Attachment 6 05_100_ BID SET Fire Protection Drawings.pdf

PDF 2 MB Posted

Attached to
Y1DZ--VHA MINOR CONSTRUCTION Project 589-704 Infill of Building 26 for Dental Clinics, New Police Office, and Renovate for Specialty Care Services
Solicitation number
36C77624R0027
Issued by

About this file

This solicitation is for a construction project to construct an infill of Building 26 for dental clinics, a new police office, and renovate specialty care services at the Wichita VA Medical Center in Wichita, Kansas. The solicitation seeks to construct an infill space for dental clinics, a new police office, and renovate existing space for specialty care services including gastrointestinal, rheumatology, and neurology clinics. The work includes construction drawings, fire protection, fire alarms, and fire suppression. The period of performance is 720 calendar days. The Department of Veterans Affairs Technology Acquisition Center Austin issued the solicitation.

View the file

Other files

File Type Posted
36C77624R0027 0005.docx DOCX document
SA031 - Pad Details.pdf PDF
589-704 AE Addendum 01.pdf PDF
S05-589-704 RFIs - Technical Questions_RESPONSES.docx DOCX document
36C77624R0027 0004.docx DOCX document
36C77624R0027 0003.docx DOCX document
36C77624R0027 0002.docx DOCX document
589-704 PreBid Sign In Sheet.pdf PDF
03 Volume 589-704 Spec v2.pdf PDF
36C77624R0027 0001.docx DOCX document
Final Geotech Report B26.pdf PDF
Attachment 15 Bldg 26 - Ground Floor - Asbestos Survey.pdf PDF
Attachment 12 02 Volume 589-704 Spec.pdf PDF
Attachment 19 - Site Visit Instructions.docx DOCX document
Attachment 9 08_100_ BID SET Electrical Drawings.pdf PDF
Attachment 3 02_100_ BID SET Civil Drawings.pdf PDF
Attachment 4 03_100_ BID SET Structural Drawings.pdf PDF
Attachment 11 01 Volume 589-704 Spec_R1.pdf PDF
Attachment 7 06_100_ BID SET Plumbing Drawings.pdf PDF
Attachment 2 01_100_ BID SET Environmental Drawings.pdf PDF
Attachment 14 Bldg 26 - First Floor - Asbestos Survey.pdf PDF
Attachment 13 03 Volume 589-704 Spec.pdf PDF
Attachment 16 Kansas Tax Language - 1.26.2023 - FINAL.docx DOCX document
Attachment 8 07_100_ BID SET Mechanical Drawings.pdf PDF
Attachment 17 WD Sedgwick 01192024.pdf PDF
Attachment 10 09_100_ BID SET Technology Drawings.pdf PDF
36C77624R0027_1.docx DOCX document
Attachment 18 - VA Handbook 6500.6 Appendix C.pdf PDF
Attachment 5 04_100_ BID SET Architectural Drawings.pdf PDF
Attachment 1 - 00_100_ BID SET General Drawings.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL:

1. THE CONTRACTOR SHALL CAREFULLY REVIEW ALL APPLICABLE DESIGN CRITERIA,

THESE DRAWINGS, AND THE PROJECT SPECIFICATIONS FOR IMPORTANT

QUALIFICATION, DEFINITION, SUBMITTAL, PRODUCT, INSTALLATION, AND TESTING

REQUIREMENTS.

2. ALL SUBMITTALS, INSTALLATION, AND TESTING SHALL BE COMPLETED IN A NEAT,

WORKMAN-LIKE MANNER.

3. PRODUCT, DESIGN, INSTALLATION, AND TESTING ALTERNATE APPROACHES AND/OR

SUBSTITUTIONS WILL BE CONSIDERED BY THE ENGINEER IF THE CONTRACTOR

PROVIDES WRITTEN, WELL-DOCUMENTED, ENGINEERING-BASED SUBSTANTIATION

FOR PROPOSED ALTERNATIVE.

4. BEFORE WORK BEGINS, THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE

AVAILABLE CAPACITY OF THE EXISTING FIRE ALARM PANEL. IF AVAILABLE CAPACITY

IS NOT ADEQUATE FOR THE EXPECTED NEW NOTIFICATION APPLIANCES AND

INITIATING DEVICES THE CONTRACTOR SHALL ALERT THE COR FOR FURTHER

DIRECTION.

APPLICABLE CODES AND STANDARDS:

1. VA FIRE PROTECTION DESIGN MANUAL EIGHTH EDITION - JUNE 2021

2. NFPA 70 NATIONAL ELECTRIC CODE (2020)

3. NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE (2022)

4. NFPA 101 (2021)

5. INTERNATIONAL BUILDING CODE (2021)

AUDIBILITY DESIGN:

1. BECAUSE OF UNPREDICTABLE BACKGROUND NOISES AND PROJECT CONDITIONS,

THE AUDIBILITY DESIGN GOALS SHALL BE CONFIRMED BY MEASUREMENT WITH

CALIBRATED TEST EQUIPMENT. IF RESULTS INDICATE THAT ADDITIONAL

NOTIFICATION APPLIANCES ARE REQUIRED, THE CONTRACTOR SHALL ADD THEM AT

NO ADDITIONAL COST.

2. SPEAKERS MAY BE FIELD-LOCATED WITHIN 6 FT OF THE LOCATION INDICATED ON THE

APPROVED DESIGN WITHOUT CONSULTING THE ENGINEER.

3. DENTAL TREATMENT ROOMS WILL BE DESIGNED AROUND PRIVATE MODE

NOTIFICATION IN ACCORDANCE WITH NFPA 72. PRIVATE-MODE SIGNALING WILL BE

PROVIDED TO NURSE STATIONS TO ENSURE EMERGENCY ACTION IS CONDUCTED IN

THE EVENT OF A FIRE ALARM.

VISUAL NOTIFICATION DESIGN:

1. CLEAR STROBES SHALL BE PROVIDED WHERE INDICATED ON THE APPROVED

DESIGN.

2. STROBES MAY BE FIELD-LOCATED WITHIN 3 FT OF THE LOCATION INDICATED ON THE

APPROVED DESIGN WITHOUT CONSULTING THE ENGINEER. CONSULT WITH

ENGINEER PRIOR TO RELOCATING STROBES MORE THAN 3 FT.

INITIATING DEVICES:

1. INITIATING DEVICES MAY BE FIELD-LOCATED WITHIN 3 FT OF THE LOCATION

INDICATED ON THE APPROVED DESIGN WITHOUT CONSULTING THE ENGINEER.

CONSULT WITH ENGINEER PRIOR TO RELOCATING INITIATING DEVICES MORE THAN 3

FT.

CIRCUITS AND CONDUIT:

1. ALL CIRCUITS SHALL BE PROVIDED IN CONDUIT IN ACCORDANCE WITH NFPA 70 AND

THE CONDUIT LISTING.

2. NEW SIGNALING LINE CIRCUITS AND NOTIFICATION APPLIANCE CIRCUITS SHALL BE

ARRANGED SO THAT A SINGLE FAULT DOES NOT CAUSE THE LOSS OF ADDRESSABLE

DEVICES ON MORE THAN ONE SMOKE COMPARTMENT.

3. WIRING SHALL BE INSTALLED IN METAL RACEWAY. PER VA DESIGN MANUAL THIS IN

COMBINATION WITH BUILDINGS PROTECTED THROUGHOUT BY SPRINKLERS SHALL BE

CONSIDERED TO MEET THE REQUIREMENTS FOR PATHWAY SURVIVABILITY LEVEL 2 IN

ACCORDANCE WITH NFPA 72 AND VA AUTHORITY HAVING JURISDICTION.

4. SPEAKERS AND STROBES SHALL BE ARRANGED TO OPERATE ON SEPARATE

CIRCUITS.

INSTALLATION:

1. ALL EQUIPMENT SHALL BE INSTALLED TIGHT TO THE BUILDING STRUCTURE AND

SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO THE BUILDING STRUCTURE

UNLESS NOTED OTHERWISE.

2. THE CONTRACTOR SHALL NOT APPRECIABLY DEVIATE FROM THE APPROVED DESIGN

WITHOUT WRITTEN APPROVAL FROM THE ENGINEER.

TESTING:

1. UNLESS SPECIFICALLY NOTED OTHERWISE, THE CONTRACTOR SHALL PERFORM ALL

ACCEPTANCE TESTING IN ACCORDANCE WITH THE APPLICABLE DESIGN CRITERIA

AND THE EQUIPMENT MANUFACTURER'S INSTRUCTIONS.

2. UNLESS SPECIFICALLY NOTED OTHERWISE, THE CONTRACTOR SHALL PERFORM

TESTING AND PROVIDE DOCUMENTATION PRIOR TO REQUESTING ENGINEER'S

PRESENCE TO WITNESS TESTING.

FIRE ALARM GENERAL NOTES

FACU

SPD

GROUND FLOOR

NOTES:

1. TO DEDICATED 120VAC BRANCH CIRCUIT

2. EXISTING FIRE ALARM CONTROL PANEL. THE AVAILABLE CAPACITY IS ASSUMED TO BE ADEQUATE FOR

THE PROPOSED NEW WORK, CONTRACTOR IS RESPONSIBLE FOR DETERMINING ACTUAL AVAILABLE

CAPACITY.

3. THIS RISER DIAGRAM IS INTENDED ONLY TO CAPTURE THE SYSTEM DESIGN INTENT, PANEL CONNECTIONS, AND GENERAL CIRCUIT ROUTING REQUIREMENTS. EXACT QUANTITIES AND TYPES OF DEVICES NECESSARY TO ACCOMPLISH THE DESIGN GOALS ARE NOT INDICATED. THE INTENT OF THIS

RISER DIAGRAM IS TO INDICATE THE GENERAL SYSTEM CONFIGURATION AFTER SUCCESSFUL

COMPLETION OF THE PROJECT.

FIRST FLOOR

SS

WF VS

AIM AIMs F s

SS

AOM AOM AOM

FES

A L A

R M

T R

O U

B L E

S U

P E

R V

IS

O

R Y

SECOND FLOOR PENTHOUSE

SECOND FLOOR ROOF

s s

-A

H U

-5 A

-A

H U

-5 B s

-A

H U

-5 C

AOM

AHU

AOM

AHU

AOM

AHU

FACU

F

WF

FIRE ALARM CONTROL UNIT

FIRE ALARM LEGEND

SPD SURGE PROTECTIVE DEVICE

FIRE ALARM PULL STATION

AIM ADDRESSABLE INPUT MODULE

AOM ADDRESSABLE OUTPUT MODULE

WATERFLOW SWITCH

VS VALVE SUPERVISORY SWITCH

s SMOKE DETECTOR - SPOT TYPE

S SPEAKER

SPEAKER STROBE

STROBE - WALL MOUNT

STROBE - CEILING MOUNT

SYMBOL MODIFIERS

C ncd nW

WP

CEILING MOUNTED

CANDELA RATING

WATT TAP

WEATHER PROOF

AHU AIR HANDLING UNIT CONTROLLER

FES KITCHEN HOOD SYSTEM

s SMOKE DETECTOR - DUCT TYPE

4 WATERFLOW/PRESSURE SWITCH X X X X X X 4

5 CONTROL VALVE SUPERVISORY SWITCH X X X X 5

14 ANY OTHER SYSTEM TROUBLE X X X X 14

SUPERVISORY CONDITIONS A B C D E F G H I K L

A B C D E F G H I K L

X PERFORM OPERATION/REPORT DEVICE STATUS

6 SMOKE DETECTOR - DUCT TYPE X X X X 6

7 KITCHEN HOOD SUPPRESSION SYSTEM COMMON SUPERVISORY X X X X 7

SYSTEM OUTPUTS

SYSTEM INPUTS

F A

C U

A N

N U

N C

IA

T

IO

N

A C

T

IV

A T

E C

O M

M O

N A

L A

R M

S

IG

N A

L I

N D

IC

A

T O

R

A C

T

IV

A T

E A

U D

IB

L E

A L A

R M

S

IG

N A

L

A C

T

IV

A T

E C

O M

M O

N S

U P

E R

V

IS

O R

Y S

IG

N

A L I

N D

IC

A

T O

R

A C

T

IV

A T

E A

U D

IB

L E

S U

P E

R V

IS

O

R Y

S

IG

N A

L

A C

T

IV

A T

E C

O M

M O

N T

R O

U B

L E

S

IG

N A

L I

N D

IC

A

T O

R

A C

T

IV

A T

E A

U D

IB

L E

T R

O U

B L E

S

IG

N A

L

D

IS

P L A

Y /P

R

IN

T C

H A

N G

E O

F S

T A

T U

S

N O

T

IF

IC

A

T

IO

N

A C

T

IV

A T

E T

E M

P O

R A

L

A L E

R T

T O

N E

A N

D P

R E

-R E

C O

R D

E D

F

IR

E

E V

A C

U A

T

IO

N M

E S

S A

G E

T H

R O

U G

H O

U T

B U

IL

D

IN

G

A C

T

IV

A T

E S

T R

O B

E S

T H

R O

U G

H O

U T

B U

IL

D

IN

G

T R

A N

S M

IT

S

IG

N

A L T

O S

U P

E R

V

IS

IN

G

S T

A T

IO

N

A U

X

IL

IA

R

Y F

U N

C T

IO

N

S

S H

U T

D O

W N

A S

S O

C

IA

T E

D A

IR

H

A N

D L

IN

G U

N

IT

ALARM CONDITIONS A B C D E F G H I K L

1 MANUAL ALARM PULL STATION X X X X X X 1

2 SMOKE DETECTOR - SPOT TYPE X X X X X X 2

TROUBLE CONDITIONS A B C D E F G H I K L

8 AC POWER FAILURE X X X X 8

9 LOW BATTERY X X X X 9

10 OPEN CIRCUIT X X X X 10

11 GROUND FAULT X X X X 11

12 NOTIFICATION APPLIANCE CIRCUIT SHORT X X X X 12

13 REMOTE POWER SUPPLY COMMON TROUBLE X X X X 13

NOTE: THIS MATRIX PERTAINS TO SCOPE OF WORK AREA. ALL

EXISTING PROGRAMMING FOR BUILDING NOT TO BE MODIFIED

UNLESS REQUIRED BY SOW FOR THIS PROJECT.

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

KS ARCH REG. NO. A-930, EXP. 12/31/2023

KS ENGR REG. NO. E-2586, EXP. 12/31/2023

STRUCTURAL / CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGR

SPUR DESIGN

25219 MADISON AVENUE, SUITE 100

KANSAS CITY, MO 64108

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT HEALTH & SAFETY

1139 OLIVE STREET,

ST. LOUIS, MO 63101

(314) 436-9492

HEALTHCARE PLANNER

INNOVA GROUP

3196 N. SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH ROAD, STE 1415

PANAMA CITY, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:SPUR #: 2016

/1

/2

:2 :5

P

M

FA001

FIRE ALARM GENERAL NOTES, LEGEND,

AND RISER DIAGRAM

SAB

88 OF 190BLS

100% BID SET

CONSTRUCT INFILL OF

BUILDING 26 AND RENOVATE

SPECIALTY CARE CLINICS

12/21/2022

589-704

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

NOT TO SCALE

FIRE ALARM RISER DIAGRAM2

NOT TO SCALE

FACU INPUT/OUTPUT MATRIX1

NO. REVISION DESCRIPTION DATE

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

KEY PLAN

BLDG 26

BLDG 3 BLDG 1

BLDG 2BLDG 19

BLDG 61

BLDG 62

BLDG 29

N

A B C D E F G H J K L M

DINING AREA

VENDOR

DINING AREA

037A

RETAIL STORE

RETAIL

STORAGE

CORRIDOR

KITCHEN

041A

DISH WASH

041A

SERVING LINE

037B

SAFE

038C

VCS CHIEF

OFFICE

038B

VCS OFFICE

038A

COOLER

044A

FREEZER

044B

FOOD STG

FOOD STG

WORKSTATIONS

GUEST

SERVICES

IT ROOM

HAC

ELEC

STORAGE

DENTAL

MECH

045 042

CLEAN

SUPPLY

SOILED

UTILITY

044 043

TRAY

STORAGE

STERILE

INSTRUMENTS

041 038

MOBILE

EQUIPMENT

MED

040 039

PAT TLT

X-RAY

STF TLT

WAITING

034A

CHECK-IN

KIOSK

034A 034B

WC ALC.

034B

C3

CORRIDOR

C3 035A

RECEPTION

035A

035F

COPY /

SUPPLY

035F

035B

CHIEF

035B

WORKSTATIONS

DTR-8

059058

DTR-7

058057

DTR-6

057056

DTR-5

056055

DTR-4

055054

DTR-3

054053

DTR-2

053052

DTR-1

LAB

A008

CAD/CAM

CART

A008 A007

EQUIP

A007 A006

LIFT

A006 A005

EQUIP

A005 A004

WC

A004 A003

EQUIP

A003 A002

EQUIP

A002 A001

CRASH

CART

A001

035D

LOUNGE

035D

035E

DRESSING

035E

035C

LOCKER

035C

SECURITY

REQUIRED AUDIBILITY LEGEND

54dB AMBIENT SPL 69dB EXPECTED SPL

60dB AMBIENT SPL 75dB EXPECTED SPL

30dB AMBIENT SPL 45dB EXPECTED SPL

(STORAGE OCCUPANCIES)

(BUSINESS OCCUPANCIES)

(ASSEMBLY OCCUPANCIES)

OUT OF SCOPE AREA

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

KS ARCH REG. NO. A-930, EXP. 12/31/2023

KS ENGR REG. NO. E-2586, EXP. 12/31/2023

STRUCTURAL / CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGR

SPUR DESIGN

25219 MADISON AVENUE, SUITE 100

KANSAS CITY, MO 64108

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT HEALTH & SAFETY

1139 OLIVE STREET,

ST. LOUIS, MO 63101

(314) 436-9492

HEALTHCARE PLANNER

INNOVA GROUP

3196 N. SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH ROAD, STE 1415

PANAMA CITY, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:SPUR #: 2016

/1

/2

:2 :0

P

M

FA101

FIRE ALARM AUDIBILITY PLAN -

GROUND FLOOR

SAB

89 OF 190BLS

100% BID SET

CONSTRUCT INFILL OF

BUILDING 26 AND RENOVATE

SPECIALTY CARE CLINICS

12/21/2022

589-704

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

N

1/8" = 1'-0"

FIRE ALARM AUDIBILITY PLAN - GROUND FLOOR1

NO. REVISION DESCRIPTION DATE

The information on this document is preliminary or incomplete, not for

BLDG 3 BLDG 1

BLDG 2BLDG 19

BLDG 61

BLDG 62

BLDG 29

N

A B C D E F G H J K L M

LOUNGE /

LOCKER

GI EXAM

GI EXAM

110 108

GI /

RHEUM

108 106

GI /

RHEUM

106 104

NEURO

104 102

NEURO

CORRIDOR

117 115

CORRIDOR

STF TLT

GI /

RHEUM

113 111

GI EXAM

111 107

NEURO

107 105

PAT TLT

CORRIDOR

CLEAN

UTILITY

A100

SCALE

A100

100A

SHARED

WAITING

100A

TEAM

SPACE 1

109 100B

RECEPTION

100B

A101

ALCOVE

A101

A102

CRASH

CART

A102

ELEC

IT ROOM

PROC TLT

123B

MED EQUIP

STORAGE

CORR.

TEAM SPACE

122A VESTIBULE

122B

PAT. TLT

CPAP STG

IT ROOM

STAFF TLT

MEDICATION

PROCEDURE

ROOM

123A

PFT

126A

PFT TLT

126A

SOILED UTILITY

HAC

O2, EMPTY

129A

O2, FULL

129B

EXAM SP-16

CLEAN UTILITY

STG

141B STG

143B

EXAM SP-17

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

RECEPTION

100C

REQUIRED AUDIBILITY LEGEND

54dB AMBIENT SPL 69dB EXPECTED SPL

60dB AMBIENT SPL 75dB EXPECTED SPL

30dB AMBIENT SPL 45dB EXPECTED SPL

(STORAGE OCCUPANCIES)

(BUSINESS OCCUPANCIES)

(ASSEMBLY OCCUPANCIES)

OUT OF SCOPE AREA

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

KS ARCH REG. NO. A-930, EXP. 12/31/2023

KS ENGR REG. NO. E-2586, EXP. 12/31/2023

STRUCTURAL / CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGR

SPUR DESIGN

25219 MADISON AVENUE, SUITE 100

KANSAS CITY, MO 64108

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT HEALTH & SAFETY

1139 OLIVE STREET,

ST. LOUIS, MO 63101

(314) 436-9492

HEALTHCARE PLANNER

INNOVA GROUP

3196 N. SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH ROAD, STE 1415

PANAMA CITY, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:SPUR #: 2016

/1

/2

:2 :0

P

M

FA102

FIRE ALARM AUDIBILITY PLAN - FIRST

FLOOR

SAB

90 OF 190BLS

100% BID SET

CONSTRUCT INFILL OF

BUILDING 26 AND RENOVATE

SPECIALTY CARE CLINICS

12/21/2022

589-704

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

N

1/8" = 1'-0"

FIRE ALARM AUDIBILITY PLAN - FIRST FLOOR1

NO. REVISION DESCRIPTION DATE

The information on this document is preliminary or incomplete, not for

0.25W 15cd

0.25W15cd

0.25W 15cd

.2

W c d

.2

W c d

.2

W c d

0.25W 15cd

S

0.25W0.25W 15cd

.2

W c d

0.25W 15cd

0.25W 15cd 0.25W 15cd

.2

W c d

0.25W 30cd

0.5W30cd

0.5W 30cd0.5W 75cd

.5

W c d

S

0.25W

0.5W30cd 0.5W30cd

.5

W c d

.5

W c d

S

.5

W

S

.5

W

.5

W c d

.5

W c d

S

0.25W

.2

W c d

0.25W 15cd

F

S

0.25W

A B C D E F G H J K L M

DINING AREA

VENDOR

DINING AREA

037A

RETAIL STORE

RETAIL

STORAGE

CORRIDOR

KITCHEN

041A

DISH WASH

041A

SERVING LINE

037B

SAFE

038C

VCS CHIEF

OFFICE

038B

VCS OFFICE

038A

COOLER

044A

FREEZER

044B

FOOD STG

FOOD STG

WORKSTATIONS

HOLDING CELL

034 HOLDING CELL

GUEST

SERVICES

IT ROOM

HAC

ELEC

STORAGE

DENTAL

MECH

045 042

CLEAN

SUPPLY

SOILED

UTILITY

044 043

TRAY

STORAGE

STERILE

INSTRUMENTS

041 038

MOBILE

EQUIPMENT

MED

040 039

PAT TLT

X-RAY

STF TLT

WAITING

034A

CHECK-IN

KIOSK

034A

C3

CORRIDOR

C3

035A

RECEPTION

035A

035F

COPY /

SUPPLY

035F

035B

CHIEF

035B

WORKSTATIONS

DTR-8

059058

DTR-7

058057

DTR-6

057056

DTR-5

056055

DTR-4

055054

DTR-3

054053

DTR-2

053052

DTR-1

052051

LAB

A008

CAD/CAM

CART

A008 A007

EQUIP

A007 A006

LIFT

A006 A005

EQUIP

A005 A004

WC

A004 A003

EQUIP

A003 A002

EQUIP

A002 A001

CRASH

CART

A001

035D

LOUNGE

035D

035E

DRESSING

035E

035C

LOCKER

035C

VS

WF

VS

WF

FES

AOM

AOM

AOM ALARM

SUPERVISORY

TROUBLE

KEY PLAN

BLDG 26

BLDG 3 BLDG 1

BLDG 2BLDG 19

BLDG 61

BLDG 62

BLDG 29

N th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

KS ARCH REG. NO. A-930, EXP. 12/31/2023

KS ENGR REG. NO. E-2586, EXP. 12/31/2023

STRUCTURAL / CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGR

SPUR DESIGN

25219 MADISON AVENUE, SUITE 100

KANSAS CITY, MO 64108

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT HEALTH & SAFETY

1139 OLIVE STREET,

ST. LOUIS, MO 63101

(314) 436-9492

HEALTHCARE PLANNER

INNOVA GROUP

3196 N. SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH ROAD, STE 1415

PANAMA CITY, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:SPUR #: 2016

/1

/2

:2 :0

P

M

FA103

FIRE ALARM PLAN - GROUND FLOOR

SAB

91 OF 190BLS

100% BID SET

CONSTRUCT INFILL OF

BUILDING 26 AND RENOVATE

SPECIALTY CARE CLINICS

12/21/2022

589-704

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

N

1/8" = 1'-0"

FIRE ALARM PLAN - GROUND FLOOR1

NO. REVISION DESCRIPTION DATE

The information on this document is preliminary or incomplete, not for

0.25W15cd

.2

W c d

0.25W15cd

S

0.25W

.2

W c d

S

.2

W

.2

W c d

0.25W 15cd 0.25W 15cd

S

0.25W

.2

W c d

0.25W 15cd

0.5W 75cd 0.5W 75cd

.5

W c d

.5

W c d

0.25W15cd

.5

W c d

.5

W c d

0.5W75cd

0.25W15cd

0.25W 15cd

S

0.25W

S

0.25W

0.5W 15cd

A B C D E F G H J K L M

ELEC

IT ROOM

PROC TLT

123B

MED EQUIP

STORAGE

CORR.

TEAM SPACE

122A VESTIBULE

122B

PAT. TLT

CPAP STG

IT ROOM

STAFF TLT

MEDICATION

PROCEDURE

ROOM

123A

PFT

126A

PFT TLT

126A

SOILED UTILITY

HAC

O2, EMPTY

129A

O2, FULL

129B

EXAM SP-16

CLEAN UTILITY

STG

141B STG

143B

EXAM SP-17

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

LOUNGE /

LOCKER

116 112

GI EXAM

112 110

GI EXAM

110 108

GI /

RHEUM

108 106

GI /

RHEUM

106 104

NEURO

104 102

NEURO

CORRIDOR

CORRIDOR

STF TLT

GI /

RHEUM

113 111

GI EXAM

111 107

NEURO

107 105

PAT TLT

CORRIDOR

CLEAN

UTILITY

A100

SCALE

A100

100A

SHARED

WAITING

100A

TEAM

SPACE 1

100B

RECEPTION

100B

STAIR

A101

ALCOVE

A101

A102

CRASH

CART

A102 RECEPTION

100C

KEY PLAN

BLDG 26

BLDG 3 BLDG 1

BLDG 2BLDG 19

BLDG 61

BLDG 62

BLDG 29

N th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

KS ARCH REG. NO. A-930, EXP. 12/31/2023

KS ENGR REG. NO. E-2586, EXP. 12/31/2023

STRUCTURAL / CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGR

SPUR DESIGN

25219 MADISON AVENUE, SUITE 100

KANSAS CITY, MO 64108

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT HEALTH & SAFETY

1139 OLIVE STREET,

ST. LOUIS, MO 63101

(314) 436-9492

HEALTHCARE PLANNER

INNOVA GROUP

3196 N. SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH ROAD, STE 1415

PANAMA CITY, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:SPUR #: 2016

/1

/2

:2 :0

P

M

FA104

FIRE ALARM PLAN - FIRST FLOOR

SAB

92 OF 190BLS

100% BID SET

CONSTRUCT INFILL OF

BUILDING 26 AND RENOVATE

SPECIALTY CARE CLINICS

12/21/2022

589-704

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

N

1/8" = 1'-0"

FIRE ALARM PLAN - FIRST FLOOR1

NO. REVISION DESCRIPTION DATE

The information on this document is preliminary or incomplete, not for

1. THE DESIGN AND INSTALLATION OF THE FIRE PROTECTION, FIRE

SUPPRESSION SYSTEM MUST BE IN ACCORDANCE WITH U.S.

DEPARTMENT OF VETERANS AFFAIRS FIRE PROTECTION DESIGN

MANUAL, EIGHTH EDITION, JUNE 2021; NFPA 13: STANDARD FOR THE

INSTALLATION OF SPRINKLER SYSTEMS, 2022 EDITION; NFPA 14:

STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS,

2019 EDITION.

2. THIS INFORMATION HAS BEEN PREPARED TO PROVIDE GUIDANCE FOR

BIDDING. THE CONTRACTOR SHALL BE THE ENGINEER OF RECORD. THE

FIRE PROTECTION CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR

PROVIDING A COMPLETE AND FULLY OPERABLE SYSTEM WHICH SHALL

BE IN STRICT ACCORDANCE WITH PROJECT SPECIFICATIONS AND

APPLICABLE CODES AND STANDARDS. THE WORK THAT IS INDICATED IN

THIS DOCUMENT IS AN OVERVIEW OF THE PROJECT, INTENDED TO

ESTABLISH THE MINIMUM SCOPE REQUIREMENTS FOR THE PROJECT AS

WELL AS THE CONTRACTOR’S RESPONSIBILITIES. THE CONTRACTOR

SHALL SUBMIT A COMPLETE SET OF WORKING DRAWINGS, EQUIPMENT,

AND CALCULATIONS TO THE OWNER’S REPRESENTATIVE AND AHJ FOR

REVIEW AND APPROVAL PRIOR TO FABRICATION AND INSTALLATION

WITH THEIR ENGINEERS SEAL.

3. PRIOR TO BEGINNING ANY CONSTRUCTION, THE CONTRACTOR SHALL BE

RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS, MEASUREMENTS

AND LOCATIONS OF EXISTING FACILITIES, UTILITIES, EQUIPMENT AND

OTHER EXISTING CONDITIONS WHICH MAY AFFECT CONSTRUCTION.

BASE CIVIL ENGINEERING HAS MADE EVERY ATTEMPT TO VERIFY THIS

INFORMATION. HOWEVER, IN THE EVENT OF DISCREPANCIES BETWEEN

THE DRAWINGS AND ACTUAL FIELD CONDITIONS, CONTACT THE

CONTRACTING OFFICER IMMEDIATELY.

4. SPRINKLER CONTRACTOR SHALL COORDINATE LOCATIONS OF FIRE

PROTECTION COMPONENTS INCLUDING PIPING, ALARMS, DRAINS,

SPRINKLERS, TEST POINTS, ETC., WITH ALL ARCHITECTURAL,

STRUCTURAL, MECHANICAL, AND ELECTRICAL COMPONENTS.

OBSTRUCTIONS TO SPRINKLER DISCHARGE SHALL BE CONSIDERED

DURING INSTALLATION. DO NOT INSTALL SPRINKLER PIPING BELOW

EQUIPMENT OR WITHIN CLEARANCE SPACES FOR MECHANICAL AND

ELECTRICAL EQUIPMENT. SPRINKLERS SHALL BE INSTALLED UNDER

OBSTRUCTIONS IN ACCORDANCE WITH NFPA 13.

5. MATERIALS AND ACCESSORIES NECESSARY MUST BE INSTALLED IN

ACCORDANCE WITH THE APPLICABLE NFPA CODES AND STANDARDS,

PROJECT SPECIFICATIONS, AND BE UL LISTED OR FM APPROVED FOR

FIRE PROTECTION USE, UNLESS OTHERWISE NOTED.

6. ALL VALVES INSIDE TO BE PROVIDED WITH ELECTRONIC TAMPER

SWITCHES WIRED TO THE FACU. VALVES IN NORMAL CLOSED POSITION

SHALL BE PROVIDED WITH TAMPER TO ACTIVATE IN THREE TURNS OR

LESS. ALL VALVES OUTSIDE TO BE ELECTRONICALLY MONITORED BY

FIRE ALARM.

7. ALL HANGERS MUST BE PROVIDED AND INSTALLED IN ACCORDANCE

WITH NFPA 13 AND PROJECT SPECIFICATIONS.

8. LOCATION AND INSTALLATION OF PIPE SUPPORTS (HANGERS, VERTICAL

RESTRAINTS, AND GUIDES) SHALL MEET THE REQUIREMENTS OF NFPA 13

AND THE SPECIAL LISTING REQUIREMENTS (IF APPLICABLE) OF THE PIPE

AND SUPPORTS.

9. THE INSPECTOR'S TEST VALVES MUST BE LOCATED NO MORE THAN 7

FEET AFF.

10. APPLICABLE UL CONSTRUCTION DETAILS AND SYSTEMS SHALL BE USED

WHERE FIRE RATED BARRIERS ARE PENETRATED BY SPRINKLER PIPING.

11. ALL VALVES (DRAINS, INSPECTOR'S TEST, CONTROL) MUST BE

IDENTIFIED AS REQUIRED BY NFPA 13.

12. PIPING MUST BE ARRANGED FOR FLUSHING. READILY REMOVABLE

FITTINGS MUST BE PROVIDED AT THE END OF ALL CROSS MAINS.

13. ALL PENDENT SPRINKLERS MUST BE INSTALLED IN THE CENTER OF THE

CEILING TILES.

14. DRAINS MUST BE LOCATED TO PROVIDE DRAINAGE IN ACCORDANCE

WITH NFPA 13. ALL DRAINS AND TEST CONNECTIONS MUST DISCHARGE

TO THE EXTERIOR OF THE BUILDING ON TO A SPLASH BLOCK OR

PAVEMENT, AND SHALL NOT DISCHARGE ACROSS PATHS OF EGRESS.

15. ALL SPRINKLER SYSTEM ALARM INITIATING AND SUPERVISORY DEVICES

MUST BE CONNECTED TO THE FIRE ALARM SYSTEM.

16. ADDITIONAL SPRINKLERS MAY BE REQUIRED UNDER DUCT WORK TO

PROVIDE ADEQUATE COVERAGE PER NFPA 13.

17. A LISTED RELIEF VALVE MUST BE PROVIDED IN ACCORDANCE WITH NFPA

13, SECTION 8.1.2 FOR THE SPRINKLER SYSTEM.

18. THIS BUILDING WILL HAVE A WET PIPE AUTOMATIC SPRINKLER SYSTEM

WHICH WILL REQUIRE ALL AREAS OF THE BUILDING TO BE MAINTAINED

ABOVE 40 DEGREES F.

19. PROVIDE SPRINKLER PROTECTION WITHIN ALL COMBUSTIBLE

CONCEALED SPACES.

20. INSTALL NEW CHECK VALVES, WATERFLOW SWITCHES, AND

INSPECTOR'S TEST CONNECTIONS WITH PRESSURE RELIEF VALVE.

FIRE SUPPRESSION GENERAL NOTES

TO PLAN

SOUTH FIRE

RISER

TO PLAN

NORTH FIRE

RISER

EXISITNG

UNDERGROUND

LEAD-IN

NEW ABOVE

GROUND FIRE

WATER SUPPLY

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

KS ARCH REG. NO. A-930, EXP. 12/31/2023

KS ENGR REG. NO. E-2586, EXP. 12/31/2023

STRUCTURAL / CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGR

SPUR DESIGN

25219 MADISON AVENUE, SUITE 100

KANSAS CITY, MO 64108

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT HEALTH & SAFETY

1139 OLIVE STREET,

ST. LOUIS, MO 63101

(314) 436-9492

HEALTHCARE PLANNER

INNOVA GROUP

3196 N. SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH ROAD, STE 1415

PANAMA CITY, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:SPUR #: 2016

/1

/2

:2 :0

P

M

FX001

FIRE SUPPRESSION GENERAL NOTES

SAB

93 OF 190BLS

100% BID SET

CONSTRUCT INFILL OF

BUILDING 26 AND RENOVATE

SPECIALTY CARE CLINICS

12/21/2022

589-704

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

SCALE: NONE1

FIRE RISER ONE-LINE DIAGRAM

NO. REVISION DESCRIPTION DATE

The information on this document is preliminary or incomplete, not for

BLDG 3 BLDG 1

BLDG 2BLDG 19

BLDG 61

BLDG 62

BLDG 29

N

A B C D E F G H J K L M

DINING AREA

VENDOR

DINING AREA

037A

RETAIL STORE

RETAIL

STORAGE

CORRIDOR

KITCHEN

041A

DISH WASH

041A

SERVING LINE

037B

SAFE

038C

VCS CHIEF

OFFICE

038B

VCS OFFICE

038A

COOLER

044A

FREEZER

044B

FOOD STG

FOOD STG

WORKSTATIONS

GUEST

SERVICES

IT ROOM

HAC

ELEC

STORAGE

DENTAL

MECH

045 042

CLEAN

SUPPLY

SOILED

UTILITY

044 043

TRAY

STORAGE

STERILE

INSTRUMENTS

041 038

MOBILE

EQUIPMENT

MED

040 039

PAT TLT

X-RAY

STF TLT

WAITING

034A

CHECK-IN

KIOSK

034A 034B

WC ALC.

034B

C3

CORRIDOR

C3 035A

RECEPTION

035A

035F

COPY /

SUPPLY

035F

035B

CHIEF

035B

WORKSTATIONS

DTR-8

059058

DTR-7

058057

DTR-6

057056

DTR-5

056055

DTR-4

055054

DTR-3

054053

DTR-2

053052

DTR-1

LAB

A008

CAD/CAM

CART

A008 A007

EQUIP

A007 A006

LIFT

A006 A005

EQUIP

A005 A004

WC

A004 A003

EQUIP

A003 A002

EQUIP

A002 A001

CRASH

CART

A001

035D

LOUNGE

035D

035E

DRESSING

035E

035C

LOCKER

035C

SECURITY

HAZARD CLASSIFICATION LEGEND

LIGHT HAZARD

(0.10 GPM/FT² OVER 1,500 FT² WITH

250 GPM EXTERIOR HOSE DEMAND)

OUT OF SCOPE

EXISTING FIRE SUPPRESSION RISER

PIPING CONTINUATION

EXISTING FIRE SUPPRESSION PIPING

NEW FIRE SUPPRESSION PIPING

ORDINARY HAZARD I

(0.15 GPM/FT² OVER 1,500 FT² WITH

250 GPM EXTERIOR HOSE DEMAND)

ORDINARY HAZARD II

(0.20 GPM/FT² OVER 1,500 FT² WITH

250 GPM EXTERIOR HOSE DEMAND)

FIRE SUPPRESSION SYSTEM BOUNDARY

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

KS ARCH REG. NO. A-930, EXP. 12/31/2023

KS ENGR REG. NO. E-2586, EXP. 12/31/2023

STRUCTURAL / CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGR

SPUR DESIGN

25219 MADISON AVENUE, SUITE 100

KANSAS CITY, MO 64108

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT HEALTH & SAFETY

1139 OLIVE STREET,

ST. LOUIS, MO 63101

(314) 436-9492

HEALTHCARE PLANNER

INNOVA GROUP

3196 N. SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH ROAD, STE 1415

PANAMA CITY, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:SPUR #: 2016

/1

/2

:2 :1

P

M

FX101

FIRE SUPPRESSION HAZARD

CLASSIFICATION PLAN - GROUND

FLOOR

SAB

94 OF 190BLS

100% BID SET

CONSTRUCT INFILL OF

BUILDING 26 AND RENOVATE

SPECIALTY CARE CLINICS

12/21/2022

589-704

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

N

1/8" = 1'-0"

FIRE SUPPRESSION HAZARD CLASSIFICATION PLAN -

GROUND FLOOR1

SHEET KEYNOTES

MARK KEYNOTE

01 WHERE FEASABLE, THE IT ROOM SHALL HAVE 18"

CLEARANCE ABOVE EQUIPMENT TO SPRINKLER

PIPING IN ACCORDANCE WITH APPLICABLE CODES

AND STANDARDS. WHERE EXISTING

CONSTRUCTION ROOM HEIGHT LIMITATIONS

OCCUR, 18" CLEARANCE MAY NOT BE ACHIEVABLE.

IN ADDITION, BUILT-IN TROUGHS AND/OR LEAK

DETECTION IN ACCORDANCE WITH NFPA 70 SHALL

BE PROVIDED TO PROTECT IT EQUIPMENT FROM

ANY WET-PIPE SPRINKLER LEAKAGE.

02 CONTRACTOR TO DEMOLISH EXISTING FIRE RISER.

REBUILD NEW FIRE RISER TO BE FED FROM ABOVE

GROUND MAIN FROM PLAN SOUTH SIDE OF

BUILDING AND SERVE THE PLAN NORTH (EAST)

SIDE OF THE BUIDLING. NEW ABOVEGROUND

PIPING MUST BE CONNECTED TO FIRE SPRINKLER

RISER PRIOR TO DISCONNECTION OF EXISTING

UNDERGROUND PIPING. CONTRACTOR TO

COORDINATE WITH VA PERSONNEL IN REGARDS TO

FIRE SPRNIKLER IMPAIRMENT DURING

CONSTRUCTION. CONTRACTOR TO FIELD VERIFY

EXACT LOCATIONS OF NEW PIPING AND TIE-INS

PRIOR TO ANY CONSTRUCTION.

03 CONTRACTOR TO CONNECT TO EXISTING FIRE

SPRINKLER PIPING. CONTRACTOR TO FIELD VERIFY

EXACT LOCATION PRIOR TO ANY WORK.

04 EXISTING FIRE SPRINKLER RISER IS CURRENTLY

BEING FED FROM UNDERGROUND PIPING. PER

REQUEST FROM THE VA, CONTRACTOR TO

REPLACE ALL EXISITING FIRE SUPPRESSION

VALVES IN GROUND FLOOR PLAN SOUTH STAIR.

CONTRACTOR TO COORDINATE WITH VA

PERSONNEL IN REGARDS TO FIRE SPRINKLER

IMPAIRMENT DURING CONSTRUCTION.

CONTRACTOR TO FIELD VERIFY EXACT LOCATIONS

OF NEW PIPING AND TIE-INS PRIOR TO ANY

CONSTRUCTION.

05 CONTRACTOR TO REMOVE EXISTING HOSE

STATION AND EXISTING FDC PIPING AND

CONNECTION. CONTRACTOR TO FIELD VERIFY

EXACT LOCATION OF FDC, HOSE CONNECTION AND

PIPING PRIOR TO CONSTRUCTION.

06 CONTRACTOR TO PROIVDE SPRINKLER

PROTECTION VIA DRY PENDENT SPINRKLERS IN

FREEZER AND COOLER. CONTRACTOR TO

COORDINATE PENETRATION LOCATIONS WITH

OWNER IN FIELD PRIOR TO CONSTRUCTION.

THIS AREA SUPPLIED

BY PLAN SOUTH

(WEST) FIRE RISER

THIS AREA SUPPLIED

BY PLAN NORTH

(EAST) FIRE RISER

THIS AREA SUPPLIED

BY PLANT SOUTH

(WEST) FIRE RISER

PLAN NORTH (EAST)

FIRE RISER

PLAN SOUTH (WEST)

FIRE RISER

NO. REVISION DESCRIPTION DATE

The information on this document is preliminary or incomplete, not for

BLDG 3 BLDG 1

BLDG 2BLDG 19

BLDG 61

BLDG 62

BLDG 29

N

HAZARD CLASSIFICATION LEGEND

LIGHT HAZARD

(0.10 GPM/FT² OVER 1,500 FT² WITH

250 GPM EXTERIOR HOSE DEMAND)

OUT OF SCOPE

EXISTING FIRE SUPPRESSION RISER

PIPING CONTINUATION

EXISTING FIRE SUPPRESSION PIPING

NEW FIRE SUPPRESSION PIPING

ORDINARY HAZARD I

(0.15 GPM/FT² OVER 1,500 FT² WITH

250 GPM EXTERIOR HOSE DEMAND)

ORDINARY HAZARD II

(0.20 GPM/FT² OVER 1,500 FT² WITH

250 GPM EXTERIOR HOSE DEMAND)

FIRE SUPPRESSION SYSTEM BOUNDARY

A B C D E F G H J K L M

ELEC

IT ROOM

PROC TLT

123B

MED EQUIP

STORAGE

CORR.

TEAM SPACE

122A VESTIBULE

122B

PAT. TLT

CPAP STG

IT ROOM

STAFF TLT

MEDICATION

PROCEDURE

ROOM

123A

PFT

126A

PFT TLT

126A

SOILED UTILITY

HAC

O2, EMPTY

129A

O2, FULL

129B

EXAM SP-16

CLEAN UTILITY

STG

141B STG

143B

EXAM SP-17

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

EXAM SP-16

LOUNGE /

LOCKER

GI EXAM

GI EXAM

110 108

GI /

RHEUM

108 106

GI /

RHEUM

106 104

NEURO

104 102

NEURO

CORRIDOR

CORRIDOR

STF TLT

GI /

RHEUM

113 111

GI EXAM

111 107

NEURO

107 105

PAT TLT

CORRIDOR

CLEAN

UTILITY

A100

SCALE

A100

100A

SHARED

WAITING

100A

TEAM

SPACE 1

109 100B

RECEPTION

100B164

STAIR

A101

ALCOVE

A101

A102

CRASH

CART

A102

RECEPTION

100C th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

KS ARCH REG. NO. A-930, EXP. 12/31/2023

KS ENGR REG. NO. E-2586, EXP. 12/31/2023

STRUCTURAL / CIVIL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGR

SPUR DESIGN

25219 MADISON AVENUE, SUITE 100

KANSAS CITY, MO 64108

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT HEALTH & SAFETY

1139 OLIVE STREET,

ST. LOUIS, MO 63101

(314) 436-9492

HEALTHCARE PLANNER

INNOVA GROUP

3196 N. SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH ROAD, STE 1415

PANAMA CITY, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:SPUR #: 2016

/1

/2

:2 :1

P

M

FX102

FIRE SUPPRESSION HAZARD

CLASSIFICATION PLAN - FIRST FLOOR

SAB

95 OF 190BLS

100% BID SET

CONSTRUCT INFILL OF

BUILDING 26 AND RENOVATE

SPECIALTY CARE CLINICS

12/21/2022

589-704

5500 EAST KELLOGG AVENUE

WICHITA, KANSAS 67218

N

1/8" = 1'-0"

FIRE SUPPRESSION HAZARD CLASSIFICATION PLAN -

FIRST FLOOR1

SHEET KEYNOTES

MARK KEYNOTE

01 WHERE FEASABLE, THE IT ROOM SHALL HAVE 18"

CLEARANCE ABOVE EQUIPMENT TO SPRINKLER PIPING

IN ACCORDANCE WITH APPLICABLE CODES AND

STANDARDS. WHERE EXISTING CONSTRUCTION ROOM

HEIGHT LIMITATIONS OCCUR, 18" CLEARANCE MAY NOT

BE ACHIEVABLE. IN ADDITION, BUILT-IN TROUGHS

AND/OR LEAK DETECTION IN ACCORDANCE WITH NFPA

70 SHALL BE PROVIDED TO PROTECT IT EQUIPMENT

FROM ANY WET-PIPE SPRINKLER LEAKAGE.

GENERAL NOTE: FIRST FLOOR HAS FIRE

SUPPRESSION PIPING WITH ORANGE POLY PIPE.

PER VA DIRECTION, FIRE PROTECTION

CONTRACTOR TO REMOVE POLY PIPE AND

REPLACE WITH HARD PIPE ONLY. CONTRACTOR

TO FIELD VERIFY LOCATION OF EXISTING POLY

PIPING PRIOR TO ANY CONSTRUCTION.

CONTRACTOR TO COORDINATE REMOVAL WITH

VA.

THIS AREA SUPPLIED

BY PLAN SOUTH

(WEST) FIRE RISER

THIS AREA SUPPLIED

BY PLAN NORTH

(EAST) FIRE RISER

PLAN NORTH (EAST)

FIRE RISER

PLAN SOUTH (WEST)

FIRE RISER

NO. REVISION DESCRIPTION DATE

The information on this document is preliminary or incomplete, not for

Sheets
FA001 - FIRE ALARM GENERAL NOTES, LEGEND, AND RISER DIAGRAM
FA101 - FIRE ALARM AUDIBILITY PLAN - GROUND FLOOR
FA102 - FIRE ALARM AUDIBILITY PLAN - FIRST FLOOR
FA103 - FIRE ALARM PLAN - GROUND FLOOR
FA104 - FIRE ALARM PLAN - FIRST FLOOR
FX001 - FIRE SUPPRESSION GENERAL NOTES
FX101 - FIRE SUPPRESSION HAZARD CLASSIFICATION PLAN - GROUND FLOOR
FX102 - FIRE SUPPRESSION HAZARD CLASSIFICATION PLAN - FIRST FLOOR

File details come from the government source that posted it. Updated .