Attachment 5 Chronic Dialysis Sleep Program Drawings Part 2.pdf
PDF 18 MB Posted
- Attached to
- Y1DA--Construct Dialysis and Sleep Program Construct and Renovate Chronic Dialysis & Sleep Program Project #612 502 Minor Construction - Martinez, CA VISN 21 Federal contract opportunity
- Solicitation number
- 36E77620R0039
About this file
This document provides details for a federal contract opportunity to construct and renovate chronic dialysis and sleep program spaces at the Martinez VA Outpatient Clinic in Martinez, California. The project includes constructing a 6,000 square foot addition to Building 20 for administration, dialysis, and sleep lab spaces; renovating 4,200 square feet of Building 20 for pharmacy, administration, canteen, and retail areas; adding a 1,000 square foot coffee bar to Building 19; and installing dialysis boxes in patient rooms in Building 20. The solicitation will be issued as a request for proposal on July 24, 2020 for a service-disabled veteran-owned small business set-aside. The period of performance is approximately 760 calendar days from notice to proceed. The magnitude of construction is expected to exceed $10 million. Questions must be submitted in writing by the specified due date.
View the file
Other files for this federal contract opportunity
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F.E.C.
F .E
.C
F.E.C.
SLEEP ROOM 3
G115
SLEEP ROOM 4
G116
PRINT/COPY
C410A
TOILET 4
G116A
TOILET 2
G117A
CORRIDOR 4
C410
CONTROL ROOM
G114
TOILET 3
G115A
TOILET 1
G113A
SLEEP ROOM 1
G113
SLEEP ROOM 2
G117TOILET 2
G118
DIALYSIS
EQUIPMENT
G119
TOILET 1
G112STERILE
EQUIPMENT
G111
NEPHRO - LOGIST
G110
CORRIDOR 2
C409
CONFERENCE
G109
OPEN OFFICE
G100
E L
E C
T R
IC
A
L R
O O
M
G
CONSULT
G107CHIEF
G106
TELECOM
G105
SUPV
G104
SUPV
G103
AE400B
AE400B4
AE400B 3
1 2 3 4 6 7
C
E
F
G
12' - 2" 14' - 4" 1' - 0" 9' - 11" 9' - 11" 12' - 6" 19' - 8" 7' - 8" 5' - 8" 17' - 2" 12' - 2" 1' - 0" 7' - 5" 7' - 1" 13' - 4"
SUPV
G102
UTILITY CLOSET
G111A
CORRIDOR 3
C408
CORRIDOR 1
C411
1611 12
A
A A
A
A
A
A
A
A A
A
A
B
B
B
B B
D
AE500B
AE500B
2.9
B
A
3.5 6.3 6.4
B.8
C.8
D
F.8
4.7
6 7
AE503
AE503
8.1 9 10
151' - 0"
AE400B
AE504
8 8.5
5.113
151515
AE500.1B
AE500.1B
AE500.1B
12' - 2" 16' - 4" 94' - 8" 16' - 6" 13' - 4"
153' - 0"
3' - 10" 4
7' - 0"
7' - 2" 36' - 5" 3' - 0" 17' - 6" 13' - 2" 16' - 6" 13' - 4"
53' - 1"
10 10
5 1. CONTRACTOR SHALL FIELD VERIFY EXISTING DIMENSIONS AND
CONDITIONS BEFORE STARTING WORK.
2. WHEN LAYING OUT WALLS, CONTRACTOR SHALL TAKE FIELD
MEASUREMENTS TO ENSURE ALL REQUIRED CLEAR DIMENSIONS
ARE MAINTAINED AS INDICATED.
3. PENETRATIONS ARE NOT PERMITTED THROUGH STRUCTURAL
MEMBERS.
4. ALL EXPOSED WALL OUTSIDE CORNERS SHALL RECEIVE
CORNER GUARDS, PER PLAN.
5. WHERE FULL HEIGHT WALLS ARE SHOWN, FRAME WALL TO FORM
A TIGHT FIT AROUND EXISTING DUCT OR PIPING; SEAL ALL GAPS
AND CAULK ALL AROUND TO MAINTAIN INTEGRITY OF RATED
WALL WHERE APPLICABLE.
6. WHERE NEW DUCTS OR PIPING PENETRATE FULL HEIGHT
WALLS; SEAL ALL GAPS AND FIRE CAULK ALL AROUND TO
MAINTAIN INTEGRITY OF RATED WALL WHERE APPLICABLE.
7. IN ALL AREAS WITH DEPRESSED SLAB, FILL WITH CONCRETE
TOPPING PRIOR TO INSTALLING FLOOR FINISH.
8. ALL WALLS SHALL BE 4" METAL STUD WALLS, EXCEPT AT
EXTERIOR WALLS AND RECESSED FEC LOCATIONS PROVIDE 6"
METAL STUDS.
GENERAL NOTES
SYMBOL
1-HOUR FIRE RATED PARTITION
SMOKE PARTITION
SOUND RATED PARTITION
FULL HEIGHT PARTITION
CEILING HEIGHT PARTITION
CORNER GUARD/END WALL GUARD
HANDRAIL/WALL GUARD COMBINATION
CHAIR RAIL
FULLY RECESSED FIRE EXTINGUISHER
CABINET
MODULAR WALL PARTITIONS
SOUND TRANSMISSION COEFFICIENT
RATING
LEGEND
CG
EG
FEC
STC
SHEET NOTES
RETRACTABLE PARTITION
ROOF ACCESS LADDER
ROOF HATCH
SHELF AT BRACE
EMPTY GAS CYLINDER RACK - UNDER COUNTER
REFRIGERATOR SPACE, VERIFY SIZE PRIOR TO FABRICATING
CABINETS
BASE AND UPPER CABINETS
BABY CHANGING STATION
GAS CYLINDER RACK
PROVIDE BLACKOUT SHADES TYPICAL AT ALL SLEEP ROOMS
3" EXPANSION JOINT
PROVIDE 3/4" F.T. PLYWOOD WALL SHEATHING OVER GYPSUM
BOARD. INSTALL TO 8'-0" ABOVE F.F. PAINT TO MATCH FIELD
COLOR.
CHAIR RAIL
HAND RAIL
SEISMIC JOINT COVER
WALL MOUNTED TV. AT + 72" A.F.F. PROVIDE METAL BACKING
PLATES AS NECESSARY FOR COMPLETE INSTALLATION
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C T
PROJECT
NORTH
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of
VA MARTINEZ CAMPUS , CA
19 & 20K. F. DAVIS ENGINEERING INC.
530 LA GONDA WAY, SUITE E
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
KEY PLAN
B
BUILDING 19
BUILDING 20
02/25/2020
2/24/2020 3:25:53 PMH:\REVIT USER FILES\2018\CHRONIC DIALYSIS FINAL STAMPED SUBMITTAL - REV 2 - V2018_RonKorte1120.rvt
CHRONIC DIALYSIS AND
SLEEP PROGRAM
I. VALDOV
AE102B
ARCHITECTURAL FLOOR PLAN -
ADDITION B
J.ROBERTS
612-502
I. VALDOV
1/8" = 1'-0"AE102B
1 ADDITION B FLOOR PLAN
M A
T C
H L
IN
E M
A T
C H
L
IN
E
PROJECT
NORTH
1 FURNITURE PLAN 9/9/2019
2 CLIENT COMMENTS 1/28/2020
.E
.C
1 2 3 4 6
C
E
F
G
148 SF
DIALYSIS
EQUIPMENT
113 SF
NEPHRO - LOGIST
G110
355 SF
CORRIDOR 2
C409
454 SF
CONFERENCE
G109
1130 SF
OPEN OFFICE
G100
111 SF
ELECTRICAL
ROOM
G108
140 SF
CONSULT
G107
127 SF
CHIEF
G106
109 SF
TELECOM
G105
111 SF
SUPV
G104
107 SF
SUPV
G103
12' - 2" 14' - 4" 1' - 0" 19' - 10" 12' - 6" 19' - 8" 7' - 8"
103 SF
SUPV
G102
282 SF
CORRIDOR 3
C408
212 SF
CORRIDOR 1
C411
AE500B
AE500B
2.9
B
A
3.5 6.3
B.8
C.8
D
F.8
4.7
AE503
AE400B
AE500.1B
AE500.1B
11' - 1" 9' - 10"
4' - 3"
9' - 6" 9' - 4" 9' - 0" 8' - 8"
ALIGN
ALIGN
ALIGN
5' - 3"
1' - 4"
7' - 11"
1. CONTRACTOR SHALL FIELD VERIFY EXISTING DIMENSIONS AND
CONDITIONS BEFORE STARTING WORK.
2. WHEN LAYING OUT WALLS, CONTRACTOR SHALL TAKE FIELD
MEASUREMENTS TO ENSURE ALL REQUIRED CLEAR DIMENSIONS
ARE MAINTAINED AS INDICATED.
3. PENETRATIONS ARE NOT PERMITTED THROUGH STRUCTURAL
MEMBERS.
4. ALL EXPOSED WALL OUTSIDE CORNERS SHALL RECEIVE
CORNER GUARDS, PER PLAN.
5. WHERE FULL HEIGHT WALLS ARE SHOWN, FRAME WALL TO FORM
A TIGHT FIT AROUND EXISTING DUCT OR PIPING; SEAL ALL GAPS
AND CAULK ALL AROUND TO MAINTAIN INTEGRITY OF RATED
WALL WHERE APPLICABLE.
6. WHERE NEW DUCTS OR PIPING PENETRATE FULL HEIGHT
WALLS; SEAL ALL GAPS AND FIRE CAULK ALL AROUND TO
MAINTAIN INTEGRITY OF RATED WALL WHERE APPLICABLE.
7. IN ALL AREAS WITH DEPRESSED SLAB, FILL WITH CONCRETE
TOPPING PRIOR TO INSTALLING FLOOR FINISH.
8. ALL WALLS SHALL BE 4" METAL STUD WALLS, EXCEPT AT
EXTERIOR WALLS AND RECESSED FEC LOCATIONS PROVIDE 6"
METAL STUDS.
GENERAL NOTES
LEGEND
2-HOUR FIRE RATED PARTITION)
1-HOUR FIRE RATED PARTITION
SMOKE PARTITION
V V ITEM - VA SUPPLIED & INSTALLED
VC ITEM - VA SUPPLIED & CONTRACTOR
INSTALLED
SOUND RATED PARTITION
FULL HEIGHT PARTITION
CEILING HEIGHT PARTITION
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C T
PROJECT
NORTH
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of
VA MARTINEZ CAMPUS , CA
19 & 20K. F. DAVIS ENGINEERING INC.
530 LA GONDA WAY, SUITE E
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
KEY PLAN
B
BUILDING 19
BUILDING 20
02/25/2020
2/24/2020 3:25:42 PMH:\REVIT USER FILES\2018\CHRONIC DIALYSIS FINAL STAMPED SUBMITTAL - REV 2 - V2018_RonKorte1120.rvt
CHRONIC DIALYSIS AND
SLEEP PROGRAM
D.DIMAT
AE102.1B
ARCHITECTURAL ENLARGED PLAN
WEST - ADDITION B
J.ROBERTS
612-502
D.DIMAT
1/4" = 1'-0"AE102.1B
1 ADDITION B ENLARGED PLAN WEST
M A
T C
H L
IN
E
S E
E A
S B
M A
T C
H L
IN
E
S E
E A
S B
PROJECT
NORTH
SHEET NOTES
F.E.C. F.E.C.
AE400B4
6 7
C
E
F
G
200 SF
SLEEP ROOM 3
G115
200 SF
SLEEP ROOM 4
G116
144 SF
PRINT/COPY
C410A
64 SF
TOILET 4
G116A
64 SF
TOILET 2
G117A
287 SF
CORRIDOR 4
C410
139 SF
CONTROL ROOM
G114
64 SF
TOILET 3
G115A
64 SF
TOILET 1
G113A
200 SF
SLEEP ROOM 1
G113
198 SF
SLEEP ROOM 2
G117
67 SF
TOILET 2
G118
148 SF
DIALYSIS
EQUIPMENT
G119
67 SF
TOILET 1
G112
90 SF
STERILE
EQUIPMENT
G111
113 SF
NEPHRO - LOGIST
G110
355 SF
CORRIDOR 2
C409 1
AE500B
B
A
6.3 6.4
B.8
C.8
D
F.8
AE503
8.1 9 10
AE400B
8 8.5
A L
IG
N
A L
IG
N
A L
IG
N
A L
IG
N
7' - 8" 5' - 8" 17' - 2" 12' - 2" 1' - 0" 7' - 5" 7' - 1" 13' - 4"
16' - 6" 13' - 4"
7' - 2"
3' - 0" 17' - 6" 13' - 2" 16' - 6" 13' - 4"
9' - 0" 10' - 10"
7' - 10"
A L
IG
N
9' - 4"
1' - 4"
A L
IG
N
7' - 0" 7' - 0"
1. CONTRACTOR SHALL FIELD VERIFY EXISTING DIMENSIONS AND
CONDITIONS BEFORE STARTING WORK.
2. WHEN LAYING OUT WALLS, CONTRACTOR SHALL TAKE FIELD
MEASUREMENTS TO ENSURE ALL REQUIRED CLEAR DIMENSIONS
ARE MAINTAINED AS INDICATED.
3. PENETRATIONS ARE NOT PERMITTED THROUGH STRUCTURAL
MEMBERS.
4. ALL EXPOSED WALL OUTSIDE CORNERS SHALL RECEIVE
CORNER GUARDS, PER PLAN.
5. WHERE FULL HEIGHT WALLS ARE SHOWN, FRAME WALL TO FORM
A TIGHT FIT AROUND EXISTING DUCT OR PIPING; SEAL ALL GAPS
AND CAULK ALL AROUND TO MAINTAIN INTEGRITY OF RATED
WALL WHERE APPLICABLE.
6. WHERE NEW DUCTS OR PIPING PENETRATE FULL HEIGHT
WALLS; SEAL ALL GAPS AND FIRE CAULK ALL AROUND TO
MAINTAIN INTEGRITY OF RATED WALL WHERE APPLICABLE.
7. IN ALL AREAS WITH DEPRESSED SLAB, FILL WITH CONCRETE
TOPPING PRIOR TO INSTALLING FLOOR FINISH.
8. ALL WALLS SHALL BE 4" METAL STUD WALLS, EXCEPT AT
EXTERIOR WALLS AND RECESSED FEC LOCATIONS PROVIDE 6"
METAL STUDS.
GENERAL NOTES
LEGEND
2-HOUR FIRE RATED PARTITION)
1-HOUR FIRE RATED PARTITION
SMOKE PARTITION
V V ITEM - VA SUPPLIED & INSTALLED
VC ITEM - VA SUPPLIED & CONTRACTOR
INSTALLED
SOUND RATED PARTITION
FULL HEIGHT PARTITION
CEILING HEIGHT PARTITION
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C T
PROJECT
NORTH
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of
VA MARTINEZ CAMPUS , CA
19 & 20K. F. DAVIS ENGINEERING INC.
530 LA GONDA WAY, SUITE E
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
KEY PLAN
B
BUILDING 19
BUILDING 20
02/25/2020
2/24/2020 3:25:45 PMH:\REVIT USER FILES\2018\CHRONIC DIALYSIS FINAL STAMPED SUBMITTAL - REV 2 - V2018_RonKorte1120.rvt
CHRONIC DIALYSIS AND
SLEEP PROGRAM
D.DIMAT
AE102.2B
ARCHITECTURAL ENLARGED PLAN
EAST - ADDITION B
J.ROBERTS
612-502
D.DIMAT
1/4" = 1'-0"AE102.2B
1 ADDITION B ENLARGED PLAN EAST
M A
T C
H L
IN
E
S E
E A
S B
M A
T C
H L
IN
E
S E
E A
S B
PROJECT
NORTH
SHEET NOTES
FRIDGE FREEZER
C O
L D
HOT
C O
L D
HOT
F.E.C.
F.E.C.
F.E.C.
F .E
.C
1. CONTRACTOR SHALL FIELD VERIFY EXISTING DIMENSIONS AND
CONDITIONS BEFORE STARTING WORK.
2. WHEN LAYING OUT WALLS, CONTRACTOR SHALL TAKE FIELD
MEASUREMENTS TO ENSURE ALL REQUIRED CLEAR DIMENSIONS ARE
MAINTAINED AS INDICATED. PENETRATIONS ARE NOT PERMITTED
THROUGH STRUCTURAL MEMBERS.
3. CONTRACTOR SHALL PATCH, LEVEL, AND PREPARE EXISTING FLOOR
SLAB TO RECEIVE NEW FLOORING. THIS INCLUDES REMOVAL OF LEFT-
OVER SUBSTRATES FROM DEMOLITION WORK AND FILLING ANY VOIDS
OR NON-LEVEL SURFACES WHERE THEY OCCUR, WITH CONCRETE
LEVELING COMPOUND AS REQUIRED.
4. ALL EXPOSED WALL OUTSIDE CORNERS SHALL RECEIVE CORNER
GUARDS, PER PLAN.
5. ALL EXPOSED END WALLS SHALL RECEIVE END WALL GUARDS, PER
PLAN.
6. WHERE FULL HEIGHT WALLS ARE SHOWN, FRAME WALL TO FORM A
TIGHT FIT AROUND EXISTING DUCT OR PIPING; SEAL ALL GAPS AND
CAULK ALL AROUND TO MAINTAIN INTEGRITY OF RATED WALL WHERE
APPLICABLE.
7. WHERE NEW DUCTS OR PIPING PENETRATE FULL HEIGHT WALLS; SEAL
ALL GAPS AND FIRE CAULK ALL AROUND TO MAINTAIN INTEGRITY OF
RATED WALL WHERE APPLICABLE.
8. WHERE (N) POWER AND TELEPHONE, DATA LINES AND OUTLETS ARE
INSTALLED ON (E) FINISHED WALLS, REPLACE GYP BOARD AND
INSULATION & PATCH TO MATCH ADJACENT FINISH.
9. ALL WALLS SHALL BE 3-5/8" METAL STUD WALLS, EXCEPT AT PLUMBING
WALLS AND RECESSED FEC LOCATIONS PROVIDE 6" METAL STUDS. MIN.
10. ALL GROUT JOINTS SHALL FORM A WATERPROOF SEAL BETWEEN
INDIVIDUAL TILES.
11. PROVIDE .50-13F (0.07 IN) WIRE DIAMETER ALLOY #304 STAINLESS STEEL
WOVEN MESH, INSIDE PHARMACY AND INTERIOR WALLS INCLUDING
WALLS ABOVE DOORS AND WINDOWS AND BELOW WINDOWS. ALL
VENTS, DUCTS, AND SIMILAR OPENINGS IN EXCESS OF 96 SQUARE
INCHES (620 CM²) THAT ENTER OR PASS THROUGH A PERIMETER
PARTITION TO THE PHARMACY SHALL BE PROTECTED WITH EITHER
BARS OR GRILLS. WHERE ONE DIMENSION OF THE DUCT MEASURES
LESS THAN SIX INCHES (150 MM) OR DUCTS IS LESS THAN 96 SQUARE
INCHES (620 CM²) BARS ARE NOT REQUIRED; HOWEVER, ALL DUCTS
SHALL BE TREATED TO PROVIDE SUFFICIENT SOUND ATTENUATION.
WHERE BARS ARE USED, THEY SHALL BE 1/2 INCH (12.7 mm) DIAMETER STEEL WELDED VERTICALLY AND HORIZONTALLY SIX INCHES (150mm)
ON CENTER; WHERE GRILLS ARE USED, THEY SHALL BE OF 9-GAUGE
EXPANDED STEEL. OPENINGS IN CONSTRUCTION ABOVE CEILINGS OR
BELOW RAISED ACCESS FLOORS SHALL BE PROTECTED AS ABOVE.
12. PROVIDE SECURITY MESH WINDOWS .50-13F (0.07IN) WIRE DIAMETER
ALLOY #304 STAINLESS STEEL WOVEN MESH ON WINDOWS AT
PHARMACY.
GENERAL NOTES
SYMBOL
1-HOUR FIRE RATED PARTITION
SMOKE PARTITION
FULL HEIGHT PARTITION
CEILING HEIGHT PARTITION
CMU WALL
CORNER GUARD/END WALL GUARD
HANDRAIL/WALL GUARD COMBINATION
CHAIR RAIL
FULLY RECESSED FIRE EXTINGUISHER
CABINET
MODULAR WALL PARTITIONS
LEGEND
CG EG
FEC
T.O.SLAB
0"
B.O. CEILING LINE
9' - 0"
T.O.SLAB
0"
APEX
25' - 6"
TOP OF PLATE B
11' - 0"
B.O. CEILING LINE
9' - 0"
2 4
AE103C
AE103C
CONSULT
H200
CONFERENCE
H201
VAULT
H301
PREP AND
PACKAGING
H300
BREAKROOM
H302
DINING
H100
FOOD PREP
H103
RECEIVING STOR
H104
RETAIL SPACE
H101
FOR CONTINUATION
SEE SHEET AE103.2C
FOR CONTINUATION
SEE SHEET AE103.1C
32 33 37.1 38 40
42 44 48 50 52 53 54 57 60 63 68 7040.8 48.2 74
B27
B25
B23
E L
E C
T R
IC
A
L R
O O
M
H A
B30
B31
B29
B28
B26
1 EXISTING BUILDING STRUCTURE
2 EXISTING CONCRETE FOUNDATION
3 EXISTING EXTERIOR WALL
4 5/8" GYP BD TYPICAL AT INTERIOR WALLS
5 METAL STUD FRAMING
6 CMU WALL
SHEET NOTES
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C T
PROJECT
NORTH
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of
VA MARTINEZ CAMPUS , CA
19 & 20K. F. DAVIS ENGINEERING INC.
530 LA GONDA WAY, SUITE E
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
KEY PLAN
C
BUILDING 19
BUILDING 20
02/25/2020
2/24/2020 3:26:13 PMH:\REVIT USER FILES\2018\CHRONIC DIALYSIS FINAL STAMPED SUBMITTAL - REV 2 - V2018_RonKorte1120.rvt
CHRONIC DIALYSIS AND
SLEEP PROGRAM
D.DIMAT
AE103C
ARCHITECTURAL FLOOR PLAN -
RENOVATION C
J.ROBERTS
612-502
D.DIMAT
PROJECT
NORTH
1/8" = 1'-0"AE103C
2 LONGITUDINAL SECTION - ADDITION C
1/8" = 1'-0"AE103C
3 CROSS SECTION - ADDITION C
1/8" = 1'-0"AE103C
1 RENOVATION C FLOOR PLAN 1/8"
PROVIDE:
1. PROVIDE THIS RECEPTION DESK WITH ALL THE UTILITIES BEFORE DEMOLISHING THE RECEPTION NEAR THE ATM MACHINE.
2. PROVIDE CUSTOM MADE ROUND OR SQUARE ADA RECEPTION DESK APPROX 12'-0" DIA OR 12'-10" SQUARE.
3. PROVIDE 2 DUPLEX ELECTRICAL OUTLET.
4. PROVIDE 1 COMM OUTLET WITH 4 PORTS.
5. PROVIDE A CHASE FOR UTILITIES, METAL OR DRYWALL PAINTED COMING FROM THE CEILING.
FRIDGE
1. CONTRACTOR SHALL FIELD VERIFY EXISTING DIMENSIONS AND
CONDITIONS BEFORE STARTING WORK.
2. WHEN LAYING OUT WALLS, CONTRACTOR SHALL TAKE FIELD
MEASUREMENTS TO ENSURE ALL REQUIRED CLEAR DIMENSIONS ARE
MAINTAINED AS INDICATED. PENETRATIONS ARE NOT PERMITTED
THROUGH STRUCTURAL MEMBERS.
3. CONTRACTOR SHALL PATCH, LEVEL, AND PREPARE EXISTING FLOOR
SLAB TO RECEIVE NEW FLOORING. THIS INCLUDES REMOVAL OF LEFT-
OVER SUBSTRATES FROM DEMOLITION WORK AND FILLING ANY VOIDS
OR NON-LEVEL SURFACES WHERE THEY OCCUR, WITH CONCRETE
LEVELING COMPOUND AS REQUIRED.
4. ALL EXPOSED WALL OUTSIDE CORNERS SHALL RECEIVE CORNER
GUARDS, PER PLAN.
5. ALL EXPOSED END WALLS SHALL RECEIVE END WALL GUARDS, PER
PLAN.
6. WHERE FULL HEIGHT WALLS ARE SHOWN, FRAME WALL TO FORM A
TIGHT FIT AROUND EXISTING DUCT OR PIPING; SEAL ALL GAPS AND
CAULK ALL AROUND TO MAINTAIN INTEGRITY OF RATED WALL WHERE
APPLICABLE.
7. WHERE NEW DUCTS OR PIPING PENETRATE FULL HEIGHT WALLS; SEAL
ALL GAPS AND FIRE CAULK ALL AROUND TO MAINTAIN INTEGRITY OF
RATED WALL WHERE APPLICABLE.
8. WHERE (N) POWER AND TELEPHONE, DATA LINES AND OUTLETS ARE
INSTALLED ON (E) FINISHED WALLS, REPLACE GYP BOARD AND
INSULATION & PATCH TO MATCH ADJACENT FINISH.
9. ALL WALLS SHALL BE 3-5/8" METAL STUD WALLS, EXCEPT AT PLUMBING
WALLS AND RECESSED FEC LOCATIONS PROVIDE 6" METAL STUDS. MIN.
10. ALL GROUT JOINTS SHALL FORM A WATERPROOF SEAL BETWEEN
INDIVIDUAL TILES.
11. PROVIDE .50-13F (0.07 IN) WIRE DIAMETER ALLOY #304 STAINLESS STEEL
WOVEN MESH, INSIDE PHARMACY AND INTERIOR WALLS INCLUDING
WALLS ABOVE DOORS AND WINDOWS AND BELOW WINDOWS. ALL
VENTS, DUCTS, AND SIMILAR OPENINGS IN EXCESS OF 96 SQUARE
INCHES (620 CM²) THAT ENTER OR PASS THROUGH A PERIMETER
PARTITION TO THE PHARMACY SHALL BE PROTECTED WITH EITHER
BARS OR GRILLS. WHERE ONE DIMENSION OF THE DUCT MEASURES
LESS THAN SIX INCHES (150 MM) OR DUCTS IS LESS THAN 96 SQUARE
INCHES (620 CM²) BARS ARE NOT REQUIRED; HOWEVER, ALL DUCTS
SHALL BE TREATED TO PROVIDE SUFFICIENT SOUND ATTENUATION.
WHERE BARS ARE USED, THEY SHALL BE 1/2 INCH (12.7 mm) DIAMETER STEEL WELDED VERTICALLY AND HORIZONTALLY SIX INCHES (150mm)
ON CENTER; WHERE GRILLS ARE USED, THEY SHALL BE OF 9-GAUGE
EXPANDED STEEL. OPENINGS IN CONSTRUCTION ABOVE CEILINGS OR
BELOW RAISED ACCESS FLOORS SHALL BE PROTECTED AS ABOVE.
12. PROVIDE SECURITY MESH WINDOWS .50-13F (0.07IN) WIRE DIAMETER
ALLOY #304 STAINLESS STEEL WOVEN MESH ON WINDOWS AT
PHARMACY.
GENERAL NOTES
SHEET NOTES
SINK WITH EYEWASH
STORAGE SHELVES (V V)
REFRIGERATOR SPACE VERIFY SIZE WITH REFRIGERATOR
MANUFACTURER
BUILT-IN BASE CABINET
BUILT-IN UPPER CABINET
REFRIGERATOR (V V)
PACKAGING MACHINE ( V V)
UNIT DOSE (V V)
MEDICATION CART (V V )
MODULAR WORK STATIONS (V V)
2 1/2" WALL FURRING
PROVIDE SECURITY MESH AT PHARMACY WINDOWS
AE103C
31' - 11" 20' - 1"
CONSULT
CONFERENCE
VAULT
PREP AND
PACKAGING
BREAKROOM
F O
R C
O N
T
IN
U A
T
IO
N
S E
E S
H E
E T
A E
.2
C F
O R
C O
N T
IN
U
A T
IO
N
S E
E S
H E
E T
A E
.2
C
32 33 37.1 38 40
42 44 48 50 52 5340.8 48.2
B27
ELECTRICAL
ROOM
2 2
B30
B31
B29
B28
B26
ALIGN
A L
IG
N
A L
IG
N
10' - 8" 2' - 3" 5' - 0" 12' - 10"
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C T
PROJECT
NORTH
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of
VA MARTINEZ CAMPUS , CA
19 & 20K. F. DAVIS ENGINEERING INC.
530 LA GONDA WAY, SUITE E
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
KEY PLAN
C
BUILDING 19
BUILDING 20
02/25/2020
2/24/2020 3:25:56 PMH:\REVIT USER FILES\2018\CHRONIC DIALYSIS FINAL STAMPED SUBMITTAL - REV 2 - V2018_RonKorte1120.rvt
CHRONIC DIALYSIS AND
SLEEP PROGRAM
D.DIMAT
AE103.1C
ARCHITECTURAL ENLARGED PLAN
WEST - RENOVATION C AND FOOD
SERVICE EQUIPMENT SCHEDULE
J.ROBERTS
612-502
D.DIMAT
PROJECT
NORTH
1/4" = 1'-0"AE103.1C
1 RENOVATION C ENLARGED PLAN - WEST
FRIDGE FREEZER
C O
L D
HOT
C O
L D
HOT
F.E.C.
F.E.C.
F .E
.C
1. CONTRACTOR SHALL FIELD VERIFY EXISTING DIMENSIONS AND
CONDITIONS BEFORE STARTING WORK.
2. WHEN LAYING OUT WALLS, CONTRACTOR SHALL TAKE FIELD
MEASUREMENTS TO ENSURE ALL REQUIRED CLEAR DIMENSIONS ARE
MAINTAINED AS INDICATED. PENETRATIONS ARE NOT PERMITTED
THROUGH STRUCTURAL MEMBERS.
3. CONTRACTOR SHALL PATCH, LEVEL, AND PREPARE EXISTING FLOOR
SLAB TO RECEIVE NEW FLOORING. THIS INCLUDES REMOVAL OF LEFT-
OVER SUBSTRATES FROM DEMOLITION WORK AND FILLING ANY VOIDS
OR NON-LEVEL SURFACES WHERE THEY OCCUR, WITH CONCRETE
LEVELING COMPOUND AS REQUIRED.
4. ALL EXPOSED WALL OUTSIDE CORNERS SHALL RECEIVE CORNER
GUARDS, PER PLAN.
5. ALL EXPOSED END WALLS SHALL RECEIVE END WALL GUARDS, PER
PLAN.
6. WHERE FULL HEIGHT WALLS ARE SHOWN, FRAME WALL TO FORM A
TIGHT FIT AROUND EXISTING DUCT OR PIPING; SEAL ALL GAPS AND
CAULK ALL AROUND TO MAINTAIN INTEGRITY OF RATED WALL WHERE
APPLICABLE.
7. WHERE NEW DUCTS OR PIPING PENETRATE FULL HEIGHT WALLS; SEAL
ALL GAPS AND FIRE CAULK ALL AROUND TO MAINTAIN INTEGRITY OF
RATED WALL WHERE APPLICABLE.
8. WHERE (N) POWER AND TELEPHONE, DATA LINES AND OUTLETS ARE
INSTALLED ON (E) FINISHED WALLS, REPLACE GYP BOARD AND
INSULATION & PATCH TO MATCH ADJACENT FINISH.
9. ALL WALLS SHALL BE 3-5/8" METAL STUD WALLS, EXCEPT AT PLUMBING
WALLS AND RECESSED FEC LOCATIONS PROVIDE 6" METAL STUDS. MIN.
10. ALL GROUT JOINTS SHALL FORM A WATERPROOF SEAL BETWEEN
INDIVIDUAL TILES.
11. PROVIDE .50-13F (0.07 IN) WIRE DIAMETER ALLOY #304 STAINLESS STEEL
WOVEN MESH, INSIDE PHARMACY AND INTERIOR WALLS INCLUDING
WALLS ABOVE DOORS AND WINDOWS AND BELOW WINDOWS. ALL
VENTS, DUCTS, AND SIMILAR OPENINGS IN EXCESS OF 96 SQUARE
INCHES (620 CM²) THAT ENTER OR PASS THROUGH A PERIMETER
PARTITION TO THE PHARMACY SHALL BE PROTECTED WITH EITHER
BARS OR GRILLS. WHERE ONE DIMENSION OF THE DUCT MEASURES
LESS THAN SIX INCHES (150 MM) OR DUCTS IS LESS THAN 96 SQUARE
INCHES (620 CM²) BARS ARE NOT REQUIRED; HOWEVER, ALL DUCTS
SHALL BE TREATED TO PROVIDE SUFFICIENT SOUND ATTENUATION.
WHERE BARS ARE USED, THEY SHALL BE 1/2 INCH (12.7 mm) DIAMETER STEEL WELDED VERTICALLY AND HORIZONTALLY SIX INCHES (150mm)
ON CENTER; WHERE GRILLS ARE USED, THEY SHALL BE OF 9-GAUGE
EXPANDED STEEL. OPENINGS IN CONSTRUCTION ABOVE CEILINGS OR
BELOW RAISED ACCESS FLOORS SHALL BE PROTECTED AS ABOVE.
12. PROVIDE SECURITY MESH WINDOWS .50-13F (0.07IN) WIRE DIAMETER
ALLOY #304 STAINLESS STEEL WOVEN MESH ON WINDOWS AT
PHARMACY.
GENERAL NOTES
FOOD SERVICE EQUIPMENT SCHEDULE
ITEMNO. STEAM
ELECTRICAL
MODEL L/W/H
SIZE
WALL
SUPPLIER/
INSTALLER KW/AMPSVOLTS
POWER
STEAM GAS WASTE
HOT COLD
WATER
ELEC
GREASE
LADEN
GAS
LADEN AIR
HEAT OR
MOISTURE
B9
3/8"22/22/37 VC 26AB10 COFFEE BREWER (3-Wires + Ground)
DISPENSER
BEVERAGE/ICE
B8
COKE
PROVIDED BY
30/30/38 VV 2.5A120/1 1/2"
FLOOR
DRAIN
VV9/18/34
GOLD PEAK
TEA DISPENSER
120/1
PROVIDED
BY COKE VENDOR
1/4"2.5A
B6
DISPENSE-RITE
WR-CT-4
7/20/24 VV
VV7/20/19
DISPENSE-RITE
WR-CT-3B7 HOT CUP DISPENSER
COLD CUP DISPENSER
(2)
BUNN
ICB TWIN TALL
120/208
13/20/31 VC 2.8AB13 COFFEE CREAMER
BUILT
IN
INTERNATIONAL
DELIGHT
120/1
K18
REFRIGERATOR
2 SECTION
TS-49
TRUE
AFF
48"
VC 115/1 9.1A541_
/291_
/783_
K19 FREEZER
2 SECTION
TS-49F
TRUE
AFF
48"
VC 115/1 13.2A541_
/291_
/783_
K15 48"
AFF
208/1 20.38A
STRUCT CONCEPTS
B8832
REFRIGERATED
SELF-SERVER CASE
NEMA 6-30P
FLOOR
DRAIN883_
/321_
/821_
VC
B1 BEVERAGE COUNTER FABRICATED 120/46/34 VC
12"
AFF
120/1 6.2A * SEE NOTE BELOW
INCLUDE POWER FOR
B8, B8A, B9, B10 & B13
1/2"B8A ICE MACHINE HOSHIZAKI
KMD-460MAH 30/24/22 VC 120/1 15A FLOOR
DRAIN
ES1 ENTREES AND SIDES 96/46/34 AFF
12" 208/1 28A 3/8" 3/4"
FABRICATED W/
3 HOT 2 COLD WELLS VC * SEE NOTE BELOW
3/8"11/23/30 VC 15AB11 CAPPUCCINO MACHINE BUNN
FMD-3
120/1
K11 HOOD 98/42 CC
ES13
1 SECTION
WARMER
ALTO SHAM
1200-UP/SR/STD 24/32/74 VC 48"
AFF 120/1 19.3A
C1 CONDIMENT STAND FABRICATED 60/30/45 VC
****PROVIDE LEFT HAND SWING DOORS****
1 PHASE
EQUIPMENT SPECIFICATIONS
ALTERNATE
ENERGY SOURCEPREFERRED ENERGY SOURCE PLUMBING VENTILATION ADDITIONAL
NOTES
FOOD SERVICE EQUIPMENT SCHEDULE
ITEMNO. STEAM
ELECTRICAL
MODEL L/W/H
SIZE
WALL
SUPPLIER/
INSTALLER KW/AMPSVOLTS
POWER
STEAM GAS WASTE
HOT COLD
WATER
ELEC
GREASE
LADEN
GAS
LADEN AIR
HEAT OR
MOISTURE
12"
AFF
OG1 96/46/34 3/8"
FABRICATED W/3
HOT 2/COLD WELLS
OFF THE GRILL VC
OG3
1-DRAWER WARMER
(BUILT-IN)
HATCO
HDW-1BN
20/28/10 VC
OG11 FRYER - ELECTRIC
FRYMASTER OCF30ATOE
FPEL214-LCA
31/31/46 18"
AFF
VC 208/3 39A X X
6.9A120/1 12"
AFF16/36/40FRYMASTER
DUMP TABLE W/
HEAT LAMPOG5 VC
OG8 HOLDING BIN DUKE
FWM3-42 21X16X22
12"
AFF
120/1 13.3AVC
33A208/1
FLOOR
DRAIN
***BUILT INTO OG1 LOAD CTR***
* SEE NOTE BELOW
K50 TOASTER
TRH-60
HATCO
18/23/16
AFF
36"
VC 208/1 18.3A
FREEZER WORK TABLEOG9
TWT-48F
TRUE 115/1
AFF
12"
VC 6.6A483_
/301_
/333_
K44
BAG-IN-BOX
SHELVES 42/18/87 VVPROVIDED BY COKE
K45 LINE CONDUIT, 6"
CO2/SYRUP
CC
BUILT
IN
K35 POT & PAN RACK 48/24 VCMETRO PR48X3
22A
8KW208/312"
AFF36/30/3636x30 E
KEATINGOG13 GRIDDLE X XVC
PROVIDE DEDICATED CIRCUITSTUB
UP
R1 CASH REGISTER (2)
NCR
RealPOS 70xrt 12/141_
/141_
VV
K42 MOBILE SHELF 48/18/78EMU184878P580
CAMBRO
K43 DUNNAGE SHELF (3) 48/21/12DRS 480
CAMBRO
VC
VC
TS1 TRAY STAND FABRICATED SEE PLAN/24 VC ***SEE NOTE BELOW***
K23 HAND SINK 22/20/34 CC X X X
208/3 39A
12"
AFF
TRASH COMPACTORT1 25/24/49 VC 3A120/1
COMPACTION
TECHNOLOGIES
R42
CPMU183675V4
CAMBROSLIDING RACK STORAGE
SYSTEM (8)
36/18/75 VV
EQUIPMENT SPECIFICATIONS
ALTERNATE
ENERGY SOURCEPREFERRED ENERGY SOURCE PLUMBING VENTILATION ADDITIONAL
NOTES
VV = VCS PURCHASE AND INSTALL
VC = VCS PURCHASE AND VAMC CONSTRUCTION CONTRACTOR
INSTALL
CC = VAMC CONSTRUCTION CONTRACTOR PURCHASE AND INSTALL
* NOTE: FABRICATE COUNTER PIECES NO LONGER THAN 8'-0"
FOR EASE OF DELIVERY. IF SHOWN LARGER ABOVE, BREAK
INTO MULTIPLE PARTS.
DINING EQUIPMENT SCHEDULE
TOTAL NUMBER OF SEATS
FOUR SEAT, 36"x36" TABLE W/4 CHAIRS
48"X30" TABLE W/3 CHAIRS/HANDICAP
D8
D6A
NO. ITEM
36"x36"VC 5
SIZE
48"x30"VC
SUPPLIER/
INSTALLER
QUANTITY
# OF SEATS
ALL FREESTANDING TABLES ARE 30" AFF, MEETING HANDICAP REGULATIONS.
THOSE MARKED HANDICAP ARE 32" AFF TO SUPPORT TODAY'S LARGER
WHEELCHAIRS.
24"X27" TABLE W/2 CHAIRSD6 24"x27"VC 9 18
FOUR SEAT, 36"x36" TABLE W/3 CHAIRS/HANDICAPD8A VC 1 436"x36"
LEGEND
V V ITEM - VA SUPPLIED & INSTALLED
VC ITEM - VA SUPPLIED & CONTRACTOR INSTALLED
AE103C
AE103C
DINING
FOOD PREP
PROJECT
NORTH
F O
R C
O N
T
IN
U A
T
IO
N
S E
E S
H E
E T
A E
.1
C
RETAIL SPACE
RECEIVING STOR
D6 D6A
D8A D8
D8 D8
D8 D8
D6
D6
D6
D6
D6
D6
D6
T1
J
J
T1C1TS1
K15
R42 R42 R42 R42
OG1
ES1
K18 K19 B10 B8AB9
K44
K45
ES13
K23
0G9
K50
0G8
0G5
0G11
0G11
0G13 K11 0G3
K43 K43
B13
B7 B1 B6 B6
52 53 54 57 60 63 68 70 74
B27
ELECTRICAL
ROOM
B30
B31
B29
B28
6' - 0" 14' - 3" 22' - 0" 27' - 2"
15' - 5" 31' - 6" 22' - 6"
10"
1' - 1"
2' - 4"
4' - 7"
7' - 5"
14' - 9"
A
WINDOW SCHEDULE
ADDITION C
MARK TYPE ROUGHT
OPENING
UNIT SIZE
(WxH)
FRAME
DEPTH
FRAME
WIDTH
FRAME
MATERIAL
FRAME
FINISH
HEAD HEIGHT
(AFF)
GLAZING
TYPE
REMARKS
A
EXT. FIXED
STOREFRONT
14'-9" x 3'-7" 14'-8" x 3'-6" 2" 4 1/2" ALUMINUM
ANODIZED
ALUMINUM
7'-2" DUAL GLAZED TEMP
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C T
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of
VA MARTINEZ CAMPUS , CA
19 & 20K. F. DAVIS ENGINEERING INC.
530 LA GONDA WAY, SUITE E
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
02/25/2020
2/24/2020 3:26:00 PMH:\REVIT USER FILES\2018\CHRONIC DIALYSIS FINAL STAMPED SUBMITTAL - REV 2 - V2018_RonKorte1120.rvt
CHRONIC DIALYSIS AND
SLEEP PROGRAM
D.DIMAT
AE103.2C
ARCHITECTURAL ENLARGED PLAN
EAST - RENOVATION C AND FOOD
SERVICE EQUIPMENT SCHEDULE
J.ROBERTS
612-502
D.DIMAT
1/4" = 1'-0"AE103.2C
1 RENOVATION C ENLARGED PLAN - EAST
.C
F .E
.C
C
GCG
CG
CG
CG
CG
F.E.C.
F .E
.C
F.E.C.
FRIDGE FREEZER
C O
L D
HOT
C O
L D
HOT
F.E.C.
F.E.C.
F.E.C.
F .E
.C
TOILET 1
19A101
TOILET 2
19A102
SUPPLY
19A100B
PREP
19A100A
SEATING
19A100
CORRIDOR
C19A
P-2
P-1 TYP
UNO
P-1 TYP
UNO
P-1 TYP
UNO
P-3
P-3
P-3
TYP OF (4)
TYP OF (3)
SLEEP ROOM 3
G115
SLEEP ROOM 4
G116
PRINT/COPY
C410A
TOILET 4
G116A
TOILET 2
G117A
CORRIDOR 4
C410
CONTROL ROOM
G114
TOILET 3
G115A
TOILET 1
G113A
SLEEP ROOM 1
G113
SLEEP ROOM 2
G117TOILET 2
G118
DIALYSIS
EQUIPMENT
G119
TOILET 1
G112
NEPHRO - LOGIST
G110
CORRIDOR 2
C409
CONFERENCE
OPEN OFFICE
G100
E L
E C
T R
IC
A
L
R O
O M
G
CONSULT
G107
CHIEF
G106
TELECOM
G105
SUPV
G104
SUPV
G103
SUPV
G102
UTILITY CLOSET
G111A
CORRIDOR 3
C408
CORRIDOR 1
C411
5' - 0"
4' - 0"
4' - 3"
P-4P-4
P-1 TYP
UNO
P-2
P-3
P-4P-4
P-3
P-1 TYP
UNO
P-4
P-3
P-4
P-1 TYP
UNO
P-2
TYP OF (6)
TYP OF (16)
TYP OF (4)
CONSULT
H200
CONFERENCE
H201
VAULT
H301
PREP AND
PACKAGING
H300
BREAKROOM
H302
DINING
H100
FOOD PREP
H103
RECEIVING STOR
H104
E L
E C
T R
IC
A
L
R O
O M
H A
P-1 TYP
UNO
P-1
TYP
UNO
P-1 TYP
UNO
P-1 TYP
UNO
P-2 P-3
P-3
P-3
P-3
P-4
P-3
P-2 P-3
TYP OF (13)
TYP OF (9)
GENERAL NOTES
1. THE FURNITURE PLAN SHOWS A GENERAL LAYOUT OF A VA
PROVIDED AND VA INSTALLED FURNITURE IN ORDER TO ASSIST
CONTRACTOR TO COORDINATE THE LOCATION OF POWER AND
DATA OULETS.
2. TYPICAL PAINT COLOR THROUGHOUT FOR WALLS AND CEILINGS IS
P=1.
3. SEE SPECIFICATION 09 06 00 FOR PAINT COLORS.
4. ACCENT WALL COLORS SHALL BE PAINTED THE FULL LENGTH OF
THE WALL INDICATED FROM CORNER TO CORNER.
SHEET NOTES
1 DESK AND CHAIRS - TYP
2 MODULAR WORKSTATION - TYP
3 CONFERENCE TABLE AND CHAIRS - TYP
4 BED, NIGHT TABLE, AND CHAIR - TYP
5 BAR STOOL - TYP
6 TABLE AND CHAIRS - TYP
7 ROUND TABLE AND - TYP
8 MODULAR SHELVES - TYP
P-1
PAINT LEGEND
TYPICAL IN FIELD, KELLY MOORE, PICKET
FENCE, KM46
ACCENT, KELLY MOORE, TIN MAN, KM942
ACCENT, BLUE AGAVE, KM4865-1
ACCENT, KELLY MOORE, ANGELIC EYES,
KM4976
P-2
P-3
P-4
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C T
PROJECT
NORTH
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of
VA MARTINEZ CAMPUS , CA
19 & 20K. F. DAVIS ENGINEERING INC.
530 LA GONDA WAY, SUITE E
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
KEY PLAN
A
C
B
BUILDING 19
BUILDING 20
02/25/2020
2/27/2020 10:21:09 AMC:\Users\ashrestha\Documents\CHRONIC DIALYSIS FINAL STAMPED SUBMITTAL - REV 2 - V2018_anil.shrestha9MD6R.rvt
CHRONIC DIALYSIS AND
SLEEP PROGRAM
D.DIMAT
AE104
ARCHITECTURAL FURNITURE PLAN
J.ROBERTS
612-502
D.DIMAT
1/4" = 1'-0"AE104
1 ADDITION A FURNITURE PLAN PROJECT
NORTH
1/8" = 1'-0"AE104
2 ADDITION B FURNITURE PLAN PROJECT
NORTH
1/8" = 1'-0"AE104
3 RENOVATION C FURNITURE PLAN
PROJECT
NORTH
.C
JK
500 SF
SEATING
19A100
218 SF
PREP
19A100A
85 SF
SUPPLY
19A100B
56 SF
TOILET 2
19A102
56 SF
TOILET 1
19A101
62 SF
CORRIDOR
C19A
AE500A
12.9
AE500A
HL
AE503
AE503
LAY-IN RESIN PANEL
LENSES x 4 "LUMICOR"
WOODLAND DIGITAL 1/2"
THICK, OR VA APPROVED
EQUAL
GENERAL NOTES
1 BEFORE LAYING OUT DUCTWORK, PIPING, CONDUITS
AND/OR UTILITIES ABOVE CEILING, COORDINATE CEILING
SUSPENSION SYSTEM SUPPORT LOCATIONS TO AVOID
CONFLICTS.
2 WHERE INTERFERENCE WITH CEILING SUPPORTS
CANNOT BE AVOIDED THE CONTRACTOR SHALL
PROVIDE AN ALTERNATE SUSPENSION SYSTEM IN
COMPLIANCE WITH APPLICABLE CODES AND STANDARDS
AT NO ADDITIONAL COST TO THE GOVERNMENT.
3 ACCESS PANEL (NOT ALL SHOWN) SHALL BE PROVIDED
FOR ALL EQUIPMENT ABOVE THE CEILING OR IN THE
WALLS INCLUDING BUT NOT LIMITED TO; ELECTRICAL
JUNCTION BOXES, MOTORS, VAV BOXES, VALVES,
DAMPERS AND SIMILAR EQUIPMENT. ACCESS PANELS
SHALL BE LOCATED WITHIN ONE FOOT OF EQUIPMENT.
NEW ACCESS PANELS SHALL BE 24” X 24” MINIMUM SIZE
(FIRE RATED WHERE APPLICABLE) AND SHALL BE
FABRICATED PER SPEC. SECTION 08 31 13.
4 THE CONTRACTOR SHALL COORDINATE WITH EACH
DISCIPLINE AND LOCATE ADDITIONAL ACCESS PANELS
FOR REVIEW AND APPROVAL BY THE VA PRIOR TO
INSTALLING THE CEILING.
5 TYPICAL CEILING HEIGHT: 8’- 0” A.F.F.
6 CORRIDOR AND AT CEILINGS: 9’- 0” A.F.F.
ACOUSTICAL TILE CEILING
LEGEND
ACOUSTICAL TILE CEILING WITH SPECIAL FINISH (SP)
GYPSUM BOARD CEILING/SOFFIT
RECESSED LIGHT FIXTURES 2x2
REGISTERS
RECESSED LIGHT FIXTURES 2x4
CEILING SURFACE-MOUNTED
SUSPENDED FROM CENTERED
LINEAR METAL CEILING
SHEET NOTES
EXPANSION JOINT COVER
EXPANSION JOINT
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C T
PROJECT
NORTH
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of
VA MARTINEZ CAMPUS , CA
19 & 20K. F. DAVIS ENGINEERING INC.
530 LA GONDA WAY, SUITE E
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
KEY PLAN
A
BUILDING 19
BUILDING 20
02/25/2020
2/24/2020 3:26:23 PMH:\REVIT USER FILES\2018\CHRONIC DIALYSIS FINAL STAMPED SUBMITTAL - REV 2 - V2018_RonKorte1120.rvt
CHRONIC DIALYSIS AND
SLEEP PROGRAM
D.DIMAT
AE201A
ARCHITECTURAL REFLECTED
CEILING PLAN - ADDITION A
J.ROBERTS
612-502
D.DIMAT
1/4" = 1'-0"AE201A
1 ADDITION A REFLECTED CEILING PLAN PROJECT
NORTH
.E
.C
F.E.C.
1 2 3 4 6 7
C
E
F
G
CHIEF
G106
CONSULT
G107
ELECTRICAL
ROOM
G108
CORRIDOR 1
C411
TELECOM
G105
SUPV
G104
SUPV
G103
SUPV
G102
OPEN OFFICE
G100
CONFERENCE
G109
NEPHRO -
LOGIST
G110
CORRIDOR 3
C408
DIALYSIS
EQUIPMENT
G119
TOILET 2
G118
TOILET 1
G112
S T
E R
IL
E
E Q
U
IP
M E
N T
G
UTILITY
CLOSET
G111A
SLEEP ROOM
G113
SLEEP ROOM
G117
PRINT/COPY
C410A
CORRIDOR 4
C410
CONTROL
ROOM 1
G114
TOILET 1
G113A
TOILET 3
G115A
SLEEP ROOM
G115
SLEEP ROOM
G116
TOILET 4
G116A
TOILET 2
G117A
CONFERENCE
G109
CORRIDOR 2
C409
2.9
B
A
3.5 6.3 6.4
B.8
C.8
D
F.8
4.7 8.1 9 108 8.5
PROVIDE WALL TO CEILING
SEISMIC JOINT COVER
GENERAL NOTES
1. BEFORE LAYING OUT DUCTWORK, PIPING, CONDUITS
AND/OR UTILITIES ABOVE CEILING, COORDINATE CEILING
SUSPENSION SYSTEM SUPPORT LOCATIONS TO AVOID
CONFLICTS.
2. WHERE INTERFERENCE WITH CEILING SUPPORTS
CANNOT BE AVOIDED THE CONTRACTOR SHALL PROVIDE
AN ALTERNATE SUSPENSION SYSTEM IN COMPLIANCE
WITH APPLICABLE CODES AND STANDARDS AT NO
ADDITIONAL COST TO THE GOVERNMENT.
3. ACCESS PANEL (NOT ALL SHOWN) SHALL BE PROVIDED
FOR ALL EQUIPMENT ABOVE THE CEILING OR IN THE
WALLS INCLUDING BUT NOT LIMITED TO; ELECTRICAL
JUNCTION BOXES, MOTORS, VAV BOXES, VALVES,
DAMPERS AND SIMILAR EQUIPMENT. ACCESS PANELS
SHALL BE LOCATED WITHIN ONE FOOT OF EQUIPMENT.
NEW ACCESS PANELS SHALL BE 24” X 24” MINIMUM SIZE
(FIRE RATED WHERE APPLICABLE) AND SHALL BE
FABRICATED PER SPEC. SECTION 08 31 13.
4. THE CONTRACTOR SHALL COORDINATE WITH EACH
DISCIPLINE AND LOCATE ADDITIONAL ACCESS PANELS
FOR REVIEW AND APPROVAL BY THE VA PRIOR TO
INSTALLING THE CEILING.
5. TYPICAL CEILING HEIGHT: 9’- 0” A.F.F.
6. CORRIDOR CEILINGS: 8’- 0” A.F.F.
ACOUSTICAL TILE CEILING
LEGEND
ACOUSTICAL TILE CEILING WITH SPECIAL FINISH (SP)
GYPSUM BOARD CEILING/SOFFIT
RECESSED LIGHT FIXTURES 2x2
REGISTERS
RECESSED LIGHT FIXTURES 2x4
CEILING SURFACE-MOUNTED
SUSPENDED FROM CENTERED
LINEAR METAL CEILING
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C T
PROJECT
NORTH
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of
VA MARTINEZ CAMPUS , CA
19 & 20K. F. DAVIS ENGINEERING INC.
530 LA GONDA WAY, SUITE E
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
KEY PLAN
B
BUILDING 19
BUILDING 20
02/25/2020
2/24/2020 3:26:25 PMH:\REVIT USER FILES\2018\CHRONIC DIALYSIS FINAL STAMPED SUBMITTAL - REV 2 - V2018_RonKorte1120.rvt
CHRONIC DIALYSIS AND
SLEEP PROGRAM
D.DIMAT
AE201B
ARCHITECTURAL REFLECTED
CEILING PLAN - ADDITION B
J.ROBERTS
612-502
D.DIMAT
1/8" = 1'-0"AE201B
1 ADDITION B REFLECTED CEILING PLAN
PROJECT
NORTH
F.E.C.
F .E
.C
CONFERENCE
H201
CONSULT
H200
BREAKROOM
H302
VAULT
H301
AE103C
AE103C
FOOD PREP
H103
PREP AND
PACKAGING
H300
3029 32 33 37.1 38 40 41 42 44 48 50 52 53 54 57 60 63 68 70 7840.8 48.2 74
B27
B25
B21
B18
B23
ELECTRICAL
ROOM
H104A
RECEIVING
STOR
H104
B30
B31
B29
B28
B26
GENERAL NOTES
1. BEFORE LAYING OUT DUCTWORK, PIPING, CONDUITS
AND/OR UTILITIES ABOVE CEILING, COORDINATE
CEILING SUSPENSION SYSTEM SUPPORT LOCATIONS
TO AVOID CONFLICTS.
2. WHERE INTERFERENCE WITH CEILING SUPPORTS
CANNOT BE AVOIDED THE CONTRACTOR SHALL
PROVIDE AN ALTERNATE SUSPENSION SYSTEM IN
COMPLIANCE WITH APPLICABLE CODES AND
STANDARDS AT NO ADDITIONAL COST TO THE
GOVERNMENT.
3. ACCESS PANEL (NOT ALL SHOWN) SHALL BE
PROVIDED FOR ALL EQUIPMENT ABOVE THE CEILING
OR IN THE WALLS INCLUDING BUT NOT LIMITED TO;
ELECTRICAL JUNCTION BOXES, MOTORS, VAV BOXES,
VALVES, DAMPERS AND SIMILAR EQUIPMENT. ACCESS
PANELS SHALL BE LOCATED WITHIN ONE FOOT OF
EQUIPMENT. NEW ACCESS PANELS SHALL BE 24” X 24”
MINIMUM SIZE (FIRE RATED WHERE APPLICABLE) AND
SHALL BE FABRICATED PER SPEC. SECTION 08 31 13.
4. THE CONTRACTOR SHALL COORDINATE WITH EACH
DISCIPLINE AND LOCATE ADDITIONAL ACCESS PANELS
FOR REVIEW AND APPROVAL BY THE VA PRIOR TO
INSTALLING THE CEILING.
5. TYPICAL CEILING HEIGHT: 8’- 0” A.F.F.
6. LINEAR METAL CEILINGS: 8’- 9” A.F.F.
ACOUSTICAL TILE CEILING
LEGEND
ACOUSTICAL TILE CEILING WITH SPECIAL FINISH (SP)
GYPSUM BOARD CEILING/SOFFIT
RECESSED LIGHT FIXTURES 2x2
REGISTERS
RECESSED LIGHT FIXTURES 2x4
CEILING SURFACE-MOUNTED
SUSPENDED FROM CENTERED
LINEAR METAL CEILING
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C T
PROJECT
NORTH
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of
VA MARTINEZ CAMPUS , CA
19 & 20K. F. DAVIS ENGINEERING INC.
530 LA GONDA WAY, SUITE E
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
KEY PLAN
C
BUILDING 19
BUILDING 20
02/25/2020
2/24/2020 3:26:28 PMH:\REVIT USER FILES\2018\CHRONIC DIALYSIS FINAL STAMPED SUBMITTAL - REV 2 - V2018_RonKorte1120.rvt
CHRONIC DIALYSIS AND
SLEEP PROGRAM
D.DIMAT
AE201C
ARCHITECTURAL REFLECTED
CEILING PLAN - RENOVATION C
J.ROBERTS
612-502
D.DIMAT
1/8" = 1'-0"AE201C
1 RENOVATION C REFLECTED CEILING PLAN PROJECT
NORTH
RIDGE
V A
L L E
Y
V A
L L E
Y
R
ID
G E
SLOPE
1/4" PER FT TYP
MECH
UNIT
JK
7' - 8" 7' - 4" 7' - 8"
SLOPE
AE500A
12.9
AE500A
V A
L L E
Y V
A L L E
Y
HL
1/4" PER FT TYP
RIDGE
AE503
4' - 0"
10' - 0"
10' - 0"
1. CONTRACTOR SHALL FIELD VERIFY (E) DIMENSIONS AND
CONDITIONS BEFORE STARTING WORK.
2. ALL ROOF OR WALL OPENINGS MADE DURING CONSTRUCTION
UNDER THIS CONTRACT SHALL NOT BE LEFT UNPROTECTED
FROM RAIN, MOISTURE, WIND, DUST AND ALL OUTSIDE
ELEMENTS.
3. CONTRACTOR SHALL PROVIDE A COMPLETE WATERTIGHT
EXTERIOR BUILDING ENVELOPE SYSTEM FREE OF AIR AND
WATER LEAKS.
4. THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTING A
WATERTIGHT FACILITY USING THE MEANS AND METHODS
ESTABLISHED BY THE NATIONAL FENESTRATION RATING
COUNCIL (NFRC), THE NATIONAL ROOFING CONTRACTOR'S
ASSOCIATION, WESTERN STATES ROOFING CONTRACTOR'S
ASSOCIATION AND ANY ADDITIONAL STANDARD PRACTICES,
CODES AND REQUIREMENTS AS NECESSARY TO ENSURE A
WATERTIGHT FACILITY FREE OF ANY LEAKS. ANY DETAILS
PROVIDED HEREIN ARE PROVIDED FOR GENERAL GUIDANCE
TO CONVEY THE INTENTION OF THE DESIGN, AND DOES NOT
ALLEVIATE THE CONTRACTOR FROM THE RESPONSIBILITY TO
PROVIDE A COMPLETELY WATERTIGHT FACILITY. THE
CONTRACTOR SHALL PERFORM WATER TESTS TO
DEMONSTRATE TO THE SATISFACTION OF THE CONTRACTING
OFFICER THAT THE BUILDING DOES NOT LEAK. ANY DEFECTS
OR LEAKS SHALL BE IMMEDIATELY REPAIRED AT THE
CONTRACTOR'S EXPENSE.
5. SEE SHEETS AE/503 FOR TYPICAL ROOFING DETAILS.
GENERAL NOTES
SHEET NOTES
1 PARAPET WITH COMPOSITE ALUM. COPING - TYP. U.O.N.
2 ROOF DRAIN AND OVERFLOW DRAIN TYP.
3 SINGLE-PLY TPO ROOFING
4 AHU
5 METAL LOUVER SHADE
6 WALKWAY PADS
7 METAL ROOF ACCESS LADDER
8 EXHAUST FAN
RIDGE
CRICKET
SLOPE DOWN 1/4" : 12"
WALKWAY PADS
LEGEND
R
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C T
PROJECT
NORTH
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of
VA MARTINEZ CAMPUS , CA
19 & 20K. F. DAVIS ENGINEERING INC.
530 LA GONDA WAY, SUITE E
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
KEY PLAN
A
BUILDING 19
BUILDING 20
02/25/2020
2/24/2020 3:26:30 PMH:\REVIT USER FILES\2018\CHRONIC DIALYSIS FINAL STAMPED SUBMITTAL - REV 2 - V2018_RonKorte1120.rvt
CHRONIC DIALYSIS AND
SLEEP PROGRAM
D.DIMAT
AE300A
ARCHITECTURAL ROOF PLAN -
ADDITION A
J.ROBERTS
612-502
D.DIMAT
1/4" = 1'-0"AE300A
1 ADDITION A ROOF PLAN
PROJECT
NORTH
.E
.C
F.E.C.
N
N
N N
NN
N N
N N
1 2 3 4 6 7
C
E
F
G
AE500B
AE500B
4 3
5 7
2.9
B
A
3.5 6.3 6.4
B.8
C.8
D
F.8
4.7
AE503
AE503
8.1 9 10
6' - 0" 4' - 3" 20' - 7" 4' - 3" 24' - 4" 4' - 3" 23' - 9" 4' - 3" 24' - 4" 4' - 3" 22' - 11" 4' - 3" 6' - 0"
6' - 0" 4' - 3" 42' - 11" 1' - 5"
33' - 11"
1' - 5" 26' - 1" 4' - 3" 22' - 11" 4' - 3" 6' - 0"
136' - 11"
AE503
AE504
8 8.5
AE500.1B
AE500.1B
9 10
R
VV
R
VV
R
H
V
R
V
R
V
V
R
R
R
R
VV
R
V
V
V
V
R
V H
R
VV
R
VV
R
H
R
V
V
R
V
R
V
R
V
V
R
R
V
V
RR
V
V
R
V
V
H
V
V
V
V
R
V
V
V
V
V
V
V
V
V
V
V
V
R
R
5' - 2"
1' - 5"
1' - 4"
8' - 4"
1' - 4"
136' - 11"
1. CONTRACTOR SHALL FIELD VERIFY (E) DIMENSIONS AND
CONDITIONS BEFORE STARTING WORK.
2. ALL ROOF OR WALL OPENINGS MADE DURING CONSTRUCTION
UNDER THIS CONTRACT SHALL NOT BE LEFT UNPROTECTED
FROM RAIN, MOISTURE, WIND, DUST AND ALL OUTSIDE
ELEMENTS.
3. CONTRACTOR SHALL PROVIDE A COMPLETE WATERTIGHT
EXTERIOR BUILDING ENVELOPE SYSTEM FREE OF AIR AND
WATER LEAKS.
4. THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTING A
WATERTIGHT FACILITY USING THE MEANS AND METHODS
ESTABLISHED BY THE NATIONAL FENESTRATION RATING
COUNCIL (NFRC), THE NATIONAL ROOFING CONTRACTOR'S
ASSOCIATION, WESTERN STATES ROOFING CONTRACTOR'S
ASSOCIATION AND ANY ADDITIONAL STANDARD PRACTICES,
CODES AND REQUIREMENTS AS NECESSARY TO ENSURE A
WATERTIGHT FACILITY FREE OF ANY LEAKS. ANY DETAILS
PROVIDED HEREIN ARE PROVIDED FOR GENERAL GUIDANCE
TO CONVEY THE INTENTION OF THE DESIGN, AND DOES NOT
ALLEVIATE THE CONTRACTOR FROM THE RESPONSIBILITY TO
PROVIDE A COMPLETELY WATERTIGHT FACILITY. THE
CONTRACTOR SHALL PERFORM WATER TESTS TO
DEMONSTRATE TO THE SATISFACTION OF THE CONTRACTING
OFFICER THAT THE BUILDING DOES NOT LEAK. ANY DEFECTS
OR LEAKS SHALL BE IMMEDIATELY REPAIRED AT THE
CONTRACTOR'S EXPENSE.
5. SEE SHEETS AE/503 FOR TYPICAL ROOFING DETAILS.
GENERAL NOTES
SHEET NOTES
PARAPET WITH ALUM. COPING - TYP. U.O.N.
ROOF DRAIN AND OVERFLOW DRAIN TYP.
SINGLE-PLY TPO ROOFING.
AHU.
STANDING SEAM METAL ROOF.
WALKWAY PADS.
GUTTER WITH DOWNSPOUT.
SLOPING PARAPET.
CUT BACK EXISTING ROOF TO ALLOW FOR INSTALLATION OF
SEISMIC JOINT COVER.
PROVIDE WALL TO ROOF SEISMIC JOINT COVER.
CRICKET
SLOPE DOWN 1/4" : 12"
WALKWAY PADS
ROOF HATCH
RIDGE
VALLEY
HIP
LEGEND
R
V
H
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C T
PROJECT
NORTH
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of
VA MARTINEZ CAMPUS , CA
19 & 20K. F. DAVIS ENGINEERING INC.
530 LA GONDA WAY, SUITE E
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
KEY PLAN
B
BUILDING 19
BUILDING 20
02/25/2020
2/24/2020 3:26:33 PMH:\REVIT USER FILES\2018\CHRONIC DIALYSIS FINAL STAMPED SUBMITTAL - REV 2 - V2018_RonKorte1120.rvt
CHRONIC DIALYSIS AND
SLEEP PROGRAM
D.DIMAT
AE300B
ARCHITECTURAL ROOF PLAN -
ADDITION B
J.ROBERTS
612-502
D.DIMAT
1/8" = 1'-0"AE300B
1 ADDITION B ROOF PLAN PROJECT
NORTH
T.O.SLAB
0"
T.O. PARAPET
15' - 6"
T.O. ROOF PLAN
12' - 0"
CEILING LINE
8' - 0"
JK
HL
T.O.SLAB
0"
T.O. PARAPET
15' - 6"
T.O. ROOF PLAN
12' - 0"
CEILING LINE
8' - 0"
12.9
AE501
T.O.SLAB
0"
T.O. PARAPET
15' - 6"
T.O. ROOF PLAN
12' - 0"
CEILING LINE
8' - 0"
11 12
GRADE LINE
-6"
12.9
4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0"
AE501
T.O.SLAB
0"
T.O. PARAPET
15' - 6"
T.O. ROOF PLAN
12' - 0"
CEILING LINE
8' - 0"
J K
H L
1. CONTRACTOR SHALL FIELD VERIFY (E) DIMENSIONS AND
CONDITIONS BEFORE STARTING WORK.
2. ALL ROOF OR WALL OPENINGS MADE DURING CONSTRUCTION
UNDER THIS CONTRACT SHALL NOT BE LEFT UNPROTECTED
FROM RAIN, MOISTURE, WIND, DUST AND ALL OUTSIDE
ELEMENTS.
3. CONTRACTOR SHALL PROVIDE A COMPLETE WATERTIGHT
EXTERIOR BUILDING ENVELOPE SYSTEM FREE OF AIR AND
WATER LEAKS.
4. THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTING A
WATERTIGHT FACILITY USING THE MEANS AND METHODS
ESTABLISHED BY THE NATIONAL FENESTRATION RATING
COUNCIL (NFRC), THE NATIONAL ROOFING CONTRACTOR'S
ASSOCIATION, WESTERN STATES ROOFING CONTRACTOR'S
ASSOCIATION AND ANY ADDITIONAL STANDARD PRACTICES,
CODES AND REQUIREMENTS AS NECESSARY TO ENSURE A
WATERTIGHT FACILITY FREE OF ANY LEAKS. ANY DETAILS
PROVIDED HEREIN ARE PROVIDED FOR GENERAL GUIDANCE
TO CONVEY THE INTENTION OF THE DESIGN, AND DOES NOT
ALLEVIATE THE CONTRACTOR FROM THE RESPONSIBILITY TO
PROVIDE A COMPLETELY WATERTIGHT FACILITY. THE
CONTRACTOR SHALL PERFORM WATER TESTS TO
DEMONSTRATE TO THE SATISFACTION OF THE CONTRACTING
OFFICER THAT THE BUILDING DOES NOT LEAK. ANY DEFECTS
OR LEAKS SHALL BE IMMEDIATELY REPAIRED AT THE
CONTRACTOR'S EXPENSE.
5. SEE SHEETS AE/503 FOR TYPICAL ROOFING DETAILS.
GENERAL NOTES
SHEET NOTES
METAL PARAPET COPING
EXPANSION / CONTROL JOINT
ALUMINUM COMPOSITE PANEL, MATCH
ADJACENT BLDG 1 COLOR PATTERN
ALUMINUM WINDOWS
MECHANICAL UNIT
STORE FRONT DOOR UNIT
LOUVERED METAL OVERHANG " VESTIS
SYSTEMS" ALUMINIUM LOUVERED
SUNSHADE OR APPROVED VA EQUAL.
METAL ROOF ACCESS LADDER
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C T
PROJECT
NORTH
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of
VA MARTINEZ CAMPUS , CA
19 & 20K. F. DAVIS ENGINEERING INC.
530 LA GONDA WAY, SUITE E
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
KEY PLAN
A
BUILDING 19
BUILDING 20
02/25/2020
2/24/2020 3:26:37 PMH:\REVIT USER FILES\2018\CHRONIC DIALYSIS FINAL STAMPED SUBMITTAL - REV 2 - V2018_RonKorte1120.rvt
CHRONIC DIALYSIS AND
SLEEP PROGRAM
D.DIMAT
AE400A
ARCHITECTURAL ELEVATIONS -
ADDITION A
J.ROBERTS
612-502
D.DIMAT
1/4" = 1'-0"AE400A
1 ADDITION A NORTHEST
1/4" = 1'-0"AE400A
2 ADDITION A NORTHWEST
1/4" = 1'-0"AE400A
3 ADDITION A SOUTHEST
1/4" = 1'-0"AE400A
4 ADDITION A SOUTHWEST
FIN FLOOR LINE B
123467
TOP OF PLATE B
11' - 0"
B.O. CEILING LINE
9' - 0"
T.O. DECK B
13' - 6"
T.O. PARAPET B
18' - 6"
2.93.56.36.4 4.78.1910 8
14' - 3"
18' - 3"
18' - 9" 18' - 7"
14' - 3"
8.5
FIN FLOOR LINE B
0"
C E F G
TOP OF PLATE B
11' - 0"
B.O. CEILING LINE
9' - 0"
T.O. DECK B
13' - 6"
T.O. PARAPET B
18' - 6"
BA B.8 C.8 D F.8
18' - 4"
FIN FLOOR LINE B
0"
CEFG
TOP OF PLATE B
11' - 0"
B.O. CEILING LINE
9' - 0"
T.O. DECK B
13' - 6"
T.O. PARAPET B
18' - 6"
1 2
B AB.8C.8DF.8
18' - 4"
1. CONTRACTOR SHALL FIELD VERIFY (E) DIMENSIONS AND
CONDITIONS BEFORE STARTING WORK.
2. ALL ROOF OR WALL OPENINGS MADE DURING CONSTRUCTION
UNDER THIS CONTRACT SHALL NOT BE LEFT UNPROTECTED
FROM RAIN, MOISTURE, WIND, DUST AND ALL OUTSIDE
ELEMENTS.
3. CONTRACTOR SHALL PROVIDE A COMPLETE WATERTIGHT
EXTERIOR BUILDING ENVELOPE SYSTEM FREE OF AIR AND
WATER LEAKS.
4. THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTING A
WATERTIGHT FACILITY USING THE MEANS AND METHODS
ESTABLISHED BY THE NATIONAL FENESTRATION RATING
COUNCIL (NFRC), THE NATIONAL ROOFING CONTRACTOR'S
ASSOCIATION, WESTERN STATES ROOFING CONTRACTOR'S
ASSOCIATION AND ANY ADDITIONAL STANDARD PRACTICES,
CODES AND REQUIREMENTS AS NECESSARY TO ENSURE A
WATERTIGHT FACILITY FREE OF ANY LEAKS. ANY DETAILS
PROVIDED HEREIN ARE PROVIDED FOR GENERAL GUIDANCE
TO CONVEY THE INTENTION OF THE DESIGN, AND DOES NOT
ALLEVIATE THE CONTRACTOR FROM THE RESPONSIBILITY TO
PROVIDE A COMPLETELY WATERTIGHT FACILITY. THE
CONTRACTOR SHALL PERFORM WATER TESTS TO
DEMONSTRATE TO THE SATISFACTION OF THE CONTRACTING
OFFICER THAT THE BUILDING DOES NOT LEAK. ANY DEFECTS
OR LEAKS SHALL BE IMMEDIATELY REPAIRED AT THE
CONTRACTOR'S EXPENSE.
5. SEE SHEETS AE/503 FOR TYPICAL ROOFING DETAILS.
GENERAL NOTES
SHEET NOTES
1 METAL ROOF
2 METAL COPING
3 ALUMINUM WINDOWS
4 ALUMINUM LOUVERS
5 MASONRY WAINSCOT
6 METAL DOOR
7 COMPOSITE WOOD FASCIA
8 CEMENT PLASTER SIDING
FIN FLOOR LINE B
0"
1 2 3 4 6 7
TOP OF PLATE B
11' - 0"
B.O. CEILING LINE
9' - 0"
T.O. DECK B
13' - 6"
T.O. PARAPET B
18' - 6"
2.9 3.5 6.3 6.44.7 8.1 9 10
14' - 3"
18' - 7"
17' - 11"
8.5
36' - 7"
Exp._______
#C-23213
08/19
JEF R. ROBERTSS
TA
TE
OF CA L I FORN
IA
R E
G
I S T ER E D A RC H
I T E
C T
PROJECT
NORTH
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h ts i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t o n e i n c h o n e f o o t
VA FORM 08-6231
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title: Project Title: Project Number:
Building Number:
Drawing Number:Location
Date Checked Drawn
Office of Construction and Facilities Management
Dwg. of
VA MARTINEZ CAMPUS , CA
19 & 20K. F. DAVIS ENGINEERING INC.
530 LA GONDA WAY, SUITE E
DANVILLE, CA 94526
WWW.KFDE.US
(925) 743-8884
KEY PLAN
B
BUILDING 19
BUILDING 20
02/25/2020
2/24/2020 3:26:42 PMH:\REVIT USER FILES\2018\CHRONIC DIALYSIS FINAL STAMPED SUBMITTAL - REV 2 - V2018_RonKorte1120.rvt
CHRONIC DIALYSIS AND
SLEEP PROGRAM
D.DIMAT
AE400B
ARCHITECTURAL ELEVATIONS -
ADDITION B
J.ROBERTS
612-502
D.DIMAT
1/8" = 1'-0"AE400B
1 ADDITION B NORTH ELEVATION
1/8" = 1'-0"AE400B
3 ADDITION B WEST ELEVATION
1/8" = 1'-0"AE400B
4 ADDITION B EAST ELEVATION
1/8" = 1'-0"AE400B
2 ADDITION B SOUTH ELEVATION
T.O.SLAB
T.O. PARAPET
15' - 6"
CEILING LINE
8' - 0"
JK
T.O. STEEL
11' - 6"
S O
F F
IT
C E
IL
IN
G
HL
T.O.SLAB
0"
T.O. PARAPET
15' - 6"
CEILING LINE
8' - 0"
11 12
T.O. STEEL
11' - 6"
12.9
14 10 11 12
AE503
AE504
SHEET NOTES
METAL COPING
PRE-FABRICATED FINISH PANEL
METAL STUD FRAMING
STRUCTURAL STEEL FRAME
ALUMINUM WINDOWS
CONCRETE FOUNDATION/SLAB
5/8" TYPE "X" GYP. BD.
SUSPENDED GYP. BD. SOFFIT
SUSPENDED…