Attachment 4_3.6.1 Honor Guard Room Data Sheets.pdf
PDF 295 KB Posted
- Attached to
- Y1EB--Major Construction Project Western New York National Cemetery - Phase 1C Pembroke, NY
- Solicitation number
- 36C10F23R0012
About this file
This document package includes room data sheets and specifications for the proposed Honor Guard Building at the Western New York National Cemetery in Pembroke, New York. The solicitation is for a major construction project to build Phase 1C of the cemetery maintenance complex. The Department of Veterans Affairs Office of Construction and Facilities Management is the contracting agency.
The room data sheets provide requirements for 11 spaces within the Honor Guard Building, including dimensions, functions, finishes, fixtures, equipment, and technical specifications. Spaces outlined include an honor guard room, locker room, storage, mechanical room, men's and women's toilets, closet, vault, and passage areas. Mechanical, electrical, plumbing, fire protection, security and telecommunications specifications are identified by Uniformat section for each room.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Western New York National Cemetery Phase 1C Maintenance Complex Design Build RFP 936-002C Pembroke, NY 3.6.1 Honor Guard Building
PART 3 - CHAPTER 6 - Page 1
3.6.1 Honor Guard Building- Room Requirements
3.6.1 Honor Guard - Room Requirements
B-100 - PORCH
Space Characteristics Function/adjacencies: PORCH Special Dimensions:
Ideal Plan Dimensions: 13’-8” X 37’-8” Minimum Ceiling Height: 9’-0”
Acoustics: n/a
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES
Number of Occupants: n/a
Other/Special Requirements:
C103004 IDENTIFYING DEVICES REQUIRED PUBLIC SIGNAGE
D202002 VALVES & HYDRANTS 1 FREEZE PROOF
D5020 LIGHTING AND
BRANCH WIRING GFCI RECEPTACLES, DISCONNECT SWITCH FOR
MOTORS AND HVAC EQUIPMENT
D502002 LIGHTING EQUIPMENT WALL PACK LED LIGHTS ABOVE ENTRY DOORS
AND AROUND THE BUILDING WITH PHOTOCELL
D304001 HEAT AND COOL RADIANT FLOOR. PER CALCULATIONS
D503005 SECURITY SYSTEMS CARD READERS, ALARM HORN; WEATHERPROOF
CAMERA
D509005 ELECTRIC HEATING UNDERFLOOR ELECTRIC HEATING SYSTEM AND
EQUIPMENT.
Uniformat Section
Description Qty Size Specific Requirements
3.6.1. Honor Guard - Room Requirements
B-101 – HONOR GUARD
Space Characteristics Function/adjacencies: MULTI-PURPOSE
Special Dimensions:
Ideal Plan Dimensions: 18’-3” X 30’-6” Minimum Ceiling Height: 9’-0”
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES
Number of Occupants: 3
Description Qty Size Specific Requirements
B202001 WINDOWS 7 3’-0” X 4’-6” EXTERIOR WINDOWS
C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE
C103004 IDENTIFYING DEVICES REQUIRED PUBLIC SIGNAGE
C103007 FIRE EXTINGUISHER
CABINETS
C103008 COUNTERS SOLID SURFACE COUNTER AT LAVATORIES WITH
BACK SPLASHES
C103009 CABINETS
C301003 GYPSUM WALLBOARD
FINISHES PAINTED WALL FINISH
C302004 RESILIENT FLOOR
FINISHES SVT
C302007 WALL BASE FINISHES RUBBER WALL BASE
C303001 ACOUSTICAL CEILING
TILES & PANELS ACOUSTICAL CEILING TILE
D201003 COUNTERTOP
LAVATORY 1 STANDARD STAINLESS STEEL
D201006 DRINKING FOUNTAINS
AND COOLERS 1 BI-LEVEL WITH BOTTLE FILLER
D204000 RAIN WATER
DRAINAGE 2 4” DOWNSPOUT WITH BOOT EXTERIOR OF
BUILDING
B-101 – HONOR GUARD
Space Characteristics Function/adjacencies: MULTI-PURPOSE
Special Dimensions:
Ideal Plan Dimensions: 18’-3” X 30’-6” Minimum Ceiling Height: 9’-0”
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES
Number of Occupants: 3
Description Qty Size Specific Requirements
D304001 HEAT AND COOL PER LOAD CALCULATIONS
D4010 FIRE ALARM AND
DETECTION SYSTEMS SPEAKER/STROBE; PULL STATION; FIRE ALARM
CONTROL PANEL; SMOKE DETECTOR
D5020 LIGHTING AND
BRANCH WIRING RECEPTACLES, DISCONNECT SWITCH FOR
MOTORS AND HVAC EQUIPMENT
D502002 LIGHTING EQUIPMENT
RECESSED AND UNDERCABINET LED LIGHTING;
SWITCHES; CEILING OCCUPANCY SENSORS;
EXIT SIGN
D503001 TELECOMMUNICATION
SYSTEMS PHONE AND DATA OUTLETS; CEILING WIRELESS
ACCESS POINT (WIFI)
D503005 SECURITY SYSTEM
MOTION AND GLASS BRAKE DETECTORS; CARD
READERS; SECURITY CAMERAS; SECURITY
KEYPAD
3.6.1 Honor Guard - Room Requirements
B-102 – LOCKER
Space Characteristics Function/adjacencies: LOCKER FACILITIES
Special Dimensions:
Ideal Plan Dimensions: 7’-5” X 13’-0” Minimum Ceiling Height: 9’-0”
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES
Number of Occupants: 2
Description Qty Size Specific Requirements
C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE
C102001 STANDARD INTERIOR
DOORS 1 3’0” X 7’0” SOLID CORE WOOD DOOR
C102007 INTERIOR DOOR
HARDWARE LOCKSET AND CLOSER
C103004 IDENTIFYING DEVICES REQUIRED PUBLIC/STAFF BATHROOM
SIGNAGE/PLAQUES
C103005 LOCKERS 12 LOCKERS 15” W X 18” D
C301003 GYPSUM WALLBOARD
FINISHES PAINTED WALL FINISH
C302004 RESILIENT FLOOR
FINISHES SVT
C302007 WALL BASE FINISHES RUBBER WALL BASE
C303002 GYPSUM WALLBOARD
CEILING FINISHES GYPSUM WALLBOARD CEILING
D203003 FLOOR DRAINS
D304001 HEAT AND COOL PER LOAD CALCULATIONS
D304007 BATHROOM EXHAUST PER CALCULATIONS AND VENTILATION
REQUIREMENTS
D4010 FIRE ALARM AND
DETECTION SYSTEMS SPEAKER/STROBE
B-102 – LOCKER
Function/adjacencies: LOCKER FACILITIES
Special Dimensions:
Ideal Plan Dimensions: 7’-5” X 13’-0” Minimum Ceiling Height: 9’-0”
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES
Number of Occupants: 2
Description Qty Size Specific Requirements
D5020 LIGHTING AND
BRANCH WIRING RECEPTACLES, DISCONNECT SWITCH FOR
MOTORS AND HVAC EQUIPMENT
D502002 LIGHTING EQUIPMENT RECESSED LED LIGHTING; SWITCHES; CEILING
OCCUPANCY SENSORS; EXIT SIGN
D503001 TELECOMMUNICATION
SYSTEMS CEILING WIRELESS ACCESS POINT (WIFI)
D503005 SECURITY SYSTEM MOTION DETECTOR
B-103 - STORAGE
Space Characteristics Function/adjacencies: STORAGE
Special Dimensions:
Ideal Plan Dimensions: 8’-10” X 7’-1” Minimum Ceiling Height: 9’-0”
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENIES
Number of Occupants: 1
Other/Special Requirements: 1HR PARTITION RATING, MOP BASIN, MOP HOOKS
Description Qty Size Specific Requirements
C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE
C102003 FIRE DOORS 1 3’0” X 7’0” FIRE-RATED DOOR
C102007 INTERIOR DOOR
HARDWARE LOCKSET AND CLOSER
C103004 IDENTIFYING DEVICES REQUIRED PUBLIC SIGNAGE
C103012 FIRESTOPPING
PENETRATIONS
C301003 GYPSUM WALLBOARD
FINISHES PAINTED WALL FINISH
C302004 RESILIENT FLOOR
FINISHES SVT
C302007 WALL BASE FINISHES RUBBER WALL BASE
C303001 ACOUSTICAL CEILING
TILES & PANELS ACOUSTICAL CEILING TILE
D201004 SINKS 1 MOP SINK
D304001 HEAT AND COOL PER LOAD CALCULATIONS
D4010 FIRE ALARM AND
DETECTION SYSTEMS SMOKE DETECTOR
D5020 LIGHTING AND
BRANCH WIRING RECEPTACLES
B-103 - STORAGE
Function/adjacencies: STORAGE
Special Dimensions:
Ideal Plan Dimensions: 8’-10” X 7’-1” Minimum Ceiling Height: 9’-0”
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENIES
Other/Special Requirements: 1HR PARTITION RATING, MOP BASIN, MOP HOOKS
Description Qty Size Specific Requirements
D502002 LIGHTING EQUIPMENT RECESSED LED LIGHTING; WALL OCCUPANCY
SENSORS SWITCH
B-104 - MECHANICAL
Space Characteristics Function/adjacencies: MECHANICAL Special Dimensions:
Ideal Plan Dimensions: 7’-9” X 7’-2” Minimum Ceiling Height: n/a
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES
Other/Special Requirements: 1HR PARTITION RATING
Description Qty Size Specific Requirements
C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE
C103004 IDENTIFYING DEVICES REQUIRED PUBLIC SIGNAGE
C301003 GYPSUM WALLBOARD
FINISHES PAINTED WALL FINISH
C103012 FIRESTOPPING
PENETRATIONS
C302007 WALL BASE FINISHES RUBBER WALL BASE
C302006 MASONRY & STONE
FLOORING CONCRETE FLOOR
C303090 OTHER CEILING &
CEILING FINISHES EXPOSED CEILING
D202003 DOMESTIC WATER
EQUIPMENT 1 WATER HEATERS: PROPANE FUEL TYPE
D202003 DOMESTIC WATER
EQUIPMENT BACKFLOW PREVENTERS
D202003 DOMESTIC WATER
EQUIPMENT 1 DOMESTIC HOT WATER RECIRCULATION PUMP
AND EXPANSION TANK
D202003 DOMESTIC WATER
EQUIPMENT 1 LOW PRESSURE DROP THJERMOSTATIC HOT
WATER MASTER MIXING VALVE
D209005
COMPRESSED AIR
SYSTEM (NON-
BREATHING)
1 AIR DRYER, RECEIVER TANK(S) AND OIL/WATER
SEPERATOR,
D203003 FLOOR DRAINS 1 4” FLOOR DRAIN WITH ELECTRONIC TRAP SEAL
PRIMER CONNECTION
B-104 - MECHANICAL
Function/adjacencies: MECHANICAL Special Dimensions:
Ideal Plan Dimensions: 7’-9” X 7’-2” Minimum Ceiling Height: n/a
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES
Other/Special Requirements: 1HR PARTITION RATING
Description Qty Size Specific Requirements
D204000 RAIN WATER
DRAINAGE 2 4” DOWNSPOUT WITH BOOT EXTERIOR OF
BUILDING
D304001 HEAT AND COOL PER LOAD CALCULATIONS
D4010 FIRE ALARM AND
DETECTION SYSTEMS HEAT AND SMOKE DETECTOR
D5020 LIGHTING AND
BRANCH WIRING RECEPTACLES, DISCONNECT SWITCH FOR
MOTORS AND HVAC EQUIPMENT
D502002 LIGHTING EQUIPMENT SURFACE MOUNT STRIP LED LIGHTING; TIME-
SWITCH
D503001 TELECOMMUNICATION
SYSTEMS PHONE AND DATA OUTLETS; CEILING WIRELESS
ACCESS POINT (WIFI)
D503005 SECURITY SYSTEM DOOR CONTACT
B-105 – WOMEN’S TOILET
Space Characteristics Function/adjacencies: FEMALE TOILET FACILITIES
Special Dimensions:
Ideal Plan Dimensions: 8’-10” X 7’-0” Minimum Ceiling Height: 9’-0”
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENIES
Description Qty Size Specific Requirements
C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE
C102001 STANDARD INTERIOR
DOORS 1 3’0” X 7’0” SOLID CORE WOOD DOOR
C102007 INTERIOR DOOR
HARDWARE LOCKSET AND CLOSER
C103002 TOILET & BATH
ACCESSORIES
PAPER TOWEL HOLDER WITH WASTE
RECEPTACLE
SOAP DISPENSERS AT EACH LAVATOR, WALL
MOUNTED
MIRROR AT EACH LAVATORY
C103004 IDENTIFYING DEVICES REQUIRED PUBLIC/STAFF BATHROOM
SIGNAGE/PLAQUES
C302001 TILE FLOOR FINISHES 12” X 12” CERAMIC FLOOR TILE
C301003 GYPSUM WALLBOARD
FINISHES PAINTED WALL FINISH
C302007 TILE WALL BASE
FINISHES 6” HIGH
MIN. CERAMIC TILE COVE BASE
C303002 GYPSUM WALLBOARD
CEILING FINISHES GYPSUM WALLBOARD CEILING
D201001 WATER CLOSETS 1 STANDARD FLOOR MOUNTED FLUSH VALVE
D201003 LAVATORIES 1 AUTOMATIC CONTROL
D203003 FLOOR DRAINS 1 4” FLOOR DRAIN WITH ELECTRIC TRAP SEAL
PRIMER CONNECTION.
B-105 – WOMEN’S TOILET
Function/adjacencies: FEMALE TOILET FACILITIES
Special Dimensions:
Ideal Plan Dimensions: 8’-10” X 7’-0” Minimum Ceiling Height: 9’-0”
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENIES
Description Qty Size Specific Requirements
D304001 HEAT AND COOL PER LOAD CALCULATIONS
D304007 BATHROOM EXHUAST PER CALCULATIONS AND VENTILATION
REQUIREMENTS
D4010 FIRE ALARM AND
DETECTION SYSTEMS STROBE
D5020 LIGHTING AND
BRANCH WIRING GFCI RECEPTACLES, DISCONNECT SWITCH FOR
MOTORS AND HVAC EQUIPMENT
D502002 LIGHTING EQUIPMENT RECESSED AND VANITY LED LIGHTING;
SWITCHES; CEILING OCCUPANCY SENSORS
3.6.1. Honor Guard – Room Requirements
B-106 - Men’s Toilet Space Characteristics Function/adjacencies: MALE TOILET FACILITIES
Special Dimensions:
Ideal Plan Dimensions: 7’-6” X 14’-3” Minimum Ceiling Height: 9’-0”
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES
Description Qty Size Specific Requirements
C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE
C102001 STANDARD INTERIOR
DOORS 1 3’0” X 7’0” SOLID CORE WOOD DOOR
C102007 INTERIOR DOOR
HARDWARE LOCKSET AND CLOSER
C103001
COMPARTMENTS,
CUBICLES AND TOILET
PARTITIONS
2 SOLID PHENOLIC TOILET COMPARTMENTS (1
URINAL, 1 STALL)
C103002 TOILET & BATH
ACCESSORIES
PAPER TOWEL HOLDER WITH WASTE
RECEPTACLE
SOAP DISPENSERS AT EACH LAVATOR, WALL
MOUNTED
MIRROR AT EACH LAVATORY
C103004 IDENTIFYING DEVICES REQUIRED PUBLIC/STAFF BATHROOM
SIGNAGE/PLAQUES
C302001 TILE FLOOR FINISHES 12” X 12” CERAMIC FLOOR TILE
C301003 GYPSUM WALLBOARD
FINISHES PAINTED WALL FINISH
C302007 TILE WALL BASE
FINISHES 6” HIGH
MIN. CERAMIC TILE COVE BASE
C303002 GYPSUM WALLBOARD
CEILING FINISHES GYPSUM WALLBOARD CEILING
D201001 WATER CLOSETS 1 FLOOR MOUNTED FLUSH VALVE, AUTOMATIC
CONTROL
D201002 URINALS 1 STANDARD WALL MOUNTED FLUSH VALVE, AUTOMATIC
CONTROL
B-106 - Men’s Toilet
Function/adjacencies: MALE TOILET FACILITIES
Special Dimensions:
Ideal Plan Dimensions: 7’-6” X 14’-3” Minimum Ceiling Height: 9’-0”
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES
Description Qty Size Specific Requirements
D201003 LAVATORIES 2 AUTOMATIC CONTROL
D203003 FLOOR DRAINS STANDARD FLOOR DRAIN WITH ELECTRIC TRAP SEAL
PRIMER CONNECTION
D204000 RAIN WATER
DRAINAGE 1 4” DOWNSPOUT WITH BOOT EXTERIOR OF
BUILDING
D304001 HEAT AND COOL PER LOAD CALCULATIONS
D304007 BATHROOM EXHUAST PER CALCULATIONS AND VENTILATION
REQUIREMENTS
D4010 FIRE ALARM AND
DETECTION SYSTEMS STROBE
D5020 LIGHTING AND
BRANCH WIRING GFCI RECEPTACLES, DISCONNECT SWITCH FOR
MOTORS AND HVAC EQUIPMENT
D502002 LIGHTING EQUIPMENT RECESSED AND VANITY LED LIGHTING;
SWITCHES; CEILING OCCUPANCY SENSORS
B-107 - CLOSET
Space Characteristics Function/adjacencies: CLOSET
Special Dimensions:
Ideal Plan Dimensions: 2’-0” X 7’-1” Minimum Ceiling Height: 9’-0”
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENCIES
Description Qty Size Specific Requirements
C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE
C103004 IDENTIFYING DEVICES REQUIRED PUBLIC SIGNAGE
C301003 GYPSUM WALLBOARD
FINISHES PAINTED WALL FINISH
C302004 RESILIENT FLOOR
FINISHES SVT
C302007 WALL BASE FINISHES RUBBER WALL BASE
C303090 OTHER CEILING &
CEILING FINISHES EXPOSED CEILING
D5020 LIGHTING AND
BRANCH WIRING RECEPTACLES; PANELBOARD; SURGE
PROTECTION DEVICE; DISCONNECT SWITCH
D502002 LIGHTING EQUIPMENT SURFACE STRIP LED LIGHTING; WALL
OCCUPANCY SENSORS SWITCH
D503005 SECURITY SYSTEM CARD READER
B-108 – VAULT
Space Characteristics Function/adjacencies: GUN STORAGE VAULT
Special Dimensions:
Ideal Plan Dimensions: 2’-5” X 3’-8” Minimum Ceiling Height: 9’-0”
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENIES
Description Qty Size Specific Requirements
C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE
C103004 IDENTIFYING DEVICES REQUIRED PUBLIC SIGNAGE
C301003 GYPSUM WALLBOARD
FINISHES PAINTED WALL FINISH
C302004 RESILIENT FLOOR
FINISHES SVT
C302007 WALL BASE FINISHES RUBBER WALL BASE
C303090 OTHER CEILING &
CEILING FINISHES CONCRETE CEILING
D304001 HEAT AND COOL PER LOAD CALCULATIONS
D502002 LIGHTING EQUIPMENT SURFACE STRIP LED LIGHTING; WALL
OCCUPANCY SENSORS SWITCH
D503001 TELECOMMUNICATION
SYSTEMS TELECOM ENCLOSURE CABINET; UPS; PATCH
PANELS; PDUS
D503005 SECURITY SYSTEM NVR; CARD READERS; SECURITY CAMERAS
(OUTSIDE)
B-109 – PASSAGE
Space Characteristics Function/adjacencies: PASSAGE
Special Dimensions:
Ideal Plan Dimensions: 6’-1” X 9’-7” Minimum Ceiling Height: 9’-0”
Acoustics: STC 45
Access: SEE ARCHITECTURAL PLAN DIAGRAM FOR PREFERRED ACCESS/ADJACENIES
Description Qty Size Specific Requirements
C101001 FIXED PARTITIONS FROM FLOOR TO UNDERSIDE OF STRUCTURE
C103004 IDENTIFYING DEVICES REQUIRED PUBLIC SIGNAGE
C301003 GYPSUM WALLBOARD
FINISHES PAINTED WALL FINISH
C302004 RESILIENT FLOOR
FINISHES SVT
C302007 WALL BASE FINISHES RUBBER WALL BASE
C303001 ACOUSTICAL CEILING
TILES & PANELS ACOUSTICAL CEILING TILE
D304001 HEAT AND COOL PER LOAD CALCULATIONS
D5020 LIGHTING AND
BRANCH WIRING RECEPTACLE
D502002 LIGHTING EQUIPMENT RECESSED LED LIGHTING; CEILING OCCUPANCY
SENSORS
| 3.6.1 Honor Guard Room Data flysheet |
| B-100_PORCH_ROOM REQUIREMENTS |
| Uniformat Section |
| B-101_HONOR GUARD_ROOM REQUIREMENTS |
| Uniformat Section |
| B-102_LOCKER ROOM_ROOM REQUIREMENTS |
| Uniformat Section |
| B-103_STORAGE_ROOM REQUIREMENTS |
| Uniformat Section |
| B-104_MECHANICAL_ROOM REQUIREMENTS |
| Uniformat Section |
| B-105_WOMENS TOILET ROOM_ROOM REQUIREMENTS |
| Uniformat Section |
| B-106_MENS TOILET ROOM_ROOM REQUIREMENTS |
| Uniformat Section |
| B-107_CLOSET_ROOM REQUIREMENTS |
| Uniformat Section |
| B-108_VAULT_ROOM REQUIREMENTS |
| Uniformat Section |
| B-109_PASSAGE_ROOM REQUIREMENTS |
| Uniformat Section |
File details come from the government source that posted it. Updated .