Attachment 8 - ICRA.pdf

PDF 2 MB Posted

Attached to
Z2DA--Replace Dual Duct Boxes on Second Floor - 539-21-201 Federal contract opportunity
Solicitation number
36C25026B0042
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

This is a Construction Health and Safety Form (Attachment #1) for a federal healthcare facility construction project titled "Replace Dual Duct Boxes on 2nd Floor" (Project Number 539-21-201). The project is classified as a Contracted Project with Kevin Henderson designated as the VAMC Competent Person. The scope involves correcting mixing boxes on the second floor and replacing ineffective hot and cold deck mixing boxes with fan coil or terminal units to improve ventilation and temperature control for patient care areas.

The project has been assigned an Infection Control Risk Assessment (ICRA) Class III classification based on the Risk Assessment Matrix for IC Guidelines for Construction. The project is categorized as Type C construction activity (moderate to high level of dust generation), requiring comprehensive infection control precautions during and after construction. Class III requirements include sealing holes, pipes, and conduits; constructing anteroom barriers with HEPA vacuum access; mandatory shoe covers for personnel; and prohibition of barrier removal until project completion and inspection by Safety, Infection Control, and Environmental Services Departments. Upon completion, work surfaces must be wiped with disinfectant, wet mopped, and HVAC systems isolated. The form confirms TB Risk Determination as NO, indicating tuberculosis testing is not required for contractors. Interim Life Safety Measures are specified at Level II, requiring temporary construction partitions be smoke-tight and non-combustible. The form documents signatures from the Project COR (Kevin D. Henderson), Safety Manager (Thomas C. Elder), Infection Control representative, and Construction Health & Safety Team Chair, with dates ranging from October 2020 to February 2021. Additional requirements include 14-day notice for utility shutdowns, contractor badge requirements, OSHA 10-hour or 30-hour construction worker certification, and evaluation of contractor safety records prior to contract award.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--Replace Dual Duct Boxes on Second Floor - 539-21-201, newest first.
File Type Posted
Atch RFI 4 Lead Paint Report.pdf PDF
Atch RFI 6 life safety plan.pdf PDF
Atch RFI 7 ACM SURVEY REPORT.pdf PDF
36C25026B0042 0002.docx DOCX document
36C25026B0042_1.pdf PDF
36C25026B0042 0001.docx DOCX document
Attachment 12 - Tridium Niagara Redacted.pdf PDF
Attachment 1 - OH20260082 01022026.pdf PDF
Attachment 4 - Drawings.pdf PDF
Attachment 3 - Specs.pdf PDF
Attachment 2 - VHA Directive 1192.01.pdf PDF
Attachment 11 -Honeywell Siemens JCI Redacted.pdf PDF
Attachment 10 - FX Controls Redacted.pdf PDF
Attachment 9 - PCRA.pdf PDF
Attachment 6 - EMR Form.docx DOCX document
Attachment 5 - VAAR 852.219-75.docx DOCX document
Attachment 7 - Request for Information.docx DOCX document
36C25026B0042_1.docx DOCX document
Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .