This document outlines a federal solicitation for roof replacement services at the VA New Mexico Healthcare System campus in Albuquerque, New Mexico. The solicitation seeks to "Replace Roofs on Campus" and will procure all necessary supervision, labor, materials, equipment, and transportation to accomplish the work. The scope includes general construction, roofing replacement, alterations, mechanical and electrical work, utility systems, necessary demolition and removal of existing structures. All work must be performed according to the solicitation terms and conditions, specifications, drawings, and applicable local and VA building codes. This procurement is set aside as a 100% SDVOSB requirement and contractors must be verified in the VetCert database. The NAICS code is 236220 for Commercial and Institutional Building Construction with a size standard of $45 million. The estimated value of this construction project is between $5 million and $10 million. Interested parties should contact the contracting specialist, Steven J. Covell, at the email provided.

View the file

Other files for this federal contract opportunity

Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HSS 6"x4"x`1|8`" WELDED

BOTTOM CHORD

HSS 14"x6"x`3|16̀" WELDED

COLUMN ASSEMBLY

HSS 14"x6"x`3|16̀" WELDED

COLUMN ASSEMBLY

2" SQ 11GA

TRUSS STRUT

(2) `3|8`" x 1" LONG HEX HEAD

CAP SCREW, w/ AVK KNURLED

THREADED INSERT (TYP. FOR ALL

PURLIN CONNECTIONS)

15 x 7" x `3|8`"

POST TOP PLATE

HSS 6"x4"x`1|8`" WELDED

TOP CHORD

FORMED APEX GUSSET

`1|4`" THK

FORMED 10GA

PURLIN CLIP

FORMED 10GA

PURLIN CLIP

(8) `3|4`" X 6" GRADE 5 BOLTS PER EA.

TOP CHORD

CONNECTION

`1|4`" THK. FORMED BOTTOM

CHORD CLIP - EACH SIDE

(4) `3|4`" X 6" GRADE 5 BOLTS PER EA.

BOTTOM

CHORD CONNECTION

2" SQ 11GA

TRUSS STRUT

FORMED APEX GUSSET

`1|4`" THK

SOLAR RACKING ALUMINUM

RAIL SYSTEM

(8) `3|4`" X 6" GRADE 5 BOLTS PER EA.

TOP CHORD

CONNECTION

HSS 6"x4"x`1|8`" WELDED

TOP CHORD

`3|8`" x 1" LONG HEX HEAD

CAP SCREW, w/ AVK KNURLED

THREADED INSERT (TYP. FOR ALL

L-FOOT CONNECTIONS)

HSS 6"x4"x`1|8`" WELDED

BOTTOM CHORD

(4) `3|4`" X 6" GRADE 5 BOLTS PER EA.

BOTTOM

CHORD CONNECTION

HSS 14"x6"x`3|16̀" WELDED

COLUMN ASSEMBLY

`1|4`" THK. FORMED BOTTOM

CHORD CLIP

`1|4`" THK. FORMED BOTTOM

CHORD CLIP

VA REVIEW COMMENTS1 03/29/11

PNM REVIEW COMMENTS2 10/30/11

FINAL AS-BUILTS3 02/29/12

VA REVIEW COMMENTS1 03/29/11

PNM REVIEW COMMENTS2 10/30/11

FINAL AS-BUILTS3 02/29/12

HSS 6"x4"x`1|8`" WELDED

BOTTOM CHORD

HSS 14"x6"x`5|16̀" WELDED

COLUMN ASSEMBLY

HSS 14"x6"x`5|16̀" WELDED

COLUMN ASSEMBLY

2" SQ 11GA

TRUSS STRUT

(2) `3|8`" x 1" LONG HEX HEAD

CAP SCREW, w/ AVK KNURLED

THREADED INSERT (TYP. FOR ALL

PURLIN CONNECTIONS)

15 x 7" x `3|8`"

POST TOP PLATE

HSS 6"x4"x`3|16̀" WELDED

TOP CHORD

FORMED APEX GUSSET

`1|4`" THK

FORMED 10GA

PURLIN CLIP

(2) `3|8`" x 1" LONG HEX HEAD

CAP SCREW, `w|̀ AVK KNURLED

THREADED INSERT (TYP. FOR ALL

PURLIN CONNECTIONS)

FORMED 10GA

PURLIN CLIP

(8) `3|4`" X 6" GRADE 5 BOLTS PER EA.

TOP CHORD

CONNECTION

`1|4`" THK. FORMED BOTTOM

CHORD CLIP

(4) `3|4`" X 6" GRADE 5 BOLTS PER EA.

BOTTOM

CHORD CONNECTION

2" SQ 11GA

TRUSS STRUT

FORMED APEX GUSSET

`1|4`" THK

SOLAR RACKING ALUMINUM

RAIL SYSTEM

(8) `3|4`" X 6" GRADE 5 BOLTS PER EA.

TOP CHORD

CONNECTION

HSS 6"x4"x`3|16̀" WELDED

TOP CHORD

HSS 6"x4" WELDED

TOP CHORD

6"x4" TUBE PURLIN

(REF SHT 1.0)

10GA FORMED PURLIN

BRACKET

`3|8`" x 1" LONG HEX HEAD

CAP SCREW, w/ AVK KNURLED

THREADED INSERT (TYP. FOR ALL

L-FOOT CONNECTIONS)

HSS 6"x4"x`1|8`" WELDED

BOTTOM CHORD

HSS 14"x6"x`1|4`" WELDED

COLUMN ASSEMBLY

`1|4`" THK. FORMED BOTTOM

CHORD CLIP - EACH SIDE

(4) `3|4`" X 6" GRADE 5

BOLTS PER EA. BOTTOM

CHORD CONNECTION

VA REVIEW COMMENTS1 03/29/11

PNM REVIEW COMMENTS2 10/30/11

FINAL AS-BUILTS3 02/29/12

VA REVIEW COMMENTS1 03/29/11

PNM REVIEW COMMENTS2 10/30/11

FINAL AS-BUILTS3 02/29/12