Attachment J5 - Asbestos Rpt-Break Room.pdf
PDF 880 KB Posted
- Solicitation number
- 75F40121R00014
About this file
This document contains an asbestos analysis report and related federal contract opportunity for roof replacement. The asbestos analysis report details testing conducted on samples from the break room and maintenance room of Building 53, Section A at the National Center for Toxicological Research facility in Jefferson, Arkansas. Two of the five samples from the break room contained chrysotile asbestos at 10% and amosite asbestos at 3-4%. The remaining samples and both samples from the maintenance room did not contain detectable asbestos.
The related federal contract opportunity is a solicitation from the Department of Health and Human Services Food and Drug Administration Office of Acquisition and Grant Services to replace roofs on Buildings 15 and 53 A, B, C, D and the mechanical room at the National Center for Toxicological Research facility in Jefferson, Arkansas. The solicitation seeks roof repair and replacement services at this location but provides no further details on response dates, award amounts, or other contractual terms.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
220 North Knoxville Russellville, Arkansas 72801
Phone (479) 968-6767 Fax (479) 968-1956 www.eegonline.com
Environmental Enterprise Group (EEG), Inc. has completed the analysis of the sample submitted to our laboratory on August 05, 2020, from the above-referenced project.
The method of analysis utilized follows the U.S. EPA 600/R-93/116 Interim Method for the Determination of
Asbestos Bulk Insulation Samples. Quantification is based upon visual estimation of the amounts of material present utilizing Polarized Light Microscopy. It may be found that additional techniques are needed to attain a positive identification of asbestos and a reliable accuracy for the quantity of asbestos in a sample; therefore, EEG appended their Polarized Light Microscopy analysis with the following footnote.
Analysis of floor tile and other resinously bound materials by Polarized Light Microscopy (PLM) may yield false negative results because of method limitations in separating closely bound fibers in detecting fibers of small length and diameter. When analysis of such materials by the PLM Method yields negative results for the presence of asbestos, Environmental Enterprise Group (EEG), Inc. recommends utilizing alternative methods of identification including Transmission Electron Microscopy.
These samples can be resubmitted at your discretion. Samples will be disposed of within 30 days unless otherwise notified in writing by the client.
If you have any questions regarding your report, please contact me at (800) 530-7968 or (479) 968-6767.
Analytical Results Submitted By:
August 05, 2020
RE:
Dear Matthew Milner
Asbestos Analysis
Matthew Milner
National Center for Toxicological Research
3900 NCTR Road
Jefferson, AR 72079
Mike Cole
Laboratory Director
National Center for Toxicological Research
Asbestos Analysis
00025-B2020-0354
08/05/2020
Client:
Client Project:
Job Number:
Date Reported:
EPA-600/R-93/116METHOD:
Client Sample
ID Layer Color Sample Description
ASBESTOS
Asbestos Report Summary
By: POLARIZED LIGHT MICROSCOPY
Building 53 Section ALocation:
53A Break
Room Sample 1
NA White Bldg. 53, Section A Break
Room
10% Chrysotile AsbestosTSI
53A Break
Room Sample 1
NA White Bldg. 53, Section A Break
Room
4% Amosite AsbestosTSI
53A Break
Room Sample 2
NA White Bldg. 53, Section A Break
Room
10% Chrysotile AsbestosTSI
53A Break
Room Sample 2
NA White Bldg. 53, Section A Break
Room
3% Amosite AsbestosTSI
53A Break
Room Sample 3
NA Yellow Bldg. 53, Section A Break
Room
None DetectedTSI
53A Break
Room Sample 4
NA Yellow Bldg. 53, Section A Break
Room
None DetectedTSI
53A Break
Room Sample 5
NA Yellow Bldg. 53, Section A Break
Room
None DetectedTSI
53A Maint.
Room Sample 1
NA Yellow Bldg. 53, Section A Break
Room
None DetectedTSI
53A Maint.
Room Sample 2
NA Yellow Bldg. 53, Section A Break
Room
None DetectedTSI
NVLAP Code: 101587-0 Page 1 of 1 www.eegonline.com
National Center for Toxicological Research
Asbestos Analysis
EPA-600/R-93/116
Building 53 Section A
8/5/2020 FedEx
00025-B2020-0354
Matthew Milner
7/28/2020
8/5/2020
Client:
Client Project:
Methodology:
Sample(s) Taken From:
Received: Shipped Via:
Job Number:
Sampled By:
Date Sampled:
Reported:
Bulk Asbestos Report
Sample # Client Sample ID:
53A Break
Room Sample 1
Layered Analysis
No Positive
Sample Description: White
Bldg. 53, Section A Break Room
This material contains approximately
Chrysotile Asbestos 10% Amosite Asbestos 4%
Quartz 1% Gypsum Mortar 70%
Particulate Matter 15%
TSI
Sample # Client Sample ID:
53A Break
Room Sample 2
Layered Analysis
No Positive
Sample Description: White
Bldg. 53, Section A Break Room
This material contains approximately
Chrysotile Asbestos 10% Amosite Asbestos 3%
Quartz 2% Gypsum Mortar 70%
Particulate Matter 15%
TSI
Sample # Client Sample ID:
53A Break
Room Sample 3
Layered Analysis
No None Detected
Sample Description: Yellow
Bldg. 53, Section A Break Room
This material contains approximately
Cellulose <1% Fiberglass 97%
Particulate Matter 3%
TSI
Sample # Client Sample ID:
53A Break
Room Sample 4
Layered Analysis
No None Detected
Sample Description: Yellow
Bldg. 53, Section A Break Room
This material contains approximately
Fiberglass 98% Particulate Matter 2%
TSI
Respectfully Submitted, EEG, Inc
Analyst
NVLAP Signatory
Current information listed above applies to the standards or procedures identified and the samples actually tested. The methodology(s) listed in this report is the only methodology(s) used. The methodology listed in this report is a deviation from NVLAP's specific scope of accreditation
(EPA-600/M-4-82-020 method). Each percentage reported above is a visual estimation of total composition, unless otherwise noted in this report.
Asbestos detection limit is less than 1 percent. Test measurements are traceable to Standard Reference Material 1866a and 1867. The results are valid only for the materials tested. The information listed above is for the exclusive use of the client listed above. Sample results shall not be reproduced in any form or fashion for advertising or other purposes in connection with EEG's name or signature without consent from EEG. Sample results shall not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. Samples not consumed in analysis will be retained for a maximum of 30 days. Samples may be returned to the client upon request. Accredited by the National Voluntary Laboratory
Accreditation Program for the specific scope of Accreditation under NVLAP code 101587-0.
www.eegonline.com
National Center for Toxicological Research
Asbestos Analysis
EPA-600/R-93/116
Building 53 Section A
8/5/2020 FedEx
00025-B2020-0354
Matthew Milner
7/28/2020
8/5/2020
Client:
Client Project:
Methodology:
Sample(s) Taken From:
Received: Shipped Via:
Job Number:
Sampled By:
Date Sampled:
Reported:
Bulk Asbestos Report
Sample # Client Sample ID:
53A Break
Room Sample 5
Layered Analysis
No None Detected
Sample Description: Yellow
Bldg. 53, Section A Break Room
This material contains approximately
Cellulose <1% Fiberglass 98%
Particulate Matter 2%
TSI
Sample # Client Sample ID:
53A Maint.
Room Sample 1
Layered Analysis
No None Detected
Sample Description: Yellow
Bldg. 53, Section A Break Room
This material contains approximately
Cellulose <1% Fiberglass 98%
Particulate Matter 2%
TSI
Sample # Client Sample ID:
53A Maint.
Room Sample 2
Layered Analysis
No None Detected
Sample Description: Yellow
Bldg. 53, Section A Break Room
This material contains approximately
Fiberglass 98% Particulate Matter 2%
TSI
Respectfully Submitted, EEG, Inc
Analyst
NVLAP Signatory
Current information listed above applies to the standards or procedures identified and the samples actually tested. The methodology(s) listed in this report is the only methodology(s) used. The methodology listed in this report is a deviation from NVLAP's specific scope of accreditation
(EPA-600/M-4-82-020 method). Each percentage reported above is a visual estimation of total composition, unless otherwise noted in this report.
Asbestos detection limit is less than 1 percent. Test measurements are traceable to Standard Reference Material 1866a and 1867. The results are valid only for the materials tested. The information listed above is for the exclusive use of the client listed above. Sample results shall not be reproduced in any form or fashion for advertising or other purposes in connection with EEG's name or signature without consent from EEG. Sample results shall not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. Samples not consumed in analysis will be retained for a maximum of 30 days. Samples may be returned to the client upon request. Accredited by the National Voluntary Laboratory
Accreditation Program for the specific scope of Accreditation under NVLAP code 101587-0.