Attachment 5 - Drawing 2 of 7.pdf
PDF 14 MB Posted
- Attached to
- Y1DA--EHRM Infrastructure Upgrade Construction Fort Meade VAMC Federal contract opportunity
- Solicitation number
- 36C77622B0055
About this file
This document provides details on a federal solicitation for construction services. The solicitation number is 36C77622B0055 and seeks offers for EHRM Infrastructure Upgrade Construction services at the Fort Meade VAMC. The Department of Veterans Affairs Technology Acquisition Center Austin is the contracting agency. The solicitation involves upgrading infrastructure at the Fort Meade Veterans Affairs Medical Center but provides no further specifics on requirements, response deadlines, or other contractual terms.
View the file
Other files for this federal contract opportunity
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
WAP
SCALE: 1/16" = 1'-0"
16' 12' 8' 4' 16' 32'0'
NORTH
145-AD-201
145-AD-201
145-AD-202
FOR DATA DROPS13-01
02-24
02-47
23-08
HSK CLOSET
EXIT STAIRS
ST1C
CORRIDOR
C101C
HC1C
TR
122B EMS STORAGE
CLOSET
TC1A
LOADING AREA
CORRIDOR
122C
CORRIDOR
C101
PBX
139B
STORAGE
139A
OIT
OFFICE
OFFICE
P C
1C
I.T. WORK ROOM
09-21
EC1B
P C
1B
ROOM
EXIT STAIR
ST1A
HVAC OFFICE
122A
ROOM
OIT, OFFICE
OIT CHIEF, OFFICE
UPS
EMS EQUIP. ROOM
HC1AEC1A
MAIL ROOM
RESTROOM
MEDICAL RECORDS
OFFICE
PASSENGER ELEV.
DATA CENTER
OIT ASS. CHIEF
OFFICE
125MECH ROOM
OIT CHIEF, OFFICE
ROOM
ROOM
ROOM
108B
ROOM
108A
ROOM
ROOM
ROOM
111A
STAFF RESTROOM
274ELEC ROOM
EXIT STAIR
ST1B
CLOSET
VEST
ESCORT OFFICE
ESCORT OFFICE
120A
EMS, OFFICE
115 RESTROOM
116A
HC1B
STORAGE
MECH ROOM
PRIMARY CARE
OFFICE (x3)
BARBER SHOP
EMS, OFFICE
115B
EMS, OFFICE
115A
ROOM
109A
ROOM
ROOM
ROOM
ROOM
RESTROOM
VENDING ROOM
VENDING EQUIP
ROOM
CORRIDOR
C100
CORRIDOR
C101A
CORRIDOR
C101B
145-AD-201
13-03
13-03
13-01 13-03
13-03
02-56
02-56
DEMOLITION LEGEND
INDICATES BUILT ITEM TO BE REMOVED
INDICATES LIGHT FIXTURE TO BE REMOVED
INDICATES EXTENT OF ICRA CLASS SCOPE
CABLE INSTALLATION ROUTE, FIELD VERIFY
CONDITIONS PRIOR TO COMMENCEMENT OF
WORK, SEE TELECOMM DRAWINGS FOR
EXTENT OF WORK
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
CONSTRUCTION TRAFFIC
THROUGH EXTERIOR DOOR
02-03
02-02
02-09
02-06
02-06
02-03
02-21
02-13
02-38
02-38
02-03
02-09
PATCH EXISTING CONCRETE SLAB,
REMOVE CONCRETE SEALANT,
REPAIR DAMAGES, AND PREPARE
TO RECEIVE NEW FLOORING
13-06
02-17
02-17
SCALE: 1/2" = 1'-0"
24" 18" 12" 6" 24" 48"0"
NORTH
CUT AND REMOVE EXISTING TREE AND STUMP
EXTENT OF NEW SCREEN WALL, SEE
ENLARGED FLOOR PLAN
EXISTING AREAWAY TO REMAIN
CONTRACTOR TO REPLACE AND REPAIR
EXISTING IRRIGATION SYSTEM IF
DAMAGED BY CONSTRUCTION ACTIVITIES
02-53
02-54
02-53 02-53
02-5302-53
TR
122B
LOADING AREA
CLOSET
TC1A
02-09
02-0602-06
02-11
02-12
02-10
02-16
02-27
EMS STORAGE
13-06
CONSTRUCTION TRAFFIC
THROUGH EXTERIOR DOOR
02-47 02-25
23-08
ROOM ALLOCATION LEGEND
PROPOSED NEW CABINET / TR / MCR LOCATION
EXISTING TR WITH POWER AND FIBER
UPGRADES, SEE TELECOMM AND
ELECTRICAL DRAWINGS
ABANDONED ROOM
ROOM TO REMAIN, NO WORK
PROPOSED EXPANSION TO TR
REMODEL REQUIRED DUE TO EHRM IMPACT
UPS
CORRIDOR
C101C
EMS EQUIP. ROOM
OIT CHIEF, OFFICE
02-04
02-30
02-11
02-03
02-55
DEMOLITION GENERAL NOTES
1. SEE G SERIES SHEETS FOR ALL DEMOLITION NOTES & HAZARDOUS
MATERIAL NOTES
2. IN HOSPITAL OCCUPANCY, CONTRACTOR ARE TO USE A
CONSTRUCTION CONTAINMENT CUBE WITH HEPA VACUUM TO MAINTAIN
NEGATIVE PRESSURE AS A MEANS TO ACCESS AREAS ABOVE CEILING
TILES. THIS INCLUDES ALL PATIENT CORRIDORS AND ALL ACUTE CARE
PATIENT AREAS. THIS IS IN CONJUNCTION WITH THE HOSPITALS
INFECTION PREVENTION MEASURES AND ICRA PROTOCOLS.
3. MAINTAIN FIRE SUPPRESSION SYSTEM OPERATIONAL DURING
CONSTRUCTION WORK. FIRE SUPPRESSION CONTRACTOR TO REMOVE
DOWNWARD HEADS AND TURN UPWARS, PROVIDE NEW FIRE
SUPPRESSION HEAD IN TELECOMMUNICATION ROOMS (TR). WORK TO
BE CONDUCTED WITHIN ONE WORKING SHIFT. SEE ADDITIONAL
PROJECT NOTES ON COVER SHEET.
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t M e a d e
S D
/2
B ld g r2
.r v t
-0
-2
:2
:5
145-AD-201
145-DEMOLITION FLOOR PLAN
GDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 145
Project Director
JRPTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/16" = 1'-0"1
LEVEL 1 FLOOR PLAN
1/4" = 1'-0"4
ENLARGED MCR DEMOLITION PLAN
02-02 CAREFULLY REMOVE EXISTING DOOR, FRAME, AND HARDWARE, STORE IN
NON-TRAFFICKED AREA AND PREPARE FOR REINSTALLATION
02-03 CAREFULLY REMOVE EXISTING DOOR, FRAME AND HARDWARE, RETURN TO
OWNER
02-04 DEMO CARPET, BASE, AND ADHESIVES; PREPARE FLOOR FOR NEW STATIC
DISSIPATIVE RESILIENT FLOORING AND BASE
02-06 DEMO EXISTING WALL IN ITS ENTIRETY INCLUDING ANY WALL MOUNTED
DEVICES, TERMINATE CONDUITS AT NEAREST J-BOX, PREP FLOOR TO RECEIVE
NEW FINISH
02-09 DEMO WALL AS REQUIRED TO RECEIVE NEW DOOR AND FRAME
02-10 DEMO EXISTING LAUNDRY CHUTE ACCESS DOOR, DEMO METAL CHUTE, AND
INSTALL 2-HOUR FLOOR CLOSURE ABOVE
02-11 EXTENT OF DEMOLITION WORK SHOWN DASHED
02-12 DEMO/RELOCATE EXISTING ELECTRICAL PANELS, SEE ELECTRICAL AND
TELECOM DRAWINGS
02-13 DEMO EXISTING CONCRETE RAMP AND RAIL IN ITS ENTIRETY
02-16 DEMO PLUMBING HOOKUPS AND TERMINATE BEHIND WALL AS PER PLUMBING
DRAWINGS
02-17 PATCH/REPAIR ALL WALL DAMAGE TO UNDERSIDE OF STRUCTURAL DECK AND
PREPARE FOR NEW FINISHES IF SPECIFIED, TYP.; EXTEND WALL TO DECK IF
NOT IN PLACE. PATCH FIRE RATED WALLS WITH APPROPRIATE FIRE RATED
SYSTEMS TO MAINTAIN EXISTING WALL INTEGRITY
02-21 DEMO EXISTING PLUMBING FIXTURES, WALL TILE IF ANY, AND PLUMBING
ACCESSORIES. CAP AND TERMINATE PER PLUMBING DRAWINGS.
02-24 CORE DRILL THROUGH MASONRY WALL AS REQUIRED, PROVIDE OPENING 1/2"
LARGER THAN CONDUIT SIZE, SEE MECHANICAL AND/OR TELECOM DRAWINGS
FOR CONDUIT SIZE AND QUANTITES. PATCH AND SEAL ALL NEW
PENETRATIONS. APPLY APPROPRIATE HILTI FIRE RATED SEAL FOR TYPE OF
PENETRATION AT RATED WALL CONDITION.
02-25 CORE DRILL THROUGH FLOOR NEW PIPE OR CONDUIT INSTALLATION; APPLY
APPROPRIATE HILTI FIRE RATED SEAL FOR TYPE OF PENETRATION; SEE MEP
OR TELECOM DRAWINGS FOR COORDINATION
02-27 DEMO EXISTING TILE FLOOR, APPLY SELF LEVELING COMPOUND AND PREPARE
TO RECEIVE NEW FLOORING.
02-30 DEMO EXISTING CEILING TILE, LIGHT FIXTURES AND ANY CEILING MOUNTED
DEVICES; REMOVE EXISTING SPRINKLER HEADS AND TURN UP DISCHARGE
PIPE, PROVIDE NEW FIRE SUPPRESSION HEADS AT EXPOSED CONDITIONS
02-38 DEMO EXISTING STEEL RAILING
02-47 CORE DRILL THROUGH FIRE RATED WALL FOR NEW CONDUIT/CABLE
PENETRATION, SEAL WITH APPROPRIATE HILTI SYSTEM AT COMPLETION OF
WORK, LABEL ACCORDINGLY
02-53 DEMO EXISTING WINDOW, PREPARE FOR NEW GLASS BLOCK INSTALLATION
02-54 HATCHED AREA SHOWS EXTENT OF PROPOSED CONCRETE RAMP AND STAIRS;
SAWCUT EXISTING SLAB, EXCAVATE AS REQUIRED AND PREPARE TO RECEIVE
NEW FOUNDATIONS, SEE STRUCTURAL DRAWINGS
02-55 DEMO EXISTING MECHANICAL WINDOW UNIT, REPLACE W/ INSULATED PANEL.
02-56 CONTRACTOR TO ROUTE CONDUIT IN LEAST DESTRUCTIVE MANNER TO
LOCATIONS AS INDICATED IN TELECOMMUNICATION DRAWINGS, CONTRACTOR
TO BE RESPONSIBLE TO VISIT SITE AND UNDERSTAND ROUTING AND MATERIAL
TREATMENT; PATCH AND FINISH TO MATCH EXISTING MATERIALS; TYPICAL AT
ALL DATA DROP LOCATIONS
09-21 REMOVE AND RE-INSTALL CEILING TILES AND OTHER CEILING MOUNTED
DEVICES AS NEEDED FOR INSTALLATION OF CABLES AND CONDUITS ABOVE
CEILING AS PER TELECOM DRAWINGS, REPLACE ALL DAMANGED TILES TO
MATCH EXISTING AND REINSTALL ALL DEVICES AS NEEDED. DO NOT LEAVE
CEILING TILES UNINSTALLED AND UNATTENDED PAST DURATION OF WORKING
SHIFT. CONTINUOUSLY REINSTALL TILES TO PROVIDE SEALED SMOKE
ASSEMBLY.
13-01 ICRA CLASS I, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND WORKING
HOURS RESTRICTIONS
13-03 ICRA CLASS III, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND
WORKING HOURS RESTRICTIONS
13-06 INFECTION PREVENTION, FIRE RATED, 6MM PLASTIC BARRIER SEALED TOP,
BOTTOM, AND SIDES. PROVIDE VESTIBULE AREA FOR GOWNING AND
UNGOWNING AND NEGATIVE PRESSURE WITHIN CONSTRUCTION AREA IN ICRA
CLASS IV. SEE SPECS FOR OTHER ICRA CONSTRUCTION REQUIREMENTS
23-08 NEW REFRIGERANT PIPE LINES ROUTING SHOWN FOR REFERENCE ONLY. SEE
MECHANICAL DRAWINGS FOR ACTUAL ROUTING; CONTRACTOR TO REMOVE
CEILING TILES ALONG ROUTE OUTSIDE OF TR'S AND REPLACE WITHIN
WORKING SHIFT. CONDUCT INFECTION PREVENTION MEASURES AS SPECIFIED.
1/4" = 1'-0"2
LEVEL 1 ROOM 122B DEMOLITION FLOOR PLAN
1/4" = 1'-0"3
NEW UPS DEMOLITION FLOOR PLAN
KEY NOTES
Revisions: Date:
? 12" = 1'-0"
DEMOLITION GENERAL NOTES
WAP
SCALE: 1/16" = 1'-0"
16' 12' 8' 4' 16' 32'0'
NORTH
DEMOLTION AREA SCOPE OF WORK145-AD-202
TR
229A
ROOM
228E
CORRIDOR
CLOSET
TC2A
LIBRARY
228A
CORRIDOR
C200
13-03
13-02 FOR DATA DROPS
09-21
STAIR A
ST2A
ROOM
248A
ROOM
ELEVATOR
227A ROOM
ELEVATOR
OFFICE
OFFICE
OFFICE
242CLOSET
201A
NURSING
OFFICE
TOILET
MSA WORKROOM
OFFICE
TOILET
OFFICE
PHARMACY
EXAM
250 STORAGE
OFFICE
247C
OFFICE
247B
OFFICE
HC2AEC2A
OFFICE
OFFICE
TOILET
TREATMENT
OFFICE
COMP & PEN V-TEL
TREATMENT
203/204
EDUCATION
STORAGE
228D
EMS STORAGE
ROOM
PT STORAGE
ROOM
224A
RECEPTION
TREATMENT
TREATMENT
STORAGE
EXIT STAIR
ST2B
ELEC
EC2B
STORAGE
OFFICE
217D
OFFICE
217C2
TREATMENT
217C1
CHARTING AREA
217C
PHYSICAL
THERAPY
ELEC
HC2B
P C
2A
VEST
TOILET
BREAK ROOM
P C
2B
TOILET
TREATMENT
OFFICE
VEST
TREATMENT
217A
OFFICE
TREATMENT
217B
OFFICE
OFFICE
COMP & PEN V-TEL
OFFICE
236A
OFFICE
236B
TOILET
BREAK
EXAM
OFFICE
239D
OFFICE
239A
CONFERENCE
ROOM
239B
TOILET
CLOSET
PROSTHETICS
ELEC
WAITING ROOM
CHIRO SPACE
228B
LIBRARY
228C
BREAK
247A
STORAGE
209A
02-56
02-57
SCALE: 1/16" = 1'-0"
16' 12' 8' 4' 16' 32'0'
NORTH
DEMOLTION AREA SCOPE OF WORK
145-AD-202
FOR DATA DROPS13-02
09-21
TR
CLOSET
TC3A
OFFICE
CORRIDOR
C327A
CORRIDOR
C300
CORRIDOR
ROOM
VEST
OFFICE
327A1
OFFICE
327A3
OFFICE
327A2
OFFICE
OFFICE
EC3A
OFFICE
ROOM
328B
ELEVATOR
ROOM
328A
OFFICE
OFFICE
STOR
301A
STOR
333A
OFFICE
OFFICE
303/304
ROOM
DENTAL LAB
314 DENTAL
313G
DENTAL
313F
P C
3B
RECEPTION
313B
CLOSET
313E
TOILET
BREAK ROOM
STOR
TOILET
315A
STOR
EXAM
317 STOR
313C
STOR
313D
STAIR B
ST3BBREAK
315 TOILET
ROOM
322A
ROOM
322B
PROCEDURE
STOR
322C
CORRIDOR
C300A1
OFFICE
CORRIDOR
C313
CONFERENCE
ROOM
341B
OFFICE
TOILET
OFFICE
OFFICE
STOR
341C
EC3C
STOR
OFFICE
OFFICE
OFFICE
ROOM
P C
3C
LOCKER ROOM
BREAK ROOM
SUPPLY
OFFICE
OFFICE
OFFICE
SWING SPACE
341D
OFFICE
HC3A
STAIR A
ST3A
EMPLOYEE
FITNESS CENTER
LOCKER ROOM
HC3C
ROOM
STAIR C
ST3C
OFFICE
341ATOILET
STOR
OFFICE
OFFICE
EXAM
309A
EXAM
309B
EXAM
309C
EXAM
309D
PROCEDURE
310A
TOILET
EC3B
CORRIDOR
C300A
ROOM
305B
ROOM
310B
OFFICE
CORRIDOR
C300B
EXAM
ROOM
ROOM
ROOM
ROOM
EYE CLINIC
ROOM
305A
WAITING ROOM
313A
WAITING
13-03
02-56
02-57
DEMOLITION LEGEND
INDICATES BUILT ITEM TO BE REMOVED
INDICATES LIGHT FIXTURE TO BE REMOVED
INDICATES EXTENT OF ICRA CLASS SCOPE
CABLE INSTALLATION ROUTE, FIELD VERIFY
CONDITIONS PRIOR TO COMMENCEMENT OF
WORK, SEE TELECOMM DRAWINGS FOR
EXTENT OF WORK
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
CORRIDOR
C200
ROOM
228E
CLOSET
TC2A
CORRIDOR
02-09
02-17
02-04
02-11
13-06
13-06
02-25
TR
CORRIDOR
C327A
OFFICE
CLOSET
TC3A
CORRIDOR
C300
02-06
02-03
02-11
13-06
13-06
13-06
02-25
PBX
139B
STORAGE
139A
OFFICE
OIT
OIT
OIT
CORRIDOR
C101C
OIT
OIT
02-22
02-03
02-22
02-06
02-03
02-03
02-03
02-03
02-04
02-06
02-06
02-03
02-06
02-19
02-19
02-37
02-27
13-07
13-12
DEMO EXISTING RAMP
AND ALUMINUM RAILING
DEMO WALL BELOW WINDOW TO FLOOR,
ADD SELF LEVELING COMPOUND AS
REQUIRED, PREPARE TO RECEIVE
FINISHES AT PERIMETER OF OPENING
PREPARE FOR
WALL INFILL
CONSTRUCTION TRAFFIC
NORTH
SCALE: 1/4" = 1'-0"
4' 3' 2' 1' 4' 8'0'
02-19
02-03
02-03
02-06
02-06
02-06
02-04 02-04
DEMO ELECTRICAL PANELS,
SEE ELECTRICAL DRAWINGS
FOR EXTENT
(E) ANALOG TELEPHONE RACKS TO REMAIN
(E
R A
IS
E
D F
LO
O
R T
O R
E M
A
IN
8'
/2
DEMO FLOOR TO PANEL JOINT
ROOM ALLOCATION LEGEND
PROPOSED NEW CABINET / TR / MCR LOCATION
EXISTING TR WITH POWER AND FIBER
UPGRADES, SEE TELECOMM AND
ELECTRICAL DRAWINGS
ABANDONED ROOM
ROOM TO REMAIN, NO WORK
PROPOSED EXPANSION TO TR
REMODEL REQUIRED DUE TO EHRM IMPACT
DEMOLITION GENERAL NOTES
1. SEE G SERIES SHEETS FOR ALL DEMOLITION NOTES & HAZARDOUS
MATERIAL NOTES
2. IN HOSPITAL OCCUPANCY, CONTRACTOR ARE TO USE A
CONSTRUCTION CONTAINMENT CUBE WITH HEPA VACUUM TO MAINTAIN
NEGATIVE PRESSURE AS A MEANS TO ACCESS AREAS ABOVE CEILING
TILES. THIS INCLUDES ALL PATIENT CORRIDORS AND ALL ACUTE CARE
PATIENT AREAS. THIS IS IN CONJUNCTION WITH THE HOSPITALS
INFECTION PREVENTION MEASURES AND ICRA PROTOCOLS.
3. MAINTAIN FIRE SUPPRESSION SYSTEM OPERATIONAL DURING
CONSTRUCTION WORK. FIRE SUPPRESSION CONTRACTOR TO REMOVE
DOWNWARD HEADS AND TURN UPWARS, PROVIDE NEW FIRE
SUPPRESSION HEAD IN TELECOMMUNICATION ROOMS (TR). WORK TO
BE CONDUCTED WITHIN ONE WORKING SHIFT. SEE ADDITIONAL
PROJECT NOTES ON COVER SHEET.
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t M e a d e
S D
/2
B ld g r2
.r v t
-0
-2
:2
:0
145-AD-202
145-DEMOLITION 2ND AND 3RD
LEVEL PLANSGDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 145
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/16" = 1'-0"2
LEVEL 2 FLOOR PLAN
1/16" = 1'-0"1
LEVEL 3 FLOOR PLAN
02-03 CAREFULLY REMOVE EXISTING DOOR, FRAME AND HARDWARE, RETURN TO OWNER
02-04 DEMO CARPET, BASE, AND ADHESIVES; PREPARE FLOOR FOR NEW STATIC
DISSIPATIVE RESILIENT FLOORING AND BASE
02-06 DEMO EXISTING WALL IN ITS ENTIRETY INCLUDING ANY WALL MOUNTED DEVICES,
TERMINATE CONDUITS AT NEAREST J-BOX, PREP FLOOR TO RECEIVE NEW FINISH
02-09 DEMO WALL AS REQUIRED TO RECEIVE NEW DOOR AND FRAME
02-11 EXTENT OF DEMOLITION WORK SHOWN DASHED
02-17 PATCH/REPAIR ALL WALL DAMAGE TO UNDERSIDE OF STRUCTURAL DECK AND
PREPARE FOR NEW FINISHES IF SPECIFIED, TYP.; EXTEND WALL TO DECK IF NOT IN
PLACE. PATCH FIRE RATED WALLS WITH APPROPRIATE FIRE RATED SYSTEMS TO
MAINTAIN EXISTING WALL INTEGRITY
02-19 DEMO EXISTING FLOOR AND WALL MOUNTED PLUMBING FIXTURES IN THEIR
ENTIRETY, TILE WALLS, AND PLUMBING. CAP AND TERMINATE AS PER PLUMBING
DRAWINGS LEVEL FLOOR AS REQUIRED AND PREPARE TO RECEIVE NEW FINISHES.
02-22 CAREFULLY REMOVE RAISED FLOOR TILES FOR REMOVAL OF CABLES PER TELECOM
DRAWINGS, CAREFULLY STORE IN NON-TRAFFICKED AREA AND PREPARE FOR
REINSTALLATION AT COMPLETION OF WORK. CONTRACTOR TO TAKE INVENTORY AND
REMOVE ALL CUT TILES; REPLACE CUT AND DAMAGED TILES; SEE SPECS AND
TELECOM DRAWINGS FOR TILE REPLACEMENTS
02-25 CORE DRILL THROUGH FLOOR NEW PIPE OR CONDUIT INSTALLATION; APPLY
APPROPRIATE HILTI FIRE RATED SEAL FOR TYPE OF PENETRATION; SEE MEP OR
TELECOM DRAWINGS FOR COORDINATION
02-27 DEMO EXISTING TILE FLOOR, APPLY SELF LEVELING COMPOUND AND PREPARE TO
RECEIVE NEW FLOORING.
02-37 DEMO EXISTING WINDOW AND PERIMETER AS REQUIRED FOR INSTALLATION OF NEW
DOOR OR DOOR OPENING
02-56 CONTRACTOR TO ROUTE CONDUIT IN LEAST DESTRUCTIVE MANNER TO LOCATIONS
AS INDICATED IN TELECOMMUNICATION DRAWINGS, CONTRACTOR TO BE
RESPONSIBLE TO VISIT SITE AND UNDERSTAND ROUTING AND MATERIAL TREATMENT;
PATCH AND FINISH TO MATCH EXISTING MATERIALS; TYPICAL AT ALL DATA DROP
LOCATIONS
02-57 REMOVE CEILING TILES AS SPECIFIED IN ICRA GUIDELINES PER RISK CLASSIFICATION
NOTED FOR CABLING INSTALLATION. COORDINATE EXTENT OF WORK WITH
TELECOMMUNICATION DRAWINGS
09-21 REMOVE AND RE-INSTALL CEILING TILES AND OTHER CEILING MOUNTED DEVICES AS
NEEDED FOR INSTALLATION OF CABLES AND CONDUITS ABOVE CEILING AS PER
TELECOM DRAWINGS, REPLACE ALL DAMANGED TILES TO MATCH EXISTING AND
REINSTALL ALL DEVICES AS NEEDED. DO NOT LEAVE CEILING TILES UNINSTALLED AND
UNATTENDED PAST DURATION OF WORKING SHIFT. CONTINUOUSLY REINSTALL TILES
TO PROVIDE SEALED SMOKE ASSEMBLY.
13-02 ICRA CLASS II, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND WORKING
HOURS RESTRICTIONS
13-03 ICRA CLASS III, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND WORKING
HOURS RESTRICTIONS
13-06 INFECTION PREVENTION, FIRE RATED, 6MM PLASTIC BARRIER SEALED TOP, BOTTOM,
AND SIDES. PROVIDE VESTIBULE AREA FOR GOWNING AND UNGOWNING AND
NEGATIVE PRESSURE WITHIN CONSTRUCTION AREA IN ICRA CLASS IV. SEE SPECS
FOR OTHER ICRA CONSTRUCTION REQUIREMENTS
13-07 SEAL PERIMETER OF DOOR TO MAINTAIN NEGATIVE PRESSURE WITHIN
CONSTRUCTION AREA; PROTECT FINISH DURING CONSTRUCTION
13-12 CONSTRUCT A TEMPORARY 1-HOUR FIRE RESISTIVE BARRIER TO UNDERSIDE OF
STRUCTURE; REMOVE CEILING TILE TO ALLOW WALL EXTENSION, REINSTALL AFTER
WORK IS COMPLETED; COORDINATE WITH C.O.R. EXACT LOCATION OF WALL
INSTALLATION.
1/4" = 1'-0"5
LEVEL 2 DEMOLITION ENLARGED FLOOR PLAN
1/4" = 1'-0"4
LEVEL 3 DEMOLITION ENLARGED FLOOR PLAN
1/4" = 1'-0"3
LEVEL 1 DEMOLITION OIT DEPARTMENT FLOOR PLAN
KEY NOTES
Revisions: Date:
UPUP
1 3 4 5 5 5 10
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
NORTH
146-AD-201
13-02
TR
LOCKERS
ELEC
CHEMICAL STORAGE
ROOM
HC1A
CORRIDOR
C103
TR
LOCKERS
ELEC
CHEMICAL STORAGE
ROOM
HC1A
CORRIDOR
C103
OFFICE
107A
POT/PAN WASHER
AREA
106C
STORAGE
111A
CLOSET
107B
STORAGE
STORAGE
114A1
THAWBOX
114A
STORAGE
114B
FOOD
PREPERATION
CORRIDOR
C104
BREAKROOM
112RESTROOM
109A
ADMIN AREA
HC1G
STORAGE
106D2
REFRIG
106D1
REFRIG
106E
STORAGE
CANTEEN DINING
ROOM
CANTEEN DISH
ROOM
CANTEEN
COOLER
115A
FREEZER
115B
FOOD
PREPERATION
CANTEEN
FREEZER
115A1
MAT. WASH
104A
STORAGE
116B
STAIR
NON-FOOD
STORAGE
WOMEN'S LOCKER
ROOM
RESTROOM
119A
DRUG CACHE
116A
REEFER/PUMP
ROOM
PAPER
STORAGE
116C
DRY FOOD
STORAGE
VESTIBULE
120A1
STORAGE
COOK'S WALK-IN
COOLER
106B
OFFICE
106A
FREEZER
114C
STORAGE
123B
CANTEEN
STORAGE
WOMEN'S
RESTROOM
MEN'S
RESTROOM
C101
CANTEEN RETAIL
STORE
OFFICE
123A1
OFFICE
123A
CANTEEN KITCHEN
LOADING DOCK
LD1
STORAGE
ROOM
106D
CORRIDOR
C100
CORRIDOR
C102
PATIENT DINING
ROOM
105A
SERVER LINE
C105
NFS DISH ROOM
KITCHEN
EQUIPMENT ROOM
CANTEEN
STORAGE
120A
CORRIDOR
C101
CORRIDOR
CC2-146
LOADING
DOCK
LD2
02-08
02-24
02-08
09-21
13-03
CABLING
02-56
PLASTER CEILINGS THROUGHOUT
DEMOLITION LEGEND
INDICATES BUILT ITEM TO BE REMOVED
INDICATES LIGHT FIXTURE TO BE REMOVED
INDICATES EXTENT OF ICRA CLASS SCOPE
CABLE INSTALLATION ROUTE, FIELD VERIFY
CONDITIONS PRIOR TO COMMENCEMENT OF
WORK, SEE TELECOMM DRAWINGS FOR
EXTENT OF WORK
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
PROPOSED NEW TR LOCATION
EXISTING TR TO BE UPDATED
ROOM ALLOCATION LEGEND
ABANDONED ROOM
ROOM TO REMAIN, NO WORK
PROPOSED EXPANSION TO TR
REMODEL REQUIRED DUE TO EHRM IMPACT
TR
LOCKERS
ELEC
CHEMICAL STORAGE
CORRIDOR
C103
OFFICE
107A
02-17
02-03
02-20
02-30
13-06
13-06
02-28
02-17
NORTH
SCALE: 1/4" = 1'-0"
4' 3' 2' 1' 4' 8'0'
TR
LOCKERS
ELEC
CHEMICAL STORAGE
ROOM
HC1A
CORRIDOR
C103
OFFICE
107A
02-24
23-08
DEMOLITION GENERAL NOTES
1. SEE G SERIES SHEETS FOR ALL DEMOLITION NOTES & HAZARDOUS
MATERIAL NOTES
2. IN HOSPITAL OCCUPANCY, CONTRACTOR ARE TO USE A
CONSTRUCTION CONTAINMENT CUBE WITH HEPA VACUUM TO MAINTAIN
NEGATIVE PRESSURE AS A MEANS TO ACCESS AREAS ABOVE CEILING
TILES. THIS INCLUDES ALL PATIENT CORRIDORS AND ALL ACUTE CARE
PATIENT AREAS. THIS IS IN CONJUNCTION WITH THE HOSPITALS
INFECTION PREVENTION MEASURES AND ICRA PROTOCOLS.
3. MAINTAIN FIRE SUPPRESSION SYSTEM OPERATIONAL DURING
CONSTRUCTION WORK. FIRE SUPPRESSION CONTRACTOR TO REMOVE
DOWNWARD HEADS AND TURN UPWARS, PROVIDE NEW FIRE
SUPPRESSION HEAD IN TELECOMMUNICATION ROOMS (TR). WORK TO
BE CONDUCTED WITHIN ONE WORKING SHIFT. SEE ADDITIONAL
PROJECT NOTES ON COVER SHEET.
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t M e a d e
S D
/2
B ld g r2
.r v t
-0
-2
:2
:1
146-AD-201
146-DEMOLITION FLOOR PLAN
GDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 146
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/8" = 1'-0"1
146 - LEVEL 1 DEMOLITION PLAN
02-03 CAREFULLY REMOVE EXISTING DOOR, FRAME AND HARDWARE, RETURN
TO OWNER
02-08 CAREFULLY REMOVE CEILING TILES AND OTHER CEILING MOUNTED
DEVICES ALONG ABOVE CEILING WORK ROUTE, CAREFULLY STORE IN
NON-TRAFFICKED AREA AND PREPARE FOR REINSTALLATION AT
COMPLETION OF WORK
02-17 PATCH/REPAIR ALL WALL DAMAGE TO UNDERSIDE OF STRUCTURAL DECK
AND PREPARE FOR NEW FINISHES IF SPECIFIED, TYP.; EXTEND WALL TO
DECK IF NOT IN PLACE. PATCH FIRE RATED WALLS WITH APPROPRIATE
FIRE RATED SYSTEMS TO MAINTAIN EXISTING WALL INTEGRITY
02-20 DEMO FLOOR & FLOOR BASE, PATCH WALLS, PREPARE FOR NEW FINISHES
02-24 CORE DRILL THROUGH MASONRY WALL AS REQUIRED, PROVIDE OPENING
1/2" LARGER THAN CONDUIT SIZE, SEE MECHANICAL AND/OR TELECOM
DRAWINGS FOR CONDUIT SIZE AND QUANTITES. PATCH AND SEAL ALL NEW
PENETRATIONS. APPLY APPROPRIATE HILTI FIRE RATED SEAL FOR TYPE
OF PENETRATION AT RATED WALL CONDITION.
02-28 SEE ELECTRICAL DRAWINGS FOR DEMO OF ELECTRICAL PANEL; DEMO
THROUGH THE FLOOR CONDUIT, PATCH FLOOR AND PREPARE FOR NEW
FINISHES
02-30 DEMO EXISTING CEILING TILE, LIGHT FIXTURES AND ANY CEILING
MOUNTED DEVICES; REMOVE EXISTING SPRINKLER HEADS AND TURN UP
DISCHARGE PIPE, PROVIDE NEW FIRE SUPPRESSION HEADS AT EXPOSED
CONDITIONS
02-56 CONTRACTOR TO ROUTE CONDUIT IN LEAST DESTRUCTIVE MANNER TO
LOCATIONS AS INDICATED IN TELECOMMUNICATION DRAWINGS,
CONTRACTOR TO BE RESPONSIBLE TO VISIT SITE AND UNDERSTAND
ROUTING AND MATERIAL TREATMENT; PATCH AND FINISH TO MATCH
EXISTING MATERIALS; TYPICAL AT ALL DATA DROP LOCATIONS
09-21 REMOVE AND RE-INSTALL CEILING TILES AND OTHER CEILING MOUNTED
DEVICES AS NEEDED FOR INSTALLATION OF CABLES AND CONDUITS
ABOVE CEILING AS PER TELECOM DRAWINGS, REPLACE ALL DAMANGED
TILES TO MATCH EXISTING AND REINSTALL ALL DEVICES AS NEEDED. DO
NOT LEAVE CEILING TILES UNINSTALLED AND UNATTENDED PAST
DURATION OF WORKING SHIFT. CONTINUOUSLY REINSTALL TILES TO
PROVIDE SEALED SMOKE ASSEMBLY.
13-02 ICRA CLASS II, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND
WORKING HOURS RESTRICTIONS
13-03 ICRA CLASS III, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND
WORKING HOURS RESTRICTIONS
13-06 INFECTION PREVENTION, FIRE RATED, 6MM PLASTIC BARRIER SEALED TOP,
BOTTOM, AND SIDES. PROVIDE VESTIBULE AREA FOR GOWNING AND
UNGOWNING AND NEGATIVE PRESSURE WITHIN CONSTRUCTION AREA IN
ICRA CLASS IV. SEE SPECS FOR OTHER ICRA CONSTRUCTION
REQUIREMENTS
23-08 NEW REFRIGERANT PIPE LINES ROUTING SHOWN FOR REFERENCE ONLY.
SEE MECHANICAL DRAWINGS FOR ACTUAL ROUTING; CONTRACTOR TO
REMOVE CEILING TILES ALONG ROUTE OUTSIDE OF TR'S AND REPLACE
WITHIN WORKING SHIFT. CONDUCT INFECTION PREVENTION MEASURES AS
SPECIFIED.
1/4" = 1'-0"10
LEVEL 1 ENLARGED DEMOLITION PLAN
FC
P
SCALE: 1/16" = 1'-0"
16' 12' 8' 4' 16' 32'0'
NORTH
148-AD-301
148-AD-301
148-AD-301
148-AD-301
TR
C106A
OFFICE
C106B
ORGANIZATIONAL
IMPROVEMENT
OFFICE
C106
STORAGE
C103
CORRIDOR
CC104
CORRIDOR
CC100
CORRIDOR
CC101
TR
A114A
SOIL HOLD
ATC2
REC STORAGE
A115
CORRIDOR
AC101
CORRIDOR
AC102
TR
F108
STOR
F107
MECHANICAL
ROOM
FM101
STOR
FTC1
TR
CTC1
MECH ROOM
CM100
CORRIDOR
CC103
MENTAL HEALTH
WAITING MENTAL
HEALTH WAITING
ROOM
C102
CLOSET
AHC2
02-31
02-31
13-03
13-02
13-03
STOR
D137
STOR
D134
TOILET
D135A
TOILET
D136A
VEST
D128
VEST
D129STOR
D123
VEST
D127
TOILET
D128B
TOILET
D126B
VEST
D126
STOR
D113
STOR
D110A
STOR
D111
STOR
DEC1
STOR
C102A
TOILET
C105A
OFFICE
C104
STOR
BEC1
BATHROOM
B111
BATHROOM
B112
ELEC RM
ATC1
TOILET
A132
TOILET
A131
STORAGE
A130PAV LOUNGE
A129
TOILET
F11A
STORAGE
FEC1
TUB/SHOWER
G147
STOR
G146E
TOILET
G135A
TOILET
G137A
BATHROOM
G133A
BATHROOM
G123A
TOILET
G120A
TOILET
G118A
TOILET
G116A
STOR
G104
TOILET
G113A
BATHROOM
G102A
BATHROOM
C100A
TOILET
E127A
TOILET
E130A
TOILET
E125A
TOILET
E135A
TOILET
E137A
TOILET
E142A
TOILET
E144A
TOILET
E123A
TOILET
E121A
TOILET
E119A
TOILET
E117A
TOILET
E100A
ROOM
A112B
ROOM
A113A1
ROOM
A106H
TOILET
A108F
COPY PRINTER
A108E
TOILET
A106A
HSK CLOSET
A107
OFFICE
A108A
OFFICE
A108D
OFFICE
A108B
OFFICE
A108C
OFFICE
A118G
SOIL
A116
TOILET
A116B
OFFICE
A118HA
TOILET
D106A
STOR
AHC3
STOR
AEC2
STOR
E134
TUB/SHOWER
ROOM
A146
TOILET
E114A
TOILET
E112A
TOILET
E110A PATIENT TOILET
E108
ELEC CLOSET
EEC1
BATHROOM
E103A
STAFF TOILET
E153
TOILET
F101B
TOILET
F110A
O2 STOR
F106
TOILET
G149
ROOM
G100.0
TOILET
G142A
TOILET
G140A
STOR
G146A
STOR
G146B
MED ROOM
G145
HSK CLOSET
G107
TOILET
G111A
TOILET
G110A
STOR
F100A3
STORAGE
F100A2
WOUNDED CARE
OFFICE
A119.2
REHAB OFFICE
A119.1
STOR
F111B
CONFERENCE
ROOM
A122A
RECREATIONAL
STORAGE
A121
OFFICE
A118HOFFICE
A118I
GERIATRIC
EXTENDED CARE
REHAB ADMIN
AREA
A118
OFFICE
A118A
MEN'S LOCKER
A1116A1
EMPLOYEE BREAK
ROOM
A119
OCCUPATIONAL
THERAPY
A103A
CHAPLAIN ADMIN
A102
STORAGE
D146
TOILET
D143A
BATHROOM
D141A
STOR
DEC2
BREAK ROOM
D106
TOILET
D106B
SOILED UTILITY
D103
CLEAN LINEN
D101
CORRIDOR
DC101
CORRIDOR
BC104
BATHROOM
B139
BATHROOM
B138
CORRIDOR
BC100
V-TEL EXAM
B101
NURSE
TREATMENT ROOM
B103
TESTING LAB
B105
OFFICE
B142
M.H. COPY PRINTER
ROOM
B108
HSK CLOSET
B140
MEDICAL
STUDENT/SWING
B113
SLEEP LAB
D136
SLEEP LAB
D138
SLEEP LAB
D135
SLEEP LAB
D133
TOILET
D133A
TOILET
D138A
VEST
DC102A
CORRIDOR
D130
RUBBER ROOM
D129A
PATIENT ROOM
D128A
PATIENT ROOM
D127A
PATIENT ROOM
D124
PATIENT ROOM
D126A
MEN'S CONG.
BATHROOM
D125
PATIENT ROOM
D122
VEST
DC101A
PATIENT ROOM
D116
PATIENT ROOM
D118
PATIENT ROOM
D114
PATIENT ROOM
D112
PATIENT LAUNDRY
D102
NURSING
PRACTITIONER
OFFICE
D104
VISITOR ROOM
D105
NURSING OFFICE
D107
CORRIDOR
D108
DAY ROOM
D110
STOR
D110B
STOR
CHC3
OFFICE
B102
OFFICE
B104
OFFICE
B106
OFFICE
B107
OFFICE
B109
OFFICE
B114
BREAK ROOM
B115
OFFICE
B116
OFFICE
B116.1
WAITING ROOM
B118
RECEPTION AREA
B117OFFICE
B137
BREAK ROOM
B136
OFFICE
B135.1
OFFICE
B135
OFFICE
B134
OFFICE
B133.1
OFFICE
B133
OFFICE
B132
OFFICE
B131
OFFICE
B130
CONF ROOM
B129
OFFICE
B128.1
OFFICE
B128
OFFICE
B127
ACOS MENTAL
HEALTH OFFICE
B126
MENTAL HEALTH
V-TEL
CONFERENCE
ROOM
B125
PSYCHIATRIST
OFFICE
B124
PCT GROUP ROOM
B123
OFFICE
B122.1
OFFICE
B122
PATIENT ACTIVITY
ROOM
B119
OFFICE
B121
CHAPLIN OFFICE
A102B
MEN'S TOILET
A101 WOMEN'S TOILET
A133
EXAM ROOM
A128
PATIENT LAUNDRY
G146C
EQUIP. STORAGE
G147A
PATIENT ROOM
G121
PATIENT ROOM
G120
PATIENT ROOM
G119
PATIENT ROOM
G118
PATIENT ROOM
G117
TOILET
G109A PATIENT ROOM
G113
NUTRITION/
STORAGE
G102
OFFICE
G100
OFFICE
G101
STOR
E140
STAFF TOILET
E154
PATIENT LAUNDRY
E151
OFFICE
E150
OFFICE
E149
DAY ROOM
E147
BREAK ROOM
A113
STOR
A112A
OFFICE
A118D
OFFICE
A118E
OFFICE
A118F
EOO
A122COFFICE POLICE
A123
OFFICE POLICE
A124
PATIENT
ADVOCATE
A127
DVA OFFICE
A125
VBA OFFICE
A126
TOILET
D121
TOILET
D120
PATIENT ROOM
E137
PATIENT ROOM
E135
PATIENT ROOM
E145
DAY ROOM
F101
THERAPY TUB
F112A
VESTIBULE
G139
PATIENT ROOM
G140
OFFICE
G103
CLEAN STRG
G108
CORRIDOR
GC101
PATIENT ROOM
G111
PATIENT ROOM
G110
MED RM/ STORAGE
G112
CORRIDOR
AC103
OFFICE
A122B
OCC THERAPY
OFFICE
A103C
OCC THERAPY
OFFICE
A103B
OCCUPATIONAL
THERAPY
A103
PATIENT LAUNDRY
D145
OFFICE
D144
SOCIAL WORKER
OFFICE
D143
OFFICE
D142
RME COORD
D141
PATIENT
RESTROOM
D140
CORRIDOR
BC102
OFFICE
B147
OFFICE
B146
OFFICE
B145
OFFICE
B144
OFFICE
B143
OFFICE
B141
CORRIDOR
BC101
HOSPICE ROOM
E122
HOSPICE ROOM
E121
HOSPICE ROOM
E120
HOSPICE ROOM
E119
BREAK ROOM
E118
HOSPICE ROOM
E114
HOSPICE ROOM
E111
PATIENT ROOM
E105
CORRIDOR
DC103
STOR
C102A1
PATIENT ROOM
D119
STORAGE
E101
PATIENT ROOM
E103
HOSPICE FAMILY
ROOM
E110
PATIENT ROOM
E136
CORRIDOR
EC103
PATIENT ROOM
E138
PATIENT ROOM
E142
PATIENT ROOM
E143
PATIENT ROOM
E144
SOCIAL WORKER
OFFICE
G109
OFFICE
G122
PATIENT ROOM
G142
PATIENT ROOM
G141
PATIENT ROOM
G143
MECH ROOM
AM100
OFFICE
C107
CORRIDOR
AC104
WOMEN'S LOCKER
A1116A
OFFICE
A118C
OFFICE
A118B
PUBLIC WOMEN'S
RESTROOM
C101A
PUBLIC MEN'S
RESTROOM
CC101
MECHANICAL
ROOM
FM100A
VEST
E129
SOILED UTILITY
E117
CLEAN UTILITY
E115
VEST
E116
STORAGE
F100A1
DIRECTOR'S SUITE
ADMIN AREA
A106
WORSHIP CHAPEL
A104
OFFICE
A106C
OFFICE
A106D
OFFICE
A106E.1 OFFICE
A106F
MEN'S LOCKER
ROOM
A113A
ROOM
A113A2
OFFICE
A111B
STOR
A111C
PATIENT ROOM
G116
VEST
G115
PATIENT ROOM
G114
PATIENT ROOM
E128
PATIENT ROOM
E130
PATIENT ROOM
E127
PATIENT ROOM
E131
PATIENT ROOM
E126
TOILET
E133B
PATIENT ROOM
E132
SMOKE SHELTER
E133C1
VEST
E133C
HOSPICE ROOM
E123
CORRIDOR
EC102
FAMILY ROOM
G136
PATIENT ROOM
G137
PATIENT ROOM
G138
RESTORATIVE
CARE OFFICE
G135
PATIENT ROOM
G133
CHAPLAIN
A102A
PATIENT ROOM
G123
NURSES STATION
D109
MED ROOM
D109A
ROOM
C100.0
STORAGE
F103
PATIENT ROOM
E125
STOR
E124
STORAGE
E100
ELECTRICAL
ROOM
EM100
CORRIDOR
E100.0
DAY ROOM
F110
RECEPTION
F101A
STOR
F105
SOCIAL WORKER
OFFICE
F104
BREAK ROOM
F109
TOILET
G150MECHANICAL
ROOM
GM100
SOIL
G144
RLRC CLOSET
G134
PATIENT DINING
ROOM
F100
PHYSICAL
THERAPY
F112
CORRIDOR
FC100
RECREATION
A120
REC STORAGE
A115A
WORK ROOM
AC102A
POLICE ADMIN
A111
OFFICE
A110
VISN T-TEL LARGE
CONFERENCE
ROOM
A109
OFFICE
A106G
LOCK WARD
DINING ROOM
C105
SOCIAL WORKER
OFFICE
D100
CORRIDOR
CC105
GROUP PRACTICE
MANAGER
D147
OFFICE
B100
OFFICE
A111D
SEWING ROOM /
UNIFORM ISSUE /
PATIENT BAGGAGE
C100
MECH ROOM
AM101A
SHARED OFFICE
C108
OCCUPATIONAL
THERAPY
F111
VEST
CC102
FRONT LOBBY
A100
VEST
A117
CORRIDOR
AC100
CLC E-WARD
NURSES STATION
E109
MED ROOM
E107
SPS STOR
E104
LINEN
E106
HSK CLOSET
E152
CLEAN UTILITY
E148
SOILED UTILITY
E102
CLEAN LINEN
STORAGE
G105
CLC G-WARD
NURSES STATION
G106
SMALL
CONFERENCE
ROOM
A106E
OFFICE
A105
POLICE AREA
A112
WAITING ROOM
A108
STORAGE
F100A
MECH ROOM
AM101
VOLUNTARY
SERVICES
A122
DAY ROOM
E133
DAY ROOM
E139
DAY ROOM
E141
HOSPICE ROOM
E113
HOSPICE ROOM
E112
BREAK ROOM
F102
DAY ROOM /
PATIENT DINING
G146
148-AD-301
09-21
13-03
13-0213-02
13-03
13-01
13-03
13-03
13-03
02-56
02-57
02-56
02-57
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLANDEMOLITION LEGEND
INDICATES BUILT ITEM TO BE REMOVED
INDICATES LIGHT FIXTURE TO BE REMOVED
INDICATES EXTENT OF ICRA CLASS SCOPE
CABLE INSTALLATION ROUTE, FIELD VERIFY
CONDITIONS PRIOR TO COMMENCEMENT OF
WORK, SEE TELECOMM DRAWINGS FOR
EXTENT OF WORK
DEMOLITION GENERAL NOTES
1. SEE G SERIES SHEETS FOR ALL DEMOLITION NOTES & HAZARDOUS
MATERIAL NOTES
2. IN HOSPITAL OCCUPANCY, CONTRACTOR ARE TO USE A
CONSTRUCTION CONTAINMENT CUBE WITH HEPA VACUUM TO
MAINTAIN NEGATIVE PRESSURE AS A MEANS TO ACCESS AREAS
ABOVE CEILING TILES. THIS INCLUDES ALL PATIENT CORRIDORS AND
ALL ACUTE CARE PATIENT AREAS. THIS IS IN CONJUNCTION WITH
THE HOSPITALS INFECTION PREVENTION MEASURES AND ICRA
PROTOCOLS.
3. MAINTAIN FIRE SUPPRESSION SYSTEM OPERATIONAL DURING
CONSTRUCTION WORK. FIRE SUPPRESSION CONTRACTOR TO
REMOVE DOWNWARD HEADS AND TURN UPWARS, PROVIDE NEW
FIRE SUPPRESSION HEAD IN TELECOMMUNICATION ROOMS (TR).
WORK TO BE CONDUCTED WITHIN ONE WORKING SHIFT. SEE
ADDITIONAL PROJECT NOTES ON COVER SHEET.
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t M e a d e
S D
/2
B ld g r2
.r v t
-0
-2
:3
:0
148-AD-201
148-LEVEL 1 DEMOLITION PLAN
GDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 148
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/16" = 1'-0"1
LEVEL 1 DEMOLITION FLOOR PLAN
02-31 SEE TELECOM PLANS FOR PATH LOCATION. PREP CEILING FOR SURFACE MOUNT CONDUIT IN
LOCATIONS W/O ACOUSTIC CEILING TILES.
02-56 CORE DRILL THROUGH CONCRETE SHEAR WALL TO INSTALL MECHANICAL DUCT WORK, SEE
STRUCTRUAL DRAWINGS
02-57 CONTRACTOR TO ROUTE CONDUIT IN LEAST DESTRUCTIVE MANNER TO LOCATIONS AS
INDICATED IN TELECOMMUNICATION DRAWINGS, CONTRACTOR TO BE RESPONSIBLE TO VISIT
SITE AND UNDERSTAND ROUTING AND MATERIAL TREATMENT; PATCH AND FINISH TO MATCH
EXISTING MATERIALS; TYPICAL AT ALL DATA DROP LOCATIONS
09-21 REMOVE AND RE-INSTALL CEILING TILES AND OTHER CEILING MOUNTED DEVICES AS NEEDED
FOR INSTALLATION OF CABLES AND CONDUITS ABOVE CEILING AS PER TELECOM DRAWINGS,
REPLACE ALL DAMANGED TILES TO MATCH EXISTING AND REINSTALL ALL DEVICES AS NEEDED.
DO NOT LEAVE CEILING TILES UNINSTALLED AND UNATTENDED PAST DURATION OF WORKING
SHIFT. CONTINUOUSLY REINSTALL TILES TO PROVIDE SEALED SMOKE ASSEMBLY. SEE COVER
SHEET FOR ADDITIONAL NOTES UNDER "TEMPORARY FIRE & SMOKE PROTECTION"
13-01 ICRA CLASS I, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND WORKING HOURS
RESTRICTIONS
13-02 ICRA CLASS II, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND WORKING HOURS
RESTRICTIONS
13-03 ICRA CLASS III, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND WORKING HOURS
RESTRICTIONS
KEYNOTES
FC
P
ORGANIZATIONAL
IMPROVEMENT
OFFICE
C106
OFFICE
C106B
TR
C106A
CORRIDOR
CC101
CORRIDOR
CC100
CORRIDOR
CC104
02-03
02-09
02-30
02-09
02-04
02-17
13-06
13-06
02-24
23-08
SCALE: 1/4" = 1'-0"
4' 3' 2' 1' 4' 8'0'
NORTH
TR
A114A
CORRIDOR
AC101
SOIL HOLD
ATC2
REC STORAGE
A115
CORRIDOR
AC102
CLOSET
AHC2
02-03
02-03
02-27
02-43
02-17
02-44 13-06
02-46
02-24
02-47
02-47
02-08
23-08
SCALE: 1/4" = 1'-0"
4' 3' 2' 1' 4' 8'0'
NORTH
TR
F108
MECHANICAL
ROOM
FM101
STOR
FTC1
STOR
F107
02-03
02-30
02-17
02-21
02-45
02-46
13-06
02-0702-47
02-17
23-08
SCALE: 1/4" = 1'-0"
4' 3' 2' 1' 4' 8'0'
NORTH
TR
CTC1
MECH ROOM
CM100
CORRIDOR
CC103
MENTAL HEALTH
WAITING MENTAL
HEALTH WAITING
ROOM
C102
02-45 02-17
SCALE: 1/4" = 1'-0"
4' 3' 2' 1' 4' 8'0'
NORTH
HATCH INDICATES AREA NOT IN SCOPE OF WORK
INDICATES BUILT ITEM TO BE REMOVED
INDICATES LIGHT FIXTURE TO BE REMOVED
DEMOLITION LEGEND
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
DEMOLITION GENERAL NOTES
1. SEE G SERIES SHEETS FOR ALL DEMOLITION NOTES & HAZARDOUS
MATERIAL NOTES
2. IN HOSPITAL OCCUPANCY, CONTRACTOR ARE TO USE A
CONSTRUCTION CONTAINMENT CUBE WITH HEPA VACUUM TO
MAINTAIN NEGATIVE PRESSURE AS A MEANS TO ACCESS AREAS
ABOVE CEILING TILES. THIS INCLUDES ALL PATIENT CORRIDORS AND
ALL ACUTE CARE PATIENT AREAS. THIS IS IN CONJUNCTION WITH
THE HOSPITALS INFECTION PREVENTION MEASURES AND ICRA
PROTOCOLS.
3. MAINTAIN FIRE SUPPRESSION SYSTEM OPERATIONAL DURING
CONSTRUCTION WORK. FIRE SUPPRESSION CONTRACTOR TO
REMOVE DOWNWARD HEADS AND TURN UPWARS, PROVIDE NEW
FIRE SUPPRESSION HEAD IN TELECOMMUNICATION ROOMS (TR).
WORK TO BE CONDUCTED WITHIN ONE WORKING SHIFT. SEE
ADDITIONAL PROJECT NOTES ON COVER SHEET.
OFFICE
C107
ORGANIZATIONAL
IMPROVEMENT
OFFICE
C106
SHARED OFFICE
C108
WORSHIP CHAPEL
A104
CORRIDOR
CC100
CORRIDOR
AC100
02-05
02-20
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t M e a d e
S D
/2
B ld g r2
.r v t
-0
-2
:3
:0
148-AD-301
148-ENLARGED DEMOLITION
DRAWINGSGDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 148
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/4" = 1'-0"3
LEVEL 1 C106A ENLARGED DEMOLITION PLAN
1/4" = 1'-0"5
LEVEL 1 A114A ENLARGED DEMOLITION PLAN
1/4" = 1'-0"4
LEVEL 1 F108 ENLARGED DEMOLITION PLAN
1/4" = 1'-0"2
LEVEL 1 CTC1 ENLARGED DEMOLITION PLAN
02-03 CAREFULLY REMOVE EXISTING DOOR, FRAME AND HARDWARE, RETURN TO
OWNER.
02-04 DEMO CARPET, BASE, AND ADHESIVES; PREPARE FLOOR FOR NEW STATIC
DISSIPATIVE RESILIENT FLOORING AND BASE
02-05 DEMO CABINETRY, COUNTER, PLUMBING FIXTURE, WALL MOUNTED ACCESSORIES,
AND DIVIDING WALL
02-07 PIPE PENETRATION THROUTH EXISTING WALL; PREPARE FOR PLUMBING PIPE
INSTALLATION; COORDINATE WITH MECHANICAL DRAWINGS
02-08 CAREFULLY REMOVE CEILING TILES AND OTHER CEILING MOUNTED DEVICES,
CAREFULLY STORE IN NON-TRAFFICKED AREA AND PREPARE FOR REINSTALLATION
AT COMPLETION OF WORK
02-09 DEMO WALL AS REQUIRED TO RECEIVE NEW DOOR AND FRAME
02-17 PATCH/REPAIR ALL WALL DAMAGE AND PREPARE FOR NEW FINISHES, TYP. PRIME
LOCATIONS OVERHEAD
02-20 DEMO FLOOR & FLOOR BASE, PATCH WALLS, PREPARE FOR NEW FINISHES
02-21 DEMO EXISTING PLUMBING FIXTURES, WALL TILE IF ANY, AND PLUMBING
ACCESSORIES. CAP AND TERMINATE PER PLUMBING DRAWINGS.
02-24 CORE DRILL THROUGH MASONRY WALL AS REQUIRED, PROVIDE OPENING 1/2"
LARGER THAN CONDUIT SIZE, SEE TELECOM DRAWINGS FOR CONDUIT SIZE AND
QUANTITES. PATCH AND ACOUSTICALLY SEAL ALL NEW PENETRATIONS. APPLY
APPROPRIATE HILTI FIRE RATED SEAL FOR TYPE OF PENETRATION.
02-27 DEMO EXISTING TILE FLOOR, APPLY SELF LEVELING COMPOUND AND PREPARE TO
RECEIVE NEW FLOORING.
02-30 DEMO EXISTING CEILING TILE, LIGHT FIXTURES AND ANY CEILING MOUNTED
DEVICES; REMOVE EXISTING SPRINKLER HEADS AND TURN UP DISCHARGE PIPE,
PROVIDE NEW FIRE SUPPRESSION HEADS FOR EXPOSED CONDITIONS
02-43 SAW CUT OPENING IN EXISTING CONCRETE SHEAR WALL, SEE STRUCTURAL
DRAWINGS; PREPARE TO RECEIVE NEW DOOR
02-44 DEMO EXISTING CEILING TILE, LIGHT FIXTURES AND ANY CEILING MOUNTED
DEVICES; PREPARE TO RECEIVE NEW FINISHES AND ACCESSORIES, SEE MEP
DRAWINGS
02-45 DEMO WALL BASE AND PREPARE WALLS TO RECEIVE NEW FINISHES
02-46 PROTECT EXISTING CARPET DURING CONSTRUCTION, REMOVED CARPET TILE IN TR
AREA TO BE SALVAGED AND REUSED WHERE NEEDED; RETURN TO OWNER FOR
STORAGE
02-47 REMOVE UNUSED CONDUITS FROM FLOOR, PATCH AND FILL, APPLY FLOOR
LEVELING AS REQUIRED, PREPARE TO RECEIVE NEW FLOORING
13-06 INFECTION PREVENTION, FIRE RATED, 6MM PLASTIC BARRIER SEALED TOP,
BOTTOM, AND SIDES. PROVIDE VESTIBULE AREA FOR GOWNING AND UNGOWNING
AND NEGATIVE PRESSURE WITHIN CONSTRUCTION AREA IN ICRA CLASS IV. SEE
SPECS FOR OTHER ICRA CONSTRUCTION REQUIREMENTS; COORDINATE LOCATION
OF TEMPORARY INFECTION PREVENTION BARRIER ITHE C.O.R. AND INFECTION
PREVENTION REPRESENTATIVE.
23-08 NEW REFRIGERANT PIPE LINES ROUTING SHOWN FOR REFERENCE ONLY. SEE
MECHANICAL DRAWINGS FOR ACTUAL ROUTING; CONTRACTOR TO REMOVE CEILING
TILES ALONG ROUTE OUTSIDE OF TR'S AND REPLACE WITHIN WORKING SHIFT.
CONDUCT INFECTION PREVENTION MEASURES AS SPECIFIED.
KEYNOTES
EXTERIOR SPACE
1/4" = 1'-0"1
C108 CONFERENCE ROOM DEMOLITION PLAN
NEW TR CONFIGURATION
SHOWN YELLOW
T296-AD-201
13-01
NORTH
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
ROOM
ROOM
102A
LAUNDRY
101A
TR
ROOM
C100
ROOM
ROOM
102B
ROOM
RESTROOM
201A
ROOM
ROOM
202A
ROOM
201D
ROOM
ROOM
CORRIDOR
C200
ROOM
13-03
02-56
DEMOLITION LEGEND
KEYNOTES
INDICATES BUILT ITEM TO BE REMOVED
INDICATES LIGHT FIXTURE TO BE REMOVED
INDICATES EXTENT OF ICRA CLASS SCOPE
DEMOLITION GENERAL NOTES
CABLE INSTALLATION ROUTE, FIELD VERIFY
CONDITIONS PRIOR TO COMMENCEMENT OF
WORK, SEE TELECOM DRAWINGS FOR
EXTENT OF WORK
1. SEE G SERIES SHEETS FOR ALL DEMOLITION NOTES & HAZARDOUS
MATERIAL NOTES
2. MAINTAIN FIRE SUPPRESSION SYSTEM OPERATIONAL DURING
CONSTRUCTION WORK. FIRE SUPPRESSION CONTRACTOR TO REMOVE
DOWNWARD HEADS AND TURN UPWARS, PROVIDE NEW FIRE
SUPPRESSION HEAD IN TELECOMMUNICATION ROOMS (TR). WORK TO
BE CONDUCTED WITHIN ONE WORKING SHIFT. SEE ADDITIONAL
PROJECT NOTES ON COVER SHEET.
VA MEDICAL CENTER
FORT MEADE, SD
PLAN
NORTH
PROJECT KEY PLAN
TRUE
NORTH
LAUNDRY
101A
C100
02-42
02-42
EXTENT OF TR ADDITION
DEMO EXISTING CONCRETE SLAB
REMOVE EXISTING HOSE BIB AND
RELOCATE TO NEW WALL
02-15
DEMO EXISTING SIDING FROM
FOUNDATION TO SOFFIT EXPOSING
SUBSTRATE, FULL PERIMETER OF
NEW CONSTRUCTION
13-06
SCALE: 1/4" = 1'-0"
4' 3' 2' 1' 4' 8'0'
NORTH
DEMO EXISTING SIDING, PREPARE
FOR INSTALLATION OF NEW SIDING
MATERIAL ON THIS FACE
PROPOSED NEW TR LOCATION
EXISTING TR TO BE UPDATED
ROOM ALLOCATION LEGEND
ABANDONED ROOM
ROOM TO REMAIN, NO WORK
PROPOSED EXPANSION TO TR
REMODEL REQUIRED DUE TO EHRM IMPACT
EXTENT OF NEW EXPANSION SHOWN
DASHED
EXISTING SLOPED ASPHALT
SHINGLE ROOFS
DEMO EXISTING ASPHALT SHINGLE ROOF,
RAFTERS AND CEILING; PROTECT FROM
ELEMENTS DURING CONSTRUCTION
NORTH
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
(E) SHED ROOF TO REMAIN; PATCH
INTERFACE WITH DEMOLISHED ROOF
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V
A M e d ic a l C e n te r
F t M e a d e S
D /2
B ld g
T r2
.r v t
-0
-2
:5
:1
T296-AD-201
T296-LEVEL 1 DEMOLITION PLAN
GDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG T296
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/8" = 1'-0"2
LEVEL 1 DEMOLITION FLOOR PLAN
02-15 PROTECT EXISTING WINDOW DURING CONSTRUCTION
02-42 DEMO EXISTING WINDOW AND PERIMETER TRIM, INFIL WITH METAL STUDS AND
5/8" TYPE 'X' GYSPUM AS REQUIRED TO MATCH EXISTING WALL THICKNESS;
PREPARE TO RECEIVE NEW FINISHES.
02-56 CONTRACTOR TO ROUTE CONDUIT IN LEAST DESTRUCTIVE MANNER TO
LOCATIONS AS INDICATED IN TELECOMMUNICATION DRAWINGS, CONTRACTOR
TO BE RESPONSIBLE TO VISIT SITE AND UNDERSTAND ROUTING AND MATERIAL
TREATMENT; PATCH AND FINISH TO MATCH EXISTING MATERIALS; TYPICAL AT
ALL DATA DROP LOCATIONS
13-01 ICRA CLASS I, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND WORKING
HOURS RESTRICTIONS
13-03 ICRA CLASS III, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND WORKING
HOURS RESTRICTIONS
13-06 INFECTION PREVENTION, FIRE RATED, 6MM PLASTIC BARRIER SEALED TOP,
BOTTOM, AND SIDES. PROVIDE VESTIBULE AREA FOR GOWNING AND
UNGOWNING AND NEGATIVE PRESSURE WITHIN CONSTRUCTION AREA IN ICRA
CLASS IV. SEE SPECS FOR OTHER ICRA CONSTRUCTION REQUIREMENTS
1/4" = 1'-0"1
ENLARGED DEMOLITION PLAN
1/8" = 1'-0"3
DEMOLITION ROOF PLAN
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
NORTH
MASON SHOP
102A BREAK ROOM
PAINT SHOP
LUMBER STORAGE
PAINT BOOTH
103A
OFFICE
103B
TOILET
101A
STORAGE
100B
OFFICE
100A
ELECT
100A1
LOCK SHOP
100C
CARPENTER SHOP
SEE TELECOM DRAWINGS
FOR DEMO OF TELECOM
PANEL
26-09
13-01
26-10
01-01
C L E
A R
A N
C E
CLEARANCE
3' - 0"
09-10
09-24
09-21
23-05
23-05
23-08
03-01
26-13
ROOM
100D
FLOOR PLAN NOTESFLOOR PLAN NOTES
1. SEE G SERIES SHEETS FOR BALANCE OF PLAN GENERAL NOTES.
2. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS
FOR ADDITIONAL INFORMATION. ALL INFORMATION REGARDING
EXISTING CONDITIONS IS BASED UPON OWNER-SUPPLIED
DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD CONDITIONS.
3. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND ALL
WALL MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE
LOCATIONS.
4. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE OF
STUD, UNLESS OTHERWISE NOTED.
5. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND
REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.
6. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO
PROVIDE SUITABLE SUBSTRATE FOR FINISHES.
7. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS REQUIRING ADA
ACCESS CONTROL.
8. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND
BOTTOM, AND PENETRATIONS, AND INSTALL PUTTY PADS AROUND
ELECTRICAL BOXES WHERE PARTITION CONTAINS ACOUSTICAL
INSULATION.
9. ALL TELECOMMUNICATION ROOMS ARE TO HAVE EXPOSED
STRUCTURE UNLESS NOTED OTHERWISE, NO CEILINGS SPECIFIED.
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
FLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
STRIP LIGHT FIXTURE, REF ELEC DRAWINGS
KEYNOTES
EXP
EXP EXP
EXP
MASON SHOP
102A
BREAK ROOM
PAINT SHOP
LUMBER STORAGE
PAINT BOOTH
103A
OFFICE
103B
TOILET
101A
STORAGE
100B
OFFICE
100A
ELECT
100A1
LOCK SHOP
100C
CARPENTER SHOP
09-21
23-08
26-13
09-21
ROOM
100D
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t
M e a d e S
D /2
B ld g r2
.r v t
-0
-2
:3
:5
40-AE-201
40-FLOOR PLANS
GDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 40
Project Director
JPR/SGTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/8" = 1'-0"1
LEVEL 1 FLOOR PLAN
01-01 CLEAN UP AREA AROUND PROPOSED WALL MOUNTED CABINET LOCATION;
COORDINATE WITH C.O.R. FOR RELOCATION OR REMOVAL OF INSTALLATION
OBSTRUCTING ITEMS.
03-01 NEW HOUSEKEEPING PAD, COORDINATE WITH MECHANICAL DRAWINGS FOR
SIZE AND CIVIL DRAWINGS FOR DETAILS
09-10 PAINT FULL LENGTH OF WALL TO NEAREST EXTERIOR OR INTERIOR
CORNER, COLOR TO MATCH EXISTING WALLS.
09-21 REMOVE AND RE-INSTALL CEILING TILES AND OTHER CEILING MOUNTED
DEVICES AS NEEDED FOR INSTALLATION OF CABLES AND CONDUITS ABOVE
CEILING AS PER TELECOM DRAWINGS, REPLACE ALL DAMANGED TILES TO
MATCH EXISTING AND REINSTALL ALL DEVICES AS NEEDED. DO NOT LEAVE
CEILING TILES UNINSTALLED AND UNATTENDED PAST DURATION OF
WORKING SHIFT. CONTINUOUSLY REINSTALL TILES TO PROVIDE SEALED
SMOKE ASSEMBLY.
09-24 PATCH DAMAGED WALLS PREPARE TO RECEIVE NEW FINISHES.
13-01 ICRA CLASS I, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND
WORKING HOURS RESTRICTIONS
23-05 MECHANICAL UNITS, SEE MECH DRAWINGS FOR SIZE AND SPECS
23-08 NEW REFRIGERANT PIPE LINES ROUTING SHOWN FOR REFERENCE ONLY.
SEE MECHANICAL DRAWINGS FOR ACTUAL ROUTING; CONTRACTOR TO
REMOVE CEILING TILES ALONG ROUTE OUTSIDE OF TR'S AND REPLACE
WITHIN WORKING SHIFT. CONDUCT INFECTION PREVENTION MEASURES AS
SPECIFIED.
26-09 30" CLEARANCE AT WALL MOUNTED SERVER RACK SHOWN DASHED
26-10 WALL MOUNTED TELECOM CABINET, SEE TELECOM DRAWINGS
26-13 NEW CABLE TRAY ROUTING SHOWN FOR REFERENCE ONLY. SEE
TELECOMMUNICATION DRAWINGS FOR ACTUAL ROUTING. CONDUCT
INFECTION PREVENTION MEASURES AS SPECIFIED.
1/8" = 1'-0"2
LEVEL 1 REFLECTED CEILING PLAN
UP
UP
UP
UP UP UP UP
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
NORTH
BOILER ROOM
B104
VAULT
B105
DRUG SUPPLY
B103
STORAGE
B101
ELEVATOR
B102
ELEVATOR ROOM
B102
E EXT STAIRW EXT STAIR
26-09
13-01
SEE TELECOM DRAWINGS FOR
EXTENT OF WORK; PATCH AND
CLEAN ANY DEMO WORK
ASSOCIATED WITH REMOVAL OF
TELECOM DEVICES.
26-10
01-01
CLEAR
2' - 6"
C L E
A R
A N
C E
23-05
23-08
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
NORTH
CORRIDOR
OFFICE
CONFERENCE
ROOM
OFFICE
RECEIVING
ELEVATOR
MEN
HOSEKEEPING
WOMEN
OFFICE
100A
CORRIDOR
C100
ENTRY / OFFICE
100B
OFFICE
100C
STORAGE
101A
ROOM
101B
ROOM
101C
OFFICE
101D
ENCLOSED ROOM
104A
13-01
LANDING
LD1
PLATFORM
P2
09-21
03-01
23-05
23-08
26-13
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
NORTH
13-01
STORAGE
STORAGE
ELEVATOR
FLOOR PLAN NOTESFLOOR PLAN NOTES
1. SEE G SERIES SHEETS FOR BALANCE OF PLAN GENERAL NOTES.
2. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS
FOR ADDITIONAL INFORMATION. ALL INFORMATION REGARDING
EXISTING CONDITIONS IS BASED UPON OWNER-SUPPLIED
DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD CONDITIONS.
3. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND ALL
WALL MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE
LOCATIONS.
4. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE OF
STUD, UNLESS OTHERWISE NOTED.
5. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND
REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.
6. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO
PROVIDE SUITABLE SUBSTRATE FOR FINISHES.
7. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS REQUIRING ADA
ACCESS CONTROL.
8. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND
BOTTOM, AND PENETRATIONS, AND INSTALL PUTTY PADS AROUND
ELECTRICAL BOXES WHERE PARTITION CONTAINS ACOUSTICAL
INSULATION.
9. ALL TELECOMMUNICATION ROOMS ARE TO HAVE EXPOSED
STRUCTURE UNLESS NOTED OTHERWISE, NO CEILINGS SPECIFIED.
VA MEDICAL CENTER
FORT MEADE, SD
NORTH
PROJECT KEY PLAN
FLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
STRIP LIGHT FIXTURE, REF ELEC DRAWINGS
KEYNOTES
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
IM
/2
V A
M e d ic a l C e n te r
F t
M e a d e S
D /2
B ld g r2
.r v t
-0
-2
:3
:1
46-AE-201
46-FLOOR PLANS
GDM
1000 W STEUBEN ST. UNIT 3
BINGEN, WA 98605
541.436.4723
ADAM GODDIN, PE
A&E DESIGN
124 NORTH 29TH STREET, #100
BILLINGS, MONTANA 59101
406.248.2633
T. MARCELLO PIERROTTET, AIA
EHRM INFRASTRUCTURE
UPGRADES
FORT MEADE, SOUTH DAKOTA
568-21-701
BLDG 46
Project Director
JPRTMP04/15/2022
100% CONSTRUCTION
DOCUMENTS
ARCHITECTA/E:
FULLY SPRINKLERED
1/8" = 1'-0"1
BASEMENT FLOOR PLAN
1/8" = 1'-0"2
LEVEL 1 FLOOR PLAN
1/8" = 1'-0"3
LEVEL 2 FLOOR PLAN
01-01 CLEAN UP AREA AROUND PROPOSED WALL MOUNTED CABINET LOCATION;
COORDINATE WITH C.O.R. FOR RELOCATION OR REMOVAL OF INSTALLATION
OBSTRUCTING ITEMS.
03-01 NEW HOUSEKEEPING PAD, COORDINATE WITH MECHANICAL DRAWINGS FOR
SIZE AND CIVIL DRAWINGS FOR DETAILS
09-21 REMOVE AND RE-INSTALL CEILING TILES AND OTHER CEILING MOUNTED
DEVICES AS NEEDED FOR INSTALLATION OF CABLES AND CONDUITS ABOVE
CEILING AS PER TELECOM DRAWINGS, REPLACE ALL DAMANGED TILES TO
MATCH EXISTING AND REINSTALL ALL DEVICES AS NEEDED. DO NOT LEAVE
CEILING TILES UNINSTALLED AND UNATTENDED PAST DURATION OF
WORKING SHIFT. CONTINUOUSLY REINSTALL TILES TO PROVIDE SEALED
SMOKE ASSEMBLY.
13-01 ICRA CLASS I, SEE SPEC SECTION 01 35 26 FOR REQUIREMENTS AND
WORKING HOURS RESTRICTIONS
23-05 MECHANICAL UNITS, SEE MECH DRAWINGS FOR SIZE AND SPECS
23-08 NEW REFRIGERANT PIPE LINES ROUTING SHOWN FOR REFERENCE ONLY.
SEE MECHANICAL DRAWINGS FOR ACTUAL ROUTING; CONTRACTOR TO
REMOVE CEILING TILES ALONG ROUTE OUTSIDE OF TR'S AND REPLACE
WITHIN WORKING SHIFT. CONDUCT INFECTION PREVENTION MEASURES AS
SPECIFIED.
26-09 30" CLEARANCE AT WALL MOUNTED SERVER RACK SHOWN DASHED
26-10 WALL MOUNTED TELECOM CABINET, SEE TELECOM DRAWINGS
26-13 NEW CABLE TRAY ROUTING SHOWN FOR REFERENCE ONLY. SEE
TELECOMMUNICATION DRAWINGS FOR ACTUAL ROUTING. CONDUCT
INFECTION PREVENTION MEASURES AS SPECIFIED.
OS
UP
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
PLAN
NORTH
STORAGE AREA
B101
STORAGE AREA
B100
13-01
26-09
STAIR
B000
STORAGE AREA
B102
STORAGE AREA
B102A
01-01
26-10
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
PLAN
NORTH
13-01
RESTROOM
RESTROOM
202A
VESTIBULE
SAFETY
SUPERVISOR
OFFICE
201B
STORAGE
201A
SAFETY OFFICE
POST OFFICE
POST OFFICE
102A
POST OFFICE
VESTIBULE
VESTIBULE
P1
LOADING DOCK
P2
BREAK ROOM
26-13
FLOOR PLAN NOTESFLOOR PLAN NOTES
1. SEE G SERIES SHEETS FOR BALANCE OF PLAN GENERAL NOTES.
2. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS
FOR ADDITIONAL INFORMATION. ALL INFORMATION REGARDING
EXISTING CONDITIONS IS BASED UPON OWNER-SUPPLIED
DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD CONDITIONS.
3. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND ALL
WALL MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE
LOCATIONS.
4. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE OF
STUD, UNLESS OTHERWISE NOTED.
5. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND
REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS.
6. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO
PROVIDE SUITABLE SUBSTRATE FOR FINISHES.
7. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS REQUIRING ADA
ACCESS CONTROL.
8. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND
BOTTOM, AND PENETRATIONS, AND INSTALL PUTTY PADS AROUND
ELECTRICAL BOXES WHERE PARTITION CONTAINS ACOUSTICAL
INSULATION.
9. ALL TELECOMMUNICATION ROOMS ARE TO HAVE EXPOSED
STRUCTURE UNLESS NOTED OTHERWISE, NO CEILINGS SPECIFIED.
VA MEDICAL CENTER
FORT MEADE, SD
TRUE
NORTH
PROJECT KEY PLAN
FLOOR PLAN LEGEND
CARD READER, REF TELECOM DRAWINGS
DATA PORT, REF TELECOM DRAWINGS
OUTLET, REF ELEC DRAWINGS
WIRELESS ACCESS POINT, REF TELECOM
DRAWINGS
ELEC PANEL, REF ELEC DRAWINGS
STRIP LIGHT FIXTURE, REF ELEC DRAWINGS
KEYNOTES
RESTROOM
RESTROOM
202A
VESTIBULE
SAFETY
SUPERVISOR
OFFICE
201B
STORAGE
201A
SAFETY OFFICE
POST OFFICE
POST OFFICE
102A
POST OFFICE
VESTIBULE
BREAK ROOM
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
PLAN
NORTH
STORAGE AREA
B101
STORAGE AREA
B100
STAIR
B000
STORAGE AREA
B102
STORAGE AREA
B102A
SCALE: 1/8" = 1'-0"
8' 6' 4' 2' 8' 16'0'
PLAN
NORTH
OTS OTS
OTS
OTS
U.S. Department of Veterans Affairs
PROJECT NUMBER
BUILDING NUMBER
DRAWING NUMBER
PROJECT TITLE
LOCATION
ISSUE DATE CHECKED BY DRAWN BY
DRAWING TITLE
APPROVED:
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FLS
PROGRAM
CONTRACTING
ACTIVITY
CENTRAL (PCAC)
B
This is the start of the file's text. The full file is on GovTribe.