This file contains architectural design documents for a factory-built crew quarters building prototype with a 10-room configuration, intended for fire response crew team members. The comprehensive design package includes detailed floor plans, exterior elevations, building sections, and 3D visualizations showing the complete structure.

The prototype building features a linear layout with multiple functional zones, including a central living and dining area, a kitchen with pantry, mechanical and laundry rooms, a mudroom, communications room, and two wings of bedrooms. The bedroom wings include both ADA-accessible and standard rooms, with single-occupancy bathrooms positioned between bedroom clusters. The building is designed with exterior covered patios, standardized room dimensions, and appears to be a prefabricated modular structure with a tan and dark gray color scheme. The total building length is approximately 65 feet, with careful attention to accessibility, functionality, and crew living requirements.

View the file

Other files for this federal contract opportunity

Other files attached to Orovada Fire Engine Cover & Crew Quarters, NV, newest first.
File Type Posted
Attachment_17_-_SV_Sign-In-Sheet_Orovada_0002.pdf PDF
Attachment_16_-_Sol_Q_A_140L0625R0006_0002.pdf PDF
Sol_140L0625R0006_Amd_0002.pdf PDF
Attachment_15_-_Past_Performance_Questionnaire_-_Revised_0002.docx DOCX document
Attachment_14_-_BLM_Orovada_Fire_Station_Design_BP2_-_Reference_Planset_0001.pdf PDF
Attachment_13_-_BLM_Orovada_Fire_Station_Design_BP1_-_Reference_Planset_0001.pdf PDF
Sol_140L0625R0006_Amd_0001.pdf PDF
Attachment_3_-_SOW__REVISED_Orovada_General-Site_0001.pdf PDF
Attachment_10_-_Orovada_Letters.pdf PDF
Attachment_1_-_SOW_Orovada_Fire_Station_Building_2025-03-11.pdf PDF
Attachment_2_-_SOW_Orovada_Crew_Quarters_2025-03-11.pdf PDF
Attachment_3_-_SOW_Orovada_General-Site_2025-03-11.pdf PDF
Attachment_5_-_OWFS_Performance_Specs_2025-03-14.pdf PDF
Attachment_6_-_Orovada_WFC_Room_Requirements_FSB_2025-01-16.pdf PDF
Attachment_8_-_Orovada_Fire_Station_Reports_and_Feasibility_Study.pdf PDF
Attachment_9_-_Orovada_WFC_Sustainable_Doc_2025-03-13.pdf PDF
Attachment_11_-_Past_Performance_Questionnaire.docx DOCX document
Attachment_12_-_SF1442_Instructions_P1.pdf PDF
Sol_140L0625R0006.pdf PDF
Attachment_4_-_Orovada_Plans_2025-03-10.pdf PDF
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VICINITY MAPSTATE REFERENCE MAP

G

N

ARETNILAN

I T A

ENCY FIR

e

E hB si0 , adI 0

RE

T

CEN

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

NATIONAL SYSTEM OF PUBLIC LANDS

PROTOTYPICAL COVER SHEETCREW QUARTERS BUILDING: FACTORY BUILT PROTOTYPE - 10 ROOM 11.27.2024

CREW QUARTERS BUILDING:

FACTORY BUILT - 10 ROOMS

BUILDING PROGRAM

LIVING, DINING, AND SLEEPING QUARTERS FOR UP TO TEN (1O) FIRE RESPONSE CREW TEAM MEMBERS

TOTAL GROSS BUILDING AREA

3,465 SQUARE FEET

SHEET INDEX

COVER SHEET

OVERALL FLOOR PLAN

LIVING WING PLAN

SLEEPING WING PLAN

ELEVATIONS

BEDROOM BEDROOM BEDROOM BEDROOMABA BEDROOM

SINGLE

OCCUPANCY

BATHING

ROOM

SINGLE

OCCUPANCY

BATHING

ROOM

SINGLE

OCCUPANCY

BATHING

ROOM

SINGLE

OCCUPANCY

BATHING

ROOM ABA BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM

125' - 2"

LIVING AREA

COMMUNICATIONS

ROOM

MUDROOM

PANTRYKITCHEN

DINING

CORRIDOR

EXTERIOR

COVERED

PATIO

EXTERIOR

COVERED

PATIO

LAUNDRY

ROOM

MECHANICAL

ROOM

JANITORIAL

SD202 3

SD202

SD2022

SD202

SIDE

SIDE

ENTRY/FRONT

REAR

G

N

ARETNILAN

I T A

ENCY FIR

e

E hB si0 , adI 0

RE

T

CEN

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

NATIONAL SYSTEM OF PUBLIC LANDS

PROTOTYPICAL OVERALL FLOORPLANCREW QUARTERS BUILDING: FACTORY BUILT PROTOTYPE - 10 ROOM 11.27.2024

2' - 8" 10' - 8"

5' - 4" 21' - 4"

22' - 8" 9' - 10" 18' - 0" 9' - 6"

60' - 0"

47' - 3" 6' - 7 3/4" 6' - 1 1/4"

FUTURE

UPRIGHT

FREEZER OR

FRIDGE

10 STACKED

LOCKERS

(2) REFRIGERATOR WITH

DOOR ICE / WATER

MICROWAVE

OVER THE

ADA RANGE

SINGLE HEIGHT ISLAND

BACKING FOR WALL

MOUNTED TV

CABINETS ON

BOTH SIDES

(2) DISHWASHERS

ADJACENT

MODULE

ADJACENT

MODULE

PANTRY

MUDROOM

LIVING AREA

KITCHEN

DINING

COMMUNICATIONS

ROOM

HALLWAY

COAT

HOOKS

FIRE RISER

JANITORIAL

MECHANICAL ROOM LAUNDRY ROOM

MICROWAVE

OVER THE

ADA RANGE

M

IN

C

LE

AR

T

O F

IN

IS

H 5'

1"

MIN CLEAR TO FINISH

5' - 1"

(1) REFRIGERATOR WITH

DOOR ICE / WATER

ELECTRICAL

PANELS

BACKING FOR WALL

MOUNTED TV

OPTIONAL

LOCATION

FOR

UPRIGHT

FREEZER

G

N

ARETNILAN

I T A

ENCY FIR

e

E hB si0 , adI 0

RE

T

CEN

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

NATIONAL SYSTEM OF PUBLIC LANDS

PROTOTYPICAL LIVING WINGCREW QUARTERS BUILDING: FACTORY BUILT PROTOTYPE - 10 ROOM 11.27.2024

2' - 0" 8' - 0"

4' - 0" 16' - 0"

ADJACENT

MODULE

ADJACENT

MODULE

SITE BUILT

COVERED PATIO

ABA BEDROOM

SINGLE OCCUPANCY

BATHING ROOM

SINGLE OCCUPANCY

BATHING ROOM

SINGLE OCCUPANCY

BATHING ROOM

SINGLE OCCUPANCY

BATHING ROOM

ABA BEDROOM BEDROOM BEDROOM

CORRIDOR

BEDROOM BEDROOM

BEDROOMBEDROOMBEDROOMBEDROOM

8' - 9" 8' - 9" 9' - 10" 9' - 3" 9' - 3" 9' - 3" 9' - 11"

M

IN

C

LE

AR

T

O F

IN

IS

H 5'

1"

M

IN

C

LE

AR

T

O F

IN

IS

H 5'

1"

8' - 9" 8' - 9" 9' - 10" 9' - 3" 9' - 3" 9' - 3" 9' - 11"

65' - 0"

M

IN

T O

F R

AM

IN

G 4'

6"

SD.201

SD.201

G

N

ARETNILAN

I T A

ENCY FIR

e

E hB si0 , adI 0

RE

T

CEN

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

NATIONAL SYSTEM OF PUBLIC LANDS

PROTOTYPICAL SLEEPING WINGCREW QUARTERS BUILDING: FACTORY BUILT PROTOTYPE - 10 ROOM 11.27.2024

1' - 4" 5' - 4"

2' - 8" 10' - 8"

1' - 0"

GAPS ARE REPRESENTATION OF

POTENTIAL MODULEAR BREAK,

TRIM PIECE WILL BE REQUIRED

LIGHTER NATURAL

PAINT COLORS

GAPS REFLECT

MODULE BREAK,

TRIM PIECE WILL

BE REQUIRED

WINDOWS THROUGHTOUT

TO BE SAME SIZE, EXCEPT

IN BATHROOMS.

8'

0" M

IN

IM

U M

G

N

ARETNILAN

I T A

ENCY FIR

e

E hB si0 , adI 0

RE

T

CEN

U.S. DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

NATIONAL SYSTEM OF PUBLIC LANDS

PROTOTYPICAL ELEVATIONSCREW QUARTERS BUILDING: FACTORY BUILT PROTOTYPE - 10 ROOM

11.27.2024

ENTRY / FRONT

SIDE ELEVATIONSIDE ELEVATION

REAR ELEVATION

2' - 0" 8' - 0"

4' - 0" 16' - 0"

2' - 0" 8' - 0"

4' - 0" 16' - 0"

2' - 0" 8' - 0"

4' - 0" 16' - 0"

2' - 0" 8' - 0"

4' - 0" 16' - 0"

BUILDING SECTION

2' - 0" 8' - 0"

4' - 0" 16' - 0"

SD.000 - PROTOTYPICAL COVER SHEET
SD.101 - PROTOTYPICAL OVERALL FLOORPLAN
SD.104 - PROTOTYPICAL LIVING WING
SD.103 - PROTOTYPICAL SLEEPING WING
SD.201 - PROTOTYPICAL ELEVATIONS