Attachment 6 - Drawing 3 of 7.pdf
PDF 12 MB Posted
- Attached to
- Y1DA--EHRM Infrastructure Upgrade Construction Fort Meade VAMC Federal contract opportunity
- Solicitation number
- 36C77622B0055
About this file
This document provides details on a federal solicitation for construction services. The solicitation number is 36C77622B0055 from the Department of Veterans Affairs Technology Acquisition Center Austin for EHRM Infrastructure Upgrade Construction at the Fort Meade VAMC. The opportunity type is listed as a solicitation for upgrading infrastructure at the Fort Meade VA Medical Center. No other salient details are provided in this document, as it appears to be an attachment consisting of a drawing without further specification of requirements, response timing, or other contract particulars.
View the file
Other files for this federal contract opportunity
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
O S
90-AE-201
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
NORTH
108 SF
TR
102A
RESEARCH OFFICE
EDUCATION
CLASSROOM
EDUCATION
CLASSROOM
SIMULATION LAB
STAIR 1
ST1
CORRIDOR
C102
STORAGE
111A
RESTROOM
RESTROOM
COMPUTER
EDUCATION
CLASSROOM
STORAGE
MECH ROOM
OFFICE
CORRIDOR
C103
VESTIBUILE
MECH. ROOM
KITCHEN
CORRIDOR
C101
RESTROOM
RESTROOM
OFFICE
107C
OFFICE
107B3
CONFERENCE
ROOM
107B
RECEPTIONIST
WORK AREA
VESTIBULE
107B2
OFFICE
107B1
OFFICE
107A
03-01
09-13
09-21
23-05
26-13
ROOM ALLOCATION LEGEND
PROPOSED NEW CABINET / TR / MCR LOCATION
EXISTING TR WITH POWER AND FIBER
UPGRADES, SEE TELECOM AND
ELECTRICAL DRAWINGS
ABANDONED ROOM
ROOM TO REMAIN, NO WORK
PROPOSED EXPANSION TO TR
REMODEL REQUIRED DUE TO EHRM IMPACT
FLOOR PLAN NOTES
1. SEE G SERIES SHEETS FOR BALANCE OF PLAN GENERAL NOTES.
2. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS
FOR ADDITIONAL INFORMATION. ALL INFORMATION REGARDING
EXISTING CONDITIONS IS BASED UPON OWNER-SUPPLIED
DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD CONDITIONS.
3. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND ALL
WALL MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE
LOCATIONS.
4. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE OF
STUD, UNLESS OTHERWISE NOTED.
5. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND
REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.
6. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO
PROVIDE SUITABLE SUBSTRATE FOR FINISHES.
7. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS REQUIRING ADA
ACCESS CONTROL.
8. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND
BOTTOM, AND PENETRATIONS, AND INSTALL PUTTY PADS AROUND
ELECTRICAL BOXES WHERE PARTITION CONTAINS ACOUSTICAL
INSULATION.
9. ALL TELECOMMUNICATION ROOMS ARE TO HAVE EXPOSED
STRUCTURE UNLESS NOTED OTHERWISE, NO CEILINGS SPECIFIED.
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
FLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
1. REFER TO ELECTRICAL SHEETS FOR FIXTURE TYPES, SWITCHING, AND
SPECIAL SYSTEMS.
2. REFER TO MECHANICAL SHEETS FOR DIFFUSER AND DUCTING LAYOUTS.
3. SEE SHEET 00-GI-006 FOR TYPICAL ACOUSTICAL PANEL CEILING DETAILS
REFLECTED CEILING PLAN NOTES
2x2 LIGHT FIXTURE
2x4 LIGHT FIXTURE
STRIP LIGHT FIXTURE
6" RECESSED CAN LIGHT FIXTURE
SUPPLY AIR DIFFUSER
RETURN AIR VENT
EXHAUST FAN
REFLECTED CEILING PLAN LEGEND
5/8" GYP. BOARD CEILING AFFIXED TO 3 5/8" MTL STUDS
2'x4' SUSPENDED ACOUSTIC CEILING TILE CEILING
GYP-1
ACT-2
2'x2' SUSPENDED ACOUSTIC CEILING TILE CEILINGACT-1
108 SF
TR
102A
9'
/8
90-AE-2011
90-109A.0
RESEARCH OFFICE
EDUCATION
CLASSROOM
EDUCATION
CLASSROOM
PAINT ENTIRE ROOM
09-04
09-19
09-09
09-06
26-02
26-03
26-04
09-07
06-01
06-01
06-01
09-18
09-18
09-10
09-10 06-01
E X
IS
T
IN
G
F
LO
O R
N E
W S
T A
T
IC
D
IS
. F
LO
O R
23-08
26-13
26-13
TR
102A
EDUCATION
CLASSROOM
RESEARCH OFFICE
EDUCATION
CLASSROOM
CORRIDOR
C101
ACT-1
8' - 0"
EXPOSED CEILING
GYP-1
9' - 6"
22-01
22-02
26-05
LEVEL 1
100' - 0"
TR
102A 8'
6"
06-01
09-01
09-18
26-05
E
LEVEL 1
100' - 0"
TR
102A 8'
6"
09-01
06-01
09-18
05-02
26-11
26-05
E
LEVEL 1
100' - 0"
TR
102A
EXISTING GYPSUM BOARD WALL, PAINT
06-01
09-18
09-01
E
26-05
LEVEL 1
100' - 0"
TR
102A
90-109A.0
26-04
06-01
09-01
09-18
E
S
26-05
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t
M e a d e S
D /2
B ld g r2
.r v t
-0
-2
:5
:3
90-AE-201
90-FLOOR PLANS AND
ELEVATIONSGDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 90
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/8" = 1'-0"5
90 - LEVEL 1 FLOOR PLAN
03-01 NEW HOUSEKEEPING PAD, COORDINATE WITH MECHANICAL DRAWINGS FOR SIZE AND CIVIL
DRAWINGS FOR DETAILS
05-02 SECURITY GRILL: 2" x 2" x 10GA WIRE MESH WELDED TO 1 1/2" x 1 1/4" x 13GA ROLL FORMED
ANGLE FRAME; PROVIDE 3" CLIPS, ANCHOR DIRECTLY ONTO EXISTING WALL; CONTRACTOR
TO VERIFY ACTUAL WINDOW SIZE PRIOR TO GRILL FABRICATION
06-01 INSTALL 3/4" AC GRADE OR BETTER FIRE RETARDANT PLYWOOD; PAINT WITH TWO COATS OF
SEMI-GLOSS BRIGHT WHITE FIRE RETARDANT PAINT; MOUNT BOTTOM OF PLYWOOD 6" A.F.F.,
TOP OF PLYWOOD AT 8'-6" A.F.F.
09-01 PAINT WALL ABOVE PLYWOOD WITH SEMI-GLOSS PAINT, COLOR TO MATCH PLYWOOD PAINT.
09-04 INFILL DOOR OPENING WITH WALL TYPE MATCHING ADJACENT, INSTALL TRIM & BASE TO
MATCH ADJACENT WALL
09-06 SEAL ALL WALL PENETRATIONS EXISTING AND NEW. PROVIDE APPROPRIATE FIRE RATED UL
HILTI DESIGNATION FOR PIPE AND/OR CONDUIT PENETERATIONS; SEE TYPICAL PENETRATION
DETAILS FOR RATED WALL CONDITIONS.
09-07 INSTALL STATIC DISSIPATIVE RESILIENT FLOORING
09-09 APPLY JOINT COMPOUND AND FEATHER A MINIMUM OF 3' HORIZONTALLY AS REQUIRED TO
ACHIEVE A SMOOTH AND UNIFORM APPEARANCE
09-10 PAINT FULL LENGTH OF WALL TO NEAREST EXTERIOR OR INTERIOR CORNER, COLOR TO
MATCH EXISTING WALLS.
09-13 FOLLOW EXISTING CABLE ROUTING FOR REMOVAL OF EXISTING CABLE AND INSTALLATION OF
NEW CABLES AT LOCATIONS AS NOTED IN TELECOM DRAWINGS.
09-18 6" HIGH COVED RUBBER WALL BASE, COLOR TO BE SELECTED FROM MANUFACTURER'S
STANDARD SELECTION
09-19 EXTEND GYPSUM BOARD WALL TO UNDERSIDE OF STRUCTURE WITH 5/8" GYPSUM BOARD
LAYER ON EACH SIDE OF WALL, SEAL
09-21 REMOVE AND RE-INSTALL CEILING TILES AND OTHER CEILING MOUNTED DEVICES AS NEEDED
FOR INSTALLATION OF CABLES AND CONDUITS ABOVE CEILING AS PER TELECOM DRAWINGS,
REPLACE ALL DAMANGED TILES TO MATCH EXISTING AND REINSTALL ALL DEVICES AS
NEEDED. DO NOT LEAVE CEILING TILES UNINSTALLED AND UNATTENDED PAST DURATION OF
WORKING SHIFT. CONTINUOUSLY REINSTALL TILES TO PROVIDE SEALED SMOKE ASSEMBLY.
22-01 FIRE SUPPRESSION SPRINKLER HEAD SHOWN FOR REFERENCE ONLY; FIRE SUPPRESSION
CONTRACTOR TO VERIFY ACTUAL QUANTITIES REQUIRED, INSTALL SYMMETRICALLY CENTER
IN TILE.
22-02 UPRIGHT HEAD FIRE SUPPRESSION SPRINKLER HEAD SHOWN FOR REFERENCE ONLY; FIRE
SUPPRESSION CONTRACTOR TO VERIFY ACTUAL QUANTITIES REQUIRED, COORDINATE
INSTALLATION WITH MEPT DRAWINGS
23-05 MECHANICAL UNITS, SEE MECH DRAWINGS FOR SIZE AND SPECS
23-08 NEW REFRIGERANT PIPE LINES ROUTING SHOWN FOR REFERENCE ONLY. SEE MECHANICAL
DRAWINGS FOR ACTUAL ROUTING; CONTRACTOR TO REMOVE CEILING TILES ALONG ROUTE
OUTSIDE OF TR'S AND REPLACE WITHIN WORKING SHIFT. CONDUCT INFECTION PREVENTION
MEASURES AS SPECIFIED.
26-02 3' PERIMETER CLEARANCE AROUND SERVER RACK SHOWN DASHED
26-03 TELECOMM RACK, SEE TELECOMMUNICATION DRAWINGS
26-04 ELECTRICAL PANELS, SEE ELECTRICAL DRAWINGS
26-05 CABLE TRAY, SEE TELECOMMUNICATION DRAWINGS
26-11 STROBE LIGHT, SEE ELECTRICAL DRAWINGS
26-13 NEW CABLE TRAY ROUTING SHOWN FOR REFERENCE ONLY. SEE TELECOMMUNICATION
DRAWINGS FOR ACTUAL ROUTING. CONDUCT INFECTION PREVENTION MEASURES AS
SPECIFIED.
1/2" = 1'-0"6
90 - 109A ENLARGED PLAN
1/4" = 1'-0"7
LEVEL 1 - ENLARGED RCP
1/2" = 1'-0"4
90 - TR109A EAST ELEVATION
1/2" = 1'-0"3
90 - TR 109A NORTH ELEVATION
1/2" = 1'-0"2
90 - TR 109A SOUTH ELEVATION
1/2" = 1'-0"1
90 - TR 109A WEST ELEVATION
KEY NOTES
Revisions: Date:
AA
EE
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
NORTH
BB
CC
DD
26-09
13-01
01-01
26-10
ENTRY
OFFICE
09-13
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
FLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
STRIP LIGHT FIXTURE, REF ELEC DRAWINGS
FLOOR PLAN NOTES
1. SEE G SERIES SHEETS FOR BALANCE OF FLOOR PLAN GENERAL NOTES.
2. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION. ALL INFORMATION REGARDING EXISTING
CONDITIONS IS BASED UPON OWNER-SUPPLIED DOCUMENTS AND MAY NOT
PRECISELY REFLECT FIELD CONDITIONS.
3. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND ALL WALL
MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE LOCATIONS.
4. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE OF STUD,
UNLESS OTHERWISE NOTED.
5. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND REPAIR ALL
INCONSISTENCIES IN FLOOR ELEVATIONS.
6. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO PROVIDE
SUITABLE SUBSTRATE FOR FINISHES.
7. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS REQUIRING ADA
ACCESS CONTROL.
8. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND BOTTOM,
AND PENETRATIONS, AND INSTALL PUTTY PADS AROUND ELECTRICAL
BOXES WHERE PARTITION CONTAINS ACOUSTICAL INSULATION.
9. ALL TELECOMMUNICATION ROOMS ARE TO HAVE EXPOSED STRUCTURE
UNLESS NOTED OTHERWISE, NO CEILINGS SPECIFIED.
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t M e a d e
S D
/2
B ld g r2
.r v t
-0
-2
:1
:5
110-AE-201
110-FLOOR PLANS
GDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 110
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/8" = 1'-0"1
LEVEL 1 FLOOR PLAN
01-01 CLEAN UP AREA AROUND PROPOSED WALL MOUNTED CABINET LOCATION;
COORDINATE WITH C.O.R. FOR RELOCATION OR REMOVAL OF INSTALLATION
OBSTRUCTING ITEMS.
09-13 FOLLOW EXISTING CABLE ROUTING FOR REMOVAL OF EXISTING CABLE AND
INSTALLATION OF NEW CABLES AT LOCATIONS AS NOTED IN TELECOM
DRAWINGS.
13-01 ICRA CLASS I, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND
WORKING HOURS RESTRICTIONS
26-09 30" CLEARANCE AT WALL MOUNTED SERVER RACK SHOWN DASHED
26-10 WALL MOUNTED TELECOM CABINET, SEE TELECOM DRAWINGS
KEYNOTES
UP
113-AE-301
NORTH
SCALE: 1/16" = 1'-0"
16' 12' 8' 4' 16' 32'0'
TR
B01
LOGISTICS
STORAGE
B02A
BIOMED SERVER
B29
HAZARDOUS
WASTE STORAGE
B29
PHARMACY
RECEIVING/ HAZ.
DRUG STORAGE
B39
CLOSET
TCBA
EXIT STAIRS
STBA
BREAK ROOM
B28A
ELECTRICAL
SWITCHGEAR
B14B
SPS WOMEN'S
LOCKER RM.
B09A
OFFICE
B04A
STERILE
HAZARDOUS
BUFFER (PHHD1)
B38
STORAGE
B41
STERILE
NON-HAZARDOUS
BUFFER (PHSC1)
B36
ANTE (PHAR1)
B37
HSK CLOSET
B17
MECHANICAL
ROOM
MB100
HAZ DRUG
STOR/NON-STERILE
HD COMPOUNDING
(PHNIS1)
VEST
B18
STORAGE
B18C
HCBB
ECBC
BMET OFFICE
WORKROOM
B20
VEST
B19D
BODY COOLER
B19
STORAGE
B19.2
STORAGE
B19.1
STORAGE
MBB
MECH ROOM
B21
CRAWL SPACE
CSB3
BMET OFFICE
B24A
STORAGE
HCBB
CRAWL SPACE
STORAGE
B09
ETO EQUIP. ROOM
MBA
EXIT STAIRWALL
BA0.1
ELECTRICAL
EQUIPMENT
ECS002
ELEVATOR
EQUIPMENT
ECS002A
ECBA
ECBA
HALL
CS001
MECHANICAL
ROOM
BA0
HAC
S004
CRAWL SPACE
CSB5
CRAWL SPACE
CSB4
MORGUE
B18B
LOGISTICS OFFICE
B26
LOGISTICS OFFICE
B27
PHARMACY
STORAGE
B27A
VEST
B07
MAINT SHOP /
MECH. ROOM
MBC
VEST
B23
VEST
B22
STAIR
STBD
BMET STORAGE
B24
MECH ROOM
B25
VEST
B32
CRAWL SPACE
CSB7
MECH
B34
STORAGE
B35
STORAGE
HCBC
ROOM
B30
LOGISTICS
STORAGE OFFICE
B02
LAUNDRY CHUTE
TERMINATION
ROOM
B03
CRAWL SPACE
CSB2
CRAWL SPACE
CSB1
CRAWL SPACE
CSB10
CRAWL SPACE
CSB7
CRAWL SPACE
CSB9
LOGISTIC
STORAGE
B04
SPS DIRTY
PROCESSING
B08
VEST
B11
SCOPE
PROCESSING
B11A
SPS BREAK ROOM
B10
STORAGE
ECBB
LOCKSMITH WORK
ROOM
B14A
COMP. GAS
STORAGE
B13
INFECTIONS
WASTE STO
B11B
HAZMAT STO
B12
SPS MEN'S LOCKER
RM.
B18A
SPS STERILE
PROCESSING
B05
EXIST STAIRWALL
BA1
ELEVATOR
B15
ELEVATOR
B16
LOBBY
B14
BMET OFFICE /
WORKROOM
B28
SPS CART WASH
B06A
LOADING DOCK
LD1
STORAGE
HCBA
EXIT STAIRWELL
B22B
MEZZANINE
B25.1
CRAWL SPACE
CSB6
FILLING/ASSEMBLY
INPATIENT (PHIF1)
B30B
CRAWL SPACE
CSB8A
ELEV
S003
PROPOSED NEW CABINET / TR / MCR LOCATION
EXISTING TR WITH POWER AND FIBER
UPGRADES, SEE TELECOM AND
ELECTRICAL DRAWINGS
ROOM ALLOCATION LEGEND
ABANDONED ROOM
ROOM TO REMAIN, NO WORK
PROPOSED EXPANSION TO TR
REMODEL REQUIRED DUE TO EHRM IMPACT
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
1-HOUR FIRE WALL
LIFE SAFETY LEGEND
2-HOUR FIRE WALL
1-HOUR FIRE/SMOKE WALL
SMOKE RESISTIVE HAZARDOUS AREA
FLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
STRIP LIGHT FIXTURE, REF ELEC DRAWINGS
FLOOR PLAN NOTES
1. SEE G SERIES SHEETS FOR BALANCE OF PLAN GENERAL NOTES.
2. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION. ALL INFORMATION
REGARDING EXISTING CONDITIONS IS BASED UPON OWNER-
SUPPLIED DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD
CONDITIONS.
3. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND
ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE
LOCATIONS.
4. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE
OF STUD, UNLESS OTHERWISE NOTED.
5. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND
REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.
6. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO
PROVIDE SUITABLE SUBSTRATE FOR FINISHES.
7. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS REQUIRING
ADA ACCESS CONTROL.
8. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND
BOTTOM, AND PENETRATIONS, AND INSTALL PUTTY PADS
AROUND ELECTRICAL BOXES WHERE PARTITION CONTAINS
ACOUSTICAL INSULATION.
9. ALL TELECOMMUNICATION ROOMS ARE TO HAVE EXPOSED
STRUCTURE UNLESS NOTED OTHERWISE, NO CEILINGS
SPECIFIED.
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t M e a d e
S D
/2
B ld g r2
.r v t
-0
-2
:1
:0
113-AE-200
113-BASEMENT FLOOR PLAN
GDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 113
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/16" = 1'-0"1
BASEMENT FLOOR PLAN
J
J J
113-AE-303
113-AE-302
113-AE-302
NORTH
SCALE: 1/16" = 1'-0"
16' 12' 8' 4' 16' 32'0'
126 SF
TR
192A
CLOSET
TC1A
ELEC
ROOM
EC1F
BIOMED SERVER
EC1E
C-PAP
TR
CLOSET
STORAGE
ELEC
EC1C
TR
TCS103
BIO MED
S104
CORRIDOR
CS101
SECURITY
SCS102
OFFICE
182I
EXAM
182H
EXAM
182E
PHARMACY
OFFICE/ EXAM
EXAM
182R
EXAM
182S
HSK CLOSET
182V
SOILED UTILITY
182W
ROOM
B04J
ICU BED
ICU BED
STEAM TRAP ROOM
S115
MENS TOILET &
SHOWER, STAFF
S133
ANTE ROOM
S134
WOMENS TOILET &
SHOWER, STAFF
S135
CUBICLE,
CLERICAL STAFF
S112
OFFICE, ASSIST.
SPS CHIEF
S113
ANTE ROOM
S114
VAULT RX
191A
VEST
101A
189F
RECEIVING
191B
AUDIOLOGY
188M
STORAGE
188K
EXAM
188L
WORK ROOM
188J
CORRIDOR
191C
CONFERENCE
191E
EXAM
182C
EMPLOYEE HEALTH
OFFICE
STRG
178B
EXAM
182G
EXAM
182F
RESTROOM
RESTROOM
STORAGE
171A
ECHO
171B
RESTROOM
128D
STORAGE
148J
ADMIN AREA
BREAK RM
152TOILET
HSK CLOSET
STORAGE
CLOSET
164A
X-RAY
C-PAP LOCKER
ROOM
168B
READING ROOM
NUC MED OFFICE
OFFICE
WOMEN'S
174A
STORAGE
HC1B
HOT LAB
STORAGE
148K
IMAGE FILE
STORAGE
BATHROOM
147.1
STORAGE
148B
BATHROOM
148C
BATHROOM
142A
STORAGE
VEST
C.T. SCANNER
148E
VIEWING ROOM
148H
NUCLEAR
MEDICINE
STORAGE
172A
ORTHO DOC
OFFICE x3
ECHO CLINIC
ANTI-COAG
PATIENT CONSULT
176A
PHARMACY ADMIN
AREA
176D
OFFICE
176E
OFFICE
176F
OFFICE
176H
OFFICE
176G
EXAM ROOM
189D EXAM ROOM
189C
EXAM ROOM
189A
EXAM
188E
EXAM
188D
EXAM
188I
BATHROOM
188BEXAM ROOM
OFFICE
188N
EXAM ROOM
189B
OFFICE
189E
VESTIBULE
C100DA
EXAM
183C
DOCTOR OFFICE
NUTRITIONIST
OFFICE
EXAM
183H
EXAM
183F
DOC OFFICE (x2)
183I
TOILET
182M
TOILET
182N
CLEAN UTILITY
187H
EXAM
187G
MED ROOM
187K
TOILET
187J
MED ROOM
187F
MED ROOM
187DA
OBSERVATION
ROOM
187Q
OFFICE
187P
OBSERVATION
ROOM
187S
WORK ROOM
188C.1
ROOM
B04.0
OFFICE
183.1
EXAM
182T
EXAM
188H
EXAM
188F
BREAK ROOM
188G
VEST
C100RA
OFFICE X2
183L
N.M. OFFICE (x2)
183K
DERM OFFICE (x2)
183JA
OPEN OFFICE
183J
DOC OFFICE
183N
PSYC OFFICE
183M
TOILET
1830A
EXIT STARIS
STCS1
EXAM
183S
EXAM
183P
MOD ROOM
OFFICE
OFFICE
CONFERENCE
ROOM
S146
WOMEN'S TOILET
S139
VEST
188A
HSK
122A
BATHROOM
119C
STORAGE
EC1A1
MED ROOM
119A
BATHROOM
130B
BATHROOM
135D
VEST
WORK ROOM
135C
BREAK ROOM
OFFICE
SUPERVISOR
OFFICE
ANCILLARY
TESTING
BLOOD DRAW
DEXA SCANNER
DETERGENT AND
WATER
TREATMENT ROOM
S119
WOMENS
S121
STEAM
STERILIZERS
S131
MEDIVATOR ROOM
S130
HAC
S120
STERILE
S118
NOUR.
BREAK ROOM
119B
EXIT STAIRS
ST1A
GEN ROOM
143.1
CONROL
145B
VIEWING ROOM
VEST
148A
HOME OXYGEN
OFFICE
171C
EKG ROOM
ANTI-COAG
PATIENT CONSULT
176B
SOCIAL WORKER
182P
EXAM
182Q
OFFICE
182U
CORRIDOR
C100G
VETERAN
PREFERENTIAL
TREATMENT (VPT)
182L
OFFICE X3
182X
OBSERVATION
ROOM
187R
WOMEN'S
101B
MEN'S TOILET
S140
SOIL
ADMIN. SWING
SPACE
S142
PATIENT SERVICES
S141
ICU BED
ISOLATION ROOM
STAFF MEN'S
RESTROOM
PREPARATION,
ASSEMBLY, AND
STERILIZATION
S132
SOILED
TRANSITION ROOM
S122
VESTIBULE B
S152
CONFERENCE
ROOM/
S149
OFFICE, SPS CHIEF
S150
AIR HANDLER
S151
LCKR ROOM
S147
LCKR ROOM
S148
SOILED ELEVATOR
S110
STAIRS
STS109
STAIRS
STS108
EXIST STAIRS
BA1
OFFICE
OFFICE
OFFICE
CORRIDOR
C102
LAUNDRY CHUTE
TERMINATION
ROOM
CHEMO. HOOD
ROOM
128G
OFFICE (AO OF
IMAGING)
168A
STORAGE
READING ROOM
NUC MED EXAM RM
WAITING ROOM
EXIT STAIRS
ST1D
STORAGE
187P.1
SOILED UTILITY
AMBULANCE
VESTIBULE
C100OA
NOURISHMENT
CENTER
187N
BREAK ROOM
187M
CORRIDOR
C100Q
LIFE SUPPORT
ROOM
187L
STORAGE
EC1G
HSK
TOILET
187C
TOILET
187B
OFFICE
187A
CORRIDOR
184.0
WAITING
BREAK ROOM
182J
EXIT STAIRS
ST1C
EXAM
TOILET
178A
CORRIDOR
C100E
WAITING ROOM
RECEPTION AREA
188A
VEST
OFFICE
CONFERENCE
ROOM / V-TEL
175A
RESPIRATORY
THERAPY
STORAGE
173A
RESP THERAPY
CONFERENCE/
BREAK ROOM
EXIT STAIR
ST1B
VESTIBULE
PULMONARY
FUNCTION
123B
MEN'S
101C
ELEC CLOSET
EC1A
RESPIRATORY
THERAPY
123A
OFFICE
EQUIPMENT
STORAGE
112A
CLEAN
112B
NURSES STATION
ICU BED
CORRIDOR
NURSE MANAGER
OFFICE
STORAGE
HC1A
MECH. ROOM
M100
ELECTRICAL /
MECHANICAL
MCS111
VESTIBULE A
S124
HAC
S126
MENS
S123
DECONTAMINATION
S127
ELEVATOR EQPMT
S125
HAC
S106
VEST
177A
CORRIDOR
EXAM
183Q
EXAM
183G
EXAM
183E
DERM EXAM
183D
MED ROOM
183U
CLEAN UTILITY
183T
EXAM
183R
VEST
135B
PATHOLOGY
135A
BLOOD BANK
138.1
CHEMOTHERAPY
AREA
128F
CHEMOTHERAPY
AREA
128E
VEST
CHEMOTHERAPY
AREA
128C
CHEMOTHERAPY
AREA
128B
CHEMOTHERAPY
AREA
128A
WAITING ROOM
C104A
VEST
C104
VEST
X-RAY
CONROL
145A
X-RAY
CONTROL AREA
148F
PATIENT
148I
ULTRA SOUND
148D
CONF
182K
URGENT CARE
C100P
NURSES STATION
187I
CORRIDOR
NURSES STATION
188C
CLERK
188A.1NURSES STATION
EXAM
189M
SPECIAL
PROCEDURE
189L
SPECIAL
PROCEDURE
189K
PHARMACY
WAITING
EXAM
189J
SOIL
189I
TOILET
189GA
EXAM ROOM
189G
CLEAN
189H
CORRIDOR
188P
PHARMACY
WAITING
BUSINESS OFFICE
ROI
102/103
CORRIDOR
CS108
AUTOMATIC CART
S128
CART UNLOADING
S129
SWING SPACE
S143
WORKSTATION
S116
EXIST STAIRS
1A1
INTENSIVE CARE
UNIT
C100C
STORAGE
ICU FAMILY
WAITING ROOM
03-01
113-AE-302
CASHIERS
09-13
26-13
02-31
PROPOSED NEW CABINET / TR / MCR LOCATION
EXISTING TR WITH POWER AND FIBER
UPGRADES, SEE TELECOM AND
ELECTRICAL DRAWINGS
ROOM ALLOCATION LEGEND
ABANDONED ROOM
ROOM TO REMAIN, NO WORK
PROPOSED EXPANSION TO TR
REMODEL REQUIRED DUE TO EHRM IMPACT
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLANFLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
STRIP LIGHT FIXTURE, REF ELEC DRAWINGS
FLOOR PLAN NOTES
1. SEE G SERIES SHEETS FOR BALANCE OF PLAN GENERAL NOTES.
2. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION. ALL INFORMATION
REGARDING EXISTING CONDITIONS IS BASED UPON OWNER-
SUPPLIED DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD
CONDITIONS.
3. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND
ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE
LOCATIONS.
4. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE
OF STUD, UNLESS OTHERWISE NOTED.
5. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND
REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.
6. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO
PROVIDE SUITABLE SUBSTRATE FOR FINISHES.
7. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS REQUIRING
ADA ACCESS CONTROL.
8. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND
BOTTOM, AND PENETRATIONS, AND INSTALL PUTTY PADS
AROUND ELECTRICAL BOXES WHERE PARTITION CONTAINS
ACOUSTICAL INSULATION.
9. ALL TELECOMMUNICATION ROOMS ARE TO HAVE EXPOSED
STRUCTURE UNLESS NOTED OTHERWISE, NO CEILINGS
SPECIFIED.
1-HOUR FIRE WALL
LIFE SAFETY LEGEND
2-HOUR FIRE WALL
1-HOUR FIRE/SMOKE WALL
SMOKE RESISTIVE HAZARDOUS AREA
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t M e a d e
S D
/2
B ld g r2
.r v t
-0
-2
:1
:0
113-AE-201
113-LEVEL 1 FLOOR PLAN
GDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 113
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/16" = 1'-0"1
FIRST FLOOR PLAN
02-31 SEE TELECOM PLANS FOR PATH LOCATION. PREP CEILING FOR SURFACE
MOUNT CONDUIT IN LOCATIONS W/O ACOUSTIC CEILING TILES.
03-01 NEW HOUSEKEEPING PAD, COORDINATE WITH MECHANICAL DRAWINGS FOR
SIZE AND CIVIL DRAWINGS FOR DETAILS
09-13 FOLLOW EXISTING CABLE ROUTING FOR REMOVAL OF EXISTING CABLE AND
INSTALLATION OF NEW CABLES AT LOCATIONS AS NOTED IN TELECOM
DRAWINGS.
26-13
NORTH
SCALE: 1/16" = 1'-0"
16' 12' 8' 4' 16' 32'0'
CONVERSION OF THIS
SPACE INTO NEW TR NOT
UNDER THIS CONTRACT
CONTRACT WORK SHOWN GRAY UNDER
SEPARATE PROJECT
CONTRACT WORK UNDER EHRM PROJECT 568-21-701
ELEVATOR
ELEVATOR
SUPPLY
EXCHANGE
NURSE
MANAGER
(ICU/MED-
SURG)
CLEAN STORAGE
207A
STORAGE
CLEAN
UTILITY
PATIENT ROOM
RESTROOM
250A
PATIENTROOM
MED ROOM
LOGISTICS
STORAGE
MID-LEVEL
OFFICE X2
DOCTOR
OFFICE X2
WAITING
ROOM
STORAGE
SURGERY
ADMIN.
OFFICER
OFFICE
SOCIAL
WORKER
OFFICE
RR
262AVACATED
SURGICAL
RECOVERY AREA
HSK CLOSET
PATIENT ROOM
PATIENT
PATIENT ROOM
RR
268A
RR
MED SURG NURSE
MANAGER OFFICE
PATIENT ROOM
PATIENT ROOM
RR
272A
RR
269A
RR
270A
RR
262B
RR
268B
RESTROOM
254A
CONFERENCE
ROOM
MED/SURG
EQUIP
STORAGE
EMS STORAGE
PT STORAGE
HSK
CLOSET
RESTROOM
EMS
STORAGE
RESTROOM
232A
RESTROOM
RESTROOM
242A
RESTROOM
243A
RESTROOM
228A
TOILET
TOILET
220A
TOILET
222A
SPECIAL
PROCEDURE
SOILED UTILITY
S225D
CLEAN
ELEVATOR
S234
TOILET
207D
VACATED OFFICE
207C
UTILITY
207B
EXIT STAIR
ST2D
HAC
WORK STATION
ADMIN
SOILED UTILITY
CLEAN UTILITY
SCOPE DECONTAM.
SCOPE
REPROCESSING
ANTE ROOM
GI/
BRONCHOSCOPY
GI/
BRONCHOSCOPY
OFFICE (CHIEF
OF SURGERY)
HAC
S228
WOMEN'S TOILET
ROOM
S223E
VESTIBULE
S223
CORRIDOR
CS201F
PATIENT
SPACE
S215
PATIENT
SPACE
S213
PATIENT
SPACE
S211
PATIENT
SPACE
S209
PATIENT
SPACE
S207
PATIENT
SPACE
S205
PATIENT
SPACE
S203
PATIENT
SPACE
S201
PATIENT
SPACE
S212
PATIENT
SPACE
S214
LINEN ALCOVE
ENDOSCOPY
RESTROOM
226A
CORRIDOR
EXIT STAIRS
ST2B
ELEC CLOSET
EC2D
LOCKER ROOM
256C
LOCKER
ROOM
256B
RR
271A CORRIDOR
C200F1
BREAK ROOM
CORRIDOR
256A
CORRIDOR
C200F
ROOM
NURSE STATION
CLEAN UTILITY
NOURISHMENT
CENTER
C200D
RESTROOM
251A
PATIENT ROOM
PATIENT ROOM
CLOSET
HC2C
EXIT STAIRS
ST2C
STORAGE
STERILE SUPPLY
EQUIP.
STORAGE
RR
280A
RR
RR
CORRIDOR
C200D
PATIENT ROOM
RESTROOM
245A
LOGISTIC OFFICE
X2
PATIENT ROOM
GROUP PRACTICE
MANAGER
DOCTOR OFFICE X2
RSTROOM
244A
CHARTING
ROOM
242.5
SOILET
UTILITY
OFFICE X4
HOSPITALIST
& PHARMACY
OXYGEN
STORAGE
ELEC
ROOM
EC2C
LINEN
CLOSET
RESTROOM
229A
PATEINT ROOM
BARIATRIC
SHOWER /
RESTROOM
CORRIDOR
C201
CORRIDOR
C200B
VACATED P.A.C.U.
RECOVERY ROOM
DIRTY STORAGE
CORRIDOR
CS201A
PATIENT
TOILET
S204
CLEAN
UTILITY
S208
SOILED
UTILITY
S206
MEDS
S210A
NURSES
STATION
S210
PATIENT
TOILET
S216
BIO-MED
SPACE
S220
CHIEF OF
SURGERY
OFFICE
S219
PATIENT
SPACE
S217
CONTROL
ROOM
S218
PATIENT
TOILET
S225A
CLEAN UTILITY
S225E
NURSES STATION
S225C
CORRIDOR
CS201B
STAFF AREA
S223B
MEN'S LOCKER
ROOM
S223D
WOMEN'S LOCKER
ROOM
S223C
NURSES STATION
S223
OR NURSE
MANAGER OFFICE
S236
ANESTHESIA
OFFICE X4
S234
TELECOM/ELECTRICAL
TSC221
P.A.C.U
S225
SURGERY ROOM #2
S224
SURGERY ROOM #1
S222
SUB-STERILE
ROOM
S222A
HAC
S237
SOILED ELEVATOR
S239
SOILED HOLD &
DISPOSAL AREA
S238
STAIR
STS241
MEDICAL GASES
S240
HALL
CS201I
HALL
CS201H
SUB-STERILE
ROOM
S226A
SURGERY ROOM #3
S226
ANESTHESIA WORK
& EQUIPMENT
S227
VESTIBULE
S223J
SHOWER
S223H
MEN'S TOILET
ROOM
S223G
ELEC SPACE
ECS232
STAIR
STS231
CLEAN & STERILE
SUPPLY
S229
EQUIPMENT
STORAGE
S230
CORRIDOR
CS201C
CORRIDOR
CS201E
SPECIAL
PROCEDURE
TOILET
UV
TREATMENT
ROOM X4
CORRIDOR
C200A1
SWING
OFFICE
HALL
CS201G
EYE WASH
208A
CONSULT
RECEPTION
CLOSET
TC2A
CLOSET
EC2B
NOURISHMENT
PATIENT ROOM
09-13
02-31
26-13
PROPOSED NEW CABINET / TR / MCR LOCATION
EXISTING TR WITH POWER AND FIBER
UPGRADES, SEE TELECOM AND
ELECTRICAL DRAWINGS
ROOM ALLOCATION LEGEND
ABANDONED ROOM
ROOM TO REMAIN, NO WORK
PROPOSED EXPANSION TO TR
REMODEL REQUIRED DUE TO EHRM IMPACT
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
FLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
STRIP LIGHT FIXTURE, REF ELEC DRAWINGS
FLOOR PLAN NOTES
1. SEE G SERIES SHEETS FOR BALANCE OF PLAN GENERAL NOTES.
2. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION. ALL INFORMATION
REGARDING EXISTING CONDITIONS IS BASED UPON OWNER-
SUPPLIED DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD
CONDITIONS.
3. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND
ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE
LOCATIONS.
4. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE
OF STUD, UNLESS OTHERWISE NOTED.
5. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND
REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.
6. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO
PROVIDE SUITABLE SUBSTRATE FOR FINISHES.
7. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS REQUIRING
ADA ACCESS CONTROL.
8. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND
BOTTOM, AND PENETRATIONS, AND INSTALL PUTTY PADS
AROUND ELECTRICAL BOXES WHERE PARTITION CONTAINS
ACOUSTICAL INSULATION.
9. ALL TELECOMMUNICATION ROOMS ARE TO HAVE EXPOSED
STRUCTURE UNLESS NOTED OTHERWISE, NO CEILINGS
SPECIFIED.
1-HOUR FIRE WALL
LIFE SAFETY LEGEND
2-HOUR FIRE WALL
1-HOUR FIRE/SMOKE WALL
SMOKE RESISTIVE HAZARDOUS AREA
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t M e a d e
S D
/2
B ld g r2
.r v t
-0
-2
:1
:0
113-AE-202
113-LEVEL 2 FLOOR PLAN
GDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 113
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/16" = 1'-0"1
SECOND FLOOR PLAN
02-31 SEE TELECOM PLANS FOR PATH LOCATION. PREP CEILING FOR SURFACE
MOUNT CONDUIT IN LOCATIONS W/O ACOUSTIC CEILING TILES.
09-13 FOLLOW EXISTING CABLE ROUTING FOR REMOVAL OF EXISTING CABLE AND
INSTALLATION OF NEW CABLES AT LOCATIONS AS NOTED IN TELECOM
DRAWINGS.
26-13
OS
11' - 9"
95 SF
TR
B01
LOGISTICS
STORAGE
B02A
HAZARDOUS
WASTE STORAGE
B29
PHARMACY
RECEIVING/ HAZ.
DRUG STORAGE
B39
113-AE-301 18
3-
B
.0
26-03
06-01
06-02
06-01
09-09
09-10
09-19
A-3
09-07
23-08
SCALE: 1/2" = 1'-0"
24" 18" 12" 6" 24" 48"0"
NORTH
08-03
09-18
09-06
8'
6' - 0"
A-3
A-3
A-3
A R
E A
O F
W E
T P
IP
E
S
EXTEND WALLS TO
UNDERSIDE OF DECK
EXTEND WALL AS PER TR ELEVATION DETAIL
LEVEL 1
100' - 0"
BASEMENT
88' - 0"
TR
B01
113-B01.0
09-01
09-18
26-05
26-04
E
S
6" METAL STUD AT 16" O.C.
SLOPED AT 1/4":12"
3/4" FIRE RATED PLYWOOD5/8" TYPE 'X' GYPSUM BOARD
WITH EPOXY PAINT
BASEMENT
88' - 0"
TR
B01
06-01
09-01
09-18
26-05
26-12 E
LEVEL 1
100' - 0"
BASEMENT
88' - 0"
TR
B01 8'
6"
06-01
09-01
09-18
26-12
26-11
E
26-05
6"
LEVEL 1
100' - 0"
BASEMENT
88' - 0"
TR
B01
06-01
09-01
09-18
26-12 E
26-05
FLOOR PLAN NOTES
1. SEE G SERIES SHEETS FOR BALANCE OF PLAN GENERAL NOTES.
2. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION. ALL INFORMATION
REGARDING EXISTING CONDITIONS IS BASED UPON OWNER-
SUPPLIED DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD
CONDITIONS.
3. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND
ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE
LOCATIONS.
4. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE
OF STUD, UNLESS OTHERWISE NOTED.
5. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND
REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.
6. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO
PROVIDE SUITABLE SUBSTRATE FOR FINISHES.
7. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS REQUIRING
ADA ACCESS CONTROL.
8. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND
BOTTOM, AND PENETRATIONS, AND INSTALL PUTTY PADS
AROUND ELECTRICAL BOXES WHERE PARTITION CONTAINS
ACOUSTICAL INSULATION.
9. ALL TELECOMMUNICATION ROOMS ARE TO HAVE EXPOSED
STRUCTURE UNLESS NOTED OTHERWISE, NO CEILINGS
SPECIFIED.
FLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
STRIP LIGHT FIXTURE, REF ELEC DRAWINGS
1. REFER TO ELECTRICAL SHEETS FOR FIXTURE TYPES,
SWITCHING, AND SPECIAL SYSTEMS.
2. REFER TO MECHANICAL SHEETS FOR DIFFUSER AND DUCTING
LAYOUTS
3. SEE SHEET 00-GI-006 FOR TYPICAL ACOUSTICAL PANEL CEILING
DETAILS
REFLECTED CEILING PLAN NOTES
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
LOGISTICS
STORAGE
B02A
TR
B01
HAZARDOUS
WASTE STORAGE
B29
PHARMACY
RECEIVING/ HAZ.
DRUG STORAGE
B39
CORRIDOR
BC01
SCALE: 1/4" = 1'-0"
4' 3' 2' 1' 4' 8'0'
NORTH
02-08 02-08
RELOCATE FIRE SUPPRESSION
HEADS IF FOUND TO BE LESS
THAN 4" FROM FACE OF NEW
GYPSUM BOARD WALL
MAINTAIN FULL ACCESS TO CRAWL
SPACE ACCESS DOOR
GYPSUM BOARD BULKHEAD
7'-6" A.F.F.
ACT-1
8' - 0"
SLOPED CEILING,SEE
ELEVATION DETAIL
23-05
22-01
22-01
1/4" / 12"
8' - 6" 8' - 3 1/8"
2x2 LIGHT FIXTURE
2x4 LIGHT FIXTURE
STRIP LIGHT FIXTURE
6" RECESSED CAN LIGHT FIXTURE
SUPPLY AIR DIFFUSER
RETURN AIR VENT
EXHAUST FAN
5/8" GYP. BOARD CEILING AFFIXED TO 3 5/8" MTL STUDS
2'x4' SUSPENDED ACOUSTIC CEILING TILE CEILING
GYP-1
ACT-2
REFLECTED CEILING PLAN LEGEND
2'x2' SUSPENDED ACOUSTIC CEILING TILE CEILINGACT-1
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t M e a d e
S D
/2
B ld g r2
.r v t
-0
-2
:1
:1
113-AE-301
113-ENLARGED PLANS AND
ELEVATIONSGDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 113
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
02-08 CAREFULLY REMOVE CEILING TILES AND OTHER CEILING MOUNTED
DEVICES, CAREFULLY STORE IN NON-TRAFFICKED AREA AND PREPARE FOR
REINSTALLATION AT COMPLETION OF WORK
06-01 INSTALL 3/4" AC GRADE OR BETTER FIRE RETARDANT PLYWOOD; PAINT WITH
TWO COATS OF SEMI-GLOSS BRIGHT WHITE FIRE RETARDANT PAINT; MOUNT
BOTTOM OF PLYWOOD 6" A.F.F., TOP OF PLYWOOD AT 8'-6" A.F.F.; DO NOT
PAINT OVER STAMPED PLYWOOD RATING
06-02 ALIGN PLYWOOD AT EDGE OF STEEL CHANEL, SEE STRUCTURAL DRAWINGS
FOR CHANEL DETAILS
08-03 ADA DOOR CLEARANCES SHOWN DASHED
09-01 PAINT WALL ABOVE PLYWOOD WITH SEMI-GLOSS PAINT, COLOR TO MATCH
PLYWOOD PAINT.
09-06 SEAL ALL WALL PENETRATIONS EXISTING AND NEW. PROVIDE APPROPRIATE
FIRE RATED UL HILTI DESIGNATION FOR PIPE AND/OR CONDUIT
PENETERATIONS; SEE TYPICAL PENETRATION DETAILS FOR RATED WALL
CONDITIONS.
09-07 INSTALL STATIC DISSIPATIVE RESILIENT FLOORING
09-09 APPLY JOINT COMPOUND AND FEATHER A MINIMUM OF 3' HORIZONTALLY AS
REQUIRED TO ACHIEVE A SMOOTH AND UNIFORM APPEARANCE
09-10 PAINT FULL LENGTH OF WALL TO NEAREST EXTERIOR OR INTERIOR
CORNER, COLOR TO MATCH EXISTING WALLS.
09-18 6" HIGH COVED RUBBER WALL BASE, COLOR TO BE SELECTED FROM
MANUFACTURER'S STANDARD SELECTION
09-19 EXTEND GYPSUM BOARD WALL TO UNDERSIDE OF STRUCTURE WITH 5/8"
GYPSUM BOARD LAYER ON EACH SIDE OF WALL, SEAL
22-01 FIRE SUPPRESSION SPRINKLER HEAD SHOWN FOR REFERENCE ONLY; FIRE
SUPPRESSION CONTRACTOR TO VERIFY ACTUAL QUANTITIES REQUIRED,
INSTALL SYMMETRICALLY CENTER IN TILE.
23-05 MECHANICAL UNITS, SEE MECH DRAWINGS FOR SIZE AND SPECS
23-08 NEW REFRIGERANT PIPE LINES ROUTING SHOWN FOR REFERENCE ONLY.
SEE MECHANICAL DRAWINGS FOR ACTUAL ROUTING; CONTRACTOR TO
REMOVE CEILING TILES ALONG ROUTE OUTSIDE OF TR'S AND REPLACE
WITHIN WORKING SHIFT. CONDUCT INFECTION PREVENTION MEASURES AS
SPECIFIED.
26-03 TELECOMM RACK, SEE TELECOMMUNICATION DRAWINGS
26-04 ELECTRICAL PANELS, SEE ELECTRICAL DRAWINGS
26-11 STROBE LIGHT, SEE ELECTRICAL DRAWINGS
26-12 ELECTRICAL OUTLETS MOUNTED ON PLYWOOD
1/2" = 1'-0"1
113 - B02A ENLARGED PLAN
KEY NOTES1/2" = 1'-0"16
TR B01 EAST ELEVATION
1/2" = 1'-0"17
TR B01 NORTH ELEVATION
1/2" = 1'-0"18
TR B01 SOUTH ELEVATION
1/2" = 1'-0"19
TR B01 WEST ELEVATION
1/4" = 1'-0"4
113 - B01 ENLARGED REFLECTED CEILING PLAN
126 SF
TR
192A
113-192.0
113-AE-302
26-04
3-
2.
26-02
26-03
06-01
06-01
06-01
06-01
09-11 09-07
09-02
09-03
10' - 2"
A-3
EXIST. COLUMN
EXIST. FLOOR
STATIC DES. FLOOR
CASHIERS
09-29
PLAN
NORTH
SCALE: 1/2" = 1'-0"
24" 18" 12" 6" 24" 48"0"
23-08
08-03
09-06
LEVEL 1
100' - 0"
TR
192A
06-01
09-01
09-18
26-05
26-11
26-12E
LEVEL 1
100' - 0"
TR
192A
CLEAR
1' - 0"
8'
6"
113-192.0
06-01
09-01
09-18
26-05
S
LEVEL 1
100' - 0"
TR
192A
06-01
09-18
09-18
GYPSUM BOARD COLUMN WRAP,
PAINT TO MATCH WALL
26-05
LEVEL 1
100' - 0"
TR
192A
26-04
06-01
09-01
09-18
26-05
FLOOR PLAN NOTES
1. SEE G SERIES SHEETS FOR BALANCE OF PLAN GENERAL NOTES.
2. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION. ALL INFORMATION
REGARDING EXISTING CONDITIONS IS BASED UPON OWNER-
SUPPLIED DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD
CONDITIONS.
3. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND
ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE
LOCATIONS.
4. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE
OF STUD, UNLESS OTHERWISE NOTED.
5. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND
REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.
6. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO
PROVIDE SUITABLE SUBSTRATE FOR FINISHES.
7. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS REQUIRING
ADA ACCESS CONTROL.
8. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND
BOTTOM, AND PENETRATIONS, AND INSTALL PUTTY PADS
AROUND ELECTRICAL BOXES WHERE PARTITION CONTAINS
ACOUSTICAL INSULATION.
9. ALL TELECOMMUNICATION ROOMS ARE TO HAVE EXPOSED
STRUCTURE UNLESS NOTED OTHERWISE, NO CEILINGS
SPECIFIED.
FLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
STRIP LIGHT FIXTURE, REF ELEC DRAWINGS
1. REFER TO ELECTRICAL SHEETS FOR FIXTURE TYPES,
SWITCHING, AND SPECIAL SYSTEMS.
2. REFER TO MECHANICAL SHEETS FOR DIFFUSER AND DUCTING
LAYOUTS
3. SEE SHEET 00-GI-006 FOR TYPICAL ACOUSTICAL PANEL CEILING
DETAILS
REFLECTED CEILING PLAN NOTES
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
WAITING
CASHIERS
TR
192A
PHARMACY
CORRIDOR
ACT-1
9' - 0"
GYP-1
10' - 0"
NORTHSCALE: 1/4" = 1'-0"
4' 3' 2' 1' 4' 8'0'
02-08
22-02
22-01
2x2 LIGHT FIXTURE
2x4 LIGHT FIXTURE
STRIP LIGHT FIXTURE
6" RECESSED CAN LIGHT FIXTURE
SUPPLY AIR DIFFUSER
RETURN AIR VENT
EXHAUST FAN
5/8" GYP. BOARD CEILING AFFIXED TO 3 5/8" MTL STUDS
2'x4' SUSPENDED ACOUSTIC CEILING TILE CEILING
GYP-1
ACT-2
REFLECTED CEILING PLAN LEGEND
2'x2' SUSPENDED ACOUSTIC CEILING TILE CEILINGACT-1
ELEC
ROOM
EC1F
PHARMACY
EXAM
189J
PHARMACY
WAITING
TOILET
189GA
09-25
09-06
23 SF
CLOSET
TC1A
09-29
09-25
09-06
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t M e a d e
S D
/2
B ld g r2
.r v t
-0
-2
:1
:1
113-AE-302
113-ENLARGED PLANS AND
ELEVATIONSGDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 113
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/2" = 1'-0"1
113 - 192 ENLARGED PLAN
1/2" = 1'-0"3
TR 192A EAST ELEVATION
1/2" = 1'-0"5
TR 192A NORTH ELEVATION
1/2" = 1'-0"8
TR 192A SOUTH ELEVATION
1/2" = 1'-0"11
TR 192A WEST ELEVATION
02-08 CAREFULLY REMOVE CEILING TILES AND OTHER CEILING MOUNTED
DEVICES, CAREFULLY STORE IN NON-TRAFFICKED AREA AND PREPARE FOR
REINSTALLATION AT COMPLETION OF WORK
06-01 INSTALL 3/4" AC GRADE OR BETTER FIRE RETARDANT PLYWOOD; PAINT
WITH TWO COATS OF SEMI-GLOSS BRIGHT WHITE FIRE RETARDANT PAINT;
MOUNT BOTTOM OF PLYWOOD 6" A.F.F., TOP OF PLYWOOD AT 8'-6" A.F.F.; DO
NOT PAINT OVER STAMPED PLYWOOD RATING
08-03 ADA DOOR CLEARANCES SHOWN DASHED
09-01 PAINT WALL ABOVE PLYWOOD WITH SEMI-GLOSS PAINT, COLOR TO MATCH
PLYWOOD PAINT.
09-02 PATCH ALL DAMAGED WORK ON EXISTING SURFACES ABOVE AND BELOW
CEILING TILES, PAINT ALL WALLS; PROVIDE NEW RESILIENT 6"H RESILIENT
WALL BASE
09-03 EXTEND EXISTING GYPSUM BOARD TO UNDERSIDE OF STRUCTURE WHERE
NOT INSTALLED, SEAL TO STRUCTURAL DECK
09-06 SEAL ALL WALL PENETRATIONS EXISTING AND NEW. PROVIDE APPROPRIATE
FIRE RATED UL HILTI DESIGNATION FOR PIPE AND/OR CONDUIT
PENETERATIONS; SEE TYPICAL PENETRATION DETAILS FOR RATED WALL
CONDITIONS.
09-07 INSTALL STATIC DISSIPATIVE RESILIENT FLOORING
09-11 INSTALL NEW WALL BASE TO MATCH TYPE, COLOR, AND PROFILE OF
EXISTING WALL BASE
09-18 6" HIGH COVED RUBBER WALL BASE, COLOR TO BE SELECTED FROM
MANUFACTURER'S STANDARD SELECTION
09-25 PATCH AND REPAIR ANY GYPSUM BOARD OPENINGS FOUND AT PERIMETER
OF WALL ENSURING NO VISIBLE EVIDENCE OF PATCH, SEAL PERIMETER OF
ROOM IN ITS ENTIRETY, PAINT;
09-29 INSTALL NEW FLOORING TO MATCH EXISTING SIMILAR USE ROOM
22-01 FIRE SUPPRESSION SPRINKLER HEAD SHOWN FOR REFERENCE ONLY; FIRE
SUPPRESSION CONTRACTOR TO VERIFY ACTUAL QUANTITIES REQUIRED,
INSTALL SYMMETRICALLY CENTER IN TILE.
22-02 UPRIGHT HEAD FIRE SUPPRESSION SPRINKLER HEAD SHOWN FOR
REFERENCE ONLY; FIRE SUPPRESSION CONTRACTOR TO VERIFY ACTUAL
QUANTITIES REQUIRED, COORDINATE INSTALLATION WITH MEPT DRAWINGS
23-08 NEW REFRIGERANT PIPE LINES ROUTING SHOWN FOR REFERENCE ONLY.
SEE MECHANICAL DRAWINGS FOR ACTUAL ROUTING; CONTRACTOR TO
REMOVE CEILING TILES ALONG ROUTE OUTSIDE OF TR'S AND REPLACE
WITHIN WORKING SHIFT. CONDUCT INFECTION PREVENTION MEASURES AS
SPECIFIED.
26-02 3' PERIMETER CLEARANCE AROUND SERVER RACK SHOWN DASHED
26-03 TELECOMM RACK, SEE TELECOMMUNICATION DRAWINGS
26-04 ELECTRICAL PANELS, SEE ELECTRICAL DRAWINGS
26-11 STROBE LIGHT, SEE ELECTRICAL DRAWINGS
26-12 ELECTRICAL OUTLETS MOUNTED ON PLYWOOD
KEYNOTES
1/4" = 1'-0"6
113 - 192 ENLARGED REFLECTED CEILING PLAN
1/4" = 1'-0"4
ECIF FLOOR PLAN
1/2" = 1'-0"2
113 - TC1A ENLARGED PLAN
O S
LEVEL 1
100' - 0"
TR
06-01
09-01
09-18
8'
6"
E26-12
26-05
LEVEL 1
100' - 0"
TR
06-01
09-18
09-01
26-05
LEVEL 1
100' - 0"
TR
09-01
09-18
23-05
06-01
LEVEL 1
100' - 0"
TR
8'
6"
06-01
26-04
09-18
09-01
113-169.0
26-05
E E26-12 26-12
26-11
S
09-09
EXTENT OF NEW GYPSUM
BOARD WALL INFILL
SHOWN DASHED
230 SF
TR
STORAGE
CLOSET
C-PAP
B-3
113-169.0
113-AE-303
26-04
26-02
26-03
06-01
06-01
06-01
09-02
09-02
09-07
NORTH
SCALE: 1/2" = 1'-0"
24" 18" 12" 6" 24" 48"0"
ALIGN NEW WALL
WITH EXISTING
03-01
23-08
09-09
FLOOR PLAN NOTES
1. SEE G SERIES SHEETS FOR BALANCE OF PLAN GENERAL NOTES.
2. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION. ALL INFORMATION
REGARDING EXISTING CONDITIONS IS BASED UPON OWNER-
SUPPLIED DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD
CONDITIONS.
3. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND
ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE
LOCATIONS.
4. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE
OF STUD, UNLESS OTHERWISE NOTED.
5. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND
REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.
6. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO
PROVIDE SUITABLE SUBSTRATE FOR FINISHES.
7. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS REQUIRING
ADA ACCESS CONTROL.
8. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND
BOTTOM, AND PENETRATIONS, AND INSTALL PUTTY PADS
AROUND ELECTRICAL BOXES WHERE PARTITION CONTAINS
ACOUSTICAL INSULATION.
9. ALL TELECOMMUNICATION ROOMS ARE TO HAVE EXPOSED
STRUCTURE UNLESS NOTED OTHERWISE, NO CEILINGS
SPECIFIED.
FLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
STRIP LIGHT FIXTURE, REF ELEC DRAWINGS
1. REFER TO ELECTRICAL SHEETS FOR FIXTURE TYPES,
SWITCHING, AND SPECIAL SYSTEMS.
2. REFER TO MECHANICAL SHEETS FOR DIFFUSER AND DUCTING
LAYOUTS
3. SEE SHEET 00-GI-006 FOR TYPICAL ACOUSTICAL PANEL CEILING
DETAILS
REFLECTED CEILING PLAN NOTES
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
TR
CORRIDOR
CLOSET
C-PAP
STORAGE
SCALE: 1/4" = 1'-0"
4' 3' 2' 1' 4' 8'0'
NORTH
22-02
EXP.
11' - 4"
23-08
26-05
2x2 LIGHT FIXTURE
2x4 LIGHT FIXTURE
STRIP LIGHT FIXTURE
6" RECESSED CAN LIGHT FIXTURE
SUPPLY AIR DIFFUSER
RETURN AIR VENT
EXHAUST FAN
5/8" GYP. BOARD CEILING AFFIXED TO 3 5/8" MTL STUDS
2'x4' SUSPENDED ACOUSTIC CEILING TILE CEILING
GYP-1
ACT-2
REFLECTED CEILING PLAN LEGEND
2'x2' SUSPENDED ACOUSTIC CEILING TILE CEILINGACT-1
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t M e a d e
S D
/2
B ld g r2
.r v t
-0
-2
:1
:1
113-AE-303
113-ENLARGED PLANS AND
ELEVATIONSGDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 113
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/2" = 1'-0"3
TR 169 NORTH ELEVATION
1/2" = 1'-0"6
TR 169 EAST ELEVATION
1/2" = 1'-0"2
TR 169 SOUTH ELEVATION
1/2" = 1'-0"5
TR 169 WEST ELEVATION
1/2" = 1'-0"1
113 -169 ENLARGED PLAN
03-01 NEW HOUSEKEEPING PAD, COORDINATE WITH MECHANICAL DRAWINGS FOR
SIZE AND CIVIL DRAWINGS FOR DETAILS
06-01 INSTALL 3/4" AC GRADE OR BETTER FIRE RETARDANT PLYWOOD; PAINT
WITH TWO COATS OF SEMI-GLOSS BRIGHT WHITE FIRE RETARDANT PAINT;
MOUNT BOTTOM OF PLYWOOD 6" A.F.F., TOP OF PLYWOOD AT 8'-6" A.F.F.; DO
NOT PAINT OVER STAMPED PLYWOOD RATING
09-01 PAINT WALL ABOVE PLYWOOD WITH SEMI-GLOSS PAINT, COLOR TO MATCH
PLYWOOD PAINT.
09-02 PATCH ALL DAMAGED WORK ON EXISTING SURFACES ABOVE AND BELOW
CEILING TILES, PAINT ALL WALLS; PROVIDE NEW RESILIENT 6"H RESILIENT
WALL BASE
09-07 INSTALL STATIC DISSIPATIVE RESILIENT FLOORING
09-09 APPLY JOINT COMPOUND AND FEATHER A MINIMUM OF 3' HORIZONTALLY AS
REQUIRED TO ACHIEVE A SMOOTH AND UNIFORM APPEARANCE
09-18 6" HIGH COVED RUBBER WALL BASE, COLOR TO BE SELECTED FROM
MANUFACTURER'S STANDARD SELECTION
22-02 UPRIGHT HEAD FIRE SUPPRESSION SPRINKLER HEAD SHOWN FOR
REFERENCE ONLY; FIRE SUPPRESSION CONTRACTOR TO VERIFY ACTUAL
QUANTITIES REQUIRED, COORDINATE INSTALLATION WITH MEPT DRAWINGS
23-05 MECHANICAL UNITS, SEE MECH DRAWINGS FOR SIZE AND SPECS
23-08 NEW REFRIGERANT PIPE LINES ROUTING SHOWN FOR REFERENCE ONLY.
SEE MECHANICAL DRAWINGS FOR ACTUAL ROUTING; CONTRACTOR TO
REMOVE CEILING TILES ALONG ROUTE OUTSIDE OF TR'S AND REPLACE
WITHIN WORKING SHIFT. CONDUCT INFECTION PREVENTION MEASURES AS
SPECIFIED.
26-02 3' PERIMETER CLEARANCE AROUND SERVER RACK SHOWN DASHED
26-03 TELECOMM RACK, SEE TELECOMMUNICATION DRAWINGS
26-04 ELECTRICAL PANELS, SEE ELECTRICAL DRAWINGS
26-05 CABLE TRAY, SEE TELECOMMUNICATION DRAWINGS
26-11 STROBE LIGHT, SEE ELECTRICAL DRAWINGS
26-12 ELECTRICAL OUTLETS MOUNTED ON PLYWOOD
KEYNOTES
1/4" = 1'-0"4
113 - 169 ENLARGED REFLECTED CEILING PLAN
BOILER ROOM
GENERATOR
STORAGE
C100
26-09
26-10
EXISTING GENERATOR EXHAUST
ENCLOSURE TO REMAIN
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
NORTH
EXP
EXPEXP
EXP
EXP
EXP
EXPOSED STRUCTURE FOR CABLE ROUTING
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
FLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
STRIP LIGHT FIXTURE, REF ELEC DRAWINGS
FLOOR PLAN NOTES
1. SEE G SERIES SHEETS FOR BALANCE OF FLOOR PLAN
GENERAL NOTES.
2. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION. ALL
INFORMATION REGARDING EXISTING CONDITIONS IS BASED
UPON OWNER-SUPPLIED DOCUMENTS AND MAY NOT
PRECISELY REFLECT FIELD CONDITIONS.
3. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY
AND ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES;
COORDINATE LOCATIONS.
4. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED
FACE OF STUD, UNLESS OTHERWISE NOTED.
5. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH
AND REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.
6. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED
TO PROVIDE SUITABLE SUBSTRATE FOR FINISHES.
7. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS
REQUIRING ADA ACCESS CONTROL.
8. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP
AND BOTTOM, AND PENETRATIONS, AND INSTALL PUTTY PADS
AROUND ELECTRICAL BOXES WHERE PARTITION CONTAINS
ACOUSTICAL INSULATION.
9. ALL TELECOMMUNICATION ROOMS ARE TO HAVE EXPOSED
STRUCTURE UNLESS NOTED OTHERWISE, NO CEILINGS
SPECIFIED.
ROOM
ROOM
BOILER ROOM
GENERATOR
103STORAGE
ROOM
ROOM
C100
13-01
EXISTING GENERATOR EXHAUST
ENCLOSURE TO REMAIN
CONSTRUCTION TRAFFIC
COORDINATE WITH C.O.R.
02-49
02-48
02-50
PROPOSED TELECOM CABINET LOCATION
F.E. (E)
01-01
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
NORTH
02-56
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t M e a d e
S D
/2
B ld g r2
.r v t
-0
-2
:1
:5
137-AE-200
137-FLOOR PLANS
GDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 137
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/8" = 1'-0"1
LEVEL 1 FLOOR PLAN
01-01 CLEAN UP AREA AROUND PROPOSED WALL MOUNTED CABINET LOCATION;
COORDINATE WITH C.O.R. FOR RELOCATION OR REMOVAL OF INSTALLATION
OBSTRUCTING ITEMS.
02-48 DEMO MECHANICAL WALL MOUNTED UNIT AND ASSOCIATED CONDUIT AND
SERVICES TO NEAREST J-BOX, CLEAN WALL AND PREPARE FOR
INSTALLTION OF WALL MOUNTED TELECOM CABINET
02-49 DEMO EXISTING LOUVER, PREPARE OPENING TO RECEIVE MASONRY WALL
INFIL
02-50 DEMO EXISTING CAGED LIGHT FIXTURES AND CONDUITS TO NEAREST J-BOX
02-56 CONTRACTOR TO ROUTE CONDUIT IN LEAST DESTRUCTIVE MANNER TO
LOCATIONS AS INDICATED IN TELECOMMUNICATION DRAWINGS,
CONTRACTOR TO BE RESPONSIBLE TO VISIT SITE AND UNDERSTAND
ROUTING AND MATERIAL TREATMENT; PATCH AND FINISH TO MATCH
EXISTING MATERIALS; TYPICAL AT ALL DATA DROP LOCATIONS
13-01 ICRA CLASS I, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND
WORKING HOURS RESTRICTIONS
26-09 30" CLEARANCE AT WALL MOUNTED SERVER RACK SHOWN DASHED
26-10 WALL MOUNTED TELECOM CABINET, SEE TELECOM DRAWINGS
KEYNOTES
1/8" = 1'-0"2
LEVEL 1 DEMOLITION FLOOR PLAN
UP
WAP
J
J
J
J
J
J
J J J
UP
J
SCALE: 1/16" = 1'-0"
16' 12' 8' 4' 16' 32'0'
NORTH
145-AE-301
TR
122B
EMS STORAGE
CLOSET
TC1A
CORRIDOR
122C
CORRIDOR
C101
145-AE-303
145-AE-302
HSK CLOSET
EXIT STAIRS
ST1C
CORRIDOR
C101C
CLOSET
HC1C
PBX
139B
STORAGE
139A
OIT
OFFICE
OFFICE
ELEC
PC1C I.T. WORK ROOM
03-01
MECH ROOM
CORRIDOR
C101B
EXIT STAIR
ST1B
STORAGE
ELEC ROOM
ROOM
111A
ROOM
ROOM
ROOM
ROOM
ROOM
108B
ROOM
RESTROOM
116A
PRIMARY CARE
OFFICE (x3)
EMS, OFFICE
EMS, OFFICE
115A
ROOM
BARBER SHOP
VEST
STAFF RESTROOM
ESCORT OFFICE
ROOM
ROOM
CORRIDOR
C101
LOADING AREA
HVAC OFFICE
122A
VENDING ROOM
CORRIDOR
C100
VENDING EQUIP
ROOM
MEDICAL RECORDS
OFFICE
OIT ASS. CHIEF
OFFICE
OIT, OFFICE
MECH ROOM
OIT CHIEF, OFFICE
OIT CHIEF, OFFICE
UPS
CORRIDOR
C101C
EMS EQUIP. ROOM
RESTROOM
MAIL ROOM
STORAGE
HC1B
EMS, OFFICE
115B
CLOSET
ESCORT OFFICE
120A
RESTROOM
PASSENGER ELEV.
EXIT STAIR
ST1A
STORAGE
EC1A
STORAGE
HC1A
1416 SF
DATA CENTER
ROOM
109A
ROOM
108A
ROOM
09-23
09-13
23-08
23-05
145-AE-301
03-01
26-13
ROOM ALLOCATION LEGEND
PROPOSED NEW CABINET / TR / MCR LOCATION
EXISTING TR WITH POWER AND FIBER
UPGRADES, SEE TELECOMM AND
ELECTRICAL DRAWINGS
ABANDONED ROOM
ROOM TO REMAIN, NO WORK
PROPOSED EXPANSION TO TR
REMODEL REQUIRED DUE TO EHRM IMPACT
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
FLOOR PLAN NOTES
1. SEE G SERIES SHEETS FOR BALANCE OF FLOOR PLAN
GENERAL NOTES.
2. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION. ALL
INFORMATION REGARDING EXISTING CONDITIONS IS BASED
UPON OWNER-SUPPLIED DOCUMENTS AND MAY NOT
PRECISELY REFLECT FIELD CONDITIONS.
3. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY
AND ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES;
COORDINATE LOCATIONS.
4. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED
FACE OF STUD, UNLESS OTHERWISE NOTED.
5. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP PATCH
AND REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.
6. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED
TO PROVIDE SUITABLE SUBSTRATE FOR FINISHES.
7. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS
REQUIRING ADA ACCESS CONTROL.
8. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP
AND BOTTOM, AND PENETRATIONS, AND INSTALL PUTTY PADS
AROUND ELECTRICAL BOXES WHERE PARTITION CONTAINS
ACOUSTICAL INSULATION.
9. ALL TELECOMMUNICATION ROOMS ARE TO HAVE EXPOSED
STRUCTURE UNLESS NOTED OTHERWISE, NO CEILINGS
SPECIFIED.
FLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
STRIP LIGHT FIXTURE, REF ELEC DRAWINGS
SCALE: 1/16" = 1'-0"
16' 12' 8' 4' 16' 32'0'
NORTH
TR
229A
ROOM
228E
CORRIDOR
CLOSET
TC2A
LIBRARY
228A
145-AE-304
CORRIDOR
C200
STAIR A
ST2A
ROOM
248A
ROOM
ELEVATOR
CLOSET
201A
NURSING
OFFICE
TOILET
MSA WORKROOM
OFFICE
TOILET
OFFICE
PHARMACY
EXAM
STORAGE
OFFICE
247C
OFFICE
247B
OFFICE
ROOM
HC2A
ROOM
EC2A
OFFICE
OFFICE
TOILET
207 TREATMENT
OFFICE
COMP & PEN V-TEL
TREATMENT
203/204
EDUCATION
STORAGE
228D
EMS STORAGE
PT STORAGE
ROOM
224A
RECEPTION
TREATMENT
222TREATMENT
STORAGE
EXIT STAIR
ST2B
STORAGE
OFFICE
217D
OFFICE
217C2
TREATMENT
217C1
CHARTING AREA
217C
PHYSICAL
THERAPY
ELEC
ROOM
HC2B
ROOM
PC2A
VEST
208TOILET
BREAK ROOM
TOILET
TREATMENT
OFFICE
VEST
TREATMENT
217A OFFICE
TREATMENT
217B
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
COMP & PEN V-TEL
OFFICE
236A
OFFICE
236B
TOILET
BREAK
EXAM
OFFICE
239D
OFFICE
239A
CONFERENCE
ROOM
239B
TOILET
CLOSET
PROSTHETICS
ELEC
ELEC
EC2B
WAITING ROOM
CHIRO SPACE
228B
LIBRARY
228C
BREAK
247A
STORAGE
209A
09-13
09-23
26-13
SCALE: 1/16" = 1'-0"
16' 12' 8' 4' 16' 32'0'
NORTH
TR
CLOSET
TC3A
OFFICE
CORRIDOR
C327A
CORRIDOR
C300
145-AE-305
CORRIDOR
ROOM
VEST
OFFICE
327A1
OFFICE
327A3
OFFICE
327A2
OFFICE
O…
This is the start of the file's text. The full file is on GovTribe.