Attachment 4 - Drawing A301 Building Elevations 21JUN2007.pdf

PDF 257 KB Posted

Attached to
Building 229 Roofing System Replacement Federal contract opportunity
Solicitation number
12305B23R0022
Issued by
Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery Northeast Area

About this file

This drawing package contains construction drawings for a new poultry facility at the USDA Agricultural Research Center in Beltsville, Maryland. The drawings show building elevations for the breeder wing, grow out wing, and service area. Key details include roof assembly specifications with asphalt/fiberglass shingle roofing and pre-finished metal gutters. Masonry piers and evaporative cooling pads are noted. Exterior finishes comprise concrete walls with acrylic sealer and CMU with acrylic sealer.

The related federal contract opportunity is a solicitation from the USDA Agricultural Research Service Northeast Area to replace the roofing system on Building 229. The solicitation number is 12305B23R0022.

View the file

Other files for this federal contract opportunity

Other files attached to Building 229 Roofing System Replacement, newest first.
File Type Posted
12305B23R00220001.pdf PDF
12305B23R0022.pdf PDF
Attachment 8 - Drawing M602 HVAC Control Diagrams 21JUN2007.pdf PDF
Attachment 14 - USDA Forms - 02AUG2023.pdf PDF
Attachment 16 - WD Prince George s County MD Building MD20230044 04AUG2023.pdf PDF
Attachment 1 - Division 1 USDA General Requirements - B229 Roofing System Replacement - 16AUG2023.pdf PDF
Attachment 2 - Drawing A201 Breeder and Grow Out Wings Partial Floor Plan 21JUN2007.pdf PDF
Attachment 7 - Drawing A402 Building Sections 21JUN2007.pdf PDF
Attachment 11 - Drawing P204 Roof Plan 21JUN2007.pdf PDF
Attachment 12 - Drawing A202 Service Area Partial Floor Plan 21JUN2007.pdf PDF
Attachment 3 - Drawing A401 Building And Wall Sections 21JUN2007.pdf PDF
Attachment 6 - Drawing A203 Building Roof Plan 21JUN2007.pdf PDF
Attachment 9 - Drawing M701 HVAC Details 21JUN2007.pdf PDF
Attachment 10 - Drawing M801 Mechanical Equipment Schedules 21JUN2007.pdf PDF
SOW - B229 Roofing System Replacement - 16AUG2023.pdf PDF
Attachment 5 - Drawing A302 Building Elevations 21JUN2007.pdf PDF
Attachment 13 - Open Flame Policy and Permit - 16AUG2023.pdf PDF
Attachment 15 - Submittal Registry - B229 Roofing System Replacement - 16AUG2023.pdf PDF
Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Drawing No.:

Drawing Title:

Date:

Issues:

F5W51104

A

B

C

D

1 2 3 4 5

1 2 3 4 5

Jacobs Project No.:

Designed By:

Drawn By:

Checked By:

Project No:

02-21-03

EPM:

RPM:

Safety & Health:

Real Property:

JFI

FINAL TURNOVER

B. Runser

C. Joyner

DR. McMurty

06-21-07 FINAL RECORD DRAWING

FACILITIES INC.

R

1100 NORTH GLEBE ROAD, SUITE 500, ARLINGTON, VIRGINIA 22201

JUNE 6, 2007

USDA-ARS

C. Harris Proj. Manager:

D e s ig n o f A

N e w

P o u lt ry F a c il it y

B e lt s v il le

A g ri c u lt u ra l

R e s e a rc h C e n te r

US

DA

AR

S

JACOBS

A C E G J L

B D F H K L

J L A C E G

B D F H K L

0 4 621m 3 5 7 8

1:100 A301

A1

A301 A202

SCALE 1:100

BREEDER WING NORTH ELEVATION

C1

BREEDER WING SOUTH ELEVATION

D1

GROW OUT WING SOUTH ELEVATION

GENERAL NOTES

TOP OF RIDGE

ELEV. 45 000

TOP OF CONC. SLAB

TOP OF RIDGE

ELEV. 45 000

TOP OF CONC. SLAB

TOP OF RIDGE

ELEV. 45 000

TOP OF CONC. SLAB

TOP OF RIDGE

ELEV. 45 000

TOP OF CONC. SLAB

KEYED NOTES

10 PVC RESERVOIR

11 BULK FEEDER ON CONC. PAD

TOP OF CMU

TOP OF CMU

TOP OF CMU

TOP OF CMU

B1

GROW OUT WING NORTH ELEVATION

TYP.

6 7

TYP.

11 2

TYP.

8 8

CMU W/ ACRYLIC SEALER

CONC. WALL WITH ACRYLIC SEALER

14 CONC. CURB TYP. WHERE NO KNEE WALL

TYP. ROOF ASSEMBLY

TYP.

TYP.

13 TYP.

ELEV. 50 740

ELEV. 50 740

ELEV. 50 740

ELEV. 50 740

TYP.

TYP.

TYP.

TYP.

TYP.

TYP. TYP. 15

TYP.

TYP.

TYP.

1 10

TYP.

FINISH GRADE-REFER CIVIL

PRE FINISHED METAL GUTTER W/ DOWN SPOUTS- TYP.

DOWN SPOUT DOWN TO STORM SYSTEM - CONNECT

UNDERGROUND

1 1 1 1

TYP.

TYP. TYP. TYP.

DASHED LINES INDICATE

PIPING AND GUTTER

SYSTEM FOR COOLING

PADS - TYP

TYP.4

TYP. TYP.

TYP.

1 1

TYP.

1 1 1 1 1 1

1 1 1 1 1 1

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

ELEV. 48 251

ELEV. 48 251

ELEV. 48 251

ELEV. 48 251

1. REFERENCE ELEVATION 45 000 AT TOP CONCRETE

SLAB - REFER TO CIVIL DWGS.

TYP.

MASONRY PIERS TYP. AT COOLING PAD OPENINGS -

REFER TO STRUCTURAL

EVAPORATIVE COOLING PAD - REFER MECHANICAL

AND STRUCTURAL FOR MASONRY PIERS

ASPHALT/ FIBERGLASS SHINGLE ROOFING

PRE FINISHED METAL DOWN SPOUT W/ CONC.

SPLASH BLOCK

150MM DIAMETER PAINTED STEEL BOLLARD

REFER TO DETAIL C2/A402

RIDGE VENT

TYP.

TYP.

TYP.

TYP.

EXHAUST FAN-TYP. REFER TO MECH. DWG.

BUILDING

ELEVATIONS

G. Lindberg

C. Rhee

G. Lindberg

MASONRY CONTROL JOINT EACH SIDE OF OPENING

- 7 620 MAX - OFFSET AT LINTELS. REFER TO

D2/A402

Key Plan:

BREEDER WING

SERVICE AREA

GROW OUT WING

17 SNOW GUARD