ATTACHMENT 4 - Drawings Vol 1 - Part 2.pdf

PDF 44 MB Posted

Attached to
Y1DA--EHRM Infrastructure Upgrades Construction San Juan Federal contract opportunity
Solicitation number
36C77624B0012
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document is Attachment 4 - Drawings Vol 1 - Part 2 related to the federal contract opportunity Solicitation Number 36C77624B0012 for the Y1DA--EHRM Infrastructure Upgrades Construction project in San Juan.

The solicitation is for general construction, infrastructure upgrades, and renovations to existing spaces at multiple buildings at the San Juan VA medical campus. The work includes electrical, HVAC, communication, physical security, and fiber infrastructure upgrades campus-wide. The project also involves data center WAN updates and hazardous material abatement. The Department of Veterans Affairs Technology Acquisition Center Austin is the procuring agency. No other specific details regarding response dates, award information, pricing terms, or set asides are provided in this attachment.

View the file

Other files for this federal contract opportunity

Other files attached to Y1DA--EHRM Infrastructure Upgrades Construction San Juan, newest first.
File Type Posted
36C77624B0012 0004.pdf PDF
AE302.pdf PDF
Clarifications to Technical Questions 7-17-24.pdf PDF
014535.pdf PDF
36C77624B0012 0003.pdf PDF
AE500.pdf PDF
Fig 2 Borings Logs Location-Soil Report 2010.pdf PDF
GI103.pdf PDF
Mechanical_Addendum01.pdf PDF
Electrical_Addendum01.pdf PDF
GI300.pdf PDF
Structural_Addendum01.pdf PDF
Technology_Addendum01.pdf PDF
283100 Fire Detection and Alarm.pdf PDF
VASJ iSTAR Controller COMM ROOMS Inventory Jun 28 2024.xls XLS spreadsheet
Technical Questions - FINAL - San Juan - 6-28-24.pdf PDF
01-AE103b.pdf PDF
VACHS San Juan Geotehcnical Engineering Report on Sobsoil Exploration .pdf PDF
VASJ APC COMM ROOM Controller Inventory Jun 28 2024.xls XLS spreadsheet
36C77624B0012 0002.pdf PDF
36C77624B0012 0001.pdf PDF
Site Visit Sign-in Sheet - San Juan 5-14-24.pdf PDF
ATTACHMENT 1 - Specifications Vol 1.pdf PDF
ATTACHMENT 6 - Drawings Vol 1 - Part 4.pdf PDF
ATTACHMENT 7 - Drawings Vol 1 - Part 5.pdf PDF
ATTACHMENT 10 - Drawings Vol 2 - Part 3.pdf PDF
ATTACHMENT 3 - Drawings Vol 1 - Part 1.pdf PDF
ATTACHMENT 9 - Drawings Vol 2 - Part 2.pdf PDF
ATTACHMENT 14 - Brand Name Justification - San Juan.pdf PDF
ATTACHMENT 15 - DOL Prevailing Wage Resource Book.pdf PDF
ATTACHMENT 16 - Limitations on Subcontracting - Construction.docx DOCX document
ATTACHMENT 17 - Site Visit Instructions.pdf PDF
36C77624B0012 - 4-25-24.pdf PDF
ATTACHMENT 2 - Specifications Vol 2.pdf PDF
ATTACHMENT 5 - Drawings Vol 1 - Part 3.pdf PDF
ATTACHMENT 8 - Drawings Vol 2 - Part 1.pdf PDF
ATTACHMENT 12 - CFD Analysis Report.pdf PDF
ATTACHMENT 13 - Pre-Construction Risk Assessment.pdf PDF
ATTACHMENT 11 - Hazmat Report.pdf PDF
Show all 39

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VA Caribbean Health Care System EHRM Life Safety Review:

PROJECT DESCRIPTION:

UPGRADE THE FACILITY INFRASTRUCTURE TO SUPPORT THE NEW ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM) SYSTEM IN ACCORDANCE WITH VA OEHRM SITE INFRASTRUCTURE

REQUIREMENTS (PROVIDED BY VHA). THE PROJECT SHALL INCLUDE, BUT IS NOT LIMITED TO, UPGRADING ALL THE FACILITY IT CLOSETS INFRASTRUCTURE AS NECESSARY IN BUILDINGS 1, 2, 19, 10, 20, 26, 29, 30, 40, 50,51, 52, 53, 54, 60. AS PARTS OF THIS UPGRADE THE IT CLOSETS MOST COMPLY WITH THE NEW OIT SPACE STANDARDS IN ORDER TO INSTALL 3 RACKS PER ROOM, UPGRADE FACILITY POWER DISTRIBUTION AS REQUIRED TO PROVIDE THE NECESSARY ELECTRICAL OUTLETS (EMERGENCY AND NORMAL POWER) TO PROVIDE REDUNDANCY IN ALL ELECTRICAL COMPONENT, IN ADDITION EVERY TELECOMMUNICATION RACKS SHALL HAVE AT LEAST ONE UPS WITH 30 MINUTES MINIMUM OF RUNNING TIME CAPACITY AND REMOTE MONITORING CAPABILITIES, PROVIDE NEW FIBER THROUGHOUT THE BUILDINGS, PROVIDE A REDUNDANT FIBER RUN THROUGHOUT THE FACILITY TO EACH IT CLOSET, PROVIDE REDUNDANT FIBER MAINS TO THE DEMARCATION ROOM FROM THE PROVIDER POINT, UPGRADE FACILITY HVAC DISTRIBUTION AS REQUIRED TO PROVIDE DEDICATE COOLING SYSTEM TO ALL IT CLOSETS, PHYSICAL SECURITY

ASSESSMENT AND UPGRADES AND HAZARDOUS MATERIAL ABATEMENT.

A NEW DATA CENTER ON THE 3RD FLOOR OF BUILDING 1 IS BEING CREATED BY THIS PROJECT TO SERVE AS THE NEW CAMPUS MEDICAL RECORDS DATA CENTER, REQUIRING COMPLIANCE WITH NFPA 75 AND ADDITIONAL VA POLICY REQUIREMENTS - USE OF STANDARD RESPONSE SPRINKLERS WITH FUSIBLE LINKS (RATHER THAN GLASS BULBS) AND MECHANICAL GUARDS ARE REQUIRED. ADDITIONAL REQUIREMENTS

INCLUDE:

• PROVISION OF CLEAN AGENT EXTINGUISHING SYSTEM IN THE DATA CENTER

• DETECTION

• 1-HOUR SEPARATION OF THE DATA CENTER

• PROVISION OF FIRE DAMPERS AND/OR COMBINATION FIRE/SMOKE DAMPERS IN DUCT PENETRATIONS

• PROVISION OF EMERGENCY LIGHTING

• PROVISION OF EMERGENCY POWER OFF SWITCH(ES) FOR ELECTRICAL POWER

• EMERGENCY OFF SWITCHES FOR HVAC; AND PROVISION OF A SEPARATE SPRINKLER ZONE FOR THE

DATA CENTER

LIFE SAFETY ANALYSIS:

THE WORK BEING PERFORMED AT THE VA CARIBBEAN HEALTH CARE SYSTEM IN SAN JUAN PUERTO RICO IS RENOVATION WITH SOME MINOR MODIFICATIONS THAT DO NOT AFFECT EGRESS OR EGRESS CAPACITY.

CHAPTER 19 – EXISTING CONTRUCTION IS THE APPLICABLE CODE SECTION APPLIED TO THE DESIGN REVIEW ALONG WITH CHAPTER 43 – BUILDING REHABILITATION. DATA CENTER CONSTRUCTION WILL BE

COMPLIANT WITH CHAPTER 38 – NEW BUSINESS.

THE IT CLOSETS AND DATA ROOMS ARE NON-OCCUPIED SPACE AND DO NOT ADD TO THE OCCUPANT LOAD.

THE ROOMS INCLUDED IN THIS PROJECT ARE NOT DEEMED HAZARDOUS AND DO NOT REQUIRE CHANGES TO THE FIRE/SMOKE BARRIERS. ADJACENT RATED BARRIERS TO THE IT ROOMS WILL BE REQUIRED TO BE MAINTAINED DURING THE PROJECT WITH COMPLIANT BARRIERS FREE FROM PENETRATIONS AT THE END

OF THE PROJECT.

THE DATA CENTER IS EVALUATED BASED ON OCCUPANCY LOAD AND EGRESS CAPACITY. THE DATA CENTER ROOM(S) ARE TO BE SEPERATED BY A (1) HR BARRIER AND TREATED AS A HAZARDOUS AREA.

CLEAN AGENT FIRE EXTINGUISHERS ARE TO BE LOCATED WITHIN 75 FEET OF EACH DATA ROOM AND

WITHIN THE DATA CENTER.

SPECIAL CARE SHOULD BE TAKEN TO CLEARLY IDENTIFY ALL FIRE/SMOKE BARRIERS THAT WILL BE AFFECTED BY THE REMOVAL/INSTALL OF CABLING. LIFE SAFETY DRAWINGS FOR BUILDINGS 1, 10, 19, 26, AND 30 ARE BEING PROVIDED BY THE VA AS A REFERENCE. ALL RATED BARRIERS THAT ARE PENETRATED

MUST BE REPAIRED WITH AN APPROVED UL FIRESTOP SYSTEM.

7.1.10 MEANS OF EGRESS RELIABILITY.

7.1.10.1* MAINTENANCE. MEANS OF EGRESS SHALL BE CONTINUOUSLY MAINTAINED FREE OF ALL

OBSTRUCTIONS OR IMPEDIMENTS TO FULL INSTANT USE IN THE CASE OF FIRE OR OTHER

EMERGENCY.

8.2.2.2 FIRE COMPARTMENTS SHALL BE FORMED WITH FIRE BARRIERS THAT COMPLY WITH

SECTION 8.3.

8.3 FIRE BARRIERS

8.3.1.1 FIRE BARRIERS USED TO PROVIDE ENCLOSURE, SUBDIVISION, OR PROTECTION UNDER THIS CODE SHALL BE CLASSIFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING FIRE RESISTANCE

RATINGS:

• (1) 3-HOUR FIRE RESISTANCE RATING

• (2) 2-HOUR FIRE RESISTANCE RATING

• (3) 1-HOUR FIRE RESISTANCE RATING

• (4)* 1⁄2-HOUR FIRE RESISTANCE RATING

8.3.1.2 FIRE BARRIERS SHALL COMPLY WITH ONE OF THE FOLLOWING:

• (1) THE FIRE BARRIERS ARE CONTINUOUS FROM OUTSIDE WALL TO OUTSIDE WALL OR FROM

ONE FIRE BARRIER TO ANOTHER, OR A COMBINATION THEREOF, INCLUDING CONTINUITY

THROUGH ALL CONCEALED SPACES, SUCH AS THOSE FOUND ABOVE A CEILING, INCLUDING

INTERSTITIAL SPACES.

• (2) THE FIRE BARRIERS ARE CONTINUOUS FROM OUTSIDE WALL TO OUTSIDE WALL OR FROM

ONE FIRE BARRIER TO ANOTHER, AND FROM THE FLOOR TO THE BOTTOM OF THE INTERSTITIAL

SPACE, PROVIDED THAT THE CONSTRUCTION ASSEMBLY FORMING THE BOTTOM OF THE

INTERSTITIAL SPACE HAS A FIRE RESISTANCE RATING NOT LESS THAN THAT OF THE FIRE

BARRIER.

9.2.1 AIR-CONDITIONING, HEATING, VENTILATING DUCTWORK, AND RELATED EQUIPMENT.

AIR-CONDITIONING, HEATING, VENTILATING DUCTWORK, AND RELATED EQUIPMENT SHALL BE IN ACCORDANCE WITH NFPA 90A OR NFPA 90B, AS APPLICABLE, UNLESS SUCH INSTALLATIONS ARE APPROVED EXISTING INSTALLATIONS, WHICH SHALL BE PERMITTED TO BE CONTINUED IN SERVICE.

19.1.1.4.3 REHABILITATION.

19.1.1.4.3.1 FOR PURPOSES OF THE PROVISIONS OF THIS CHAPTER, THE

FOLLOWING SHALL APPLY:

(2) A MINOR REHABILITATION SHALL INVOLVE THE MODIFICATION OF NOT MORE THAN 50 PERCENT, AND NOT MORE THAN 4500 FT2 (420 M2), OF THE AREA OF THE SMOKE COMPARTMENT.

19.1.1.4.3.2 WORK THAT IS EXCLUSIVELY PLUMBING, MECHANICAL, FIRE PROTECTION SYSTEM, ELECTRICAL, MEDICAL GAS, OR MEDICAL EQUIPMENT WORK SHALL NOT BE INCLUDED IN THE

COMPUTATION OF THE MODIFICATION AREA WITHIN THE SMOKE COMPARTMENT

19.2.2.2.4 DOORS WITHIN A REQUIRED MEANS OF EGRESS SHALL NOT BE EQUIPPED WITH A LATCH OR LOCK THAT REQUIRES THE USE OF A TOOL OR KEY FROM THE EGRESS SIDE, UNLESS OTHERWISE

PERMITTED BY ONE

OF THE FOLLOWING:

(1) LOCKS COMPLYING WITH 19.2.2.2.5 SHALL BE PERMITTED.

19.2.2.2.5.1* DOOR-LOCKING ARRANGEMENTS SHALL BE PERMITTED WHERE THE CLINICAL NEEDS OF

PATIENTS REQUIRE SPECIALIZED SECURITY MEASURES OR WHERE PATIENTS POSE A SECURITY

THREAT, PROVIDED THAT STAFF CAN READILY UNLOCK DOORS AT ALL TIMES IN ACCORDANCE WITH 19.2.2.2.6.

VA Caribbean Health Care System EHRM Life Safety Review (cont):

19.3 PROTECTION.

19.3.4.1 GENERAL. HEALTH CARE OCCUPANCIES SHALL BE PROVIDED WITH A FIRE ALARM SYSTEM IN

ACCORDANCE WITH SECTION 9.6.

19.3.5.1 BUILDINGS CONTAINING HEALTH CARE OCCUPANCIES SHALL BE PROTECTED THROUGHOUT BY AN APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 9.7, UNLESS OTHERWISE PERMITTED BY 19.3.5.5.

19.3.5.12 PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN ALL HEALTH CARE OCCUPANCIES

IN ACCORDANCE WITH SECTION 9.9.

19.3.6 CORRIDORS.

19.3.6.1 CORRIDOR SEPARATION. CORRIDORS SHALL BE SEPARATED FROM ALL OTHER AREAS BY PARTITIONS COMPLYING WITH 19.3.6.2 THROUGH 19.3.6.5 (SEE ALSO 19.2.5.4), UNLESS OTHERWISE

PERMITTED BY ONE OF THE FOLLOWING:

19.3.6.2 CONSTRUCTION OF CORRIDOR WALLS.

19.3.6.2.1 CORRIDOR WALLS SHALL BE PERMITTED TO TERMINATE AT THE CEILING WHERE THE

CEILING IS CONSTRUCTED TO LIMIT THE TRANSFER OF SMOKE.

19.3.6.2.2 NO FIRE RESISTANCE RATING SHALL BE REQUIRED FOR CORRIDOR WALLS.

19.3.6.2.3 CORRIDOR WALLS SHALL FORM A BARRIER TO LIMIT THE TRANSFER OF SMOKE.

19.3.6.3 CORRIDOR DOORS.

19.3.6.3.1 DOORS, INCLUDING DOORS OR PANELS TO NURSE SERVERS AND PASS-THROUGH

OPENINGS, PROTECTING CORRIDOR OPENINGS SHALL BE CONSTRUCTED TO RESIST THE PASSAGE

OF SMOKE, AND THE FOLLOWING ALSO SHALL APPLY:

(1) COMPLIANCE WITH NFPA 80 SHALL NOT BE REQUIRED.

(3) FOR DOORS PROTECTING PASS-THROUGH OPENINGS, A CLEARANCE BETWEEN THE BOTTOM OF

THE DOOR AND THE SILL NOT EXCEEDING 1⁄8 IN. (3 MM) SHALL BE PERMITTED.

19.3.6.3.11 DOOR-CLOSING DEVICES SHALL NOT BE REQUIRED ON DOORS IN CORRIDOR WALL

OPENINGS OTHER THAN THOSE SERVING REQUIRED EXITS, SMOKE BARRIERS, OR ENCLOSURES OF

VERTICAL OPENINGS AND HAZARDOUS AREAS.

CHAPTER 43 BUILDING REHABILITATION

43.1.3 MULTIPLE REHABILITATION WORK CATEGORIES

43.1.3.1 WORK OF MORE THAN ONE REHABILITATION WORK CATEGORY SHALL BE PERMITTED TO BE

PART OF A SINGLE WORK PROJECT.

43.1.3.2 WHERE A PROJECT INCLUDES ONE CATEGORY OF REHABILITATION WORK IN ONE BUILDING AREA AND ANOTHER CATEGORY OF REHABILITATION WORK IN A SEPARATE AREA OF THE BUILDING, EACH PROJECT AREA SHALL COMPLY WITH THE REQUIREMENTS OF THE RESPECTIVE CATEGORY OF

REHABILITATION WORK.

43.1.3.3 WHERE A PROJECT CONSISTING OF MODIFICATION AND RECONSTRUCTION IS PERFORMED IN THE SAME WORK AREA, OR IN CONTIGUOUS WORK AREAS, THE PROJECT SHALL COMPLY WITH THE REQUIREMENTS APPLICABLE TO RECONSTRUCTION, UNLESS OTHERWISE SPECIFIED IN 43.1.3.4.

43.1.3.4 WHERE THE RECONSTRUCTION WORK AREA IS LESS THAN 10 PERCENT OF THE

MODIFICATION WORK AREA, THE TWO SHALL BE CONSIDERED INDEPENDENT WORK AREAS, AND THE

RESPECTIVE REQUIREMENTS SHALL APPLY.

43.1.4COMPLIANCE

43.1.4.1 REPAIRS, RENOVATIONS, MODIFICATIONS, RECONSTRUCTION, CHANGES OF USE OR

OCCUPANCY CLASSIFICATION, AND ADDITIONS SHALL CONFORM TO THE SPECIFIC REQUIREMENTS

FOR EACH CATEGORY IN OTHER SECTIONS OF THIS CHAPTER.

43.2 REPAIRS

43.2.1 GENERAL REQUIREMENTS

43.3.1.1 A REPAIR, AS DEFINED IN 43.2.2.1.1, IN OTHER THAN HISTORIC BUILDINGS SHALL COMPLY

WITH THE REQUIREMENTS OF SECTION 43.3.

43.3.1.3 THE WORK SHALL BE DONE USING LIKE MATERIALS OR MATERIALS PERMITTED BY OTHER

SECTIONS OF THIS CODE.

43.3.1.4 THE WORK SHALL NOT MAKE THE BUILDING LESS CONFORMING WITH THE OTHER SECTIONS OF THIS CODE, OR WITH ANY PREVIOUSLY APPROVED ALTERNATIVE ARRANGEMENTS, THAN IT WAS

BEFORE THE REPAIR WAS UNDERTAKEN.

43.4 RENOVATIONS

43.4.1.3 ALL NEW WORK SHALL COMPLY WITH THE REQUIREMENTS OF THIS CODE APPLICABLE TO

EXISTING BUILDINGS.

43.4.1.4 THE WORK SHALL NOT MAKE THE BUILDING LESS CONFORMING WITH OTHER SECTIONS OF

THIS CODE, OR WITH ANY PREVIOUSLY APPROVED ALTERNATIVE ARRANGEMENTS, THAN IT WAS

BEFORE THE RENOVATION WAS UNDERTAKEN, UNLESS OTHERWISE SPECIFIED IN 43.4.1.5.

43.4.1.5 MINOR REDUCTIONS IN THE CLEAR OPENING DIMENSIONS OF REPLACEMENT DOORS AND WINDOWS THAT RESULT FROM THE USE OF DIFFERENT MATERIALS SHALL BE PERMITTED UNLESS

SUCH REDUCTIONS ARE PROHIBITED.

43.4.2 CAPACITY OF MEANS OF EGRESS THE CAPACITY OF MEANS OF EGRESS, DETERMINED IN

ACCORDANCE WITH SECTION 7.3, SHALL BE SUFFICIENT FOR THE OCCUPANT LOAD THEREOF,

UNLESS ONE OF THE FOLLOWING CONDITIONS EXISTS:

(2) *THE EGRESS CAPACITY SHALL HAVE BEEN PREVIOUSLY APPROVED AS BEING ADEQUATE.

43.4.3 INTERIOR FINISH REQUIREMENTS NEW INTERIOR FINISH MATERIALS SHALL MEET THE

REQUIREMENTS FOR NEW CONSTRUCTION.

43.4.4 OTHER REQUIREMENTS THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE

INSTALLATION OF ANY ADDITIONAL EQUIPMENT, SHALL COMPLY WITH SECTION 43.5.

43.5 MODIFICATIONS

43.5.1GENERALREQUIREMENTS

43.5.1.1 A MODIFICATION, AS DEFINED IN 43.2.2.1.3, IN OTHER THAN HISTORIC BUILDINGS SHALL

COMPLY WITH BOTH OF THE FOLLOWING:

(1) SECTION 43.5

(2) SECTION 43.4

43.5.1.3 NEWLY CONSTRUCTED ELEMENTS, COMPONENTS, AND SYSTEMS SHALL COMPLY WITH THE

REQUIREMENTS OF OTHER SECTIONS OF THIS CODE APPLICABLE TO NEW CONSTRUCTION.

VA Caribbean Health Care System EHRM Life Safety Review (cont):

NFPA 241, 2019 - SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS

8.6.2.1 PROTECTION SHALL BE PROVIDED TO SEPARATE AN OCCUPIED PORTION OF THE STRUCTURE FROM A PORTION OF THE STRUCTURE UNDERGOING ALTERATION, CONSTRUCTION, OR DEMOLITION OPERATIONS WHEN SUCH OPERATIONS ARE CONSIDERED AS HAVING A HIGHER LEVEL OF HAZARD

THAN THE OCCUPIED PORTION OF THE BUILDING.

8.6.2.1.1 WALLS SHALL HAVE AT LEAST A 1-HOUR FIRE RESISTANCE RATING.

8.6.2.1.2 OPENING PROTECTIVES SHALL HAVE AT LEAST A 45-MINUTE FIRE PROTECTION RATING.

8.6.2.2 WALLS IN 8.6.2.1.1 AND OPENING PROTECTIVES IN 8.6.2.1.2 SHALL BE PERMITTED TO BE NONRATED WHEN AN APPROVED AUTOMATIC SPRINKLER SYSTEM IS INSTALLED AND OPERATIONAL.

TR ROOMS AND THE DATA CENTER IS CONSIDERED TO BE UNOCCUPIED SPACE; A BUILDING SERVICE EQUIPMENT SUPPORT AREA IN WHICH PEOPLE ARE NOT EXPECTED TO BE PRESENT ON A REGULAR BASIS.

**IF FLOOR OR RATED WALL PENETRATIONS CANNOT BE FIRESTOPPED AT THE END OF THE

WORK SHIFT DUE TO THE NEED TO PULL ADDITIONAL CABLES, TEMPORARY FIRESTOPPING COMPOSED OF MINERAL WOOL SHOULD BE INSTALLED IN THE PENETRATION TO PROVIDE PROTECTION AGAINST

FIRE/SMOKE SPREAD THROUGH THE UNSEALED PENETRATION. **

**ALL RATED BARRIER PENETRATIONS ARE TO BE REPAIRED WITH AN APPROVED UL SYSTEM**

** CONSTRUCTION AREAS MUST BE SEPARATED FROM THE SURROUNDING OCCUPIED AREAS UNLESS THE

WORK IS NO MORE HAZARDOUS THAN NORMAL OPERATIONS. PULLING CABLING WOULD NOT BE

CONSIDERED HAZARDOUS BUT THE DEMOLITION ASSOCIATED WITH CREATING OR EXPANDING TRS NAY BE. THIS MUST BE APPROVED BY THE AHJ (VISN SAFETY ENGINEER) IF THIS IS THE DESIGN BASIS. **

**EVEN IF THE WORK IS HAZARDOUS, IT IS ACCEPTABLE TO USE NON-RATED BARRIERS (PLASTIC SHEETING) FOR CONSTRUCTION AREA SEPARATION IF THE SPRINKLERS WITHIN THE CONSTRUCTION AREA BEING OPERABLE. REMOVAL OF MORE THAN ONE CEILING TILE WITHIN THE PROTECTION AREA OF A SPRINKLER CAN RENDER THE SPRINKLER INEFFECTIVE DUE TO HEAT ENTERING THE CEILING PLENUM AND

BYPASSING THE SPRINKLER. **

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

421 King ST Suite 301 Alexandria, VA 22314 703-772-4213

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

LIFE SAFETY REVIEW

LS100

2-

-7

. L

S1

. 1 0/

/2

0.

pd f

M L

EXIST.

C

H

ASE

JANITOR

3107.1

UTLITIES SHAFT

#2

EXISTING

SERVICE

ELVATOR

EXISTING

SERVICE

ELEVATOR

EXISTING STAIR

#2

EXISTING

CHASE

EXISTING

ELECTRICAL

CLOSET

3000.4

SHELL SPACE

FUTURE

COMPUTER

ROOM

J-1C

TR

BLACK

OUT

FILM

BLACK

OUT

FILM

BLACK

OUT

FILM

BLACK

OUT

FILM

BLACK OUT

FILM

BLACK OUT

FILM

BLACK OUT

FILM

BLACK OUT

FILM

NEW SIGN

NEW SIGN

NEW SIGN

PATH TO EXIT 73'-3"

REQUIRED TRAVEL DISTANCE:

UNDER 200'-0"

FEC

FIRE

PROTECTION

ROOM

3100.4b

STORAGE

ROOM

3100.4a

CODE ANALYSIS LEGEND

1 HOUR FIRE BARRIER PER NFPA 101 8.6 /

19.3.2.1.2. OPENINGS FIRE RATED FOR 45

MINUTES UNLESS SHAFT, EXIT ENCLOSURE, OR

EXIT PASSAGEWAY WALLS WHICH REQUIRE 1

HOUR RATED OPENINGS.

2 HOUR FIRE BARRIER PER NFPA 101 8.2.

OPENINGS FIRE RATED FOR 90 MINUTES.

EGRESS PATH WITH NAME, SEGMENT LENGTH,

AND DIRECTION INDICATEDPATH A

OPENING RATING IN MINUTES

OPENING RATING IN MINUTES

FEC FIRE EXTINGUISHER CABINET

EXIT SIGN

SMOKE BARRIER PER NFPA 101 19.3.7.3.

OPENINGS FIRE RATED FOR 20 MIN.20

OPENING RATING IN MINUTES

NEW DATA CENTER

EXIT 2A

EXIT 2

EXIT 1

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

421 King ST Suite 301 Alexandria, VA 22314 703-772-4213

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

BUILDING 1 - MAIN BUILDING - THIRD

FLOOR LIFE SAFETY PLAN

01-LS103

2-

-7

. 0

1-

LS

3.

1/

/2

3.

pd f

1/4" = 1'-0"1 BUILDING 1 - MAIN BUILDING - THIRD FLOOR LIFE SAFETY PLAN

N

SITE KEY PLAN

TRUE NORTH

1/16" = 1'-0"2 BUILDING 1 - MAIN BUILDING - EXISTING THIRD FLOOR

UNOCCUPIED SPACE

1D168b

1D168

1D164

1D168c

1D168a

1D161b

1D161 1D161a C1-1B

DISHWASHING

W. TOIL

LOBBY

TERAPY

PHYSICAL

DIETETIC

STO.

ROOM

TERAPIST

HYD

O.T. CLINIC

N.H.C.U.

STO.

STO.

SECRETARY

AND WAITING

AREA

C M

E

LE

C

R O O M

C O M

R O O M

H O U S E

K E E P

IN

G

PAT . R

O

O M

# 1

PAT . R

O

O M

# 2

PAT . R

O

O M

# 3

PAT . R

O O

M # 15

PAT . R

O

O M

# 16

PAT . R

O

O M

# 17

S

TA

F F

TO

I.

M A L E

S

TA

F F

TO

I.

F E M

B

IO

M E D

W A S T

1H-1 00

1H-1 00a

1H-1 01

1H-1 02

1H-1 01a

1H-1 22

1H-1 23

1H-1 24

1H-1 35 1H-1 36

1H-1 37

1H-1 38 1H-1 39

1H-1 39a

1H-1 25 1H-1 34

1H-1 26

1H-1 27 1H-1 32

1H-1 33

CO

R RIDO

R C -___

S U R G

IC

A L

S

TO

R A G E

D G S F

P

2A104

2A123

2B125

2B126 2A109

2A108

2A106

2A112

2A110

2A124

2A111

2A113

2A114

2A122

2A121

2A115

2A116

2A117

2A120

2A119

2A118

2A107 2A105

C

TERRACE

CARE

HOME

STAFF

COMMON

CLEAN

BATHROOM

BATH

LINEN

HEAD

NURSE

KITCHEN

H.K.PHARMACY

NURSE

KITCHEN

NURSE

BATHROOM

ELEC.

BEDROOM

TWO BED

TWO BED

BEDROOM

BEDROOM

TWO BED

BEDROOM

TWO BED

TWO BED

BEDROOM

BEDROOM

TWO BED

TWO BED

BEDROOM

ONE BED

BEDROOM

ONE BED

BEDROOM

BEDROOM

ONE BED

# 1

BEDROOM

ONE BED

H.A.C.

TOIL.

STAIR

CODE ANALYSIS LEGEND

1 HOUR FIRE BARRIER PER NFPA 101 8.6 /

19.3.2.1.2. OPENINGS FIRE RATED FOR 45

MINUTES UNLESS SHAFT, EXIT ENCLOSURE, OR

EXIT PASSAGEWAY WALLS WHICH REQUIRE 1

HOUR RATED OPENINGS.

2 HOUR FIRE BARRIER PER NFPA 101 8.2.

OPENINGS FIRE RATED FOR 90 MINUTES.

EGRESS PATH WITH NAME, SEGMENT LENGTH,

AND DIRECTION INDICATEDPATH A

OPENING RATING IN MINUTES

OPENING RATING IN MINUTES

FEC FIRE EXTINGUISHER CABINET

EXIT SIGN

SMOKE BARRIER PER NFPA 101 19.3.7.3.

OPENINGS FIRE RATED FOR 20 MIN.20

OPENING RATING IN MINUTES

TR

1C1-1B

SMOKE COMPARTMENT

SC1-1 = 22,171SF

OCCUPANT PER SF = 240

MAX OCCUPANT LOAD = 93

PATH TO EXIT 30'-5"

REQUIRED DISTANCE:

UNDER 200'-0"

VESTIBULE

1C1-1A

ELECTRIC

ROOM

1A102

UNOCCUPIED

SPACE

TR

1H-140

PA

TH

T O

E

XI

T

'-2

R

EQ

U

IR

ED

D

IS

TA

N C

E:

U N

D

ER

'-0

UNOCCUPIED

SPACE

SMOKE COMPARTMENT

SC1-1 = 8,906SF

OCCUPANT PER SF = 120

MAX OCCUPANT LOAD = 75

TR

2A104b

OFFICE

2A104a

HOME CARE

2A104

ELECTRIC

ROOM

2A102

PATH TO EXIT 196'-2"

REQUIRED DISTANCE:

UNDER 200'-0"

UNOCCUPIED

SPACE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

950 N.

WASHINGTON ST

SUITE 334

ALEXANDRIA, VA

22314

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

BUILDING 10 AND 26 LIFE SAFETY

PLANS

10-LS100

2-

-7

. 1

0-

LS

0.

1/

/2

3.

pd f

N

SITE KEY PLAN

TRUE NORTH

1/8" = 1'-0"2 BUILDING 10 - NURSING HOME CLC - FIRST FLOOR LIFE SAFETY PLAN

1/8" = 1'-0"1 BUILDING 26 - FIRST FLOOR LIFE SAFETY PLAN

1/8" = 1'-0"3 BUILDING 10 - NURSING HOME CLC - SECOND FLOOR LIFE SAFETY PLAN

FEC

FEC

FEC

UP

DN

PHPSYCH.

CONF./CLASS

PHARMACY

H.NURSES

PSYCHOLOGIST

Y

OVE

BATH

ANTERM.

M T

TATION

DAY RM.

RECREATION, DINING

SOIL. UT. NURS.

SUPERV.

TEL.

STAFF

TOIL. STORAGE

VISIT. WAIT

FIM. V

TOILE

1-BED IS. (1)

SECLUSION

VESTIBULE

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

RECYC.

2-BED (6) 2-BED (7)

BATHBATH

J-2210

J-2208

K-2209

K-2268B

K-2287A

K-2287B

J-2

K-2298

K-2292 K 2295

K-2289

K-2297 K-2298A

J-2253

J-2253

K-2287

J-2253A

C2-3

C2-14

C3-11

C2-2

J-C29A

K-2288 K-2290

K-2290AK-2288A

S2-3 x;Sx;S

FEC

FEC

STAIR

S1-3

CASE

MNGR OFF

CLINIC

NURSES SPEC. H.NURSE

SOIL.UT.

K-1198

ART.

28 NURSES

STA.

M. TLT.

J-1113

F.TLT.

J-1115

DIETARY

CART ALCOVE

C1-12B

CORRIDOR

C1-12A

CORRIDOR

CORRIDOR

C1-3

PASSAGE

C1-15

ELECT.

K-1224BOWEL CARE/

SH. EQ.STOR.

K-1223

PHYSICIAN

K-1229

ISOLATION

ROOM (2)

K-1219

ANTERM.(2)

K-1219B

TEL.

K-1226

KITCH.

K-1225B

DINING

K-1225

DAYROOM

K-1225A

SCI DIET.

K-1111

SCI PHARM.

K-1110

SCI SEC'Y.

K-1109

SCI

ADMIN.

K-1107

SCI CHIEF

OFF.

K-1108

STAFF MEET

& CONF.

J-1106

M. STAFF

LOCKERS

J-1112

(MICU)

VISIT. WAIT.

J-1116

CORRIDOR

C1-2

UP

DN

ALCOVE

CRASH CART

x;Sx;S

DINING

PSYCH.

CON

DIETITIAN

PHARMACY

QUIET RM.

SOC. WORK.

NOURISH.

H.NURSES

PHYSICIAN

CONSUL.

M.PREP.

DIETARY

CART ALCOVE

NURSES

STATION

F.VISIT.

TOIL.

1-BED (4) 1-BED (5)

H BATH BATH

EQUIP STOR

1-BED IS. (1)

ANTERM.

TEL.

CORRIDOR

CORRIDOR

CO

CO

CORRIDOR

J-3312

J-3310

K-3398B

K-3309

K-3398A

K-3398

K-3397 K-3398D

K-3398C

K-3359B

C3-15B

K-3356

K-3392 K-3394

2A K-3394A K-3396A

K-3396

K-3396B

K-3395

C3-15

C3-2C3-16

S3-3

STAIR

x;Sx;S

VISIT.W

SOC. WORK.

CONF./CLA

DIETITIAN

PHARMACY

QUIET RM.

SOC. WORK.

H.NURSES

PHYSICIAN

CONSUL. CORRIDOR

CORRID

CORRID

CORRIDOR

NOURISH.

M.PREP.

DIETARY

CART ALCOVE

NURS.

STATION

(3) 1-BED IS.(4)

BATH BATH

M. ANTERM.

TEL.

F.VISIT.

TOIL.

J-44

J-4410

J-440

K-44100

K-4409

K-4499

K-4498

K-44102

K-44101 C4-2

C4-3

C4-10

C4-16

K-4494

K-4459B

C4-15C

K-4493

K-4491A K-4493A

B K-4493B

K-4492

K-4456

STAIR

S4-3 x;Sx;S

C

PHYSIC

J-55

STAIR

S5-3

CORRIDOR

C5-16

CORRIDOR

C5-2

TEL.

K-5592

ANTERM.

K-5593B

BATH

K-5593A

BATH

K-5591A

1-BED IS.(4)

K-5593

F.VISIT.

TOIL.

K-5556NURS.

STATION

DIETARY

CART ALCOVE

C5-15C

M.PREP.

K-5559B

PHYSICIAN

CONSUL.

K-5598

H.NURSES

K-5599

NOURISH.

K-5594

SOC. WORK.

K-5595

DAYRM. RECR.

K-5596

PHARMACY

K-5509

DIETITIAN

K-5597 x;Sx;S

FEC

FEC

CORRIDOR

C6-16 CORRIDOR

C6-2

TEL.

K-6692

ANTERM.

K-6693B

M.

B

BATH

K-6693A

BATH

K-6691A

1-BED IS.(4)

K-6693

S.(3)

F.VISIT.

TOIL.

NURS

DIETARY

CART ALCOVE

C6-15C

M.PREP.

K-6659B

PHYSICIAN

CONSUL.

K-6698

H.NURSES

K-6699NOURISH.

K-6694

SOC. WORK.

K-6695

DAYRM. RECR.

K-6696

PHARMACY

K-6609

DIETITIAN

K-6697

PHYSICIAN

J-6610

STAIR

S6-3

48x48 Tackboard

4 T

FUT

S3x;Sx;S

CORR

CODE ANALYSIS LEGEND

1 HOUR FIRE BARRIER PER NFPA 101 8.6 /

19.3.2.1.2. OPENINGS FIRE RATED FOR 45

MINUTES UNLESS SHAFT, EXIT ENCLOSURE, OR

EXIT PASSAGEWAY WALLS WHICH REQUIRE 1

HOUR RATED OPENINGS.

2 HOUR FIRE BARRIER PER NFPA 101 8.2.

OPENINGS FIRE RATED FOR 90 MINUTES.

EGRESS PATH WITH NAME, SEGMENT LENGTH,

AND DIRECTION INDICATEDPATH A

OPENING RATING IN MINUTES

OPENING RATING IN MINUTES

FEC FIRE EXTINGUISHER CABINET

EXIT SIGN

SMOKE BARRIER PER NFPA 101 19.3.7.3.

OPENINGS FIRE RATED FOR 20 MIN.20

OPENING RATING IN MINUTES

PA

TH

T O

E

XI

T

9' -7

R

EQ

U

IR

ED

D

IS

TA

N

D

ER

'-0

TR

K-2298A

SMOKE COMPARTMENT

SC2-2 = 13,182SF

OCCUPANT PER SF = 120

MAX OCCUPANT LOAD = 110

TR

K-1225C

SMOKE COMPARTMENT

SC1-2 = 17,663SF

OCCUPANT PER SF = 120

MAX OCCUPANT LOAD = 148

PATH TO EXIT 28'-10"

REQUIRED DISTANCE:

UNDER 200'-0"

TR

K-3398B

PA

TH

T O

E

XI

T

3' -1

1" R

EQ

U

IR

ED

D

IS

TA

N

D

ER

'-0

SMOKE COMPARTMENT

SC3-2 = 13,453SF

OCCUPANT PER SF = 120

MAX OCCUPANT LOAD = 113

TR

K-3399A

PA

TH

T O

E

XI

T

3' -1

1" R

EQ

U

IR

ED

D

IS

TA

N

D

ER

'-0

SMOKE COMPARTMENT

SC4-2 = 16,709SF

OCCUPANT PER SF = 120

MAX OCCUPANT LOAD = 140

TR

K-5596A

PA

TH

T O

E

XI

T

3' -1

1" R

EQ

U

IR

ED

D

IS

TA

N

D

ER

'-0

SMOKE COMPARTMENT

SC5-2 = 16,710SF

OCCUPANT PER SF = 120

MAX OCCUPANT LOAD = 140

TR

K-6696A

PA

TH

T O

E

XI

T

3' -1

1" R

EQ

U

IR

ED

D

IS

TA

N

D

ER

'-0

SMOKE COMPARTMENT

SC6-2 = 16,716SF

OCCUPANT PER SF = 120

MAX OCCUPANT LOAD = 140

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

950 N.

WASHINGTON ST

SUITE 334

ALEXANDRIA, VA

22314

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

BUILDING 30 - SOUTH BED TOWER -

LIFE SAFETY PLANS

30-LS100

2-

-7

. 3

0-

LS

0.

1/

/2

3.

pd f

N

SITE KEY PLAN

TRUE NORTH

1/8" = 1'-0"2 BUILDING 30 - SOUTH BED TOWER - SECOND FLOOR LIFE SAFETY PLAN

1/8" = 1'-0"1 BUILDING 30 - SOUTH BED TOWER - FIRST FLOOR LIFE SAFETY PLAN

1/8" = 1'-0"3

BUILDING 30 - SOUTH BED TOWER

THIRD FLOOR LIFE SAFETY PLAN

1/8" = 1'-0"4 BUILDING 30 - SOUTH BED TOWER - FOURTH FLOOR LIFE SAFETY PLAN

1/8" = 1'-0"5 BUILDING 30 - SOUTH BED TOWER - FIFTH FLOOR LIFE SAFETY PLAN

1/8" = 1'-0"6 BUILDING 30 - SOUTH BED TOWER - SIXTH FLOOR LIFE SAFETY PLAN

UNOCCUPIED

SPACE

UNOCCUPIED

SPACE UNOCCUPIED

SPACE

UNOCCUPIED

SPACE UNOCCUPIED

SPACE

UNOCCUPIED

SPACE

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

950 N.

WASHINGTON ST

SUITE 334

ALEXANDRIA, VA

22314

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

CAMPUS REFERENCE

LS.01-REF

2-

-7

. L

S.

-R

EF

. 0 1/

/2

3.

pd

FOR REFERENCE ONLY

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

421 King ST Suite 301 Alexandria, VA 22314 703-772-4213

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

LEVEL ONE LIFE SAFETY PLAN

REFERENCE

LS.1.1.1-REF

2-

-7

. L

S.

1.

1.

1-

R

EF

. 0 1/

/2

3.

pd f

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

950 N.

WASHINGTON ST

SUITE 334

ALEXANDRIA, VA

22314

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

LEVEL ONE LIFE SAFETY PLAN

REFERENCE

LS.1.1.2-REF

2-

-7

. L

S.

1.

1.

2-

R

EF

. 0 1/

/2

3.

pd f

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

950 N.

WASHINGTON ST

SUITE 334

ALEXANDRIA, VA

22314

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

LEVEL TWO LIFE SAFETY PLAN

REFERENCE

LS.1.2.1-REF

2-

-7

. L

S.

1.

2.

1-

R

EF

. 0 1/

/2

3.

pd f

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

950 N.

WASHINGTON ST

SUITE 334

ALEXANDRIA, VA

22314

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

LEVEL TWO LIFE SAFETY PLAN

REFERENCE

LS.1.2.2-REF

2-

-7

. L

S.

1.

2.

2-

R

EF

. 0 1/

/2

3.

pd f

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

950 N.

WASHINGTON ST

SUITE 334

ALEXANDRIA, VA

22314

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

BASEMENT LEVEL LIFE SAFETY PLAN

REFERENCE

LS.1.B.1-REF

2-

-7

. L

S.

1.

B.

1-

R

EF

. 0 1/

/2

3.

pd f

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

950 N.

WASHINGTON ST

SUITE 334

ALEXANDRIA, VA

22314

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

BASEMENT LEVEL LIFE SAFETY PLAN

REFERENCE

LS.1.B.2-REF

2-

-7

. L

S.

1.

B.

2-

R

EF

. 0 1/

/2

3.

pd f

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

950 N.

WASHINGTON ST

SUITE 334

ALEXANDRIA, VA

22314

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

LIFE SAFETY ASSESSMENT

PARTITION LEGENDS & APPLICABLE

CODES REFERENCE

LS.02-REF

2-

-7

. L

S.

-R

EF

. 0 1/

/2

3.

pd

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

950 N.

WASHINGTON ST

SUITE 334

ALEXANDRIA, VA

22314

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

COMPARTMENT CALCULATIONS,

SUITES, BLDG. SQUARE FOOTAGE

REFERENCE

LS.03-REF

2-

-7

. L

S.

-R

EF

. 0 1/

/2

3.

pd

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

421 King ST Suite 301 Alexandria, VA 22314 703-772-4213

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

LEVEL ONE LIFE SAFETY PLAN

REFERENCE

LS.10.1-REF

2-

-7

. L

S.

.1 -R

EF

. 0

1/

/2 3.

pd f

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:

Revisions: Date:

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

CONSULTANT:

Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122

ARCHITECT:

CB DESIGN GROUP

950 N.

WASHINGTON ST

SUITE 334

ALEXANDRIA, VA

22314

PROFESSIONAL SEAL:

VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

CONSULTANT:

Integrity Federal Services 148 S. Queen Street Suite 201

CONSULTANT:

IMEG

15 Sunnen Drive Suite St. Louis, MO 63143

12 / 11 / 2023

672-21-700

AuthorChecker

EHRM INFRASTRUCTURE UPGRADE

SAN JUAN PR

BID DOCUMENTS SUBMISSION

LEVEL TWO LIFE SAFETY PLAN

REFERENCE

LS.10.2-REF

2-

-7

. L

S.

.2 -R

EF

. 0

1/

/2 3.

pd f