Copy of Smithsonian Equipment Revision 2018 Boilers.xlsx
XLSX spreadsheet 47 KB Posted
- Attached to
- 33330225RF0010015 - Indefinite Delivery/Indefinite Quantity SI Wide Boiler Services Contract
- Solicitation number
- 33330225RF0010015
- Issued by
-
Smithsonian Institution
About this file
The file is an Excel spreadsheet detailing equipment inventory for boilers and chillers across multiple Smithsonian Institution facilities in Washington DC, New York City, Maryland, and Virginia. The comprehensive inventory lists over 100 pieces of HVAC equipment, including boilers and chillers from manufacturers such as Cleaver Brooks, York, Trane, and Fulton, with details on their age, serial numbers, and recommended maintenance or replacement status.
The equipment spans various Smithsonian locations including the National Zoo, American History Museum, National Museum of African American History & Culture, Cooper Hewitt, and other facilities. Many units are approaching or have exceeded their recommended life cycle, with recommendations ranging from continued use, replacement in specific years (2018-2023), to immediate replacement due to age or obsolete components. The inventory corresponds to Solicitation Number 33330225RF0010015, an Indefinite Delivery/Indefinite Quantity (IDIQ) contract for preventive and remedial maintenance services for boilers, targeting NAICS codes 238220 and 221330, with a 12-month base period and nine optional renewal periods.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Boilers Location and Equipment Information List 1 Final.pdf | ||
| 33330225RF0010015 Amend 0004.pdf | ||
| 33330225RF0010015 Amend 0003.pdf | ||
| 33330225RF0010015 POOOO2.pdf | ||
| 33330225RF0010015 Amendment 0001.pdf | ||
| ATTACHMENT H SI-707.pdf | ||
| ATTACHMENT D OCon_520.doc | DOC document | |
| 33330225RF0010015 Final.pdf | ||
| ATTACHMENT G SD419.pdf | ||
| ATTACHMENT B Final Inventory.xlsx | XLSX spreadsheet | |
| ATTACHMENT C Tririga Usage Section 5.30.24.docx | DOCX document | |
| ATTACHMENT F Confined space permit.xlsx | XLSX spreadsheet | |
| ATTACHMENT E Hot Work Permit (Daily) NEW.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BOTH
Replace after Unit reach Life Cycle Any thing not on this will only be cover for repairs no PM schedule has been enter for contract. The SI force will be responsible for all Preventive Maintenance.. (NOPM) NOT on Contractor PM Plan Critical
| National Zoo | Not on PM(NOPM) | |||||
| Location | Manufacture | Model | Serial | Age | Recommendations | Critiical |
| Main Boiler Plant | Cleaver Brooks | CB I1700-500 | L-93856 | 23 | Recently had new boiler controls installed | 150 Tubes Replacement 2018 |
| Main Boiler Plant | Cleaver Brooks | CB I1700-500 | L-93857 | 23 | Recently had new boiler controls installed | |
| Main Boiler Plant | Cleaver Brooks | CB I1700-500 | 23 | Recently had new boiler controls installed | ||
| DA Tank | Cleaver Brooks | 23 | Total replacement 2018 | Inprogress | ||
| Sloth Bear | HydroTherm | AM-100 | 0345334E | 15 | Near the end of the boilers useful life of 15 years | |
| Sloth Bear | HydroTherm | AM-100 | 0243942E | 16 | Near the end of the boilers useful life of 15 years | |
| Sloth Bear | Mammoth | VCX-242-GHS | 76913-01-01 | 13 | Near the end of the boilers useful life of 15 years | 2020 |
| Sloth Bear | Liebert Dry cooler | DDNL310A | 0503C75071 | 13 | Near the end of the boilers useful life of 15 years | 2020 |
| Visitor Center | Weil Mclain Series 80 | Power Flame Burner S#090205388 | 16 | Cast iron Sectional/ Life cycle 30years | ||
| Visitor Center | York | YCWZ88LMO/17PB | YAAM837711 | 25 | Eddy Current | |
| Visitor Center | BAC | VXT105CM | 92-100147 | 26 | Replace tower due to age | |
| Asian Small Clawed Otter | HydroTherm | AM-100 | 0647034E | 12 | 15 year life cycle/ my obsolete | |
| Asian Small Clawed Otter | HydroTherm | AM-100 | 0647017E | 12 | 15 year life cycle/ my obsolete | |
| Otter Pool Heater | Lochinvar | ERN401 | E06H00006287 | 12 | 15 year life cycle/ my obsolete | |
| Cat Holding House | Trane | DFIA1091FGNB4AAD35000ACADAV | F06A01154 | 12 | 15 year life cycle/ my obsolete | |
| Panda House | RBI | IB399 | 14300202 | 4 | Replaced in 2014 | SED Completed |
| Panda House | RBI | IB399 | 14300203 | 4 | Replaced in 2014 | SED Completed |
| Panda House | RBI | IB399 | 14300201 | 4 | Replaced in 2014 | SED Completed |
| Panda House | McQuay | AGZ085BS27-ER11 | STNU040200144 | 14 | 20 year life cycle | |
| Reptile House | Trane | RTHB150FMF00LW00MOUNN3LF2LFV00U0 | U97F02372 | 21 | Eddy Current | |
| Reptile House | Trane | RTHB150FMF00LW00MOUNN3LF2LFV00U0 | U97E02368 | 21 | Eddy Current | |
| Reptile House | Evapco | AT 8-812B | 971362 | 21 | Should consider replacement due to age | |
| Think Tank | Dunham-Bush | ACDR055A | 2464701A94B | 14 | Should consider replacement due to age | |
| Lion House | York | YCWZ77JMO/46PB | YLAM837755 | Approx. 23 | Eddy Current | |
| Amazonia | Trane | 4 | NEW Replaced in 2016 | |||
| Police | Westinghouse Condenser | 3808016---5 | 2092F99964 | 26 | Should consider replacement due to age | |
| Police | Westinghouse AHU | AB100BIX | 353AI77G02 | 26 | Should consider replacement due to age | |
| Police | Carrier Condenser | 38AE-016---500- - | 2092F99964 | 26 | Should consider replacement due to age | |
| Police | Carrier AHU | 40RR-016---540- - | 2492F04619 | 26 | Should consider replacement due to age | |
| Main Restaurant | Carrier | 30GXR083-A-640FZ | 0303F12153 | 15 | 20 year life cycle | |
| Bird House | Weil Mclain 88 Series | Webster Burner S#U69160A-01-02-03 | 18 | 30 year life cycle | ||
| Bird House | Trane | RTAA155G"YJ01R101BFG | E95U95J29818 | 23 | 20 year life cycle/should consider replacement | Exhibit being closed for renovations this summer |
| Research Building | BAC Tower | VFL103-F2 | U002061502 | 16 | 20 year life cycle | |
| Research Building | BAC Tower | VTL103-KR | U002061501 | 16 | 20 year life cycle | |
| Research Building | Weil-McLain 88 Series | Gordon Piatt M#WR8.4-G-20 | 17 | Replace obsolete burners | ||
| Research Building | Weil-McLain 88 Series | Gordon Piatt M#WR8.4-G-20 | 17 | Replace obsolete burners | ||
| Research Building | Hurst | S1-G-60-15 | FB300-15-3M | 16 | Replace obsolete burners | |
| Research Building | Trane | RTWA100AYE01C3DOWFN | U00K04474 | 18 | Eddy Current | |
| Research Building | Trane | RTWA100AYE01C3DOWFN | U00K04472 | 18 | Eddy Current | |
| Vet. Hospital | RBI Futera II | FWN750E-00 | 90021784 | 16 | 15 year life cycle | |
| Vet. Hospital | Trane | RTAC1404URONUAPNN1WX1TDNBA0EN11NR0EXN | U09B02991 | 9 | 20 year life cycle | |
| Quarantine | Burnham | 209NSL-BE12 | 64554394 | 15 | 30 year life cycle | |
| Sea Lion | Viessmann | CT3-28 | 7.1423580001831E+15 | 8 | 15 year life cycle | |
| Sea Lion | Trane | RTAC 1554 UFON UAFN L4NY 1TDN NNOE A11B ROEX N | U03J00B33 | 15 | 20 year life cycle | |
| Sea Lion | Trane | RTAC 1554 UFON UAFN L4NY 1TDN NNOE A11B ROEX N | U03H00832 | 15 | 20 year life cycle | |
| Sea Lion | York | YCAL002BEE46XEASDTXAXXRLXXXX45XX1XXXXXXVSXXXBXX1XXXXXNH5AXXX | SEXM-936420 | 25 | 20 year life cycle/ consider for replacement | |
| General Services Building | Evapco | AT8-312B | 961176 | 22 | 20 year life cycle/ consider for replacement | 20 |
| General Services Building | Trane | RTHB215FMD00LW0000UNN3LF2LFV00U0 | U96E04310 | 22 | Eddy Current |
| DWRC | ||||||
| Manufacture | Model | Serial | Age | Recommendations | ||
| AO Smith | HWG 250V D0A008005 | SM04106579 Y3 | 14 | 15 year life cycle | ||
| Boiler #1 | RBI | FB1000NOR2A3CA | 080436117 | 2 | Recently replaced 2016 | SED Completed |
| Boiler #2 | RBI | FB1000NOR2A3CA | 080436088 | 2 | Recently replaced 2016 | SED Completed |
| Boiler #3 | RBI | FB1000NOR2A3CA | 080436118 | 2 | Recently replaced 2016 | SED Completed |
| Boiler #4 | RBI | FB1000NOR2A3CA | 080436106 | 2 | Recently replaced 2016 | SED Completed |
| Boiler #5 | RBI | FB1000NOR2A3CA | 080436116 | 1 | Recently replaced 2017 | SED Completed |
| Boiler #6 | RBI | FB1000NOR2A3CA | 080436094 | 1 | Recently replaced 2017 | SED Completed |
| Boiler #7 | RBI | FB1000NOR2A3CA | 080436086 | 1 | Recently replaced 2017 | SED Completed |
| Boiler #8 | RBI | FB1000NOR2A3CA | 080436107 | 1 | Recently replaced 2017 | SED Completed |
| Chiller | York | YKHHGDJ1-CAF | SBNM-233350 | 14 | Eddy Current | |
| Chiller | York | YKHHGDJ1-CAF | SBNM-233220 | 14 | Eddy Current | |
| Renwick Gallery | ||||||
| Manufacture | Model | Serial | Age | Recommendations | ||
| Boiler #1 | Patterson Kelly | SWM2000 | CN13-04-26225 | 14 | 15 year life cycle | 2020 |
| Boiler #2 | Patterson Kelly | SWM2000 | CN13-04-26226 | 14 | 15 year life cycle | 2020 |
| Chiller Module 1 | MultiStack | MS50XGA2W1 | AA03255 | 15 | 15 year life cycle | |
| Chiller Module 2 | MultiStack | MS50XGA2W1 | AA03256 | 15 | 15 year life cycle | |
| Chiller Module 3 | MultiStack | MS50XGA2W1 | AA03257 | 15 | 15 year life cycle | |
| Chiller Module 4 | MultiStack | 4 | 15 year like cycle 2016 | |||
| Natural History | ||||||
| Manufacture | Model | Serial | Age | Recommendations | ||
| Chiller #1 | Trane | CVHE112NA1M03GX257911E9X1C00000003A00000 | L92E13100 | 26 | 30 year life cycle/ controls are obsolate and need to be replaced | SED motor replacement |
| Chiller #2 | Trane | CVHE112NA1M03GX257911E9X1C00000003A00000 | L92E13101 | 26 | 30 year life cycle/ controls are obsolate and need to be replaced | 2022 |
| Chiller #3 | Trane | CVHE112NA1M03GX257911E9X1C00000003A00000 | L92E12998 | 26 | 30 year life cycle/ controls are obsolate and need to be replaced | 2022 |
| Chiller #4 | Trane | CVHE125NB1M03GX253931E9X1C9X1C0003A00000 | L92E12997 | 26 | 30 year life cycle Control where recently replaced/OK | 2014 Overhaul |
| Chiller #5 | Trane | CVHF108NE4A0FCZ289BEFECC1CC1C0000000Z01G000LS00004A100B | L10J04981 | 8 | 30 year life cycle | |
| American History | ||||||
| Manufacture | Model | Serial | Age | Recommendations | ||
| Chiller #1 | York | YKVHTDJ3-DCFS | SNSM-761250 | 11 | Eddy Current | |
| Chiller #2 | York | YKKKKMH9-CUFS | SMSM-761600 | 11 | Eddy Current | |
| Chiller #3 | York | YKVHTDJ3-DCFS | SATM-810630 | 10 | Eddy Current | |
| Chiller #4 | York | YKKKKMH9-CUFS | SMSM-761480 | 11 | Motor was replace 2017 | |
| Boiler #1 | Benchmark | 3.0 Low Nox | G-08-0201 G-11-1530 | 7 | 15 to 20 life cycle/OK | |
| Boiler #2 | Benchmark | 3.0 Low Nox | G-08-0199 G-08-3093 | 10 | 15 to 20 life cycle/OK | 2023 |
| Boiler #3 | Benchmark | 3.0 Low Nox | G-08-01200 G-11-0938 | 7 | 15 to 20 life cycle/OK | |
| Anacostia Community Museum | ||||||
| Manufacture | Model | Serial | Age | Recommendations | ||
| Chiller | McQuay | AGR100AS12-ER10 | STNU000400032 | 18 | 20 year life cycle/should consider replacement | 135,000.00 Total Replacement needed 2014 |
| Boiler #1 | Peerless | LC-07-WUP | 307099-200003 | 18 | 30 year life cycle | |
| Boiler #2 | Peerless | LC-07-WUP | 307098-200003 | 18 | 30 year life cycle | |
| Hazy | ||||||
| Manufacture | Model | Serial | Age | Recommendations | ||
| Chiller #1 | Trane | RTHC1D2F0H0G3L4G3MF0QUCD | U02C03685 | 16 | Eddy Current | |
| Chiller #2 | Trane | RTHC1D2F0H0G3L4G3MF0QUCD | U02C03686 | 16 | Eddy Current | |
| Chiller #3 | Trane | CVHF091FA1W0ACV308CA8ECC9A0000000WA1004C0000003A1 | L02C05225 | 16 | Overhaul 2017 | |
| Chiller #4 | Trane | CVHF091FA1W0ACV308CA8ECC9A0000000WA1004C0000003A1 | L02C05227 | 16 | Overhaul 2017 | |
| Boiler #1 | Superior | 4-5 2007 | 14945 | 16 | 30 life cycle/OK | |
| Boiler #2 | Superior | 4-5 2007 | 14944 | 16 | 30 life cycle/OK | |
| Boiler #3 | Superior | 4-5 1024 | 14940 | 16 | 30 life cycle/OK | |
| American Indian Museum - DC | ||||||
| Manufacture | Model | Serial | Age | Recommendations | ||
| Boiler #1 | Cleaver Brooks | CB/200 200 125 | OL101887 | 16 | 30 year life cycle | |
| Boiler #2 | Cleaver Brooks | CB/200 200 125 | OL101886 | 16 | 30 year life cycle | |
| Boiler #3 | Cleaver Brooks | CB/200 200 125 | OL101888 | 16 | 30 year life cycle | |
| Boiler #4 | Fulton | ICS60 | 91863 | 4 | Relatively new | SED |
| Boiler #5 | Fulton | ICS60 | 91866 | 4 | Relatively new | SED |
| Boiler #6 | Fulton | ICS60 | 91873 | 4 | Relatively new | SED |
| Quadrangle | ||||||
| Manufacture | Model | Serial | Age | Recommendations | ||
| Boiler #1 | Cemline | V240USG1636 | 60467 | 10 | 20 life cycle/OK | 2028 |
| Boiler #2 | Cemline | V240USG1636 | 40460 | 10 | 20 life cycle/OK | 2028 |
| Heat Exchanger 1 | Totally Clean 2018 | NOPM | ||||
| Heat Exchanger 2 | Totally Clean 2018 | NOPM | ||||
| Heat Exchanger 3 | Totally Clean 2018 | NOPM | ||||
| Freer | ||||||
| Manufacture | Model | Serial | Age | Recommendations | ||
| Boiler#1 | Cemliune | 2 | OPDC | |||
| Boiler#2 | Cemliune | 2 | OPDC | |||
| SERC | ||||||
| Manufacture | Model | Serial | Age | Recommendations | ||
| Main Building | ||||||
| Electric Boiler | Bryan | 165BHW4T6, KW165 | 99111 | 7 | ||
| FHP #1 | FHP | WW420-4C5C | 3540-208-00001-T11M51559 | 7 | ||
| FHP #2 | FHP | WW420-4C5C | 3540-208-00003-T111M51559 | 7 | ||
| FHP #3 | FHP | WW420-4C5C | 3540-208-00004-T111M51559 | 7 | ||
| FHP #4 | FHP | WW420-4C5C | 3540-208-00005-T111M51559 | 7 | ||
| FHP #5 | FHP | WW420-4C5C | 3540-208-00006-T111M51559 | 7 | ||
| FHP #6 | FHP | WW420-4C5C | 3540-208-00008-T111M51559 | 7 | ||
| FHP #7 | FHP | WW420-4C5C | 3540-208-00002-T111M51559 | 7 | ||
| FHP #8 | FHP | WW420-4C5C | 3540-208-00009-T111M51559 | 7 | ||
| FHP #9 | FHP | WW420-4C5C | 3540-208-000011-T111M51559 | 7 | ||
| FHP #10 | FHP | WW420-4C5C | 3540-208-00007-T111M51559 | 7 | ||
| FHP #11 | FHP | WW420-4C5C | 3540-208-000010-T111M51559 | 7 | ||
| FHP #12 | FHP | WW420-4C5C | 3540-208-000012-T111M51559 | 7 | ||
| Admin Building | ||||||
| Boiler (oil fired) | Burnham | V0A/V11 | V9003-1-04 | |||
| Maintenance Shop | ||||||
| Boiler (oil fired) | Burnham | V0A/V11 | 225.60.3 | |||
| Manor House | ||||||
| Boiler (oil fired) | Columbia | CSFH4150WLC | UDC19832 | 12 | ||
| Schmidt Building | ||||||
| Furnace | Trane | 4TXCD061BC3HCAA | N/A | 9 | ||
| Furnace | Trane | 4TXCD061BC3HCAA | 9415JRM5G | 9 | ||
| Furnace | Trane | 4TXCC037BC3HCAA | 9382ULF5G | 9 | ||
| Furnace | Trane | 4TXCD061BC3HCAA | 9415JMT5G | 9 | ||
| Condenser | Trane | 4TTB3036B1000BA | 9421LU43F | 9 | ||
| Condenser | Trane | 4TTB3060A1000BA | 9384W2D5F | 9 | ||
| Condenser | Trane | 4TTB3060A1000BA | 9402JC22F | 9 | ||
| Condenser | Trane | 4TTB3060A1000BA | 9384WU95F | 9 | ||
| MSC | ||||||
| Main Plant | Manufacture | Model | Serial | Age | Recommendations | |
| Boiler #1 | Cleaver Brooks | CB200-250 | L-71336 | 2 | 2017 Replacement | |
| Boiler #2 | Cleaver Brooks | CB200-250 | L-71335 | 2 | 2017 Replacement | |
| Boiler #3 | Cleaver Brooks | CB200-250 | L-71337 | 2 | 2017 Replacement | |
| Chiller | Trane | RTWD 080F 2O02 A1C1 AA2A 1A1Y 1B1A 400A 0010 000A 70A1 00D0 | U15C01502 | 3 | Eddy Current | |
| Chiller | York | YKEREPQ4-CLG | SFTM-001460 | 10 | Eddy Current | |
| Chiller | York | YKCQCSQ4-CJG | SBWM-509970 | 8 | Eddy Current | |
| Chiller | York | YKEREPQ4-CLG | SEWM601480 | 8 | Eddy Current | |
| POD-3 | York | |||||
| Chiller | York | YLAA0135SE46XAABXTCATXBLXCXX44SX1XXXHXXXSAXXXXX7XXXXXNDXAXXX | SHVM354010 | 9 | ||
| POD-5 | York | |||||
| Boiler #1 | Fulton | VMP 130 | 101589 | 12 | 15 year to 20 life cycle/OK | 2021 |
| Boiler #2 | Fulton | VMP 130 | 101578 | 12 | 15 year to 20 life cycle/OK | 2021 |
| Chiller #1 | York | YCAV0227SA46VAABXTXXBXXLXXXX42SXXXXXHXXWSAXXXXX3XXXXXNBXAXXX | SFRM-263730 | 12 | ||
| Chiller #2 | York | YCAV0227SA46VAABXTXXBXXLXXXX42SXXXXXHXXWSAXXXXX3XXXXXNBXAXXX | SFRM-263680 | 12 | ||
| Chiller #3 | York | YCAV0187SA46VAABXTXXBXXLXXXX42SXXXXXHXXWSAXXXXX3XXXXXNBAXXX | SGRM-264410 | 12 | ||
| Storage 17 | ||||||
| Boiler #1 | Weil McLain | CGA-7-PIDM | CP3942557 | 18 | 30 life cycle/OK | |
| Boiler #2 | Weil McLain | CGA-7-PIDM | CP3942566 | 18 | 30 life cycle/OK | |
| Greenhouse | 3 | |||||
| Boiler #1 | Raypak | H7-1253 | 910301783 | 9 | 15 year life cycle | |
| CRC | ||||||
| Manufacture | Model | Serial | Age | Recommendations | ||
| Bldg 10 | Chiller | Not on PM Schedule | 109,000.00 Total Replacement Needed 2018 | |||
| Chiller | McQuay | PEH063-CCBC | 57G81075-00 | 19 | 10 Overhaul 2017 | warranty |
| Chiller | McQuay | PEH063-CCBC | 57G81071-00 | 19 | 10 Overhaul 2017 | warranty |
| Boiler #1 | Donlee | SPLV-100 N/2 | 9720283 | 19 | Replace Burner | |
| Boiler #2 | Donlee | SPLV-100 N/2 | 9720282 | 19 | Replace Burner | |
| Boiler #3 | Peerless | LC10-SUP | 354272-200104 | 15 | Nonfunctioning | |
| National Museum of African American History & Culture | ||||||
| Manufacture | Model | Serial | Age | Recommendations | ||
| Chiller | York | YKFDFTQ7-EPG | SCBM-918410 | 3-4 | ||
| Chiller | York | YKFDFTQ7-EPG | SCBM-918570 | 3-4 | ||
| Chiller | York | YKFDFTQ7-EPG | SCBM-918730 | 3-4 | ||
| Hot Water Boiler | Fulton | VTG-4000LE | 8515 | 3 | ||
| Hot Water Boiler | Fulton | VTG-4000LE | 8517 | 3 | ||
| Hot Water Boiler | Fulton | VTG-4000LE | 8518 | 3 | ||
| Hot Water Boiler | Fulton | VTG-4000LE | 8520 | 3 | ||
| Hydronic Boiler (condensing) | Fulton | CAL-500 | 2013-1007 | 4 | ||
| Hydronic Boiler (condensing) | Fulton | CAL-500 | 2013-1028 | 4 | ||
| Steam Boiler | Fulton | ICT-30-LE | 116718 | 3 | ||
| Steam Boiler | Fulton | ICT-30-LE | 116719 | 3 | ||
| Steam Boiler | Fulton | ICT-30-LE | 116722 | 3 | ||
| Water Heater | Aqua Plex | 1485L330A-TP | 0314137628 | 3 | ||
| Water Heater | Aqua Plex | 1485L330A-TP | 0314137629 | 3 | ||
| American Indian Museum - New York | ||||||
| Manufacture | Model | Serial | Age | Recommendations | ||
| Chiller | York | YS CA CA S1 CHA | SFBM92-803842 | 24 | Replace due to age & obsolete refrigerant | |
| Chiller | York | YS CA CA S1 CHA | SFMB928003581 | 24 | Replace due to age & obsolete refrigerant | |
| Cooling Tower | BAC | 3294-2S | 93400222 | 23 | Replace due to age(NOPM) | |
| Cooper Hewitt | ||||||
| Manufacture | Model | Serial | Age | Recommendations | ||
| Chiller #1 | Trane | RTHB150ALD00LW00M0UNN2LF2LFV00U | U95M01650 | 21 | Replace due to age & obsolete refrigerant | |
| Chiller #2 | Trane | RTHB150ALD00LW00M0UNN2LF2LFV00U | U95M01660 | 21 | Replace due to age & obsolete refrigerant | |
| Module #1 | ArticChill | PWCCMV0250D3-MM | A001028112 | 6 | Relatively new and in shape | heat exchanger need week cleaning |
| Module #2 | ArticChill | PWCCMV0250D3-MM | AA002028212 | 6 | relatively new and in shape | heat exchanger need week cleaning |
| Module #3 | ArticChill | PWCCMV0250D3-MM | A002028312 | 6 | relatively new and in shape | heat exchanger need week cleaning |
| Module #4 | ArticChill | PWCCMV0250D3-MM | A002028412 | 6 | relatively new and in shape | heat exchanger need week cleaning |
| Boiler #1 | RBI | CB1500 | 071262305 | 6 | Heat exchangers need replaced | |
| Boiler #2 | RBI | CB1500 | 071262293 | 6 | Heat exchangers need replaced | |
| Boiler #3 | RBI | CB1500 | 071262316 | 6 | Heat exchangers need replaced | |
| Boiler #4 | RBI | CB1500 | 071262306 | 6 | Heat exchangers need replaced | |
| Boiler | Fulton | 1CX-20 | PV279KK | 6 | relatively new and in shape |
Boiler National Zoo 3001 Connecticut Ave NW Washington DC 20008
| Location | Manufacture | Model | Serial | Age | Recommendations |
| Main Boiler Plant | Cleaver Brooks | CB I1700-500 | L-93856 | 21 | Recently had new boiler controls installed |
| Main Boiler Plant | Cleaver Brooks | CB I1700-500 | L-93857 | 21 | Recently had new boiler controls installed |
| Main Boiler Plant | Cleaver Brooks | CB I1700-500 | 21 | Recently had new boiler controls installed | |
| Sloth Bear | HydroTherm | AM-100 | 0345334E | 13 | Near the end of the boilers useful life of 15 years |
| Sloth Bear | HydroTherm | AM-100 | 0243942E | 14 | Near the end of the boilers useful life of 15 years |
| Sloth Bear | Mammoth | VCX-242-GHS | 76913-01-01 | 11 | Near the end of the boilers useful life of 15 years |
| Sloth Bear | Liebert Dry cooler | DDNL310A | 0503C75071 | 11 | Near the end of the boilers useful life of 15 years |
| Visitor Center | Weil Mclain Series 80 | Power Flame Burner S#090205388 | 14 | Cast iron Sectional/ Life cycle 30years | |
| Visitor Center | York | YCWZ88LMO/17PB | YAAM837711 | Approx. 23 | Eddy Current |
| Visitor Center | BAC | VXT105CM | 92-100147 | 24 | Replace tower due to age |
| Asian Small Clawed Otter | HydroTherm | AM-100 | 0647034E | 10 | 15 year life cycle/ my obsolete |
| Asian Small Clawed Otter | HydroTherm | AM-100 | 0647017E | 10 | 15 year life cycle/ my obsolete |
| Otter Pool Heater | Lochinvar | ERN401 | E06H00006287 | 10 | 15 year life cycle/ my obsolete |
| Cat Holding House | Trane | DFIA1091FGNB4AAD35000ACADAV | F06A01154 | 10 | 15 year life cycle/ my obsolete |
| Panda House | RBI | IB399 | 14300202 | 2 | 2014 |
| Panda House | RBI | IB399 | 14300203 | 2 | 2014 |
| Panda House | RBI | IB399 | 14300201 | 2 | 2014 |
| Reptile House | Evapco | AT 8-812B | 971362 | 19 | Should consider replacement due to age |
| Think Tank | Dunham-Bush | ACDR055A | 2464701A94B | 22 | Should consider replacement due to age |
| Bird House | Weil Mclain 88 Series | Webster Burner S#U69160A-01-02-03 | 16 | 30 year life cycle | |
| Research Building | Weil-McLain 88 Series | Gordon Piatt M#WR8.4-G-20 | 15 | Replace obsolete burners | |
| Research Building | Weil-McLain 88 Series | Gordon Piatt M#WR8.4-G-20 | 15 | Replace obsolete burners | |
| Research Building | Hurst | S1-G-60-15 | FB300-15-3M | 14 | Replace obsolete burners |
| Vet. Hospital | RBI Futera II | FWN750E-00 | 90021784 | 14 | 15 year life cycle |
| Quarantine | Burnham | 209NSL-BE12 | 64554394 | 13 | 30 year life cycle |
| Sea Lion | Viessmann | CT3-28 | 7.1423580001831E+15 | 6 | 15 year life cycle |
| DWRC | 1661 Pennsylvania Ave NW |
Washington DC 20006
| Manufacture | Model | Serial | Age | Recommendations | |
| AO Smith | HWG 250V D0A008005 | SM04106579 Y3 | 12 | 15 year life cycle | |
| Boiler #1 | RBI | FB1000NOR2A3CA | 080436087 | 12 | 15 year life cycle |
| Boiler #2 | RBI | FB1000NOR2A3CA | 080436108 | 12 | 15 year life cycle |
| Boiler #3 | RBI | FB1000NOR2A3CA | 080436104 | 12 | 15 year life cycle |
| Boiler #4 | RBI | FB1000NOR2A3CA | 080436117 | 12 | 15 year life cycle |
| Boiler #5 | RBI | FB1000NOR2A3CA | 080436088 | 12 | 15 year life cycle |
| Boiler #6 | RBI | FB1000NOR2A3CA | 080436118 | 12 | 15 year life cycle |
| Boiler #7 | RBI | FB1000NOR2A3CA | 080436106 | 12 | 15 year life cycle |
| Boiler #8 | RBI | FB1000NOR2A3CA | 080436116 | 12 | Recently replaced |
| Boiler #9 | RBI | FB1000NOR2A3CA | 080436094 | 1 | Recently replaced |
| Boiler #10 | RBI | FB1000NOR2A3CA | 080436086 | 1 | Recently replaced |
| Boiler #11 | RBI | FB1000NOR2A3CA | 080436107 | 1 | Recently replaced |
| Renwick Gallery | 1661 Pennsylvania Ave NW |
Washington DC 20006
| Manufacture | Model | Serial | Age | Recommendations | |
| Boiler #1 | Patterson Kelly | SWM2000 | CN13-04-26225 | 12 | 15 year life cycle |
| Boiler #2 | Patterson Kelly | SWM2000 | CN13-04-26226 | 12 | 15 year life cycle |
| American History | 1400 Constitution Ave NW |
Washington DC 20013
| Boiler #1 | Benchmark | 3.0 Low Nox | G-08-0201 G-11-1530 | 5 | 15 to 20 life cycle/OK |
| Boiler #2 | Benchmark | 3.0 Low Nox | G-08-0199 G-08-3093 | 8 | 15 to 20 life cycle/OK |
| Boiler #3 | Benchmark | 3.0 Low Nox | G-08-01200 G-11-0938 | 5 | 15 to 20 life cycle/OK |
| Anacostia Community Museum | |||||
| Boiler #1 | Peerless | LC-07-WUP | 307099-200003 | 16 | 30 year life cycle |
| Boiler #2 | Peerless | LC-07-WUP | 307098-200003 | 16 | 30 year life cycle |
| Hazy | |||||
| Manufacture | Model | Serial | Age | Recommendations | |
| Boiler #1 | Superior | 4-5 2007 | 14945 | 14 | 30 life cycle/OK |
| Boiler #2 | Superior | 4-5 2007 | 14944 | 14 | 30 life cycle/OK |
| Boiler #3 | Superior | 4-5 1024 | 14940 | 14 | 30 life cycle/OK |
| American Indian Museum - DC | |||||
| Manufacture | Model | Serial | Age | Recommendations | |
| Boiler #1 | Cleaver Brooks | CB/200 200 125 | OL101887 | 14 | 30 year life cycle |
| Boiler #2 | Cleaver Brooks | CB/200 200 125 | OL101886 | 14 | 30 year life cycle |
| Boiler #3 | Cleaver Brooks | CB/200 200 125 | OL101888 | 14 | 30 year life cycle |
| Boiler #4 | Fulton | ICS60 | 91863 | 2 | Relatively new |
| Boiler #5 | Fulton | ICS60 | 91866 | 2 | Relatively new |
| Boiler #6 | Fulton | ICS60 | 91873 | 2 | Relatively new |
| Quadrangle | |||||
| Manufacture | Model | Serial | Age | Recommendations | |
| Boiler #1 | Cemline | V240USG1636 | 60467 | 8 | 20 life cycle/OK |
| Boiler #2 | Cemline | V240USG1636 | 40460 | 8 | 20 life cycle/OK |
| Freer | |||||
| Manufacture | Model | ||||
| Boiler#1 | Cemline | 2 | 20 life cycle | ||
| Boiler#2 | Cemline | 2 | 20 life cycle |
| SERC | |||||
| Manufacture | Model | Serial | Age | Recommendations | |
| Main Building | |||||
| Electric Boiler | Bryan | 165BHW4T6, KW165 | 99111 | 5 | |
| FHP #1 | FHP | WW420-4C5C | 3540-208-00001-T11M51559 | 5 | |
| FHP #2 | FHP | WW420-4C5C | 3540-208-00003-T111M51559 | 5 | |
| FHP #3 | FHP | WW420-4C5C | 3540-208-00004-T111M51559 | 5 | |
| FHP #4 | FHP | WW420-4C5C | 3540-208-00005-T111M51559 | 5 | |
| FHP #5 | FHP | WW420-4C5C | 3540-208-00006-T111M51559 | 5 | |
| FHP #6 | FHP | WW420-4C5C | 3540-208-00008-T111M51559 | 5 | |
| FHP #7 | FHP | WW420-4C5C | 3540-208-00002-T111M51559 | 5 | |
| FHP #8 | FHP | WW420-4C5C | 3540-208-00009-T111M51559 | 5 | |
| FHP #9 | FHP | WW420-4C5C | 3540-208-000011-T111M51559 | 5 | |
| FHP #10 | FHP | WW420-4C5C | 3540-208-00007-T111M51559 | 5 | |
| FHP #11 | FHP | WW420-4C5C | 3540-208-000010-T111M51559 | 5 | |
| FHP #12 | FHP | WW420-4C5C | 3540-208-000012-T111M51559 | 5 | |
| Admin Building | |||||
| Boiler (oil fired) | Burnham | V0A/V11 | V9003-1-04 | 12 | |
| Maintenance Shop | |||||
| Boiler (oil fired) | Burnham | V0A/V11 | 225.60.3 | 12 | |
| Manor House | |||||
| Boiler (oil fired) | Columbia | CSFH4150WLC | UDC19832 | 12 | |
| Schmidt Building | |||||
| Furnace | Trane | 4TXCD061BC3HCAA | N/A | 7 | |
| Furnace | Trane | 4TXCD061BC3HCAA | 9415JRM5G | 7 | |
| Furnace | Trane | 4TXCC037BC3HCAA | 9382ULF5G | 7 | |
| Furnace | Trane | 4TXCD061BC3HCAA | 9415JMT5G | 7 | |
| MSC | |||||
| Main Plant | Manufacture | Model | Serial | Age | Recommendations |
| Boiler #1 | Cleaver Brooks | CB200-250 | L-71336 | 2 | new |
| Boiler #2 | Cleaver Brooks | CB200-250 | L-71335 | 2 | new |
| Boiler #3 | Cleaver Brooks | CB200-250 | L-71337 | 2 | new |
| Storage 17 | |||||
| Boiler #1 | Weil McLain | CGA-7-PIDM | CP3942557 | 16 | 30 life cycle/OK |
| Boiler #2 | Weil McLain | CGA-7-PIDM | CP3942566 | 16 | 30 life cycle/OK |
| Greenhouse | 5 | ||||
| Boiler #1 | Raypak | H7-1253 | 910301783 | 7 | 15 year life cycle |
| Osteo Lab | Smith Cast Iron | 28A-7 | N94-412 | 10 | need to replace |
| POD5 | Fulton | VMP 130 | 101578 | 12 | |
| POD5 | Fulton | VMP 130 | 101578 | 12 | |
| CRC | |||||
| Boiler #1 | Donlee | SPLV-100 N/2 | 9720283 | 19 | Replace Burner |
| Boiler #2 | Donlee | SPLV-100 N/2 | 9720282 | 19 | Replace Burner |
| Boiler #3 | Peerless | LC10-SUP | 354272-200104 | 15 | Nonfunctioning |
| National Museum of African American History & Culture | |||||
| Hot Water Boiler | Fulton | VTG-4000LE | 8515 | 3 | |
| Hot Water Boiler | Fulton | VTG-4000LE | 8517 | 3 | |
| Hot Water Boiler | Fulton | VTG-4000LE | 8518 | 3 | |
| Hot Water Boiler | Fulton | VTG-4000LE | 8520 | 3 | |
| Hydronic Boiler (condensing) | Fulton | CAL-500 | 2013-1007 | 4 | |
| Hydronic Boiler (condensing) | Fulton | CAL-500 | 2013-1028 | 4 | |
| Steam Boiler | Fulton | ICT-30-LE | 116718 | 3 | |
| Steam Boiler | Fulton | ICT-30-LE | 116719 | 3 | |
| Steam Boiler | Fulton | ICT-30-LE | 116722 | 3 | |
| Water Heater | Aqua Plex | 1485L330A-TP | 0314137628 | 3 | |
| Water Heater | Aqua Plex | 1485L330A-TP | 0314137629 | 3 | |
| Cooper Hewitt | |||||
| Boiler #1 | RBI | CB1500 | 071262305 | 4 | Heat exchangers need replaced |
| Boiler #2 | RBI | CB1500 | 071262293 | 4 | Heat exchangers need replaced |
| Boiler #3 | RBI | CB1500 | 071262316 | 4 | Heat exchangers need replaced |
| Boiler #4 | RBI | CB1500 | 071262306 | 4 | Heat exchangers need replaced |
| Boiler | Fulton | 1CX-20 | PV279KK | 4 | relatively new and in shape |
Chiller ZOO 3001 Connecticut Ave NW Washington DC 20008
| Manufacture | Model | Serial | Age | Recommendations | |
| Panda House | McQuay | AGZ085BS27-ER11 | STNU040200144 | 12 | 20 year life cycle |
| Reptile House | Trane | RTHB150FMF00LW00MOUNN3LF2LFV00U0 | U97F02372 | 19 | Eddy Current |
| Reptile House | Trane | RTHB150FMF00LW00MOUNN3LF2LFV00U0 | U97E02368 | 19 | Eddy Current |
| Lion House | York | YCWZ77JMO/46PB | YLAM837755 | Approx. 23 | Eddy Current |
| Amazonia | Trane | Warranty | Should consider replacement due to age | ||
| Police | Westinghouse Condenser | 3808016---5 | 2092F99964 | 24 | Should consider replacement due to age |
| Police | Westinghouse AHU | AB100BIX | 353AI77G02 | 24 | Should consider replacement due to age |
| Police | Carrier Condenser | 38AE-016---500- - | 2092F99964 | 24 | Should consider replacement due to age |
| Police | Carrier AHU | 40RR-016---540- - | 2492F04619 | 24 | Should consider replacement due to age |
| Main Restaurant | Carrier | 30GXR083-A-640FZ | 0303F12153 | 13 | 20 year life cycle |
| Bird House | Trane | RTAA155G"YJ01R101BFG | E95U95J29818 | 21 | 20 year life cycle/should consider replacement |
| Research Building | BAC Tower | VFL103-F2 | U002061502 | 14 | 20 year life cycle |
| Research Building | BAC Tower | VTL103-KR | U002061501 | 14 | 20 year life cycle |
| Research Building | Trane | RTWA100AYE01C3DOWFN | U00K04474 | 16 | Eddy Current |
| Research Building | Trane | RTWA100AYE01C3DOWFN | U00K04472 | 16 | Eddy Current |
| Vet. Hospital | Trane | RTAC1404URONUAPNN1WX1TDNBA0EN11NR0EXN | U09B02991 | 7 | 20 year life cycle |
| Sea Lion | Trane | RTAC 1554 UFON UAFN L4NY 1TDN NNOE A11B ROEX N | U03J00B33 | 13 | 20 year life cycle |
| Sea Lion | Trane | RTAC 1554 UFON UAFN L4NY 1TDN NNOE A11B ROEX N | U03H00832 | 13 | 20 year life cycle |
| Sea Lion | York | YCAL002BEE46XEASDTXAXXRLXXXX45XX1XXXXXXVSXXXBXX1XXXXXNH5AXXX | SEXM-936420 | 23 | 20 year life cycle/ consider for replacement |
| General Services Building | Evapco | AT8-312B | 961176 | 20 | 20 |
| General Services Building | Trane | RTHB215FMD00LW0000UNN3LF2LFV00U0 | U96E04310 | 20 | Eddy Current |
| Chiller | York | YKHHGDJ1-CAF | SBNM-233350 | 1 | Eddy Current |
| Chiller | York | YKHHGDJ1-CAF | SBNM-233220 | 12 | Eddy Current |
| Renwick Gallery | 1661 Pennsylvania Ave NW |
Washington DC 20006
| Manufacture | Model | Serial | Age | Recommendations | |
| Chiller Module | MultiStack | MS50XGA2W1 | AA03256 | 13 | 15 year life cycle |
| Chiller Module | MultiStack | MS50XGA2W1 | AA03257 | 13 | 15 year life cycle |
| Natural History | 10th and Constitution Ave NW |
Washington DC 20560
| Manufacture | Model | Serial | Age | Recommendations | |
| Chiller #1 | Trane | CVHE112NA1M03GX257911E9X1C00000003A00000 | L92E13100 | 24 | 30 year life cycle/ controls are obsolate and need to be replaced |
| Chiller #2 | Trane | CVHE112NA1M03GX257911E9X1C00000003A00000 | L92E13101 | 24 | 30 year life cycle/ controls are obsolate and need to be replaced |
| Chiller #3 | Trane | CVHE112NA1M03GX257911E9X1C00000003A00000 | L92E12998 | 24 | 30 year life cycle/ controls are obsolate and need to be replaced |
| Chiller #4 | Trane | CVHE125NB1M03GX253931E9X1C9X1C0003A00000 | L92E12997 | 24 | 30 year life cycle Control where recently replaced/OK |
| Chiller #5 | Trane | CVHF108NE4A0FCZ289BEFECC1CC1C0000000Z01G000LS00004A100B | L10J04981 | 6 | 30 year life cycle |
| American History | 1400 Constitution Ave NW |
Washington DC 20013
| Manufacture | Model | Serial | Age | Recommendations | |
| Chiller #1 | York | YKVHTDJ3-DCFS | SNSM-761250 | 9 | Eddy Current |
| Chiller #2 | York | YKKKKMH9-CUFS | SMSM-761600 | 9 | Eddy Current |
| Chiller #3 | York | YKVHTDJ3-DCFS | SATM-810630 | 8 | Motor was replace 2017 |
| Chiller #4 | York | YKKKKMH9-CUFS | SMSM-761480 | 9 | Eddy Current |
| Anacostia | |||||
| 1901 Fort Place SE, MRC 777 |
Washington DC 20020
| Manufacture | Model | Serial | Age | Recommendations | |
| Chiller | McQuay | AGR100AS12-ER10 | STNU000400032 | 16 | 20 year life cycle/should consider replacement |
| Hazy | 14390 Air and Space Museum Parkway |
Chantilly, VA 20151
| Manufacture | Model | Serial | Age | Recommendations | |
| Chiller #1 | Trane | RTHC1D2F0H0G3L4G3MF0QUCD | U02C03685 | 14 | Eddy Current |
| Chiller #2 | Trane | RTHC1D2F0H0G3L4G3MF0QUCD | U02C03686 | 14 | Eddy Current |
| Chiller #3 | Trane | CVHF091FA1W0ACV308CA8ECC9A0000000WA1004C0000003A1 | L02C05225 | 14 | Eddy Current |
| Chiller #4 | Trane | CVHF091FA1W0ACV308CA8ECC9A0000000WA1004C0000003A1 | L02C05227 | 14 | Eddy Current |
| SERC | 647 Contees Wharf Rd |
Edgewater, MD 21037
| Manufacture | Model | Serial | Age | Recommendations | |
| Condenser | Trane | 4TTB3036B1000BA | 9421LU43F | 7 | |
| Condenser | Trane | 4TTB3060A1000BA | 9384W2D5F | 7 | |
| Condenser | Trane | 4TTB3060A1000BA | 9402JC22F | 7 | |
| Condenser | Trane | 4TTB3060A1000BA | 9384WU95F | 7 | |
| MSC | 4210 Silver Hill Rd |
Suitland, MD 20746-2863
| Manufacture | Model | Serial | Age | Recommendations | |
| Chiller | Trane | RTWD 080F 2O02 A1C1 AA2A 1A1Y 1B1A 400A 0010 000A 70A1 00D0 | U15C01502 | 1 | Eddy Current |
| Chiller | York | YKEREPQ4-CLG | SFTM-001460 | 8 | Eddy Current |
| Chiller | York | YKCQCSQ4-CJG | SBWM-509970 | 6 | Eddy Current |
| Chiller | York | YKEREPQ4-CLG | SEWM601480 | 6 | Eddy Current |
| POD-3 | York | ||||
| Chiller | York | YLAA0135SE46XAABXTCATXBLXCXX44SX1XXXHXXXSAXXXXX7XXXXXNDXAXXX | SHVM354010 | 7 | |
| POD-5 | York | ||||
| Chiller #1 | York | YCAV0227SA46VAABXTXXBXXLXXXX42SXXXXXHXXWSAXXXXX3XXXXXNBXAXXX | SFRM-263730 | 10 | |
| Chiller #2 | York | YCAV0227SA46VAABXTXXBXXLXXXX42SXXXXXHXXWSAXXXXX3XXXXXNBXAXXX | SFRM-263680 | 10 | |
| Chiller #3 | York | YCAV0187SA46VAABXTXXBXXLXXXX42SXXXXXHXXWSAXXXXX3XXXXXNBAXXX | SGRM-264410 | 10 | |
| CRC | 4220 Silver Hill Rd |
Suitland, MD 20746
| Manufacture | Model | Serial | Age | Recommendations | |
| Chiller | McQuay | PEH063-CCBC | 57G81075-00 | 19 | Overhaul & Eddy Current |
| Chiller | McQuay | PEH063-CCBC | 57G81071-00 | 19 | Overhaul & Eddy Current |
| NMAAHC | 1400 Constitution Ave NW |
Washington DC 20560
| Manufacture | Model | Serial | Age | Recommendations | |
| Chiller | York | YKFDFTQ7-EPG | SCBM-918410 | 3-4 | |
| Chiller | York | YKFDFTQ7-EPG | SCBM-918570 | 3-4 | |
| Chiller | York | YKFDFTQ7-EPG | SCBM-918730 | 3-4 | |
| American Indian | 1 Bowling Green |
New York, NY 10004
| Manufacture | Serial | Age | Recommendations | ||
| Chiller | York | YS CA CA S1 CHA | SFBM92-803842 | 24 | Replace due to age & obsolete refrigerant |
| Chiller | York | YS CA CA S1 CHA | SFMB928003581 | 24 | Replace due to age & obsolete refrigerant |
| Cooper Hewitt | 2 East 91 St |
New York, NY 10128
| Manufacture | Model | Serial | Age | Recommendations | |
| Chiller #1 | Trane | RTHB150ALD00LW00M0UNN2LF2LFV00U | U95M01650 | 21 | Replace due to age & obsolete refrigerant |
| Chiller #2 | Trane | RTHB150ALD00LW00M0UNN2LF2LFV00U | U95M01660 | 21 | Replace due to age & obsolete refrigerant |
| Module #1 | ArticChill | PWCCMV0250D3-MM | A001028112 | 4 | Relatively new and in shape |
| Module #2 | ArticChill | PWCCMV0250D3-MM | AA002028212 | 4 | relatively new and in shape |
| Module #3 | ArticChill | PWCCMV0250D3-MM | A002028312 | 4 | relatively new and in shape |
| Module #4 | ArticChill | PWCCMV0250D3-MM | A002028412 | 4 | relatively new and in shape |
| ZOO-VA | Smithsonian National Zoological Park |
1500 Remount Rd, Front Royal, VA 22630
ALL- Equipment Repairs Only-NTE VARIOUS