Attachment III - QAPS.pdf
PDF 6 MB Posted
- Attached to
- CONTRACTOR-OWNED, CONTRACTOR-OPERATED (COCO) FUEL STORAGE SERVICES IN DAVAO, PHILIPPINES
- Solicitation number
- SPE603-26-R-0522
- Issued by
-
Defense Logistics Agency Energy
About this file
This document is Attachment III – Quality Assurance Provisions (QAPs) for federal contract SPE603-26-R-0522 related to petroleum product storage and additive handling services in Davao, Philippines, administered by the Defense Energy Support Center and Defense Logistics Agency Energy.
The QAPs establish comprehensive quality control and inspection requirements for contractor-performed services including bulk petroleum storage tank inspection and cleaning, fuel system icing inhibitor (FSII) and lubricity improvement additive (LIA) handling, and associated transportation. Key provisions include: contractors must prepare and maintain Quality Control Plans (QCP) in triplicate, provide all inspection and testing facilities at contractor expense, maintain historical tank data and service records, and perform routine sampling and testing per ASTM standards. For aviation fuel storage tanks, cleaning frequencies range from every 4 years (uncoated tanks without inlet-filter separators) to every 8 years (coated tanks with inlet-filter separators); ground and marine fuel tanks require cleaning when sample analysis indicates sediment buildup. Contractors must retain product composite samples for 15-90 days depending on shipment method and retain tank inspection/cleaning records throughout the contract period. Government quality representatives have unrestricted access to contractor equipment and facilities for testing. Sample requirements, test methods, tank car/truck preparation procedures, and cleaning protocols for prior cargoes are detailed in accompanying tables specifying ASTM standards and chemical cleaning procedures. Contractors bear costs for routine inspection and testing services as part of monthly service charges, except for higher-order analysis testing which is reimbursable, and are responsible for all fines or penalties from environmental agencies related to nonconforming supplies.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPE603-26-R-0522
Attachment III - QAPs
Davao, Philippines
SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)
REVISIONS
REV DESCRIPTION DATE APPROVED
ENERGY QAP E28 February 2022
E28 CONTRACTOR INSPECTION RESPONSIBILITIES (STORAGE)
(a) Inspection and tests by the Government of services, facilities, and equipment specified within this contract does not relieve the Contractor from responsibility to meet all requirements of the contract.
(b) The Contractor shall furnish personnel, facilities, and equipment on-site to accomplish the following routine tests and procedures. These on-site resources may be provided by Contractor personnel or by a commercial source action on behalf of the Contractor. The Quality Representative will not be responsible for performing any of these services for the Contractor.
(1) Sampling of storage tanks, shipments and receipts in accordance with ASTM D4057, Standard Practice for Manual Sampling of Petroleum and Petroleum Products (API Manual of Petroleum Measurement Standards (MPMS), Chapter 8.1);
(2) Retaining of product composite samples from shipments and receipts as follows:
MINIMUM
METHOD OF SHIPMENT MINIMUM QUANTITY RETENTION PERIOD
Pipeline 20 liters 60 days
Tanker/Barge Parcel Composite 20 liters 90 days
Each compartment 0.5 liters 90 days
Navy Fleet Oilers/Vessels 10 liters 60 days
Tank Truck/Car 1 liter 15 days
NOTE: After the minimum retention period, samples shall be tested for Appearance, Color (Visual), API Gravity/Density and Flash Point and, if found to be on-specification, shall be returned to like Government stock on-site. Sample containers may be reused if properly cleaned.
(3) Determining the presence of water in storage tanks, shipments and receipts. Ensure that accurate water cuts are obtained by means of a water indicating paste conforming to MIL-W-83779B. Two suggested sources are Stewart Hall Chemical Testmaster Water Indicating Paste or Sartomer
Sar Gel Water Indicating Paste (see Note 2 below);
(4) Determining Density at 15 degrees Celsius or API gravity of products by ASTM D1298 or ASTM D4052 (see Note 2 below);
(5) Determining the temperature of products by the API MPMS, Chapter 7 (see Note 2 below);
(6) Determining the Appearance of applicable products using ASTM D4176, Procedure l (see Note 2 below);
(7) Determining the visual color of products.
(8) Determining the Flash Point of applicable products using test methods cited in the appropriate product specification (see Note 2 below);
(9) Conversion of gross to net gallonage (liters);
(10) Determining the percentage (volume) of fuel system icing inhibitor (FSII) by means of a portable refractometer in accordance with ASTM D
5006. One suggested source is H.B. Industries, Inc., Glenview, IL 60025 (B/2 Anti-Icing Additive test kit) (see Note 2 below); and
(11) Determining the range of fuel electrical conductivity using ASTM D2624. One suggested source for a conductivity meter is Emcee
Electronics, Inc., Sarasota, FL 33581 (Model 1152) (see Note 2 below)
SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)
DEFENSE ENERGY SUPPORT CENTER
8725 JOHN J. KINGMAN RD
FORT BELVOIR, VIRGINIA 22060-6222
DISTRIBUTION ITEM
STATEMENT -A ENERGY QAP E28
APPROVED FOR NSN CODE IDNO.
PUBLIC RELEASE MULTIPLE 52838
DISTRIBUTION IS SIZE SCALE DRAWING NUMBER
"UNLIMITED"
DLA FORM 1889, OCT 2011 PREVIOUS EDITION IS USABLE Add Continuation Page SHEET 1 OF 2 PDF(DLA)
SPE603-26-R-0522
SUPPLEMENTAL QUALITY ASSURANCE PROVISION (SQAP)
REVISIONS
REV DESCRIPTION DATE APPROVED
ENERGY QAP E28 February 2022
Note 1: All costs for providing the above tests and procedures shall be included in the monthly service charge. The only exception to the
Contractor's obligation to provide these services as part of the monthly service charge is when the tests described above are part of the higher order analysis (defined as the following categories: Composite Samples, Storage Tanks After Receipt, Interface Mixtures, Dormant
Stocks and Individual Tests (including particulate contamination) found in the MIL-STD-3004-1 Table titled MINIMUM SAMPLING AND
TESTING REQUIREMENTS FOR PETROLEUM PRODUCTS.
Note 2: Upon request, the Contractor shall permit the Quality Representative unrestricted use of the equipment and ancillary supplies needed to perform this test/procedure on behalf of the Government.
(c) During the contract, the Contractor shall furnish representative samples of the product in each storage tank, shipment or receipt at the request of, and in the manner and to the place designated by, the Quality Representative. Sample size will be 2 gallons for gasoline-type fuels and one gallon or 10 gallons for jet diesel-type fuels. The number of samples to be furnished during any 12-month period shall not exceed eight times the number of tanks specified in the contract. Such samples shall be packed, marked, and shipped by the Contractor, shipping expense prepaid, in containers and shipping boxes furnished by the Contractor. Sample containers shall be epoxy coated on the interior. This requirement is in addition to sampling required elsewhere in this contract provision and the contract. All reasonable direct shipping costs associated with samples required by this paragraph shall be reimbursed upon request from the Contractor and such costs shall not be included in the monthly service charge.
However, all other costs related to this requirement shall be included as part of the monthly service charge.
SUPPLEMENTAL QUALITY ASSURANCE PROVISION
(SOAP)
DEFENSE ENERGY SUPPORT CENTER
8725 JOHN J. KINGMAN RD
FORT BELVOIR, VIRGINIA 22060-6222
DISTRIBUTION STATEMENT -A
APPROVED FOR PUBLIC RELEASE
DISTRIBUTION IS "UNLIMITED"
SIZE SCALE CODE IDNO.
52838
DRAWING NUMBER
DLA FORM 1889, OCT 2011 PREVIOUS EDITION IS USABLE Add Continuation Page SHEET 2 OF 2 PDF(DLA)
SPE603-26-R-0522
| ENERGY QAP E18 INSPECTION AND CLEANING (FEB 2017).pdf |
| Attachment II - DLAE Quality Assurance Supplemental Guidance |
| ENERGY QAP E1.01_Redacted |
| ENERGY QAP E1.11-1_Redacted |
| ENERGY QAP E18_Redacted |
| ENERGY QAP E22_Redacted |
| ENERGY QAP E28_Redacted |
| ENERGY QAP E29_Redacted |
| ENERGY QAP E30.01_Redacted |
| ENERGY QAP E35_Redacted |
File details come from the government source that posted it. Updated .