Attachment 7 - 556-402 SPS 100CD Drawings 29NOV22-r14JUN24 6-8.pdf
PDF 31 MB Posted
- Attached to
- Y1DA--556-402 Expand Sterile Processing Service (SPS) - Construction - Lovell FHCC, North Chicago, IL
- Solicitation number
- 36C77624B0018
About this file
This document appears to be Attachment 7 - 556-402 SPS 100CD Drawings 29NOV22-r14JUN24 6-8.pdf, which is associated with the federal contract opportunity for Solicitation Number 36C77624B0018 "Y1DA--556-402 Expand Sterile Processing Service (SPS) - Construction - Lovell FHCC, North Chicago, IL" issued by the Department of Veterans Affairs Technology Acquisition Center Austin.
The document contains drawings related to the construction project to expand the Sterile Processing Service (SPS) at the Lovell Federal Health Care Center in North Chicago, Illinois. The drawings appear to cover details such as floor plans, equipment layouts, and mechanical systems. No additional details about the required products, services, pricing, or other contract terms are provided in this attachment.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
556-402
11/29/2022
EXPAND STERILE PROCESSING
SERVICE (SPS)
100% CONSTRUCTION
DOCUMENTS
Captain James A. Lovell Federal Healthcare Center 3001 Green Bay Road, North Chicago, IL 60064
Alesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
1070 Howard St Omaha, Nebraska 68102 Phone: (402) 455-7698 incandescence life safety, inc.
3575 Ringsby Ct Unit 408, Denver, CO 80216 Phone: (720) 722-3010
IMEG Corp.
263 Shuman Blvd. Suite 550 Naperville, IL 60563 Phone: (630) 527-2320
Calibre Engineering, Inc.
9090 S Ridgeline Blvd #105, Highlands Ranch, CO 80129 Phone: (303) 730-0434
Force Protect Security Cons.
10901 Front Beach Road, Suite 1415 Panama City Beach, FL 32407
A u to d e s k D o c s /2
-2
-4
V
A E x p a n d S te ri le P ro c e s s in g S e rv ic e s
S P
S
D e s ig n /R
-2
V
A
-4
.r v t
/5
/2
:0
:1
P M
GI001
COVER
MP
133CA
C A P T. J A M E S A. L O V E L L F E D E R A L H E A L T H C A R E C E N T E R
EXPAND STERILE PROCESSING SERVICE (SPS)
NORTH CHICAGO, ILLINOIS, 60064
SITE LOCATION
VA Contract Number: 36C77622C0002
VA Point of Contact:
Daniel J. Lid, D: (224) 610-3567, Contracting Officer's Representative (COR)
Mark Revisions: Date: 07/05/2023 REVISIONS
11/29/2022
REV 6/14/2024
Volume 6 of 8
ISSUED 11/29/2022
SET REV 06/14/2024
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
556-402
11/29/2022
EXPAND STERILE PROCESSING
SERVICE (SPS)
100% CONSTRUCTION
DOCUMENTS
Captain James A. Lovell Federal Healthcare Center 3001 Green Bay Road, North Chicago, IL 60064
Alesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
1070 Howard St Omaha, Nebraska 68102 Phone: (402) 455-7698 incandescence life safety, inc.
3575 Ringsby Ct Unit 408, Denver, CO 80216 Phone: (720) 722-3010
IMEG Corp.
263 Shuman Blvd. Suite 550 Naperville, IL 60563 Phone: (630) 527-2320
Calibre Engineering, Inc.
9090 S Ridgeline Blvd #105, Highlands Ranch, CO 80129 Phone: (303) 730-0434
Force Protect Security Cons.
10901 Front Beach Road, Suite 1415 Panama City Beach, FL 32407
A u to d e s k D o c s /2
-2
-4
V
A E x p a n d S te ri le P ro c e s s in g S e rv ic e s
S P
S
D e s ig n /R
-2
V
A
-4
.r v t
/2
/2
:1
:3
P
M
GI002
INDEX OF DRAWINGS
MP
133CA
INDEX OF DRAWINGS
SHEET
NO. SHEET NAME
GENERAL
GI001 COVER
GI002 INDEX OF DRAWINGS
GI101 PHASING PLANS
GI102 FLOW DIAGRAMS
GI103 BID ALTERNATE 1 & 2
GI104 BID ALTERNATE 3 & 4
LIFE SAFETY
LS000 CODE COMPLIANCE SUMMARY PLAN
LS100 PIPE BASEMENT - LIFE SAFETY PLAN
LS101 BASEMENT FLOOR - LIFE SAFETY PLAN
LS102 FIRST FLOOR - LIFE SAFETY PLAN
LS103 EGRESS PHASING COMPLIANCE PLAN - BASEMENT
HAZARDOUS MATERIALS
HA101 BASEMENT FLOOR PLAN – ASBESTOS ABATEMENT
CIVIL
CD100 DEMOLITION PLAN PHASE 1
SP100 SITE PLAN PHASE 1
CS500 SITE DETAILS PHASE 1
CS501 SITE DETAILS PHASE 1
CG100 GRADING PLAN PHASE 1
CU100 OVERALL UTILITY PLAN PHASE 1
CU101 SANITARY SEWER PLAN & PROFILE PHASE 1
CU104 STORM SEWER PLAN AND PROFILE PHASE 1
CU500 STORM SEWER DETAILS PHASE 1
CU501 STORM SEWER DETAILS PHASE 1
STRUCTURAL
SG001 STRUCTURAL GENERAL NOTES
SD1PB.1 PIPE BASEMENT FLOOR - PARTIAL DEMO PLAN & ELEV - PHASE 1
SD100.1 BASEMENT FLOOR - PARTIAL DEMO PLAN & ELEVATION - PHASE 1
SD100.2 BASEMENT FLOOR - DEMO PLAN & ELEVATION - PHASE 2
SD100.3 BASEMENT FLOOR - PARTIAL DEMO PLAN & ELEV - PHASE 3
SD100.4 BASEMENT FLOOR - PARTIAL DEMO PLAN - PHASE 4
SB1PB.1 PIPE BASEMENT FLOOR - FNDN. & MUD SLAB PLAN - PHASE 1
SB1PB.2 PIPE BASEMENT FLOOR - FOUNDATION & MUD SLAB - PHASE 2
SB301 STRUCTURAL SECTIONS
SB501 FOUNDATION DETAILS & SCHEDULES
SB502 FOUNDATION DETAILS
SF100.1 BASEMENT FLOOR FRAMING PLAN - PHASE 1
SF100.2 BASEMENT FLOOR FRAMING PLAN - PHASE 2
SF100.3 BASEMENT FLOOR - FRAMING PLAN - PHASE 3
SF101.2 FIRST FLOOR - MECHANICAL PENTHOUSE FRAMING PLAN - PHASE 2
SF102.2 SECOND FLOOR - ROOF FRAMING PLAN - PHASE 2
SF401 ELEVATIONS & DETAILS
SF402 STRUCTURAL RETROFIT ELEVATIONS IN BUILDING 133-C
SF501 FRAMING DETAILS
SF502 FRAMING DETAILS
SF503 FRAMING DETAILS
SF504 FRAMING DETAILS
SF510 LIGHT GAGE FRAMING STRUCTURAL DETAILS
SF511 WALL SECTIONS -LIGHT GAGE INFORMATION
SF600 LIVE LOAD DIAGRAM - BASEMENT FLOOR
SF601 LIVE LOAD DIAGRAM - FIRST FLOOR
ARCHITECTURAL
AG001 ARCHITECTURAL ABBREVIATIONS, LEGENDS AND NOTES
AD1PB.2 PIPE BASEMENT FLOOR - DEMOLITION PLAN - PHASE 2
AD100.1 BASEMENT FLOOR - DEMOLITION PLAN - PHASE 1
AD100.2 BASEMENT FLOOR - DEMOLITION PLAN - PHASE 2
AD100.3 BASEMENT FLOOR - DEMOLITION PLAN - PHASE 3
AD100.4 BASEMENT FLOOR - DEMOLITION PLAN - PHASE 4
AD101.2 FIRST FLOOR - DEMOLITION PLAN - PHASE 2
AD102.2 SECOND FLOOR - DEMOLITION PLAN - PHASE 2
AE1PB.2 PIPE BASEMENT FLOOR - FLOOR PLAN - PHASE 2
AE100.1 BASEMENT FLOOR - FLOOR PLAN - PHASE 1
AE100.2 BASEMENT FLOOR - FLOOR PLAN - PHASE 2
AE100.3 BASEMENT FLOOR - FLOOR PLAN - PHASE 3
AE100.4 BASEMENT FLOOR - FLOOR PLAN - PHASE 4
AE101.2 FIRST FLOOR - MECHANICAL PENTHOUSE PLAN - PHASE 2
AE102.2 SECOND FLOOR - ROOF PLAN - PHASE 2
AE110.1 BASEMENT FLOOR - REFLECTED CEILING PLAN - PHASE 1
AE110.2 BASEMENT FLOOR - REFLECTED CEILING PLAN - PHASE 2
AE110.3 BASEMENT FLOOR - REFLECTED CEILING PLAN - PHASE 3
AE110.4 BASEMENT FLOOR - REFLECTED CEILING PLAN - PHASE 4
AE201 EXTERIOR ELEVATIONS
AE301 BUILDING SECTIONS
AE302 WALL SECTIONS
AE303 WALL SECTIONS
AE304 WALL SECTIONS
AE401 ENLARGED PLANS AND ELEVATIONS
AE402 ENLARGED PLANS AND ELEVATIONS
AE501 EXTERIOR DETAILS
AE502 WALL SECTIONS & DETAILS
AE503 EXPANSION JOINT DETAILS
AE504 PLAN DETAILS
AE505 PLAN DETAILS
AE531 CEILING DETAILS
AE601 ROOM PROGRAM SCHEDULE
AE602 DOOR SCHEDULES AND DETAILS
AE801 WALL TYPES
AE901 EXTERIOR RENDERINGS AND INTERIOR 3D VIEWS
AE902 BASEMENT FLOOR - FUNCTIONAL AREA PLAN
INDEX OF DRAWINGS
SHEET
NO. SHEET NAME
INTERIORS
IN100.1 BASEMENT FLOOR - INTERIORS PLAN - PHASE 1
IN100.2 BASEMENT FLOOR - INTERIORS PLAN - PHASE 2
IN100.3 BASEMENT FLOOR - INTERIORS PLAN - PHASE 3
IN100.4 BASEMENT FLOOR - INTERIORS PLAN - PHASE 4
IN100.41 BASEMENT FLOOR - INTERIORS PLAN - PHASE 4 - BID ALTERNATE 1
IN100.42 BASEMENT FLOOR - INTERIORS PLAN - PHASE 4 - BID ALTERNATE 2
IN100.43 BASEMENT FLOOR - INTERIORS PLAN - PHASE 4 - BID ALTERNATE 3
IN100.44 BASEMENT FLOOR - INTERIORS PLAN - PHASE 4 - BID ALTERNATE 4
IN101.2 FIRST FLOOR - INTERIORS PLAN - PHASE 2
IN501 INTERIORS DETAILS
IN601 ROOM FINISH SCHEDULE
IN602 ROOM FINISH SCHEDULE - BID ALTERNATES
IN603 SIGNAGE SCHEDULE
EQUIPMENT
QH100.2C BASEMENT FLOOR - EQUIPMENT PLAN - PHASE 2 AREA C
QH100.2D BASEMENT FLOOR - EQUIPMENT PLAN - PHASE 2 AREA D
QH100.4A BASEMENT FLOOR - EQUIPMENT PLAN - PHASE 4 AREA A
QH100.4B BASEMENT FLOOR - EQUIPMENT PLAN - PHASE 4 AREA B
QH101.2D FIRST FLOOR - EQUIPMENT PLAN - PHASE 2 AREA D
QH601 EQUIPMENT JSN SCHEDULES
FIRE PROTECTION
FA000 FIRE ALARM NOTES AND DETAILS
FA101 BASEMENT - FIRE ALARM PLAN
FA102 FIRST FLOOR - FIRE ALARM PLAN
FX000 FIRE SUPPRESSION NOTES AND DETAILS
FX101 BASEMENT - FIRE SUPPRESSION PLAN
FX102 FIRST FLOOR - FIRE SUPPRESSION PLAN
PLUMBING
P000 PLUMBING COVERSHEET
PD1PB.2 PIPE BASEMENT DEMOLITION - PLUMBING - PHASE 2
PD1PB.4 PIPE BASEMENT DEMOLITION - PLUMBING - PHASE 4
PD100.4 BASEMENT DEMOLITION - PLUMBING - PHASE 4
P1PB.0 PIPE BASEMENT - PLUMBING - ALL PHASES
P1PB.2 PIPE BASEMENT - PLUMBING - PHASE 2
P1PB.3 PIPE BASEMENT - PLUMBING - PHASE 3
P1PB.4 PIPE BASEMENT - PLUMBING - PHASE 4
P1PB.44 PIPE BASEMENT – PLUMBING – PHASE 4 – BID ALTERNATE 4
P100.0 BASEMENT - PLUMBING - ALL PHASES
P100.2 BASEMENT - PLUMBING - PHASE 2
P100.3 BASEMENT - PLUMBING - PHASE 3
P100.4 BASEMENT - PLUMBING - PHASE 4
P100.44 BASEMENT – PLUMBING – PHASE 4 – BID ALTERNATE 4
P101.0 FIRST FLOOR - PLUMBING - ALL PHASES
P101.2 FIRST FLOOR - PLUMBING - PHASE 2
P102.0 SECOND FLOOR - PLUMBING - ALL PHASES
P102.2 SECOND FLOOR - PLUMBING - PHASE 2
P200 PLUMBING ENLARGED PLAN
P300 D.I. WATER FLOW DIAGRAM
P301 PLUMBING SANITARY-VENT RISER DIAGRAM - PHASE 2
P302 PLUMBING DOMESTIC WATER RISER DIAGRAM - PHASE 2
P303 PLUMBING RISER DIAGRAM - PHASE 4
P304 DI WATER RISER DIAGRAM - PHASE 2
P400 PLUMBING DETAILS
P401 PLUMBING DETAILS
P500 PLUMBING SCHEDULES
MECHANICAL
M000 MECHANICAL COVERSHEET
MD2PB.2 PIPE BASEMENT DEMOLITION - PIPING - PHASE 2
MD100.1 BASEMENT DEMOLITION - VENTILATION - PHASE 1
MD100.2 BASEMENT DEMOLITION - VENTILATION - PHASE 2
MD100.3 BASEMENT DEMOLITION - VENTILATION - PHASE 3
MD100.4 BASEMENT DEMOLITION - VENTILATION - PHASE 4
MD101.2 FIRST FLOOR DEMOLITION - VENTILATION - PHASE 2
MD101.4 FIRST FLOOR DEMOLITION - VENTILATION - PHASE 4
MD102.4 SECOND FLOOR DEMOLITION – VENTILATION – PHASE 4
MD103.4 THIRD FLOOR DEMOLITION – VENTILATION – PHASE 4
MD104.4 FOURTH FLOOR DEMOLITION – VENTILATION – PHASE 4
MD200.4 BASEMENT DEMOLITION - PIPING - PHASE 4
M1PB.2 PIPE BASEMENT - VENTILATION - PHASE 2
M2PB.2 PIPE BASEMENT - PIPING - PHASE 2
M100.0 BASEMENT - VENTILATION - ALL PHASES
M100.1 BASEMENT - VENTILATION - PHASE 1
M100.2 BASEMENT - VENTILATION - PHASE 2
M100.3 BASEMENT - VENTILATION - PHASE 3
M100.4 BASEMENT - VENTILATION - PHASE 4
M100.41 BASEMENT – VENTILATION – PHASE 4 - BID ALTERNATE 1
M100.42 BASEMENT – VENTILATION – PHASE 4 - BID ALTERNATE 2
M100.43 BASEMENT – VENTILATION – PHASE 4 - BID ALTERNATE 3
M100.44 BASEMENT – VENTILATION – PHASE 4 - BID ALTERNATE 4
M101.0 FIRST FLOOR - VENTILATION - ALL PHASES
M101.2 FIRST FLOOR - VENTILATION - PHASE 2
M101.4 FIRST FLOOR - VENTILATION - PHASE 4
M102.0 SECOND FLOOR - VENTILATION - ALL PHASES
M102.2 SECOND FLOOR - VENTILATION - PHASE 2
M200.0 BASEMENT - PIPING - ALL PHASES
M200.2 BASEMENT - PIPING - PHASE 2
M200.4 BASEMENT - PIPING - PHASE 4
M200.44 BASEMENT – PIPING – PHASE 4 – BID ALTERNATE 4
M201.0 FIRST FLOOR - PIPING - ALL PHASES
M201.2 FIRST FLOOR - PIPING - PHASE 2
INDEX OF DRAWINGS
SHEET
NO. SHEET NAME
M300 MECHANICAL DETAILS
M301 MECHANICAL DETAILS
M302 MECHANICAL DETAILS
M303 MECHANICAL DETAILS
M304 AHU COMPONENT PLAN
M305 AIRFLOW MAP
M306 AIRFLOW MAP
M307 STEAM FLOW DIAGRAM
M400 MECHANICAL DIAGRAMS
M401 MECHANICAL DIAGRAMS
M402 MECHANICAL DIAGRAMS
M403 MECHANICAL DIAGRAMS
M600 MECHANICAL SCHEDULES
M601 MECHANICAL SCHEDULES
ELECTRICAL
E000 ELECTRICAL COVERSHEET
ED100.1 BASEMENT DEMOLITION - ELECTRICAL- PHASE 1
ED100.2 BASEMENT DEMOLITION - ELECTRICAL - PHASE 2
ED100.3 BASEMENT DEMOLITION - ELECTRICAL - PHASE 3
ED100.4 BASEMENT DEMOLITION - ELECTRICAL - PHASE 4
E1PB.2 SUB BASEMENT - ELECTRICAL - PHASE 2
E100.0 BASEMENT - POWER - ALL PHASES
E100.1 BASEMENT - POWER - PHASE 1
E100.2 BASEMENT - POWER - PHASE 2
E100.3 BASEMENT - POWER - PHASE 3
E100.4 BASEMENT - POWER - PHASE 4
E100.41 BASEMENT - POWER - PHASE 4 - ALTERNATE 1
E100.42 BASEMENT - POWER - PHASE 4 - ALTERNATE 2
E100.43 BASEMENT - POWER - PHASE 4 - ALTERNATE 3
E100.44 BASEMENT - POWER - PHASE 4 - ALTERNATE 4
E101.0 BASEMENT - LIGHTING - ALL PHASES
E101.1 BASEMENT - LIGHTING - PHASE 1
E101.2 BASEMENT - LIGHTING - PHASE 2
E101.3 BASEMENT - LIGHTING - PHASE 3
E101.4 BASEMENT - LIGHTING - PHASE 4
E101.41 BASEMENT - LIGHTING - PHASE 4 - ALTERNATE 1
E101.42 BASEMENT - LIGHTING - PHASE 4 - ALTERNATE 2
E101.43 BASEMENT - LIGHTING - PHASE 4 - ALTERNATE 3
E101.44 BASEMENT - LIGHTING - PHASE 4 - ALTERNATE 4
E200 FIRST FLOOR - POWER - PHASE 2
E201 FIRST FLOOR - LIGHTING - PHASE 2
E301 FIRST FLOOR OVERALL AND ENLARGED ELECTRICAL PLANS
E400 ELECTRICAL DIAGRAMS
E601 ELECTRICAL DETAILS
E602 ELECTRICAL DETAILS
E603 ELECTRICAL DETAILS
E701 ELECTRICAL PANEL SCHEDULES
TECHNOLOGY
T001 TECHNOLOGY COVERSHEET
TD100.1 BASEMENT DEMOLITION - TECHNOLOGY- PHASE 1
TD100.2 BASEMENT DEMOLITION - TECHNOLOGY- PHASE 2
TD100.3 BASEMENT DEMOLITION - TECHNOLOGY- PHASE 3
TD100.4 BASEMENT DEMOLITION - TECHNOLOGY - PHASE 4
T002 OVERALL PLANS - TECHNOLOGY
T003 OVERALL PLANS - TECHNOLOGY
T100.1 BASEMENT - TECHNOLOGY - PHASE 1
T100.2 BASEMENT - TECHNOLOGY - PHASE 2
T100.3 BASEMENT - TECHNOLOGY - PHASE 3
T100.4 BASEMENT - TECHNOLOGY - PHASE 4
T100.41 BASEMENT - TECHNOLOGY - PHASE 4 - ALTERNATE 1
T100.42 BASEMENT - TECHNOLOGY - PHASE 4 - ALTERNATE 2
T100.43 BASEMENT - TECHNOLOGY - PHASE 4 - ALTERNATE 3
T100.44 BASEMENT - TECHNOLOGY - PHASE 4 - ALTERNATE 4
T200 TECHNOLOGY ROOM ENLARGEMENTS
T300 TECHNOLOGY DETAILS
T301 TECHNOLOGY DETAILS
T600 TECHNOLOGY SCHEDULES
Mark Revisions: Date:
VOL. 1
VOL. 2
VOL. 3
VOL. 4
VOL. 4
VOL. 5
VOL. 6
VOL. 6
VOL. 7
VOL. 8
H
C
C
1.
2.
3.
4.
5.
6.
UNLESS NOTED OTHERWISE, THE SIZE OF EACH BRANCH DUCT TO A TERMINAL AIR BOX
(TAB) SHALL MATCH THE INLET SIZE UNLESS THE BRANCH IS GREATER THAN 6FEET IN
LENGTH, IN WHICH CASE THE BRANCH DUCT SHALL BE SIZED AT A PRESSURE DROP OF
0.07"W.C. PER 100' OF DUCTWORK.
UNLESS NOTED OTHERWISE, THE SIZE OF EACH BRANCH DUCT TO AN AIR TERMINAL SHALL
MATCH THE INLET SIZE.
ALIGN TEMPERATURE SENSORS WITH LIGHT SWITCHES AND WHEN IN CLOSE PROXIMITY TO
EACH OTHER.
PROVIDE ACCESS DOORS AT ALL DUCT MOUNTED EQUIPMENT.
EXISTING AIR INLET AND OUTLET CFM SHOWN ON DRAWINGS ARE FROM EXISTING
DRAWINGS, AND ARE FOR REFERENCE ONLY. CONTRACTOR SHALL USE PRE-BALANCE
VALUES, AND NOT EXISTING CFM SHOWN ON DRAWINGS.
CONTRACTOR MAY REUSE PORTIONS OF EXISTING DUCT PROVIDED SIZES AND PRESSURE
CLASSES ARE CORRECT, DUCT IS THOROUGHLY CLEANED AND FREE OF DEFECTS, AND ALL
TRANSVERSE JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS ARE SEALED
AS SPECIFIED FOR NEW DUCTWORK.
VENTILATION GENERAL NOTES:
1.
2.
THE SIZE OF BRANCH PIPING TO TERMINAL HEATING DEVICES AND COILS SHALL BE 3/4"
UNLESS NOTED OTHERWISE.
PIPE DRAIN LINES FROM EQUIPMENT TO NEAREST FLOOR DRAIN.
PIPING GENERAL NOTES:
1.
2.
3.
4.
AFTER CONSTRUCTION ACTIVITIES ARE COMPLETE, TESTING, ADJUSTING (TAB) AND
BALANCING CONTRACTOR SHALL REBALANCE AIR HANDLING UNITS AND EXHAUST FANS AS
REQUIRED TO ACHIEVE THE NEW AIRFLOW VALUES SHOWN ON THE CONSTRUCTION
DRAWINGS.
AREAS SERVED BY THIS EQUIPMENT WHICH WERE NOT RENOVATED SHALL BE RE-
BALANCED TO THE AIRFLOW RATES MEASURED BEFORE THE RENOVATION OCCURRED
(REFER TO THE FINAL PRE- DEMOLITION REPORT).
TAB CONTRACTOR SHALL COMPILE AND SUBMIT COPIES OF THE FINAL POST-
CONSTRUCTION TAB REPORT AS REQUIRED BY SECTION 23 05 93.
THE FINAL POST CONSTRUCTION REPORT SHALL INCLUDE ALL ITEMS REQUIRED IN THE
SPECIFICATIONS.
TAB POST-CONSTRUCTION NOTES:
MECHANICAL GENERAL NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO, FIRE PROTECTION, PLUMBING, MEDICAL GAS, VENTILATION, PIPING AND TEMPERATURE
CONTROL.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC. ARE
DIAGRAMMATIC AND MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS.
DRAWINGS SHOW THE GENERAL ARRANGEMENT OF DUCTWORK, PIPING, EQUIPMENT, ETC.,
AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE
INSTALLATION. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING
CONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.
DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM
ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR
PHYSICALLY AT SITE. REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.
COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO PROVIDE
CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE, AND TO
VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO
VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES
OR CONFLICTS TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING
WITH FABRICATION OR EQUIPMENT ORDERS.
REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE
REASONABLE ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER
ACCESS.
ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO
COORDINATE SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST OR
EXPENSE TO OTHERS.
EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL
CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF
DESIGN.
REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY
AUDIO/VISUAL, AND OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING
MOUNTED DEVICES, OTHER THAN SPRINKLERS.
EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS,
FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS
RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND
FINISH.
IN AREAS WITH DRYWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS WITH THE
GC FOR ACCESS TO VALVES, DUCTWORK ACCESSORIES, DAMPERS, ETC. COORDINATE
PANEL TYPE AND COLOR WITH ARCHITECT. NOTIFY THE GC OF THE REQUIRED ACCESS
PANELS PRIOR TO BIDDING.
SEAL ALL FLOOR, WALL, AND ROOF PENETRATIONS AIRTIGHT WHERE CONDUITS, PIPING,
AND DUCTS PENETRATE. PENETRATIONS THROUGH EXTERIOR WALLS AND ROOF SHALL BE
SEALED AIRTIGHT WITH WATERPROOFING MATERIALS RECOMMENDED BY MANUFACTURER
FOR OUTDOOR USE.
CAULK ALL PIPE AND DUCT PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL,
PARTITION, FLOOR, AND ROOF ASSEMBLIES. THIS IS ESSENTIAL TO PREVENT NOISE
TRANSMISSION FROM ONE ROOM TO ANOTHER AND TO PROVIDE THE DESIRED NC LEVELS
WITHIN ROOMS.
WHERE PIPES AND DUCTS ARE SHOWN TO PENETRATE FLOORS, PROVIDE SLEEVED
OPENINGS WITH THE TOP EDGE RAISED ABOVE FLOOR SURFACE IN ACCORDANCE WITH ALL
RELEVANT SPEC SECTIONS. SEAL SLEEVE PERIMETER TO BE WATERTIGHT.
EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARY AMONG DIFFERENT
MANUFACTURERS. CONSULT APPROVED SHOP DRAWINGS FOR EQUIPMENT SIZES AND
REQUIRED SERVICE CLEARANCES. COORDINATE WITH LAYOUT OF EQUIPMENT PADS,
PIPING, DUCTWORK, ETC.
DO NOT BLOCK TUBE PULL OR EQUIPMENT SERVICE CLEARANCES.
MAINTAIN A MINIMUM WORKING CLEARANCE OF 3 ’-6” IN FRONT OF ALL ELECTRICAL
EQUIPMENT REQUIRING MAINTENANCE, INSPECTION, AND TESTING INCLUDING BUT NOT
LIMITED TO PANELS, DISTRIBUTION PANELS, SWITCHBOARDS, MOTOR CONTROL CENTERS,
TRANSFORMERS, EQUIPMENT DISCONNECTS AND STARTERS .
MAINTAIN THE DEDICATED ELECTRICAL EQUIPMENT SPACE DEFINED BY THE WIDTH / DEPTH
OF ELECTRICAL EQUIPMENT MEASURED FROM THE FLOOR TO A HEIGHT 6 ’-0” ABOVE THE
EQUIPMENT OR THE STRUCTURAL CEILING, WHICHEVER IS LOWER. SYSTEMS FOREIGN TO
THE ELECTRICAL DISTRIBUTION SYSTEM ARE NOT ALLOWED IN THE DEDICATED
ELECTRICAL SPACE INCLUDING; DUCTWORK, PIPING, ETC.
PROVIDE CONCRETE EQUIPMENT PAD FOR ALL FLOOR MOUNTED EQUIPMENT. PAD SHALL
EXTEND MINIMUM 6” BEYOND ALL SIDES OF EQUIPMENT.
DO NOT SUPPORT EQUIPMENT, PIPING, OR DUCTWORK FROM METAL DECKING OR OTHER
NON-STRUCTURAL BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE
CRACKED CONCRETE APPROVED IN ACCORDANCE WITH SPECIFICATIONS.
MECHANICAL RENOVATION NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO, FIRE PROTECTION, PLUMBING, MEDICAL GAS, VENTILATION, PIPING AND TEMPERATURE
CONTROL.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD
SURVEYS, EXISTING BUILDING DOCUMENTS, AND STAFF. VERIFY EXISTING CONDITIONS AND
REPORT ANY CONFLICTS BEFORE PROCEEDING.
NOT ALL EXISTING DUCTWORK AND PIPING IS SHOWN. VERIFY EXISTING CONDITIONS
BEFORE STARTING WORK. NOTIFY ENGINEER OF ANY CONFLICTS WITH NEW WORK.
FIELD VERIFY THE AVAILABLE CLEARANCES FOR DUCTWORK AND PIPING BEFORE
FABRICATION. RISES AND DROPS MAY BE NECESSARY BECAUSE OF EXISTING FIELD
CONDITIONS.
EACH CONTRACTOR SHALL FIELD VERIFY ACCESSIBILITY TO THE AREA OF THEIR WORK AND
SHALL NOTIFY THE GENERAL CONTRACTOR PRIOR TO BIDDING IF OTHER UTILITIES ARE
REQUIRED TO BE REMOVED OR RELOCATED TO ALLOW ACCESS TO THEIR AREA OF WORK.
THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CUTTING, REMOVAL AND PATCHING OF
ROOFS, WALLS, AND FLOORS ASSOCIATED WITH WORK BY ALL CONTRACTORS.
CONTRACTORS SHALL NOTIFY THE GC OF AFFECTED AREAS PRIOR TO BIDDING] [EACH
CONTRACTOR SHALL CUT AND PATCH ROOFS, WALLS, AND FLOORS ASSOCIATED WITH
THEIR WORK.
THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF
CEILINGS, CEILING TILES, AND CEILING GRIDS ASSOCIATED WITH AREAS OF WORK BY ALL
CONTRACTORS. NOTIFY THE GENERAL CONTRACTOR OF AFFECTED AREAS PRIOR TO
BIDDING.
WHERE EXISTING MECHANICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH
NEW EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL
EITHER ARRANGE NEW EQUIPMENT, PIPING, OR DUCTWORK IN SUCH A FASHION THAT IT
DOES NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING MECHANICAL
SYSTEMS TO ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR DUCTWORK.
PROVIDE TEMPORARY CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING
CONSTRUCTION. MAINTAIN ACCESS TO EXISTING MECHANICAL INSTALLATIONS THAT
REMAIN ACTIVE.
OBTAIN PERMISSION FROM OWNER BEFORE SHUTTING DOWN ANY SYSTEM FOR ANY
REASON. MAINTAIN SERVICE TO ALL COMPONENTS THAT ARE TO REMAIN UNTIL NEW
SYSTEMS ARE INSTALLED.
MAINTAIN EXISTING SYSTEM IN SERVICE UNTIL NEW SYSTEM IS COMPLETE AND READY FOR
TIE IN AND SWITCHOVER. DRAIN SYSTEM ONLY TO MAKE SWITCHOVERS AND
CONNECTIONS. OBTAIN PERMISSION FROM OWNER BEFORE PARTIALLY OR COMPLETELY
DRAINING SYSTEM. MAKE CHANGEOVER TO NEW SYSTEMS WITH MINIMUM OUTAGE.
DISCONNECT AND REMOVE MECHANICAL DEVICES AND EQUIPMENT SERVING EQUIPMENT
THAT HAS BEEN REMOVED.
MECHANICAL PHASING NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO, FIRE PROTECTION, PLUMBING, MEDICAL GAS, VENTILATION, PIPING AND TEMPERATURE
CONTROL.
1.
2.
3.
4.
5.
REFER TO ARCHITECTURAL DRAWINGS FOR GENERAL DESCRIPTION OF PHASES. REFER TO
GENERAL CONTRACTOR'S/ARCHITECT'S INSTRUCTIONS FOR MORE DETAILS AND PHASING
SCHEDULES AND FOR CONCURRENT WORK. MECHANICAL, ELECTRICAL AND TECHNOLOGY
DRAWINGS DEPICT THE INTENT OF THE FINAL DESIGN. THE MECHANICAL, ELECTRICAL, AND
TECHNOLOGY DRAWINGS DO NOT DEPICT THE MEANS AND METHODS TO MEET THE
REQUIREMENTS OF THE PHASING CRITERIA.
REVIEW PROJECT PHASING PLANS TO COORDINATE DEMOLITION WORK, OUTAGES, ETC.
WITH AFFECTED ADJACENT AREAS.
PROVIDE TEMPORARY DUCTWORK, PIPING, SHUTOFF VALVES, ZONE VALVES, ZONE
ALARMS, ETC. AS NEEDED TO MAINTAIN SERVICE TO ALL AREAS DURING ALL PHASES OF
PROJECT.
INSTALL TEMPORARY DUCTWORK, PIPING, SHUTOFF VALVES, ETC. AS NECESSARY TO KEEP
ALL OCCUPIED SPACES OPERATIONAL THROUGHOUT ALL PHASES OF THE PROJECT
PHASE DEMOLITION WORK TO MINIMIZE DOWNTIME.
CONTROL VALVE (TWO-WAY)
PITCH PIPE IN DIRECTION
DIELECTRIC CONNECTION
UNION/FLANGE
BALANCING VALVE (NUMBER INDICATES GPM)
PIPE CAP
PIPE DOWN
PIPE UP OR UP/DOWN
DIRECTION OF FLOW IN PIPE
SHUTOFF VALVE NORMALLY OPEN
SHUTOFF VALVE NORMALLY CLOSED
THROTTLING VALVE
MIXING VALVE
CONTROL VALVE (THREE-WAY)
SOLENOID VALVE
CHECK VALVE
SAFETY/RELIEF VALVE
PRESSURE REDUCING VALVE (LIQUID/GAS)
PRESSURE REDUCING VALVE (STEAM)
VACUUM BREAKER
"WYE" - STRAINER
"WYE" - STRAINER W/SHUTOFF VALVE AND HOSE CONNECTION WITH CAP
BASKET STRAINER
FLEXIBLE CONNECTION
PRESSURE/TEMPERATURE TEST PLUG
REDUCER - REFERENCE SPECIFICATION
FOR CONCENTRIC/ECCENTRIC AND FOT/FOB
SUCTION DIFFUSER WITH SUPPORT FOOT
AUTOMATIC AIR VENT
MANUAL AIR VENT
DRAIN VALVE WITH HOSE CONNECTION AND CAP
T T-*
STEAM TRAP (REFER TO SCHEDULE)
T-*
F&T STEAM TRAP (REFER TO SCHEDULE)
T-*
INVERTED BUCKET STEAM TRAP (REFER TO SCHEDULE)
ALIGNMENT GUIDE
PIPE ANCHOR
EXPANSION JOINT
#.#" IS THE EXPANSION TRAVEL INCHES
CLEAN STEAM - NUMBER INDICATES PRESSURE IN PSIG.CS15
CHILLED WATER RETURNCWR
CHILLED WATER SUPPLYCWS
HIGH PRESSURE CONDENSATEHPC
HEATING WATER RETURNHWR
HEATING WATER SUPPLYHWS
LOW PRESSURE CONDENSATELPC
PUMPED CONDENSATEPC
PUMPED DISCHARGEPD
SAFETY RELIEF VENTSV
STEAM - NUMBER INDICATES PRESSURE IN PSIG.S125
DRAINDPP
METERM
PUMP
STATIC SWITCH
PRESSURE GAUGE (FURNISHED WITH BALL VALVE)P
DIFFERENTIAL PRESSURE SENSOR
PRESSURE SENSOR (FURNISHED WITH BALL VALVE)P
FLOW METER
FM
FLOW SWITCH
F
FS FLOW SENSOR
MECHANICAL SYMBOL LIST
SYMBOL: DESCRIPTION:
NOT ALL SYMBOLS MAY APPLY.
OCCUPANCY SENSORO
HUMIDISTAT SENSOR
CARBON MONOXIDE SENSOR
CARBON DIOXIDE SENSOR
H HUMIDISTAT / SENSOR
TEMPERATURE SENSOR WITH WELL
T
THERMOMETER WITH WELL (DIAL TYPE)T
THERMOMETER WITH WELL (FILLED TYPE)
DIRECTION OF AIR FLOW
FLEXIBLE DUCT
MANUAL VOLUME DAMPER
RISE IN DIRECTION OF AIR FLOWR
DUCT CAP
DROP IN DIRECTION OF AIR FLOWD
DUCT DOWN
DUCT UP
SUPPLY/OUTSIDE AIR DUCT SECTION
RETURN AIR DUCT SECTION
EXHAUST/RELIEF AIR DUCT SECTION
4-WAY DIFFUSER WITH BLANKOFF IN ONE DIRECTION
SD-1
6/115
AIR TERMINAL PROPERTIES SYMBOL
NECK SIZE/CFM
TERMINAL AIR BOX (REFER TO SCHEDULE)###
### TERMINAL AIR BOX w/REHEAT COIL (REFER TO SCHEDULE)
HUMIDIFIERH
OPPOSED BLADE DAMPER (REFER TO SCHEDULE)
PARALLEL BLADE DAMPER (REFER TO SCHEDULE)
DIFFERENTIAL PRESSURE SENSOR
PRESSURE SENSOR/MONITORP
PRESSURE SENSOR (DUCT MOUNTED)P
THERMOSTAT/SENSORT
TEMPERATURE SENSORT
THERMOSTAT/SENSOR WITH HEAVY DUTY ENCLOSURET
MECHANICAL SYMBOL LIST
SYMBOL: DESCRIPTION:
AIRFLOW MEASUREMENT SYMBOL
XX - AHU SYMBOL
Y - SEQUENTIAL NUMBER
XX-Y
NOT ALL SYMBOLS MAY APPLY.
SP
BACKFLOW PREVENTER
EJ-#
CLEAN STEAM MEDIUM PRESSURE CONDENSATECMPC
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NAME
PLAN OR DETAIL SCALE
DETAIL REFERRED TO BY SECTION CUT
SHEET DETAIL IS LOCATED ON
NAME
1 VIEW NAME
1/8" = 1'-0"
M101
SIMSIM
INDICATES SIMILAR DETAIL REFERENCED
IN MULTIPLE LOCATIONS
LEVEL NAME
10'-0" HEIGHT ABOVE
PROJECT 0'-0"
1 INDICATES NOTE USED TO DESCRIBE
ADDITIONAL INFORMATION ABOUT
WORK REQUIRED, SPECIFIC TO THE
SHEET AND/OR DETAIL
N O R HT
INDICATES DIRECTION OF TRUE NORTH
VIEW KEY
LINE TYPE AND TAG KEY:
NEW WORK BY THIS CONTRACTOR (WIDE LINE)
NEW
EXISTING TO BE REMOVED (SHORT DASHED PATTERN)
NEW UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)
EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE)
EXISTING
EXISTING TO BE REMOVED BY OTHERS (SHORT DASHED PATTERN)
EXISTING UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)
HALFTONING DOES NOT MODIFY SCOPE.
'TAG'-E TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING
TAG-1 UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL
INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST
INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL
T101
SECURITY CONTRACTORS.C.
HEATING CONTRACTORH.C.
PLUMBING CONTRACTORP.C.
GENERAL CONTRACTORG.C.
MECHANICAL CONTRACTORM.C.
ELECTRICAL CONTRACTORE.C.
CONTRACTOR ABBREVIATION KEY
ABBR: DESCRIPTION:
TECHNOLOGY CONTRACTORT.C.
CONSTRUCTION MANAGERC.M.
MECHANICAL ABBREVIATION KEY
ABBR: DESCRIPTION:
DIFFERENTIAL PRESSURE GAUGE (RANGE)DPG (0-2")
DIFFERENTIAL PRESSURE SWITCHDPS
AD ACCESS DOOR
ABOVE FINISHED FLOORAFF
NOT IN CONTRACTNIC
CFSD CONTROL/FIRE/SMOKE DAMPER
EA EXHAUST/RELIEF AIR
FD FIRE DAMPER
FOB FLAT ON BOTTOM
FOT FLAT ON TOP
FSD FIRE/SMOKE DAMPER
MA MIXED AIR
OA OUTSIDE AIR
RA RETURN AIR
SA SUPPLY AIR
SD SMOKE DAMPER
TRANSFER DUCTTD
UC-1 DOOR UNDERCUT BY OTHERS (1" TYPICAL)
FD-E EXISTING FIRE DAMPER
FSD-E EXISTING FIRE SMOKE DAMPER
SD-E EXISTING SMOKE DAMPER
TERMINAL AIR BOXTAB
TYPICALTYP
UON UNLESS OTHERWISE NOTES
NORMALLY CLOSEDN.C.
NORMALLY OPENN.O.
PRESSURE SWITCHPS
MIXING VALVEMV
CO CLEANOUT
C COMMON
SCCR SHORT CIRCUIT CURRENT RATING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
556-402
ISSUED 11/29/2022
EXPAND STERILE PROCESSING
SERVICE (SPS)
100% CONSTRUCTION
DOCUMENTSAlesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
1070 Howard St Omaha, Nebraska 68102 Phone: (402) 455-7698 incandescence life safety, inc.
3575 Ringsby Ct Unit 408, Denver, CO 80216 Phone: (720) 722-3010
IMEG Corp.
263 Shuman Boulevard, Suite 550 Naperville, IL 60563 Phone: (630) 527-2320
Calibre Engineering, Inc.
9090 S Ridgeline Blvd #105, Highlands Ranch, CO 80129 Phone: (303) 730-0434
Force Protect Security Cons.
10901 Front Beach Road, Suite 1415 Panama City Beach, FL 32407
Captain James A. Lovell Federal Healthcare Center 3001 Green Bay Road, North Chicago, IL 60064
REV 6/14/2024
Au to de sk
D oc s:
//2
1-
-4
VA
E xp an d St er ile
P ro ce ss in g
Se rv ic es
(S
PS
D es ig n/ M
EP
T2
2_
.0
0_
JL
VA
-N or th
C hi ca go
- I L-
SP
S
Ex pa ns io n_ C
.rv t
6/
/2
8:
:1
AM
M000
MECHANICAL COVERSHEET
MRM NVP
133CA
MECHANICAL SHEET INDEX
M000 MECHANICAL COVERSHEET
MD100.1 BASEMENT DEMOLITION - VENTILATION - PHASE 1
MD100.2 BASEMENT DEMOLITION - VENTILATION - PHASE 2
MD100.3 BASEMENT DEMOLITION - VENTILATION - PHASE 3
MD100.4 BASEMENT DEMOLITION - VENTILATION - PHASE 4
MD101.2 FIRST FLOOR DEMOLITION - VENTILATION - PHASE 2
MD101.4 FIRST FLOOR DEMOLITION - VENTILATION - PHASE 4
MD102.4 SECOND FLOOR DEMOLITION – VENTILATION – PHASE 4
MD103.4 THIRD FLOOR DEMOLITION – VENTILATION – PHASE 4
MD104.4 FOURTH FLOOR DEMOLITION – VENTILATION – PHASE 4
MD2PB.2 PIPE BASEMENT DEMOLITION - PIPING - PHASE 2
MD200.4 BASEMENT DEMOLITION - PIPING - PHASE 4
M1PB.2 PIPE BASEMENT - VENTILATION - PHASE 2
M100.0 BASEMENT - VENTILATION - ALL PHASES
M100.1 BASEMENT - VENTILATION - PHASE 1
M100.2 BASEMENT - VENTILATION - PHASE 2
M100.3 BASEMENT - VENTILATION - PHASE 3
M100.4 BASEMENT - VENTILATION - PHASE 4
M100.41 BASEMENT – VENTILATION – PHASE 4 - BID ALTERNATE 1
M100.42 BASEMENT – VENTILATION – PHASE 4 - BID ALTERNATE 2
M100.43 BASEMENT – VENTILATION – PHASE 4 - BID ALTERNATE 3
M100.44 BASEMENT – VENTILATION – PHASE 4 - BID ALTERNATE 4
M101.0 FIRST FLOOR - VENTILATION - ALL PHASES
M101.2 FIRST FLOOR - VENTILATION - PHASE 2
M101.4 FIRST FLOOR - VENTILATION - PHASE 4
M102.0 SECOND FLOOR - VENTILATION - ALL PHASES
M102.2 SECOND FLOOR - VENTILATION - PHASE 2
M2PB.2 PIPE BASEMENT - PIPING - PHASE 2
M200.0 BASEMENT - PIPING - ALL PHASES
M200.2 BASEMENT - PIPING - PHASE 2
M200.4 BASEMENT - PIPING - PHASE 4
M200.44 BASEMENT – PIPING – PHASE 4 – BID ALTERNATE 4
M201.0 FIRST FLOOR - PIPING - ALL PHASES
M201.2 FIRST FLOOR - PIPING - PHASE 2
M300 MECHANICAL DETAILS
M301 MECHANICAL DETAILS
M302 MECHANICAL DETAILS
M303 MECHANICAL DETAILS
M304 AHU COMPONENT PLAN
M305 AIRFLOW MAP
M306 AIRFLOW MAP
M307 STEAM FLOW DIAGRAM
M400 MECHANICAL DIAGRAMS
M402 MECHANICAL DIAGRAMS
M401 MECHANICAL DIAGRAMS
M403 MECHANICAL DIAGRAMS
M600 MECHANICAL SCHEDULES
M601 MECHANICAL SCHEDULES
GRAND TOTAL: 48
263 SHUMAN BOULEVARD
SUITE 550
NAPERVILLE, IL 60563
P: 630.527.2320 www.imegcorp.com
Illinois Design Firm Registration #184.007637-0014
IMEG CORP. RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING
AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP. AND
SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT
WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF
IMEG CORP. ©2022 IMEG CORP.
REF. SCALE IN INCHES
0 1 2 3
PROJECT #21006895.00
Mark Revisions: Date:
MATTHEW R.
MEARS
062.058761
EXP.
11/30/202506/14/2024
T
TT
T
T
T
K
H
G
T
7.1
Q.1
Q.6
R
S
TT
Tt
S.
6 5
R.8
T.1
G.8
K.1
K.3
K.6
4 3 2 1
J
L L.1
7.8
.18 11.12.14.16.
.25
.T
PIPE BASEMENT
PC100
Not Enclosed
PIPE BASEMENT
PD100
6216 SF
2"VENT UP
8"VENT UP
3"HPS UP
2"PC UP
8"MPS UP
8"CWR UP
8"CWS UP
1 1/4"MPC UP
1 1/4"PC UP
6"CWS UP
6"CWR UP
2 1/2"PC UP
5"HPS UP
16"CWR
16"CWS
4" P C
8" H P S
4"CWR
4"CWS
1 1/4"MPC UP
1 1/4"HPC UP1"MPC UP1 1/4"HPS UP
1 1/4"MPS UP
1 1/4"HPS UP
1 1/4"MPS UP
5"MPS UP
2 1/2"MPC UP
1"MPC UP
1"HPC UP
1"MPC UP
UH-E
UH-E
UH-E
T T
UH-E
T
3/4"MPC UP
T
T
1 1/4"MPS
1"HPC
2"MPS
1 1/4"HPS
1 1/4"MPC
1" M P S
1" M P C
1"MPS 1"MPC
1 1/4"MPS
1 1/4"HPS
3/4"MPC
8" H P S
8" C W S 8" C W R
1 1/4"MPC
1 1/4"HPC
1 1/4"MPC
1 1/4"HPC
1"MPC
1"MPC
1" M P S
1/ 4" M P C
1" H P C
4"PC
4"CWS UP
4"CWR UP
UH-E
T
1"MPS
HPC
MPC
T
4" P C
1/ 4" H P S 1/ 4" M P S
2" M P S
HPS
MPS
MPS
MPC
HPC
4"PC
HPS
MPS
MPS
P-2 P-1
2"MPC UP
8"CWS
8"CWR
6"S125
8"MPC UP
6"CWS UP
6"CWR UP
4"PC UP
5"HPS UP
6"CWS
6"CWR
6" S1
2"
PC
6"S125
4"PC
1/ 2"
PC
5" S1
10" CWR
10" CWS
10"CWS
10"CWR
6"S125
4"PC
10"CWR
10"CWS
EXISTING CWS AND CWR PIPING TO BE
RELOCATED. REFER TO NEW WORK
PLAN FOR REVISED PIPING. COORDINATE
SHUTDOWNS OF EXISTING SYSTEM WITH
OWNER TO MINIMIZE DISRUPTIONS.
CUT PIPING AS SHOWN AND
PREPARE FOR NEW
CONNECTIONS. COORDINATE
SHUTDOWNS OF EXISTING
SYSTEM WITH OWNER TO
MINIMIZE DISRUPTIONS.
10"CWS
10"CWR
CUT PIPING AS SHOWN AND PREPARE FOR
NEW CONNECTIONS. COORDINATE
SHUTDOWNS OF EXISTING SYSTEM WITH
OWNER TO MINIMIZE DISRUPTIONS.
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
556-402
ISSUED 11/29/2022
EXPAND STERILE PROCESSING
SERVICE (SPS)
100% CONSTRUCTION
DOCUMENTSAlesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
1070 Howard St Omaha, Nebraska 68102 Phone: (402) 455-7698 incandescence life safety, inc.
3575 Ringsby Ct Unit 408, Denver, CO 80216 Phone: (720) 722-3010
IMEG Corp.
263 Shuman Boulevard, Suite 550 Naperville, IL 60563 Phone: (630) 527-2320
Calibre Engineering, Inc.
9090 S Ridgeline Blvd #105, Highlands Ranch, CO 80129 Phone: (303) 730-0434
Force Protect Security Cons.
10901 Front Beach Road, Suite 1415 Panama City Beach, FL 32407
KEY PLAN
Captain James A. Lovell Federal Healthcare Center 3001 Green Bay Road, North Chicago, IL 60064
REV 6/14/2024
Au to de sk
D oc s:
//2
1-
-4
VA
E xp an d St er ile
P ro ce ss in g
Se rv ic es
(S
PS
D es ig n/ M
EP
T2
2_
.0
0_
JL
VA
-N or th
C hi ca go
- I L-
SP
S
Ex pa ns io n_ C
.rv t
6/
/2
8:
:2
AM
MD2PB.2
PIPE BASEMENT DEMOLITION - PIPING
- PHASE 2
PGP NVP
133CA
N O R HT
1/8" = 1'-0"
PIPE BASEMENT DEMOLITION - PIPING - PHASE 21
263 SHUMAN BOULEVARD
SUITE 550
NAPERVILLE, IL 60563
P: 630.527.2320 www.imegcorp.com
Illinois Design Firm Registration #184.007637-0014
IMEG CORP. RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING
AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP. AND
SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT
WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF
IMEG CORP. ©2022 IMEG CORP.
REF. SCALE IN INCHES
0 1 2 3
PROJECT #21006895.00
Mark Revisions: Date:
MATTHEW R.
MEARS
062.058761
EXP.
11/30/202506/14/2024
T
T
T
T T
T T
T
T
T
T
T
T
P
P
K
H
G
T
7.1
Q.1
Q.6
R
S
TT
Tt
S.
J
L
7.8
.18 11.12.14.16.
.25
.T
24x10
CD-E
TAB-E
48x16
48x14
TAB-E
16x10
EG-E
CD-E
CD-E
CD-E
TAB
CD-E
TAB
CD-E
CD-E
12x6CD-E
12x6 CD
12x8
12x8
CD-E
RG-E
10x6
CD-E
CD
10x6
10x6
12x10
10x6
CD-E
CD-E
10x6
TAB8x8
TAB
x1
16x12 14x12
CD-E
CD-E
18x10
RG-E
24x7
10x6
10x6
24x7
32x10
10x6
RG-E
12x8
EG-E
CD-E
8x8
8x8
8x8 22 x1
10x6
8x8 EG-E
EG-E
CD-E
24x10
CD CD
10x8
TAB
CD-E
CD-E
TAB-E
CD-E
RG
CD-E
10x10
EG-E
14x8 8x6
10x14
10x6 10x6
TAB-E
20x1222x12
8x626x12
8x8 14x612x6
TAB-E
SG-E
EG-E
14x10
CD-E
RG-E
TAB-E
RG-E
8x6
RG-E
10x6
32x10 x1 x1
20x10
24x10
48x12 x1
38x10
26x10
CD-E
CD-E
RG-E
8x8
26x10 52x10
RG-E CD-E
TAB
CD-E CD-E22x14
EG-E
x1
34x10
32x10
CD-E
CD-E RG-E
RG-E
RG-E
x1 x1
24x12 x1
36x10
12x8
14x10
16x10
12x6
EG-EEG-E
14x8
CD-E
EG-E
12x6
CD-E
10x14
8x8 x2 x1 2 10x6
8x8
CD-E
CD-E
8x6
TAB-E
8x6
22x10 EA UP
14x10 EA UP
TO EF-33
14x10 EA UP
TO EF-25
TAB
EG-E
CD-E
CD-E
x6
12x10 x8
CD-E
TAB
x1
0 CD-E
TAB
TAB
12x14
12x14
RG-E
12x8 10x6
12x8
10x6 x1
48x20 RA UP 60x20 SA UP
20x8 EA UP
CD-E
RG-E
36x6
40x12 RA UP
12x10
RG-E
x1 026x6
RG-E
x1
RG-E
48x16 RA UP 48x16 SA UP
18x12
CD-E
16x6
10x4
10x8
10x8
CD-E
CD-E
TAB-E
TAB-E
x2 x2
RG-E
CD-E
x1 x1 x8
20x8
40x10
CD-E
x1 0 16x10 SA UP
20x12 RA DN TO
MECH ROOM
TAB-E
18x8
22x10 x1
RG-E
RG-E
52x10 EA UP x1
TAB
CD-E
EG-E
EG-E
12x4 x6
RG-E
RG-E
CD-E
RG-E
RG-E
x1
CD-E
RG-E
RG-E
RG-E
RG-E
RG-E
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
556-402
ISSUED 11/29/2022
EXPAND STERILE PROCESSING
SERVICE (SPS)
100% CONSTRUCTION
DOCUMENTSAlesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
1070 Howard St Omaha, Nebraska 68102 Phone: (402) 455-7698 incandescence life safety, inc.
3575 Ringsby Ct Unit 408, Denver, CO 80216 Phone: (720) 722-3010
IMEG Corp.
263 Shuman Boulevard, Suite 550 Naperville, IL 60563 Phone: (630) 527-2320
Calibre Engineering, Inc.
9090 S Ridgeline Blvd #105, Highlands Ranch, CO 80129 Phone: (303) 730-0434
Force Protect Security Cons.
10901 Front Beach Road, Suite 1415 Panama City Beach, FL 32407
KEY PLAN
Captain James A. Lovell Federal Healthcare Center 3001 Green Bay Road, North Chicago, IL 60064
REV 6/14/2024
Au to de sk
D oc s:
//2
1-
-4
VA
E xp an d St er ile
P ro ce ss in g
Se rv ic es
(S
PS
D es ig n/ M
EP
T2
2_
.0
0_
JL
VA
-N or th
C hi ca go
- I L-
SP
S
Ex pa ns io n_ C
.rv t
6/
/2
8:
:3
AM
MD100.1
BASEMENT DEMOLITION -
VENTILATION - PHASE 1
MRM NVP
133CA
N O R HT
1/8" = 1'-0"
BASEMENT DEMOLITION - VENTILATION - PHASE 11
263 SHUMAN BOULEVARD
SUITE 550
NAPERVILLE, IL 60563
P: 630.527.2320 www.imegcorp.com
Illinois Design Firm Registration #184.007637-0014
IMEG CORP. RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING
AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP. AND
SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT
WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF
IMEG CORP. ©2022 IMEG CORP.
REF. SCALE IN INCHES
0 1 2 3
PROJECT #21006895.00
Mark Revisions: Date:
MATTHEW R.
MEARS
062.058761
EXP.
11/30/202506/14/2024
T
T
T
T T
T T
T
T
T
T
T
T
P
P
K
H
G
T
7.1
Q.1
Q.6
S
TT
Tt
S.
J
L
.18 11.12.14.16.
.25
.T
TAB-E
TAB-E
TAB-E
TAB-E
TAB-E
TAB-E
TAB-E
22x10 EA UP
14x10 EA UP
TO EF-33
14x10 EA UP
TO EF-25
48x20 RA UP 60x20 SA UP
20x8 EA UP
40x12 RA UP
48x16 RA UP 48x16 SA UP
TAB-E
TAB-E
16x10 SA UP
20x12 RA DN TO
MECH ROOM
TAB-E
52x10 EA UP
RG-E
RG-E
CD-E
CD-E
CD-E
CD-E
CD-E
CD-E
CD-E
CD-E
CD-E
RG-E
CD-E
CD-E
CD-E
CD-E
RG-ERG-E
EG-E
CD-EEG-E
EG-E
CD-E
CD-E
CD-E
CD-E
EG-E
SG-E
EG-E
CD-E
RG-E
RG-E
RG-E
CD-E
CD-E
RG-E
RG-E CD-E
CD-E CD-E
EG-E
CD-E
CD-E RG-E
RG-E
RG-E
EG-EEG-E CD-E
EG-E
CD-E
CD-E
CD-E
EG-E
CD-E
CD-E
CD-E
CD-E
RG-E
CD-E
RG-E
RG-E
RG-E
RG-E
CD-E
CD-E
CD-E
RG-E
CD-E
CD-E
RG-E
RG-E
CD-E
EG-E
EG-E
RG-E
RG-E
CD-E
RG-E
RG-E
CD-E
RG-E
RG-E
CD-E
CD-E
48x16
48x14
16x10
12x6
12x8
12x8 10x6
10x6
12x10
10x6
10x6
8x8 x1
16x12 14x12
18x10 24x7
10x6
10x6
24x7
32x10
10x6
12x8
8x8
8x8
8x8 22 x1
10x6
8x8
24x10 10x8
10x10
14x8 8x6
10x14
10x6 10x6
20x1222x12
26x12
8x8 14x612x6
14x10
8x6 10x6
32x10 x1 x1
20x10
24x10
48x12 x1
38x10
26x10
8x8
26x10 52x10
22x14 x1
34x10
32x10 x1 2 24 x1
24x12 x1
36x10
12x8
14x10
16x10
12x6 14x8
12x6
10x14
8x8 x2 x1 2 10x6
8x8
8x6
8x6 x6
12x10 x8 x1
12x14
12x14
12x8 10x6
12x8
10x6 x1
36x6
12x10 x1 026x6 x1
18x12
16x6
10x4
10x8
10x8 x2 x2 x1 x1 x8
20x8
40x10 x1
18x8
22x10 x1 x1
12x4 x6 x1
18x12 EA UP 24x12 EA UP
TAB-E
TAB
TAB
TAB
TAB
TAB-E
TAB-E
TAB-E
TAB-E
TAB
TAB-E
TAB
TAB
TAB
TAB
TAB-E
TAB-E
TAB
TAB-E
TAB
CD
RG-E
CD-ECD-E
CD-E
RG-E
CD-E
CD-E
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
556-402
ISSUED 11/29/2022
EXPAND STERILE PROCESSING
SERVICE (SPS)
100% CONSTRUCTION
DOCUMENTSAlesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
1070 Howard St Omaha, Nebraska 68102 Phone: (402) 455-7698 incandescence life safety, inc.
3575 Ringsby Ct Unit 408, Denver, CO 80216 Phone: (720) 722-3010
IMEG Corp.
263 Shuman Boulevard, Suite 550 Naperville, IL 60563 Phone: (630) 527-2320
Calibre Engineering, Inc.
9090 S Ridgeline Blvd #105, Highlands Ranch, CO 80129 Phone: (303) 730-0434
Force Protect Security Cons.
10901 Front Beach Road, Suite 1415 Panama City Beach, FL 32407
KEY PLAN
Captain James A. Lovell Federal Healthcare Center 3001 Green Bay Road, North Chicago, IL 60064
REV 6/14/2024
Au to de sk
D oc s:
//2
1-
-4
VA
E xp an d St er ile
P ro ce ss in g
Se rv ic es
(S
PS
D es ig n/ M
EP
T2
2_
.0
0_
JL
VA
-N or th
C hi ca go
- I L-
SP
S
Ex pa ns io n_ C
.rv t
6/
/2
8:
:4
AM
MD100.2
BASEMENT DEMOLITION -
VENTILATION - PHASE 2
MRM NVP
133CA
N O R HT
1/8" = 1'-0"
BASEMENT DEMOLITION - VENTILATION - PHASE 21
263 SHUMAN BOULEVARD
SUITE 550
NAPERVILLE, IL 60563
P: 630.527.2320 www.imegcorp.com
Illinois Design Firm Registration #184.007637-0014
IMEG CORP. RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING
AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP. AND
SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT
WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF
IMEG CORP. ©2022 IMEG CORP.
REF. SCALE IN INCHES
0 1 2 3
PROJECT #21006895.00
Mark Revisions: Date:
MATTHEW R.
MEARS
062.058761
EXP.
11/30/202506/14/2024
UP
UP
UP
DN
T
T
T
T
T
T T
T T
T
T
T
T
T
T
T
T
T
T
T
T
P
P
PP
P
P
P
T
T
TP
K
H
G
T
7.1
Q.1
Q.6
R
S
TT
Tt
S.
6 5
R.8
T.1
G.8
K.1
K.3
K.6
4 3 2 1
J
L L.1
7.8
.18 11.12.14.16.
.25
.T
EXIST EJ
EXIST EJ
EXIST EJ
EXIST EJ
CD-E
TAB-E
48x16
48x14
TAB-E
16x10
EG-E
CD-E
CD
CD
TAB
CD
TAB
CD
CD
CD-E
12x6
12x8
12x8
CD-E
RG-E
10x6
CD
10x6
12x10
10x6
CD-E
CD-E
10x6
TAB8x8
TAB
x1
16x12 14x12
CD-E
CD-E
18x10
RG
24x7
10x6
10x6
24x7
32x10
10x6
RG-E
12x8
EG-E
CD-E
8x8
8x8
8x8 22 x1
10x6
8x8 EG-E
EG-E
CD-E
24x10 10x8
CD-E
TAB-E
CD-E
CD-E
10x10
EG-E
14x8 8x6
10x14
10x6 10x6
TAB-E
20x1222x12
26x12
8x8 14x612x6
TAB-E
SG-E
EG-E
14x10
CD-E
RG-E
TAB-E
RG-E
8x6
RG-E
10x6
32x10 x1 x1
20x10
24x10
48x12 x1
38x10
26x10
CD-E
CD-E
RG-E
8x8
26x10 52x10
RG
CD-E
TAB
CD CD-E22x14
EG-E
x1
34x10
32x10
CD-E
CD-E RG-E
RG-E
RG-E
x1 2 24 x1
24x12 x1
36x10
12x8
14x10
16x10
12x6
EG-EEG-E
14x8
CD-E
EG-E
12x6
CD-E
10x14
8x8 x2 x1 2 10x6
8x8
CD-E
CD-E
8x6
TAB-E
8x6
22x10 EA UP
14x10 EA UP
TO EF-33
14x10 EA UP
TO EF-25
TAB
EG-E
CD-E
CD-E
x6
12x10 x8
CD-E
TAB
x1
0 CD-E
TAB
TAB
12x14
12x14
RG-E
12x8 10x6
12x8
10x6 x1
48x20 RA UP 60x20 SA UP
20x8 EA UP
CD-E
RG-E
36x6
40x12 RA UP
12x10
RG-E
x1 026x6
RG-E
x1
RG-E
48x16 RA UP 48x16 SA UP
18x12
CD-E
16x6
10x4
10x8
10x8
CD-E
CD-E
TAB-E
TAB-E
x2 x2
RG-E
CD-E
x1 x1 x8
20x8
40x10
CD-E
x1 0 16x10 SA UP
20x12 RA DN TO
MECH ROOM
TAB-E
18x8
22x10 x1
RG-E
RG-E
52x10 EA UP x1
TAB
CD-E
EG-E
EG-E
12x4 x6
RG-E
RG-E
CD-E
RG-E
RG-E
x1
CD
RG-E
RG-E
RG-E
RG-E
TAB-E
CD-E
CD-E
TAB-102
34x12
TAB-103
18x12 EA UP 24x12 EA UP x1
TAB-108E
TAB-101E
TAB-101
TAB-107E
TAB-104
TAB-106
TAB-104E
TAB-102E
TAB-102
TAB-105
TAB-103
TAB-108
10x10
12x10
40x12
40x12
12x10 EA DN 12x10 SA DN
12x10 EA
UP
48x12 EA UP
TAB-108
TAB-107
TAB-106
TAB-105
TAB-103
TAB-101
x1
8x8 EA
UP
8x8
8x8
FD
EG-E
10/250
(TYP.4)
CD-E
8/125
CD-E
12/400
TAB-109
TAB-109
x1
16x12
CD-E
10/300
(TYP.6)
x1
EG-E
10/240
(TYP.2)
22x12
12x12
16x10
12x8
EG-E
12/275
CD-E
12/325
CD-E
12/325
12x12
10x10
EG-E
12/325
12x8 12x8
SG-E
16x16/725
34x12
SA UP
22x6
22x6
16x10
EG-E
22x22/625
(TYP.2)
EG-E
18x18/850
EG-E
18x18/850
SG-E
16x16/750
28x12
CD-E
10/300
CD-E
10/275
CD-E
10/275
(TYP.3)
8x8
10x12
CD-E
8/125
CD-E
10/250
(TYP.2)
CD-E
12/400
CD-E
12/375 CD-E
12/375
16x12
CD-E
10/275
EG-E
12/350
EG-E
8/125
CD-E
12/325
EG-E
12/400 x1
CD-E
8/75
TAB-103
46x1234x12
34x12 x1
CD-E
10/300
(TYP.8)
10x8 10x8
10x8
10x8
10x8 10x8
10x8
CD-E
10/300
CD-E
10/300
CD-E
10/300
20x10 x1
10x8
8x6
12x8 x1
28x12
EG-E
22x22/800
(TYP.4)
EG-E
22x22/825
(TYP.2)
30x12
12x8
EG-E
12/275 x1
22x12
40x12 SAUP
22x12 SAUP 42x14
24x12 SA
UP
x1
16x12
SA UP
x1
50x12 48x12
10x12
EG-E
10/300
EG-E
10/300
14x12 14x12
22x14 EA
UP
10x8 12x10 x1
CD-E
8/75
12x1012x8
TAB-102
TAB-104
TAB-107
CD-E
8/125
EG-E
8/200
CD-E
CD-E
RG-E
SG-E
6x6/50
FD
FD
RG-E
50x12 EA UP
40x12 EA UP 36x12 EA UP x1
14x8
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
556-402
ISSUED 11/29/2022
EXPAND STERILE PROCESSING
SERVICE (SPS)
100% CONSTRUCTION
DOCUMENTSAlesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
1070 Howard St Omaha, Nebraska 68102 Phone: (402) 455-7698 incandescence life safety, inc.
3575 Ringsby Ct Unit 408, Denver, CO 80216 Phone: (720) 722-3010
IMEG Corp.
263 Shuman Boulevard, Suite 550 Naperville, IL 60563 Phone: (630) 527-2320
Calibre Engineering, Inc.
9090 S Ridgeline Blvd #105, Highlands Ranch, CO 80129 Phone: (303) 730-0434
Force Protect Security Cons.
10901 Front Beach Road, Suite 1415 Panama City Beach, FL 32407
KEY PLAN
Captain James A. Lovell Federal Healthcare Center 3001 Green Bay Road, North Chicago, IL 60064
REV 6/14/2024
Au to de sk
D oc s:
//2
1-
-4
VA
E xp an d St er ile
P ro ce ss in g
Se rv ic es
(S
PS
D es ig n/ M
EP
T2
2_
.0
0_
JL
VA
-N or th
C hi ca go
- I L-
SP
S
Ex pa ns io n_ C
.rv t
6/
/2
8:
:5
AM
MD100.3
BASEMENT DEMOLITION -
VENTILATION - PHASE 3
MRM NVP
133CA
N O R HT
1/8" = 1'-0"
BASEMENT DEMOLITION - VENTILATION - PHASE 31
263 SHUMAN BOULEVARD
SUITE 550
NAPERVILLE, IL 60563
P: 630.527.2320 www.imegcorp.com
Illinois Design Firm Registration #184.007637-0014
IMEG CORP. RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING
AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP. AND
SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT
WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF
IMEG CORP. ©2022 IMEG CORP.
REF. SCALE IN INCHES
0 1 2 3
PROJECT #21006895.00
Mark Revisions: Date:
MATTHEW R.
MEARS
062.058761
EXP.
11/30/202506/14/2024
T
T
T
T T
T T
T
T
T
T
T
T
T
T
T
T
T
T
P
P
PP
P
P
P
T
T
TP
K
H
G
T
7.1
Q.1
Q.6
R
S
TT
Tt
S.
6 5
R.8
T.1
G.8
K.1
K.3
K.6
4 3 1
J
L L.1
7.8
.18 11.12.14.16.
.25
.T
CD-E
TAB-E
48x16
48x14
TAB-E
16x10
EG-E
CD-E
TAB
CD
12x6
12x8
12x8
CD
RG
10x6
10x6 12x10
10x6
CD
CD
10x6
TAB8x8
TAB
x1
16x12 14x12
CD
CD
18x10 10x6
10x6
24x7
32x10
10x6
RG
12x8
EG
CD
8x8
8x8
8x8 22 x1
10x6
8x8 EG
EG
CD
24x10 10x8
CD-E
TAB-E
CD-E
CD-E
10x10
EG-E
14x8 8x6
10x14
10x6 10x6
TAB-E
20x1222x12
26x12
8x8 14x612x6
TAB-E
SG-E
EG-E
14x10
CD-E
RG-E
TAB-E
RG-E
8x6
RG-E
10x6 x1 x1
20x10
24x10
48x12 x1
38x10
26x10
CD-E
CD-E
RG-E
8x8
26x10 52x10
CD
TAB
CD
22x14
EG
x1
34x10
32x10
CD-E
CD-E RG-E
RG-E
RG-E
x1
2 24 x1
24x12 x1
36x10
12x8
14x10
16x10
12x6
EGEG
14x8
CD
EG
12x6
CD
10x14
8x8 x2 x1 2 10x6
8x8
CD-E
CD-E
8x6
TAB-E
8x6
22x10 EA UP
TO EF-35
14x10 EA UP
TO EF-33
14x10 EA UP
TO EF-25
TAB
EGCD
CD
x6 x8
CD
TAB
x1
0 CD
TAB
TAB
12x14
12x14
RG
12x8
12x8
10x6 x1
48x20 RA UP 60x20 SA UP
20x8 EA UP
CD-E
36x6
40x12 RA UP
12x10
RG
x1
026x6
RG
x1
RG
48x16 RA UP 48x16 SA UP
18x12
CD
10x4
10x8
10x8
CD-E
CD-E
TAB-E
TAB-E
x2 x2
RG-E
CD-E
x1 x1 x8
20x8
40x10
CD-E
x1 0 16x10 SA UP
20x12 RA DN TO
MECH ROOM
TAB-E
18x8
22x10 x1
RG
RG
52x10 EA UP x1
TAB
CD
EG-E
EG-E
12x4 x6
RG-E
RG-E
CD
RG
RG
x1
RG
RG
RG-E
RG-E
TAB-E
CD-E
CD-E
18x12 EA UP 24x12 EA UP x1
TAB-108E
TAB-101E
TAB-101
TAB-107E
TAB-104
TAB-106
TAB-104E
TAB-102E
TAB-102
TAB-105
TAB-103
TAB-108
10x10
12x10
40x12
40x12
12x10 EA DN 12x10 SA DN
12x10 EA
UP
48x12 EA UP
TAB-108
TAB-107
TAB-106
TAB-105
TAB-103
TAB-101
x1
8x8 EA
UP
8x8
8x8
FD
EG-E
10/250
(TYP.4)
CD-E
8/125
CD-E
12/400
TAB-109
TAB-109
x1
16x12
CD-E
10/300
(TYP.6)
x1
EG-E
10/240
(TYP.2)
22x12
12x12
16x10
12x8
EG-E
12/275
CD-E
12/325
CD-E
12/325
12x12
10x10
EG-E
12/325
12x8 12x8
SG-E
16x16/725
34x12
SA UP
22x6
22x6
16x10
EG-E
22x22/625
(TYP.2)
EG-E
18x18/850
EG-E
18x18/850
SG-E
16x16/750
28x12
CD-E
10/300
CD-E
10/275
CD-E
10/275
(TYP.3)
8x8
10x12
CD-E
8/125
CD-E
10/250
(TYP.2)
CD-E
12/400
CD-E
12/375 CD-E
12/375
16x12
CD-E
10/275
EG-E
12/350
EG-E
8/125
CD-E
12/325
EG-E
12/400 x1
CD-E
8/75
TAB-103
46x1234x12
34x12 x1
CD-E
10/300
(TYP.8)
10x8 10x8
10x8
10x8
10x8 10x8
10x8
CD-E
10/300
CD-E
10/300
CD-E
10/300
20x10 x1
10x8
8x6
12x8 x1
14x8
28x12
48x12
EG-E
22x22/800
(TYP.4)
EG-E
22x22/825
(TYP.2)
30x12
12x8
EG-E
12/275 x1
22x12
40x12 SAUP
22x12 SAUP 42x14
24x12 SA
UP
x1
16x12
SA UP
x1
50x12 48x12
10x12
EG-E
10/300
EG-E
10/300
14x12 14x12
22x14 EA
UP
10x8 12x10 x1
CD-E
8/75
12x1012x8
TAB-102
TAB-104
TAB-107
CD-E
8/125
EG-E
8/200
CD
CD
RG
CD
RGRG
SG
FD
SS-1 SS-1
32x10 32x10
RG CD
FD
50x12 EA UP
40x12 EA UP 36x12 EA UP
CD-E
8/125
SSCU-1 SSCU-1
DEMO CAP AND
PREPARE FOR NEW
CONNECTION.
DEMO CAP AND
PREPARE FOR NEW
CONNECTION.
DEMO CAP AND
PREPARE FOR NEW
CONNECTION.
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
556-402
ISSUED 11/29/2022
EXPAND STERILE PROCESSING
SERVICE (SPS)
100% CONSTRUCTION
DOCUMENTSAlesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
1070 Howard St Omaha, Nebraska 68102 Phone: (402) 455-7698 incandescence life safety, inc.
3575 Ringsby Ct Unit 408, Denver, CO 80216 Phone: (720) 722-3010
IMEG Corp.
263 Shuman Boulevard, Suite 550 Naperville, IL 60563 Phone: (630) 527-2320
Calibre Engineering, Inc.
9090 S Ridgeline Blvd #105, Highlands Ranch, CO 80129 Phone: (303) 730-0434
Force Protect Security Cons.
10901 Front Beach Road, Suite 1415 Panama City Beach, FL 32407
KEY PLAN
Captain James A. Lovell Federal Healthcare Center 3001 Green Bay Road, North Chicago, IL 60064
REV 6/14/2024
Au to de sk
D oc s:
//2
1-
-4
VA
E xp an d St er ile
P ro ce ss in g
Se rv ic es
(S
PS
D es ig n/ M
EP
T2
2_
.0
0_
JL
VA
-N or th
C hi ca go
- I L-
SP
S
Ex pa ns io n_ C
.rv t
6/
/2
8:
:1
AM
MD100.4
BASEMENT DEMOLITION -
VENTILATION - PHASE 4
MRM NVP
133CA
N O R HT
1/8" = 1'-0"
BASEMENT DEMOLITION - VENTILATION - PHASE 41
1.
KEYNOTES:
REMOVE EXISTING PRESSURE MONITORING
SYSTEM AND ASSOCIATED CONTROLS.
1.
2.
3.
4.
SHEET NOTES:
REMOVE EXISTING TERMINAL AIR BOX, AND
ASSOCIATED SUPPLY/RETURN DUCTWORK AS
SHOWN BACK TO ACTIVE MAIN AND CAP OR
PATCH. REMOVE ASSOCIATED CONTROLS AND
THERMOSTAT. REBALANCE EXISTING AIR
HANDLER AS REQUIRED PER REVISED FLOOR
PLAN.
REMOVE EXISTING EXHAUST DUCTWORK AND
GRILLES AS SHOWN BACK TO ACTIVE MAIN
AND CAP OR PATCH. REBALANCE EXISTING
EXHAUST FAN SERVING REVISED FLOOR PLAN
AS REQUIRED.
REMOVE DUCTWORK AS SHOWN BACK TO
ACTIVE MAIN AND CAP OR PATCH.
COORDINATE SHUTDOWNS OF EXISTING
SYSTEM TO MINIMIZE DISRUPTIONS.
263 SHUMAN BOULEVARD
SUITE 550
NAPERVILLE, IL 60563
P: 630.527.2320 www.imegcorp.com
Illinois Design Firm Registration #184.007637-0014
IMEG CORP. RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING
AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP. AND
SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT
WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF
IMEG CORP. ©2022 IMEG CORP.
REF. SCALE IN INCHES
0 1 2 3
PROJECT #21006895.00
Mark Revisions: Date:
MATTHEW R.
MEARS
062.058761
EXP.
11/30/202506/14/2024
T
T
T
T
T
T T
T
T
T
K
H
G
T
7.1
Q.1
Q.6
R
S
TT
Tt
S.
6 5
R.8
T.1
G.8
K.1
K.3
K.6
4 3 2 1
J
L L.1
7.8
.18 11.12.14.16.
.25
.T
AHU-3
AHU-4
22x10 EA DN &
UP TO EF-35
14x10 EA DN &
UP TO EF-33
14x10 EA DN &
UP TO EF-25
48x20 RA DN
60x20 SA DN
20x8 EA DN
40x12 RA DN
48x16 RA DN
48x16 SA DN
16x10 RA DN
20x12 RA DN TO
MECH ROOM
52x10 EA DN
L
L
DS-E
55ø
60x30
52x20 x8
EF-E
20x8
48x14 DS-E
DS-E
EF-E
48x14
24x10 x1
48x16 48x16
48x14
28x28 EA UP
TO EF-28
RF-E
DS-E
60x20 x2
29x29 EA UP48x14
48x14 x1
42x42
36x36
18x18 EA UP
18x18
FD-E
FD-E
FD-E
FD-E
12x10
RG-E
TAB-E
CD-E CD-E
8x14
12x14
14x14
CD-E
CD-E
CD-E
CD-E
CD-E
CD-E
8x6
8x6
CD-ERG-E
TAB-E
12x14
14x14
CD-E
16x12
10x6
8x6
8x6
10x6
8x6
EG-E
14x10
14x8
CD-E CD-E
10x6 8x6
8x68x6
12x10
12x10
12x8
EG-E
CD-E14x6
RG-E24x10
TAB-E
RG-E
14x10
22x1234x1240x12
TAB-E
12x8
14x10
CD-E
TAB-E
CD-E
10x6
RG-E
8x6
8x6
12x8
CD-E
RG-E
10x6
RG-E
CD-E
12x8
12x8
10x6
CD-E
RG-E
RG-E
8x6
TAB-E
10x8
12x8
10x8
10x6
CD-E
16x12
CD-E
RG-E
CD-E
8x6
10x6
10x6
TAB-E
x1 x1
CD-ECD-ECD-E
12x6
10x6
12x10
10x6
14x10 x1
EG-E
22x10 EA DN &
UP TO EF-26
CD-ERG-E
TAB-E
EG-E
CD-E
10x6
8x6
EG-E
8x6 x1
8x6
RG-E
CD-E
CD-E
CD-E
CD-E
12x6
12x10
EG-E
TAB-E
8x6
CD-E
10x6 16x8 10x8
8x612x6
RG-E
48x14 26x1236x14
10x8 12x8
CD-E
CD-E TAB-E
12x10
RG-E
10x6 RG-E
RG-E
CD-E
RG-E
CD-E
8x6
10x6
RG-E
EG-E
TAB-E
CD-E
12x10
CD-E
EG-E EG-E
14x614x6
16x12 x1
RG-E
14…
This is the start of the file's text. The full file is on GovTribe.