Attachment_-_Submittal_List.pdf
PDF 112 KB Posted
- Attached to
- Fan Coil Unit Replacement Federal contract opportunity
- Solicitation number
- 140P6425B0004
About this file
This document is a Submittal List for the FILA Fan Coil Replacement project for the National Park Service's Denver Service Center, dated 1-27-21. The submittal list details comprehensive documentation requirements across multiple specification sections, including Division 1 Preconstruction Conference Submittals, Selective Demolition Submittals, Access Doors and Frames, and various HVAC-related submittals such as meters, gauges, valves, piping insulation, and fan coil units. The document requires contractors to provide informational and action submittals like product data, shop drawings, samples, coordination drawings, quality control reports, sustainable design submittals, equipment warranties, and field quality control reports for different project components. The Project Management Information System (PMIS) Number for this project is 258437C, and the submittal list specifies which engineering disciplines (architectural, civil, structural, mechanical, electrical) need to review each submission.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Site_Visit_Attendees_List_0001.pdf | ||
| Sol_140P6425B0004_Amd_0001.pdf | ||
| Questions_and_Answers_0001.pdf | ||
| Revised_Drawings_-_12_May_2025_0001.pdf | ||
| Sol_140P6425B0004.pdf | ||
| Bid_Schedule_-_Fan_Coil_Replace.pdf | ||
| Attachment_-_Construction_Contract_Admin.pdf | ||
| Attachment_-_Drawings-Pictures.pdf | ||
| Attachment_-_Notice_to_Contractors.pdf | ||
| Wage_Determination_-_Stark_Co.pdf | ||
| Attachment_-_Limitations_on_Subcontracting_Report.xlsx | XLSX spreadsheet | |
| Bid_Schedule_-_Fan_Coil_Replace.xlsx | XLSX spreadsheet | |
| Specifications_-_Fan_Coil_Replace.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FILA Fan Coil Replacement Submittal List National Park Service (NPS) - Denver Service Center (DSC) | 1-27-21
SUBMITTAL LIST ACTION SUBMITTAL
REVIEW ESTIMATE
Park Acronym/Project Management Information System (PMIS) Number: (Complete this portion for Architect / Engineer (A/E) Project Title: FILA Fan Coil Replacement construction service task order negotiation.)
SUBMITTAL REQUIREMENTS ARCHITECT / ENGINEER REVIEW TIME
(Indicate with X) (Indicate in whole or partial hours.)
INFORMATIONAL ACTION
SP
EC
IF
IC
AT
IO
N S
EC
TI
O N
PA
R
AG
R
AP
H
N U
M
BE
R
DESCRIPTION
C
ER
TI
FI
C
AT
IO
N
S O
R
LA
BO
R
AT
O R
Y
TE
ST
S
R
EP
O R
TS
O
R C
AL
C
U
LA
TI
O
N S
O R
P
LA
N
M
AN
U
FA
C
TU
R
ER
D
AT
A
AN
D
IN
ST
R
U C
TI
O
N S
O
TH
ER
SA
M
PL
ES
SH
O
P D
R
AW
IN
G
S
M
AN
U
FA
C
TU
R
ER
D
AT
A
AN
D
IN
ST
R
U C
TI
O
N S
O
TH
ER
AR
C
H
IT
EC
T
C
IV
IL
E
N G
IN
EE
R
ST
R
U C
TU
R
AL
E
N G
IN
EE
R
M
EC
H
AN
IC
AL
E N
G
IN
EE
R
EL
EC
TR
IC
AL
E
N G
IN
EE
R
PR
O
JE
C
T M
AN
AG
ER
C
O R
D
IN
AT
IO
N
LA
N
D
SC
AP
E
AR
C
H
IT
EC
T
Division 1 Submittals 01 10 00 Preconstruction Conference Submittals
9.1.C.1 Letter Designating Project Superintendent X 9.1.C.2 Construction Schedule X 9.1.C.3 Schedule of Values X 9.1.C.4 Accident Prevention (Safety) Plan (APP) X 9.1.C.5 Subcontractors List X 9.1.C.6 Subcontractor Certification Compliance X 9.1.C.7 Quality Control Plan X
02 41 19 Selective Demolition Submittals 1.5.A Proposed Protection Measures X 1.5.B Schedule of Selective Demolition Activities X 1.5.C Predemolition Photographs or Video X 1.5.D Warranties Information X
08 31 13 Access Doors and Frames Product Data X Samples X Product Schedule X
230519 Meters and Gauges for HVAC Piping 1.2A Product Data X 1.2B Shop Drawings X 1.3A Product Certificates X
230523 General Valves for HVAC Piping 1.2A Product Data X
230548 Vibration and Seismic Controls for HVAC 1.2A Product Data X
258437C
Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 1 of 3
SUBMITTAL LIST ACTION SUBMITTAL
REVIEW ESTIMATE
Park Acronym/Project Management Information System (PMIS) Number: (Complete this portion for Architect / Engineer (A/E) Project Title: FILA Fan Coil Replacement construction service task order negotiation.)
SUBMITTAL REQUIREMENTS ARCHITECT / ENGINEER REVIEW TIME
(Indicate with X) (Indicate in whole or partial hours.)
INFORMATIONAL ACTION
SP
EC
IF
IC
AT
IO
N S
EC
TI
O N
PA
R
AG
R
AP
H
N U
M
BE
R
DESCRIPTION
C
ER
TI
FI
C
AT
IO
N
S
R
AT
O R
Y
TE
ST
S
R
EP
O R
TS
O
R C
AL
C
U
LA
TI
O
N S
O R
P
LA
N
M
AN
U
FA
C
TU
R
ER
D
AT
A
AN
D
IN
ST
R
U C
TI
O
N S
O
TH
ER
SA
M
PL
ES
SH
O
P D
R
AW
IN
G
S
M
AN
U
FA
C
TU
R
ER
D
AT
A
AN
D
IN
ST
R
U C
TI
O
N S
O
TH
ER
AR
C
H
IT
EC
T
C
IV
IL
E
N G
IN
EE
R
ST
R
U C
TU
R
AL
E
N G
IN
EE
R
M
EC
H
AN
IC
AL
E N
G
IN
EE
R
EL
EC
TR
IC
AL
E
N G
IN
EE
R
PR
O
JE
C
T M
AN
O R
D
IN
AT
IO
N
LA
N
D
SC
AP
E
AR
C
H
IT
EC
T
258437C
1.2B Shop Drawings X 1.3A Coordination Drawings X 1.3B Welding Certificates X 1.3C Field Quality Control Reports X
230553 Identification for HVAC Piping and Equipment 1.2A Product Data X 1.2B Samples X 1.3C Equipment Label Schedule X
230593 Testing, Adjusting, and Balancing for HVAC 1.3A Qualification Data X 1.3B Contract Documents Examination Report X 1.3C Strategies and Procedures Plan X 1.3D System Readiness Checklist X 1.3E Examination Report X 1.3F Certified TAB Report X 1.3G Stample Report Forms X 1.3H Instrumentation Calibration Reports X
230719 HVAC Piping Insulation 1.2A Product Data X 1.2B Sustainable Design Submittals X 1.2C Shop Drawings X 1.2D Samples X 1.3A Qualification Data X 1.2B Material Test Reports X 1.3C Field Quality Control Reports X
232113 Hydronic Piping 1.2A Product Data X 1.2B Sustainable Design Submittals X 1.2C Delegated Design Submittal X 1.3A Coordination Drawings X 1.3B Qualification Data X
232116 Hydronic Piping Specialties 1.2A Product Data X
Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 2 of 3
SUBMITTAL LIST ACTION SUBMITTAL
REVIEW ESTIMATE
Park Acronym/Project Management Information System (PMIS) Number: (Complete this portion for Architect / Engineer (A/E) Project Title: FILA Fan Coil Replacement construction service task order negotiation.)
SUBMITTAL REQUIREMENTS ARCHITECT / ENGINEER REVIEW TIME
(Indicate with X) (Indicate in whole or partial hours.)
INFORMATIONAL ACTION
SP
EC
IF
IC
AT
IO
N S
EC
TI
O N
PA
R
AG
R
AP
H
N U
M
BE
R
DESCRIPTION
C
ER
TI
FI
C
AT
IO
N
S
R
AT
O R
Y
TE
ST
S
R
EP
O R
TS
O
R C
AL
C
U
LA
TI
O
N S
O R
P
LA
N
M
AN
U
FA
C
TU
R
ER
D
AT
A
AN
D
IN
ST
R
U C
TI
O
N S
O
TH
ER
SA
M
PL
ES
SH
O
P D
R
AW
IN
G
S
M
AN
U
FA
C
TU
R
ER
D
AT
A
AN
D
IN
ST
R
U C
TI
O
N S
O
TH
ER
AR
C
H
IT
EC
T
C
IV
IL
E
N G
IN
EE
R
ST
R
U C
TU
R
AL
E
N G
IN
EE
R
M
EC
H
AN
IC
AL
E N
G
IN
EE
R
EL
EC
TR
IC
AL
E
N G
IN
EE
R
PR
O
JE
C
T M
AN
O R
D
IN
AT
IO
N
LA
N
D
SC
AP
E
AR
C
H
IT
EC
T
258437C
238219 Fan Coil Units 1.2A Product Data X 1.2B Sustainable Design Submittals X 1.2C Shop Drawings X 1.3A Coordination Drawings X 1.3B Seismic Qualification Certificates X 1.3C Field Quality Control Reports X 1.3D Sample Warranty X
Total: 0 0 0 0 0 0 0
Submittal List with Review Estimate Template | National Park Service (NPS) - Denver Service Center (DSC) page 3 of 3
Template
File details come from the government source that posted it. Updated .