Attachment 5 04_100_ BID SET Architectural Drawings.pdf
PDF 17 MB Posted
- Solicitation number
- 36C77624R0027
About this file
This document includes an architectural drawing file attachment and details of a related federal contract opportunity for construction services. The solicitation number is 36C77624R0027 to construct an infill of Building 26 for dental clinics, a new police office, and renovate for specialty care services at a Veterans Affairs medical center. The contracting agency is the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas. The opportunity type is a solicitation for a construction project to expand and renovate specific areas of an existing VA medical center building.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B C D E F G
2.142.14
2.14
2.14
2.14
2.14
2.14
2.56
2.56
AD113
AD113
AD113
AD113
2.42
2.42
H J
2.42
2.42
2.472.47 2.20 2.20 2.20 2.20
2.26
2.16
2.16
2.20 2.20 2.20 2.20 2.20 2.592.58
2.162.18 2.18 2.16 2.162.18 2.18
2.20
2.20
2.47
2.20
2.47
2.47
2.26 2.26
2.26
2.16 2.16 2.16
OFFICE
E001
11'-3" 7"
2.26
2.50
CONFERENCE
ROOM
E002
CONFERENCE
ROOM
E003
OFFICE
E004
2.16
2.58
6' -1
1/
2" 3'
-4
4"
7' -0
'-1 0"
2.26
2.16
3' -4
3'
-2
2.16
A
'-0
114'-0"
11'-10"
6' -8
2.26
OFFICE IT
SERVER
ROOM
015B 21 '-1
0"
6' -5
7'
-8
6'-5" 3'-8"
3' -8
'-4
25'-2 1/4"5'-9"9'-1"
3' -7
3' -3
8'-6"
3' -4
'-2
2.57
+/- 12'-0"
0'
-0
'-0
+/- 36'-0"
+/- 10'-0"
7'
-0
+/- 10'-0"
6'
-0
0'
-0
+/- 5'-0"
2'-4 1/2" 5'-3 1/2"
1.03
1.03 1.03
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS OTHERWISE NOTED
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE
UTILIZING HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT TO AREA HAS BEEN
INSPECTED BY THE SAVAHCS SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND
THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE
CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN
EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND
MAINTAIN FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR
DUE TO EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO
BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE
MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO
ROOMS OUTSIDE OF SCOPE WITH OWNER
9. REFER TO ENVIRONMENTAL REMEDIATION SHEETS FOR ADDITIONAL INFORMATION REGARDING
HAZARDOUS MATERIAL TREATMENT AND REMOVAL.
GENERAL DEMOLITION NOTES
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF PROJECT
SCOPE SHOWN. REFERENCE GI011 - PHASING PLANS FOR MORE INFORMATION.
KEY PLAN - GROUND FLOOR & FIRST FLOOR
BLDG 26BLDG 61
BLDG 29
BLDG 03PHASE ONE
N
B C D E F G
AD113
AD113
AD113
AD113
H J K L M
2.40
2.16
2.23
2.24 2.26
2.26
2.16 2.26
2.24
2.18 2.16 2.26 2.16
2.16
2.18
2.18
2.16
2.18
2.18
2.20
2.16
2.582.202.20 2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.592.202.202.202.202.202.202.202.202.202.20
25'-2" 6'-3" 2'-3" 9'-6"
COURTYARD
OPEN TO BELOW
2.20NUTRITION /
FOOD
E109
MED ROOM
E108
HSK
E112
2.162.16
2.163' -1
0" 2'
-0
PSA
E103
PSA
E104
PSA
E102
COPIER/FAX
E101
COPIER/FAX
E101
A
8' -1
1/
2"
8' -9
/2
3'-6 1/2"
5' -2
1/ 2"
4'-10"5'-6 1/2"
2.59
INFECTION CONTROL & RISK ASSESSMENT LEGEND
ICRA BARRIER - CONSTRUCTION ENTRANCE & EXIT
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
KS ARCH REG. NO. A-930, EXP. 12/31/2023
KS ENGR REG. NO. E-2586, EXP. 12/31/2023
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGR
SPUR DESIGN
25219 MADISON AVENUE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT HEALTH & SAFETY
1139 OLIVE STREET,
ST. LOUIS, MO 63101
(314) 436-9492
HEALTHCARE PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, STE 1415
PANAMA CITY, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:SPUR #: 2016
/2
/2
:4 :3
A
M
AD111
PHASE ONE - DEMOLITION PLANS
ECO
33 OF 190AJS
100% BID SET
CONSTRUCT INFILL OF
BUILDING 26 AND RENOVATE
SPECIALTY CARE CLINICS
12/21/2022
589-704
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
N
1/8" = 1'-0"
GROUND FLOOR - DEMOLITION FLOOR PLAN - PHASE ONE1
KEYNOTE LEGEND
1.03 ICRA BARRIER.
2.14 DEMOLISH EXISTING CONCRETE PAD IN ITS ENTIRETY.
2.16 DEMOLISH EXISTING WALL CONSTRUCTION TO EXTENT INDICATED.
2.18 DEMOLISH EXISTING FLOORING IN ITS ENTIRETY; CLEAN & PREPARE SUB-FLOOR SURFACE FOR
NEW FLOORING PER RENOVATION PLANS.
2.20 DEMOLISH EXISTING 48"X 69" WINDOW SYSTEM. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
2.23 DEMOLISH EXISTING WATER CLOSET AND ASSOCIATED PLUMBING. REFERENCE PLUMBING
DRAWINGS FOR ADDITIONAL INFORMATION.
2.24 DEMOLISH EXISTING LAVATORY AND ASSOCIATED PLUMBING. REFERENCE PLUMBING DRAWINGS
FOR ADDITIONAL INFORMATION.
2.26 REMOVE AND RETAIN EXISTING DOOR AND FRAME. SALVAGED DOOR AND FRAME TO BE
RETURNED TO VA.
2.40 DEMOLISH EXISTING DRINKING FOUNTAIN.
2.42 REMOVE SOIL WITHIN COURTYARD.
2.47 DEMOLISH EXISTING MECHANICAL LOUVER. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
2.50 DEMOLISH EXISTING RAISED ACCESS FLOORING.
2.56 DEMOLISH EXISTING CONCRETE WALL IN ITS ENTIRETY.
2.57 DEMOLISH EXISTING CONCRETE STAIR AND ASSOCIATED RAILINGS.
2.58 DEMOLISH PORTION OF EXISTING EXTERIOR WALL TO EXTENT INDICATED. REFER TO
STRUCTURAL DRAWINGS FOR SUPPORT STRUCTURE AT EXISTING EXTERIOR WALLS.
2.59 DEMOLISH EXISTING 38"X 69" WINDOW SYSTEM. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
N
1/8" = 1'-0"
LEVEL 1 - DEMOLITION PLAN - PHASE ONE2
NO. REVISION DESCRIPTION DATE
H
2.19
2.29
2.43
2.35
2.37 2.39
2.60
2.34 2.43
2.292.29
2.43 2.29
2.19
CONFERENCE
ROOM
E002
OFFICE
E001
CONFERENCE
ROOM
E003
EXAM ROOM
E004
A
OFFICE IT
SERVER
ROOM
015B
'-8
2.47
2.47
2.20
2.47
2.20
2.20
2.592.202.202.202.20 2.582.202.202.202.202.202.472.47
2.58 7' -0
'-1 0"
'-1
0"
'-8
/2
6' -5
7'
-1 0"
'-2
'-8
4'
-1 0"
9'-9" 19'-0 1/2" 19'-0" 9'-1"
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS OTHERWISE NOTED
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE
UTILIZING HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT TO AREA HAS BEEN
INSPECTED BY THE SAVAHCS SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND
THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE
CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN
EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND
MAINTAIN FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR
DUE TO EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO
BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE
MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO
ROOMS OUTSIDE OF SCOPE WITH OWNER
9. REFER TO ENVIRONMENTAL REMEDIATION SHEETS FOR ADDITIONAL INFORMATION REGARDING
HAZARDOUS MATERIAL TREATMENT AND REMOVAL.
GENERAL DEMOLITION NOTES
KEY PLAN - GROUND FLOOR & FIRST FLOOR
BLDG 26BLDG 61
BLDG 29
BLDG 03PHASE ONE
N
B C D E F G H J
2.192.43
2.43 2.43
2.37
2.35
2.292.34
2.35
2.29
2.19 2.19
2.29
2.19
NUTRITION /
FOOD
E109
MED ROOM
E108
RR
E111
HSK
E112
PSA
E104
PSA
E103
2.29
2.352.37
2.19 2.19
2.29
A
14'-9"
14'-0" 11'-7" 12'-5 1/2" 11'-2 1/2"
9' -5
/2
'-2
/2
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF PROJECT
SCOPE SHOWN. REFERENCE GI011 - PHASING PLANS FOR MORE INFORMATION.
EXISTING EXIT LIGHT
EXISTING CEILING GRID AND TILE TO BE DEMOLISHED
EXISTING LIGHT FIXTURE
TO BE DEMOLISHED
EXISTING RETURN AIR GRILLE
EXISTING SUPPLY AIR DIFFUSER
EXISTING EXHAUST AIR GRILLE
AREA NOT IN CONTRACT
X.XX KEYNOTE; REFERENCE KEYNOTE LEGEND
DEMOLITION CEILING PLAN LEGEND
EXISTING GYPSUM CEILING TO BE DEMOLISHED
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
KS ARCH REG. NO. A-930, EXP. 12/31/2023
KS ENGR REG. NO. E-2586, EXP. 12/31/2023
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGR
SPUR DESIGN
25219 MADISON AVENUE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT HEALTH & SAFETY
1139 OLIVE STREET,
ST. LOUIS, MO 63101
(314) 436-9492
HEALTHCARE PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, STE 1415
PANAMA CITY, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:SPUR #: 2016
/2
/2
:4 :3
A
M
AD112
PHASE ONE - DEMOLITION REFLECTED
CEILING PLANS
ECO
34 OF 190AJS
100% BID SET
CONSTRUCT INFILL OF
BUILDING 26 AND RENOVATE
SPECIALTY CARE CLINICS
12/21/2022
589-704
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
N
1/8" = 1'-0"
GROUND FLOOR - DEMOLITION REFLECTED CEILING PLAN - PHASE ONE1
KEYNOTE LEGEND
2.19 DEMOLISH EXISTING GRID CEILING SYSTEM TO EXTENT INDICATED.
2.20 DEMOLISH EXISTING 48"X 69" WINDOW SYSTEM. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
2.29 DEMOLISH EXISTING 2X4 LIGHT FIXTURE.
2.34 DEMOLISH EXISTING 2X2 SUPPLY.
2.35 DEMOLISH EXISTING 1X1 SUPPLY.
2.37 DEMOLISH EXISTING 1X2 RETURN.
2.39 DEMOLISH EXISTING 2X4 RETURN.
2.43 DEMOLISH EXISTING FIRE SPRINKLER HEAD.
2.47 DEMOLISH EXISTING MECHANICAL LOUVER. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
2.58 DEMOLISH PORTION OF EXISTING EXTERIOR WALL TO EXTENT INDICATED. REFER TO
STRUCTURAL DRAWINGS FOR SUPPORT STRUCTURE AT EXISTING EXTERIOR WALLS.
2.59 DEMOLISH EXISTING 38"X 69" WINDOW SYSTEM. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
2.60 DEMOLISH EXISTING GYPSUM BOARD CEILING TO EXTENT INDICATED.
N
1/8" = 1'-0"
FIRST FLOOR - DEMOLITION REFLECTED CEILING PLAN - PHASE ONE2
GROUND FLOOR
0"
FIRST FLOOR
10'-8"
ROOF 1
35'-6"
SECOND FLOOR
22'-8"
B C D E F G
ROOF 2
47'-6"
BLDG 61 BLDG 26
2.42
A P
P R
O X
3'
-0
H
2.072.072.122.072.072.072.122.072.072.072.12
2.072.202.202.202.072.072.072.072.072.202.20
2.592.202.202.202.072.072.072.072.072.072.07
2.47
2.47 2.58
2.59
2.58
25'-1" 6'-4" 12'-10"9'-6"
2.58
A
31'-5"
5' -9
3'
-2
W / S
T R
U C
T U
R A
L D
W G
S
C O
O R
D
IN
A T
E O
P E
N
IN
G
W / S
T R
U C
T U
R A
L D
W G
S
C O
O R
D
IN
A T
E O
P E
N
IN
G
22'-4"
GROUND FLOOR
0"
FIRST FLOOR
10'-8"
ROOF 1
35'-6"
SECOND FLOOR
22'-8"
BCDEFG
BLDG 26 BLDG 61
2.42
H
2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20
2.20
2.20
2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20
2.072.07
2.47 2.47
2.072.072.072.072.072.202.202.20
2.20
2.16
A
25'-8" 11'-3"
36'-11"
W / S
T R
U C
T . D
W G
S
C O
O R
D
IN
A T
E O
P E
N
IN
G
'-8
GROUND FLOOR
0"
FIRST FLOOR
10'-8"
ROOF 1
35'-6"
SECOND FLOOR
22'-8"
ROOF 2
47'-6"
BLDG 26BLDG 26
2.14
2.42 2.56 2.56
A P
P R
O X
3'
-0
2.14
579 410 68
2.16
14'-10" 7'-0" 23'-2"
2.47
2.26
W / S
T R
U C
T . D
W G
S
C O
O R
D
IN
A T
E O
P E
N
IN
G
'-8
GROUND FLOOR
0"
FIRST FLOOR
10'-8"
ROOF 1
35'-6"
SECOND FLOOR
22'-8"
BLDG 26 BLDG 26
2.20 2.202.20 2.472.47 2.47
2.42
5 7 94 106 8
2.202.202.202.202.202.20
2'-0" 11'-0"
2.47 2.20 2.07 2.12
2.58
2.42
3' -2
5'
-9
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF PROJECT
SCOPE SHOWN. REFERENCE GI011 - PHASING PLANS FOR MORE INFORMATION.
1. ALL DIMENSIONS ARE TO FACE OF EXISTING BRICK VENEER, UNLESS OTHERWISE NOTED.
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. THE CONTRACTOR SHALL REMOVE MASONRY VENEER AS REQUIRED TO PROVIDE NEW
OPENINGS THROUGH EXTERIOR ASSEMBLY. COORDINATE NEW OPENING AND REQUIRED
SUPPORT WITH STRUCTURAL DRAWINGS.
4. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE
CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.
5. REFER TO ENVIRONMENTAL REMEDIATION SHEETS FOR ADDITIONAL INFORMATION REGARDING
HAZARDOUS MATERIAL TREATMENT AND REMOVAL.
GENERAL EXTERIOR ELEVATION DEMOLITION NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
KS ARCH REG. NO. A-930, EXP. 12/31/2023
KS ENGR REG. NO. E-2586, EXP. 12/31/2023
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGR
SPUR DESIGN
25219 MADISON AVENUE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT HEALTH & SAFETY
1139 OLIVE STREET,
ST. LOUIS, MO 63101
(314) 436-9492
HEALTHCARE PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, STE 1415
PANAMA CITY, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:SPUR #: 2016
/2
/2
:4 :4
A
M
AD113
PHASE ONE - DEMOLITION EXTERIOR
ELEVATIONS
ECO
35 OF 190AJS
100% BID SET
CONSTRUCT INFILL OF
BUILDING 26 AND RENOVATE
SPECIALTY CARE CLINICS
12/21/2022
589-704
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
1/8" = 1'-0" 1/ AD111
EAST COURTYARD DEMOLITION ELEVATION - PHASE ONE1
1/8" = 1'-0" 1/ AD111
WEST COURTYARD DEMOLITION ELEVATION - PHASE ONE3
1/8" = 1'-0" 1/ AD111
NORTH COURTYARD DEMOLITION ELEVATION - PHASE ONE2
1/8" = 1'-0" 1/ AD111
SOUTH COURTYARD DEMOLITION ELEVATION - PHASE ONE4
KEYNOTE LEGEND
2.07 EXISTING WINDOW SYSTEM TO REMAIN IN PLACE.
2.12 EXISTING MECHANICAL LOUVER TO REMAIN IN PLACE.
2.14 DEMOLISH EXISTING CONCRETE PAD IN ITS ENTIRETY.
2.16 DEMOLISH EXISTING WALL CONSTRUCTION TO EXTENT INDICATED.
2.20 DEMOLISH EXISTING 48"X 69" WINDOW SYSTEM. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
2.26 REMOVE AND RETAIN EXISTING DOOR AND FRAME. SALVAGED DOOR AND FRAME TO BE
RETURNED TO VA.
2.42 REMOVE SOIL WITHIN COURTYARD.
2.47 DEMOLISH EXISTING MECHANICAL LOUVER. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
2.56 DEMOLISH EXISTING CONCRETE WALL IN ITS ENTIRETY.
2.58 DEMOLISH PORTION OF EXISTING EXTERIOR WALL TO EXTENT INDICATED. REFER TO
STRUCTURAL DRAWINGS FOR SUPPORT STRUCTURE AT EXISTING EXTERIOR WALLS.
2.59 DEMOLISH EXISTING 38"X 69" WINDOW SYSTEM. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
2.26 2.26
2.16
2.16
2.16
2.25
2.162.16
2.26
2.26
2.26
2.26
2.16
2.16
2.262.26
2.16
2.16
2.16
2.28
2.16
2.26 2.16 2.16
2.28
2.16
2.16
2.16
2.21
2.24
2.28
2.28
2.24
2.26
2.28
2.24
2.162.16
2.16 2.16
2.21
2.21
2.16
2.28
2.26
2.28
2.28 2.16
2.16
2.16
H J K L M
2.26
2.16
2.16
2.28
2.592.202.202.202.202.202.472.202.202.202.47
2.49
RETAIL
STORE
E039
CANTEEN
SUPPLIES
E038
STORAGE
E037
FREEZER
E036
HSK
E034
CANTEEN
SERVICE
E033
OFFICE
E042
OFFICE
E042A
CANTEEN
SERVICE
E032
CANTEEN
SERVICE
E031
2.54
A
1.03
1.03
2.26
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS OTHERWISE NOTED
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE
UTILIZING HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT TO AREA HAS BEEN
INSPECTED BY THE SAVAHCS SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND
THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE
CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN
EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND
MAINTAIN FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR
DUE TO EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO
BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE
MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO
ROOMS OUTSIDE OF SCOPE WITH OWNER
9. REFER TO ENVIRONMENTAL REMEDIATION SHEETS FOR ADDITIONAL INFORMATION REGARDING
HAZARDOUS MATERIAL TREATMENT AND REMOVAL.
GENERAL DEMOLITION NOTES
KEY PLAN - GROUND FLOOR AND FIRST FLOOR
BLDG 26
BLDG 61
BLDG 29
BLDG 03
PHASE TWO
N
PHASE THREE
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF PROJECT
SCOPE SHOWN. REFERENCE GI011 - PHASING PLANS FOR MORE INFORMATION.
B C D E F G
HAC
E107
NAME
E110
2.16
2.24
2.26
2.18
2.21
2.24
2.21
2.26
2.18
2.21
2.24
2.21 2.18
2.26
2.16
2.16
2.26
2.16
2.16 2.24
2.26
2.16
2.16
2.26
2.16
2.16
2.21
2.24
2.21
2.26
2.16
2.21
2.24
2.21
2.26
2.16
2.21
2.24
2.21
2.26
2.16
2.21
2.24
2.21
2.26
2.16
2.21
2.24
2.21
2.26
2.16 2.18
2.16 2.18
2.18 2.18
2.18 2.18
2.18
2.21
2.24
2.21
2.26
2.16
2.18
2.18 2.18
2.21
2.24
2.21
2.26
2.16
2.18
2.21
2.24
2.21
2.26
2.16
2.18
2.26
2.21
2.24
2.21
2.26
2.16
2.18
2.21
2.24
2.21
2.26
2.16
2.18
2.21
2.24
2.21
2.26
2.16
2.18
2.21
2.24
2.21
2.26
2.16
2.18
2.21
2.24
2.21
2.26
2.16
2.18
2.21
2.24
2.21
2.26
2.16
2.18
2.16
2.16
2.24 2.26
2.16
2.18 2.262.26
2.03
2.16
2.18
2.16 2.162.18
H J K L M
2.16
2.20
2.26
2.20 2.20 2.20 2.20
6'-3"
EXAM ROOM
E135
EXAM ROOM
E132
EXAM ROOM
E131
COMM
CLOSET
E124
COMM
CLOSET
E117
EXAM ROOM
E130
ACS PRIMARY
CARE
E125
EXAM ROOM
E123
EXAM ROOM
E118
EXAM ROOM
E116
WAITING
ROOM
E113
EXAM ROOM
E115
EXAM ROOM
E114
WAITING
ROOM
E105
EXAM ROOM
E120
EXAM ROOM
E121
EXAM ROOM
E127
OFFICE
E106
HAC
E107
EXAM ROOM
E133
EXAM ROOM
E129
EXAM ROOM
E128
EXAM ROOM
E126
EXAM ROOM
E122
EXAM ROOM
E119
STORAGE
ROOM
E134
1.03 2.26
2.16
A
1.03
2.16
2.16
1.03
1.03
INFECTION CONTROL & RISK ASSESSMENT LEGEND
ICRA BARRIER - CONSTRUCTION ENTRANCE & EXIT
K L M
2.26
2.16
2.26
2.16
2.26
2.18
BREAKROOM
E005 WHEELCHAIR
STORAGE
E005
2.26 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
KS ARCH REG. NO. A-930, EXP. 12/31/2023
KS ENGR REG. NO. E-2586, EXP. 12/31/2023
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGR
SPUR DESIGN
25219 MADISON AVENUE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT HEALTH & SAFETY
1139 OLIVE STREET,
ST. LOUIS, MO 63101
(314) 436-9492
HEALTHCARE PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, STE 1415
PANAMA CITY, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:SPUR #: 2016
/2
/2
:4 :4
A
M
AD121
PHASE TWO & THREE - DEMOLITION
PLANS
ECO
36 OF 190AJS
100% BID SET
CONSTRUCT INFILL OF
BUILDING 26 AND RENOVATE
SPECIALTY CARE CLINICS
12/21/2022
589-704
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
N
1/8" = 1'-0"
GROUND FLOOR - DEMOLITION FLOOR PLAN - PHASE TWO1
KEYNOTE LEGEND
1.03 ICRA BARRIER.
2.03 EXISTING WALL TO REMAIN.
2.16 DEMOLISH EXISTING WALL CONSTRUCTION TO EXTENT INDICATED.
2.18 DEMOLISH EXISTING FLOORING IN ITS ENTIRETY; CLEAN & PREPARE SUB-FLOOR SURFACE FOR
NEW FLOORING PER RENOVATION PLANS.
2.20 DEMOLISH EXISTING 48"X 69" WINDOW SYSTEM. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
2.21 DEMOLISH EXISTING CASEWORK AND/OR COUNTER IN ITS ENTIRETY.
2.24 DEMOLISH EXISTING LAVATORY AND ASSOCIATED PLUMBING. REFERENCE PLUMBING
DRAWINGS FOR ADDITIONAL INFORMATION.
2.25 DEMOLISH EXISTING MOP SINK AND ASSOCIATED PLUBMING. REFERENCE PLUMBING DRAWINGS
FOR ADDITIONAL INFORMATION.
2.26 REMOVE AND RETAIN EXISTING DOOR AND FRAME. SALVAGED DOOR AND FRAME TO BE
RETURNED TO VA.
2.28 REMOVE AND RETAIN EXISTING EQUIPMENT AND SALVAGE FOR REINSTALLATION. EQUIPMENT
TO BE RETURNED TO VA.
2.47 DEMOLISH EXISTING MECHANICAL LOUVER. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
2.49 TEMPORARY CONSTRUCTION BARRIER AND DOOR.
2.54 EXISTING WALK-IN COOLER AND FREEZER TO BE DISASSEMBLED AND SALVAGED FOR
REINSTALLATION. EQUIPMENT TO BE RETURNED TO VA.
2.59 DEMOLISH EXISTING 38"X 69" WINDOW SYSTEM. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
N
1/8" = 1'-0"
FIRST FLOOR - DEMOLITION PLAN - PHASE TWO2
N
1/8" = 1'-0" 1/ AD113
GROUND FLOOR - DEMO PLAN - PHASE THREE3
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS OTHERWISE NOTED
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE
UTILIZING HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT TO AREA HAS BEEN
INSPECTED BY THE SAVAHCS SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND
THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE
CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN
EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND
MAINTAIN FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR
DUE TO EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO
BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE
MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO
ROOMS OUTSIDE OF SCOPE WITH OWNER
9. REFER TO ENVIRONMENTAL REMEDIATION SHEETS FOR ADDITIONAL INFORMATION REGARDING
HAZARDOUS MATERIAL TREATMENT AND REMOVAL.
GENERAL DEMOLITION NOTES
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF PROJECT
SCOPE SHOWN. REFERENCE GI011 - PHASING PLANS FOR MORE INFORMATION.
B C D E F G
OPEN TO
STRUCTURE
OPEN TO
STRUCTURE
WALK-IN
REFRIGERATOR UNIT
WALK-IN
REFRIGERATOR UNIT
H J K L M
2.30
2.43
2.19
2.45 2.29
2.43 2.352.332.36
2.32
2.30
2.34
2.36
2.45
2.43
2.31
2.29 2.43
2.29 2.45
2.43
2.36
2.29
2.45
RETAIL
STORE
E039
CANTEEN
SUPPLIES
E038
STORAGE
E037
HSK
E034
HSK
E034
OFFICE
E042
OFFICE
E042A
CANTEEN
SERVICE
E032
CANTEEN
SERVICE
E032
CANTEEN
SERVICE
E031 A
2.60
KEY PLAN - GROUND FLOOR AND FIRST FLOOR
BLDG 26
BLDG 61
BLDG 29
BLDG 03
PHASE TWO
N
PHASE THREE
B C D E F G H J K L M
2.29
2.35
2.43
2.29
2.35
2.43
2.33
2.29
2.43
2.33
2.43
2.29
2.29
2.29
2.43
2.35
EXAM ROOM
E135
EXAM ROOM
E132
EXAM ROOM
E131
COMM
CLOSET
E124
COMM
CLOSET
E117
EXAM ROOM
E130
ACS PRIMARY
CARE
E125
EXAM ROOM
E123
EXAM ROOM
E118
EXAM ROOM
E116
WAITING
ROOM
E113
EXAM ROOM
E115
EXAM ROOM
E115
EXAM ROOM
E114
EXAM ROOM
E114
WAITING
ROOM
E105
WAITING
ROOM
E105
EXAM ROOM
E120
EXAM ROOM
E120
EXAM ROOM
E121
EXAM ROOM
E121
EXAM ROOM
E127
EXAM ROOM
E127
OFFICE
E106
OFFICE
E106
HAC
E107
EXAM ROOM
E133
EXAM ROOM
E133
EXAM ROOM
E129
EXAM ROOM
E129
EXAM ROOM
E128
EXAM ROOM
E128
EXAM ROOM
E126
EXAM ROOM
E126
EXAM ROOM
E122
EXAM ROOM
E122
EXAM ROOM
E119
EXAM ROOM
E119
STORAGE
ROOM
E134
STORAGE
ROOM
E134
A
K L M
WHEEL CHAIR
STORAGE
E006
BREAKROOM
E005
2.19 2.192.60
2' -6
/2
2.60
2.29
2.34
2.43 2.33 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
KS ARCH REG. NO. A-930, EXP. 12/31/2023
KS ENGR REG. NO. E-2586, EXP. 12/31/2023
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGR
SPUR DESIGN
25219 MADISON AVENUE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT HEALTH & SAFETY
1139 OLIVE STREET,
ST. LOUIS, MO 63101
(314) 436-9492
HEALTHCARE PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, STE 1415
PANAMA CITY, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:SPUR #: 2016
/2
/2
:4 :5
A
M
AD122
PHASE TWO & THREE- DEMOLITION
REFLECTED CEILING PLANS
ECO
37 OF 190AJS
100% BID SET
CONSTRUCT INFILL OF
BUILDING 26 AND RENOVATE
SPECIALTY CARE CLINICS
12/21/2022
589-704
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
KEYNOTE LEGEND
2.19 DEMOLISH EXISTING GRID CEILING SYSTEM TO EXTENT INDICATED.
2.29 DEMOLISH EXISTING 2X4 LIGHT FIXTURE.
2.30 DEMOLISH EXISTING 2X2 LIGHT FIXTURE.
2.31 DEMOLISH EXISTING 1X4 LIGHT FIXTURE.
2.32 DEMOLISH EXISTING PENDANT LIGHT FIXTURE.
2.33 DEMOLISH EXISTING 1X2 SUPPLY.
2.34 DEMOLISH EXISTING 2X2 SUPPLY.
2.35 DEMOLISH EXISTING 1X1 SUPPLY.
2.36 DEMOLISH EXISTING 2X2 RETURN.
2.43 DEMOLISH EXISTING FIRE SPRINKLER HEAD.
2.45 DEMOLISH EXISTING SECURITY CAMERA.
2.60 DEMOLISH EXISTING GYPSUM BOARD CEILING TO EXTENT INDICATED.
N
1/8" = 1'-0"
GROUND FLOOR - DEMOLITION REFLECTED CEILING PLAN - PHASE TWO1
N
1/8" = 1'-0"
FIRST FLOOR - DEMOLITION REFLECTED CEILING PLAN - PHASE TWO2
N
1/8" = 1'-0" 1/ AD113
GROUND FLOOR - DEMO RCP - PHASE THREE3
GROUND FLOOR
0"
FIRST FLOOR
10'-8"
ROOF 1
35'-6"
SECOND FLOOR
22'-8"
B C D E F G
ROOF 2
47'-6"
BLDG 61 BLDG 26
H
2.07 2.07 2.07 2.07 2.07 2.07 2.07
2.20 2.20 2.20 2.20 2.20
44'-1"12'-3"6'-3"
2.16
2.47 2.472.47 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.59
A
62'-7"
'-4
W / S
T R
U C
T U
R A
L D
W G
S
C O
O R
D
IN
A T
E O
P E
N
IN
G
W / S
T R
U C
T U
R A
L D
W G
S
C O
O R
D
IN
A T
E O
P E
N
IN
G
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF PROJECT
SCOPE SHOWN. REFERENCE GI011 - PHASING PLANS FOR MORE INFORMATION.
1. ALL DIMENSIONS ARE TO FACE OF EXISTING BRICK VENEER, UNLESS OTHERWISE NOTED.
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. THE CONTRACTOR SHALL REMOVE MASONRY VENEER AS REQUIRED TO PROVIDE NEW
OPENINGS THROUGH EXTERIOR ASSEMBLY. COORDINATE NEW OPENING AND REQUIRED
SUPPORT WITH STRUCTURAL DRAWINGS.
4. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE
CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.
5. REFER TO ENVIRONMENTAL REMEDIATION SHEETS FOR ADDITIONAL INFORMATION REGARDING
HAZARDOUS MATERIAL TREATMENT AND REMOVAL.
GENERAL EXTERIOR ELEVATION DEMOLITION NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
KS ARCH REG. NO. A-930, EXP. 12/31/2023
KS ENGR REG. NO. E-2586, EXP. 12/31/2023
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGR
SPUR DESIGN
25219 MADISON AVENUE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT HEALTH & SAFETY
1139 OLIVE STREET,
ST. LOUIS, MO 63101
(314) 436-9492
HEALTHCARE PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, STE 1415
PANAMA CITY, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:SPUR #: 2016
/2
/2
:4 :5
A
M
AD123
PHASE TWO - DEMOLITION EXTERIOR
ELEVATIONS
ECO
38 OF 190AJS
100% BID SET
CONSTRUCT INFILL OF
BUILDING 26 AND RENOVATE
SPECIALTY CARE CLINICS
12/21/2022
589-704
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
KEYNOTE LEGEND
2.07 EXISTING WINDOW SYSTEM TO REMAIN IN PLACE.
2.16 DEMOLISH EXISTING WALL CONSTRUCTION TO EXTENT INDICATED.
2.20 DEMOLISH EXISTING 48"X 69" WINDOW SYSTEM. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
2.47 DEMOLISH EXISTING MECHANICAL LOUVER. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
2.59 DEMOLISH EXISTING 38"X 69" WINDOW SYSTEM. REFER TO HAZARDOUS MATERIALS SHEETS
REGARDING REMOVAL OF HAZARDOUS MATERIALS.
1/8" = 1'-0" 1/ AE409
EAST COURTYARD DEMOLITION ELEVATION - PHASE TWO1
BASE
PLAN
HEAD
METAL STUD U-TRACK (TOP AND BOTTOM)
LINE OF CEILING
(REF: RCP FOR HEIGHT & TYPE)
WALL FINISH
(REF: ROOM FINISH SCHEDULE)
WIDTH
ACTUAL
5/8"
WIDTH
STUD 5/8"
BASE
PLAN
HEAD
LINE OF CEILING
(REF: RCP FOR HEIGHT & TYPE)
WALL FINISH
(REF: ROOM FINISH SCHEDULE)
5/8" GYPSUM BOARD EACH SIDE
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE - (REF: ROOM FINISH SCHEDULE)
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE (REF: ROOM FINISH SCHEDULE)
BATT INSULATION WHERE
SPECIFIED IN SCHEDULE
BASE
PLAN
HEAD
UNDERSIDE OF STRUCTURE
WALL FINISH
(REF: ROOM FINISH SCHEDULE)
WIDTH
ACTUAL
1"TYPE X
FIN FLOOR- (REF: ROOM FINISH SCHEDULE)
BASE - (REF: ROOM FINISH SCHEDULE)
ROOM SIDE SHAFT SIDE
BASE
PLAN
HEAD
UNDERSIDE OF STRUCTURE
LINE OF CEILING (REF: RCP FOR HEIGHT & TYPE)
WALL FINISH (REF: ROOM FINISH SCHEDULE)
WIDTH
ACTUAL
5/8"
WIDTH
STUD VARIES
WIDTH
STUD 5/8"
5/8" GYPSUM BOARD EACH SIDE
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE - (REF: ROOM FINISH SCHEDULE)
METAL STUD PER SCHEDULE
BATT INSULATION WHERE
SPECIFIED IN SCHEDULE
FIRE RATED SEALANT AROUND PERIMETER
FIRE RATED SEALANT AROUND PERIMETER
ACOUSTICAL SEALANT AROUND
PERIMETER (INSULATED WALLS)
ACOUSTICAL SEALANT AROUND
PERIMETER (INSULATED WALLS)
ACOUSTICAL SEALANT AROUND
PERIMETER (INSULATED WALLS)
WIDTH
STUD5/8"
WIDTH
ACTUAL
BATT INSULATION WHERE
SPECIFIED IN SCHEDULE
DIM DIMDIM DIMDIM DIM
DIM DIM
A3
BASIC PARTITION
ASSEMBLY CATEGORY
FRAMING UNIT
SIZE CATEGORY
BASE
PLAN
HEAD
DIM DIM
WIDTH
ACTUAL
5/8"
WIDTH
STUD 5/8"
PARTITION TAG
5/8"TYPE X
WIDTH
STUD
CH STUD PER SCHEDULE
METAL STUD PER SCHEDULE METAL STUD PER SCHEDULE
5/8" GYPSUM BOARD
METAL STUD U-TRACK (TOP AND BOTTOM)
METAL STUD U-TRACK (TOP AND BOTTOM)
1" GYPSUM SHAFT LINER
UNDERSIDE OF STRUCTURE
LINE OF CEILING (REF: RCP FOR HEIGHT & TYPE)
WALL FINISH (REF: ROOM FINISH SCHEDULE)
5/8" GYPSUM BOARD EACH SIDE
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE (REF: ROOM FINISH SCHEDULE)
METAL STUD PER SCHEDULE
FIRE-RATED SEALANT AROUND PERIMETER
METAL STUD U-TRACK (TOP AND BOTTOM)
PARTITION
PER PLAN
TYPICAL PARTITION TAG
BASE
PLAN
HEAD
METAL STUD U-TRACK (TOP AND BOTTOM)
LINE OF CEILING
(REF: RCP FOR HEIGHT & TYPE)
WALL FINISH (REF: ROOM FINISH SCHEDULE)
WIDTH
ACTUAL
5/8"
WIDTH
STUD 5/8"
5/8" GYPSUM BOARD EACH SIDE
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE - (REF: ROOM FINISH SCHEDULE)
BATT INSULATION
ACOUSTICAL SEALANT AROUND
PERIMETER (INSULATED WALLS)
DIM DIM
HEAVY GAUGE METAL STUD PER SCHEDULE
RESILIENT CHANNEL
BASE
PLAN
HEAD
METAL STUD U-TRACK (TOP AND BOTTOM)
LINE OF CEILING
(REF: RCP FOR HEIGHT & TYPE)
WALL FINISH
(REF: ROOM FINISH SCHEDULE)
WIDTH
ACTUAL
5/8"
WIDTH
STUD 5/8"
5/8" GYPSUM BOARD EACH SIDE
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE - (REF: ROOM FINISH SCHEDULE)
BATT INSULATION WHERE
SPECIFIED IN SCHEDULE
ACOUSTICAL SEALANT AROUND
PERIMETER (INSULATED WALLS)
DIM DIM
METAL STUD PER SCHEDULE
LEAD LINING
ADJACENT
ROOM SIDE
EXAM SIDE
BASE
PLAN
HEAD
METAL STUD U-TRACK (TOP AND BOTTOM)
LINE OF CEILING
(REF: RCP FOR HEIGHT & TYPE)
WALL FINISH
(REF: ROOM FINISH SCHEDULE)
WIDTH
ACTUAL
5/8"
WIDTH
STUD 5/8"
5/8" GYPSUM BOARD EACH SIDE
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE - (REF: ROOM FINISH SCHEDULE)
BATT INSULATION WHERE
SPECIFIED IN SCHEDULE
ACOUSTICAL SEALANT AROUND
PERIMETER (INSULATED WALLS)
DIM DIM
METAL STUD PER SCHEDULE
A B
O V
E C
E
IL
IN
G
E X
T E
N D
BATT INSULATION WHERE
SPECIFIED IN SCHEDULE BELOW
BASE
PLAN
HEAD
WIDTH
ACTUAL
5/8"
WIDTH
STUD 5/8"
CMU BLOCK TO MATCH ADJACENT EXISTING CONSTRUCTION
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE TO MATCH EXISTING
DIM DIM
BASE - (REF: ROOM FINISH SCHEDULE)
EXISTING CORRIDOR RENOVATED SPACE
FIBER-REINFORCED PLASTIC (FRP) PANEL
HOLDING CELL SIDE
OMIT GYPSUM BOARD AND FRP AGAINST EXISTING WALL CONDITIONS
BASE
PLAN
HEAD
DIM DIM
WIDTH
ACTUAL
5/8"
WIDTH
STUD 5/8"
UNDERSIDE OF STRUCTURE
LINE OF CEILING (REF: RCP FOR HEIGHT & TYPE)
WALL FINISH (REF: ROOM FINISH SCHEDULE)
5/8" GYPSUM BOARD EACH SIDE
FIN FLOOR (REF: ROOM FINISH SCHEDULE)
BASE (REF: ROOM FINISH SCHEDULE)
METAL STUD PER SCHEDULE
FIRE-RATED SEALANT AROUND PERIMETER
METAL STUD U-TRACK (TOP AND BOTTOM)
FORCE-RESISTANT WIRE MESH
1. REFER TO PLANS FOR LOCATION AND TYPES OF EACH PARTITION.
2. PAINT CONTINUOUS 4" TALL, STENCILED LETTERS, ABOVE CEILING, ON BOTH SIDES OF ALL FIRE AND SMOKE WALLS DESIGNATING THE PARTITION RATING INDICATED ON THE LIFE SAFETY PLAN.
3. REFER TO FINISH SCHEDULE AND INTERIOR ELEVATIONS FOR LOCATIONS OF ALL WALL TILE.
PROVIDE AND INSTALL CEMENTITIOUS BACKER BOARD IN LIEU OF GYPSUM BOARD AT ALL
SCHEDULED TILE LOCATIONS. UNLESS NOTED OTHERWISE, TILE SHALL BE INSTALLED PER TILE COUNCIL OF AMERICA LATEST STANDARDS FOR EACH TYPE OF BACKING MATERIAL REPRESENTED
IN WALL/PARTITION.
4. ALL SUSPENDED WALLS AND PARTITIONS SHALL HAVE GYPSUM BOARD WHICH EXTENDS A
MINIMUM OF 6" ABOVE THE SUSPENDED CEILING UNLESS SHOWN AND/OR NOTED OTHERWISE BY
THE ARCHITECT.
5. REFER TO STRUCTURAL DRAWINGS FOR ALL LOAD BEARING WALL CONDITIONS IN REGARDS TO
STRUCTURAL REQUIREMENTS.
6. "ALIGN" MEANS SIMILAR COMPONENTS OF CONSTRUCTION, E.G. WALLS, JAMBS, ETC. SHALL ALIGN
ACROSS VOIDS AND JOINTS.
7. PARTITIONS SHALL BE CONTINUOUS OVER DOORS SAME ADJACENT WALLS (UNLESS NOTED
OTHERWISE) WHERE GYPSUM BOARD CONTINUES ABOVE CEILING AND ABOVE THE CEILING LEVEL
UP TO THE STRUCTURE ABOVE. ALL GYPSUM BOARD RETURNS SHALL HAVE CORNER BEADS
MINIMUM FLOOR TO CEILING. ALL PENETRATIONS IN GYPSUM BOARD CONSTRUCTION ABOVE
FINISHED CEILING SHALL BE EFFECTIVELY SEALED TO PREVENT SOUND LEAKAGE AND FIRE
STOPPING TAPE/CAULK AT ALL RATED PARTITIONS.
8. ALL MECHANICAL CHASES AND OTHER NOTED CHASES ARE TO EXTEND UP TO THE UNDERSIDE OF
THE DECK STRUCTURE ABOVE. ALL PLUMBING CHASES, UNLESS OTHERWISE NOTED, SHALL
EXTEND ABOVE THE HIGHEST ADJOINING CEILING AND BE BRACED TO STRUCTURE.
9. ALL CONSTRUCTION DESIGNATED TO BE SUPPORTED BY ROOF STRUCTURE SHALL BE SUPPORTED
BY TOP CHORD OF STRUCTURAL JOISTS AND NOT FROM THE METAL DECK.
10. COORDINATE WITH MILLWORK DRAWINGS FOR PLACEMENT OF BLOCKING IN WALLS / PARTITIONS.
ALL WOOD BLOCKING IS TO BE FIRE RETARDANT TREATED.
11. IMPACT RESISTANT GYPSUM BOARD, WHERE NOTED, IS OPTIONAL ABOVE 8' AFF AND BEHIND
LOCKERS.
12. SEAL THE TOP AND BOTTOM OF WALL, AS WELL AS ALL PENETRATIONS WHERE SMOKE
PARTITIONS ARE DESIGNATED ON THE LIFE SAFETY PLAN, TO ELIMINATE THE PASSAGE OF SMOKE.
13. USE DEFLECTION TRACKS WHERE STUD WALLS ATTACH DIRECTLY TO METAL DECK.
GENERAL PARTITION NOTES
UNDERSIDE OF STRUCTURE
FIRE RATED SEALANT
AROUND PERIMETER
DIM DIM
DEFLECTION TRACK
WHERE NEEDED
DEFLECTION TRACK AS REQUIRED
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
KS ARCH REG. NO. A-930, EXP. 12/31/2023
KS ENGR REG. NO. E-2586, EXP. 12/31/2023
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGR
SPUR DESIGN
25219 MADISON AVENUE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT HEALTH & SAFETY
1139 OLIVE STREET,
ST. LOUIS, MO 63101
(314) 436-9492
HEALTHCARE PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, STE 1415
PANAMA CITY, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:SPUR #: 2016
/2
/2
:4 :5
A
M
AE001
PARTITION TYPES
ECO
39 OF 190AJS
100% BID SET
CONSTRUCT INFILL OF
BUILDING 26 AND RENOVATE
SPECIALTY CARE CLINICS
12/21/2022
589-704
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
MARK WALL TYPE DESCRIPTION WIDTH MIN. STC
X3 1 HR ICRA (U419)
5/8" TYPE X GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD AT
16" O.C.
4 7/8" --
MARK WALL TYPE DESCRIPTION WIDTH MIN. STC
V1 NON-INSULATED CMU BLOCK TO MATCH EXISTING ADJACENT CONSTRUCTION. 7 5/8"
MARK WALL TYPE DESCRIPTION WIDTH MIN. STC
U3 NON-INSULATED
5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD SPACED AT
16" O.C.
4 7/8"
U6 NON-INSULATED
5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD SPACED AT
16" O.C.
7 1/4" --
MARK WALL TYPE DESCRIPTION WIDTH MIN. STC
S3 NON-INSULATED
5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD SPACED AT
16" O.C. WITH LEAD LINING
4 29/32" --
MARK WALL TYPE DESCRIPTION WIDTH MIN. STC
R3
INSULATED
(U419)
5/8" GYPSUM BOARD EACH SIDE OF 6" METAL STUD SPACED AT 16"
O.C. W/ BATT INSULATION AND FIBER-REINFORCED (FRP) PANEL
BOTH SIDES
8" 49 STC
R4 INSULATED
5/8" GYPSUM BOARD ONE SIDE OF 3 5/8" METAL STUD SPACED AT
16" O.C. W/ BATT INSULATION AND RESILIENT CHANNEL AND
FIBER-REINFORCED PANEL (FRP) ONE SIDE
4 7/8" 49 STC
MARK WALL TYPE DESCRIPTION WIDTH MIN. STC
G2 1 HR (U415)
5/8" TYPE X GYPSUM BOARD ONE SIDE & 1" TYPE X GYPSUM
BOARD OPPOSITE SIDE OF 2 1/2" CH METAL STUD AT 16" O.C. W/
BATT INSULATION
3 1/8"
G4 1 HR (U415)
5/8" TYPE X GYPSUM BOARD ONE SIDE & 1" TYPE X GYPSUM
BOARD OPPOSITE SIDE OF 4" CH METAL STUD AT 16" O.C. W/ BATT
INSULATION
4 5/8" 51 STC
MARK WALL TYPE DESCRIPTION WIDTH MIN. STC
F3 1 HR (U419)
5/8" TYPE X GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD AT
16" O.C.
4 7/8"
MARK WALL TYPE DESCRIPTION WIDTH MIN. STC
E3 CARRIER
5/8" GYPSUM BOARD ONE SIDE OF (2) 3 5/8" METAL STUD WALLS AT
16" O.C. W/ BATT INSULATION ONE SIDE
1'-3 7/8" --
MARK WALL TYPE DESCRIPTION WIDTH MIN. STC
C3 NON-INSULATED 5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD AT 16" O.C. 4 7/8"
C6 NON-INSULATED 5/8" GYPSUM BOARD EACH SIDE OF 6" METAL STUD AT 16" O.C. 7 1/4"
D3
INSULATED
(U419)
5/8" GYPSUM BOARD EACH SIDE OF3 5/8" METAL STUD AT 16" O.C.
W/ BATT INSULATION
4 7/8"
MARK WALL TYPE DESCRIPTION WIDTH MIN. STC
A1 NON-INSULATED 5/8" GYPSUM BOARD ONE SIDE 7/8" HAT CHANNEL AT 16" O.C. 1 1/2" --
A2 NON-INSULATED 5/8" GYPSUM BOARD ONE SIDE OF 2 1/2" METAL STUD AT 16" O.C. 3 1/8"
A3 NON-INSULATED 5/8" GYPSUM BOARD ONE SIDE OF 3 5/8" METAL STUD AT 16" O.C. 4 1/4"
A6 NON- INSULATED 5/8" GYPSUM BOARD ONE SIDE OF 6" METAL STUD AT 16" O.C. 6 5/8" --
UP
BLDG 61
BLDG 29BLDG 62
B
B62
B
B
B
B
B
B
B
B29
B3
BLDG 26
H J K L M
WORKSTATIONS
001A
WORKSTATIONS
001A
GUEST
SERVICES
HOLDING
CELL
001B
HOLDING
CELL
001B
HOLDING
CELL
001C
HOLDING
CELL
001C
STAIR
FREEZER
025D
FOOD STG
025A
COOLER
025C
FOOD STG
025B
DISH WASH KITCHEN
CORRIDOR
C1
RETAIL
STORAGE
024A
RETAIL
STORE
DINING AREA
SERVING LINE SAFE
026B
VCS CHIEF
OFFICE
026A
VCS OFFICE
DINING AREA
VENDOR
022A
CORRIDOR
C2
VESTIBULE
032A
AE301
12'-0" 19'-0" 19'-0" 19'-0" 19'-0" 19'-0" 7'-0" 12'-0" 13'-10 1/2" 5'-1 1/2" 12'-2"
'-4
8'
-4
'-6
7'
-9
7' -1
1/
2" 7'
-9
/2
7' -9
/2
7'
-1
1/ 2"
7' -9
'-4
8' -6
'-4
LAB
DTR-1
DTR-2
DTR-3
DTR-4
DTR-5
DTR-6
DTR-7
DTR-8
CHIEF
035B
WORKSTATIONS
RECEPTION
035A
COPY /
SUPPLY
035F
LOCKER
035C
DRESSING
035E LOUNGE
035D
IT ROOM
HAC
DENTAL
MECH
STORAGE
ELEC
CLEAN
SUPPLY
STERILE
EQUIPMENT
MOBILE
EQUIPMENT
X-RAY
WAITING
ENTRY
CHECK-IN
KIOSK
034A
WC ALC.
034B
STF TLT
PAT TLT
MEDICATION
TRAY
STORAGE
SOILED
UTILITY
CAD/CAM
CART
A008
EQUIP
A007
LIFT
A006
EQUIP
A005
WC
A004
EQUIP
A003
EQUIP
A002
CRASH CART
A001
CORRIDOR
C3
ELECTRICAL
AE301
A
SECURITY
157'-2"
AE121
AE111
3'
-2
AE121
P U
M P
R O
O M
FEC FEC
FEC
FEC
FEC FEC
KEY PLAN
BLDG 26
BLDG 3 BLDG 1
BLDG 2BLDG 19
BLDG 61
BLDG 62
BLDG 29
N
PHASE FOUR
SERVICE YARD
1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT
WALL UNLESS NOTED OTHERWISE.
2. ALL WALLS ARE TYPE D3 PARTITIONS UNLESS OTHERWISE NOTED.
REFER TO PARTITION TYPE SHEET (AE001) FOR WALL TYPES.
3. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.
4. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.
5. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW
TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.
6. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.
7. PROVIDE CONTINUOUS 1 HOUR FIRE RATED EXPANSION MATERIAL AT EACH LEVEL BETWEEN
THE EXISTING BUILDING AND THE NEW INFILL CONSTRUCTION.
8. REFER TO PHASE SPECIFIC SHEETS FOR SCOPE AND EXTENT OF EACH PHASE OF WORK.
GENERAL PLAN NOTES
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF PROJECT
SCOPE SHOWN. REFERENCE GI011 - PHASING PLANS FOR MORE INFORMATION.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
KS ARCH REG. NO. A-930, EXP. 12/31/2023
KS ENGR REG. NO. E-2586, EXP. 12/31/2023
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGR
SPUR DESIGN
25219 MADISON AVENUE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT HEALTH & SAFETY
1139 OLIVE STREET,
ST. LOUIS, MO 63101
(314) 436-9492
HEALTHCARE PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, STE 1415
PANAMA CITY, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:SPUR #: 2016
/2
/2
:4 :5
A
M
AE101
OVERALL REFERENCE PLAN - GROUND
FLOOR
ECO
40 OF 190AJS
100% BID SET
CONSTRUCT INFILL OF
BUILDING 26 AND RENOVATE
SPECIALTY CARE CLINICS
12/21/2022
589-704
5500 EAST KELLOGG AVENUE
WICHITA, KANSAS 67218
N
1/8" = 1'-0"
OVERALL GROUND FLOOR PLAN1
UPUP
UP
B C D E F G
BLDG 61
BLDG 29BLDG 62
B
B62
B
B
B
B
B
B
B
B29
B3
BLDG 26
H J K L M
AE301
M E
C H
A N
IC
A
L C
H A
S E
SHARED
WAITING
100A
NEURO
NEURO
GI / RHEUM
GI / RHEUM
GI EXAM
GI EXAM
LOUNGE /
LOCKER
CLEAN
UTILITY
PAT TLT
NEURO
TEAM SPACE 1
GI EXAM
GI / RHEUM
CORRIDOR
CORRIDOR
RECEPTION
100B
CORRIDOR
PROC TLT
123B
MED EQUIP
STORAGE
PROCEDURE
ROOM
123A
MEDICATION
PFT
126A
PFT TLT
126B
SOILED
UTILITY
HAC
RENAL
HOME
OXYGEN
RENAL
RENAL
PULM / SLEEP
PULM / SLEEP
PULM / SLEEP
CPAP CONS.
FLEX EXAM
C-PAP STG
147PAT. TLT
VESTIBULE
122B
CPAP CONS.
141A
CPAP CONS.
143A
PULM / SLEEP
RENAL
CLEAN
UTILITY
RENAL
TEAM SPACE
122A
STF TLT
STG
141B STG
143B
CORR.
O2, FULL
129B
O2, EMPTY
129A
IT ROOM
ELEC
CRASH CART
A102
ALCOVE
A101
AE301
12'-0" 19'-0" 19'-0" 19'-0" 19'-0" 19'-0" 7'-0" 12'-0" 13'-10 1/2" 5'-1 1/2" 12'-2"
'-4
8'
-4
'-6
7'
-9
7' -1
1/
2" 7'
-9
/2
7' -9
/2
7'
-1
1/ 2"
7' -9
'-4
8' -6
'-4
STF TLT
M E
C H
A N
IC
A
L C
H A
S E
A AE121
157'-2"
AE111
RECEPTION
100C
FEC
FEC
FEC
FEC
FEC
KEY PLAN
BLDG 26
BLDG 3 BLDG 1
BLDG 2BLDG 19
BLDG 61
BLDG 62
BLDG 29
N
PHASE FOUR
SERVICE YARD
1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT
WALL UNLESS NOTED OTHERWISE.
2. ALL WALLS ARE TYPE D3 PARTITIONS UNLESS OTHERWISE NOTED.
REFER TO PARTITION TYPE SHEET (AE001) FOR WALL TYPES.
3. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.
4. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.
5. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW
TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.
6. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.
7. PROVIDE CONTINUOUS 1 HOUR FIRE RATED EXPANSION MATERIAL AT EACH LEVEL BETWEEN
THE EXISTING BUILDING AND THE NEW INFILL CONSTRUCTION.
8. REFER TO PHASE SPECIFIC SHEETS FOR SCOPE AND EXTENT OF EACH PHASE OF WORK.
GENERAL PLAN NOTES
PHASING AND PROJECT SCOPE LEGEND
AREAS OF WORK OUTSIDE OF CURRENT PHASE OR OUTSIDE OF PROJECT
SCOPE SHOWN. REFERENCE GI011 - PHASING PLANS FOR MORE INFORMATION.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
KS ARCH REG. NO. A-930, EXP. 12/31/2023
KS ENGR REG. NO. E-2586, EXP. 12/31/2023
STRUCTURAL / CIVIL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGR
SPUR DESIGN
25219 MADISON AVENUE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT HEALTH & SAFETY
1139 OLIVE STREET,
ST. LOUIS, MO 63101
(314) 436-9492
HEALTHCARE PLANNER
INNOVA GROUP
3196 N. SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD,…
This is the start of the file's text. The full file is on GovTribe.