This file contains architectural design documents for a factory-built crew quarters building prototype with a 10-room configuration, intended for fire response crew team members. The comprehensive design package includes detailed floor plans, exterior elevations, building sections, and 3D visualizations showing the complete structure.
The prototype building features a linear layout with multiple functional zones, including a central living and dining area, a kitchen with pantry, mechanical and laundry rooms, a mudroom, communications room, and two wings of bedrooms. The bedroom wings include both ADA-accessible and standard rooms, with single-occupancy bathrooms positioned between bedroom clusters. The building is designed with exterior covered patios, standardized room dimensions, and appears to be a prefabricated modular structure with a tan and dark gray color scheme. The total building length is approximately 65 feet, with careful attention to accessibility, functionality, and crew living requirements.
View the file
Other files for this federal contract opportunity
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VICINITY MAPSTATE REFERENCE MAP
G
N
ARETNILAN
I T A
ENCY FIR
e
E hB si0 , adI 0
RE
T
CEN
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
NATIONAL SYSTEM OF PUBLIC LANDS
PROTOTYPICAL COVER SHEETCREW QUARTERS BUILDING: FACTORY BUILT PROTOTYPE - 10 ROOM 11.27.2024
CREW QUARTERS BUILDING:
FACTORY BUILT - 10 ROOMS
BUILDING PROGRAM
LIVING, DINING, AND SLEEPING QUARTERS FOR UP TO TEN (1O) FIRE RESPONSE CREW TEAM MEMBERS
TOTAL GROSS BUILDING AREA
3,465 SQUARE FEET
SHEET INDEX
COVER SHEET
OVERALL FLOOR PLAN
LIVING WING PLAN
SLEEPING WING PLAN
ELEVATIONS
BEDROOM BEDROOM BEDROOM BEDROOMABA BEDROOM
SINGLE
OCCUPANCY
BATHING
ROOM
SINGLE
OCCUPANCY
BATHING
ROOM
SINGLE
OCCUPANCY
BATHING
ROOM
SINGLE
OCCUPANCY
BATHING
ROOM ABA BEDROOM BEDROOM BEDROOM BEDROOM BEDROOM
125' - 2"
LIVING AREA
COMMUNICATIONS
ROOM
MUDROOM
PANTRYKITCHEN
DINING
CORRIDOR
EXTERIOR
COVERED
PATIO
EXTERIOR
COVERED
PATIO
LAUNDRY
ROOM
MECHANICAL
ROOM
JANITORIAL
SD202 3
SD202
SD2022
SD202
SIDE
SIDE
ENTRY/FRONT
REAR
G
N
ARETNILAN
I T A
ENCY FIR
e
E hB si0 , adI 0
RE
T
CEN
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
NATIONAL SYSTEM OF PUBLIC LANDS
PROTOTYPICAL OVERALL FLOORPLANCREW QUARTERS BUILDING: FACTORY BUILT PROTOTYPE - 10 ROOM 11.27.2024
2' - 8" 10' - 8"
5' - 4" 21' - 4"
22' - 8" 9' - 10" 18' - 0" 9' - 6"
60' - 0"
47' - 3" 6' - 7 3/4" 6' - 1 1/4"
FUTURE
UPRIGHT
FREEZER OR
FRIDGE
10 STACKED
LOCKERS
(2) REFRIGERATOR WITH
DOOR ICE / WATER
MICROWAVE
OVER THE
ADA RANGE
SINGLE HEIGHT ISLAND
BACKING FOR WALL
MOUNTED TV
CABINETS ON
BOTH SIDES
(2) DISHWASHERS
ADJACENT
MODULE
ADJACENT
MODULE
PANTRY
MUDROOM
LIVING AREA
KITCHEN
DINING
COMMUNICATIONS
ROOM
HALLWAY
COAT
HOOKS
FIRE RISER
JANITORIAL
MECHANICAL ROOM LAUNDRY ROOM
MICROWAVE
OVER THE
ADA RANGE
M
IN
C
LE
AR
T
O F
IN
IS
H 5'
1"
MIN CLEAR TO FINISH
5' - 1"
(1) REFRIGERATOR WITH
DOOR ICE / WATER
ELECTRICAL
PANELS
BACKING FOR WALL
MOUNTED TV
OPTIONAL
LOCATION
FOR
UPRIGHT
FREEZER
G
N
ARETNILAN
I T A
ENCY FIR
e
E hB si0 , adI 0
RE
T
CEN
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
NATIONAL SYSTEM OF PUBLIC LANDS
PROTOTYPICAL LIVING WINGCREW QUARTERS BUILDING: FACTORY BUILT PROTOTYPE - 10 ROOM 11.27.2024
2' - 0" 8' - 0"
4' - 0" 16' - 0"
ADJACENT
MODULE
ADJACENT
MODULE
SITE BUILT
COVERED PATIO
ABA BEDROOM
SINGLE OCCUPANCY
BATHING ROOM
SINGLE OCCUPANCY
BATHING ROOM
SINGLE OCCUPANCY
BATHING ROOM
SINGLE OCCUPANCY
BATHING ROOM
ABA BEDROOM BEDROOM BEDROOM
CORRIDOR
BEDROOM BEDROOM
BEDROOMBEDROOMBEDROOMBEDROOM
8' - 9" 8' - 9" 9' - 10" 9' - 3" 9' - 3" 9' - 3" 9' - 11"
M
IN
C
LE
AR
T
O F
IN
IS
H 5'
1"
M
IN
C
LE
AR
T
O F
IN
IS
H 5'
1"
8' - 9" 8' - 9" 9' - 10" 9' - 3" 9' - 3" 9' - 3" 9' - 11"
65' - 0"
M
IN
T O
F R
AM
IN
G 4'
6"
SD.201
SD.201
G
N
ARETNILAN
I T A
ENCY FIR
e
E hB si0 , adI 0
RE
T
CEN
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
NATIONAL SYSTEM OF PUBLIC LANDS
PROTOTYPICAL SLEEPING WINGCREW QUARTERS BUILDING: FACTORY BUILT PROTOTYPE - 10 ROOM 11.27.2024
1' - 4" 5' - 4"
2' - 8" 10' - 8"
1' - 0"
GAPS ARE REPRESENTATION OF
POTENTIAL MODULEAR BREAK,
TRIM PIECE WILL BE REQUIRED
LIGHTER NATURAL
PAINT COLORS
GAPS REFLECT
MODULE BREAK,
TRIM PIECE WILL
BE REQUIRED
WINDOWS THROUGHTOUT
TO BE SAME SIZE, EXCEPT
IN BATHROOMS.
8'
0" M
IN
IM
U M
G
N
ARETNILAN
I T A
ENCY FIR
e
E hB si0 , adI 0
RE
T
CEN
U.S. DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
NATIONAL SYSTEM OF PUBLIC LANDS
PROTOTYPICAL ELEVATIONSCREW QUARTERS BUILDING: FACTORY BUILT PROTOTYPE - 10 ROOM
11.27.2024
ENTRY / FRONT
SIDE ELEVATIONSIDE ELEVATION
REAR ELEVATION
2' - 0" 8' - 0"
4' - 0" 16' - 0"
2' - 0" 8' - 0"
4' - 0" 16' - 0"
2' - 0" 8' - 0"
4' - 0" 16' - 0"
2' - 0" 8' - 0"
4' - 0" 16' - 0"
BUILDING SECTION
2' - 0" 8' - 0"
4' - 0" 16' - 0"
| SD.000 - PROTOTYPICAL COVER SHEET |
| SD.101 - PROTOTYPICAL OVERALL FLOORPLAN |
| SD.104 - PROTOTYPICAL LIVING WING |
| SD.103 - PROTOTYPICAL SLEEPING WING |
| SD.201 - PROTOTYPICAL ELEVATIONS |