This document is an architectural floor plan for a VA Outpatient Clinic located at 35 State Hospital Drive, Bangor, Maine 04401. The plan, prepared by Welman Architects Inc. and dated March 19, 2010 (Project No. 28112), depicts a comprehensive medical facility layout at 1/8" = 1'-0" scale.
The facility includes multiple specialized clinical areas organized by department: primary care and urgent care sections with waiting areas, dental and oral surgery units with imaging capabilities, physical therapy and rehabilitation spaces with treatment and exercise rooms, ophthalmology/optometry services with multiple exam lanes and visual field testing rooms, audio services with sound booths and testing offices, obstetrics/gynecology exam and ultrasound facilities, imaging departments, laboratory and blood draw stations, pharmacy services, and medical records. Administrative and support functions include registration/check-in, information desk, offices for social workers, nursing staff, clinic managers, and various conference/educational spaces. Infrastructure areas encompass mechanical and electrical rooms, storage facilities (including hazardous material storage), janitorial spaces, locker rooms, and utility areas. The facility provides multiple patient amenities including waiting areas with specified seating capacities, restrooms distributed throughout, and accessibility features. General construction notes specify gypsum board partitions, moisture-resistant materials in plumbing areas, fire-rated assemblies, corner guards in corridors, ADA compliance requirements, and coordination with mechanical, electrical, and plumbing trades. The revision history indicates design development reviews completed between March and May 2010, including VA and city submissions.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5402/5405
20AMPS
445 444
2 22
2 22
1 11 1
1 11 1
1 11 1 1 1 1 1
1 11 1 1 1 1 1 1 1 1 1
1 1
1 11
11 1
1 11 1
11 11
1 11
11 1
B B
C C
D D
E E
F F
G G
H H
F.8'
1010.2 1204.1
1C
.1
1101D.1
1B
.1
1203.1
0.1
1202.1
1201.1
1B
.1
1316.1
1317.1
1320.1
1314.1
1313.1
8.1
7.1
6.1
1312.1 1305.1
3.1
5.1
9.1
1318.1
1.1
1301.1
1302.1
1304.1
1409.1
1410.1
1411.1
1412.1
1414.1
5.1
3.1
1403.1
1406.1
8.1
1408A.1
1407.1
1405.1
1404.1
1401.1
1501.1
1502.1
1507.1
4.1
3.1
2.1
1506.1
1504.1
5.1
4.1
2.1
1.1
3.1
2.1
3.1
0.1
1500.2
1627.1
1631.1
1700.1
5.1
3.1
1619.1
1618.1
1617.1
1616.1
1615.1
1614.1
1609.1
1607.1
1605.1
1604.1
1710.1
0.1
1.1
1608.1
1629.1
1632.1
3.1
1606.1
2.1
1.1
1704.1
8.1
9.1
8.1
1809.1
1810.1
7.1
6.1
4.1
3.1
1905B.1
3.1
AUDIO SOUND
BOOTH
AUDIO SOUND
BOOTH
AUDIO OFF.
PAT. TLT.
PHYS. OFFICE
PHYS. EXTEND
ST. TOILET
EXAM
AUDIO OFFICE
AUDIO OFFICE
CAMERA
DISPENS.
EXAM
MECH.
1408A
HYGIENE
ORAL EXAM
VISUAL FIELDS
EXAM-EYE
LANE
DENTAL
IMAGING
EXAM-EYE
LANE
PATIENT
TOILET
SOIL. SPD
CART
SEC./REC.
ORAL EXAM
ORAL EXAM
STORAGE
ORAL SURG.
CLEAN
INSTRUMENTS
GROUP
THERAPY
1306OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
1305 GROUP
THERAPY
DENTAL/
PROSTH. LAB
RECOV. RM.
OFFICE
HEALTH TECH
OFF. ADMIN
ASST.
PASSAGE
1416C
PASSAGE
1321A
PASSAGE
PASSAGE
1321B
UTIL/STG
WAITING
PATIENT TLT
PATIENT TLT
OFFICE
OFFICE
PASSAGE
1321C
PASSAGE
1416A
PASSAGE
1416B
PASSAGE
PASSAGE
PASSAGE
1521A
PASSAGE
1633D
CRASH CT.
PAT. TLT
EXAM
EXAM
EXAM
EXAM
SPECIALTY
WAITING
PASSAGE
1633C
STORAGE
CLEAN UTIL.
SOIL UTIL.
PHYS. OFF.
PHYS. EXTEND.
PHYS. OFFICE
EXAM
EXAM
EXAM
EXAM/GYN.
ST. TOILET
CLINIC
MANAGER
URG. CARE
OBSVER/TREAT
EXAM
READING
PHYS. OFFICE
IMAGING
PASSAGE
TECH. OFF.
ULTRASOUND
PROCEDURE
HAC.
PAT. TLT
MED RECORDS
EMS SUPPLY
STERILE / NON
STERILE STOR
VESTIBULE
1801 CL LIN.
SOIL LIN.
IT/BIO MED
INFECT WASTE
1811 CL REC. / BULK
STOR
MAS STOR.,
SPLY, EQ.
PASSAGE
MEN'S TLT.
1021COMP/PEN
TELEHEALTH
PATIENT
TOILET
1101C
HYDRO THER.
1101D
OFFICE, SOC.
WKR.
OFFICE NURSE
TREATMENT/EXERCISE
WAIT
OFFICE NURSE
OFFICE NURSE
VOL/ESCORT
WAIT
VESTIBULE
STOR.
1101B
PASSAGE
PASSAGE
1633A
5.8'
7.8'
A2.1
A2.1
A2.1
A2.1
A4.2
NURSE
PASSAGE
1'
- 4
8"
0"
0"
8"
6"
8" 1'
- 4
1' - 4" 29' - 8" 30' - 0" 30' - 0" 30' - 2" 29' - 10" 29' - 8" 1' - 4"
1' - 4" 29' - 8" 30' - 0" 30' - 0" 30' - 2" 29' - 10" 29' - 8" 1' - 4"
1'
- 4
8"
0"
0"
2"
8"
1'
- 4
STAFF TLT
PASSAGE
1633B
AUDIO SUPPLY
50'
- 0
1' - 4"
23'
- 8
23'
- 8
1' - 4"
34'
- 0
VESTIBULE
AMBULANCE BAY
LOADING AREA
A4.3
4.1
3.1
1311.1
1309.1131 0.1
SOC. WKR.
OFFICE
OFFICE
6.2
PATIENT
TOILET
USC/TOILET
2.2
3.1
2.1
1.1
6.1
5.1
1628.1
MEDS
1630.1
6.1
BLOOD DRAW
BLOOD DRAW
CONSULT #2
STORAGE
1008A
LAB
HAZ STOR
1204A
P.T. WAIT
MEN'S TLT.
WOMEN'S TLT.
OPEN OFFICE
EXAM-EYE
LANE
EXAM-EYE
LANE
1509 OFFICE
PRIMARY CARE
WAITING
WOMEN'S TLT.
NURSE
5.1
E.8'
1' - 4"
23' - 10"
3.9
A
4.7 5.6 6.6 2.5'
1.5'
C.3'
C.5'
D.5'
7' - 6"
17' - 0" 0.5'
3.5'
15'
- 0
15'
- 0
1.3'
2.3'
8' - 9"
13'
- 1
0"
8' - 9"
18' - 0"12' - 6"17' - 4"9' - 0"
A4.1
A4.1
A4.1
A4.1
CORRIDOR
PHARMACY /
TRANS
CONSULT #1
PASSAGE
1205A
28' - 8" 1' - 4"
1' - 4"
1' - 4"
1204A.1
1.2
NURSE
WAITING
0"
0"
7'
- 0
0"
0"
0"
0"
0"
7'
- 0
7'
- 0
7'
- 0
6'
- 0
0"
12' - 5 1/2" 6' - 0" 13' - 7" 13' - 0"
0"
6"
8'
- 0
8' - 5" 12' - 10" 20' - 0"
14' - 8"
6'
- 5
3"
0" 7'
- 7
6'
- 5
4'
- 7
6' - 5" 11' - 9 1/2" 11' - 9 1/2" 6' - 5"
0" 6'
- 0
0"
0"
9 1 /2"
6'
- 5
9 1
/2"
9 1
/2" 6'
- 5
9 1 /2"
0"
5' - 10 1/2" 5' - 11"
2'
- 0
6' - 0"
11' - 10" 10' - 10" 12' - 9"
11' - 8" 9' - 0" 9' - 0" 9' - 0" 21' - 0" 35' - 2 1/2" 11' - 9 1/2" 12' - 5" 8' - 7"
6'
- 4
D.4
C.4
2"
2"
0"
0"
8"
0"
0"
0"
6.8'
6' - 5" 11' - 9 1/2" 11' - 9 1/2" 6' - 5" 11' - 9 1/2" 11' - 9 1/2" 6' - 5" 10' - 7" 6' - 5"
6'
- 5
8'
- 9 1/
2" 8'
- 9 1/
2" 6'
- 5
5'
- 9
1/ 2"
9'
- 0
1/ 2"
8'
- 5
1/ 2"
7" 6'
- 0
8'
- 0
11' - 9 1/2" 7' - 0" 12' - 0" 8' - 9 1/2" 8' - 9 1/2" 8' - 5" 5' - 5" 10' - 7"
2 1 /2"
0"
0 1
/2"
0"
0"
6'
- 0
6'
- 0
9'
- 8
3 1 /2"
3 1 /2"
6'
- 5
6'
- 0
9'
- 0
9'
- 0
0"
0" 6'
- 8
0"
0"
0"
0"
8"
5' - 5"
6' - 0" 6' - 0"
0" 4'
- 1 0"
7'
- 1
0 3 /8"
7"
1/
2"
5'
- 1
1 1 /2"
6'
- 0
5' - 0"
10' - 10" 10' - 10" 8' - 0" 8' - 0" 6' - 0"
5' - 5"
1" 3'
- 0
8' - 0"
7'
- 1
1"
0 1
/4"
5' - 5"
9' - 1 1/8" 2' - 0" 8' - 11 7/8" 1' - 10"
3'
- 0
135.00
3' - 0"
135.00
5'
- 8
6' - 8"
11' - 5 1/2"
11' - 10"
21'
- 3
8' - 5"
6' - 5"
11'
- 3
13'
- 4
1' - 4"
7' - 0"
7' - 0"
6' - 2"
25' - 4"
C.2
C.6
8'
- 0
0"
7'
- 0
2' - 0" 4' - 0" 15' - 8" 4' - 0" 27' - 4" 7' - 4" 37' - 8" 6' - 4"
1.1
4' - 0"
1' - 2" 10"
4' - 0"4' - 0"
1' - 0" 1' - 0"
4' - 0"2' - 0" 4' - 0" 8' - 0" 4' - 0" 8' - 0" 4' - 0"
1' - 0" 1' - 0"
4' - 0" 8' - 0" 4' - 0" 8' - 0" 4' - 0"
1' - 0" 1' - 0"
4' - 0" 8' - 0" 4' - 0" 8' - 0" 20' - 0"
2'
- 0
4'
- 0
8" 4'
- 0
5'
- 4
4'
- 0
2'
- 0
4'
- 0
8'
- 0
4'
- 0
8'
- 0
4'
- 0
2'
- 0
5'
- 8
4'
- 0
8'
- 0
4'
- 0
0"
1'
- 4
5 1 /2"
6'
- 5
12' - 11 1/2" 6' - 5" 8' - 7"
16' - 4" 23' - 0"
6' - 5"
6' - 5" 11' - 9 1/2" 11' - 9 1/2"
11' - 0" 9' - 6 1/2"
29' - 0"
6' - 4"
8.1
AUDIO
OFFICE/TECH.
6' - 8"
A4.2
A4.2
A4.2
A4.3
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
(TYP.)
VERIFY BOOTH SIZE
1 1 1 1 1 1 1 1 1
2 2 2
1000.3
1000.1
1.1
2.1
1020.1
0.2
1521A.1
1025.1
4'
- 0
8'
- 0
4'
- 0
"10
1'
- 2
4'
- 0
8'
- 0
4'
- 0
8'
- 0
4'
- 0
1'
- 0
1'
- 0
4'
- 0
8'
- 0
4'
- 0
8'
- 0
4'
- 0
1'
- 0
1'
- 0
4'
- 0
9' - 4"
4' - 0"
2' - 0"
4' - 0"
5' - 4"
1' - 4" 4' -
0"
10'
- 8
8' - 0"
10' - 5" 10' - 5"
A4.2
A3.1
1905.1
1901.1
1902.1
CONFERENCE/
CLASS/ MULTI
PURPOSE
TELE/D.F.
PASSAGE
VESTIBULE
PASSAGE
1024A
TELE/DATA
MEN'S LOCKER
WOMEN'S
LOCKER
MECH
ELECT.
1905B
DIST.
1905A
9.1
11' - 0"
5"
8"
6'
- 0
6'
- 8
6'
- 6
0"
14' - 3" 12' - 0 5/8" 11' - 0" 14' - 2 7/8"
11' - 7 1/2"
1019.1
8.1
1005.1
1005C.1
1005B.1
5A
.1
1802.1
1811.1
1620.1
5.1
AUDIO OFF.
1517151
7.1
6.2
1101A.1
PT OFFICE
1101A
3.1
2.1
0.1
9.1
DILATE/
SUBWAIT
ROUTE
0.1
1.1
8A
.1
MAINE VET
OFFICE
1005A
MAINE VET
CONFERENCE
1005B
MAINE VET
SECRETARY
MAINE VET
STORAGE
1005C
MED RECORDS
MAS OFFICE
1018REGISTRATION
/ CHECK IN
INFORMATION
1007 CHECK OUT
EXAM
1402.1
1' - 0"
WORK
WORK
PRIMARY
CARE/XRAY
WAITING
21 SEATS
13 SEATS
8 SEATS
18 SEATS
9'
- 6
9'
- 6
1503.1
1508.1
7' - 0" 7' - 0" 13' - 7" 7' - 3 7/8"
10' - 1 1/4"
2A
.1
IT / CL
1902A
29 SEATS
22 SEATS
EYEWASH
6 SEATS
7'
- 0
7'
- 5
3"
6"
5"
2' - 5" 14' - 0" 9' - 4 7/8" 9' - 4 7/8" 2' - 10 3/4"
9'
- 0
"135.00
11' - 6 1/2"
11' - 0"
7"
8' - 5"
9'
- 1
1" 9'
- 3
3'
- 0
1/ 2"
E.4
2'
- 0
7' -
0"
1/
2"
1905A.1
5.5
F.3
9'
- 0
7'
- 1 0"
6.1
1705.1 1705.2
1708.2
DRESS
DRESS
1702.1
STORAGE
1701.1
SUB WAIT
0.2
0.1
8' - 0"
7' - 0"
2'
- 0
8.1
5' - 6"
1009.2
0.1
EDUCATIONAL
CONF ROOM
TELEPHONE
ASSISTANCE
PROGRAM
STORAGE
6'
- 7
5/ 8"
9'
- 3
3/ 4"
1'
- 0
1'
- 0
5'
- 5
2 2
CLR12'
- 0
9 9
2 22222222222
1.2
A5.1
A5.1
5 5
MYHEVET
C.7
C.7
M.1 M.1
C.7
C.7
C.7
C.7
R.1
R.1
R.1 R.1
R.2R.2
R.2R.2
R.2 R.1R.1
R.1R.1
R.1
R.1R.1
R.1R.1
R.1R.1 R.1
R.1
R.1
5.3
6.2
PASSAGE
1712A
HAC
1707.1
E.6
4.6
A1.2
59' - 4"
A6.2
A6.2
A6.2
A7.1
A7.24
A7.1
A7.1
A7.1
TYP.
A7.1
A7.1
A7.1
A7.1
A7.1
A7.1
TYP.
A7.2
A7.1
A7.1
A7.1
A7.2
A7.3
A7.2
A7.3
A7.1
8'
- 0
1/ 2"
5'
- 9
1/ 2"
A7.2
A7.2
TYP.
A7.2
A7.2
A7.1
A7.2
A7.2 15 17
22 22
BL-1
BL-1
BL-1
BL-1
BL-1
R.1
FD
R.1R.1
R.1
R.1
A7.3
A7.3
FD
FD
BL-1
PASSAGE
1023A
PASSAGE
1024B
PASSAGE
1024C
PASSAGE
1024D
PASSAGE
1024B
PASSAGE
1024C
10'
- 2
13'
- 8
" R .O.
10'
- 2
A5.1
TYP.
3' - 0"
1025.2
OPP
OPP
1000.2
1711.1
A4.3
6'
- 4
4'
- 4
1711.2
A7.19A
1001.1
A4.1
1000.6
1000.4
1000.5
1 1
A5.1
11' - 9 7/8" 7' - 10 1/4"
7' - 6"
7'
- 6
6'
- 0
1/ 4"
1812.1
C.4
C.42'
- 8
1' - 8"
D.F.
F.4
F.4
27 27
27 27
2727 27
27 27
272727
9 9
A6.1
TELE/DATA
1901A
1901A.1
2'
- 0
182' - 0"
2'
- 0
182' - 0"
NEG.
PRESSURE
NEG.
PRESSURE
STUD FRAMING EXTENDED TO STRUCTURE ABOVE SHALL HAVE 3" x 3 5/8" GALVANIZED STUD TRACK AT TOP.
STUD FRAMING SHALL BE 3/4" FROM TOP OF TRACK AND HAVE NO MECHANICAL FASTENING TO ALLOW FOR 3/4"
DEFLECTION
VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, AND ALIGNMENT OF WALLS. BRING ANY DISCREPANCIES TO
THE ARCHITECTS ATTENTION PRIOR TO START OF FABRICATION / CONSTRUCTION
A) PROVIDE 5/8" TYPE "X" GYPSUM BOARD AT ALL LOCATIONS UNLESS OTHERWISE NOTED.
B) PROVIDE 5/8" TYPE "X" MOISTURE RESISTANT GYPSUM BOARD AT PLUMBING PARTITIONS AND PARTITION
FACE WITHIN 6'-0" OF ALL PLUMBING FIXTURES
C) PROVIDE CEMENT PLASTER BOARD AS BACK-UP AT ALL CERAMIC WALL TILE LOCATIONS
HOLD 5/8" CLEARANCE BETWEEN FLOOR AND GYPSUM BOARD. FILL GAP BETWEEN BOTTOM EDGE OF GYPSUM BOARD AND FLOOR WITH MOISTURE RESISTANT MASTIC CAULKING. STRIKE COMPOUND SMOOTH AND FLUSH
WITH FACE OF PARTITION. REMOVE EXCESS MASTIC CAULKING FROM PARTITION AND FLOOR.
ALL VINYL OR FABRIC WALL COVERING AT CORRIDOR CORNER LOCATIONS TO RECEIVE A CLEAR PLASTIC CORNER GUARD TO A HEIGHT OF 8'-0" A.F.F.. ( IPC INSTITUTIONAL PRODUCTS CORP. #8118 OR APPROVED EQUAL
) UNLESS OTHER PROTECTION IS SPECIFIED
CHANGES IN FLOOR MATERIALS SHALL BE LOCATED AT THE CENTERLINE OF DOORS UNLESS NOTED
OTHERWISE
VERIFY LOCATION OF ACCESS PANELS WITH MECHANICAL AND ELECTRICAL DRAWINGS FOR ACCESS TO
MECHANICAL AND ELECTRICAL ITEMS
SEAL PENETRATIONS IN FIRE RATED ASSEMBLIES AND SMOKE BARRIERS TO MEET REQUIRED RATINGS. UTILIZE
UL APPROVED METHODS
PROVIDE 16 GAUGE SHEET METAL BANDING AS REQUIRED TO SUPPORT ALL CABINETS, SHELVES, BUILT-INS, EQUIPMENT OR ACCESSORIES. COORDINATE WITH VENDOR DOCUMENTS WHERE SUCH CONDITIONS APPLY
ALL WALLS TO BE TYPE C.1 UNLESS NOTED OTHERWISE
NOTIFY THE ARCHITECT & VA PROJECT MANAGER IF ELECTRICAL / COMMUNICATION / HVAC / PLUMBING / ITEMS DEPICTED CONFLICT WITH ADA REQUIREMENTS OR INDUSTRY STANDARDS PRIOR TO INSTALLATION.
NOTE: ALL DEVICES AND CONTROLS TO BE INSTALLED WITHIN A MAXIMUM OF 4" OF EACH OTHER
HORIZONTALLY
( NOT 16" O.C. ) AND ALIGN THE BOTTOMS OF EACH ITEM. IN THE VERTICAL POSITION ALIGN THE ITEMS ON
CENTERLINES
DURING CONSTRUCTION , AREA SHALL BE KEPT BROOM CLEAN AND FREE OF DEBRIS.
LIGHTING, EXIT LIGHTING INFORMATION, ELECTRICAL, DATA AND TELEPHONE INFORMATION SHOWN ARE FOR ELECTRICAL CONTRACTORS REFERENCE ONLY. CONTRACTOR SHALL ENSURE COORDINATION OF ELECTRICAL ITEMS WITH BUILDING CONSTRUCTION AND EQUIPMENT AND SHALL OBTAIN THE NEEDED INFORMATION TO
PROVIDE A COMPLETE AND WORKING INSTALLATION
CONSTRUCTION SHALL BE IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL CODES.
PROVIDE C.1 PARTITION TYPE AROUND ALL TOILET ROOMS AND ADJUST WALL THICKNESS FOR PLUMBING. USE MOSITURE RESISTANT GYPSUM WALL BOARD & GALVANIZED METAL STUDS WITHIN 6'-0" OF ALL PLUMBING
FIXTURES.
PROVIDE "HANDILAV-GUARD" INSULATION KITS BY TRUEBRO INC. AT ALL ADA ACCESSIBLE LAVATORIES.
PROVIDE GFI ELECTRICAL OUTLETS AT LOCATIONS REQUIRED BY CODE.
SALVAGED MATERIAL SHALL BE CLEANED AND RETURNED TO THE OWNER AS DIRECTED.
PROVIDE CONTINUOUS VAPOR BARRIER (ON WARM SIDE OF WALL) ALONG ENTIRE PERIMETER OF EXTERIOR
WALL FROM FLOOR TO ROOF DECK. ALL PENETRATIONS TO BE SEALED.
ALL PENETRATIONS OF EXTERIOR WALL ARE TO BE MADE AIR TIGHT.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
GENERAL NOTES
CODED NOTES
PROVIDE BASE BUILDING STANDARD FULLY RECESSED FIRE EXTINGUISHER AND CABINET. MOUNT PER BASE BUILDING SPECIFICATIONS NOT TO EXCEED 25" A.F.F. TO FLOOR OF CABINET. USE 6" METAL STUDS
AT CABINET LOCATIONS.
PROVIDE BASE BUILDING STANDARD BLINDS AND SILL. (TYPICAL)
THIS ROOM TO RECEIVE LEAD SHIELDING 1/16" MIN. THICK. COORDINATE FINAL REQUIREMENTS WITH
PHYSICIST REPORT.
PROVIDE WALL MOUNTED TV BRACKET. COORDINATE MOUNTING HEIGHT WITH OWNER.
PROVIDE CARD ACCESS AT THIS DOOR
PROVIDE 4'-0" x 4'-0" PLYWOOD MOUNTED AT 3'-0" A.F.F.
24" x 24" FLOOR MOUNTED SERVICE SINK. REFER TO PLUMBING DRAWINGS.
PROVIDE EYE WASH STATION THIS LOCATION
OWNER PROVIDED FURNITURE EQUIPMENT
PROVIDE 5 HIGH SHELVING - SEE DETAIL 12/A5.1
ROUGH IN PLUMBING - REFER TO PLUMBING DRAWINGS.
EMERGENCY SHOWER/EYEWASH - REFER TO PLUMBING DRAWINGS.
CEILING MOUNTED PROJECTION SCREEN. COORDINATE LOCATION WITH OWNER.
2 HIGH ADJUSTABLE SHELVING.
GAS METER LOCATION
CEILING MOUNTED PROJECTOR. COORDINATE LOCATION WITH OWNER.
BULLET PROOF GLASS
PROVIDE FIRE CAULK WHERE RATED PARTITION MEETS COLUMN AND ADHERE 5/8" TYPE "X" GYP. BD.
DIRECTLY TO REMAINING EXPOSED COLUMN.
OPENING IN CEILING TO ACCOMODATE "PRECISION LADDERS" PULL DOWN STAIR.
BENCH - REFER TO ELEVATION 13/A7.2
PROVIDE 3 HIGH SHELVING - SEE DETAIL 13/A5.1
48" HIGH HALF WALL - SEE DETAIL 9/A5.1
ACCORDIAN FOLDING PARTITION - SEE DETAILS 16/A5.1 & 12/S401
CONTRACTOR PROVIDED INSTALLED LOCKERS W/ SLOPED TOPS, PROVIDE BLOCKING AS REQ'D - SEE
SPECIFICATION FOR MORE INFO.
FUME HOOD - OWNER PROVIDED, CONTRACTOR INSTALLED
PROVIDE ROUGH IN ONLY FOR SINK
IPC CORNER GUARDS 4'-0" LONG - SEE FINISH LEDGEND FOR TYPE.
PROVIDE HANDRAIL - REFER TO FINISH LEDGEND FOR TYPE.
FIRE ALARM ELECTICAL PANEL - REFER TO ELECTRICAL DWGS.
PROVIDE 4'-0" HEIGHT CONCRETE BOLLARDS
H/L DRINKING FOUNTAINS
PROVIDE SPECIMEN PASS THRU. REFER TO MOUNTING HEIGHTS FOR FURTHER INFO. T 1/A6.1.
21675 LONG VIEW DRIVE
SUITE 500
WAUKESHA, WI 53186
FAX (262) 798.7001
PHONE (262) 798.7000
E-MAIL welman@welmanarch.com
PROJECT NO.
DATE:
REVISION / ISSUES:
SHEET NAME:
SHEET NO:
C COPYRIGHT BY WELMAN
ARCHITECTS INC.
PROJECT:
03.19.2010 FTG/FND SUBMITTAL
CONTRACTOR:
889 E. Johnson Street Fond Du Lac, WI 54936 Phone: 920-924-2900 Fax: 920-924-2910
03.26.2010 Design Development Review I & II
04.02.2010 75% VA Review
04.16.2010 City Submittal
05.21.2010 CB #1
05.21.2010 100% VA Review
35 State Hospital Drive
Bangor, ME 04401
A1.1
FLOOR PLAN
VA
Outpatient
Clinic
03/19/2010
28112
SCALE: 1/8" = 1'-0"1 FLOOR PLAN
PLAN NORTH TRUE NORTH
File details come from the government source that posted it. Updated .