ATTACHMENT 4 - Drawings Vol 1 - Part 2.pdf
PDF 44 MB Posted
- Attached to
- Y1DA--EHRM Infrastructure Upgrades Construction San Juan Federal contract opportunity
- Solicitation number
- 36C77624B0012
About this file
This document is Attachment 4 - Drawings Vol 1 - Part 2 related to the federal contract opportunity Solicitation Number 36C77624B0012 for the Y1DA--EHRM Infrastructure Upgrades Construction project in San Juan.
The solicitation is for general construction, infrastructure upgrades, and renovations to existing spaces at multiple buildings at the San Juan VA medical campus. The work includes electrical, HVAC, communication, physical security, and fiber infrastructure upgrades campus-wide. The project also involves data center WAN updates and hazardous material abatement. The Department of Veterans Affairs Technology Acquisition Center Austin is the procuring agency. No other specific details regarding response dates, award information, pricing terms, or set asides are provided in this attachment.
View the file
Other files for this federal contract opportunity
Show all 39
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VA Caribbean Health Care System EHRM Life Safety Review:
PROJECT DESCRIPTION:
UPGRADE THE FACILITY INFRASTRUCTURE TO SUPPORT THE NEW ELECTRONIC HEALTH RECORD
MODERNIZATION (EHRM) SYSTEM IN ACCORDANCE WITH VA OEHRM SITE INFRASTRUCTURE
REQUIREMENTS (PROVIDED BY VHA). THE PROJECT SHALL INCLUDE, BUT IS NOT LIMITED TO, UPGRADING ALL THE FACILITY IT CLOSETS INFRASTRUCTURE AS NECESSARY IN BUILDINGS 1, 2, 19, 10, 20, 26, 29, 30, 40, 50,51, 52, 53, 54, 60. AS PARTS OF THIS UPGRADE THE IT CLOSETS MOST COMPLY WITH THE NEW OIT SPACE STANDARDS IN ORDER TO INSTALL 3 RACKS PER ROOM, UPGRADE FACILITY POWER DISTRIBUTION AS REQUIRED TO PROVIDE THE NECESSARY ELECTRICAL OUTLETS (EMERGENCY AND NORMAL POWER) TO PROVIDE REDUNDANCY IN ALL ELECTRICAL COMPONENT, IN ADDITION EVERY TELECOMMUNICATION RACKS SHALL HAVE AT LEAST ONE UPS WITH 30 MINUTES MINIMUM OF RUNNING TIME CAPACITY AND REMOTE MONITORING CAPABILITIES, PROVIDE NEW FIBER THROUGHOUT THE BUILDINGS, PROVIDE A REDUNDANT FIBER RUN THROUGHOUT THE FACILITY TO EACH IT CLOSET, PROVIDE REDUNDANT FIBER MAINS TO THE DEMARCATION ROOM FROM THE PROVIDER POINT, UPGRADE FACILITY HVAC DISTRIBUTION AS REQUIRED TO PROVIDE DEDICATE COOLING SYSTEM TO ALL IT CLOSETS, PHYSICAL SECURITY
ASSESSMENT AND UPGRADES AND HAZARDOUS MATERIAL ABATEMENT.
A NEW DATA CENTER ON THE 3RD FLOOR OF BUILDING 1 IS BEING CREATED BY THIS PROJECT TO SERVE AS THE NEW CAMPUS MEDICAL RECORDS DATA CENTER, REQUIRING COMPLIANCE WITH NFPA 75 AND ADDITIONAL VA POLICY REQUIREMENTS - USE OF STANDARD RESPONSE SPRINKLERS WITH FUSIBLE LINKS (RATHER THAN GLASS BULBS) AND MECHANICAL GUARDS ARE REQUIRED. ADDITIONAL REQUIREMENTS
INCLUDE:
• PROVISION OF CLEAN AGENT EXTINGUISHING SYSTEM IN THE DATA CENTER
• DETECTION
• 1-HOUR SEPARATION OF THE DATA CENTER
• PROVISION OF FIRE DAMPERS AND/OR COMBINATION FIRE/SMOKE DAMPERS IN DUCT PENETRATIONS
• PROVISION OF EMERGENCY LIGHTING
• PROVISION OF EMERGENCY POWER OFF SWITCH(ES) FOR ELECTRICAL POWER
• EMERGENCY OFF SWITCHES FOR HVAC; AND PROVISION OF A SEPARATE SPRINKLER ZONE FOR THE
DATA CENTER
LIFE SAFETY ANALYSIS:
THE WORK BEING PERFORMED AT THE VA CARIBBEAN HEALTH CARE SYSTEM IN SAN JUAN PUERTO RICO IS RENOVATION WITH SOME MINOR MODIFICATIONS THAT DO NOT AFFECT EGRESS OR EGRESS CAPACITY.
CHAPTER 19 – EXISTING CONTRUCTION IS THE APPLICABLE CODE SECTION APPLIED TO THE DESIGN REVIEW ALONG WITH CHAPTER 43 – BUILDING REHABILITATION. DATA CENTER CONSTRUCTION WILL BE
COMPLIANT WITH CHAPTER 38 – NEW BUSINESS.
THE IT CLOSETS AND DATA ROOMS ARE NON-OCCUPIED SPACE AND DO NOT ADD TO THE OCCUPANT LOAD.
THE ROOMS INCLUDED IN THIS PROJECT ARE NOT DEEMED HAZARDOUS AND DO NOT REQUIRE CHANGES TO THE FIRE/SMOKE BARRIERS. ADJACENT RATED BARRIERS TO THE IT ROOMS WILL BE REQUIRED TO BE MAINTAINED DURING THE PROJECT WITH COMPLIANT BARRIERS FREE FROM PENETRATIONS AT THE END
OF THE PROJECT.
THE DATA CENTER IS EVALUATED BASED ON OCCUPANCY LOAD AND EGRESS CAPACITY. THE DATA CENTER ROOM(S) ARE TO BE SEPERATED BY A (1) HR BARRIER AND TREATED AS A HAZARDOUS AREA.
CLEAN AGENT FIRE EXTINGUISHERS ARE TO BE LOCATED WITHIN 75 FEET OF EACH DATA ROOM AND
WITHIN THE DATA CENTER.
SPECIAL CARE SHOULD BE TAKEN TO CLEARLY IDENTIFY ALL FIRE/SMOKE BARRIERS THAT WILL BE AFFECTED BY THE REMOVAL/INSTALL OF CABLING. LIFE SAFETY DRAWINGS FOR BUILDINGS 1, 10, 19, 26, AND 30 ARE BEING PROVIDED BY THE VA AS A REFERENCE. ALL RATED BARRIERS THAT ARE PENETRATED
MUST BE REPAIRED WITH AN APPROVED UL FIRESTOP SYSTEM.
7.1.10 MEANS OF EGRESS RELIABILITY.
7.1.10.1* MAINTENANCE. MEANS OF EGRESS SHALL BE CONTINUOUSLY MAINTAINED FREE OF ALL
OBSTRUCTIONS OR IMPEDIMENTS TO FULL INSTANT USE IN THE CASE OF FIRE OR OTHER
EMERGENCY.
8.2.2.2 FIRE COMPARTMENTS SHALL BE FORMED WITH FIRE BARRIERS THAT COMPLY WITH
SECTION 8.3.
8.3 FIRE BARRIERS
8.3.1.1 FIRE BARRIERS USED TO PROVIDE ENCLOSURE, SUBDIVISION, OR PROTECTION UNDER THIS CODE SHALL BE CLASSIFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING FIRE RESISTANCE
RATINGS:
• (1) 3-HOUR FIRE RESISTANCE RATING
• (2) 2-HOUR FIRE RESISTANCE RATING
• (3) 1-HOUR FIRE RESISTANCE RATING
• (4)* 1⁄2-HOUR FIRE RESISTANCE RATING
8.3.1.2 FIRE BARRIERS SHALL COMPLY WITH ONE OF THE FOLLOWING:
• (1) THE FIRE BARRIERS ARE CONTINUOUS FROM OUTSIDE WALL TO OUTSIDE WALL OR FROM
ONE FIRE BARRIER TO ANOTHER, OR A COMBINATION THEREOF, INCLUDING CONTINUITY
THROUGH ALL CONCEALED SPACES, SUCH AS THOSE FOUND ABOVE A CEILING, INCLUDING
INTERSTITIAL SPACES.
• (2) THE FIRE BARRIERS ARE CONTINUOUS FROM OUTSIDE WALL TO OUTSIDE WALL OR FROM
ONE FIRE BARRIER TO ANOTHER, AND FROM THE FLOOR TO THE BOTTOM OF THE INTERSTITIAL
SPACE, PROVIDED THAT THE CONSTRUCTION ASSEMBLY FORMING THE BOTTOM OF THE
INTERSTITIAL SPACE HAS A FIRE RESISTANCE RATING NOT LESS THAN THAT OF THE FIRE
BARRIER.
9.2.1 AIR-CONDITIONING, HEATING, VENTILATING DUCTWORK, AND RELATED EQUIPMENT.
AIR-CONDITIONING, HEATING, VENTILATING DUCTWORK, AND RELATED EQUIPMENT SHALL BE IN ACCORDANCE WITH NFPA 90A OR NFPA 90B, AS APPLICABLE, UNLESS SUCH INSTALLATIONS ARE APPROVED EXISTING INSTALLATIONS, WHICH SHALL BE PERMITTED TO BE CONTINUED IN SERVICE.
19.1.1.4.3 REHABILITATION.
19.1.1.4.3.1 FOR PURPOSES OF THE PROVISIONS OF THIS CHAPTER, THE
FOLLOWING SHALL APPLY:
(2) A MINOR REHABILITATION SHALL INVOLVE THE MODIFICATION OF NOT MORE THAN 50 PERCENT, AND NOT MORE THAN 4500 FT2 (420 M2), OF THE AREA OF THE SMOKE COMPARTMENT.
19.1.1.4.3.2 WORK THAT IS EXCLUSIVELY PLUMBING, MECHANICAL, FIRE PROTECTION SYSTEM, ELECTRICAL, MEDICAL GAS, OR MEDICAL EQUIPMENT WORK SHALL NOT BE INCLUDED IN THE
COMPUTATION OF THE MODIFICATION AREA WITHIN THE SMOKE COMPARTMENT
19.2.2.2.4 DOORS WITHIN A REQUIRED MEANS OF EGRESS SHALL NOT BE EQUIPPED WITH A LATCH OR LOCK THAT REQUIRES THE USE OF A TOOL OR KEY FROM THE EGRESS SIDE, UNLESS OTHERWISE
PERMITTED BY ONE
OF THE FOLLOWING:
(1) LOCKS COMPLYING WITH 19.2.2.2.5 SHALL BE PERMITTED.
19.2.2.2.5.1* DOOR-LOCKING ARRANGEMENTS SHALL BE PERMITTED WHERE THE CLINICAL NEEDS OF
PATIENTS REQUIRE SPECIALIZED SECURITY MEASURES OR WHERE PATIENTS POSE A SECURITY
THREAT, PROVIDED THAT STAFF CAN READILY UNLOCK DOORS AT ALL TIMES IN ACCORDANCE WITH 19.2.2.2.6.
VA Caribbean Health Care System EHRM Life Safety Review (cont):
19.3 PROTECTION.
19.3.4.1 GENERAL. HEALTH CARE OCCUPANCIES SHALL BE PROVIDED WITH A FIRE ALARM SYSTEM IN
ACCORDANCE WITH SECTION 9.6.
19.3.5.1 BUILDINGS CONTAINING HEALTH CARE OCCUPANCIES SHALL BE PROTECTED THROUGHOUT BY AN APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 9.7, UNLESS OTHERWISE PERMITTED BY 19.3.5.5.
19.3.5.12 PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN ALL HEALTH CARE OCCUPANCIES
IN ACCORDANCE WITH SECTION 9.9.
19.3.6 CORRIDORS.
19.3.6.1 CORRIDOR SEPARATION. CORRIDORS SHALL BE SEPARATED FROM ALL OTHER AREAS BY PARTITIONS COMPLYING WITH 19.3.6.2 THROUGH 19.3.6.5 (SEE ALSO 19.2.5.4), UNLESS OTHERWISE
PERMITTED BY ONE OF THE FOLLOWING:
19.3.6.2 CONSTRUCTION OF CORRIDOR WALLS.
19.3.6.2.1 CORRIDOR WALLS SHALL BE PERMITTED TO TERMINATE AT THE CEILING WHERE THE
CEILING IS CONSTRUCTED TO LIMIT THE TRANSFER OF SMOKE.
19.3.6.2.2 NO FIRE RESISTANCE RATING SHALL BE REQUIRED FOR CORRIDOR WALLS.
19.3.6.2.3 CORRIDOR WALLS SHALL FORM A BARRIER TO LIMIT THE TRANSFER OF SMOKE.
19.3.6.3 CORRIDOR DOORS.
19.3.6.3.1 DOORS, INCLUDING DOORS OR PANELS TO NURSE SERVERS AND PASS-THROUGH
OPENINGS, PROTECTING CORRIDOR OPENINGS SHALL BE CONSTRUCTED TO RESIST THE PASSAGE
OF SMOKE, AND THE FOLLOWING ALSO SHALL APPLY:
(1) COMPLIANCE WITH NFPA 80 SHALL NOT BE REQUIRED.
(3) FOR DOORS PROTECTING PASS-THROUGH OPENINGS, A CLEARANCE BETWEEN THE BOTTOM OF
THE DOOR AND THE SILL NOT EXCEEDING 1⁄8 IN. (3 MM) SHALL BE PERMITTED.
19.3.6.3.11 DOOR-CLOSING DEVICES SHALL NOT BE REQUIRED ON DOORS IN CORRIDOR WALL
OPENINGS OTHER THAN THOSE SERVING REQUIRED EXITS, SMOKE BARRIERS, OR ENCLOSURES OF
VERTICAL OPENINGS AND HAZARDOUS AREAS.
CHAPTER 43 BUILDING REHABILITATION
43.1.3 MULTIPLE REHABILITATION WORK CATEGORIES
43.1.3.1 WORK OF MORE THAN ONE REHABILITATION WORK CATEGORY SHALL BE PERMITTED TO BE
PART OF A SINGLE WORK PROJECT.
43.1.3.2 WHERE A PROJECT INCLUDES ONE CATEGORY OF REHABILITATION WORK IN ONE BUILDING AREA AND ANOTHER CATEGORY OF REHABILITATION WORK IN A SEPARATE AREA OF THE BUILDING, EACH PROJECT AREA SHALL COMPLY WITH THE REQUIREMENTS OF THE RESPECTIVE CATEGORY OF
REHABILITATION WORK.
43.1.3.3 WHERE A PROJECT CONSISTING OF MODIFICATION AND RECONSTRUCTION IS PERFORMED IN THE SAME WORK AREA, OR IN CONTIGUOUS WORK AREAS, THE PROJECT SHALL COMPLY WITH THE REQUIREMENTS APPLICABLE TO RECONSTRUCTION, UNLESS OTHERWISE SPECIFIED IN 43.1.3.4.
43.1.3.4 WHERE THE RECONSTRUCTION WORK AREA IS LESS THAN 10 PERCENT OF THE
MODIFICATION WORK AREA, THE TWO SHALL BE CONSIDERED INDEPENDENT WORK AREAS, AND THE
RESPECTIVE REQUIREMENTS SHALL APPLY.
43.1.4COMPLIANCE
43.1.4.1 REPAIRS, RENOVATIONS, MODIFICATIONS, RECONSTRUCTION, CHANGES OF USE OR
OCCUPANCY CLASSIFICATION, AND ADDITIONS SHALL CONFORM TO THE SPECIFIC REQUIREMENTS
FOR EACH CATEGORY IN OTHER SECTIONS OF THIS CHAPTER.
43.2 REPAIRS
43.2.1 GENERAL REQUIREMENTS
43.3.1.1 A REPAIR, AS DEFINED IN 43.2.2.1.1, IN OTHER THAN HISTORIC BUILDINGS SHALL COMPLY
WITH THE REQUIREMENTS OF SECTION 43.3.
43.3.1.3 THE WORK SHALL BE DONE USING LIKE MATERIALS OR MATERIALS PERMITTED BY OTHER
SECTIONS OF THIS CODE.
43.3.1.4 THE WORK SHALL NOT MAKE THE BUILDING LESS CONFORMING WITH THE OTHER SECTIONS OF THIS CODE, OR WITH ANY PREVIOUSLY APPROVED ALTERNATIVE ARRANGEMENTS, THAN IT WAS
BEFORE THE REPAIR WAS UNDERTAKEN.
43.4 RENOVATIONS
43.4.1.3 ALL NEW WORK SHALL COMPLY WITH THE REQUIREMENTS OF THIS CODE APPLICABLE TO
EXISTING BUILDINGS.
43.4.1.4 THE WORK SHALL NOT MAKE THE BUILDING LESS CONFORMING WITH OTHER SECTIONS OF
THIS CODE, OR WITH ANY PREVIOUSLY APPROVED ALTERNATIVE ARRANGEMENTS, THAN IT WAS
BEFORE THE RENOVATION WAS UNDERTAKEN, UNLESS OTHERWISE SPECIFIED IN 43.4.1.5.
43.4.1.5 MINOR REDUCTIONS IN THE CLEAR OPENING DIMENSIONS OF REPLACEMENT DOORS AND WINDOWS THAT RESULT FROM THE USE OF DIFFERENT MATERIALS SHALL BE PERMITTED UNLESS
SUCH REDUCTIONS ARE PROHIBITED.
43.4.2 CAPACITY OF MEANS OF EGRESS THE CAPACITY OF MEANS OF EGRESS, DETERMINED IN
ACCORDANCE WITH SECTION 7.3, SHALL BE SUFFICIENT FOR THE OCCUPANT LOAD THEREOF,
UNLESS ONE OF THE FOLLOWING CONDITIONS EXISTS:
(2) *THE EGRESS CAPACITY SHALL HAVE BEEN PREVIOUSLY APPROVED AS BEING ADEQUATE.
43.4.3 INTERIOR FINISH REQUIREMENTS NEW INTERIOR FINISH MATERIALS SHALL MEET THE
REQUIREMENTS FOR NEW CONSTRUCTION.
43.4.4 OTHER REQUIREMENTS THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE
INSTALLATION OF ANY ADDITIONAL EQUIPMENT, SHALL COMPLY WITH SECTION 43.5.
43.5 MODIFICATIONS
43.5.1GENERALREQUIREMENTS
43.5.1.1 A MODIFICATION, AS DEFINED IN 43.2.2.1.3, IN OTHER THAN HISTORIC BUILDINGS SHALL
COMPLY WITH BOTH OF THE FOLLOWING:
(1) SECTION 43.5
(2) SECTION 43.4
43.5.1.3 NEWLY CONSTRUCTED ELEMENTS, COMPONENTS, AND SYSTEMS SHALL COMPLY WITH THE
REQUIREMENTS OF OTHER SECTIONS OF THIS CODE APPLICABLE TO NEW CONSTRUCTION.
VA Caribbean Health Care System EHRM Life Safety Review (cont):
NFPA 241, 2019 - SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS
8.6.2.1 PROTECTION SHALL BE PROVIDED TO SEPARATE AN OCCUPIED PORTION OF THE STRUCTURE FROM A PORTION OF THE STRUCTURE UNDERGOING ALTERATION, CONSTRUCTION, OR DEMOLITION OPERATIONS WHEN SUCH OPERATIONS ARE CONSIDERED AS HAVING A HIGHER LEVEL OF HAZARD
THAN THE OCCUPIED PORTION OF THE BUILDING.
8.6.2.1.1 WALLS SHALL HAVE AT LEAST A 1-HOUR FIRE RESISTANCE RATING.
8.6.2.1.2 OPENING PROTECTIVES SHALL HAVE AT LEAST A 45-MINUTE FIRE PROTECTION RATING.
8.6.2.2 WALLS IN 8.6.2.1.1 AND OPENING PROTECTIVES IN 8.6.2.1.2 SHALL BE PERMITTED TO BE NONRATED WHEN AN APPROVED AUTOMATIC SPRINKLER SYSTEM IS INSTALLED AND OPERATIONAL.
TR ROOMS AND THE DATA CENTER IS CONSIDERED TO BE UNOCCUPIED SPACE; A BUILDING SERVICE EQUIPMENT SUPPORT AREA IN WHICH PEOPLE ARE NOT EXPECTED TO BE PRESENT ON A REGULAR BASIS.
**IF FLOOR OR RATED WALL PENETRATIONS CANNOT BE FIRESTOPPED AT THE END OF THE
WORK SHIFT DUE TO THE NEED TO PULL ADDITIONAL CABLES, TEMPORARY FIRESTOPPING COMPOSED OF MINERAL WOOL SHOULD BE INSTALLED IN THE PENETRATION TO PROVIDE PROTECTION AGAINST
FIRE/SMOKE SPREAD THROUGH THE UNSEALED PENETRATION. **
**ALL RATED BARRIER PENETRATIONS ARE TO BE REPAIRED WITH AN APPROVED UL SYSTEM**
** CONSTRUCTION AREAS MUST BE SEPARATED FROM THE SURROUNDING OCCUPIED AREAS UNLESS THE
WORK IS NO MORE HAZARDOUS THAN NORMAL OPERATIONS. PULLING CABLING WOULD NOT BE
CONSIDERED HAZARDOUS BUT THE DEMOLITION ASSOCIATED WITH CREATING OR EXPANDING TRS NAY BE. THIS MUST BE APPROVED BY THE AHJ (VISN SAFETY ENGINEER) IF THIS IS THE DESIGN BASIS. **
**EVEN IF THE WORK IS HAZARDOUS, IT IS ACCEPTABLE TO USE NON-RATED BARRIERS (PLASTIC SHEETING) FOR CONSTRUCTION AREA SEPARATION IF THE SPRINKLERS WITHIN THE CONSTRUCTION AREA BEING OPERABLE. REMOVAL OF MORE THAN ONE CEILING TILE WITHIN THE PROTECTION AREA OF A SPRINKLER CAN RENDER THE SPRINKLER INEFFECTIVE DUE TO HEAT ENTERING THE CEILING PLENUM AND
BYPASSING THE SPRINKLER. **
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
421 King ST Suite 301 Alexandria, VA 22314 703-772-4213
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
LIFE SAFETY REVIEW
LS100
2-
-7
. L
S1
. 1 0/
/2
0.
pd f
M L
EXIST.
C
H
ASE
JANITOR
3107.1
UTLITIES SHAFT
#2
EXISTING
SERVICE
ELVATOR
EXISTING
SERVICE
ELEVATOR
EXISTING STAIR
#2
EXISTING
CHASE
EXISTING
ELECTRICAL
CLOSET
3000.4
SHELL SPACE
FUTURE
COMPUTER
ROOM
J-1C
TR
BLACK
OUT
FILM
BLACK
OUT
FILM
BLACK
OUT
FILM
BLACK
OUT
FILM
BLACK OUT
FILM
BLACK OUT
FILM
BLACK OUT
FILM
BLACK OUT
FILM
NEW SIGN
NEW SIGN
NEW SIGN
PATH TO EXIT 73'-3"
REQUIRED TRAVEL DISTANCE:
UNDER 200'-0"
FEC
FIRE
PROTECTION
ROOM
3100.4b
STORAGE
ROOM
3100.4a
CODE ANALYSIS LEGEND
1 HOUR FIRE BARRIER PER NFPA 101 8.6 /
19.3.2.1.2. OPENINGS FIRE RATED FOR 45
MINUTES UNLESS SHAFT, EXIT ENCLOSURE, OR
EXIT PASSAGEWAY WALLS WHICH REQUIRE 1
HOUR RATED OPENINGS.
2 HOUR FIRE BARRIER PER NFPA 101 8.2.
OPENINGS FIRE RATED FOR 90 MINUTES.
EGRESS PATH WITH NAME, SEGMENT LENGTH,
AND DIRECTION INDICATEDPATH A
OPENING RATING IN MINUTES
OPENING RATING IN MINUTES
FEC FIRE EXTINGUISHER CABINET
EXIT SIGN
SMOKE BARRIER PER NFPA 101 19.3.7.3.
OPENINGS FIRE RATED FOR 20 MIN.20
OPENING RATING IN MINUTES
NEW DATA CENTER
EXIT 2A
EXIT 2
EXIT 1
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
421 King ST Suite 301 Alexandria, VA 22314 703-772-4213
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
BUILDING 1 - MAIN BUILDING - THIRD
FLOOR LIFE SAFETY PLAN
01-LS103
2-
-7
. 0
1-
LS
3.
1/
/2
3.
pd f
1/4" = 1'-0"1 BUILDING 1 - MAIN BUILDING - THIRD FLOOR LIFE SAFETY PLAN
N
SITE KEY PLAN
TRUE NORTH
1/16" = 1'-0"2 BUILDING 1 - MAIN BUILDING - EXISTING THIRD FLOOR
UNOCCUPIED SPACE
1D168b
1D168
1D164
1D168c
1D168a
1D161b
1D161 1D161a C1-1B
DISHWASHING
W. TOIL
LOBBY
TERAPY
PHYSICAL
DIETETIC
STO.
ROOM
TERAPIST
HYD
O.T. CLINIC
N.H.C.U.
STO.
STO.
SECRETARY
AND WAITING
AREA
C M
E
LE
C
R O O M
C O M
R O O M
H O U S E
K E E P
IN
G
PAT . R
O
O M
# 1
PAT . R
O
O M
# 2
PAT . R
O
O M
# 3
PAT . R
O O
M # 15
PAT . R
O
O M
# 16
PAT . R
O
O M
# 17
S
TA
F F
TO
I.
M A L E
S
TA
F F
TO
I.
F E M
B
IO
M E D
W A S T
1H-1 00
1H-1 00a
1H-1 01
1H-1 02
1H-1 01a
1H-1 22
1H-1 23
1H-1 24
1H-1 35 1H-1 36
1H-1 37
1H-1 38 1H-1 39
1H-1 39a
1H-1 25 1H-1 34
1H-1 26
1H-1 27 1H-1 32
1H-1 33
CO
R RIDO
R C -___
S U R G
IC
A L
S
TO
R A G E
D G S F
P
2A104
2A123
2B125
2B126 2A109
2A108
2A106
2A112
2A110
2A124
2A111
2A113
2A114
2A122
2A121
2A115
2A116
2A117
2A120
2A119
2A118
2A107 2A105
C
TERRACE
CARE
HOME
STAFF
COMMON
CLEAN
BATHROOM
BATH
LINEN
HEAD
NURSE
KITCHEN
H.K.PHARMACY
NURSE
KITCHEN
NURSE
BATHROOM
ELEC.
BEDROOM
TWO BED
TWO BED
BEDROOM
BEDROOM
TWO BED
BEDROOM
TWO BED
TWO BED
BEDROOM
BEDROOM
TWO BED
TWO BED
BEDROOM
ONE BED
BEDROOM
ONE BED
BEDROOM
BEDROOM
ONE BED
# 1
BEDROOM
ONE BED
H.A.C.
TOIL.
STAIR
CODE ANALYSIS LEGEND
1 HOUR FIRE BARRIER PER NFPA 101 8.6 /
19.3.2.1.2. OPENINGS FIRE RATED FOR 45
MINUTES UNLESS SHAFT, EXIT ENCLOSURE, OR
EXIT PASSAGEWAY WALLS WHICH REQUIRE 1
HOUR RATED OPENINGS.
2 HOUR FIRE BARRIER PER NFPA 101 8.2.
OPENINGS FIRE RATED FOR 90 MINUTES.
EGRESS PATH WITH NAME, SEGMENT LENGTH,
AND DIRECTION INDICATEDPATH A
OPENING RATING IN MINUTES
OPENING RATING IN MINUTES
FEC FIRE EXTINGUISHER CABINET
EXIT SIGN
SMOKE BARRIER PER NFPA 101 19.3.7.3.
OPENINGS FIRE RATED FOR 20 MIN.20
OPENING RATING IN MINUTES
TR
1C1-1B
SMOKE COMPARTMENT
SC1-1 = 22,171SF
OCCUPANT PER SF = 240
MAX OCCUPANT LOAD = 93
PATH TO EXIT 30'-5"
REQUIRED DISTANCE:
UNDER 200'-0"
VESTIBULE
1C1-1A
ELECTRIC
ROOM
1A102
UNOCCUPIED
SPACE
TR
1H-140
PA
TH
T O
E
XI
T
'-2
R
EQ
U
IR
ED
D
IS
TA
N C
E:
U N
D
ER
'-0
UNOCCUPIED
SPACE
SMOKE COMPARTMENT
SC1-1 = 8,906SF
OCCUPANT PER SF = 120
MAX OCCUPANT LOAD = 75
TR
2A104b
OFFICE
2A104a
HOME CARE
2A104
ELECTRIC
ROOM
2A102
PATH TO EXIT 196'-2"
REQUIRED DISTANCE:
UNDER 200'-0"
UNOCCUPIED
SPACE
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
950 N.
WASHINGTON ST
SUITE 334
ALEXANDRIA, VA
22314
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
BUILDING 10 AND 26 LIFE SAFETY
PLANS
10-LS100
2-
-7
. 1
0-
LS
0.
1/
/2
3.
pd f
N
SITE KEY PLAN
TRUE NORTH
1/8" = 1'-0"2 BUILDING 10 - NURSING HOME CLC - FIRST FLOOR LIFE SAFETY PLAN
1/8" = 1'-0"1 BUILDING 26 - FIRST FLOOR LIFE SAFETY PLAN
1/8" = 1'-0"3 BUILDING 10 - NURSING HOME CLC - SECOND FLOOR LIFE SAFETY PLAN
FEC
FEC
FEC
UP
DN
PHPSYCH.
CONF./CLASS
PHARMACY
H.NURSES
PSYCHOLOGIST
Y
OVE
BATH
ANTERM.
M T
TATION
DAY RM.
RECREATION, DINING
SOIL. UT. NURS.
SUPERV.
TEL.
STAFF
TOIL. STORAGE
VISIT. WAIT
FIM. V
TOILE
1-BED IS. (1)
SECLUSION
VESTIBULE
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
RECYC.
2-BED (6) 2-BED (7)
BATHBATH
J-2210
J-2208
K-2209
K-2268B
K-2287A
K-2287B
J-2
K-2298
K-2292 K 2295
K-2289
K-2297 K-2298A
J-2253
J-2253
K-2287
J-2253A
C2-3
C2-14
C3-11
C2-2
J-C29A
K-2288 K-2290
K-2290AK-2288A
S2-3 x;Sx;S
FEC
FEC
STAIR
S1-3
CASE
MNGR OFF
CLINIC
NURSES SPEC. H.NURSE
SOIL.UT.
K-1198
ART.
28 NURSES
STA.
M. TLT.
J-1113
F.TLT.
J-1115
DIETARY
CART ALCOVE
C1-12B
CORRIDOR
C1-12A
CORRIDOR
CORRIDOR
C1-3
PASSAGE
C1-15
ELECT.
K-1224BOWEL CARE/
SH. EQ.STOR.
K-1223
PHYSICIAN
K-1229
ISOLATION
ROOM (2)
K-1219
ANTERM.(2)
K-1219B
TEL.
K-1226
KITCH.
K-1225B
DINING
K-1225
DAYROOM
K-1225A
SCI DIET.
K-1111
SCI PHARM.
K-1110
SCI SEC'Y.
K-1109
SCI
ADMIN.
K-1107
SCI CHIEF
OFF.
K-1108
STAFF MEET
& CONF.
J-1106
M. STAFF
LOCKERS
J-1112
(MICU)
VISIT. WAIT.
J-1116
CORRIDOR
C1-2
UP
DN
ALCOVE
CRASH CART
x;Sx;S
DINING
PSYCH.
CON
DIETITIAN
PHARMACY
QUIET RM.
SOC. WORK.
NOURISH.
H.NURSES
PHYSICIAN
CONSUL.
M.PREP.
DIETARY
CART ALCOVE
NURSES
STATION
F.VISIT.
TOIL.
1-BED (4) 1-BED (5)
H BATH BATH
EQUIP STOR
1-BED IS. (1)
ANTERM.
TEL.
CORRIDOR
CORRIDOR
CO
CO
CORRIDOR
J-3312
J-3310
K-3398B
K-3309
K-3398A
K-3398
K-3397 K-3398D
K-3398C
K-3359B
C3-15B
K-3356
K-3392 K-3394
2A K-3394A K-3396A
K-3396
K-3396B
K-3395
C3-15
C3-2C3-16
S3-3
STAIR
x;Sx;S
VISIT.W
SOC. WORK.
CONF./CLA
DIETITIAN
PHARMACY
QUIET RM.
SOC. WORK.
H.NURSES
PHYSICIAN
CONSUL. CORRIDOR
CORRID
CORRID
CORRIDOR
NOURISH.
M.PREP.
DIETARY
CART ALCOVE
NURS.
STATION
(3) 1-BED IS.(4)
BATH BATH
M. ANTERM.
TEL.
F.VISIT.
TOIL.
J-44
J-4410
J-440
K-44100
K-4409
K-4499
K-4498
K-44102
K-44101 C4-2
C4-3
C4-10
C4-16
K-4494
K-4459B
C4-15C
K-4493
K-4491A K-4493A
B K-4493B
K-4492
K-4456
STAIR
S4-3 x;Sx;S
C
PHYSIC
J-55
STAIR
S5-3
CORRIDOR
C5-16
CORRIDOR
C5-2
TEL.
K-5592
ANTERM.
K-5593B
BATH
K-5593A
BATH
K-5591A
1-BED IS.(4)
K-5593
F.VISIT.
TOIL.
K-5556NURS.
STATION
DIETARY
CART ALCOVE
C5-15C
M.PREP.
K-5559B
PHYSICIAN
CONSUL.
K-5598
H.NURSES
K-5599
NOURISH.
K-5594
SOC. WORK.
K-5595
DAYRM. RECR.
K-5596
PHARMACY
K-5509
DIETITIAN
K-5597 x;Sx;S
FEC
FEC
CORRIDOR
C6-16 CORRIDOR
C6-2
TEL.
K-6692
ANTERM.
K-6693B
M.
B
BATH
K-6693A
BATH
K-6691A
1-BED IS.(4)
K-6693
S.(3)
F.VISIT.
TOIL.
NURS
DIETARY
CART ALCOVE
C6-15C
M.PREP.
K-6659B
PHYSICIAN
CONSUL.
K-6698
H.NURSES
K-6699NOURISH.
K-6694
SOC. WORK.
K-6695
DAYRM. RECR.
K-6696
PHARMACY
K-6609
DIETITIAN
K-6697
PHYSICIAN
J-6610
STAIR
S6-3
48x48 Tackboard
4 T
FUT
S3x;Sx;S
CORR
CODE ANALYSIS LEGEND
1 HOUR FIRE BARRIER PER NFPA 101 8.6 /
19.3.2.1.2. OPENINGS FIRE RATED FOR 45
MINUTES UNLESS SHAFT, EXIT ENCLOSURE, OR
EXIT PASSAGEWAY WALLS WHICH REQUIRE 1
HOUR RATED OPENINGS.
2 HOUR FIRE BARRIER PER NFPA 101 8.2.
OPENINGS FIRE RATED FOR 90 MINUTES.
EGRESS PATH WITH NAME, SEGMENT LENGTH,
AND DIRECTION INDICATEDPATH A
OPENING RATING IN MINUTES
OPENING RATING IN MINUTES
FEC FIRE EXTINGUISHER CABINET
EXIT SIGN
SMOKE BARRIER PER NFPA 101 19.3.7.3.
OPENINGS FIRE RATED FOR 20 MIN.20
OPENING RATING IN MINUTES
PA
TH
T O
E
XI
T
9' -7
R
EQ
U
IR
ED
D
IS
TA
N
D
ER
'-0
TR
K-2298A
SMOKE COMPARTMENT
SC2-2 = 13,182SF
OCCUPANT PER SF = 120
MAX OCCUPANT LOAD = 110
TR
K-1225C
SMOKE COMPARTMENT
SC1-2 = 17,663SF
OCCUPANT PER SF = 120
MAX OCCUPANT LOAD = 148
PATH TO EXIT 28'-10"
REQUIRED DISTANCE:
UNDER 200'-0"
TR
K-3398B
PA
TH
T O
E
XI
T
3' -1
1" R
EQ
U
IR
ED
D
IS
TA
N
D
ER
'-0
SMOKE COMPARTMENT
SC3-2 = 13,453SF
OCCUPANT PER SF = 120
MAX OCCUPANT LOAD = 113
TR
K-3399A
PA
TH
T O
E
XI
T
3' -1
1" R
EQ
U
IR
ED
D
IS
TA
N
D
ER
'-0
SMOKE COMPARTMENT
SC4-2 = 16,709SF
OCCUPANT PER SF = 120
MAX OCCUPANT LOAD = 140
TR
K-5596A
PA
TH
T O
E
XI
T
3' -1
1" R
EQ
U
IR
ED
D
IS
TA
N
D
ER
'-0
SMOKE COMPARTMENT
SC5-2 = 16,710SF
OCCUPANT PER SF = 120
MAX OCCUPANT LOAD = 140
TR
K-6696A
PA
TH
T O
E
XI
T
3' -1
1" R
EQ
U
IR
ED
D
IS
TA
N
D
ER
'-0
SMOKE COMPARTMENT
SC6-2 = 16,716SF
OCCUPANT PER SF = 120
MAX OCCUPANT LOAD = 140
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
950 N.
WASHINGTON ST
SUITE 334
ALEXANDRIA, VA
22314
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
BUILDING 30 - SOUTH BED TOWER -
LIFE SAFETY PLANS
30-LS100
2-
-7
. 3
0-
LS
0.
1/
/2
3.
pd f
N
SITE KEY PLAN
TRUE NORTH
1/8" = 1'-0"2 BUILDING 30 - SOUTH BED TOWER - SECOND FLOOR LIFE SAFETY PLAN
1/8" = 1'-0"1 BUILDING 30 - SOUTH BED TOWER - FIRST FLOOR LIFE SAFETY PLAN
1/8" = 1'-0"3
BUILDING 30 - SOUTH BED TOWER
THIRD FLOOR LIFE SAFETY PLAN
1/8" = 1'-0"4 BUILDING 30 - SOUTH BED TOWER - FOURTH FLOOR LIFE SAFETY PLAN
1/8" = 1'-0"5 BUILDING 30 - SOUTH BED TOWER - FIFTH FLOOR LIFE SAFETY PLAN
1/8" = 1'-0"6 BUILDING 30 - SOUTH BED TOWER - SIXTH FLOOR LIFE SAFETY PLAN
UNOCCUPIED
SPACE
UNOCCUPIED
SPACE UNOCCUPIED
SPACE
UNOCCUPIED
SPACE UNOCCUPIED
SPACE
UNOCCUPIED
SPACE
VA Project Number:
Building:
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
950 N.
WASHINGTON ST
SUITE 334
ALEXANDRIA, VA
22314
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
CAMPUS REFERENCE
LS.01-REF
2-
-7
. L
S.
-R
EF
. 0 1/
/2
3.
pd
FOR REFERENCE ONLY
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
421 King ST Suite 301 Alexandria, VA 22314 703-772-4213
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
LEVEL ONE LIFE SAFETY PLAN
REFERENCE
LS.1.1.1-REF
2-
-7
. L
S.
1.
1.
1-
R
EF
. 0 1/
/2
3.
pd f
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
950 N.
WASHINGTON ST
SUITE 334
ALEXANDRIA, VA
22314
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
LEVEL ONE LIFE SAFETY PLAN
REFERENCE
LS.1.1.2-REF
2-
-7
. L
S.
1.
1.
2-
R
EF
. 0 1/
/2
3.
pd f
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
950 N.
WASHINGTON ST
SUITE 334
ALEXANDRIA, VA
22314
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
LEVEL TWO LIFE SAFETY PLAN
REFERENCE
LS.1.2.1-REF
2-
-7
. L
S.
1.
2.
1-
R
EF
. 0 1/
/2
3.
pd f
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
950 N.
WASHINGTON ST
SUITE 334
ALEXANDRIA, VA
22314
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
LEVEL TWO LIFE SAFETY PLAN
REFERENCE
LS.1.2.2-REF
2-
-7
. L
S.
1.
2.
2-
R
EF
. 0 1/
/2
3.
pd f
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
950 N.
WASHINGTON ST
SUITE 334
ALEXANDRIA, VA
22314
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
BASEMENT LEVEL LIFE SAFETY PLAN
REFERENCE
LS.1.B.1-REF
2-
-7
. L
S.
1.
B.
1-
R
EF
. 0 1/
/2
3.
pd f
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
950 N.
WASHINGTON ST
SUITE 334
ALEXANDRIA, VA
22314
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
BASEMENT LEVEL LIFE SAFETY PLAN
REFERENCE
LS.1.B.2-REF
2-
-7
. L
S.
1.
B.
2-
R
EF
. 0 1/
/2
3.
pd f
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
950 N.
WASHINGTON ST
SUITE 334
ALEXANDRIA, VA
22314
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
LIFE SAFETY ASSESSMENT
PARTITION LEGENDS & APPLICABLE
CODES REFERENCE
LS.02-REF
2-
-7
. L
S.
-R
EF
. 0 1/
/2
3.
pd
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
950 N.
WASHINGTON ST
SUITE 334
ALEXANDRIA, VA
22314
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
COMPARTMENT CALCULATIONS,
SUITES, BLDG. SQUARE FOOTAGE
REFERENCE
LS.03-REF
2-
-7
. L
S.
-R
EF
. 0 1/
/2
3.
pd
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
421 King ST Suite 301 Alexandria, VA 22314 703-772-4213
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
LEVEL ONE LIFE SAFETY PLAN
REFERENCE
LS.10.1-REF
2-
-7
. L
S.
.1 -R
EF
. 0
1/
/2 3.
pd f
Drawing Number:
Project Title:
Project Location:
Issue Date:
Checked By: Drawn By:
Drawing Title:
FULLY
SPRINKLER
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
A
Submission:
ARCHITECT / ENGINEER OF RECORD:
Revisions: Date:
CONSULTANTS:
/8
'-0
4 '
8 ' 6 '
/4
'-0
/8
'-0
/2
'-0
/4
'-0
'-0
-1
/2
'-0
'-0
CONSULTANT:
Compass Consulting Group 3401 enterprise Parkway Suite 301 Beachwood, OH 44122
ARCHITECT:
CB DESIGN GROUP
950 N.
WASHINGTON ST
SUITE 334
ALEXANDRIA, VA
22314
PROFESSIONAL SEAL:
VA Caribbean Health Care System 10 Calle Casia San Juan Puerto Rico
2345678910111213141516
B
C
D
E
F
G
H
I
J
12345678910111213141516
CONSULTANT:
Integrity Federal Services 148 S. Queen Street Suite 201
CONSULTANT:
IMEG
15 Sunnen Drive Suite St. Louis, MO 63143
12 / 11 / 2023
672-21-700
AuthorChecker
EHRM INFRASTRUCTURE UPGRADE
SAN JUAN PR
BID DOCUMENTS SUBMISSION
LEVEL TWO LIFE SAFETY PLAN
REFERENCE
LS.10.2-REF
2-
-7
. L
S.
.2 -R
EF
. 0
1/
/2 3.
pd f