (AGM) technology for superior performance

• Valve regulated, maintenance free spill proof construction

• Power/volume ratio yielding excellent energy density

• Rugged vibration and impact resistant ABS case and cover

• Gas recombination technology

• 5 year design life

APPROVALS

• Approved for transport by air. D.O.T., I.A.T.A., F.A.A.

and C.A.B. certifi ed

• U.L. recognized

• ISO9001:2015 – Quality management systems

Medical

Re v1

: 1 1/

PS-12100 12V 12.0 AH @ 20-hr.

12V 11.5 AH @ 10-hr.

Rechargeable Sealed Lead Acid Battery PS – General Purpose Series

OR

Torque – Not Applicable

4.75

1.5

6.35 3.2

2.5

0.8

F1: Quick disconnect tabs, 0.187" x 0.032" – Mate with AMP. INC. FASTON “187” series

Torque – Not Applicable

6.35

1.5

7.95 3.4

2.5 0.8

F2: Quick disconnect tabs, 0.250" x 0.032" – Mate with AMP. INC FASTON “250” series http://www.power-sonic.com

PS

SE

RI

ES

www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website.

© 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.

All data subject to change without notice. E&O.E

CORPORATE HEADQUARTERS

(USA AND INTERNATIONAL EXCLUDING EMEA)

Power-Sonic Corporation 7550 Panasonic Way, San Diego, California 92154 T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com

POWER-SONIC EUROPE LIMITED

(EMEA – EUROPE, MIDDLE EAST AND AFRICA)

3 Buckingham Square, Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com

SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE

Ca pa ci ty

R et en tio n Ra tio

Standing Period (Months)

0 2 4 6 8 10 12 14 16 18 20

40oC (104oF)

30oC (86oF)

20oC (68oF)

5oC (41oF)

Charging is not necessary unless 100% of capacity is required.

Charging before use is necessary to help recover full capacity.

0 1 2 3 4 5

Ambient Temperature 20˚C (68˚F)

Float Charging Voltage

2.25 - 2.30 V/Cell

Re te nt io n Ca pa ci ty

Years

SHELF LIFE & STORAGE

LIFE CHARACTERISTICS IN STAND-BY USE

Ca pa ci ty

R et en tio n Ra tio

Standing Period (Months)

0 2 4 6 8 10 12 14 16 18 20

40oC (104oF)

30oC (86oF)

20oC (68oF)

5oC (41oF)

Charging is not necessary unless 100% of capacity is required.

Charging before use is necessary to help recover full capacity.

0 1 2 3 4 5

Ambient Temperature 20˚C (68˚F)

Float Charging Voltage

2.25 - 2.30 V/Cell

Re te nt io n Ca pa ci ty

Years

SHELF LIFE & STORAGE

LIFE CHARACTERISTICS IN STAND-BY USE

CHARGING

Cycle Applications: Apply constant voltage charge at 2.35v/c – 2.45v/c (14.1 – 14.7v for 12v Monobloc) at 20°C.

Initial charging current should be set at less than 0.25C Amps. Switch to fl oat charge to avoid overcharging.

“Float” or “Stand-By” Service: Apply constant voltage charge of 2.25v/c – 2.30v/c (13.5 to 13.8 volts for 12v Monobloc at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition.

Temperature Compensation: Charging Voltage for both Cyclic and Standby applications should be regulated in relation to ambient temperature. As temperature rises charging voltage should be reduced to prevent overcharge and increased as temperature falls to avoid undercharge.

For further charging information including temperature compensation factors, see Power Sonic Technical Manual/ Power Sonic Charger specifi cations.

CHARGERS

Power Sonic offers a wide range of chargers suitable for batteries with a variety of capacities.

Please refer to our website for more information on our switch mode and transformer type chargers.

Please contact our technical department for advice if you have diffi culty in locating a suitable charger.

FURTHER INFORMATION

Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certifi cation, etc.

APPLICATIONS

• General purpose

• Emergency lighting

• Medical

• Fire and security

PS-12100 12V 12.0 AH @ 20-hr.

12V 11.5 AH @ 10-hr.

Rechargeable Sealed Lead Acid Battery PS – General Purpose Series

Re v1

: 1 1/ http://www.power-sonic.com

F E AT U R E S & B E NE F I T S

• Installer can open station without causing an alarm condition

• Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition

• Key operated test and reset lock using lock plate actuator

• Key matches compatible FACP locks

• Meets ADA requirement for 5 lbs maximum pull force to active

• Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13])

• Shell, door, and handle molded from durable

LEXAN®

• Reliable analog communications for trouble-free operation

• Braille text on station handle

• Rotary address switches for fast installation

• Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled

• UL Listed, including UL 38, Standard of Manually Actuated Signaling System

• CSFM Listed

• MEA Listed

SK-PULL-SA / SK-PULL-DA

Intelligent Pull Stations

The SK-PULL-SA is a single action pull station requiring only one motion to activate the station. The SK-PULL-DA is a dual action pull station requiring two motions to active the station. The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel (FACP).

Extremely easy to operate, the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal. The FACP recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm.

INSTALLATION

The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13”(5.40 cm) or double gang or 4” (10.61 cm) square electrical box. You can also use the optional (System Sensor® PN BG-TR) trim ring if the station is being semi-flush mounted.

SK-PULL-SA

SK-PULL-DA

dlookenbill Line dlookenbill Line

For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com.

Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of

Microsoft Corporation.

Silent Knight®, System

Sensor® and Honeywell® are registered trademarks of Honeywell

International, Inc.

This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice.

For Technical Support, call 800-446-6444.

SK-PULL-SA / SK-PULL-DA Technical Specifications

PHYSICAL

Dimensions: 5.5” H x 4" W x 1.45" D (14 x 10.2 x

3.7cm)

Housing Material: LEXAN polycarbonate resin

Bi-Colored LED:

Blinking Green: Normal

Steady Red: Alarm

Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station

ELECTRICAL

Operating Voltage: 15 – 32VDC

SLC Standby and Alarm Current: 350�A

Wire Gauge: Up to 12AWG (3.1 mm2)

ENVIRONMENTAL

Operating Temperature: 32ºF – 120ºF (0ºC –

49ºC)

Humidity: 10% – 93% non-condensing

ORDERING INFORMATION

SK-Pull-SA: Single Action Pull Station

SK-Pull-DA: Dual Action Pull Station

ACCESSORIES

BG-TR: Optional trim ring.

SB-I/O: Surface backbox, indoor/outdoor.

* Unless otherwise noted, specifications apply to

SK-Pull-SA and SK-Pull-DA

COMPATIBILITY

The SK-PULL-SA AND SK-PULL-DA are compatible with the following Honeywell Silent Knight fire alarm control panels:

6820: Addressable fire alarm control panel

6820EVS: Addressable fire alarm control panel with an emergency voice system.

6808: Addressable fire alarm control panel

6700: Addressable fire alarm control panel

5700: Addressable fire alarm control panel

5808: Addressable fire alarm control panel

5820XL: Addressable fire alarm control panel

5820XL-EVS: Addressable fire alarm control panel with an emergency voice system

Doc 350135 | Rev E | 11/17

© 2017 Honeywell International Inc.

For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com

Honeywell Silent Knight 12 Clintonville Road

Northford, CT 06472

800-328-0103 dlookenbill Line

Addressable Devices

SK-FIRE-CO-W

Multi-Criteria Fire/CO Detector

SK-FIRE-CO-W in B200S-WH sounder base

General Description

SK-FIRE-CO-W is a plug-in, addressable device that provides both fire and carbon monoxide (CO) detection. The detector combines four separate sensing elements to sense multiple components of a fire: smoke, CO, light/flame, and heat. This approach enables enhanced sensitivity to real fire with heightened immunity to nuisance particulates. For CO, the detector’s electrochemical sensing cell creates a separate signal for life safety CO detection.

Multiple sensors and communication can greatly reduce nuisance alarms compared to single sensing methods. Sophisticated algorithms maximize the advantages of all four sensor types creating our best detection strategy offering heightened immunity to nuisance particulate and enhanced sensitivity to real fire.

• Photoelectric sensors detect airborne particles associated with smoke.

• Thermal sensors detect heat and rate-of-rise (135°F fixed temperature threshold).

• Infrared sensors discern light patterns in the environment as an additional data point for alarm determination.

This ability to reject certain nuisance alarm triggers, such as theater smoke, supports the use of the fire/CO detector in applications where moderate to heavy nuisance conditions exist that might cause single sensing detectors to false alarm.

UL models meet UL 268 7th edition and UL 521 listing requirements for fire detection and UL 2075 standard for system-connected life safety carbon monoxide detection.

Released through the incomplete burning of various fuels, CO is a colorless, odorless and deadly gas that is virtually impossible to detect with the human senses. Because the potential exists for dangerous levels of CO to accumulate in almost any building, legislation mandating the use of CO detection in commercial spaces continues to grow.

B200S series intelligent sounder bases are recommended for use with SK-FIRE-CO-W. These bases can generate either a Temp 3 pattern for fire or a Temp 4 pattern for CO alarm indication. The B200S series bases recognize the System Sensor synchronization protocol for use as a component of the general evacuation signal — along with other System Sensor Audible/Visible devices — when connected to a power supply or

Fire Alarm Control Panel (FACP) output capable of generating the System Sensor synchronization pulses.

FEATURES & BENEFITS

• Detects all four major elements of a fire

• Separate CO detection signal

• Separate audible signal for fire or CO alarm when used with a B200S series base

• Highest nuisance alarm immunity

• Automatic drift compensation for smoke and CO sensors

• RealTest® CO testing capability

• New modern profile with expanded color options

• Uses only one address on the SLC loop

• UL 268 7th edition, UL 521, and UL 2075 listed

• 10-year CO cell with end-of-life warning dlookenbill Text Box Note: Thermal rate-of-rise detection and infrared detection capabilities shall be disabled for this design. For our application, we intend to only use the smoke detection and CO detection capabilities of this detector.

dlookenbill Line dlookenbill Line

SK-FIRE-CO-W Technical Specifications

SK-62001 | A | 05/19

©2019 Honeywell International Inc.

Silent Knight® and RealTest® are registered trademarks of

Honeywell International Inc.

©2019. All rights reserved.

Unauthorized use of this document is strictly prohibited.

This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements.

All specifications are subject to change without notice.

Country of origin: Mexico

Honeywell Silent Knight 12 Clintonville Road

Northford, CT 06472-1610

203.484.7161 www.silentknight.com

PHYSICAL/OPERATING

Dimensions:

Height: 2.7" (69 mm) installed in B200S series sounder base

Diameter: 6.875" (175 mm) installed in B200S series sounder base

Weight: 3.4 oz. (95 g)

Operating Humidity Range: 15% to 90% Relative

Humidity, Non-condensing

Operating Temperature Range: 32°F to 100°F (0°C to

38°C)

Air Velocity: 0 to 4000 ft./min. (0 to 1219.2 m/min.)

ELECTRICAL SPECIFICATIONS

Operating Voltage Range: 15 to 32 VDC

Operating Current @ 24 VDC: 200 uA (one communication every 5 seconds with green LED blink on communication)

Maximum Alarm Current: 2 mA @ 24 VDC (one communication every 5 seconds with red LED solid on)

Maximum Current: 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED solid on)

Isolator Load Rating: 0.0063

CO MONITORING UL STANDARD REFERENCE

Alarm thresholds (in parts per million) are as follows for:

70 ± 5ppm: Detector response time 60 – 240 min.

150 ± 5ppm: Detector response time 10 – 50 min.

400 ± 10ppm: Detector response time 4 – 15 min.

STANDARDS

Per UL standard 2075, the SK-FIRE-CO-W has have been tested to the sensitivity limits defined in UL Standard

2034.

UL Standard: UL 268 7th Edition

AGENCY LISTINGS AND APPROVALS

The listings and approvals below apply to the SK-FIRE-

CO-W. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process.

Consult the factory for the latest listing status.

UL: S6173

CSFM: 7272-0559:0517

ORDERING INFORMATION

SK-FIRE-CO-W: Advanced multi-criteria fire/CO detector, white

Bases

B501-WHITE: 4" Mounting base, white

B501-WHITE-BP: 4" mounting base, white, 10-pack

B501-IV: 4" Mounting base, ivory

B501-BL: 4" Mounting base, black

B300-6: 6" Flanged mounting base, white

B300-6-BP: 6" Flanged mounting base, white, 10-pack

B300-6-IV: 6" Flanged mounting base, ivory

B200S-WH: Intelligent addressable sounder base, white

B200S-IV: Intelligent addressable sounder base, ivory

B200S-LF-WH: Intelligent addressable sounder base, low-frequency, white

B200S-LF-IV: Intelligent addressable sounder base, low-frequency, ivory

B224BI-WH: Isolator base, white

B224BI-IV: Isolator base, ivory

B224RB-WH: Relay base, white

B224RB-IV: Relay base, ivory

Accessories

SMB600: Surface mounting kit (flanged)

TR300: Trim ring, white

TR300-IV: Trim ring, ivory

CK300-IR: IR color kit (includes cover and trim ring), white, 10 pack

CK300-IR-IV: IR color kit (includes cover and trim ring), ivory, 10 pack

CK300-IR-BL: IR color kit (includes cover and trim ring), black, 10 pack

RA100Z: Remote LED annunciator

M02-04-00: Detector test magnet

M02-09-00: Telescoping test magnet

• New modern profile for improved aesthetics

• Stable communication technique with noise immunity

• Low standby current

• Two-wire SLC connection

• Optional remote, single- gang LED accessory

• Dual LED design provides 360° viewing angle

• Remote test feature from the panel

• Built-in functional test switch activated by external magnet

• Built-in tamper-resistant feature

• Sealed against back pressure

• Expanded color options

• SEMS screws for wiring of the separate base

• Optional relay, isolator, and sounder bases

• Plugs into separate base for ease of installation and maintenance

SK-PHOTO-W Series Intelligent Plug-In Photoelectric Smoke

Detector

Honeywell Silent Knight SK-PHOTO-W Series plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards.

The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level.

Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DNR Series duct detector housings.

SK-PHOTO-W

DETECTOR SPACING AND

APPLICATIONS

Honeywell recommends spacing detectors in compliance with NFPA 72.

In low airflow applications with smooth ceiling, space detectors 30 feet (9m).

For specific information regarding detector spacing, placement, and special applications refer to NFPA 72.

System Smoke Detector Application

Guide, document A05-1003, is available at systemsensor.com

INSTALLATION

The SK-PHOTO-W Series plug-in detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector.

Mount base (all base types) on an electrical backbox which is at least 1.5"

(3.81 cm) deep.

NOTE:

• Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring

“T-taps” or branches are permitted for

Style 4 (Class “B”) wiring.

• When using relay or sounder bases, consult the installation sheet for device limitations between isolator modules and isolator bases.

ORDERING INFORMATION

SK-PHOTO-W: Photoelectric smoke detector, white.

SK-PHOTO-R-W: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, white.

SK-PHOTO-T-W: Photoelectric smoke detector with thermal sensing, white.

INTELLIGENT BASES

B300-6: White, standard flanged low-profile mounting base.

B300-6-BP: Bulk pack of B300-6, package contains 10.

B300-6-IV: Ivory, standard flanged low-profile mounting base.

B501-WHITE: White, standard

European flangeless mounting base. UL listed.

B501-BL: Black, standard European flangeless mounting base. UL listed.

B501-IV: Ivory, standard European flangeless mounting base. UL listed.

B200S-WH: White, Intelligent, programmable sounder base.

B200S-IV: Ivory, Intelligent, programmable sounder base.

B200SR-WH: White, Intelligent sounder base for retrofit applications.

B200SR-IV: Ivory, Intelligent sounder base for retrofit applications.

B200S-LF-WH: White, Low Frequency

Intelligent, programmable sounder base.

B200S-LF-IV: Ivory, Low Frequency

Intelligent, programmable sounder base.

B200SR-LF-WH: White, Low

Frequency Intelligent sounder base for retrofit applications.

B200SR-LF-IV: Ivory, Low Frequency

Intelligent sounder base for retrofit applications.

B224RB-WH: White, plug-in System

Sensor relay base.

B224RB-IV: Ivory, plug-in System

Sensor relay base.

B224BI-WH: White, plug-in System

Sensor isolator detector base.

B224BI-IV: Ivory, plug-in System

Sensor isolator detector base.

ACCESSORIES

CK300: Color Kit (includes cover and trim ring), white, 10-Pack.

CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-Pack.

CK300-BL: Color Kit (includes cover and trim ring), black, 10-Pack.

M02-04-01: Detector test magnet.

M02-09-00: Telescoping test magnet.

RA100Z: Remote LED annunciator

SMB600: Surface Mounting Kit

(flanged).

TR300: Replacement trim ring for

B300-6, white.

TR300-IV: Replacement trimring for

B300-6-IV, ivory.

For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com

Honeywell Silent Knight 12 Clintonville Road

Northford, CT 06472

800-328-0103

For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com.

Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of

Microsoft Corporation.

Silent Knight®, System

Sensor® and Honeywell® are registered trademarks of Honeywell

International, Inc.

This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice.

For Technical Support, call 800-446-6444.

SK-PHOTO-W Series Detector Technical Specifications

PHYSICAL

Height: 2.0" (51mm) installed in B300-6 base

Diameter: 6.2" (156mm) installed in B300-6 base 4.1" (104 mm) installed in B501 base

Weight: 3.4 oz (95 g)

ENVIRONMENTAL

Operating Temperature range:

Photo: 32°F to 122°F (0°C to 50°C)

Photo with Thermal: 32°F to 100°F (0°C to

38°C)

UL listed Velocity range: Photo/Photo with

Thermal: 0 to 4,000 fpm (0 to 20 m/sec)

(suitable for installation in ducts)

Humidity: 10% to 93% non-condensing

Thermal Ratings: Fixed Temperature Set point:

135°F (57°C)

ELECTRICAL RATINGS

Voltage Range: 15 to 32VDC peak

Operating Current @ 24VDC: 200�A (one communication every 5 seconds with green LED blink on communication)

Maximum Current: 4.5mA @ 24VDC (one communication every 5 seconds with amber LED solid on).

Doc 351634 | Rev A | 04/18

© 2018 Honeywell International Inc.

COMPATIBILITY

The SK-PHOTO-W series detectors are compatible with the following Honeywell Silent

Knight fire alarm control panels:

6820: Addressable fire alarm control panel

6820EVS: Addressable fire alarm control panel with an emergency voice system.

6808: Addressable fire alarm control panel

6700: Addressable fire alarm control panel

5700: Addressable fire alarm control panel

5808: Addressable fire alarm control panel

5820XL: Addressable fire alarm control panel

5820XL-EVS: Addressable fire alarm control panel with an emergency voice system

AGENCY LISTINGS AND APPROVALS

For exact certification listings for each model, please reference the respective agency Web site.

UL listed: S6173

FM approved

CSFM: 7272-0559:0523

• Single contact monitor

• Support for Class A and Class B wiring

• Fully supervised

• Panel controlled status LED that flashes green in normal state and is solid red in alarm

• SEMS screws for easy wiring

• UL Listed

• Rotary address switches for fast installation

SK-MONITOR

Intelligent Monitor Module

The SK-MONITOR is an addressable monitor module for use with

Honeywell Silent Knight Series fire alarm control panels (FACPs). The

SK-MONITOR is intended for use in intelligent, two-wire systems, where individual address of each module is selected using the built-in rotary switches.

The SK-MONITOR supports Class A supervised or Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions.

INSTALLATION

The SK-MONITOR mounts directly into a 4” square electrical box. The box must have a minimum depth of 2-1/8”. A surface mount electrical box

(System Sensor® PN SMB500) is available from Silent Knight.

SK-MONITOR

For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com.

Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of

Microsoft Corporation.

Silent Knight®, System

Sensor® and Honeywell® are registered trademarks of Honeywell

International, Inc.

This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice.

For Technical Support, call 800-446-6444.

SK-MONITOR Technical Specifications

PHYSICAL

Height: 4.5”H x 4” W x 1.25”D (11.4 X 10.2 X 3cm)

Shipping Weight: 6.3 oz (196 g)

ELECTRICAL

Operating Voltage: 15 – 32VDC

Current Draw (LED on): 5.0mA max

Operating Current (LED flashing): 375�A

Standby Current: 400 �A max @ 24 VDC (one communication every 5 sec with 47K EOL); 550 �A max @ 24 VDC (one communication every 5 sec with EOL <1K)

5.5 mA (with LED latched on)

LED Current: 5.5 mA (with LED latched on)

End-of-Line Resistance: 47K � Initiating Device Circuit Wiring Resistance: 1,500

� max

SLC Loop Resistance: 40 � max.

ENVIRONMENTAL

Operating Temperature: 32ºF – 120ºF (0ºC –

49ºC)

Humidity: 10% – 93% non-condensing

ORDERING INFORMATION

SK-MONITOR: Monitor Module

ACCESSORIES.

SMB500: 4” Square surface mount electrical box

COMPATIBILITY

The SK-MONITOR is compatible with the following Honeywell Silent Knight fire alarm control panels:

6820: Addressable fire alarm control panel

6820EVS: Addressable fire alarm control panel with an emergency mass notification system.

6808: Addressable fire alarm control panel

6700: Addressable fire alarm control panel

5700: Addressable fire alarm control panel

5808: Addressable fire alarm control panel

5820XL: Addressable fire alarm control panel

5820XL-EVS: Addressable fire alarm control panel with an emergency mass notification system

Doc 350131 | Rev G | 11/17

© 2017 Honeywell International Inc.

For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com

Honeywell Silent Knight 12 Clintonville Road

Northford, CT 06472

800-328-0103

7300-1653:0525 7135-1653:0503 7135-1653:0526

Horn Strobes and Strobes:

S5512, S4011

3057072

FM23FPUS0195

Horns:

S4011

Agency Listings

AVDS916-01 • 10/03/2023 • Page 1

Features

• LED technology provides lower current draw

• �Digital Voltage Meter (DVM) diagnostic test points for Horn Strobes and Strobes

• Common aesthetics across the L-Series platform

• Standard and compact sizes

• Tamper-resistant construction

• �Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185

• �Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177

• Rotary switches for candela, tone and volume selections

• �Mounting plate provides plug-in design for easier installation and shorting springs to check wiring continuity

• �Electrically compatible with legacy SpectrAlert, SpectrAlert Advance and L-series devices

• �Synchronization through use of UL approved power supplies that support System Sensor Sync protocol or System Sensor MDL3 Sync Module

• Horns, Strobes and Horn Strobes listed for wall or ceiling use

The System Sensor L-Series and L-Series with LED platform offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draw and modern aesthetics. LED lighting technology offers significantly lower current draw compared to older Xenon bulbs across a full candela range. This improves design flexibility for notification appliance circuits (NACs) while also reducing power supply requirements allowing for simpler and lower cost installations.

Flexible design options meet virtually any application requirement:

wall or ceiling mount, standard or compact sizes, red or white color choices, bezel kits for alternate markings and languages, and LED color lenses for distinctive visual signaling. In addition, installers can easily adapt devices using field selectable candela, tone and volume settings using rotary switches.

The L-Series and L-Series with LED line is developed to simplify installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. The universal mounting plate includes an onboard shorting spring, so installers can test wiring continuity before the device is installed.

In addition, the System Sensor L-Series with LED notification appliances offer a new diagnostic test point feature that allows you to measure device voltage with a digital voltage meter (DVM) without removing the appliance from the wall or ceiling. The DVM test points are discreetly located on the face of the notification appliance which enable faster troubleshooting and end of line (EOL) voltage checks while greatly reducing the risk of misplacing or damaging appliances during troubleshooting.

L-Series and L-Series with LED Indoor Selectable Horns, Strobes and Horn Strobes

System Sensor L-Series and L-Series with LED audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics.

Horns:

S4011

AVDS916-01 • 10/03/2023 • Page 2

L-Series and L-Series with LED Specifications Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage, LED Strobes and Horn Strobes Regulated 24 VDC Nominal Voltage, Horns Regulated 12 VDC or regulated 24 DC/FWR Operating Voltage Range, LED Strobes and Horn Strobes 16 to 33 V (24 V nominal) Operating Voltage Range, Horns 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG

UL/ULC Maxmimum Strobe Current Draw (mA)

Candela Rating

16–33 Volts Wall Ceiling

Candela Range

15 18 18 30 22 22 75 70 70 95 75 75 110 85 — 115 — 90 135 105 — 150 — 110 177 — 115 185 120 —

UL/ULC Current Draw Data, Horn Tones, and Sound Output Data

UL/ULC Maximum Horn Strobe Current Draw (mA) and Sound Output (dBA)

Switch Pos. Sound Pattern

Volume Setting

Current Draw (mA RMS), Horn Strobe, Candela Range (15-185 cd)

Sound Output (dBA)

16-33 Volts 16-33V 15cd 30cd 75cd 95cd 110cd

WALL

115cd

CEILING

135cd

WALL

150cd

CEILING

177cd

CEILING

185cd

WALL

DC

1 Temporal 3 High 35 38 87 92 94 120 189 189 190 190 87 2 Temporal 3 Low 35 38 87 92 94 120 135 135 145 145 79 3 Non-Temporal High 50 52 87 92 94 120 127 127 135 135 87 4 Non-Temporal Low 35 38 87 92 94 120 125 125 130 130 79 5 3.1KHz Temporal 3 High 35 38 87 89 91 115 155 155 165 165 86 6 3.1KHz Temporal 3 Low 35 38 87 89 91 115 128 130 135 135 80 7 3.1KHz Non-Temporal High 40 42 87 89 91 115 125 125 135 135 86 8 3.1KHz Non-Temporal Low 35 38 87 89 91 115 120 120 130 130 80

UL/ULC Maxmimum Horn Current Draw (mA RMS)

Sound Pattern dB 8–17.5 Volts 16–33 Volts

DC DC FWR

Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54

3.1 KHz Temporal High 39 41 54

3.1 KHz Temporal Low 29 32 54

3.1 KHz Non-Temporal High 42 43 54

3.1 KHz Non-Temporal Low 28 29 54

Coded High 43 47 54

3.1 KHz Coded High 42 43 54

AVDS916-01 • 10/03/2023 • Page 3

L-Series with LED Dimensions: Wall-Mounted Equipment

Compact Strobe, Horn Strobe for Wall

Compact Horn

Strobes, Horn Strobes for Walls

Surface Mount Back Box for Walls ( SBBRL/SBBWL)

4.82" (12.24 cm) 1.85"

(4.69 cm)

5.78" (14.68 cm)

1.55" (3.9 cm)

3.57" (9.1 cm)

5.38" (13.7 cm)

Compact Surface Mount Back Box for Walls (SBBGRL, SBBGWL)

4.7" 119 mm

5.67" 144 mm

1.25" 32 mm

3.46" 88 mm 1.25"

32 mm

5.27"

133.9 mm

4.7" 119 mm

5.67" 144 mm

1.25" (31.8 mm)

2.07" (53 mm)

3.46" 88 mm

5.27"

133.9 mm

1.25" (31.8 mm)

2.07" (53 mm)

Horn A0549-00A0613-00 A0554-01

A0617-00 A0557-00A0547-00

Strobes and Horn Strobes for Ceilings

Surface Mount Back Box for Ceilings (SBBCRL, SBCWL)

6.83" diam.

(173.5 mm)

1.25" (31.8 mm)

2.07" (52.6 mm)

6.92" diam.

(175.77 mm)

2.5" (64 mm)

A0608-00 A0546-00

L-Series with LED Dimensions: Ceiling-Mounted Equipment

System Sensor® is a registered trademark of Honeywell International, Inc.

3825 Ohio Avenue • St. Charles, IL 60174 USA Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com

3333 Unity Drive, Mississauga, ON L5L 3S6 Canada Phone: 800-SENSOR2 • Fax: 905-812-0771 www.systemsensor.ca

©2023 System Sensor.

Product…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .