This attachment is a design analysis for a roof replacement project at a federal facility. The solicitation requests bids to replace roofs on five buildings totaling approximately 135,000 square feet at the National Center for Toxicological Research campus in Jefferson, Arkansas. The work includes removal of existing roof systems down to decking and installation of new mechanically attached single-ply thermoplastic polyolefin (TPO) membrane roofing system, insulation, cover board, drains, accessories and 20-year warranty. Bids are due by February 11th, 2022 with an anticipated award date of March 4th. The solicitation is issued by the Department of Health and Human Services Food and Drug Administration Office of Acquisition and Grant Services.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUILDING 15, 53A, 53B & Mechanical Room, Roof Replacement & Interior Renovations

BUILDING 53

3900 NCTR ROAD

JEFFERSON, AR 72079

ORDER NO. HHSF223201610018I

REQUISITION REF NO. 1224480

DESIGN ANALYSIS

PREPARED FOR:

ADMIN OFFICE:

FDA/OO/OFBA/OAGS/DAP

OAGS – FIELD OPERATIONS BRANCH

PREPARED BY:

WER ARCHITECTS

MARCH 17, 2021

PROPERTY OF THE UNITED STATES GOVERNMENT. COPYING,

DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS, PLANS, OR

SPECIFICATIONS TO UNAUTHORIZED PERSONS IS PROHIBITED.

PLEASE RECYCLE

Design Analysis

FDA / OO / OFBA / OAGS / DAP 03/17/2021

TABLE OF CONTENTS

I. Executive Summary

a. Introduction / Project scope

b. Project team

II. Design Analysis Narratives

a. Architectural / Interiors Design Analysis

b. Mechanical Design Analysis

c. Electrical Design Analysis

Appendices

Appendix A – Architectural Cut Sheets

Appendix B – Roof System Cut Sheets

Appendix C – Asbestos Roof Survey

Appendix D – Mechanical Equipment Cut Sheets

Appendix E – Plumbing Equipment Cut Sheets

Appendix F – Lighting Fixture / Elec Equipment Cut Sheets

I. EXECUTIVE SUMMARY

a. Introduction / Project Scope

The design team has been tasked to prepare a final design for Building 15, 53A, 53B and

Mechanical Room, including Roof Replacement and Interior Renovations. The design team is to prepare plans, specifications, design analysis and cost estimates to be issued to contractors for bidding and construction.

This task order is for Building 53A and 53B only, which houses animal rooms, research labs and mechanical and electrical equipment. The existing roof system of Building 53 and the mechanical room has reached its useful life and requires a new roofing system. This portion of the facility (53A & 53B) is primarily two-story, with one story near the east end. 53A &

53B is approximately 30,546 square feet. Building 15 Roof Replacement is also included in the project. The remainder of Building 53 (53C and 53D) is scheduled to receive a new roof following this submission. For economy of construction, it would be advantageous if 53A, B, C & D could be issued as a single roofing project. However, funding might require separate packages to be issued. The design team will prepare drawing packages as dictated by FDA.

The roof replacement for 53E will be issued with the interior renovation of 53E.

b. Project Team

Engineering

CROMWELL Architects/Engineers | 1300 East 6th Street | Little Rock, AR 72202

Rob Seay – Project Manager

Corey Imhoff PE – Mechanical Engineer

Allan Fuller – Electrical Engineer

Weston Lummus PE – Fire Protection

Architecture & Interiors

WER Architects | 901 West Third St. | Little Rock, AR 72201

John Greer Jr AIA – Managing Principal

Ross Piazza AIA – Project Manager

Client / Tenant

Jefferson Labs | 3900 NCTR Road | Jefferson, AR 72079

Viplav Patel – Contracting Officers Representative

II. DESIGN ANALYSIS NARRATIVES

a. ARCHITECTURAL / INTERIORS DESIGN ANALYSIS

EXTERIOR

Building 53 is located on the northeast part of the NCTR Campus and is approximately 532’ x 135’, rectangle in shape for the most part. This overall length includes Building 15 which adjoins Building 53 on the east side. Building 15 Roof

Replacement is included in this project.

Building 53A is two stories except for one portion at its east end. Building 53B is two stories. Building 15 is one story. There is no exterior work in the scope of work except for the roof replacement.

INTERIOR

The interior work includes a renovation of the existing Break Room at the northeast corner of the first floor. Floor and ceiling finishes in the space will be new. Walls and existing hollow metal doors and frames are to be painted. Existing base and wall cabinets will be replaced. Appliances and lockers will be relocated within the space. The north and south stair wells at Building 53A are scheduled for new paint and replacement of acoustical panels; hollow metal doors and frames will be painted. Two pairs of doors are scheduled to be replaced - one set will receive an automatic door operator. No doors will receive new card access.

Breakroom 100:

• Floor: 12” x 12” VCT 4”

• Base: 4” rubber

• Ceiling: Tegular 2’x2’ Lay-In Ceiling

• Wall Finish: Painted Gyp. Bd with (1) Accent Paint Wall

North and South Stair Wells:

• Floor: Existing VCT to remain

• Base: Existing rubber base to remain

• Stair Treads: Existing rubber treads to remain

• Ceiling: Existing plaster to be painted.

• Wall Finish: Painted Gyp. Bd and/or plaster

• End Walls: Acoustical panels and supporting frame to be replaced.

Mechanical Room:

• Floor: Existing sealed concrete to remain

• Base: Existing to remain

• Ceiling in Mechanical Room: Exposed Structure

• Ceiling in Elevator Room (northwest corner of mechanical room): New 2 x 4 suspended ceiling and grid

• Wall Finish: Painted (Entire west wall due to infill of door opening, no paint

• at other walls)

ROOF REPLACEMENT AT BUILDINGS 53A & 53B

53A and 53B roof replacement is 30,546 square feet. The existing composition of the roof, from top to bottom, is as follows:

• Existing modified bitumen roof membrane

• Existing lightweight insulating concrete deck

• Existing EPS board

• Existing pitch and gravel roof

• Existing gypsum deck

This project proposes to tear off the existing modified bitumen roof system down to the existing lightweight insulating concrete deck and replace with a new modified bitumen roof system described below, from top to bottom:

• P30FR granulated cap sheet adhered with PA311M adhesive

• P20FR base sheet adhered with PA311M adhesive

• PARABASE FS nailable base sheet attached with light weight two-part fasteners

• Existing light weight insulating concrete deck to remain

The Basis of Design is Siplast, Inc. Other acceptable manufacturers are listed in the specification. The slope is built into the existing roof deck and is adequate.

Flashing conditions which cannot achieve an 8” minimum height will be flashed with PARAPRO Flashing Resin, a monolithic, reinforced flashing membrane.

Because of the amount of existing rooftop equipment – air handlers, piping, exhaust fans, exhaust flues, VTRs, piping, duct penetrations, etc. – it was decided to forego new insulation over the concrete deck. Additional thickness would create flashing problems resulting in a significant cost increase.

Additional platform grates and removable handrails, where missing, have been scheduled around rooftop air handlers at Building 53 and Building 14.

ROOF REPLACEMENT AT BUILDING 15

Building 15 roof replacement is 9,857 square feet including the entry roof. There are 4 existing roof drains, plus 1 at the entry roof. The existing composition of the main roof, from top to bottom, is as follows:

• Existing modified bitumen roof membrane

• Existing perlite cover board

• Existing insulation at main roof (no insulation at entry roof)

• Existing steel deck (at most places, including entry roof)

• Existing lightweight concrete (at some places in main roof)

This project proposes to tear off the existing modified bitumen roof system down to the existing deck and replace with a new modified bitumen roof system described below, from top to bottom:

• P30FR granulated cap sheet adhered with PA311R adhesive

• P20FR base sheet adhered with PA311R adhesive

• ½” Densdeck prime roof coverboard with foamable adhesive over insulation

• Poly iso tapered insulation (1 ½” start thickness at roof drains)

• Existing steel or light weight concrete deck to remain

The Basis of Design is Siplast, Inc. Other acceptable manufacturers are listed in the specification. Slope will be from the perimeter edge down toward the interior roof drains, achieved with tapered insulation.

b. MECHANICAL DESIGN ANALYSIS

53A BREAK ROOM

1. The current break room is served by two 4-pipe fan-coil units. One unit is a horizontal concealed unit located above the ceiling and the other is a horizontal cabinet located at the ceiling level in the space. Both units will be removed and all existing piping, ductwork, and air devices will be removed and/or capped. There is also an existing supply air grille that is supplied by a

VAV box from the adjacent space. This grille will be removed and the ductwork capped.

2. A new cassette style ductless split system will provide cooling and heating to the break room. The condensing unit will be located on the ground outside the room.

3. The existing two compartment sink will be replaced. I water line will be added to serve the new refrigerator ice maker.

NORTH AND SOUTH STAIRWELLS

1. Both stairwells are currently unconditioned. Each stairwell will be cooled and heated with a wall mounted ductless split system. Condensing units shall be located on the roof.

53 MECHANICAL ROOM

1. The mechanical room has several existing exhaust fans and ventilators that are no longer used. This unused equipment will be removed.

2. There are two existing exhaust fans and two ventilators that serve the refrigeration monitoring system. These units will be replaced. The controls will be adjusted to allow the fans to run at a lower speed during normal operation to provide ventilation in the mechanical room. When an alarm is triggered by the refrigeration monitor, the fans will run at high speed to meet

ASHRAE 15 requirements.

3. According to Trane, the largest chiller has 1,650lbs of refrigerant.

CFM = 100(1,650)^1/2 = 4,062 CFM

The existing fans and ductwork were sized at 4,100 CFM each. Each fan is ducted down to the floor next to each chiller. In the event of a refrigerant leak, we recommend to run both fans to get adequate ventilation at both chillers. This would provide 8,200 CFM, which exceeds ASHRAE 15 while also assuring good ventilation regardless of which chiller has the leak.

53 ELEVATOR SHAFT

1. The current elevator shaft is ventilated by a non-powered ventilator. This ventilator will be removed and not replaced. The current building code does not require elevator shafts under three stories to be ventilated.

53B ROOF

1. The roof has an existing exhaust fan and ventilator that are no longer used.

This unused equipment will be removed.

2. The existing exhaust fan (EF-61) and intake ventilator (IV-61) will be replaced.

CONTROLS

1. All new exhaust fans will be controlled/monitored by the existing BAS.

2. The new ductless split systems will be controlled by a wall mounted thermostat.

c. ELECTRICAL DESIGN ANALYSIS

53A BREAK ROOM

1. The existing fan coil will be disconnected and taken out. The new split system will be powered from nearby panel A.

2. The existing wire way / receptacle runs located above the counter tops on both sides of the room will be removed and replaced with a new surface mount wire way with GFI receptacles mounted every 2’. The wire way(s) will be powered from existing panel A.

3. The existing disposer will be removed and the new disposer will be powered from the same circuit with new switch.

4. The existing 2 x 4 fluorescent fixtures will be removed and replaced with new

LED 2 x 4 light fixtures using the same circuits.

NORTH AND SOUTH STAIRWELLS

1. Both stairwells will be provided with new split type HVAC systems powered from 2nd floor nearby panels D and H in 2nd floor utility corridor 53A-239. Both panels have ample spare capacity.

2. Existing fluorescent fixtures will be removed in both stairwells and replaced with new LED occupancy sensor hi/lo types with emergency battery backups at all landing levels.

53 ROOF EQUIPMENT

1. Several fans and ventilators will be removed completely. The conduits and conductors will be removed to the respective panels.

2. Several fans and ventilators will be replaced with new. The existing circuit(s) will be re-used to power the new equipment.

APPENDIX A

(Architectural Cut Sheets)

TechLine 877 276-7876 armstrongceilings.com/tectum armstrongceilings.com/capabilities See more photos at:

armstrongceilings.com/photogallery to do more plus capabilities

TECTUM® Direct-Attach Ceiling & Wall Panels coarse texture

Tectum® Direct-Attach ceiling panels in White

Tectum® Direct-Attach ceiling and wall panels provide durable, sustainable, acoustical options for a wide variety of applications.

TYPICAL APPLICATIONS

• Gymnasiums

• Auditoriums

• Multi-purpose Spaces

• Exposed Structures

• Acoustical Retrofits

• Education Spaces

• Covered Exterior Applications*

(1-1/2" and 2" thick panels only)

• Indoor Swimming Pools*

(1-1/2" and 2" thick panels only)

* Must maintain 1" air gap behind panel

KEY SELECTION ATTRIBUTES

• Now you can install 1" thick Tectum® on Trusses and I-Beams for added acoustics while maintaining an exposed structure visual on the deck

• Tectum panels are Living Product Imperative Certified by the International Living Future Institute – 1" panels in White and Natural only

• Tectum panels are part of the Sustain® portfolio and meet the most stringent sustainability compliance standards today – 1" panels in White and Natural only

• Now, long edges beveled, short edges beveled available as a standard option

• Great retrofit solution for noise reduction

• Excellent noise absorption – NRC up to 0.85 (1" panel, C-40 Mounting)

• USDA Certified Biobased Product, 98%

• Can be field painted up to 6 times without impacting acoustic or fire performance

Horizontal Line-Design Panel

Diagonal Right Line-Design Panel

Diagonal Left Line-Design Panel

Grid Line-Design Panel

Diamond Line-Design Panel

Vertical Line-Design Panel

Diagonal Right Line-Design Panel

Diagonal Left Line-Design Panel

Horizontal Line-Design Panel

Diamond Line-Design Panel

Vertical Line-Design Panel

Grid Line-Design Panel

Horizontal Line-Design Panel

Diagonal Right Line-Design Panel

Diagonal Left Line-Design Panel

Grid Line-Design Panel

Diamond Line-Design Panel

Vertical Line-Design Panel

Horizontal Line-Design Panel

Diagonal Right Line-Design Panel

Diagonal Left Line-Design Panel

Grid Line-Design Panel

Diamond Line-Design Panel

Vertical Line-Design Panel

Horizontal Line-Design Panel

Diagonal Right Line-Design Panel

Diagonal Left Line-Design Panel

Grid Line-Design Panel

Diamond Line-Design Panel

Vertical Line-Design Panel

Horizontal Line-Design Panel

Diagonal Right Line-Design Panel

Diagonal Left Line-Design Panel

Grid Line-Design Panel

Diamond Line-Design Panel

Vertical Line-Design Panel

Horizontal Line-Design Panel

Diagonal Right Line-Design Panel

Diagonal Left Line-Design Panel

Grid Line-Design Panel

Diamond Line-Design Panel

Vertical Line-Design Panel

LINE DESIGN CAPABILITIES

Max panel size for line designs is 2' x 4'. Custom line designs available.

Contact Architectural Specialties for more information.

DETAILS

1. Tectum® Direct-Attach Panel in White

2. Tectum® Direct-Attach Panels in White

NOTE: Standard panel edges are unfinished.

Painted panel edges available through special order.

Custom color panel edges are fully painted. 1

CAD/Revit® drawings at:

armstrongceilings.com

1X Furring Strips 24" O.C.

Or Equal

Tectum® Direct-Attach Panel

Laid On 3/4" Furring Strips new new

White

(TWH)

Natural

(TNA)

COLORS Due to printing limitations, shade may vary from actual product.

Custom Colors Available

High Performance Sustainable

Ceiling Systems

• Variety of made-to-order color options available

• Can be mechanically fastened to a wide variety of surfaces including masonry, drywall, wood, trusses, I-Beams, and more

D

IREC

T-TO

-D

EC

K – C

EILIN

G

S & W

A

LLS

LOCATION DEPENDENT

LE

ED

en er gy m an ag em en t re cy cl ab le ex te nd ed pr od uc er r es p.

bi ob as at er ia ls re gi on al er ia ls de si gn fo r fle xi bi lit y co ns tr uc tio n w as te m gm t

EP

D

For LEED contribution visit armstrongceilings.com/greengenie m at er ia l in gr ed ie nt re po rt in g re cy c l co en t so ur ci ng o f ra w m at er ia ls lo w e m it tin g/ er ia ls lig ht in g qu it y

FS

C

(f or w oo d) ac ou st ic s

RECYCLED

CONTENT92%

TechLine 877 276 7876 armstrongceilings.com/walls

ACOUSTICAL INFORMATION

Pa ne l Th ic kn es s

M ou nt

M et ho d

1" 0.40 0.45 0.80

0.85

A D-20 C-20

C-40

1-1/2" 0.55 0.60 0.90

0.95

A

2" 0.60 0.70 0.95

1.00

A

Edge Profile

Item No. ◆

Dimensions Nominal W x L x H (Inches)

Fi

Ra g

Li gh t Re fle ct M ol d

M ild ew

Pr ot ec tio n

Sa g

Re si st

Ce rt ifi ed

L ow

VO

C Em is si on s

Im pa ct

Sc ra tc h

-Y r W ar ra nt y

TECTUM® Direct-Attach Ceiling & Wall Panels (FSC® Certified)

(White Only)

BioBlock Humi- Guard+

Durability

Long Edges Beveled/ Short Edges Square

8182T10_ _ _ 23-3/4 x 48 x 1" Class A Up to 0.75 • • • • • •

8181T10_ _ _ 23-3/4 x 96 x 1" Class A Up to 0.75 • • • • • •

8180T10_ _ _ 47-3/4 x 96 x 1" Class A Up to 0.75 • • • • • •

Long Edges Beveled/ Short Edges Beveled*

8175T10_ _ _ 23-3/4 x 48 x 1" Class A Up to 0.75 • • • • • •

8174T10_ _ _ 23-3/4 x 96 x 1" Class A Up to 0.75 • • • • • •

8173T10_ _ _ 47-3/4 x 96 x 1" Class A Up to 0.75 • • • • • •

Other Size Panels

W 23-3/4" – 48" L: 12" – 144" 1", 1-1/2", or 2" thickness

Class A Up to 0.75 – – – • • •

◆ When specifying or ordering, include the appropriate 3-digit color suffix TNA = Natural TWH = White (e.g. 8182T10 T W H )

* NOTE: Four-sided beveled edge panels are recommended in adjoining panel installations.

VISUAL SELECTION PERFORMANCE SELECTION Dots represent high level of performance.

Mounting A Mounting C-20 Mounting C-40Mounting D-20

ACOUSTICAL MOUNTING METHODS

TECTUM® Direct-Attach Ceiling & Wall Panels coarse texture

High Performance Sustainable

Ceiling Systems

Living Product Imperative Certified

Third Party Verified Declare

SM

LIVING

PRODUCT

CHALLENGE

SM

ACCESSORIES

new new new

Item No. ◆ Description Quantity Item No. ◆ Description Quantity

1222 Truss Fastening Kit – Field Paintable 20/ctn 8187L16_ _ _ #6 x1-5/8" Painted Head – Sharp point Screws 1000/ctn

1222WH Truss Fastening Kit White 20/ctn 8188L16_ _ _ #6 x1-5/8" Painted Head – Drill point Screws 1000/ctn

1222BL Truss Fastening Kit Black 20/ctn 8189L22_ _ _ 2-1/4" Painted Head – CMU Screws 500/ctn

◆ When specifying or ordering, include the appropriate 3-digit color suffix TNA = Natural; TWH = White (e.g. 8187L16 T W H ) Consult installation instructions for fastener guidance.

NOTE: Projects may require alternative screw lengths and types depending on site conditions. Please consult installation instructions for guidance.

Tectum® Direct-Attach Panel 1X Furring

Strips 24" O.C.

Or Equal

Tectum® Direct-Attach Panel

Laid on 3/4" Furring Strips With 1", 3 lb.

Density Fiberglass

2X Furring Strips 24" O.C.

Or Equal

Tectum® Direct-Attach Panel

Laid on 1-1/2" Furring Strips With 2-1/2" Batt Insulation

1X Furring Strips 24" O.C.

Or Equal

Tectum® Direct-Attach Panel

Laid On 3/4" Furring Strips

DRYWALL GRID SYSTEM MOUNTING METHOD

Hanger Wire To Structure

Drywall Cross Tee XL8945

Tectum® Board Mounting Screw

KAM-12

Max Cantilever: 1" Tectum = 3"

Tectum® Panel

4' Drywall Cross Tee

Drywall Main Beam HD8906

Direct-Attach

Hanger Wire To Structure

Drywall Cross Tee XL8945

Tectum® Board Mounting Screw

KAM-12

Max Cantilever: 1" Tectum = 3"

Tectum® Panel

4' Drywall Cross Tee

Drywall Main Beam HD8906

TechLine / 1 877 276-7876 armstrongceilings.com/tectum

BPCS-5716-420

High Performance Sustainable

Ceiling Systems

Living Product Imperative Certified

Third Party Verified Declare

SM

LIVING

PRODUCT

CHALLENGE

SM

D

IR

EC

T-

TO

-D

EC

K

C

EI

LI

N G

S

W A

LL

S

LEED® is a registered trademark of the U.S. Green Building Council Revit® is a registered trademark of Autodesk, Inc.

DeclareSM is a service mark of International Living Future Institute FSC® is a registered trademark of FSC Forest Stewardship Council®, A.C., license code FSC-C007626. All other trademarks used herein are the property of AWI Licensing LLC and/or its affiliates.

© 2020 AWI Licensing LLC Printed in the United States of America

LOCATION DEPENDENT

LE

ED

en er gy an ag em en t re cy cl ab le ex te nd pr od uc er r es p.

bi ob as er ia ls re gi on er ia ls de si gn fo r fle xi bi lit y co ns tr uc tio n w as te m gm t

EP

D

For LEED contribution visit armstrongceilings.com/greengenie m at er ia l in gr ed ie po rt in g re cy c l co en t so ur ci ng o f ra w m at er ia ls lo w e m it g/ er ia ls lig ht qu it y

FS

C

(f or w oo d) ac ou st ic s

RECYCLED

CONTENT92%

TECTUM® Direct-Attach Ceiling & Wall Panels coarse texture

Design Considerations For walls that may experience condensation or moisture, such as uninsulated exterior walls, D- or C- mounting is required to create a gap between the structure and the panel.

Max panel size for Truss and I-Beam application is 2' x 4' x 1".

Design Support Project management assistance is available by calling TechLine at 1 877 276-7876.

Seismic Restraint Tectum Direct-Attach panels are approved for application in all seismic areas when installed per the seismic guidelines in the Armstrong Ceilings Installation Instructions.

Warranty 30-Year Warranty. Details at armstrongceilings.com Weight, Pcs and SF/Pallet 1" – 1.65 lbs/SF 1-1/2" – 2.53 lbs/SF 2" – 3.3 lbs/SF 8180T10 – 36 pcs/pallet; 1,152 SF/pallet 8181T10 – 72 pcs/pallet; 1,152 SF/pallet 8182T10 – 72 pcs/pallet; 572 SF/pallet 8173T10 – 36 pcs/pallet; 1,152 SF/pallet 8174T10 – 72 pcs/pallet; 1,152 SF/pallet 8175T10 – 72 pcs/pallet; 572 SF/pallet

PHYSICAL DATA

Material FSC® Certified Cementitious Wood Fiber; FSC®-certified (COC-003601).

For more information about FSC®-certified fire-retardant products, or to view our FSC®-certification letter, contact TechLine at 1 877 276-7876.

Surface Finish Factory-applied latex paint with Silicate surface coating for abuse resistance. Natural is unpainted.

Fire Performance Class A per IBC. Flame Spread Index 25 or less and Smoke Developed Index 50 or less when tested in accordance with ASTM E84.

CAN/ULC S102 surface burning characteristics. Flame Spread Index of 25 or less and Smoke Developed Index of 50 or less.

VOC Emissions Third-party certified compliant with California Department of Public Health CDPH/EHLB/Standard Method Version 1.1, 2010. This standard is the guideline for low emissions in LEED®, CalGreen Title 24, ANSI/ASHRAE/ USGBC/IES Standard 189; ANSI/GBI Green Building Assessment Protocol.

Tectum® panels meet CDPH guidelines in enclosed office at 50% wall coverage. View certificate details at armstrongceilings.com/tectum.

Humidity/Sag Resistance HumiGuard® Plus performance panels are recommended for areas subject to high humidity, up to, but not including, standing water and outdoor applications.

Mold/Mildew Protection Ceiling panels with BioBlock® performance resist the growth of mold and mildew.

Installation Considerations Panels must be mechanically attached to approved substrate per installation instructions. To achieve proper finished visual panels should be installed in an ashlar pattern. Four-sided beveled edge panels are recommended in adjoining panel installations.

Use caution and wear appropriate hand, eye, and dust mask protection when cutting and installing Tectum panels. Refer to installation instructions for complete details and cutting recommendations.

Primary (Embodied) Energy See all LCA information on our EPDs.

Application Considerations Color variation among panels is common due to the natural characteristics of the wood on White and Natural panels.

Wood fibers may appear orange on Natural colored panels due to the characteristics of the wood.

EDGE DETAIL

NOTE: Stacked bond patterns are possible, but not recommended. Field trimming panels may be required to achieve desired fit and alignment.

NOTE: Use Beveled Edge/Square End for the above panel layout.

Long Edges Beveled

Short Edges Squared

Beveled Edge

Square Edge

Long Edges Beveled

Short Edges Beveled new

Tectum Direct-Attach 1" Thick 24" x 48" Panel 4" 4"

16" O.C.

Truss Fastening Kit

Truss Installation Truss Fastening KitI-Beam Installation

Tectum Direct-Attach 1" Thick 24" x 48" Panel 1" 1"

22"

8187L16 Sharp Point Screws

Max Truss Width

4" Max Truss Width

Truss Fastening Kit

I-BEAM AND TRUSS INSTALLATION

Long Edges Beveled

Short Edges Beveled

Long Edges Beveled Short Edges Beveled

Long Edges Beveled

Short Edges Beveled Beveled Edge

NOTE: Use Beveled Edge/ Beveled End panels for all adjoining panel installations.

TE

CT

UM

Ceiling & Wall Panels

TECTUM®

Ceiling & Wall Panels

4 6 7 8

10 12 1411

Tectum® ceiling and wall panels provide durable, sustainable, acoustical solutions with unlimited design options. Tectum 1" thick panels are part of the Sustain® portfolio and meet the most stringent sustainability standards today. They are the first and only acoustical ceiling and wall solutions that are Living Product Imperative Certified by the International Living Future Institute.

FABRIC WALLS/

PANEL ART

CEILINGS & WALLS

SIZES, COLORS &

ACOUSTICAL

PERFORMANCE

FINALE™ HIGH NRC

CEILINGS & WALLS

LAY-IN & TEGULAR

CEILINGS

SHAPES &

CLOUDS

BLADES™ &

BAFFLES

SUSTAINABILITY DIRECT-ATTACH

CEILINGS & WALLS

Direct-Attach in custom colors;

Kalamazoo Public Library, Kalamazoo, MI;

David Milling Architects, Ann Arbor, MI

Tectum® Direct-Attach Ceiling Panels; Temple School of Architecture, Philadelphia, PA; NELSON, Philadelphia, PA

Here's how:

- Contribute to LEED® v4 (including new

Materials and Resources credits)

- Have Health Product Declarations (HPDs) which tell you what's in the products

- Are free of Red List chemicals per Living

Building ChallengeSM 3.0 (including no added formaldehyde)

- Have DeclareSM labels – easy reference “nutrition labels”

- Meet California Department of Public Health (CDPH) low emissions standards

- Have Environmental Product Declarations (EPDs) which tell you the impact of the products

- Contribute to Living Building Challenge

- Contribute to WELL Building StandardTM

THE SUSTAIN®

Portfolio Contributes To Better Spaces

High Performance Sustainable

Ceiling Systems

1" Thick Tectum® Panels in White and Natural

White

(TWH)

Natural

(TNA)

Wisconsin Aspen Trees

LIVING PRODUCT Challenge Tectum® is made of fibers from one of the most sustainably harvested trees of its kind, the Wisconsin Aspen. The part of the Aspen that grows above ground can live between 40-150 years.

The root system of the Aspen can survive thousands of years.

Aspen quickly regenerate from their root system after the trunks have been harvested.

Tectum products are made of natural fibers and binders that are turned into unique, sound absorbing, textured ceiling and wall panels that bring nature inside. Ideal for spaces where sustainability, durability, and noise control are needed.

Tectum panels are the first and only acoustical ceiling and wall solution to be Living Product Imperative Certified by the International Living Future Institute.

LIVING

PRODUCT

CHALLENGE

SM

Vertical elements control acoustics with an upscale linear visual.

Blades™ & Baffles

FIT TO THE MAX

- Upscale linear visual adds acoustics and aesthetics to any space

- Noise absorption up to 0.50 Sabins/SF

- Custom shapes and sizes available to meet your project needs

- Mounting channels available to extend panel length beyond four feet

Tectum® Blades™ custom vertical panels; Capital One Labs, San Francisco, CA

Hang with hanger wire or aircraft cables

- Noise absorption up to 0.50 Sabins/SF

- Wide variety of color options available

- Installs with 15/16" Prelude® suspension system

- Square or radius edges

- Made in sizes up to 4' and can be suspended or direct-attached to drywall grid system

Tectum® Clouds; Retail Me Not, Austin, TX; STG Design, Austin, TX

12 ga.

Hanger

Wire

Prelude® 15/16" Tee

Tectum® Clouds and Shapes

Shapes and Clouds offer design flexibility in a floating system.

Shapes & Clouds

FLEXIBLE FIT

Tectum® Panel Art and Direct-Attach wall panels in White and custom colors;

Boys & Girls Club of Lancaster, Lancaster, PA

Tectum® Direct- Attach Panel

Laid on 3/4" Furring Strips

1X Furring

Strips 24" O.C. or

Equal

High Performance Sustainable

Ceiling Systems

Install panels directly to ceilings and walls to add durability and noise reduction to a wide variety of spaces using a sustainable solution.

Direct-Attach

FIT THE BILL

- Now, 1" panels in White and Natural are Living Product Challenge Certified by the International Living Future Institute

- 1" thick panels are part of the Sustain® portfolio

- FSC® Certified Panels

- Excellent sound absorption – NRC up to 1.0

(mounting and thickness dependent)

- Retrofit solution for noise reduction

- Can be mechanically fastened to a wide variety of surfaces

- Now you can install 1" thick Tectum® on Trusses and I-Beams for added acoustics while maintaining an exposed structure visual on the deck

- Durable for heavy-use interiors, pools, and exterior-covered spaces new

6.00

5.00

4.00

3.00

2.00

1.00

0.00

Frequency Hz

Boys and Girls Club Gymnasium

Re ve rb er at io n tim e

Average (Before)

5.05

1.85

Average RT

Average (After) the cha l lenge:

The gymnasium at the Boys & Girls Club of Lancaster is in use every day, not only for sports activities but a variety of other functions as well. Its acoustic environment, however, was not always ideal.

Acoustical testing showed that reverberation time in the gym was

5.05 seconds, far above the 2.00 seconds or less recommended for this type of space. As Karen Schloer, the Club’s Chief Executive

Officer, notes, “The noise level was putting a real strain on the staff because they had to shout so often when trying to communicate with the kids.”

the so lu t ion :

To solve the problem, Armstrong Ceiling and Wall Solutions installed more than 3,500 square feet of Tectum® Direct-Attach wall panels on the gym’s masonry walls. The panels were chosen because of their ability to absorb both sound and the impact of basketballs, volleyballs, and other objects that hit the walls.

Aesthetically, the two-inch-thick, 2' x 4' panels are installed in ribbons of white and a custom blue that match the Club’s colors.

They start nearly 10-feet off the floor and continue up the wall another 18-feet.

In addition, a re-creation of the Boys & Girls Club logo is installed at each end of the gym. The 15-feet wide and 13-feet high visual of two interlocking hands was created using eight-inch triangular

Tectum Panel Art shapes. The white triangles are one-inch thick, while the blue triangles are two-inches thick so that they stand out from the wall. Two rows of 12 SoundSoak® Baffles were installed in the center of the ceiling for added noise absorption.

Acoustically, the 2" Direct-Attach Tectum wall panels have a Noise

Reduction Coefficient (NRC) of 0.70. Acoustical testing conducted after the installation of the combination acoustical treatment showed that reverberation time dropped to 1.85 seconds, a 63% reduction.

According to Chief Operations Officer, Scott McLellan, "The difference is like night and day. The biggest takeaway is how much easier it is now for the staff to gain control of the space because the kids can hear directions much more clearly."

Looking back at the difference in the gym’s acoustic comfort, McLellan adds, “The staff simply didn’t realize how bad it was because they didn’t realize how good it could be.”

Project | Boys & Girls Club of Lancaster Location | Lancaster, PA Architect | You Inspire™ Solutions Center Product | Tectum® Direct-Attach Wall Panels, Tectum Panel Art Shapes and SoundSoak® Baffles

CASE STUDY

Boys & Girls Club Gymnasium

- Abuse-resistant composite panel design for maximum noise reduction and efficient installation

- Excellent sound absorption – NRC up to 0.95 (2" panels)

- Variety of color options available

- Can be mechanically fastened to a wide variety of surfaces

Tectum® Finale™ high NRC ceiling panels

Finale™ ceiling and wall panels offer maximum noise reduction and install 2.5x faster than C-20 mount Direct-Attach panels for reduced installation costs. A perfect way to add acoustics to exposed structure spaces.

Finale™ High NRC

A SOUND FIT

Integrated Acoustical Insulation

Integrated Furring Strip

- Now, 1" panels in White and Natural are Living Product Challenge Certified by the International Living Future Institute

- 1" thick panels are part of the Sustain® portfolio

- Tegular panels have Total Acoustics® Performance

(NRC 0.90 CAC 35) with 1713 infill panel

- FSC® Certified Panels

- Durable for heavy-use interiorsLay-In & Tegular

FIT FOR PURPOSE

Tectum® Tegular 24" x 48" panels in White with Prelude® XL® 15/16" suspension system

Durable, sustainable, noise control for spaces requiring acoustics and design flexibility.

Prelude® XL®

Main Beam

Lay-in Panels

Tegular Panels

High Performance Sustainable

Ceiling Systems

Fabric walls do double duty, providing both acoustics and a tackable surface for displays and bulletin boards.

Fabric Walls

TWICE THE FIT

- Abuse-resistant, fabric-wrapped panels attach directly to walls

- Excellent Noise Absorption – NRC up to 0.90

- Mounting is quick and easy using internal spline system

- Durable fabric options available

Tectum® Fabric wall panels; Southland Christian Church, Lexington, KY

Fabric Wall – Decor Clip

8" x 16" Rectangle 8" Square 8" Circle 8" Triangle 16" Triangle

8" x 16" Right Parallelogram

8" x 16" Left Parallelogram

7.5" Hexagon

Tectum® Panel Art ceiling and wall panels; Armstrong World Industries, Lancaster, PA

Panel Art

FIT TO A “T”

Create your own custom shapes, or use one of eight prefabricated geometrics to help your ceiling and wall designs take shape.

- Available in eight shapes, or create custom shapes from panels up to 48" x 48"

- Excellent sound absorption – NRC up to 1.0

- All panels have beveled edges on all four sides

- Can be mechanically fastened to a wide variety of surfaces

- Now, 1" panels in White and Natural are

Living Product Challenge Certified by the International Living Future Institute

- White or Natural 1" thick panels are part of the Sustain® portfolio

Tectum® ceiling and wall panels are available in a variety of sizes, shapes, forms, and colors. Select from a natural factory finish, white, or made-to-order colors. Panels can be field-painted up to six times without impacting acoustic or fire performance. Tectum panels are made to fit your design needs.

TECTUM®

MADE TO FIT

Tectum® Direct-Attach Wall Panels;

Chula Vista Elementary School, San Diego, CA;

Ruhnau Ruhnau Clarke, Riverside, CA

Tectum Panel Art & Shapes Panels;

Boys & Girls Club, Lancaster, PA

TECTUM® PANELS

Width Length Thickness

Blades™ & Baffles 23-3/4" – 47-3/4" 11-3/4" – 23-3/4"* 1", 1-1/2", 2"

Shapes & Clouds 23-3/4" – 47-3/4" Up to 96" 1-1/2", 2"

Direct-Attach 23-3/4" – 47-3/4" 48" – 144" 1", 1-1/2", 2"

Finale™ High NRC 23-3/4" – 47-3/4" 48" – 144" 1", 1-1/2", 2"

Panel Art 47-3/4" 48" ** 1", 1-1/2", 2"

Lay-in & Tegular 23-3/4" – 47-3/4" 23-3/4" – 47-3/4" 1", 1-1/2", 2"

Fabric Walls 23-3/4" – 47-3/4" 48" – 120" 1", 1-1/2", 2"

* Available height for Blades™ & Baffles. Length can extend beyond 4' with mounting channels.

** Larger custom sizes available upon request.

EDGE DETAIL RECOMMENDATIONS

STANDARD COLORS

White

(TWH)

Natural

(TNA)

Custom Colors Available

Tectum® Direct-Attach Panel

Laid Directly Against Wall Surface

Mounting A Mounting C-20 Mounting C-40Mounting D-20

ACOUSTICAL MOUNTING METHODS

1X Furring Strips 24" O.C. or Equal

Tectum® Direct-Attach Panel

Laid on 3/4" Furring Strips (1" nominal) With 1", 3 lb.

Density Fiberglass

2X Furring Strips 24" O.C. or Equal

Tectum® Direct-Attach Panel

Laid on 1-1/2" Furring Strips (2" nominal) With 2-1/2" Batt Insulation

1X Furring Strips 24" O.C. or Equal

Tectum® Direct-Attach Panel

Laid on 3/4" Furring Strips (1" nominal)

SI

ZE

S

CO

LO

RS

AC

OU

ST

IC

S

Long edges beveled

Short edges beveled

Layout not recommended. Contractor will likely need to �eld trim to achieve desired �t.

Long edges beveled

Short edges squared

Beveled edge

Square edge

Long edges beveled

Short edges beveled

Long edges beveled

Short edges beveled

Long edges beveled

Short edges beveled Beveled edge

NOTE: Stacked bond patterns are possible, but not recommended. Field trimming panels may be required to achieve desired fit and alignment.

NOTE: Use Beveled Edge/Square End for the above panel layout.

NOTE: Use Beveled Edge/Beveled End panels for all adjoining panel installations.

Product

Panel Thickness

Mounting

NRC Rating Weight (Sq.Ft.) Suspended A Mounting D-20 Mounting C-20 Mounting C-40 Mounting

Blades™ & Baffles 1" 1.63 lbs/SF 0.40 (Sabins/Sq. Ft.)

1-1/2" 2.53 lbs/SF 0.50 (Sabins/Sq. Ft.)

Shapes & Clouds 1-1/2" 2.55 lbs/SF 0.50 (Sabins/Sq. Ft.)

Lay-in & Tegular Ceiling Panels

1" 1.63 lbs/SF 0.40 – – – –

1" w/ 1713 Infill – 0.90/CAC 33 – – – –

1-1/2" 2.53 lbs/SF 0.50 – – – –

Fabric Walls 1" 1.63 lbs/SF – 0.50 0.60 – 0.90

Direct-Attach Ceiling & Wall Panels

1" 1.63 lbs/SF I-Beam: 3.8 (Sabins/ 2' x 4' x 1" Tectum panel)

Truss: 2.9 (Sabins/ 2' x 4' x 1" Tectum panel)

0.40 0.45 0.80 0.85

Panel Art Ceiling & Wall Panels

1-1/2" 2.53 lbs/SF 0.55 0.60 0.90 0.95

2" 3.30 lbs/SF 0.60 0.70 0.95 1.00

Finale™ Ceiling & Wall Panels

1" Panel with Integral Minwool Insert & 1" Furring

3.00 lbs/SF 0.85

1-1/2" Panel with Integral Minwool Insert & 1" Furring

3.50 lbs/SF 0.90

2" Panel with Integral Minwool Insert & 1" Furring

4.06 lbs/SF 0.95

TAKE

THE NEXT

STEP

BPCS-5496-719

1 877 276-7876

Customer Service Representatives

7:45 a.m. to 5:00 p.m. EST

Monday through Friday

TechLine – Technical information, detail drawings, CAD design assistance, installation information, other technical services – 8:00 a.m. to 5:30 p.m. EST, Monday through Friday. FAX 1 800 572-8324 or email: techline@armstrongceilings.com armstrongceilings.com/tectum

Latest product news

Standard and custom product information

Online catalog

CAD, Revit®, SketchUp® files

A Ceiling for Every Space® Visual Selection Tool

Product literature and samples – express service or regular delivery

Contacts – reps, where to buy, who will install

YOU INSPIRE™ SOLUTIONS CENTER

1 800 988-2585 email: solutionscenter@armstrongceilings.com armstrongceilings.com/youinspire

Design Assistance

Collaborative design

Detail drawings

Specifications

Planning and budgeting

Pre-construction Assistance

Layout drawings for standard and premium products

Project installation recommendations

Contractor installation assistance armstrongceilings.com/tectum

FSC® is a registered trademark of FSC Forest Stewardship Council®, A.C., license code FSC-C007626 Inspiring Great Spaces® is a registered trademark of AFI Licensing LLC LEED® is a registered trademark of the U.S. Green Building Council Revit® is a trademark of Autodesk, Inc.; SketchUp® is a registered trademark of Trimble, Inc.

DeclareSM and Living Building ChallengeSM are service marks of International Living Future Institute WELL Building Standard™ is a trademark of The International WELL Building Institute (IWBI) All other trademarks used herein are the property of AWI Licensing LLC and/or its affiliates © 2019 AWI Licensing LLC • Printed in the United States of America helping to bring your one-of-a-kind ideas to life

APPENDIX B

(Roof System Cut Sheets)

Project Overview

Project:

Building 53 C, D & E Roof Replacement

3900 NCTR Road

Jefferson, AR 72079

Roof System Manufacturer:

Siplast

Warranty:

20- Year Siplast Full System Warranty

Assembly 1 at Building 53C & 53D Roofs:

1. Deck: Lightweight Insulating Concrete over EPS board over gypsum deck

2. Slope: ¼” per foot

3. Substrate Preparation: PA-1125 Primer

4. Temporary Roof: IREX 40

5. Insulation: No new insulation at 53C & 53D Roofs

6. Coverboard: ½” Densdeck Prime in Parafast Adhesive

7. Roof System: Paradiene 20 TG / Paradiene 30 FR TG; Torch Applied

8. Flashing System: Veral Aluminum / Parapro

Assembly 2 at a Building 53E Roof:

1. Deck: Lightweight Insulating Concrete

2. Slope: 1/4” per foot

3. Substrate Preparation: PA-1125 Primer

4. Temporary Roof: IREX 40

5. Insulation: 2” Paratherm in Parafast Adhesive

6. Coverboard: ½” Densdeck Prime in Parafast Adhesive

7. Roof System: Paradiene 20 HT TG / Paradiene 30 HT FR TG; Torch Applied

8. Flashing System: Veral Aluminum / Parapro

Sheet Metal Flashings:

Per plans and specifications replace existing counterflashing, gutters, and downspouts. Instal to match existing conditions.

Siplast 1000 Rochelle Blvd.

Irving, TX 75062-3940

201 Bewicke Ave., Suite 208 North Vancouver, BC, Canada V7M 3M7

Customer Service in North America

1.800.922.8800 www.siplast.com

PA-1125 PRIMER

Commercial Product Data Sheet

Product Description PA-1125 Primer is an asphalt solvent blend designed to prepare metal, concrete, and masonry surfaces prior to application of bituminous Siplast Roofing and Flashing Systems.

Product Uses PA-1125 Primer is applied to metal flanges, concrete, and masonry surfaces; the primer should be allowed to dry thoroughly prior to application of Siplast Roofing and Flashing Systems. PA-1125 Primer can be applied by roller brush or spray. Do no dilute or cut PA-1125 Primer with solvents.

Diluting PA-1125 using petroleum solvents will affect its bonding and drying characteristics.

Product Approvals PA-1125 meets or exceeds ASTM D 41 requirements for asphalt primer used in roofing and waterproofing.

VOC content: This product contains an average 393 g/l VOC.

Current copies of all Siplast Commercial Product Data Sheets are posted on the Siplast Web site at www.Siplast.com.

oÉî=RLOMNU

COMMERCIAL PRODUCT INFORMATION

Unit: 5-Gallon Pail

4.7 gallons (17.8 liters) net content

Coverage: Coverage is dependent on the condition of the surface receiving the primer. The coverage ranges from 100 square feet per gallon (0.4 liter per 1/m²) on very rough, porous surfaces to 400 square feet per gallon (1.6 1/m²) on smooth, low-absorptive surfaces.

Flash Point, Pensky-Martens Closed Cup: 100°F (38°C)

Packaging: The pails are stacked three high on pallets and stretch wrapped.

Pallet: 45 in X 48 in (114 cm X 122 cm) wooden pallet Number Pails Per Pallet: 42 Number Pallets Per Truckload: 22 Weight Per Pail: 37 lb (16.8 kg)

Shipping Classifications: White Label (combustible)

Storage and Handling: All containers of PA-1125 Primer should be stored upright on a clean, flat surface. Care should be taken that containers are not dropped and container seals are not broken prior to use. All containers should be stored in a dry place, out of direct exposure to the elements, and should be kept away from excessive heat, fire or open flames.

201 Bewicke Ave., Suite 208 North Vancouver, BC, Canada V7M 3M7

Customer Service in North America

1.800.922.8800 www.siplast.com

IREX 40

Commercial Product Data Sheet

Product Description Irex 40 is a high performance, heavy duty base sheet or base ply designed for use with Veral and other torchable roof membrane systems. Irex 40 consists of a lightweight random fibrous glass mat impregnated and coated with a specially formulated, styrene-butadiene-styrene (SBS) modified bitumen.

Irex 40 is available with Siplast RoofTag RFID roof asset technology on a Special-Made-To-Order basis. See RoofTag Commercial Product Data Sheet for more information.

Product Uses Irex 40 is used as a ply sheet or base sheet depending on specification requirements for Siplast Veral and other Siplast Roof Systems. Irex 40 is lapped 3 inches (7.6 cm) side and end when applied in approved Type IV asphalt or by torching.

In nailable applications, Irex 40 is lapped 4 inches (10.2 cm) side and end, and is mechanically fastened according to Siplast requirements. Contact Siplast for specific approval on other product uses.

Product Approvals Irex 40 is approved by FM Approvals (FM Standard 4470) for use in Veral Class 1 insulated steel roof deck constructions and insulated and non-insulated concrete roof deck constructions, subject to FM conditions and limitations.

Irex 40 has been classified by Underwriters Laboratories as a UL Rated G2 Base Sheet. Irex 40 is approved by Underwriters Laboratories for use in cULus Classified Siplast Veral Roof Systems. Veral has been classified by Underwriters Laboratories as a Class A roofing system over non-combustible, insulated non-combustible, insulated combustible, and combustible decks.

Irex 40 meets or exceeds the requirements of ASTM D 6163 Type I, Grade S, and CSA A123.23-15 Type A, Grade 2 for SBS-modified bituminous sheet materials using glass fiber reinforcements.

Siplast Roof Systems also have received the approval of many regional and local authorities. Please contact Siplast for specific information as required.

Unit: Roll

Coverage: 1.0 Square (9.3 m²)

Coverage Weight Per Square:

Min:

85 lb

(4.1 kg/m²)

Roll Length: Min: 34 ft (10.36 m)

Roll Width: Avg: 3.28 ft (1.0 m)

Thickness: Avg:

110 mils 106 mils

(2.8 mm) (2.7 mm)

Selvage Width: N/A

Selvage Surfacing: N/A

Top Surfacing: Silica Parting Agent

Back Surfacing: Silica Parting Agent

Lines: Two laying lines are placed 3 in (7.6 cm) and 4 in (10.2

cm) from each edge of the material. The line color for this material is blue.

Packaging: Rolls are wound onto a compressed paper tube.

The rolls are placed upright on pallets cushioned with corrugated cardboard and are adhered with adhesive at the labels. The top of the palleted rolls is covered with Kraft paper. The palleted material is protected by a heat shrink polyethylene shroud.

Pallet: 41 in X 48 in (104 cm X 122 cm) wooden pallet Number Rolls Per Pallet: 25 Number Pallets Per Truckload: 18 Minimum Roll Weight: 85 lb (38.6 kg)

Storage and Handling: All Siplast roll roofing products should be stored on end on a clean flat surface. Care should be taken that rolls are not dropped on ends or edges and are not stored in a leaning position. Deformation resulting from these actions will make proper installation difficult. All roofing should be stored in a dry place, out of direct exposure to the elements, and should not be double stacked. Material should be handled in such a manner as to ensure that it remains dry prior to and during installation.

Rev 5/2018

IREX 40

Physical and Mechanical Properties

UNITED STATES TEST STANDARDS CANADA TEST STANDARDS

Property

(as Manufactured)

Values/Units

Test

Method Property

(as manufactured)

Test Method

CSA A123.23-15

Thickness (minimum)

106 mils (2.7 mm) ASTM D 5147 section 6

Thickness (minimum) 2.7 mm (106 mils)

Thickness (average)

110 mils (2.8 mm) ASTM D 5147

Thickness (average) 2.8 mm (110 mils)

¹Peak Load @ 73F (23C) (average)

45 lbf/inch (7.9 kN/m)

ASTM D 5147

section 7

¹Peak Load 23C (73˚F) (average)

7.9 kN/m (45 lbf/inch)

¹Peak Load @ 0F (-17C) (average)

80 lbf/inch (14.1 kN/m)

ASTM D 5147

section 7

¹Peak Load @ -17C (0F) (average)

14.1 kN/m (80 lbf/inch)

¹Elongation @ Peak Load, 73F (23C) (average)

3%

ASTM D 5147

section 7

¹Elongation @ Peak Load, 23C (73F) (average)

¹Elongation @ Peak Load, 0F (-17C) (average)

2% section 7

¹Elongation @ Peak Load, -17C (0F) (average)

2%

¹Tear Strength (average)

60 lbf (0.27 kN)

ASTM D 5147

section 8

N/A N/A

Water Absorption (maximum)

1% section 10

N/A

N/A

Dimensional Stability

0.1% section 11

Low Temperature Flexibility (maximum)

0°F (-18°C) ASTM D 5147

section 12

Low Temperature Flexibility

-18°C (0°F)

Compound Stability (minimum)

215ºF (102ºC) section 16

Compound Stability (minimum) 102ºC (215ºF)

Coating Thickness - Back Surface

40 mils (1 mm) ASTM D 5147 section 17

Coating Thickness - Back Surface

1 mm ( 40 mils)

Mass Per Unit Area (minimum)

4.1 kg/m² (85 lb/sq)

1. The value reported is the lower of either MD or XD.

201 Bewicke Ave., Suite 208 North Vancouver, BC, Canada V7M 3M7

Parafast Insulation Adhesive T

Siplast Parafast Insulation Adhesive T is a quick curing, two-component, bead-applied polyurethane adhesive used to adhere approved rigid insulation board stock. Parafast Insulation Adhesive T is packaged in metal tanks (canisters) encased in boxes to facilitate storage and handling. Each kit includes a set of two tanks, a disposable hose/gun, six mixing tubes, and three 17-inch extension tubes that allow for stand-up application. No supplemental application equipment is required.

Product Uses Siplast Parafast Insulation Adhesive T is used to adhere approved rigid insulation panels to rigid insulation panels and to substrates approved in advance by Siplast for roof constructions requiring a single-source guarantee.

Approved insulation panels include Paratherm, DensDeck Prime®, SECUROCK®, and high-density fiberboard.

Approved substrates include previously-applied insulations as listed above, cured poured-in-place concrete, pre-cast concrete, approved ply sheets and approved nailed base sheets. The product temperature for Parafast Insulation Adhesive T at the point of application is 70°F (21°C) to 90°F (32°C). The ambient and substrate temperature range is 40°F (5°C) to 100°F (38°C). Once applied, the adhesive cures chemically in approximately 10 - 12 minutes, depending on ambient and substrate conditions.

Polyisocyanurate insulation panels applied in Parafast Insulation Adhesive must have a maximum panel size of 4 feet x 4 feet (1.22 m x 1.22 m). Contact Siplast for specific approvals on other substrates and insulation products. See the Siplast Para-Stik and Parafast Insulation Adhesive Usage and Estimating Guide for further information.

Product Approvals Parafast Insulation Adhesive may be used as a component in roof constructions requiring a rating for exterior fire resistance as outlined in the latest edition of the UL Roofing

Materials & Systems Directory. Parafast Insulation Adhesive is FM Global Approved as a component for use in Class 1 rated constructions when used according to FMG requirements. Contact Siplast for further information on uplift approvals, specific listings, and other agency approvals.

Safety Protective clothing, including gloves and protective eyewear, should be used when Parafast Insulation Adhesive is being dispensed. Do not expose Parafast insulation Adhesive T to open flame or ambient temperatures in excess of 100°F (38°C). See SDS for detailed information.

Unit: Part 1 (diisocyanate) - 48 lb (21.8 kg) gross weight (including packaging) Part B (resin) - 44 lb (19.6 kg) gross weight

(including packaging)

Packaging: Metal tanks (canisters) are packaged in a corrugated box with a single unit (Part 1 or 2) per box. Part 2 includes the disposable hose/gun assembly and related parts.

Number of units per pallet (Parts 1 and/or 2): 32 units per pallet

Storage and Handling: Parafast Insulation Adhesive T has a shelf life of 18 months from the date of manufacture.

Parafast Insulation Adhesive T should be stored in a cool dry location at temperatures between 55°F (13°C) and 85°F (30°C). Do not allow Parafast Insulation Adhesive to freeze under any circumstances. Store materials out of direct exposure to the elements. All material stored on the roof overnight should be stored on pallets. When storing materials on the roof, do not overload the deck or structural assembly.

Disposal: Do not discharge uncured product into lakes, streams, ponds or other bodies of water. Spilled, uncured product, unused containers and empty containers should be neutralized and disposed of in accordance with local, state, provincial and federal regulations.

Rev 7/2018

201 Bewicke Ave., Suite 208 North Vancouver, BC, Canada V7M 3M7

Customer Service in North America

1.800.922.8800 www.siplast.com

PARATHERM & PARATHERM CG

POLYISOCYANURATE INSULATION

Commercial Product Data Sheet

Product Description Paratherm is a rigid roof insulation board comprised of a…

This is the start of the file's text. The full file is on GovTribe.