ATTACHMENT V- Ceiling Lift Room Drawings.pdf
PDF 1 MB Posted
- Attached to
- Z1DA--Install Patient Ceiling Lift 583-26-509
- Solicitation number
- 36C25026Q0243
About this file
This document is an installation drawing set for ceiling lift systems at VAMC Indianapolis. The drawings specify detailed installation requirements for 17 rooms across the VA Medical Center facility, with layouts, dimensions, and structural specifications for ECS (Electrical Ceiling System) lift installations. The document includes installation details for various room configurations with safe working loads (SWL) ranging from 600 lbs to 1,000 lbs, requiring load testing at 1.5 times the SWL. Concrete slab structures must meet a minimum 4,000 PSI capacity, and all installations require 27.6 MPA (4,000 PSI) minimum tile ceiling capacity. The distributor is ARJO with representative Jim Bartram, dated December 13, 2024, reference number IR-096047.
The installation drawings cover multiple room types including patient care areas, surgical rooms, dialysis bays, and morgue facilities with specific track layouts, wall fixations, and hardware specifications. Key requirements include electrical power availability within 3 meters of charging stations, facility responsibility for relocating obstructions (vents, pipes, lights, sprinklers), and signed approval of all 28 drawing pages prior to installation. Important notes specify that Arjo reserves the right to modify track layouts, that the facility must verify adequate building structure capacity, and that any deviations from Arjo specifications must be documented and returned for as-built revisions. Hardware is completely included with installations per structural specifications, and initial load testing must be performed at the specified SWL multiplier before operational use.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25026Q0243 0003.docx | DOCX document | |
| Site visit sign in.pdf | ||
| 36C25026Q0243 0002.docx | DOCX document | |
| SOW update 2.19.26.pdf | ||
| 36C25026Q0243 0001.docx | DOCX document | |
| 36C25026Q0243.pdf | ||
| ATTACHMENT I - Arjo Brand Lift Single Source Determination.pdf | ||
| ATTACHMENT IV - WD.pdf | ||
| ATTACHMENT III - Instructions for VAAR 852.219-75.docx | DOCX document | |
| ATTACHMENT II- RFI Form.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DISTRIBUTOR :
REPRESENTATIVE :
DATE (DD-MMM-YYYY) :
REFERENCE # : PAGE :
INSTALLATION DRAWING
1. The ceiling minimum structure capacity must be able to support the load specified on the installation drawing.
2. Electrical power source outlet already available by the facility at a maximum distance of 3 meters from charging station.
3. Any obstructions such as vents, pipes, lights and sprinklers that could possibly be in the path of the ceiling lifts to be removed or relocated by the facility prior to installation.
4. Modifications of door headers by the facility.
5. Arjohuntleigh reserves the right to slightly modify the track layout if necessary.
6. See the "Agreed Conditions for the Installation of Ceiling Lifts" document included with this quote for important installation details.
7. Arjohuntleigh will not be held responsible for any damages, inconvenience, resulting from hitting any non visible conduits during our installation process.
8. Signed drawings are required prior to ordering and installation of ceiling lifts. This signature of each drawings confirms agreement of all the conditions listed above.
IMPORTANT NOTES
MY SIGNATURE BELOW VERIFIES THAT I HAVE:
Reviewed all ____ pages, with a total quantity of ____ rooms, for the approbation of layout for each room and the approbation of structure for each room. I verify that the answers below are accurate to the best of my knowledge and I understand that the quote produced is dependent upon the conditions below as well as this full drawing set.
· Is a load dock available? YES NO
· Can facility accept shipment and store until install begins? YES NO
· Will a drop trailer be needed? YES NO
· Is parking available on site? Is there a fee involved? YES NO
· Are there any installation time frame limitations?
What are they? YES NO
· Is a level of infectious control required? YES NO
If YES, then what level ___________________________
CUSTOMER
APPROVAL: DATE:
REVISION(S) DATE(S) (D-M-Y)
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
ARJO
JIM BARTRAM
1 / 28
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
Legend
IV
(*) Symbol may vary depending of equipment type
Track
ServZone
Track with gate
X-Y Trolley (Suspended)
X-Y Trolley (Embedded)
Turntable (Auto/Manual)
Track with gate reverse
Wall post
Wall bracket
Wall post side
Track with service zone
Track with wall fixation
Track with T-junction
Exchanger
Swivel pole
IV track
Curtain track
Sprinkler
Smoke detector
Electrical outlet
Ceiling light
Ceiling vent
Access trap required
Existing access trap
Additional items
Motor/charger location
SPRINKLER SHIM
ECS-CSTAT
X-Y alim. type + options
VAMC Indianapolis 1481 W 10th St Indianapolis, IN 46202
90"h90 h
E C
S E
C S
12"
6"
LISTING OF ROOM NUMBER(S):
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
2 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
ED 1126(#28)
A=96"
B=36"
D=6" ECS SYSTEM
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout
MUST be captured, marked on the drawings and returned to Arjo for an as built revision.*****
84"h90
84"h90 h
E C
S E
C S
12"
6"
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
3 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
ED 1125(#27)
A=96"
B=36"
D=6" ECS SYSTEM
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout
78"h90 h
E C
S E
C S
6"
12"
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
4 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
ED 1121(#26)
A=96"
B=36"
D=6" ECS SYSTEM
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout h
E C
S E
C S
6"
12"
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
5 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
ED 1169(#30)
A=96"
B=36"
D=6" ECS SYSTEM
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout h h
116" h140 Machined end
ECS-ECS
ServZone
6" 108"
6"
4"
4"
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
6 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
ED 1149(#5)
A=96"
B=36"
D=6" ECS SYSTEM
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTA
IN
CU
RT
AIN
CU
RT
AIN
CU
RT
AIN
CU
RT
AI
N
CURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAINCURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN
CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN
H
H
133"H140
ECS-ECS
72"H180
NOTE
REMOVING A SECTION OF LINEAR TRACK AND INSTALLING A NEW XY
SYSTEM AND ADDING 2 NEW DROPS TO EXISTING LINEAR PORTION THAT
WAS NOT REMOVED
EXISTING DROP
NEW DROPS
REMOVED LINEAR PORTION
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
7 / 28
1000LB [454KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout
MUST be captured, marked on the drawings and returned to Arjo for an as built revision.*****
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
ED A-1159
A=108"
B=24"
D=6" ECS SYSTEM
h h
102" h140 Machined end
ECS-ECS
ServZone
3"102"3"
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
8 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
ED 1114
A=96"
B=36"
D=6" ECS SYSTEM
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout
66"h90
66"h90 h
E C
S E
C S
12"
6"
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
9 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
ED 1115(#24)
A=96"
B=36"
D=6" ECS SYSTEM
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout h
E C
S E
C S
6"
12"
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
10 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
ED 1168(#29)
A=96"
B=36"
D=6" ECS SYSTEM
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout
CU
RT
AI
N
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
90"h90
90'h90 h
E C
S E
C S
12"
6"
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
11 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
ED 1165(#2)
A=96"
B=36"
D=6" ECS SYSTEM
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout h h
102"h140 Machined end
ECS-ECS
ServZone
3" 102" 3"
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
12 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
ED 1164(#1)
A=96"
B=36"
D=6" ECS SYSTEM
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout h h
NOTCHED 164"h180
ECS-ECS
12" 144" 60"
NOTCH TRAVERSE RAIL FOR CLEARANCE
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
13 / 28
1000LB [454KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout
MUST be captured, marked on the drawings and returned to Arjo for an as built revision.*****
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
ED 1146(#3)
A=96"
B=36"
D=6" ECS SYSTEM
h h
108" h140 Machined end
ECS-ECS
ServZone
6" 108" 6"
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
14 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
ED 1148(#4)
A=96"
B=36"
D=6" ECS SYSTEM
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN
CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN CURTAIN
84"h90
84"h90 h
E C
S E
C S
6"
11 1/2"
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
15 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
PACU A4151
A=108"
B=36"
D=6" ECS SYSTEM
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout h h
153"h140
ECS-ECS
132 1/2"
37 1/2"45 1/2"
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 1/4" = 1'
16 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
CYSTO C4034
A=96"
B=38"
D=6" ECS SYSTEM
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout h h
150"h140
ECS-ECS
h h
132"h140
ECS-ECS
h h
109"h140
ECS-ECS
h h
79" 118"
14"
94" 41 1/2"
10"
4"
4" 10"
14" 130" 107"
BAY 16
BAY 17
BAY 18
BAY 19
BAY 20
BAY 21
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 3/16" = 1'
17 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
B D
27.6 MPA [4000 PSI] MIN.
A
TILE
DIALYSIS BAYS 16, 20,21
A=103"
B=32"
D=6" ECS SYSTEM
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout
MUST be captured, marked on the drawings and returned to Arjo for an as built revision.***** un005140 Rectangle un005140 Callout installed under seperate project
132"H140
ServZone
ECS SYSTEM
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 3/16" = 1'
18 / 28
600LB [272KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LISTING OF ROOM NUMBER(S):
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
NOTE: ATTENTION INSTALLERS
*****Any deviation/changes from the Arjo specified installation details i.e. hardware, bracing, track layout
MUST be captured, marked on the drawings and returned to Arjo for an as built revision.*****
WALLFIXATION
A
MORGUE C-B121
A=94" ECS SYSTEM
WALL POST
STEEL STUDS
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 N/A
19 / 28
600LB [272KG]
900LB [408KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
THIS LAYOUT HAS BEEN PREPARED WITH SUPPLIED DATA. NOTE: CUTTING OF RAILS ON SITE ONLY
NOTES:
2. USE A RECOGNIZED INSTALLATION METHOD FOR EXPANDABLE "MOLLY" ANCHORS TYPE
3. MAX. TORQUE 10in - lb (1,13N.m.)
4. DRYWALL DAMAGE MAY OCCUR IF OVER TORQUE
5. STANDARD METHOD FOR SYMMETRICAL INSTALLATION ONLY (TWO OR MORE WALL POSTS)
6. ITEMS 1 TO 5 ARE INCLUDED IN KIT 700.12900 / 700.12910.
7. REFER TO MANUAL 001.12900.EN FOR ASSEMBLY INSTRUCTIONS FOR KIT 700.12900.
8. REFER TO MANUAL 001.12910.EN FOR ASSEMBLY INSTRUCTIONS FOR KIT 700.12910.
1 3 2
SEE NOTE 6 & 7
VOIR NOTE 6 & 7
FLOOR - PLANCHER
m i n
VUE DU DESSUS - TOP VIEW
VUE DE CÔTÉ - SIDE VIEW
SEE NOTE 7 & 8
VOIR NOTE 7 & 8
IMPERIAL STANDARD METHOD
6* WALL POST 3M KWIKTRAK 1
5 200.12950 PVC STRIP GRAY * 1
4 200.12900 WALL POST EXTRUSION * 1
3 000.03450 FLAT WASHER M6 (25 OD), ZINC PLATED STEEL * 9
2 000.03235 SCREW M6 X 80 HEX ZINC * 9
1 000.00660 GYPSUM ANCHOR M6 * 9
Item P/N Imperial Description (EN) Kit Qty
700.129XX
WALL POST KWIKTRAK MUST BE
IN CONTACT WITH THE FLOOR
IF THE WALL POST KWIKTRAK ALIGNS
ANYWHERE WITH A STUD IN THE WALL, ADD A
1/2" SELF-TAPPING SCREW AT THAT LOCATION
NOTE:
LIFT CAPACITY= 600 LBS
LIFT TRACK BY
ARJO
" MAX. DISTANCE
BETWEEN ANGLE
FITTING AND CEILING
14" MAX
10" MIN
EXISTING CONCRETE
SLAB MIN 3 1/8"
EQUAL +2" OF
CENTERLINE
OF STRUT
2 7 9 11
BRACE
"NOTE: ARJO GUARANTEES THE STRUCTURAL INTEGRITY OF THE TOTAL LIFT SYSTEM DESIGN, INCLUDING TRACK, BRACING, HANGERS, AND ALL CONNECTIONS TO THE BUILDING STRUCTURE. OUR DESIGN IS BASED ON THE REQUIREMENTS OF THE
CURRENT INTERNATIONAL BUILDING CODE (IBC) AND THE SESMIC LOADS OF THE REGION. THE FACILITY MUST VERIFY THE
ADEQUACY OF THE BUILDING STRUCTURE TO SUPPORT THE LOADS IMPOSED BY THE LIFT SYSTEM."
" NOMINAL
EMBEDMENT TYP.
121212
(X2) UPPER AND LOWER
CONNECTION FOR LATERAL
STANDARD TRACK INSTALLATION
L
U
S
P
T
M
A
X
U
N
I
S
T
R
U
P
X
***NOTE
EVERYTHING HIGHLIGHTED IN
BLUE IS PROVIDED BY ARJO AND
INSTALLED BY ARJO.****
FINISHED TILE CEILING
BY OTHERS
MIN 4000PSI CONCRETE SLAB STRUCTURE BY OTHERS
Item # Part # Description Qty
000.00394 THREADED ROD 3/8-16 X 10' ZINC 13
000.00402 LOCKNUT STOVER 3/8-16 ZINC 14
000.00405 NUT 3/8-16 ZINC 45
LUS-P1008 3
000.04430 FLAT WASHER M10 ZINC 5
200.11140 CEILING PLATE ø100MM 2
200.11170 BRACKET SHIM 12mm 1
000-01441 HILTI KB-TZ2 3/8 X 3 3/4 3
700.11100 TRACK BRACKET KWIKTRAK 1
LUS-P1068 UNISTRUT ANGLE 2
000.04435 TAB WASHER M10 1
1-5/8 x 10' SLOTTED CHANNEL
000.00425 LOCKWASHER 3/8" 4
000.04875 FLAT WASHER M12 4
16 LUS-P1000T
20"
200.11160
200.11150
BRACKET SHIM 3mm
BRACKET SHIM 1.5mm
000.00380 BOLT 3/8" - 16 X 11/2 "
LUS-P1063 1
UNISTRUT SQUARE PLATE
CHANNEL NUT W/SPRING 3/8"-16
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 N/A
20 / 28
600LB [272KG]
900LB [408KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
ARJO
" MAX. DISTANCE
BETWEEN ANGLE
FITTING AND CEILING
EXISTING CONCRETE
SLAB MIN 3 1/8"
2 7 9 11
BRACE
"NOTE: ARJO GUARANTEES THE STRUCTURAL INTEGRITY OF THE TOTAL LIFT SYSTEM DESIGN, INCLUDING TRACK, BRACING, HANGERS, AND ALL CONNECTIONS TO THE BUILDING STRUCTURE. OUR DESIGN IS BASED ON THE REQUIREMENTS OF THE
CURRENT INTERNATIONAL BUILDING CODE (IBC) AND THE SESMIC LOADS OF THE REGION. THE FACILITY MUST VERIFY THE
ADEQUACY OF THE BUILDING STRUCTURE TO SUPPORT THE LOADS IMPOSED BY THE LIFT SYSTEM."
" NOMINAL
EMBEDMENT TYP.
121212
(X2) UPPER AND LOWER
CONNECTION FOR LATERAL
STANDARD TRACK INSTALLATION
L
U
S
P
X
U
N
I
S
T
R
X
***NOTE
EVERYTHING HIGHLIGHTED IN
BLUE IS PROVIDED BY ARJO AND
INSTALLED BY ARJO.****
FINISHED TILE CEILING
BY OTHERS
MIN 4000PSI CONCRETE SLAB STRUCTURE BY OTHERS
Item # Part # Description Qty
000.00394 THREADED ROD 3/8-16 X 10' ZINC 13
000.00402 LOCKNUT STOVER 3/8-16 ZINC 14
000.00405 NUT 3/8-16 ZINC 45
LUS-P1008 3
000.04430 FLAT WASHER M10 ZINC 5
200.11140 CEILING PLATE ø100MM 2
200.11170 BRACKET SHIM 12mm 1
HDI DROP IN ANCHOR 1
700.11100 TRACK BRACKET KWIKTRAK 1
LUS-P1068 UNISTRUT ANGLE 2
000.04435 TAB WASHER M10 1
1-5/8 x 10' SLOTTED CHANNEL
000.00425 LOCKWASHER 3/8" 4
000.04875 FLAT WASHER M12 4
16 LUS-P1000T
20"
200.11160
200.11150
BRACKET SHIM 3mm
BRACKET SHIM 1.5mm
000.00380 BOLT 3/8" - 16 X 11/2 "
LUS-P1063 1
UNISTRUT SQUARE PLATE
CHANNEL NUT W/SPRING 3/8"-16
18 000-01441 HILTI KB-TZ2 3/8 X 3 3/4 1
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 N/A
21 / 28
600LB [272KG]
900LB [408KG]
ARJO
" MAX. DISTANCE
BETWEEN ANGLE
FITTING AND CEILING
BRACE
"NOTE: ARJO GUARANTEES THE STRUCTURAL INTEGRITY OF THE TOTAL LIFT SYSTEM DESIGN, INCLUDING TRACK, BRACING, HANGERS, AND ALL CONNECTIONS TO THE BUILDING STRUCTURE. OUR DESIGN IS BASED ON THE REQUIREMENTS OF THE
CURRENT INTERNATIONAL BUILDING CODE (IBC) AND THE SESMIC LOADS OF THE REGION. THE FACILITY MUST VERIFY THE
ADEQUACY OF THE BUILDING STRUCTURE TO SUPPORT THE LOADS IMPOSED BY THE LIFT SYSTEM."
121212
2 7 9 11
BRACE
(X2) UPPER AND LOWER
CONNECTION FOR LATERAL
" MIN.
EMBEDMENT
TYP.
14" MAX
10" MIN
EQEQ
" MIN.
EMBEDMENT
TYP.
EXISTING CONCRETE DECK
3,000 PSI MINIMUM
4" VERY LIGHT CONCRETE VERMICULITE
FINISHED TILE CEILING
BY OTHERS
***NOTE
EVERYTHING HIGHLIGHTED IN
BLUE IS PROVIDED BY ARJO AND
INSTALLED BY ARJO.****
Item # Part # Description Qty
000.00394 THREADED ROD 3/8-16 X 10' ZINC 53
000.00402 LOCKNUT STOVER 3/8-16 ZINC 14
000.00405 NUT 3/8-16 ZINC 105
000.04430 FLAT WASHER M10 ZINC 5
200.11140 CEILING PLATE ø100MM 3
200.11170 BRACKET SHIM 12mm 1
000-01441 HILTI KBTZ 2 3/8 X 3 3/4 3
700.11100 TRACK BRACKET KWIKTRAK 1
LUS-P1068 UNISTRUT ANGLE 2
000.04435 TAB WASHER M10 1
000.00425 LOCKWASHER 3/8" 8
000.04875 FLAT WASHER M12 6
200.11160
200.11150
BRACKET SHIM 3mm
BRACKET SHIM 1.5mm
1-5/8 x 10' SLOTTED CHANNEL16 LUS-P1000t
000.00380 BOLT 3/8" - 16 X 1 1/2"
3/8NC16 X 1 3/4 COUPLING NUT17 000.00410 2
SQUARE PLATE18 LUS-P1063 7
46"
19 3(20")1-5/8 x 10' SLOTTED CHANNELLUS-P1000T
LUS-P1008 CHANNEL NUT W SPRING 3/8-16
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 N/A
22 / 28
600LB [272KG]
900LB [408KG]
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 N/A
23 / 28
600LB [272KG]
900LB [408KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LATERAL BRACE REQUIREMENTS REV-3
LEGEND
LATERAL
BRACE
TRACK
BRACKET
TRACK
BRACKET JOINT
4 TRACKS SECTION
3 TRACK BRACKETS JOINT
9 LATERAL BRACES
1 TRACK SECTION
0 TRACK BRACKET JOINT
3 LATERAL BRACES
2 TRACKS SECTION
1 TRACK BRACKET JOINT
4 LATERAL BRACES
3 TRACKS SECTION
2 TRACK BRACKETS JOINT
6 LATERAL BRACES
- MINIMUM 3 LATERAL BRACES.
- NUMBER OF LATERAL BRACE = (NUMBER OF TRACK BRACKET JOINT X 2) + 2.
POSSIBLE ANCHOR LATERAL TO THE CEILING OR TO THE WALL
ACCEPTABLE ANGLE
LATERAL BRACE
LUS-P1000T
FLAT WASHER M12
000.04875
CONCRETE
HILTI KBTZ2 3/8 X 3 3/4
000-01441
BELOW CEILING TRACK
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 N/A
24 / 28
600LB [272KG]
900LB [408KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
MAX. STRUT BRIDGE "SPAN"
STRUT
LIFT CAPACITY
P1000T
P1000
P5500T
P5500
P5501
P5001
P1001
P5000
600#
1'-8"
2'-0"
3'-3"
4'-0"
5'-4"
4'-10"
8'-6"
10'-4"
STRUT BRIDGE PER TABLE
BELOW (SLOT- FACE DOWN)
"SPAN"
REF. TABLE BELOW
DUCT, PIPE
OR OTHER
OBSTRUCTION
AS OCCURS
STRUT TO BUILDING STRUCTURE
REF. PLANS AND DETAILS
B
R
A
C
E
O
S
R
U
C
T
U
R
E
R
E
F
L
A
N
D
D
E
T
A
I
L
S
BRIDGE DETAIL
Item # Part # Description Qty
000.00394 THREADED ROD 3/8-16 X 10' ZINC 21
000.00405 NUT 3/8-16 ZINC 6
TYP. ROD
HANGER PER
PLANS AND
DETAILS
SQUARE PLATE 3/8"
"NOTE: ARJO GUARANTEES THE STRUCTURAL INTEGRITY OF THE TOTAL LIFT SYSTEM DESIGN, INCLUDING TRACK, BRACING, HANGERS, AND ALL CONNECTIONS TO THE BUILDING STRUCTURE. OUR DESIGN IS BASED ON THE REQUIREMENTS OF THE
CURRENT INTERNATIONAL BUILDING CODE (IBC) AND THE SESMIC LOADS OF THE REGION. THE FACILITY MUST VERIFY THE
ADEQUACY OF THE BUILDING STRUCTURE TO SUPPORT THE LOADS IMPOSED BY THE LIFT SYSTEM."
LUS-P1008 CHANNEL NUT W SPRING 3/8 23
VERIFY IN FIELD
LUS-P1063
LIFT CAPACITY= 1000 LBS
ARJO
3/4" MAX. DISTANCE
BETWEEN ANGLE
FITTING AND CEILING
14" MAX
10" MIN
EXISTING CONCRETE
SLAB MIN 3 1/8"
EQUAL +2" OF
CENTERLINE
OF STRUT
2 7 9 11
BRACE
"NOTE: ARJO GUARANTEES THE STRUCTURAL INTEGRITY OF THE TOTAL LIFT SYSTEM DESIGN, INCLUDING TRACK, BRACING, HANGERS, AND ALL CONNECTIONS TO THE BUILDING STRUCTURE. OUR DESIGN IS BASED ON THE REQUIREMENTS OF THE
CURRENT INTERNATIONAL BUILDING CODE (IBC) AND THE SESMIC LOADS OF THE REGION. THE FACILITY MUST VERIFY THE
ADEQUACY OF THE BUILDING STRUCTURE TO SUPPORT THE LOADS IMPOSED BY THE LIFT SYSTEM."
" NOMINAL
EMBEDMENT TYP.
121212
(X2) UPPER AND LOWER
CONNECTION FOR LATERAL
STANDARD TRACK INSTALLATION
L
U
S
P
X
U
N
I
S
T
R
X
***NOTE
EVERYTHING HIGHLIGHTED IN
BLUE IS PROVIDED BY ARJO AND
INSTALLED BY ARJO.****
FINISHED TILE CEILING
BY OTHERS
MIN 4000PSI CONCRETE SLAB STRUCTURE BY OTHERS
Item # Part # Description Qty
000.00394 THREADED ROD 3/8-16 X 10' ZINC 13
000.00402 LOCKNUT STOVER 3/8-16 ZINC 14
000.00405 NUT 3/8-16 ZINC 45
LUS-P1008 3
000.04430 FLAT WASHER M10 ZINC 5
200.11140 CEILING PLATE ø100MM 2
200.11170 BRACKET SHIM 12mm 1
000-01441 HILTI KB-TZ2 3/8 X 3 3/4 3
700.11100 TRACK BRACKET KWIKTRAK 1
LUS-P1068 UNISTRUT ANGLE 2
000.04435 TAB WASHER M10 1
1-5/8 x 10' SLOTTED CHANNEL
000.00425 LOCKWASHER 3/8" 4
000.04875 FLAT WASHER M12 4
16 LUS-P1000T
20"
200.11160
200.11150
BRACKET SHIM 3mm
BRACKET SHIM 1.5mm
000.00380 BOLT 3/8" - 16 X 11/2 "
LUS-P1063 1
UNISTRUT SQUARE PLATE
CHANNEL NUT W/SPRING 3/8"-16
- ALL HARDWARE INCLUDED.
(ACCORDING TO STRUCTURE)
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 N/A
25 / 28
1000LB [454KG]
1500LB [681KG]
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 N/A
26 / 28
1000LB [454KG]
1500LB [681KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
LATERAL BRACE REQUIREMENTS REV-3
LEGEND
LATERAL
BRACE
TRACK
BRACKET
TRACK
BRACKET JOINT
4 TRACKS SECTION
3 TRACK BRACKETS JOINT
9 LATERAL BRACES
1 TRACK SECTION
0 TRACK BRACKET JOINT
3 LATERAL BRACES
2 TRACKS SECTION
1 TRACK BRACKET JOINT
4 LATERAL BRACES
3 TRACKS SECTION
2 TRACK BRACKETS JOINT
6 LATERAL BRACES
- MINIMUM 3 LATERAL BRACES.
- NUMBER OF LATERAL BRACE = (NUMBER OF TRACK BRACKET JOINT X 2) + 2.
POSSIBLE ANCHOR LATERAL TO THE CEILING OR TO THE WALL
ACCEPTABLE ANGLE
LATERAL BRACE
LUS-P1000T
FLAT WASHER M12
000.04875
CONCRETE
HILTI KBTZ2 3/8 X 3 3/4
000-01441
BELOW CEILING TRACK
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 N/A
27 / 28
1000LB [454KG]
1500LB [681KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
MAX. STRUT BRIDGE "SPAN"
STRUT
LIFT CAPACITY
P1000T
P1000
P5500T
P5500
P5501
P5001
P1001
P5000
2'-1"
2'-9"
3'-9"
3'-6"
6'-6"
7'-6"
1000#
1'-1"
1'-6"
STRUT BRIDGE PER TABLE
BELOW (SLOT- FACE DOWN)
"SPAN"
REF. TABLE BELOW
DUCT, PIPE
OR OTHER
OBSTRUCTION
AS OCCURS
STRUT TO BUILDING STRUCTURE
REF. PLANS AND DETAILS
B
R
A
C
E
O
R
U
C
T
U
R
E
R
E
F
L
A
D
D
E
T
A
I
L
S
TWIN ROD AT
MS 1000 LIFTS
BRIDGE DETAIL
Item # Part # Description Qty
000.00394 THREADED ROD 3/8-16 X 10' ZINC 21
000.00405 NUT 3/8-16 ZINC 6
TYP. ROD
HANGER PER
PLANS AND
DETAILS
SQUARE PLATE 3/8"
"NOTE: ARJO GUARANTEES THE STRUCTURAL INTEGRITY OF THE TOTAL LIFT SYSTEM DESIGN, INCLUDING TRACK, BRACING, HANGERS, AND ALL CONNECTIONS TO THE BUILDING STRUCTURE. OUR DESIGN IS BASED ON THE REQUIREMENTS OF THE
CURRENT INTERNATIONAL BUILDING CODE (IBC) AND THE SESMIC LOADS OF THE REGION. THE FACILITY MUST VERIFY THE
ADEQUACY OF THE BUILDING STRUCTURE TO SUPPORT THE LOADS IMPOSED BY THE LIFT SYSTEM."
LUS-P1008 CHANNEL NUT W SPRING 3/8 23
VERIFY IN FIELD
LUS-P1063
QUANTITY OF ROOMS:
DRAWN BY :
REFERENCE # : PAGE :
SCALE :
DATE CREATED (DD-MMM-YYYY) :
SWL WORKING LOAD BELOW LIFT:
INITIAL LOAD TEST TO BE DONE @ SWL x 1.5
VAMC INDIANAPOLIS
IR-096047
13-DEC-2024
un001629 N/A
28 / 28
Z
1000LB [454KG]
1500LB [681KG]
Rev1-un001629 31-JAN-2025
Rev2-un001629 11-SEP-2025
EMBEDDED X-Y CONFIG.
700-11228 - ECS to ECS wiring kit
FLUSH X-Y CONFIG.
STANDARD X-Y CONFIG.
WALL MOUNTED X-Y CONFIG.
ECS - ECS CHARGING
CONTACT BOX (3X)
ECS ON FIXED RAIL
ECS ON MOVING RAIL
V5 Duo
MS600 ecs
MS2 ecs
MS440
V5 Duo
MS600 ecs
MS2 ecs
MS440
V5 Duo
MS600 ecs
MS2 ecs
MS440
V5 Duo
MS600 ecs
MS2 ecs
MS440
| Sheets and Views |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-Title |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-02 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-03 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-04 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-05 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-06 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-06 (2) |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-07 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-08 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-09 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-10 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-11 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-12 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-13 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-15 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-18 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-19 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-23 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-X-31210.01-S1 (4) |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-X-31210.01-S1 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-X-31210.01-S1 (2) |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-X-31210.01-S1 (3) |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-X-31210.01-LateralUS |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-X-31210.01-LateralUS (2) |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-X-31210.03-S1 |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-X-31210.03-LateralUS |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-X-31210.03-LateralUS (2) |
| IR-096047 QC-12132401 VAMC Indianapolis - Rev 2-X-BB-BD-ECS.ECS-X-ECS-ECS |
File details come from the government source that posted it. Updated .