ATTACHMENT 36 C - SARGENT 10X Line Catalog.pdf
PDF 1 MB Posted
- Solicitation number
- 36C24826R0090
About this file
This is a product catalog for the SARGENT 10X Line Cylindrical Lever Lock system manufactured by Sargent Manufacturing Company, an ASSA ABLOY Group company. The 10X Line is engineered for high-traffic, high-abuse commercial and institutional applications including offices, schools, hospitals, manufacturing facilities, and government buildings.
The 10X Line exceeds ANSI/BHMA Grade 1 performance standards by up to 20 times, featuring solid cast zinc levers with decorative design options, anti-rotational through-bolts, stainless steel 1/2-inch throw latches, and a 3-1/2-inch rose scalp design. The catalog provides comprehensive specifications including door prep requirements (1-3/4 to 2-1/4 inches thick), multiple backset options (2-3/8 to 5 inches), 26 different mechanical functions ranging from basic passage locks to complex electromechanical systems, and 14 finish options including MicroShield antimicrobial coating. The locks support various cylinder formats including conventional brass cylinders, interchangeable cores (SFIC and LFIC), and high-security options (Degree®, Signature, Keso, XC). Mechanical options include adapter plates for thin doors, 3/4-inch throw latches for fire-rated applications, security fasteners, and tactile warning features for ADA compliance. The system includes electromechanical functions with fail-safe and fail-secure options requiring 12VDC or 24VDC power supplies. All locks are UL/cUL listed for 3-hour fire-rated doors up to 4 feet by 10 feet and comply with windstorm/hurricane certifications including Florida Building Code FL2998 standards. The catalog includes suggested architectural specifications, detailed ordering instructions with handing options, and information on strikes, latches, and miscellaneous replacement parts.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Product Catalog
10X Line Cylindrical Lever Lock
1-800-727-5477 • www.sargentlock.com2
10X Line Cylindrical Lever Locks
/2
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Table of Contents
Overview
Certifications
Technical Details
Lever & Rose Designs
Functions.....................................................................................................................................................................................................7-9
Electromechanical Functions & Accessories
Cylinders
Latches
Strikes and Miscellaneous Parts
Cylinder Options....................................................................................................................................................................................14-15
Mechanical Options
Finishes, Packaging
How to Order
Architectural Specifications
MicroShield® Coating
• � Revolutionary finish coating available on all SARGENT product lines, utilizes a silver-based antimicrobial compound from Agion Technologies
• � As an integral part of the finish coating, MicroShield lasts for the life of the hardware
• � MicroShield coating permanently suppresses the growth of bacteria, algae, fungus, mold and mildew. It is effective against a broad spectrum of bacteria.
• � Non-toxic and completely safe. The Agion antimicrobial compound is EPA and NSF approved and FDA listed for use in medical and food preparation equipment.
• � Applications: Anywhere there is need for a clean environment (hospitals, laboratories, schools, medical centers, daycare, food processing etc.)
MicroShield®
ASSA ABLOY Group companies offer MicroShield®, an anti-microbial coating for door hardware. MicroShield uses proven silver ion-based technology from Agion®, a leading provider of antimicrobial solutions, to stem the spread of bacteria and other microbes.
MicroShield® is a trademark of ASSA ABLOY Access and Egress Hardware Group, Inc.
The Agion antimicrobial is not intended as a substitute for good hygiene. Coated products must still be cleaned to ensure the surfaces will be free of destructive microbes.
ASSA ABLOY makes no representations or warranties, express or implied, as to the efficacy of the Agion antimicrobial. A copy of the Agion warranty is available upon request.
Agion is a registered trademark of Agion Technologies, Inc., Wakefield, MA, USA.
On The Cover
• 10XG05 x LL Entrance Function
1-800-727-5477 • www.sargentlock.com 3
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Overview
The SARGENT 10X Line is engineered to secure and protect high-traffic, high-abuse spaces. It doesn’t simply meet ANSI/BHMA Grade 1 performance standards for durability, strength and performance, it exceeds them - by as much as 20 times. That means occupants enjoy consistent performance for the life of the product.
Solid, cast levers with decorative design options
Anti-rotational through-bolts at 6 and 12 o’clock positions
Push/turn button design withstands excessive abuse against door stops or walls
3-1/2" (89mm) Rose scalp design
Stainless Steel 1/2" (13mm) throw latch
Applications
| • | Heavy duty commercial and institutional interior and exterior doors |
| • | Offices |
| • | Schools/Universities |
| • | Hospitals |
| • | Manufacturing facilities |
| • | Government |
1-800-727-5477 • www.sargentlock.com4
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Certifications
Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Sargent Manufacturing Company makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.
ANSI/BHMA Certified ANSI/BHMA A156.2 (2017) Series 4000 — Grade 1 Certified ANSI/BHMA A156.41
UL/cUL UL/cUL listed to US and Canadian safety standards for 3 hour doors up to 4' x 10' (double doors require 41- option)
NFPA 80 Conforms for life safety and property protection, Standard for Fire Doors and Other Opening Protectives
Positive Pressure Meets ANSI/UL 10C, Positive Pressure Fire Test of Door Assemblies
ADA All levers conform to ADA clear opening width requirements of ANSI A117.1
California State Reference Code (Formerly Title 19, California State Fire Marshal Standard)
All levers with returns comply; levers return to within 1/2" (13mm) of door face
Windstorm/Hurricane All individual components of a total door opening are required to comply with each code.
Florida Building Code: FL2998 UL Certification Directory: ZHEM.R21744 – Latching Hardware
UL Certification Directory: ZHLL.R21744 – Products for Use in Windstorm-rated Assemblies
ANSI/SDI A250.13 (2014) “Testing and Rating of Severe Windstorm Resistant Components for Swinging Door Assemblies”
ASTM E330 (2002) “Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference”*
ASTM E1886 (2005) “Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials”*
ASTM E1996 (2009) “Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes”*
(TAS) 201 (1994) “Impact Test Procedures”*
(TAS) 202 (1994) “Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference”*
(TAS) 203 (1994) “Criteria for Testing Products Subject to Cyclic Wind Pressure Loading”*
ASTM E330 (2002) "Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference"
ASTM E1886 (2005) "Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials"
ASTM E1996 (2009) "Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes"
SARGENT Manufacturing’s products meet building codes that require hurricane and windstorm certifications, including some of the most stringent building codes as specified in the Florida Building Code, Miami Dade Code and the International Building Code. Listed below are certifications and standards met by the 10X Line lock.
Certifications to meet assembly requirements are done in conjunction with doors from ASSA ABLOY Group companies CECO DOOR and CURRIES.
Windstorm Certifications: Florida Building Codes & UL Listings
* Published in the 7th Edition (2020), “Florida Building Code” (FBC), State Product Approval Number FL2998
Certification/Compliance
1-800-727-5477 • www.sargentlock.com 5
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Technical Details
Door Prep ANSI/BHMA A156.115
Door Thickness �1-3/4" (44mm) thick door adjusts to 2" (51mm) standard 1-3/8" (35mm) thick door, specify 1- Option for Adapter plates Over 2" (51mm) up to 2-1/4" (57mm), specify 31- Option
Minimum Stile 4-1/2" (114mm)
Handing Non-handed
Backset
2-3/4" (70mm) backset w/ 1-1/8" front (standard) 2-3/8" (60mm) backset w/ 1" wide front (specify 20- Option) 3-3/4" (95mm) backset w/ 1-1/8" front (specify 23- Option) 5" (127mm) backset w/ 1-1/8" front (specify 25- Option)
Latchbolt Stainless steel, 1/2" (13mm) throw Optional: Brass 3/4" (19mm) throw deadlocking fire latch for pair of doors (specify 41- Option)
Front Wrought brass and stainless steel 2-1/4" (57mm) x 1-1/8" (29mm) Fixed Bevel 2-1/4" (57mm) x 1" (25mm) (included with 20- Option)
Strike
Wrought brass, bronze and stainless steel 808 curved lip ANSI strike - standard 800 curved lip strike (specify 29- Option) Wrought box strike available (specify WBS- Option)
Cylinder Brass, 6-pin LA keyway, 1-bitted standard, specify KD for keyed different/random
Keys Two nickel silver change keys per lock standard
Masterkeying Can be master keyed or grand master keyed Construction key systems available
Lead Lining Lead provided between lockbody and spring cartridge (specify 74- Option)
Tactile Levers Knurling (etching) or abrasive coating (applied finish) applied to backside of levers (see Options page 16)
Finishes See page 17
Warranty Ten-year limited
• Exceeds 3,100 in-lb abusive locked lever torque with no entry while maintaining egress (2.6 times ANSI/BHMA A156.2 requirements)
• Exceeds 1,600 lbs offset lever pull with no entry for protection against attacks (8 times ANSI/BHMA A156.2 requirements)
• Latch retraction with 100lb preload (2 times ANSI/BHMA A156.2) while maintaining ANSI/BHMA requirements for operation in warped doors
• No access with minimum 100 vertical impacts for protection against vandalism attempts (20 times ANSI/BHMA A156.2 requirements)
• Independent return springs allow lock to exceed ANSI/BHMA A156.2 Grade 1 cycle requirements without lever sag
• Innovative push/turn button design to withstand excessive abuse against door stops or walls.
• Lock chassis design supports all cylinder formats allowing flexibility for from fixed core to interchangeable core cylinders.
• High Security and security key systems available (Degree®, Signature, Keso, XC)
• Patent pending adjustable push/turn button for easy door thickness adjustment.
• Rigid lever standard; freewheeling levers available for vandal resistance.
| • | Available with 26 mechanical functions |
| • | 14 finishes and Microshield options |
| • | Multilple lever options including |
decorative designs
Strength & Durability Flexibility Broad Offering
1-800-727-5477 • www.sargentlock.com6
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Lever & Rose Designs
P*
L*
Any rose or lever on this page can be combined to suit individual taste.
All lever height measurements represent total distance from door face. Dimensions shown using L rose.
*Lever with return to within 1/2" of door face.
Levers - Solid Cast Zinc
B
L
Roses - Wrought Brass or Bronze
G
Decorative Levers
MD
ND*
MB
MW*
4-9/16" (116mm)
2-15/16" (75mm)
5/8" (16mm)
3-1/2" (89mm)
3/8" (10mm)
3-1/2" (89mm)
5/8" (16mm)
4-1/2" (114mm)
2-15/16" (75mm)
5/8" (16mm)
5-1/16" (129mm)
2-15/16" (75mm)
5/8" (16mm)
4-5/8" (117mm)
2-15/16" (75mm)
5/8" (16mm)
4-5/8" (117mm)
2-15/16" (75mm)
5/8" (16mm)
4-9/16" (116mm)
2-15/16" (75mm)
5/8" (16mm)
4-9/16" (116mm)
2-15/16" (75mm)
5/8" (16mm)
1-800-727-5477 • www.sargentlock.com 7
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Functions
• Deadlocking latch
• Latch by lever inside or key outside
• Outside lever rigid at all times
• ANSI/BHMA F86
04 Storeroom or Closet
10XG04
• Deadlocking latch
| • | Latch by either lever unless outside lever is |
| locked by push/turn button in inside lever |
• � Push button released by key outside or lever inside
• Turn button must be released manually
• Key retracts latch when outside lever is locked
• ANSI/BHMA F109
05 Entrance or Office
10XG05
• Deadlocking latch
| • | Latch by either lever unless outside lever is |
| locked by push button in inside lever |
• Push button released by key or turning inside lever
• � Closing door does not unlock outside lever or release button
• � Key in outside lever retracts latch when outside lever is locked and releases inside push button
• ANSI/BHMA F82A
24 Entrance or Office
10XG24
• Deadlocking latch
| • | Latch by either lever unless outside lever is |
| locked by key |
| • | Key in outside lever locks or unlocks outside |
| lever and retracts latch |
• Inside lever always operative
• ANSI/BHMA F84
37 Classroom
10XG37
Single Cylinder Functions
• Deadlocking latch
• �Latch by key outside and lever inside
• Outside lever always rigid
• � Depressing push button when door is closed shuts out all keys except emergency key and projects visual occupancy indicator in cylinder face
• � Push button released by turning inside lever automatically reactivating all keys and retracting visual occupancy indicator
• � Lock out key fixes push button in locked position, shutting out all keys except emergency
| • | Push button fixed by lockout key must be |
| released manually |
• Lock out key provided
• See option page for restrictions to 50 function
• � Emergency key ordered separately. Part # 6267EMK plus key system registry number
• ANSI/BHMA F93
50 Hotel, Dormitory or Apartment
10XG50
• Deadlocking latch
• � Latch by either lever unless outside lever is locked by push button in inside lever
• �Key retracts latch when outside lever is locked
• �Push button released by turning inside lever, closing door, or by key in outside lever unless push button is fixed in locked position by turning coin slot in inside lever
• Slotted inside button must be manually released
• ANSI/BHMA F92
44 Service Station
10XG44
Shaded lever indicates it is rigid at all times.
Freewheeling locking levers available on all locking functions, specify FW- Option.
• Deadlocking latch
• Latch by key
• Lever rigid at all times
• Lever on one side; blank plate on other side
• ANSI/BHMA F112
07 Communicating Storeroom
10XG07
• Deadlocking latch
• Latch by lever unless lever is locked by key
• Key in lever locks or unlocks lever and retracts latch
• Lever on one side; blank plate on other side
• ANSI/BHMA F113
08 Communicating Classroom
10XG08
1-800-727-5477 • www.sargentlock.com8
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Double Cylinder Functions
• Deadlocking latch
| • | Latch by either lever unless outside lever is |
| locked by key in inside lever |
| • | Key in outside lever retracts latch when |
| outside lever is locked |
• Inside lever always operative
• ANSI/BHMA F88
• Deadlocking latch
• Both levers rigid at all times
• Latch by key either side
• Use only on rooms with more than one exit
• ANSI/BHMA F87
16 Classroom Security, Apartment, Exit, Privacy
10XG16
17 Utility, Asylum or Institutional
10XG17
• Deadlocking latch
• Latch by either lever
| • | Key in either lever locks or unlocks its own |
| lever only |
• Use only on rooms with more than one exit
• ANSI/BHMA F80
• Deadlocking latch
| • | Latch by either lever unless outside lever is |
| locked by key |
| • | Key in either lever locks or unlocks outside |
| lever |
• Inside lever always operable
| • | Locked indication on inside rose standard |
| with this function |
• ANSI/BHMA F110
30 Communicating
10XG30
• Deadlocking latch
• Latch by either lever
• Key in either lever locks or unlocks both levers
• ANSI/BHMA F91
26 Store or Storeroom
10XG26
38 Classroom Security Intruder
10XG38
• Deadlocking latch
• Latch by either lever unless outside lever is locked by push button inside or key outside
• Key outside locks or unlocks outside lever and also retracts latchbolt when locked
• When outside lever is locked by push button or key, it can be unlocked by key, rotating inside lever or closing door
• Modified ANSI/BHMA F90
53 Corridor, Dormitory
10XG53
• Deadlocking latch
| • | Latch by either lever unless outside lever is |
| locked by push button inside or key outside |
• � Rotating inside lever or closing door releases inside button only, but does not unlock the outside lever if locked by key
• � Key outside locks or unlocks outside lever and also retracts latchbolt when locked
• ANSI/BHMA F90
54 Corridor, Dormitory
10XG54
Single Cylinder Functions
60 Barrier Free Storeroom/Public Restroom
10XG60 • Deadlocking latch
• Latch by lever inside
• Key in outside lever unlocks outside lever to retract latch
• Key is retained in unlock mode
• When key is removed outside lever is locked
Shaded lever indicates it is rigid at all times.
1-800-727-5477 • www.sargentlock.com 9
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
• � Latch by either lever unless outside lever is locked by push button in inside lever
• � Turning inside lever or closing door releases button
• � Rotating thumbturn in outside lever unlocks the outside lever and releases the inside button
68 Hospital Privacy
10XU68
• For wood or custom hollow metal doors
• � Lever and rose both sides joined by two through-bolts
• Dummy latch plate
• Uses standard door prep template
94-2 Double Lever Pull
10XU94-2
• �Lever acts as a pull only, no operation
• Lever is rigid
| • | Requires special door preparation, see |
| template A8291 |
93 Single Lever Pull
10XU93
Non-Cylinder Functions
• Deadlocking latch
• Latch by inside lever
• Outside lever rigid at all times
• ANSI/BHMA F89
13 Exit
10XG13
• Latch by either lever
• ANSI/BHMA F75
15 Passage
10XU15
• Deadlocking latch
• Blank rose outside
• Latch by lever inside
• � Minimum clearance of 1-1/8" on single doors and 2-1/4" between double doors
15-3 Exit or Communicating
10XG15-3
• �Deadlocking latch
• Latch by either lever either side (passage) unless push button depressed and held by caretaker (detention side becomes rigid). Lock returns to passage mode upon release of push button.
• Push button automatically releases when caretaker releases push button.
• Both levers always free
64 Time Out Lock
10XG64
• Deadlocking latch
| • | Latch by either lever unless outside lever is |
| locked by push button in inside lever |
| • | Turning inside lever or closing door |
| releases button |
| • | Should not be used in rooms that have no |
| other entrance |
• ANSI/BHMA F77A
14 Patio or Privacy
10XG14
• �Latch by either lever unless outside lever is locked by push button in inside lever
• � Turning inside lever or closing door releases button
| • | Emergency button in outside lever unlocks, |
| with use of a blade screwdriver in outside lever | |
| and releases inside button |
• ANSI/BHMA F76A
65 Privacy/Bathroom
10XU65
Shaded lever indicates it is rigid at all times.
• �Lever and rose both sides joined by two through-bolts
• Levers act as a pulls only, no operation
• Levers are rigid
| • | Requires special door preparation, see |
| template A8291 |
94 Double Lever Pull
10XU94
1-800-727-5477 • www.sargentlock.com10
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Electromechanical Functions & Accessories
• Non-Contact Switch
• Bidirectional lever rotation
• Non-handed design
• Internal switch offers N/O & N/C
• Modular wire harness with ElectroLynx® 8-pin connector
• Available functions: 04, 05, 15, 37, 70 & 71
• 10G70: Power off, unlocks outside lever
• 10G71: Power off, locks outside lever
• Deadlocking latch
• Key retracts latch
• Inside lever always allows egress
| • | Voltage requirements: 12VDC or 24VDC |
| Regulated; always specify voltage |
• 250mA at 24VDC or 500mA at 12VDC
| • | Provided with ElectroLynx® 8-Pin |
| Connector |
70 Electromechanical (Fail Safe) 71 Electromechanical (Fail Secure)
10G70/10G71
RX- Monitoring of Inside Lever
Requirements for Electrical and Data Transfer
SARGENT Model No. Description 3521 12V - 1 AMP Power Supply
3541 12V - 3 AMP Power Supply
3551 12V - 4.5 AMP Power Supply
3571 12V - 6 AMP Power Supply
737 12V - 5 AMP Hour Battery Backup
12VDC & 24VDC Power Supplies:
SARGENT Model No. Description
3520 24V - 1 AMP Power Supply
3540 24V - 2 AMP Power Supply
3550 24V - 4 AMP Power Supply
3570 24V - 6 AMP Power Supply
738 24V - 5 AMP Hour Battery Backup
To answer the demand for “smart” electronic access control and locking solutions that require fast, easy, and cost-effective installation, ASSA ABLOY Group brands use the ElectroLynx® standardized plug-in connectors and color-coded wiring system.
With ElectroLynx, doorway components come pre-wired for easy hookup to the power source. Key to the system is the transfer device hinge that carries power from the frame to the locking hardware.
Features of ElectroLynx®:
| • | �� Makes it easy to bring power to the locking hardware |
| • | �� Wires have connectors that snap together, like plugging a |
telephone into a jack
To connect 10 Line Electrified Lock to the electronic access control system, the following items are required:
| • | �� 10 Line Electrified Lock |
| • | �� ASSA ABLOY Door Group pre-wired door, or ElectroLynx® retrofit |
cable (order from McKinney)
• �� Electronic transfer device (ElectroLynx® electronic transfer hinge or Electrical Power Transfer with standard hinge, from McKinney)
• �� ElectroLynx® cable from the hinge to above the ceiling (order from McKinney)
Information regarding cable selection, hinge requirements and order strings can be found in the McKinney Transfer Device Solutions catalog. Consult 800-810-WIRE (9473) with questions on application specifications and requirements.
McKinney QC8 ElectroLynx® hinges are recommended for Electrified 10 Line Applications
| • | � UL Class 2 Listed |
| • | �� Four 12V models and four 24V models available |
| • | �� Integral battery charging capability keeps sealed lead acid gel/ |
cell at full charge in case of line voltage failure (737-battery sold separately)
• � Fused line voltage input with one, four, or eight DC outputs (depending on model)
• �� �Each circuit can be individually turned on and off via a slide switch; the power status of each is shown by an LED.
• �� �In the event of a DC short the problem is confined to the zone of difficulty
• � Fire alarm interface standard
1-800-727-5477 • www.sargentlock.com 11
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Cylinders
Interchangeable Core^
Type Pins Standard Cylinder Hotel Cylinder Large Format Small Format
Conventional 6 C10X-1 C10X-2 6300 7300B
7 N/A N/A N/A 7P-7300B
Signature 6 10-C10X-1 N/A 10-6300 N/A
XC
6 11-C10X-1 N/A 11-6300 N/A
7 N/A N/A N/A 11-7P-7300B
Keso 12 F1-82-C10X-1 N/A N/A N/A
Degree® DG1 6 DG1-C10X-1 DG1-C10X-2 DG1-6300 N/A
Degree® DG2 6 DG2-C10X-1 N/A DG2-6300 N/A
Degree® DG3 6 DG3-C10X-1 N/A DG3-6300 N/A
All cylinders are supplied with 2 nickel silver change keys.
When cylinders are ordered keyed to 5 pin systems, the (6th) last chamber will be empty.
Cylinders are supplied 1-bitted unless specified keyed random or master keyed. For master keyed orders provide keying details as requested on SARGENT Keyed Order Lead Sheets, located in the price book or contact customer service.
To order cylinders separately, specify part number x keyway x finish (i.e. C10X-1 x LA x 15)
^Locks will be provided with the applicable tailpiece per the type interchangeable and/or removable core being used.
For example standard cores and XC cores require different tailpieces. When ordering complete locks, the appropriate option code must be specified in accordance to the permanent core being used. See pages 14-15 for cylinder options.
C10X-1
S RGENT
DG-6300
S RGENT
7P-7300B
• Finishes: 04, 15, BSP
Cylinders
Levers That Accept Cylinders/Cores from Other Manufacturers*
Cylinder Type Option Code Ordered with Lock
Available Levers
Tailpiece Packs (provided with lock)
Competitor Cylinder Compatibility
Fixed Core Schlage® 6-pin 30- All 10-3625 (std)
10-3626 (31-) Schlage® Conventional or Primus®
Yale® 6-pin YC- All 10-3639 (std) 10-3640 (31-)
1803-46L
Yale® 7-pin YC-7P- All 1803A-46L
Interchangeable Core SFIC 6- or 7-pin 70-, 72-, 73- All 10-3633 (std)
10-3634 (31-) All 6- or 7-pin small format interchangeable cores
Schlage® LFIC 6-pin SF- B, L, P 10-3627 (std) 10-3628 (31-)
All Schlage® 6-pin large format interchangeable cores
Yale® 6-pin LFIC YRC- L, P 10-1191 (std) 10-1192 (31-)
All Yale® 6-pin large format interchangeable cores
*SFIC cores are available through SARGENT, all other cylinders/cores not included and are provided by others.
Interchangeable Core Tailpiece Packs (replacement parts)
Used with: Type Std. Doors Thick Doors (31-) 10-6300
DGX-6300
LFIC Conventional LFIC Signature LFIC Degree®
10-3631 10-3632
11-6300 LFIC XC 10-3635 10-3636
7300B SFIC 6 Pin 10-3633 10-3634
7P-7300B 11-7P-7300B
SFIC 7 Pin
SFIC XC
10-3641 10-3642
Note: Tailpieces included with lock.
Cylinders with Competitive Keyways
Competitive Keyway Part Number Schlage® C SC-C10X-1
Schlage® E SE-C10X-1
All cylinders are 6-pin, 0-bitted and supplied with two brass key blanks. Cylinders include tail piece.
Refer to Cylinders and Components catalog for more information.
1-800-727-5477 • www.sargentlock.com12
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Latches
Plain/Unguarded Latch - 10U15, 10U65, 10U68:
Part No. Front Front Width Backset Throw
10-3187 Square Corner 1" (25mm) 2-3/8" (60mm) 1/2" (13mm)
10-2022 Square Corner 1-1/8" (29mm) 2-3/4" (70mm) 1/2" (13mm)
10-2054 Square Corner 1-1/8" (29mm) 3-3/4" (95mm) 1/2" (13mm)
10-2057 Square Corner 1-1/8" (29mm) 5" (127mm) 1/2" (13mm)
Deadlocking/Guarded Latch - All Other Functions:
Part No. Front Front Width Backset Throw
10-3186 Square Corner 1" (25mm) 2-3/8" (60mm) 1/2" (13mm)
10-2000 Square Corner 1-1/8" (29mm) 2-3/4" (70mm) 1/2" (13mm)
10-2053 Square Corner 1-1/8" (29mm) 3-3/4" (95mm) 1/2" (13mm)
10-2058 Square Corner 1-1/8" (29mm) 5" (127mm) 1/2" (13mm)
10-2634* Square Corner 1-1/8" (29mm) 2-3/4" (70mm) 3/4" (19mm)
When ordering latches separately, specify Part No. x Finish (e.g., 10-3186 x 32D)
Plain/Unguarded
Deadlocking/Guarded
Miscellaneous:
Part No. Description
10-2059 3-3/4" (95mm) Latch extension only
10-2060 5" (127mm) Latch extension only
• Finishes: 03, 04, 09, 10, 10B, 10BE, 10BL, 20D, 32D, BSP, WSP
Latches
* 04/26D finish only
1-800-727-5477 • www.sargentlock.com 13
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Strikes and Miscellaneous Parts
2-3/4" Curved Lip Strike (29- Option)
Strikes
• Finishes: 03, 04, 09, 10, 10B, 10BE, 10BL, 20D, 32, 32D, BSP, WSP
4-7/8" Curved Lip Strike (Standard)
• Used with ANSI 4-7/8" (124mm) strike (#808)
• To order with lock, specify option WBS
• To order separately, specify 77-1141
ANSI Wrought Strike Box
Part No. Description
10-3188 1-3/8" Adapter plate pack (set of 2)
C10X-3 Emergency release cylinder (65 function)
10-0043 Push pin tool
10-1224 Screw pack (standard)
10-1250 Screw pack (29- option)
82-3855 6 lobe bit pack 6 bits (Sizes – T8, T9, T10, T15, T20, T25, T27) Requires 9/32" driver
82-3856 Spanner bit pack 5 bits (Sizes – 6, 8, 10, 12, 14) Requires 1/4" driver
Miscellaneous Parts
1/4" (6mm)
1/64" (.40)
- 0+
1-1/4" (32mm)
3/32" (2mm)
3-3/8" (86mm)
4-7/8" (124mm)
4-1/8" (105mm)
1-1/4" (32mm)
For (2) No 12 Screws
Lip Only
5/8" (16mm)
1-1/4" (32mm)
1/4" (6mm) 3/32" (2mm)
Latch Center Strike Center
1-1/2" (38mm)
1-1/8" (29mm)
2-1/8" (54mm)
2-3/4" (70mm)
• Brass, bronze or stainless steel
• Conforms to ANSI standard
• � Furnished standard with curved lip 1-1/4" (32mm) from center of strike screw holes to end of lip
| • | � Lip lengths 1-1/8" (29mm), 1-1/4" (32mm), 1-3/8" (35mm), |
| 1-5/8" (42mm), 1-7/8" (48mm), 2-1/8" (54mm), 2-3/8" (60mm), | |
| 2-5/8" (66mm), 2-7/8" (73mm) and 3" (76mm) |
• 77-1141 Wrought strike box available separately
• To order strike separately, specify 808 strike x finish x lip length
• � Brass, bronze or stainless steel
| • | Furnished standard with 1-1/4" (32mm) curved lip from center of |
| strike screw holes to end of lip |
| • | � Lip lengths 1" (25mm), 1-1/4" (32mm) standard, 1-1/2" (38mm), |
| 1-3/4" (44mm), 2" (51mm) and 3" (76mm) |
• Plastic strike box AM-0044 included when 29- ordered with lockset
• To order strike separately, specify 800 strike x finish x lip length
1-800-727-5477 • www.sargentlock.com14
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Cylinder Options
Cylinder Options:
Conventional Cylinder — SARGENT® conventional cylinders supplied standard (nomenclature not required)
Degree Key System
DG1- SARGENT Degree key system level 1 (bump resistant with patented keys)
DG1-21- * Degree level 1 construction master keying
DG1-60- Degree level 1 removable disposable construction core
DG1-63- Degree level 1 removable core
DG1-64- Degree level 1 removable construction keyed LFIC
DG1-65-* Degree level 1 unassembled/uncombinated fixed core component cylinder (packed loose for field keying)
DG1-63-65- Degree level 1 unassembled/uncombinated removable core LFIC (packed loose for field keying)
DG2- * SARGENT Degree key system level 2 (geographically exclusive; bump and pick resistant)
DG2-21- * Degree level 2 construction master keying
DG2-60-* Degree level 2 removable disposable construction core
DG2-63-* Degree level 2 removable core
DG2-64-* Degree level 2 removable construction keyed LFIC
DG2-65-* Degree level 2 unassembled/uncombinated fixed core component cylinder (packed loose for field keying)
DG2-63-65-* Degree level 2 unassembled/uncombinated removable core LFIC (packed loose for field keying)
DG3-* SARGENT Degree key system level 3 (geographically exclusive; UL437 certified; bump and pick resistant)
DG3-21- * Degree level 3 construction master keying
DG3-60-* Degree level 3 removable disposable construction core
DG3-63-* Degree level 3 removable core
DG3-64-* Degree level 3 removable construction keyed LFIC
Signature Key System 10-* SARGENT Signature key system
10-21-* SARGENT Signature construction key system (lost ball)
Signature:
Large Format Interchangeable Core (Removable Core)
10-63-* SARGENT Signature LFIC (removable core) cylinder
XC- Key System 11-* XC Key System
11-21-* XC- Construction Key System (Lost Ball)
XC- Large Format Interchangeable Core (Removable Core)
11-60-* Lock to accept XC-LFIC (removable core) and provided with disposable plastic core; XC-LFIC permanent core ordered separately
11-63-* Lock provided with XC-LFIC (removable core); Includes master keying, grand master keying
11-64-* Lock to accept XC-LFIC (removable core) and provided with keyed construction core; XC-LFIC permanent core ordered separately.
XC- Small Format Interchangeable Cores
11-70-7P-* Lock to accept XC-SFIC (7-pin, removable core) and provided with disposable plastic core; XC-SFIC permanent core ordered separately
11-72-7P-* Lock to accept XC-SFIC (7-pin, removable core) and provided with keyed construction core; XC-SFIC permanent core ordered separately
11-73-7P-* Lock provided with XC-SFIC (7-pin, removable core); Includes master keying, grand master keying
11-65-73-7P-* Lock provided with uncombinated SFIC (7-pin, removable core); Packed loose
Construction Key Systems
21-* SARGENT Lost Ball Construction Keying for Conventional, XC and Signature Series (N/A with 63- or 73-)
22-* SARGENT Construction Split Key System for Conventional Cylinders (existing systems only) (N/A with 10-, 11-, 63- or 73-)
Note: Cylinder Options continued on the following page
* Options not available with 10XG50
1-800-727-5477 • www.sargentlock.com 15
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Cylinder Options
Cylinder Options:
Large Format Interchangeable Core (Removable Core)
60-* Lock to accept LFIC (removable core) and provided with disposable plastic core; LFIC permanent core ordered separately
63-* Lock provided with LFIC (Removable Core) Cylinder — (Includes masterkeying, grand masterkeying)
64-* Lock to accept LFIC (removable core) and provided with keyed construction core; LFIC permanent core ordered separately
Small Format Interchangeable Cores
70-* Lock to accept SFIC (6 or 7-pin, removable core) and provided with disposable plastic core; SFIC permanent core ordered separately
72-* Lock to accept SFIC (6 or 7-pin, removable core) and provided with keyed construction core; SFIC permanent core ordered separately
73-* Lock provided with SFIC (6-pin, removable core); Includes master keying, grand master keying
73-7P-* Lock provided with SFIC (7-pin, removable core); Includes master keying, grand master keying
65-73-* Lock provided with uncombinated SFIC (6-pin, removable core); Packed loose
65-73-7P-* Lock provided with uncombinated SFIC (7-pin, removable core); Packed loose
Keso & Keso F1
80-* Lock to accept Keso and Keso F1 cylinders — no cylinders provided (L,B,P levers only)
82-* Lock provided with SARGENT Keso Security Cylinder (L,B,P levers only)
F1-82-* Lock provided with SARGENT Keso F1 Security Cylinder (Patented) (L,B,P levers only)
Bump Resistant BR- Bump Resistant Cylinder (available with Conventional & Conventional XC Cylinders only)
Keyed Different KD- Cylinders provided keyed differently/random
Less Cylinder LC- Lock supplied less Cylinder
Schlage®
Keyways SC-* Schlage® C keyway cylinder, 0 bitted
SE-* Schlage® E keyway cylinder, 0 bitted
Accepts Schlage® Cylinders
30-* Lever to accept Schlage® fixed core cylinder - cylinder is not provided (all designs)
SF-* L, B, or P lever to accept Schlage® large format interchangeable core (supplied less core, tailpiece included)
Accepts Yale® Cylinders/Cores
YC- Lever to accept Yale® 6-pin fixed core cylinder - less cylinder, tailpiece provided (all designs)
YC-7P- Lever to accept Yale® 7-pin fixed core cylinder - less cylinder, tailpiece provided (all designs)
YRC- L or P Lever to accept Yale® 6-pin large format interchangeable core (supplied less core, but with tailpiece needed)
* Options not available with 10XG50 Note:
• 10X Line locks will be provided with the applicable tailpiece per the type interchangeable and/or removable core being used. For example standard cores and XC cores require different tailpieces. Appropriate option codes must be specified in accordance to the permanent core being used.
1-800-727-5477 • www.sargentlock.com16
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Mechanical Options
Mechanical Options:
Thin Doors 1- Adapter plates for 1-3/8" thick doors (2-3/4" backset latch with 1-1/8" front provided unless 20- option for 2-3/8" backset also specified)
Backset Options
20- 2-3/8" backset latch with 1" front
23- 3-3/4" backset x 2-1/4" x 1-1/8" front
25- 5" backset x 2-1/4" x 1-1/8" front
Strike 29- Strike #800. Lip length 1-1/4". Lip lengths 1" to 2" in 1/4" increments only.
Thick Doors 31- For 2" to 2-1/4" thick doors, centered in door prep, no paneling. Consult factory for other door thicknesses available by special application.
Security Fasteners 36- Six lobe security head screws
37- Spanner head screws
3/4" Throw 41- 3/4" throw latchbolt x 2-3/4" backset
Lead Lining 74- Lead provided between lockbody and spring cartridge
Tactile Warning Options
75- Tactile warning - handicap warning milled on backside of inside lever (L, B, P levers only)
76- Tactile warning - handicap warning milled on backside of outside lever (L, B, P levers only)
77- Tactile warning - handicap warning milled on backside of both levers (L, B, P levers only)
85- Tactile warning - abrasive coating finish on inside lever
86- Tactile warning - abrasive coating finish on outside lever
87- Tactile warning - abrasive coating finish on both levers
Freewheeling Trim FW- Freewheeling locking levers
Finish Protection SG- MicroShield® antimicrobial clear powder coat (only available with 15 and 26D finishes)
CPC- Clear Powder Coat over 26D – 10XG05 x LL x 26D x CPC
Request to Exit RX- Request to exit - monitors inside lever rotation (available with functions: 04, 05, 15, 37, 70 & 71)
Box Strike WBS- Wrought box strike
1-800-727-5477 • www.sargentlock.com 17
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Finishes, Packaging
SARGENT # Descriptions ANSI/BHMA 03 Polished brass, clear coated 605 04 Satin brass, clear coated 606 09 Polished bronze, clear coated 611 10 Satin bronze, clear coated 612 10B Oxidized bronze, oil rubbed 613 10BE Dark Oxidized Satin Bronze - equivalent 613E 10BL Oxidized satin, bronze, clear coated 613L 14 Polished nickel, clear coated 618 15 Satin nickel, clear coated 619 20D Statuary dark bronze, clear coated 624 26 Polished chrome 625 26D Satin chrome 626 BSP Black suede powder coat BSP WSP White suede powder coat WSP SG- Option �MicroShield® antimicrobial clear powder coat
(only available with 15 and 26D finishes) Zinc levers are plated to match ANSI/BHMA finish.
Custom colors available, consult factory.
Split finishes:
| - | Specify outside finish first i.e. 10XG05 x LL x 26D x 03 x RH |
| - | Handing must be specified |
| - | Strike and latch front will match the following: |
| RH & LH = inside finish | |
| RHR & LHR = outside finish |
Packaging
10XG05 x LL
4.8 lbs/box (2.2 kg/box)
8 boxes/case
Lock Finish Cylinder/Core*
03, 04, 09, 10, 10B, 10BE, 10BL, 20D 04
14, 15, 26, 26D, WSP 15
BSP BSP
*Finish when cylinder provided with lock
1-800-727-5477 • www.sargentlock.com18
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
How to Order
How to Order
How to Specify Handing
5 DG1- 10XG05 G L RH 15 Door 3
Quantity Options* Lock & Function Rose Lever Hand Finish Additional
Information
Available Options Pg 14-16
Available Functions
Pg 7-9
Available Roses G & L
Available Levers Pg 6
RH,
LH,
RHR,
LHR
Available Finishes
Pg 17
Such as Item, Heading Number, Door Number, Cylinder Keying Details (i.e KD, Keyset)
* Multiple options may be selected
Inside
Outside
Inside
Outside
1-800-727-5477 • www.sargentlock.com 19
1 � Co p yr ig ht
1, S ar g en t M an uf ac tu rin g C o m p an y, a n A
SS
A
A B
LO
Y
G ro up c o m p an y.
A ll rig ht s re se rv ed
Re p ro d uc tio n in w ho le o r i n p ar t w ith o ut th e ex p re ss w rit te n p er m is si o n o f S ar g en t M an uf ac tu rin g
C o m p an y is p ro hi b ite d
Architectural Specifications
A. � Locks shall be 10X Line as manufactured by Sargent Manufacturing Company, New Haven, CT.
B. Locks shall be ANSI/BHMA Certified Products Directory (CPD) listed.
1. A156.2, Series 4000, Grade 1
2. A156.41
C.� Locks shall exceed the requirements of ANSI/BHMA A156.2 Series 4000, Grade 1 with all standard trims, as follows:
1. Cycle Test: Exceeds ANSI/BHMA A156.2 Grade 1 requirements with no lever sag
2. Abusive Locked Lever Torque: Exceeds 3,100 in-lb with no entry while maintaining egress (2.6 times ANSI/BHMA A156.2 requirements)
3. Offset Lever Pull: Exceeds 1,600 lbs with no entry (8 times ANSI/BHMA A156.2 requirements)
| 4. | Latch Retraction with Preload: Exceeds 100lb preload while maintaining ANSI/BHMA requirements for operation in warped doors |
| (2 times ANSI/BHMA A156.2 requirements) |
5. Vertical Impact: Exceeds 100 vertical impacts (20 times ANSI/BHMA A156.2 requirements)
D. � Locks shall comply with UL 10C positive pressure requirements.
E. � Locks required for fire doors shall be listed by Underwriters Laboratories for ratings of 3 hours (A label) and less, for doors up to 4'0" (1.2m) x 10'0" (3.0m) and pairs of doors 8'0" (2.4m) x 10'0" (3.0m)
F. Locks shall have a push/turn button adjustable for door thickness without disassembly.
G. Locks shall have a chassis design that supports all cylinder formats (except Keso) allowing flexibility for changing from fixed core to inter-changeable core cylinders.
H. Locks shall be non-handed with bi-directional lever operation.
I. Lock levers shall be made of solid material.
J. Lock shall be available in a minimum of seven different lever designs.
K. � Locks shall have a 2-3/4" (70mm) standard backset.
L. � Strikes shall be non-handed with a curved lip. Provide wrought boxes with strikes.
M. �Locks shall have brass 6-pin cylinder standard.
1. Provide two nickel silver keys with each lock.
N. Locks shall have approximately 45 degrees of lever rotation in order to fully retract latch.
�O. Locks shall have a ten-year limited warranty.
Suggested Architectural Specifications - 2.0 Cylindrical Locks
90890 10/21
Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets.
Copyright © 2021, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. Patent pending and/or patent www.assaabloydss.com/patents.
SARGENT Manufacturing Company 100 Sargent Drive New Haven, CT 06511 USA 800-727-5477 www.sargentlock.com
File details come from the government source that posted it. Updated .