Attachment K - BOF HEC Original Douments FFE Binder 29 October 2021.pdf

PDF 25 MB Posted

Attached to
SOF BATTALION OPERATIONS FACILITY, HEC, ALEXANDRIA, VIRGINIA Federal contract opportunity
Solicitation number
W912DR22R0030
Issued by
Department of the Army Corps of Engineers Engineering District Baltimore

About this file

This document provides details for a federal construction solicitation. The U.S. Army Corps of Engineers, Baltimore District is seeking a firm-fixed-price construction contract utilizing a best value tradeoff process for the SOF Battalion Operations Facility at the HEC in Alexandria, Virginia. Interested parties should review the attached solicitation and attachments for full requirement details, including the scope of work to construct the proposed facility. The solicitation number is W912DR22R0030 and responses are due based on the dates outlined in the attached documents.

View the file

Other files for this federal contract opportunity

Other files attached to SOF BATTALION OPERATIONS FACILITY, HEC, ALEXANDRIA, VIRGINIA, newest first.
File Type Posted
Amendment 0002 Files.zip ZIP file
B.08.03 RFI Responses.pdf PDF
B.08.03 Amendment W912DR22R0030 0002.pdf PDF
I.01.11 BOF1 Site Visit Attendance Roster - 25MAY22.pdf PDF
B.08.03 Amendment W912DR22R0030 0001.pdf PDF
Attachment L - Site Visit Visitor Authorization Form for HECSA.xlsx XLSX spreadsheet
Attachment H.1 - BOF HEC Original Documents Drawings Vol 1 29 October 2021.pdf PDF
Attachment C - SBPP Proposal Format.pdf PDF
Attachment B - Past Performance Questionnaire.pdf PDF
Attachment H.2 - BOF HEC Original Documents Drawings Vol 1 29 October 2021.pdf PDF
Attachment G - Vol_4_BOF HEC Original Documents Submittal Specifications 29 October 2021.pdf PDF
B.08.02 Solicitation_W912DR22R0030.pdf PDF
Attachment A - Experience in Relevant Projects.pdf PDF
Attachment J - BOF HEC Original Documents SID Binder 29 October 2021.pdf PDF
Attachment F - Vol_3_BOF HEC Original Documents Submittal Specifications 29 October 2021.pdf PDF
Attachment I - H.08.04_BOF HEC Original Documents Drawings Vol 2 29 October 2021.pdf PDF
Attachment E - Vol_2_BOF HEC Original Documents Submittal Specifications 29 October 2021.pdf PDF
Attachment D - Vol_1_BOF HEC Original Documents Submittal Specifications 29 October 2021.pdf PDF
Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STANTEC PROJECT NUMBER: 178451908

CONSTRUCTION CONTRACT NO.: W912HN19D2000/ DO W912DR20F0205

Date: 29 October 2021

US Army Corps of Engineers

Baltimore District

ARCHITECT/DESIGN:

Stantec Architecture Inc.

4798 New Broad Street, Suite 100

Orlando, Florida 32814

FINAL SUBMITTAL

FURNITURE, FIXTURE & EQUIPMENT (FF&E)

BATTALION OPERATIONS FACILITY PN91018 / P2 477925

Humphries Engineering Center Alexandria, VA

BINDER PREPARED BY:

Lori Carson, NCIDQ

Stantec Architecture, Inc.

4798 New Broad Street, Suite 100

Orlando, Florida 32814

P: 407.425.2500

STANTEC PROJECT NUMBER: 178451908

CONSTRUCTION CONTRACT NO.: W912HN19D2000/ DO W912DR20F0205

Date: 29 October 2021

US Army Corps of Engineers

Baltimore District

ARCHITECT/DESIGN:

Stantec Architecture Inc.

4798 New Broad Street, Suite 100

Orlando, Florida 32814

FINAL SUBMITTAL

FURNITURE, FIXTURE & EQUIPMENT (FF&E)

BATTALION OPERATIONS FACILITY PN91018 / P2 477925

Humphries Engineering Center Alexandria, VA

Index

1. Design Analysis

2. Floor Plans AE101; AE102; AE103

3. Furniture Plans IF101; IF102; IF103

4. Demountable Walls Plans IF201; IF202; IF203

5. Demountable Walls Elevations IF400

6. Audio Visual TA001; TA101; TA102; TA103; TA401; TA402;

TA501; TA502; TA503; TA504

7. Cost Estimate Summary

8. Procurement Data Sheets and Specifications

9. Furniture Finish Boards

BINDER PREPARED BY:

Lori Carson, NCIDQ

Stantec Architecture Inc.

4798 New Broad Street Suite 100

Orlando, Florida 32814

P: 407.425.2500

DIVIDER 1

BATTALION OPERTATIONS FACILITY

ALEXANDRIA, VA

3.9

3.2 ARCHITECTURAL

3.2.1 General Parameters

UFC 1-200-01-DOD Building Code (2019)

UFC 1-200-02-High Performance and Sustainable Building Requirements, with Change 4 (2019)

UFC 1-300-09N-Design Procedures (2005)

UFC 3-101-01-Architecture with Change 5 (2019)

UFC 1-300-02, Unified Facilities Guide Specifications with Change 2 (UFGS) Format Standard (2019)

UFC 3-110-03-Roofing with Change 4 (2019)

UFC 3-120-10-Interior Design (2018)

UFC 3-190-06-Protective Coatings and Paints (2004)

UFC 3-600-01-Fire Protection Engineering for Facilities with Change 4 (2020)

UFC 4-010-01 - DoD Minimum Antiterrorism Standards for Buildings (2018)

UFC 4-010-05 Sensitive Compartmented Information Facilities Planning, Design, And Construction, with Change 1

(2013)

AR 405-70- Utilization of Real Property (2006)

Intelligence Community Directive (ICD/ICS) 705

International Building Code (IBC) (2018)

Virginia Statewide Building Code (2018)

National Fire Protection Association (NFPA) 101, Life Safety Code (2018)

Architectural Barriers Act (ABA) Standards (2015)

ASHRAE Guidelines 0 (2013)

ASHRAE Guidelines 1.1 (2007)

ASHRAE 90.1-2016, Energy Standard for Buildings Except Low-Rise Residential Buildings (2016)

ASHRAE 189.1-2014, Standard for the Design of High-Performance Green Buildings, Except Low-Rise Residential

Buildings (2014)

3.10

3.2.2 Functional and Technical Requirements

The facilities on HEC traditionally are purpose built, secure, and technology driven in service of the soldiers and civilians they serve. More recently the United States Special Operations Command (USSOCOM) has initiated design and construction of facilities to support the Special Operations Forces (SOF) that will operate on HEC. Recently, the development of a Humphreys Engineer Center masterplan was commissioned by the Baltimore District, which will bring context to future facilities and infrastructure on the installation. The pre-final document titled “Real Property

Master Plan” was completed and dated July 10, 2020. The typical exterior materials that sheathe the existing HEC structures are precast concrete and tinted glazing.

The new BOF is intended to work alongside the developing master plan and provide an architectural context that will work harmoniously with the development of guidelines being established by the master plan. Care is taken to design the new BOF to feel a part of the current structures as well as the planned structures of the growing HEC installation.

The exterior finishes for the facility are planned to correspond with the context of the exteriors of the surrounding buildings and start to give a new precedent for future buildings as well. The new BOF will be constructed of modular precast concrete sandwich panels, metal panels and glazing systems to add texture and scale to the building.

The building has both secure and non-secure spaces. In accordance with UFC 4-010-05 and ICD/ICS 705 a design is presented that allows personnel to enter the BOF thru an access controlled entry point into a non-secure entrance vestibule and associated unclassified areas that include restrooms, wellness room, personnel cages and conferencing spaces. From the non-secure space visitors will enter a secure sally port from which they may enter through access control doors either the secure/classified areas of the building or into a collocation office space where temporary personnel with temporary clearance work, until full security clearance is given.

Building Code Summary: The BOF is classified as mixed occupancy without separation, consisting of Storage and

Business occupancies. Construction type is designated as Type IIB.

3.2.3 Design Objectives and Provisions

Exterior Construction and Features

The new BOF is designed as a three-story structure, consisting of 43,100 gross square feet, with all three levels above grade. The building structure consists of slab on grade concrete floor, spread footing foundations with aggregate piers, structural steel skeleton with concrete floors on metal deck. Roof structure is steel joists supporting metal roof deck.

The exterior walls consist of 11-inch thick architectural precast concrete sandwich panels on Level 1. The upper levels (Levels 2 and 3) consist of metal panel rainscreen system over 2-inch continuous rigid insulation, air barrier, 5/8-inch exterior sheathing, 6-inch metal stud infilled with batt insulation and 2 layers of 5/8-inch gypsum wall board.

Continuous sealant is applied at the top and bottom of all metal stud tracks. This exterior wall design provides a minimum combination R value of 20 for the precast sandwich panel, and a minimum R value of 20.5 for the metal panel rain screen system on the second and third levels.

Exterior doors and frames are insulated galvanized hollow metal. Key card access is required at all exterior doors.

Doors at the entry to the main building is a storefront system with key card access. Doors have continuous hinges, 3.11 closers, panic devices or locksets as appropriate and weather stripping. The facility includes insulated overhead sectional doors, 10-feet x 12-feet, with high-lift track and power operators at the garage bay, and 10-feet x 10-feet, with high-lift track and power operator at the load out space.

All exterior windows meet the criteria of UFC 4-010-01, DoD Minimum Antiterrorism Standards for Buildings, for this facility.

The roofing system is an Ethylene Propylene Diene Monomer (EPDM) membrane system, 1 layer, ½-inch glass-mat faced gypsum decking sloped polyisocyanurate rigid insulation (4-inches minimum insulation), vapor barrier, 5/8 exterior roof sheathing, and metal decking. The roof is sloped a minimum 1/2-inch per foot towards interior roof drains

(upper roof) and toward overflow drains/scuppers with downspouts (lower roof).

The surrounding parapet is comprised of a galvanized sheet metal parapet cap and continuous cleat with a full-strength fluoropolymer 3 coat finish, 6-inch light gage metal framing, ½-inch gypsum sheathing with glass mat facing

(both sides), and waterproofing membrane (both sides).

All roofs have a minimum R-value of 30.

The primary exterior materials of the building are precast concrete sandwich panels, a metal panel rain screen system and glazing systems. Color and texture match nearby recently constructed buildings and maintain conformance with the evolving Installation Master Plan. The cavity wall has exterior sheathing, waterproof membrane and flashing to maintain the integrity of the wall and provides control of moisture within the wall cavity. Continuous 2-inch rigid insulation (minimum R-7.5 ci.) insulation around the entire exterior enclosure of the building and 6-inch batt insulation (minimum R-19) within the stud cavity meet the required energy budgets and requirements for thermal resistance of R-20 insulation at walls and R-30 batt insulation at the roof. The overall design detailing provides a continuity of wall and roof insulation and air barriers included as required to prevent the transmission of air and moisture through the walls and roof. The exterior skin of the building will be tight to minimize infiltration and drafts along the perimeter walls. The interior face of exterior cold formed stud wall is enclosed with 2 layers of 5/8-inch gypsum wall board and painted as required.

Exterior windows are provided as shown on the exterior elevations of the building. Exterior windows are clear low-e insulated laminated glazing meeting the requirements of the UFC 4-010-01 - DoD Minimum Antiterrorism Standards for Buildings. All windows are fixed and designed for a sustained wind speed of 115 mph. Aluminum framing is pre-finished, color to be clear anodized. Aluminum storefronts are pre-finished and glazed with double-pane, insulated, clear, low-e, laminated glass. Exterior doors and frames are either insulated metal doors set in hollow metal frames or aluminum storefront doors including either wide or medium stile glazing and are pre-finished. Insulated hollow metal doors and frames are field painted. Glazing is clear and insulated low-e glass. Door hardware is stainless steel and mortised with all locks having a removable core with seven pin tumblers. Hinges have non-removable pins and antifriction bearing hinges. Exit devices are touch bars in lieu of conventional crossbars and arms. Aluminum storefront doors have the touch bar installed in the factory. Keying of all doors is in accordance with the installation standards. Lever handles are used throughout the facility. All exterior doors have a sign located per installations standards, indicating the name of the room to which it enters. The signage has raised braille lettering beneath the room name.

3.12

A new exterior accessible route connects with the new sidewalk along the south building façade and provides access to the public way. New exterior plazas and sidewalks meet ABA and Uniform Federal Accessibility Standards (UFAS) standards. See Section 3.1 CIVIL for areas of the existing parking area to be restriped and laid out to reconfigure the location of accessible parking spaces.

Building Envelope Air Tightness Design and Testing

To ensure the building design and the air barrier materials meet the needs of the project and requirements set forth in the UFC standards, the design team has incorporated in the project specifications laboratory testing standards of

ASTM E-2357 which tests air barrier materials for air leakage and ASTM E-799 which tests the completed building. In accordance with the requirements of the UFC standards, if the building fails the air barrier testing described, a

Thermographic Inspection will be performed in accordance with ASTM C1060-90 on the entire building envelope while the building is pressurized to determine the corrective action required.

Roof

The building roof is a combination of low slope roofs. The low (1/2 inch per foot slope) roof is 0.090 inch fully adhered EPDM membrane roofing with a solar reflective index (SRI) rating of 78 min and a 20-year warranty. The roof membrane is placed over rigid roof insulation (R-30 minimum) on metal decking supported by open web steel joists. The roof assembly provides a total R-Value of R-30. The EPDM roofing membrane has a white coating that achieves an SRI rating of 78 minimum, which allows sustainable credit Heat Island Reduction to be achieved. Access to the upper roof is by a roof hatch accessed from a small room on Level 3 adjacent to Stair Number 1.

A roof drainage system with both internal drains with overflow drains is provided for the high roof in the building design, while the low roof area will consist of thru wall scuppers to conductor heads to external downspouts. The drainage is designed to carry the water to the underground storm water collection system. The roofing design complies with UFC 3-110-03-Roofing” and UFC 3-101-01-Architecturel and Interior Design Requirements” for additional roofing requirements.

On the lower roof, south building corner, the user requested the incorporation of an exterior satellite pad for testing of equipment. Access to this pad is from the second level through secure space. The design uses continuous galvanized steel channels that are mounted to a raised concrete pad. These channels provide a mounting support system for secure tie downs for satellite transmitter antennas during testing. This perimeter of the satellite pad is protected with guardrails for fall protection

Signage, Area and Fixture Calculations, and Accessibility

All exterior and interior signage will meet installation requirements and standards, as well as Architectural Barriers Act

(ABA) requirements. Individual rooms, workstations and suites will be identified with permanent or interchangeable signage at each location.

Area calculations are based on a combination of factors. Where rooms are typical business use the occupancy is based on the measured area and calculated at 150 square feet per person. When density exceeds one person per

100 square feet the actual predicted occupancy for that area has been used. Classrooms are calculated at 20 square feet per person and Break Areas and Conference Rooms are calculated at 15 square feet per person. Storage

3.13 rooms, service rooms, mechanical and electrical rooms and primary server rooms are calculated with a 500 gross occupant load factor.

Fixture quantities are based on occupancy calculations as stated in Appendix F. Showers are provided for both men and women restrooms on Level 2 and Level 3. A Wellness Room is provided on Level 1 in the non-secure area located next to the restrooms.

The public areas of the BOF comply with the ABA Accessibility Standard for Department of Defense Facilities dated

2015. The facility will be designed for able-bodied military personnel and will meet the ABA standards. A new exterior accessible route connects with the new sidewalk along the south building façade and provides access to the public way. New exterior plazas and sidewalks meet ABA and UFAS standards. Existing parking areas will be restriped and laid out to reconfigure the location of accessible parking spaces.

Interior Construction and Features

Interior construction includes interior partitions, interior doors and fittings, floor and ceiling finishes, and fixed cabinetry and equipment. Construction is durable as appropriate to the building’s use, and as required by the government. For general use, all interior and corridor partitions are constructed of cold-formed non-load bearing studs as agreed with the users during programming. These walls are covered with impact resistant drywall depending on space requirements. Interior partitions meet specified Sound Transmission Class (STC) ratings as discussed with the user during programming exercises. All partitions are supported from the floor and braced to the structure above if they do not extend to the deck above. The interior doors in the office areas are stain-grade, extra heavy duty, solid core wood set in hollow metal frame, doors in back of house areas on the first floor and accessing utility rooms are heavy duty hollow metal doors set in hollow metal frames. STC, fire, and smoke rated doors are provided where required. Interior glazing for door lites, vision panels, and interior view windows are 1/4-inch tempered clear glass, fire glass or laminated glass depending on the application. Door hardware is high quality mortised with satin stainless-steel finish. Toilet accessories and partitions are provided in each restroom as required. All accessories are stainless steel. An interior signage system is provided throughout the interior of the facility meeting installation requirements and standards. The signs are 1/8-inch thick engraved acrylic, meeting all the requirements of the ABA for tactile letters in braille and symbols where applicable. Full height corner guards are heavy duty, premium grade stainless steel and are provided at all outside corners susceptible to damage. All cabinets are plastic laminate and constructed to meet “Custom” quality grade as defined in Architectural Woodwork Institute (AWI) Quality Standards. A recessed removable floor mat is provided at the primary building entrance.

Structural Interior Design

The building has been designed to have an inviting office feel with porcelain tile floors installed over sound absorbing acoustical impact sheet membrane in service areas, restrooms areas and corridors with painted abuse resistant gypsum board walls. The built-in millwork features laminate clad millwork with solid surface countertops in service areas. Warm rich colors and finishes are used throughout the facility. Restroom walls feature floor-to-ceiling porcelain wall tile. The working bay areas on the first floor are sealed concrete for durability.

General building finishes are as follows: main corridors and lobby features porcelain tile flooring with cove base, office areas have carpet, restrooms have porcelain tile floors and utility areas have sealed concrete. Open office spaces have carpet floor surfaces with a modern inviting pattern. On the second and third levels carpet is placed

3.14 over raised access flooring. Ceilings are acoustical ceiling tile in the office and work areas. The storage and support spaces are exposed ceilings with painted structure above. Moisture resistant gypsum board ceiling is used in wet areas. All mechanical, electrical, communication and elevator machine rooms are exposed painted structure.

The interior finishes selected are warm and inviting patterns chosen to be long lasting. Finishes are durable, aesthetically pleasing, functional, and low maintenance. They are chosen to accompany the flexibility of the space and coordinated with the demountable walls and raised access floors.

Construction of interior partition systems generally adheres to the following detailed description:

Where walls extend to underside of deck (i.e. spaces dividing user groups, corridors, secure rooms, storage areas above 100 square feet needing a smoke barrier, and where spaces contain toilets or showers), 3 5/8-inch metal stud walls are used with gypsum board on both sides to the underside of deck.

Within areas where walls do not need to extend to the underside of deck, walls are 3 5/8-inch metal stud with gypsum wall board on both sides extending from on top of the floor to 6-inches above finished ceiling.

Where vertical shafts are located, a 6-inch metal stud (C-H type) are used with two layers of 5/8-inch fire resistant gypsum wall board on one side and 1-inch shaft liner on other side.

Drywall Modifications are as follows:

5/8-inch water resistant drywall is used in restrooms.

5/8-inch cement board is used in parts of rooms with showers and under ceramic tile.

5/8-inch impact resistant drywall is used in all corridors.

Walls surrounding conference rooms and classrooms is comprised of 3 5/8-inch metal studs, with 1 layer of gypsum wall board on one side and 2 layers of gypsum wall board on the other side, extending from slab to slab. Walls contain 4-inch sound attenuation batts, and continuous acoustical sealant is used. A minimum STC of 45 is provided for office suites; A minimum STC of 50 is provided for rooms with amplified sound. ie. with Video Teleconferencing equipment (VTC).

One-hour fire-rated construction walls are used around vertical circulation elements (i.e. stairs, and elevator shafts) on all levels in the building. The wall design is based on the UL U415 test number, consisting of two layers of 5/8-inch type X gypsum wall board, a 4-inch C-H stud (25 gauge 24-inches on center) and 1-inch shaft liner on the shaft side.

All shaft walls are designed and coordinated with structural framing to meet progressive collapse requirements as stated in the structural requirements.

Doors are solid core flush wood doors in hollow metal frames. Fire rated doors and frames are used where required by code. Hardware typically consists of butt hinges, lockset, wall stop, closers at suite entrance doors and fire doors.

Key card access is required into all suites and doors leading from stairwells into the floors they serve (including roof).

Interiors doors and their frames maintain the STC rating of the walls in which they are placed. Ratings for acoustic doors will be based on manufacturer field tested values.

3.15

Stair construction is concrete filled metal pan on steel channel stringers.

Interior Finishes and Furnishings

Carpet tile is used throughout the office area with one-to-one positioning tabs to maintain alignment with the raised floor panels. Accent tiles are used for visual interest and to help locate electrical and data hubs under the access floor. Corridors on first floor have porcelain tile and Break Area and have resilient vinyl tile. All walls are painted except as noted. Conference rooms have carpet flooring and painted walls. Whisper zones have a separate carpet pattern to identify the spaces as needed throughout the building.

Raised access flooring will be 24-inch x 24-inch, 18-inches tall and will be provided throughout most of Level 2 and

Level 3 along with demountable partition walls for flexibility to reconfigure the space in the future. The demountable partitions are in a variety of finishes from laminate panels and wall coverings as needed for each space function. The walls have glass panel inserts to allow natural light into the interior of the space.

One 4000-pound machine room less hydraulic passenger elevator with 8-foot tall doors will be provided. The elevator has removable wall pads and stainless-steel doors, frames, hall call and monitor stations, elevator car front and code required safety features. Interior elevator finishes are stainless steel, flooring with luxury vinyl tile as specified.

Finish carpentry in the Break Areas and Wellness Room will be plastic laminate and countertops will be solid surface.

Each Conference Room and Classroom has multiple marker board track system with tack board to cover classified information. The boards will be in lengths to fit the spaces. All markerboards in the facility are this track system for security of classified information.

Storage shelving located in the personnel and team cages is pre-manufactured metal shelving units and provided as part of the Furniture, Fixtures and Equipment (FF&E) package.

Signage, as stated earlier, will be durable and interchangeable and is provided throughout the interior of the building.

Break Area and Wellness Room appliances are provided and specified in Specification section 11 31 13.

3.3 STRUCTURAL

The BOF is a rectangular shaped three-story building. The exterior walls consist of non-load bearing precast architectural panels at the Level 1 and metal panel at each level above.

3.3.1 General Parameters

The BOF structural framing system is composed of conventional steel framing with in-fill non-load bearing metal stud framing. The floor construction type is steel frame with elevated reinforced concrete floors supported by composite beams. The roof consists of metal deck roofing system supported by steel bar joists and supplementary beams at cantilever conditions. Level 1 will be reinforced concrete slab-on-grade, vapor barrier, and granular base. The foundation level consists of column supporting spread footings bearing on aggregate piers as recommended by the geotechnical report.

FURNITURE, FIXTURES, AND EQUIPMENT (FF&E) BOARDS

Battalion Operations Facility PN 91018 / P2 477925

Humphrey’s Engineer Center, Alexandria, Virginia

CH-4 Training Chair & CH-12

Breakroom Stool

Poly – Variable Blue

CH-6 & CH-7 Lounge Chair & Sofa

Seat Upholstery

Leather – Teak

CH-8 & CH-9 Lounge Chair & Sofa

Seat Upholstery

Crag Tech – 4059-07

CH-1 Desk Chair

Seat Back Fabric – Mesh

Brier

CH-1 Desk Chair & CH-3

Guest Chair

Seat Fabric

Brier

CH-2 Executive Chair

Seat Fabric

Leather - Juniper

CH-3 Guest Chair

Seat Back Fabric – Mesh

Black

CH-5 Side Chair

Seat Fabric

Stimuli - Sensitive

CH-9 Modular Sofa

Seat Back Upholstery

Sagebrush Tech – 4059-10

Humphrey’s Engineer Center, Alexandria, Virginia

CR-2 Credenza, T-1 Breakroom Table, T-

5 Training Table, T-9, T-10 End & Coffee

Table, T-16 Worktable

Laminate Top

Storm White

D-1, D-3, D-4, D-6, D-7 Workstation

& T-15 Printer Table

Laminate Top & Edge

Walnut Cathedralgrain

CR-2 Credenza, Laminate Front

Greystone

CH-10 Rocker Chair

Leg Finish

Iron

D-1 Workstation, ST-11

Pedstal, ST-12 File Cabinet, WB-3 Touchdown Station

Metal Panel Trim Finish

Storm White

CH-11 Breakroom Chair

Seat & Back Fabric

Vinyl – Black Oxide

CH-10 Rocker Chair

Seat Fabric

OFS Terra Shale

D-1 Workstation, WB-3

Touchdown Station

Panel Fabric

Wired Up – Drawplate 1017-02

T-9 Coffee Table, T-10

Round Table

Base Laminate

Greystone Beech

Humphrey’s Engineer Center, Alexandria, Virginia

CR-1 Credenza D-2, D-5

Executive Desk,T-4, T-6, T-12

Meeting Tables

Wood Finish

Cocoa Brown Flint

ST-2 Personal Cages

Metal – Blue Grey BG (25)

T-2 Side Table, T-7 Coffee

Table, T-8 End Table, T-11

Laptop Table

Wood Finish

Basque White Oak

T-13 Community Table

Laminate

Drift Oak

T-16 Worktable, X-4 Mobile

Whiteboard

Base

Soft Gris

X-2, X-3 Whiteboard

Tackboard Fabric

Shiitake 029

ST-7 Bookcase, T-1, T-12

Tables

Laminate

Cocoa Brown Flint

CH-5 Chair Frame, T-7, T-8

End & Coffee Table

Stain

Cocoa Brown (DY)

DIVIDER 2

T

UP

UP

ALIGN

ALIGN

ALIGN

A L

IG

N

ALIGN

ALIGN

ALIGN

ALIGN

ALIGN

ALIGN

ALIGN ALIGN

ALIGN

A L

IG

N

A

A E

GCBA

GSB (STE) 3 BAY

GARAGE

GSB FCC

LOGISTICS AREA

& SECURE

LOADOUT

LOADOUT

GSB FCC

MISSION

SUPPORT

DMARC125

FCO TEAM CAGE

GSB MISSION

TEAM CAGE

FCO TEAM CAGE

FCO TEAM CAGE

EL-1

ELEVATOR

ENTRY

VESTIBULE

COLLATERAL

FIRE

ELECTRICAL

CONFERENCE

MEETING AREA

A

A E

G1

AE201

PERSONAL

CAGES

S-1

STAIR 1

C O

R R

ID

O

R

WELLNESS

JC133

CORRIDOR

S4 STORAGE

STORAGE

E

ELEVATOR

LOBBY

S-2

STAIR 2

A1

AE301

A1

AE301

A1

AE302

A1

AE302

A1

AE303

A1

AE303

H1

AE301

H1

AE301

G1

AE302

G1

AE302

H1

AE303

H1

AE303

H1

AE304

H1

AE304

A1

AE304

A1

AE304

WOMEN

MEN

RECEPTION

AREA110

SALLY PORT

S-2A

A

C

B

A

110B

110A

109A

110D

110C

126B

C

S -1

A

B

133A

128A

B

S -1

B

B

A

B

A

127B

C

129A

B.5 F

3.5

2.3

CORRIDOR

D

2.5

2.6

FCO TEAM CAGE

CORRIDOR

CORRIDOR

C O

R R

ID

O

R

1'-8" 21'-8" 42'-6" 16'-7" 19'-4" 7'-5" 13'-1" 11'-8" 5'-4" 10'-1" 2'-4" 2'-4" 19'-4" 1'-8"

AE403

A2

AE401

A2

AE407

H2

AE406

A8

MECHANICAL

TR

B.6

3.6

C.8 E.5D.8B3

E Q

E Q

20'-4" 11'-1" 7'-2" 1'-9"

13'-8" 21'-7" 9'-3" 16'-9" 9'-5" 12'-3" 18'-4" 7'-8" 22'-5" 1'-8"

175'-0"

13'-2"

1'-8"

MECHANICAL

YARD

COOLING TOWER

CONDENSING

UNITS

GENERATOR

175'-0"

LINE OF OVERHANG ABOVE

9'-4"

METAL STORAGE CAGE PER MIL-M-17194,

TYP AT FCO TEAM CAGES, STORAGE 134,

AND GSB MISSION TEAM CAGE 120

59 PERSONAL CAGES

107A

SF4

A

B

100D

100C

SF1

S F

6-TIER LOCKERS,

TYP OF 7

AE409

A1

AE409

J7

AE409

A7

F.3

2.8

11A

11A

11A

11A

11A 11A 11A

11A

11A

11A

11A

11A

11A 11A

11A

12A

12A

12A

12A

13A

12A

1A

13A

11A

11A

13B

1A

1A

1A

1A

1A

1A

12A 12A

1A

1A

1A

1A

1A

1A

1C

1A

1A

1A

6A

6A

6A

6A

6B

1A

10'-0" WIDE ORNAMENTAL FENCE GATE

7'-0" TALL ORNAMENTAL FENCE

DOWNSPOUT AND BOOT,

TYP OF 4 ON THIS FACADE

DOWNSPOUT AND

BOOT , TYP 3 ON

THIS FACADE

AE603

A14

AE603

A14

AE501

K2 TYP

10'-0" WIDE

ORNAMENTAL

FENCE GATE

AE501

F14

AE501

F8

AE501

A8

AE501

F2

AE510

H14

AE510

H8

AE510

A1

ELECTRICAL

2'-4"

AE510

A14

AE511

F7

AE510

A8

11A

11A

1'-0"

MIN

1'-0"

AE502

H1

AE511

A7

AE502

H7

5 PERSONAL CAGES

7'-5" 13'-3"

8'-9" 4'-6"

1'-9" 1'-3"

5'-0" 2'-11" 12'-7"

5'-8" 5'-8"

8"

11'-0"

2'-8"

10'-7"

5'-7"

15'-8"

13A

10'-4"

13'-5" 15'-9" 9'-7" 2'-0"

13A

AE511

F13

AE511

A13

1A

AE510

H8

AE510

H8

1A

1A

1A

" 1'-6"

9'

0" T

Y P

21'-7"

3'-4"

9" 10'-5"

1A1A

4'-1"

9"

EQ EQ

" 8

E Q

E Q

1'-9"

23'-5"

3'-0" WIDE ORNAMENTAL

FENCE GATE W/ PANIC

HARDWARE

FOR FENCE/GATE DETAILS

AE501

K14

SIM

NO R-FOIL

REFER TO SHEET AE413

AE501

A14

SIM

MAINTENANCE ACCESS ROAD

LINE OF CONCRETE

PAVEMENT, SEE CIVIL

C O

N C

R E

T E

P A

V E

M E

N T

S

E E

C

IV

IL

FLOOR DRAIN,

SEE PLUMB

BOLLARDS,

TYP OF 4

BOLLARDS,

TYP OF 2

1'-0"

5'-2"

G1

AE202

/8

" 1

"1

SIM

COORDINATE OVERHEAD

UTILITIES WITH CAR LIFT.

UTILITIES TO AVOID CAR

LIFT AREA

AE603

A6

AE603

A6

1. UNLESS NOTED OTHERWISE, ALL

DIMENSIONS ARE TO:

- FACE OF GWB

- FACE OF CONCRETE

- CENTERLINE OF DEMOUNTABLE

PARTITIONS

2. SEE MECHANICAL, ELECTRICAL,

PLUMBING, AND FIRE PROTECTION

(M.E.P.) DRAWINGS AND ENLARGED

ARCHITECTURAL PLANS FOR

INFORMATION NOT SHOWN ON THIS

SHEET.

3. COORDINATE AND PROVIDE

BLOCKING IN PARTITIONS FOR THE

INSTALLATION AND ATTACHMENT

OF ALL WALL MOUNTED EQUIPMENT

AND PRODUCTS. ALL CONCEALED

BLOCKING SHALL BE FIRE

RETARDENT TREATED. SEE

ARCHITECTURAL PLANS, AND MEP

AND AV DRAWINGS FOR THE

LOCATIONS OF WALL MOUNTED

EQUIPMENT AND PRODUCTS.

4. WHISPER ZONES AS SHOWN ON

PLAN SHALL BE DESIGNATED WITH

WALL SIGNAGE OR FLOOR

MARKINGS. THESE ZONES WILL BE

NO DISCUSSION ZONES WHERE NO

CONVERSATIONS DEALING WITH

CLASSIFIED INFORMATION WILL BE

ALLOWED.

5. SEE SHEETS AE701-AE703 FOR

INTERIOR PARTITION TYPES

6. SECURE BORDER WALLS TO BE

ICD/ICS-705 AND UFC 4-010-05

COMPLIANT. CONTRACTOR TO

MEET ALL RELEVANT

REQUIREMENTS FOR

ACCREDITATION.

GENERAL NOTES

RAISED ACCESS FLOOR

WALK OFF MAT

(FLOOR GRILLE)

WHISPER ZONE

SECURE BOUNDARY

FLOOR PLAN LEGEND

XX#

WINDOW, CURTAINWALL,

STOREFRONT TAG. SEE

AE602

12 WALL TYPE TAG

FLOOR DRAIN, SEE

PLUMB DRAWINGS

TAPERED INSULATION,

SEE ROOF PLAN

J

O N

E S

F R

A N

K L

IN

R

D

S U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

4' 8' 16'

PROJECT

NORTH

TRUE

NORTH

B A

L T

IM

O

R E

D

IS

T R

IC

T

H

O P

K

IN

S P

L A

Z A

B A

L T

IM

O

R E

M A

R Y

L A

N D

F

IL

E N

A M

E

CONTROLLED UNCLASSIFIED INFORMATION

X X

X -X

X X

-X X

X

X X

X -X

X X

-X X

X

B

C

D

E

F

G

H

J

K

L

M

N

P

11 12 13 14 15 16 17 18 19 20

D R

A W

IN

G

N O

F

-2

-1

PROPERTY OF UNITED STATES GOVERNMENT, CONTROLLED UNCLASSIFIED INFORMATION (CUI), DISSEMINATION, AND DISTIBUTION TO AUTHORIZED INDIVIDUALS PROHIBITED

AE101

F L O

O R

P L A

N

L E

V E

L

H U

M P

H R

E Y

S E

N G

IN

E

E R

C E

N T

E R

A

L E

X A

N D

R

IA

V

IR

G

IN

IA

P Z

O O

K

IB

U

S T

A M

A N

T E

W B

Y N

U M

M B

O W

L E

S

O

C T

O B

E R

A E

.D

W G

B A

T T

A L

IO

N O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

P N

P

1/8" = 1'-0" A1

FLOOR PLAN - LEVEL 1

GROSS BUILDING SF

LEVEL AREA

LEVEL 1 17500.00 SF

LEVEL 2 12800.00 SF

LEVEL 3 12800.00 SF

TOTAL 43100.00 SF

DN

UP

DN

UP

A L

IG

N

A L

IG

N

ALIGN

GCBA

FCC LAB

EL-1

ELEVATOR

G1

AE202

A

A E

G1

AE201

WOMEN 205

TR

MECHANICAL

S-1

STAIR 1

FARADAY CAGE

IT/COMMS

STORAGE

OPEN OFFICE

FCC TEAM 2

FCC TEAM 1

FCC TEAM 3

FCC TEAM 4

BREAK AREA

CORRIDOR

MEN

CONFERENCE

ROOM

O4 PRIVATE

OFFICE

E

O4 PRIVATE

OFFICE

UPS

FCC CUBES

O4 PRIVATE

OFFICE

S-2

STAIR 2

A1

AE301

A1

AE301

A1

AE302

A1

AE302

A1

AE303

A1

AE303

H1

AE301

H1

AE301

G1

AE302

G1

AE302

H1

AE303

H1

AE303

H1

AE304

H1

AE304

A1

AE304

A1

AE304

SATELLITE PAD

B.5 F

3.5

2.3

S -2

B

203202

LOWER

ROOF

D

2.5

S -1

C

2.6

AE403

A8

AE401

A8

AE408

A1

AE406

G8

LOWER

ROOF

B.6

3.6

C.8 E.5D.8B3

20'-4" 11'-1" 7'-2" 1'-9" 13'-8" 21'-7" 9'-3" 16'-9" 9'-5" 12'-3" 18'-4" 7'-8" 22'-5" 6'-11"

160'-0"

4'-0" 4'-0" 16'-0" 4'-0" 8'-0" 4'-0" 8'-0" 4'-0" 8'-0" 4'-0" 8'-0" 4'-0" 8'-0" 4'-0" 8'-0" 4'-0" 8'-0" 4'-0" 16'-0" 4'-0" 8'-0" 20'-0"

124'-0" 36'-0"

A

A E

1'-9"

1'-9"

6'-11"

SF3

SF3

SF3 SF3 SF3 SF3

SF3 SF3 SF3 SF3

CW3

C W

S

F

S F

S

F

AE410

A4

AE410

K4

AE503

A5

AE604

F8

AE502

A7

AE604

F14

F.3

10'-4"19'-8"14'-4"8'-8"5'-0"5'-0"11'-0"

2.8

FLOOR

DRAIN

1B

1B 1B

1B

1B 1B

1B

1A

1A

10 10

12A 1A

1A

4B

1A

1A

4B

4B

12A

12A

12A

12A

DOWNSPOUT BELOW, TYP

GALV STL GUARDRAIL

A10

AE508

AE502

H14

AE502

A1

AE512

A8

AE413

F8

AE502

A14 SIM

COMSEC

AE512

A2

AE503

H12

AE512

A2

AE512

A2 AE512

A2

AE512

A2

AE512

A2

AE512

A2

AE512

A2

AE512

A8

AE512

A8

AE512

A8

AE512

A8

X-8

X-7

X-9

X-7

X-8

X-8

X-7

X-10

X-5

X-8

X-7

X-9

X-7

X-8

AE503

H5 10'-5" 2

3'-0"

11'-7"

4'-9" 18'-0" 3'-5"

8'-8"

1A

1A

9'-8" 2'-4"

8'-1"

AE512

A2

AE502

A1

8'-9"

5'-7"

EQ EQ

1'-3"

F

A E

AE413

F14_______

A10

AE508

BOUNDARY OF

FCC CUBES, FOR

REFERENCE ONLY

BOUNDARY OF

FARADAY CAGE,

FOR REFERENCE

ONLY

TYP

O4 PRIVATE

OFFICE

X-5

X-8

H10

AE508

TYP

H10

AE508

ELEVATED FLOOR AT TOILETS,

SEE STRUCTURAL

ELEVATED FLOOR AT

MECHANICAL, SEE STRUCTURAL 4

TYP

4'-0"

C-CHANNELS MOUNTED

TO PAD FOR SECURING

SATELLITES TO ROOF

TOP PAD

RAISED ACCESS FLOOR

WALK OFF MAT

(FLOOR GRILLE)

WHISPER ZONE

SECURE BOUNDARY

FLOOR PLAN LEGEND

XX#

WINDOW, CURTAINWALL,

STOREFRONT TAG. SEE

AE602

12 WALL TYPE TAG

FLOOR DRAIN, SEE

PLUMB DRAWINGS

TAPERED INSULATION,

SEE ROOF PLAN

J

O N

E S

F R

A N

K L

IN

R

D

S U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

4' 8' 16'

PROJECT

NORTH

TRUE

NORTH

B A

L T

IM

O

R E

D

IS

T R

IC

T

H

O P

K

IN

S P

L A

Z A

B A

L T

IM

O

R E

M A

R Y

L A

N D

F

IL

E N

A M

E

CONTROLLED UNCLASSIFIED INFORMATION

X X

X -X

X X

-X X

X

X X

X -X

X X

-X X

X

B

C

D

E

F

G

H

J

K

L

M

N

P

11 12 13 14 15 16 17 18 19 20

D R

A W

IN

G

N O

F

-2

-1

PROPERTY OF UNITED STATES GOVERNMENT, CONTROLLED UNCLASSIFIED INFORMATION (CUI), DISSEMINATION, AND DISTIBUTION TO AUTHORIZED INDIVIDUALS PROHIBITED

AE102

F L O

O R

P L A

N

L E

V E

L

H U

M P

H R

E Y

S E

N G

IN

E

E R

C E

N T

E R

A

L E

X A

N D

R

IA

V

IR

G

IN

IA

P Z

O O

K

IB

U

S T

A M

A N

T E

W B

Y N

U M

M B

O W

L E

S

O

C T

O B

E R

A E

.D

W G

B A

T T

A L

IO

N O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

P N

P

1/8" = 1'-0" A1

FLOOR PLAN - LEVEL 2

GROSS BUILDING SF

LEVEL AREA

LEVEL 1 17500.00 SF

LEVEL 2 12800.00 SF

LEVEL 3 12800.00 SF

TOTAL 43100.00 SF

REFER TO SHEET AE101

FOR GENERAL NOTES

NOTE: SEE IF201 - IF203 SHEETS FOR "X" WALL TYPES

A L

IG

N

GCBA

HHT PRIVATE

OFFICE

CG

CONFERENCE

ROOM

CONFERENCE

ROOM

CG PRIVATE

OFFICE

TOILET

CG PRIVATE

OFFICE

CG PRIVATE

OFFICE

G1

AE202

A

A E

G1

AE201

EL-1

ELEVATOR

MEN

WOMEN

MECHANICAL

TR

G4 PRIVATE

OFFICE 324

G4 PRIVATE

OFFICE

SPO PRIVATE

OFFICE

SPO PRIVATE

OFFICE

S3 PRIVATE

OFFICE 320

S3 PRIVATE

OFFICE

BREAK AREA

PSYCH OFFICE

SCT SERVICE

AREA

CLASSROOM

CHAPLAIN

OFFICE

CG PRIVATE

OFFICE

E

WAITING AREA

S4 CUBES

OPEN OFFICE

AREA

S-2

STAIR 2

S-1

STAIR 1

A1

AE301

A1

AE301

A1

AE303

A1

AE303

H1

AE301

H1

AE301

G1

AE302

G1

AE302

H1

AE303

H1

AE303

H1

AE304

H1

AE304

A1

AE304

A1

AE304

B.5 F

3.5

2.3

A

313318

S-2C

312B

A

B

D

2.5

2.6

CORRIDOR

AE403

A15

AE401

A13AE406

G8 SIM

AE408

A1 SIM

AE407

A2

EXTERIOR PATIO

B.6

3.6

C.8 E.5D.8B3

A

A E

20'-4" 11'-1" 7'-2" 1'-9" 13'-8" 21'-7" 9'-3" 16'-9" 9'-5" 12'-3" 18'-4" 7'-8" 22'-5"

160'-0"

20'-0"8'-0"4'-0"16'-0"4'-0"8'-0"4'-0"8'-0"4'-0"8'-0"4'-0"8'-0"4'-0"8'-0"4'-0"8'-0"4'-0"8'-0"4'-0"16'-0"4'-0"4'-0"

1'-9"

6'-11" 16'-0"4'-0"

1'-9"

11"

S -1

D

317 314

SF3 SF3 SF3 SF3 SF3 SF3 SF3 SF3 SF3 SF3

C W

S

F

S F

S

F

CW3

AE411

A12

AE411

H12

AE504

G3

AE504

G13

AE504

A3

F.3

2.8

FLOOR

DRAIN

1D

12A

12A

1B 1B 1B

1B

1B 1B

1B

1A

1A

12A

12A 1A

1A

1B

1B 1B

1A

1A

1A

1A

1A

1A

160'-0"

AE512

F14

AE512

F8

AE504

A13

AE502

A1

AE503

A12

2'-4"

307A

ELECTRICAL

307A

ROOF ACCESS

16'-1"

6'-0" 8'-1"

11" 11"

17'-0" 17'-0"

11"

4A4A4A

AE512

A2

4A

4A

14'-0" 9'-8" 4'-4"

X-5

X-5 X-8

X-10

X-5 X-7

X-5

X-10

X-5

AE512

A8

AE512

A8

AE512

A8

AE512

A8

1'-7"

4A4A

4A

AE512

A2

11" 11"

4A

4A

4A

AE512

A2

12'-0" 12'-0" 12'-0" 12'-0" 12'-0" 11'-5" 7"

X-5

X-7

X-7

X-7

X-7

X-7X-7

X-7

2'-6" 11'-0" 5'-0" 5'-0" 8'-8" 14'-4" 19'-8" 10'-4"

10'-5"

EQEQ

1A1A

AE503

A5 SIM

AE503

H5 SIM

2" CONCRETE PAVERS ON

LEVELING PEDESTALS,

ALIGN WITH METAL PANEL

REVEALS.

A10

AE508

A4

AE508

AE103

L13

ELEVATED FLOOR AT

TOILETS, SEE STRUCTURAL

ELEVATED FLOOR AT

MECHANICAL, SEE STRUCTURAL

ELEVATED

FLOOR AT

TOILET, SEE

STRUCTURAL

3/4"

3/4"

F A

C E

O F

S T

U D

/4

FACE OF STUD

1'-3 1/2"

A

A E

AE506

A3

G11

AE506

AE506

A11

LOW

HIGH

INTERNAL ROOF DRAIN &

OVERFLOW ROOF DRAIN

UNDERNEATH PAVERS

F1

AE203

RAISED ACCESS FLOOR

WALK OFF MAT

(FLOOR GRILLE)

WHISPER ZONE

SECURE BOUNDARY

FLOOR PLAN LEGEND

XX#

WINDOW, CURTAINWALL,

STOREFRONT TAG. SEE

AE602

12 WALL TYPE TAG

FLOOR DRAIN, SEE

PLUMB DRAWINGS

TAPERED INSULATION,

SEE ROOF PLAN

3.5

A4

AE508

CHAPLAIN

OFFICE

PSYCH OFFICE

CENTERLINE OF

DEMOUNTABLE PARTION, TYP

5/8" GYPSUM WALL BOARD,

2 1/2" CFMF, SOUND

ATTENUATION INSULATION

BELOW RAISED ACCESS,

TYP

6" TYP 6" TYP

1A

TYP

J

O N

E S

F R

A N

K L

IN

R

D

S U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

4' 8' 16'

PROJECT

NORTH

TRUE

NORTH

B A

L T

IM

O

R E

D

IS

T R

IC

T

H

O P

K

IN

S P

L A

Z A

B A

L T

IM

O

R E

M A

R Y

L A

N D

F

IL

E N

A M

E

CONTROLLED UNCLASSIFIED INFORMATION

X X

X -X

X X

-X X

X

X X

X -X

X X

-X X

X

B

C

D

E

F

G

H

J

K

L

M

N

P

11 12 13 14 15 16 17 18 19 20

D R

A W

IN

G

N O

F

-2

-1

PROPERTY OF UNITED STATES GOVERNMENT, CONTROLLED UNCLASSIFIED INFORMATION (CUI), DISSEMINATION, AND DISTIBUTION TO AUTHORIZED INDIVIDUALS PROHIBITED

AE103

F L O

O R

P L A

N

L E

V E

L

H U

M P

H R

E Y

S E

N G

IN

E

E R

C E

N T

E R

A

L E

X A

N D

R

IA

V

IR

G

IN

IA

P Z

O O

K

IB

U

S T

A M

A N

T E

W B

Y N

U M

M B

O W

L E

S

O

C T

O B

E R

A E

.D

W G

B A

T T

A L

IO

N O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

P N

P

1/8" = 1'-0" A1

FLOOR PLAN - LEVEL 3

GROSS BUILDING SF

LEVEL AREA

LEVEL 1 17500.00 SF

LEVEL 2 12800.00 SF

LEVEL 3 12800.00 SF

TOTAL 43100.00 SF

REFER TO SHEET AE101

FOR GENERAL NOTES

NOTE: SEE IF201 - IF203 SHEETS FOR "X" WALL TYPES

1/8" = 1'-0" L13

FLOOR PLAN - CHAPLAIN & PSYCH OFFICE -

BELOW ACCESS FLOOR

DIVIDER 3

GSB (STE) 3 BAY

GARAGE

GSB FCC

LOGISTICS AREA

& SECURE

LOADOUT

LOADOUT

GSB FCC

MISSION

SUPPORT

DMARC

FCO TEAM CAGE

GSB MISSION

TEAM CAGE

FCO TEAM CAGE

FCO TEAM CAGE

EL-1

ELEVATOR

ENTRY

VESTIBULE

CORRIDOR

COLLATERAL

FIRE

ELECTRICAL

CONFERENCE

MEETING AREA

PERSONAL

CAGES

S-1

STAIR 1

CORRIDOR

WELLNESS

JC

CORRIDOR

S4 STORAGE

STORAGE

BBF

FF 2DR

MEN

WOMEN

CORRIDOR

S-2

STAIR 2

SALLY PORT

CORRIDOR

RECEPTION

AREA115

ELEVATOR

LOBBY

CORRIDOR

CH-1

D-1 D-1

D-1

CH-1

D-1

D-1

CH-1

CH-5

T-1

ST-1

ST-5

X-1

CH-1

CH-1

CH-1

CH-1

ST-2

(QTY 59)

MECHANICAL

TR

FCO TEAM CAGE

(QTY. 4)

ST-1

ST-5

ST-6

(QTY. 3)

ST-6

(QTY. 2)

(QTY. 2)

(QTY. 3)

ST-1 ST-6 ST-5

(QTY. 6) (QTY. 2) (QTY. 4)

ST-1 ST-6 ST-5

(QTY. 6) (QTY. 2) (QTY. 4)

ST-5

ST-6

ST-1

(QTY. 3)

(QTY. 4) ST-5

ST-6

(QTY. 4)

(QTY. 6)

D-1

D-1

D-1

X-3

CH-1

D-4

(QTY. 6)

CH-5

T-12

ST-7

(QTY. 4)

X-3

X-3

X-3

X-3

X-3

X-3

X-2

X-6

ST-2

(QTY 5)

(QTY 32)

CH-10

ST-13 ST-14

T-2

(QTY. 3)

J

O N

E S

F R

A N

K L

IN

R

D

S U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

4' 8' 16'

PROJECT

NORTH

TRUE

NORTH

B A

L T

IM

O

R E

D

IS

T R

IC

T

H

O P

K

IN

S P

L A

Z A

B A

L T

IM

O

R E

M A

R Y

L A

N D

F

IL

E N

A M

E

CONTROLLED UNCLASSIFIED INFORMATION

X X

X -X

X X

-X X

X

X X

X -X

X X

-X X

X

B

C

D

E

F

G

H

J

K

L

M

N

P

11 12 13 14 15 16 17 18 19 20

D R

A W

IN

G

N O

F

-2

-1

PROPERTY OF UNITED STATES GOVERNMENT, CONTROLLED UNCLASSIFIED INFORMATION (CUI), DISSEMINATION, AND DISTIBUTION TO AUTHORIZED INDIVIDUALS PROHIBITED

IF101

L E

V E

L

F U

R N

IT

U

R E

F

IX

T

U R

E S

A N

D E

Q U

IP

M

E N

T P

L A

N

H U

M P

H R

E Y

S E

N G

IN

E

E R

C E

N T

E R

A

L E

X A

N D

R

IA

V

IR

G

IN

IA

L B

A R

N A

R D

A V

E G

A

W B

Y N

U M

J C

A R

T E

R

O

C T

O B

E R

IF

.D

W G

B A

T T

A L

IO

N O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

P N

P

1/8" = 1'-0" C2

LEVEL 1 FURNITURE, FIXTURES AND EQUIPEMENT PLAN

FURNITURE SCHEDULE

Type Mark Description Count

CH-1 DESK CHAIR 112

CH-2 EXECUTIVE CHAIR 21

CH-3 GUEST CHAIR 32

CH-4 TRAINING CHAIR 24

CH-5 SIDE CHAIR 16

CH-6 LOUNGE CHAIR 1

CH-7 SOFA 1

CH-8 LOUNGE CHAIR 2

CH-9 MODULAR SOFA 5

CH-10 ROCKER CHAIR 1

CH-11 BREAKROOM CHAIR 42

CH-12 BREAKROOM STOOL 10

CR-1 CREDENZA 54"W 3

CR-2 CREDENZA 42"W 1

D-1 WORKSTATION 65

D-2 EXECUTIVE WORKSTATION 1

D-3 PRIVATE OFFICE DESK 16

D-4 DESK 1

D-5 SERVICE COUNTER 1

D-6 DESK WITH RETURN 2

D-7 DESK 60"W 1

FC-1 FARADAY CAGE 1

ST-1 SHELVING 24X36 20

ST-2 STORAGE - PERSONAL CAGES 64

ST-3 SERVER RACKS 5

ST-4 STORAGE CASE WITH LOCK 67" H 18"W 37

ST-5 SHELVING 24X48 18

ST-6 SHELVING 24X42 12

ST-7 BOOKCASE 1

ST-8 STORAGE CABINET 3

ST-9 SAFE 5

ST-10 STORAGE CABINET WITH LOCK 3

ST-11 MOBILE PEDESTAL 4

ST-12 3H FILE CABINET 1

ST-13 LOCKER STORAGE 32

ST-14 DISPLAY CASE 3

ST-15 MEMORABILIA DISPLAY CASE 3

ST-16 BAKERS RACK 1

T-1 SMALL CONFERENCE TABLE 1

T-2 SIDE TABLE 1

T-3 BREAK ROOM TABLE 8

T-4 10-12 SEAT CONFERENCE TABLE 5

T-5 CLASSROOM TABLE 24"D 54"W 12

T-6 MEETING TABLE 1

T-7 COFFEE TABLE 1

T-8 SIDE TABLE 1

T-9 COFFEE TABLE 1

T-10 ROUND TABLE 2

T-11 LAPTOP TABLE 1

T-12 SMALL MEETING TABLE 1

T-13 COMMUNITY TABLE 1

T-14 WORKTABLE 2

T-15 PRINTER TABLE 1

T-16 WORKTABLE 1

WB-1 WORK BENCH 25

WB-3 TOUCHDOWN STATION 3

X-1 LOCKER 12" x 12" 6

X-2 WHITEBOARD 4

X-3 WHITEBOARD 19

X-4 MOBILE WHITEBOARD 5

X-6 VEHICLE LIFT 1

1. SEE FURNITURE, FIXTURES, AND EQUIPMENT BINDER

FOR X-2 & X-3 WHITEBOARD SIZES.

REMARKS

10/22/21

FCC TEAM 2

FCC TEAM 1

BREAK AREA

FCC TEAM 3

FCC TEAM 4

WOMEN

MEN

MECHANICAL

EL-1

ELEVATOR

OPEN OFFICE

FCC LAB

STORAGE

IT/COMMS

FARADAY CAGE

O4 PRIVATE

OFFICE

CONFERENCE

ROOM

O4 PRIVATE

OFFICE

O4 PRIVATE

OFFICE

UPS

TR

FCC CUBES

CORRIDOR

S-1

STAIR 1

S-2

STAIR 2

X-3

ST-9

CH-1

D-1

(QTY. 7)

(QTY. 7)

CH-1

D-1

(QTY. 7)

(QTY. 7)

X-3

ST-9

X-2

ST-9

CH-1

D-1

(QTY. 7)

(QTY. 7)

X-3

ST-9

CH-1

D-1

(QTY. 7)

(QTY. 7)

D-1

CH-1

(QTY. 5)

(QTY. 5)

ST-3

(QTY. 5)

ST-8

D-1

CH-1

(QTY. 2)

(QTY. 2)

ST-4

(QTY. 20)

ST-4

(QTY. 17)

CH-1

WB-1

(QTY. 25)

(QTY. 25)

X-4X-3

(QTY. 2)

CH-2

T-4

(QTY. 2)

(QTY. 20)

CH-2

T-4

X-3

(QTY. 10)

CH-3

CH-2

D-3

(QTY. 2)

CH-3

CH-2

D-3

(QTY. 2)

X-2

T-13

CH-12

(QTY. 10)

CH-1

D-7

ST-12

ST-9

(QTY. 2)

(QTY. 2)

ST-11

T-15

T-16

CR-1

D-6

CH-1

COMSEC

X-2

O4 PRIVATE

OFFICE

D-3

CH-3

(QTY. 2)

D-3

CH-3

(QTY. 2)

CH-2 CH-2

D-1

CH-1

(QTY. 4)

(QTY. 4)

D-1

CH-1

(QTY. 2)

(QTY. 2)

ST-16

FC-1

1. SEE SHEETS IF201-IF203 FOR

DEMOUNTABLE WALL TYPES

GENERAL NOTES

J

O N

E S

F R

A N

K L

IN

R

D

S U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

4' 8' 16'

PROJECT

NORTH

TRUE

NORTH

B A

L T

IM

O

R E

D

IS

T R

IC

T

H

O P

K

IN

S P

L A

Z A

B A

L T

IM

O

R E

M A

R Y

L A

N D

F

IL

E N

A M

E

CONTROLLED UNCLASSIFIED INFORMATION

X X

X -X

X X

-X X

X

X X

X -X

X X

-X X

X

B

C

D

E

F

G

H

J

K

L

M

N

P

11 12 13 14 15 16 17 18 19 20

D R

A W

IN

G

N O

F

-2

-1

PROPERTY OF UNITED STATES GOVERNMENT, CONTROLLED UNCLASSIFIED INFORMATION (CUI), DISSEMINATION, AND DISTIBUTION TO AUTHORIZED INDIVIDUALS PROHIBITED

IF102

L E

V E

L

F U

R N

IT

U

R E

F

IX

T

U R

E S

A N

D E

Q U

IP

M

E N

T P

L A

N

H U

M P

H R

E Y

S E

N G

IN

E

E R

C E

N T

E R

A

L E

X A

N D

R

IA

V

IR

G

IN

IA

L B

A R

N A

R D

A V

E G

A

W B

Y N

U M

J C

A R

T E

R

O

C T

O B

E R

IF

.D

W G

B A

T T

A L

IO

N O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

P N

P

1/8" = 1'-0" C2

LEVEL 2 FURNITURE, FIXTURES AND EQUIPMENT PLAN

FURNITURE SCHEDULE

Type Mark Description Count

CH-1 DESK CHAIR 112

CH-2 EXECUTIVE CHAIR 21

CH-3 GUEST CHAIR 32

CH-4 TRAINING CHAIR 24

CH-5 SIDE CHAIR 16

CH-6 LOUNGE CHAIR 1

CH-7 SOFA 1

CH-8 LOUNGE CHAIR 2

CH-9 MODULAR SOFA 5

CH-10 ROCKER CHAIR 1

CH-11 BREAKROOM CHAIR 42

CH-12 BREAKROOM STOOL 10

CR-1 CREDENZA 54"W 3

CR-2 CREDENZA 42"W 1

D-1 WORKSTATION 65

D-2 EXECUTIVE WORKSTATION 1

D-3 PRIVATE OFFICE DESK 16

D-4 DESK 1

D-5 SERVICE COUNTER 1

D-6 DESK WITH RETURN 2

D-7 DESK 60"W 1

FC-1 FARADAY CAGE 1

ST-1 SHELVING 24X36 20

ST-2 STORAGE - PERSONAL CAGES 64

ST-3 SERVER RACKS 5

ST-4 STORAGE CASE WITH LOCK 67" H 18"W 37

ST-5 SHELVING 24X48 18

ST-6 SHELVING 24X42 12

ST-7 BOOKCASE 1

ST-8 STORAGE CABINET 3

ST-9 SAFE 5

ST-10 STORAGE CABINET WITH LOCK 3

ST-11 MOBILE PEDESTAL 4

ST-12 3H FILE CABINET 1

ST-13 LOCKER STORAGE 32

ST-14 DISPLAY CASE 3

ST-15 MEMORABILIA DISPLAY CASE 3

ST-16 BAKERS RACK 1

T-1 SMALL CONFERENCE TABLE 1

T-2 SIDE TABLE 1

T-3 BREAK ROOM TABLE 8

T-4 10-12 SEAT CONFERENCE TABLE 5

T-5 CLASSROOM TABLE 24"D 54"W 12

T-6 MEETING TABLE 1

T-7 COFFEE TABLE 1

T-8 SIDE TABLE 1

T-9 COFFEE TABLE 1

T-10 ROUND TABLE 2

T-11 LAPTOP TABLE 1

T-12 SMALL MEETING TABLE 1

T-13 COMMUNITY TABLE 1

T-14 WORKTABLE 2

T-15 PRINTER TABLE 1

T-16 WORKTABLE 1

WB-1 WORK BENCH 25

WB-3 TOUCHDOWN STATION 3

X-1 LOCKER 12" x 12" 6

X-2 WHITEBOARD 4

X-3 WHITEBOARD 19

X-4 MOBILE WHITEBOARD 5

X-6 VEHICLE LIFT 1

1. SEE FURNITURE, FIXTURES, AND EQUIPMENT BINDER

FOR X-2 & X-3 WHITEBOARD SIZES.

BREAK AREA

MEN

WOMEN

TR

MECHANICAL

EL-1

ELEVATOR

S4 CUBES

CLASSROOM

CG PRIVATE

OFFICE

TOILET

CG PRIVATE

OFFICE

CG

CONFERENCE

ROOM

CONFERENCE

ROOM

HHT PRIVATE

OFFICE

S3 PRIVATE

OFFICE

S3 PRIVATE

OFFICE

SPO PRIVATE

OFFICE

SPO PRIVATE

OFFICE

G4 PRIVATE

OFFICE

G4 PRIVATE

OFFICE

SCT SERVICE

AREA

OPEN OFFICE

AREA

CHAPLAIN

OFFICE

WAITING AREA

CG PRIVATE

OFFICE317

PSYCH OFFICE

CG PRIVATE

OFFICE

BBF

FF

CH-2T-4

D-2

T-5

CH-4

X-3

CH-1CH-1CH-1CH-1CH-1CH-1CH-1CH-1

D-1

CH-1 CH-1

D-1

CH-1 CH-1

D-1

D-1

CH-1 CH-1

D-1

CH-1 CH-1

D-1

D-1

CH-1 CH-1

D-1

CH-1 CH-1

D-1

D-1

CH-1 CH-1

D-1

CH-1 CH-1

D-1

EXTERIOR PATIO

S-1

STAIR 1

S-2

STAIR 2

CORRIDOR

T-3

(QTY. 16)(QTY. 4)

T-3

(QTY. 24)(QTY. 6)

(QTY. 12)

(QTY. 24)

CH-3

(QTY. 2)

D-3

CH-3

(QTY. 2)

D-3

CH-2

CH-2

CH-5

T-6

(QTY. 6)

CH-2

(QTY. 10)

T-4(QTY. 10)

CH-2

D-3

CH-3

(QTY. 2)

CH-2

D-3

CH-3

(QTY. 2)

CH-2

D-3

CH-3

(QTY. 2)

CH-2

D-3

CH-3

(QTY. 2)

CH-2

D-3

CH-3

(QTY. 2)

CH-2

D-3

CH-3

(QTY. 2)

CH-2

D-3

CH-3

(QTY. 2)

D-3

CH-2

CH-3 (QTY. 2)

D-3

CH-2

CH-3(QTY. 2)

D-3

CH-2

CH-3 (QTY. 2)

CH-6

T-7 T-8

CH-7

CH-9

CH-8

T-9

X-4

T-11

T-10

CH-9

(QTY. 2)

(QTY. 2)

CH-9CH-9

CH-9CH-9

X-3

X-3

X-3

CH-11

CH-11

CH-1

T-14T-14

D-5

ST-10

WB-3

(QTY. 3)

(QTY. 3) (QTY. 3)

ST-11

(QTY. 3)

D-1

CH-1

(QTY. 6)

(QTY. 2)

CR-2

CH-2

CR-1

ST-8

(QTY. 2)

ST-10

(QTY. 3)

(QTY. 2)

(QTY. 2)

ST-15

(QTY. 3)

1. SEE SHEETS IF201-IF203 FOR

DEMOUNTABLE WALL TYPES

GENERAL NOTES

J

O N

E S

F R

A N

K L

IN

R

D

S U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

4' 8' 16'

PROJECT

NORTH

TRUE

NORTH

B A

L T

IM

O

R E

D

IS

T R

IC

T

H

O P

K

IN

S P

L A

Z A

B A

L T

IM

O

R E

M A

R Y

L A

N D

F

IL

E N

A M

E

CONTROLLED UNCLASSIFIED INFORMATION

X X

X -X

X X

-X X

X

X X

X -X

X X

-X X

X

B

C

D

E

F

G

H

J

K

L

M

N

P

11 12 13 14 15 16 17 18 19 20

D R

A W

IN

G

N O

F

-2

-1

PROPERTY OF UNITED STATES GOVERNMENT, CONTROLLED UNCLASSIFIED INFORMATION (CUI), DISSEMINATION, AND DISTIBUTION TO AUTHORIZED INDIVIDUALS PROHIBITED

IF103

L E

V E

L

F U

R N

IT

U

R E

F

IX

T

U R

E S

A N

D E

Q U

IP

M

E N

T P

L A

N

H U

M P

H R

E Y

S E

N G

IN

E

E R

C E

N T

E R

A

L E

X A

N D

R

IA

V

IR

G

IN

IA

L B

A R

N A

R D

A V

E G

A

W B

Y N

U M

J C

A R

T E

R

O

C T

O B

E R

IF

.D

W G

B A

T T

A L

IO

N O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

P N

P

1/8" = 1'-0" C2

LEVEL 3 FURNITURE, FIXTURES AND EQUIPMENT PLAN

FURNITURE SCHEDULE

Type Mark Description Count

CH-1 DESK CHAIR 112

CH-2 EXECUTIVE CHAIR 21

CH-3 GUEST CHAIR 32

CH-4 TRAINING CHAIR 24

CH-5 SIDE CHAIR 16

CH-6 LOUNGE CHAIR 1

CH-7 SOFA 1

CH-8 LOUNGE CHAIR 2

CH-9 MODULAR SOFA 5

CH-10 ROCKER CHAIR 1

CH-11 BREAKROOM CHAIR 42

CH-12 BREAKROOM STOOL 10

CR-1 CREDENZA 54"W 3

CR-2 CREDENZA 42"W 1

D-1 WORKSTATION 65

D-2 EXECUTIVE WORKSTATION 1

D-3 PRIVATE OFFICE DESK 16

D-4 DESK 1

D-5 SERVICE COUNTER 1

D-6 DESK WITH RETURN 2

D-7 DESK 60"W 1

FC-1 FARADAY CAGE 1

ST-1 SHELVING 24X36 20

ST-2 STORAGE - PERSONAL CAGES 64

ST-3 SERVER RACKS 5

ST-4 STORAGE CASE WITH LOCK 67" H 18"W 37

ST-5 SHELVING 24X48 18

ST-6 SHELVING 24X42 12

ST-7 BOOKCASE 1

ST-8 STORAGE CABINET 3

ST-9 SAFE 5

ST-10 STORAGE CABINET WITH LOCK 3

ST-11 MOBILE PEDESTAL 4

ST-12 3H FILE CABINET 1

ST-13 LOCKER STORAGE 32

ST-14 DISPLAY CASE 3

ST-15 MEMORABILIA DISPLAY CASE 3

ST-16 BAKERS RACK 1

T-1 SMALL CONFERENCE TABLE 1

T-2 SIDE TABLE 1

T-3 BREAK ROOM TABLE 8

T-4 10-12 SEAT CONFERENCE TABLE 5

T-5 CLASSROOM TABLE 24"D 54"W 12

T-6 MEETING TABLE 1

T-7 COFFEE TABLE 1

T-8 SIDE TABLE 1

T-9 COFFEE TABLE 1

T-10 ROUND TABLE 2

T-11 LAPTOP TABLE 1

T-12 SMALL MEETING TABLE 1

T-13 COMMUNITY TABLE 1

T-14 WORKTABLE 2

T-15 PRINTER TABLE 1

T-16 WORKTABLE 1

WB-1 WORK BENCH 25

WB-3 TOUCHDOWN STATION 3

X-1 LOCKER 12" x 12" 6

X-2 WHITEBOARD 4

X-3 WHITEBOARD 19

X-4 MOBILE WHITEBOARD 5

X-6 VEHICLE LIFT 1

1. SEE FURNITURE, FIXTURES, AND EQUIPMENT BINDER

FOR X-2 & X-3 WHITEBOARD SIZES.

DIVIDER 4

GSB (STE) 3 BAY

GARAGE

GSB FCC

LOGISTICS AREA

& SECURE

LOADOUT

LOADOUT

GSB FCC

MISSION

SUPPORT

DMARC

FCO TEAM CAGE

GSB MISSION

TEAM CAGE

FCO TEAM CAGE

FCO TEAM CAGE

EL-1

ELEVATOR

ENTRY

VESTIBULE

CORRIDOR

COLLATERAL

FIRE

ELECTRICAL

CONFERENCE

MEETING AREA

PERSONAL

CAGES

S-1

STAIR 1

CORRIDOR

WELLNESS

JC

CORRIDOR

S4 STORAGE

STORAGE

BBF

FF 2DR

MEN

WOMEN

CORRIDOR

S-2

STAIR 2

SALLY PORT

CORRIDOR

RECEPTION

AREA115

ELEVATOR

LOBBY

CORRIDOR

MECHANICAL

TR

FCO TEAM CAGE

J

O N

E S

F R

A N

K L

IN

R

D

S U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

4' 8' 16'

PROJECT

NORTH

TRUE

NORTH

B A

L T

IM

O

R E

D

IS

T R

IC

T

H

O P

K

IN

S P

L A

Z A

B A

L T

IM

O

R E

M A

R Y

L A

N D

F

IL

E N

A M

E

CONTROLLED UNCLASSIFIED INFORMATION

X X

X -X

X X

-X X

X

X X

X -X

X X

-X X

X

B

C

D

E

F

G

H

J

K

L

M

N

P

11 12 13 14 15 16 17 18 19 20

D R

A W

IN

G

N O

F

-2

-1

PROPERTY OF UNITED STATES GOVERNMENT, CONTROLLED UNCLASSIFIED INFORMATION (CUI), DISSEMINATION, AND DISTIBUTION TO AUTHORIZED INDIVIDUALS PROHIBITED

IF201

L E

V E

L

D E

M O

U N

T A

B L E

W A

L L S

P L A

N

H U

M P

H R

E Y

S E

N G

IN

E

E R

C E

N T

E R

A

L E

X A

N D

R

IA

V

IR

G

IN

IA

L B

A R

N A

R D

A V

E G

A

W B

Y N

U M

J C

A R

T E

R

O

C T

O B

E R

IF

.D

W G

B A

T T

A L

IO

N O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

P N

P

1/8" = 1'-0" C2

LEVEL 1 DEMOUNTABLE WALLS PLAN

T

T

T

T

T

T

T

T

T

T

C

TT

T

J

EQ T

T

VS

EQ

EQ

EQ

T

O S

ESS

D

DD

TV

D D

3D3

D D

D D

VS

TV

T V

VS VS

D

T

EQT

TV

FCC TEAM 2

FCC TEAM 1

BREAK AREA

FCC TEAM 3

FCC TEAM 4

WOMEN

MEN

MECHANICAL

EL-1

ELEVATOR

OPEN OFFICE

FCC LAB

STORAGE

IT/COMMS

FARADAY CAGE

O4 PRIVATE

OFFICE

CONFERENCE

ROOM

O4 PRIVATE

OFFICE

O4 PRIVATE

OFFICE

UPS

TR

FCC CUBES

CORRIDOR

S-1

STAIR 1

S-2

STAIR 2 X-8

X-9

X-8X-7

X-8

X-7

X-5

X-10

X-8

X-7

X-9

X-9 X-7

X-7

COMSEC

O4 PRIVATE

OFFICE

X-5

X-8

X-8

WALL TYPE LEGEND

• SEE SPECIFICATIONS FOR

DEMOUNTABLE WALLS IN FF&E

PACKAGE FOR FURTHER DETAILS

LAMINATE EXTERIOR AND

INTERIOR W/ GLASS

X-5

LAMINATE EXTERIOR W/

FABRIC INTERIOR

X-7

FABRIC EXTERIOR AND

INTERIOR

X-8

LAMINATE EXTERIOR,

FABRIC INTERIOR W/ GLASS

X-9

LAMINATE EXTERIOR AND

INTERIOR

X-10

1. SEE SHEETS E-001 - E-002 FOR

ELECTRICAL ABBRVIATIONS AND

SYMBOL LEGENDS.

2. REFER TO SHEET IF400 FOR

DEMOUNTABLE WALL TYPE

ELEVATIONS.

GENERAL NOTES

J

O N

E S

F R

A N

K L

IN

R

D

S U

IT

E

R A

L E

IG

H

N

C

-3

(9

-6

(9

-7

F

A X

L

IC

E N

S E

F

-0

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

1 2 3 4 5 6 7 8 9 10

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

4' 8' 16'

PROJECT

NORTH

TRUE

NORTH

B A

L T

IM

O

R E

D

IS

T R

IC

T

H

O P

K

IN

S P

L A

Z A

B A

L T

IM

O

R E

M A

R Y

L A

N D

F

IL

E N

A M

E

CONTROLLED UNCLASSIFIED INFORMATION

X X

X -X

X X

-X X

X

X X

X -X

X X

-X X

X

B

C

D

E

F

G

H

J

K

L

M

N

P

11 12 13 14 15 16 17 18 19 20

D R

A W

IN

G

N O

F

-2

-1

PROPERTY OF UNITED STATES GOVERNMENT, CONTROLLED UNCLASSIFIED INFORMATION (CUI), DISSEMINATION, AND DISTIBUTION TO AUTHORIZED INDIVIDUALS PROHIBITED

IF202

L E

V E

L

D E

M O

U N

T A

B L E

W A

L L S

P L A

N

H U

M P

H R

E Y

S E

N G

IN

E

E R

C E

N T

E R

A

L E

X A

N D

R

IA

V

IR

G

IN

IA

L B

A R

N A

R D

A V

E G

A

W B

Y N

U M

J C

A R

T E

R

O

C T

O B

E R

IF

.D

W G

B A

T T

A L

IO

N O

P E

R A

T

IO

N S

F A

C

IL

IT

Y

P N

P

1/8" = 1'-0" C2

LEVEL 2 DEMOUNTABLE WALLS PLAN

TTT

T

T

T

TTT

T T

T

C

CC

OS

D

D

D

EQ

VSVSVSVSVS

V S

EQ

EQ

EQ

EQ

V S

V S

T

TV

TV

T V

T V

TVTV

D

3D

D

D

D

ESS

T V

T V

T V

T V

VSVS

V S

V S

3D3D

J

D

EQ

T V

T V

BREAK AREA

MEN

WOMEN

TR

MECHANICAL

EL-1

ELEVATOR

S4 CUBES

CLASSROOM

CG PRIVATE

OFFICE

TOILET

CG PRIVATE

OFFICE

CG

CONFERENCE

ROOM

CONFERENCE

ROOM

HHT PRIVATE

OFFICE

S3 PRIVATE

OFFICE

S3 PRIVATE

OFFICE

SPO PRIVATE

OFFICE

SPO PRIVATE

OFFICE

G4 PRIVATE

OFFICE

G4 PRIVATE

OFFICE

SCT SERVICE

AREA

OPEN OFFICE

AREA

CHAPLAIN

OFFICE

WAITING AREA

CG PRIVATE

OFFICE317

PSYCH OFFICE

CG PRIVATE

OFFICE

BBF

FF

EXTERIOR PATIO

S-1

STAIR 1

S-2

STAIR 2

CORRIDOR

X-7

X-7

X-7

X-7 X-7

X-5

X-7 X-7

X-5

X-10

X-5

X-5

X-7

X-10 X-5

X-8

WALL TYPE LEGEND

• SEE SPECIFICATIONS FOR

DEMOUNTABLE WALLS IN FF&E

PACKAGE FOR FURTHER DETAILS

LAMINATE EXTERIOR AND

INTERIOR W/ GLASS

X-5

LAMINATE EXTERIOR W/

FABRIC INTERIOR

X-7

FABRIC EXTERIOR AND

INTERIOR

X-8

LAMINATE EXTERIOR,

FABRIC INTERIOR W/ GLASS

X-9

LAMINATE EXTERIOR AND

INTERIOR

X-10

1. SEE SHEETS E-001 - E-002 FOR

ELECTRICAL ABBRVIATIONS AND

SYMBOL LEGENDS.

2. REFER TO SHEET IF400 FOR

DEMOUNTABLE WALL TYPE

ELEVATIONS.

GE…

This is the start of the file's text. The full file is on GovTribe.