Attachment E ACM Testing Report.pdf
PDF 3 MB Posted
- Attached to
- Replace Roofs on Campus Federal contract opportunity
- Solicitation number
- 36C26223B0007
About this file
This document contains an asbestos testing report and details of a federal contract solicitation to replace roofs on a VA campus. The asbestos testing report analyzes samples from roofs on the VA hospital and finds chrysotile asbestos in flashing materials. The solicitation seeks bids to replace roofs across the campus in Albuquerque, New Mexico for the VA New Mexico Healthcare System with a project value between $5-10 million. The work includes general construction, roofing replacement, alterations, mechanical and electrical work. The contract will be set aside for Service-Disabled Veteran-Owned Small Businesses and must be listed in the SBA VetCert database. The NAICS code is 236220 for commercial and institutional building construction up to $45 million. The point of contact is Steven Covell who can be reached by email.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Responses RFIs 43_ 54 VA Reroofs 501_19_100.docx | DOCX document | |
| 36C26223B0007 0003.pdf | ||
| REVISED SHEETS_BLDGS 1_14_39_45_46.pdf | ||
| 36C26223B0007 0002.pdf | ||
| RFIs 1_ 42 VA Reroofs 501_149_100 _ Addendum 01.pdf | ||
| REVISED SHEETS_BLDG_1_BLDG_45_BLDG_46.pdf | ||
| Pages 31_60 from 00 _ ABQ PV Drawing.pdf | ||
| Pages 1_30 from 00 _ ABQ PV Drawing.pdf | ||
| Pages 61_95 from 00 _ ABQ PV Drawing.pdf | ||
| VA Roofing 501-19-100_General Spec Manual_FINAL-UPDATD.pdf | ||
| Amendment 0001 36C26223B0007.pdf | ||
| Attachment A Specifications.pdf | ||
| Solicitation 36C26223B0007.pdf | ||
| Attachment B Drawings.pdf | ||
| Attachment C Wage Determination.pdf | ||
| Attachment D Bid Schedule.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
♦ EMSL Analytical, Inc.
200 Route 130 North Cinnaminson, NJ 08077
Tel/Fax: (800) 220-3675 I (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
Attention: William Biava
Assaigai LLC
PO Box 90430
Albuquerque, NM 87199-0430
Project: VA Hospital Complex Bldg 1
EMSL Order: 042005935
Customer ID: AALl63
Customer PO: A56811-1
Project ID: 501-19-100
Phone: (505) 217-0333
Fax: (505) 345-7259
Received Date: 03/04/2020 9:30 AM
Analysis Date: 03/07/2020
Collected Date:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description
1-Fiberboard Level #4 - West Roof
- Fiberboard
042005935-0001
1-Tar Level #4 - West Roof -Tar
042005935-0001A
2-Fiberboard Level #4 - Northeast Roof - Fiberboard
042005935-0002
2-Tar Level #4 - Northeast Roof - Tar
042005935-0002A
3 Level #3 - Northeast Roof - Fiberboard
042005935-0003
4 Level #4 - West Roof
- Parapet Flashing
042005935-0004
5 Level #3 - Northeast Roof - Parapet
042005935-0005 Flashing
6 Level #3 Southwest Roof - Parapet
042005935-0006 Flashing
Analyst(s) Rachel Irwin (8)
Non-Asbestos
Appearance % Fibrous
Brown 80% Cellulose Fibrous Homogeneous Black Non-Fibrous Homogeneous Brown 60% Cellulose Fibrous Homogeneous Black Non-Fibrous Homogeneous Brown 60% Cellulose Fibrous Homogeneous Black Non-Fibrous Homogeneous Black Non-Fibrous Homogeneous Black Non-Fibrous Homogeneous
% Non-Fibrous
20% Non-fibrous (Other)
100% Non-fibrous (Other)
40% Non-fibrous (Other)
100% Non-fibrous (Other)
40% Non-fibrous (Other)
92% Non-fibrous (Other)
92% Non-fibrous (Other)
92% Non-fibrous (Other)
Asbestos
% Type
None Detected
None Detected
None Detected
None Detected
None Detected
8% Chrysotile
8% Chrysotile
8% Chrysotile
Samantha Rundstrom, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim
Method"), but augmented with procedures outlined in the 1993 Pinal") version of the method. This report relates only to the samples repcrted above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . Interpretation and use of test results are the responsibility of the client. All samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. EMSL recommends gravimetric reduction for all non-friable organically bound materials prior to analysis. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Cinnaminson. NJ NVLAP Lab Code 101048-0. Al HA-LAP, LLC-IHLAP Lab 100194, NYS ELAP 10872, NJ DEP 03036, PA ID# 68-00367, LA #04127
( Initial report from: 03/07/2020 10:57:45
ASB_PLM_000B_0001 • 1. 78 Printed: 3/7/2020 10:57 AM Page 1 of 1