ATTACHMENT A4- GeneralCivilStructural Drawings.pdf
PDF 31 MB Posted
- Attached to
- Z1DA--Renovate Surgical Suite Phase II
- Solicitation number
- 36C24626R0039
About this file
This is a set of architectural and structural construction drawings for the Renovate Surgical Suite Phase II project at Salem VA Medical Center, Building 143, prepared by Miller-Remick LLC as the engineer of record with supporting consultants including PF&A Design (architecture), LaBella Associates (civil engineering), and Stanton Engineering Services (fire protection). The drawings are dated December 30, 2025, and include comprehensive design details for a fully sprinklered renovation project.
The project scope encompasses general civil and structural work including site demolition and erosion control, underground fuel tank replacement, new concrete equipment pads, waterline installation, and structural modifications to accommodate new mechanical systems. The architectural drawings detail life safety compliance for a healthcare facility including patient care areas, operating rooms, recovery rooms, and support spaces organized across basement and first-floor levels with specific fire-rating requirements (1-hour and 2-hour fire barriers), smoke compartmentalization, and infection control measures ranging from Class I to Class IV. Structural work includes new concrete foundations and equipment pads, structural steel framing for mechanical equipment support, HSS posts and bracing systems, roof-mounted equipment dunnage framing, and connection details for HVAC systems. The infection control matrix establishes construction protocols based on patient risk groups and construction type, with requirements for dust control, HEPA filtration, negative air pressure systems, and specialized cleaning procedures. Design standards comply with 2021 International Building Code, NFPA codes, and VA design manuals, with all structural steel conforming to AISC standards and concrete meeting 5,000 PSI compressive strength requirements.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NO. DESCRIPTION DATE
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
VA Drawing Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved by:
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
RENOVATE SURGICAL SUITE
PHASE II
SALEM VA MEDICAL CENTER
Jon Manninen, COR
2025-12-30
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
ENGINEER OF RECORD
M-R PROJECT NO: 0499-0136
CONSULTANTS
Civil Engineering:
LABELLA ASSOCIATES
Architecture:
PF&A DESIGN, P.C.
Project Number 658-19-103
Fire & Life Safety:
STANTON ENGINEERING SERVICES, LLC
GENERAL
COVER SHEET
GI001
MC/VRDJ
DRAWING INDEX
PROJECT CONSULTANTS
CODE REQUIREMENTSFIRE RATINGS
PATIENT RISK GROUP TABLE
GROUP 1
LOW RISK
GROUP 2
MEDIUM RISK
GROUP 3
HIGH RISK
GROUP 4
HIGHEST RISK
- ADMINISTRATIVE OFFICES
- PUBLIC CORRIDORS
- ELEVATORS
- DAY ROOMS
- CANTEEN RETAIL STORE
- VACANT WARDS OR VACANT
ICU'S ETC.
- OUTPATIENT, URGENT CARE
& PRIMARY CARE CLINICS
- LABORATORY
- CARDIOLOGY
- ECHOCARDIOGRAPHY
- ENDOSCOPY
- FOOD SERVICES
- INTERIM CARE & MEDICAL
UNITS
- NUCLEAR MEDICINE
- PHARMACY
- PHYSICAL THERAPY
- RADIOLOGY & NUCLEAR
MEDICINE
- RESPIRATORY THERAPY
- CCU
- EMERGENCY ROOM
- LABORATORY
- OUTPATIENT SURGERY
- PHARMACY
- POST ANESTHESIA CARE UNIT
- SURGICAL UNITS
- ANY AREA CARING FOR
IMMUNICOMPROMISED
PATIENTS
- SPD STORAGE /
STERILIZATION
- INTENSIVE CARE UNITS
- TB NEGATIVE PRESSURE
ISOLATION ROOMS
-OPERATING ROOM
INFECTION CONTROL MATRIX - CLASS OF PRECAUTIONS:
CONSTRUCTION PROJECT BY PATIENT RISK
PATIENT RISK GROUP
LOW RISK GROUP 1
MEDIUM RISK GROUP 2
HIGH RISK GROUP 3
HIGHEST RISK GROUP 4
TYPE A TYPE B TYPE C TYPE D
I
I
I
II
II
II
II
III/IV
II
II
III/IV
III/IV
III/IV
IV
IV
IV
CONSTRUCTION PROJECT TYPE
NOTE: INFECTION CONTROL APPROVAL WILL BE REQUIRED WHEN THE CONSTRUCTION ACTIVITY AND RISK LEVEL INDICATE THAT
CLASS III OR CLASS IV CONTROL PROCEDURES ARE NECESSARY.
1. EXECUTE WORK BY METHODS TO
MINIMIZE RAISING DUST FROM
CONSTRUCTION OPERATIONS.
2. IMMEDIATELY REPLACE A CEILING TILE
DISPLACED FOR VISUAL INSPECTIONS.
DURING CONSTRUCTION PROJECT UPON COMPLETION OF PROJECT
C L A
S
I
C L
A S
S
II
1. PROVIDE ACTIVE MEANS TO PREVENT
AIRBORNE DUST FROM DISPERSING INTO
ATMOSPHERE.
2.WATER MIST WORK SURFACES TO
CONTROL DUST WHILE CUTTING.
3.SEAL UNUSED DOORS WITH DUCT TAPE.
4.BLOCK OFF AND SEAL AIR VENTS.
5.PLACE DUST MAT AT ENTRANCE AND EXIT
OF WORK AREA.
6.REMOVE OR ISOLATE HVAC SYSTEM IN
AREAS WHERE WORK IS BEING
PERFORMED.
1.WIPE WORK SURFACES WITH DISINFECTANT.
2.CONTAIN CONSTRUCTION WASTE BEFORE
TRANSPORT IN TIGHTLY COVERED
CONTAINERS.
3.WIPE WORK SURFACES WITH DISINFECTANT,
WET MOP AND/OR VACUUM WITH HEPA
VACUUM BEFORE LEAVING WORK AREA.
4.REMOVE ISOLATION OF HVAC.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE FOLLOWING INFECTION CONTROL PRECAUTIONS
DEPENDING UPON THE AREA CLASS DESIGNATION
C L
A
II
I
C L A
IV
1.REMOVE OR ISOLATE HVAC SYSTEM IN AREA
WHERE WORK IS BEING DONE TO PREVENT
CONTAMINATION OF DUCT SYSTEM.
2.COMPLETE ALL CRITICAL BARRIERS, I.E.,
SHEETROCK, PLYWOOD, PLASTIC, TO SEAL
AREA FROM NON-WORK AREA OR IMPLEMENT
CONTROL CUBE METHOD (CART WITH PLASTIC
COVERING AND SEALED CONNECTION TO
WORK SITE WITH HEPA VACUUM FOR
VACUUMING PRIOR TO EXIT) BEFORE
CONSTRUCTION BEGINS.
3.MAINTAIN NEGATIVE AIR PRESSURE WITHIN
WORK SITE UTILIZING HEPA EQUIPPED AIR
FILTRATION UNITS.
4.CONTAIN CONSTRUCTION WASTE BEFORE
TRANSPORT IN TIGHTLY COVERED
CONTAINERS.
5.COVER TRANSPORT RECEPTACLES OR
CARTS. TAPE COVERING UNLESS SOLID LID.
1.DO NOT REMOVE BARRIERS FROM WORK
AREA UNTIL COMPLETED PROJECT IS
INSPECTED BY THE ENVIRONMENTAL HEALTH
AND SAFETY AND INFECTION CONTROL AND
THOROUGHLY CLEANED BY ENVIRONMENTAL
SANITATION SECTION.
2.REMOVE BARRIER MATERIALS CAREFULLY TO
MINIMIZE SPREADING OF DIRT AND DEBRIS
ASSOCIATED WITH CONSTRUCTION.
3.VACUUM WORK AREA WITH HEPA FILTERED
VACUUMS.
4.WET MOP AREA WITH DISINFECTANT.
5.REMOVE ISOLATION OF HVAC SYSTEM IN AREAS
WHERE WORK IS BEING PERFORMED.
1.OBTAIN INFECTION CONTROL PERMIT BEFORE
CONSTRUCTION BEGINS.
2. ISOLATE HVAC SYSTEM IN AREA WHERE WORK
IS BEING DONE TO PREVENT CONTAMINATION
OF DUCT SYSTEM.
3.COMPLETE ALL CRITICAL BARRIERS OR
IMPLEMENT CONTROL CUBE METHOD BEFORE
CONSTRUCTION BEGINS.
4.MAINTAIN NEGATIVE AIR PRESSURE WITHIN
WORK SITE UTILIZING HEPA EQUIPPED AIR
FILTRATION UNITS.
5.SEAL HOLES, PIPES, CONDUITS AND
PUNCTURES APPROPRIATELY.
6.CONSTRUCT ANTEROOM AND REQUIRE ALL
PERSONNEL TO PASS THROUGH THIS ROOM
SO THEY CAN BE VACUUMED USING A HEPA
VACUUM CLEANER BEFORE LEAVING WORK SITE
OR THEY CAN WEAR CLOTH OR PAPER
COVERALLS THAT ARE REMOVED EACH TIME
THEY LEAVE THE WORK SITE.
7.ALL PERSONNEL ENTERING WORK SITE ARE
REQUIRED TO WEAR SHOE COVERS.
1.DO NOT REMOVE BARRIERS FROM WORK
AREA UNTIL COMPLETED PROJECT IS
THOROUGHLY CLEANED BY ENVIRONMENTAL
MANAGEMENT.
2.VACUUM WORK AREA WITH HEPA FILTERED
VACUUMS.
3.WET MOP AREA WITH DISINFECTANT.
4.REMOVE BARRIER MATERIALS CAREFULLY
TO MINIMIZE SPREADING OF DIRT AND
DEBRIS ASSOCIATED WITH CONSTRUCTION.
5.CONTAIN CONSTRUCTION WASTE BEFORE
TRANSPORT IN TIGHTLY COVERED
CONTAINERS.
6.COVER TRANSPORT RECEPTACLES OR
CARTS. TAPE COVERING.
7.REMOVE ISOLATION OF HVAC SYSTEM IN
AREAS WHERE WORK IS BEING
PERFORMED.
DURING CONSTRUCTION PROJECT UPON COMPLETION OF PROJECT
Infection Control Risk Mitigation Recommendations Matrix of Precautions for Construction and Renovation
Type of Construction / Project Activity Table
TYPE A
Inspection and Non-Invasive Activities
Includes, but is not limited to:
-Removal of ceiling tiles for visual inspection limited to 20 Ln Ft tile per 160 sq. ft. space.
-Painting (but not sanding).
-Wall covering, electrical trim work, minor plumbing, and activities which do not generate dust or require cutting of walls or access to ceilings other than for visual inspection.
-Patching walls - not exceeding 8 sq. ft.
TYPE B
Small scale, short duration activities which create minimal dust.
Includes, but is not limited to:
-Installation of telephone and computer cabling.
-Access to chase spaces.
-Cutting of walls or ceiling where dust migration can be controlled.
-Patching walls - exceeding 8 sq. ft.
TYPE C
Work that generates a moderate to high level of dust or requires demolition or removal of any fixed building components and assemblies or new construction.
Includes, but is not limited to:
-Sanding of walls for painting or wall covering exceeding 32 sq. ft., or vacant areas.
-Removal of floor coverings, ceiling tiles and casework.
-New wall construction -Uncontained duct, HVAC or electrical work above ceilings.
-Major cabling activities.
-Any other project where high levels of dust are generated.
TYPE D
Major demolition and construction projects
Includes, but is not limited to:
-Activities that require consecutive work shifts -Requires heavy demolition or removal of a complete cabling system.
-New Construction.
UL SYSTEM HW-D-0262
FOR FLUTED STEEL DECK/
CONCRETE FLOOR ASSEMBLY
AND GYPSUM WALLBOARD WALL
1 &2 HR. RATING
JOINT WIDTH: 1" MAXIMUM
GYPSUM WALLBOARD/
STUD WALL ASSEMBLY
MAXIMUM 3" DEEP FLUTED
GALVANIZED STEEL DECK
WITH MINIMUM 2-1/2" THICK
REINFORCED CONCRETE
FLOOR.
TYPE A OR AS: MINIMUM 5/8" THICKNESS
OF FILL MATERIAL APPLIED WITHIN JOINT
OPENING ON EACH SIDE OF THE WALL,
FLUSH WITH EACH SURFACE OF THE WALL.
MINERAL WOOL INSULATION (MINIMUM
4.0 PCF) FIRMLY PRESSED INTO THE
FLUTES OF THE STEEL DECK AS A
PERMANENT FORM.
CONCRETE FLOOR
MINIMUM 4-1/2"
THICKNESS
2 HR. SPRAY ON FIREPROOFING
CONCRETE FLOOR
MINIMUM 4-1/2"
THICKNESS
IN 2 HR. FIRE-RATED WALL
ASSEMBLIES, FOAM BACKER
ROD FRICTION-FIT INTO JOINT
OPENING AND RECESSED A
MINIMUM 5/8" FORM EACH SURFACE
OF WALL.
MINERAL WOOL INSULATION (MINIMUM
4.0 PCF) FIRMLY PRESSED INTO THE
FLUTES OF THE STEEL DECK AS A
PERMANENT FORM.
TYPE X GYPSUM WALLBOARD/
STUD WALL ASSEMBLY
MAXIMUM 3" DEEP FLUTED
GALVANIZED STEEL DECK
WITH MINIMUM 2-1/2" THICK
REINFORCED CONCRETE
FLOOR.
UL SYSTEM HW-D-0262
FOR FLUTED STEEL DECK/
CONCRETE FLOOR ASSEMBLY
AND GYPSUM WALLBOARD WALL
1 &2 HR. RATING
JOINT WIDTH: 1" MAXIMUM
TYPE A OR AS: MINIMUM 5/8" THICKNESS
OF FILL MATERIAL APPLIED WITHIN JOINT
OPENING ON EACH SIDE OF THE WALL,
FLUSH WITH EACH SURFACE OF THE WALL.
2 HR SPRAY ON FIREPROOFING
DEAD END CORRIDOR
INTERIOR WALL AND CEILING REQUIREMENTS
INTERIOR FLOOR REQUIREMENTS
APPLICABLE CODES:
- NFPA-10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2018
- NFPA-70 NATIONAL ELECTRICAL CODE, 2008
- NFPA-99 HEALTHCARE FACILITIES CODE, 2021
- NFPA 101 LIFESAFETY CODE, 2021
- NFPA-220 STANDARD TYPE OF BUILDING CONSTRUCTION, 2021
PG 18-12 -SURGICAL AND ENDOVASCULAR SERVICES DESIGN GUIDE APRIL 2016 (REV 08/23)
PG 18-14 -ROOM FINISHES, DOOR & HARDWARE SCHEDULE
VA FIRE PROTECTION DESIGN MANUAL 9TH EDITION NOVEMBER 2023
NFPA 101
BUILDING AREA
BUILDING OCCUPANCY CLASSIFICATION
TYPE OF CONSTRUCTION
BUILDING HEIGHT
FIRE SUPPRESSION SYSTEM
INTERIOR FINISHES
OCCUPANT LOAD
EXITS - MINIMUM NUMBER REQUIRED
STAIRWAY WIDTH
BUILDING STORIES
HEALTHCARE (EXISTING)
TYPE I (3, 3, 2)
NFPA 13 SPRINKLER SYSTEM
CONSTRUCTION ELEMENTS
INTERIOR
HOURS
TYPE I ( 3,3,2)
EXTERIOR
GENERAL NOTES:
1) ALL RATED INTERIOR PARTITION SHOULD BE CONSTRUCTED IN ACCORDANCE
WITH THE RATED PARTITION SCHEDULE UNLESS NOTED OTHERWISE ON THE FLOOR
PLANS
CONSTRUCTION TYPE
APPLICABLE CODE EXCERPTS :
1. ALL REQUIRED HANDRAILS,
GUARDS, AND GRAB BARS SHALL
BE DESIGNED AND CONSTRUCTIED
TO THE STRUCTURAL LOADING
CONDITIONS IN SECTION 4.4 OF
ACSE 7.
CLASS B
NFPA 101, 10.2.8.1
CLASS B OR C = SPACES < 4 PEOPLE
FINISHES 48"H MAX AFF
NFPA 101, 10.2.8.1
SUPPORTING MORE THAN ONE FLOOR,
COLUMNS, OR OTHER BEARING WALLS
SUPPORTING ONE FLOOR ONLY
PLUMBING FIXTURES
CORRIDORS I-2 BED MOVEMENT = 96 INCHES
CORRIDOR ACCESS (MIN.) = 60 INCHES
CLASS II OR A MINIMUM CRITICAL RADIANT FLUX OF
0.1 W/SQ CM (NFPA 101,10.2.8.2)
CORRIDOR WIDTH
EGRESS CLEAR WIDTH NFPA 101, 7.3.3.1 (1005.3.2)
UNLIMITED
30 FT. SPRINKLED (NFPA 101,18.2.5.2)
COMMON PATH OF TRAVEL 100 FT. SPRINKLED (NFPA 101,18.2.5.3)
TRAVEL DISTANCE 200 FT. SPRINKLED (NFPA 101,18.2.6.2.1)
• AMBULATORY (100 SF/OCC)
- 20,728 NSF
- 208 OCCUPANT
• UNCONCENTRATED ASSEMBLY (15 SF/OCC)
- 185 NSF
- 13 OCCUPANT
• STORAGE AND MECHANICAL (300 SF/OCC)
- 1,876 NSF
- 7 OCCUPANT
• TOTAL OCCUPANT LOAD = 228 OCCUPANTS
(TABLE 7.3.1.2)
AREA OF REFUGE
NFPA 101, 18.3.3.2
SEPARATION DISTANCE OF EXITS
(OVERALL DIAGONAL OF THE AREA SERVED)
2 REQ < 500 OCCUPANTS. (NFPA 101, 7.4.1.1)
1/3 L - SPRINKLERED (NFPA 101,7.5.1.3.3)
1/2 L - NON-SPRINKLERED (NFPA 101,7.5.1.3.2)
N/A
STAIR CLEAR WIDTH (1005.3.1)
SMOKE COMPARTMENTS
SIZE
TRAVEL DISTANCE
ASSEMBLY RATINGS:
WALLS, DOORS, GLAZING
CAN BE UP TO 40,000 SF MAX SINCE NO PATIENT
SLEEPING ROOMS ARE IN THE RENOVATION SMOKE
ZONE - 22,500 SF MAX (NFPA 101, 18.3.7.1.3)
WALL - "SMOKE BARRIER" 1 HOUR
DOOR - 1/3 HOUR (PROVIDE CLOSER 18.3.7.8.1)
GLAZING - 3/4 HOUR
(NFPA 101,TABLE 8.3.3.2.2)
SUITES
SIZE
TRAVEL DISTANCE
ASSEMBLY RATINGS:
WALLS, DOORS, GLAZING
NUMBER OF EXITS
10,000 SF MAX - SMOKE DEDECTION (18.2.5.7.2.3.C)
100 FT. TO SUITE EXIT ACCESS DOOR (NFPA 101,
18.2.5.7.2.4.A AND 18.2.5.7.3.3.A)
2 REQUIRED > 1000 SF (NFPA 101,18.2.5.7.2.2.B)
• WALL - "SMOKE PARTITION" (NFPA 101, 18.2.5.7.1.2 AND
18.3.6.2)
• DOOR - CLOSER NOT REQUIRED (NFPA 101, 18.3.6.3)
*SEAL ASSEMBLIES TO LIMIT PASSAGE OF SMOKE
SLEEPING
NON-SLEEPING
SLEEPING
NON-SLEEPING 2 REQUIRED > 2500 SF (NFPA 101,18.2.5.7.3.2.B)
FIRE WALL LABELING
FIRE EXTINGUISHER
TYPE
TRAVEL DISTANCE
2-A (TABLE 6.2.1.1)
75 FT. (TABLE 6.2.1.1)
200 FT. (NFPA 101,18.2.6.2.1)
BEARING WALLS
SUPPORTING A ROOF ONLY 3
SUPPORTING MORE THAN ONE FLOOR,
COLUMNS, OR OTHER BEARING WALLS
SUPPORTING A ROOF ONLY 2
SUPPORTING ONE FLOOR ONLY
SUPPORTING MORE THAN ONE FLOOR,
COLUMNS, OR OTHER BEARING WALLS
SUPPORTING ONE FLOOR ONLY
SUPPORTING A ROOF ONLY
COLUMNS
SUPPORTING MORE THAN ONE FLOOR,
COLUMNS, OR OTHER BEARING WALLS
SUPPORTING ONE FLOOR ONLY
SUPPORTING A ROOF ONLY
BEAMS,
GIRDERS,
TRUSSES AND
ARCHES
FLOOR / CEILING ASSEMBLIES 2
ROOF / CEILING ASSEMBLIES 1 1/2
INTERIOR NONBEARING WALLS 0
EXTERIOR NONBEARING WALLS 0
30'-4'' (ETR)
22,920 DGSF
N/A
N/A
164*.2=33'' , 36''
MINIMUM APPLIES - APPEARS TO BE 168'' PROVIDED
SEE SHEET GI006 FOR OCCUPANT LOAD PLAN
15,000 SF MAX - SMOKE DEDECTION (NFPA 101, 18.2.5.7.2.3.2.B)
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved by:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD PF&A DESIGN, P.C.
REGISTERED ARCHITECTCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER
one eighth inch = one foot one quarter inch = one foot three eigths inch = one foot one half inch = one foot three quarter inch = one foot
6" 0 one inch = one foot
6" 0 one and one half inch = one foot
6" 0 three inch = one foot
6"
Architecture:
PF&A DESIGN, P.C.
GENERAL INFORMATION
M-R PROJECT NO:0499-0136
Jon Manninen, COR
VA Drawing Number
Project Number
Civil Engineering:
LABELLA ASSOCIATES
Fire Protection:
STANTON ENGINEERING SERVICES, LLC
/2 /2
:4
:1
A M
GI002
RENOVATE SURGICAL SUITE
PHASE II
SALEM VA MEDICAL CENTER
2025-12-30 DJP MAT
BID DOCUMENTS
FULLY SPRINKLERED
BUILDING REGULATION DATA & ICRA NOTES
658-19-103
2025−12−30
ALL WORK ON 1ST FLOOR IS CONSTRUCTION TYPE D, RISK GROUP 4, CLASS DESIGNATION IV
ALL WORK IN THE BASEMENT IS CONSTRUCTION TYPE C, RISK GROUP 1,CLASS DESIGNATION II
GI002 1 1/2" = 1'-0"
1 FIRE STOPPING DETAIL
GI002 1 1/2" = 1'-0"
2 FIRE STOPPING DETAIL - TOP OF WALL
NO.
A I
N I
G
RI
V
FOHTLA
E W
N O
M M
O
C JOSEPH H. TROST
ARCHITEC
T
Revisions: Date:
A B C D E F G H I
J K L
E E
E
TRAVEL DISTANCE = 146'-0"
TRAVEL DISTANCE = 142'-0"
TRAVEL DISTANCE = 118'-4"
OR-2
1D-125
OR-3 ROBOTIC
1D-126
OR-4 ROBOTIC
1C-128
CORRIDOR
C1-18
OR-6
1C-130
ORTHO STOR
1C-125
PRE-OP
1C-105
CLEAN
1C-118
LOUNGE
1C-114A
TOILET
1C-114B
ISOLATION
1C-116
NURSE STATION
1C-115A
SOILED
1C-119
OFFICE
1C-155
OFFICE
1C-154
OFFICE
1C-153
OFFICE
1C-152
EXIST. WAITING
1C-150
HAC
1C-108
MEDS
1C-113
EQUIPMENT
1C-111 STORAGE
1C-110
ANTE
1C-117
CORRIDOR
C1-15
CORRIDOR
C1-3
OR-1 HYBRID
1D-123
CONTROL ROOM
1D-124
IT
1D-120
EQUIPMENT
1D-121
PUMP
1D-122
EQUIPMENT
STORAGE
1C-136
HE
HE
T R
A V
E L
D
IS
T A
N C
E
T R
A V
E L
D
IS
T A
N C
E
STORAGE
1C-124
SOILED
1C-142
CYLINDER
STORAGE
1C-143
PACU
1C-115
NURSE
1C-105A
LINEN CLOSET
COMM CTR
1C-106
CORRIDOR
C1-16
CORRIDOR
C1-17
CORRIDOR
C1-19
OR-7
1C-129
ANESTHESIA
WORKROOM
1C-127
HAC
1C-122
LINEN ALCOVE
1C-123
EQUIPMENT
ALCOVE
CORRIDOR
C1-9
CORRIDOR
C1-14
CLEAN CORE
1C-120
OR-5 ORTHO
1C-131
CORRIDOR
C1-12
CORRIDOR
C1-11
TOILET
1C-109
LOCKERS
1C-114C
OFFICE
1C-151
STAIR
S-8
COMMON PATH = 57'-0"
NURSE/ COMM
CENTER
1C-156
TRAVEL DISTANCE = 138'-0"
OFFICE
1C-157
LOUNGE
D-C192
TOILET
D-C193
TOILET
D-C194
TOILET / SHOWER
D-C191
MECH RM
IC-132
WORK RM
1C-129H
CONFERENCE RM
1C-129J
COMMON SPACE
1C-129
OFFICE
1C-129Q
OFFICE
1C-129P
OFFICE
1C-129L
OFFICE
1C-129M
WAITING
1C-129K
MECH
1B-120
IRM
1B-121
ELEC
1B-122
ON-CALL
1B-123
TLT
1B-124
TLT
1B-125
CLEAN
1B-119
FIRE EXTINGUISHER CABINET
FEC
REQUIRED EXIT E
LIFE SAFETY LEGEND
X' - X"
MAX TRAVEL DISTANCE 200'TRAVEL DISTANCE
HORIZONTAL EXIT HE
COMMON PATH
X' - X"
MAX TRAVEL DISTANCE 100'
EXIT SIGN
** SEE ELECTRICAL PLANS FOR EXIT SIGN ORIENTATION**
**HORIZONTAL EXIT LOCATIONS BASED ON RECORD DRAWINGS RECEIVED FROM VA
WALL LEGEND
1 HR. FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
2 HR.FIRE BARRIER
1 HR FIRE BARRIER AND SMOKE BARRIER
(BOTH WALL TYPES APPLY)
PATIENT ROOM
D-D116
PATIENT ROOM
D-D115
PATIENT ROOM
D-D112
PATIENT ROOM
D-D111
PATIENT RM
D-D110
PATIENT RM
D-D109
PATIENT RM
D-D108
PCU ROOM
D-D1001
PCU RM
D-D1002
ON CALL
D-D1004
STORAGE
D-D1003
ANTE
D-D1002A
TOILET
D-C159
NURSING
STATION
D-C160
CORRIDOR
D-C161
CLEAN
D-D1029
SOILED HOLDING
D-D1028
ELECTRICAL
D-D1027
IRM
D-C165
RECOVERY CCLO
D-D101
MEDS
D-D1030
STORAGE
D-C168
NOURISHMENT
D-D1031
TOILET
D-C1005
WAITING
D-C1006
TOILET
D-C172
OFFICE
D-C173
ELECTRICAL
D-C175
CORRIDOR
D-C177
GROUP OFFICE
D-C1015
PCU OFFICE
D-C1007
PCU OFFICE
D-C1008
PCU EQUIPMENT
D-C1009
WORK ROOM
D-C1010
PCU LOUNGE /
LOCKERS
D-C1012
ELEV
D-C186
OFFICE
D-C1019
OFFICE
D-C1018
LOGISTICS
D-C1020
CORRIDOR
XC
STAIR
XB
HOUSEKEEPING
D-C103
ELECTRICAL
D-C198
OFFICE
D-C190
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved by:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD PF&A DESIGN, P.C.
REGISTERED ARCHITECTCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER
one eighth inch = one foot one quarter inch = one foot three eigths inch = one foot one half inch = one foot three quarter inch = one foot
6" 0 one inch = one foot
6" 0 one and one half inch = one foot
6" 0 three inch = one foot
6"
Architecture:
PF&A DESIGN, P.C.
GENERAL INFORMATION
M-R PROJECT NO:0499-0136
Jon Manninen, COR
VA Drawing Number
Project Number
Civil Engineering:
LABELLA ASSOCIATES
Fire Protection:
STANTON ENGINEERING SERVICES, LLC
/2 /2
:4
:3
A M
GI003
RENOVATE SURGICAL SUITE
PHASE II
SALEM VA MEDICAL CENTER
2025-12-30 DJP MAT / SKC
BID DOCUMENTS
FULLY SPRINKLERED
LIFE SAFETY PLAN
FIRST FLOOR - OVERALL 658-19-103
2025−12−30
SCALE: 3/32" = 1'-0"1 FIRST FLOOR PLAN - LIFE SAFETY
BUILDING 143
KEY PLAN
PLAN
NORTH
PHASE 2
PHASE 1
PHASE 3
PHASE 3
PHASE 4
ACTUAL
NORTH
NO.
A I
N I
G
RI
V
FOHTLA
E W
N O
M M
O
C JOSEPH H. TROST
ARCHITEC
J K L
E
E
OR-2
1D-125
OR-3 ROBOTIC
1D-126
OR-4 ROBOTIC
1C-128
ORTHO STOR
1C-125
OR-6
1C-130
OR-1 HYBRID
1D-123
CONTROL ROOM
1D-124
IT
1D-120
EQUIPMENT
1D-121
PUMP
1D-122
SOILED
1C-142
CYLINDER
STORAGE
1C-143
EALLOWABLE TRAVEL DISTANCE = 200'-0"
ACTUAL TRAVEL DISTANCE = 118'-4"
HE
HE
A L
L O
W A
B L
E T
R A
V E
L D
IS
T
A N
C E
A C
T U
A L
T R
A V
E L
D
IS
T A
N C
E
A L
L O
W A
B L
E T
R A
V E
L D
IS
T
A N
C E
A C
T U
A L
T R
A V
E L
D
IS
T A
N C
E
ALLOWABLE TRAVEL DISTANCE = 200'-0"
ACTUAL TRAVEL DISTANCE = 142'-0"
OFFICE
IC-119
OFFICE
IC-120
OFFICE
IC-121
PACU
EQUIPMENT
IC-118
HK
IC-159
TOILET
IC-109
WAITING
IC-111
SOILED
IC-125
TLT
IC-1005
PRE OP
IC-106
CLEAN
IC-157
NURSE/COMM
CNTR
IC-105
LOCKERS
IC-107
OR-7
1C-129
CLEAN CORE
1C-120
CLEAN CORE
1C-120
EQUIPMENT
STORAGE
1C-136
HAC
1C-122
LINEN ALCOVE
1C-123
STORAGE
1C-124
OR-5 ORTHO
1C-131
ANESTHESIA
WORKROOM
1C-127
ALLOWABLE TRAVEL DISTANCE = 200'-0"
ACTUAL TRAVEL DISTANCE = 121'-0"
NURSE/ COMM
CENTER
1C-156
OFFICE
1C-157
MECH RM
IC-132
LOUNGE
D-C192
TOILET
D-C193
TOILET
D-C194
WORK RM
1C-129H
COMMON SPACE
1C-129
OFFICE
1C-129Q
CONFERENCE RM
1C-129J
WAITING
1C-129K
OFFICE
1C-129L
OFFICE
1C-129M
OFFICE
1C-129P
MECH
1B-120
CLEAN
1B-119
IRM
1B-121
ELEC
1B-122
ON-CALL
1B-123
TLT
1B-124
TLT
1B-125
FIRE EXTINGUISHER CABINET
FEC
REQUIRED EXIT E
LIFE SAFETY LEGEND
X' - X"
MAX TRAVEL DISTANCE 200'TRAVEL DISTANCE
HORIZONTAL EXIT HE
COMMON PATH
X' - X"
MAX TRAVEL DISTANCE 100'
EXIT SIGN
** SEE ELECTRICAL PLANS FOR EXIT SIGN ORIENTATION**
**HORIZONTAL EXIT LOCATIONS BASED ON RECORD DRAWINGS RECEIVED FROM VA
WALL LEGEND
1 HR. FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
2 HR.FIRE BARRIER
1 HR FIRE BARRIER AND SMOKE BARRIER
(BOTH WALL TYPES APPLY)
PATIENT ROOM
D-D116
PATIENT ROOM
D-D115
PATIENT ROOM
D-D112
PATIENT ROOM
D-D111
PATIENT RM
D-D110
PATIENT RM
D-D109
PATIENT RM
D-D108 PCU ROOM
D-D1001
PCU RM
D-D1002
ON CALL
D-D1004
STORAGE
D-D1003
ANTE
D-D1002A
TOILET
D-C159
NURSING
STATION
D-C160
CORRIDOR
D-C161
CLEAN
D-D1029
SOILED HOLDING
D-D1028
ELECTRICAL
D-D1027
IRM
D-C165
RECOVERY CCLO
D-D101
MEDS
D-D1030
STORAGE
D-C168
NOURISHMENT
D-D1031
TOILET
D-C1005
WAITING
D-C1006
TOILET
D-C172
OFFICE
D-C173
ELECTRICAL
D-C175
CORRIDOR
D-C177
GROUP OFFICE
D-C1015
PCU OFFICE
D-C1007
PCU OFFICE
D-C1008
PCU EQUIPMENT
D-C1009
WORK ROOM
D-C1010
PCU LOUNGE /
LOCKERS
D-C1012
ELEV
D-C186
OFFICE
D-C1019
OFFICE
D-C1018
LOGISTICS
D-C1020
CORRIDOR
XC
STAIR
XB
HOUSEKEEPING
D-C103
ELECTRICAL
D-C198
ISOLATION ROOM
D-C117
ANTE
D-C119
OFFICE
D-C118
ANEST OFFICE
D-C116
BREAK RM
D-C113
RECOVERY
D-C13A
BIOHAZARD
D-C111
WAITING ROOM
D-C110
NURSE STATION
DC-12
PACU
DC-11
TOILET
D-C114
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved by:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD PF&A DESIGN, P.C.
REGISTERED ARCHITECTCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER
one eighth inch = one foot one quarter inch = one foot three eigths inch = one foot one half inch = one foot three quarter inch = one foot
6" 0 one inch = one foot
6" 0 one and one half inch = one foot
6" 0 three inch = one foot
6"
Architecture:
PF&A DESIGN, P.C.
GENERAL INFORMATION
M-R PROJECT NO:0499-0136
Jon Manninen, COR
VA Drawing Number
Project Number
Civil Engineering:
LABELLA ASSOCIATES
Fire Protection:
STANTON ENGINEERING SERVICES, LLC
/2 /2
:4
:4
A M
GI004
RENOVATE SURGICAL SUITE
PHASE II
SALEM VA MEDICAL CENTER
2025-12-30 DJP MAT / SKC
BID DOCUMENTS
FULLY SPRINKLERED
LIFE SAFETY PLAN - BID DEDUCT
658-19-103
2025−12−30
SCALE: 3/32" = 1'-0"1 FIRST FLOOR PLAN - LIFE SAFETY - BID DEDUCT
BUILDING 143
KEY PLAN
PLAN
NORTH
PHASE 2
PHASE 1
PHASE 3
PHASE 3
PHASE 4
ACTUAL
NORTH
NO.
A I
N I
G
RI
V
FOHTLA
E W
N O
M M
O
C JOSEPH H. TROST
ARCHITEC
CR
CR
OL
CR
CR
CR
AO
SL
CR
AO
OL OL OL
CR
AO
SL
OL
CR
CR
CR
AO
CR
CR
OL
CR
CR
CR
AO
SL
CR
AO
OL OL OL
CR
AO
SL
OL
CR
CR
CR
CR
AO
SUITES INFORMATION
WALL LEGEND
1 HR. FIRE BARRIER
SMOKE BARRIER
SMOKE PARTITION
2 HR.FIRE BARRIER
1 HR FIRE BARRIER AND SMOKE BARRIER
(BOTH WALL TYPES APPLY)
5021 SF
EXISTING SLEEPING
SUITE
2981 SF
SUITE
4777 SF
SLEEPING SUITE
9800 SF
SUITE
95' TRAVEL DISTANCE
92' TRAVEL
DISTANCE
HE
' T R
A V
E L
D
IS
T A
N C
E
HE
96' TRAVEL
DISTANCE
85' TRAVEL
DISTANCE
60' TRAVEL
DISTANCE
HE 83' TRAVEL
DISTANCE
1987 SF
SUITE
12106 SF
SUITE
23731 SF
SMOKE
COMPARTMENT
95' TRAVEL DISTANCE
95' TRAVEL
DISTANCE
HE
' T R
A V
E L
D
IS
T A
N C
E
HE
105' TRAVEL
DISTANCE
140' TRAVEL
DISTANCE
85' TRAVEL
DISTANCE
90' TRAVEL
DISTANCE
HE
8585 SF
SMOKE
COMPARTMENT
2252 SF
SMOKE
COMPARTMENT
11242 SF
SMOKE
COMPARTMENT
21437 SF
SMOKE
COMPARTMENT
4866 SF
SMOKE
COMPARTMENT
6708 SF
SMOKE
COMPARTMENT
2515 SF
SMOKE
COMPARTMENT
2250 SF
SMOKE
COMPARTMENT
SUITES 18.2.5.7.1
SUITE SEPARATION SHALL BE CONSTRUCTED IN ACCORDANCE IN 18.3.6.2 - CORRIDOR WALLS.
PATIENT CARE NON SLEEPING SUITES MAXIMUM SIZE 12,500 SF. (18.2.5.7.3)
NON SLEEPING SUITES REQUIRE 2 EXIT ACCESS DOORS IF MORE THAN 2500 SF (18.2.5.7.3.2)
ONE MEANS OF EGRESS SHALL BE DIRECT TO A CORRIDOR OR AN EXIT STAIR.
ONE MEANS OF EGRESS SHALL BE PERMITTED TO BE INTO ANOTHER SUITE.
TRAVEL DISTANCE WITHIN A NON SLEEPING TO AN EXIT ACCESS SHALL NOT EXCEED 100 FEET (18.2.5.7.3.4A)
TRAVEL DISTANCE WITHIN A NON SLEEPING SUITE TO AN EXIT SHALL NOT EXCEED 200 FEET (18.2.5.7.3.4.B)
FIRE EXTINGUISHER CABINET
FEC
REQUIRED EXIT E
LIFE SAFETY LEGEND
X' - X"
MAX TRAVEL DISTANCE 200'TRAVEL DISTANCE
HORIZONTAL EXIT HE
COMMON PATH
X' - X"
MAX TRAVEL DISTANCE 100'
EXIT SIGN
** SEE ELECTRICAL PLANS FOR EXIT SIGN ORIENTATION**
**HORIZONTAL EXIT LOCATIONS BASED ON RECORD DRAWINGS RECEIVED FROM VA
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved by:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD PF&A DESIGN, P.C.
REGISTERED ARCHITECTCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER
one eighth inch = one foot one quarter inch = one foot three eigths inch = one foot one half inch = one foot three quarter inch = one foot
6" 0 one inch = one foot
6" 0 one and one half inch = one foot
6" 0 three inch = one foot
6"
Architecture:
PF&A DESIGN, P.C.
GENERAL INFORMATION
M-R PROJECT NO:0499-0136
Jon Manninen, COR
VA Drawing Number
Project Number
Civil Engineering:
LABELLA ASSOCIATES
Fire Protection:
STANTON ENGINEERING SERVICES, LLC
/2 /2
:4
:5
A M
GI005
RENOVATE SURGICAL SUITE
PHASE II
SALEM VA MEDICAL CENTER
2025-12-30 DJP MAT / SKC
BID DOCUMENTS
FULLY SPRINKLERED
SMOKE COMPARTMENT & SUITE PLANS
FIRST FLOOR 658-19-103
2025−12−30
BUILDING 143
KEY PLAN
PLAN
NORTH
PHASE 2
PHASE 1
PHASE 3
PHASE 3
PHASE 4
ACTUAL
NORTH
SCALE: 1" = 20'-0"3 FIRST FLOOR PLAN - SUITE
SCALE: 1" = 20'-0"2 FIRST FLOOR NEW SMOKE COMPARTMENT PLAN
SCALE: 1" = 20'-0"1 FIRST FLOOR EXISTING SMOKE COMPARTMENT PLANS
NO.
A I
N I
G
RI
V
FOHTLA
E W
N O
M M
O
C JOSEPH H. TROST
ARCHITEC
J K L
404 SF
MES
86 SF
MES
333 SF
MES
151 SF
MES
59 SF
MES
86 SF
MES
177 SF
MES 185 SF
UNCONCENTRATED
ASSEMBLY
18 SF
MES
297 SF
MES
OCCUPANT LOAD LEGEND
(MES) MECHANICAL,
ELECTRICAL AND STORAGE
AMBULATORY HEALTHCARE
UNCONCENTRATED ASSEMBLY
265 SF
MES
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved by:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD PF&A DESIGN, P.C.
REGISTERED ARCHITECTCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER
one eighth inch = one foot one quarter inch = one foot three eigths inch = one foot one half inch = one foot three quarter inch = one foot
6" 0 one inch = one foot
6" 0 one and one half inch = one foot
6" 0 three inch = one foot
6"
Architecture:
PF&A DESIGN, P.C.
GENERAL INFORMATION
M-R PROJECT NO:0499-0136
Jon Manninen, COR
VA Drawing Number
Project Number
Civil Engineering:
LABELLA ASSOCIATES
Fire Protection:
STANTON ENGINEERING SERVICES, LLC
/2 /2
:4
:5
A M
GI006
RENOVATE SURGICAL SUITE
PHASE II
SALEM VA MEDICAL CENTER
2025-12-30 DJP MAT / SKC
BID DOCUMENTS
FULLY SPRINKLERED
OCCUPANT LOAD PLAN
FIRST FLOOR 658-19-103
2025−12−30
BUILDING 143
KEY PLAN
PLAN
NORTH
PHASE 2
PHASE 1
PHASE 3
PHASE 3
PHASE 4
ACTUAL
NORTH
SCALE: 3/32" = 1'-0"1 FIRST FLOOR PLAN - OCCUPANT LOAD
NO.
A I
N I
G
RI
V
FOHTLA
E W
N O
M M
O
C JOSEPH H. TROST
ARCHITEC
SOIL: 41C
HSG: B
W W
W W
E
E
E
E
E
E
E
E E
E
E E E E
E E
E
E
E
E
E
E
E E
E
E
E
E
E
T
T T
T
T T
T
T
T
T T T
T T
T T
T
T
T
T T
T
T
T
T
T
ST
ST
ST
ST
ST
G
G G
G
GG
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
NO. DESCRIPTION DATE
on e ei gh th in ch o ne fo ot th re e in ch es o ne fo ot 6"
6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot
6"
6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot 4 on e qu ar te r i nc h on e fo ot
VA FORM 08-6231
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
VA Drawing Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved by:
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
RENOVATE SURGICAL SUITE
PHASE II
SALEM VA MEDICAL CENTER
Jon Manninen, COR
2025-12-30
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
ENGINEER OF RECORDCONSULTANTS
Civil Engineering:
LABELLA ASSOCIATES
Architecture:
PF&A DESIGN, P.C. Project Number 658-19-103
Fire & Life Safety:
STANTON ENGINEERING SERVICES, LLC
JJP EBP
PLAN
NORTH
ACTUAL
NORTH
0' 10' 20' 30'
SCALE 1" = 10'
12/30/2025
C-100
EXISTING CONDITIONS
EXISTING CONDITIONS:
SYMBOLS:
LEGEND
EXISTING CONDITIONS AS SHOWN BY FIELD SURVEY COMPLETED BY ACCUPOINT
SURVEYING & DESIGN, LLC DATED 10/07/2025. SUBSURFACE RADAR SURVEY
COMPLETED BY AMERIMARK LOCATE DATED 10/06/2025.
CIVIL
C-100
1 EXISTING CONDITIONS PLAN
SCALE: 1" = 10'
W
W W
E
E
E
E
E
E
E
E E
E
E E E E
E E
E
E E
E
E
E
E
E
T
T T
T T
T
T
T
T T T
T T
T T
T T
T
T
G
G G
G
GG
SS
SS
REMOVE AND DISPOSE OF EXISTING CONCRETE SLABS AND
UNDERGROUND FUEL TANKS. IN THE EVENT OF A SUPPOSED
LEAK OR FUEL DISCHARGE, NOTIFY PROJECT ENVIRONMENTAL
INSPECTOR IMMEDIATELY.
REMOVE AND DISPOSE OF ASSOCIATED UNDERGROUND PIPING,
VENTS, AND ELECTRICAL LINES.
FULL-DEPTH ASPHALT SAWCUT LIMITS, REMOVE AND DISPOSE OF
EXISTING ASPHALT PAVEMENT.
REMOVE AND DISPOSE OF EXISTING CONCRETE CURB AND
GUTTER AT NEAREST JOINT LINES.
EXISTING SITE FEATURE TO BE REMOVED
APPROX. SAWCUT LIMITS
REMOVE UNDERGROUND UTILITY
REMOVE ASPHALT PAVEMENT MATERIAL
REMOVE CONCRETE PAVEMENT
MATERIAL
REMOVE AND DISPOSE OF EXISTING CONCRETE SIDEWALK AT
NEAREST JOINT LINES. SAWCUT AT CRACK CONTROL LINES IF
NECESSARY.
SALVAGE AND PROTECT EXISTING TRASH CAN AND BENCH AND
RETURN TO OWNER. REPLACE AT THE OWNER'S DISCRETION
AFTER CONSTRUCTION IS COMPLETED.
DEMOLITION KEY NOTES & LEGEND
LINETYPE/BLOCK DESCRIPTION
W W
W W
E
E
E
E
E
E
E
E E
E
E E E E
E E E
E E
E
E
E
E
E
T
T T
T T
T
T
T
T T T
T T
T T
T T
T
T
G
G G
G
GG
SS
SS
SF
LODLODLOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD LOD
LOD
LOD
LOD LOD LOD LOD
LOD
LOD
LOD
LODLODLODLOD
SF
SF
SF
SF SF SF
SF
SF
SF
SF
SF
SF
IP
CE
TP
PROTECT
EXISTING TREE
ESC LIMITS OF
DISTURBANCE,
±0.14 AC (6,280 SQFT)
TP
PROTECT EXISTING
BUSHES
NO. DESCRIPTION DATE
on e ei gh th in ch o ne fo ot th re e in ch es o ne fo ot 6"
6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot
6"
6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot 4 on e qu ar te r i nc h on e fo ot
VA FORM 08-6231
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
VA Drawing Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved by:
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
RENOVATE SURGICAL SUITE
PHASE II
SALEM VA MEDICAL CENTER
Jon Manninen, COR
2025-12-30
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
ENGINEER OF RECORDCONSULTANTS
Civil Engineering:
LABELLA ASSOCIATES
Architecture:
PF&A DESIGN, P.C. Project Number 658-19-103
Fire & Life Safety:
STANTON ENGINEERING SERVICES, LLC
JJP EBP
PLAN
NORTH
ACTUAL
NORTH
0' 10' 20' 30'
SCALE 1" = 10'
12/30/2025
C-110
CIVIL
DEMOLITION &
EROSION CONTROL PLANS
LIMITS OF DISTURBANCE
LINETYPE/BLOCK DESCRIPTION
EROSION CONTROL LEGEND
LOD
SF SF SILT FENCE
LOD
SF
INLET PROTECTIONIP
TEMPORARY CONSTRUCTION ENTRANCECE
TREE PROTECTION FENCETP
C-110
1 DEMOLITION PLAN
SCALE: 1" = 10'
C-110
2 EROSION CONTROL PLAN
SCALE: 1" = 10'
W W
E
E
E
E
E
E
E
E E
E
E E E E
E E
E
E E
E
E
E
E
E
T
T T
T T
T
T T
T T T
T T
T T
T T
T
T
SS
UG
UG
UG
UG
UG
UNDERGROUND UTILITIES,
BY OTHERS (TYP.)
SEE MECHANICAL PIPING PLAN
P1-MP102
TWO 8,000 GAL UNDERGROUND
FUEL STORAGE TANKS
(DIRECT BURIED)
BTM. OF TANK ELEV. = 1082' (MIN.)
(SEE SHEET C-501)
UNDERGROUND UTILITIES,
BY OTHERS (TYP.)
MH
MH
MH
MH
MANHOLE ACCESS
(TYP.)
NEW SIDEWALK TO MATCH
EXISTING SECTIONAL THICKNESS.
MATCH TO EXISTING GRADES.
(SEE SHEET C-501)
NEW ASPHALT TO MATCH
EXISTING SECTIONAL THICKNESS.
MATCH TO EXISTING GRADES.
(SEE SHEET C-501)
NEW CG-6 CURB
(SEE SHEET C-501)
REPLACE BENCH & TRASH CAN
AT OWNER'S DISCRETION AFTER
CONSTRUCTION IS COMPLETED
PROP. 4" WATER (DIP)
4'-3"
0+00
8" X 4" TAPPING
SLEEVE & VALVE
(SEE SHEETS C500 - C501)
0+81
4" 1/8 HB
1+16
4" 1/4 HB
1+05
4" CAP
3'-0"
REACTION BLOCKING TO
BE PROVIDED AT ALL BENDS.
(SEE SHEET C-500, TYP.)
CONTRACTOR SHALL CORE CONCRETE
TUNNEL FOR WATERLINE INSTALLATION
AND PROVIDE SEALS AND NON-SHRINK
GROUT TO MAKE WATER-TIGHT
TYPE D VALVE BOX
SEE FIRE PROTECTION
DRAWINGS FOR CONTINUATION
1+03
4" 1/8 HB
0+50
1+00
0+00
.81
.24
.76
.8'
.2'
.8' ' '
-0+50 0+00 0+50 1+00 1+50 1+75
MAINTAIN MINIMUM
3.50' COVER
EX. ELEC LINE
CROSSINGS
(ELEVATION TO BE
VERIFIED BY CONTRACTOR) EX. TELECOM LINE
CROSSINGS
(ELEVATION TO BE
VERIFIED BY CONTRACTOR)
EX. TUNNEL
CROSSING
EX. 8" WATER
(ELEVATION TO
BE VERIFIED BY
CONTRACTOR)
EXISTING GRADE
PROP. 4" WATER (DIP)
4" VALVE & VALVE BOX
(SEE SHEETS C-500 & C-501)
X
0+00
8" X 4" TAPPING
SLEEVE & VALVE (SEE
SHEETS C500 - C501)
INV. = 1086.81'
X
0+81
4" 1/8 HB
INV. = 1087.11'
X
1+05
4" CAP
INV. = 1087.36'
45° HORIZ. BEND
REACTION BLOCKING
TO BE PROVIDED.
(SEE SHEET C-500, TYP.)
X
1+03
4" 1/8 HB
INV. = 1087.33'
NO. DESCRIPTION DATE
on e ei gh th in ch o ne fo ot th re e in ch es o ne fo ot 6"
6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot
6"
6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot 4 on e qu ar te r i nc h on e fo ot
VA FORM 08-6231
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
VA Drawing Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved by:
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
RENOVATE SURGICAL SUITE
PHASE II
SALEM VA MEDICAL CENTER
Jon Manninen, COR
2025-12-30
321 4 5 6 7 8 9 10
A
B
C
D
E
F
21 4 5 6 7 8 9 10
A
C
D
E
F
ENGINEER OF RECORDCONSULTANTS
Civil Engineering:
LABELLA ASSOCIATES
Architecture:
PF&A DESIGN, P.C. Project Number 658-19-103
Fire & Life Safety:
STANTON ENGINEERING SERVICES, LLC
JJP EBP
PLAN
NORTH
ACTUAL
NORTH
0' 10' 20' 30'
SCALE 1" = 10'
12/30/2025
C-200
CIVIL
SITE LAYOUT &
WATERLINE PROFILE
EXISTING
SUBJECT PROPERTY LINE
PROPOSED DESCRIPTION
LEGEND
ADJACENT PROPERTY LINE
MAJOR CONTOUR
MINOR CONTOUR
BUILDING
CONCRETE PAVEMENT
WALKWAY
ASPHALT PAVEMENT
CURB
FENCE
SANITARY MANHOLE
WATERLINE
GAS LINE
U/G ELECTRIC LINE
U/G COMMUNICATIONS LINE
U/G SEWER LINE
U/G STORM LINE
U/G UTILITY LINE, BY OTHERSUG
CLEANOUT/VENT
DRAINAGE MANHOLE
CATCH BASIN
ELECTRIC MANHOLE
ELECTRIC TRANSFORMER
LIGHT POLE
AIR CONDITION COMPRESSOR
HYDRANT
WATER VALVE
TELEPHONE MANHOLE
HEAT PUMP
MH TANK ACCESS MANHOLE
FIRE DEPARTMENT CONNECTION
WATER LINE CAP
SITE PLAN NOTES:
1. CONTRACTOR SHALL TEST PIT FOR EXISTING UTILITIES PRIOR TO CONSTRUCTION.
2. SEE SHEETS C-500 - C-501 FOR SITE DETAILS.
WATERLINE, BY OTHERS
C-200
1 SITE LAYOUT PLAN
SCALE: 1" = 10'
C-200
2 WATERLINE PROFILE
SCALE: H: 1" = 20'
V: 1" = 2'
UTILITY NOTES
1. ALL EXCAVATED MATERIAL IS TO BE PLACED ON THE UPHILL SIDE OF TRENCH.
2. ALL STORM AND SANITARY SEWER LINES NOT IN STREETS ARE TO BE MULCHED AND SEEDED WITHIN 7 DAYS AFTER BACKFILL. NO MORE THAN
500 FT OF TRENCH IS TO BE OPEN AT ONE TIME.
3. CONSTRUCTION ACCESS ROADS SHALL BE LOCATED ON THE UPHILL SIDE OF THE TRENCH OR OVER THE TRENCH WHENEVER POSSIBLE.
4. MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE COMPACTED PER CORRESPONDING UTILITY DETAILS IN ORDER TO MINIMIZE EROSION
AND PROMOTE STABILIZATION.
5. ALL WORK MUST BE IN COMPLIANCE WITH APPLICABLE SAFETY REGULATIONS.
6. ALL STREAM CROSSINGS AND STREAM DIVERSION REQUIRE APPROVAL FROM THE ENVIRONMENTAL ENGINEER PRIOR TO ANY INSTREAM
WORK (SEE STREAM CROSSINGS / DIVERSIONS / WORK IN STREAMS).
TEMPORARY SEEDING NOTES
1. FERTILIZER: SHALL BE APPLIED AS 600 LBS./ACRE OF 10-20-10 (14 LBS./1,000 SQ. FT.) OR EQUIVALENT NUTRIENTS. LIME AND
FERTILIZER SHALL BE INCORPORATED INTO THE TOP 2 TO 4 INCHES OF THE SOIL IS POSSIBLE.
2. SURFACE ROUGHENING: IF THE AREA HAS BEEN RECENTLY LOOSENED OR DISTURBED, NO FURTHER ROUGHENING IS REQUIRED. WHEN THE AREA IS COMPACTED, CRUSTED, OR HARDENED, THE SOIL SURFACE SHALL BE LOOSENED BY DISCING, RAKING, HARROWING, OR
OTHER ACCEPTABLE MEANS (SEE SURFACE ROUGHENING, STD. & SPEC. 3.29).
3. TRACKING: TRACKING WITH BULLDOZER CLEATS IS MOST EFFECTIVE ON SANDY SOILS. THIS PRACTICE OFTEN CAUSES UNDUE COMPACTION OF THE SOIL SURFACE, ESPECIALLY IN CLAYEY SOILS, AND DOES NOT AID PLANT GROWTH AS EFFECTIVELY AS OTHER
METHODS OF SURFACE ROUGHENING.
4. SEEDING: SEED SHALL BE EVENLY APPLIED WITH A BORADCAST SEEDER, DRILL, CULTIPACKER SEEDER, OR HYDROSEEDER. SMALL GRAINS SHALL BE PLANTED NO MORE THAN 1.5 INCHES DEEP. SMALL SEEDS, SUCH AS KENTUCKY BLUEGRASS, SHOULD BE PLANTED NO MORE THAN 0.24 INCH DEEP. OTHER GRASSED AND LEGUMES SHOULD BE PLANTED FROM 0.25 TO 0.5 INCHES DEEP.
5. MULCHING:
5.1. SEEDINGS MADE IN FALL FOR WINTER COVER AND DURING HOT AND DRY SUMMER MONTHS SHALL BE MULCHED ACCORDING
TO MULCHING, STD & SPEC 3.35, EXCEPT THAT HYDROMULCHES (FIBBER MULCH) WILL NOT BE CONSIDERED ADEQUATE.
STRAW MULCH SHOULD BE USED DURING THESE PERIODS.
5.2. TEMPORARY SEEDINGS MADE UNDER FAVORABLE SOIL AND SITE CONDITIONS DURING OPTIMUM SPRING AND FALL SEEDING
DATES MAY NOT REQUIRE MULCH.
6. RE-SEEDING: AREAS WHICH FAIL TO ESTABLISH VEGETATIVE COVER ADEQUATE TO PREVENT RILL EROSION WILL BE RE-SEEDED AS
SOON AS SUCH AREA ARE IDENTIFIED.
REFER TO SHEET C-402 FOR ADDITIONAL TEMPORARY SEEDING NOTES AND SPECIFICATIONS.
RESTORATION NOTES
1. A SOILS ANALYSIS SHALL BE COMPLETED PRIOR TO APPLYING ANY FERTILIZER OR SOIL AMENDMENT TO ENSURE THE PROPER MIX IS USED.
2. SLOW-RELEASE FERTILIZER: GRANULAR OR PELLETED FERTILIZER CONSISTING OF 50 PERCENT WATER- INSOLUBLE NITROGEN, PHOSPORUS, AND
POTASSIUM IN THE FOLLOWING COMPOSITION.
COMPOSITION: 10 PERCENT NITROGEN, 6 PERCENT PHOSPHOROUS, 4 PERCENT POTASSIUM, BY WEIGHT.
3. CYANAMID COMPOUNDS AND HYDRATED LIME ARE NOT PERMITTED IN FERTILIZER MIXTURES.
4. FERTILIZER IS NOT REQUIRED FOR TEMPORARY SEED.
5. STRAW MULCH: CLEAN, MILDEW- AND SEED FREE OAT OR WHEAT STRAW WELL SEASONED BEFORE BALING, FREE FROM MATURE SEED BEARING STALKS
OR ROOTS OF PROHIBITED OR NOXIOUS WEEDS.
6. HYDRO FIBER MULCH: SHALL BE A WOOD FIBER OR WOOD FIBER AND CELLULOSE MIXTURE, PROVIDING THE CELLULOSE CONTENT DOES NOT EXCEED 20% BY VOLUME AND IS THOROUGHLY MIXED WITH WOOD FIBER MULCH. APPLY LIQUID TACKIFIER UNIFORMLY AT THE RATE OF 60 GALLONS PER ACRE, TO
KEEP STRAW MULCH IN PLACE.
7. PERMANENT SEED SPECIES: REFER TO "PERMANENT SEEDING NOTES" BELOW.
8. SLOPE STABILIZATION MESH STABILIZATION FABRIC SHALL BE ADDED ON ALL SLOPES EXCEEDING ONE FOOT VERTICAL TO THREE FEET HORIZONTAL (1:3).
9. ALL DISTURBED SOILS LOCATED IN LAWN AREAS ARE TO BE TILLED A MINIMUM OF 12" IN ORDER TO RESTORE THE ORIGINAL PROPERTIES OF THE SOIL.
10. FERTILIZER OR LIME ARE NOT TYPICALLY USED FOR TEMPORARY SEEDING, BUT IF USED SHOULD BE IN ACCORDANCE WITH THE PERMANENT SEEDING
NOTES ON THE LANDSCAPE PLAN.
11. ANY SEEDING METHOD MAY BE USED THAT WILL PROVIDE UNIFORM APPLICATION OF SEED TO THE AREA AND RESULT IN RELATIVELY GOOD SOIL TO SEED
CONTACT.
12. MULCH THE AREA WITH HAY OR STRAW AT 2 TONS PER ACRE (4 TONS PER ACRE IN WINTER). QUALIFY OF HAY OR STRAW MULCH ALLOWABLE WILL BE DETERMINED BASED ON LONG TERM USE AND VISUAL CONCERNS. MULCH ANCHORING WILL BE REQUIRED WHERE WIND OR AREAS OF CONCENTRATED
WATER ARE OF CONCERN.
13. TEMPORARY SEEDING SERVES AS MEANS TO REDUCE EROSION AND SEDIMENTATION BY STABILIZING DISTURBED AREAS THAT WILL NOT BE BROUGHT TO
FINAL GRADE FOR A PERIOD OF MORE THAN 30 DAYS.
14. TEMPORARY SEEDING REDUCES DAMAGE FROM SEDIMENT AND RUNOFF TO DOWNSTREAM OR OFF-SITE AREAS AND PROVIDES PROTECTION TO BARE SOILS EXPOSED DURING CONSTRUCTION UNTIL PERMANENT VEGETATION OR OTHER EROSION CONTROL MEASURES CAN BE ESTABLISHED.
15. SPECIFICATIONS: PRIOR TO SEEDING, INSTALL NECESSARY EROSION CONTROL PRACTICES SUCH AS DIKES, WATERWAYS, AND BASINS.
15.1. PLANT SELECTION: SELECT PLANTS APPROPRIATE TO THE SEASON AND SITE CONDITIONS FROM TABLES 3.31-B AND 3.31-C. NOTE THAT TABLE 3.31-B PRESENTS PLANTS WHICH CAN BE USED WITHOUT EXTENSIVE EVALUATION OF SITE CONDITIONS; TABLE 3.31-C PRESENTS MORE IN-DEPTH
INFORMATION ON THE PLANT MATERIALS.
15.2. SEEDBED PREPARATION: TO CONTROL EROSION ON BARE SOIL SURFACES, PLANTS MUST BE ABLE TO GERMINATE AND GROW. SEEDBED
PREPARATION IS ESSENTIAL.
15.2.1. LIMING: AN EVALUATION SHOULD BE CONDUCTED TO DETERMINE IF LIME IS NECESSARY FOR TEMPORARY SEEDING. IN MOST SOILS, IT TAKE UP TO 6 MONTHS FOR A PH ADJUSTMENT TO OCCUR FOLLOWING THE APPLICATION OF LIME. THEREFORE, IT MAY BE DIFFICULT TO JUSTIFY THE COST OF LIMING A TEMPORARY SITE, ESPECIALLY WHEN SOIL WILL LATER BE MOVED AND RE-GRADED. THE FOLLOWING TABLE MAY BE USED
TO DETERMINE THE ACTUAL NEED ALONG WITH SUGGESTED APPLICATION RATES.
PERMANENT SEEDING NOTES
1. PERMANENT SEEDING SERVES AS MEANS TO DO THE FOLLOWING:
1.1. TO REDUCE EROSION AND DECREASE SEDIMENT YIELD FROM DISTURBED AREAS.
1.2. TO PERMANENTLY STABILIZE DISTURBED AREAS IN A MANNER THAT IS ECONOMICAL, ADAPTABLE TO SITE CONDITIONS, AND
ALLOWS SELECTION OF THE MOST APPROPRIATE PLANT MATERIALS.
1.3. TO IMPROVE WILDLIFE HABITAT.
1.4. TO ENHANCE NATURAL BEAUTY.
1.5. SEE SEEDING SCHEDULES ON SHEET C-402.
REFER TO SHEET C-402 FOR ADDITIONAL PERMANENT SEEDING NOTES AND SPECIFICATIONS.
EROSION & SEDIMENT CONTROL MINIMUM STANDARDS
MS-1 PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN DORMANT FOR LONGER THAN 14 DAYS. PERMANENT STABILIZATION SHALL BE APPLIED TO AREAS THAT ARE TO
BE LEFT DORMANT FOR MORE THAN ONE YEAR.
TEMPORARY AND PERMANENT SEEDING ARE REQUIRED FOR THIS PROJECT AND ARE SHOWN ON THE PLANS.
MS-2 DURING CONSTRUCTION OF THE PROJECT, SOIL STOCK PILES AND BORROW AREAS SHALL BE STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION OF ALL SOIL STOCKPILES ON SITE AS WELL AS BORROW AREAS
AND SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE.
STABILIZE WITH TEMPORARY SEEDING & ENCLOSE BORROW OR STOCKPILE AREAS WITH SILT FENCE.
MS-3 A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON DENUDED AREAS NOT OTHERWISE PERMANENTLY STABILIZED. PERMANENT VEGETATION SHALL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT IS UNIFORM, MATURE ENOUGH TO SURVIVE AND WILL INHIBIT EROSION.
ADEQUATE SYMBOLS, DETAILS, AND NOTES ARE PROVIDED ON THE PLAN FOR DIRECTION.
MS-4 SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND-DISTURBING ACTIVITY AND SHALL BE
MADE FUNCTIONAL BEFORE UP-SLOPE LAND DISTURBANCE TAKES PLACE.
PERIMETER SILT FENCE AND 2 SEDIMENT TRAPS ARE SHOWN ON THE PLAN AND SHALL BE INSTALLED PRIOR TO
ANY ADDITIONAL GRADING.
MS-5 STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES AND
DIVERSIONS IMMEDIATELY AFTER INSTALLATION.
APPLY SEEDING TO DAM SECTION IMMEDIATELY AFTER CONSTRUCTION.
MS-6 SEDIMENT TRAPS AND SEDIMENT BASINS SHALL BE DESIGNED AND CONSTRUCTED BASED UPON THE TOTAL DRAINAGE AREA TO BE SERVED BY THE TRAP OR BASIN. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT TRAP SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA AND THE TRAP SHALL ONLY CONTROL DRAINAGE AREAS LESS THAN THREE ACRES. SURFACE RUNOFF FROM DISTURBED AREAS THAT IS COMPRISED OF FLOW FROM DRAINAGE AREAS GREATER THAN OR EQUAL TO THREE ACRES SHALL BE CONTROLLED BY A SEDIMENT BASIN. THE MINIMUM STORAGE CAPACITY OF A SEDIMENT BASIN SHALL BE 134 CUBIC YARDS PER ACRE OF DRAINAGE AREA. THE OUTFALL SYSTEM SHALL, AT A MINIMUM, MAINTAIN THE STRUCTURAL INTEGRITY OF THE BASIN DURING A 25-YEAR STORM OF 24-HOUR DURATION. RUNOFF COEFFICIENTS USED IN RUNOFF CALCULATIONS SHALL CORRESPOND TO A BARE EARTH CONDITION OR THOSE CONDITIONS EXPECTED TO EXIST
WHILE THE SEDIMENT BASIN IS UTILIZED.
INSTALL SEDIMENT TRAPS PRIOR TO ANY ADDITIONAL GRUBBING OR LAND DISTURBANCE.
MS-7 CUT- AND FILL-SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION.
SLOPES THAT ARE FOUND TO BE ERODING EXCESSIVELY WITHIN ONE-YEAR OF PERMANENT STABILIZATION SHALL BE PROVIDED WITH ADDITIONAL SLOPE STABILIZING MEASURES UNTIL THE PROBLEM IS CORRECTED.
SLOPE STABILIZING MEASURES ARE DETAILED FOR USE THE PLANS, SPECIFICALLY BLANKET MATTING SHALL
BE APPLIED TO ALL SLOPES 2:1 OR STEEPER.
MS-8 CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT- OR FILL-SLOPES UNLESS CONTAINED WITHIN AN
ADEQUATE TEMPORARY OR PERMANENT CHANNEL, FLUME OR SLOPE DRAIN STRUCTURE.
ALL CONCENTRATED RUNOFF FROM THIS RE-DEVELOPMENT AREA SHALL BE DIRECTED IN THE PROPOSED STORM WATER MANAGEMENT FACILITIES AND CONVEYED INTO THE EXISTING BMP, AS IF A NATURAL CHANNEL;
THE EXISTING CONTROLLING RELEASE STRUCTURE, RISER AND DETENTION SYSTEM LOCATED AT THE EXISTING
SITE OUTFALL IS TO REMAIN UNCHANGED.
MS-9 WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION SHALL BE
PROVIDED.
SHOULD THIS BECOME EVIDENT ONSITE, CONTRACTOR SHALL INSTALL RIP-RAP APRON TO CONVEY SEEPAGE
DOWNGRADE TO THE EXISTING ROADWAY.
MS-10 ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT-LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR
OTHERWISE TREATED TO REMOVE SEDIMENT.
INLET & CULVERT INLET PROTECTION IS SHOWN ON THE PLANS FOR EXISTING INLETS AND SHALL BE ADDED TO EACH NEW INLET AS IT IS CONSTRUCTED. INLET & CULVERT PROTECTIONS SHALL BE ADDED TO ALL EXISTING
INLETS & CULVERTS WITHIN THE PHASE 1 LOW DURING ESC PHASE 1 OPERATIONS.
MS-11 BEFORE NEWLY CONSTRUCTED STORMWATER CONVEYANCE CHANNELS OR PIPES ARE MADE OPERATIONAL, ADEQUATE OUTLET PROTECTION AND ANY REQUIRED TEMPORARY OR PERMANENT CHANNEL LINING SHALL BE
INSTALLED IN BOTH THE CONVEYANCE CHANNEL AND RECEIVING CHANNEL.
THERE IS ONE PROPOSED STORMWATER CONVEYANCE CHANNEL TO ROUTE WATER THROUGH THE CURB CUT
AND INTO RR POND #1. REFER TO ESC PHASE 3 (SHEET C404).
MS-12 WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED, PRECAUTIONS SHALL BE TAKEN TO MINIMIZE ENCROACHMENT, CONTROL SEDIMENT TRANSPORT AND STABILIZE THE WORK AREA TO THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION. NON-ERODIBLE MATERIAL SHALL BE USED FOR THE CONSTRUCTION OF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE USED FOR THESE STRUCTURES IF ARMORED BY
NON-ERODIBLE COVER MATERIALS.
NOT APPLICABLE.
MS-13 WHEN A LIVE WATERCOURSE MUST BE CROSSED BY CONSTRUCTION VEHICLES MORE THAN TWICE IN ANY SIX-MONTH PERIOD, A TEMPORARY VEHICULAR STREAM CROSSING CONSTRUCTED OF NON-ERODIBLE MATERIAL
SHALL BE PROVIDED.
NOT APPLICABLE.
MS-14 ALL APPLICABLE FEDERAL, STATE AND LOCAL REQUIREMENTS PERTAINING TO WORKING IN OR CROSSING LIVE
WATERCOURSES SHALL BE MET.
NOT APPLICABLE.
MS-15 THE BED AND BANKS OF A WATERCOURSE SHALL BE STABILIZED IMMEDIATELY AFTER WORK IN THE
WATERCOURSE IS COMPLETED.
NOT APPLICABLE.
MS-16 UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN
ADDITION TO OTHER APPLICABLE CRITERIA:
a. NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME.
b. EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES.
c. EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED
SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY
AFFECT FLOWING STREAMS OR OFF-SITE PROPERTY.
d. MATERIAL USED FOR BACKFILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE
EROSION AND PROMOTE STABILIZATION.
e. RESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THIS CHAPTER.
f. APPLICABLE SAFETY REQUIREMENTS SHALL BE COMPLIED WITH.
THIS APPLIES TO THE ALL PRIVATE UTILITIES, SANITARY SEWER, WATERLINE OR STORM SEWER PIPE
INSTALLATIONS.
MS-17 WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED OR PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE TRANSPORT OF SEDIMENT BY VEHICULAR TRACKING ONTO THE PAVED SURFACE.
WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION SHALL APPLY TO
INDIVIDUAL DEVELOPMENT LOTS AS WELL AS TO LARGER LAND-DISTURBING ACTIVITIES.
THE TWO CONSTRUCTION ENTRANCES ARE LOCATED INTERNALLY WITHIN THE LOD AND DO NOT DIRECTLY INTERSECT WITH THE PUBLIC ROAD (OLD STAGE ROAD). CONTRACTOR SHALL KEEP THE ROADS FREE FROM
SEDIMENT, DEBRIS AND MUD AT ALL TIMES DURING CONSTRUCTION.
MS-18 ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30-DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, UNLESS OTHERWISE AUTHORIZED BY THE VA ESCP AUTHORITY. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO
PREVENT FURTHER EROSION AND SEDIMENTATION.
CONTRACTOR SHALL FOLLOW MS-18 ONCE FINAL GRADES ARE MET AND OBTAIN APPROVAL FROM
ENVIRONMENTAL INSPECTOR.
MS-19 PROPERTIES AND WATERWAYS DOWNSTREAM FROM DEVELOPMENT SITES SHALL BE PROTECTED FROM SEDIMENT DEPOSITION, EROSION AND DAMAGE DUE TO INCREASES IN VOLUME, VELOCITY AND PEAK FLOW RATE OF STORMWATER RUNOFF FOR THE STATED FREQUENCY STORM OF 24-HOUR DURATION IN ACCORDANCE WITH THE FOLLOWING STANDARDS AND CRITERIA. STREAM RESTORATION AND RELOCATION PROJECTS THAT INCORPORATE NATURAL CHANNEL DESIGN CONCEPTS ARE NOT MAN-MADE CHANNELS AND SHALL BE EXEMPT FROM ANY FLOW RATE CAPACITY AND VELOCITY REQUIREMENTS FOR NATURAL OR MAN-MADE CHANNELS:
a. CONCENTRATED STORMWATER RUNOFF LEAVING A DEVELOPMENT SITE SHALL BE DISCHARGED DIRECTLY INTO AN ADEQUATE NATURAL OR MAN-MADE RECEIVING CHANNEL, PIPE OR STORM SEWER SYSTEM. FOR THOSE SITES WHERE RUNOFF IS DISCHARGED INTO A PIPE OR PIPE SYSTEM, DOWNSTREAM STABILITY
ANALYSES AT THE OUTFALL OF THE PIPE OR PIPE SYSTEM SHALL BE PERFORMED.
b. ADEQUACY OF ALL CHANNELS AND PIPES SHALL BE VERIFIED IN THE FOLLOWING MANNER:
(1) THE APPLICANT SHALL DEMONSTRATE THAT THE TOTAL DRAINAGE AREA TO THE POINT OF ANALYSIS
WITHIN THE CHANNEL IS ONE HUNDRED TIMES GREATER THAN THE CONTRIBUTING DRAINAGE AREA OF
THE PROJECT IN QUESTION; OR
(2)(a) NATURAL CHANNELS SHALL BE ANALYZED BY THE USE OF A TWO-YEAR STORM TO VERIFY THAT
STORMWATER WILL NOT OVERTOP CHANNEL BANKS NOR CAUSE EROSION OF CHANNEL BED OR
BANKS.
(2)(b) ALL PREVIOUSLY CONSTRUCTED MAN-MADE CHANNELS SHALL BE ANALYZED BY THE USE OF A 10-YEAR STORM TO VERIFY THAT STORMWATER WILL NOT OVERTOP ITS BANKS AND BY THE USE OF A TWO-YEAR STORM TO DEMONSTRATE THAT STORMWATER WILL NOT CAUSE EROSION OF CHANNEL
BED OR BANKS; AND
(2)(c) PIPES AND STORM SEWER SYSTEMS SHALL BE ANALYZED BY THE USE OF A 10-YEAR STORM TO
VERIFY THAT STORMWATER WILL BE CONTAINED WITHIN THE PIPE OR SYSTEM.
(2)(d) IF EXISTING NATURAL RECEIVING CHANNELS OR PREVIOUSLY CONSTRUCTED MAN-MADE CHANNELS
OR PIPES ARE NOT ADEQUATE, THE APPLICANT SHALL:
(3) IMPROVE THE CHANNELS TO A CONDITION WHERE A 10-YEAR STORM WILL NOT OVERTOP THE BANKS AND A TWO-YEAR STORM WILL NOT CAUSE EROSION TO THE CHANNEL, THE BED, OR THE BANKS; OR
(4) IMPROVE THE PIPE OR PIPE SYSTEM TO A CONDITION WHERE THE 10-YEAR STORM IS CONTAINED
WITHIN THE APPURTENANCES;
(5) DEVELOP A SITE DESIGN THAT WILL NOT CAUSE THE PRE-DEVELOPMENT PEAK RUNOFF RATE FROM A TWO-YEAR STORM TO INCREASE WHEN RUNOFF OUTFALLS INTO A NATURAL CHANNEL OR WILL NOT
CAUSE THE PRE-DEVELOPMENT PEAK RUNOFF RATE FROM A 10-YEAR STORM TO INCREASE WHEN
RUNOFF OUTFALLS INTO A MAN-MADE CHANNEL; OR
(6) PROVIDE A COMBINATION OF CHANNEL IMPROVEMENT, STORMWATER DETENTION OR OTHER
MEASURES WHICH IS SATISFACTORY TO THE VESCP AUTHORITY TO PREVENT DOWNSTREAM EROSION.
c. THE APPLICANT SHALL PROVIDE EVIDENCE OF PERMISSION TO MAKE THE IMPROVEMENTS.
d. ALL HYDROLOGIC ANALYSES SHALL BE BASED ON THE EXISTING WATERSHED CHARACTERISTICS AND THE
ULTIMATE DEVELOPMENT CONDITION OF THE SUBJECT PROJECT.
e. IF THE APPLICANT CHOOSES AN OPTION THAT INCLUDES STORMWATER DETENTION, HE SHALL OBTAIN
APPROVAL FROM THE VESCP OF A PLAN FOR MAINTENANCE OF THE DETENTION FACILITIES. THE PLAN SHALL SET FORTH THE MAINTENANCE REQUIREMENTS OF THE FACILITY AND THE PERSON RESPONSIBLE
FOR PERFORMING THE MAINTENANCE.
f. OUTFALL FROM A DETENTION FACILITY SHALL BE DISCHARGED TO A RECEIVING CHANNEL, AND ENERGY DISSIPATORS SHALL BE PLACED AT THE OUTFALL OF ALL DETENTION FACILITIES AS NECESSARY TO
PROVIDE A STABILIZED TRANSITION FROM THE FACILITY TO THE RECEIVING CHANNEL.
g. ALL ON-SITE CHANNELS MUST BE VERIFIED TO BE ADEQUATE.
h. INCREASED…