Attachment L - Radon Report.pdf

PDF 6 MB Posted

Attached to
Recapitalize Family Housing, Station Portage, U. S. Coast Guard Station Portage, Dollar Bay, MI
Solicitation number
70Z04725RPCNI0002
Issued by

About this file

This document is a Radon Sampling Report for a U.S. Coast Guard project in Dollar Bay, Michigan. The report was prepared by TriMedia Environmental & Engineering Services, LLC and summarizes the results of radon testing conducted at several housing units on October 24, 2023. Radon levels were measured in picoCuries per liter (pCi/L), with the EPA action level being 4.0 pCi/L. The testing found no radon levels above 4.0 pCi/L, so no further action is required at this time. The report includes details on the sampling methodology, test locations, results, and photographic documentation.

The related federal contract opportunity is for the Recapitalization of Family Housing at the U.S. Coast Guard Station in Portage, Michigan. This design-build project will construct five new multiplex housing units, consisting of two three-bedroom and three four-bedroom units. The contract also includes three optional items for additional housing and a maintenance building. This opportunity is limited to DHS, NMACC III, Pool II contract holders.

View the file

Other files

File Type Posted
70Z04725RPCNI0002 _Amendment 0007.pdf PDF
70Z04725RPCNI0002_Amendment 0006.pdf PDF
70Z04725RPCNI0002_Amendment 0005.pdf PDF
70Z04725RPCNI0002 _Amendment 0004.pdf PDF
Portage Housing Site Visit_Sign In.pdf PDF
70Z04725RPCNI0002_Amendment 0003.pdf PDF
70Z04725RPCNI0002_Amendment 0002.pdf PDF
70Z04725RPCNI0002_Amendment 0001.pdf PDF
Attachment C - 92120 Multi-Mission Station -1997.pdf PDF
TO Announcement_70Z04725RPCNI0002.pdf PDF
Drawing Format and Handling Job Guide (JG 36-51 73 15-02).pdf PDF
Attachment D - Portage Housing NEPA CATEX.pdf PDF
Attachment M - X3888 Construct Six Housing Units.zip ZIP file
Attachment G - CSTO Family Housing Design.pdf PDF
Attachment E - FDCC ENVIRONMENTAL COMPLIANCE INSPECTION (July 2022).pdf PDF
Appendix D- LEED for HOMES.pdf PDF
Drawing Stds and Management (CSTO 36-51 73 15-01).pdf PDF
DBA_Building_Houghton County.pdf PDF
Appendix A_Exterior Wall Detail.pdf PDF
Attachment A - Geotechnical Report_05JAN24.pdf PDF
Attachment K - USCG Station Portage Environmental Report.pdf PDF
Attachment J - Fire Flow Report Osceola Twp.pdf PDF
Attachment I - USCG Station Portage Survey.pdf PDF
Attachment B - STA_Portage_Crawl_Space_Repairs-2008.pdf PDF
Attachment F - 09-6774947 Recap Family Housing PMDS V7.xlsx XLSX spreadsheet
Appendices_Attach_CAD Files.zip ZIP file
Appendix B_ Roof Design.pdf PDF
6774947_Final_Housing ReCap_StaPortage_MI_updated_11-12-24.pdf PDF
Appendix C_BSD-135_Ice Dams.pdf PDF
Attachment H - CSTO New Building Design and Construction.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

830 W. Washington Street

Marquette, MI 49855 906.228.5125

906.228.5126 Fax

www.trimediaee.com

Update: November 17, 2023 Initial: November 9, 2023

Sent Via Electronic Mail Mr. Elliot Rouleau, MSc, PE, Lead Geotechnical Consultant

WSP

809 Delta Avenue Gladstone, Michigan 49837

Re: Radon Sampling Results – for the U.S. Coast Guard Project in Dollar Bay, Michigan

TriMedia Project Number 2023-3130

Dear Mr. Rouleau:

TriMedia Environmental & Engineering Services, LLC (TriMedia) was retained by the U.S. Coast Guard to provide Radon sampling at the identified housing locations in Dollar Bay, Michigan.

SAMPLING ACTIVITIES

TriMedia was on site to establish radon sampling locations and to collect samples on October 24, 2023. Each housing complex was sampled during the same time period. Radon sampling requires sampling be performed on the lowest possible level of the structure being tested. All housing units are slab on grade construction so the lowest level of sampling available was the main floor with two locations selected for each unit. The radon test was performed using a liquid scintillation radon detector and counted on a liquid scintillation counter using approved EPA testing protocols for Radon in Air. Closed building conditions for short‐term testing required all windows and doors be closed with only momentary entry and exit allowed. Heating and cooling systems were set to occupied temperatures and settings, and no equipment for exchange of indoor and outdoor air was allowed, except what is a permanent condition of the heating or cooling system. There was no severe or unusual weather during the test period with exterior temperatures being between 40 and 50 degrees Fahrenheit during the day and 30 to 40 degrees Fahrenheit during the night with no precipitation.

Two samples were collected at each residence. Radon testing was conducted for 48 hours with the testing devices left undisturbed. Temperature and humidity were recorded on the Radon Data Sheet provided with the EMSL Analytical Inc. (EMSL) Sample Kit. Both test vials were labeled with a unique sample number, appropriately containerized, and shipped via overnight carrier under chain-of-custody documentation to EMSL in Cinnaminson, New Jersey. Lab reports are enclosed for your records.

SUMMARY OF FINDINGS AND RECOMMENDATIONS

Radon is measured in picoCuries per liter of air (pCi/L). The US EPA action level for radon is 4.0 pCi/L with a recommendation that measured levels above 4.0 pCi/L be corrected. Below in the tables are the sample locations and results. No exceedances were detected, therefore no further action with regards to radon is necessary at this time.

Mr. Elliot Rouleau

WSP

Location Device # Radon Activity pCi/L

Average Radon Activity pCi/L

Start Time 10/24/2023

Stop Time 10/27/2023

Temperature F

Humidity

Building 22900

547158 0.4

0.35

10:17 AM 9:18 AM 70 50

Building 22900

547147 0.3 10:18 AM 9:19 AM 70 50

Building 22910

547460 0.1

0.15

10:11 AM 9:16 AM 70 45

Building 22910

547283 0.2 10:12 AM 9:16 AM 70 45

Building 22920

547407 0.4

0.25

10:06 AM 9:15 AM 70 50

Building 22920

547181 -0.1** 10:07 AM 9:15 AM 70 50

Building 22950*

547189 0.2

0.35

9:39 AM 9:05 AM 55 30

Building 22950*

547240 0.5 9:40 AM 9:05 AM 55 30

Building 22960

547153 0.1

0.10

9:59 AM 9:08 AM 70 40

Building 22960

547358 -0.1** 10:01 AM 9:08: AM 70 50

Building 22970

547335 0.8

0.65

9:52 AM 9:10 AM 70 40

Building 22970

547349 0.5 9:55 AM 9:10 AM 70 50

*Unoccupied Residence

**The negative number in Radon in air analysis occurs from background subtraction. The background counts per minute are subtracted from the samples counts per minute so when the background is higher than the sample this produces the negative number. The results are reported as measured, including zeros and negative numbers. This essentially can be interpreted as a non-detect result.

It is hoped this Summary Report meets your needs and expectations. Should you have any questions regarding this correspondence, please do not hesitate to contact the undersigned at

(906) 228-5125 or via email at cbrochu@trimediaee.com. On behalf of the professional staff at TriMedia, thank you for the opportunity to be of service to WSP.

Sincerely, TriMedia Environmental & Engineering Services, LLC

Corey Brochu, MS, CIH, Andrew Tripp, MPH IH/Safety Department Manager Project Industrial Hygienist

AMT/jet/cjb

Enclosure(s): Photo Log Building Layout - Sampling Locations Radon Lab Results cc: TriMedia File 2023-3130

U.S. COAST GUARD

DOLLAR BAY, MICHIGAN

Photo Log Page 1 of 3 Radon Sampling TriMedia Project # 2023-3130

Description: 22900 - Exterior

Date: October 24, 2023 Taken By: AMT

Description: 22900 – Family Room 547147

Description: 22900 Living Room 547158

Description: 22910 Exterior

Description: 22910 Family Room 547283

Description: 22910 Living Room 547560

Photo Log Page 2 of 3

Description: 22920 Exterior

Description: 22920 Family Room 547181

Date: October 24, 2023 Taken By:

AMT

Description: Living room 547407

Description: 22950 Exterior Vacant

Description: 22950 Family Room

Description: 22950 Living Room 547189

Photo Log Page 3 of 3

Description: 22960 Family Room 547358

Description: 22960 Living Room 547153

Description: 22970 Exterior

Description: 22970 Computer Room 547349

Description: 22970 Living Room 547335

X= SAMPLE LOCATIONSBuilding 22900

X

Building 22910

X = TEST KIT LOCATIONS

Building 22920

Building 22950

Building 22960

Building 22970 X= SAMPLE LOCATIONS

2023 - 3130 WSP Dollar Bay

EMSL Analytical, Inc.

200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (800) 220-3675 / (856) 786-0327 http://www.EMSL.com cinnaminsonradonlab@emsl.com

382306619 CustomerID: TRIC50 CustomerPO:

ProjectID:

EMSL Order:

Attn: Corey Brochu TriMedia Environmental & Engineering Svs 830 W. Washington St Marquette, MI 49855

Received: 10/31/2023 11:09 AM

2023 - 3130 WSP Dollar Bay

Fax: (906) 228-5126 Phone: (906) 228-5125

Project:

11/1/2023Analysis Date:

10/24/2023Collected:

Test Report: Radon in Air Test Results

Liquid Scintillation ID Location

Samples for EMSL Kit 306910 Humidity

Temperature

F Radon Activity pCi/L Sample TypeStart Stop

547158 382306619-0001

Bldg 22900 - LV Customer0.4 10/24/2023

10:17:00 AM

10/27/2023

9:18:00 AM

70 50

Sample Notes:

Liquid Scintillation ID Location

Samples for EMSL Kit 306909 Humidity

Temperature

F Radon Activity pCi/L Sample TypeStart Stop

547147 382306619-0002

Bldg 22900 - LV Customer0.3 10/24/2023

10:18:00 AM

10/27/2023

9:19:00 AM

70 50

Sample Notes:

Liquid Scintillation ID Location

Samples for EMSL Kit 306916 Humidity

Temperature

F Radon Activity pCi/L Sample TypeStart Stop

547181 382306619-0004

Bldg 22920 - LV Customer-0.1 10/24/2023

10:07:00 AM

10/27/2023

9:15:00 AM

70 50

Sample Notes:

Liquid Scintillation ID Location

Samples for EMSL Kit 306907 Humidity

Temperature

F Radon Activity pCi/L Sample TypeStart Stop

547189 382306619-0005

Bldg 22950 - LV Customer0.2 10/24/2023

9:39:00 AM

10/27/2023

9:05:00 AM

55 30

Sample Notes:

Liquid Scintillation ID Location

Samples for EMSL Kit 306911 Humidity

Temperature

F Radon Activity pCi/L Sample TypeStart Stop

547460 382306619-0007

Bldg 22910 - LV Customer0.1 10/24/2023

10:11:00 AM

10/27/2023

9:16:00 AM

70 45

Sample Notes:

Page 1 of 4Test Report RadonMultiKit-7.30.4 Printed: 11/9/2023 12:23:06 PM http://www.EMSL.com mailto:cinnaminsonradonlab@emsl.com

200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (800) 220-3675 / (856) 786-0327 http://www.EMSL.com cinnaminsonradonlab@emsl.com

382306619 CustomerID: TRIC50 CustomerPO:

ProjectID:

EMSL Order:

Attn: Corey Brochu TriMedia Environmental & Engineering Svs 830 W. Washington St Marquette, MI 49855

Received: 10/31/2023 11:09 AM

2023 - 3130 WSP Dollar Bay

Fax: (906) 228-5126 Phone: (906) 228-5125

Project:

11/1/2023Analysis Date:

10/24/2023Collected:

Test Report: Radon in Air Test Results

Liquid Scintillation ID Location

Samples for EMSL Kit 306914 Humidity

Temperature

F Radon Activity pCi/L Sample TypeStart Stop

547335 382306619-0009

Bldg 22970 - LV Customer0.8 10/24/2023

9:52:00 AM

10/27/2023

9:10:00 AM

70 50

Sample Notes:

Liquid Scintillation ID Location

Samples for EMSL Kit 306913 Humidity

Temperature

F Radon Activity pCi/L Sample TypeStart Stop

547349 382306619-0010

Bldg 22970 - CM Customer0.5 10/24/2023

9:55:00 AM

10/27/2023

9:10:00 AM

70 50

Sample Notes:

Liquid Scintillation ID Location

Samples for EMSL Kit 306906 Humidity

Temperature

F Radon Activity pCi/L Sample TypeStart Stop

547153 382306619-0011

Bldg 22960 - LV Customer0.1 10/24/2023

9:59:00 AM

10/27/2023

9:08:00 AM

70 40

Sample Notes:

Liquid Scintillation ID Location

Samples for EMSL Kit 306915 Humidity

Temperature

F Radon Activity pCi/L Sample TypeStart Stop

547407 382306619-0003

Bldg 22900 - LV Customer0.4 10/24/2023

10:06:00 AM

10/27/2023

9:15:00 AM

70 50

Sample Notes:

547601

382306619-0013

Bldg 22900 - LV Blank-0.1 10/24/2023

10:06:00 AM

10/27/2023

9:15:00 AM

70 50

Sample Notes:

Page 2 of 4Test Report RadonMultiKit-7.30.4 Printed: 11/9/2023 12:23:06 PM

200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (800) 220-3675 / (856) 786-0327 http://www.EMSL.com cinnaminsonradonlab@emsl.com

382306619 CustomerID: TRIC50 CustomerPO:

ProjectID:

EMSL Order:

Attn: Corey Brochu TriMedia Environmental & Engineering Svs 830 W. Washington St Marquette, MI 49855

Received: 10/31/2023 11:09 AM

2023 - 3130 WSP Dollar Bay

Fax: (906) 228-5126 Phone: (906) 228-5125

Project:

11/1/2023Analysis Date:

10/24/2023Collected:

Test Report: Radon in Air Test Results

Liquid Scintillation ID Location

Samples for EMSL Kit 306908 Humidity

Temperature

F Radon Activity pCi/L Sample TypeStart Stop

547240 382306619-0006

Bldg 22950 - FR Customer0.5 10/24/2023

9:40:00 AM

10/27/2023

9:05:00 AM

55 30

Sample Notes:

546352

382306619-0014

Bldg 22950 - FR Duplicate0.4 10/24/2023

9:40:00 AM

10/27/2023

9:05:00 AM

55 30

Sample Notes:

Duplicate RPD = 22.2%

Liquid Scintillation ID Location

Samples for EMSL Kit 306912 Humidity

Temperature

F Radon Activity pCi/L Sample TypeStart Stop

547283 382306619-0008

Bldg 22910 - LV Customer0.2 10/24/2023

10:12:00 AM

10/27/2023

9:16:00 AM

70 45

Sample Notes:

546384

382306619-0015

Bldg 22910 - LV Duplicate0.4 10/24/2023

10:12:00 AM

10/27/2023

9:16:00 AM

70 45

Sample Notes:

Duplicate RPD = 66.7%

Liquid Scintillation ID Location

Samples for EMSL Kit 306905 Humidity

Temperature

F Radon Activity pCi/L Sample TypeStart Stop

547358 382306619-0012

Bldg 22960 Customer-0.1 10/24/2023

10:01:00 AM

10/27/2023

9:08:00 AM

70 40

Sample Notes:

547523

382306619-0016

Bldg 22960 Blank-0.5 10/24/2023

10:01:00 AM

10/27/2023

9:08:00 AM

70 40

Sample Notes:

Report Note

The radon test was performed using a liquid scintillation radon detector/s and counted on a liquid scintillation counter using approved EPA testing protocols for Radon in Air testing. The EPA recommends fixing your home if the average of two short-term tests taken in the lowest lived-in level of the home show radon levels that are equal to or greater than 4.0pCi/L.

The EPA recommends retesting your home every two years.

Please contact EMSL Analytical, Inc. or your State Health Department for further information.

All procedures used for generating this report are in complete accordance with the current EPA protocols for the analysis of Radon in Air.

Page 3 of 4Test Report RadonMultiKit-7.30.4 Printed: 11/9/2023 12:23:06 PM

200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (800) 220-3675 / (856) 786-0327 http://www.EMSL.com cinnaminsonradonlab@emsl.com

382306619 CustomerID: TRIC50 CustomerPO:

ProjectID:

EMSL Order:

Attn: Corey Brochu TriMedia Environmental & Engineering Svs 830 W. Washington St Marquette, MI 49855

Received: 10/31/2023 11:09 AM

2023 - 3130 WSP Dollar Bay

Fax: (906) 228-5126 Phone: (906) 228-5125

Project:

11/1/2023Analysis Date:

10/24/2023Collected:

Test Report: Radon in Air Test Results

Dominic Gehret, Radiochemistry Laboratory Manager, NJ Radon Measurement Specialist MES 13910 or other approved signatory

Analyst(s)

Please visit www.radontestinglab.com

In no event shall EMSL be liable for indirect, special, consequential, or incidental damages, including, but not limited to, damages for loss of profit or goodwill regardless of the negligence (either sole or concurrent) of EMSL and whether EMSL has been informed of the possibility of such damages, arising out of or in connection with EMSL’s services thereunder or the delivery, use, reliance upon or interpretation of test results by client or any third party. We accept no legal responsibility for the purposes for which the client uses the test results. In no event shall EMSL be liable to a client or any third party, whether based upon theories of tort, contract or any other legal or equitable theory, in excess of the amount paid to EMSL by client thereunder. The test results meets all NELAC requirements unless otherwise specified.

Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ FL RB2034/R2687,IL RNL2008202,IN RTL00935,IA RNLAB10005,KS KS-LB-0005/KS-MS-0482,ME SPC202,MN RL- 0005,NE 474/RMB-1083,NJ 03036/MEB92525/MES13910,NY 10872,OH RL39,OK D9952,PA 2573/3393/68-00367,RI RMB-108/RI00179,WV RL000220,NRSB-ARL6006,NRPP

Jeanel Zoll (16)

Initial report from 11/06/2023 14:48:56

Page 4 of 4Test Report RadonMultiKit-7.30.4 Printed: 11/9/2023 12:23:06 PM http://www.EMSL.com http://www.radontestinglab.com

Photo Log 2023-3130.pdf
Layout Sample Locations.pdf
22900 - Layout
22910 - Layout
22920 - Layout
22950 - Layout
22960 - Layout
22970 - Layout

File details come from the government source that posted it. Updated .