Attachment H - WO799152dwg25of35PLUMBING.pdf

PDF 15 MB Posted

Attached to
P130 COMMUNICATION STATION, NAS SIGONELLA, ITALY
Solicitation number
N6247020R4003
Issued by

About this file

This solicitation is for plumbing, waste and vent, and domestic water system upgrades at P130 Communication Station in Sigonella, Italy. The work includes replacing and installing new piping systems along with associated fixtures and equipment. The Naval Facilities Engineering Command is seeking bids for the project under solicitation number N6247020R4003. Offerors must submit proposals by the response date of July 15, 2020 and work will be awarded as a firm-fixed price contract. Veterans, HUBZone small businesses, small disadvantaged businesses, and women-owned small businesses will receive preference in evaluation.

View the file

Other files

File Type Posted
Amend 0004 08042020.pdf PDF
Amend 0003 07312020.pdf PDF
P130_Italian Safety Plan.pdf PDF
REVISED SPECIFICATION SECTION 01 30 01.00 20 (AMENDMENT 0002).pdf PDF
ATTACHMENT E REVISED SCHEDULE B PRICE PROPOSAL FORM DATED 07242020.pdf PDF
Amend 0002 07282020.pdf PDF
Attachment I - Photos - Site Locations.pdf PDF
Amend 0001 07142020.pdf PDF
Attachment E - Schedule B Price Proposal Form.pdf PDF
Attachment H - WO799152dwg11of35GENERALVOL02.pdf PDF
Attachment G - WO799152_spc_04of04.pdf PDF
Attachment A - Pre-Proposal Inquiry Form.xls XLS spreadsheet
Attachment H - WO799152dwg06of35CIVIL.pdf PDF
Attachment H - WO799152dwg09of35STRUCTURAL.pdf PDF
Attachment H - WO799152dwg07od35LANDSCAPE.pdf PDF
Attachment H - WO799152dwg34of35TELECOM.pdf PDF
Attachment H - WO799152dwg20of35INTERIORDESIGN.pdf PDF
Attachment H - WO799152dwg32of35ELECTRICAL.pdf PDF
Attachment H - WO799152dwg30of35GENERALVOL04.pdf PDF
Attachment H - WO799152dwg13of35ARCHITECTUREDEMO.pdf PDF
Attachment H - WO799152dwg01of35GENERALVOL01.pdf PDF
Attachment H - WO799152dwg26of35MECHANICAL.pdf PDF
Attachment H - WO799152dwg02of35GENERALVOL01.pdf PDF
Attachment H - WO799152dwg31of35ELECTRICAL.pdf PDF
Attachment H - WO799152dwg03of35HAZMAT.pdf PDF
Attachment H - WO799152dwg18of35ARCHITECTURE.pdf PDF
N6247020R4003 Solicitation.pdf PDF
Attachment H - WO799152dwg29of35GENERALVOL04.pdf PDF
Attachment G - WO799152_spc_01of04.pdf PDF
Attachment H - WO799152dwg19of35ARCHITECTURE.pdf PDF
Attachment H - WO799152dwg33of35ELECTRICAL.pdf PDF
Attachment H - WO799152dwg12of35ARCHITECTUREDEMO.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
Attachment H - WO799152dwg23of35GENERALVOL03.pdf PDF
Attachment H - WO799152dwg15of35ARCHITECTURE.pdf PDF
Attachment H - WO799152dwg27of35MECHANICAL.pdf PDF
Attachment H - WO799152dwg17of35ARCHITECTURE.pdf PDF
Attachment H - WO799152dwg21of35INTERIORDESIGN.pdf PDF
Attachment H - WO799152dwg16of35ARCHITECTURE.pdf PDF
Attachment H - WO799152dwg35o35TELECOM.pdf PDF
Attachment H - WO799152dwg08of35STRUCTURAL.pdf PDF
Attachment B - SEC-NAV_5512_1_11787 Form.pdf PDF
Attachment H - WO799152dwg04of35GEOTECHNICAL.pdf PDF
Attachment C - Construction and Design Experience Project Data Sheet.pdf PDF
Attachment H - WO799152dwg22of35GENERALVOL03.pdf PDF
Attachment H - WO799152dwg10of35GENERALVOL02.pdf PDF
Attachment H - WO799152dwg24of35FIREPROTECTION.pdf PDF
Attachment F - LRA Commercial Vehicle Inspection Procedures.pdf PDF
Attachment G - WO799152_spc_02of04.pdf PDF
Attachment H - WO799152dwg05of35CIVIL.pdf PDF
Show 40 more

Latest 50 of 53 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PLUMBING ABBREVIATIONS PLUMBING LEGEND GENERAL SHEET NOTES GENERAL SHEET NOTESPLUMBING ABBREVIATIONS

P-001

P

C

O M

M U

N

IC

A

TI

O N

S S

TA

TI

O N

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

ABBREVIAZIONI IMP. IDRAULICO ABBREVIAZIONI IMP. IDRAULICO LEGENDA IMP. IDRAULICO NOTE GENERALI TAVOLA NOTE GENERALI TAVOLA

AutoCAD SHX Text AC ADA AFF AFG AP BF BFP BV CO CONC CW DDC DN DWG DWH DWV DWBP EA EEW EL EQUIP ET EWC FCO FD FLA HB HC HW HWR HZ INV KPA KS L LAV LPM MAX MIN MS NC NO OB PH PRS

AutoCAD SHX Text ABOVE CEILING AMERICANS WITH DISABILITIES ACT ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ACCESS PANEL BELOW FLOOR BACKFLOW PREVENTER BALANCING VALVE CLEANOUT CONCRETE DOMESTIC COLD WATER DIRECT DIGITAL CONTROL DOWN DRAWING DOMESTIC WATER HEATER DRAIN, WASTE, VENT DOMESTIC WATER BOOSTER PUMP EACH EMERGENCY EYE WASH ELEVATION EQUIPMENT EXPANSION TANK ELECTRIC WATER COOLER FLOOR CLEANOUT FLOOR DRAIN FULL LOAD AMPS HOSE BIBB HANDICAP ACCESSIBLE DOMESTIC HOT WATER DOMESTIC HOT WATER RECIRC HERTZ INVERT ELEVATION KILOPASCAL KITCHEN SINK LITER LAVATORY LITERS PER MINUTE MAXIMUM MINIMUM MOP SINK NORMALLY CLOSED NORMALLY OPEN OUTLET BOX PHASE PRESSURE REDUCING STATION

AutoCAD SHX Text QTY REF RP RPM SAN SH SIM SR SS ST TMV TW TYP UON UR V VS VTR W WC WCO WH WHA WR WS °

AutoCAD SHX Text QUANTITY REFRIGERATOR RECIRCULATING PUMP REVOLUTIONS PER MINUTE SANITARY SHOWER SIMILAR SERVICE SINK SANITARY SEWER STORAGE TANK THERMOSTATIC MIXING VALVE TEPID WATER TYPICAL (TYP.) UNLESS OTHERWISE NOTED URINAL VENT VENT STACK VENT THRU ROOF WASTE WATER CLOSET WALL CLEANOUT WALL HYDRANT WATER HAMMER ARRESTOR INDIRECT WASTE RECEPTOR WASTE STACK DEGREE

AutoCAD SHX Text

LEGEND ABBREVATIONS GENERAL NOTES

AutoCAD SHX Text 14079694

AutoCAD SHX Text

AutoCAD SHX Text

BJF

AutoCAD SHX Text

BJF

AutoCAD SHX Text

SCE

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text

DEPARTMENT OF THE NAVY

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

CONSTR. CONTR. NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

NAVFAC METRIC DRAWFORM REVISION: 01 FEBRUARY 2017

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

NAVSTA SIGONELLA

AutoCAD SHX Text

SIGONELLA, ITALY

AutoCAD SHX Text 799152

AutoCAD SHX Text

AutoCAD SHX Text 06/25/2020

AutoCAD SHX Text

LET / JHR

AutoCAD SHX Text

CAPITAL IMPROVEMENTS

AutoCAD SHX Text

NORFOLK, VIRGINA

AutoCAD SHX Text

RICHARD STEPHENS, PE

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

DES PROD DIR

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

DPS

AutoCAD SHX Text

APPROVED BY DONALD OWENS (VIA EMAIL) NCTAMS N5 MILCON

AutoCAD SHX Text

SOPRA IL SOFFITTO

AutoCAD SHX Text

LEGGE "AMERICANI CON DISABILITÀ"

AutoCAD SHX Text

SOPRA IL PAVIMENTO FINITO

AutoCAD SHX Text

PANNELLO DI ACCESSO

AutoCAD SHX Text

SOTTO IL PAVIMENTO

AutoCAD SHX Text

DISPOSITIVO ANTIRIFLUSSO

AutoCAD SHX Text

VALVOLA DI BILANCIAMENTO

AutoCAD SHX Text

CHIUSINO

AutoCAD SHX Text

CALCESTRUZZO

AutoCAD SHX Text

QUANTITÀ

AutoCAD SHX Text

REFRIGERATORE

AutoCAD SHX Text

POMPA DI RICIRCOLO

AutoCAD SHX Text

GIRI AL MINUTO

AutoCAD SHX Text

SANITARIO

AutoCAD SHX Text

DOCCIA

AutoCAD SHX Text

SIMILE

AutoCAD SHX Text

VASCA DI SERVIZIO

AutoCAD SHX Text

FOGNATURA SANITARIA

AutoCAD SHX Text

COLONNA DI SCARICO

AutoCAD SHX Text

RECETTORE RIFIUTI INDIRETTI

AutoCAD SHX Text

DISPOSITIVO ARRESTO CORPO D'ARIETE

AutoCAD SHX Text

IDRANTE A PARETE

AutoCAD SHX Text

CHIUSINO A PARETE

AutoCAD SHX Text

WC

AutoCAD SHX Text

HERTZ

AutoCAD SHX Text

PROSPETTO/ELEVAZIONE INVERSO/A

AutoCAD SHX Text

KILOPASCAL

AutoCAD SHX Text

LAVANDINO CUCINA

AutoCAD SHX Text

LITRO

AutoCAD SHX Text

LAVATOIO

AutoCAD SHX Text

LITRO PER MINUTO

AutoCAD SHX Text

MASSIMO

AutoCAD SHX Text

MINIMO

AutoCAD SHX Text

LAVELLO

AutoCAD SHX Text

NORMALMENTE CHIUSO

AutoCAD SHX Text

NORMALMENTE APERTO

AutoCAD SHX Text

SCATOLA DI DERIVAZIONE

AutoCAD SHX Text

FASE

AutoCAD SHX Text

STAZIONE DI RIDUZIONE DELLA PRESSIONE

AutoCAD SHX Text

SERBATOIO STOCCAGGIO

AutoCAD SHX Text

VALVOLA MISCELATRICE TERMOSTATICA

AutoCAD SHX Text

ACQUA TIEPIDA

AutoCAD SHX Text

TIPICO

AutoCAD SHX Text

GRADO

AutoCAD SHX Text

SCARICO

AutoCAD SHX Text

SFIATO ATTRAVERSO IL TETTO

AutoCAD SHX Text

STAFFA DELLO SFIATO

AutoCAD SHX Text

SFIATO

AutoCAD SHX Text

URINATOIO

AutoCAD SHX Text

SALVO DIVERSA INDICAZIONE

AutoCAD SHX Text

ACQUA FREDDA DOMESTICA

AutoCAD SHX Text

CONTROLLO DIGITALE DIRETTO

AutoCAD SHX Text

GIÙ/ VERSO IL BASSO

AutoCAD SHX Text

DISEGNO/TAVOLA

AutoCAD SHX Text

SCALDABAGNO DOMESTICO

AutoCAD SHX Text

SCARICO, RIFIUTI, SCARICO

AutoCAD SHX Text

OGNI

AutoCAD SHX Text

LAVA OCCHI D'EMERGENZA

AutoCAD SHX Text

PROSPETTO

AutoCAD SHX Text

ATTREZZATURA

AutoCAD SHX Text

SERBATOIO DI ESPANSIONE

AutoCAD SHX Text

RAFFREDDATORE ELETTRICO DELL'ACQUA

AutoCAD SHX Text

CHIUSINO A PAVIMENTO

AutoCAD SHX Text

SCARICO A PAVIMENTO

AutoCAD SHX Text

CORRENTE A PIENO CARICO

AutoCAD SHX Text

RUBINETTO PER FLESSIBILE

AutoCAD SHX Text

ACCESSIBILE A DISABILI

AutoCAD SHX Text

ACQUA CALDA DOMESTICA

AutoCAD SHX Text

ACQUA CALDA DOMESTICA DI RICIRCOLO

AutoCAD SHX Text

1. THESE GENERAL PLUMBING NOTES APPLY TO PLUMBING DRAWINGS IN THESE GENERAL PLUMBING NOTES APPLY TO PLUMBING DRAWINGS IN THIS SET. SHEET SPECIFIC NOTES ARE INDICATED ON EACH SHEET UNDER GENERAL SHEET NOTES. 2. PROVIDE ALL EQUIPMENT PER MANUFACTURER'S INSTRUCTIONS. PROVIDE ALL EQUIPMENT PER MANUFACTURER'S INSTRUCTIONS. 3. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO PROVIDE COMPLETE AND OPERABLE PLUMBING SYSTEMS AS INDICATED ON THE DRAWINGS, SPECIFIED AND AS REQUIRED BY CODE. 4. PROVIDE PLUMBING FIXTURES AND EQUIPMENT WITH ACCESSIBLE PROVIDE PLUMBING FIXTURES AND EQUIPMENT WITH ACCESSIBLE STOPS. 5. FIELD VERIFY DIMENSIONS PRIOR TO PROCUREMENT AND FIELD VERIFY DIMENSIONS PRIOR TO PROCUREMENT AND INSTALLATION OF EQUIPMENT AND MATERIAL. 6. PROVIDE CLEANOUTS FULL SIZE OF PIPE. PROVIDE CLEANOUTS FULL SIZE OF PIPE. 7. COORDINATE PIPING WORK WITH OTHER TRADES. PROVIDE OFFSETS COORDINATE PIPING WORK WITH OTHER TRADES. PROVIDE OFFSETS IN PIPING AROUND OBSTRUCTIONS AT NO ADDITIONAL COST TO THE GOVERNMENT. 8. EXTEND PLUMBING VENTS WITHIN A 3000 RADIUS OF EXHAUST EXTEND PLUMBING VENTS WITHIN A 3000 RADIUS OF EXHAUST VENTS TO A HEIGHT OF 1M ABOVE EXHAUST VENT CROWN. 9. EXTEND PLUMBING VENTS WITHIN A 3000 RADIUS OF ANY EXTEND PLUMBING VENTS WITHIN A 3000 RADIUS OF ANY VENTILATION UNIT TO A HEIGHT OF 1000 ABOVE THE VENTILATION INTAKE. 10. MOUNT HOSE BIBBS 750 ABOVE FINISHED FLOOR UON. MOUNT HOSE BIBBS 750 ABOVE FINISHED FLOOR UON. 11. MOUNT WALL HYDRANTS 600 ABOVE FINISHED GRADE UON. MOUNT WALL HYDRANTS 600 ABOVE FINISHED GRADE UON. 12. ESTABLISH SLOPES AND INVERT ELEVATIONS OF INTERIOR PIPING ESTABLISH SLOPES AND INVERT ELEVATIONS OF INTERIOR PIPING BEFORE PIPING IS INSTALLED, SO THAT SLOPES WILL BE MAINTAINED. INSTALL PIPING TO AVOID CONFLICT WITH OTHER TRADES. 13. COORDINATE WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGHING-IN COORDINATE WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGHING-IN PLUMBING FIXTURES. 14. MAKE CODE-COMPLIANT HOT AND COLD WATER, HOT WATER MAKE CODE-COMPLIANT HOT AND COLD WATER, HOT WATER RECIRCULATING, WASTE, VENT, AND GAS, ETC PIPING CONNECTIONS TO ALL FIXTURES AND EQUIPMENT EVEN THOUGH ALL BRANCHES, FITTINGS AND CONNECTIONS ARE NOT SHOWN. 15. PROVIDE DEEP SEAL TRAPS FOR ALL FLOOR DRAINS. PROVIDE DEEP SEAL TRAPS FOR ALL FLOOR DRAINS. 16. PROVIDE EQUIPMENT, PLUMBING FIXTURES, TRIM HARDWARE AND/OR PROVIDE EQUIPMENT, PLUMBING FIXTURES, TRIM HARDWARE AND/OR DEVICES USUALLY UTILIZED IN THE CLASS OF WORK, THOUGH NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT WHICH MAY BE NECESSARY FOR THE SATISFACTORY COMPLETION OF THE WORK (AS DETERMINED BY THE CONTRACTING OFFICER). 17. PROVIDE MATERIALS AND EQUIPMENT WITH STAMPS OR SEALS OF PROVIDE MATERIALS AND EQUIPMENT WITH STAMPS OR SEALS OF ARI, ASME, UL, ASTM, CE OR ETL. 18. PERFORM TESTS FOR ACCEPTANCE AND APPROVAL BY CODE AND PERFORM TESTS FOR ACCEPTANCE AND APPROVAL BY CODE AND THE REQUIREMENTS OF APPLICABLE REGULATORY AGENCIES. PERFORM REQUIRED TESTS IN THE PRESENCE OF THE GOVERNMENT UNLESS OTHERWISE WAIVED IN WRITING. 19. COORDINATE WORK TO AVOID AND RESOLVE CONFLICTS PRIOR TO COORDINATE WORK TO AVOID AND RESOLVE CONFLICTS PRIOR TO PERFORMING WORK. 20. RUN PIPING CONCEALED ABOVE CEILING OR IN WALLS OR CHASES RUN PIPING CONCEALED ABOVE CEILING OR IN WALLS OR CHASES UNLESS OTHERWISE NOTED. RUN PIPING ABOVE CEILING TIGHT TO THE UNDERSIDE OF THE STRUCTURE, EXCEPT INSTALL COMPONENTS REQUIRING MAINTENANCE NO HIGHER THAN 3600 AFF. 21. LAYOUT OF PIPING IS DIAGRAMMATIC. RUN EXPOSED PIPING TIGHT LAYOUT OF PIPING IS DIAGRAMMATIC. RUN EXPOSED PIPING TIGHT TO THE STRUCTURE, UNLESS OTHERWISE NOTED. ALLOW FOR RISES, DROPS, AND OFFSETS AS REQUIRED. 22. SLOPE SANITARY SEWER PIPING DOWNWARD AT A MINIMUM 1,05%. SLOPE SANITARY SEWER PIPING DOWNWARD AT A MINIMUM 1,05%. 23. PROVIDE ACCESS PANELS IN WALLS AND HARD CEILINGS TO ACCESS PROVIDE ACCESS PANELS IN WALLS AND HARD CEILINGS TO ACCESS PLUMBING VALVES AND EQUIPMENT REQUIRING MAINTENANCE AND INSPECTION. ACCESS PANELS ARE NOT REQUIRED FOR WATER HAMMER ARRESTORS. 24. PROVIDE SEISMIC PROTECTION FOR PIPING AND EQUIPMENT IN PROVIDE SEISMIC PROTECTION FOR PIPING AND EQUIPMENT IN ACCORDANCE WITH THE SEISMIC DESIGN CRITERIA INDICATED ON STRUCTURAL DRAWING SHEET S-001. 25. AFTER THE PIPING IS INSULATED, PROVIDE FACTORY-FABRICATED AFTER THE PIPING IS INSULATED, PROVIDE FACTORY-FABRICATED PIPE LABELS ON THE FOLLOWING PIPING, AT 3000 ON CENTER ON LABELS ON THE FOLLOWING PIPING, AT 3000 ON CENTER ON THE PIPING MAINS AND 1500 ON CENTER ON THE BRANCH RUNOUTS FROM MAINS: HW DOMESTIC HOT WATER CW DOMESTIC COLD WATER HWR DOMESTIC HOT WATER RETURN RD ROOF DRAIN ROOF DRAIN ORD OVERFLOW/EMERGENCY ROOF DRAIN OVERFLOW/EMERGENCY ROOF DRAIN

AutoCAD SHX Text

DOMESTIC COLD WATER PIPING (CW)

AutoCAD SHX Text

DOMESTIC HOT WATER PIPING (HW)

AutoCAD SHX Text

SANITARY SEWER PIPING

AutoCAD SHX Text

VENT PIPING

AutoCAD SHX Text

CONDENSATE DRAIN PIPING

AutoCAD SHX Text

DOMESTIC HOT WATER RECIRC PIPING (HWR)

AutoCAD SHX Text

ROOF DRAIN PIPING

AutoCAD SHX Text

SS

AutoCAD SHX Text D

AutoCAD SHX Text V

AutoCAD SHX Text

(SEE SCHEDULE ON SHEET P-601)

AutoCAD SHX Text

(SEE PLUMBING SCHEDULES)

AutoCAD SHX Text

PLUMBING FIXTURE MARK

AutoCAD SHX Text

%%UP-1

AutoCAD SHX Text

PIPE TURNING DOWN

AutoCAD SHX Text

FLOOR DRAIN MARK WITH DEEP SEAL TRAP

AutoCAD SHX Text

CLEANOUT TO GRADE (COTG)

AutoCAD SHX Text

("X" = PDI SIZE)

AutoCAD SHX Text

WATER HAMMER ARRESTOR

AutoCAD SHX Text

VENT THRU ROOF (VTR)

AutoCAD SHX Text

EXTERIOR WALL HYDRANT (WH)

AutoCAD SHX Text

FLOOR CLEANOUT (FCO)

AutoCAD SHX Text

WALL CLEANOUT (WCO)

AutoCAD SHX Text

TEMPERATURE AND PRESSURE RELIEF VALVE

AutoCAD SHX Text

GATE VALVE (HORIZONTAL & VERTICAL)

AutoCAD SHX Text (X)

AutoCAD SHX Text

SHOWER DRAIN WITH DEEP SEAL TRAP

AutoCAD SHX Text

UNION

AutoCAD SHX Text

HOSE BIBB (HB)

AutoCAD SHX Text

CHECK VALVE

AutoCAD SHX Text

DOWNWARD SLOPE

AutoCAD SHX Text

(SEE PLUMBING SCHEDULES)

AutoCAD SHX Text

PLUMBING EQUIPMENT MARK

AutoCAD SHX Text

%%UDET-1

AutoCAD SHX Text

THERMOMETER IN PIPE WELL

AutoCAD SHX Text

MANUAL FLOW CONTROL BALANCING VALVE

AutoCAD SHX Text

BALL VALVE

AutoCAD SHX Text

RD

AutoCAD SHX Text

PIPE TURNING UP

AutoCAD SHX Text

PRESSURE/TEMPERATURE PORT

AutoCAD SHX Text

STRAINER

AutoCAD SHX Text

PIPE CAP

AutoCAD SHX Text

THERMOSTATIC MIXING VALVE

AutoCAD SHX Text

PIPING BELOW GRADE

AutoCAD SHX Text

REDUCER

AutoCAD SHX Text

FLEX CONNECTION

AutoCAD SHX Text

CONDOTTI ACQUA FREDDA DOMESTICA

AutoCAD SHX Text

CONDOTTI CALDA FREDDA DOMESTICA

AutoCAD SHX Text

CONDOTTI ACQUA CALDA DOMESTICA DI RICIRCOLO

AutoCAD SHX Text

CONDOTTI INTERRATI

AutoCAD SHX Text

TUBAZIONI FOGNATURA SANITARIA

AutoCAD SHX Text

TUBAZIONI SFIATO

AutoCAD SHX Text

CONDOTTI SCARICO CONDENSA

AutoCAD SHX Text

CONDOTTI SCARICO TETTO

AutoCAD SHX Text

PENDENZA VERSO IL BASSO

AutoCAD SHX Text

VALVOLA A SFERA

AutoCAD SHX Text

VALVOLA DI USCITA (ORIZZONT. & VERTIC.)

AutoCAD SHX Text

VALVOLA DI CONTROLLO

AutoCAD SHX Text

TERMOMETRO PER TUBAZIONE

AutoCAD SHX Text

TUBO DI USCITA

AutoCAD SHX Text

TUBO DI ENTRATA

AutoCAD SHX Text

TAPPO TUBAZIONE

AutoCAD SHX Text

TUBAZIONE PRESSIONE/TEMPERATURA

AutoCAD SHX Text

FILTRO

AutoCAD SHX Text

VALVOLA MISCELATORE TERMOSTATICO

AutoCAD SHX Text

RIDUTTORE

AutoCAD SHX Text

CONNESSIONE FLESSIBILE

AutoCAD SHX Text

VALVOLA DI SFIATO PRESSIONE E TEMPERATURA

AutoCAD SHX Text

VALVOLA DI BILANCIAMENTO CONTROLLO MANUALE DEL FLUSSO

AutoCAD SHX Text

UNIONE

AutoCAD SHX Text

IDRANTE A PARETE ESTERNO

AutoCAD SHX Text

RUBINETTO PER FLESSIBILE

AutoCAD SHX Text

SCARICO DOCCIA CON SIFONE

AutoCAD SHX Text

CHIUSINO A PARETE

AutoCAD SHX Text

CHIUSINO A PAVIMENTO

AutoCAD SHX Text

CHIUSINO A LIVELLO

AutoCAD SHX Text

DISPOSITIVO ARRESTO COLPO D'ARIETE ("X"= DIMENSIONI IN PDI)

AutoCAD SHX Text

ETICHETTA IMPIANTO IDRAULICO (VEDI ABACO IMPIANTO IDRAULICO)

AutoCAD SHX Text

ETICHETTA ATTREZZATURA IMP. IDRAULICO (VEDI ABACO IMPIANTO IDRAULICO)

AutoCAD SHX Text

ETICHETTA SCARICO A PAVIMENTO CON SIFONE (VEDI ABACO TAV. P-601)

AutoCAD SHX Text

OVERFLOW ROOF DRAIN PIPING

AutoCAD SHX Text

ORD

AutoCAD SHX Text

CONDOTTO SCARICO TETTO IN ECCESSO

AutoCAD SHX Text

SFIATO ATTRAVERSO IL TETTO

AutoCAD SHX Text

1. QUESTE NOTE GENERALI SULL'IDRAULICA SI RIFERISCONO AI DISEGNI QUESTE NOTE GENERALI SULL'IDRAULICA SI RIFERISCONO AI DISEGNI IDRAULICI DI QUESTO SET.LE NOTE DEL FOGLIO SONO INDICATE SU OGNI TAVOLA SOTTO LE NOTE GENERALI DELLA TAVOLA.

AutoCAD SHX Text

2. FORNIRE TUTTE LE APPARECCHIATURE SECONDO LE ISTRUZIONI DEL FORNIRE TUTTE LE APPARECCHIATURE SECONDO LE ISTRUZIONI DEL PRODUTTORE.

AutoCAD SHX Text

3. 3. FORNIRE TUTTI I MATERIALI E LE ATTREZZATURE ED ESEGUIRE 3. FORNIRE TUTTI I MATERIALI E LE ATTREZZATURE ED ESEGUIRE FORNIRE TUTTI I MATERIALI E LE ATTREZZATURE ED ESEGUIRE TUTTA LA MANODOPERA NECESSARIA PER FORNIRE SISTEMI IDRAULICI COMPLETI E FUNZIONANTI COME INDICATO NEI DISEGNI, SPECIFICATI E COME RICHIESTO DAL CODICE.

AutoCAD SHX Text

4. FORNIRE ATTREZZATURE E IMPIANTI IDRAULICI CON FERMATE FORNIRE ATTREZZATURE E IMPIANTI IDRAULICI CON FERMATE ACCESSIBILI.

AutoCAD SHX Text

5. VERIFICARE SUL CAMPO LE DIMENSIONI PRIMA VERIFICARE SUL CAMPO LE DIMENSIONI PRIMA DELL'APPROVVIGIONAMENTO E DELL'INSTALLAZIONE DI APPARECCHIATURE E MATERIALI.

AutoCAD SHX Text

6. FORNIRE LA DIMENSIONE DEI CLEANOUTS DEL TUBO.FORNIRE LA DIMENSIONE DEI CLEANOUTS DEL TUBO.

AutoCAD SHX Text

7. COORDINARE IL LAVORO DI CANALIZZAZIONE CON ALTRI SETTORI. COORDINARE IL LAVORO DI CANALIZZAZIONE CON ALTRI SETTORI. FORNIRE COMPENSAZIONI NELLE TUBAZIONI INTORNO AGLI OSTACOLI SENZA ALCUN COSTO AGGIUNTIVO PER IL GOVERNO.

AutoCAD SHX Text

8. ESTENDERE LE BOCCHETTE IDRAULICHE ENTRO UN RAGGIO DI 3000 ESTENDERE LE BOCCHETTE IDRAULICHE ENTRO UN RAGGIO DI 3000 DALLE BOCCHETTE DI SCARICO FINO AD UN'ALTEZZA DI 1 M SOPRA LA CORONA DELLA BOCCHETTA DI SCARICO.

AutoCAD SHX Text

9. ESTENDERE LE BOCCHETTE DELL'IMPIANTO IDRAULICO ENTRO UN ESTENDERE LE BOCCHETTE DELL'IMPIANTO IDRAULICO ENTRO UN RAGGIO DI 3000 DA QUALSIASI UNITÀ DI VENTILAZIONE AD UN'ALTEZZA DI 1000 SOPRA LA PRESA DI VENTILAZIONE.

AutoCAD SHX Text

10. MONTARE IL RUBINETTO PER IL TUBO FLESSIBILE 750 SOPRA IL MONTARE IL RUBINETTO PER IL TUBO FLESSIBILE 750 SOPRA IL PAVIMENTO FINITO SALVO DIVERSA INDICAZIONE

AutoCAD SHX Text

11. MONTARE IDRANTI A PARETE 600 SOPRA IL LIVELLO FINITO SALVO MONTARE IDRANTI A PARETE 600 SOPRA IL LIVELLO FINITO SALVO DIVERSA INDICAZIONE

AutoCAD SHX Text

12. STABILIRE LE PENDENZE E INVERTIRE L'ALTEZZA DELLE TUBAZIONI STABILIRE LE PENDENZE E INVERTIRE L'ALTEZZA DELLE TUBAZIONI INTERNE PRIMA DI INSTALLARE LE TUBAZIONI, IN MODO CHE LE PENDENZE SIANO MANTENUTE. INSTALLARE LE TUBAZIONI PER EVITARE CONFLITTI CON GLI ALTRI SETTORI.

AutoCAD SHX Text

13. COORDINARSI CON I DISEGNI ARCHITETTONICI PRIMA COSTRUIRE LE COORDINARSI CON I DISEGNI ARCHITETTONICI PRIMA COSTRUIRE LE BASI DEGLI IMPIANTI IDRAULICI.

AutoCAD SHX Text

14. EFFETTUARE COLLEGAMENTI CONFORMI AI CODICI PER ACQUA CALDA E EFFETTUARE COLLEGAMENTI CONFORMI AI CODICI PER ACQUA CALDA E FREDDA, RICIRCOLO DELL'ACQUA CALDA, RIFIUTI, SFIATO, GAS, ECC. A TUTTI GLI APPARECCHI E LE ATTREZZATURE, ANCHE SE NON VENGONO MOSTRATI TUTTI I RAMI, I RACCORDI E I COLLEGAMENTI.

AutoCAD SHX Text

15. FORNIRE SIFONI PER TUTTI GLI SCARICHI A PAVIMENTO.FORNIRE SIFONI PER TUTTI GLI SCARICHI A PAVIMENTO.

AutoCAD SHX Text

16. FORNIRE ATTREZZATURE, IMPIANTI IDRAULICI, HARDWARE DI RIFINITURA FORNIRE ATTREZZATURE, IMPIANTI IDRAULICI, HARDWARE DI RIFINITURA E/O DISPOSITIVI NORMALMENTE UTILIZZATI NELLA CLASSE DI LAVORO, ANCHE SE NON SPECIFICAMENTE MENZIONATI O INDICATI NEI DISEGNI, MA CHE POSSONO ESSERE NECESSARI PER IL COMPLETAMENTO SODDISFACENTE DEL LAVORO (COME DETERMINATO DAL COMMITTENTE)

AutoCAD SHX Text

17. FORNIRE MATERIALI E ATTREZZATURE CON TIMBRI O SIGILLI DI ARI, FORNIRE MATERIALI E ATTREZZATURE CON TIMBRI O SIGILLI DI ARI, ASME, UL, ASTM, CE O ETL.

AutoCAD SHX Text

18. ESEGUIRE PROVE PER L'ACCETTAZIONE E L'APPROVAZIONE IN BASE AL ESEGUIRE PROVE PER L'ACCETTAZIONE E L'APPROVAZIONE IN BASE AL CODICE E AI REQUISITI DELLE AGENZIE DI REGOLAMENTAZIONE APPLICABILI. ESEGUIRE I TEST RICHIESTI IN PRESENZA DEL GOVERNO, SALVO DIVERSA DEROGA SCRITTA.

AutoCAD SHX Text

19. COORDINARE IL LAVORO PER EVITARE E RISOLVERE I CONFLITTI PRIMA COORDINARE IL LAVORO PER EVITARE E RISOLVERE I CONFLITTI PRIMA DI SVOLGERE IL LAVORO.

AutoCAD SHX Text

20. PASSARE TUBAZIONI NASCOSTE SOPRA IL SOFFITTO O IN PARETI O PASSARE TUBAZIONI NASCOSTE SOPRA IL SOFFITTO O IN PARETI O SEGUIRE SALVO DIVERSA INDICAZIONE. LE TUBAZIONI DI SCORRIMENTO SOPRA IL SOFFITTO SONO A TENUTA STAGNA SUL LATO INFERIORE DELLA STRUTTURA, AD ECCEZIONE DELL'INSTALLAZIONE DI COMPONENTI CHE RICHIEDONO UNA MANUTENZIONE NON SUPERIORE A 3600 DAL PAVIMENTO FINITO.

AutoCAD SHX Text

21. LA DISPOSIZIONE DELLE TUBAZIONI È SCHEMATICA. ESEGUIRE LE LA DISPOSIZIONE DELLE TUBAZIONI È SCHEMATICA. ESEGUIRE LE TUBAZIONI A VISTA A STRETTO CONTATTO CON LA STRUTTURA, SALVO DIVERSA INDICAZIONE. CONSENTIRE ALZATE, ABBASSAMENTI E DISASSAMENTI SECONDO LE NECESSITÀ.

AutoCAD SHX Text

22. INCLINARE LE TUBAZIONI DELLE FOGNATURE SANITARIE VERSO IL INCLINARE LE TUBAZIONI DELLE FOGNATURE SANITARIE VERSO IL BASSO AD UN MINIMO DI 1,05%.

AutoCAD SHX Text

23. FORNIRE PANNELLI DI ACCESSO NELLE PARETI E NEI SOFFITTI RIGIDI FORNIRE PANNELLI DI ACCESSO NELLE PARETI E NEI SOFFITTI RIGIDI PER ACCEDERE ALLE VALVOLE IDRAULICHE E ALLE APPARECCHIATURE CHE RICHIEDONO MANUTENZIONE E ISPEZIONE. I PANNELLI DI ACCESSO NON SONO NECESSARI PER DISPOSITIVI DI ARRESTO COLPO D'ARIETE.

AutoCAD SHX Text

24. FORNIRE UNA PROTEZIONE SISMICA PER LE TUBAZIONI E LE FORNIRE UNA PROTEZIONE SISMICA PER LE TUBAZIONI E LE APPARECCHIATURE SECONDO I CRITERI DI PROGETTAZIONE SISMICA INDICATI SULLA TAVOLA STRUTTURALE S-001.

AutoCAD SHX Text

25. DOPO CHE LE TUBAZIONI SONO STATE ISOLATE, FORNIRE LE DOPO CHE LE TUBAZIONI SONO STATE ISOLATE, FORNIRE LE ETICHETTE DEI TUBI FABBRICATI SULLE SEGUENTI TUBAZIONI, A 3000 AL CENTRO SULLA RETE DI TUBAZIONI E A 1500 AL CENTRO SULLE DIRAMAZIONI DALLA RETE: HW ACQUA CALDA DOMESTICA CW ACQUA FREDDA DOMESTICA ACQUA FREDDA DOMESTICA HWR ACQUA CALDA DOMESTICA DI RICIRCOLO ACQUA CALDA DOMESTICA DI RICIRCOLO RD SCARICO TETTO SCARICO TETTO ORD SCARICO TETTO IN ECCESSOSCARICO TETTO IN ECCESSO

AutoCAD SHX Text

SOPRA IL TERRENO FINITO

AutoCAD SHX Text

POMPA PRESSURIZZAZIONE ACQUA SANITARIA

AutoCAD SHX Text

LEGENDA, ABBREVIAZIONI E NOTE GENERALI

P-101

P

C

O M

M U

N

IC

A

TI

O N

S S

TA

TI

O N

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

FIRST FLOOR WASTE & VENT PLAN - AREA A

GENERAL NOTES / NOTE GENERALI

KEY PLAN / PIANTA DI RIFERIMENTO

GRAPHIC SCALE / SCALA GRAFICA

NEW WORK KEY NOTES /

NOTE NUOVE LAVORAZIONI

UPS /

BATTERY

UPS /

BATTERY

SWITCHGEAR

ELEC.

STAIR

CORRIDOR

TELECOMM

MECHANICAL

N61 FILE

DRAWING

STORAGE

N61 MAINTENANCE

AREA

ANTENNA

SUPPORT

N9

ANTENNA

SUPPORT

N4

STORAGE 2

N61 EM POWER

TECHS

B

C

D

A

AutoCAD SHX Text

FIRST FLOOR WASTE & VENT PLAN - AREA A

AutoCAD SHX Text 14079695

AutoCAD SHX Text

AutoCAD SHX Text

BJF

AutoCAD SHX Text

BJF

AutoCAD SHX Text

SCE

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text

AutoCAD SHX Text 10m

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1:100

AutoCAD SHX Text

DEPARTMENT OF THE NAVY

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

CONSTR. CONTR. NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

NAVFAC METRIC DRAWFORM REVISION: 01 FEBRUARY 2017

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

NAVSTA SIGONELLA

AutoCAD SHX Text

SIGONELLA, ITALY

AutoCAD SHX Text 799152

AutoCAD SHX Text

AutoCAD SHX Text 06/25/2020

AutoCAD SHX Text

LET / JHR

AutoCAD SHX Text

CAPITAL IMPROVEMENTS

AutoCAD SHX Text

NORFOLK, VIRGINA

AutoCAD SHX Text

RICHARD STEPHENS, PE

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

DES PROD DIR

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

DPS

AutoCAD SHX Text

APPROVED BY DONALD OWENS (VIA EMAIL) NCTAMS N5 MILCON

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 1:100

AutoCAD SHX Text

MATCH LINE

AutoCAD SHX Text

REFER TO P-102

AutoCAD SHX Text

PLAN

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

1. LOCATE VENT PIPING ABOVE CEILING AND WITHIN PLUMBING WALL LOCATE VENT PIPING ABOVE CEILING AND WITHIN PLUMBING WALL CAVITIES/CHASES. LOCATE SANITARY PIPING WITHIN WALL CAVITIES/CHASES AND BELOW FLOOR SLAB, EXCEPT WHERE NOTED OTHERWISE. 2. SLOPE PIPING AT A MINIMUM OF 1-PERCENT SLOPE FOR SLOPE PIPING AT A MINIMUM OF 1-PERCENT SLOPE FOR DRAINAGE. SLOPE SANITARY UNDER FLOOR AT 2-PERCENT SLOPE.

AutoCAD SHX Text

1. DN100 SANITARY SEWER PIPING. SEE CIVIL DRAWINGS FOR DN100 SANITARY SEWER PIPING. SEE CIVIL DRAWINGS FOR CONTINUATION. 2. DN50 SANITARY SEWER PIPING. SEE CIVIL DRAWINGS FOR DN50 SANITARY SEWER PIPING. SEE CIVIL DRAWINGS FOR CONTINUATION. 3. DN50 SANITARY VENT PIPING UP THROUGH ROOF. DN50 SANITARY VENT PIPING UP THROUGH ROOF. 4. PROVIDE SUMP PUMP IN VAULT PIT. SEE SUMP PUMP DETAIL PROVIDE SUMP PUMP IN VAULT PIT. SEE SUMP PUMP DETAIL B4/P-501 AND PUMP SCHEDULE ON SHEET P-601. 5. PROVIDE FLOOR DRAIN FOR MECHANICAL EQUIPMENT CONDENSATE PROVIDE FLOOR DRAIN FOR MECHANICAL EQUIPMENT CONDENSATE DISCHARGE. COORDINATE EXACT LOCATION OF FLOOR DRAIN WITH MECHANICAL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION OF THE FLOOR DRAIN. 6. DN50 SANITARY VENT PIPING UP TO SECOND FLOOR. SEE SECOND DN50 SANITARY VENT PIPING UP TO SECOND FLOOR. SEE SECOND FLOOR PLUMBING PLAN - AREA A FOR CONTINUATION. 7. DN100 SANITARY SEWER PIPING DOWN FROM SECOND FLOOR. SEE DN100 SANITARY SEWER PIPING DOWN FROM SECOND FLOOR. SEE SECOND FLOOR PLUMBING PLAN - AREA A FOR CONTINUATION. 8. PROVIDE FLOOR DRAIN FOR BACKFLOW PREVENTER DISCHARGE. PROVIDE FLOOR DRAIN FOR BACKFLOW PREVENTER DISCHARGE. COORDINATE EXACT LOCATION OF THE FLOOR DRAIN WITH THE BACKFLOW RPEVENTER TO BE INSTALLED PRIOR TO INSTALLATION OF THE FLOOR DRAIN. 9. PROVIDE FLOOR CLEANOUT. SEE FLOOR CLEANOUT DETAIL PROVIDE FLOOR CLEANOUT. SEE FLOOR CLEANOUT DETAIL A4/P-501. 10. DN50 VENT PIPING UP FROM SUMP PUMP DISCHARGE PIPE TO DN50 VENT PIPING UP FROM SUMP PUMP DISCHARGE PIPE TO ABOVE FIRST FLOOR CEILING LEVEL. ROUTE PIPE ALONG FACE OF WALL AND PROVIDE REQUIRED PIPE SUPPORTS. 11. PROVIDE CLEANOUT TO GRADE. SEE CLEANOUT TO GRADE DETAIL PROVIDE CLEANOUT TO GRADE. SEE CLEANOUT TO GRADE DETAIL A4/P-502. 12. PROVIDE WALL CLEANOUT. SEE WALL CLEANOUT DETAIL B2/P-502. PROVIDE WALL CLEANOUT. SEE WALL CLEANOUT DETAIL B2/P-502.

AutoCAD SHX Text

1. INDIVIDUARE LE TUBAZIONI DELL'ACQUA FREDDA E CALDA E LE INDIVIDUARE LE TUBAZIONI DELL'ACQUA FREDDA E CALDA E LE TUBAZIONI DI SFIATO SOPRA IL SOFFITTO E ALL'INTERNO DELLE CAVITÀ/TRACCE DELLE PARETI IDRAULICHE. INDIVIDUARE LE TUBAZIONI SANITARIE ALL'INTERNO DI CAVITÀ/TRACCE DELLE PARETI E SOTTO LA SOLETTA DEL PAVIMENTO, SALVO DIVERSA INDICAZIONE.

AutoCAD SHX Text

/ SCALA: 1:100

AutoCAD SHX Text

1. DN100 TUBAZIONI PER FOGNATURE SANITARIE. VEDI DISEGNI CIVILI DN100 TUBAZIONI PER FOGNATURE SANITARIE. VEDI DISEGNI CIVILI PER LA CONTINUAZIONE.

AutoCAD SHX Text

2. DN50 TUBAZIONI PER FOGNATURE SANITARIE. VEDI DISEGNI CIVILI DN50 TUBAZIONI PER FOGNATURE SANITARIE. VEDI DISEGNI CIVILI PER LA CONTINUAZIONE.

AutoCAD SHX Text

3. DN50 TUBAZIONI DI SFIATO SANITARIO ATTRAVERSO IL TETTO.DN50 TUBAZIONI DI SFIATO SANITARIO ATTRAVERSO IL TETTO.

AutoCAD SHX Text

4. FORNIRE UNA POMPA A POZZETTO NEL POZZO DEL CAVEAU. FORNIRE UNA POMPA A POZZETTO NEL POZZO DEL CAVEAU. VEDERE IL DETTAGLIO DELLA POMPA DEL POZZETTO B4/P-501 E IL PROGRAMMA DELLE POMPE SUL FOGLIO P-601.

AutoCAD SHX Text

5. FORNIRE UNO SCARICO A PAVIMENTO PER LO SCARICO DI FORNIRE UNO SCARICO A PAVIMENTO PER LO SCARICO DI CONDENSA DELLE APPARECCHIATURE MECCANICHE. COORDINARE L'ESATTA POSIZIONE DELLO SCARICO A PAVIMENTO CON LE APPARECCHIATURE MECCANICHE DA INSTALLARE PRIMA DELL'INSTALLAZIONE DELLO SCARICO A PAVIMENTO.

AutoCAD SHX Text

6. DN50 TUBAZIONI DI SFIATO SANITARIO FINO AL SECONDO PIANO. DN50 TUBAZIONI DI SFIATO SANITARIO FINO AL SECONDO PIANO. VEDI SCHEMA IDRAULICO DEL SECONDO PIANO - AREA A PER LA CONTINUAZIONE.

AutoCAD SHX Text

7. DN100 TUBAZIONI DI SCARICO SANITARIO FINO AL SECONDO PIANO. DN100 TUBAZIONI DI SCARICO SANITARIO FINO AL SECONDO PIANO. VEDI SCHEMA IDRAULICO DEL SECONDO PIANO - AREA A PER LA CONTINUAZIONE.

AutoCAD SHX Text

2. LA PENDENZA DELLE TUBAZIONI AD UNA PENDENZA MINIMA DELL'1% LA PENDENZA DELLE TUBAZIONI AD UNA PENDENZA MINIMA DELL'1% PER IL DRENAGGIO. LA PENDENZA DEI TUBI DEI SANITARI SOTTO IL PAVIMENTO CON PENDENZA DEL 2%.

AutoCAD SHX Text

PIANTA PRIMO PIANO SCARICHI E SFIATI - AREA A

AutoCAD SHX Text

8. FORNIRE SCARICO A PAVIMENTO PER SCARICO DISPOSITIVO FORNIRE SCARICO A PAVIMENTO PER SCARICO DISPOSITIVO ANTIRIFLUSSO. COORDINARE L'ESATTA POSIZIONE DELLO SCARICO A PAVIMENTO CON IL DISP. ANTIRIFLUSSO DA INSTALLARE PRIMA DELL' INSTALLAZIONE DELLO SCARICO A PAVIMENTO.

AutoCAD SHX Text

9. FORNIRE CACCIATA A PAVIMENTO. VEDERE IL DETTAGLIO DELLA FORNIRE CACCIATA A PAVIMENTO. VEDERE IL DETTAGLIO DELLA CACCIATA A PAVIMENTO IN A4/P-501

AutoCAD SHX Text

10. TUBAZIONE DI SFIATO DN50 DAL TUBO DI SCARICO DELLA POMPA TUBAZIONE DI SFIATO DN50 DAL TUBO DI SCARICO DELLA POMPA DI AGGOTTAGGIO FINO A SOPRA IL LIVELLO DEL CONTROSOFFITTO AL PRIMO PIANO. INSTRADARE LA TUBAZIONE LUNGO LA SUPERFICIE DEL MURO E FORNIRE I SUPPORTI DELLA TUBAZIONE.

AutoCAD SHX Text

11. FORNIRE CACCIATA SU TERRENO. VEDERE DETTAGLIO CACCIATA SU FORNIRE CACCIATA SU TERRENO. VEDERE DETTAGLIO CACCIATA SU TERRENO IN A4/P-502

AutoCAD SHX Text

12. FORNIRE CACCIATA A PARETE. VEDERE IL DETTAGLIO DELLA FORNIRE CACCIATA A PARETE. VEDERE IL DETTAGLIO DELLA CACCIATA A PARETE IN B2/P-502

AutoCAD SHX Text

%%UEEW

AutoCAD SHX Text

%%UFD-1

AutoCAD SHX Text

%%UFD-1

AutoCAD SHX Text

%%UFD-1

AutoCAD SHX Text

%%UFCO

AutoCAD SHX Text

%%UEEW

AutoCAD SHX Text

%%UEWC-1

AutoCAD SHX Text

%%USP-3

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN50

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN50

AutoCAD SHX Text

DN50

AutoCAD SHX Text

DN50

AutoCAD SHX Text

DN50

AutoCAD SHX Text

DN50

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN50

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

%%UGCO

AutoCAD SHX Text

INV 23.60

AutoCAD SHX Text

%%UGCO

AutoCAD SHX Text

%%UFD-1

AutoCAD SHX Text

%%UFCO

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text V

AutoCAD SHX Text V

AutoCAD SHX Text V

AutoCAD SHX Text

DN50

AutoCAD SHX Text V

INV 23.46

P-102

C

O M

M U

N

IC

A

TI

O N

S S

TA

TI

O N

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

FIRST FLOOR WASTE & VENT PLAN - AREA B

GRAPHIC SCALE / SCALA GRAFICA

NEW WORK KEY NOTES / NOTE

NUOVE LAVORAZIONI

NEW WORK KEY NOTES / NOTE

NUOVE LAVORAZIONI

KEY PLAN / PIANTA DI RIFERIMENTO

GENERAL NOTES / NOTE GENERALI

CORRIDOR

N8 STORAGE

COMBINED

UNCLASSIFIED

WAREHOUSE (SMALL)

N8 NIPR

IMAGING

STAIR

N9

ANT MECH

SUPERVISOR

N9

ANT MECH

SUPERVISOR

CORRIDOR

N9

ANTENNA

SUPPORT

ELEVATOR

STORAGE

N8 LNSC

COMPUTER

TRAINING

CORRIDOR

SORTING

COMBINED

UNCLASSIFIED

WAREHOUSE (LARGE)

TELECOMM

ENTRY

STAIR

BREAK

ROOM

LOBBY

VESTIBULE

CORRIDOR

ELEC.

N1 CO

BUNK

N0

QUARTERDECK

N0 CCC

OFFICER LIBRARY

MECHANICAL

CORRIDOR

N8

OPEN

OFFICE

N4

STORAGE

N4 MULTIMEDIA

ROOM

B

C

A

AutoCAD SHX Text

FIRST FLOOR WASTE & VENT PLAN - AREA B

AutoCAD SHX Text 14079696

AutoCAD SHX Text

AutoCAD SHX Text

BJF

AutoCAD SHX Text

BJF

AutoCAD SHX Text

SCE

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text

AutoCAD SHX Text 10m

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1:100

AutoCAD SHX Text

DEPARTMENT OF THE NAVY

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

CONSTR. CONTR. NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

NAVFAC METRIC DRAWFORM REVISION: 01 FEBRUARY 2017

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

NAVSTA SIGONELLA

AutoCAD SHX Text

SIGONELLA, ITALY

AutoCAD SHX Text 799152

AutoCAD SHX Text

AutoCAD SHX Text 06/25/2020

AutoCAD SHX Text

LET / JHR

AutoCAD SHX Text

CAPITAL IMPROVEMENTS

AutoCAD SHX Text

NORFOLK, VIRGINA

AutoCAD SHX Text

RICHARD STEPHENS, PE

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

DES PROD DIR

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

DPS

AutoCAD SHX Text

APPROVED BY DONALD OWENS (VIA EMAIL) NCTAMS N5 MILCON

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 1:100

AutoCAD SHX Text

REFER TO P-101

AutoCAD SHX Text

MATCHLINE

AutoCAD SHX Text

MATCH LINE

AutoCAD SHX Text

REFER TO P-103

AutoCAD SHX Text

PLAN

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

/ SCALA: 1:100

AutoCAD SHX Text

1. DN100 SANITARY SEWER PIPING. SEE CIVIL DRAWINGS FOR DN100 SANITARY SEWER PIPING. SEE CIVIL DRAWINGS FOR CONTINUATION. 2. PROVIDE FLOOR DRAIN UNDER RAISED ACCESS FLOORING. PROVIDE FLOOR DRAIN UNDER RAISED ACCESS FLOORING. COORDINATE EXACT LOCATION OF FLOOR DRAIN WITH FLOORING SYSTEM TO BE INSTALLED PRIOR TO INSTALLATION OF THE FLOOR DRAIN. 3. PROVIDE SUMP PUMP IN VAULT PIT. SEE SUMP PUMP DETAIL PROVIDE SUMP PUMP IN VAULT PIT. SEE SUMP PUMP DETAIL B4/P-501 AND PUMP SCHEDULE ON SHEET P-601. 4. PROVIDE DN50 SANITARY VENT PIPING UP TO SECOND FLOOR. SEE PROVIDE DN50 SANITARY VENT PIPING UP TO SECOND FLOOR. SEE SECOND FLOOR WASTE & VENT PLAN - AREA B FOR CONTINUATION.

AutoCAD SHX Text

1. DN100 TUBAZIONI PER FOGNATURE SANITARIE. VEDI TAVOLE CIVILI DN100 TUBAZIONI PER FOGNATURE SANITARIE. VEDI TAVOLE CIVILI PER LA CONTINUAZIONE.

AutoCAD SHX Text

2. FORNIRE UNO SCARICO A PAVIMENTO SOTTO IL PAVIMENTO DI ACCESSO SOPRAELEVATO. COORDINARE LA POSIZIONE ESATTA DELLO SCARICO A PAVIMENTO CON IL SISTEMA DI PAVIMENTO DA INSTALLARE PRIMA DELL'INSTALLAZIONE DELLO SCARICO A PAVIMENTO.

AutoCAD SHX Text

3. FORNIRE UNA POMPA A POZZETTO NEL POZZO DEL CAVEAU. FORNIRE UNA POMPA A POZZETTO NEL POZZO DEL CAVEAU. VEDERE IL DETTAGLIO DELLA POMPA DEL POZZETTO B4/P-501 E IL PROGRAMMA DELLE POMPE SULLA TAVOLA P-601.

AutoCAD SHX Text

4. FORNIRE LE TUBAZIONI DI SFIATO SANITARIO DN50 FINO AL FORNIRE LE TUBAZIONI DI SFIATO SANITARIO DN50 FINO AL SECONDO PIANO. VEDI SCHEMA IDRAULICO DEL SECONDO PIANO - AREA B PER LA CONTINUAZIONE.

AutoCAD SHX Text

1. LOCATE VENT PIPING ABOVE CEILING AND WITHIN PLUMBING WALL LOCATE VENT PIPING ABOVE CEILING AND WITHIN PLUMBING WALL CAVITIES/CHASES. LOCATE SANITARY PIPING WITHIN WALL CAVITIES/CHASES AND BELOW FLOOR SLAB, EXCEPT WHERE NOTED OTHERWISE. 2. SLOPE PIPING AT A MINIMUM OF 1-PERCENT SLOPE FOR DRAINAGE. SLOPE PIPING AT A MINIMUM OF 1-PERCENT SLOPE FOR DRAINAGE. SLOPE SANITARY UNDER FLOOR AT 2-PERCENT SLOPE.

AutoCAD SHX Text

1. INDIVIDUARE LE TUBAZIONI DELL'ACQUA FREDDA E CALDA E LE INDIVIDUARE LE TUBAZIONI DELL'ACQUA FREDDA E CALDA E LE TUBAZIONI DI SFIATO SOPRA IL SOFFITTO E ALL'INTERNO DELLE CAVITÀ/TRACCE DELLE PARETI IDRAULICHE. INDIVIDUARE LE TUBAZIONI SANITARIE ALL'INTERNO DI CAVITÀ/TRACCE DELLE PARETI E SOTTO LA SOLETTA DEL PAVIMENTO, SALVO DIVERSA INDICAZIONE.

AutoCAD SHX Text

2. LA PENDENZA DELLE TUBAZIONI AD UNA PENDENZA MINIMA DELL'1% LA PENDENZA DELLE TUBAZIONI AD UNA PENDENZA MINIMA DELL'1% PER IL DRENAGGIO. LA PENDENZA DEI TUBI DEI SANITARI SOTTO IL PAVIMENTO CON PENDENZA DEL 2%.

AutoCAD SHX Text

PIANTA PRIMO PIANO SCARICHI E SFIATI - AREA B

AutoCAD SHX Text

5. PROVIDE FLOOR DRAIN FOR MECHANICAL EQUIPMENT CONDENSATE PROVIDE FLOOR DRAIN FOR MECHANICAL EQUIPMENT CONDENSATE DRAINAGE. COORDINATE EXACT LOCATION OF FLOOR DRAIN WITH MECHANICAL EQUIPMENT TO BE INSTALLED PRIOR TO INSTALLATION OF THE FLOOR DRAIN. 6. DN50 SANITARY VENT PIPING SERVING MECHANICAL ROOM FLOOR DN50 SANITARY VENT PIPING SERVING MECHANICAL ROOM FLOOR DRAIN UP FROM BELOW FLOOR TO ABOVE CEILING LEVEL ALONG FACE OF MECHANICAL ROOM WALL. 7. DN80 ROOF DRAIN PIPING AND DN80 OVERFLOW ROOF DRAIN DN80 ROOF DRAIN PIPING AND DN80 OVERFLOW ROOF DRAIN PIPING DOWN IN CHASE FROM SECOND FLOOR. SEE SECOND FLOOR WASTE & VENT PLAN - AREA B FOR CONTINUATION. 8. DN80 ROOF DRAIN PIPING DOWN FROM ROOF DRAIN ON ROOF. SEE DN80 ROOF DRAIN PIPING DOWN FROM ROOF DRAIN ON ROOF. SEE SECOND FLOOR WASTE & VENT PLAN - AREA B FOR CONTINUATION. 9. DN80 OVERFLOW ROOF DRAIN PIPING DOWN FROM OVERFLOW ROOF DN80 OVERFLOW ROOF DRAIN PIPING DOWN FROM OVERFLOW ROOF DRAIN ON ROOF. SEE SECOND FLOOR WASTE & VENT PLAN - AREA B FOR CONTINUATION. 10. DN80 ROOF DRAIN PIPING AND DN80 OVERFLOW ROOF DRAIN DN80 ROOF DRAIN PIPING AND DN80 OVERFLOW ROOF DRAIN PIPING DOWN FROM SECOND FLOOR. SEE SECOND FLOOR WASTE & VENT PLAN - AREA B FOR CONTINUATION. 11. SANITARY SEWER PIPING LOCATED ABOVE FIRST FLOOR CEILING. SANITARY SEWER PIPING LOCATED ABOVE FIRST FLOOR CEILING. 12. PROVIDE CLEANOUT TO GRADE. SEE CLEANOUT TO GRADE DETAIL PROVIDE CLEANOUT TO GRADE. SEE CLEANOUT TO GRADE DETAIL A4/P-502. 13. DN50 SANITARY SEWER PIPING DOWN FROM SECOND FLOOR. SEE DN50 SANITARY SEWER PIPING DOWN FROM SECOND FLOOR. SEE SECOND FLOOR WASTE AND VENT PLAN - AREA B FOR CONTINUATION. 14. DN100 SANITARY SEWER PIPING DOWN FROM SECOND FLOOR. SEE DN100 SANITARY SEWER PIPING DOWN FROM SECOND FLOOR. SEE SECOND FLOOR WASTE AND VENT PLAN - AREA B FOR CONTINUATION. 15. SANITARY SEWER PIPING DOWN IN FIRST FLOOR WALL FROM ABOVE SANITARY SEWER PIPING DOWN IN FIRST FLOOR WALL FROM ABOVE FIRST FLOOR CEILING TO BELOW SLAB. 16. SANITARY SEWER PIPING DOWN IN FIRST FLOOR CHASE FROM SANITARY SEWER PIPING DOWN IN FIRST FLOOR CHASE FROM ABOVE FIRST FLOOR CEILING TO BELOW SLAB. 17. SANITARY SEWER DOWN FROM SECOND FLOOR. ROUTE ABOVE FIRST SANITARY SEWER DOWN FROM SECOND FLOOR. ROUTE ABOVE FIRST FLOOR CEILING AND THEN DOWN IN FIRST FLOOR WALL TO BELOW SLAB. 18. PROVIDE WALL CLEANOUT. SEE WALL CLEANOUT DETAIL B2/P-502. PROVIDE WALL CLEANOUT. SEE WALL CLEANOUT DETAIL B2/P-502. 19. PROVIDE FLOOR CLEANOUT. SEE FLOOR CLEANOUT DETAIL PROVIDE FLOOR CLEANOUT. SEE FLOOR CLEANOUT DETAIL A4/P-501. 20. DN50 VENT UP FROM SUMP PUMP DISCHARGE PIPE TO ABOVE DN50 VENT UP FROM SUMP PUMP DISCHARGE PIPE TO ABOVE FIRST FLOOR CEILING LEVEL. 21. PROVIDE SUMP PUMP IN ELEVATOR PIT. SEE SUMP PUMP DETAIL PROVIDE SUMP PUMP IN ELEVATOR PIT. SEE SUMP PUMP DETAIL B4/P-501 AND PUMP SCHEDULE ON SHEET P-601. 22. PROVIDE CLEANOUT AT END OF PIPING. SEE END-OF-PIPING PROVIDE CLEANOUT AT END OF PIPING. SEE END-OF-PIPING CLEANOUT DETAIL D4/P-501.

AutoCAD SHX Text

5. FORNIRE UNO SCARICO A PAVIMENTO PER LO SCARICO DI FORNIRE UNO SCARICO A PAVIMENTO PER LO SCARICO DI CONDENSA DELLE APPARECCHIATURE MECCANICHE. COORDINARE L'ESATTA POSIZIONE DELLO SCARICO A PAVIMENTO CON LE APPARECCHIATURE MECCANICHE DA INSTALLARE PRIMA DELL'INSTALLAZIONE DELLO SCARICO A PAVIMENTO.

AutoCAD SHX Text

6. DN50 TUBAZIONI DI SFIATO SANITARIO CHE SERVONO LO SCARICO DN50 TUBAZIONI DI SFIATO SANITARIO CHE SERVONO LO SCARICO MECCANICO A PAVIMENTO DEL LOCALE DA SOTTO IL PAVIMENTO FINO A SOPRA IL LIVELLO DEL CONTROSOFFITTO LUNGO LA FACCIA DELLA PARETE DEL LOCALE MECCANICO.

AutoCAD SHX Text

8. TUBAZIONI DN80 DI DRENAGGIO DEL TETTO DALLO SCARICO SULLA TUBAZIONI DN80 DI DRENAGGIO DEL TETTO DALLO SCARICO SULLA COPERTURA. VEDERE LA PIANTA SECONDO PIANO SCARICHI E SFIATI - AREA B PER LA CONTINUAZIONE.

AutoCAD SHX Text

10. TUBAZIONI DN80 DI DRENAGGIO DEL TETTO E TUBAZIONI DN80 DI TUBAZIONI DN80 DI DRENAGGIO DEL TETTO E TUBAZIONI DN80 DI DRENAGGIO DEL TETTO DEL TROPPOPIENO DAL SECONDO PIANO. VEDERE LA PIANTA SECONDO PIANO SCARICHI E SFIATI - AREA B PER LA CONTINUAZIONE.

AutoCAD SHX Text

11. TUBAZIONE DELLA FOGNATURA SANITARIA POSIZIONATA SOPRA IL TUBAZIONE DELLA FOGNATURA SANITARIA POSIZIONATA SOPRA IL CONTROSOFFITTO DEL PRIMO PIANO

AutoCAD SHX Text

12. FORNIRE LA CACCIATA DAL LIVELLO. VEDERE IL DETTAGLIO DELLA FORNIRE LA CACCIATA DAL LIVELLO. VEDERE IL DETTAGLIO DELLA CACCIATA DAL LIVELLO A4/P-502

AutoCAD SHX Text

13. TUBAZIONE DN50 DELLA FOGNATURA SANITARIA DAL SECONDO TUBAZIONE DN50 DELLA FOGNATURA SANITARIA DAL SECONDO PIANO.

AutoCAD SHX Text

14. TUBAZIONE DN100 DELLA FOGNATURA SANITARIA DAL SECONDO TUBAZIONE DN100 DELLA FOGNATURA SANITARIA DAL SECONDO PIANO. VEDERE LA PIANTA SECONDO PIANO SCARICHI E SFIATI - AREA B PER LA CONTINUAZIONE.

AutoCAD SHX Text

15. TUBAZIONE DELLA FOGNATURA SANITARIA NEL MURO PRIMO PIANO TUBAZIONE DELLA FOGNATURA SANITARIA NEL MURO PRIMO PIANO DA SOPRA IL CONTROSOFFITTO DEL PRIMO PIANO VERSO LA PARTE INFERIORE DELLA SOLETTA

AutoCAD SHX Text

16. TUBAZIONE DELLA FOGNATURA SANITARIA NEL CAVEDIO DEL PRIMO TUBAZIONE DELLA FOGNATURA SANITARIA NEL CAVEDIO DEL PRIMO PIANO DA SOPRA IL CONTROSOFFITTO DEL PRIMO PIANO FINO A SOTTO IL SOLAIO.

AutoCAD SHX Text

17. TUBAZIONE DELLA FOGNATURA SANITARIA DAL SECONDO PIANO. TUBAZIONE DELLA FOGNATURA SANITARIA DAL SECONDO PIANO. INSTRADARE SOPRA IL CONTROSOFFITTO DEL PRIMO PIANO E POI GIÙ NEL MURO DEL PRIMO PIANO FINO A SOTTO IL SOLAIO.

AutoCAD SHX Text

18. FORNIRE LA CACCIATA A PARETE. VEDI IL DETTAGLIO DELLA FORNIRE LA CACCIATA A PARETE. VEDI IL DETTAGLIO DELLA CACCIATA A PARETE B2/P-502.

AutoCAD SHX Text

19. FORNIRE CACCIATA A PAVIMENTO. VEDERE IL DETTAGLIO DELLA FORNIRE CACCIATA A PAVIMENTO. VEDERE IL DETTAGLIO DELLA CACCIATA A PAVIMENTO A4/P-501

AutoCAD SHX Text

20. SFIATO DN50 DAL TUBO DI SCARICO DELLA POMPA DI AGGOTTAGGIO SFIATO DN50 DAL TUBO DI SCARICO DELLA POMPA DI AGGOTTAGGIO FINO A SOPRA IL LIVELLO DEL CONTROSOFFITTO DEL PRIMO PIANO.

AutoCAD SHX Text

21. FORNIRE POMPA DI AGGOTTAGGIO NELLA FOSSA DELL'ASCENSORE. FORNIRE POMPA DI AGGOTTAGGIO NELLA FOSSA DELL'ASCENSORE. VEDERE DETTAGLIO DELLA POMPA DI AGGOTTAGGIO IN B4/P-501 E TABELLA POMPE SULLA TAVOLA P-601

AutoCAD SHX Text

22. PREVEDERE UNA CACCIATA ALLA FINE DELLA TUBAZIONE. VEDERE PREVEDERE UNA CACCIATA ALLA FINE DELLA TUBAZIONE. VEDERE DETTAGLIO DELLA CACCIATA ALLA FINE DELLA TUBAZIONE IN D4/P-501

AutoCAD SHX Text

9. TUBAZIONI DN80 DI DRENAGGIO DEL TETTO DAL TROPPOPIENO TUBAZIONI DN80 DI DRENAGGIO DEL TETTO DAL TROPPOPIENO DELLO SCARICO SULLA COPERTURA. VEDERE LA PIANTA SECONDO PIANO SCARICHI E SFIATI - AREA B PER LA CONTINUAZIONE.

AutoCAD SHX Text

7. TUBAZIONI DN80 DI DRENAGGIO DEL TETTO E TUBAZIONI DN80 DI TUBAZIONI DN80 DI DRENAGGIO DEL TETTO E TUBAZIONI DN80 DI DRENAGGIO DEL TETTO A SFIORO GIÙ NEL CAVEDIO DAL SECONDO PIANO. VEDERE LA PIANTA SECONDO PIANO SCARICHI E SFIATI - AREA B PER LA CONTINUAZIONE.

AutoCAD SHX Text

%%UFD-1

AutoCAD SHX Text

%%UFCO

AutoCAD SHX Text

%%UFCO

AutoCAD SHX Text

%%UFCO

AutoCAD SHX Text

%%UFD-1

AutoCAD SHX Text

%%UFD-1

AutoCAD SHX Text

%%UFD-1

AutoCAD SHX Text

%%USP-1

AutoCAD SHX Text

%%UKS-1

AutoCAD SHX Text

%%US-1

AutoCAD SHX Text

%%UCO

AutoCAD SHX Text

%%UCO

AutoCAD SHX Text A1

AutoCAD SHX Text P-401

AutoCAD SHX Text

%%UCO

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN50

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN40

AutoCAD SHX Text

DN80

AutoCAD SHX Text

DN80

AutoCAD SHX Text

DN100

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN50

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

%%UGCO

AutoCAD SHX Text

DN50

AutoCAD SHX Text

DN50

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text

SS

AutoCAD SHX Text

ORD

AutoCAD SHX Text

RD

AutoCAD SHX Text

ORD

AutoCAD SHX Text

RD

AutoCAD SHX Text

ORD

AutoCAD SHX Text

RD

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text V

AutoCAD SHX Text V

AutoCAD SHX Text V

AutoCAD SHX Text V

AutoCAD SHX Text

ORD

AutoCAD SHX Text

RD

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text

DN50

AutoCAD SHX Text

DN100

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN100

AutoCAD SHX Text

%%USP-2

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN000

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN100

AutoCAD SHX Text

DN100

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text

%%UWCO

AutoCAD SHX Text V

AutoCAD SHX Text

DN80

AutoCAD SHX Text

DN80

AutoCAD SHX Text

DN100

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

AutoCAD SHX Text

SS

INV 23.72

P-103

C

O M

M U

N

IC

A

TI

O N

S S

TA

TI

O N

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

FIRST FLOOR WASTE & VENT PLAN - AREA C

KEY PLAN / PIANTA DI RIFERIMENTO

GRAPHIC SCALE / SCALA GRAFICA

NEW WORK KEY NOTES / NOTE

NUOVE LAVORAZIONI

GENERAL NOTES / NOTE GENERALI

N8

OPEN

OFFICE

N4 MULTIMEDIA

ROOM

OFFICE

STAIR

STORAGE

OFFICE

N8 LNSC

TECH

DIR

N8

LNSC

LCPO

B

C

D

A

AutoCAD SHX Text

FIRST FLOOR WASTE & VENT PLAN - AREA C

AutoCAD SHX Text 14079697

AutoCAD SHX Text

AutoCAD SHX Text

BJF

AutoCAD SHX Text

BJF

AutoCAD SHX Text

SCE

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text

AutoCAD SHX Text 10m

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1:100

AutoCAD SHX Text

DEPARTMENT OF THE NAVY

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

CONSTR. CONTR. NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

NAVFAC METRIC DRAWFORM REVISION: 01 FEBRUARY 2017

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

NAVSTA SIGONELLA

AutoCAD SHX Text

SIGONELLA, ITALY

AutoCAD SHX Text 799152

AutoCAD SHX Text

AutoCAD SHX Text 06/25/2020

AutoCAD SHX Text

LET / JHR

AutoCAD SHX Text

CAPITAL IMPROVEMENTS

AutoCAD SHX Text

NORFOLK, VIRGINA

AutoCAD SHX Text

RICHARD STEPHENS, PE

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

DES PROD DIR

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

DPS

AutoCAD SHX Text

APPROVED BY DONALD OWENS (VIA EMAIL) NCTAMS N5 MILCON

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 1:100

AutoCAD SHX Text

PLAN

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

REFER TO P-102

AutoCAD SHX Text

MATCHLINE

AutoCAD SHX Text

1. DN150 ROOF DRAIN PIPING TO STORM SEWER. SEE CIVIL DRAWINGS DN150 ROOF DRAIN PIPING TO STORM SEWER. SEE CIVIL DRAWINGS FOR CONTINUATION. 2. DN150 OVERFLOW ROOF DRAIN PIPING DOWN TO APPROXIMATELY DN150 OVERFLOW ROOF DRAIN PIPING DOWN TO APPROXIMATELY 900 AFG AND CONNECT TO OVERFLOW DOWNSPOUT NOZZLE MOUNTED TO FACE TO EXTERIOR WALL. SEE OVERFLOW DOWNSPOUT NOZZLE DETAIL C4/A-501. 3. DN80 ROOF DRAIN PIPING AND DN80 OVERFLOW ROOF DRAIN DN80 ROOF DRAIN PIPING AND DN80 OVERFLOW ROOF DRAIN PIPING DOWN FROM SECOND FLOOR. SEE SECOND FLOOR WASTE & VENT PLAN - AREA B FOR CONTINUATION. 4. PIPING LOCATED ABOVE FIRST FLOOR CEILING. PIPING LOCATED ABOVE FIRST FLOOR CEILING. 5. SANITARY SEWER PIPING DOWN FROM FIXTURE LOCATED ON SECOND SANITARY SEWER PIPING DOWN FROM FIXTURE LOCATED ON SECOND FLOOR. SEE SECOND FLOOR WASTE AND VENT PLAN - AREA C FOR CONTINUATION. 6. PROVIDE CLEANOUT TO GRADE. SEE CLEANOUT TO GRADE DETAIL PROVIDE CLEANOUT TO GRADE. SEE CLEANOUT TO GRADE DETAIL A4/P-502. 7. ROUTE ROOF DRAIN PIPING DOWN IN CHASE FROM ABOVE FIRST ROUTE ROOF DRAIN PIPING DOWN IN CHASE FROM ABOVE FIRST FLOOR CEILING TO BELOW SLAB. ROUTE OVERFLOW ROOF DRAINING DOWN IN CHASE FROM ABOVE FIRST FLOOR CEILING TO APPROXIMATELY 900 AFG FOR CONNECTION TO DOWNSPOUT NOZZLE. 8. DN100 SANITARY SEWER PIPING DOWN FROM SECOND FLOOR TO DN100 SANITARY SEWER PIPING DOWN FROM SECOND FLOOR TO ABOVE FIRST FLOOR CEILING. 9. PROVIDE CLEANOUT AT END OF PIPING. SEE END-OF-PIPING PROVIDE CLEANOUT AT END OF PIPING. SEE END-OF-PIPING CLEANOUT DETAIL D4/P-501.

AutoCAD SHX Text

/ SCALA: 1:100

AutoCAD SHX Text

1. DN150 TUBATURE DI SCARICO SUL TETTO PER LE FOGNATURE. VEDI DN150 TUBATURE DI SCARICO SUL TETTO PER LE FOGNATURE. VEDI DISEGNI CIVILI PER LA CONTINUAZIONE.

AutoCAD SHX Text

2. DN150 TUBO DI DRENAGGIO A SFIORO PER TETTI FINO A CIRCA DN150 TUBO DI DRENAGGIO A SFIORO PER TETTI FINO A CIRCA 900 DI PROFONDITÀ E COLLEGARE AL BOCCHETTONE A SFIORO MONTATO DI FRONTE ALLA PARETE ESTERNA. VEDERE IL DETTAGLIO DELL'UGELLO A SFIORO SULLA TAVOLA C4/A-501.

AutoCAD SHX Text

3. DN80 TUBO DI SCARICO PER TETTI E DN80 TUBO DI SCARICO PER DN80 TUBO DI SCARICO PER TETTI E DN80 TUBO DI SCARICO PER TETTI A SFIORO DAL SECONDO PIANO. VEDI SCHEMA IDRAULICO DEL SECONDO PIANO - AREA B PER LA CONTINUAZIONE.

AutoCAD SHX Text

PIANTA PRIMO PIANO SCARICHI E SFIATI - AREA C

AutoCAD SHX Text

1. LOCATE VENT PIPING, ROOF DRAIN PIPING, AND OVERFLOW ROOF LOCATE VENT PIPING, ROOF DRAIN PIPING, AND OVERFLOW ROOF DRAIN PIPING ABOVE CEILING AND WITHIN PLUMBING WALL CAVITIES/CHASE. LOCATE SANITARY PIPING WITHIN WALL CAVITIES/CHASES AND BELOW FLOOR SLAB, EXCEPT WHERE NOTED OTHERWISE. 2. SLOPE PIPING AT A MINIMUM OF 1-PERCENT SLOPE FOR SLOPE PIPING AT A MINIMUM OF 1-PERCENT SLOPE FOR DRAINAGE. SLOPE SANITARY UNDER FLOOR AT 2-PERCENT SLOPE.

AutoCAD SHX Text

1. INDIVIDUARE LE TUBAZIONI DELL'ACQUA FREDDA E CALDA E LE INDIVIDUARE LE TUBAZIONI DELL'ACQUA FREDDA E CALDA E LE TUBAZIONI DI SFIATO SOPRA IL SOFFITTO E ALL'INTERNO DELLE CAVITÀ/TRACCE DELLE PARETI IDRAULICHE. INDIVIDUARE LE TUBAZIONI SANITARIE ALL'INTERNO DI CAVITÀ/TRACCE DELLE PARETI E SOTTO LA SOLETTA DEL PAVIMENTO, SALVO DIVERSA INDICAZIONE.

AutoCAD SHX Text

2. LA PENDENZA DELLE TUBAZIONI AD UNA PENDENZA MINIMA DELL'1% LA PENDENZA DELLE TUBAZIONI AD UNA PENDENZA MINIMA DELL'1% PER IL DRENAGGIO. LA PENDENZA DEI TUBI DEI SANITARI SOTTO IL PAVIMENTO CON PENDENZA DEL 2%.

AutoCAD SHX Text

4. TUBAZIONE DELLA FOGNA SANITARIA POSIZIONATA SOPRA IL TUBAZIONE DELLA FOGNA SANITARIA POSIZIONATA SOPRA IL CONTROSOFFITTO AL PRIMO PIANO

AutoCAD SHX Text

5. LA TUBAZIONE DELLA FOGNA GIÙ DALL'IMPIANTO POSIZIONATO AL LA TUBAZIONE DELLA FOGNA GIÙ DALL'IMPIANTO POSIZIONATO AL SECONDO PIANO. VEDERE LA PIANTA SECONDO PIANO SCARICHI E SFIATI - AREA C PER LA CONTINUAZIONE.

AutoCAD SHX Text

6. FORNIRE CACCIATA SU TERRENO. VEDERE DETTAGLIO CACCIATA SU FORNIRE CACCIATA SU TERRENO. VEDERE DETTAGLIO CACCIATA SU TERRENO IN A4/P-502

AutoCAD SHX Text

7. INSTRADARE LA TUBAZIONE DI SCARICO DAL TETTO GIÙ INSTRADARE LA TUBAZIONE DI SCARICO DAL TETTO GIÙ NELL'INTERCAPEDINE DA SOPRA IL CONTROSOFFITTO AL PRIMO PIANO FINO A SOTTO IL SOLAIO. INSTRADARE LO SCARICO DEL TROPPOPIENO DEL TETTO NELL'INTERCAPEDINE DA SOPRA IL CONTROSOFFITTO AL PRIMO PIANO FINO A 900 DI PROFONDITA' DAL TERRENO FINITO PER LA CONNESSIONE ALLA BOCCHETTA DEL PLUVIALE

AutoCAD SHX Text

8. TUBAZIONE DN100 DELLA FOGNA SANITARIA GIÙ DAL SECONDO TUBAZIONE DN100 DELLA FOGNA SANITARIA GIÙ DAL SECONDO PIANO FINO A SOPRA IL CONTROSOFFITTO DEL PRIMO PIANO

AutoCAD SHX Text

9. PREVEDERE UNA CACCIATA ALLA FINE DELLA TUBAZIONE. VEDERE PREVEDERE UNA CACCIATA ALLA FINE DELLA TUBAZIONE. VEDERE DETTAGLIO DELLA CACCIATA ALLA FINE DELLA TUBAZIONE IN D4/P-501

AutoCAD SHX Text

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .