ATTACHMENT B Final Inventory.xlsx
XLSX spreadsheet 48 KB Posted
- Attached to
- 33330225RF0010015 - Indefinite Delivery/Indefinite Quantity SI Wide Boiler Services Contract
- Solicitation number
- 33330225RF0010015
- Issued by
-
Smithsonian Institution
About this file
This is a final inventory spreadsheet detailing boiler assets across multiple Smithsonian Institution facilities. The comprehensive document lists 90+ boilers located at various sites including Suitland, Reynolds Center, Renwick Gallery, SERC, NASM-Dulles, NMAAHC, NMAH, Freer Gallery, Cooper Hewitt, Anacostia Community Museum, National Museum of the American Indian, and the National Zoo. The boilers are categorized by location, building, brand (including A.O. Smith, Fulton, Cleaver Brooks, RBI, and Weil-McLain), model numbers, serial numbers, condition ratings (ranging from 2-Poor to 5-Excellent), and in-service dates spanning from 1992 to 2024.
The inventory corresponds directly with a related federal contract opportunity (Solicitation Number: 33330225RF0010015) for an Indefinite Delivery/Indefinite Quantity (IDIQ) Boiler Services Contract. The solicitation seeks a contractor to provide preventive and remedial maintenance services for these boilers across Smithsonian facilities in Washington DC, New York City, Suitland, Edgewater, Chantilly, and Front Royal. The contract will have a 12-month base period with nine optional additional periods, targeting NAICS codes 238220 (Plumbing, Heating, and Air-Conditioning Contractors) and 221330 (Steam and Air-conditioning Supply).
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Copy of Smithsonian Equipment Revision 2018 Boilers.xlsx | XLSX spreadsheet | |
| Boilers Location and Equipment Information List 1 Final.pdf | ||
| 33330225RF0010015 Amend 0004.pdf | ||
| 33330225RF0010015 Amend 0003.pdf | ||
| 33330225RF0010015 POOOO2.pdf | ||
| 33330225RF0010015 Amendment 0001.pdf | ||
| ATTACHMENT H SI-707.pdf | ||
| 33330225RF0010015 Final.pdf | ||
| ATTACHMENT G SD419.pdf | ||
| ATTACHMENT D OCon_520.doc | DOC document | |
| ATTACHMENT C Tririga Usage Section 5.30.24.docx | DOCX document | |
| ATTACHMENT F Confined space permit.xlsx | XLSX spreadsheet | |
| ATTACHMENT E Hot Work Permit (Daily) NEW.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Suitland
| *Anything in Red needs to be either added into Tririga or has is in Tririga, but would not pull up on the inventory due to its CSI code (ie a pump and not a boiler) | |||||||||
| Asset ID | Property | Building | Catalog Name | Local Name | Brand | Model Number | Serial Number | Condition | In Service Date |
| 120903 | Garber-Suitland | Boiler- Steam Natural Gas | Garber Boiler (Natural Gas) | A.O. Smith | FCG75300 | 5 - Excellent | |||
| 120904 | Garber-Suitland | Building 29 | Boiler- Steam Natural Gas | Garber Natural Gas Boiler | Ruud | R92PA0851521MSA | 5 - Excellent | ||
| 50741 | MSC-Suitland | Osteo Prep Laboratory | Heating Boilers | Steam Boiler | Smith Cast Iron Boilers | 94-19036 H-10215 | 3 - Fair | 06/11/2008 | |
| 53018 | MSC-Suitland | Museum Support Center | Heating Boilers | Boiler 2 | Fulton | VMP130 | 101578 | 4 - Good | 06/11/2008 |
| 53019 | MSC-Suitland | Museum Support Center | Heating Boilers | Boiler 1 | Fulton | VMP130 | 101589 | 3 - Fair | 06/11/2008 |
| 103423 | MSC-Suitland | HSD Greenhouse | Boiler- Electric | B-1 | RBI | MB 1250 | 0910301783 | 4 - Good | 04/17/2000 |
| 104407 | MSC-Suitland | Museum Support Center | Heating Boilers | Boilers HOA | Fulton | ST 300 | 21321 | 4 - Good | 04/17/2000 |
| 119792 | MSC-Suitland | Museum Support Center | Fire-Tube Boilers | Boiler #1 | Cleaver Brooks | 4WG-200-250-150# | T4257-1-1 | 4 - Good | 01/01/2015 |
| 119793 | MSC-Suitland | Museum Support Center | Fire-Tube Boilers | Boiler #2 | Cleaver Brooks | 4WG-200-250-150ST | T4257-1-3 | 4 - Good | 01/01/2015 |
| 119794 | MSC-Suitland | Museum Support Center | Fire-Tube Boilers | Boiler # 3 | Cleaver Brooks | 4WG-200-250-150# | T4257-1-3 | 4 - Good | 01/01/2015 |
| 1053030/50375 | NMAI-CRC (Suitland) | NMAI Cultural Resource Center | Heating Boilers | BOILER 1 | Hurtz | 5-Excellent | 12/01/2020 |
Gallery Plac
| *Anything in Red needs to be either added into Tririga or has is in Tririga, but would not pull up on the inventory due to its CSI code (ie a pump and not a boiler) | |||||||||
| Asset ID | Property | Building | Catalog Name | Local Name | Brand | Model Number | Serial Number | Condition | In Service Date |
| 120908 | Reynolds Center | D. W. Reynolds Center | Boiler- Steam Natural Gas | DWRC Boiler 1 | RBI | 101675186 | 5 - Excellent | 03/01/2016 | |
| 120909 | Reynolds Center | D. W. Reynolds Center | Boiler- Steam Natural Gas | DWRC Boiler 2 | RBI | 71674355 | 5 - Excellent | 03/01/2016 | |
| 120910 | Reynolds Center | D. W. Reynolds Center | Boiler- Steam Natural Gas | DWRC Boiler 3 | RBI | 011672952 | 5 - Excellent | 03/01/2016 | |
| 120911 | Reynolds Center | D. W. Reynolds Center | Boiler- Steam Natural Gas | DWRC Boiler 4 | RBI | 121572751 | 5 - Excellent | 03/01/2016 | |
| 120912 | Reynolds Center | D. W. Reynolds Center | Boiler- Steam Natural Gas | DWRC Boiler 5 | RBI | 101675200 | 5 - Excellent | 03/01/2016 | |
| 120913 | Reynolds Center | D. W. Reynolds Center | Boiler- Steam Natural Gas | DWRC Boiler 6 | RBI | 081674598 | 5 - Excellent | 03/01/2016 | |
| 120914 | Reynolds Center | D. W. Reynolds Center | Boiler- Steam Natural Gas | DWRC Boiler 7 | RBI | 011672664 | 5 - Excellent | 03/01/2016 | |
| 120915 | Reynolds Center | D. W. Reynolds Center | Boiler- Steam Natural Gas | DWRC Boiler 8 | RBI | 011673006 | 5 - Excellent | 03/01/2016 | |
| 113652 | Renwick | Renwick Gallery | Water Heater- Natural Gas | Boiler # 1 | LAARS | 4-Good | 01/01/2014 | ||
| 113653 | Renwick | Renwick Gallery | Water Heater-Natural Gas | Boiler #2 | LAARS | 4-Good | 01/01/2014 | ||
| 113654 | Renwick | Renwick Gallery | Water Heater- Natural Gas | Boiler #3 | LAARS | 4-Good | 01/01/2014 |
SERC
| *Anything in Red needs to be either added into Tririga or is in Tririga, but would not pull up on the inventory due to its CSI code (ie a pump and not a boiler) | |||||||||
| Asset ID | Property | Building | Catalog Name | Local Name | Brand | Model Number | Serial Number | Condition | In Service Date |
| 81209 | SERC-Main | Charles Mathias Laboratory | Boiler- Electric | Boiler - B-1 | BRYAN | 165BH4T6 | 99111 | 5 - Excellent | 01/01/2013 |
| 117155 | SERC-Main | Main Building | Hot Water Heater | FHP #1 (HWH) | 4 - Good | 01/01/2012 | |||
| 117156 | SERC-Main | Main Building | Hot Water Heater | FHP #2 (HWH) | 4 - Good | 01/01/2012 | |||
| 117157 | SERC-Main | Main Building | Hot Water Heater | FHP #3 (HWH) | 4 - Good | 01/01/2012 | |||
| 117158 | SERC-Main | Main Building | Hot Water Heater | FHP #4 (HWH) | 4 - Good | 01/01/2012 | |||
| 117159 | SERC-Main | Main Building | Hot Water Heater | FHP #5 (HWH) | 4 - Good | 01/01/2012 | |||
| 117160 | SERC-Main | Main Building | Hot Water Heater | FHP #6 (HWH) | 4 - Good | 01/01/2012 | |||
| 117161 | SERC-Main | Main Building | Hot Water Heater | FHP #7 (HWH) | 4 - Good | 01/01/2012 | |||
| 117162 | SERC-Main | Main Building | Hot Water Heater | FHP #8 (HWH) | 4 - Good | 01/01/2012 | |||
| 117163 | SERC-Main | Main Building | Hot Water Heater | FHP #9 (HWH) | 4 - Good | 01/01/2012 | |||
| 117164 | SERC-Main | Main Building | Hot Water Heater | FHP #10 (HWH) | 4 - Good | 01/01/2012 | |||
| 117165 | SERC-Main | Main Building | Hot Water Heater | FHP #11 (HWH) | 4 - Good | 01/01/2012 | |||
| 117166 | SERC-Main | Main Building | Hot Water Heater | FHP #12 (HWH) | 4 - Good | 01/01/2012 | |||
| SERC-Main | Administration Building | Boiler (oil fired) | Burnham | 3- Fair | 01/01/2006 | ||||
| SERC-Main | Manor House | Boiler (oil fired) | Columbia | 3- Fair | 01/01/2006 | ||||
| 111938 | SERC-Main | Schmidt Building | Furnace # | 3- Fair | 1/1/11 | ||||
| 111939 | SERC-Main | Schmidt Building | Furnace # | 3- Fair | 1/1/11 | ||||
| 111940 | SERC-Main | Schmidt Building | Furnace # | 3- Fair | 1/1/11 | ||||
| 111941 | SERC-Main | Schmidt Building | Furnace # | 3- Fair | 1/1/11 | ||||
| 80507 | SERC-Main | Maintenance Shop | Heating Boilers | Boiler Bldg 120 | Burnham | 3- Fair | 01/01/2006 | ||
| SERC-Main | Administration Building | Boiler (oil fired) | Burnham | 3-Fair | 01/01/2006 | ||||
| SERC-Main | Manor House | Boiler (oil fired) | Columbia | 3-Fair | 01/01/2006 |
EMZ
| *Anything in Red needs to be either added into Tririga or has is in Tririga, but would not pull up on the inventory due to its CSI code (ie a pump and not a boiler). Yellow highlights are changes to Tririga. | |||||||||
| Asset ID | Property | Building | Catalog Name | Local Name | Brand | Model Number | Serial Number | Condition | In Service Date |
| 21200 | NASM-Dulles | Udvar-Hazy Center | Boiler- Steam Oil/Gas/Comb | STB-1 | Superior | 4-5-2007 | 14945 | 2-Fair | 11/21/2006 |
| 21201 | NASM-Dulles | Udvar-Hazy Center | Boiler- Steam Oil/Gas/Comb | STB-2 | Superior | 4-5-2007 | 14944 | 2-Fair | 11/21/2006 |
| 21202 | NASM-Dulles | Udvar-Hazy Center | Boiler- Steam Oil/Gas/Comb | STB-3 | Superior | 4-5-1027 | 14940 | 2-Fair | 11/21/2006 |
| 1000744 | NASM-Dulles | Udvar-Hazy Center | Condensing Boilers | B-G-01 | Cleaver Brooks | CFC-700-1000 | 16010100110385 | 4- Very Good | 01/22/2019 |
| 1000745 | NASM-Dulles | Udvar-Hazy Center | Condensing Boilers | B-G-02 | Cleaver Brooks | CFC-700-1000 | 16010100110391 | 4- Very Good | 01/22/2019 |
| 21212 | NASM-Dulles | Udvar-Hazy Center | Clean Steam Generator | CSG-1 | RECO. USA | 25111 | T-17001 | 2-Fair | 01/01/2003 |
| 112501 | NASM-Dulles | Udvar-Hazy Center | Gas water Heater | GWH-1 | PVI Industries, LLC | 8TPL | 609127351 | 3 - Good | 07/01/1905 |
| 111679 | NASM-Dulles | Udvar-Hazy Center | Gas water Heater | GWH-2 | PVI Industries, LLC | 8TPL | 6609127352 | 3 - Good | 07/01/1905 |
| FM03846 | NASM-MALL | National Air & Space Museum | Condensing Boiler | B-1 | Fulton | VTG-4000 | F2075952A | 5 - Excellent | 03/01/2024 |
| FM03847 | NASM-MALL | National Air & Space Museum | Condensing Boiler | B-2 | Fulton | VTG-4001 | F2076249A | 5 - Excellent | 03/01/2024 |
| FM03848 | NASM-MALL | National Air & Space Museum | Condensing Boiler | B-3 | Fulton | VTG-4002 | F2076291A | 5 - Excellent | 03/01/2024 |
| FM03849 | NASM-MALL | National Air & Space Museum | Condensing Boiler | B-4 | Fulton | VTG-4003 | F2076335A | 5 - Excellent | 03/01/2024 |
WMZ
| *Anything in Red needs to be either added into Tririga or has is in Tririga, but would not pull up on the inventory due to its CSI code (ie a pump and not a boiler) | |||||||||
| Asset ID | Property | Building | Catalog Name | Local Name | Brand | Model Number | Serial Number | Condition | In Service Date |
| FM04742 | NMAH\National | National Museum of American History | Boiler-Steam Unfired | Steam Generator West Interior | CEMLINE Corporation | V24OUSG2036 | 67066 | 3 - Fair | 01/01/2015 |
| 117950 | NMAAHC | National Museum of African American History & Culture | Condensing Boilers | CB-1 | Fulton | VTG-4000LE | 3-Fair | 06/08/2016 | |
| 117951 | NMAAHC | National Museum of African American History & Culture | Condensing Boilers | CB-2 | Fulton | VTG-4000LE | 3-Fair | 06/08/2016 | |
| 117952 | NMAAHC | National Museum of African American History & Culture | Condensing Boilers | CB-3 | Fulton | VTG-4000LE | 3-Fair | 06/08/2016 | |
| 117953 | NMAAHC | National Museum of African American History & Culture | Condensing Boilers | CB-4 | Fulton | VTG-4000LE | 3-Fair | 06/08/2016 | |
| 117954 | NMAAHC | National Museum of African American History & Culture | Condensing Boilers | CB-5 | Fulton | VTG-4000LE | 3-Fair | 06/08/2016 | |
| 117955 | NMAAHC | National Museum of African American History & Culture | Condensing Boilers | CB-6 | Fulton | VTG-4000LE | 3-Fair | 06/08/2016 | |
| 117947 | NMAAHC | National Museum of African American History & Culture | Boiler- Steam Natural Gas | SB-1 | Fulton | ICT-30-LE | 4-Good | 06/08/2016 | |
| 117948 | NMAAHC | National Museum of African American History & Culture | Boiler- Steam Natural Gas | SB-2 | Fulton | ICT-30-LE | 4-Good | 06/08/2016 | |
| 117949 | NMAAHC | National Museum of African American History & Culture | Boiler- Steam Natural Gas | SB-3 | Fulton | ICT-30-LE | 4-Good | 06/08/2016 | |
| 107670 | NMAH | National Museum of American History | Condensing Boilers | Boiler #1 | Benchmark | 3-Fair | 01/01/2011 | ||
| 107669 | NMAH | National Museum of American History | Condensing Boilers | Boiler #2 | Benchmark | 4-Good | 01/01/2008 | ||
| 107668 | NMAH | National Museum of American History | Condensing Boilers | Boiler #3 | Benchmark | 4-Good | 01/01/2011 |
SMZ
| *Anything in Red needs to be either added into Tririga or has is in Tririga, but would not pull up on the inventory due to its CSI code (ie a pump and not a boiler) | |||||||||
| Asset ID | Property | Building | Catalog Name | Local Name | Brand | Model Number | Serial Number | Condition | In Service Date |
| 1051927 | Freer\Freer | Freer Gallery of Art | Boiler- Steam Oil/Gas/Comb | Boiler #1 | CEMLINE Corporation | 4 - Good | 01/01/2016 | ||
| 1051928 | Freer\Freer | Freer Gallery of Art | Boiler- Steam Oil/Gas/Comb | Boiler #2 | CEMLINE Corporation | 4 - Good | 01/01/2016 | ||
| FM02509 | Freer\Freer | Freer Gallery of Art | Boiler-Steam Unfired | STGEN-1 | CEMLINE Corporation | V160USG1630 | 68861 | 4 - Good | 09/01/2016 |
| FM02510 | Freer\Freer | Freer Gallery of Art | Boiler-Steam Unfired | STGEN-2 | CEMLINE Corporation | V160USG1630 | 68862 | 4 - Good | 09/01/2016 |
| 111438 | Quad | Quadrangle | Boiler- Steam Oil/Gas/Comb | UNFIRED STEAM GENERATOR # 2 | CEMLINE Corporation | V240USG1636 | 60467 | 5 - Excellent | 03/23/1992 |
| 111440 | Quad | Quadrangle | Boiler- Steam Oil/Gas/Comb | UNFIRED STEAM GENERATOR # 1 | CEMLINE Corporation | V240USG1636 | 60467 | 5 - Excellent | 03/23/1992 |
NYZone
| *Anything in Red needs to be either added into Tririga or has is in Tririga, but would not pull up on the inventory due to its CSI code (ie a pump and not a boiler) | |||||||||
| Asset ID | Property | Building | Catalog Name | Local Name | Brand | Model Number | Serial Number | Condition | In Service Date |
| 134793 | CH-Main, NY | Cooper Hewitt, NY | Boiler- Steam Natural Gas | Boiler | Fulton | ICX20 | PV279KK | 4 - Good | 01/01/2014 |
| 134794 | CH-Main, NY | Cooper Hewitt, NY | Hot Water Boiler | Boiler #4 | RBI | CB1500 | 71262306 | 4 - Good | 01/01/2014 |
| 134795 | CH-Main, NY | Cooper Hewitt, NY | Hot Water Boiler | Boiler #3 | RBI | CB1500 | 71262316 | 4 - Good | 10/01/2020 |
| 134796 | CH-Main, NY | Cooper Hewitt, NY | Hot Water Boiler | Boiler #2 | RBI | CB1500 | 71262293 | 4 - Good | 10/01/2020 |
| 1347947 | CH-Main, NY | Cooper Hewitt, NY | Hot Water Boiler | Boiler #1 | RBI | CB1500 | 71262305 | 4 - Good | 01/01/2014 |
| CH-NY | Main Building | secondary heat exchanger | B1-B2-B3-B4 | 2-Poor | 10/30/2005 |
New Zone
| *Anything in Red needs to be either added into Tririga or has is in Tririga, but would not pull up on the inventory due to its CSI code (ie a pump and not a boiler) | |||||||||
| Asset ID | Property | Building | Catalog Name | Local Name | Brand | Model Number | Serial Number | Condition | In Service Date |
| 50531 | Anacostia | Anacostia Community Museum | Boiler- Steam Oil/Gas/Comb | boiler-1 | Peerless Electric | lc-07-wup | 307099-200003 | 5 - Excellent | 06/11/2008 |
| 50532 | Anacostia | Anacostia Community Museum | Boiler- Steam Oil/Gas/Comb | boiler-2 | Peerless Electric | lc-07-wup | 307098-200002 | 5 - Excellent | 06/11/2008 |
| 20022 | NMAI-DC | National Museum of the American Indian | Boiler- Steam Oil/Gas/Comb | B-3 | Cleaver Brooks | CBI200 200 125 | 0L101888 | 4 - Good | 01/01/2004 |
| 20023 | NMAI-DC | National Museum of the American Indian | Boiler- Steam Oil/Gas/Comb | B-1 | Cleaver Brooks | CBI200 200 125 | 0L101887 | 4 - Good | 01/01/2004 |
| 20024 | NMAI-DC | National Museum of the American Indian | Boiler- Steam Oil/Gas/Comb | B-2 | Cleaver Brooks | CBI200 200 125 | 0L101886 | 4 - Good | 01/01/2004 |
| FM03019 | NMAI-DC | National Museum of the American Indian | Boiler- Steam Oil/Gas/Comb | B-6 | Fulton | 1CS 60 | PV501MM | 4 - Good | 01/01/2014 |
| FM03020 | NMAI-DC | National Museum of the American Indian | Boiler- Steam Oil/Gas/Comb | B-5 | Fulton | 1CS 60 | PV500MM | 4 - Good | 01/01/2014 |
| FM03021 | NMAI-DC | National Museum of the American Indian | Boiler- Steam Oil/Gas/Comb | B-4 | Fulton | 1CS 60 | PV499MM | 4 - Good | 01/01/2014 |
UNWZ
| *Anything in Red needs to be either added into Tririga or is in Tririga, but would not pull up on the inventory due to its CSI code (ie a pump and not a boiler). Anything highlighted in yellow has NOT yet been field verified by planners. | |||||||||
| Asset ID | Property | Building | Catalog Name | Local Name | Brand | Model Number | Serial Number | Condition | In Service Date |
| 5409 | NZP-DC | Necropsy | Boiler- Electric | Not avilable | Ruud | ME52-2 | 0192B03850 | 5 - Excellent | |
| 5421 | NZP-DC | Necropsy | Heating Boilers | NE-M1-BLG-01 | Weil-McLain | CGA5 - PIDN | Not Available | 3 - Fair | 02/22/2007 |
| 5474 | NZP-DC | Conservation Biology | Boiler- Steam Natural Gas | RE-M1-BLG-01 | Weil-McLain | 988 | Not Available | 4 - Good | 02/22/2007 |
| 5475 | NZP-DC | Conservation Biology | Boiler- Steam Natural Gas | RE-M1-BLG-02 | Weil-McLain | 988 | Not Available | 4 - Good | 02/22/2007 |
| 5476 | NZP-DC | Conservation Biology | Boiler- Steam Oil/Gas/Comb | RE-M1-BLG-03 | Hurst | 988 | FB300 15-3M | 4 - Good | 02/22/2007 |
| 5593 | NZP-DC | Quarantine | Boiler- Steam Natural Gas | QB-M1-BLG-01 | Burnham | 209NSL-BEI2q | 64554394 | 5 - Excellent | 02/22/2007 |
| 102122 | NZP-DC | Asian Small Clawed Otters | Boiler- Steam Natural Gas | B1 | Hydrotherm | AM-100 | 06470342 | 5 - Excellent | |
| 102123 | NZP-DC | Asian Small Clawed Otters | Boiler- Steam Natural Gas | B2 | Hydrotherm | AM-100 | 0647017E | 5 - Excellent | |
| 102234 | NZP-DC | Elephant Outpost Restrooms | Condensing Boilers | Hot Water Boiler | Lochinvar | KBN600 | F09H10108069 | 4 - Good | 01/01/2015 |
| 102261 | NZP-DC | Sloth Bear | Boiler- Steam Oil/Gas/Comb | B-SI | Hydrotherm | AM-100 | 345334E | 4 - Good | |
| 102262 | NZP-DC | Sloth Bear | Boiler- Steam Natural Gas | B-S2 | Hydrotherm | AM-100 | 0243942E | 4 - Good | |
| 102365 | NZP-DC | Cheetah Conservation Station (Building) | Boiler- Steam Natural Gas | B-1 | Weil-McLain | CGI-4-P1N | N/A | 5 - Excellent | |
| 102366 | NZP-DC | Cheetah Conservation Station (Building) | Boiler- Steam Natural Gas | B-2 | Weil-McLain | CGI-4-PIN | N/A | 5 - Excellent | |
| 102367 | NZP-DC | Cheetah Conservation Station (Building) | Boiler- Steam Natural Gas | B-3 | Weil-McLain | CGI-4-PIN | N/A | 5 - Excellent | |
| 102664 | NZP-DC | Seals & Sea Lions | Boiler- Steam Natural Gas | Boiler | Not Available | KN-10+ | 42181312 | 5 - Excellent | 08/03/2021 |
| 111104 | NZP-DC | Panda House | Condensing Boilers | Panda House Boiler #1 | RBI | IB399 | 14300201 | 4 - Good | 01/01/2014 |
| 111105 | NZP-DC | Panda House | Condensing Boilers | Panda House Boiler #2 | RBI | 1B399 | 14300201 | 3 - Fair | 01/01/2014 |
| 111106 | NZP-DC | Panda House | Condensing Boilers | Panda House Boiler #3 | RBI | 1B399 | 14300202 | 3 - Fair | 01/01/2014 |
| 1001566 | NZP-DC | Bird House | Condensing Boilers | B-01 | Fulton | EDR+2500 | 0961-FHS | 4 - Good | 04/01/2020 |
| 1001567 | NZP-DC | Bird House | Condensing Boilers | B-02 | Fulton | EDR+2500 | 0958-FHS | 4 - Good | 04/01/2020 |
| 1001568 | NZP-DC | Bird House | Condensing Boilers | B-03 | Fulton | EDR+2500 | 0962-FHS | 4 - Good | 04/01/2020 |
| 1051933 | NZP-DC | Sloth Bear | Boiler- Steam Oil/Gas/Comb | B-S3 | VCX-242-GHS | 76913-01-01 | 2 - Poor | 01/01/2005 | |
| 1051934 | NZP-DC | Sloth Bear | Boiler- Steam Natural Gas | B-S4 | Liebert | DDNL310A | 0503C75071 | 2 - Poor | 01/01/2005 |
| 1051935 | NZP-DC | Visitors Center | Boiler- Steam Natural Gas | Boiler #1 | Weil-McLain | Power Flame Burner S#090205388 | 4 - Good | 01/01/2003 | |
| 1051936 | NZP-DC | Visitors Center | Boiler- Steam Natural Gas | Boiler #2 | York | YCWZ88LMO/17PB | 4 - Good | 01/01/1996 | |
| 1051941 | NZP-DC | Think Tank | Boiler- Steam Oil/Gas/Comb | Boiler | 2464701A94B | 5 - Excellent | 01/01/2005 | ||
| FM04021 | NZP-DC | Visitors Center | Heating Boilers | Heating Boiler | Smith Cast Iron Boilers | 19HE-8 | 210119 | 4 - Good | 01/01/2019 |
| FM08721 | NZP-DC | Sloth Bear | Condensing Boilers | BOILER 1 | NTI BOILERS | TFT110 | 92382 | 4 - Good | 01/01/2011 |
| FM08722 | NZP-DC | Sloth Bear | Condensing Boilers | BOILER 2 | NTI BOILERS | TFT110 | 112006 | 4 - Good | 01/01/2011 |
| FM10709 | NZP-DC | Asian Small Clawed Otters | Condensing Boilers | BOILER 1 (ASIAN SMALL CLAWED OTTERS) | RBI | IB199 | 15310051 | 4 - Good | 01/01/2015 |
| FM10710 | NZP-DC | Asian Small Clawed Otters | Condensing Boilers | BOILER 2 (ASIAN SMALL CLAWED OTTERS) | RBI | IB199 | 15310050 | 4 - Good | 01/01/2015 |
| FM10831 | NZP-DC | Seals & Sea Lions | Condensing Boilers | Hot water Boiler NG | Advanced Thermal Hydronics ATH | KN10+ | 4218132 | 4 - Good | 01/01/2022 |
| FM10966 | NZP-DC | Quarantine | Heating Boilers | NA | U.S. Boiler Co. | 209E | 65715822 | 4 - Good | 08/01/2019 |
| FM11075 | NZP-DC | Cheetah Conservation Station (Building) | Heating Boilers | BOILER#1 | Weil-McLain | CGI-4PIN | 3 | 4 - Good | 01/01/2010 |
| FM11076 | NZP-DC | Cheetah Conservation Station (Cheetah) | Heating Boilers | BOILER # 2 | Weil-McLain | CGI-4PIN | N/A | 10/04/2015 | |
| FM11077 | NZP-DC | Cheetah Conservation Station (Cheetah) | Heating Boilers | BOILER # 3 | Weil-McLain | CGI-4PIN | N/A | 10/04/2015 | |
| ? | NZP-DC | Research Building | Boiler- Steam Natural Gas | Research Building #1 | Weil-McLain 88 Series | 3 - Fair | 1/1/01 | ||
| ? | NZP-DC | Research Building | Boiler- Steam Natural Gas | Research Building #2 | Weil-McLain 88 Series | 3 - Fair | 1/1/01 | ||
| 102365 | NZP-DC | Cheetah Conservation Station | Heating Boilers | B-1 | Weil-McLain | 4 - Good | 02/22/2007 | ||
| 102367 | NZP-DC | Cheetah Conservation Station | Heating Boilers | B-3 | Weil-McLain | 3 - Fair | 02/22/2007 | ||
| 102664 | NZP-DC | Seals & Sea Lions | Heating Boilers | Boiler | 2-Poor | 12/19/2011 | |||
| 117539 | NZP-VA | Stone House | Heating Boilers | Heating Boiler | Lochinvar Corporation | KBN150 | C10H10133188 | 3 - Fair | 10/04/2015 |
| FM00187 | NZP-VA | MFH House 2518 Remount Road | Heating Boilers | HEATING BOILER (MFH 2518 REMOUNT ROAD) | Lochinvar | KBN150 | D10H10133269 | 4 - Good | 04/01/2010 |
| FM00257 | NZP-VA | Boiler Room/Mason Shop | Heating Boilers | MASON SHOP 407 GAS BOILER | Lochinvar | KBN399 | LO8H10089832M-9 | 4 - Good | 02/21/1993 |
| FM00258 | NZP-VA | Field Ecology Office | Cast-Iron Boilers | ECOLOGY 25 BOILER B-100 | Weil-McLain | P-WGO-4 | 3 | 4 - Good | 06/20/2008 |
| FM011246 | NZP-VA | Dormitory (Research Drive) | Heating Boilers | Boiler | Lochinvar Corporation | KBN211 | L13H10283768 | 4 - Good | 09/04/2014 |
| FM01418 | NZP-VA | Cryo/Bio Labs | Condensing Boilers | Cryo-Lab Boiler #1 | Fulton | EDR-1000 | 5835-HFTC | 4 - Good | |
| FM01419 | NZP-VA | Cryo/Bio Labs | Condensing Boilers | Cryo-Lab Boiler #2 | Fulton | EDR-1000 | 5826-HFTC | 4 - Good | |
| FM11304 | NZP-VA | MFH House 86 Administration Drive | Heating Boilers | GAS FIRED HOT WATER BOILER | Lochinvar Corporation | KBN501 | D15H10343402 | 3 - Fair | 10/04/2015 |
| FM11910 | NZP-VA | Animal Programs & Neon Office | Heating Boilers | BOILER 1 | Lochinvar | FBL1001 | 2250 131950437 | 5 - Excellent | 05/31/2023 |
| FM11911 | NZP-VA | Animal Programs & Neon Office | Heating Boilers | BOILER 2 | Lochinvar | FBL1001 | 2250 131950438 | 5 - Excellent | 05/31/2023 |
File details come from the government source that posted it. Updated .