ATTACHMENT PP - Fernstrum Grid Cooler Installation and Maintenance Manual.pdf
PDF 1 MB Posted
- Attached to
- IFB 160941 JS Ferry Surry Shipyard Package
- Solicitation number
- IFB-126120
- Issued by
- Southampton County, Virginia
About this file
Summary: GRIDCOOLER Keel Cooler Installation and Maintenance Manual
This document is a technical installation and maintenance manual for R.W. Fernstrum & Company's GRIDCOOLER Keel Cooler product, a marine heat exchange system designed for vessel cooling applications. The manual provides comprehensive guidance on planning, locating, and installing keel coolers on various vessel types, including displacement vessels, planing vessels, and generator sets. Installation considerations include proper hull location (parallel to skeg or keel with full seawater flow), mounting specifications for different hull materials (copper/nickel and aluminum), and plumbing configurations. The manual specifies torque requirements for copper/nickel installations ranging from 20-250 foot-pounds depending on nozzle size, and aluminum installations from 20-150 foot-pounds. Special installation options covered include cofferdam installations with compression gaskets, Z-option flange-mounted systems, and L-option support plate configurations that require no through-hull penetration.
The manual addresses maintenance and troubleshooting procedures to ensure optimal heat transfer efficiency, including exterior cleaning methods (scraping, high-pressure water blasting, and sandblasting at maximum 90 psi with 40-60 grit media), interior radiator flush procedures, and zinc electrode replacement protocols. Repair procedures are documented for both copper/nickel units (using 56% silver braze wire) and aluminum units (using R5554 aluminum filler rod). The limited warranty covers copper/nickel units for two years and aluminum units for ninety days from delivery, provided units are returned prepaid to the manufacturer's facility within specified timeframes. The warranty excludes labor, transportation, haul-out, launch, towing, storage, and other associated costs, and is void if repairs or alterations have been made without manufacturer authorization.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R.W. Fernstrum & Company
Installation and Maintenance Manual Form 175
GRIDCOOLER®
KEEL COOLER
Maintenance Manual 7/10/12 10:11 AM Page 2 installation and maintenance manual form 170 index
TABLE OF CONTENTS
Section Title
1.0 Planning & Location
1.1 Determining Proper Locations – Typical
1.2 Determining Proper Locations –
Displacement Vessels
1.3 Determining Proper Locations –
Planing Vessels
1.4 Improper (Not Recommended) Locations . .2
1.5 Mounting Considerations - Typical . . . . . . . .2-3
1.6 Mounting Considerations –
Displacement Vessels
1.7 Mounting Considerations –
Planing Vessels
1.8 Bonding & Isolation
2.0 Installation
2.1 Making Holes
2.2 Fitting Up
2.3 Copper Nickel Installation . . . . . . . . . . . . . . . .4-5
2.4 Aluminum Installations
2.5 Plumbing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6
2.6 Filling & Testing
3.0 Special Installations
3.1 Cofferdam Installation with
Compression Gaskets
3.2 Z OPTION™ Installations
3.3 L OPTION™ Support Plate Installation
3.4 Mounting Copper/Nickel Coolers on
Aluminum Hulls
4.0 Forming the GRIDCOOLER® Keel Cooler .11
4.1 Bending a GRIDCOOLER Keel Cooler
4.2 Twisting a GRIDCOOLER Keel Cooler
5.0 Performance Issues
5.1 Wire Reinforced Rubber Hose
5.2 Piping
Section Title
5.3 Jacketwater
5.4 Thermostat
5.5 Jacketwater Pump
5.6 Air in the System
5.7 Foreign Matter
5.8 Expansion Tank
5.9 External Coating
5.10 Water Aeration
5.11 Moored at Dock
5.12 Placement
5.13 Mounting Gaskets
5.14 Glycol
5.15 Crushed Tubes
5.16 Blown Tubes
5.17 Marine Growth
5.18 Oil Deposits
5.19 Mineral Deposits
6.0 Maintenance
6.1 Exterior
6.2 Interior
6.3 Pressure Testing
7.0 Repair
7.1 Straightening
7.2 Copper/Nickel GRIDCOOLER Keel
Cooler Repairs
7.3 Aluminum GRIDCOOLER Keel
Cooler Repairs
7.4 Temporary Repair
7.5 Couplings Repair
8.0 Stray-Current Corrosion
9.0 Parts . . . . . . . . . . . . . . . . . . . . . . . . . .16-17
10.0 Warranty
11.0 Recommendation Form
Maintenance Manual 7/10/12 10:11 AM Page 3 form 175
Maintenance Manual 7/10/12 10:11 AM Page 4 section 1 PLANNING & LOCATION installation and maintenance manual form 170 page 1
PLANNING & LOCATION
1.0 PLANNING & LOCATION
To function properly, the FERNSTRUM® GRIDCOOLER® Keel Cooler must be properly located on your vessel’s hull. Please consider the following before installing your keel cooler on most types of vessels. For additional details on displacement or planning hulls, refer to the appropriate sections:
1.1 DETERMINING PROPER LOCATION –
TYPICAL
1.1.1 Sea water must flow over the entire length of the unit.
1.1.2 Always install the unit parallel, not transverse, to the skeg or keel. See Figures 1 & 2.
FIG. 1 External type installation with E1 OPTION end-mounted zinc anodes using fairing blocks for protection and streamlining.
FIG. 2 Recess type installation with E1 OPTION end-mounted zinc anodes for reduced drag in high-speed craft.
1.1.3 When using a two-circuit cooling system, consisting of a high temperature jacketwater circuit and a low temperature aftercooler circuit, make certain the aftercooler circuit cooler is placed forward of the jacketwater circuit cooler.
When room allows, they can be installed side by side with the aftercooler circuit lower on the hull (i.e. closer to the skeg or keel) and a divider plate between the high and low temperature units.
1.1.4 When the GRIDCOOLER unit is used on a generator set or
if your application requires sizing for a hull speed of 0 knots, make sure that sea water can freely circulate past the cooler tubes. Do not recess a generator set unit on the bottom of a flat bottom boat unless the hull section where the unit will be mounted inclines a minimum of 20 degrees (from forward to aft) to avoid entrapping raw hot water around the tubes. See Figure 3.
1.2 DETERMINING PROPER LOCATION –
DISPLACEMENT VESSELS
1.2.1 On vessels performing pushing, towing, dragging or pulling operations, install the unit as near to the propeller as possible (but not directly above it) to take advantage of its slip-stream during extreme towing operations.
See Figure 3.
FIG. 3 Recessed installation is made by welding in a box-shaped recess in the underside of the hull.
Note aft end of recess is tapered to prevent hot water entrapment.
1.2.2 When installing a unit on the side of a hull, position it well below the water line to avoid aerated surface water. Take the bow wave into consideration. Aeration reduces heat transfer and can cause overheating. See Figure 4.
Maintenance Manual 7/10/12 10:11 AM Page 5
FIG. 6 Example of external guarding installation and maintenance manual form 170 page 2
PLANNING & LOCATION
FIG. 4 Side mounted coolers well below water line.
1.3 DETERMINING PROPER LOCATION –
PLANING VESSELS
1.3.1 For planing hull vessels, locate the unit as far aft as possible to avoid aeration.
1.4 IMPROPER (NOT RECOMMENDED) LOCATIONS
1.4.1 The area of the hull where the GRIDCOOLER® Keel Cooler
is installed must not vibrate or flex severely.
1.4.2 To eliminate unnecessary stress and vibration on the
cooler, do not locate the unit directly below engine mounts or above the propeller(s).
1.4.3 Make sure that hot water is not discharged on or near
the unit.
1.4.4 Do not locate the unit on the front 1/3 of the hull for displacement hulls. Bowthruster coolers could be an exception, depending on the vessel.
1.4.5 The GRIDCOOLER Keel Cooler is designed to be mounted
directly to the hull. Do not mount the unit to any external structure without first consulting the factory.
1.5 MOUNTING CONSIDERATIONS – TYPICAL
1.5.1 Some classed vessels (ABS or Coast Guard, for example)
may require cofferdams, check with your local officials for more information. For this type of installation, see Cofferdam Installation in Section 3.1.
1.5.2 The GRIDCOOLER unit can be canted from the hull
(sideways) to vertically align the nozzles. This can reduce interference problems with stringers on cofferdam installations. See Figure 5.
(referred to section 3.1 for cofferdam installation)
FIG. 5 Canted Installation with Cofferdam.
1.5.3 If the unit is recessed into the hull, make sure that it has a 1-1/2 in. (38 mm) minimum clearance on all sides (this does not include between the hull and the top of the cooler). The recess should be no deeper than 1/2 in. (13 mm) plus the hull projection (listed on installation drawing) of the cooler.
1.5.4 In extreme cases, where logs, debris, or dragging bottom may endanger the unit, a protective guard may be mounted over the unit. Make certain the grill guard does not cover more than 25% of the face opening. For examples of protective guards and different installations that have been used, see Figures 6 and 7.
Maintenance Manual 7/10/12 10:11 AM Page 6 installation and maintenance manual form 170 page 3
PLANNING & LOCATION
FIG. 7 Side mounted coolers
1.5.5 The unit can be bent to conform to the hull. The bending can be done at the yard or by R. W. Fernstrum & Company.
Contact us if you are considering bending a unit. See Section 4.0 – Forming the GRIDCOOLER® Keel Cooler.
1.6 MOUNTING CONSIDERATIONS –
DISPLACEMENT VESSELS
1.6.1 Owners of vessels with displacement hulls moving at less than 10 knots may find an external mounting with fairing blocks to their advantage; provided there isn’t much chance of the unit being damaged in their operating environment
1.6.2 When recessing the unit into the side of the hull for
generator sets and/or equipment operating at dockside, angle the top of the recess box to allow convection current over the cooler. See Figure 8.
FIG. 8 Side Mounted Recess.
NOTE: Recess box with angled top suggested for generator set and equipment operating at dock side only. NOT required for propulsion engines.
1.6.3 When installing a multiple-pass unit on an incline, make sure that the nozzles are at the high end to avoid air entrapment. See Figure 9.
1.6.4 If coolers must be installed with the nozzles at the low end, special units can be ordered with additional vents in the stud end of the cooler.
FIG. 9 U-Flow unit with E1 OPTION end mounted zinc anodes mounted on rake of vessel.
1.6.5 If side plates and fairing blocks are used, make sure that the side plates are scalloped (notched) out so they will not entrap water. Fairing blocks are most effective when installed with a 4 to 1 slope. See Figures 1 & 6.
1.7 MOUNTING CONSIDERATIONS –
PLANING VESSELS
1.7.1 If you aren’t sure as to whether or not you should recess the unit, we recommend using a recess on planing hulls and vessels moving at 10 or more knots.
1.7.2 High speed applications (10+ knots) can reduce the 1-1/2
in. clearance in section 1.3.4 to 1/2 in. minimum due to increased raw water flow over the cooler at high speed.
1.7.3 High speed applications and others that use E1 OPTION™
coolers should take into consideration the removal and replacement of zinc electrodes when sizing the length of a recess. See Figure 2.
1.8 BONDING OR ISOLATION
TO MINIMIZE CORROSION
1.8.1 It is recommended that the installer consult with a
corrosion engineer to review the corrosion protection system of the vessel to determine the best mode of installation for their particular situation.
Typically it is common practice to isolate the heat exchanger from the hull. This ensures that the antifouling property of the copper nickel is at full potential. However, there are other variables that may effect the decision whether to isolate or bond the unit.
Maintenance Manual 7/10/12 10:11 AM Page 7 form 175 cary.klager Line
FIG. 10 Mounting Parts Placement
NOTE: IF CONCAVE WASHERS ARE USED,
MAKE SURE CONCAVE SIDE IS DOWN ON
GASKET. FOR NIPPLE WASHERS THAT ARE
CAST, PLACE THE ROUGH SIDE AGAINST
THE GASKET.
section 2 INSTALLATION installation and maintenance manual form 170 page 4
INSTALLATION
2.0 INSTALLATION
Once you have decided on he correct location, use the following steps as a guideline for installing your GRIDCOOLER® Keel Cooler:
2.1 MAKING HOLES
2.1.1 Measure the distance between the Inlet & Outlet nozzles from center to center (also measure to the centers of the support studs when applicable) before cutting holes for them in the ship’s hull.
2.1.2 Make the holes through the hull 1/4 in. (6.4 mm) diameter oversized.
2.1.3 Make sure that the hull surfaces where the unit will be mounted are smooth and properly aligned (on steel hulls, if you burn the holes, grind the edges smooth afterwards).
This will allow the gaskets to seal properly and insure that no undue stress will be placed on the cooler.
2.2 FITTING UP
2.2.1 Under normal conditions, the compression of the mounting gaskets puts sufficient tension on the nozzle nuts (and support bolt nuts when applicable) to prevent them from working loose. To seal out water, apply a polysulfide rubber sealant like BoatLIFE Caulk or 3M Marine Sealant 101 around the gaskets, washers, and the points where the nozzles and support bolts penetrate the hull before assembly. Remember to tighten the nuts a second time, after the caulking has set.
NOTE: BoatLIFE is available from Life Industries (www.boatlife.com), call 800-382-9706 for a dealer near you. Marine Sealant 101 is available from 3M (www.3m.com), call 888-364-3577 for a dealer near you.
2.3 COPPER/NICKEL INSTALLATION
2.3.1 Mounting gaskets supplied with the GRIDCOOLER Keel
Cooler must be used to provide proper spacing between the unit and the ship’s hull. See Figure 10.
NOTE: EXTERIOR GASKETS: All “BN” & “CN” Series Models have 1/2 in. (12.7 mm) gaskets as standard. All legacy “B” & “C” Series Models have 1/4 in. (6.4 mm) gaskets standard. The “D” Series Models have 3/4 in. (19 mm) gaskets standard, however, 1/4 in. gaskets are available upon request.
NOZZLE NUT
NOZZLE (MACHINED) WASHER
(FINISHED FACE TOWARD NUT)
HOSE CONNECTOR
NOZZLE
HULL
BEAD OF SEALANT
DRAIN PLUG
NOZZLE GASKET
BEAD OF SEALANT
INSULATOR
(CUSTOMER PROVIDED PVC PIPE
CUT TO HULL THICKNESS)
HEADER GASKET
ZINC ELECTRODE
Maintenance Manual 7/10/12 10:11 AM Page 8 form 175 cary.klager Rectangle cary.klager Rectangle
COPPER/NICKEL UNIT
NUT TORQUES FT.-LBS. (KG-M)
NOZZLE THREAD SIZE
HEADER STUD SUPPORT BOLT
.75” 19mm
50 - 60 (7 - 8)
.625 - .75” 16 - 19mm
35 - 40 (5 - 5.5)
.5 - .75” 13 - 19mm
20 - 25 (3 - 3.5)
1” 25.4mm
50 - 60 (7 - 8)
1 - 1.5” 25 - 38mm
75 - 100 (10 - 14)
2” 51mm
125 - 150 (17 - 21)
2.5 - 3.5” 63 - 89mm
200 - 250 (28 - 35) section 2 INSTALLATION installation and maintenance manual form 170 page 5
INSTALLATION
2.3.2 To avoid over-tightening any of the supporting nuts, we recommend the following torques for all standard installations:
2.3.3 Zinc electrodes are standard equipment with most
copper/nickel units. They minimize the effects of galvanic corrosion, and should be replaced when deteriorated. The life of these plates varies with localities.
2.3.4 Attach the zinc electrodes using the special bolts and
washers supplied with the unit. They can be found in a cardboard box inside the unit shipping box.
See Figure 11.
FIG. 11 Zinc Attachment Detail
NOTE: Zinc replacement kits, including zinc electrodes, screws, and washers, can be ordered from the factory. Just give us the model number of your GRIDCOOLER® Keel Cooler.
2.4 ALUMINUM INSTALLATIONS
2.4.1 An aluminum GRIDCOOLER Keel Cooler should be
installed on unpainted aluminum hulls only.
2.4.2 The 1/4 inch mounting gaskets supplied with the unit must be used to provide proper spacing between the cooler and the ship’s hull.
2.4.3 To avoid over-tightening any of the supporting nuts, we recommend the following torques for all normal installations.
2.4.4 Most aluminum units have tapered threads on the nipples and no hose connectors (see installation drawing). These units can be piped directly to the engine, provided flexible couplings are used to remove engine vibration between the engine and the cooler.
2.4.5 If a wire reinforced rubber hose is used to connect the unit to the engine, put a screw-on coupling over the cooler nozzle threads.
2.4.6 Aluminum GRIDCOOLER Keel Coolers do not use
zinc electrodes.
2.5 PLUMBING
NOTE: Prior to installing cooler, flush entire piping system to remove any debris.
2.5.1 Remove the orange nozzle plugs from the GRIDCOOLER
unit before hooking up the plumbing to the cooler.
2.5.2 When converting an engine from inboard heat exchanger
cooling to keel cooling, do not pipe the keel cooler to a heat exchanger, bypass the heat exchanger and pipe the keel cooler directly to the engine. See Figure 12 (next page).
ALUMINUM UNIT
NUT TORQUES FT-LBS (KG-M)
NOZZLE THREAD SUPPORT BOLT
1” 25.4mm
75 - 100 (10 - 14)
1.5 - 3” 38 - 76mm
125 - 150 (17 - 21)
.625” 16mm
20 - 25 (3 - 3.5)
DRAIN PLUG
ELECTRODE BOSSES
ZINC
ELECTRODE
PLATE
ELECTRODE
WASHERS
ELECTRODE
SCREWS
ZINC
ELECTRODE
PLATE
ELECTRODE
WASHERS
ELECTRODE
SCREWS
ELECTRODE BOSSES
DRAIN PLUG
E1 OPTION
Maintenance Manual 7/10/12 10:11 AM Page 9 section 2 INSTALLATION installation and maintenance manual form 170 page 6
INSTALLATION
FIG. 12 Plumb keel cooler directly to the engine (simplified)
2.5.3 As a rule-of-thumb, the expansion tank for your cooling system should be able to hold approximately 10% of the total cooling system coolant. Contact your engine dealer for the exact size.
2.5.4 When piping, do not use tubing or fittings smaller than the engine or keel cooler connections. If those on the engine are larger than those on the keel cooler, reduce the piping at the keel cooler, not the engine. Use a minimum of elbows, and check all connections for leaks. All high areas in piping must be vented.
2.5.5 To avoid transmitting engine vibrations to the
GRIDCOOLER unit, use wire reinforced rubber hoses and clamps at the engine and keel cooler connections.
2.5.6 When installing a multiple-pass unit in a side mounted
position, the inlet line should be connected to the lower nozzle to force air up and out of the cooling system. Special units can be ordered with additional air bleeding vents in the stud end of the cooler.
2.5.7 To avoid air pockets that would restrict water flow through the cooling system and cause overheating, install the piping between the engine and the cooler so that it is self-venting.
NOTE: Depending on installation, special air bleeding vents are available as an option.
2.5.8 For piping diagrams for multiple cooler installations, see Figures 13 through 16.
FIG. 13 Coolers connected in parallel
FIG. 14 Multiple-pass coolers connected in parallel
FIG. 15 Coolers connected in series
FIG. 16 Coolers connected in series parallel
2.6 FILLING & TESTING
NOTE: Do not exceed 35 PSI (2.41 Bar) when pressure testing a GRIDCOOLER® Keel Cooler.
2.6.1 Always premix ethylene glycol (antifreeze) with water
before adding it to the cooling system. Contact your engine dealer for the proper antifreeze type and percentage for your engine. We do not recommend the use of propylene glycol in your cooling system.
2.6.2 Never mix ethylene and propolyene glycol based
antifreezes in your cooling system.
2.6.3 When installing a GRIDCOOLER Keel Cooler in a side
mounted position, it is important that the unit is completely filled with water before launching the vessel. This can be accomplished by using the following procedure:
1. At the outlet end of the unit, remove the upper drain plug and fill the unit with cooling water. See Figure 17
2. When water runs out of the upper drain, replace the plug.
3. The unit is now filled with water. If the system is ever drained, you must repeat this procedure.
NOTE: Do not exceed 35 PSI (2.41 Bar) when pressure testing a GRIDCOOLER® Keel Cooler.
FIG. 17 Remove upper drain plug to bleed air from the system.
Maintenance Manual 7/10/12 10:12 AM Page 10
FIG. 18 Compression Sealing Parts Placement section 3 SPECIAL INSTALLATIONS installation and maintenance manual form 170 page 7
SPECIAL INSTALLATIONS
3.0 SPECIAL INSTALLATIONS
3.1 COFFERDAM INSTALLATION WITH
COMPRESSION GASKETS(see Figure 18)
3.1.1 Place a continuous bead of sealant around the header
gasket that separates the GRIDCOOLER® unit from the outer hull. Customers have reported good success with polysulfide rubber sealants such as 3M Marine Sealant 101 or BoatLIFE Caulk.
NOTE: BoatLIFE is available from Life Industries (www.boatlife.com), call 800-382-9706 for a dealer near you. Marine Sealant 101 is available from 3M (www.3m.com), call 888-364-3577 for a dealer near you.
3.1.2 Hoist the unit up into the mounting position. The exterior header gasket must be in full contact with the hull.
3.1.3 Place a second continuous bead of sealant on the inner hull around the nipple. This bead must be in contact with the hull and the nipple.
3.1.4 Place the nipple gasket (harder of the two interior gaskets) down over the nozzle as far as possible.
3.1.5 Place the unfinished cast washer down over the nipple as far as possible. The side of the washer marked “up” must face away from the hull.
3.1.6 Place the compression gasket (softer of the two interior gaskets) down over the nipple as far as possible.
3.1.7 Place the semi finished washer down over the nipple, finished side away from the hull.
3.1.8 Run the nut down over the nipple and torque to spec. (See chart in Section 2.3.2)
3.1.9 Torque the nut to spec a second time after the sealant has set.
NOZZLE NUT
NOZZLE (MACHINED) WASHER
(FINISHED FACE TOWARD NUT)
HOSE CONNECTOR
NOZZLE
HULL
BEAD OF SEALANT
DRAIN PLUG
BEAD OF SEALANT
HEADER GASKET
ZINC ELECTRODE
COMPRESSION GASKET
(SOFT GASKET)
NOZZLE GASKET
(HARDER GASKET)
COMPRESSION (UNFINISHED) WASHER
(TAPERED SIDE UP)
INSULATOR
(CUSTOMER PROVIDED PVC PIPE
CUT TO HULL THICKNESS)
Maintenance Manual 7/10/12 10:12 AM Page 11
FLANGE NUT TORQUE SPECIFICATIONS
.625” diameter or large stud
35-40 Ft. Lbs. 20-25 Ft. Lbs.
.500” diameter stud
OPTION: For ease of installation and maintenance, pipe to the side of the cofferdams. (see Figure 19)
FIG. 19 Pipe to side of cofferdam
FIG. 20 Z OPTION mounting detail
3.2 Z OPTION™ INSTALLATIONS
3.2.1 The Z OPTION GRIDCOOLER Keel Cooler replaces the
typical through-hull nozzle mounting/connecting means with a copper-nickel flange, fused to the header. This flange utilizes a plurality of stainless steel mounting studs locked in place by setscrews to allow replacement in the event of damage.
3.2.2 The unit is also supplied with mating ASTM steel flanges and flange mounting hardware. The supplied hardware illustrated in Figure 20 includes nylon shoulder washers combined with neoprene gaskets to allow isolation from the vessel’s hull. Special extra heavy lock nuts and washers are provided for a secure installation.
3.2.3 Flange mounting hardware can be found in a cardboard box inside the unit shipping box.
3.2.4 The mating steel flange is welded to a pipe stub extending from the hull of the vessel. This pipe stub must be long enough to allow access to the flange lock nuts for tightening. Alignment of the flanges on the hull is critical.
We suggest that a template be made of the cooler to aid with the proper alignment of the flanges.
NOTE: Temporarily remove nylon shoulder washers while welding. Re-insert prior to mounting cooler
3.2.5 The torque specification for the flange nuts is as follows:
NOTE: Z OPTION units utilize our L OPTION™ support plates for intermediate mounting of the cooler.
See the next section for L OPTION mounting instructions.
GRIDCOOLER HEAD
STAINLESS SET SCREW
1/8” GASKET (THICK)
STEEL FLANGE
ENGINE PIPING
HULL
WASHER
SHOULDER WASHER
(NYLON)
STAINLESS LOCKNUT
section 3 SPECIAL INSTALLATIONS installation and maintenance manual form 170 page 8
SPECIAL INSTALLATIONS
Maintenance Manual 7/10/12 10:12 AM Page 12
FIG. 22 L OPTION support plate with angle welded to hull
FIG. 21 L OPTION support plate with stud welded to hull section 3 SPECIAL INSTALLATIONS installation and maintenance manual form 170 page 9
SPECIAL INSTALLATIONS
3.3 L OPTION™ SUPPORT PLATE INSTALLATION
The L OPTION support plates do not require a through-hull penetration. These support plates extend beyond the sides of the keel cooler allowing the customer the option to weld a mounting stud directly to the hull or to weld a short piece of angle to the hull as a securing means. The customer can then install the appropriate fasteners for the support plates.
Figures 21 and 22 show examples of this style of mounting.
The combination of the neoprene gasket and the nylon shoulder washer provide isolation of the cooler from the hull.
NEOPRENE GASKET
SHOULDER WASHER
(INSULATOR)
STAINLESS STEEL
WASHER
STAINLESS STEEL LOCK NUT
STAINLESS STEEL STUD
(WELD TO HULL)
“L” OPTION
SUPPORT PLATE
HULL
NEOPRENE GASKET
SHOULDER WASHER
(INSULATOR)
STAINLESS STEEL WASHER
STAINLESS STEEL LOCK NUT
STAINLESS STEEL BOLT
“L” OPTION
SUPPORT PLATE
HULL
STAINLESS STEEL WASHER
ANGLE
Maintenance Manual 7/10/12 10:12 AM Page 13 section 3 SPECIAL INSTALLATIONS installation and maintenance manual form 170 page 10
SPECIAL INSTALLATIONS
3.4 MOUNTING COPPER/NICKEL COOLERS
ON ALUMINUM HULLS
An electrical barrier must be placed between the GRIDCOOLER® unit and the hull. R. W. Fernstrum & Company does not formally approve any method of installing a copper/nickel GRIDCOOLER Keel Cooler on aluminum hulled vessels. However, the following technique has been used on hundreds of boats.
3.4.1 Sandblast the area of the hull where the unit will be
installed.
3.4.2 Coat the sandblasted area with a two-part fiberglass epoxy resin.
3.4.3 Spray the resin on in four separate coats. Don’t use any matting. Spray each coat just heavy enough so that it doesn’t start to run off.
3.4.4 After spraying on the fourth coat, and while the resin is still tacky, prime the entire area with the hull priming paint used on the rest of the vessel’s hull.
3.4.5 Apply the final bottom paint, and then install the cooler.
Maintenance Manual 7/10/12 10:12 AM Page 14
FIG. 23 Creating a bend in a cooler using a hydraulic press
FIG. 24 Creating a bend in a cooler using a hydraulic press
FIG. 25 Locate twisting hook as close as possible to the nozzle or stud
FIG. 26 Carefully apply downward force to impart a twist in the cooler section 4 FORMING GRIDCOOLER KEEL COOLER installation and maintenance manual form 170 page 11
FORMING GRIDCOOLER KEEL COOLER
4.0 FORMING THE GRIDCOOLER®
KEEL COOLER
4.1 BENDING A GRIDCOOLER KEEL COOLER
When bending a cooler in a press, support the cooler from underneath with wood blocking across the entire width of the unit. Blocking is also placed on top of the cooler, centrally located between the wood blocking underneath the cooler. The location of the wood blocking on the top of the cooler will determine the location of the bend. Since this method of bending exerts pressure on only a small area, the cooler will need to be repositioned multiple times to produce an even bend over the length of the cooler. Care must be taken to ensure that the unit is not bent too far at any one point. A tape measure or other measuring instrument, along with a template of the hull profile can be used to measure your progress. See Figures 23 and 24.
4.2 TWISTING A GRIDCOOLER KEEL COOLER
To produce a twist, first fabricate a hook onto the end of a short length of pipe using barstock. Hook this bar across the header as close to the nipple or stud as possible. The cooler may be secured in a press or placed on sawhorses with a person at each end. By placing your weight on the end of the pipe, you can produce a twist in the cooler. (See Figures 25 and 26).
NOTE: Do Not Bend greater than 1” over 12” of cooler length.
Do Not Twist beyond 1° over 12” of cooler length.
Maintenance Manual 7/10/12 10:12 AM Page 15 section 5 PERFORMANCE ISSUES installation and maintenance manual form 170 page 12
PERFORMANCE ISSUES
5.0 PERFORMANCE ISSUES
Determining the cause of overheating can be difficult. Here are some things to look for:
5.1 Wire Reinforced Rubber Hose:
Could the rubber hose part of the piping between the engine and the cooler be collapsed? This could cut the cooling water supply to the unit and reduce its efficiency.
Be sure you are using wire reinforced rubber hose.
5.2 Piping:
Is the piping between the engine and the cooler as large or larger than the engine and cooler connections? (See section 2.4.4 under plumbing.) The piping should also be self-venting and arranged so that a minimum number of elbows are used.
5.3 Jacketwater:
Is the jacketwater circulating through the cooler? It may be taking a path of least resistance through the bypass (if one exists).
5.4 Thermostat:
Could the thermostat be stuck or could the wrong thermostat be in use? If so, it could give you a faulty temperature.
5.5 Jacketwater Pump:
Is the jacketwater pump working properly? If not, it could reduce the cooling systems efficiency.
5.6 Air in the System:
Was the unit installed in a way to allow all the air in the system to escape? When a multiple-pass unit is mounted on the rake of the vessel, make sure that the nozzles are mounted in the up or high position. See sections 1.6.3, 2.4.6, 2.4.7, & 2.5.3 under Installation. See Figure 9
5.7 Foreign Matter:
Could anything have gotten into the cooler nozzles? Make sure that the orange plastic cap plugs covering the ends of the hose connectors were removed and that no foreign matter, such as a rag, was dropped into the cooler nozzles.
5.8 Expansion Tank:
Could the water level be too low in the expansion tank?
This can reduce the cooling system’s efficiency.
5.9 External Coating:
Is the cooler painted or covered with any other coating?
This will have an insulating effect and will greatly reduce the heat transfer rate of the unit. The standard recommendation is to not coat the keel cooler.
5.10 Water Aeration:
Could the water around the cooler be aerated in any way?
Aeration will reduce the heat transfer rate of the keel cooler.
5.11 Moored at Dock:
Is the engine temperature rising while the vessel is moored in dock? If the unit is installed near the propeller, engage the propeller to circulate water past the unit, after taking the proper safety precautions.
5.12 Placement:
Is an aftercooler circuit overheating? Make sure that the low temperature cooling circuit is mounted forward of or closer to the skeg or keel than the jacketwater coolers.
5.13 Mounting Gaskets:
Were the mounting gaskets put in place when the unit was installed? The mounting gaskets supplied with the cooler must be used to provide adequate spacing between the unit and the ship’s hull. This will allow water to flow freely over the cooler tubes.
5.14 Glycol:
How much glycol (antifreeze) is in the system? Perhaps the cooler was not sized for the use of glycol in the system.
NOTE: Always premix glycol with water before adding it to the cooling system.
NOTE: Never mix ethylene and propolyene glycol.
5.15 Crushed Tubes:
Have the rectangular tubes on the cooler been crushed or pinched? This could restrict the internal water flow.
5.16 Blown Tubes:
Could the rectangular tubes on the unit have been blown or bulged by unusually high pressures? If so, the exterior water flow past the unit tubes could be impaired, retarding heat transfer.
5.17 Marine Growth:
Has your vessel been in dock for several months? You may find marine growth on the unit which will hinder the unit’s heat transfer rate. See Maintenance Section.
5.18 Oil Deposits:
Have you had engine problems? Oil may have gotten into the cooling water system and collected in the cooler, coating it with an oil film. See Maintenance Section.
5.19 Mineral Deposits:
Could you be using hard water in the system? Mineral Deposits can collect on the tube in the cooler, lining the inside with lime, calcium, etc. See Maintenance Section.
Maintenance Manual 7/10/12 10:12 AM Page 16 section 6 MAINTENANCE installation and maintenance manual form 170 page 13
MAINTENANCE
6.0 MAINTENANCE
A GRIDCOOLER® Keel Cooler that is clean inside and out will dissipate heat most efficiently. To keep your unit clean, a periodic check of the cooling system is recommended.
What follows are some ways to clean your GRIDCOOLER unit.
6.1 EXTERIOR
If the GRIDCOOLER Keel Cooler is used regularly, the 90/10 copper/nickel alloy in conjunction with the unit’s operating temperature will tend to keep the exterior of the unit relatively free of marine growth. However, if the unit is not in operation for extended periods of time, marine growth may result. Below are some ways of removing marine growth, paint, etc. from the exterior of the GRIDCOOLER unit:
6.1.1 Scrape:
Scraping is an effective way of removing larger matter from a cooler. The use of a rectangular instrument works best.
6.1.2 High Pressure Water Blast:
This cleaning method is effective in cleaning many things off of a cooler (paint is a notable exception).
6.1.3 Sandblast:
Sandblasting is also very effective, but very fine sand such as 40 to 60 grit blasting media at a maximum blast pressure of 90 psi (6.21 BAR) should be used.
6.1.4 Painting:
Coolers do not require painting. Doing so will decrease the units efficiency.
6.1.5 Zinc Electrodes:
Zinc electrodes are standard equipment with most copper/nickel units. They minimize the effects of galvanic corrosion, and should be replaced when deteriorated. The life of these electrodes varies with localities.
Zinc replacement kits, including zinc electrodes, screws, and washers, can be ordered from the factory. Just give us the model number of your GRIDCOOLER Keel Cooler.
NOTE: Zinc electrodes installed on coolers provide immediate protection to the cooler only. When using protective systems, the cooler should be taken into consideration during the hull survey.
NOTE: Zinc electrodes installed on coolers provide immediate protection to the cooler only. When using protective systems, the cooler should be taken into consideration during the hull survey.
NOTE: Never sandblast an ALUMINUM GRIDCOOLER unit.
6.2 INTERIOR
The interior of your GRIDCOOLER unit may need periodic cleaning to remove oil, old glycol, mineral deposits, etc. The easiest and most convenient way of doing this is the use of a radiator flush. Contact your engine dealer for the proper radiator flush type for your engine.
6.3 PRESSURE TESTING
Do not exceed 35 PSI (2.41 Bar) when pressure testing a GRIDCOOLER® Keel Cooler.
Maintenance Manual 7/10/12 10:12 AM Page 17 section 7 REPAIR installation and maintenance manual form 170 page 14
REPAIR
7.0 REPAIR
For a unit in warranty, attempt no repairs without first contacting the manufacturer, otherwise your warranty will be void.
For a unit out of warranty, if the unit is accidentally damaged while in use, you can make minor shipyard repairs as follows:
7.1 STRAIGHTENING
If the tubes are accidentally bent, they can be straightened with a hard wood block and a mallet. See Figure 27.
FIG. 27 Straightening tubes with a wooden block & mallet
7.2 COPPER/NICKEL GRIDCOOLER®
KEEL COOLER REPAIRS
7.2.1 Brazing:
Drain the cooler before brazing. Clean the area or joint to be brazed thoroughly with a good degreasing solvent followed by wire brushing. The braze wire should be 56% silver. Use 3/32 in. (2.24 mm) diameter braze 560 wire, with low temperature brazing flux. See Figure 28.
FIG. 28 Brazing repair
7.3 ALUMINUM GRIDCOOLER KEEL COOLER
REPAIRS
7.3.1 Tig Weld:
Drain the cooler before welding. Clean the area or joint to be welded thoroughly with a good degreasing solvent followed by stainless steel wire brushing. The aluminum filler rod used in the GRIDCOOLER Keel Cooler is R 5554 series aluminum, 3/32 in. (2.24 mm) diameter wire.
7.4 TEMPORARY REPAIR
For temporary repairs, liberally apply an epoxy compound similar to Devcon UW (Part Number: 11800) under water and Interguard 822 for above water repairs.
Before applying the epoxy compound, clean the surface of the GRIDCOOLER unit and relieve any internal pressure.
NOTE: Devcon UW is available from the Devcon Corporation (www.devcon.com), call (978) 777-1100 for a dealer near you. Interguard 822 is available from the International Paint Company (www.international-marine.com), call (800) 525-6824 for a dealer near you.
For major repairs not covered by our Limited Warranty, contact us by Phone (906) 863-5553 or Fax (906) 863-5634. Give us a complete description of the damage, and we’ll tell you if and how your unit can be repaired.
7.5 COUPLINGS REPAIRS
A damaged section of tube can be replaced with two couplings and a replacement length of tube.
FIG. 29 Replacing a section of tube
A single coupling can be split on one narrow end, slid over the tube, and brazed into place to patch a hole in a tube.
FIG. 30 Patching a hole in a tube
DAMAGED SECTION
OF TUBE TUBE
COUPLING
COUPLING
COUPLING
COUPLING
NEW SECTION
OF TUBE
NEW SECTION
OF TUBE
HOLE IN TUBE
SPLIT COUPLING
Maintenance Manual 7/10/12 10:12 AM Page 18 section 8 STRAY-CURRENT CORROSION installation and maintenance manual form 170 page 15
STRAY-CURRENT CORROSION
8.0 STRAY-CURRENT CORROSION
Since Fernstrum’s involvement in the design of any particular marine vessel is limited to the heat transfer requirements of the vessel, grounding or bonding of the keel cooler is best left to the person responsible for the design of the corrosion protection system. If the customer needs guidance on this issue it’s suggested to isolate the cooler from the hull and monitor closely the condition of the cooler, zincs and surrounding hull area for the first few months. This is for the simple fact that it is easier to ground a cooler after installation than it is to isolate it.
If an impressed current system is used, it is best to consult the manufacturer of the system for their recommendations as to grounding and bonding of equipment mounted to the hull.
Most corrosion experts feel that isolating the keel cooler from the steel hull is the best practice (with cathodic protection in particular). As for bonding the unit, there is sometimes a difference of opinion. In an ideal situation (i.e.
no sources of stray current, no defects in the electrical system either onboard or at dockside), experts will typically recommend bonding the unit. However, in an imperfect world it’s found that in some cases the opposite is the best.
Ultimately the best plan of action is to have a corrosion engineer evaluate the corrosion protection scheme of the vessel and verify its proper function.
As for the issue of the product warranty, it is not affected by how the keel cooler is configured into the corrosion protection system, as it covers defects in material and workmanship, not failure due to galvanic or stray current corrosion.
Maintenance Manual 7/10/12 10:12 AM Page 19
9.0 REPLACEMENT PARTS
section 9 PARTS installation and maintenance manual form 170 page 16
PARTS
DRAIN PLUG
SUPPORT BOLT NUT
SUPPORT BOLT NUT
NOZZLE NUT
NOZZLE WASHER
GASKETS
SUPPORT BOLT WASHER
GASKETS
SUPPORT BOLT WASHER
DRAIN PLUG
SUPPORT BOLT NUT
NOZZLE NUT
NOZZLE WASHER
GASKETS
SUPPORT BOLT WASHER
FIG. 31 Single Pass Gridcooler Keel Cooler
FIG. 32 Multi Pass Gridcooler Keel Cooler
ZINC SET
(EACH END)
ZINC SET
(EACH END)
Maintenance Manual 7/10/12 10:12 AM Page 20 section 9 PARTS installation and maintenance manual form 170 page 17
PARTS
NOTE: All gaskets are sold in a complete set. Sets include all internal gaskets, exterior gaskets and isolators.
NOTE: Zincs are sold in sets consisting of two (2) zinc anodes, four (4) mounting bolts and four (4) washers. One (1) Keel Cooler requires one (1) set.
Keel Cooler model number is needed to identify correct set.
DRAIN PLUG
NOTE: Visit website for standard Keel Cooler replacement parts listed. www.fernstrum.com For specials call factory direct.
FIG. 33 Z-Option Single Pass Gridcooler Keel Cooler
FIG. 34 Z-OPTION MULTI PASS GRIDCOOLER KEEL COOLER
SET SCREW
FLANGE GASKET
FLANGE
INSULATOR
(NYLON)
FLANGE STUD BOLT
LOCKNUT
WASHER
GASKET
SUPPORT PLATE
INSULATOR
(NYLON)
STEEL FLANGE
DRAIN PLUG
SUPPORT PLATE
INSULATOR
(NYLON)
GASKETS
FLANGE GASKET
FLANGE
INSULATOR
(NYLON)
FLANGE STUD BOLT
LOCKNUT
WASHER
SET SCREW
STEEL FLANGE
ZINC SET
(EACH END)
ZINC SET
(EACH END)
Maintenance Manual 7/10/12 10:12 AM Page 21 section 10 WARRANTY installation and maintenance manual form 170 page 18
WARRANTY
10.0 LIMITED WARRANTY
The R.W. Fernstrum & Company, manufacturer, carefully tests and inspects each GRIDCOOLER® Keel Cooler before it leaves the point of manufacture. The manufacturer makes no representations or warranties, express or implied, statutory or otherwise, except those herein expressly contained and shall not be held liable on any account except for repair or replacement under the terms following.
The manufacturer will, as to each GRIDCOOLER Keel Cooler unit registered with it by the purchaser, repair or replace free of charge, such Keel Cooler unit as is found upon manufacturer’s inspection to be defective because of material or workmanship providing the same had been returned to the manufacturer’s factory, or a more convenient point as designated by the manufacturer, transportation prepaid, and received by the manufacturer within ninety (90) days from the date of delivery, with respect to the aluminum GRIDCOOLER Keel Cooler, and within two (2) years with respect to the copper/nickel GRIDCOOLER Keel Cooler. The manufacturer’s obligation hereunder shall be limited to such time period and to the direct cost of replacement and shall not include labor transportation, haul-out, launch, towing or storage charges, mechanic travel time, inconvenience, loss of time or income, removal and replacement and/or modification of any boat parts to facilitate repairs or other such expenses incurred by purchaser.
This limited warranty shall not be effective with respect to GRIDCOOLER Keel Cooler to which repairs or alterations have been made unless authorized or performed by the manufacturer, nor to defects arising because of improper installation, misuse, accident or other causes beyond the control of the manufacturer.
Should any disputes arise with regard to their respective rights, duties and responsibilities under the Limited Warranty, all such disputes shall be governed by the laws of the State of Michigan to the extent that the same do not conflict with the laws of the United States and any litigation growing out of any such dispute shall be commenced in Circuit Court for Menominee County, in the State of Michigan, U.S.A
PLEASE KEEP THIS FORM ON THE VESSEL FITTED WITH THE GRIDCOOLER UNITS.
THE INFORMATION BELOW WILL BE OF USE FOR FUTURE REFERENCE.
ENGINE INFORMATION GRIDCOOLER INFORMATION
MAKE OF ENGINE MODEL OF ENGINE
HP/RPM
(KW/RPM) QUANTITYMODEL OF GRIDCOOLER
Maintenance Manual 7/10/12 10:12 AM Page 22 section 11 RECOMMENDATION FORM installation and maintenance manual form 170 page 19
RECOMMENDATION FORM
ENGINE INFO
TYPE Propulsion � Bowthruster � Generator � Other
MANIFOLD Wet � Dry � Make
Model
HP & RPM
Heat Rejection
Fresh Water Flow Rate
Fresh Water Temp into Cooler
Fresh Water Temp Out or Drop Across Cooler
Minimum Hull Speed at Full Rated Power under full load) (If Speed is 0 knots, or the engine is used as a generator size for 1/2 mph)
Maximum Sea Water Temp Engine Age % Antifreeze Used
Make & Model of Gear
Type of Boat (ferry, trawler, pleasure boat, etc.)
Hull Construction Steel � Fiberglass � Wood � Aluminum � Comments
CUSTOMER
PHONE
FAX
Date
Initials
� Drop � Out
� Painted � Unpainted
Maintenance Manual 7/10/12 10:12 AM Page 23 fernstrum.com Phone: 906.863.5553 • Fax: 906.863.5203 • Email: sales@fernstrum.com