Attachment 8__0123025 - Northport SPS - E Add 1.pdf

PDF 666 KB Posted

Attached to
Y1DA--630-12-106 Renovate Sterile Processing Dept. - Building 200
Solicitation number
36C24225B0039
Issued by

About this file

These electrical engineering documents are for a Renovate Sterile Processing Department project at the Northport VA Medical Center. The drawings detail electrical system modifications, including installing a new 750kVA, 480V, 3-phase transformer, mobile power distribution unit, and reconfiguring existing electrical infrastructure. The electrical plans cover ground floor temporary power arrangements, riser diagrams, lighting control matrices, equipment schedules, and branch panel configurations. Key electrical components include new transformers, disconnect switches, emergency power systems, and lighting fixtures from manufacturers like Cooper Lighting, Lithonia, and Metalux. The project involves upgrading electrical systems to support renovations in the sterile processing area, with careful integration of new and existing electrical infrastructure.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C1-6000

ONCOLOGY

1,707.22

B1-2000

PHARMACY

4,587.74

C1-5000

VOLUNTEERS

851.45

C1-4000

SURGICAL

1,573.88

C1-3000

ON CALL

2,206.34

C1-5500

IRM OFFICE

1,483.38

C1-3500

EMERGENCY

1,403.42

C1-3100

EMP. HEALT

491.84

C1-1000

EMERGENCY

5,913.72

C1-1100

OUTREACHRM

208.85

B1-6000

ESCORT SER

503.04

C1-2700

PHYSICAL T

337.88

B1-6250 M.A.S.

4,686.71

A1-1600

CARDIOLOGY

5,893.24

A1-1800 A.S.U.

1,624.33

A1-8600

RADIOLOGY

11,546.47

A1-6600

SURGERY OR

16,146.55

B1-2900

MECHANICAL

1,229.79

A1-1200

PULMONARY

2,203.66

A1-5000 I.R.M.

1,660.82

A1-4000

GASTROENTR

1,520.56

B1-3600

D.A.V. OFF

1,619.83

A1-1260 I.C.U.

7,206.80

D1-1000

PRIMARY CA

35,381.22

C

12 10.811

D

E

F

E

F

11 10.8

10 9 8 6

10 9

24 33.2

D

E

24 33.2

F

G

B

A

G

H1

J

K

10.811 10 9 8

12 11 10

H

H.1

7 6 5 1

D

G

H

J

K

5 4

3.2 3

H1

E

J.4

13 12 11 10 9 8

5 4 3 2 1

S

R

Q

P

N

M

L L

M

N

P

Q

R

S

Q83

3.2

4 3.2

F

E

1 20.2

21 21.9 22

21.9 22 23 23.2 2424

23 23.2 24 25

13 12 11 10 9 8 7 6

HISTOLOGY LAB AREA

C

B

CURTAIN TRACK

#7

#6

#5

#4

C1-78

LAB STORAGE

496.12

C1-760

CHIEF PATHOLOGY

255.00

C1760

PATHOLOGY

142.89

C1-76L 129.64

C1-76K

BREAK ROOM

285.41

C1-76J

PATHOLOGIST/

106.76

C1-76H

SUPERVISOR/

126.09

C1-76G

LEAD TECHNOLOGIST OFFICE

131.77 C1-76F

LAB ADMINISTRATIVE

123.98

C1-76E

CONFERENCE ROOM

149.89

C1-66B

8.74

C1-65 31.13

C1-66A

BATHROOM

45.79

C1-64A

BATHROOM

45.12

C1-66

1 BEDROOM

126.40

C1-64

WOMEN'S RM

134.72

C1-62

137.16

C1-62A

10.14

C1-61B

10.14

C1-61A

BATHROOM

44.35

C1-61

O.D. RM.

135.15

C1-59

O.D. RM.

149.68

C1-58A

BATHROOM

44.35

C1-58

135.11

C1-57

119.50

C1-80

TOILET

88.86

C1-81

61.11

C1-83 63.13

C1-84

87.50

C1-C10B

FEC

2.70

C1-76A

SEC PATHOLOGY

146.55

C1-74 34.01

C1-C11A E.C.

45.50

C1-76B

COAGULATION

112.53

C1-76C

96.96

C1-76D

LOCKER

155.61

C1-68

CANCER REG

115.84

C1-67

ONCOLOGY

131.87

C1-75

CANCER REGISTRY

146.38

C1-73

PATIENT

120.44

C1-71

ATTEND

135.44

C1-69

CONFERENCE

291.38

C1-51

58.72

C1-C13

CORRIDOR

467.35

C1-49

COFFEE

83.64

C1-C13A

ELEC. CL.

12.73

C1-41

CLINICAL

149.78

C1-42

CHF. SURGICAL

206.05

C1-39

MEN TOILET

67.14

C1-38

DOD ADMIN.

117.50

C1-37

121.92

C1-36

ER. CODING

152.42

C1-35

SOCIALWORK

122.08

C1-28

NURSE OD.

151.57

C1-C6A E.C.

79.65

C1-29

PHYSICIAN ASST.

170.51

C1-31

VA/DOD

148.08

C1-C1B

ST. 2

141.60

C1-C1A

FEC

3.13

C1-26A

EXAM/TREAT

165.87

C1-26B

EXAM/TREAT

128.88

C1-27C

EXAM/TREAT

103.42

150.84

C1-26

EXAM/TREAT

131.82

C1-56A

BATHROOM

46.97

C1-33A

BATHROOM

46.98

C1-56

146.86

C1-34

139.55

C1-59A

10.14

C1-58B

10.14

C1-57A

CL.

10.08

C1-56B

CL.

10.08

C1-33 129.67

C1-32

25.73

C1-17A

BATHROOM

39.69

C1-17

ER ON CALL

134.24 C1-C3

VEST.

83.07

D.W.

AMBULANCE

1,192.28

C1-15

SURGICAL ER

271.12 C1-15A

35.39

C1-16

26.78

C1-C4

CORR.

408.82

C1-C1C 12.32

C1-C1D 12.32

C1-22

OBSERVATION

239.06

C1-7

140.03

C1-20

EXAM/TREAT

120.21 C-14 H.A.C.

43.71

C1-11

FILE RM.

45.48

C1-C3A

FEC

5.25

C1-C11

CORRIDOR

598.12

C1-C12

CORRIDOR

482.56

C1-34A

CL.

10.08

C1-33B

CL.

10.08

C1-C5

CORRIDOR

184.18

C1-C7

649.05

C1-76

LABORATORY

2,572.03

C1-77A

TCOMM. CL.

12.75

C1-77B

ELEC. CL.

13.81 C1-C10

CORR.

226.32

B1-9A

CHF. CARDI

154.17

B1-17A

VEST.

12.25

B1-29

CLIMATE CO

856.96

59.50

80.75

B1-9B

NURSE

123.00

B1-C3A E.C.

16.50

B1-18

PHARMACY

148.44

B1-10

126.00

B1-16

CHF PHARMA

155.64

102.00

B1-9

121.50

B1 224

LOUNGE

120.75

B1-19 125.00

C1-6

EXAM

135.56

C1-8

EMERG.

141.91

C1-5

WOMEN'S TOIL

41.00

C1-4

MEN'S TOILET

39.96

C1-C1

CORRIDOR

382.10

E1-15

FEMALE H/C TOILET

59.23

E1-C10A

MED.RECORDS

75.32

E1-16

MEN'S H/C TOILET

114.98

E1-14 H.A.C.

80.05

E1-17

CENTRAL

305.51

E1-C12A

FEC

1.46

E1-C1A

FEC

0.83

E1-C11

RECEPTIONIST

334.63

E1-58

EXAM/

86.48

E1-57

CLINIC.DIE

118.75

CI-2

C1-C3B

CORRIDOR

463.67

C1-15B

ER

74.92

C1-C11B

FIRE CL.

3.78

C1-45

SURGICAL

163.08

C1-46

OUTREACHRM

271.35

C1-53

OFFICE

79.08

C1-52

NURSE

96.37

C1-47

PHYSICIAN

68.90

C1-48

PHYSICIAN

71.42

C1-44

PHYSICIAN

55.17

C1-43

ASST.CHIEF

53.78

C1-C9

CORRIDOR

115.50

C1-70

CHIEF

171.05

C1-72

COMPREHENSIVE CANCER

402.36

C1-54

VESTIBULE

32.64

C1-40

WORK ROOM

144.58

C1-30

EMP. HEALT

176.12

C1-C6

CORRIDOR

368.08

C1-76M

CORE

133.20

C1-76N

FLOW CYTOM

108.52

E1-C10

WAITING RM

795.01

E1-C1

CORRIDOR

1,198.58

E1-18

SOILED UT.

102.51

E1-56

EXAM/TREAT

122.54

E1-55

PRIMARY CARE

109.82

E1-54

PRIMARY CARE

113.09

E1-53

EKG

108.84

E1-52

PRIMARY CARE

118.75

E1-69

EXAM/TREAT

98.46

E1-67

EXAM/TREAT

99.42

E1-65

EXAM/TREAT

99.42

E1-63

EXAM/TREAT

94.60

E1-61

EXAM/TREAT

115.22

E1-70

ELECTRICAL

44.58

E1-71

COMMUN.

32.39

E1-C19A

FEC

0.81

E1-44

EXAM/TREAT

100.45

E1-48

PRIMARY CARE

128.52

E1-50

PRIMARY CA

134.18

E1-51

EXAM/TREAT

117.76

E1-49

EXAM/TREAT

103.01

E1-60

EXAM/TREAT

104.06

E1-42

EXAM/TREAT

84.94

E1-C18

CORR.

236.07

E1-59

EXAM/TREAT

107.86

E1-45

PRIMARY CA

105.30

E1-43

PRIMARY CARE

127.97

E1-66

EXAM/TREAT

105.86

E1-46

PRIMARY CA

133.98

E1-47

EXAM/TREAT

102.24

E1-C20

CORR.

325.41

E1-C13A

FEC

0.86

E1-68

EXAM/TREAT

72.96

E1-19

CLEAN UTILITY

136.47

E1-20

EXAM/TREAT

102.10

E1-21B

FEMALE H/C TOILET

48.49

E1-72

CL.

39.29

E1-22

COMM.

34.17

E1-C18A

VALVE CABINET

0.58

E1-C19

CORRIDOR

357.32

E1C13

CORRIDOR

487.48

E1-C12

CORRIDOR

785.48

E1-37

PR I MA R Y C AR E

148.85

E1-32

SECURITY

244.77

E1-33

AMB CARE RN

106.58

E1-35

PR IMAR Y C AR E O FF IC E

129.35

E1-34

PRIMARY

143.36

E1-21A

M. H/CTOILET

46.78

E1-31

WHEELCHAIR

126.03

E1-28

CONFERENCE ROOM

352.45

E1-38

STAFF LOCKER

91.07

E1-26

STAFF LOCKER

88.26

E1-26A

TOILET

27.56

E1-38A

TOILET

27.56

E1-C17

CORR.

163.55

E1-C16

CORRIDOR

120.18

99.14

E1-C14A

FEC

1.11

E C

C O R R

ID

O R

.7

E1-25

ACHA NURSING

80.56

OUTPATIENT

CLINIC

107.94

E1-29

BLUE/YELLOW

109.82

E1-30

CHIEF

149.84

E1-C15

CORRIDOR

142.64

E1-C2

RECEPT/CON

62.67

E1-4

PHARMACY

106.17

E1-10

PHARM

100.58

E1-40

EXAM ROOM

114.33

E1-39

TOILET

47.83

E1-41 38.50

E1-13

51.46

E1-12

G.I. OFFICE

276.76

E1-11 106.25

E 1A

S T O R A G E

.0

E1-8

PHARM

146.67

E1-8A

DRESSING RM.

19.19

E1-9

DRESSING RM.

22.67

E1-9A

OFF/EXAM

19.83

E1-9B

DRESSING R

19.83

E1-7

TECH.OTHER

128.00

E1-C6

CORR.

128.17

D1-56

BREAK ROOM

672.77

D1-49

MANAGEMENT

SERVICE

D1-48

MANAGEMENT

115.15

D1-46

AMB CARE

109.00

D1-44

AMB CARE

SUPERVISOR

D C

C O R R

ID

O R

.2

D1-57

PHARMACY

148.61

D C

C O R R

ID

O R

.8

D1-53

FEMALE H/C TOILET

174.39

D1-54 H.A.C.

50.74

D1-55

M. H/CTOILET

181.46

D1-C22

CORRIDOR

190.54

D1-8

CONTROL SU

148.65

D1-7

PREPACK

108.00

D1-6 H.A.C.

54.05

D1-40 H.A.C.

69.26

D1-34

CLOSET

17.23

D1-38

ELECTRICAL

85.80

D1-33

88.00

F. H/C TOILET

66.11

D1-39

M. H/CTOIL

60.14

D1-41

120.59

D1-29

101.80

D1-31

100.00

D1-C19

CORRIDOR

66.52

D1-25

EXAM ROOM

107.40

D1-28

EXAM ROOM #3

121.50

D1-42

ORTHO EXAM

135.20

D1-27

EXAM ROOM #7

120.13

D1-43

126.69

D1-32

CAST ROOM

132.71CLINIC

RECORDS

57.76

D1-36

STORAGE

45.85

D1-12

MEDICAL

SERVICE

D1-21

EXAM ROOM #1

113.09D1-45 #5

114.40

D1-47 #4

123.74

D1-50

EXAM ROOM

123.74

D1-16

EXAM ROOM

126.28

D1-14

OFF. CHIEF/DAY TREAT #1

116.15 D1-23

EXAM ROOM #4

117.20

D1-24

EXAM ROOM #5

110.39

D1-26

EXAM ROOM #6

109.20

D1-22

CONFERENCE

301.64D1-20

M. H/CTOILET

54.90

D1-17

LOCKER ROOM

57.02

D1-15

SCREENING AREA

730.23

D1-13

STAFF

204.12

D1-15A

CLOSET

61.49

D1-C15

CORRIDOR

338.75

D1-C16

CORRIDOR

130.72

D1-C17A

VALVE CAB.

0.58

D1-C17

CORRIDOR

273.95

D1-C18

CORRIDOR

343.65

D1-C18A

FEC

1.67

D1-C15A

FEC

1.15

TELEPHONES

D1-5

F. H/CTOILET

64.29

D1-4

M. H/CTOILET

160.83

D1-C7

ELEV. LOBBY

279.88

P4

ELEV.

85.57

P5

ELEV.

86.42

D1-9B

DRUG RECEIVING

346.41

D1-51

ELEC. CL.

10.88

D1-52

COMM.

17.50

D

C O N S U L T

R M

.2

D A

P R E S C R

IP

T

IO

N

R E C V

.6

D1-9D

FEC

1.50

D1-9C

DISPENSING

165.41 D1-9

ACTIVE STO

920.66

D1-9A

ASSEMBLE

851.41

D1-C1

VESTIBULE

855.24

D1-11

M. H/CTOILET

219.22

D1-C11

STAIR 7

295.13

D1-C6

ALCOVE

111.52

D1-C6A

FEC

0.75

E1-36

PR I MA R Y C AR E HS S

111.05

C1-77C

HOUSEKEEPING

43.56

A1-92A

CL.

34.46

A1-89A 28.06

A1-C1A

FEC

3.17

A1-78

VACANT

115.68

A1-75A

COMPUTER R

76.50

A1-66

PAT TREATM

145.00

A1-26B

DIETARY

64.75

A1-C7

CORR.

157.50

A1-40A 94.50

A1-C15

CORR.

410.50

A1-C15A 2.75

A1-121A

I.C.U. BED

182.92

A1-121D

EXAM/TREAT

179.00

A1-121G

EXAM/TREAT

172.92

A1-90

TOILET

103.91

A1-85

VACANT

308.13

A1-85E

VACANT

90.50

A1-C17

CORR.

134.50

A1-C16

CORR.

272.62

A1-C1B

ST. 5

125.39

A1-40

OR. #1

360.27

A1-C14

CORRIDOR

541.10

A1-32

OFFICE

127.50

A1-106

218.47

A1-123

CLEAN UTIL

104.50

A1-36

ANESTHESIA

115.00

A1-45A

41.17

A1-120 200.67

A1-121E

EXAM/TREAT

171.19

A1-85D

VACANT

22.50

A1-74

RADIOLOGY

A1-C4

CORRIDOR

352.48

A1-34A 66.00

A1-39A 33.00

A1-49A

OR. #5

397.08

A1-31

OFFICE

144.00

A1-45D 103.75

A1-124

CLEANLINEN

67.83

A1-52A

TOILET

108.67

A1-29

ENDOSCOPY #1

206.50

A1-99

VACANT

159.14

A1-5A

STORAGE CLOSET

237.95

A1-103

VACANT

200.56

A1-93

VACANT

291.73

A1-75

125.33

EMS

25.99

A1-67B

H/C TOILET

79.33

A1-28A

234.50

A1-24

TOILET

63.00

A1-51

UTILITY

A1-39

192.33

A1-110

145.17

A1-115

63.00

A1-48

OR. #4

377.25

A1-56

LOUNGE

136.00

A1-30

UTILITY

100.00

A1-121 S.I.C.U.

1,944.69

A1-96A

VACANT

361.42A1-77

VACANT

258.52

A1-71

PAT TREATM

85.62

A1-11 141.83

A1-22

92.00

A1-52

LOUNGE

386.33

A1-37

ANESTHESIA

132.00

A1-42

STORAGE

102.00

A147

OR. #3

338.00

A1-108

PATIENT CARE

A1-104

VACANT

180.50

A1-121F

EXAM/TREAT

165.93

A1-C16C

CRASH CART

13.55

A1-76

VACANT

55.00

A1-25

RECEPTION/

152.25

CORR.

351.05

A1-50

MEDITATION

45.00

A1-54A

BATHROOM

92.17

A1-63 E.C.

56.25

A1-46 29.75

A1-34

CYSTOSCOPY

244.96

A1-45B 120.33

A1-70

PAT TREATM

78.08

A1-C18

118.83

A1-82

VACANT

275.83

A1-62

OR SECRETARY

A1-44

OR. #2

451.40

A1-C15B 2.75

A1-34B

CL.

18.88

A1-58

O.R. SUPER

124.04

A1-68

PAT TREATM

129.77

A1-41

STORAGE

A1-C12A 20.00

A1-112

ICU

112.00

A1-88

TOILET

49.00

A1-38

WAITING RM

159.40

A1-C12C E.C.

4.00

A1-35 51.73

A1-C11

CORRIDOR

A1-C2

CORR.

353.50

A1-C6

CORRIDOR

391.63

A1-C19

VACANT

853.35

A1-33

URODYNAMKG

229.75

A1-C12D

ST 4.

172.08

A1-C21

VACANT

653.48

A1-53

BATHROOM

86.75

A1-54

LOCKER RM.

205.50

A1-114

TOILET

30.00

A1-69

PAT TREATM

286.81

A1-28

STORAGE

329.47

A1-96

VACANT

150.00

A1-94

TOILET

126.00

A1-83A

VACANT

38.54

A1-67

LOCKER RM.

39.75

A1-C16A

F.H. CL.

5.13

A1-121H

EXAM/TREAT

173.33

A1-104A

VACANT

11.00

A1-95

259.60

A165

PATIENT CARE ROOM

165.25

A1-67A

TOILET

27.50

A1-25A

WAITING RM

90.82

A1-57

NITROUS OX

22.50

A1-112A

BATHROOM

67.17

A1-116 184.33

A1-113A 24.11

A1-45C 108.00

A1-125

TOILET

47.67

A1-2

ATTENDING

145.00

A1-3

ATTENDING

130.00

A1-91

EMS

26.00

A1-C19A

VACANT

45.00

A1-73

X-RAY

347.53

A1-80

VACANT

123.25

A1-27

ENDOSCOPY #3

127.00

A1-117

TOILET

50.75

A1-107

33.00

A1-105

TOILET

56.75

A1-122

MED PREP

49.50

A1-100

VACANT

126.25

A1-97

VACANT

308.25

A1-121C

I.C.U. BED

174.00

A1-119 52.83

A1-C21A

VACANT

5.25

A1-85A

VACANT

316.75

A1-73B 40.26

A1-113B 69.33

A1-34C

TOILET

34.00

A1-111 212.92

A1-61

PATIENT HO

274.80

A1-98

VACANT

358.00

A1-1

G.I. SECRT

158.50

A1-92

VACANT

326.19

A1-83

VACANT

107.75

A1-89 245.49

A1-C16B

NOURISH ST

18.63

A1-73A 48.75

A1-65

NURSES ST.

146.25

A1-79

VACANT

117.25

TOILET

59.00

A1-55

LOUNGE-MEN

A1-60

ANESTHESIOLOGY

A1-113

EXAM/TREAT

132.00

A1-43

253.63

A1-109 121.00

A128B

EMS

82.99

A1-102

VACANT

152.08

A1-5

CONFERENCE

1,053.72

A1-121B

I.C.U. BED

174.00

A1-C3

CORR.

399.00

B1-28E

CL.

10.83

B1-28F

CL.

7.63

B1-28A

STORAGE

127.50

B1-28B

GROSSING ROOM

167.53

B1-28C

MEDCHEMSPR

140.08

B1-28D

LABORATORY

309.65

A1-C9

CORRIDOR

344.00

A1-45

CORRIDOR

773.19

A1-101

VACANT

270.00

A1-104B

COMMUN.

12.00

A1-104C

ELECTRICAL

10.50

F.E.C.

D1-C7A

VESTIBULE

254.00

B1-34

ELEV. LOBB

170.26

E1-62

EXAM TREAT

101.33

E1-64

EXAM/TREAT

106.38

E1-C11A

STAIRWAY 8

283.70

E1-6

CHEST X-RA #1

344.79

D1-1

PATIENT

EDUCATION

D1-C8A

MAIN LOBBY

3,196.18

E1-1A

STAIRWAY 1

363.41

PATIENT

REPRESENTATIVE

163.23

E1-2

CLINICAL

86.00

E1-3

MEDICATION

61.27

B1-4B

NRSETRIAGE

70.69

A1-15

CARDIOCATH

442.53

B1-C4

CORR.

588.56

C1-C10A

ST 3.

135.29

B1-20

STRESS LAB

307.36

B1-22

PHARMACY

2,008.53

107.25

A1-19

WAITING ROOM

147.75

A1-118

PRE-ADMIT

339.22

A1-20

EXAM TREAT

183.71

A1-20A

EXAM TREAT

93.83

A1-16A 70.98

A1-16

CARDIAC CATH.

133.71

A1-17

87.75

A1-17A

EXAM

78.00

A1-12

RESP-THERP

287.50

B-135

PULMONARY

106.58 A1-14

PULMONARY/

TESTING LAB

B-136

D.A.V. OFF

184.92

B-136A

EXAM

66.40

B1-34A

NO.5 FRGHT

86.25

B1-34B

NO.4 FRGHT

99.53

A1-8

OFFICE

108.75

A1-9

RECEPTION

116.81

A1-10

CONFERENCE

158.00

A1-11A

LAB

131.83

A1-11B

STORAGE

140.00

A1-11C

OFFICE

149.33

A1-7

MEN TOILET

96.00

A1-6

WOMEN'S RM

90.00

A1-84

VACANT

159.51

A1-C1

CORRIDOR

730.14

A1-84A

VACANT

80.71

A1-87

VACANT

216.76

A1-86

VACANT

91.00

A1-85B

142.67 A1-85C

VACANT

159.83

A1-93A

VACANT

69.89

B1-39A

NURSE PRACTITIONER

118.67

B1-38

ATTENDING

173.38

A1-C3A

CORRIDOR

1,231.49

A1-4

G.I. FELLOW OFFICE

187.50

B1-22E

INVESTIGINAL

77.00

B1-22F

VAULT

71.75

B1-21

I V ORDERS

314.40

B1-17B

COORDINATOR

63.23

B1-15

ELEV. LOBB

360.72

B1-15C

ELEVATOR 3

80.57

B1-15B

ELEVATOR 2

75.83

B1-15A

ELEVATOR 1

92.10

B1-13

ECHO LAB

1,280.23

C1-27

PATIENT

B1-11

DOC WRK RM

503.88

B1-5C

SUPPORT

328.49

B1-4A

NRSETRIAGE

59.83

B1-5B

OFFICE

114.48

B1-7E

OFFICE

75.59

B1-5A

LOUNGE

106.85

B1-7B

RELEASEINF

771.89

B1-7D

OFFICE

98.71

B1-7C

OFFICE

90.99

B1-6B

RECEPTION

965.83

B1-1

CENT LOBBY

3,631.59

B1-1C

PHARMCOPAY

102.89 B1-1B

136.96

B1-1A

P.I. OFFICE

133.76

B1-8

WOMEN'S RM

71.39

B1-7A

TRANSCRITI

698.06

B1-6A

CENTRAL INTAKE

463.52

B1-C1

LOBBY

607.66

B1-C1A

LOBBY

1,307.37

C1-33C

LOUNGE

282.16

C1-C2

CORRIDOR

949.55

B1-C2

CORR.

688.92

B1-22D

SUPERVISOR

161.34

C1-77

841.75

C1-79A

LAB.

94.78

C1-79

BLOOD DRAWING ROOM

377.40

C1-82

LABORATORY

248.18

C1-50

IRM OFFICE

291.67

C1-50A 234.57

C150A

278.25

C150B

PHYSICIAN'S OFFICE

219.06

C1-50D

VESTIBULE

87.39

C1-3

DECEDENT

160.65

B1-6C

ESCORT SER

380.60

A1-59

CHIEF

132.28

A1-11D

PULMONARY

199.80

ASST. CHIEF MEDICAL

TECHNOLOGIST

/BLOOD BANK

O.D. RM.

O.D. RM. O.D. RM. O.D. RM. UNIT

ADMINISTRATION

LABORATORY

SUPERVISOR

SECRETARY

OFFICE

LAB MEDICAL

SERVICE

FLOW

CYTOMETERY

ROOM

HEMATOLOGY/

ONCOLOGY

DEPARTMENT

C1-72A

FELLOW

CENTER

DEPARTMENT OF ONCOLOGY

HEMATOLOGY

/ONCOLOGY

CONFERENCE ROOM

PHYSICIAN'S

PHYSICIAN'S OFFICE

ASSISTANT SURGICAL

SERVICE

ASSISTANT

COORDINATOR

LABORATORY

OFFICE

REST

ROOM

BLOOD DRAWING ROOM

DRUG

PHARMACY

EXAM ROOM #2

EXAM ROOM #1

CARDIOLOGY

ECHO LAB

EKG

STRESS LAB

CHAPLIN

OFFICE

SUITE

ER

CLEAN

LINES

ROLLING SHUTTERS

UTILITY

STORAGE

EXAM ROOM STORAGE

NURSE MANAGER

ER

STORAGE

WAITING ACE

E M E R G E N C Y

R O O M

C127A

CLINAL

PHARMACIST

B1-7F

ATTENDING

NURSE

BILLING

INQUIRES

ROOM

STORAGE

TOILET

SCHEDULING UNIT

RESIDENT

PHARMACIST

SUPERVISOR

E1-27

E1-26

PGM

ASSISTANT

E1-24

HOUSEKEEPER

E1-23

CLOSET

E1-38

EXAM ROOM -II

# 10

# 9

# 11

EXAM ROOM #14

# 3

# 8# 7

# 6 # 9

# 5 # 12

# 4 # 8

# 7

# 6

# 4

# 3

# 2

# 1

3 2 1

EMS ROOM

COMPUTER

ROOM

A1-118

A1-113A

MEN

LOCKER

STORAGE ROOM

ICU

WAITING ROOM

125.75

COORDINATOR

CLEAN

SUPPLY ROOM

ROOM #2

EXAM

ROOM #3

B1-13C

HOTTER ROOM

PAT-ASU UROLOGY

STORAGE ROOM

RECOVERY ROOM 6

RECOVERY ROOM 7

133.00

SUPPLY ROOM

CONFERENCE

ROOM 143.75

125.00

GAS

STORAGE

36.00

A1-52

MEN LOCKER RM.

A1-64

SPECIAL

PROCEDURE

EXAM ROOM #7

143.25

VACANT

VACANT

99.19

MEN'S

D1-15A

PATIENT EDUCATION

MEN'S

#3#2

ROOM #2

ORTHO EXAM

OFFICE

D1-35

100.00

D1-C13

RECEPTIONIST

D1-10

D1-37 ORTHO

ROOM #3

ORTHO EXAM

ROOM #4

EXAM EXAM ROOM #6

ROOM #5

119.80

PROGRAM

SERVICE

OFFICER

PROGRAMME

107.29

WORK ROOM

D1-52

C CLOSET

D1-51

E CLOSET

119.57

E1-1

ANALYST

SUPPORT

LOCKER ROOM

EXAM ROOM

PHARMACY

B1-28H

OFFICE

B1-28G

CYTOLOGY

B1-C1

AISLE WAY

B1-28I

DRY STORAGE

B1-28J

GROSS-TISS.

B-137

OFFICE

66.40

PR OG R AMME S UP P OR T

VACANT

VACANT

ROOM

ROOM

OFFICE

PHARMACIST

OFFICE

AFFAIRS

LAB

MGR

PHYSICIAN

SERV.

STRG.R

OFANESTHESIA

183.38

ADVOCATE

ROOM

EXAM

COORDINATOR

PRACTITIONER

PRACTITIONER

TREAT

EXAM

E1-C5A

PRIMARY CARE

68.00

SECERETARY

CARE ACOS

EXAM ROOM

SUPPORT

OFFICE

SHAFT.11

DN

SH A FT . 1 2

SH A FT . 9

UP

UP

DN

SH A FT . 1 4

SH A FT . 1 3

SH AF T . 1

UP DN

SH A FT . 7

SH A FT . 8

DN

UP UP

DN

SHAFT

SFT.2 5

DN

DN UP

UP DN

#1 #3

#2

1ST

A1-C12B

COMMUICATI

UP

DN

OS OS

L V

D

M

WP

LPD

C P

M

J

J

J

J

R

C P

CP

J J

J

J

RR

RRR

J

T S

F S

E-100

BUILDING 7

EXISTING BUILDING 7

TRANSFORMER

XW

ATS-SPS

POWER FOR EXTERIOR LIFT.

PROVIDE WEATHERPROOF ENCLOSURE.

BASIS OF DESIGN: SAVARIA V-1504

POWER: 20A, 120V, 1PH

G,WP

P

MDPU

LE LELLEL

DS-MDPU

W

AC-1

CU-1DS-CU-1

DS-MWSUDS-MSGUDS-CWP

T-SPS

T-LTPSHTPS

LTPS

GEN-SPS

8 88

HTPS-4 HTPS-4 HTPS-4

HTPS- 4

HTPS-4 HTPS-4

HTPS-4

HTPS-4

HTPS-4

LTPS-7

LTPS-7

LTPS-7

30cd 30cd

270 270

G,WP

LTPS-7

P

HTPS-4

POWER FOR EXTERIOR LIFT.

PROVIDE WEATHERPROOF ENCLOSURE.

BASIS OF DESIGN: SAVARIA M-1504

POWER: 30A, 120V, 1PH

LTPS-9

LTPS-9

LTPS-9

MSWU

MGSU

HTPS-7

G,WP

G,WP

G,WP

LTPS-11

LTPS-12

HTPS-8

HTPS-6

18 18

ICS

S S

S

S HTPS-5

HTPS-5

HTPS-5

HTPS-5

HTPS-9

LTPS-7

LTPS-7P

P

HTPS-4

HTPS-4

DS-MSSU

DS-MSSU-CWP

TEMP

SPS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

VA Project No.

AG Project No.

A u to d e s k D o c s

/0

N o rt h p o rt

S P

S /0

N o rt h p o rt

S P

S

R

M E

P F

P F

A T

.r v t

/2

/2

:3

:3

P

M

E-100

ELECTRICAL OVERALL GROUND

FLOOR PLAN

RENOVATE STERILE

PROCESSING DEPARTMENT,

BUILDING NO. 200

NORTHPORT VA

0123025

B200

06/18/2025 CJM IMW

100% CONSTRUCTION

DOCUMENTS

632-12-106

CODED NOTES:

DRAWING NOTES:

1" = 40'-0"1 ELECTRICAL OVERALL GROUND FLOOR PLAN - TEMPORARY

3/32" = 1'-0"2 ENLARGED PLAN - TEMPORARY TRAILER

N 0 20' 40' 80' 120'

1" = 40'

0 8' 16' 24' 32'

3/32" = 1'-0"

N.T.S.

KEY PLAN TEMP SPS

1. CONCRETE AND CMU WALLS, CONCRETE PADS/SLABS ON GRADE, AND ALL ASSOCIATED EQUIPMENT

AND INFRASTRUCTURE INSTALLED FOR CONTINUATION OF MEDICAL CENTER OPERATIONAL

REQUIREMENTS ARE TEMPORARY AND SHALL BE REMOVED AND THE AREAS AFFECTED RESTORED

TO PRIOR ORIGINAL CONDITIONS UPON FUNCTIONAL COMPLETION OF THE NEW SPECIAL

PROCESSES SERVICES SPACES AND/OR THE APPROVAL OF THE PROJECT COR.

2. ALL EQUIPMENT TO BE INSTALLED OUTDOORS SHALL BE NEMA 3R, EXTERIOR RATED.

3. COORDINATE ALL POWER OUTAGES WITH COR (4) WEEKS IN ADVANCE.

4. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR THE SINGLE POINT CONNECTION TO THE MDPU, CWP, MSGU, AND MWSU. TEMPORARY SPS VENDOR IS RESPONSIBLE FOR ALL CONNECTIONS FROM

THE MDPU, CWP, MSGU, AND MWSU TO THE TEMPORARY SPS EQUIPMENT.

5. CONNECT NEW FIRE ALARM NOTIFICATION AND INITIATION DEVICES TO EXISTING FIRE ALARM NAC

PANEL IN ELECTRICAL CLOSET C1-1.

COORDINATE EXACT CONDUIT ROUTING FOR TEMPORARY SPS WITH ARCHITECT, CIVIL AND VA

ELECTRICAL SHOP PRIOR TO CONSTRUCTION.

EXISTING BUILDING 7 TRANSFORMER IS A LOOP FEED TRANSFORMER USED AS A RADIAL FEED

TRANSFORMER WITH DEADFRONT ARRESTERS ON THE 'HV B' TERMINALS. DEADBREAK ARRESTERS SHALL BE DISCONNECTED, AND NEW LOAD BREAK ELBOWS SHALL BE INSTALLED. PROVIDE NEW 15kV 3#2/0AWG IN 5" CONDUIT AND CONNECT TO THE 'HV B' SIDE OF THE TRANSFORMER. PROVIDE A 316

STAINLESS STEEL NEMA 4X SIDE BOX TO PULL THE FEEDERS THROUGH AND DOWN INTO THE

UNDERGROUND CONDUITS. COORDINATE ALL CONNECTIONS WITH THE VA, CIVIL, AND STRUCTURAL

DRAWINGS PRIOR TO CONSTRUCTION.

PROVIDE STAINLESS STEEL UNISTRUT RACK TO MOUNT PANELS HTPS AND LTPS.

ROUTE UNDERGROUND FEEDERS FROM ATS-SPS TO PANEL HTPS.

ROUTE UNDERGROUND FEEDERS FROM PANEL HTPS TO DS-MDPU.

PROVIDE STAINLESS STEEL UNISTRUT RACK TO MOUNT DISCONNECT DS-MDPU.

APPROXIMATE LOCATION OF MPDU (MOBILE POWER DISTRIBUTION UNIT). BASIS OF DESIGN IS MMIC MEDICAL SYSTEMS. BASIS OF DESIGN POWER REQUIREMENTS ARE 600A, 480V, 3PH. ANY DEVIATION FROM BASIS OF DESIGN IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND SHALL BE

PROVIDED AT NO ADDITIONAL COST TO THE VA.”

EQUIPMENT POWERED BY MDPU AS BASIS OF DESIGN. ANY DEVIATION FROM BASIS OF DESIGN IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND SHALL BE PROVIDED AT NO ADDITIONAL COST

TO THE VA.”

PROVIDE WEATHERPROOF FIRE ALARM NOTIFICATION DEVICE. COORDINATE FIRE ALARM

CONNECTION AS REQUIRED TO CONNECT BACK TO EXISTING FIRE ALARM PANEL IN ROOM D0-3.

CONTINUE ROUTING OF CONDUIT AND CONDUCTOR BACK TO THE EXISTING 300kVA, 13.2kV-208/120V

TRANSFORMER SERVING BUILDING 7.

PROVIDE 3' x 3' CONCRETE HANDHOLE FOR THE INSTALLATION OF MEDIUM VOLTAGE CABLE. WHEN

THE TEMPORARY SPS IS REMOVED, DISCONNECT THE MEDIUM VOLTAGE CABLE FROM THE

TRANSFORMER T-SPS, PULL BACK THE MEDIUM VOLTAGE CABLE TO THE HANDHOLE, CAP THE ENDS

OF THE MEDIUM VOLTAGE CABLE, AND MAINTAIN FOR FUTURE USE.

PROVIDE TASK LIGHTING AS SHOWN ON THE ELECTRICAL EQUIPMENT SUPPORT DETAIL ON SHEET E-501.

PROVIDE ELECTRICAL CONNECTIONS TO RAYCHEM 920 (OR EQUAL) HEAT TRACE CONTROLLERS.

PLUMBING CONTRACTOR SHALL PROVIDE INSTALLATION OF HEAT TRACE CABLE ON PIPING AND

ELECTRICAL CONTRACTOR TO FURNISH CONTROLLER. ELECTRICAL CONTRACTOR TO INSTALL

CONTROLLER AND PROVIDE CONDUIT AND ASSOCIATED CIRCUIT WIRING FROM ELECTRICAL PANEL TO

CONTROLLER, FROM CONTROLLER TO HEAT TRACE WIRE. COORDINATE FINAL ELECTRICAL

REQUIREMENTS WITH PLUMBING CONTRACTOR PRIOR TO FINAL INSTALLATION AS RUN LENGTHS CAN IMPACT FINAL ELECTRICAL DEMAND. SEE SHEET E-801 FOR CIRCUITING INFORMATION. ANY DEVIATION FROM BASIS OF DESIGN IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND SHALL BE

PROVIDED AT NO ADDITIONAL COST TO THE VA.”

PROVIDE 120V, 1PH POWER FOR MOTORIZED CONTROLLED DAMPER. COORDINATE FINAL LOCATION

AND CONNECTION REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO INSTALLATION.

PROVIDE NEW LOCKED ENCLOSURE IN THIS AREA FOR FIBER PASS THROUGH AND PULL ASSISTANCE.

PROVIDE ALUMINUM RMC FOR FIBER RUN ALONG WALK WAY TO SPS TRAILER. PULL MULTIMODE FIBER

THROUGH FROM ROOM C1-50 INTO SPS TRAILER THROUGH CONDUIT. COORDINATE FIBER

CONNECTION AS REQUIRED TO CONNECT BACK TO TELECOM ROOM.

PROVIDE THREE (3) SETS OF FIRE ALARM CONTACTS FOR SUPERVISORY, ALARM, AND TROUBLE CONDITIONS. ALL FEEDERS SHALL BE INSTALLED IN ALUMINUM RMC. COORDINATE CONNECTION AS REQUIRED TO CONNECT BACK TO EXISTING FIRE ALARM PANEL IN ROOM D0-3. COORDINATE EXACT

LOCATIONS AND INSTALLATION REQUIREMENTS WITH MMIC PRIOR TO CONSTRUCTION.

PROVIDE (1) LOCKABLE 1' x 2' TIER 5 HANDHOLE FOR DATA TO COMBINATION CARD READER/NUMERIC KEYPAD. PROVIDE 2#8AWG, 1#8AWG GROUND IN 1-1/2" CONDUIT A MINIMUM OF 12" DEEP WITH WARNING TRACER TAPE A MINIMUM OF 6" ABOVE CONDUIT. PROVIDE A NEMA 4 ENCLOSURE TO HOUSE

A FIBER CONVERTER AND POE INJECTOR. COORDINATE EXACT LOCATION AND MOUNTING

REQUIREMENTS OF JUNCTION BOX WITH VA AND CIVIL DRAWINGS PRIOR TO CONSTRUCTION.

PROVIDE NEW AREA SITE LUMINAIRE(S) WITH NEW 15' ROUND POLE AS SHOWN ON PLAN AND THE LIGHTING FIXTURE SCHEDULE SHOWN ON SHEET E-601. PROVIDE (1) LIGHTING POLE-MOUNTED, PTZ

CAMERA LIGHTING POLE-MOUNTED AT 12'-0". PROVIDE LIGHTING POLE MOUNTED EQUIPMENT

ENCLOSURE. PROVIDE QUAZITE 1' x 2' TIER 5 HANDHOLE LOCATED AT THE BASE OF EACH LIGHTING POLE WITH A CAMERA. ALL LOW VOLTAGE CABLING FOR CAMERA AND ASSOCIATED EQUIPMENT MUST

BE ROUTED THROUGH PULL BOX. REFER TO TYPICAL LIGHTING POLE MOUNTED EQUIPMENT

ENCLOSURE DETAIL ON SHEET T-501 FOR ADDITIONAL INFORMATION. COORDINATE EXACT LOCATION

AND INSTALLATION REQUIREMENTS WITH CIVIL DRAWINGS PRIOR TO INSTALLATION.

PROVIDE CEILING MOUNTED DOME STYLE MULTI-LENS CAMERA.

COORDINATE THE REMOVAL AND REINSTALLATION OF THE EXISTING CAMERA AND SPEAKER LOCATED

ON THE EXTERIOR OF THE BUILDING WITH THE VA PRIOR TO CONSTRUCTION.

PROVIDE INTERCOM CALL STATION INSIDE THE VESTIBULE FOR COMMUNICATION WITH THE

TEMPORARY SPS TRAILERS. COORDINATE FINAL LOCATION AND CONNECTION REQUIREMENTS WITH

THE VA AND TEMPORARY TRAILER MANUFACTURER PRIOR TO INSTALLATION.

PROVIDE FIRE ALARM RELAYS AND ALL ASSOCIATED RACEWAY FOR TAMPER AND WATER FLOW

SWITCHES AT ENTRANCE TO BUILDING. COORDINATE EXACT LOCATION, QUANTITY OF DEVICES, AND

INSTALLATION REQUIREMENTS WITH FIRE PROTECTION CONTRACTOR PRIOR TO CONSTRUCTION.

N.T.S.

3 BUILDING 7 TRANSFORMER - PRIMARY COMPARTMENT

ANY DEVIATION FROM BASIS OF DESIGN IS THE

RESPONSIBILITY OF THE GENERAL CONTRACTOR AND

SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE VA.”

Revisions Date

1 ADDENDUM 1 09/03/2025

BASEMENT

ALL ELECTRICAL PANELS AND

TRANSFORMERS SHOWN ON THE RISER

DIAGRAM ARE EXISTING.

PANELS IN BOLD ARE PANELS TO BE UTILIZED

FOR THIS RENOVATION PROJECT.

N = NORMAL POWER

C = CRITICAL POWER

LS = LIFE SAFETY

CLB-CD

CLB-C

CHB-C

NLB-C

NLB-CD2

ELEC. CLOSET CB-2

CHB-CD

NLB-CD

NHB-C

NLB-C2

NL1-C3

CL1-C

480V- 120/208V

#1/0

T-CLB-CD

112.5 kVA

CL1-C1

CL1-C

CH1-C

NL1-C

NL1-C2

EH1-C

1ST FLOOR

TO CSWB#2

TO NHB-C

VIA XFMR

100 150

NO

POWER

PANEL

OFF

ELEC. CLOSET CB-1

TO 2001 B1

TO EM SWBD

ELEC. CLOSET C1-2 ELEC. CLOSET C1-1

N NN NC

LS

CNCC

C C CN N N

TO CHB-CD

TO CHB-C

NHKD

TO NSWBD-C2

MAIN ELEC. ROOM A011A-E

2ND FLOOR

NL2-C

TO NLB-CD

N

N

CHB-AD

TO CSWB#2

C

ELEC. ROOM A011D

CH2-PH

C

2 22

NOTES: (APPLICABLE TO LUMINAIRE SCHEDULE ONLY)

1. CATALOG NUMBERS FOR LUMINAIRES INDICATE THE TYPE AND QUALITY OF THE LUMINAIRE TO BE PROVIDED BY THE CONTRACTOR AND ARE GENERAL IN NATURE. THE CATALOG NUMBERS ARE NOT INTENDED TO INDICATE AN ACTUAL ORDER MODEL NUMBER.

2. PROVIDE EXIT SIGNS WITH SINGLE FACE OR DOUBLE FACE AND WITH OR WITHOUT CHEVRONS AS INDICATED ON THE DRAWINGS.

3. EMERGENCY FIXTURES AND BATTERY PACKS ARE TO BE CONNECTED TO CONSTANT HOT LEG (UN-SWITCHED) OF CIRCUIT INDICATED.

4. ALL MOUNTING HEIGHTS SHALL BE AS INDICATED ON THE DRAWINGS, LIGHTING FIXTURE SCHEDULE, OR AS DIRECTED BY ARCHITECT OR ENGINEER. MOUNTING HEIGHTS OF WALL MOUNTED LUMINAIRES SHALL BE MEASURED FROM THE FINISHED FLOOR TO THE CENTERLINE OF THE LUMINAIRE. MOUNTING HEIGHTS OF CEILING SUSPENDED LUMINAIRES SHALL BE MEASURED FROM THE FINISHED FLOOR TO THE BOTTOM OF THE LUMINAIRE.

5. WHERE FIXTURES ARE TO BE INSTALLED IN A HARD CEILING, PROVIDE A DRY WALL FRAMING KIT.

TO

G

G

LE

S W

IT

C

H (E

S) C

E

IL

IN

G

/W

AL

L M

O U

N

TE

D O

C C

U P

AN

C

Y S

EN

SO

R (S

W

AL

L

BO

X O

C C

U

PA

N C

Y

SE

N

SO

R (S

) W

IT

H S

IN

G

LE

O

U

TP

U T

R E

LA

Y

W

AL

L

BO

X O

C C

U

PA

N C

Y

SE

N S

O R

(S ) W

IT

H

D

IM

M

IN

G

LU

M

IN

AI

R E

W

IT

H B

U

IL

T-

IN

O C

C U

P

AN

C Y

S

EN

SO

R

- D

IG

IT

A

L

SW

IT

C

H (E

S) C

E

IL

IN

G

/W A

LL

M

O U

N

TE

D O

C C

U P

AN

C

Y

SE

N

SO

R (S

IN

D

O O

R P

H O

TO

SE

N

SO

R (S

IN

TE

G R

A L

IU

TD

O O

R P

H O

TO

C

EL

L

AS

TR

O N

O M

IC

AL

T

IM

EC

LO

C K

FR

ES

C A

SW

IT

C H

IN

G

ST

E

P- D

IM

M

IN

G

FU

LL

R

AN

G E

D

IM

M

IN

G C

E N

TR

A

LI

ZE

D C

IR

C

AD

IA

N R

H

YT

H M

C C

T C

O N

TR

O

L

VA

C

AN

C

Y

SE

N S

O R

T

IM

E O

U T/

D

EL

AY

(I

N M

IN

U

TE

S

LI

G

H

TS

M

AN

U

AL

O N

LI

G

H

TS

A U

TO

M

AT

IC

O N

T O

L

IG

H

T

LE

V

EL

U

PO

N O

C C

U

PA

N C

Y

LI

G

H

TS

A U

TO

M

AT

IC

O N

T O

0%

L

IG

H T

LE

V

EL

U

PO

N

O C

C U

PA

N

C Y, M

A N

U

AL

O N

TI

M

EC

LO

C K

SC

H

ED

U

LE

D

"O N

" T

IM

E

TI

M

EC

LO

C K

SC

H

ED

U

LE

D

"O

FF

" T

IM

E

O C

C . S

EN

S

O R

O

VE

R R

ID

E

TI

M

EC

LO

C K

D U

R

IN

G "O

FF

" H

O U

R S

D A

YL

IG

H

TI

N G

-D

IM

L

IG

H

TS

T O

M

AI

N

TA

IN

M

IN

IM

U M

0F

C A

T

" A

FF

LINE VOLTAGE CONTROL DEVICE LOW VOLTAGE CONTROL DEVICE SWITCHING/DIMMING MISCELLANEOUS

CORRIDORS

TYPICAL SPACE TYPE

- - - - - - X - - - - X-- - 20 X 5AM 10PM

X

X

X - -

NOTES

COORDINATE SCHEDULE WITH COR.

OFFICES - - - - - - X - - - - X-- - X -X - -

DECONTAMINATION / SCOPE PROCESSING

X X - - - - - - - - - X - - - - -- X-

CLEAN SUPPLY

HAC

ANTEROOM

CONFERENCE/BREAK

MENS/WOMENS LOCKER & BATHROOMS

CART WASH / CARTS SOILED & CLEAN

TRAILER CORRIDOR

X X X 5AM 10PMX COORDINATE SCHEDULE WITH COR.

- - - -- - - - - - X - - - - X-- - - -X - -

- - - -- - - - - - X - - - - X-- - - -X - -

X -- - - - - - - - - - -- - - -X X X 5AM 10PMX COORDINATE SCHEDULE WITH COR.

X -- - - - - - - - - - -- - - -X X X 5AM 10PMX COORDINATE SCHEDULE WITH COR.

X -- - - - - - - - - - -- - - -X X X 5AM 10PMX COORDINATE SCHEDULE WITH COR.

X -- - - - - - - - - - -- - - -X X X 5AM 10PMX COORDINATE SCHEDULE WITH COR.

11 - - - -X X - - - - - - X - - X - - - - -- X-EXTERIOR / PENTHOUSE 20

G

BUILDING 7

NEW 750kVA, 480V, 3PH

TRANSFORMER

MDPU

MOBILE POWER

DISTRIBUTION UNIT

GEN-SPS

1MW

480Y/277V

NEMA 3R

SOUND LEVEL 1

96 HR SUB BASE TANK

DS-MDPU

DISCONNECT SWITCH

600V, 600A, 3P, 600A FUSED,

NEMA 3R

2 SETS OF (4#600KCMIL +

1#1/0AWG GND IN 4" C.)

T-SPS

750kVA 13.2kV- 480/277V

800 A

277/480V, 3-PHASE, 4 WIRE(65,000 AIC)

HTPS

EXISTING 300kVA, 208V, 3PH TRANSFORMER

T-BLDG 7

300kVA

13.2kV- 208/120V

225 T-LTPS

112.5kVA

480V- 208/120V

#2

LTPS

(10,000 AIC)

#2/0

2 SETS OF (4#3/0AWG +

1#2AWG GND IN 2" C.)

NEMA 3R, EXTERIOR RATED

NEMA 3R,

EXTERIOR RATED

15kV 3#2/0AWG IN 5" C.

ATS-SPS

800A, 480V, 4P, NEMA 3R

NEW 112.5kVA, 208V, 3PH TRANSFORMER

2 SETS OF (4#350KCMIL + 1#1/0AWG GND IN 2-1/2" C.)

3#4/0AWG + 1#6AWG GND IN 2-1/2" C.

200 DS-MSSU

DISCONNECT SWITCH

240V, 200A, 3P, 200A FUSED,

NEMA 3R

DS-MSSU-CWP

DISCONNECT SWITCH

600V, 30A, 3P, 15A FUSED,

NEMA 3R

4#12AWG + 1#12AWG GND IN 3/4" C.

4#3/0AWG + 1#6AWG

GND IN 2-1/2" C.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

VA Project No.

AG Project No.

A u to d e s k D o c s

/0

N o rt h p o rt

S P

S /0

N o rt h p o rt

S P

S

R

M E

P F

P F

A T

.r v t

/2

/2

:3

:0

P

M

E-601

ELECTRICAL DIAGRAMS RENOVATE STERILE

PROCESSING DEPARTMENT,

BUILDING NO. 200

NORTHPORT VA

0123025

06/18/2025 CJM IMW

100% CONSTRUCTION

DOCUMENTS

632-12-106

LIGHTING FIXTURE SCHEDULE

TYPE DESCRIPTION MANUFACTURER MODEL VOLTAGE VA

LAMP

TYPE

FIXTURE

LUMENS

FIXTURE

COLOR TEMP

(K) DRIVER/BALLAST COMMENTS

A2 2'x2', LED, CLEANROOM RECESSED LUMINAIRE COOPER LIGHTING BAA-FLR-MC-22-35-35-CA125 277 V 31 VA LED 3560 3500K 10%, 0-10V DIMMING

B2 2'x2', LED LAY-IN FIXTURE COOPER LIGHTING 22FPSL2SCT3-A3/8-4/18GDIM 277 V 31 VA LED 3440 3500K 10%, 0-10V DIMMING

D 6" LED DOWNLIGHT LITHONIA LDN6-35/15-LO6-AR-LSS-MVOLT-GZ10 277 V 18 VA LED 1500 3500K 10%, 0-10V DIMMING

L 4' SURFACE MOUNTED LED STRIP FIXTURE LITHONIA CSVT-L48-3000L-MVOLT-35K-80CRI-WLFEND2 277 V 24 VA LED 3000 3500K 10%, 0-10V DIMMING PROVIDE 'OPTION 'STSL' STAINLESS STEEL LATCHES.

L (120 V) 4' SURFACE MOUNTED LED STRIP FIXTURE LITHONIA CSVT-L48-3000L-MVOLT-35K-80CRI-WLFEND2 120 V 24 VA LED 3000 3500K 10%, 0-10V DIMMING PROVIDE 'OPTION 'STSL' STAINLESS STEEL LATCHES.

LE 4' SURFACE MOUNTED LED STRIP FIXTURE LITHONIA CSVT-L48-3000L-MVOLT-35K-80CRI-IE7WCP-WLFEND2 277 V 24 VA LED 3000 3500K 10%, 0-10V DIMMING PROVIDE 'OPTION 'STSL' STAINLESS STEEL LATCHES.

LE (120 V) 4' SURFACE MOUNTED LED STRIP FIXTURE LITHONIA CSVT-L48-3000L-MVOLT-35K-80CRI-IE7WCP-WLFEND2 120 V 24 VA LED 3000 3500K 10%, 0-10V DIMMING PROVIDE 'OPTION 'STSL' STAINLESS STEEL LATCHES.

P RECESSED LINEAR LED FIXTURE LITHONIA IDMW2-L24-2000LM-ACL-MD-MVOLT-GZ10-35K-80CRI 277 V 27 VA LED 3000 3500K 10%, 0-10V DIMMING

S AREA / SITE LUMINAIRE - 1 HEAD COOPER LIGHTING BAA-GALN-SA2D-840-U-T3-BK

POLE: RSS415SY21X

277 V 63 VA LED 9180 4000K N/A MOUNTED AT 15' AFG. FIXTURE SHALL BE

CONTROLLED BY INTEGRAL PHOTOCELL.

T LED STRIP FIXTURE, WET LOCATION METALUX BAA-4VT3-SL3C3-G-UNV 120 V 37 VA LED 5129 3500K N/A COORDINATE MOUNTING HEIGHT WITH THE

MECHANICAL EQUIPMENT INSTALLED.

W WALL MOUNT EXTERIOR LED FIXTURE WITH PHOTOCELL, BUTTON TYPE LITHONIA WDGE3-LED-P1-40K-80CRI-R3-MVOLT-SRM-E20WC-BAA-PIR1FC3V 277 V 52 VA LED 7000 4000K N/A FIXTURE SHALL BE CONTROLLED BY INTEGRAL

PHOTOCELL AND MOTION SENSOR. MOUNT AT 7'-6"

AFF.

W (120 V) WALL MOUNT EXTERIOR LED FIXTURE WITH PHOTOCELL, BUTTON TYPE LITHONIA WDGE3-LED-P1-40K-80CRI-R3-MVOLT-SRM-E20WC-BAA-PIR1FC3V 120 V 52 VA LED 7000 4000K N/A FIXTURE SHALL BE CONTROLLED BY INTEGRAL

PHOTOCELL AND MOTION SENSOR. MOUNT AT 7'-6"

AFF.

X RECESSED EDGE LIT LED EXIT SIGN, RED LETTERS, SINGLE OR DOUBLE FACE LITHONIA EDGR 277 V 5 VA LED N/A N/A N/A

XW RECESSED EDGE LIT LED EXIT SIGN, RED LETTERS, SINGLE OR DOUBLE FACE, WETLOCATION LITHONIA WTLE 277 V 4 VA LED N/A N/A N/A

N.T.S.

1 PARTIAL ELECTRICAL RISER DIAGRAM - MAIN BUILDING

N.T.S.

3 LIGHTING CONTROL MATRIX

N.T.S.

2 ELECTRICAL RISER DIAGRAM - TEMPORARY SPS

EQUIPMENT SCHEDULE

EQUIPMENT NAME IDENTIFICATION HP FLA MCA VOLT / PH / LOAD (VA) MOCP

CB

AMPS PANEL CKT # FEEDER SIZE CONDUIT MOTOR STARTING DISC MEANS COMMENTS

200-ACC-SPD AIR COOLED CHILLER - - 37 480 V/3-24608 VA 50 50 CH2-PH 7,9,11 (3) #6 AWG + #10 AWG GND 1" NA DS-200-ACC-SPD -

200-AHU-SPD AIR HANDLING UNIT - 31 38 480 V/3-25773 VA 40 40 CH2-PH 1,3,5 (3) #8 AWG + #10 AWG GND EXISTING NA DS-200-AHU-SPD EXISTING BREAKER SPACE AND CONDUIT TO BE REUSED.

200-CHWP-1 MECHANICAL PUMP 1 - - 480 V/3-1746 VA - 20 CH2-PH 2,4,6 (3) #12 AWG + #12 AWG GND 3/4" NA TS-200-CHWP-1 -

200-CHWP-2 MECHANICAL PUMP 1 - - 480 V/3-1746 VA - 20 CH2-PH 8,10,12 (3) #12 AWG + #12 AWG GND 3/4" NA TS-200-CHWP-2 -

200-CRU-SPD STEAM CONDENSATE RETURN PUMP (2) 3/4 - - 480 V/3-3000 VA - 20 CHB-AD 21,23,25 (3) #12 AWG + #12 AWG GND 3/4" NA DS-200-CRU-SPD -

200-CSG-SPD STEAM-TO-STEAM GENERATOR - - - 120 V/1-200 VA - 20 CLB-C 24 (2) #12 AWG + #12 AWG GND 3/4" NA TS-200-CSG-SPD -

200-EF-SPD-C EXHAUST FAN 3 - - 480 V/3-3991 VA - 20 CH2-PH 13,15,17 (3) #12 AWG + #12 AWG GND 3/4" NA DS-200-EF-SPD-C -

200-EF-SPD-D EXHAUST FAN 3 - - 480 V/3-3991 VA - 20 CH2-PH 19,21,23 (3) #12 AWG + #12 AWG GND 3/4" NA DS-200-EF-SPD-D -

AC-1 / CU-1 SPLIT SYSTEM - - 22 208 V/1-3661 VA 30 30 LTPS 2,4 (2) #10 AWG + #10 AWG GND 3/4" NA DS-CU-1 INDOOR UNIT POWERED BY OUTDOOR UNIT.

CUH-1 STEAM UNIT HEATER 1/60 - - 120 V/1-50 VA - 20 NL2-C 23 (2) #12 AWG + #12 AWG GND 3/4" NA TS-CUH-1 -

GFS-1 GLYCOL FEED SYSTEM 1/3 - - 120 V/1-864 VA - 20 NL2-C 21 (2) #12 AWG + #12 AWG GND 3/4" NA N/A -

P-2 CIRCULATION PUMP 1/100 - - 120 V/1-180 VA - 20 CL1-C1 34 (2) #12 AWG + #12 AWG GND 3/4" NA N/A -

P-3 CIRCULATION PUMP 1/35 - - 120 V/1-200 VA - 20 CL1-C1 36 (2) #12 AWG + #12 AWG GND 3/4" NA TS-P-3 -

RO-1 REVERSE OSMOSIS PUMP 5 - - 480 V/3-6319 VA 20 20 CHB-AD 26,28,30 (3) #12 AWG + #12 AWG GND 3/4" NA DS-RO-1 -

RO-2 REVERSE OSMOSIS PUMP 5 - - 480 V/3-6319 VA 20 20 CHB-AD 27,29,31 (3) #12 AWG + #12 AWG GND 3/4" NA DS-RO-2 -

RP-1 RO BOOSTER PUMP 3/4 - - 120 V/1-1330 VA 20 20 CLB-C 1 (2) #12 AWG + #12 AWG GND 3/4" NA TS-RP-1 -

RP-2 RO BOOSTER PUMP 5 - - 480 V/3-6319 VA 20 20 CHB-AD 32,34,36 (3) #12 AWG + #12 AWG GND 3/4" NA DS-RP-2 -

TP-1 TRAP PRIMER - 0.5 - 120 V/1-50 VA - 20 NL1-C 36 (2) #12 AWG + #12 AWG GND 3/4" NA TS-TP-1 -

DISCONNECT SCHEDULE

DISC NAME TYPE OF EQUIPMENT VOLTAGE RATING ENCLOSURE RATING DISC. AMP/POLE FUSE SIZE DISCONNECT NOTES

DS-200-ACC-SPD FUSED DISCONNECT SWITCH 600V NEMA 3R 50A/3P 50A -

DS-200-AHU-SPD FUSED DISCONNECT SWITCH 600V NEMA 3R 40A/3P 40A -

DS-200-CRU-SPD NON-FUSED DISCONNECT SWITCH 600V NEMA 3R 30A/3P 30A -

DS-200-EF-SPD-C FUSED DISCONNECT SWITCH 600V NEMA 3R 20A/3P 20A -

DS-200-EF-SPD-D FUSED DISCONNECT SWITCH 600V NEMA 3R 20A/3P 20A -

DS-CU-1 FUSED DISCONNECT SWITCH 240V NEMA 3R 30A/2P 30A -

DS-RO-1 FUSED DISCONNECT SWITCH 600V NEMA 4X 30A/3P 30A 316 STAINLESS STEEL

DS-RO-2 FUSED DISCONNECT SWITCH 600V NEMA 4X 30A/3P 30A 316 STAINLESS STEEL

DS-RP-2 NON-FUSED DISCONNECT SWITCH 600V NEMA 3R 20A/3P 20A -

N/A TOGGLE SWITCH WITH PILOT LIGHT 240V NEMA 3R 20A/1P - -

TS-200-CHWP-1 TOGGLE SWITCH WITH PILOT LIGHT 240V NEMA 3R 20A/3P - -

TS-200-CHWP-2 TOGGLE SWITCH WITH PILOT LIGHT 240V NEMA 3R 20A/3P - -

TS-200-CSG-SPD TOGGLE SWITCH WITH PILOT LIGHT 240V NEMA 3R 20A/1P - -

TS-CUH-1 TOGGLE SWITCH WITH PILOT LIGHT 240V NEMA 3R 20A/1P - -

TS-P-3 TOGGLE SWITCH WITH PILOT LIGHT 120V NEMA 1 20A/1P - SWITCH SHALL BE HORSEPOWER RATED.

TS-RP-1 TOGGLE SWITCH WITH PILOT LIGHT 120V NEMA 3R 20A/1P - SWITCH SHALL BE HORSEPOWER RATED.

TS-TP-1 TOGGLE SWITCH WITH PILOT LIGHT 120V NEMA 1 20A/1P - SWITCH SHALL BE HORSEPOWER RATED.

CODED NOTES:

EXISTING BUILDING 7 TRANSFORMER IS A LOOP FEED TRANSFORMER USED AS A RADIAL FEED

TRANSFORMER WITH DEADFRONT ARRESTERS ON THE 'HV B' TERMINALS. DEADBREAK ARRESTERS SHALL BE DISCONNECTED, AND NEW EQUIPMENT SHALL BE FED FROM THE 'HV B' SIDE OF THE TRANSFORMER. COORDINATE ANY DOWNTIME WITH THE VA AND ACQUIRE ALL APPROPRIATE WORK PERMITS PRIOR TO CONSTRUCTION. PROVIDE A SIDE BOX TO PULL THE FEEDERS THROUGH AND DOWN INTO THE UNDERGROUND CONDUITS. COORDINATE ALL LOCATIONS AND CONNECTIONS WITH THE VA, CIVIL, AND STRUCTURAL DRAWINGS PRIOR TO CONSTRUCTION.

DUE TO PART AVAILABILITY AND END-OF-LIFE CONSIDERATIONS, THIS PANEL WILL BE REMOVED AND REPLACED WITH A NEW PANELBOARD. COORDINATE ANY POWER OUTAGES WITH THE VA (4) WEEKS IN

ADVANCE.

Revisions Date

1 ADDENDUM 1 09/03/2025

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120

FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

VA Project No.

AG Project No.

A u to d e s k D o c s

/0

N o rt h p o rt

S P

S /0

N o rt h p o rt

S P

S

R

M E

P F

P F

A T

.r v t

/2

/2

:3

:0

P

M

E-801

ELECTRICAL SCHEDULES RENOVATE STERILE

PROCESSING DEPARTMENT,

BUILDING NO. 200

NORTHPORT VA

0123025

06/18/2025 CJM IMW

100% CONSTRUCTION

DOCUMENTS

632-12-106

Notes:

Total Est. Demand Current: 464 A

SPS Equipment 466685 VA 75.00% 350014 VA Total Conn. Current: 604 A

Receptacle 1800 VA 100.00% 1800 VA Total Est. Demand: 385705 VA

Other 33635 VA 100.00% 33635 VA Total Conn. Load: 502377 VA

Lighting 257 VA 100.00% 257 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

604 A

502377 VA

10 SPARE 1 20 A 0.0 kVA

9 HEAT TRACE 1 20 A 6.6 kVA

8 HEAT TRACE 1 30 A 6.6 kVA

7 HEAT TRACE 1 30 A 6.6 kVA

6 HEAT TRACE 1 30 A 6.6 kVA

5 SITE LIGHTING 1 20 A 0.3 kVA

4 LIGHTING - TRAILER CORRIDOR 1 20 A 0.3 kVA

3 MSSU-CWP 3 15 A 10.0 kVA

2 MDPU 3 600 A 399.1 kVA

1 PANEL LTPS VIA T-LTPS 3 400 A 66.2 kVA

CKT Circuit Description # of

Poles Trip Rating Load Remarks

NEW NEMA 3R, EXTERIOR RATED 480/277V NORMAL POWER PANELBOARD.

Notes:

Neutral Rating: 100.00%

Enclosure: NEMA 1 MCB Rating: 800 A

Mounting: Surface Wires: 4 Mains Rating: 800 A

Supply From: ATS-SPS Phases: 3 Mains Type: MCB

Location: EXTERIOR Volts: 480/277 Wye A.I.C. Rating: 65,000

Panelboard: HTPS

BRANCH CIRCUIT NOTES:

TOTAL EST. DEMAND... 144 A

TOTAL CONNECTED... 184 A

SPS Equipment 57644 VA 75.00% 43233 VA TOTAL EST. DEMAND: 51824 VA

Receptacle 1800 VA 100.00% 1800 VA TOTAL CONNECTED LOAD: 66234 VA

Other 6791 VA 100.00% 6791 VA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS

LEGEND:

TOTAL... 211 A 182 A 164 A

TOTAL... 25005 VA 21585 VA 19645 VA

23 SPACE -- 1 -- -- 1 -- SPACE 24

21 SPACE -- 1 -- -- 1 -- SPACE 22

19 SPACE -- 1 -- -- 1 -- SPACE 20

17 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 18

15 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 16

13 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 14

11 RECEPT - EQUIPMENT SUPPORT 20 A 1 180 VA 200 VA 1 20 A JBOX - MODs 12

9 RECEPT - TRAILER EXTERIOR 20 A 1 540 VA 0 VA 1 20 A V-1504 LIFT 10

7 RECEPT - TRAILER CORRIDOR 20 A 1 1080... 2880... 1 30 A M-1504 LIFT 8

5 1921... 50 VA 1 20 A LIGHTING - EQUIPMENT SUPPORT 6

3 1921... 1830... 4

MSSU 200 A 3

1921... 1830...

2 30 A AC-1 / CU-1

CKT CIRCUIT DESCRIPTION

NOTE

S TRIP POLES A B C POLES TRIP

NOTE

S CIRCUIT DESCRIPTION CKT

NEW NEMA 3R, EXTERIOR RATED 208/120V NORMAL POWER PANELBOARD.

GENERAL NOTES:

ENCLOSURE: Type 1 SERVICE ENTRANCE: NO

MOUNTING: Surface WIRES: 4 MAINS RATING: 400 A

SUPPLY FROM: T-LTPS PHASES: 3 MAINS TYPE: MCB

LOCATION: COURTYARD VOLTS: 120/208 Wye A.I.C. RATING: 10,000

BRANCH PANEL: LTPS

1. EXISTING CIRCUIT OR SPARE/SPACE TO REMAIN.

2. EXISTING SPARE TO BE UTILIZED FOR NEW CIRCUIT.

BRANCH CIRCUIT NOTES:

TOTAL EST. DEMAND... 1 A

TOTAL CONNECTED... 1 A

TOTAL EST. DEMAND: 804 VA

TOTAL CONNECTED LOAD: 804 VA

Lighting 804 VA 100.00% 804 VA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS

LEGEND:

TOTAL... 2 A 0 A 1 A

TOTAL... 464 VA 0 VA 340 VA

29 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 30

27 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 28

25 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 26

23 SPARE 20 A 1 0 VA 0 VA 1 20 A SPARE 24

21 LIGHTING: 1ST FLOOR CORRIDOR 1 20 A 1 0 VA 0 VA 1 20 A 1 LIGHTING: 4TH FLOOR CORRIDOR 22

19 LIGHTING: BASEMENT CORRIDOR 1 20 A 1 0 VA 0 VA 1 20 A 1 LIGHTING: 3RD FLOOR CORRIDOR 20

17 SPARE 1 20 A 1 0 VA 0 VA 1 20 A 1 LIGHTING: 2ND FLOOR CORRIDOR 18

15 -- -- 16

13 -- -- 14

LOWER SECTION CONTROL -- 3

3 -- LOWER SECTION CONTROL

9 LIGHTING: 4TH FLOOR CORRIDOR 1 20 A 1 0 VA -- 1 -- 1 SPACE 10

7 LIGHTING: 3RD FLOOR CORRIDOR 1 20 A 1 0 VA 464 VA 1 20 A 2 LIGHTING - SPS 8

5 LIGHTING: 2ND FLOOR CORRIDOR 1 20 A 1 0 VA 340 VA 1 20 A 2 LIGHTING - OFFICES 6

3 LIGHTING: 1ST FLOOR CORRIDOR 1 20 A 1 0 VA 0 VA 1 20 A 1 LIGHTING: STAIR #1 4

1 LIGHTING: BASEMENT CORRIDOR 1 20 A 1 0 VA 0 VA 1 20 A 1 LIGHTING: EXIT 2

CKT CIRCUIT DESCRIPTION

NOTE

S TRIP POLES A B C POLES TRIP

NOTE

S CIRCUIT DESCRIPTION CKT

EXISTING PARK METAL PROD. CO. CTL 480/277V LIFE SAFETY PANELBOARD. THIS PANEL WILL BE REPLACED WITH A NEW PANELBOARD AS PART OF THIS PROJECT.

LOADS SHOWN REFLECT THE AMOUNT OF NEW LOAD BEING ADDED TO THE PANEL.

GENERAL NOTES:

ENCLOSURE: Type 1 SERVICE ENTRANCE: NO

MOUNTING: Surface WIRES: 4 MAINS RATING: 100 A

SUPPLY FROM: EM SWBD PHASES: 3 MAINS TYPE: MCB

LOCATION: ELEC. CLOSET C1-1 VOLTS: 480/277 Wye A.I.C. RATING: 14,000

BRANCH PANEL: EH1-C

Revisions Date

1 ADDENDUM 1 09/03/2025

Sheets
E-001 - ELECTRICAL LEGENDS & SYMBOLS
E-002 - ELECTRICAL GENERAL NOTES
E-100 - ELECTRICAL OVERALL GROUND FLOOR PLAN
E-401 - ELECTRICAL ENLARGED PLANS
E-501 - ELECTRICAL DETAILS
E-601 - ELECTRICAL DIAGRAMS
E-801 - ELECTRICAL SCHEDULES
E-802 - ELECTRICAL SCHEDULES
E-803 - ELECTRICAL SCHEDULES
ED101 - ELECTRICAL FIRST FLOOR PLAN - DEMO
EL101 - ELECTRICAL FIRST FLOOR PLAN - LIGHTING NEW WORK
EL102 - ELECTRICAL SECOND FLOOR PLAN - LIGHTING NEW WORK
EP100 - ELECTRICAL BASEMENT FLOOR PLAN - POWER NEW WORK
EP101 - ELECTRICAL FIRST FLOOR PLAN - POWER NEW WORK
EP102 - ELECTRICAL SECOND & FIFTH FLOOR PLAN - POWER NEW WORK

File details come from the government source that posted it. Updated .