This document package includes room data sheets and specifications for the proposed Honor Guard Building at the Western New York National Cemetery in Pembroke, New York. The solicitation is for a major construction project to build Phase 1C of the cemetery maintenance complex. The Department of Veterans Affairs Office of Construction and Facilities Management is the contracting agency.

The room data sheets provide requirements for 11 spaces within the Honor Guard Building, including dimensions, functions, finishes, fixtures, equipment, and technical specifications. Spaces outlined include an honor guard room, locker room, storage, mechanical room, men's and women's toilets, closet, vault, and passage areas. Mechanical, electrical, plumbing, fire protection, security and telecommunications specifications are identified by Uniformat section for each room.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Western New York National Cemetery Phase 1C Maintenance Complex Design Build RFP 936-002C Pembroke, NY 3.6.1 Honor Guard Building

PART 3 - CHAPTER 6 - Page 1

3.6.1 Honor Guard Building- Room Requirements

3.6.1 Honor Guard - Room Requirements

B-100 - PORCH

Space Characteristics Function/adjacencies: PORCH Special Dimensions:

Ideal Plan Dimensions: 13’-8” X 37’-8” Minimum Ceiling Height: 9’-0”

Acoustics: n/a

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES

Number of Occupants: n/a

Other/Special Requirements:

C103004 IDENTIFYING DEVICES REQUIRED PUBLIC SIGNAGE

D202002 VALVES & HYDRANTS 1 FREEZE PROOF

D5020 LIGHTING AND

BRANCH WIRING GFCI RECEPTACLES, DISCONNECT SWITCH FOR

MOTORS AND HVAC EQUIPMENT

D502002 LIGHTING EQUIPMENT WALL PACK LED LIGHTS ABOVE ENTRY DOORS

AND AROUND THE BUILDING WITH PHOTOCELL

D304001 HEAT AND COOL RADIANT FLOOR. PER CALCULATIONS

D503005 SECURITY SYSTEMS CARD READERS, ALARM HORN; WEATHERPROOF

CAMERA

D509005 ELECTRIC HEATING UNDERFLOOR ELECTRIC HEATING SYSTEM AND

EQUIPMENT.

Uniformat Section

Description Qty Size Specific Requirements

3.6.1. Honor Guard - Room Requirements

B-101 – HONOR GUARD

Space Characteristics Function/adjacencies: MULTI-PURPOSE

Special Dimensions:

Ideal Plan Dimensions: 18’-3” X 30’-6” Minimum Ceiling Height: 9’-0”

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES

Number of Occupants: 3

Description Qty Size Specific Requirements

B202001 WINDOWS 7 3’-0” X 4’-6” EXTERIOR WINDOWS

C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE

C103004 IDENTIFYING DEVICES REQUIRED PUBLIC SIGNAGE

C103007 FIRE EXTINGUISHER

CABINETS

C103008 COUNTERS SOLID SURFACE COUNTER AT LAVATORIES WITH

BACK SPLASHES

C103009 CABINETS

C301003 GYPSUM WALLBOARD

FINISHES PAINTED WALL FINISH

C302004 RESILIENT FLOOR

FINISHES SVT

C302007 WALL BASE FINISHES RUBBER WALL BASE

C303001 ACOUSTICAL CEILING

TILES & PANELS ACOUSTICAL CEILING TILE

D201003 COUNTERTOP

LAVATORY 1 STANDARD STAINLESS STEEL

D201006 DRINKING FOUNTAINS

AND COOLERS 1 BI-LEVEL WITH BOTTLE FILLER

D204000 RAIN WATER

DRAINAGE 2 4” DOWNSPOUT WITH BOOT EXTERIOR OF

BUILDING

B-101 – HONOR GUARD

Space Characteristics Function/adjacencies: MULTI-PURPOSE

Special Dimensions:

Ideal Plan Dimensions: 18’-3” X 30’-6” Minimum Ceiling Height: 9’-0”

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES

Number of Occupants: 3

Description Qty Size Specific Requirements

D304001 HEAT AND COOL PER LOAD CALCULATIONS

D4010 FIRE ALARM AND

DETECTION SYSTEMS SPEAKER/STROBE; PULL STATION; FIRE ALARM

CONTROL PANEL; SMOKE DETECTOR

D5020 LIGHTING AND

BRANCH WIRING RECEPTACLES, DISCONNECT SWITCH FOR

MOTORS AND HVAC EQUIPMENT

D502002 LIGHTING EQUIPMENT

RECESSED AND UNDERCABINET LED LIGHTING;

SWITCHES; CEILING OCCUPANCY SENSORS;

EXIT SIGN

D503001 TELECOMMUNICATION

SYSTEMS PHONE AND DATA OUTLETS; CEILING WIRELESS

ACCESS POINT (WIFI)

D503005 SECURITY SYSTEM

MOTION AND GLASS BRAKE DETECTORS; CARD

READERS; SECURITY CAMERAS; SECURITY

KEYPAD

3.6.1 Honor Guard - Room Requirements

B-102 – LOCKER

Space Characteristics Function/adjacencies: LOCKER FACILITIES

Special Dimensions:

Ideal Plan Dimensions: 7’-5” X 13’-0” Minimum Ceiling Height: 9’-0”

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES

Number of Occupants: 2

Description Qty Size Specific Requirements

C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE

C102001 STANDARD INTERIOR

DOORS 1 3’0” X 7’0” SOLID CORE WOOD DOOR

C102007 INTERIOR DOOR

HARDWARE LOCKSET AND CLOSER

C103004 IDENTIFYING DEVICES REQUIRED PUBLIC/STAFF BATHROOM

SIGNAGE/PLAQUES

C103005 LOCKERS 12 LOCKERS 15” W X 18” D

C301003 GYPSUM WALLBOARD

FINISHES PAINTED WALL FINISH

C302004 RESILIENT FLOOR

FINISHES SVT

C302007 WALL BASE FINISHES RUBBER WALL BASE

C303002 GYPSUM WALLBOARD

CEILING FINISHES GYPSUM WALLBOARD CEILING

D203003 FLOOR DRAINS

D304001 HEAT AND COOL PER LOAD CALCULATIONS

D304007 BATHROOM EXHAUST PER CALCULATIONS AND VENTILATION

REQUIREMENTS

D4010 FIRE ALARM AND

DETECTION SYSTEMS SPEAKER/STROBE

B-102 – LOCKER

Function/adjacencies: LOCKER FACILITIES

Special Dimensions:

Ideal Plan Dimensions: 7’-5” X 13’-0” Minimum Ceiling Height: 9’-0”

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES

Number of Occupants: 2

Description Qty Size Specific Requirements

D5020 LIGHTING AND

BRANCH WIRING RECEPTACLES, DISCONNECT SWITCH FOR

MOTORS AND HVAC EQUIPMENT

D502002 LIGHTING EQUIPMENT RECESSED LED LIGHTING; SWITCHES; CEILING

OCCUPANCY SENSORS; EXIT SIGN

D503001 TELECOMMUNICATION

SYSTEMS CEILING WIRELESS ACCESS POINT (WIFI)

D503005 SECURITY SYSTEM MOTION DETECTOR

B-103 - STORAGE

Space Characteristics Function/adjacencies: STORAGE

Special Dimensions:

Ideal Plan Dimensions: 8’-10” X 7’-1” Minimum Ceiling Height: 9’-0”

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENIES

Number of Occupants: 1

Other/Special Requirements: 1HR PARTITION RATING, MOP BASIN, MOP HOOKS

Description Qty Size Specific Requirements

C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE

C102003 FIRE DOORS 1 3’0” X 7’0” FIRE-RATED DOOR

C102007 INTERIOR DOOR

HARDWARE LOCKSET AND CLOSER

C103004 IDENTIFYING DEVICES REQUIRED PUBLIC SIGNAGE

C103012 FIRESTOPPING

PENETRATIONS

C301003 GYPSUM WALLBOARD

FINISHES PAINTED WALL FINISH

C302004 RESILIENT FLOOR

FINISHES SVT

C302007 WALL BASE FINISHES RUBBER WALL BASE

C303001 ACOUSTICAL CEILING

TILES & PANELS ACOUSTICAL CEILING TILE

D201004 SINKS 1 MOP SINK

D304001 HEAT AND COOL PER LOAD CALCULATIONS

D4010 FIRE ALARM AND

DETECTION SYSTEMS SMOKE DETECTOR

D5020 LIGHTING AND

BRANCH WIRING RECEPTACLES

B-103 - STORAGE

Function/adjacencies: STORAGE

Special Dimensions:

Ideal Plan Dimensions: 8’-10” X 7’-1” Minimum Ceiling Height: 9’-0”

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENIES

Other/Special Requirements: 1HR PARTITION RATING, MOP BASIN, MOP HOOKS

Description Qty Size Specific Requirements

D502002 LIGHTING EQUIPMENT RECESSED LED LIGHTING; WALL OCCUPANCY

SENSORS SWITCH

B-104 - MECHANICAL

Space Characteristics Function/adjacencies: MECHANICAL Special Dimensions:

Ideal Plan Dimensions: 7’-9” X 7’-2” Minimum Ceiling Height: n/a

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES

Other/Special Requirements: 1HR PARTITION RATING

Description Qty Size Specific Requirements

C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE

C103004 IDENTIFYING DEVICES REQUIRED PUBLIC SIGNAGE

C301003 GYPSUM WALLBOARD

FINISHES PAINTED WALL FINISH

C103012 FIRESTOPPING

PENETRATIONS

C302007 WALL BASE FINISHES RUBBER WALL BASE

C302006 MASONRY & STONE

FLOORING CONCRETE FLOOR

C303090 OTHER CEILING &

CEILING FINISHES EXPOSED CEILING

D202003 DOMESTIC WATER

EQUIPMENT 1 WATER HEATERS: PROPANE FUEL TYPE

D202003 DOMESTIC WATER

EQUIPMENT BACKFLOW PREVENTERS

D202003 DOMESTIC WATER

EQUIPMENT 1 DOMESTIC HOT WATER RECIRCULATION PUMP

AND EXPANSION TANK

D202003 DOMESTIC WATER

EQUIPMENT 1 LOW PRESSURE DROP THJERMOSTATIC HOT

WATER MASTER MIXING VALVE

D209005

COMPRESSED AIR

SYSTEM (NON-

BREATHING)

1 AIR DRYER, RECEIVER TANK(S) AND OIL/WATER

SEPERATOR,

D203003 FLOOR DRAINS 1 4” FLOOR DRAIN WITH ELECTRONIC TRAP SEAL

PRIMER CONNECTION

B-104 - MECHANICAL

Function/adjacencies: MECHANICAL Special Dimensions:

Ideal Plan Dimensions: 7’-9” X 7’-2” Minimum Ceiling Height: n/a

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES

Other/Special Requirements: 1HR PARTITION RATING

Description Qty Size Specific Requirements

D204000 RAIN WATER

DRAINAGE 2 4” DOWNSPOUT WITH BOOT EXTERIOR OF

BUILDING

D304001 HEAT AND COOL PER LOAD CALCULATIONS

D4010 FIRE ALARM AND

DETECTION SYSTEMS HEAT AND SMOKE DETECTOR

D5020 LIGHTING AND

BRANCH WIRING RECEPTACLES, DISCONNECT SWITCH FOR

MOTORS AND HVAC EQUIPMENT

D502002 LIGHTING EQUIPMENT SURFACE MOUNT STRIP LED LIGHTING; TIME-

SWITCH

D503001 TELECOMMUNICATION

SYSTEMS PHONE AND DATA OUTLETS; CEILING WIRELESS

ACCESS POINT (WIFI)

D503005 SECURITY SYSTEM DOOR CONTACT

B-105 – WOMEN’S TOILET

Space Characteristics Function/adjacencies: FEMALE TOILET FACILITIES

Special Dimensions:

Ideal Plan Dimensions: 8’-10” X 7’-0” Minimum Ceiling Height: 9’-0”

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENIES

Description Qty Size Specific Requirements

C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE

C102001 STANDARD INTERIOR

DOORS 1 3’0” X 7’0” SOLID CORE WOOD DOOR

C102007 INTERIOR DOOR

HARDWARE LOCKSET AND CLOSER

C103002 TOILET & BATH

ACCESSORIES

PAPER TOWEL HOLDER WITH WASTE

RECEPTACLE

SOAP DISPENSERS AT EACH LAVATOR, WALL

MOUNTED

MIRROR AT EACH LAVATORY

C103004 IDENTIFYING DEVICES REQUIRED PUBLIC/STAFF BATHROOM

SIGNAGE/PLAQUES

C302001 TILE FLOOR FINISHES 12” X 12” CERAMIC FLOOR TILE

C301003 GYPSUM WALLBOARD

FINISHES PAINTED WALL FINISH

C302007 TILE WALL BASE

FINISHES 6” HIGH

MIN. CERAMIC TILE COVE BASE

C303002 GYPSUM WALLBOARD

CEILING FINISHES GYPSUM WALLBOARD CEILING

D201001 WATER CLOSETS 1 STANDARD FLOOR MOUNTED FLUSH VALVE

D201003 LAVATORIES 1 AUTOMATIC CONTROL

D203003 FLOOR DRAINS 1 4” FLOOR DRAIN WITH ELECTRIC TRAP SEAL

PRIMER CONNECTION.

B-105 – WOMEN’S TOILET

Function/adjacencies: FEMALE TOILET FACILITIES

Special Dimensions:

Ideal Plan Dimensions: 8’-10” X 7’-0” Minimum Ceiling Height: 9’-0”

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENIES

Description Qty Size Specific Requirements

D304001 HEAT AND COOL PER LOAD CALCULATIONS

D304007 BATHROOM EXHUAST PER CALCULATIONS AND VENTILATION

REQUIREMENTS

D4010 FIRE ALARM AND

DETECTION SYSTEMS STROBE

D5020 LIGHTING AND

BRANCH WIRING GFCI RECEPTACLES, DISCONNECT SWITCH FOR

MOTORS AND HVAC EQUIPMENT

D502002 LIGHTING EQUIPMENT RECESSED AND VANITY LED LIGHTING;

SWITCHES; CEILING OCCUPANCY SENSORS

3.6.1. Honor Guard – Room Requirements

B-106 - Men’s Toilet Space Characteristics Function/adjacencies: MALE TOILET FACILITIES

Special Dimensions:

Ideal Plan Dimensions: 7’-6” X 14’-3” Minimum Ceiling Height: 9’-0”

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES

Description Qty Size Specific Requirements

C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE

C102001 STANDARD INTERIOR

DOORS 1 3’0” X 7’0” SOLID CORE WOOD DOOR

C102007 INTERIOR DOOR

HARDWARE LOCKSET AND CLOSER

C103001

COMPARTMENTS,

CUBICLES AND TOILET

PARTITIONS

2 SOLID PHENOLIC TOILET COMPARTMENTS (1

URINAL, 1 STALL)

C103002 TOILET & BATH

ACCESSORIES

PAPER TOWEL HOLDER WITH WASTE

RECEPTACLE

SOAP DISPENSERS AT EACH LAVATOR, WALL

MOUNTED

MIRROR AT EACH LAVATORY

C103004 IDENTIFYING DEVICES REQUIRED PUBLIC/STAFF BATHROOM

SIGNAGE/PLAQUES

C302001 TILE FLOOR FINISHES 12” X 12” CERAMIC FLOOR TILE

C301003 GYPSUM WALLBOARD

FINISHES PAINTED WALL FINISH

C302007 TILE WALL BASE

FINISHES 6” HIGH

MIN. CERAMIC TILE COVE BASE

C303002 GYPSUM WALLBOARD

CEILING FINISHES GYPSUM WALLBOARD CEILING

D201001 WATER CLOSETS 1 FLOOR MOUNTED FLUSH VALVE, AUTOMATIC

CONTROL

D201002 URINALS 1 STANDARD WALL MOUNTED FLUSH VALVE, AUTOMATIC

CONTROL

B-106 - Men’s Toilet

Function/adjacencies: MALE TOILET FACILITIES

Special Dimensions:

Ideal Plan Dimensions: 7’-6” X 14’-3” Minimum Ceiling Height: 9’-0”

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES

Description Qty Size Specific Requirements

D201003 LAVATORIES 2 AUTOMATIC CONTROL

D203003 FLOOR DRAINS STANDARD FLOOR DRAIN WITH ELECTRIC TRAP SEAL

PRIMER CONNECTION

D204000 RAIN WATER

DRAINAGE 1 4” DOWNSPOUT WITH BOOT EXTERIOR OF

BUILDING

D304001 HEAT AND COOL PER LOAD CALCULATIONS

D304007 BATHROOM EXHUAST PER CALCULATIONS AND VENTILATION

REQUIREMENTS

D4010 FIRE ALARM AND

DETECTION SYSTEMS STROBE

D5020 LIGHTING AND

BRANCH WIRING GFCI RECEPTACLES, DISCONNECT SWITCH FOR

MOTORS AND HVAC EQUIPMENT

D502002 LIGHTING EQUIPMENT RECESSED AND VANITY LED LIGHTING;

SWITCHES; CEILING OCCUPANCY SENSORS

B-107 - CLOSET

Space Characteristics Function/adjacencies: CLOSET

Special Dimensions:

Ideal Plan Dimensions: 2’-0” X 7’-1” Minimum Ceiling Height: 9’-0”

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES

Description Qty Size Specific Requirements

C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE

C103004 IDENTIFYING DEVICES REQUIRED PUBLIC SIGNAGE

C301003 GYPSUM WALLBOARD

FINISHES PAINTED WALL FINISH

C302004 RESILIENT FLOOR

FINISHES SVT

C302007 WALL BASE FINISHES RUBBER WALL BASE

C303090 OTHER CEILING &

CEILING FINISHES EXPOSED CEILING

D5020 LIGHTING AND

BRANCH WIRING RECEPTACLES; PANELBOARD; SURGE

PROTECTION DEVICE; DISCONNECT SWITCH

D502002 LIGHTING EQUIPMENT SURFACE STRIP LED LIGHTING; WALL

OCCUPANCY SENSORS SWITCH

D503005 SECURITY SYSTEM CARD READER

B-108 – VAULT

Space Characteristics Function/adjacencies: GUN STORAGE VAULT

Special Dimensions:

Ideal Plan Dimensions: 2’-5” X 3’-8” Minimum Ceiling Height: 9’-0”

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENIES

Description Qty Size Specific Requirements

C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE

C103004 IDENTIFYING DEVICES REQUIRED PUBLIC SIGNAGE

C301003 GYPSUM WALLBOARD

FINISHES PAINTED WALL FINISH

C302004 RESILIENT FLOOR

FINISHES SVT

C302007 WALL BASE FINISHES RUBBER WALL BASE

C303090 OTHER CEILING &

CEILING FINISHES CONCRETE CEILING

D304001 HEAT AND COOL PER LOAD CALCULATIONS

D502002 LIGHTING EQUIPMENT SURFACE STRIP LED LIGHTING; WALL

OCCUPANCY SENSORS SWITCH

D503001 TELECOMMUNICATION

SYSTEMS TELECOM ENCLOSURE CABINET; UPS; PATCH

PANELS; PDUS

D503005 SECURITY SYSTEM NVR; CARD READERS; SECURITY CAMERAS

(OUTSIDE)

B-109 – PASSAGE

Space Characteristics Function/adjacencies: PASSAGE

Special Dimensions:

Ideal Plan Dimensions: 6’-1” X 9’-7” Minimum Ceiling Height: 9’-0”

Acoustics: STC 45

Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENIES

Description Qty Size Specific Requirements

C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE

C103004 IDENTIFYING DEVICES REQUIRED PUBLIC SIGNAGE

C301003 GYPSUM WALLBOARD

FINISHES PAINTED WALL FINISH

C302004 RESILIENT FLOOR

FINISHES SVT

C302007 WALL BASE FINISHES RUBBER WALL BASE

C303001 ACOUSTICAL CEILING

TILES & PANELS ACOUSTICAL CEILING TILE

D304001 HEAT AND COOL PER LOAD CALCULATIONS

D5020 LIGHTING AND

BRANCH WIRING RECEPTACLE

D502002 LIGHTING EQUIPMENT RECESSED LED LIGHTING; CEILING OCCUPANCY

SENSORS

3.6.1 Honor Guard Room Data flysheet
B-100_PORCH_ROOM REQUIREMENTS
Uniformat Section
B-101_HONOR GUARD_ROOM REQUIREMENTS
Uniformat Section
B-102_LOCKER ROOM_ROOM REQUIREMENTS
Uniformat Section
B-103_STORAGE_ROOM REQUIREMENTS
Uniformat Section
B-104_MECHANICAL_ROOM REQUIREMENTS
Uniformat Section
B-105_WOMENS TOILET ROOM_ROOM REQUIREMENTS
Uniformat Section
B-106_MENS TOILET ROOM_ROOM REQUIREMENTS
Uniformat Section
B-107_CLOSET_ROOM REQUIREMENTS
Uniformat Section
B-108_VAULT_ROOM REQUIREMENTS
Uniformat Section
B-109_PASSAGE_ROOM REQUIREMENTS
Uniformat Section