This Task Group Instruction (TGI) details work requirements for replacing the nonskid system on the USS SHOUP (DDG-86) during its FY25 5J1 Selected Industrial Availability (SIA) in Yokosuka, Japan. The work involves replacing approximately 3,055 square feet of nonskid system on the 01 Level deck plating between frames 202 and 329, port and starboard sides, including vertical surfaces up to 4 inches from the deck. The work must conform to MIL-PRF-24667, Type V, Composition G specifications.

The TGI specifies that power tool cleaning to bare metal is required for vertical surfaces following SSPC-SP 11 standards. SRF-JRMC will provide support services including crane operations, electrical utilities, water and steam supply, safety inspections, gas-free inspections, and QA inspections. The work is being contracted on a Firm-Fixed-Price basis, with pricing to be submitted in Japanese Yen (conversion rate of 145.7323 JPY per USD specified for FY25 budget purposes). The contractor must provide detailed pricing using the Price Proposal Breakdown Sheet specified in Section J ATTACHMENT II of solicitation N6264925RA020.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOUO

WebAIM Short Form TASK GROUP INSTRUCTION

08-JAN-2025 1327

20.14.15.2.9020 (September 2024) ICN: 38KC113601 KeyOp: A01

COMPONENT NAME: TYPE: PHASE: REPEAT: CHG/VER:TGI NO: NONSKID ON MIDSHIP AY A 0 0/0

SHIP/HULL NO: SHIP/HULL NAME: PROJECT: SYSTEM: PLANT ID: CASREP CAT:

DDG-86 USS SHOUP KC1

CU PHASE TITLE: *F/O - REPLACE NONSKID SYSTEM ON 01 LEVEL FR BETWEEN 202 AND 329, PORT AND STBD

WORK CERTIFICATION SIGNATURES: DLs

COMPLETION OF WORK REVIEW: BADGE NO: SHOP/CODE: PHONE: DATE:

RECORDS REVIEW: BADGE NO: SHOP/CODE: PHONE: DATE:

FOUO Pg 1 of 3

OD01L089

PREPARING ACTIVITY: STATUS: APP WORKING STATUS:

PREPARED BY: CODE: PHONE: DATE:

KANO, DAISUKE 231A 3152430098 02-DEC-2024

APPROVED BY: CODE: PHONE: DATE:

NANBA, RYOUSUKE 231A 3152436141 02-DEC-2024

CONCURRED BY: CODE: PHONE: DATE:

REASON FOR WORK/NEED FOR CHANGE:

JCN:

OD01-L089

SPECIAL REQUIREMENTS:

CU PHASE DESCRIPTION:

ZONE MANAGER: ZONE: COMPARTMENT: LEVEL: FRAME: SIDE:

YAGINUMA, TAKEHIDE

JOB SUMMARY ID: TOT MAN HR.: TOT DUR: TOT JML COST: PLANNING ACCEPTANCE:

136A0001

1. SCOPE/PURPOSE:

1.1 Title: Nonskid System on 01 Level Frames between 202 and 329, Port and Starboard (Stbd); replace

1.2 Location of Work:

1.2.1 01 Level Weather, Frames between 202 and 329, Port and Stbd

1.3 Identification:

1.3.1 Quantity (3,055 SF), 01 Level Deck Plating, Frames between 202 and 329, including vertical surface up to height of 4 inches from deck in and around nonskid deck area, Port and Stbd

Remarks: The area excepts where rubber tile is installed.

1.4 Security Classification: None.

TGI Short Form

08-JAN-2025 1327

20.14.15.2.9020 (September 2024) (Continued) ICN: 38KC113601 KeyOp: A01

COMPONENT NAME: TYPE: PHASE: REPEAT: CHG/VER:TGI NO: NONSKID ON MIDSHIP AY A 0 0/0

SHIP/HULL NO: SHIP/HULL NAME: PROJECT: SYSTEM: PLANT ID: CASREP CAT:

DDG-86 USS SHOUP KC1

CU PHASE TITLE: *F/O - REPLACE NONSKID SYSTEM ON 01 LEVEL FR BETWEEN 202 AND 329, PORT AND STBD

FOUO Pg 2 of 3

CU PHASE DESCRIPTION (Cont.)

Ref.

No.

Document/Drawing Number DOCUMENT/DRAWING TITLE REV

CHG

NO.

CPY

REQ PARAGRAPH SECT PG CHPT

1.5 Initial Condition: None.

1.6 Contractor work start date: See TGI POP List

1.7 Contractor work completion date: See TGI POP List

2. PROCEDURE:

2.1 Accomplish the requirements of 009-32 of Ref. No. One, including Table 2, Line(s) 21, for each area listed in 1.3.1.

Application of nonskid system must conform to MIL-PRF-24667, Type V, Composition G.

2.1.1 Power tool clean to bare metal for each vertical surface. Accomplish each requirement of Surface Preparation Specification SSPC-SP 11 of Ref. No. 3.

2.2 Notes:

2.2.1 Planner: Code 231A D. Kano, 243-0098

2.2.2 Work Integration Manager (WIM): Code 333 T. Yaginuma, 080-5419-0598

2.2.3 JCN OD01-L089 is related to this TGI.

2.3 Government Furnished Material (GFM): None.

2.4 SRF-JRMC will provide the following service work: (TGI No. 38KC113601S02)

2.4.1 [C740] Crane and crane rigging service.

2.4.2 [X99E] Utility service, electrical.

2.4.3 [X99M] Utility service, including water supply and steam supply.

2.4.4 [C106.1] Safety inspection for SRF-JRMC employees.

2.4.5 [C106.2] Gas free inspection for SRF-JRMC employees.

2.4.6 [C133] QA inspection for (G) symbol(s).

08-JAN-2025 1327

20.14.15.2.9020 (September 2024) (Continued) ICN: 38KC113601 KeyOp: A01

COMPONENT NAME: TYPE: PHASE: REPEAT: CHG/VER:TGI NO: NONSKID ON MIDSHIP AY A 0 0/0

SHIP/HULL NO: SHIP/HULL NAME: PROJECT: SYSTEM: PLANT ID: CASREP CAT:

DDG-86 USS SHOUP KC1

CU PHASE TITLE: *F/O - REPLACE NONSKID SYSTEM ON 01 LEVEL FR BETWEEN 202 AND 329, PORT AND STBD

FOUO Pg 3 of 3

Ref.

No.

Document/Drawing Number DOCUMENT/DRAWING TITLE REV

CHG

NO.

CPY

REQ PARAGRAPH SECT PG CHPT

1 NSI FY-25 NAVSEA Standard Items - 1 N 2 LI FY-25 Local Standard Items - ORG N

3 TM SYSTEMS &

SPECIFICATIONS

SSPC Painting Manual Volume

- N

MATERIAL LIST

ITEM

NO.

PC

NO.

REF

NO.

M

C DESCRIPTION

STOCK

NUMBER

GENERIC

MATL

TYPE LVL QA

HAZ

MAT

DOC

NO.

QTY

REQD/

UNIT

QTY

USED/

UNIT

MATERIAL REFERENCES

REF

NO.

DOCUMENT/DRAWING NUMBER DOCUMENT/DRAWING TITLE

REV

ICN: 38KC113601 KEY OP: A01