Attachment 5_Plans_Final.pdf
PDF 14 MB Posted
- Solicitation number
- 1240LU26Q0030
- Issued by
-
Department of Agriculture Forest Service
About this file
This file is a 100% construction documents set for the Building 105 Bakery Renovation at USFS Fort Missoula in Missoula, Montana, prepared under Design Contract 12034019D0001 and Design Order 1240LU23F0047 Option Item 01. The project involves the renovation of an existing one-story, 2,708 square-foot building originally constructed as a bakery and being converted to a millwork/cabinet shop. The design was prepared by Mosaic Architecture, P.C. (Helena, MT) as the architect, with Morrison Maierle (Missoula, MT) providing mechanical/plumbing and electrical engineering, Great West Engineering (Great Falls, MT) providing civil engineering, and includes comprehensive construction documents across 42 sheets.
The project complies with the 2021 International Building Code, 2024 NFPA 101, and other applicable codes. The building is classified as F-1 (Moderate Hazard Storage) occupancy with a calculated occupant load of 25 persons and actual floor area of 2,708 square feet, which is well below the 14,875 square-foot allowable area. Construction documents include architectural, electrical, plumbing, mechanical, and civil drawings with detailed floor plans, elevations, sections, schedules, and specification information. The project contains seven bid option items: covered storage, water main and hydrant, compressed air system, equipment relocation, gravel parking area, ABA parking spot, and concrete sidewalk. Exit requirements include two means of egress with maximum travel distances of 58 feet and proper fire-rated wall construction with appropriate opening protections throughout the building.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
SHEET OF 42
SHEET SIZE 24x36. WRITTEN
SCALES ARE ACCURATE
PLOTTED 24x36. TEST LINE
BELOW 2" IF PLOTTED FULL
SIZE:
2"
4/
/2
9:
:5
A
M
3/31/2025
A000
COVER
USFS Fort Missoula, Missoula, MT
BUILDING 105 - BAKERY
RENOVATION
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
BUILDING 105 - BAKERY RENOVATION
DESIGN CONTRACT: 12034019D0001
DESIGN ORDER: 1240LU23F0047 OPTION ITEM 01
MOSAIC ARCHITECTURE
MOSAIC ARCHITECTURE, P.C.
317 CRUSE AVE., SUITE 201
HELENA, MT 59601
(406) 449-2013
ARCHITECT:
MECHANICAL/PLUMBING ENGINEERING:
SHEET INDEX
PROJECT DIRECTORY
VICINITY MAP
PROJECT SITE
ARCHITECTURAL DRAWINGS
A000 COVER
A001 CODE INFORMATION
A002 GENERAL INFO. & ASSEMBLY & DOORS
A003 EXISTING FLOOR PLAN & PHOTOS
A004 DEMOLITION PLANS
A100 SITE PLAN
A101 FLOOR PLAN & SCHEDULES
A102 ROOF PLAN & EXT. DETAILS
A103 REFLECTED CEILING PLAN
A104 EQUIPMENT PLAN
A201 EXTERIOR ELEVATIONS
A202 WOOD STORAGE PLAN & ELEVATIONS
A301 BUILDING SECTIONS
A501 DOORS & WINDOWS
A801 FINISH PLAN
A802 ENLARGED PLANS & INTERIOR ELEVATIONS
MORRISON MAIERLE
1055 Mount Avenue
MISSOULA MT 59801
(406) 751-5867
ELECTRICAL ENGINEERING:
MORRISON MAIERLE
1055 Mount Avenue
MISSOULA MT 59801
(406) 751-5867
CIVIL ENGINEERING:
GREAT WEST ENGINEERING
720 2nd STREET
GREAT FALLS, MT 59405
USFS REPRESENTATIVE: SEE SOLICATION MATERIALS FOR ASSIGNMENT OF
REPRESENTATIVE
ELECTRICAL DRAWINGS
E001 ELECTRICAL SYMBOLS AND ABBREVIATIONS
E002 ELECTRICAL DETAILS
E003 ELECTRICAL SCHEDULES
E004 PANEL SCHEDULES
E005 ELECTRICAL DEMOLITION PLAN
E101 ELECTRICAL LEVEL 1 POWER PLAN
E201 ELECTRICAL LEVEL 1 LIGHTING PLAN
PLUMBING DRAWINGS
P001 PLUMBING LEGEND & NOTES
P002 PLUMBING DETAILS
P003 PLUMBING SCHEDULES
P004 MEP COORDINATION SCHEDULE
P100 PLUMBING UNDERSLAB PLAN
P102 PLUMBING LEVEL 1 PLAN
P103 PLUMBING ROOF PLAN
MECHANICAL DRAWINGS
M001 MECHANICAL LEGEND & NOTES
M002 MECHANICAL DETAILS
M003 MECHANICAL SCHEDULES
M004 MEP COORDINATION SCHEDULE
M101 MECHANICAL LEVEL 1 PLAN
M102 DUST COLLECTION EXHAUST PLAN
M103 MECHANICAL ROOF PLAN
CIVIL DRAWINGS
C001 EXISTING SITE AND DEMOLITION PLAN
C002 OVERALL SITE PLAN
C003 ENLARGED SITE PLAN
C004 DETAILS
C005 DETAILS
UNITED STATES FOREST SERVICE
BUILDING 105, FORT MISSOULA
FORT MISSOULA, MISSOULA, MT
# DATE REVISION
APPROVED BY:
RECOMMENDED BY:
R1 DIRECTOR OF
ENGINEERING & FLEET
R1 FACILITIES
PROGRAM MANAGER
DEPUTY REGIONAL
FORESTER
RECOMMENDED BY:
JeffD Text Box
WH
T
T
T
F
F
F
F
F
SD
58'
GROSS
182 SF
B
GROSS
2385 SF
F-1
MAX. EXIT TRAVEL
= 58 FEET
NOT AN
EXIT
EXIT 2
EXIT 1
NOT AN
EXIT
A
E
E
NOT AN EXIT
FE
FE
0' 4' 8' 16'
C
NON-RATED WALL: WITH NO OPENING PROTECTION REQUIRED AT DOORS, WINDOWS,
DUCTS, PENETRATIONS, AND JOINTS . SEE WALL TYPES.
EXIT SIGN W/ INTEGRATED DIRECTIONAL ARROW WHERE OCCURS AT ALL EXITS,
EVERY 100' IN CORRIDORS, AND IN SPACES WHERE 2 MEANS OF EGRESS ARE
REQUIRED PER S §1006. SEE ELECTRICAL DRAWINGS. (W/ POCHE IN QUADRANT
INDICATING "EXIT" TEXT SIDE OF SIGN.) SIGNS SHOWN IN CORRIDORS ARE CEILING
HUNG. SIGNS SHOWN ON WALL ARE WALL HUNG.
1-HOUR FIRE WALL, FIRE BARRIER, FIRE PARTITION, OR SMOKE BARRIER WALL: OR COMBINATION OF
(WHERE OCCURS) CONFORMING TO THE MOST STRINGENT REQUIREMENTS OF EACH. SEE CODE
ANALYSIS PLANS FOR SPECIFIC NAMES OF IBC WALL DESIGNATIONS. ALL WITH FIRE-RESISTIVE OPENING PROTECTION AT DOORS, WINDOWS, DUCTS (WITH EXCEPTIONS), PENETRATIONS, AND PROTECTION AT JOINTS. SEE WALL TYPES, DOOR AND WINDOW SCHEDULES, MECHANICAL DRAWINGS, PENETRATION
DETAILS, AND JOINT DETAILS WHERE APPLICABLE.
2-HOUR FIRE WALL OR FIRE BARRIER: OR COMBINATION OF (WHERE OCCURS) CONFORMING TO THE MOST STRINGENT REQUIREMENTS OF EACH. SEE CODE ANALYSIS PLANS FOR SPECIFIC NAMES OF IBC WALL DESIGNATIONS. ALL WITH FIRE-RESISTIVE OPENING PROTECTION AT DOORS, WINDOWS, DUCTS (WITH EXCEPTIONS), PENETRATIONS, AND PROTECTION AT JOINTS. SEE WALL TYPES, DOOR AND WINDOW SCHEDULES, MECHANICAL DRAWINGS, PENETRATION DETAILS, AND JOINT DETAILS
WHERE APPLICABLE.
PORTABLE CLASS ABC FIRE EXTINGUISHER IN ADA-COMPLIANT
SURFACE CABINET. PROVIDE 2, SEE PLAN.
FE
Wmin
MINIMUM EGRESS WIDTH (INCHES) BASED ON ACCUMULATIVE NUMBER OF
OCCUPANTS SERVED AT INDICATED EGRESS COMPONENT, PER SECTION
1005.3: .3 INCHES/OCC FOR STAIRWAYS(NON-SPRINKLERED BUILDINGS); .2
INCHES/OCC FOR OTHER EGRESS COMPONENTS (NONSPRINKLERED BLDGS).
MOER:2 MEANS OF EGRESS REQUIRED (QUANTITY). ONLY
DESIGNATED WHERE (2) MEANS OF EGRESS ARE
REQUIRED, PER §1006.2.1.
ACCESSORY OCCUPANCY AREA: W/ NO SEPARATION REQUIRED AND
CALCULATED AS PART OF MAIN OCCUPANCY IF TOTAL ACCESSORY
OCCUPANCIES WITHIN A STORY OCCUPY LESS THAN 10% OF AREA OF
THAT STORY, PER SECTION 508.2.3.
CODE PLAN LEGEND
OCCUPANCY GROUP F-1
AREA
EXIT ACCESS TRAVEL DISTANCE (E.A.T.D.) - MAXIMUM 200' FOR 'B' OCCUPANCY
W/OUT SPRINKLER SYSTEM, PER TABLE 1017.2. MAXIMUM DISTANCE FOR EACH
STORY SHOWN.
COMMON PATH OF EGRESS TRAVEL (C.P.E.T.) - MAXIMUM 75' FOR 'B' OCCUPANCY
W/OUT SPRINKLER SYSTEM, OCC LOAD >30, PER TABLE 1006.2.1.
ROOM AREA
OCCUPANT LOAD
MAX. FLOOR AREA
PER OCCUPANT
FROM TABLE 1004.5
SF
ROOM NAME
OCCUPANT LOADS FOR FUNCTIONS DESIGNATED NET FLOOR AREA IN TABLE
1004.5 ARE IDENTIFIED FOR ACTUAL OCCUPIED AREAS.
OCCUPANT LOADS FOR FUNCTIONS DESIGNATED GROSS FLOOR AREA ARE
IDENTIFIED FOR ENTIRE AREA OF THE FUNCTION W/ DEDUCTIONS ONLY FOR AREA
OF EXTERIOR WALLS, VENT SHAFTS AND INTERIOR COURTS.
AO
OCCUPANCY GROUP B - ACCESSORY TO F OCCUPANCY
(F OCCUPANCY DICTATES)
REQUIRED EXIT AND EXIT EGRESS DIRECTION WITH ACCUMULATIVE NUMBER
OF OCCUPANTS SERVED. (DESIGNATED WHERE (2) MEANS OF EGRESS ARE
REQUIRED PER TABLE §1006.2.1)
N O
T U
S E
D N
O T
U S
E D
THIS PROJECT SHALL COMPLY WITH THE LATEST EDITION OF CODES
PUBLISHED BY MODEL CODE ORGANIZATIONS:
2021 International Building Code (IBC)
2024 NFPA 101
2021 International Fire Code (IFC) 2021 International Mechanical Code (IMC) 2021 International Fuel Gas Code (IFGC) 2021 International Plumbing Code (IPO) 2023 National Electrical Code (NEC) 2021 International Fire Code (IFC) 2021 International Energy Conservation Code (IECC)
PRIMARY APPLICABLE BUILDING CODES
ZONING AND PARKING REGULATIONS
THIS PROJECT HAS NO APPLICABLE ZONING OR PARKING REGULATIONS.
ABA REQUIRES ACCESS TO AN ACCESSIBLE PARKING SPOT AND AN
ACCESSIBLE ROUTE TO THE BUILDING, BOTH ARE OPTION ITEMS.
OCCUPANCY GROUPS:
(CHAPTER 3)
• F-1 - MODERATE HAZARD STORAGE (THIS
OCCUPANCY DICTATES)
• B - ACCESSORY OCCUPANCIES PER SEC. 508.2
• INCIDENTAL USES PER TABLE 509 WHERE OCCUR.
NON-SEPARATED
OCCUPANCIES:
(SEC. 508.3.2)
CONSTRUCTION TYPE:
(TABLE 601)
ALLOWABLE FLOOR AREA (At):
(TABLE 506.2)
ALLOWABLE FLOOR AREA:
1 STORY BLDG: (Aa)
(SEC. 506.2.1)
F-1:
ALLOWABLE NO. OF STORIES /
HEIGHT:
(TABLE 504.4/504.3)
F-1: 2 STORIES / 40 FT
*MOST RESTRICTIVE REQUIREMENTS GOVERN
OCCUPANT LOAD BY
FLOOR:
LEVEL 1 25
SEE CODE ANALYSIS PLANS THIS SHEET.
SUMMARY CODE REVIEW
PROJECT
DESCRIPTION:
REMODEL OF EXISTING BUILDING. NO CHANGE IN
OCCUPANCY. ORIGINALLY USED AS A BAKERY AND
BEING CONVERTED TO MILLWORK/CABINET SHOP
ACTUAL NO. OF STORIES /
HEIGHT:
1 STORY / 24 FT; OK
OCCUPANT LOADS FOR
EGRESS DESIGN:
(SEC. 1004 + TABLE 1004.5)
INDUSTRIAL AREAS 100
GROSS
EGRESS WIDTH PER OCCUPANT
SERVED:
(SEC. 1005.3)
EGRESS
COMPONENTS:
0.2 INCHES / OCCUPANT (NON-
SPRINKLERED)
INTERIOR FINISH
REQUIREMENTS:
(TABLE 803.13)
INTERIOR EXIT STAIRWAYS, EXIT RAMPS & EXIT
PASSAGEWAYS: CLASS A.
CORRIDORS & ENCLOSURE FOR EXIT ACCESS
STAIRWAYS & EXIT ACCESS RAMPS: CLASS B. ROOMS
AND ENCLOSED SPACES: CLASS C
THIS PROJECT CONTAINS BID OPTION ITEMS,
BRIEFLY SUMMARIZED BELOW. SEE SPECIFICATION
SECTION 01 2300 FOR COMPLETE DETAILED LIST OF
OPTION ITEMS.
OPTION ITEM 1 - COVERED STORAGE
OPTION ITEM 2 - WATER MAIN AND HYDRANT
OPTION ITEM 3 - COMPRESSED AIR SYSTEM
OPTION ITEM 4 - EQUIPMENT RELOCATION
OPTION ITEM 5 - GRAVEL PARKING AREA
OPTION ITEM 6 - ABA PARKING SPOT
OPTION ITEM 7 - CONCRETE SIDEWALK
Aa = At + [NS x If] Aa = 8,500 + [8,500 x .75] Aa = 14,875 SF
ACTUAL FLOOR AREA: 2,708 SF <14,875 ALLOWABLE; OKEXISTING:
32" CLEAR AT DOORS [§1010.1.1],
44" AT CORRIDORS, AISLES & EXIT PASSAGEWAYS (36"
for occupant load <50) [§ 1020.2; 1018.3, 1018.5; 1024.2
RESPECTIVELY], PROVIDED.
EGRESS WIDTH MINIMUMS BY
COMPONENT (USE WHERE
EXCEED MINIMUMS BY
OCCUPANT LOAD):
CORRIDOR FIRE RESISTANCE
RATING:
(TABLE 1020.2)
F OCCUPANCY,
OCC LOAD <30:
NOT REQUIRED
(NONSPRINKLERED)
OPENING PROTECTIVES:
(TABLE 716.1(2))
20 MINUTE
D-20
DH-OH-20
45 MINUTE
OH-45 OR W-60
1-HR FIRE PARTITIONS (CORRIDOR
WALLS):
FIRE DOOR RATING:
DOOR VISION PANEL GLAZING
MARKING:
SIDELIGHT/TRANSOM ASSEMBLY
MARKING:
FIRE WINDOW ASSEMBLY RATING:
WINDOW ASSEMBLY MARKING:
(TABLE 716.1(3))
FRONTAGE INCREASE (If):
(TABLE 506.3.3)
>30' OPEN SPACE FOR 100% OF BLDG PERIMETER:
If = .75
NO RATED CONSTRUCTION
FIRE SPRINKLERS: 903.2.4 F FIRE SPRINKLERS REQUIRED
WHERE FIRE AREA EXCEEDS 12,000
SF. NOT APPLICABLE.
FIRE ALARM & DETECTION: 907 907.2.4 GROUP F: FIRE ALARM SYSTEM SHALL BE
INSTALLED WHERE STRUCTURE IS TWO OR MORE
STORIES IN HEIGHT OR HAS OCCUPANT LOAD OVER
500. NOT APPLICABLE
(CHAPTER 6) CONSTRUCTION TYPE V-B; GROUP F-1
OCCUPANCY
BUILDING ELEMENT
TABLE 601 STRUCTURAL FRAME
RATING
0 HR
TABLE 602 EXTERIOR BEARING WALLS: FIRE SEP <5' 2 HR - N/A
TABLE 601 INTERIOR BEARING WALLS 0 HR
TABLE 602 EXTERIOR NONBEARING WALLS: FIRE SEP <5' 2 HR - N/A
TABLE 601 FLOORS 0 HR
EXTERIOR BEARING WALLS: FIRE SEP <10' 0 HR
EXTERIOR BEARING WALLS: FIRE SEP ≥10'
0 HR
EXTERIOR NONBEARING WALLS: FIRE SEP ≥5',<10' 1 HR - N/A
TABLE 601 ROOFS 0 HR
EXTERIOR BEARING WALLS: FIRE SEP ≥5',<10' 1 HR - N/A
EXTERIOR NONBEARING WALLS: FIRE SEP ≥10' 0 HR
MAXIMUM AREA OF EXTERIOR OPENINGS
(CHAPTER 7) MAXIMUM AREA OF EXTERIOR OPENINGS PER TABLE 705.8:
NON-SPRINKLERED
EAST WALL - SEPARATION ≥30 FT
UNPROTECTED NO LIMIT
PROTECTED NO LIMIT
FIRE-RESISTANCE RATING REQUIREMENTS
TYPE OF CONSTRUCTION
WEST WALL - SEPARATION ≥30 FT
UNPROTECTED NO LIMIT
PROTECTED NO LIMIT
NORTH WALL - SEPARATION ≥30 FT
UNPROTECTED NO LIMIT
PROTECTED NO LIMIT
SOUTH WALL - SEPARATION ≥30 FT
UNPROTECTED NO LIMIT
PROTECTED NO LIMIT
0 HR
REQUIRED SPECIAL INSPECTIONS:
IN ADDITION TO REGULAR INSPECTIONS, THE FOLLOWING ITEMS WILL ALSO
REQUIRE SPECIAL INSPECTIONS AND TESTING IN ACCORDANCE WITH SECTIONS
1704 AND 1705 OF THE 2021 INTERNATIONAL BUILDING CODE. SEE STRUCTURAL
FOR SPECIFIC REQUIREMENTS. GENERAL CONTRACTOR IS REQUIRED TO HIRE
AND COORDINATE 3RD PARTY INSPECTIONS. COPIES OF 3RD PARTY REPORTS TO
BE SENT TO C.O. & COPIES KEPT ON-SITE FOR INSPECTOR REVIEW.
a) SPECIAL INSPECTIONS:
- INSPECTION OF FABRICATORS (1704.2.5) - NA
- STEEL CONSTRUCTION (1705.2) - NA
- CONCRETE CONSTRUCTION (1705.3) - NA
- MASONRY CONSTRUCTION (1705.4) - NA
- WOOD CONSTRUCTION (1705.5) - NA
- SOILS (1705.6) - NA
- SPECIAL CASES (1705.1.1)
EPOXY SET ANCHORS - FOR WOOD STORAGE STRUCTURE
POWDER-ACTUATED FASTENERS - NA
CONCRETE EXPANSION ANCHORS - FOR WOOD STORAGE
STRUCTURE
b) SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE (1705.12):
- STRUCTURAL STEEL (1705.12.1) - WOOD STORAGE STRUCTURE
- STRUCTURAL WOOD (1705.12.2) - NA
- COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION (1705.12.3) - NA
IECC COMPLIANCE FOR COMMERCIAL PROJECTS
CLIMATE ZONE: 6
INSULATION REQUIREMENTS - IECC 2021 TABLE C402.1.3/C402.4
ROOFS R-30 CONTINUOUS ABOVE DECK, R-49 AT ATTICS
METAL FRAMED WALLS, ABOVE GRADE R-13 CAVITY + R-7.5 CONTINUOUS
WOOD FRAMED WALLS, ABOVE GRADE R-13 CAVITY + R-7.5 CONTINUOUS OR R-20 +
R-3.8 CONTINUOUS
MASS WALLS, ABOVE GRADE: R 13.3 CONTINUOUS
BELOW GRADE WALLS: R-10 CONTINUOUS
FLOORS - JOIST/FRAMING: R-30 (R-38 FOR STEEL FLOOR JOISTS)
UN-HEATED SLAB: R-20 VERTICAL FOR 24" BELOW (FULL HEIGHT OF
THICKENED SLAB EDGE)
HEATED SLAB: R-15 FOR 36" BELOW + R-5 FULL SLAB
OPAQUE SWINGING DOORS: U-0.37
ROLL UP OR SLIDING DOORS R-4.75
OPERABLE FENESTRATION U FACTOR0.42 MAXIMUM
FIXED FENESTRATION U-FACTOR: 0.34, MAXIMUM
ENTRANCE DOOR: 0.63, MAXIMUM
SHGC 0.40 WITH ADJUSTMENT FOR PROJECTION FACTOR >.2
THIS PROJECT IS AN IECC LEVEL 2 RENOVATION THAT DOES NOT IMPACT BUILDING
SHELL OR OCCUPANCY. ONLY ELEMENTS MODIFIED OR REPLACED ARE REQUIRED TO
MEET IECC REQUIREMENTS. MODIFICATIONS INCLUDE:
ROOFS R-50 BLOWN-IN FIBERGLASS INSULATION ADDED TO
ATTIC
WOOD FRAMED WALLS: NA
UNHEATED SLAB: NA - EXISTING
OPAQUE SWINGING DOORS: NA - EXISTING HISTORIC DOORS
FENESTRATION U-FACTOR (FIXED): NA - EXISTING HISTORIC WINDOWS
FENESTRATION U-FACTOR (OPERABLE): NA - EXISTING HISTORIC WINDOWS
ENTRANCE DOOR: NA - EXISTING HISTORIC DOORS
PLUMBING FIXTURE COUNTS
FIXTURE TYPE
WC, MALE:
WC, FEMALE:
FIXTURES
REQUIRED
1:100 1:100
BU
SI
N
ES
S
NO.
OCC.
TOTAL
REQUIRED
0.15 0.15
FIXTURES
PROVIDED
1 WC
LAVS, :
DF:
UTILITY SINK
1 PER 1 WC
ALT. WATER
PROVIDED
OCCUPANT LOAD = 25
DUST COLLECTION REQUIREMENTS:
IFC 2203.1 CRITICAL DEPTH LAYER:
THE MAXIMUM DUST LAYER ON ALL SURFACES, INCLUDING BUT NOT LIMITED TO
WALLS, CEILINGS, BEAMS, EQUIPMENT, FURNITURE, PIPES AND DUCTS, SHALL NOT
EXCEED THE CRITICAL DEPTH LAYER SPECIFIED IN TABLE 2203.1. THE CRITICAL
DEPTH LAYER IS PERMITTED TO BE ADJUSTED FOR EXPLOSION HAZARD WHERE
FURTHER EVALUATED IN ACCORDANCE WITH ONE OF THE FOLLOWING:
-4.1.3.3 OF NFPA 664
CRITICAL DUST COLLECTION DEPTH (TABLE 2203.1): WOOD FLOUR - 1/8"
IFC 2203.2 Dust- Producing and Dust Handling Equipment
DUST-PRODUCING EQUIPMENT AND DUST-HANDLING EQUIPMENT, INCLUDING BUT
NOT LIMITED TO VACUUMS, DUST COLLECTION SYSTEMS, DRYERS, MIXERS,
BLENDERS, SEPARATORS, CONVEYORS, STORAGE CONTAINERS, SILOS OR OTHER
SIMILAR DEVICES, SHALL BE LISTED AND SHALL BE MAINTAINED IN ACCORDANCE
WITH THE MANUFACTURER'S RECOMMENDED STANDARDS
2203.3.1 DUST-COLLECTION SYSTEMS
DUST-COLLECTION SYSTEMS SHALL BE DESIGNED TO COLLECT DUST EMISSIONS
FROM DUST-PRODUCING EQUIPMENT AT THE POINT OF GENERATION. DUST-
COLLECTION SYSTEMS SHALL BE IN ACCORDANCE WITH SECTION 511 OF THE
INTERNATIONAL MECHANICAL CODE.
EXCEPTION: CLOSED SYSTEMS USING LISTED EQUIPMENT AND DESIGNED IN
ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND
SPECIFICATIONS, WHERE CLEANOUTS ARE PROVIDED IN ACCORDANCE WITH
SECTION 2203.3.3.
HEATING, VENTILATION, AND AIR CONDITIONING (HVAC) SYSTEMS SHALL NOT BE
USED AS THE MEANS TO COLLECT DUSTS FROM LOCALIZED SOURCES.
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
SHEET OF 42
SHEET SIZE 24x36. WRITTEN
SCALES ARE ACCURATE
PLOTTED 24x36. TEST LINE
BELOW 2" IF PLOTTED FULL
SIZE:
2"
4/
/2
9:
:0
A
M
3/31/2025
A001
CODE INFORMATION
USFS Fort Missoula, Missoula, MT
BUILDING 105 - BAKERY
RENOVATION
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
CODE PLAN
1N
# DATE REVISION
OPTION ITEM SUMMARY
THIS MIXED OCCUPANCY BUILDING INCORPORATES
NON-SEPARATED OCCUPANCIES. NO OCCUPANCY
SEPARATIONS ARE PROVIDED, AND THE ALLOWABLE
AREA AND HEIGHT OF THE BUILDING IS BASED ON
THE REQUIREMENTS OF THE MOST RESTRICTIVE
OCCUPANCY - F.
TYPE VB, NON-SPRINKLERED
F-1: 8,500 SF
JeffD
@ at A.B. anchor bolt A/C air conditioning ACC PNL access panel ACOUST acoustical ACT acoustical ceiling tile AD area drain ADJ adjacent AFF above finished floor AIB air infiltration barrier ALT alternate ALUM aluminum ANOD anodized APPROX approximate ARCH architect AUTO automatic BBD bulletin board BD board BITUM bituminuous BL building line BLDG building BLK block BLKG blocking BM beam/bench mark BO by owner B.O. bottom of BOT bottom BRG bearing BSBD baseboard BTWN between B.O.W. bottom of wall BU built up CAB cabinet CAP capacity CB catch basin CL centerline C.C. center to center CDX exterior grade plywood CG corner guard CH channel CI cast iron/cubic inches CJ control joint CLG ceiling C.L.L. contract limit line CL center line
ABBREVIATIONS:
GA gauge GB grab bar GALV galvanized G.C. general contractor GEN general GFRG glass fiber reinforced gypsum GI galvanized iron GL glass GLU LAM or G.L.B.glue laminated beam GRD grade/grid GWB gypsum wall board GYP gypsum HB hose bib HC hollow core/handicapped HD BD Hard board HDR header HOR horizontal HR hour HT height HTG heating HVAC heating, ventilation, air conditioning HW hot water
PART.BD. particle board PART’N partition PC precast concrete PFM prefinished metal PL plate P.LAM plastic laminate PLWD plywood PNL panel PR pair PSL parallel strand lumber PT point PTD paper towel dispenser
T tread/thermostat TB towel bar TEL telephone TEMP temperature T&G tongue and groove THK thick THRU through TJI Truss Joist Incorporated
CLR clear CMU concrete masonry unit CO clean out COL column CONC concrete COND condition CONF conference CONN connection CONST construction CTRD centered CONT continuous CONTR contractor
C.O. CONTRACTING OFFICER
C.O.R. CONTRACTING OFFICER
REP.
CPT carpet CT ceramic tile CUH cabinet unit heater CW curtain wall system CY cubic yard DBL double DEPT department DF drinking fountain DIA diameter DIAG diagonal DIM dimension DISP dispenser DN down DR door DWR drawer DS downspout DTL detail DWG drawing E east EA each EIFS exterior insulation finish system E.J. expansion joint EL/ELEV elevation -height/elevator ELEC electrical ENCL enclosure EO electrical outlet EP electrical panel EQ equal EQUIP equipment EWA/EW exterior wall assembly EWC electrical water cooler EWH electrical water heater (E)/EXIST existing EXH exhaust EXP expansion EXT exterior
IN inch INCL included INFO information INSUL insulation INT interior IWA/IW interior wall assembly
T.O. top of T.O.B. top of beam T.O.C. top of concrete T.O.P. top of plate T.O. FTG top of footing T.O.S. top of steel T.O.SL. top of slab T.O.W. top of wall TPD toilet paper dispenser TR tread TS tubular steel TV television TYP typical UG underground UNO unless noted otherwise UR urinal VAC vacuum outlet VAR varies VB vapor barrier VCT vinyl composition tile VERT vertical VEST vestibule VFY verify VT vinyl tile VWC vinyl wall covering W west/women/width W/ with W/O without WC water closet WD wood W/D washer/dryer WH water heater WNDW window WP waterproof WR water resistant WRB weather resistive barrier WT weight WWF welded wire fabric WWM welded wire mesh X by YD yard
REINF reinforcing REQD required RES resilient RM room RO rough opening RV roof vent R&S rod and shelf S south SACT suspended acoustical ceiling tile SC solid core SCD seat cover dispenser SCHED schedule SD soap dispenser SECT section SF square feet SGL single SHT sheet SHTG sheathing SHWR shower SIM. similar S.I.P. structural insulated panel SLNT sealant SOG slab on grade SPEC specifications S.S. stainless steel SS service sink SSM solid surface material STD standard STF storefront STL steel STOR storage STRUCT structural SUBFLR subfloor SUSP suspended SV sheet vinyl SY square yard
M men's MAT material MAX maximum MECH mechanical MDF medium density fiber board MEMB membrane MEZZ mezzanine MFR manufacturer MH manhole MIN minimum MIR mirror MISC miscellaneous MO masonry opening MTL metal MULL mullion N north NA not applicable NIC not in contract NO number NTS not to scale OFCI owner furnished/contractor installed OC on center OD outside diameter OH overhead/opposite hand OPNG opening OPP opposite
FLR/FL floor FLUOR fluorescent FND feminine napkin dispenser/disposal FOC face of concrete FOF face of finish FOS face of stud FOW face of wall FT foot or feet FTG footing
QTY quantity R/RAD radius R riser RA roof/ceiling assembly RB rubber base RD roof drain RE regarding REF reference/refrigerator
JAN janitor JST joist JT joint LAV lavatory LF lineal foot LTG lighting
FA fire alarm/floor-ceiling assembly FAH fire alarm horn FAS fire alarm station FD floor drain FDN/FND foundation FE fire extinguisher FEC fire extinguisher cabinet FF finished floor FFHB frost free hose bib FG finish grade FH fire hydrant FIN. FLR top of floor sheathing FIN finish FIXT fixture F.O. face of
PTD/R paper towel dispenser/receptacle
PVMT pavement PVC polyvinylchloride
1. CONTACT THE CONTRACTING OFFICER FOR THE GENERAL CONDITIONS TO
THE CONTRACT FOR THE CONSTRUCTION
2. CONTRACT DOCUMENTS REQUIREMENTS INCLUDE THE DRAWINGS,
SPECIFICATIONS, GENERAL CONDITIONS, AGREEMENT (BUILDING
CONTRACT) AND ALL ADDENDA. THEY ARE TO INCLUDE ALL LABOR,
EQUIPMENT, AND MATERIALS NECESSARY FOR THE PROPER EXECUTION OF
THE WORK EXCEPT AS MAY BE SPECIFICALLY NOTED OTHERWISE ON THE
DRAWINGS OR FOR WHICH SEPARATE PRICES MAY BE ASKED IN THE BID
PROPOSAL.
3. REGULATIONS, TAXES AND PERMITS: THE WHOLE OF THE WORK IS TO BE
EXECUTED IN STRICT ACCORDANCE WITH THE REGULATIONS AND CODES
OF THE GOVERNMENTAL AGENCIES WHOSE JURISDICTION IS APPLICABLE.
GENERAL CONDITIONS:
1. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS &
CONDITIONS. EXISTING DIMENSIONS SHOWN ARE APPROXIMATE AND MUST
BE FIELD VERIFIED.
2. REFER TO SPECIFICATIONS FOR DETAILED DESCRIPTIONS & REQUIREMENTS
OF CONSTRUCTION.
3. GENERAL CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES,
PROVIDE ON-SITE SUPERVISION & BE RESPONSIBLE FOR COMPLIANCE WITH
ALL SAFETY PRECAUTIONS, CODES AND REGULATIONS.
4. PROTECT EXISTING UTILITIES, SITE IMPROVEMENTS & PLANTING TO REMAIN.
5. PATCH ANY SURFACES DAMAGED DURING CONSTRUCTION. SURFACES ARE
TO BE PATCHED FLUSH WITH EXISTING. MATCH EXISTING ADJACENT FINISH
OR APPLY NEW FINISH AS SCHEDULED.
6. PROVIDE SOLID BACKING FOR ALL WALL-MOUNTED ITEMS.
7. IN GENERAL, REPETITIVE DETAILS DRAWN ARE SHOWN IN FULL ONLY ONCE.
REPETITIONS MAY NOT BE COMPLETE IN EVERY DETAIL AS SHOWN IN THE
ORIGINAL DETAIL.
8. DIMENSIONS ARE SHOWN ON THE DRAWINGS. DO NOT SCALE THE
DRAWINGS.
9. ALL HEIGHTS ARE DIMENSIONED FROM THE TOP OF SUBFLOOR UNLESS
NOTED OTHERWISE.
10. WHERE COLUMNS & STUD WALLS ALIGN, GYPSUM BOARD TO BE
CONTINUOUS OVER COLUMNS OR BOXED AROUND COLUMN IF COLUMN
PROJECTS BEYOND WALL.
11. BRING TO THE ATTENTION OF THE C.O. ANY CONDITION OR AREA OF FINISH
THAT IS IN QUESTION OR NOT NOTED.
12. SEAL ALL PENETRATIONS OF WALLS, FLOORS AND CEILINGS WITH A FIRE
RATING EQUIVALENT TO THE CONSTRUCTION PENETRATED AND PER
DETAILS & SPECIFICATIONS.
13. COORDINATE LAYOUT, CLEARANCES, PENETRATIONS, BACKING &
FASTENERS WITH WORK TO FOLLOW.
14. HEATING, PLUMBING AND ELECTRICAL PLANS WHERE SHOWN
DIAGRAMMATICALLY ARE INTENDED TO INDICATE CAPACITY, SIZE, LOCATION
& GENERAL ARRANGEMENTS. ALL NECESSARY FEATURES OF RELATED
CONSTRUCTION WILL BE REQUIRED AS IF SHOWN IN DETAIL.
15. WHERE MECHANICAL & ELECTRICAL EQUIPMENT LOCATIONS CONFLICT
ELECTRICAL, LIGHT FIXTURE LOCATIONS SHALL TAKE PRECEDENCE.
16. PROVIDE SUFFICIENT STUD DEPTH TO CONCEAL MECHANICAL & ELECTRICAL
WORK IN WALLS.
17. PROVIDE ALL NEW MATERIALS (U.N.O.) AND QUALIFIED CRAFT PERSONS TO
COMPLETE THE WORK.
18. CONSTRUCTION DOCUMENTS SHOW THE DESIGN INTENT OF THE PROJECT
AND MAY NOT SHOW MINOR DETAILS OF PROPOSED INSTALLATIONS. THE
INCLUSION OF THESE MINOR DETAILS IS IMPLIED TO PROVIDE A COMPLETE
PROJECT AND ARE TO BE INCLUDED AS A PART OF A BID.
19. REFER TO MECHANICAL & ELECTRICAL DRAWINGS FOR COORDINATION OF
WORK.
20. IN THE CASE OF CONTRADICTIONS BETWEEN DRAWINGS OR BETWEEN
DRAWINGS & SPECIFICATIONS, ASSUME THE MORE COSTLY APPROACH FOR
BIDDING PURPOSES. BRING ALL CONTRADICTIONS TO THE ATTENTION OF
THE C.O..
21. CONTRACTOR SHALL PROMPTLY REMOVE ALL WASTE MATERIALS AND
LEAVE PREMISES AND SITE CLEAN.
22. THE CONTRACTOR SHALL PROVIDE ALL CEILING AND/OR WALL ACCESS
PANELS/DOORS AS REQUIRED BY THE AIR CONDITIONING, PLUMBING &
ELECTRICAL SYSTEMS, PROVIDE APPROVED ASSEMBLIES W/ SELF-CLOSING
DEVICES IN RATED CONSTRUCTION. (PAINT TO MATCH ADJACENT WALL
COLOR)
23. ELECTRICAL OUTLETS AND LIGHTING ARE ONLY SHOWN ON ARCHITECTURAL
"A" SHEETS WHERE PLACEMENT OF SUCH IS CRITICAL TO PARTICULAR
AESTHETICS. SEE ELECTRICAL DRAWINGS FOR ALL ELECTRICAL AND DATA
FEATURES.
DRAWING SET NOTE: THESE DRAWINGS ARE TO BE UTILIZED AS A COMPLETE
SET FOR BIDDING & CONSTRUCTION. INDIVIDUAL SECTIONS OF DRAWINGS
SHOULD NOT BE SEPARATED FROM THE ENTIRE SET. IMPORTANT NOTES FOR
ONE AREA OF WORK MAY BE INCLUDED IN OTHER AREAS IN THE DRAWINGS.
ALL CONTRACTORS & SUPPLIERS MUST REVIEW ENTIRE DRAWING SET &
SPECIFICATIONS.
GENERAL NOTES:
GENERAL WALL NOTES
1. WALL TYPE CONSTRUCTION IS CONTINUOUS FROM SLAB TO ROOF FRAMING
ABOVE UNLESS INDICATED OTHERWISE.
2. IF A WALL TYPE IS NOT INDICATED, PROVIDE WALL TYPE OF MOST SIMILAR
CONDITION - VERIFY WITH C.O..
3. IN CASES OF CONFLICT BETWEEN SECTIONS AND WALL TYPES, CLARIFY WITH
C.O. PRIOR TO BIDDING WHEN TIME ALLOWS, OTHERWISE ASSUME THE MOST
EXPENSIVE CONDITION FOR BIDDING PURPOSES.
4. STRUCTURAL NOTES, SPECIFICATIONS, STUD GAUGE NOTATIONS ETC. TAKE
PRECEDENCE OVER ARCHITECTURAL WALL TYPES.
5. FOR LIGHT GAUGE (NON-STRUCTURAL) METAL FRAMING, PROVIDE MIN. 22
GAUGE STUDS UNLESS THE CONTRACTOR CAN PROVIDE MANUFACTURER'S
DATA SUPPORTING LIGHTER GAUGE STUDS BASED ON HEIGHT AND FINISH
MATERIALS.
6. ALL VOIDS IN EXTERIOR WALLS - INCLUDING IN NON-VISIBLE LOCATIONS - TO BE
FILLED TIGHT WITH INSULATION. SMALL CRACKS & VOIDS TO BE CAULKED OR
SPRAY-FOAMED FOR TIGHT SEAL.
7. ALL EXTERIOR WALLS TO RECEIVE VAPOR BARRIER UNDER INTERIOR FINISH.
ALL SEAMS OF VAPOR BARRIER MUST BE TAPED/SEALED TIGHT AND ALL
JOINTS MUST BE TAPED/ SEALED TIGHT WITH MATERIALS AND METHODS
APPROVED BY VAPOR BARRIER MFR.
8. TYPE "X" GYPSUM WALL BOARD SPECIFIED THROUGHOUT. PROVIDE WATER-
RESISTANT TYPE "X" GYPSUM BOARD ON ENTIRE WALL WHERE PLUMBING
FIXTURES OCCUR. PROVIDE TILE BACKER BOARD TYPE "X" ON ALL WALLS WITH
TILE.
9. WALLS INDICATED WITH ACOUSTICAL INSULATION TO MEET AN STC RATING OF
48 OR MORE, UNLESS OTHERWISE INDICATED.
10. PROVIDE SOUND ATTENUATION INSULATION ON TOP OF ACT WHERE WALLS
TERMINATE AT CEILING OR 6" ABOVE CEILING. EXTEND 5 FEET TO BOTH SIDES
OF WALL. HOLD INSULATION 7" AWAY FROM LIGHT FIXTURES.
11. PROVIDE BACKER ROD & CAULKING JOINT AT ABUTMENT OF ALL DISSIMILAR
MATERIALS.
12. PROVIDE STEEL "J" EDGE METAL AND 1/4" CAULK JOINT AT PERIMETER OF ALL
GYPSUM BOARD WALLS WHERE ABUTTING DIFFERENT MATERIALS.
13. PROVIDE CORNER BEADS AT ALL EXTERNAL GYPSUM BOARD CORNERS.
14. PENETRATIONS OF FIRE-RESISTIVE WALLS, HORIZONTAL ASSEMBLIES SHALL
BE PROTECTED AS REQUIRED IN IBC SECTION 714.
15. PROVIDE FIRE, SMOKE AND CEILING RADIATION DAMPERS AT DUCT
PENETRATIONS AND AIR TRANSFER OPENINGS IN FIRE RATED ASSEMBLIES
PER IBC SECTION 717.
SCALE
BUILDING
SECTIONS
WALL SECTIONS
EXTERIOR
ELEVATION
DETAIL
CALLOUT
INTERIOR
ELEVATION
DOOR NUMBER
WINDOW TYPE
ROOM NAME,
NUMBER, AND AREA
GRID LINES:
LETTERS LEFT TO RIGHT
NUMBERS TOP TO BOTTOM
WALL TYPE
ELEVATION TAG, FLOOR = 100' - 0"
REFERENCE SYMBOLS:
DRAWING
TITLE
STOREFRONT/CURTAINWALL
CALLOUT
TEXT INDICATES
STOREFRONT SYSTEM:
iSF = INTERIOR
STOREFRONT
SF = EXTERIOR
STOREFRONT
CW = CURTAINWALL
FIRE EXTINGUISHER, SEE
CODE PLANS
SHEET
NUMBER
DRAWING
NUMBER
SHEET
NUMBER
DRAWING
NUMBER
SHEET NUMBER
DRAWING
NUMBER
SHEET
NUMBER
DRAWING
NUMBER
SHEET NUMBER
DRAWING NUMBER
FE
WITH
CABINET
WALL-HUNG,
NO CABINET
ROOF TYPE
-SEE ELEVATIONS FOR HEIGHTS
"SIM" INDICATES SIMILAR
CONDITION; SEE NOTES
FLOOR TYPE
A7-14
A3-8
A5-2
VIEW NAME
1/8" = 1'-0"
A
Room name
A
101A
A1-1
A1-1
FA1
Name Elevation
RA
SIM
cw1 i1 e2s
WALL TYPE
WALL HEIGHT
WALL STUD & FINISH HEIGHT
c GWB TO 6" ABOVE CEILING; FRAME OR BRACE TO
STRUCTURE
e EXTERIOR - SEE SECTIONS f FURRING p PARTIAL HEIGHT s TO STRUCTURE x SHAFT - CONTINUOUS THROUGH FLOOR
ASSEMBLIES
WALL TYPE TAG
PROVIDE SIGN AT EACH ROOM ENTRY DOOR AS NOTED AND EACH EXIT AS FOLLOWS:
SIGNAGE NOTES:
1. SEE SPECIFICATIONS FOR SPECIFIC SIGNAGE DETAILS,
DIMENSIONS, FONT, COLORS, MATERIALS, ETC.
2. ALL SIGNAGE INDICATED BELOW SHALL COMPLY WITH
ICC A117.1.
ROOM SIGNAGE
UNISEX
6"
6"
PICTOGRAMS
BRAILLE CHARACTERS
A
UNISEX HC
RESTROOM
5/8" MIN. - 2" MAX. HEIGHT
1/32" RAISED CHARACTERS
UPPERCASE, SANS SERIF ROOM SIGN PANEL TO BE POSTED ADJACENT TO THE
LATCH SIDE OF THE DOOR, 60 INCHES ABOVE THE
FINISH FLOOR TO THE CENTERLINE OF THE SIGN. 18" X
18" CLEAR FLOOR SPACE CENTERED ON TACTILE
CHARACTERS SHALL BE PROVIDED
EXIT
1" TALL, 1/32" RAISED
CHARACTERS, UPPER-
CASE, SAN SERIF
6"
1/
2"
BRAILLE
CHARACTERS
E
EXIT
C
FIRE ALARM
CONTROL
PANEL
FIRE ALARM
CONTROL PANEL
INSIDE
1" TALL
CHARACTERS,
WHITE ON RED
BACKGROUND
3.
EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY
HAVING AN OCCUPANT LOAD OF 50 OR MORE SHALL HAVE
THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A
CONSPICUOUS PLACE, NEAR THE MAIN EXIT.
TYP ACCESSIBLE MOUNTING HEIGHTS
FINISH FLOOR
4'
0"
ANY ACCESSIBLE
DEVICE OR
ACCESSORY
PAPER
TOWEL
DISPENSER
THERMOSTATSWITCH
1'
6"
ELEC.
OUTLET
DIMENSIONS TO TOILET ROOM ACCESSORIES ARE TO THE TOP
OF THE HIGHEST OPENING OR OPERABLE PART.
ACCESSORIES ABOVE COUNTERS SHALL BE MOUNTED WITH T.O.
OPERABLE PARTS LESS THAN 3'-8" A.F.F.
1.
2.
ACCESSIBLE SINK CLEARANCES
DASHED LINE
REPRESENTS
MIN EXTENT OF
CLEAR FLOOR
SPACE
M
IN30
MIN
18"
MIN
48"
17"-25"
R
EF
LE
C
TI
N
G S
U R
FA
C
E
" M
AX
T
O B
.O
M
IN9"
MAX
6"
MIN
11"
MIN
8"
M
IN27
DASHED LINE
REPRESENTS MIN
EXTENT OF
CLEARANCE SIDE ELEVATION PLAN
MIRROR WHERE
OCCURS
FRONT ELEVATION SIDE ELEVATION
CLEAR
FLOOR
SPACE
PLAN
4'
8" M
IN
5' - 0" MIN
6" MAX
36" MIN
MIN
M
IN
1'
3"
"-1
9"33 "-3
6"
16"-18" 7"-9"
M
IN
1/
2"
ACCESSIBLE TOILET
1' - 0" MIN
"-4
1"
M
IN
1'
6"
3' - 4"39" - 41"
4' - 6" MIN
1' - 0" MAX 3' - 6" MIN
ACCESSIBLE URINAL CLEARANCES
CLEAR
FLOOR
SPACE
MIN
30"
M
IN48
SIDE ELEVATION PLAN
M A
X
113 1/2"
MIN
SE
A
T W
A
LL
PROVIDE A SHOWER
SPRAY UNIT WITH
HOSE 60" (MIN) LONG
THAT CAN BE USED
BOTH AS A FIXED
SHOWER HEAD & AS A
HAND HELD UNIT
ACCESSIBLE SHOWER
4' - 0"
MIN
M
IN
3' - 0"
3'
0"
SEAT
1'
6"
18"
VERTICAL
GRAB BAR
18"X32" L-
SHAPED
GRAB BAR
PLAN FRONT ELEVATION
3'
0"
4" M
AX
CONTROL WALL ELEVATION
" M
IN
3" -6
"-3
6"
GRAB BAR
18"X32" L-SHAPED
GRAB BAR
1' - 6"
MAX
15"
CONTROLS AND
HAND SHOWER
LOCATION
" M
IN
" M
AX
CONTROL WALL
1/2" MAX
THRESHOLD
C O
N
TR
O L
W A
LL
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
SHEET OF 42
SHEET SIZE 24x36. WRITTEN
SCALES ARE ACCURATE
PLOTTED 24x36. TEST LINE
BELOW 2" IF PLOTTED FULL
SIZE:
2"
4/
/2
9:
:0
A
M
3/31/2025
A002
GENERAL INFO. & ASSEMBLY &
DOORS
USFS Fort Missoula, Missoula, MT
BUILDING 105 - BAKERY
RENOVATION
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
ACCESSIBLE MOUNTING HEIGHTS AND CLEARANCES
# DATE REVISION
JeffD
C C
B B
D D
A A
100' - 0"
100' - 0"
11' - 0" 7' - 3" 6' - 0" 8' - 6" 3' - 4" 7' - 0"
11' - 0" 7' - 1" 5' - 5" 3' - 6"1' - 11" 7' - 0" 7' - 2"
43' - 1"
8'
0" 8'
0"
5'
7" 5'
8"
8'
1" 8'
1"
5'
6" 5'
3"
8'
0" 8'
1"
43' - 1"
6'
8" 6'
5"
2'
9'
6" 8'
2"
7'
GLASS SHOP
BATHROOM
105 SHOP LAUNDRY
WOOD SHOP
DETAIL WORSPACE
STORAGE
HPT OFFICE
102 10 0a
103A
103B
3a
103C
103D
106A
106B
4a
104A
103E
3b
102A
2a
102B 101A 100A
F.D.
EXISTING
OPENING
EXISTING
OPENING
EXISTING
OPENING
EXISTING
OPENING
EXISTING
OPENING
EXISTING
OPENING
0' 4' 8' 16'
REPAIR DOOR 104a
REPAIR CONCRETE
REPAIR CONCRETE
REPAIR CONCRETE
REPAIR CONCRETE
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
SHEET OF 42
SHEET SIZE 24x36. WRITTEN
SCALES ARE ACCURATE
PLOTTED 24x36. TEST LINE
BELOW 2" IF PLOTTED FULL
SIZE:
2"
4/
/2
9:
:0
A
M
3/31/2025
A003
EXISTING FLOOR PLAN &
PHOTOS
USFS Fort Missoula, Missoula, MT
BUILDING 105 - BAKERY
RENOVATION
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
FLOOR PLAN - EXISTING
NTS
SHOP LAUNDRY - 106
2 NTS
BATHROOM - 105
3 NTS
GLASS SHP - 104
NTS
OFFICE - 102
NTS
STORAGE- 101
NTS
WOOD SHOP - 100
NTS
WOOD SHOP - NORTH - 103
NTS
WOOD SHOP - SOUTH - 103
N N
PLAN
NTS
NORTH ELEVATION
10 NTS
EAST ELEVATION
11 NTS
WEST ELEVATION
13NTS
SOUTH ELEVATION
# DATE REVISION
JeffD
NEW CONSTRUCTION
EXISTING ELEMENTS TO REMAIN
LINEWORK/HATCH LEGEND
ANTICIPATED AREA OF
DISTURBANCE TO BE HYDRO-
SEEDED AFTER CONSTRUCTION.
ALL DISTURBED AREAS TO BE
HYDROSEEDED
C C
B B
D D
A A
NEW OPENING X 7'2' HIGH
8' - 0"
MATCH EXIST.
OPENING HEIGHT
EXPAND OPENING
+/- 6" IN WIDTH FOR
NEW DOOR
EXPAND OPENING
+/- 6" IN WIDTH FOR
NEW DOOR
9 9
DEMOLITION KEYNOTES
NOTE: SEE MECH/ELEC/STRUCT AND CIVIL DRAWINGS FOR ADDITIONAL DEMOLITION
INFORMATION.
REMOVE DOOR OR OPENING CASING, INCLUDING FRAME AND HARDWARE.
SAWCUT & REMOVE PORTION OF WALL NECESSARY TO RECEIVE NEW DOOR AND FRAME.
REMOVE JAMB TRIM. OPENING TO INCLUDE SAWCUT VERTICALLY AT ONE JAMB AND ACROSS
HEAD AS REQUIRED.
SAWCUT AND REMOVE PORTION OF SLAB FOR PLUMBING WORK. COORDINATE W/ PLUMBING
SUBCONTRACTOR. IN ROOM 105, CONTRACTOR TO REMOVE SLAB TO WITHIN 12" OF PERIMETER
WALLS AT A MINIMUM. CONTRACTOR MAY ELECT TO REMOVE ENTIRE SLAB IF THIS CAN BE DONE
WITHOUT DAMAGE TO WALL TILE
DO NOT REMOVE EXISTING CERAMIC TILE FROM EXISTING WALLS. PROTECT DURING OTHER
DEMOLITION
REMOVE LIGHT SWITCH
DEMO CONCRETE PAD
SAWCUT OR DRILL OPENING IN EXISTING WALL FOR DUST COLLECTION DUCTWORK
REMOVE TRANSOM SASH TO ALLOW INSTALL OF MECHANICAL LOUVER. DO NOT DAMAGE SASH,
TURN OVER TO C.O..
GRIND CONCRETE LIP AT DOORWAY
AT NEW WALL OPENING, SAWCUT FLUSH WITH FLOOR, FILL ANY VOIDS WITH CEMENT BASED
FLOOR LEVELER
8" CORE-DRILLED OPENING IN CHIMNEY IN ATTIC SPACE, SEE MECHANICAL PLANS
6" CORE-DRILL THROUGH WALL JUST BELOW CEILING LINE FOR DUST COLLECTION DUCT (4"), COORDINATE WITH DUCT LAYOUT
OPENING IN PLASTER CEILING FOR SUPPLY AND RETURN DIFFUSERS, SEE MECHANICAL.
COORDINATE WITH LIGHTING, DUCTWORK, CONDUIT, AND DUST COLLECTION. NOTE: CEILING
JOIST SPACING IS 16" O.C. EACH OPENING WILL REQUIRE THE REMOVAL OF A SECTION OF JOIST
AND HEADING OFF CUT-JOISTS WITH 2X6 FRAMING
1. VERIFY ALL CONDITIONS AND COORDINATE WITH ALL
DISCIPLINES OF CONTRACT. UNDOCUMENTED FIELD
CHANGES MAY HAVE OCCURRED AND ARE TO BE BROUGHT
TO THE ATTENTION OF THE C.O. WHEN DISCOVERED.
2. SEE CIVIL DRAWINGS FOR SITE DEMOLITION.
3. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS
FOR DEMOLITION WORK OF THOSE TRADES.
4. WHERE DEMOLITION IS INDICATED, WALLS SHALL BE
REMOVED AND CEILING SHALL BE PATCHED, REPAIRED AND
PAINTED TO MATCH EXISTING.
5. CONTRACTOR SHALL MAINTAIN A TEMPORARY WEATHER
TIGHT ENCLOSURE AS ITEMS ARE BEING REMOVED.
6. COORDINATE ALL MECHANICAL, ELECTRICAL, FIRE
SYSTEMS, COMMUNICATIONS AND UTILITY SHUT-DOWNS
WITH OWNER PRIOR TO REMOVING AND OR RELOCATING.
7. DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS
SHOWN ON DRAWINGS. THE INTENT IS TO INDICATE THE
GENERAL SCOPE OF DEMOLITION REQUIRED TO COMPLETE
THE WORK IN ACCORDANCE WITH THE CONTRACT
DRAWINGS.
8. THESE DRAWINGS INDICATE STRUCTURAL AND NON-
STRUCTURAL DEMOLITION THAT IS TO OCCUR TO MAKE
WAY FOR NEW CONSTRUCTION. ADDITIONAL STRUCTURAL
DEMOLITION WORK, CONSTRUCTION OR SHORING
REQUIRING COORDINATION WITH NEW STRUCTURAL IS
INDICATED ON THE STRUCTURAL DRAWINGS.
GENERAL DEMOLITION NOTES
C C
B B
D D
A A
EXISTING
ATTIC ACCESS
ATTIC VENTS;
INFILL OPENING
ABOVE, GRILL
TO REMAIN
ATTIC VENTS;
INFILL OPENING,
KEEP VENT
COVERS
INSTALLED
NEW FAN IN
EXISTING
OPENING
C
B
1 3
D
A
ENLARGE OPENING
BETWEEN EX. FRAMING
TO FIT DROP DOWN
LADDER UNIT
OPENINGS IN
CEILING FOR SUPPLY
AND RETURN DIFFUSERS,
14 TOTAL, SEE MECHANICAL
TYP.
TYP.
NOTE: EXISTING CEILING IS LATH AND PLASTER ON ROUGH-SAWN 2X6 CEILING JOISTS
AT APPROXIMATELY 12'-0" OFF FINISH FLOOR.
OPEN TO STRUCTURE
CEILING LEGEND
GWB 5/8" TYPE "X" GYPSUM
WALLBOARD ON STL. FRAMING -
SEE DETAILS. PAINT P1 UNO
GRILL TO REMAIN, INFILL
3" BEHIND GRILL W/ FRAMING
AND PAINTED GWB
ATTIC HATCH TO BE
ENLARGED AND PULL
DOWN LADDER INSTALLED
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
SHEET OF 42
SHEET SIZE 24x36. WRITTEN
SCALES ARE ACCURATE
PLOTTED 24x36. TEST LINE
BELOW 2" IF PLOTTED FULL
SIZE:
2"
4/
/2
9:
:0
A
M
3/31/2025
A004
DEMOLITION PLANS
USFS Fort Missoula, Missoula, MT
BUILDING 105 - BAKERY
RENOVATION
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
N
1/8" = 1'-0"
DEMOLITION PLAN
21/8" = 1'-0"
EXISTING - REFLECTED CEILING PLAN
NTS
BATHROOM - 105 - DEMO
3 NTS
ATTIC ACCESS
NTS
EXT. DOOR LANDING
5NTS
EXT. CONCRETE APPROACH
N
PLAN
0' 4' 8' 16' 0' 4' 8' 16'
TILE TO REMAIN,
SEE DEMO NOTE
# DATE REVISION
JeffD
1. DETERMINE LOCATION OF ALL UNDERGROUND UTILITIES
PRIOR TO DEMO, EXCAVATION OR PLANTING. MAINTAIN
10' MIN DISTANCE FROM ALL TREES TO UTILITY LINES.
2. PROTECT ALL EXISTING ITEMS/SURFACES TO REMAIN.
EXISTING ELEMENTS DAMAGED DURING CONSTRUCTION
TO BE REPAIRED OR REPLACED BY CONTRACTOR AS
DIRECTED BY THE C.O. AT NO COST TO OWNER.
3. PROTECT EXISTING TREES WITH TEMPORARY
CONSTRUCTION FENCE LOCATED 3 FEET OUTSIDE DRIP
LINE, PROTECT OVERHANGING LIMBS FROM DAMAGE AS
REQUIRED.
GENERAL SITE PLAN NOTES
NEW CONSTRUCTION
EXISTING ELEMENTS TO REMAIN
LINEWORK/HATCH LEGEND
ANTICIPATED AREA OF
DISTURBANCE TO BE HYDRO-
SEEDED AFTER CONSTRUCTION.
ALL DISTURBED AREAS TO BE
HYDROSEEDED
EXISTING
FENCE
EXISTING SHED
EXISTING
SECURE PARKING
BAKERY
EXISTING
OPEN PARKING
POST SIDING ROAD
EX IST IN
G
FEN
C
E
ACCESS
CONTROLL
ED GATE
GATE
CONTRACTOR
ENTRY PATH. AREA
UP TO FENCE DOES
NOT HAVE TO BE
SEEDED UPON
COMPLETION
EXISTNG FENCE
& GATE TO
REMAIN,
TEMPORARILY
REMOVE
FENCE/GATE
AS REQUIRED
FOR NEW WATER
LINE,
REINSTALL
CONTRACTOR
STAGING
PHASE 2
EXISTING
FENCE
BAKERY
PHASE 2
FUTURE
BUILDING
SITE
EXISTING
WATERLINE
NEW HYDRANT
OPTION ITEM 2
EXISTING FENCE TO REMAIN
DELIVERY
& FIRE
ACCESS
EJ
GRAVEL SURFACE
ADA PARKING
SPACE
ANTICIPATED AREAS OF RE-SEEDING,
ALL DISTURBED AREAS TO RECIEVE
NATIVE GRASS HYDROSEED
NEW X-FORMER PAD
BY G.C., COORD. W UTILITY
CONCRETE
SIDEWALK
GRAVEL SUBSTRATE
BITUMINOUS CONCRETE
EXPANSION JOINT @ 8' - 12'
LOCATION ON SITE
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
SHEET OF 42
SHEET SIZE 24x36. WRITTEN
SCALES ARE ACCURATE
PLOTTED 24x36. TEST LINE
BELOW 2" IF PLOTTED FULL
SIZE:
2"
4/
/2
9:
:0
A
M
3/31/2025
A100
SITE PLAN
USFS Fort Missoula, Missoula, MT
BUILDING 105 - BAKERY
RENOVATION
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
PLAN
1" = 50'-0"
SITE PLAN - AREA PLAN
N N
1/16" = 1'-0"
SITE PLAN - ENLARGED
3" = 1'-0"
SIDEWALK EXPANSION JOINT
0' 25' 50' 100'
THIS SITE PLAN IS FOR GENERAL USE ONLY. SEE CIVIL SITE PLAN FOR GRADING, LAYOUT, UTILITIES, AND OTHER DETAILED
CONSTRUCTION INFORMATION.
0' 8' 16' 32'
# DATE REVISION
OPTION ITEM 5
OPTION ITEM 6
(SEE OPTION
ITEM 7)
JeffD
C C
B B
D D
A A
A201
A2012 A201 4
A201
100' - 0"
11' - 0" 7' - 3" 6' - 0" 8' - 6" 3' - 4" 7' - 0" 16' - 0" 3' - 7" 3' - 0" 7' - 5"
43' - 1"
43' - 1" 30' - 0"
6'
8" 6'
5"
2'
9'
6" 8'
2"
7'
OPENING
10' x 7'-2"
EXISTING FLOOR TO REMAIN
SEE EQUIPMENT
PLAN FOR ADD'L
INFO.
103A
103B
103C
103D
106A
106B
104A
103E
102A
102B 101A 100A i2 verify w shower
1584 SF
WOOD SHOP - 103
171 SF
HPT OFFICE - 102
76 SF
STORAGE - 101
143 SF
SHOP LAUNDRY - 106
183 SF
GLASS SHOP - 104
107 SF
BATHROOM - 105
A802
A802 i2 i1 i2
DUST COLLECTOR
ROOF OVERHANG
1'
5" 8'
7"
8'
7" 5'
5"
15' - 0"2' - 0"
2'
0"
0"
106a
103b
103a
102a
102b
100a
104a
A501
Sim
A501
Sim
A501
Sim
A501
Sim
A501
Sim
198 SF
SHOP - 100
A202
A301
A301
A301
A301
SELF-LEVELING
FLOOR FILL, SEE
FINISH PLAN
AIR COMPRESSOR
BY OWNER, PIPING
INCLUDED IN OPTION
ITEM #3
SLAB & STRUCTURE
OPTION ITEM 1
BASE BID
SLAB
NEW PAD MTD.
TRANSFORMER. 6" CONC.
PAD +/- 6'X'6' BY G.C.,
COORD. SIZE WITH UTILITY.
FIELD VERIFY FINAL
LOCATION.
MODIFY DOWNSPOUT
TO KICK SOUTH, MOVE
SPLASHBLOCK
1. JAMB THICKNESS TO BE SITE VERIFIED
2. EXISTING EXTERIOR DOORS & WINDOWS TO REMAIN WILL BE INSPECTED AND
RESTORED IF NECESSARY.
3. DOOR & WINDOW JAMBS TO BE EXTENDED WHERE FURRED WALLS HAVE BEEN
ADDED.
GENERAL DOOR & WINDOW NOTES
1. DIMENSIONS ARE TO FACE OF STUD, EXISTING WALL FINISH, MASONRY, OR DOOR/WINDOW
OPENINGS. DIMENSIONS OF EXISTING CONSTRUCTION ARE ESTIMATED - VERIFY
DIMENSIONS OF ALL EXISTING CONSTRUCTION IN THE FIELD. DIMENSIONS TO OPENINGS
ARE NOMINAL. VERIFY ALL OPENINGS WITH ROUGH OPENING REQUIREMENTS.
2. EXISTING CONSTRUCTION TO REMAIN SHOWN GREY, NEW CONSTRUCTION SHOWN BLACK.
3. VERIFY EXISTING WALL CONSTRUCTION AND THICKNESSS FOR DOOR INSTALLATION
4. ALL EGRESS DOORS SHALL BE READILY OPERABLE FROM THE EGRESS SIDE WITHOUT THE
USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.
5. EXISTING CONCRETE FLOORS TO BE REPAIRED WHERE CRACKS HAVE FORMED. SEE
FINISH PLAN.
GENERAL FLOOR PLAN NOTES
NOTE: SEE ELEVATIONS AND FINISH
SCHEDULES FOR WALL FINISHES, TYPICAL
ALL WALL TYPES
5/8" GYPSUM
BOARD TYPE X
3" "NAILSTRIP" RIGID
INSULATION W
NAILERS
INTERIOR WALL TYPES
INTERIOR FURRED PARTITION
NON-RATED
2X4 WD
STUDS @ 16"
O.C.
5/8" GYPSUM
BOARD TYPE X
5/8" GYPSUM
BOARD TYPE X
2X6 WD STUDS
@ 16" OC
5/8" GYPSUM
BOARD TYPE X
INTERIOR PARTITIONINTERIOR PARTITION
NON-RATEDNON-RATED
i3i2i1
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
SHEET OF 42
SHEET SIZE 24x36. WRITTEN
SCALES ARE ACCURATE
PLOTTED 24x36. TEST LINE
BELOW 2" IF PLOTTED FULL
SIZE:
2"
4/
/2
9:
:1
A
M
3/31/2025
A101
FLOOR PLAN & SCHEDULES
USFS Fort Missoula, Missoula, MT
BUILDING 105 - BAKERY
RENOVATION
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
EXISTING WINDOW SCHEDULE
Mark Width Height Comments
100A 3' - 1 1/4" 5' - 7 1/2" EXISTING - NO WORK
100B 2' - 11" 1' - 8" EXISTING - NO WORK
101A 2' - 6" 3' - 0" EXISTING - NO WORK
102A 3' - 1 1/4" 5' - 7 1/2" ADD JAMB EXTENSION FOR NEW FURRED WALL
102B 2' - 11 1/4" 3' - 0" ADD JAMB EXTENSION FOR NEW FURRED WALL
102C 4' - 11" 1' - 8" EXISTING - NO WORK
103A 3' - 1 1/4" 5' - 7 1/2" EXISTING - NO WORK
103B 3' - 1 1/4" 5' - 7 1/2" EXISTING - NO WORK
103C 3' - 1 1/4" 5' - 7 1/2" EXISTING - NO WORK
103D 3' - 1 1/4" 5' - 7 1/2" EXISTING - NO WORK
103E 2' - 11 1/4" 3' - 0" EXISTING - NO WORK
103F 4' - 11" 1' - 8" Remove sash, frame to remain. Install mechanical louver
103G 4' - 11" 1' - 8" EXISTING - NO WORK
104A 2' - 11 1/4" 3' - 0" EXISTING - NO WORK
106A 2' - 11 1/4" 3' - 0" EXISTING - NO WORK
106B 2' - 11 1/4" 3' - 0" EXISTING - NO WORK
106C 2' - 11" 1' - 8" EXISTING - NO WORK
1/4" = 1'-0"
FLOOR PLAN
N N
PLAN
# DATE REVISION
JeffD
INTERIOR EXTERIOR
SET IN MASTIC BED
CONCRETE FASTENER
BACKER ROD W/ SEALANT
8" DUST COLLECTION DUCT
ROUND METAL COLLAR
SET IN SEALANT
PACKED INSULATION
ROUND METAL COLLAR
SET IN SEALANT
C C
B B
D D
A A
EXISTING ROOF TO
REMAIN
A102
5 1/2" / 1'-0"5 1/2" / 1'-0"
A301
A301
A301
A301
EXISTING
VENTING TO
REMAIN
RUN NEW PLUMBING
VENT THROUGH CENTER OF
EXISTING EXHAUST CAP A202
C
B
1 3
D
A
CRITICAL NOTE: PROTECT
ROOF AND GUTTERS DURING
ALL CHIMNEY AND ROOF-TOP
MECHANICAL WORK
2" AIR GAP
[NEW]INSULATION BAFFLE, RUN 48"
FROM EAVE, MINIMUM
BAFFLE SPACER TAB
[NEW] BLOWN-IN INSULATION
DISTANCE
4' BAFFLE
[EXIST] CLAY ROOF TILE
[EXIST] BATTEN
[EXIST] ROOF PURLIN
(EXIST) GUTTER
[EXIST] EAVE TRIM
[EXIST] BLOCKING
[EXISTING WALL ASSEMBLY]
NOTE: VENT BAFFLES DO
NOT CONNECT TO EAVE VENTS.
VENTILATION IS THROUGH GAPS
IN SHEATHING AND CLAY TILES
BAFFLES ARE TO PROVIDE GAP
FROM SHEATHING TO INSULATION
ADD TRIM BLOCK AT VENTS FOR
FLUSH VENT MOUNTING
EXHAUST VENTS, SEE MECH.
EXHAUST VENT,
SEE MECH.
1. THIS PROJECT DOES NOT INCLUDE ANY SPECIFIC ROOFING WORK. THE
EXISTING CLAY TILE ROOF TO REMAIN.
2. GUTTERS AND DOWNSPOUTS TO REMAIN. MODIFY ONE DOWNSPOUT AS
INDICATED TO CHANGE KICK-OUT TO NOT DRAIN ONTO CONCRETE.
3. SOME WORK, INCLUDING CHIMNEY CAPS AND VENTS, WILL REQUIRE
ROOF ACCESS. EXISTING ROOF TILES MUST BE PROTECTED BY RIGID
INSULATION PANELS WHEN EVER CONSTRUCTION PERSONNEL ACCESS
THE ROOF.
DRAWING SET NOTE: THESE DRAWINGS ARE TO BE UTILIZED AS A
COMPLETE SET FOR BIDDING & CONSTRUCTION. INDIVIDUAL SECTIONS OF
DRAWINGS SHOULD NOT BE SEPARATED FROM THE ENTIRE SET.
IMPORTANT NOTES FOR ONE AREA OF WORK MAY BE INCLUDED IN OTHER
AREAS IN THE DRAWINGS. ALL CONTRACTORS & SUPPLIERS MUST REVIEW
ENTIRE DRAWING SET & SPECIFICATIONS.
ROOF NOTES:
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
SHEET OF 42
SHEET SIZE 24x36. WRITTEN
SCALES ARE ACCURATE
PLOTTED 24x36. TEST LINE
BELOW 2" IF PLOTTED FULL
SIZE:
2"
4/
/2
9:
:1
A
M
3/31/2025
A102
ROOF PLAN & EXT. DETAILS
USFS Fort Missoula, Missoula, MT
BUILDING 105 - BAKERY
RENOVATION
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
EXT. CHIMNEY - NORTH
EXT. CHIMNEY- WEST
FILL ANY CRACKS ALONG TOP
EDGE OF CHIMNEYS, ADD
SLOPED GROUT TOP TO
CHIMNEY, PAINT WHITE
• PREP SURFACE/ROUGH
• PRIME SURFACE
• APPLY GROUT
• TOOL/GRIND FLUSH WITH
CHIMNEY SURFACE
• PAINT
3" = 1'-0"
DUST DUCT @ WALL
ROOF PLAN
4 N N
PLAN
1" = 1'-0"
EAVE DETAIL
0' 4' 8' 16'
1 1/2" = 1'-0"
ROOF NOTES
# DATE REVISION
JeffD
F
C C
B B
D D
A A
C
B
1 3
D
A
NEW PULL
DOWN LADDER
A103
LIGHT FIXTURE,
TYP. HANG BELOW
DUCTWORK.
SURFACE
MTD.
AS PER MFR.
FIELD VERIFY WIDTH OF THE STAIR TO FIT
OPENING WIDTH. OPENING LENGTH TO BE
INCREASED TO FIT LADDER UNIT. BRACE AND
MODIFY OPENING IN TRUSS AS PER MFR.
ATTIC STAIR
MOUNTING
FLANGE
STEEL FOLDING LADDER UNIT:
RAINBOW F-SERIES, 22.5" WIDE X
REQUIRED HEIGHT.
EXISTING 2X6
NEW 2X8
HINGE END
OF LADDER
(2) 2X8 HEADER
AT HINGE
PAINTED PLYWOOD
COVER
RIGID INSULATION
INTEGRAL STEEL TRIM
+/- 12'
FIELD VERIFY
TRUSS BOTTOM
CHORD
+/- 12'
FIELD VERIFY
EXISTING FRAMING LAYOUT
2X6 CEILING FRAMING TYP.
REVISED FRAMING
(2) 2X8
NEW 2X8 EA.
SIDE
A34 CLIP @ EA.
EXISTING 2X
JOIST HANGER
TYP.
(2) 2X8 HANGER,
REMOVE EX. BLOCKING
AS REQUIRED
(2) 2X8 NAIL TO
EXISTING
A103
EXISTING GRILL,
PAINT WHITE
NEW NAILER
GYP BD, PAINT BLACK
EXISTING OPENING FRAMING
NEW INSULATION
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
SHEET OF 42
SHEET SIZE 24x36. WRITTEN
SCALES ARE ACCURATE
PLOTTED 24x36. TEST LINE
BELOW 2" IF PLOTTED FULL
SIZE:
2"
4/
/2
9:
:1
A
M
3/31/2025
A103
REFLECTED CEILING PLAN
USFS Fort Missoula, Missoula, MT
BUILDING 105 - BAKERY
RENOVATION
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
1/4" = 1'-0"
REFLECTED CEILING PLAN
3" = 1'-0"
ATTIC LADDER
1/2" = 1'-0"
ATTIC LADDER PLAN
3" = 1'-0"
CEILING VENT INFILL
# DATE REVISION
JeffD
F
F
F
F
SD
D D
T
DUST COLLECTION
COMPRESSOR, BY
OWNER
G
LA
SS
C
U
TT
E R
S
F
ST
O R
A G
E -1
WALL OPENING
SLIDER
TB
D O
O R
R A
C K
SA
SH
R A
C K
ST
O
R
LU
M
BE
R
R A
C K
C
O
VE
R
ED
0'4'8'16'
DDT
BS
SH 1
PSW
SH 4
SH 2
BSW 2
JN
PL
R 1
DP
GR GR
MM1
MM2
171 SF
HPT OFFICE - 102
1584 SF
WOOD SHOP - 103
183 SF
GLASS SHOP - 104
107 SF
BATHROOM - 105
143 SF
SHOP LAUNDRY - 106
COVERED
STORAGE,
OPTION ITEM
EAVE-PROTECTED
STORAGE
DELIVERY TO SHOP
CS 1
SH 3
L 1
TB 1
TS-1
TS 2
DS
BSW 1
SSW
CLAMP
S ETC.
TB 1
STORAGE
RACKS, BY OWNER
OPTION ITEM: EQUIPMENT RELOCATION
RELOCATION OF THE WOODWORKING EQUIPMENT FROM THE EXISTING SHOP FACILITY LOCATED AT 1600 CATLIN STREET, MISSOULA, APPROXIMATELY 2.6 MILES FROM THE PROJECT SITE IS OPTION ITEM #4
OPTION ITEM TO INCLUDE:
• LOADING EQUIPMENT FROM EXISTING SHOP ONTO TRANSPORTATION EQUIPMENT
• MOVING EQUIPMENT INTO THE THE BAKERY BUILDING
• SETTING THE EQUIPMENT IN IT'S FINAL LOCATION AT THE DIRECTION OF USFS HISTORIC PRESERVATION STAFF
• HOOKING UP POWER AND DUST COLLECTION TO EQUIPMENT ONCE PLACED
• EQUIPMENT TO BE MOVED IS INCLUDED IN THE SPECIFICATIONS
NOT INCLUDED IN THE OPTION ITEM: MOVING OR SET UP OF OWNER-CONSTRUCTED CUSTOM RUN-OUT TABLES FOR TABLE SAWS, OWNER-PROVIDED BASE CABINET AND RUN OUT TABLES FOR MITER SAW, OR OTHER OWNER PROVIDED EQUIPMENT ACCESSORIES. THE OWNER WILL MOVE AND SET UP THESE ITEMS IN COORDINATION WITH THE CONTRACTOR.
TABLE SAWS
CUSTOM RUN-OUT
TABLES TO BE
MOVED BY OWNER
SHAPER 1 PLANER JOINER
LATHESHAPER 4, 2 & 3 SIMILARLOBO - TENONER/MORTISE COMBO
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
SHEET OF 42
SHEET SIZE 24x36. WRITTEN
SCALES ARE ACCURATE
PLOTTED 24x36. TEST LINE
BELOW 2" IF PLOTTED FULL
SIZE:
2"
4/
/2
9:
:1
A
M
3/31/2025
A104
EQUIPMENT PLAN
USFS Fort Missoula, Missoula, MT
BUILDING 105 - BAKERY
RENOVATION
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
1/4" = 1'-0"
EQUIPMENT PLAN
Equipment Schedule Type Mark Type Comments Dust Collection Use Pattern
BS BELT SANDER Medium Occasional, Low duration
BSW 1 BAND SAW Low Occasional, Low duration
BSW 2 BAND SAW Medium Occasional, Long duration
CS 1 CHOP SAW Medium Occasional, Short duration
DP DRILL PRESS none
DS DRUM SANDER High Occasional, Long duration
GR BENCH GRINDER none
GR BENCH GRINDER none
JN JOINER High Occasional, Long duration
L 1 LATHE Low Infrequent
LST LOBO TENONER Very High Infrequent, this machine has 4 dust outputs
MM1 MORTISE MACHINE Low Occasional, Short duration
MM2 MORTISE MACHINE Low Occasional, Short duration
PL PLANER High Frequent, long duration - production
PSW PANEL SAW Medium Occasional, Short duration
R 1 ROUTER Medium Occasional, medium duration
SH 1 SHAPER High Frequent, long duration with power feed
SH 2 SHAPER - SMALL Medium Occasional, long duration
SH 3 SHAPER - SMALL Medium
SH 4 SHAPER - Med High Occassionl, long duration with power feed
SSW SCROLL SAW Low Infrequent
TN TENONER Low Infrequent, short duration
TS 2 TABLE SAW High Frequent, long duration - production
TS-1 TABLE SAW High Frequent, long duration - production
NN
ALL EQUIPMENT SHOWN ON THIS PLAN IS TO BE SUPPLIED
AND PLACED BY THE OWNER.
1/4" = 1'-0"
EQUIPMENT PHOTOS
# DATE REVISION
JeffD
NEW CONSTRUCTION
EXISTING ELEMENTS TO REMAIN
LINEWORK/HATCH LEGEND
ANTICIPATED AREA OF
DISTURBANCE TO BE HYDRO-
SEEDED AFTER CONSTRUCTION.
ALL DISTURBED AREAS TO BE
HYDROSEEDED
1. THIS LEGEND DOES NOT INCLUDE ALL
MATERIALS. SEE NOTES AND REFERENCED
DETAILS FOR ADDITIONAL INFORMATION.
2. ALL EXPOSED WOOD & FIBER CEMENT TO
BE PAINTED.
3. PAINT ALL WINDOW TRIM, WD SOFFITS &
ROOF FASCIAS COLOR P11.
NOTES
MATERIALS LEGEND
COMPOSITE ROOF SHINGLES
CAST IN PLACE CONCRETE
Level 1
100' - 0"
Level 2
112' - 0"
2 13
100A 101A 102B
A301
Level 1
100' - 0"
Level 2
112' - 0"
C BD A
100B103D 103C 103G
103a
103B 103A
100a
A301
MODIFY DOWNSPOUT
TO KICK SOUTH, RELOCATE
SPLASH BLOCK
Level 1
100' - 0"
Level 2
112' - 0"
CB DA
102C 103F
102a
102A
103b 103E 104A
A301
REMOVE SASH,
INSTALL LOUVER
CRACK REPAIR &
GROUT CAP,
SEE DETAIL
INTAKE, SEE MECH
BOOT
INTAKE, SEE MECH
CRACK REPAIR &
GROUT CAP,
SEE DETAIL
PAINT CHIMNEY
WHITE
PAINT CHIMNEY - WHITECRITICAL NOTE: PROTECT
ROOF AND GUTTERS DURING
ALL CHIMNEY AND ROOF-TOP
MECHANICAL WORK
Level 1
100' - 0"
Level 2
112' - 0"
21 3
106C 106B
104a
A301
CRACK REPAIR
PAINT CHIMNEYS
WHITE
GRUOT CAP
MODIFY DOWNSPOUT
TO KICK SOUTH, MOVE
SPLASHBLOCK
DATE:
SHEET:
317 N. Cruse Ave. Suite 201 Helena, Montana 59601
406.449.2013 www.mosaicarch.com
D A
TE
S
TA
M
P a r c h i t e c t u r e - p l a n n i n g - d e s i g n
SHEET OF 42
SHEET SIZE 24x36. WRITTEN
SCALES ARE ACCURATE
PLOTTED 24x36. TEST LINE
BELOW 2" IF PLOTTED FULL
SIZE:
2"
4/
/2
9:
:2
A
M
3/31/2025
A201
EXTERIOR ELEVATIONS
USFS Fort Missoula, Missoula, MT
BUILDING 105 - BAKERY
RENOVATION
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
1/8" = 1'-0"
NORTH ELEVATION
1 1/8" = 1'-0"
EAST ELEVATION
1/8" = 1'-0"
WEST ELEVATION
41/8" = 1'-0"
SOUTH ELEVATION
EXISTING WINDOW SCHEDULE
Mark Width Height Comments
100A 3' - 1 1/4" 5' - 7 1/2" EXISTING - NO WORK
100B 2' - 11" 1' - 8" EXISTING - NO WORK
101A 2' - 6" 3' - 0" EXISTING - NO WORK
102A 3' - 1 1/4" 5' - 7 1/2" ADD JAMB EXTENSION FOR NEW FURRED WALL
102B 2' - 11 1/4" 3' - 0" ADD JAMB EXTENSION FOR NEW FURRED WALL
102C 4' - 11" 1' - 8" EXISTING - NO WORK
103A 3' - 1 1/4" 5' - 7 1/2" EXISTING - NO WORK
103B 3' - 1 1/4" 5' - 7 1/2" EXISTING - NO WORK
103C 3' - 1 1/4" 5' - 7 1/2" EXISTING - NO WORK
103D 3' - 1 1/4" 5' - 7 1/2" EXISTING - NO WORK
103E 2' - 11 1/4" 3' - 0" EXISTING - NO WORK
103F 4' - 11" 1' - 8" Remove sash, frame to remain. Install mechanical louver
103G 4' - 11" 1' - 8" EXISTING - NO WORK
104A 2' - 11 1/4" 3' - 0" EXISTING - NO WORK
106A 2' - 11 1/4" 3' - 0" EXISTING - NO WORK
106B 2' - 11 1/4" 3' - 0" EXISTING - NO WORK
106C 2' - 11" 1' - 8" EXISTING - NO WORK
# DATE REVISION
JeffD
D D
A202
A2024
ROOF OUTLINE ABOVE
1'
5"
14' - 0"
7' - 5"3' - 0"3' - 7"
4x6x3/16
T.S. POSTS
1'
5"
8'
7" 8'
7"
1'
5"
6' - 0"
12" THICK
SLAB
C C
D D
5 1/2" / 1'-0"
12' - 8"
Level 1
100' - 0"
3' - 0"
A202
A202
Sim
A202
Sim
A202
Sim6' -
3"
2' - 1"
5 1/2" / 1'-0"
4x6x 3/16" T.S.
TRUSS
3' - 0"
Level 1
100' - 0"
D
1' - 5" 1' - 5"
20' - 0"
A202
Sim
LUMBER RACKS
BY OWNER
1/2" THRU BOLTS
4"x 6" x 1/4" HSS
3/8" STEEL PLATE, 4" X 18"
WELDED CONNECTION ALL SIDES
4"x 6"x 1/4" HSS COLUMN
1' - 6"
2" 5"
12" CONCRETE
THICKENED SLAB
(4) 1/2" x 10" ANCHOR
BOLTS W/ LEVELING
NUT - AT 1 1/2" FROM
CORNER OF PLATE
NON-SHRINK MORTAR
GRAVEL
SUBSTRATE
9" x 13" x 3/8" BASE PLATE
WELDED CONNECTION
2 1/2" 6" 2 1/2"
1 1/2"
MET…