About this file

This is a Fire Protection and Suppression specification document issued by the USDA Forest Service Pacific Northwest Region (form R6-FS-6300-52, dated 5/97, with an addendum form R6-FS-6300-54, dated 5/89) that outlines mandatory fire prevention and suppression requirements for contractors, permittees, licensees, and purchasers operating on National Forest land. The fire prevention period runs from April 1 to October 31 annually, with dates subject to modification by the Forest Service based on weather conditions. Before commencing operations, contractors must develop a fire plan in cooperation with the Contracting Officer addressing prevention and control measures specific to the project area, and must certify compliance with these requirements before beginning work during the fire period and whenever operations change. The Contracting Officer retains authority to authorize substitute measures or waive requirements during low fire danger periods and may mandate emergency operational shutdowns during fire emergencies.

Contractors must independently and cooperatively prevent and suppress fires in the project area, with all personnel and equipment available for prompt initial attack. When fighting fires not caused by contractor operations, the contractor must make employees and equipment temporarily available to the Forest Service, with employees compensated under the Inter-agency Pay Plan for Emergency Firefighters and equipment rented at standard area rates or pre-agreed rates. Specific requirements include: preparing a fire plan; maintaining fire tools in a red, marked toolbox containing minimum specified equipment (axes, hoes, shovels); equipping all power-driven equipment with fire extinguishers and hand tools; maintaining spark arresters and mufflers on internal combustion engines; designating a fire security person when Industrial Fire Precaution Levels reach "I" or higher; providing two-way communication capability to report fires within 15 minutes; and restricting operations according to Industrial Fire Precaution Levels (I through IV) that limit activities such as power saw operation, cable yarding, and blasting based on fire danger conditions. Contractors must obtain daily IFPL predictions from the Ranger District headquarters and comply with all state forest fire laws; the IFPL system does not apply on Oregon Department of Forestry-protected lands east of the Cascade Summit.

View the file

Other files for this federal contract opportunity

Other files attached to Malheur NF Tree Planting, newest first.
File Type Posted
1240BK26R0003 Amendment 0001.pdf PDF
1240BK26R0003 Amendment 0001.pdf PDF
Attachment 2_PWS_MalheurTreePlanting_Rev.2_3.18.2026.pdf PDF
Attachment 11_ Map HC Vicinity.pdf PDF
Attachment 16_Map Rail Ridge 2026 Planting Unit_18.pdf PDF
Attachment 20_Map Rail Ridge 2026 Planting Unit_38.pdf PDF
Attachment 23_Map Rail Ridge 2026 Planting Unit_44.pdf PDF
Attachment 39_Map Rail Ridge 2026 Planting Unit_86.pdf PDF
Attachment 40_Map Rail Ridge 2026 Tree Planting Overview Map.pdf PDF
Attachment 42_Map Sand Planting_Unit 10.pdf PDF
Attachment 51_ Map Saw3.pdf PDF
Attachment 58_ Map SawVicinity.pdf PDF
Attachment 59_ Map YJ3.pdf PDF
Attachment 61_DUIS_BMRD_Sand and Rail Ridge_FY26 Malheur Tree Planting_Rev.1_2.11.2026.xlsx XLSX spreadsheet
Attachment 63_Exhibit_A_Government_Quality_Assurance_Plan.pdf PDF
Attachment 64_Exhibit_B_Natural_Objects_for_Shade_Micrositing.pdf PDF
Attachment 65_Exhibit_D_D-1_Hoedad_Shovel_Planting.pdf PDF
Attachment 66_Exhibit_G_Bareroot_Placement.pdf PDF
Attachment 67_Exhibit_H_Bareroot_Seedling_Root_Measurment.pdf PDF
Attachment 2_PWS_FY26MalheurTreePlantingContract_Rev.1_2.11.2026.pdf PDF
Attachment 3_ Map EmiC1.pdf PDF
Attachment 5_Map EmiC3.pdf PDF
Attachment 18_Map Rail Ridge 2026 Planting Unit_22.pdf PDF
Attachment 21_Map Rail Ridge 2026 Planting Unit_40.pdf PDF
Attachment 24_Map Rail Ridge 2026 Planting Unit_46.pdf PDF
Attachment 28_Map Rail Ridge 2026 Planting Unit_58.pdf PDF
Attachment 29_Map Rail Ridge 2026 Planting Unit_60.pdf PDF
Attachment 36_Map Rail Ridge 2026 Planting Unit_78.pdf PDF
Attachment 37_Map Rail Ridge 2026 Planting Unit_82.pdf PDF
Attachment 43_Map Sand Planting_Unit 12.pdf PDF
Attachment 46_Map Sand Planting_Unit 18.pdf PDF
Attachment 52_ Map Saw4.pdf PDF
Attachment 53_ Map Saw5.pdf PDF
Attachment 54_ Map Saw6.pdf PDF
Attachment 55_ Map Saw7.pdf PDF
Attachment 62_DUIS_ECRD_EmiC_HC_Saw_YJ_FY26 Malheur Tree Planting_Rev.1_2.11.2026.xlsx XLSX spreadsheet
Attachment 69_Exhibit_K_Plot Radius and Frequency.pdf PDF
Attachment 72_Exhibit_P_Site_Preparation_Scalping.pdf PDF
Attachment 1_Schedule of Items FY26 Malheur NF Tree Planting.pdf PDF
Attachment 4_ Map EmiC2.pdf PDF
Attachment 6_Map EmiC4.pdf PDF
Attachment 7_ Map EmiC Vicinity.pdf PDF
Attachment 8_Map HC1.pdf PDF
Attachment 9_Map HC2.pdf PDF
Attachment 12_ Map Rail Ridge 2026 Planting Access North.pdf PDF
Attachment 14_Map Rail Ridge 2026 Planting Unit_10.pdf PDF
Attachment 25_Map Rail Ridge 2026 Planting Unit_48.pdf PDF
Attachment 26_Map Rail Ridge 2026 Planting Unit_50.pdf PDF
Attachment 30_Map Rail Ridge 2026 Planting Unit_62.pdf PDF
Attachment 31_Map Rail Ridge 2026 Planting Unit_66.pdf PDF
Show all 50

Malheur NF Tree Planting has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R6-FS-6300-52 (5/97)

USDA FOREST SERVICE

PACIFIC NORTHWEST REGION

FIRE PROTECTION AND SUPPRESSION

1. Fire Period and Closed Season Specific fire prevention measures are listed below and shall be effective for the period April 1 to October 31 of each year. The Forest Service may change the dates of said period by advance written notice if justified by unusual weather or other conditions. Required tools and equipment shall be kept currently in serviceable condition and immediately available for initial attack on fires.

2. Fire Plan Before starting any operations on the project, the Contractor, Permittee, Licensee, or Purchaser, hereinafter referred to as the "Contractor," shall prepare a fire plan in cooperation with the Contracting Officer providing for the prevention and control of fires in the project area.

The Contractor shall certify compliance with fire protection and suppression requirements before beginning operations during the fire period and closed season, and shall update such certification when operations change.

3. Substitute Measures The Contracting Officer may by written notice authorize substitute measures or equipment or may waive specific requirements during periods of low fire danger.

4. Emergency Measures The Forest Service may require emergency measures, including the necessary shutting down of equipment or portions of operations in the project area during periods of fire emergency created by hazardous climatic conditions.

5. Fire Control The Contractor shall, independently and in cooperation with the Forest Service, take all reasonable action to prevent and suppress fires in the project area. Independent initial action shall be prompt and shall include the use of all personnel and equipment available in the project area.

For the purpose of fighting forest fires on or in the vicinity of the project which are not caused by the Contractor's operations, the Contractor shall place employees and equipment temporarily at the disposal of the Forest Service. Any individual hired by the Forest Service will be employed in accordance with the Inter-agency Pay Plan for Emergency Firefighters.

The Forest Service will compensate the Contractor for equipment rented at fire fighting equipment rates common in the area, or at prior agreed to rates.

6. Compliance with State Forest Laws Listing of specific fire precautionary measures herein is not intended to relieve the Contractor in any way from compliance with the State Fire Laws covering fire prevention and suppression equipment, applicable to operations under this contract, permit or license.

7. Fire Precautions

Specific fire precautionary measures are as follows:

a. Smoking and Open Fires Smoking and fires shall be permitted only at the option of the Contractor. The Contractor shall not allow open fires on the project area without advance permission in writing from Forest Service. Unless restricted by State Law or Federal Regulation, smoking shall be permitted only in such portions of the project area that are free of flammable material. Smokers shall sit down to smoke in such a position that any burning material will fall within a cleared area, and shall extinguish and press out in mineral soil all burning material before leaving the cleared area.

b. Fire Extinguishers and Equipment on Trucks, Tractors, etc.

All power-driven equipment operated by the Contractor on National Forest land, except portable fire pumps, shall be equipped with one fire extinguisher having a UL rating of at least 5 BC, and one "D" handled or long handled round point shovel, size "0" or larger. In addition, each motor patrol, truck and passenger-carrying vehicle shall be equipped with a double-bit axe or Pulaski, 3-1/2 pounds or larger.

Equipment shall be kept in a serviceable condition and shall be readily available.

c. Power Saws Each gasoline power saw operator shall be equipped with a pressurized chemical fire extinguisher of not less than 8-ounce capacity by weight, and one long-handled round point shovel, size "0" or larger. The extinguisher shall be kept in possession of the saw operator at all times. The shovel shall be accessible to the operator within 1 minute.

d. Extinguishers One refill for each type or one extra extinguisher sufficient to replace each size extinguisher required on equipment shall be safely stored in the fire tool box or other agreed upon place on the project area that is protected and readily available.

(1) Equipped with a turbine-driven exhaust supercharger such as the turbocharger.

There shall be no exhaust bypass

(2) A passenger-carrying vehicle or light truck, or medium truck up to 40,000 GVW, used on roads and equipped with a factory-designedmuffler complete with baffles and an exhaust system in good working condition.

(3) A heavy duty truck, such as a dump or log truck, or other vehicleused for commercial hauling, used only on roads and equipped with a factory designed muffler and with a vertical stack exhaust system extending above the cab. Exhaust equipment described in this subsection, including spark arresters and mufflers, shall be properly installed and constantly maintained in serviceable condition.

f. Emergency Fire Precautions

The Contractor shall restrict operations in accordance with the Industrial Fire Precaution Levels listed below. The Forest Service may change the Industrial Fire Precaution Levels to other values upon revision of the National Fire Danger Rating System and may change the specific Industrial Fire Precaution Levels when such changes are necessary for the protection of the National Forest. When sent to the Contractor, the revised Industrial Fire Precaution Levels will supersede the attached levels

e. Spark Arresters and Mufflers

Each internal combustion engine shall be equipped with a spark arrester meeting either

(1) USDA Forest Service Standard 5100-1a, or (2) appropriate Society of Automotive Engineers (SAE) recommended practice J335(b) and J350(a) as now or hereafter amended unless it is:

INDUSTRIAL FIRE PRECAUTIONS SCHEDULE

INDUSTRIAL FIRE PRECAUTION (IFPL)

LEVEL

I. Closed season - Fire precaution requirements are in effect. A fire watch/security is required at this and all higher levels unless otherwise waived.

II. Partial hootowl - The following may operate only between the hours of 8 p.m. and 1 p.m., local time:

a. power saws, except at loading sites;

b. cable yarding;

c. blasting;

d. welding or cutting of metal.

III. Partial shutdown - The following shall be prohibited except as indicated:

Cable yarding - except that gravity operated logging systems employing non-motorized carriages may be operated between the hours of 8 p.m. and 1 p.m., local time, when all block and moving lines, except the line between the carriage and the chokers, are suspended 10 feet above the ground;

Power saws - except power saws may be used at loading sites and on tractor/skidder operations between the hours of 8 p.m. and 1 p.m., local time.

In addition, the following are permitted between the hours of 8 p.m. and 1 p.m., local time:

a. tractor/skidder operations;

b. mechanized loading and hauling of any product or material;

c. blasting;

d. welding or cutting of metal;

e. any other spark-emitting operation not specifically mentioned.

IV. General shutdown - All operations are prohibited.

The following definitions shall apply to these Industrial Fire Precaution Levels:

Cable yarding systems: A yarding system employing cables and winches in a fixed position.

Closed season (Fire Precautionary Period): That season of the year when a fire hazard exists as declared by the responsible agency official.

Contracting Officer: The person executing the contract, permit or license on behalf of the Government and includes that person's designated representative, acting within the limits of their authority or the duly appointed successor to the individuals.

Loading sites/woods site/project area: A place where any product or material (including but not limited to logs, firewood, slash, soil, rock, poles, posts, etc.) is placed in or upon a truck or other vehicle

Low hazard area: Means any area where the responsible agency representative (WDNR, ORF, BIA, BLM) determines the combination of elements reduces the probability of fire starting and/or spreading.

Tractor/skidder operations: include a harvesting operation, or portion of a harvesting operation, where tractors, skidders, or other harvesting equipment capable of constructing fireline, are actively yarding forest products and can quickly reach and effectively attack a fire start.

Waivers, written in advance, may be used for any and all activities. Activities for which waivers may be issued include, but are not limited to:

a. mechanized loading and hauling;

b. road maintenance such as sprinkling, graveling, grading and paving;

c. cable yarding using gravity systems or suspended lines and blocks, or other yarding systems where extra prevention measures will significantly reduce the risk of fire;

d. powers saws at loading sites or in felling and bucking where extra prevention measures will significantly reduce the risk of fire;

e. maintenance of equipment (other than metal cutting and welding) or improvements such as structures, fences and powerlines.

Such waiver, or substitute precautions will prescribe measures to be taken by the Contractor to reduce the risk of ignition, and/or the spread of fire. The Contracting Officer shall consider site specific weather factors, fuel conditions, and specific operations that result in less risk of fire ignition and/or spread than contemplated when precaution level was predicted.

Consideration shall also be given to measures that reduce the precaution levels above. The Contractor shall assure that all conditions of such waivers or substitute precautions are met.

The Contractor shall obtain the predicted Industrial Fire Precaution Level daily, prior to the start of work, from the appropriate Ranger District headquarters. If predictions made after 6:00 p.m., local time, are significantly different than the original prediction, the Forest Service will inform the Contractor when changes in restrictions or industrial precautions are made.

The IFPL system does not apply on lands protected by ODF east of the summit of the Cascades.

NOTE:

Where hauling involves transit through more than one shutdown/regulated use area, the precaution level at the woods loading site shall govern the level of haul restriction, unless otherwise prohibited by other than industrial precaution level system.

8. Fire Tools The Contractor shall furnish serviceable fire fighting tools in a readily accessible fire tool box or compartment of sound construction with a hinged lid and hasp so arranged that the box can be secured or sealed. The box shall be red and marked "Fire Tools" in letters one inch high. It shall contain a minimum of:

a. 2 axes or Pulaskis with a 32-inch handle;

b. 3 adze eye hoes. One Pulaski may be substituted for 1 adze eye hoe;

c. 3 long-handled, round point shovels, size "0" or larger.

9. Fire Security When the Industrial Fire Precautions Level is "I" or higher, unless a waiver is granted, the Contractor shall designate a person who shall perform fire security services listed below on the project area and vicinity. The designated person shall be capable of operating the Contractor's communications and fire fighting equipment specified in the contract, excluding helicopters, and of directing the activities of the Contractor's personnel on forest fires. In lieu of having the designated person perform the required supervisory duties, the Contractor may provide another person meeting the qualifications stated above to direct the activities of Contractor's personnel and equipment during all fire fighting activities.

Services described shall be for at least 1 hour from the time the Contractor's operations are shut down. For the purposes of this provision, personnel servicing equipment, and their vehicles, who are not engaged in cutting or welding metal are excluded.

Fire security services shall consist of moving throughout the operation area or areas constantly looking, reporting, and taking suppression action on any fires detected. Where possible, the designated person shall observe inaccessible portions of helicopter operating areas from vantage points within or adjacent to project area.

10. Blasting

Whenever the Industrial Fire Precaution Level is "II" or greater, a fire security person equipped with a long-handled, round point, No. "0" or larger, shovel, and a five-gallon backpack pump can filled with water will stay at location of blast for 1 hour after blasting is done. Blasting may be suspended by Forest Service in writing, in an area of high rate of spread and resistance to control.

Fuses shall not be used for blasting. Explosive cords shall not be used without written permission of Forest Service, which may specify conditions under which such explosives may be used and precautions to be taken.

R6-FS-6300-54 (5/89)

USDA FOREST SERVICE

PACIFIC NORTHWEST REGION

FIRE PROTECTION AND SUPPRESSION

The contractor shall provide adequate two-way communication facilities to report a fire to Forest Service within 15 minutes of detection. FCC Regulations prohibit commercial use of Citizen Band (CB) radios. (CB's are not considered adequate two-way communications).

Such communications shall be operable during periods of operation of power-driven equipment, including the time fire security is required. Fire Period and Closed Season

12. Additional Fire Precationary Measure 2 - Communications